1
|
Herrera-Domínguez M, Morales-Luna G, Mahlknecht J, Cheng Q, Aguilar-Hernández I, Ornelas-Soto N. Optical Biosensors and Their Applications for the Detection of Water Pollutants. BIOSENSORS 2023; 13:bios13030370. [PMID: 36979582 PMCID: PMC10046542 DOI: 10.3390/bios13030370] [Citation(s) in RCA: 9] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/31/2023] [Revised: 03/01/2023] [Accepted: 03/02/2023] [Indexed: 05/14/2023]
Abstract
The correct detection and quantification of pollutants in water is key to regulating their presence in the environment. Biosensors offer several advantages, such as minimal sample preparation, short measurement times, high specificity and sensibility and low detection limits. The purpose of this review is to explore the different types of optical biosensors, focusing on their biological elements and their principle of operation, as well as recent applications in the detection of pollutants in water. According to our literature review, 33% of the publications used fluorescence-based biosensors, followed by surface plasmon resonance (SPR) with 28%. So far, SPR biosensors have achieved the best results in terms of detection limits. Although less common (22%), interferometers and resonators (4%) are also highly promising due to the low detection limits that can be reached using these techniques. In terms of biological recognition elements, 43% of the published works focused on antibodies due to their high affinity and stability, although they could be replaced with molecularly imprinted polymers. This review offers a unique compilation of the most recent work in the specific area of optical biosensing for water monitoring, focusing on both the biological element and the transducer used, as well as the type of target contaminant. Recent technological advances are discussed.
Collapse
Affiliation(s)
- Marcela Herrera-Domínguez
- Tecnológico de Monterrey, Escuela de Ingeniería y Ciencias, Ave. Eugenio Garza Sada 2501, Monterrey 64849, Mexico
| | - Gesuri Morales-Luna
- Departamento de Física y Matemáticas, Universidad Iberoamericana, Prolongación Paseo de la Reforma 880, Mexico City 01219, Mexico
| | - Jürgen Mahlknecht
- Tecnológico de Monterrey, Escuela de Ingeniería y Ciencias, Ave. Eugenio Garza Sada 2501, Monterrey 64849, Mexico
| | - Quan Cheng
- Department of Chemistry, University of California, Riverside, CA 92521, USA
| | - Iris Aguilar-Hernández
- Tecnológico de Monterrey, Escuela de Ingeniería y Ciencias, Ave. Eugenio Garza Sada 2501, Monterrey 64849, Mexico
- Correspondence: (I.A.-H.); (N.O.-S.)
| | - Nancy Ornelas-Soto
- Tecnológico de Monterrey, Escuela de Ingeniería y Ciencias, Ave. Eugenio Garza Sada 2501, Monterrey 64849, Mexico
- Correspondence: (I.A.-H.); (N.O.-S.)
| |
Collapse
|
2
|
Machine learning and metabolic modelling assisted implementation of a novel process analytical technology in cell and gene therapy manufacturing. Sci Rep 2023; 13:834. [PMID: 36646795 PMCID: PMC9842697 DOI: 10.1038/s41598-023-27998-2] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2022] [Accepted: 01/11/2023] [Indexed: 01/18/2023] Open
Abstract
Process analytical technology (PAT) has demonstrated huge potential to enable the development of improved biopharmaceutical manufacturing processes by ensuring the reliable provision of quality products. However, the complexities associated with the manufacture of advanced therapy medicinal products have resulted in a slow adoption of PAT tools into industrial bioprocessing operations, particularly in the manufacture of cell and gene therapy products. Here we describe the applicability of a novel refractometry-based PAT system (Ranger system), which was used to monitor the metabolic activity of HEK293T cell cultures during lentiviral vector (LVV) production processes in real time. The PAT system was able to rapidly identify a relationship between bioreactor pH and culture metabolic activity and this was used to devise a pH operating strategy that resulted in a 1.8-fold increase in metabolic activity compared to an unoptimised bioprocess in a minimal number of bioreactor experiments; this was achieved using both pre-programmed and autonomous pH control strategies. The increased metabolic activity of the cultures, achieved via the implementation of the PAT technology, was not associated with increased LVV production. We employed a metabolic modelling strategy to elucidate the relationship between these bioprocess level events and HEK293T cell metabolism. The modelling showed that culturing of HEK293T cells in a low pH (pH 6.40) environment directly impacted the intracellular maintenance of pH and the intracellular availability of oxygen. We provide evidence that the elevated metabolic activity was a response to cope with the stress associated with low pH to maintain the favourable intracellular conditions, rather than being indicative of a superior active state of the HEK293T cell culture resulting in enhanced LVV production. Forecasting strategies were used to construct data models which identified that the novel PAT system not only had a direct relationship with process pH but also with oxygen availability; the interaction and interdependencies between these two parameters had a direct effect on the responses observed at the bioprocess level. We present data which indicate that process control and intervention using this novel refractometry-based PAT system has the potential to facilitate the fine tuning and rapid optimisation of the production environment and enable adaptive process control for enhanced process performance and robustness.
Collapse
|
3
|
Gerdan Z, Saylan Y, Denizli A. Recent Advances of Optical Sensors for Copper Ion Detection. MICROMACHINES 2022; 13:1298. [PMID: 36014218 PMCID: PMC9413819 DOI: 10.3390/mi13081298] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/04/2022] [Revised: 07/30/2022] [Accepted: 08/08/2022] [Indexed: 06/15/2023]
Abstract
A trace element copper (Cu2+) ion is the third most plentiful metal ion that necessary for all living organisms and playing a critical role in several processes. Nonetheless, according to cellular needs, deficient or excess Cu2+ ion cause various diseases. For all these reasons, optical sensors have been focused rapid Cu2+ ion detection in real-time with high selectivity and sensitivity. Optical sensors can measure fluorescence in the refractive index-adsorption from the relationships between light and matter. They have gained great attention in recent years due to the excellent advantages of simple and naked eye recognition, real-time detection, low cost, high specificity against analytes, a quick response, and the need for less complex equipment in analysis. This review aims to show the significance of Cu2+ ion detection and electively current trends in optical sensors. The integration of optical sensors with different systems, such as microfluidic systems, is mentioned, and their latest studies in medical and environmental applications also are depicted. Conclusions and future perspectives on these advances is added at the end of the review.
Collapse
|
4
|
Polat EO, Cetin MM, Tabak AF, Bilget Güven E, Uysal BÖ, Arsan T, Kabbani A, Hamed H, Gül SB. Transducer Technologies for Biosensors and Their Wearable Applications. BIOSENSORS 2022; 12:bios12060385. [PMID: 35735533 PMCID: PMC9221076 DOI: 10.3390/bios12060385] [Citation(s) in RCA: 23] [Impact Index Per Article: 11.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/28/2022] [Revised: 05/16/2022] [Accepted: 05/27/2022] [Indexed: 05/17/2023]
Abstract
The development of new biosensor technologies and their active use as wearable devices have offered mobility and flexibility to conventional western medicine and personal fitness tracking. In the development of biosensors, transducers stand out as the main elements converting the signals sourced from a biological event into a detectable output. Combined with the suitable bio-receptors and the miniaturization of readout electronics, the functionality and design of the transducers play a key role in the construction of wearable devices for personal health control. Ever-growing research and industrial interest in new transducer technologies for point-of-care (POC) and wearable bio-detection have gained tremendous acceleration by the pandemic-induced digital health transformation. In this article, we provide a comprehensive review of transducers for biosensors and their wearable applications that empower users for the active tracking of biomarkers and personal health parameters.
Collapse
|
5
|
Bedi N, Srivastava DK, Srivastava A, Mahapatra S, Dkhar DS, Chandra P, Srivastava A. Marine Biological Macromolecules as Matrix Material for Biosensor fabrication. Biotechnol Bioeng 2022; 119:2046-2063. [PMID: 35470439 DOI: 10.1002/bit.28122] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2022] [Revised: 04/19/2022] [Accepted: 04/23/2022] [Indexed: 11/06/2022]
Abstract
The Ocean covers two-third of our planet and has great biological heterogeneity. Marine organisms like algae, vertebrates, invertebrates, and microbes are known to provide many natural products with biological activities as well as potent sources of biomaterials for therapeutic, biomedical, biosensors, and climate stabilization. Over the years, the field of biosensors have gained huge attention due to their extraordinary ability to provide early disease diagnosis, rapid detection of various molecules and substances along with long term monitoring. This review aims to focus on the properties and employment of various biomaterials (Carbohydrate polymers, proteins, polyacids etc) of marine origin such as Alginate, Chitin, Chitosan, Fucoidan, Carrageenan, Chondroitin Sulfate (CS), Hyaluronic acid (HA), Collagen, marine pigments, marine nanoparticles, Hydroxyapatite (HAp), Biosilica, lectins, and marine whole cell in the design and development of biosensors. Further, this review also covers the source of such marine biomaterials and their promising evolution in the fabrication of biosensors that are potent to be employed in the biomedical, environmental science and agricultural sciences domains. The use of such fabricated biosensors harness the system with excellent specificity, selectivity, biocompatibility, thermally stable and minimal cost advantages. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Namita Bedi
- Amity Institute of Biotechnology, Amity University Uttar Pradesh, Sector 125, Noida, India
| | | | - Arti Srivastava
- Amity Institute of Biotechnology, Amity University Uttar Pradesh, Sector 125, Noida, India
| | - Supratim Mahapatra
- Laboratory of Bio-Physio Sensors and Nanobiotechnology, School of Biochemical Engineering, Indian Institute of Technology (BHU) Varanasi, Varanasi, Uttar Pradesh, India
| | - Daphika S Dkhar
- Laboratory of Bio-Physio Sensors and Nanobiotechnology, School of Biochemical Engineering, Indian Institute of Technology (BHU) Varanasi, Varanasi, Uttar Pradesh, India
| | - Pranjal Chandra
- Laboratory of Bio-Physio Sensors and Nanobiotechnology, School of Biochemical Engineering, Indian Institute of Technology (BHU) Varanasi, Varanasi, Uttar Pradesh, India
| | - Ashutosh Srivastava
- Amity Institute of Biotechnology, Amity University Uttar Pradesh, Sector 125, Noida, India.,Amity Institute of Marine Science and Technology, Amity University Uttar Pradesh, Sector 125, Noida, India
| |
Collapse
|
6
|
Dudanova I. Biosensors for Studying Neuronal Proteostasis. Front Mol Neurosci 2022; 15:829365. [PMID: 35345600 PMCID: PMC8957107 DOI: 10.3389/fnmol.2022.829365] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2021] [Accepted: 01/31/2022] [Indexed: 01/18/2023] Open
Abstract
Cellular health depends on the integrity and functionality of the proteome. Each cell is equipped with a protein quality control machinery that maintains protein homeostasis (proteostasis) by helping proteins adopt and keep their native structure, and ensuring the degradation of damaged proteins. Postmitotic cells such as neurons are especially vulnerable to disturbances of proteostasis. Defects of protein quality control occur in aging and have been linked to several disorders, including neurodegenerative diseases. However, the exact nature and time course of such disturbances in the context of brain diseases remain poorly understood. Sensors that allow visualization and quantitative analysis of proteostasis capacity in neurons are essential for gaining a better understanding of disease mechanisms and for testing potential therapies. Here, I provide an overview of available biosensors for assessing the functionality of the neuronal proteostasis network, point out the advantages and limitations of different sensors, and outline their potential for biological discoveries and translational applications.
