Chia VAP, See Toh YL, Quek HC, Pokharkar Y, Yap AU, Yu N. Comparative clinical evaluation of removable partial denture frameworks fabricated traditionally or with selective laser melting: A randomized controlled trial. J Prosthet Dent 2024; 131:42-49. [PMID: 35260255 DOI: 10.1016/j.prosdent.2021.12.021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2021] [Revised: 12/15/2021] [Accepted: 12/15/2021] [Indexed: 10/18/2022]
Abstract
STATEMENT OF PROBLEM The clinical efficacy of selective laser melting (SLM) for fabricating removable partial dentures (RPDs) is not well established. PURPOSE The purpose of this clinical study was to compare the performance of SLM-fabricated frameworks with that of those fabricated via traditional lost wax casting. MATERIAL AND METHODS A double-blind, randomized, crossover design was used to compare cobalt chromium partial denture frameworks (n=29) fabricated by using SLM or traditional methods. The time taken for adjustments and the clinical fit and stability of the adjusted frameworks were appraised. The accuracy of the frameworks was assessed by measuring the space between the occlusal rest seat and the corresponding rest seat. Statistical comparisons between the 2 frameworks were carried out by using a linear mixed-effect model for repeated measurements (α=.05). RESULTS Frameworks fabricated by using both SLM and traditional techniques had an acceptable fit based on subjective clinical evaluation. The overall mean ±standard deviation space between the occlusal rest and rest seat for SLM frameworks (273.7 ±44.5 μm) was comparable with that of traditional frameworks (242.2 ±44.5 μm). The clinical fit adjustment time, 7.76 ±6.43 minutes for SLM and 5.49 ±6.39 minutes for traditionally fabricated frameworks, was statistically similar (P=.067). CONCLUSIONS Dentures fabricated via SLM and traditional techniques had comparable accuracy of fit and clinical fitting time.
Collapse
Affiliation(s)
- Vanessa Ai Ping Chia
- Associate Consultant, Department of Restorative Dentistry and National Dental Research Institute Singapore, National Dental Centre Singapore, Singapore Health Services, Singapore
| | - Yoong Liang See Toh
- Senior Consultant, Department of Restorative Dentistry and National Dental Research Institute Singapore, National Dental Centre Singapore, Singapore Health Services, Singapore
| | - Heng Chuan Quek
- Senior Consultant, Department of Restorative Dentistry and National Dental Research Institute Singapore, National Dental Centre Singapore, Singapore Health Services, Singapore
| | - Yogesh Pokharkar
- Senior Statistician, Singapore Clinical Research Institute, Singapore; Senior Consultant, Department of Dentistry, Ng Teng Fong General Hospital, National University Health System, Singapore
| | - Adrian Ujin Yap
- Adjunct/Clinical Associate Professor, National Dental Research Institute Singapore, National Dental Centre Singapore and Duke-NUS Medical School, Singapore Health Services, Singapore
| | - Na Yu
- Adjunct Assistant Professor, National Dental Research Institute Singapore, National Dental Centre Singapore and Duke-NUS Medical School, Singapore Health Services, Singapore.
| |
Collapse
|
2
|
Moraru E, Stoica AM, Donțu O, Cănănău S, Stoica NA, Constantin V, Cioboată DD, Bădiță-Voicu LL. Mechanical and Surface Characteristics of Selective Laser Melting-Manufactured Dental Prostheses in Different Processing Stages. MATERIALS (BASEL, SWITZERLAND) 2023; 16:6141. [PMID: 37763418 PMCID: PMC10533055 DOI: 10.3390/ma16186141] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/11/2023] [Revised: 09/05/2023] [Accepted: 09/07/2023] [Indexed: 09/29/2023]
Abstract
Due to the expansion of the use of powder bed fusion metal additive technologies in the medical field, especially for the realization of dental prostheses, in this paper, the authors propose a comparative experimental study of the mechanical characteristics and the state of their microscale surfaces. The comparison was made from material considerations starting from two dental alloys commonly used to realize dental prostheses: Ni-Cr and Co-Cr, but also technologies for obtaining selective laser melting (SLM) and conventional casting. In addition, to compare the performances with the classical casting technology, for the dental prostheses obtained through SLM, the post-processing stage in which they are in a preliminary finishing and polished state was considered. Therefore, for the determination of important mechanical characteristics and the comparative study of dental prostheses, the indentation test was used, after which the hardness, penetration depths (maximum, permanent, and contact depth), contact stiffness, and contact surface were established, and for the determination of the microtopography of the surfaces, atomic force microscopy (AFM) was used, obtaining the local areal roughness parameters at the miniaturized scale-surface average roughness, root-mean-square roughness (RMS), and peak-to-peak values. Following the research carried out, several interesting conclusions were drawn, and the superiority of the SLM technology over the classic casting method for the production of dental prostheses in terms of some mechanical properties was highlighted. At the same time, the degree of finishing of dental prostheses made by SLM has a significant impact on the mechanical characteristics and especially the local roughness parameters on a miniaturized scale, and if we consider the same degree of finishing, no major differences are observed in the roughness parameters of the surfaces of the prostheses produced by different technologies.
Collapse
Affiliation(s)
- Edgar Moraru
- Faculty of Mechanical Engineering and Mechatronics, National University of Science and Technology Politehnica Bucharest, 313 Splaiul Independentei, 060042 Bucharest, Romania; (E.M.); (O.D.); (S.C.); (N.-A.S.); (V.C.)
| | - Alina-Maria Stoica
- Faculty of Mechanical Engineering and Mechatronics, National University of Science and Technology Politehnica Bucharest, 313 Splaiul Independentei, 060042 Bucharest, Romania; (E.M.); (O.D.); (S.C.); (N.-A.S.); (V.C.)
| | - Octavian Donțu
- Faculty of Mechanical Engineering and Mechatronics, National University of Science and Technology Politehnica Bucharest, 313 Splaiul Independentei, 060042 Bucharest, Romania; (E.M.); (O.D.); (S.C.); (N.-A.S.); (V.C.)
| | - Sorin Cănănău
- Faculty of Mechanical Engineering and Mechatronics, National University of Science and Technology Politehnica Bucharest, 313 Splaiul Independentei, 060042 Bucharest, Romania; (E.M.); (O.D.); (S.C.); (N.-A.S.); (V.C.)
