1
|
Rast FM, Herren S, Labruyère R. Acceptability of wearable inertial sensors, completeness of data, and day-to-day variability of everyday life motor activities in children and adolescents with neuromotor impairments. FRONTIERS IN REHABILITATION SCIENCES 2022; 3:923328. [PMID: 36569637 PMCID: PMC9788775 DOI: 10.3389/fresc.2022.923328] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 04/19/2022] [Accepted: 09/01/2022] [Indexed: 12/13/2022]
Abstract
Monitoring the patients' motor activities in a real-world setting would provide essential information on their functioning in daily life. In this study, we used wearable inertial sensors to monitor motor activities of children and adolescents with congenital and acquired brain injuries. We derived a set of clinically meaningful performance measures and addressed the following research questions: Is the target population willing to wear the sensors in their habitual environment? Which factors lead to missing data, and can we avoid them? How many measurement days are needed to obtain reliable estimates of the children's and adolescents' motor performance? The study participants wore our sensor system for seven consecutive days during waking hours. First, we derived the daily hand use of all participants, the duration of different body positions and the wheeling activity of individuals using a manual wheelchair, and walking-related measures in individuals being able to walk. Then, we analyzed the reasons for missing data and determined the reliability of the performance measures mentioned above. The large majority (41 of 43 participants) was willing to wear the sensor system for a week. However, forgetting to reattach the sensors after charging them overnight and taking them off during bathing and swimming was the main contributor to missing data. Consequently, improved battery life and waterproofness of the sensor technology are essential requirements for measurements in daily life. Besides, 5 of 11 performance measures showed significant differences between weekdays and weekend days. The reliability, measured with the intraclass correlation coefficient, ranged between 0.82 and 0.98. Seven measurement days were enough to obtain significantly higher reliability scores than the desired level of 0.8 for all but two performance measures. In children and adolescents with neuromotor impairments, we recommend monitoring everyday life motor activities on seven consecutive days. The target population accepted this measurement protocol, it covers school days and weekend days, and the number of measurement days is sufficient to obtain reliable estimates of motor performance.
Collapse
Affiliation(s)
- Fabian Marcel Rast
- Swiss Children’s Rehab, University Children’s Hospital Zurich, Affoltern am Albis, Switzerland
- Children’s Research Center, University Children’s Hospital of Zurich, University of Zurich, Zurich, Switzerland
- Rehabilitation Engineering Laboratory, Department of Health Sciences and Technology, ETH Zurich, Zurich, Switzerland
| | - Silvia Herren
- Swiss Children’s Rehab, University Children’s Hospital Zurich, Affoltern am Albis, Switzerland
- Children’s Research Center, University Children’s Hospital of Zurich, University of Zurich, Zurich, Switzerland
| | - Rob Labruyère
- Swiss Children’s Rehab, University Children’s Hospital Zurich, Affoltern am Albis, Switzerland
- Children’s Research Center, University Children’s Hospital of Zurich, University of Zurich, Zurich, Switzerland
| |
Collapse
|
2
|
Xiong JSP, Reedman SE, Kho ME, Timmons BW, Verschuren O, Gorter JW. Operationalization, measurement, and health indicators of sedentary behavior in individuals with cerebral palsy: a scoping review. Disabil Rehabil 2021; 44:6070-6081. [PMID: 34334077 DOI: 10.1080/09638288.2021.1949050] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
PURPOSE To explore the operationalization and measurement of sedentary behavior (SB) in individuals with cerebral palsy (CP). MATERIALS AND METHODS We searched five databases from 2011 to 2020 for primary studies of experimental, qualitative, longitudinal, or observational designs measuring SB or postures typically characterized as sedentary (sitting, reclining, lying). RESULTS We screened 1112 citations and selected 47 studies. SB was operationalized through muscle activation, energy expenditure or oxygen consumption in typically sedentary postures (n = 9), and through thresholds and postures used by accelerometers, activity monitors, and a questionnaire to measure time spent in SB (n = 25). Seven out of the eight studies that measured energy expenditure found ≤1.5 metabolic equivalents of task (METs) for sitting and lying. While different accelerometer thresholds were used to measure SB, the behavior (SB) was consistently operationalized as sitting and lying. Little consistency existed in the subpopulation, instruments and cut-points for studies on validity or reliability of tools for measuring SB (n = 19). CONCLUSIONS Sitting and lying are considered sedentary postures, which is defined as ≤1.5 METs in individuals with CP. There is variability in the tools used to measure SB in individuals with CP. Therefore, consensus on the definition and reporting of SB is needed.Implications for rehabilitationAlthough sedentary behavior (SB) is increased in individuals with cerebral palsy (CP) compared to the typically developing population, there is no standard definition for SB for these individuals; this makes it difficult to synthesize data across studies.Sitting and lying are ≤1.5 METs in individuals with CP, suggesting we only need to measure posture to show change in SB.The commonly used accelerometer cut-point in the typically developing population of ≤100 counts per minute generally has excellent reliability across multiple devices in ambulatory children with CP.
