1
|
Morales-Figueroa C, Linares-Hernández I, Martínez-Miranda V, Teutli-Sequeira EA, Castillo-Suárez LA, Garduño-Pineda L. Electro-galvanic alkalization and treatment of rainwater to obtain drinking water. ENVIRONMENTAL TECHNOLOGY 2024; 45:4116-4130. [PMID: 37490626 DOI: 10.1080/09593330.2023.2241618] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/31/2023] [Accepted: 07/19/2023] [Indexed: 07/27/2023]
Abstract
Rainwater Electro-Galvanic Alkalization (EGA) was performed using copper and magnesium (1:1) electrode. Efficiently removal of pollutants without external energy consumption was carried out, in addition essential ions were dosed for alkalization of rainwater. The optimal system conditions were obtained using response surface methodology (RSM) by considering the following operating variables: flow rate and concentration of the supporting electrolyte (NaCl and CaCl2). Furthermore, the maximum efficiency of nitrate, ammoniacal nitrogen, colour, and turbidity removal was evaluated. The results showed that the response variables were mainly sensitive to the type of supporting electrolyte used and the flow rate. Under experimental conditions of 0.009 M (NaCl) and 20 mL min-1, the removal rate was 74.19%, 72.49%, and 81.43% for nitrates, colour, and turbidity, respectively, and the lowest concentration of ammoniacal nitrogen (0.99 mg L - 1 ) was obtained. The kinetic models for nitrate and colour were fitted to zero-order models with k = 0.33 mg L - 1 mi n - 1 and k = 0.933 Pt - Co , respectively. In addition, turbidity was fitted to a first-order model ( k = 0.1661 mi n - 1 ) , and ammoniacal nitrogen was fitted to a second-order model ( k = 0.0217 L m g - 1 mi n - 1 ) . The concentration increases of minerals such as Ca and Mg, which rises the rainwater alkalinity after treatment (pH shift from 6.1 to 8.91), was determined by inductively coupled plasma (ICP) analysis.
Collapse
Affiliation(s)
- Cristina Morales-Figueroa
- Facultad de Química, Unidad Colón, Toluca de Lerdo, México
- Instituto Interamericano de Tecnología y Ciencias del Agua (IITCA), Unidad San Cayetano, Universidad Autónoma del Estado de México, Toluca, México
| | - Ivonne Linares-Hernández
- Instituto Interamericano de Tecnología y Ciencias del Agua (IITCA), Unidad San Cayetano, Universidad Autónoma del Estado de México, Toluca, México
| | - Verónica Martínez-Miranda
- Instituto Interamericano de Tecnología y Ciencias del Agua (IITCA), Unidad San Cayetano, Universidad Autónoma del Estado de México, Toluca, México
| | | | - Luis Antonio Castillo-Suárez
- Instituto Interamericano de Tecnología y Ciencias del Agua (IITCA), Unidad San Cayetano, Universidad Autónoma del Estado de México, Toluca, México
- Advanced Oxidation Processes Department, Cátedras COMECYT, Toluca, México
| | - Laura Garduño-Pineda
- Analytics Chemistry Department, Tecnológico de Estudios Superiores de Jocotitlán (TESJo), Jocotitlán, México
| |
Collapse
|
2
|
Pelayo D, Hernández-Pellón A, Santos G, Rumayor M, Ortiz I, Rivero MJ. Performance of high-efficiency UV-C LEDs in water disinfection: Experimental, life cycle assessment, and economic analysis of different operational scenarios. JOURNAL OF ENVIRONMENTAL MANAGEMENT 2024; 364:121442. [PMID: 38870793 DOI: 10.1016/j.jenvman.2024.121442] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/12/2024] [Revised: 05/29/2024] [Accepted: 06/07/2024] [Indexed: 06/15/2024]
Abstract
The widespread use of low or medium pressure mercury lamps in UV-C water disinfection should consider recent advances in UV-C LED lamps that offer a more sustainable approach and avoid its main drawbacks. The type of water and the mode of operation are critical when deciding on the treatment technology to be used. Therefore, this study investigates the potential application of UV-C LED disinfection technology in terms of kinetics, environmental assessment, and economic analysis for two scenarios: the continuous disinfection of a wastewater treatment plant (WWTP), and disinfection of harvested rainwater (RWH) in a residential household that operates intermittently. Experiments are conducted using both the new UV-C LED system and the