| | - Nicolae-Alexandru Stoica
- Faculty of Mechanical Engineering and Mechatronics, National University of Science and Technology Politehnica Bucharest, 313 Splaiul Independentei, 060042 Bucharest, Romania; (E.M.); (O.D.); (S.C.); (N.-A.S.); (V.C.)
| | - Victor Constantin
- Faculty of Mechanical Engineering and Mechatronics, National University of Science and Technology Politehnica Bucharest, 313 Splaiul Independentei, 060042 Bucharest, Romania; (E.M.); (O.D.); (S.C.); (N.-A.S.); (V.C.)
| | - Daniela-Doina Cioboată
- The National Institute of Research and Development in Mechatronics and Measurement Technique, 6-8 Soseaua Pantelimon, 021631 Bucharest, Romania; (D.-D.C.); (L.-L.B.-V.)
| | - Liliana-Laura Bădiță-Voicu
- The National Institute of Research and Development in Mechatronics and Measurement Technique, 6-8 Soseaua Pantelimon, 021631 Bucharest, Romania; (D.-D.C.); (L.-L.B.-V.)
| |
Collapse
|
3
|
Kassapidou M, Stenport VF, Johansson CB, Syverud M, Hammarström Johansson P, Börjesson J, Hjalmarsson L. Cobalt chromium alloys in fixed prosthodontics: Investigations of mechanical properties and microstructure. J Prosthet Dent 2023; 130:255.e1-255.e10. [PMID: 37355405 DOI: 10.1016/j.prosdent.2023.05.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2022] [Revised: 05/10/2023] [Accepted: 05/11/2023] [Indexed: 06/26/2023]
Abstract
STATEMENT OF PROBLEM Cobalt chromium (Co-Cr) alloys possess beneficial mechanical properties because alloys, even in thin sections, can resist high mastication forces and exhibit an acceptable bond to the surface porcelain layer. Traditional manufacturing techniques of Co-Cr alloys such as casting have been replaced with newer fabrication techniques, such as milling, laser melting, and presintered milling. Despite scarce documentation, these new manufacturing techniques are being used to fabricate dental and implant constructions. PURPOSE This in vitro study investigates the hardness, yield strength, elastic modulus, and microstructure of the most commonly used Co-Cr alloys for fixed prosthodontics based on manufacturing technique. In addition, this study investigates the effect of heat treatment on the mechanical properties and microstructure of these materials. MATERIAL AND METHODS Five Co-Cr alloys were included (dumbbell and rectangular shaped) based on four manufacturing techniques: cast, milled, laser melted, and presintered milled. Commercially pure titanium grade 4 and titanium-6 aluminum-4 vanadium ELI (extra low interstitial) were included for comparison, and yield strength and elongation after fracture were evaluated. The specimens were tested for hardness using the Vickers test and for elastic modulus using a nondestructive impulse excitation technique. The microstructure of selected specimens was analyzed using focused ion beam-scanning electron microscopy (FIB-SEM) and energy dispersive X-ray spectroscopy (EDS). RESULTS The mechanical properties depend on the manufacturing technique used; the laser-melted and presintered Co-Cr specimens demonstrated the highest mechanical properties, followed by the milled and cast groups. Both the laser-melted and the presintered milled Co-Cr specimens showed smaller grain size compared with the cast and milled Co-Cr specimens. The titanium-6 aluminum-4 vanadium ELI demonstrated higher hardness and yield strength compared to commercially pure titanium grade 4. No major differences were observed for the selected materials regarding the mechanical properties and microstructural appearance after heat treatment. CONCLUSIONS The laser melting and presintered milling techniques produced higher mechanical properties compared with the cast and milled Co-Cr. These findings were confirmed through microstructural analysis with respect to the grain size, precipitation, and number of pores.
Collapse
Affiliation(s)
- Maria Kassapidou
- Researcher, Department of Prosthodontics/Dental Materials Science, Institute of Odontology, The Sahlgrenska Academy, University of Gothenburg, Göteborg, Sweden; Researcher, Department of Prosthetic Dentistry, Institute for Postgraduate Dental Education, Jönköping, Sweden.
| | - Victoria Franke Stenport
- Professor, Department of Prosthodontics/Dental Materials Science, Institute of Odontology, The Sahlgrenska Academy, University of Gothenburg, Göteborg, Sweden
| | - Carina B Johansson
- Professor Emerita, Department of Prosthodontics/Dental Materials Science, Institute of Odontology, The Sahlgrenska Academy, University of Gothenburg, Göteborg, Sweden
| | - Morten Syverud
- Researcher, NIOM, Nordic Institute of Dental Materials, Oslo, Norway
| | - Petra Hammarström Johansson
- Researcher, Department of Prosthodontics/Dental Materials Science, Institute of Odontology, The Sahlgrenska Academy, University of Gothenburg, Göteborg, Sweden
| | - Johan Börjesson
- Researcher, Department of Materials and Manufacturing, School of Engineering, Jönköping University, Jönköping, Sweden
| | - Lars Hjalmarsson
- Lecturer, Department of Prosthodontics/Dental Materials Science, Institute of Odontology, The Sahlgrenska Academy, University of Gothenburg, Göteborg, Sweden; Researcher, Centre for Clinical Research Sörmland, Uppsala University, Eskilstuna, Sweden
| |
Collapse
|
4
|
Celik HK, Koc S, Kustarci A, Caglayan N, Rennie AE. The state of additive manufacturing in dental research - A systematic scoping review of 2012-2022. Heliyon 2023; 9:e17462. [PMID: 37484349 PMCID: PMC10361388 DOI: 10.1016/j.heliyon.2023.e17462] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2022] [Revised: 06/08/2023] [Accepted: 06/19/2023] [Indexed: 07/25/2023] Open
Abstract
Background/purpose Additive manufacturing (AM), also known as 3D printing, has the potential to transform the industry. While there have been advancements in using AM for dental restorations, there is still a need for further research to develop functional biomedical and dental materials. It's crucial to understand the current status of AM technology and research trends to advance dental research in this field. The aim of this study is to reveal the current status of international scientific publications in the field of dental research related to AM technologies. Materials and methods In this study, a systematic scoping review was conducted using appropriate keywords within the scope of international scientific publishing databases (PubMed and Web of Science). The review included related clinical and laboratory research, including both human and animal studies, case reports, review articles, and questionnaire studies. A total of 187 research studies were evaluated for quantitative synthesis in this review. Results The findings highlighted a rising trend in research numbers over the years (From 2012 to 2022). The most publications were produced in 2020 and 2021, with annual percentage increases of 25.7% and 26.2%, respectively. The majority of AM-related publications in dentistry research originate from Korea. The pioneer dental sub-fields with the ost publications in its category are prosthodontics and implantology, respectively. Conclusion The final review result clearly stated an expectation for the future that the research in dentistry would concentrate on AM technologies in order to increase the new product and process development in dental materials, tools, implants and new generation modelling strategy related to AM. The results of this work can be used as indicators of trends related to AM research in dentistry and/or as prospects for future publication expectations in this field.