Collapse
Affiliation(s)
- Julia Shi-Peng Xiong
- Faculty of Health Sciences, School of Rehabilitation Science, McMaster University, Institute of Applied Health Sciences, Hamilton, Canada
| | - Sarah E Reedman
- Queensland Cerebral Palsy and Rehabilitation Research Centre, Child Health Research Centre, The University of Queensland, South Brisbane, Australia
| | - Michelle E Kho
- Faculty of Health Sciences, School of Rehabilitation Science, McMaster University, Institute of Applied Health Sciences, Hamilton, Canada.,Department of Physiotherapy, St. Joseph's Healthcare Hamilton, Hamilton, Canada
| | - Brian W Timmons
- Department of Pediatrics, Child Health and Exercise Medicine Program, McMaster University, Hamilton, Canada.,Department of Kinesiology, McMaster University, Hamilton, Canada
| | - Olaf Verschuren
- UMC Utrecht Brain Center and Center of Excellence for Rehabilitation Medicine, Utrecht University, Utrecht and De Hoogstraat Rehabilitation, Utrecht, Netherlands
| | - Jan Willem Gorter
- Faculty of Health Sciences, School of Rehabilitation Science, McMaster University, Institute of Applied Health Sciences, Hamilton, Canada.,Department of Pediatrics, CanChild Centre for Childhood Disability Research, McMaster University, Hamilton, Canada.,Department of Pediatrics, McMaster University, Hamilton, Canada
| |
Collapse
|
3
|
Spatio-temporal gait parameters obtained from foot-worn inertial sensors are reliable in healthy adults in single- and dual-task conditions. Sci Rep 2021; 11:10229. [PMID: 33986307 PMCID: PMC8119721 DOI: 10.1038/s41598-021-88794-4] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2020] [Accepted: 04/07/2021] [Indexed: 02/07/2023] Open
Abstract
Inertial measurement units (IMUs) are increasingly popular and may be usable in clinical routine to assess gait. However, assessing their intra-session reliability is crucial and has not been tested with foot-worn sensors in healthy participants. The aim of this study was to assess the intra-session reliability of foot-worn IMUs for measuring gait parameters in healthy adults. Twenty healthy participants were enrolled in the study and performed the 10-m walk test in single- and dual-task ('carrying a full cup of water') conditions, three trials per condition. IMUs were used to assess spatiotemporal gait parameters, gait symmetry parameters (symmetry index (SI) and symmetry ratio (SR)), and dual task effects parameters. The relative and the absolute reliability were calculated for each gait parameter. Results showed that spatiotemporal gait parameters measured with foot-worn inertial sensors were reliable; symmetry gait parameters relative reliability was low, and SR showed better absolute reliability than SI; dual task effects were poorly reliable, and taking the mean of the second and the third trials was the most reliable. Foot-worn IMUs are reliable to assess spatiotemporal and symmetry ratio gait parameters but symmetry index and DTE gait parameters reliabilities were low and need to be interpreted with cautious by clinicians and researchers.