Collapse
|
7
|
Botewad SN, Gaikwad DK, Girhe NB, Pawar PP. Ultrasensitive polyaniline
‐
nickel oxide cladding modified with urease immobilized intrinsic optical fiber urea biosensor. POLYM ADVAN TECHNOL 2022. [DOI: 10.1002/pat.5504] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Affiliation(s)
- Sunil N. Botewad
- Department of Physics Dr. Babasaheb Ambedkar Marathwada University Aurangabad Maharashtra India
| | | | - Nitin B. Girhe
- Department of Physics Jawahar Science, Commerce and Arts College Andoor Tuljapur Maharashtra India
| | - Pravina P. Pawar
- Department of Physics Dr. Babasaheb Ambedkar Marathwada University Aurangabad Maharashtra India
| |
Collapse
|
8
|
Adampourezare M, Hasanzadeh M, Seidi F. Optical bio-sensing of DNA methylation analysis: an overview of recent progress and future prospects. RSC Adv 2022; 12:25786-25806. [PMID: 36199327 PMCID: PMC9460980 DOI: 10.1039/d2ra03630d] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2022] [Accepted: 09/03/2022] [Indexed: 12/02/2022] Open
Abstract
DNA methylation as one of the most important epigenetic modifications has a critical role in regulating gene expression and drug resistance in treating diseases such as cancer. Therefore, the detection of DNA methylation in the early stages of cancer plays an essential role in disease diagnosis. The majority of routine methods to detect DNA methylation are very tedious and costly. Therefore, designing easy and sensitive methods to detect DNA methylation directly and without the need for molecular methods is a hot topic issue in bioscience. Here we provide an overview on the optical biosensors (including fluorescence, FRET, SERs, colorimetric) that have been applied to detect the DNA methylation. In addition, various types of labeled and label-free reactions along with the application of molecular methods and optical biosensors have been surveyed. Also, the effect of nanomaterials on the sensitivity of detection methods is discussed. Furthermore, a comprehensive overview of the advantages and disadvantages of each method are provided. Finally, the use of microfluidic devices in the evaluation of DNA methylation and DNA damage analysis based on smartphone detection has been discussed. Here, we provide an overview on the optical biosensors (including fluorescence, FRET, SERs, colorimetric) that have been applied to detect the DNA methylation.![]()
Collapse
Affiliation(s)
- Mina Adampourezare
- Department of Biology, Faculty of Natural Science, University of Tabriz, Tabriz, Iran
- Pharmaceutical Analysis Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Mohammad Hasanzadeh
- Pharmaceutical Analysis Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
- Nutrition Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Farzad Seidi
- Jiangsu Co-Innovation Center for Efficient Processing and Utilization of Forest Resources and International Innovation Center for Forest Chemicals and Materials, Nanjing Forestry University, Nanjing 210037, China
| |
Collapse
|
9
|
Rahman M, Sampad MJN, Hawkins A, Schmidt H. Recent advances in integrated solid-state nanopore sensors. LAB ON A CHIP 2021; 21:3030-3052. [PMID: 34137407 PMCID: PMC8372664 DOI: 10.1039/d1lc00294e] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
The advent of single-molecule probing techniques has revolutionized the biomedical and life science fields and has spurred the development of a new class of labs-on-chip based on powerful biosensors. Nanopores represent one of the most recent and most promising single molecule sensing paradigms that is seeing increased chip-scale integration for improved convenience and performance. Due to their physical structure, nanopores are highly sensitive, require low sample volume, and offer label-free, amplification-free, high-throughput real-time detection and identification of biomolecules. Over the last 25 years, nanopores have been extensively employed to detect a variety of biomolecules with a growing range of applicatons ranging from nucleic acid sequencing to ultrasensitive diagnostics to single-molecule biophysics. Nanopores, in particular those in solid-state membranes, also have the potential for integration with other technologies such as optics, plasmonics, microfluidics, and optofluidics to perform more complex tasks for an ever-expanding demand. A number of breakthrough results using integrated nanopore platforms have already been reported, and more can be expected as nanopores remain the focus of innovative research and are finding their way into commercial instruments. This review provides an overview of different aspects and challenges of nanopore technology with a focus on chip-scale integration of solid-state nanopores for biosensing and bioanalytical applications.
Collapse
Affiliation(s)
- Mahmudur Rahman
- School of Engineering, University of California Santa Cruz, 1156 High Street, Santa Cruz, CA, 95064 USA. and Dhaka University of Engineering & Technology, Gazipur, Bangladesh
| | | | - Aaron Hawkins
- ECEn Department, Brigham Young University, 459 Clyde Building, Provo, UT, 84602 USA
| | - Holger Schmidt
- School of Engineering, University of California Santa Cruz, 1156 High Street, Santa Cruz, CA, 95064 USA.
| |
Collapse
|
10
|
Bakh NA, Gong X, Lee MA, Jin X, Koman VB, Park M, Nguyen FT, Strano MS. Transcutaneous Measurement of Essential Vitamins Using Near-Infrared Fluorescent Single-Walled Carbon Nanotube Sensors. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2021; 17:e2100540. [PMID: 34176216 DOI: 10.1002/smll.202100540] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/27/2021] [Revised: 04/29/2021] [Indexed: 06/13/2023]
Abstract
Vitamins such as riboflavin and ascorbic acid are frequently utilized in a range of biomedical applications as drug delivery targets, fluidic tracers, and pharmaceutical excipients. Sensing these biochemicals in the human body has the potential to significantly advance medical research and clinical applications. In this work, a nanosensor platform consisting of single-walled carbon nanotubes (SWCNTs) with nanoparticle corona phases engineered to allow for the selective molecular recognition of ascorbic acid and riboflavin, is developed. The study provides a methodological framework for the implementation of colloidal SWCNT nanosensors in an intraperitoneal SKH1-E murine model by addressing complications arising from tissue absorption and scattering, mechanical perturbations, as well as sensor diffusion and interactions with the biological environment. Nanosensors are encapsulated in a polyethylene glycol diacrylate hydrogel and a diffusion model is utilized to validate analyte transport and sensor responses to local concentrations at the boundary. Results are found to be reproducible and stable after exposure to 10% mouse serum even after three days of in vivo implantation. A geometrical encoding scheme is used to reference sensor pairs, correcting for in vivo optical and mechanical artifacts, resulting in an order of magnitude improvement of p-value from 0.084 to 0.003 during analyte sensing.
Collapse
Affiliation(s)
- Naveed A Bakh
- Department of Chemical Engineering, Massachusetts Institute of Technology, 77 Massachusetts Ave., Cambridge, MA, 02139, USA
| | - Xun Gong
- Department of Chemical Engineering, Massachusetts Institute of Technology, 77 Massachusetts Ave., Cambridge, MA, 02139, USA
| | - Michael A Lee
- Department of Chemical Engineering, Massachusetts Institute of Technology, 77 Massachusetts Ave., Cambridge, MA, 02139, USA
| | - Xiaojia Jin
- Department of Chemical Engineering, Massachusetts Institute of Technology, 77 Massachusetts Ave., Cambridge, MA, 02139, USA
| | - Volodymyr B Koman
- Department of Chemical Engineering, Massachusetts Institute of Technology, 77 Massachusetts Ave., Cambridge, MA, 02139, USA
| | - Minkyung Park
- Department of Chemical Engineering, Massachusetts Institute of Technology, 77 Massachusetts Ave., Cambridge, MA, 02139, USA
| | - Freddy T Nguyen
- Department of Chemical Engineering, Massachusetts Institute of Technology, 77 Massachusetts Ave., Cambridge, MA, 02139, USA
| | - Michael S Strano
- Department of Chemical Engineering, Massachusetts Institute of Technology, 77 Massachusetts Ave., Cambridge, MA, 02139, USA
| |
Collapse
|
11
|
Melinte G, Selvolini G, Cristea C, Marrazza G. Aptasensors for lysozyme detection: Recent advances. Talanta 2021; 226:122169. [PMID: 33676711 DOI: 10.1016/j.talanta.2021.122169] [Citation(s) in RCA: 29] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2020] [Revised: 01/26/2021] [Accepted: 01/27/2021] [Indexed: 02/06/2023]
Abstract
Lysozyme is an enzyme existing in multiple organisms where it plays various vital roles. The most important role is its antibacterial activity in the human body; in fact, it is also called "the body's own antibiotic". Despite its proven utility, lysozyme can potentially trigger allergic reactions in sensitive individuals, even in trace amounts. Therefore, lysozyme determination in foods is becoming of paramount importance. Traditional detection methods are expensive, time-consuming and they cannot be applied for fast in-situ quantification. Electrochemical and optical sensors have attracted an increasing attention due to their versatility and ability to reduce the disadvantages of traditional methods. Using an aptamer as the bioreceptor, the sensor selectivity is amplified due to the specific recognition of the analyte. This review is presenting the progresses made in lysozyme determination by means of electrochemical and optical aptasensors in the last five years. A critical overview on the methodologies employed for aptamer immobilization and on the strategies for signal amplification of the assays will be described. Different optical and electrochemical aptasensors will be discussed and compared in terms of analytical performances, versatility and real samples applications.