Collapse
Affiliation(s)
- H. Kursat Celik
- Dept. of Agr. Machinery and Technology Engineering, Akdeniz University, Antalya, 07070, Turkey
| | - Simay Koc
- Dept. of Endodontics, Fac. of Dentistry, Akdeniz University, Antalya, Turkey
| | - Alper Kustarci
- Dept. of Endodontics, Fac. of Dentistry, Akdeniz University, Antalya, Turkey
| | - Nuri Caglayan
- Dept. of Mechatronics, Fac. of Engineering, Akdeniz University, Antalya, Turkey
| | | |
Collapse
|
5
|
Cai H, Xu X, Lu X, Zhao M, Jia Q, Jiang HB, Kwon JS. Dental Materials Applied to 3D and 4D Printing Technologies: A Review. Polymers (Basel) 2023; 15:polym15102405. [PMID: 37242980 DOI: 10.3390/polym15102405] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2023] [Revised: 05/09/2023] [Accepted: 05/17/2023] [Indexed: 05/28/2023] Open
Abstract
As computer-aided design and computer-aided manufacturing (CAD/CAM) technologies have matured, three-dimensional (3D) printing materials suitable for dentistry have attracted considerable research interest, owing to their high efficiency and low cost for clinical treatment. Three-dimensional printing technology, also known as additive manufacturing, has developed rapidly over the last forty years, with gradual application in various fields from industry to dental sciences. Four-dimensional (4D) printing, defined as the fabrication of complex spontaneous structures that change over time in response to external stimuli in expected ways, includes the increasingly popular bioprinting. Existing 3D printing materials have varied characteristics and scopes of application; therefore, categorization is required. This review aims to classify, summarize, and discuss dental materials for 3D printing and 4D printing from a clinical perspective. Based on these, this review describes four major materials, i.e., polymers, metals, ceramics, and biomaterials. The manufacturing process of 3D printing and 4D printing materials, their characteristics, applicable printing technologies, and clinical application scope are described in detail. Furthermore, the development of composite materials for 3D printing is the main focus of future research, as combining multiple materials can improve the materials' properties. Updates in material sciences play important roles in dentistry; hence, the emergence of newer materials are expected to promote further innovations in dentistry.
Collapse
Affiliation(s)
- HongXin Cai
- Department and Research Institute of Dental Biomaterials and Bioengineering, Yonsei University College of Dentistry, Seoul 03722, Republic of Korea
| | - Xiaotong Xu
- The CONVERSATIONALIST Club, School of Stomatology, Shandong First Medical University, Jinan 250117, China
| | - Xinyue Lu
- The CONVERSATIONALIST Club, School of Stomatology, Shandong First Medical University, Jinan 250117, China
| | - Menghua Zhao
- The CONVERSATIONALIST Club, School of Stomatology, Shandong First Medical University, Jinan 250117, China
| | - Qi Jia
- The CONVERSATIONALIST Club, School of Stomatology, Shandong First Medical University, Jinan 250117, China
| | - Heng-Bo Jiang
- The CONVERSATIONALIST Club, School of Stomatology, Shandong First Medical University, Jinan 250117, China
| | - Jae-Sung Kwon
- Department and Research Institute of Dental Biomaterials and Bioengineering, Yonsei University College of Dentistry, Seoul 03722, Republic of Korea
| |
Collapse
|
6
|
Stamenković D, Popović M, Rudolf R, Zrilić M, Raić K, Đuričić KO, Stamenković D. Comparative Study of the Microstructure and Properties of Cast-Fabricated and 3D-Printed Laser-Sintered Co-Cr Alloys for Removable Partial Denture Frameworks. MATERIALS (BASEL, SWITZERLAND) 2023; 16:3267. [PMID: 37110103 PMCID: PMC10145643 DOI: 10.3390/ma16083267] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/29/2023] [Revised: 04/16/2023] [Accepted: 04/19/2023] [Indexed: 06/19/2023]
Abstract
Since additive technologies in dentistry are gradually replacing metal casting technology, it is necessary to evaluate new dental constructions intended for the development of removable partial denture frameworks. The aim of this research was to evaluate the microstructure and mechanical properties of 3D-printed, laser-melted and -sintered Co-Cr alloys, and perform a comparative study with Co-Cr castings for the same dental purposes. The experiments were divided into two groups. The first group consisted of samples produced by conventional casting of the Co-Cr alloy. The second group consisted of 3D-printed, laser-melted and -sintered specimens produced from a Co-Cr alloy powder divided into three subgroups, depending on the technological parameters chosen for manufacturing (angle, location and heat treatment). Examination of the microstructure was carried out by classical metallographic sample preparation, using optical microscopy and scanning electron microscopy with energy dispersive X-ray spectroscopy (EDX) analysis. A structural phase analysis was also performed by XRD. The mechanical properties were determined using a standard tensile test. The microstructure observation showed a dendritic character in the case of castings, while in the case of 3D-printed, laser-melted and -sintered Co-Cr alloys, the microstructure was typical for additive technologies. The XRD phase analysis confirmed the presence of Co-Cr phases (ε and γ). The results of the tensile test showed remarkably higher yield and tensile strength values and slightly lower elongation of the 3D-printed, laser-melted and -sintered samples than those produced by conventional casting.