Collapse
|
4
|
Rast FM, Labruyère R. Systematic review on the application of wearable inertial sensors to quantify everyday life motor activity in people with mobility impairments. J Neuroeng Rehabil 2020; 17:148. [PMID: 33148315 PMCID: PMC7640711 DOI: 10.1186/s12984-020-00779-y] [Citation(s) in RCA: 31] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2020] [Accepted: 10/22/2020] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Recent advances in wearable sensor technologies enable objective and long-term monitoring of motor activities in a patient's habitual environment. People with mobility impairments require appropriate data processing algorithms that deal with their altered movement patterns and determine clinically meaningful outcome measures. Over the years, a large variety of algorithms have been published and this review provides an overview of their outcome measures, the concepts of the algorithms, the type and placement of required sensors as well as the investigated patient populations and measurement properties. METHODS A systematic search was conducted in MEDLINE, EMBASE, and SCOPUS in October 2019. The search strategy was designed to identify studies that (1) involved people with mobility impairments, (2) used wearable inertial sensors, (3) provided a description of the underlying algorithm, and (4) quantified an aspect of everyday life motor activity. The two review authors independently screened the search hits for eligibility and conducted the data extraction for the narrative review. RESULTS Ninety-five studies were included in this review. They covered a large variety of outcome measures and algorithms which can be grouped into four categories: (1) maintaining and changing a body position, (2) walking and moving, (3) moving around using a wheelchair, and (4) activities that involve the upper extremity. The validity or reproducibility of these outcomes measures was investigated in fourteen different patient populations. Most of the studies evaluated the algorithm's accuracy to detect certain activities in unlabeled raw data. The type and placement of required sensor technologies depends on the activity and outcome measure and are thoroughly described in this review. The usability of the applied sensor setups was rarely reported. CONCLUSION This systematic review provides a comprehensive overview of applications of wearable inertial sensors to quantify everyday life motor activity in people with mobility impairments. It summarizes the state-of-the-art, it provides quick access to the relevant literature, and it enables the identification of gaps for the evaluation of existing and the development of new algorithms.
Collapse
Affiliation(s)
- Fabian Marcel Rast
- Swiss Children’s Rehab, University Children’s Hospital Zurich, Mühlebergstrasse 104, 8910 Affoltern am Albis, Switzerland
- Children’s Research Center, University Children’s Hospital of Zurich, University of Zurich, Zurich, Switzerland
- Rehabilitation Engineering Laboratory, Department of Health Sciences and Technology, ETH Zurich, Zurich, Switzerland
| | - Rob Labruyère
- Swiss Children’s Rehab, University Children’s Hospital Zurich, Mühlebergstrasse 104, 8910 Affoltern am Albis, Switzerland
- Children’s Research Center, University Children’s Hospital of Zurich, University of Zurich, Zurich, Switzerland
| |
Collapse
|
5
|
Multidimensional Measures of Physical Activity and Their Association with Gross Motor Capacity in Children and Adolescents with Cerebral Palsy. SENSORS 2020; 20:s20205861. [PMID: 33081346 PMCID: PMC7589543 DOI: 10.3390/s20205861] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/11/2020] [Revised: 10/09/2020] [Accepted: 10/12/2020] [Indexed: 01/06/2023]
Abstract
The current lack of adapted performance metrics leads clinicians to focus on what children with cerebral palsy (CP) do in a clinical setting, despite the ongoing debate on whether capacity (what they do at best) adequately reflects performance (what they do in daily life). Our aim was to measure these children’s habitual physical activity (PA) and gross motor capacity and investigate their relationship. Using five synchronized inertial measurement units (IMU) and algorithms adapted to this population, we computed 22 PA states integrating the type (e.g., sitting, walking, etc.), duration, and intensity of PA. Their temporal sequence was visualized with a PA barcode from which information about pattern complexity and the time spent in each of the six simplified PA states (PAS; considering PA type and duration, but not intensity) was extracted and compared to capacity. Results of 25 children with CP showed no strong association between motor capacity and performance, but a certain level of motor capacity seems to be a prerequisite for the achievement of higher PAS. Our multidimensional performance measurement provides a new method of PA assessment in this population, with an easy-to-understand visual output (barcode) and objective data for clinical and scientific use.
