1
|
Yoo H, Mahato M, Oh W, Ha J, Han H, Ahn CW, Oh IK. Exploring role of microbatteries in enhancing sustainability and functionality of implantable biosensors and bioelectronics. Biosens Bioelectron 2024; 260:116419. [PMID: 38830292 DOI: 10.1016/j.bios.2024.116419] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2024] [Revised: 04/13/2024] [Accepted: 05/20/2024] [Indexed: 06/05/2024]
Abstract
Microbatteries are emerging as a sustainable, miniaturized power source, crucial for implantable biomedical devices. Their significance lies in offering high energy density, longevity, and rechargeability, facilitating uninterrupted health monitoring and treatment within the body. The review delves into the development of microbatteries, emphasizing their miniaturization and biocompatibility, crucial for long-term, safe in-vivo use. It examines cutting-edge manufacturing techniques like physical and chemical vapor deposition, and atomic layer deposition, essential for the precision manufacture of the microbatteries. The paper contrasts primary and secondary batteries, highlighting the advantages of zinc-ion and magnesium-ion batteries for enhanced stability and reduced reactivity. It also explores biodegradable batteries, potentially obviating the need for surgical extraction post-use. The integration of microbatteries into diagnostic and therapeutic devices is also discussed, illustrating how they enhance the efficacy and sustainability of implantable biosensors and bioelectronics.
Collapse
Affiliation(s)
- Hyunjoon Yoo
- National Creative Research Initiative for Functionally Antagonistic Nano-Engineering, Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon, 34141, Republic of Korea
| | - Manmatha Mahato
- National Creative Research Initiative for Functionally Antagonistic Nano-Engineering, Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon, 34141, Republic of Korea
| | - Woong Oh
- National Creative Research Initiative for Functionally Antagonistic Nano-Engineering, Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon, 34141, Republic of Korea
| | - Jawon Ha
- National Creative Research Initiative for Functionally Antagonistic Nano-Engineering, Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon, 34141, Republic of Korea
| | - Hee Han
- National Nanofab Center (NNFC), Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon, 34141, Republic of Korea
| | - Chi Won Ahn
- National Nanofab Center (NNFC), Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon, 34141, Republic of Korea.
| | - Il-Kwon Oh
- National Creative Research Initiative for Functionally Antagonistic Nano-Engineering, Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon, 34141, Republic of Korea.
| |
Collapse
|
2
|
Mariello M, Eş I, Proctor CM. Soft and Flexible Bioelectronic Micro-Systems for Electronically Controlled Drug Delivery. Adv Healthc Mater 2024; 13:e2302969. [PMID: 37924224 DOI: 10.1002/adhm.202302969] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2023] [Revised: 10/20/2023] [Indexed: 11/06/2023]
Abstract
The concept of targeted and controlled drug delivery, which directs treatment to precise anatomical sites, offers benefits such as fewer side effects, reduced toxicity, optimized dosages, and quicker responses. However, challenges remain to engineer dependable systems and materials that can modulate host tissue interactions and overcome biological barriers. To stay aligned with advancements in healthcare and precision medicine, novel approaches and materials are imperative to improve effectiveness, biocompatibility, and tissue compliance. Electronically controlled drug delivery (ECDD) has recently emerged as a promising approach to calibrated drug delivery with spatial and temporal precision. This article covers recent breakthroughs in soft, flexible, and adaptable bioelectronic micro-systems designed for ECDD. It overviews the most widely reported operational modes, materials engineering strategies, electronic interfaces, and characterization techniques associated with ECDD systems. Further, it delves into the pivotal applications of ECDD in wearable, ingestible, and implantable medical devices. Finally, the discourse extends to future prospects and challenges for ECDD.