Collapse
Affiliation(s)
| | - Miljana Popović
- Faculty of Technology and Metallurgy, University of Belgrade, 11120 Belgrade, Serbia; (M.P.); (M.Z.); (K.R.)
| | - Rebeka Rudolf
- Faculty of Mechanical Engineering, University of Maribor, 2000 Maribor, Slovenia
| | - Milorad Zrilić
- Faculty of Technology and Metallurgy, University of Belgrade, 11120 Belgrade, Serbia; (M.P.); (M.Z.); (K.R.)
| | - Karlo Raić
- Faculty of Technology and Metallurgy, University of Belgrade, 11120 Belgrade, Serbia; (M.P.); (M.Z.); (K.R.)
| | | | | |
Collapse
|
7
|
Vasoglou G, Lyros I, Patatou A, Vasoglou M. Orthodontic Treatment of Palatally Impacted Maxillary Canines with the Use of a Digitally Designed and 3D-Printed Metal Device. Dent J (Basel) 2023; 11:dj11040102. [PMID: 37185480 PMCID: PMC10137553 DOI: 10.3390/dj11040102] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2023] [Revised: 03/21/2023] [Accepted: 04/06/2023] [Indexed: 05/17/2023] Open
Abstract
The purpose of this article is to present a computer designed and 3D-printed metal device, which was used for the surgical exposure and orthodontic treatment of maxillary palatally impacted canines. In two cases which presented a palatally impacted canine, a Cone-Beam Computed Tomography (CBCT) was acquired and an intraoral scanning was performed, to determine the exact location of the canine. Based on a digital model, a device leaning on the teeth and mucosa was designed to serve as a guiding tool for the oral surgeon to expose the crown of the canine and help the orthodontist to provide proper traction. The device was then 3D-printed in biocompatible dental alloy and placed in the patients' mouth. After the surgical exposure of the canine's crown in both cases, a gold chain apparatus was bonded on and it was mounted on the metal projection of the device through an elastic chain. Within 3 months of traction, the crown of the canines appeared in the patients' palate to the exact location that was predicted and guided. A 3D-designed and manufactured metal device, with information acquired by CBCT and intraoral scanning, can be used for the exposure and traction of palatally impacted canines.
Collapse
Affiliation(s)
| | - Ioannis Lyros
- Department of Orthodontics, School of Dentistry, National and Kapodistrian University of Athens, 11527 Athens, Greece
| | | | - Michail Vasoglou
- Private Orthodontic Practice, 17676 Athens, Greece
- Department of Orthodontics, School of Dentistry, National and Kapodistrian University of Athens, 11527 Athens, Greece
| |
Collapse
|
8
|
Saha S, Roy S. Metallic Dental Implants Wear Mechanisms, Materials, and Manufacturing Processes: A Literature Review. MATERIALS (BASEL, SWITZERLAND) 2022; 16:ma16010161. [PMID: 36614500 PMCID: PMC9821388 DOI: 10.3390/ma16010161] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/06/2022] [Revised: 11/29/2022] [Accepted: 12/13/2022] [Indexed: 06/12/2023]
Abstract
OBJECTIVES From the treatment of damaged teeth to replacing missing teeth, dental biomaterials cover the scientific interest of many fields. Dental biomaterials are one of the implants whose effective life depends vastly on their material and manufacturing techniques. The purpose of this review is to summarize the important aspects for metallic dental implants from biomedical, mechanical and materials science perspectives. The review article will focus on five major aspects as mentioned below. Tooth anatomy: Maximizing the implant performance depends on proper understanding of human tooth anatomy and the failure behavior of the implants. Major parts from tooth anatomy including saliva characteristics are explored in this section. Wear mechanisms: The prominent wear mechanisms having a high impact on dental wear are abrasive, adhesive, fatigue and corrosion wear. To imitate the physiological working condition of dental implants, reports on the broad range of mastication force and various composition of artificial saliva have been included in this section, which can affect the tribo-corrosion behavior of dental implants. Dental implants classifications: The review paper includes a dedicated discussion on major dental implants types and their details for better understanding their applicability and characteristics. Implant materials: As of today, the most established dental implant materials are SS316L, cobalt chrome alloy and titanium. Detailed discussion on their material properties, microstructures, phase transformations and chemical compositions have been discussed here. Manufacturing techniques: In terms of different production methods, the lost wax casting method as traditional manufacturing is considered. Selective Laser Melting (SLM) and Directed Energy Deposition (DED) as additive manufacturing techniques (AM) have been discussed. For AM, the relationships between process-property-performance details have been explored briefly. The effectiveness of different manufacturing techniques was compared based on porosity distribution, mechanical and biomechanical properties. SUMMARY Despite having substantial research available on dental implants, there is a lack of systematic reviews to present a holistic viewpoint combining state-of-the-art from biomedical, mechanical, materials science and manufacturing perspectives. This review article attempts to combine a wide variety of analyzing approaches from those interdisciplinary fields to deliver deeper insights to researchers both in academia and industry to develop next-generation dental implants.
Collapse
|
9
|
Kocak EF, Ekren O, Ucar Y. Effect of Internal Design Modification on the Mechanical Properties of Laser Sintered Cobalt-Chromium Multi-Unit Metal-Ceramic Frameworks. J Prosthodont 2022; 31:766-770. [PMID: 35246899 DOI: 10.1111/jopr.13501] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2021] [Accepted: 03/01/2022] [Indexed: 01/04/2023] Open
Abstract
PURPOSE The purpose of the study was to assess the effect of internal design modifications on the mechanical properties of multi-unit Cobalt-Chromium (Co-Cr) metal-ceramic frameworks manufactured by direct metal laser sintering. MATERIAL AND METHODS Four-unit fixed partial denture metal-ceramic frameworks were digitally designed on a metal die model using 3D software. A total of 30 specimens were prepared using Co-Cr alloy powder with direct metal laser sintering (n = 10). The control group specimens were solid where the inside of the specimens was completely full. For the test groups, the internal design of the framework was modified. Leaving the outer shell thickness of the framework at 0.5 mm, two different internal designs with hollow geometries were created (1.5 mm and 2 mm inner bar distances) and a cross section area of the connector was calculated. The weights of the specimens were measured and subjected to a 3-point-bending test at 1 mm/min crosshead speed. Data were statistically analyzed using One-way ANOVA followed by Tukey (α = 0.05). RESULTS There was a statistically significant difference among the groups in terms of weight of the specimens (p ≤ 0.05). However, no significant difference was observed among groups in term of both flexural strength and flexural modulus (p ≤ 0.05). CONCLUSIONS Within the limitations of the study, it was concluded that changing the internal design of the metal frameworks decreases the weight of the framework, but does not affect the flexural strength and flexural modulus. Therefore, clinical applications of internally modified frameworks seem promising for metal-ceramic restorations.