Collapse
|
6
|
Carmona-Pérez C, Pérez-Ruiz A, Garrido-Castro JL, Vidal FT, Alcaraz-Clariana S, García-Luque L, Rodrigues-de-Souza DP, Alburquerque-Sendín F. Design, Validity, and Reliability of a New Test, Based on an Inertial Measurement Unit System, for Measuring Cervical Posture and Motor Control in Children with Cerebral Palsy. Diagnostics (Basel) 2020; 10:E661. [PMID: 32882885 PMCID: PMC7555956 DOI: 10.3390/diagnostics10090661] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2020] [Revised: 08/27/2020] [Accepted: 08/31/2020] [Indexed: 11/23/2022] Open
Abstract
OBJECTIVE The aim of this study was to design and propose a new test based on inertial measurement unit (IMU) technology, for measuring cervical posture and motor control in children with cerebral palsy (CP) and to evaluate its validity and reliability. METHODS Twenty-four individuals with CP (4-14 years) and 24 gender- and age-matched controls were evaluated with a new test based on IMU technology to identify and measure any movement in the three spatial planes while the individual is seated watching a two-minute video. An ellipse was obtained encompassing 95% of the flexion/extension and rotation movements in the sagittal and transversal planes. The protocol was repeated on two occasions separated by 3 to 5 days. Construct and concurrent validity were assessed by determining the discriminant capacity of the new test and by identifying associations between functional measures and the new test outcomes. Relative reliability was determined using the intraclass correlation coefficient (ICC) for test-retest data. Absolute reliability was obtained by the standard error of measurement (SEM) and the Minimum Detectable Change at a 90% confidence level (MDC90). RESULTS The discriminant capacity of the area and both dimensions of the new test was high (Area Under the Curve ≈ 0.8), and consistent multiple regression models were identified to explain functional measures with new test results and sociodemographic data. A consistent trend of ICCs higher than 0.8 was identified for CP individuals. Finally, the SEM can be considered low in both groups, although the high variability among individuals determined some high MDC90 values, mainly in the CP group. CONCLUSIONS The new test, based on IMU data, is valid and reliable for evaluating posture and motor control in children with CP.
Collapse
Affiliation(s)
- Cristina Carmona-Pérez
- Centro de Recuperación Neurológica de Córdoba (CEDANE), 14005 Córdoba, Spain;
- Doctoral Program in Biomedicine, University of Córdoba, 14004 Córdoba, Spain; (S.A.-C.); (L.G.-L.)
| | - Alberto Pérez-Ruiz
- Department of Nursing, Pharmacology and Physical Therapy, Faculty of Medicine and Nursing, University of Córdoba, 14004 Córdoba, Spain; (A.P.-R.); (F.A.-S.)
| | - Juan L. Garrido-Castro
- Department of Computer Science and Numerical Analysis, Rabanales Campus, University of Córdoba, 14071 Córdoba, Spain; (J.L.G.-C.); (F.T.V.)
- Maimonides Biomedical Research Institute of Cordoba (IMIBIC), 14004 Córdoba, Spain
| | - Francisco Torres Vidal
- Department of Computer Science and Numerical Analysis, Rabanales Campus, University of Córdoba, 14071 Córdoba, Spain; (J.L.G.-C.); (F.T.V.)
| | - Sandra Alcaraz-Clariana
- Doctoral Program in Biomedicine, University of Córdoba, 14004 Córdoba, Spain; (S.A.-C.); (L.G.-L.)
- Department of Nursing, Pharmacology and Physical Therapy, Faculty of Medicine and Nursing, University of Córdoba, 14004 Córdoba, Spain; (A.P.-R.); (F.A.-S.)
| | - Lourdes García-Luque
- Doctoral Program in Biomedicine, University of Córdoba, 14004 Córdoba, Spain; (S.A.-C.); (L.G.-L.)
| | - Daiana Priscila Rodrigues-de-Souza
- Department of Nursing, Pharmacology and Physical Therapy, Faculty of Medicine and Nursing, University of Córdoba, 14004 Córdoba, Spain; (A.P.-R.); (F.A.-S.)
| | - Francisco Alburquerque-Sendín
- Department of Nursing, Pharmacology and Physical Therapy, Faculty of Medicine and Nursing, University of Córdoba, 14004 Córdoba, Spain; (A.P.-R.); (F.A.-S.)