Collapse
Affiliation(s)
- Gheorghe Melinte
- "Ugo Schiff" Chemistry Department, University of Florence, Via della Lastruccia 3, Sesto Fiorentino (FI), 50019, Italy; Analytical Chemistry Department, Faculty of Pharmacy, "Iuliu Hatieganu" University of Medicine and Pharmacy, Strada Louis Pasteur 4, Cluj-Napoca, 400349, Romania
| | - Giulia Selvolini
- "Ugo Schiff" Chemistry Department, University of Florence, Via della Lastruccia 3, Sesto Fiorentino (FI), 50019, Italy
| | - Cecilia Cristea
- Analytical Chemistry Department, Faculty of Pharmacy, "Iuliu Hatieganu" University of Medicine and Pharmacy, Strada Louis Pasteur 4, Cluj-Napoca, 400349, Romania.
| | - Giovanna Marrazza
- "Ugo Schiff" Chemistry Department, University of Florence, Via della Lastruccia 3, Sesto Fiorentino (FI), 50019, Italy; Istituto Nazionale Biostrutture e Biosistemi (INBB), Unit of Florence, Viale Delle Medaglie D'Oro 305, 00136 Roma, Italy.
| |
Collapse
|
12
|
Forouhi S, Ghafar-Zadeh E. Applications of CMOS Devices for the Diagnosis and Control of Infectious Diseases. MICROMACHINES 2020; 11:E1003. [PMID: 33202888 PMCID: PMC7698050 DOI: 10.3390/mi11111003] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/18/2020] [Revised: 11/03/2020] [Accepted: 11/06/2020] [Indexed: 12/25/2022]
Abstract
Emerging infectious diseases such as coronavirus disease of 2019 (COVID-19), Ebola, influenza A, severe acute respiratory syndrome (SARS) and Middle East respiratory syndrome (MERS) in recent years have threatened the health and security of the global community as one of the greatest factors of mortality in the world. Accurate and immediate diagnosis of infectious agents and symptoms is a key to control the outbreak of these diseases. Rapid advances in complementary metal-oxide-semiconductor (CMOS) technology offers great advantages like high accuracy, high throughput and rapid measurements in biomedical research and disease diagnosis. These features as well as low cost, low power and scalability of CMOS technology can pave the way for the development of powerful devices such as point-of-care (PoC) systems, lab-on-chip (LoC) platforms and symptom screening devices for accurate and timely diagnosis of infectious diseases. This paper is an overview of different CMOS-based devices such as optical, electrochemical, magnetic and mechanical sensors developed by researchers to mitigate the problems associated with these diseases.
Collapse
Affiliation(s)
- Saghi Forouhi
- Biologically Inspired Sensors and Actuators (BioSA), Department of Electrical Engineering and Computer Science (EECS), Lassonde School of Engineering, York University, Toronto, ON M3J 1P3, Canada;
| | | |
Collapse
|
13
|
Zhang R, Belwal T, Li L, Lin X, Xu Y, Luo Z. Nanomaterial‐based biosensors for sensing key foodborne pathogens: Advances from recent decades. Compr Rev Food Sci Food Saf 2020; 19:1465-1487. [DOI: 10.1111/1541-4337.12576] [Citation(s) in RCA: 37] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2019] [Revised: 04/11/2020] [Accepted: 04/21/2020] [Indexed: 12/13/2022]
Affiliation(s)
- Ruyuan Zhang
- College of Biosystems Engineering and Food Science, Key Laboratory of Agro‐Products Postharvest Handling of Ministry of Agriculture and Rural Affairs, Zhejiang Key Laboratory for Agri‐Food Processing, National‐Local Joint Engineering Laboratory of Intelligent Food Technology and EquipmentZhejiang University Hangzhou People's Republic of China
| | - Tarun Belwal
- College of Biosystems Engineering and Food Science, Key Laboratory of Agro‐Products Postharvest Handling of Ministry of Agriculture and Rural Affairs, Zhejiang Key Laboratory for Agri‐Food Processing, National‐Local Joint Engineering Laboratory of Intelligent Food Technology and EquipmentZhejiang University Hangzhou People's Republic of China
| | - Li Li
- College of Biosystems Engineering and Food Science, Key Laboratory of Agro‐Products Postharvest Handling of Ministry of Agriculture and Rural Affairs, Zhejiang Key Laboratory for Agri‐Food Processing, National‐Local Joint Engineering Laboratory of Intelligent Food Technology and EquipmentZhejiang University Hangzhou People's Republic of China
| | - Xingyu Lin
- College of Biosystems Engineering and Food Science, Key Laboratory of Agro‐Products Postharvest Handling of Ministry of Agriculture and Rural Affairs, Zhejiang Key Laboratory for Agri‐Food Processing, National‐Local Joint Engineering Laboratory of Intelligent Food Technology and EquipmentZhejiang University Hangzhou People's Republic of China
| | - Yanqun Xu
- College of Biosystems Engineering and Food Science, Key Laboratory of Agro‐Products Postharvest Handling of Ministry of Agriculture and Rural Affairs, Zhejiang Key Laboratory for Agri‐Food Processing, National‐Local Joint Engineering Laboratory of Intelligent Food Technology and EquipmentZhejiang University Hangzhou People's Republic of China
- Ningbo Research Institute, Zhejiang University Ningbo People's Republic of China
| | - Zisheng Luo
- College of Biosystems Engineering and Food Science, Key Laboratory of Agro‐Products Postharvest Handling of Ministry of Agriculture and Rural Affairs, Zhejiang Key Laboratory for Agri‐Food Processing, National‐Local Joint Engineering Laboratory of Intelligent Food Technology and EquipmentZhejiang University Hangzhou People's Republic of China
- Ningbo Research Institute, Zhejiang University Ningbo People's Republic of China
- Fuli Institute of Food Science Hangzhou People's Republic of China
| |
Collapse
|
14
|
Cassedy A, Mullins E, O'Kennedy R. Sowing seeds for the future: The need for on-site plant diagnostics. Biotechnol Adv 2020; 39:107358. [DOI: 10.1016/j.biotechadv.2019.02.014] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2018] [Revised: 01/28/2019] [Accepted: 02/21/2019] [Indexed: 01/09/2023]
|
15
|
Pei Y, Molley TG, Kilian KA. Enzyme Responsive Inverse Opal Hydrogels. Macromol Rapid Commun 2020; 41:e1900555. [PMID: 32003532 DOI: 10.1002/marc.201900555] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2019] [Revised: 12/19/2019] [Indexed: 12/13/2022]
Abstract
Structured color in nature is controlled by nano- and micro-structured interfaces giving rise to a photonic bandgap. This study presents a biomimetic optical material based on polymeric inverse opals that respond to enzyme activity. Polymer colloids provide a template in which acryloyl-functionalized poly(ethylene glycol) is integrated; dissolution of the colloids leads to a hydrogel inverse opal that can be lithographically patterned using transfer printing. Incorporating enzyme substrates within the voids provides a material that responds to the presence of proteases through a shift in the optical properties.
Collapse
Affiliation(s)
- Yi Pei
- School of Materials Science and Engineering, University of New South Wales, Sydney, 2052, Australia
| | - Thomas G Molley
- School of Materials Science and Engineering, University of New South Wales, Sydney, 2052, Australia
| | - Kristopher A Kilian
- School of Materials Science and Engineering, School of Chemistry, Australian Centre for Nanomedicine, University of New South Wales, Sydney, 2052, Australia
| |
Collapse
|
16
|
Eisner L, Wilhelm I, Flachenecker G, Hürttlen J, Schade W. Molecularly Imprinted Sol-Gel for TNT Detection with Optical Micro-Ring Resonator Sensor Chips. SENSORS 2019; 19:s19183909. [PMID: 31510108 PMCID: PMC6767136 DOI: 10.3390/s19183909] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/04/2019] [Revised: 08/30/2019] [Accepted: 09/08/2019] [Indexed: 01/04/2023]
Abstract
A sensor for trinitrotoluene (TNT) detection was developed by using a combination of optical micro-ring technology and a receptor coating based on molecularly imprinted sol-gel layers. Two techniques for deposition of receptor layers were compared: Airbrush technology and electrospray ionization. A concentration of less than 5 ppb for TNT in the gas-phase, using electrospray deposition of the receptor layer, was detected. The cross-sensitivities to organic substances and further nitro-based explosives were compared. As a result, the sensitivity to TNT is about one order of magnitude higher in comparison to the explosives 2,4-dinitrotoluene (DNT) or 1,3-dinitrobenzene (DNB) and about four orders of magnitude higher than the organic substances phenol, ethanol, and acetone. The signal response of the sensor is fast, and the compact sensor design enables the deposition of different receptor layers on multiple optical micro-rings on one chip, which allows a more precise analysis and reduction of side effects and false alarms.