conventional mercury lamp to disinfect real wastewater. Removal of total coliforms and Escherichia coli bacteria, with concentrations of approximately 105 and 104 CFU per 100 mL has been followed to assess the performance of both types of UV-C lamps. The experimental study provides kinetic parameters that have been further used in the environmental assessment conducted from a life cycle perspective. Additionally, considering the significant role of electricity consumption, a preliminary economic analysis has been conducted. The results indicate that first-order kinetic constants of pathogens removal with UV-C LEDs achieve 1.4 times higher values than Hg lamp. Regarding the environmental and economic assessment, for disinfection systems operating continuously, LEDs result in environmental impacts 5 times higher than Hg lamp in most categories, indicating that Hg lamps offer a viable option both from economic and environmental point of view. However, for installations with intermittent operation, LEDs emerge as the most competitive alternative, due to their ability to be turned on and off without affecting their lifespan. This study shows that UV-C LED lamps hold promise to replace conventional mercury lamps in a near future.
Collapse
Affiliation(s)
- Deva Pelayo
- Departamento de Ingeniería Química y Biomolecular, Universidad de Cantabria, Avda. Los Castros, s/n, 39005 Santander, Cantabria, Spain
| | - Ana Hernández-Pellón
- APRIA Systems, S.L., Bussines park of Morero, Parcel P-2-12, Industrial Unit 1-Door 5, 39611 Guarnizo, Cantabria, Spain
| | - Germán Santos
- APRIA Systems, S.L., Bussines park of Morero, Parcel P-2-12, Industrial Unit 1-Door 5, 39611 Guarnizo, Cantabria, Spain
| | - Marta Rumayor
- Departamento de Ingeniería Química y Biomolecular, Universidad de Cantabria, Avda. Los Castros, s/n, 39005 Santander, Cantabria, Spain
| | - Inmaculada Ortiz
- Departamento de Ingeniería Química y Biomolecular, Universidad de Cantabria, Avda. Los Castros, s/n, 39005 Santander, Cantabria, Spain
| | - María J Rivero
- Departamento de Ingeniería Química y Biomolecular, Universidad de Cantabria, Avda. Los Castros, s/n, 39005 Santander, Cantabria, Spain.
| |
Collapse
|
3
|
Adeel M, Granata V, Carapella G, Rizzo L. Effect of microplastics on urban wastewater disinfection and impact on effluent reuse: Sunlight/H 2O 2 vs solar photo-Fenton at neutral pH. JOURNAL OF HAZARDOUS MATERIALS 2024; 465:133102. [PMID: 38070270 DOI: 10.1016/j.jhazmat.2023.133102] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/25/2023] [Revised: 11/17/2023] [Accepted: 11/25/2023] [Indexed: 02/08/2024]
Abstract
The interference of three types of microplastics (MPs) on the inactivation of Escherichia coli (E. coli) by advanced oxidation processes (AOPs) (namely, sunlight/H2O2 and solar photo-Fenton (SPF) with Ethylenediamine-N,N'-disuccinic acid (EDDS)), in real secondary treated urban wastewater was investigated for the first time. Inactivation by sunlight/H2O2 treatment decreased as MPs concentration and H2O2 dose were increased. Noteworthy, an opposite behaviour was observed for SPF process where inactivation increased as MPs concentration was increased. Biofilm formation and microbial attachment on surfaces of post-treated MPs were observed on polyethylene (PE) and polyvinyl chloride (PVC) MPs by field emission scanning electron microscopy. In presence of PE MPs, a complete inactivation of E. Coli was achieved by SPF with EDDS (Fe:EDDS = 1:2) after 90 min treatment unlike of sunlight/H2O2 treatment (∼4.0 log reduction, 40 mg/L H2O2 dose, 90 min treatment). The lower efficiency of sunlight/H2O2 process could be attributed to the blocking/scattering effect of MPs on sunlight, which finally reduced the intracellular photo Fenton effect. A reduced E. coli regrowth was observed in presence of MPs. SPF (Fe:EDDS = 1:1) with PE MPs was less effective in controlling bacterial regrowth (∼120 CFU/100 mL) than sunlight/H2O2 (∼10 CFU/100 mL) after 48 h of post-treatment. These results provide useful information about possible interference of MPs on urban wastewater disinfection by solar driven AOPs and possible implications for effluent reuse.