- Maimonides Biomedical Research Institute of Cordoba (IMIBIC), 14004 Córdoba, Spain
| |
Collapse
|
7
|
Carcreff L, Gerber CN, Paraschiv-Ionescu A, De Coulon G, Aminian K, Newman CJ, Armand S. Walking Speed of Children and Adolescents With Cerebral Palsy: Laboratory Versus Daily Life. Front Bioeng Biotechnol 2020; 8:812. [PMID: 32766230 PMCID: PMC7381141 DOI: 10.3389/fbioe.2020.00812] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2020] [Accepted: 06/24/2020] [Indexed: 12/12/2022] Open
Abstract
The purpose of this pilot study was to compare walking speed, an important component of gait, in the laboratory and daily life, in young individuals with cerebral palsy (CP) and with typical development (TD), and to quantify to what extent gait observed in clinical settings compares to gait in real life. Fifteen children, adolescents and young adults with CP (6 GMFCS I, 2 GMFCS II, and 7 GMFCS III) and 14 with TD were included. They wore 4 synchronized inertial sensors on their shanks and thighs while walking at their spontaneous self-selected speed in the laboratory, and then during 2 week-days and 1 weekend day in their daily environment. Walking speed was computed from shank angular velocity signals using a validated algorithm. The median of the speed distributions in the laboratory and daily life were compared at the group and individual levels using Wilcoxon tests and Spearman's correlation coefficients. The corresponding percentile of daily life speed equivalent to the speed in the laboratory was computed and observed at the group level. Daily-life walking speed was significantly lower compared to the laboratory for the CP group (0.91 [0.58-1.23] m/s vs 1.07 [0.73-1.28] m/s, p = 0.015), but not for TD (1.29 [1.24-1.40] m/s vs 1.29 [1.20-1.40] m/s, p = 0.715). Median speeds correlated highly in CP (p < 0.001, rho = 0.89), but not in TD. In children with CP, 60% of the daily life walking activity was at a slower speed than in-laboratory (corresponding percentile = 60). On the contrary, almost 60% of the daily life activity of TD was at a faster speed than in-laboratory (corresponding percentile = 42.5). Nevertheless, highly heterogeneous behaviors were observed within both populations and within subgroups of GMFCS level. At the group level, children with CP tend to under-perform during natural walking as compared to walking in a clinical environment. The heterogeneous behaviors at the individual level indicate that real-life gait performance cannot be directly inferred from in-laboratory capacity. This emphasizes the importance of completing clinical gait analysis with data from daily life, to better understand the overall function of children with CP.
Collapse
Affiliation(s)
- Lena Carcreff
- Laboratory of Kinesiology Willy Taillard, Geneva University Hospitals, University of Geneva, Geneva, Switzerland
- Pediatric Neurology and Neurorehabilitation Unit, Department of Pediatrics, Lausanne University Hospital, Lausanne, Switzerland
- Laboratory of Movement Analysis and Measurement, Ecole Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
| | - Corinna N. Gerber
- Pediatric Neurology and Neurorehabilitation Unit, Department of Pediatrics, Lausanne University Hospital, Lausanne, Switzerland
| | - Anisoara Paraschiv-Ionescu
- Laboratory of Movement Analysis and Measurement, Ecole Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
| | - Geraldo De Coulon
- Laboratory of Kinesiology Willy Taillard, Geneva University Hospitals, University of Geneva, Geneva, Switzerland
- Pediatric Orthopedics, Geneva University Hospitals, Geneva, Switzerland
| | - Kamiar Aminian
- Laboratory of Movement Analysis and Measurement, Ecole Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
| | - Christopher J. Newman
- Pediatric Neurology and Neurorehabilitation Unit, Department of Pediatrics, Lausanne University Hospital, Lausanne, Switzerland
| | - Stéphane Armand
- Laboratory of Kinesiology Willy Taillard, Geneva University Hospitals, University of Geneva, Geneva, Switzerland
| |
Collapse
|
8
|
Bonnefoy-Mazure A, De Coulon G, Armand S. Self-perceived gait quality in young adults with cerebral palsy. Dev Med Child Neurol 2020; 62:868-873. [PMID: 32162342 DOI: 10.1111/dmcn.14504] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 01/15/2020] [Indexed: 01/01/2023]
Abstract
AIM To explore how patients with cerebral palsy (CP) perceive their gait and evaluate associations between subjective gait perception and: objective gait parameters, endurance, pain, and fatigue. METHOD Sixty-two patients (21 females and 41 males; mean [SD] age 20y [5y 1mo], range 15-29y) performed a clinical gait analysis. Self-selected walking speed, Gait Profile Score, and Gait Variable Score were calculated. Subjective gait perception was assessed with a visual analogue scale using the question: 'On a scale from 0 (worst) to 10 (optimal), how would you describe your walking today?'. A 6-minute walk test (6MWT) measured endurance; the 36-Item Short Form Health Survey (SF-36) evaluated quality of life. T-tests, Pearson correlations, and univariate and multiple linear regression models were used to compare and find associations between the data. RESULTS Overall mean (SD) subjective gait perception was 7.5 (1.8) and was significantly higher for patients in Gross Motor Function Classification System (GMFCS) level I (7.9 [1.5]) than for patients in GMFCS levels II and III (5.9 [2.0]). Positive correlations were found between subjective gait perception and gait scores, walking speed, 6MWT distance, and SF-36 score. Only walking speed was a significant predictor of subjective gait perception. INTERPRETATION Subjective gait perception was influenced by GMFCS level and linked partially with the walking speed. The gait quality did not explain subjective gait perception. It is important to combine subjective and objective gait scores to develop personalized therapeutic goals. WHAT THIS PAPER ADDS Subjective gait perception is influenced by the physical impairment levels of patients with cerebral palsy. Subjective gait perception and objective gait scores are associated. Walking speed is the only predictor of gait perception.