Collapse
Affiliation(s)
- Ludmila Eisner
- Fraunhofer Heinrich-Hertz-Institute, Am Stollen 19H, 38640 Goslar, Germany.
| | - Isabel Wilhelm
- Fraunhofer Institute for Chemical Technology, Joseph-von- Fraunhofer Strasse 7, 76327 Pfinztal, Germany.
| | | | - Jürgen Hürttlen
- Fraunhofer Institute for Chemical Technology, Joseph-von- Fraunhofer Strasse 7, 76327 Pfinztal, Germany.
| | - Wolfgang Schade
- Fraunhofer Heinrich-Hertz-Institute, Am Stollen 19H, 38640 Goslar, Germany.
- Clausthal University of Technology, Am Stollen 19B, 38640 Goslar, Germany.
| |
Collapse
|
17
|
Mehrotra P, Chatterjee B, Sen S. EM-Wave Biosensors: A Review of RF, Microwave, mm-Wave and Optical Sensing. SENSORS (BASEL, SWITZERLAND) 2019; 19:E1013. [PMID: 30818865 PMCID: PMC6427747 DOI: 10.3390/s19051013] [Citation(s) in RCA: 78] [Impact Index Per Article: 15.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/23/2018] [Revised: 02/20/2019] [Accepted: 02/21/2019] [Indexed: 12/12/2022]
Abstract
This article presents a broad review on optical, radio-frequency (RF), microwave (MW), millimeter wave (mmW) and terahertz (THz) biosensors. Biomatter-wave interaction modalities are considered over a wide range of frequencies and applications such as detection of cancer biomarkers, biotin, neurotransmitters and heart rate are presented in detail. By treating biological tissue as a dielectric substance, having a unique dielectric signature, it can be characterized by frequency dependent parameters such as permittivity and conductivity. By observing the unique permittivity spectrum, cancerous cells can be distinguished from healthy ones or by measuring the changes in permittivity, concentration of medically relevant biomolecules such as glucose, neurotransmitters, vitamins and proteins, ailments and abnormalities can be detected. In case of optical biosensors, any change in permittivity is transduced to a change in optical properties such as photoluminescence, interference pattern, reflection intensity and reflection angle through techniques like quantum dots, interferometry, surface enhanced raman scattering or surface plasmon resonance. Conversely, in case of RF, MW, mmW and THz biosensors, capacitive sensing is most commonly employed where changes in permittivity are reflected as changes in capacitance, through components like interdigitated electrodes, resonators and microstrip structures. In this paper, interactions of EM waves with biomatter are considered, with an emphasis on a clear demarcation of various modalities, their underlying principles and applications.
Collapse
Affiliation(s)
| | | | - Shreyas Sen
- ECE, Purdue University, West Lafayette, IN 47906, USA.
| |
Collapse
|
18
|
Syedmoradi L, Esmaeili F, Norton ML. Towards DNA methylation detection using biosensors. Analyst 2018; 141:5922-5943. [PMID: 27704092 DOI: 10.1039/c6an01649a] [Citation(s) in RCA: 31] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
DNA methylation, a stable and heritable covalent modification which mostly occurs in the context of a CpG dinucleotide, has great potential as a biomarker to detect disease, provide prognoses and predict therapeutic responses. It can be detected in a quantitative manner by many different approaches both genome-wide and at specific gene loci, in various biological fluids such as urine, plasma, and serum, which can be obtained without invasive procedures. The current, classical methods are effective in studying DNA methylation patterns, however, for the most part; they have major drawbacks such as expensive instruments, complicated and time consuming protocols as well as relatively low sensitivity, and high false positive rates. To overcome these obstacles, great efforts have been made toward the development of reliable sensor devices to solve these limitations, providing sensitive, fast and cost-effective measurements. The use of biosensors for DNA methylation biomarkers has increased in recent years, because they are portable, simple, rapid, and inexpensive which offers a straightforward way to detect methylated biomarkers. In this review, we give an overview of the conventional techniques for the detection of DNA methylation and then will focus on recent advances in biosensor based methylation detection that eliminate bisulfite conversion and PCR amplification.
Collapse
Affiliation(s)
- Leila Syedmoradi
- Department of Medical Nanotechnology, School of Advanced Technologies in Medicine, Tehran University of Medical Sciences, Tehran, Iran
| | - Fariba Esmaeili
- Department of Medical Nanotechnology, School of Advanced Technologies in Medicine, Tehran University of Medical Sciences, Tehran, Iran
| | - Michael L Norton
- Department of Chemistry, Marshall University, One John Marshall Drive, Huntington, WV 25755, USA.
| |
Collapse
|
19
|
Lu M, Peng W, Liu Q, Liu Y, Li L, Liang Y, Masson JF. Dual channel multilayer-coated surface plasmon resonance sensor for dual refractive index range measurements. OPTICS EXPRESS 2017; 25:8563-8570. [PMID: 28437934 DOI: 10.1364/oe.25.008563] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
We present a novel multilayer-coated surface plasmon resonance sensor for dual refractive index range measurements based on a capillary structure. The sensing elements include an internally coated Ag layer and an externally coated bilayer of Au with an overlayer of thin indium tin oxide (ITO). The internal Ag layer was sensitive to higher refractive index (RI) medium while the external Au/ITO layer was sensitive to lower refractive index medium. We evaluated the sensor performance by measuring RI changes in two channels, RI sensitivities were -1951 nm/RIU and 2496 nm/RIU, respectively. This compact, low-cost large RI detection range SPR sensor offers the possibility for wider RI detection range and highly sensitive SPR studies in industry and chemical sensing.
Collapse
|
20
|
Exploring the Association of Surface Plasmon Resonance with Recombinant MHC:Ig Hybrid Protein as a Tool for Detecting T Lymphocytes in Mice Infected with Leishmania (Leishmania) amazonensis. BIOMED RESEARCH INTERNATIONAL 2017; 2017:9089748. [PMID: 28373990 PMCID: PMC5361054 DOI: 10.1155/2017/9089748] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/20/2016] [Revised: 01/10/2017] [Accepted: 02/02/2017] [Indexed: 11/18/2022]
Abstract
A surface plasmon resonance- (SPR-) based recognition method applying H-2 Ld:Ig/peptides complexes for ex vivo monitoring cellular immune responses during murine infection with Leishmania (Leishmania) amazonensis is described. Lymphocytes from lesion-draining popliteal lymph nodes were captured on a carboxylated sensor chip surface previously functionalized with H-2 Ld:Ig (DimerX) protein bound to synthetic peptides derived from the COOH-terminal region of cysteine proteinase B of L. (L.) amazonensis. In computational analysis, these peptides presented values of kinetic constants favorable to form complexes with H-2 Ld at neutral pH, with a Gibbs free energy ΔG° < 0. The assayed DimerX:peptide complexes presented the property of attaching to distinct T lymphocytes subsets, obtained from experimentally infected BALB/c mice, in each week of infection, thus indicating a temporal variation in specific T lymphocytes populations, each directed to a different COOH-terminal region-derived peptide. The experimental design proposed herein is an innovative approach for cellular immunology studies of a neglected disease, providing a useful tool for the analysis of specific T lymphocytes subsets.
Collapse
|
21
|
Suutari T, Silen T, S En Karaman D, Saari H, Desai D, Kerkelä E, Laitinen S, Hanzlikova M, Rosenholm JM, Yliperttula M, Viitala T. Real-Time Label-Free Monitoring of Nanoparticle Cell Uptake. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2016; 12:6289-6300. [PMID: 27690329 DOI: 10.1002/smll.201601815] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/30/2016] [Revised: 08/28/2016] [Indexed: 05/10/2023]
Abstract
The surface plasmon resonance technique in combination with whole cell sensing is used for the first time for real-time label-free monitoring of nanoparticle cell uptake. The uptake kinetics of several types of nanoparticles relevant to drug delivery applications into HeLa cells is determined. The cell uptake of the nanoparticles is confirmed by confocal microscopy. The cell uptake of silica nanoparticles and polyethylenimine-plasmid DNA polyplexes is studied as a function of temperature, and the uptake energies are determined by Arrhenius plots. The phase transition temperature of the HeLa cell membrane is detected when monitoring cell uptake of silica nanoparticles at different temperatures. The HeLa cell uptake of the mesoporous silica nanoparticles is energy-independent at temperatures slightly higher than the phase transition temperature of the HeLa cell membrane, while the uptake of polyethylenimine-DNA polyplexes is energy-dependent and linear as a function of temperature with an activation energy of Ea = 62 ± 7 kJ mol-1 = 15 ± 2 kcal mol-1 . The HeLa cell uptake of red blood cell derived extracellular vesicles is also studied as a function of the extracellular vesicle concentration. The results show a concentration dependent behavior reaching a saturation level of the extracellular vesicle uptake by HeLa cells.