Collapse
Affiliation(s)
- Mister Adeel
- Water Science and Technology (WaSTe) Group, Department of Civil Engineering, University of Salerno, Via Giovanni Paolo II 132, 84084 Fisciano, SA, Italy
| | - Veronica Granata
- Department of Physics "E.R. Caianiello", University of Salerno, Via Giovanni Paolo II 132, 84084 Fisciano, SA, Italy
| | - Giovanni Carapella
- Department of Physics "E.R. Caianiello", University of Salerno, Via Giovanni Paolo II 132, 84084 Fisciano, SA, Italy
| | - Luigi Rizzo
- Water Science and Technology (WaSTe) Group, Department of Civil Engineering, University of Salerno, Via Giovanni Paolo II 132, 84084 Fisciano, SA, Italy.
| |
Collapse
|
4
|
La Manna P, De Carluccio M, Oliva G, Vigliotta G, Rizzo L. Urban wastewater disinfection by iron chelates mediated solar photo-Fenton: Effects on seven pathogens and antibiotic resistance transfer potential. WATER RESEARCH 2024; 249:120966. [PMID: 38070340 DOI: 10.1016/j.watres.2023.120966] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/19/2023] [Revised: 10/25/2023] [Accepted: 12/01/2023] [Indexed: 01/03/2024]
Abstract
The effects of solar photo-Fenton (SPF) process mediated by the iron chelate Fe3+ imminodisuccinic acid (Fe:IDS) on both the inactivation of seven relevant pathogens and the potential for antibiotic resistance transfer (degradation of antibiotic resistance genes (ARGs) and after treatment regrowth), in real secondary treated urban wastewater, were investigated for the first time. A comparison with results obtained by sunlight/H2O2 process and Fe3+ ethylenediaminedisuccinic acid (Fe:EDDS) SPF was also carried out. ARGs were quantified by polymerase chain reaction (PCR) in samples before and after (3 h) the treatment. The persistence of the selected pathogens and ARGs was also evaluated in regrowth tests (72 h) under environmentally mimicking conditions. Fe:IDS SPF resulted to be more effective (from 1.4 log removal for Staphylococcus spp. to 4.3 log removal for Escherichia coli) than Fe:EDDS SPF (from 0.8 log removal for Pseudomonas aeruginosa to 2.0 log removal for Total coliphages) and sunlight/H2O2 (from 1.2 log removal for Clostridium perfringens to 3.3 log removal for E. coli) processes for the seven pathogens investigated. Potential pathogens regrowth was also severely affected, as no substantial regrowth was observed, both in presence and absence of catalase. A similar trend was observed for ARGs removal too (until 0.001 fold change expression for qnrS after 3 h). However, a poor effect and a slight increase in fold change was observed after treatment especially for gyrA, mefA and intl1. Overall, the effect of the investigated processes on ARGs was found to be ARG dependent. Noteworthy, coliphages can regrow after sunlight/H2O2 treatment unlike SPF processes, increasing the risk of antibiotic resistance transfer by transduction mechanism. In conclusion, Fe:IDS SPF is an attractive solution for tertiary treatment of urban wastewater in small wastewater treatment plants as it can provide effective disinfection and a higher protection against antibiotic resistance transfer than the other investigated processes.