Collapse
Affiliation(s)
- Elif Figen Kocak
- Department of Prosthodontics, Faculty of Dentistry, Çukurova University, Adana, Turkey.,Abdi Sutcu Vocational School of Health Services, Çukurova University, Adana, Turkey
| | - Orhun Ekren
- Department of Prosthodontics, Faculty of Dentistry, Çukurova University, Adana, Turkey
| | - Yurdanur Ucar
- Department of Prosthodontics, Faculty of Dentistry, Çukurova University, Adana, Turkey
| |
Collapse
|
10
|
Valenti C, Isabella Federici M, Masciotti F, Marinucci L, Xhimitiku I, Cianetti S, Pagano S. Mechanical properties of 3D-printed prosthetic materials compared with milled and conventional processing: A systematic review and meta-analysis of in vitro studies. J Prosthet Dent 2022:S0022-3913(22)00415-2. [PMID: 35934576 DOI: 10.1016/j.prosdent.2022.06.008] [Citation(s) in RCA: 22] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2022] [Revised: 06/22/2022] [Accepted: 06/22/2022] [Indexed: 11/23/2022]
Abstract
STATEMENT OF PROBLEM Three-dimensional (3D) additive manufacturing (AM) is an evolving technology in dentistry, proposed as an alternative to subtractive milling manufacture (MM) or conventional processing. However, a systematic review of the use of AM technology instead of milling or conventional processing is lacking. PURPOSE The purpose of this systematic review and meta-analysis was to evaluate the mechanical properties of 3D-printed prosthetic materials compared with MM and conventional techniques. MATERIAL AND METHODS An electronic search of the literature was conducted on the MEDLINE (via PubMed), Scopus, and Web of Science databases. The inclusion criteria were in vitro studies published in the last 5 years, in English or Italian, and with 3D AM printed dental prosthetic materials. Data extraction was focused on dental prosthetic materials (ceramics, polymers, and metals) and their mechanical properties: flexural strength, fracture load, hardness, roughness, removable partial denture (RPD) fit accuracy, trueness, marginal discrepancy, and internal fit. Data considered homogenous were subjected to meta-analysis using the Stata17 statistical software program (95% confidence interval [CI]; α=.05). Since all variables were continuous, the Hedge g measure was calculated. A fixed-effects model was used for I2=0%, while the statistical analysis was conducted using a random-effects model with I2>0%. RESULTS From a total of 3624 articles, 2855 studies were selected, and 76 studies included after full-text reading. The roughness of AM-printed ceramics generally increased compared with that of conventional processing while the marginal discrepancy was comparable both for ceramics and polymers. The flexural strength, hardness, and fracture load of AM-printed polymers were statistically lower than those of the conventional group (P<.05). No significant difference was detected in terms of hardness, roughness, marginal discrepancy, fracture load, trueness, or internal fit between the AM and MM techniques (P>.05). Milling techniques showed significantly higher values of flexural strength (Hedge g=-3.88; 95% CI, -7.20 to -0.58; P=.02), also after aging (Hedge g=-3.29; 95% CI, -6.41 to -0.17; P=.04), compared with AM printing. CONCLUSIONS AM is comparable with MM in terms of mechanical properties, in particular with polymeric materials. The flexural strength of AM-printed prostheses is lower than with conventional and MM techniques, as are the parameters of hardness and fracture load, while the marginal discrepancy is similar to that of MM and conventional techniques. AM prostheses are commonly used for interim crowns and fixed partial dentures, as their rigidity and fracture resistance cannot support mastication forces for extended periods. More comparative studies are needed.
Collapse
Affiliation(s)
- Chiara Valenti
- Graduate student, Department of Medicine and Surgery, Odontostomatological University Centre, University of Perugia, Perugia, Italy
| | - Maria Isabella Federici
- Graduate student, Department of Medicine and Surgery, Odontostomatological University Centre, University of Perugia, Perugia, Italy
| | - Francesca Masciotti
- Student, Department of Medicine and Surgery, Odontostomatological University Centre, University of Perugia, Perugia, Italy
| | - Lorella Marinucci
- Researcher, Section of Biosciences and Medical Embryology, Department of Medicine and Surgery, University of Perugia, Perugia, Italy
| | - Iva Xhimitiku
- PhD student, Centro di Ateneo di Studi e Attività Spaziali "Giuseppe Colombo" - CISAS, University of Padua, Padua, Italy
| | - Stefano Cianetti
- Professor, Department of Medicine and Surgery, Odontostomatological University Centre, University of Perugia, Perugia, Italy
| | - Stefano Pagano
- Researcher, Department of Medicine and Surgery, Odontostomatological University Centre, University of Perugia, Perugia, Italy.
| |
Collapse
|
11
|
Characterization of Co-Cr-W Dental Alloys with Veneering Materials Manufactured via Subtractive Milling and Additive Manufacturing LDED Methods. MATERIALS 2022; 15:ma15134624. [PMID: 35806747 PMCID: PMC9267738 DOI: 10.3390/ma15134624] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/21/2022] [Revised: 06/27/2022] [Accepted: 06/29/2022] [Indexed: 11/25/2022]
Abstract
Laser-directed energy deposition (LDED) is an additive manufacturing (AM) technology which can be an alternative to the traditional subtractive milling process for the obtention of porcelain-fused-to-metal (PFM) prosthesis. Still, the adhesion performance of the veneering ceramics for this material has been not studied yet. The main objective of this study is to perform a systematic comparison of the adhesion performance of Co-Cr-W metal frameworks obtained through LDED and conventional milling techniques. Comparison includes microstructural, superficial, and adhesion analysis. Co-Cr manufactured via LDED technique presents similar behavior (p < 0.05) in comparison to the material obtained via milling techniques, and its performance was validated with the veneering ceramics and veneering composites currently employed in the dental industry.