Collapse
Affiliation(s)
- Teemu Suutari
- Centre for Drug Research at the Division of Pharmaceutical Biosciences, Faculty of Pharmacy, University of Helsinki, P.O. Box 56, 00014, Helsinki, Finland
| | - Tiina Silen
- Centre for Drug Research at the Division of Pharmaceutical Biosciences, Faculty of Pharmacy, University of Helsinki, P.O. Box 56, 00014, Helsinki, Finland
| | - Didem S En Karaman
- Pharmaceutical Sciences Laboratory, Faculty of Science and Engineering, Åbo Akademi University, BioCity 3rd floor, Artillerigatan 6A, 20520, Åbo, Finland
- Centre for Functional Materials, Laboratory for Physical Chemistry, Faculty of Science and Engineering, Åbo Akademi University, Porthansgatan 3-5, 20500, Åbo, Finland
| | - Heikki Saari
- Centre for Drug Research at the Division of Pharmaceutical Biosciences, Faculty of Pharmacy, University of Helsinki, P.O. Box 56, 00014, Helsinki, Finland
| | - Diti Desai
- Pharmaceutical Sciences Laboratory, Faculty of Science and Engineering, Åbo Akademi University, BioCity 3rd floor, Artillerigatan 6A, 20520, Åbo, Finland
| | - Erja Kerkelä
- Finnish Red Cross Blood Service, Kivihaantie 7, 00310, Helsinki, Finland
| | - Saara Laitinen
- Finnish Red Cross Blood Service, Kivihaantie 7, 00310, Helsinki, Finland
| | - Martina Hanzlikova
- Centre for Drug Research at the Division of Pharmaceutical Biosciences, Faculty of Pharmacy, University of Helsinki, P.O. Box 56, 00014, Helsinki, Finland
| | - Jessica M Rosenholm
- Pharmaceutical Sciences Laboratory, Faculty of Science and Engineering, Åbo Akademi University, BioCity 3rd floor, Artillerigatan 6A, 20520, Åbo, Finland
| | - Marjo Yliperttula
- Centre for Drug Research at the Division of Pharmaceutical Biosciences, Faculty of Pharmacy, University of Helsinki, P.O. Box 56, 00014, Helsinki, Finland
- Department of Pharmaceutical and Pharmacological Sciences, University of Padova, via F. Marzolo 5, Padova, Italy
| | - Tapani Viitala
- Centre for Drug Research at the Division of Pharmaceutical Biosciences, Faculty of Pharmacy, University of Helsinki, P.O. Box 56, 00014, Helsinki, Finland
| |
Collapse
|
22
|
Kutscher M, Rosenberger M, Schmauss B, Meinel L, Lorenz U, Ohlsen K, Hellmann R, Germershaus O. Surface functionalization allowing repetitive use of optical sensors for real-time detection of antibody-bacteria interaction. JOURNAL OF BIOPHOTONICS 2016; 9:730-737. [PMID: 26486822 DOI: 10.1002/jbio.201500178] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/12/2015] [Revised: 08/13/2015] [Accepted: 09/14/2015] [Indexed: 06/05/2023]
Abstract
In this study, sensor surface functionalization allowing the repetitive use of a sensing device was evaluated for antibody-based detection of living bacteria using an optical planar Bragg grating sensor. To achieve regenerable immobilization of bacteria specific antibodies, the heterobifunctional cross-linker N-succinimidyl 3-(2-pyridyldithio) propionate (SPDP) was linked to an aminosilanized sensor surface and subsequently reduced to expose sulfhydryl groups enabling the covalent conjugation of SPDP-activated antibodies via disulfide bonds. The immobilization of a capture antibody specific for Staphylococcus aureus on the sensor surface as well as specific binding of S. aureus could be monitored, highlighting the applicability of optical sensors for the specific detection of large biological structures. Reusability of bacteria saturated sensors was successfully demonstrated by cleaving the antibody along with bound bacteria through reduction of disulfide bonds and subsequent re-functionalization with activated antibody, resulting in comparable sensitivity towards S. aureus.
Collapse
Affiliation(s)
- Marika Kutscher
- Institute for Pharmacy and Food Chemistry, University of Wuerzburg, Am Hubland, 97074, Wuerzburg, Germany
| | - Manuel Rosenberger
- Applied Laser and Photonics Group, University of Applied Sciences Aschaffenburg, Wuerzburger Straße 45, 63743, Aschaffenburg, Germany
| | - Bernhard Schmauss
- Institute of Microwaves and Photonics, University of Erlangen-Nuernberg, Cauerstraße 9, 91058, Erlangen, Germany
| | - Lorenz Meinel
- Institute for Pharmacy and Food Chemistry, University of Wuerzburg, Am Hubland, 97074, Wuerzburg, Germany
| | - Udo Lorenz
- Department of General, Visceral, Vascular and Paediatric Surgery, University Clinic of Wuerzburg, Oberduerrbacher Str. 6, 97080, Wuerzburg, Germany
| | - Knut Ohlsen
- Institute for Molecular Infection Biology, University of Wuerzburg, Josef-Schneider-Str. 2, Bau D15, 97080, Wuerzburg, Germany
| | - Ralf Hellmann
- Applied Laser and Photonics Group, University of Applied Sciences Aschaffenburg, Wuerzburger Straße 45, 63743, Aschaffenburg, Germany.
| | - Oliver Germershaus
- Institute for Pharmacy and Food Chemistry, University of Wuerzburg, Am Hubland, 97074, Wuerzburg, Germany.
- Institute for Pharma Technology, School of Life Sciences, University of Applied Sciences and Arts Northwestern Switzerland, Gruendenstrasse 40, 4132, Muttenz, Switzerland.
| |
Collapse
|
23
|
Ribaut C, Voisin V, Malachovská V, Dubois V, Mégret P, Wattiez R, Caucheteur C. Small biomolecule immunosensing with plasmonic optical fiber grating sensor. Biosens Bioelectron 2016; 77:315-22. [DOI: 10.1016/j.bios.2015.09.019] [Citation(s) in RCA: 85] [Impact Index Per Article: 10.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2015] [Revised: 09/07/2015] [Accepted: 09/10/2015] [Indexed: 11/28/2022]
|
24
|
Nehra A, Pal Singh K. Current trends in nanomaterial embedded field effect transistor-based biosensor. Biosens Bioelectron 2015. [DOI: 10.1016/j.bios.2015.07.030] [Citation(s) in RCA: 79] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
|
25
|
Romero-Arcos M, Garnica-Romo MG, Martinez-Flores HE, Vázquez-Marrufo G, Ramírez-Bon R, González-Hernández J, Barbosa-Cánovas GV. Enzyme Immobilization by Amperometric Biosensors with TiO2 Nanoparticles Used to Detect Phenol Compounds. FOOD ENGINEERING REVIEWS 2015. [DOI: 10.1007/s12393-015-9129-8] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
26
|
Recent trends in rapid environmental monitoring of pathogens and toxicants: potential of nanoparticle-based biosensor and applications. ScientificWorldJournal 2015; 2015:510982. [PMID: 25884032 PMCID: PMC4390168 DOI: 10.1155/2015/510982] [Citation(s) in RCA: 51] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2014] [Revised: 11/07/2014] [Accepted: 11/07/2014] [Indexed: 11/23/2022] Open
Abstract
Of global concern, environmental pollution adversely affects human health and socioeconomic development. The presence of environmental contaminants, especially bacterial, viral, and parasitic pathogens and their toxins as well as chemical substances, poses serious public health concerns. Nanoparticle-based biosensors are considered as potential tools for rapid, specific, and highly sensitive detection of the analyte of interest (both biotic and abiotic contaminants). In particular, there are several limitations of conventional detection methods for water-borne pathogens due to low concentrations and interference with various enzymatic inhibitors in the environmental samples. The increase of cells to detection levels requires long incubation time. This review describes current state of biosensor nanotechnology, the advantage over conventional detection methods, and the challenges due to testing of environmental samples. The major approach is to use nanoparticles as signal reporter to increase output rather than spending time to increase cell concentrations. Trends in future development of novel detection devices and their advantages over other environmental monitoring methodologies are also discussed.
Collapse
|
27
|
Monošík R, Stred'anský M, Šturdík E. Application of electrochemical biosensors in clinical diagnosis. J Clin Lab Anal 2014; 26:22-34. [PMID: 24833531 DOI: 10.1002/jcla.20500] [Citation(s) in RCA: 61] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2011] [Accepted: 09/08/2011] [Indexed: 11/08/2022] Open
Abstract
Analyses in the clinical area need quick and reliable analytical methods and devices. For this purpose, biosensors can be a suitable option, whereas they are constructed to be simple for use, specific for the target analyte, capable of continuous monitoring and giving quick results, potentially low-costing and portable. In this article, we describe electrochemical biosensors developed for clinical diagnosis, namely for glucose, lactate, cholesterol, urea, creatinine, DNA, antigens, antibodies, and cancer markers assays. Chosen biosensors showed desirable sensitivity, selectivity, and potential for application on real samples. They are often designed to avoid interference with undesired components present in the monitored systems.
Collapse
Affiliation(s)
- Rastislav Monošík
- Institute of Biochemistry, Nutrition and Health Protection, Faculty of Chemical and Food Technology, Slovak University of Technology, Bratislava, Slovak Republic. ,
| | | | | |
Collapse
|
28
|
Souza-Silva F, Pereira BAS, Finkelstein LC, Zucolotto V, Caffarena ER, Alves CR. Dynamic identification of H2 epitopes from Leishmania (Leishmania) amazonensis cysteine proteinase B with potential immune activity during murine infection. J Mol Recognit 2014; 27:98-105. [PMID: 24436127 DOI: 10.1002/jmr.2334] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2013] [Revised: 10/09/2013] [Accepted: 10/12/2013] [Indexed: 11/11/2022]
Abstract
Peptides from the COOH-terminal extension of cysteine proteinase B from Leishmania (Leishmania) amazonensis (cyspep) can modulate immune responses in vertebrate hosts. With this hypothesis as base, we used the online analysis tool SYFPEITHI to predict seven epitopes from this region with potential to bind H2 proteins. We performed proliferation tests and quantified reactive T lymphocytes applying a cytometry analysis, using samples from draining lymph node of lesions from L. (L.) amazonensis-infected mice. To define reactivity of T cells, we used complexes of DimerX (H2 D(b):Ig and H2 L(d):Ig) and the putative epitopes. Additionally, we applied surface plasmon resonance to verify real time interactions between the putative epitopes and DimerX proteins. Five peptides induced blastogenesis in BALB/c cells, while only two presented the same property in C57BL/6 mouse cells. In addition, our data indicate the existence of CD8+ T lymphocyte populations able to recognize each tested peptide in both murine strains. We observed an overlapping of results between the peptides that induced lymphocyte proliferation and those capable of binding to the DimerX in the surface plasmon resonance assays thus indicating that using these recombinant proteins in biosensing analyses is a promising tool to study real time molecular interactions in the context of major histocompatibility complex epitopes. The data gathered in this study reinforce the hypothesis that cyspep-derived peptides are important factors in the murine host infection by L. (L.) amazonensis.