Collapse
Affiliation(s)
- Pellegrino La Manna
- Water Science and Technology group (WaSTe), Department of Civil Engineering, University of Salerno, Via Giovanni Paolo II 132, 84084 Fisciano, SA, Italy
| | - Marco De Carluccio
- Water Science and Technology group (WaSTe), Department of Civil Engineering, University of Salerno, Via Giovanni Paolo II 132, 84084 Fisciano, SA, Italy
| | - Gianmaria Oliva
- Department of Chemistry and Biology, University of Salerno, Via Giovanni Paolo II 132, 84084 Fisciano, SA, Italy
| | - Giovanni Vigliotta
- Department of Chemistry and Biology, University of Salerno, Via Giovanni Paolo II 132, 84084 Fisciano, SA, Italy
| | - Luigi Rizzo
- Water Science and Technology group (WaSTe), Department of Civil Engineering, University of Salerno, Via Giovanni Paolo II 132, 84084 Fisciano, SA, Italy.
| |
Collapse
|
5
|
Wang L, Mai Y, Li S, Shu L, Fang J. Efficient inactivation of amoeba spores and their intraspore bacteria by solar/chlorine: Kinetics and mechanisms. WATER RESEARCH 2023; 242:120288. [PMID: 37419027 DOI: 10.1016/j.watres.2023.120288] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/21/2023] [Revised: 06/21/2023] [Accepted: 06/28/2023] [Indexed: 07/09/2023]
Abstract
Amoebae are widespread in water and serve as environment vectors for pathogens, which may threaten public health. This study evaluated the inactivation of amoeba spores and their intraspore bacteria by solar/chlorine. Dictyostelium discoideum and Burkholderia agricolaris B1qs70 were selected as model amoebae and intraspore bacteria, respectively. Compared to solar irradiation and chlorine, solar/chlorine enhanced the inactivation of amoeba spores and intraspore bacteria, with 5.1 and 5.2-log reduction at 20 min, respectively. The enhancement was similar in real drinking water by solar/chlorine under natural sunlight. However, the spore inactivation decreased to 2.97-log by 20 min solar/chlorine under oxygen-free condition, indicating that ozone played a crucial role in the spore inactivation, as also confirmed by the scavenging test using tert‑butanol to scavenge the ground-state atomic oxygen (O(3P)) as a ozone precursor. Moreover, solar/chlorine induced the shape destruction and structural collapse of amoeba spores by scanning electron microscopy. As for intraspore bacteria, their inactivation was likely ascribed to endogenous reactive oxygen species. As pH increased from 5.0 to 9.0, the inactivation of amoeba spores decreased, whereas that of intraspore bacteria was similar at pH 5.0 and 6.5 during solar/chlorine treatment. This study first reports the efficient inactivation of amoeba spores and their intraspore pathogenic bacteria by solar/chlorine in drinking water.
Collapse
Affiliation(s)
- Liping Wang
- Guangdong Provincial Key Laboratory of Environmental Pollution Control and Remediation Technology, School of Environmental Science and Engineering, Sun Yat-Sen University, Guangzhou 510275 China
| | - Yingwen Mai
- Guangdong Provincial Key Laboratory of Environmental Pollution Control and Remediation Technology, School of Environmental Science and Engineering, Sun Yat-Sen University, Guangzhou 510275 China
| | - Shenzhou Li
- Guangdong Provincial Key Laboratory of Environmental Pollution Control and Remediation Technology, School of Environmental Science and Engineering, Sun Yat-Sen University, Guangzhou 510275 China
| | - Longfei Shu
- Guangdong Provincial Key Laboratory of Environmental Pollution Control and Remediation Technology, School of Environmental Science and Engineering, Sun Yat-Sen University, Guangzhou 510275 China.
| | - Jingyun Fang
- Guangdong Provincial Key Laboratory of Environmental Pollution Control and Remediation Technology, School of Environmental Science and Engineering, Sun Yat-Sen University, Guangzhou 510275 China.