Collapse
Affiliation(s)
- Alice Bonnefoy-Mazure
- Willy Taillard Laboratory of Kinesiology, Geneva University Hospitals and University of Geneva, Geneva, Switzerland
| | - Geraldo De Coulon
- Paediatric Orthopaedic Service, Department of Child and Teenagers, Geneva University Hospitals and University of Geneva, Geneva, Switzerland
| | - Stephane Armand
- Willy Taillard Laboratory of Kinesiology, Geneva University Hospitals and University of Geneva, Geneva, Switzerland
| |
Collapse
|
9
|
Carcreff L, Gerber CN, Paraschiv-Ionescu A, De Coulon G, Newman CJ, Aminian K, Armand S. Comparison of gait characteristics between clinical and daily life settings in children with cerebral palsy. Sci Rep 2020; 10:2091. [PMID: 32034244 PMCID: PMC7005861 DOI: 10.1038/s41598-020-59002-6] [Citation(s) in RCA: 35] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2019] [Accepted: 01/16/2020] [Indexed: 11/09/2022] Open
Abstract
Gait assessments in standardized settings, as part of the clinical follow-up of children with cerebral palsy (CP), may not represent gait in daily life. This study aimed at comparing gait characteristics in laboratory and real life settings on the basis of multiple parameters in children with CP and with typical development (TD). Fifteen children with CP and 14 with TD wore 5 inertial sensors (chest, thighs and shanks) during in-laboratory gait assessments and during 3 days of daily life. Sixteen parameters belonging to 8 distinct domains were computed from the angular velocities and/or accelerations. Each parameter measured in the laboratory was compared to the same parameter measured in daily life for walking bouts defined by a travelled distance similar to the laboratory, using Wilcoxon paired tests and Spearman’s correlations. Most gait characteristics differed between both environments in both groups. Numerous high correlations were found between laboratory and daily life gait parameters for the CP group, whereas fewer correlations were found in the TD group. These results demonstrated that children with CP perform better in clinical settings. Such quantitative evidence may enhance clinicians’ understanding of the gap between capacity and performance in children with CP and improve their decision-making.
Collapse
Affiliation(s)
- Lena Carcreff
- Laboratory of Kinesiology Willy Taillard, Geneva University Hospitals and University of Geneva, 1205, Geneva, Switzerland. .,Pediatric Neurology and Neurorehabilitation Unit, Department of Pediatrics, Lausanne University Hospital, 1011, Lausanne, Switzerland. .,Laboratory of Movement Analysis and Measurement, Ecole Polytechnique Fédérale de Lausanne, 1015, Lausanne, Switzerland.