Collapse
Affiliation(s)
- Franklin Souza-Silva
- Laboratório de Biologia Molecular e Doenças Endêmicas, IOC-Fundação Oswaldo Cruz, Rio de Janeiro, CEP, 21040-360, Brazil
| | | | | | | | | | | |
Collapse
|
29
|
Ziółczyk P, Kur-Kowalska K, Przybyt M, Miller E. Quantum dots as a possible oxygen sensor. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2014; 126:28-35. [PMID: 24568848 DOI: 10.1016/j.saa.2014.01.112] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/09/2013] [Revised: 01/15/2014] [Accepted: 01/22/2014] [Indexed: 06/03/2023]
Abstract
Results of studies on optical properties of low toxicity quantum dots (QDs) obtained from copper doped zinc sulfate are discussed in the paper. The effect of copper admixture concentration and solution pH on the fluorescence emission intensity of QDs was investigated. Quenching of QDs fluorescence by oxygen was reported and removal of the oxygen from the environment by two methods was described. In the chemical method oxygen was eliminated by adding sodium sulfite, in the other method oxygen was removed from the solution using nitrogen gas. For elimination of oxygen by purging the solution with nitrogen the increase of fluorescence intensity with decreasing oxygen concentration obeyed Stern-Volmer equation indicating quenching. For the chemical method Stern-Volmer equation was not fulfilled. The fluorescence decays lifetimes were determined and the increase of mean lifetimes at the absence of oxygen support hypothesis that QDs fluorescence is quenched by oxygen.
Collapse
Affiliation(s)
- Paulina Ziółczyk
- Institute of General Food Chemistry, Lodz University of Technology, Stefanowskiego 4/10, 90-924 Łódź, Poland
| | - Katarzyna Kur-Kowalska
- Institute of General Food Chemistry, Lodz University of Technology, Stefanowskiego 4/10, 90-924 Łódź, Poland
| | - Małgorzata Przybyt
- Institute of General Food Chemistry, Lodz University of Technology, Stefanowskiego 4/10, 90-924 Łódź, Poland
| | - Ewa Miller
- Institute of General Food Chemistry, Lodz University of Technology, Stefanowskiego 4/10, 90-924 Łódź, Poland.
| |
Collapse
|
30
|
Tahmasebpour M, Bahrami M, Asgari A. Design study of nanograting-based surface plasmon resonance biosensor in the near-infrared wavelength. APPLIED OPTICS 2014; 53:1449-58. [PMID: 24663375 DOI: 10.1364/ao.53.001449] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/31/2013] [Accepted: 01/27/2014] [Indexed: 05/26/2023]
Abstract
A key issue with surface plasmon resonance (SPR) biosensors, which are the focus of many researchers, is improving their sensitivity to detect lower amounts of analyte in a solution. Most SPR developments have focused on the grating-based sensitivity-enhancement approach. In addition to sensitivity, a substantial enhancement of other sensor characteristics such as resolution and signal-to-noise ratio (SNR) is desired for designing a practical sensor. So, in this paper, the characteristics of surface plasmon polaritons sustained by 1D subwavelength metallic gratings on a thin metal slab (under the Krestchmann configuration) have been investigated numerically for the analyte-ligand interactions detection. Effects of different structural parameters, such as grating period, grating depth, metal film thickness, and fill factor have been evaluated on the sensor sensitivity as well as resolution and SNR. Numerical results indicate that the sensor working in the near-infrared wavelength has a better performance than that in the visible one. The result of numerical investigation has been used to design an optimized sensor with the best figure of merit.
Collapse
|
31
|
Polley N, Singh S, Giri A, Pal SK. Evanescent field: a potential light-tool for theranostics application. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2014; 85:033108. [PMID: 24689565 DOI: 10.1063/1.4868589] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
A noninvasive or minimally invasive optical approach for theranostics, which would reinforce diagnosis, treatment, and preferably guidance simultaneously, is considered to be major challenge in biomedical instrument design. In the present work, we have developed an evanescent field-based fiber optic strategy for the potential theranostics application in hyperbilirubinemia, an increased concentration of bilirubin in the blood and is a potential cause of permanent brain damage or even death in newborn babies. Potential problem of bilirubin deposition on the hydroxylated fiber surface at physiological pH (7.4), that masks the sensing efficacy and extraction of information of the pigment level, has also been addressed. Removal of bilirubin in a blood-phantom (hemoglobin and human serum albumin) solution from an enhanced level of 77 μM/l (human jaundice >50 μM/l) to ~30 μM/l (normal level ~25 μM/l in human) using our strategy has been successfully demonstrated. In a model experiment using chromatography paper as a mimic of biological membrane, we have shown efficient degradation of the bilirubin under continuous monitoring for guidance of immediate/future course of action.
Collapse
Affiliation(s)
- Nabarun Polley
- Department of Chemical, Biological and Macromolecular Sciences, S. N. Bose National Centre for Basic Sciences, Block JD, Sector III, Salt Lake, Kolkata 700 098, India
| | - Soumendra Singh
- Department of Chemical, Biological and Macromolecular Sciences, S. N. Bose National Centre for Basic Sciences, Block JD, Sector III, Salt Lake, Kolkata 700 098, India
| | - Anupam Giri
- Department of Chemical, Biological and Macromolecular Sciences, S. N. Bose National Centre for Basic Sciences, Block JD, Sector III, Salt Lake, Kolkata 700 098, India
| | - Samir Kumar Pal
- Department of Chemical, Biological and Macromolecular Sciences, S. N. Bose National Centre for Basic Sciences, Block JD, Sector III, Salt Lake, Kolkata 700 098, India
| |
Collapse
|
32
|
Habib-Ullah S, Fei D, Ge Y. Nanotechnology in Advanced Medical Devices. Nanomedicine (Lond) 2014. [DOI: 10.1007/978-1-4614-2140-5_8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022] Open
|
33
|
Identification of the molecular mechanisms in cellular processes that elicit a surface plasmon resonance (SPR) response using simultaneous surface plasmon-enhanced fluorescence (SPEF) microscopy. Biosens Bioelectron 2013; 50:125-31. [DOI: 10.1016/j.bios.2013.06.018] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2013] [Revised: 05/29/2013] [Accepted: 06/07/2013] [Indexed: 11/24/2022]
|
34
|
Zhang D, Zhang F, Zhang Q, Lu Y, Liu Q, Wang P. Umami evaluation in taste epithelium on microelectrode array by extracellular electrophysiological recording. Biochem Biophys Res Commun 2013; 438:334-9. [PMID: 23892037 DOI: 10.1016/j.bbrc.2013.07.072] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2013] [Accepted: 07/18/2013] [Indexed: 11/18/2022]
Abstract
Umami is one of the basic tastes along with sweet, bitter, sour and salty. It is often elicited by amino acids and can provide a palatable flavor for food. With taste epithelium as the sensing element, microelectrodes can be used to evaluate umami taste by biological responses of the tissue. The electrophysiological activities to umami stimuli are measured with a 60-channel microelectrode array (MEA). Local field potential (LFP) recorded by a MEA system showed different temporal characteristics respectively with l-glutamic acid (l-Glu), l-aspartic acid (l-Asp), l-monosodium glutamate (l-MSG) and l-monosodium aspartate (l-MSA), while remarkable differences were observed between amino acids and their sodium salts. We also found that a dose-dependent behavior in the increasing concentrations of umami stimulations and a synergistic enhancement between amino acids and purine nucleotides can be detected. The investigation of this evaluation for umami represents a promising approach for distinguishing and evaluating umami tastants.
Collapse
Affiliation(s)
- Diming Zhang
- Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Education Ministry, Department of Biomedical Engineering, Zhejiang University, Hangzhou 310027, PR China
| | | | | | | | | | | |
Collapse
|
35
|
Kanwal A, Lakshmanan S, Bendiganavale A, Bot CT, Patlolla A, Raj R, Prodan C, Iqbal Z, Thomas GA, Farrow RC. Scalable nano-bioprobes with sub-cellular resolution for cell detection. Biosens Bioelectron 2013; 45:267-73. [PMID: 23500374 DOI: 10.1016/j.bios.2013.01.066] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2012] [Revised: 01/20/2013] [Accepted: 01/27/2013] [Indexed: 10/27/2022]
Abstract
Here we present a carbon nanotube based device to noninvasively and quickly detect mobile single cells with the potential to maintain a high degree of spatial resolution. The device utilizes standard complementary metal oxide semiconductor (CMOS) technologies for fabrication, allowing it to be easily scalable (down to a few nanometers). Nanotubes are deposited using electrophoresis after fabrication in order to maintain CMOS compatibility. The devices are spaced by 6 μm which is the same size or smaller than a single cell. To demonstrate its capability to detect cells, we performed impedance spectroscopy on mobile human embryonic kidney (HEK) cells, neurons cells from mice, and yeast cells (S. pombe). Measurements were performed with and without cells and with and without nanotubes. Nanotubes were found to be crucial to successfully detect the presence of cells. The devices are also able to distinguish between cells with different characteristics.