Collapse
|
12
|
Tobar C, Rodriguez V, Lopez-Suarez C, Pelaez J, Suarez MJ. Influence of Digital Technologies and Framework Design on the Load to Fracture of Co-Cr Posterior Fixed Partial Denture Frameworks. J Prosthodont 2021; 31:606-613. [PMID: 34860426 DOI: 10.1111/jopr.13458] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/25/2021] [Indexed: 12/01/2022] Open
Abstract
PURPOSE To compare the load to fracture of cobalt-chromium (Co-Cr) 3-unit posterior fixed partial denture (FPD) frameworks manufactured by conventional and digital techniques and to evaluate the influence of the framework design on the fracture load. MATERIAL AND METHODS Eighty 3-unit Co-Cr posterior FPD frameworks were fabricated with two designs: intermediate pontic (n = 40) and cantilever (n = 40). Each design was randomly divided into four groups (n = 10): casting, direct metal laser sintering, soft metal milling, and hard metal milling. After thermal cycling, all specimens were subjected to a 3-point bending test until fracture. Data were statistically analyzed using one-way ANOVA, Welch and Brown-Forsythe test, Ryan-Einot-Gabriel-Welsch F and Tamhane T2 post hoc test, Student's t test, and Weibull statistics (α = 0.05). RESULTS Significant differences (p < 0.001; F = 39.59) were found among intermediate pontic frameworks (except between laser sintering and hard metal milling), and cantilevered frameworks (F = 36.75) (except between laser sintering and hard metal milling, and casting and soft metal milling). The cantilever groups showed load to fracture values significantly lower than those of the intermediate pontic (p < 0.001; F = 28.29). The Weibull statistics corroborated the results. CONCLUSIONS Hard metal milling and laser sintered frameworks exhibited the highest load to fracture values. However, all tested frameworks demonstrated clinically acceptable load to fracture values. The framework design directly affected the fracture load, with drastically lower values in cantilevered frameworks.
Collapse
Affiliation(s)
- Celia Tobar
- Department of Conservative Dentistry and Buccofacial Prostheses, Faculty of Odontology, University Complutense of Madrid, Madrid, Spain
| | - Veronica Rodriguez
- Department of Conservative Dentistry and Buccofacial Prostheses, Faculty of Odontology, University Complutense of Madrid, Madrid, Spain
| | - Carlos Lopez-Suarez
- Department of Conservative Dentistry and Buccofacial Prostheses, Faculty of Odontology, University Complutense of Madrid, Madrid, Spain
| | - Jesus Pelaez
- Department of Conservative Dentistry and Buccofacial Prostheses, Faculty of Odontology, University Complutense of Madrid, Madrid, Spain
| | - Maria J Suarez
- Department of Conservative Dentistry and Buccofacial Prostheses, Faculty of Odontology, University Complutense of Madrid, Madrid, Spain
| |
Collapse
|
13
|
Additively Manufactured Commercial Co-Cr Dental Alloys: Comparison of Microstructure and Mechanical Properties. MATERIALS 2021; 14:ma14237350. [PMID: 34885499 PMCID: PMC8658371 DOI: 10.3390/ma14237350] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/04/2021] [Revised: 11/23/2021] [Accepted: 11/27/2021] [Indexed: 12/03/2022]
Abstract
Laser-powder bed fusion (LPBF) is one of the preferred techniques for producing Co-Cr metal structures for dental prosthodontic appliances. However, there is generally insufficient information about material properties related to the production process and parameters. This study was conducted on samples produced from three different commercially available Co-Cr dental alloys produced on three different LPBF machines. Identically prepared samples were used for tensile, three-point bending, and toughness tests. Light microscopy (LM), scanning electron microscopy (SEM), and electron backscatter diffraction (EBSD) analyses of microstructure were performed after testing. Differences were observed in microstructures, which reflected statistically significant differences in mechanical properties (one-way analysis of variance (ANOVA) and Scheffé post hoc test (α = 0.05)). The material produced on the 3D Systems DMP Dental 100 had 24 times greater elongation ε than the material produced on the Sysma MySint 100 device and the EOS M100 machine. On the other hand, the material produced on the EOS M100 had significantly higher hardness (HV0.2) than the other two produced materials. However, the microstructure of the Sysma specimens with its morphology deviates considerably from the studied group. LPBF-prepared Co-Cr dental alloys demonstrated significant differences in their microstructures and, consequently, mechanical properties.
Collapse
|
14
|
Cha MS, Lee SW, Huh YH, Cho LR, Park CJ. Correlation between microhardness and wear resistance of dental alloys against monolithic zirconia. J Adv Prosthodont 2021; 13:127-135. [PMID: 34234922 PMCID: PMC8250188 DOI: 10.4047/jap.2021.13.3.127] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2021] [Revised: 06/07/2021] [Accepted: 06/09/2021] [Indexed: 11/30/2022] Open
Abstract
PURPOSE The aim of this study is to compare the hardness according to the conditions of metal alloys. Moreover, the correlation between the cast crown hardness before and after wear testing and the degree of wear for each dental alloy was assessed. MATERIALS AND METHODS Cast crowns of three metal alloys (Co-Cr, gold, and Ni-Cr alloys) opposing smooth-surface monolithic zirconia were used. The Vickers microhardness of the ingot (which did not undergo wear testing) and the cast crown before and after wear testing were measured for each alloy. Two-way ANOVA and Scheffé tests were used to compare the measured hardness values. Moreover, the Pearson correlation coefficient was used to evaluate the relationship between the surface hardness and the wear of the cast crown (α=.05). RESULTS There was no significant difference in the hardness before and after wear testing for the gold alloy (P>.05); however, the hardness of the worn surface of the cast crown increased compared to that of the cast crown before the wear tests of Ni-Cr and Co-Cr alloys (P<.05). Furthermore, there was no correlation between the wear and hardness of the cast crown before and after wear testing for all three metal alloys (P>.05). CONCLUSION There was a significant difference in hardness between dental alloys under the same conditions. No correlation existed between the surface hardness of the cast crown before and after wear testing and the wear of the cast crown.