| | - Corinna N Gerber
- Pediatric Neurology and Neurorehabilitation Unit, Department of Pediatrics, Lausanne University Hospital, 1011, Lausanne, Switzerland
| | - Anisoara Paraschiv-Ionescu
- Laboratory of Movement Analysis and Measurement, Ecole Polytechnique Fédérale de Lausanne, 1015, Lausanne, Switzerland
| | - Geraldo De Coulon
- Laboratory of Kinesiology Willy Taillard, Geneva University Hospitals and University of Geneva, 1205, Geneva, Switzerland.,Pediatric orthopedics, Geneva University Hospitals, 1205, Geneva, Switzerland
| | - Christopher J Newman
- Pediatric Neurology and Neurorehabilitation Unit, Department of Pediatrics, Lausanne University Hospital, 1011, Lausanne, Switzerland
| | - Kamiar Aminian
- Laboratory of Movement Analysis and Measurement, Ecole Polytechnique Fédérale de Lausanne, 1015, Lausanne, Switzerland
| | - Stéphane Armand
- Laboratory of Kinesiology Willy Taillard, Geneva University Hospitals and University of Geneva, 1205, Geneva, Switzerland
| |
Collapse
|
10
|
Concurrent Validity and Reliability of an Inertial Measurement Unit for the Assessment of Craniocervical Range of Motion in Subjects with Cerebral Palsy. Diagnostics (Basel) 2020; 10:diagnostics10020080. [PMID: 32024117 PMCID: PMC7168926 DOI: 10.3390/diagnostics10020080] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2019] [Revised: 01/27/2020] [Accepted: 01/30/2020] [Indexed: 01/29/2023] Open
Abstract
Objective: This study aimed to determine the validity and reliability of Inertial Measurement Units (IMUs) for the assessment of craniocervical range of motion (ROM) in patients with cerebral palsy (CP). Methods: twenty-three subjects with CP and 23 controls, aged between 4 and 14 years, were evaluated on two occasions, separated by 3 to 5 days. An IMU and a Cervical Range of Motion device (CROM) were used to assess craniocervical ROM in the three spatial planes. Validity was assessed by comparing IMU and CROM data using the Pearson correlation coefficient, the paired t-test and Bland–Altman plots. Intra-day and inter-day relative reliability were determined using the Intraclass Correlation Coefficient (ICC). The Standard Error of Measurement (SEM) and the Minimum Detectable Change at a 90% confidence level (MDC90) were obtained for absolute reliability. Results: High correlations were detected between methods in both groups on the sagittal and frontal planes (r > 0.9), although this was reduced in the case of the transverse plane. Bland–Altman plots indicated bias below 5º, although for the range of cervical rotation in the CP group, this was 8.2º. The distance between the limits of agreement was over 23.5º in both groups, except for the range of flexion-extension in the control group. ICCs were higher than 0.8 for both comparisons and groups, except for inter-day comparisons of rotational range in the CP group. Absolute reliability showed high variability, with most SEM below 8.5º, although with worse inter-day results, mainly in CP subjects, with the MDC90 of rotational range achieving more than 20º. Conclusions: IMU application is highly correlated with CROM for the assessment of craniocervical movement in CP and healthy subjects; however, both methods are not interchangeable. The IMU error of measurement can be considered clinically acceptable; however, caution should be taken when this is used as a reference measure for interventions.
Collapse
|
11
|
A Personalized Approach to Improve Walking Detection in Real-Life Settings: Application to Children with Cerebral Palsy. SENSORS 2019; 19:s19235316. [PMID: 31816854 PMCID: PMC6928702 DOI: 10.3390/s19235316] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/31/2019] [Revised: 11/22/2019] [Accepted: 11/29/2019] [Indexed: 12/22/2022]
Abstract
Although many methods have been developed to detect walking by using body-worn inertial sensors, their performances decline when gait patterns become abnormal, as seen in children with cerebral palsy (CP). The aim of this study was to evaluate if fine-tuning an existing walking bouts (WB) detection algorithm by various thresholds, customized at the individual or group level, could improve WB detection in children with CP and typical development (TD). Twenty children (10 CP, 10 TD) wore 4 inertial sensors on their lower limbs during laboratory and out-laboratory assessments. Features extracted from the gyroscope signals recorded in the laboratory were used to tune thresholds of an existing walking detection algorithm for each participant (individual-based personalization: Indiv) or for each group (population-based customization: Pop). Out-of-laboratory recordings were analyzed for WB detection with three versions of the algorithm (i.e., original fixed thresholds and adapted thresholds based on the Indiv and Pop methods), and the results were compared against video reference data. The clinical impact was assessed by quantifying the effect of WB detection error on the estimated walking speed distribution. The two customized Indiv and Pop methods both improved WB detection (higher, sensitivity, accuracy and precision), with the individual-based personalization showing the best results. Comparison of walking speed distribution obtained with the best of the two methods showed a significant difference for 8 out of 20 participants. The personalized Indiv method excluded non-walking activities that were initially wrongly interpreted as extremely slow walking with the initial method using fixed thresholds. Customized methods, particularly individual-based personalization, appear more efficient to detect WB in daily-life settings.
Collapse
|