Collapse
Affiliation(s)
- Alokik Kanwal
- New Jersey Institute of Technology, Department of Physics, Newark, NJ 07102, USA.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
36
|
Yang H, Gijs MAM. Microtextured Substrates and Microparticles Used as in Situ Lenses for On-Chip Immunofluorescence Amplification. Anal Chem 2013; 85:2064-71. [DOI: 10.1021/ac303471x] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Hui Yang
- Laboratory of Microsystems, Ecole Polytechnique Fédérale de Lausanne, CH-1015 Lausanne,
Switzerland
| | - Martin A. M. Gijs
- Laboratory of Microsystems, Ecole Polytechnique Fédérale de Lausanne, CH-1015 Lausanne,
Switzerland
| |
Collapse
|
37
|
|
38
|
Alvarez M, Fariña D, Escuela AM, Sendra JR, Lechuga LM. Development of a surface plasmon resonance and nanomechanical biosensing hybrid platform for multiparametric reading. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2013; 84:015008. [PMID: 23387688 DOI: 10.1063/1.4789430] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
We have developed a hybrid platform that combines two well-known biosensing technologies based on quite different transducer principles: surface plasmon resonance and nanomechanical sensing. The new system allows the simultaneous and real-time detection of two independent parameters, refractive index change (Δn), and surface stress change (Δσ) when a biomolecular interaction takes place. Both parameters have a direct relation with the mass coverage of the sensor surface. The core of the platform is a common fluid cell, where the solution arrives to both sensor areas at the same time and under the same conditions (temperature, velocity, diffusion, etc.).The main objective of this integration is to achieve a better understanding of the physical behaviour of the transducers during sensing, increasing the information obtained in real time in one single experiment. The potential of the hybrid platform is demonstrated by the detection of DNA hybridization.
Collapse
Affiliation(s)
- Mar Alvarez
- Nanobiosensors and Bioanalytical Applications Group, Research Center on Nanoscience and Nanotechnology CIN2(CSIC) and CIBER-BBN, 08193 Bellaterra, Barcelona, Spain.
| | | | | | | | | |
Collapse
|
39
|
Rodríguez P, Rojas H, Medina M, Arrivillaga J, Francisco Y, Dager F, Piscitelli V, Caetano M, Fernández A, Castillo J. Study of Functionalized Gold Nanoparticles with Anti-gp63 IgG Antibody for the Detection of Glycoprotein gp63 in Membrane Surface of <i>Leishmania</i> Genus Parasites. ACTA ACUST UNITED AC 2013. [DOI: 10.4236/ajac.2013.47a014] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
40
|
Shinde SB, Fernandes CB, Patravale VB. Recent trends in in-vitro nanodiagnostics for detection of pathogens. J Control Release 2012; 159:164-80. [DOI: 10.1016/j.jconrel.2011.11.033] [Citation(s) in RCA: 62] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2011] [Accepted: 11/23/2011] [Indexed: 11/17/2022]
|
41
|
Abstract
Biosensors - classification, characterization and new trendsBiosensors represent promising analytical tools applicable in areas such as clinical diagnosis, food industry, environment monitoring and in other fields, where rapid and reliable analyses are needed. Some biosensors were successfully implemented in the commercial sphere, but majority needs to be improved in order to overcome some imperfections. This review covers the basic types, principles, constructions and use of biosensors as well as new trends used for their fabrication.
Collapse
|
42
|
Mazhorova A, Markov A, Ng A, Chinnappan R, Skorobogata O, Zourob M, Skorobogatiy M. Label-free bacteria detection using evanescent mode of a suspended core terahertz fiber. OPTICS EXPRESS 2012; 20:5344-55. [PMID: 22418342 DOI: 10.1364/oe.20.005344] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
Abstract
We propose for the first time an E. coli bacteria sensor based on the evanescent field of the fundamental mode of a suspended-core terahertz fiber. The sensor is capable of E. coli detection at concentrations in the range of 10(4)-10(9) cfu/ml. The polyethylene fiber features a 150 µm core suspended by three deeply sub-wavelength bridges in the center of a 5.1 mm-diameter cladding tube. The fiber core is biofunctionalized with T4 bacteriophages which bind and eventually destroy (lyse) their bacterial target. Using environmental SEM we demonstrate that E. coli is first captured by the phages on the fiber surface. After 25 minutes, most of the bacteria is infected by phages and then destroyed with ~1 μm-size fragments remaining bound to the fiber surface. The bacteria-binding and subsequent lysis unambiguously correlate with a strong increase of the fiber absorption. This signal allows the detection and quantification of bacteria concentration. Presented bacteria detection method is label-free and it does not rely on the presence of any bacterial "fingerprint" features in the THz spectrum.
Collapse
Affiliation(s)
- Anna Mazhorova
- École Polytechnique de Montréal, Génie Physique, Québec, Canada
| | | | | | | | | | | | | |
Collapse
|
43
|
Rich RL, Myszka DG. Survey of the 2009 commercial optical biosensor literature. J Mol Recognit 2012; 24:892-914. [PMID: 22038797 DOI: 10.1002/jmr.1138] [Citation(s) in RCA: 83] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
We took a different approach to reviewing the commercial biosensor literature this year by inviting 22 biosensor users to serve as a review committee. They set the criteria for what to expect in a publication and ultimately decided to use a pass/fail system for selecting which papers to include in this year's reference list. Of the 1514 publications in 2009 that reported using commercially available optical biosensor technology, only 20% passed their cutoff. The most common criticism the reviewers had with the literature was that "the biosensor experiments could have been done better." They selected 10 papers to highlight good experimental technique, data presentation, and unique applications of the technology. This communal review process was educational for everyone involved and one we will not soon forget.
Collapse
Affiliation(s)
- Rebecca L Rich
- Center for Biomolecular Interaction Analysis, University of Utah, Salt Lake City, UT, USA
| | | |
Collapse
|
44
|
Eltzov E, Cosnier S, Marks RS. Biosensors based on combined optical and electrochemical transduction for molecular diagnostics. Expert Rev Mol Diagn 2012; 11:533-46. [PMID: 21707461 DOI: 10.1586/erm.11.38] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Abstract
Electrochemical and optical biosensors exist to monitor different fluids containing analytes of interest. Until today, these have been developed separately. Owing to the creation of new transducer configurations such as indium tin-coated glass fiber optics, these methods can now be used separately, in parallel and it is hoped that one day they will be able to be used simultaneously; thus, using the same probe to measure a single analyte using two different methods (electrochemical and optical) or two different analytes with either of the aforementioned methods sitting on the same probe. This article will highlight the importance, as well as the usefulness, of combining measurement methodologies in improving sensor response and sensitivity.
Collapse
Affiliation(s)
- Evgeni Eltzov
- Unit of Environmental Engineering, Ben-Gurion University of the Negev, Beer-Sheva, Israel
| | | | | |
Collapse
|
45
|
|
46
|
Leishmania (Viannia) braziliensis: insights on subcellular distribution and biochemical properties of heparin-binding proteins. Parasitology 2011; 139:200-7. [PMID: 22053722 DOI: 10.1017/s0031182011001910] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
Leishmaniasis is a vector-borne disease and an important public health issue. Glycosaminoglycan ligands in Leishmania parasites are potential targets for new strategies to control this disease. We report the subcellular distribution of heparin-binding proteins (HBPs) in Leishmania (Viannia) braziliensis and specific biochemical characteristics of L. (V.) braziliensis HBPs. Promastigotes were fractionated, and flagella and membrane samples were applied to HiTrap Heparin affinity chromatography columns. Heparin-bound fractions from flagella and membrane samples were designated HBP Ff and HBP Mf, respectively. Fraction HBP Ff presented a higher concentration of HBPs relative to HBP Mf, and SDS-PAGE analyses showed 2 major protein bands in both fractions (65 and 55 kDa). The 65 kDa band showed gelatinolytic activity and was sensitive to inhibition by 1,10-phenanthroline. The localization of HBPs on the promastigote surfaces was confirmed using surface plasmon resonance (SPR) biosensor analysis by binding the parasites to a heparin-coated sensor chip; that was inhibited in a dose-dependent manner by pre-incubating the parasites with variable concentrations of heparin, thus indicating distinct heparin-binding capacities for the two fractions. In conclusion, protein fractions isolated from either the flagella or membranes of L. (V.) braziliensis promastigotes have characteristics of metallo-proteinases and are able to bind to glycosaminoglycans.
Collapse
|
47
|
Saberian M, Hamzeiy H, Aghanejad A, Asgari D. Aptamer-based Nanosensors: Juglone as an Attached-Redox Molecule for Detection of Small Molecules. BIOIMPACTS : BI 2011; 1:31-6. [PMID: 23678405 PMCID: PMC3648941 DOI: 10.5681/bi.2011.005] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Received: 02/11/2011] [Revised: 02/22/2011] [Accepted: 03/09/2011] [Indexed: 11/17/2022]
Abstract
INTRODUCTION Among several biosensing approaches, electrochemical-based procedures have been described as one of the most common and useful methods for sensing because of their simplicity, sensitivity, accuracy, and low cost. The electroactive species, which called redox, play a main role in the electrochemical-based approaches. Among several redox molecules used for electrochemical experiments, ferrocene is one of the commonly used redox molecules. However, instability of ferrocenium ion in the chloride containing solutions appeared to be weakness of this redox molecule limiting its utilization. METHODS In the current study, Juglone was attached (using EDC/NHS coupling method) to the 3'-amino-modified terminus of the immobilized specific aptamer of codeine, which was successfully used in a cyclic electrochemical voltammetry procedure. RESULTS The cyclic voltammogram peak of aptamer-attached Juglone was observed in the potential range of +0.4 to +0.9 V and the fabricated aptamer-based sensor was used for detection of different concentrations of codeine in the phosphate buffer 0.1 M solution containing 2 M NaCl. CONCLUSION Based on these findings, it can be suggested that the new aptamer-attached Juglone could be considered as an effective alternative redox molecule in particular with oligonucleotide-based sensing systems.