Collapse
Affiliation(s)
- Min-Sang Cha
- Department of Dentistry, Gangneung Asan Hospital, University of Ulsan College of Medicine, Gangneung, Republic of Korea
| | - Sang-Woon Lee
- Department of Dentistry, Gangneung Asan Hospital, University of Ulsan College of Medicine, Gangneung, Republic of Korea
| | - Yoon-Hyuk Huh
- Department of Prosthodontics and Research Institute of Oral Science, College of Dentistry, Gangneung-Wonju National University, Gangneung, Republic of Korea
| | - Lee-Ra Cho
- Department of Prosthodontics and Research Institute of Oral Science, College of Dentistry, Gangneung-Wonju National University, Gangneung, Republic of Korea
| | - Chan-Jin Park
- Department of Prosthodontics and Research Institute of Oral Science, College of Dentistry, Gangneung-Wonju National University, Gangneung, Republic of Korea
| |
Collapse
|
15
|
Fracture Load of Metal, Zirconia and Polyetheretherketone Posterior CAD-CAM Milled Fixed Partial Denture Frameworks. MATERIALS 2021; 14:ma14040959. [PMID: 33670544 PMCID: PMC7922591 DOI: 10.3390/ma14040959] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/26/2021] [Revised: 02/10/2021] [Accepted: 02/15/2021] [Indexed: 01/02/2023]
Abstract
The aim of this study was to investigate the load to fracture and fracture pattern of prosthetic frameworks for tooth-supported fixed partial dentures (FPDs) fabricated with different subtractive computer-aided design and computer-aided manufacturing (CAD-CAM) materials. Materials and Methods: Thirty standardized specimens with two abutments were fabricated to receive three-unit posterior FDP frameworks with an intermediate pontic. Specimens were randomly divided into three groups (n = 10 each) according to the material: group 1 (MM)—milled metal; group 2 (L)—zirconia; and group 3 (P)—Polyetheretherketone (PEEK). The specimens were thermo-cycled and subjected to a three-point bending test until fracture using a universal testing machine (cross-head speed: 1 mm/min). Axial compressive loads were applied at the central fossa of the pontics. Data analysis was made using one-way analysis of variance, Tamhane post hoc test, and Weibull statistics (α = 0.05). Results: Significant differences were observed among the groups for the fracture load (p < 0.0001). MM frameworks showed the highest fracture load values. The PEEK group registered higher fracture load values than zirconia samples. The Weibull statistics corroborated these results. The fracture pattern was different among the groups. Conclusions: Milled metal provided the highest fracture load values, followed by PEEK, and zirconia. However, all tested groups demonstrated clinically acceptable fracture load values higher than 1000 N. PEEK might be considered a promising alternative for posterior FPDs.
Collapse
|
16
|
Cosma C, Moldovan M, Simion M, Balc N. Impact of laser parameters on additively manufactured cobalt-chromium restorations. J Prosthet Dent 2021; 128:421-429. [PMID: 33610328 DOI: 10.1016/j.prosdent.2020.11.043] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2020] [Revised: 11/11/2020] [Accepted: 11/11/2020] [Indexed: 10/22/2022]
Abstract
STATEMENT OF PROBLEM The selective laser melting (SLM) process has become popular for the fabrication of frameworks for metal-ceramic restorations, although their surface roughness is greater than with cast or milled frameworks. Limited information is available regarding the surface mechanical characteristics of cobalt-chromium (Co-Cr) SLM-manufactured restorations. PURPOSE The purpose of this in vitro study was to adapt the laser parameters for a remelting strategy, scanning the outer boundary of Co-Cr specimens, to reduce surface roughness and solidification defects, to determine microhardness, to investigate surface morphology and microstructure, and to establish surface mechanical characteristics. MATERIAL AND METHODS Co-Cr specimens were SLM manufactured by using a typical melting (TM) strategy and an adaptive remelting (AR) strategy. The AR strategy involves rescanning 50% of the contour, varying the laser parameters. The roughness parameters considered were Ra and Rz. Vickers hardness was measured by microindentation with a 9.81-N force (ASTM E384-17). The surface morphology was investigated by scanning electron microscopy, the chemical composition by energy-dispersive X-ray spectroscopy, and the phase identification by using X-ray diffraction. The mechanical surface properties measured were the nanohardness, elastic modulus, and dissipation energy. One-way ANOVA with the Tukey procedure was used to compare the groups (α=.05). RESULTS The innovative AR strategy reduced the surface roughness by 45% compared with TM, comparable with their cast counterpart. The smoothest AR surface was obtained by using 75 W and 350 mm/s for the first scanning of the contour, followed by a second remelting with 80 W and 700 mm/s. The microstructure of AR specimens had limited solidification defects, a chemical composition similar to that of raw powder, and a surface microhardness over 600 HV1. A fine grain structure in a single matrix phase was detected both on TM and AR specimens. The mechanical characteristics of the smoothest Co-Cr surface were 218 GPa elastic modulus, 746 HVIT Vickers nanohardness, 21 243 pJ plastic energy, and 26% nanoindentation work ratio. Significant differences were observed between the melting strategies (P<.05) both for surface roughness and microhardness. CONCLUSIONS The laser scanning strategy affects both the surface roughness and the hardness of SLM-manufactured specimens. The results show that using the AR strategy and proper laser parameters can reduce the roughness and increase the surface hardness of Co-Cr specimens made of conventional powder feedstock.
Collapse
Affiliation(s)
- Cosmin Cosma
- Researcher, National Centre of Rapid Prototyping, Technical University of Cluj-Napoca, Cluj-Napoca, Romania.