| |
Collapse
|
6
|
Yuan M, Xue J, Li J, Ma S, Wang M. PCN-222/Ag2O-Ag p-n heterojunction modified fabric as recyclable photocatalytic platform for boosting bacteria inactivation and organic pollutant degradation. Colloids Surf A Physicochem Eng Asp 2022. [DOI: 10.1016/j.colsurfa.2022.130474] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
|
7
|
Blanco-Canella P, Lama G, Sanromán MA, Pazos M. Disinfection through Advance Oxidation Processes: Optimization and Application on Real Wastewater Matrices. TOXICS 2022; 10:512. [PMID: 36136477 PMCID: PMC9501268 DOI: 10.3390/toxics10090512] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/09/2022] [Revised: 08/19/2022] [Accepted: 08/25/2022] [Indexed: 06/16/2023]
Abstract
Disinfection is an essential and significant process for water treatment to protect the environment and human beings from pathogenic infections. In this study, disinfection through the generation of hydroxyl (Fenton process (FP)) and sulfate (Fenton-like process (FLP)) radicals was validated and optimized. The optimization was carried out in synthetic water through an experimental design methodology using the bacteria Escherichia coli as a model microorganism. Different variables were evaluated in both processes: precursor concentration (peroxymonosulfate (PMS) and H2O2), catalyst concentration (Fe+2), and pH in the Fenton process. After that, the optimized conditions (FP: 132.36 mM H2O2, 0.56 mM Fe+2 and 3.26 pH; FLP: 3.82 mM PMS and 0.40 mM Fe+2) were applied to real matrices from wastewater treatment plants. The obtained results suggest that both processes are promising for disinfection due to the high oxidant power of hydroxyl and sulfate radicals.
Collapse
|
8
|
Berruti I, Nahim-Granados S, Abeledo-Lameiro MJ, Oller I, Polo-López MI. Recent advances in solar photochemical processes for water and wastewater disinfection. CHEMICAL ENGINEERING JOURNAL ADVANCES 2022. [DOI: 10.1016/j.ceja.2022.100248] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022] Open
|
9
|
Ferreira MPS, Santos PSM, Duarte AC. Oxidation of small aromatic compounds in rainwater by UV/H 2O 2: Optimization by response surface methodology. THE SCIENCE OF THE TOTAL ENVIRONMENT 2022; 815:152857. [PMID: 34995602 DOI: 10.1016/j.scitotenv.2021.152857] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/07/2021] [Revised: 12/28/2021] [Accepted: 12/29/2021] [Indexed: 06/14/2023]
Abstract
The presence of aromatic compounds in rainwater is a matter of concern, mainly when the use of rainwater in buildings is intended. The present work aimed to assess the oxidation of a mixture of small aromatic compounds (benzoic, 3,5-dihydroxybenzoic and syringic acids) in rainwater by the UV/H2O2 process, and the possibility of its optimization by the response surface methodology. The extent of oxidation was assessed by ultraviolet-visible and molecular fluorescence spectroscopies. During the oxidation of the mixture new chromophoric compounds were formed at an initial stage, but they were then degraded at a later stage. The increase of the H2O2 concentration, resulted in a higher extent of oxidation, while the initial pH value showed no influence in the oxidation of the mixture. The optimization of the oxidation was performed using the uniform design with the factors: initial H2O2 concentration, initial pH, and reaction time. The response surface model found, through the best subsets regression, described the extent of oxidation as function of the following variables: initial H2O2 concentration and reaction time, interaction between them, and also their respective quadratic forms. The optimal conditions, the lowest H2O2 concentration (3.1 mM) for a selected maximum reaction time (4 h), were applied to rainwater samples spiked with the mixture of contaminants and resulted in an extent of oxidation higher than 99.5%, validating the application of the model to real samples. Therefore, the UV/H2O2 process coupled to its optimization via response surface methodology may be an alternative for rainwater treatment in buildings.
Collapse
Affiliation(s)
- Mónica P S Ferreira
- CESAM & Department of Chemistry, University of Aveiro, Campus Universitário de Santiago, 3810-193 Aveiro, Portugal
| | - Patrícia S M Santos
- CESAM & Department of Chemistry, University of Aveiro, Campus Universitário de Santiago, 3810-193 Aveiro, Portugal.
| | - Armando C Duarte
- CESAM & Department of Chemistry, University of Aveiro, Campus Universitário de Santiago, 3810-193 Aveiro, Portugal
| |
Collapse
|