Collapse
Affiliation(s)
- Mehdi Saberian
- Research Center for Pharmaceutical Nanotechnology
- Pharmacology and Toxicology Department, Faculty of Pharmacy, Tabriz
| | - Hossein Hamzeiy
- Research Center for Pharmaceutical Nanotechnology
- Pharmacology and Toxicology Department, Faculty of Pharmacy, Tabriz
| | | | | |
Collapse
|
48
|
Soria S, Berneschi S, Brenci M, Cosi F, Conti GN, Pelli S, Righini GC. Optical microspherical resonators for biomedical sensing. SENSORS (BASEL, SWITZERLAND) 2011; 11:785-805. [PMID: 22346603 PMCID: PMC3274111 DOI: 10.3390/s110100785] [Citation(s) in RCA: 87] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/08/2010] [Revised: 12/28/2010] [Accepted: 01/06/2011] [Indexed: 12/21/2022]
Abstract
Optical resonators play an ubiquitous role in modern optics. A particular class of optical resonators is constituted by spherical dielectric structures, where optical rays are total internal reflected. Due to minimal reflection losses and to potentially very low material absorption, these guided modes, known as whispering gallery modes, can confer the resonator an exceptionally high quality factor Q, leading to high energy density, narrow resonant-wavelength lines and a lengthy cavity ringdown. These attractive characteristics make these miniaturized optical resonators especially suited as laser cavities and resonant filters, but also as very sensitive sensors. First, a brief analysis is presented of the characteristics of microspherical resonators, of their fabrication methods, and of the light coupling techniques. Then, we attempt to overview some of the recent advances in the development of microspherical biosensors, underlining a number of important applications in the biomedical field.
Collapse
Affiliation(s)
- Silvia Soria
- MDF Lab, Istituto di Fisica Applicata Nello Carrara (IFAC CNR), Via Madonna del Piano 10, 50019 Sesto Fiorentino, Firenze, Italy; E-Mails: (S.B.); (M.B.); (F.C.); (G.N.C.); (S.P.); (G.C.R.)
| | - Simone Berneschi
- MDF Lab, Istituto di Fisica Applicata Nello Carrara (IFAC CNR), Via Madonna del Piano 10, 50019 Sesto Fiorentino, Firenze, Italy; E-Mails: (S.B.); (M.B.); (F.C.); (G.N.C.); (S.P.); (G.C.R.)
- Centro Studi e Ricerche e Museo Storico della Fisica Enrico Fermi, Piazza del Viminale 1, 00184 Roma, Italy
| | - Massimo Brenci
- MDF Lab, Istituto di Fisica Applicata Nello Carrara (IFAC CNR), Via Madonna del Piano 10, 50019 Sesto Fiorentino, Firenze, Italy; E-Mails: (S.B.); (M.B.); (F.C.); (G.N.C.); (S.P.); (G.C.R.)
| | - Franco Cosi
- MDF Lab, Istituto di Fisica Applicata Nello Carrara (IFAC CNR), Via Madonna del Piano 10, 50019 Sesto Fiorentino, Firenze, Italy; E-Mails: (S.B.); (M.B.); (F.C.); (G.N.C.); (S.P.); (G.C.R.)
| | - Gualtiero Nunzi Conti
- MDF Lab, Istituto di Fisica Applicata Nello Carrara (IFAC CNR), Via Madonna del Piano 10, 50019 Sesto Fiorentino, Firenze, Italy; E-Mails: (S.B.); (M.B.); (F.C.); (G.N.C.); (S.P.); (G.C.R.)
| | - Stefano Pelli
- MDF Lab, Istituto di Fisica Applicata Nello Carrara (IFAC CNR), Via Madonna del Piano 10, 50019 Sesto Fiorentino, Firenze, Italy; E-Mails: (S.B.); (M.B.); (F.C.); (G.N.C.); (S.P.); (G.C.R.)
| | - Giancarlo C. Righini
- MDF Lab, Istituto di Fisica Applicata Nello Carrara (IFAC CNR), Via Madonna del Piano 10, 50019 Sesto Fiorentino, Firenze, Italy; E-Mails: (S.B.); (M.B.); (F.C.); (G.N.C.); (S.P.); (G.C.R.)
| |
Collapse
|
49
|
Abstract
Transfusion safety relating to blood-transmissible agents is a major public health concern, particularly when faced with the continuing emergence of new infectious agents. These include new viruses appearing alongside other known reemerging viruses (West Nile virus, Chikungunya) as well as new strains of bacteria and parasites (Plasmodium falciparum, Trypanosoma cruzi) and finally pathologic prion protein (variant Creutzfeldt-Jakob disease). Genomic mutations of known viruses (hepatitis B virus, hepatitis C virus, human immunodeficiency virus) can also be at the origin of variants susceptible to escaping detection by diagnostic tests. New technologies that would allow the simultaneous detection of several blood-transmissible agents are now needed for the development and improvement of screening strategies. DNA microarrays have been developed for use in immunohematology laboratories for blood group genotyping. Their application in the detection of infectious agents, however, has been hindered by additional technological hurdles. For instance, the variability among and within genomes of interest complicate target amplification and multiplex analysis. Advances in biosensor technologies based on alternative detection strategies have offered new perspectives on pathogen detection; however, whether they are adaptable to diagnostic applications testing biologic fluids is under debate. Elsewhere, current nanotechnologies now offer new tools to improve the sample preparation, target capture, and detection steps. Second-generation devices combining micro- and nanotechnologies have brought us one step closer to the potential development of innovative and multiplexed approaches applicable to the screening of blood for transmissible agents.
Collapse
Affiliation(s)
- Chantal Fournier-Wirth
- Laboratoire de R&D-Agents Transmissibles par Transfusion (R&D-ATT), Etablissement Français du Sang Pyrénées-Méditerranée, Montpellier, France.
| | | | | |
Collapse
|
50
|
Ansari AA, Alhoshan M, Alsalhi MS, Aldwayyan AS. Prospects of nanotechnology in clinical immunodiagnostics. SENSORS 2010; 10:6535-81. [PMID: 22163566 PMCID: PMC3231125 DOI: 10.3390/s100706535] [Citation(s) in RCA: 43] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/30/2010] [Revised: 06/12/2010] [Accepted: 06/30/2010] [Indexed: 01/08/2023]
Abstract
Nanostructured materials are promising compounds that offer new opportunities as sensing platforms for the detection of biomolecules. Having micrometer-scale length and nanometer-scale diameters, nanomaterials can be manipulated with current nanofabrication methods, as well as self-assembly techniques, to fabricate nanoscale bio-sensing devices. Nanostructured materials possess extraordinary physical, mechanical, electrical, thermal and multifunctional properties. Such unique properties advocate their use as biomimetic membranes to immobilize and modify biomolecules on the surface of nanoparticles. Alignment, uniform dispersion, selective growth and diameter control are general parameters which play critical roles in the successful integration of nanostructures for the fabrication of bioelectronic sensing devices. In this review, we focus on different types and aspects of nanomaterials, including their synthesis, properties, conjugation with biomolecules and their application in the construction of immunosensing devices. Some key results from each cited article are summarized by relating the concept and mechanism behind each sensor, experimental conditions and the behavior of the sensor under different conditions, etc. The variety of nanomaterial-based bioelectronic devices exhibiting novel functions proves the unique properties of nanomaterials in such sensing devices, which will surely continue to expand in the future. Such nanomaterial based devices are expected to have a major impact in clinical immunodiagnostics, environmental monitoring, security surveillance and for ensuring food safety.
Collapse
Affiliation(s)
- Anees A. Ansari
- King Abdullah Institute for Nanotechnology, King Saud University, Riyadh-11451, P.O. Box-2455, Saudi Arabia; E-Mails: (M.S.A.); (A.S.A.)
- Author to whom correspondence should be addressed; E-Mail: ; Tel.: +966-1-4676838; Fax: +966-1-0545797441
| | - Mansour Alhoshan
- King Abdullah Institute for Nanotechnology, King Saud University, Riyadh-11451, P.O. Box-2455, Saudi Arabia; E-Mails: (M.S.A.); (A.S.A.)
- Department of Chemical Engineering, College of Engineering, King Saud University, Riyadh-11451, P.O. Box-2454, Saudi Arabia, E-Mail:
| | - Mohamad S. Alsalhi
- King Abdullah Institute for Nanotechnology, King Saud University, Riyadh-11451, P.O. Box-2455, Saudi Arabia; E-Mails: (M.S.A.); (A.S.A.)
- Department of Physics and Astronomy, College of Science, King Saud University, Riyadh-11451, P.O. Box-2455, Saudi Arabia
| | - Abdullah S. Aldwayyan
- King Abdullah Institute for Nanotechnology, King Saud University, Riyadh-11451, P.O. Box-2455, Saudi Arabia; E-Mails: (M.S.A.); (A.S.A.)
- Department of Physics and Astronomy, College of Science, King Saud University, Riyadh-11451, P.O. Box-2455, Saudi Arabia
| |
Collapse
|