| | - Marioara Moldovan
- Researcher professor and Head of Polymeric Composite Laboratory, Institute for Research in Chemistry Raluca Ripan, Babes-Bolyai University, Cluj-Napoca, Romania
| | - Mihaela Simion
- Senior Lecturer, Department of Strength of Materials, Technical University of Cluj-Napoca, Cluj-Napoca, Romania
| | - Nicolae Balc
- Professor and Dean, Faculty of Machine Building, Technical University of Cluj-Napoca, Cluj-Napoca, Romania
| |
Collapse
|
17
|
Mechanical Properties and Metal-Ceramic Bond Strength of Co-Cr Alloy Manufactured by Selective Laser Melting. MATERIALS 2020; 13:ma13245745. [PMID: 33339320 PMCID: PMC7766189 DOI: 10.3390/ma13245745] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/23/2020] [Revised: 12/08/2020] [Accepted: 12/14/2020] [Indexed: 01/04/2023]
Abstract
Cobalt–chromium (Co-Cr) metal is one of the widely used biomaterials in the fabrication of dental prosthesis. The purpose of this study was to investigate whether there are differences in the properties of metals and bond strength with ceramics depending on the manufacturing methods of Co-Cr alloy. Co-Cr alloy specimens were prepared in three different ways: casting, milling, and selective laser melting (SLM). The mechanical properties (elastic modulus, yield strength, and flexural strength) of the alloys were investigated by flexure method in three-point bending mode, and microstructures of the specimens were analyzed. After application of the veneering ceramic through the three-point bending test, bond strength of the Metal-Ceramic was investigated. The cracked surfaces were observed by means of energy dispersive X-ray (EDX) spectroscopy and scanning electron microscopy (SEM) with backscattered electron (BSE) images. In mechanical properties, the elastic modulus was highest for the casting group, and the yield strength and flexural strength were lowest for the milling group. The SLM group showed finer homogeneous crystalline-microstructure, and a layered structure was observed at the fractured surface. After the ceramic bond strength test, all groups showed a mixed failure pattern. The casting group showed the highest bond strengths, whereas there was no significant difference between the other two groups. However, all groups have met the standard of bond strength according to international standards organization (ISO) with the appropriate passing rate. The results of this study indicate that the SLM manufacturing method may have the potential to replace traditional techniques for fabricating dental prosthesis.
Collapse
|
18
|
Yan X, Jiang R, Li W, Lin H. Oriented face-centered cubic to hexagonal close-packed martensitic transition, grain morphology, and mechanical properties of Co-Cr alloy fabricated by selective laser melting. J Prosthet Dent 2020; 127:282-287. [PMID: 33279164 DOI: 10.1016/j.prosdent.2020.07.036] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2020] [Revised: 07/14/2020] [Accepted: 07/14/2020] [Indexed: 10/22/2022]
Abstract
STATEMENT OF PROBLEM Removable partial dentures (RPDs) can be fabricated by selective laser melting (SLM) with different build orientations. How microstructures and mechanical properties of SLM Co-Cr alloy are affected by different build orientations is unclear. PURPOSE The purpose of this in vitro study was to investigate the phase structures, grain morphology, and mechanical properties of SLM Co-Cr alloy with different build orientations. MATERIAL AND METHODS SLM Co-Cr tensile specimens were fabricated at orientation angles of 0, 45, and 90 degrees between the building and longitudinal direction named the T0, T45, and T90 design groups (n=14). Mechanical properties were obtained by tensile testing conducted by using a universal testing machine according to the International Organization for Standardization (ISO) 22674. The grains along the longitudinal direction of the specimens and phase structures were observed before and after tensile testing by electron backscatter diffraction. One-way analysis of variance followed by the Bonferroni post hoc test and Kruskal-Wallis test were used for statistical analysis (α=.05). RESULTS The 0.2% yield strengths in descending order were T90 (870 MPa)>T45 (840 MPa)>T0 (786 MPa) (P<.05); the elongations were T0 (21.8%)>T45 (15.6%)>T90 (8.7%) (P<.05); the ultimate tensile strengths were T45 (1226 MPa)>T90 (1200 MPa)>T0 (1149 MPa) (P<.05). The average grain sizes in the T0, T45, and T90 groups were 22 μm, 18 μm, and 14 μm, respectively. After the tensile test, a face-centered cubic (FCC) to hexagonal close-packed (HCP) martensitic transition was found in each group, and the phase transition area fractions were T0 (38.3%)>T45 (11.4%)>T90 (0.7%). CONCLUSIONS The FCC to HCP martensitic transition, grain morphology, and mechanical properties of SLM Co-Cr alloy depended on the build orientations. The oriented phase transition and grains affected the anisotropic mechanical properties of SLM Co-Cr alloy.
Collapse
Affiliation(s)
- Xiang Yan
- Assistant, Department of Dental Materials Laboratory, Hospital of Stomatology, Peking University, Beijing, PR China
| | - Ruodan Jiang
- Engineer, Department of Dental Materials Laboratory, Hospital of Stomatology, Peking University, Beijing, PR China
| | - Wen Li
- Engineer, Department of Dental Materials Laboratory, Hospital of Stomatology, Beijing, PR China
| | - Hong Lin
- Professor and Director, Department of Dental Materials Laboratory, National Medical Products Administration Key Laboratory for Dental Materials & Dental Medical Devices Testing Center, Peking University School of Stomatology, Beijing, PR China.
| |
Collapse
|
19
|
Challenges of Co-Cr Alloy Additive Manufacturing Methods in Dentistry-The Current State of Knowledge (Systematic Review). MATERIALS 2020; 13:ma13163524. [PMID: 32785055 PMCID: PMC7475880 DOI: 10.3390/ma13163524] [Citation(s) in RCA: 26] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/18/2020] [Revised: 07/29/2020] [Accepted: 08/04/2020] [Indexed: 12/28/2022]
Abstract
Complex dental components which are individually tailored to the patient can be obtained due to new additive manufacturing technology. This paper reviews the metallic powders used in dental applications, the fabrication process (build orientation, process parameters) and post-processing processes (stress relieving, surface finishing). A review of the literature was performed using PubMed, ScienceDirect, Mendeley and Google Scholar. Over eighty articles were selected based on relevance to this review. This paper attempts to include the latest research from 2010 until 2020, however, older manuscripts (10 articles) were also selected. Over 1200 records were identified through the search; these were screened for title and/or summary. Over eighty articles were selected based on relevance to this review. In order to obtain a product which can be used in clinical applications, the appropriate manufacturing parameters should be selected. A discussion was made on optimal selective laser melting (SLM) parameters in dentistry. In addition, this paper includes a critical review of applied thermal treatment methods for Co-Cr alloys used in dentistry.
Collapse
|
20
|
Abstract
Implant dentistry has shifted to prosthetically guided implant planning and placement. This shift has influenced the range of available dental materials to restore single crowns and partially and fully edentulous jaws with dental implants. This article presents an overview of the available options to restore dental implants. The qualities that define an ideal restoring material are discussed along with the most commonly used materials with their advantages and limitations. Because clinicians face different clinical scenarios in their practice, the discussion sums up the best techniques and materials that are useful in addressing these nonideal situations.
Collapse
|