Collapse
Affiliation(s)
- Massimo Mariello
- Department of Engineering Science, Institute of Biomedical Engineering (IBME), University of Oxford, Oxford, OX3 7DQ, UK
| | - Ismail Eş
- Department of Engineering Science, Institute of Biomedical Engineering (IBME), University of Oxford, Oxford, OX3 7DQ, UK
| | - Christopher M Proctor
- Department of Engineering Science, Institute of Biomedical Engineering (IBME), University of Oxford, Oxford, OX3 7DQ, UK
| |
Collapse
|
3
|
Souri M, Elahi S, Soltani M. Programmable intratumoral drug delivery to breast cancer using wireless bioelectronic device with electrochemical actuation. Expert Opin Drug Deliv 2024; 21:495-511. [PMID: 38396366 DOI: 10.1080/17425247.2024.2323211] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2023] [Accepted: 02/14/2024] [Indexed: 02/25/2024]
Abstract
OBJECTIVE Breast cancer is a global health concern that demands attention. In our contribution to addressing this disease, our study focuses on investigating a wireless micro-device for intratumoral drug delivery, utilizing electrochemical actuation. Microdevices have emerged as a promising approach in this field due to their ability to enable controlled injections in various applications. METHODS Our study is conducted within a computational framework, employing models that simulate the behavior of the microdevice and drug discharge based on the principles of the ideal gas law. Furthermore, the distribution of the drug within the tissue is simulated, considering both diffusion and convection mechanisms. To predict the therapeutic response, a pharmacodynamic model is utilized, considering the chemotherapeutic effects and cell proliferation. RESULTS The findings demonstrate that an effective current of 3 mA, along with an initial gas volume equal to the drug volume in the microdevice, optimizes drug delivery. Microdevices with multiple injection capabilities exhibit enhanced therapeutic efficacy, effectively suppressing cell proliferation. Additionally, tumors with lower microvascular density experience higher drug concentrations in the extracellular space, resulting in significant cell death in hypoxic regions. CONCLUSIONS Achieving an efficient therapeutic response involves considering both the characteristics of the tumor microenvironment and the frequency of injections within a specific time frame.
Collapse
Affiliation(s)
- Mohammad Souri
- Department of NanoBiotechnology, Pasteur Institute of Iran, Tehran, Iran
| | - Sohail Elahi
- Department of Mechanical Engineering, K. N. Toosi University of Technology, Tehran, Iran
| | - Madjid Soltani
- Department of Mechanical Engineering, K. N. Toosi University of Technology, Tehran, Iran
- Department of Electrical and Computer Engineering, University of Waterloo, Waterloo, Ontario, Canada
- Centre for Biotechnology and Bioengineering (CBB), University of Waterloo, Waterloo, Ontario, Canada
- Department of Integrative Oncology, BC Cancer Research Institute, Vancouver, British Columbia, Canada
| |
Collapse
|
4
|
Rsetam K, Al-Rawi M, Cao Z, Alsadoon A, Wang L. Model based smooth super-twisting control of cancer chemotherapy treatment. Comput Biol Med 2024; 169:107957. [PMID: 38190767 DOI: 10.1016/j.compbiomed.2024.107957] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2023] [Revised: 12/11/2023] [Accepted: 01/01/2024] [Indexed: 01/10/2024]
Abstract
Chemotherapy is one of the most efficient methods for treating cancer patients. Chemotherapy aims to eliminate cancer cells as thoroughly as possible. Delivering medications to patients' bodies through various methods, either oral or intravenous is part of the chemotherapy process. Different cell-kill hypotheses take into account the interactions of the expansion of the tumor volume, external drugs, and the rate of their eradication. For the control of drug usage and tumor volume, a model based smooth super-twisting control (MBSSTC) is proposed in this paper. Firstly, three nonlinear cell-kill mathematical models are considered in this work, including the log-kill, Norton-Simon, and Emax hypotheses subject to parametric uncertainties and exogenous perturbations. In accordance with clinical recommendations, the tumor volume follows a predefined trajectory after chemotherapy. Secondly, the MBSSTC is applied for the three cell-kill models to attain accurate trajectory tracking even in the presence of uncertainties and disturbances. Compared to conventional super-twisting control (STC), the non-smooth term is introduced in the proposed control to enhance the anti-disturbance capability. Finally, simulation comparisons are performed across the proposed MBSSTC, conventional STC, and proportional-integral (PI) control methods to show the effectiveness and merits of our designed control method.
Collapse
Affiliation(s)
- Kamal Rsetam
- Al Khwarizmi College of Engineering, University of Baghdad, Baghdad, Iraq; School of Science, Computing and Engineering Technologies, Swinburne University of Technology, Melbourne, 3122, Australia.
| | - Mohammad Al-Rawi
- Faculty of Engineering, Chemical and Materials Engineering, The University of Auckland, Auckland, New Zealand; Centre for Engineering and Industrial Design, Waikato Institute of Technology, Hamilton, New Zealand.
| | - Zhenwei Cao
- School of Science, Computing and Engineering Technologies, Swinburne University of Technology, Melbourne, 3122, Australia.
| | - Abeer Alsadoon
- School of Computing Mathematics and Engineering, Charles Sturt University (CSU), Wagga Wagga, Australia; Asia Pacific International College (APIC), Sydney, Australia.
| | - Lulu Wang
- Biomedical Device Innovation Center, Shenzhen Technology University, Shenzhen 518118, China.
| |
Collapse
|
5
|
Zheng Y, Zheng G, Li YY, Gong X, Chen Z, Zhu L, Xu Y, Xie X, Wu S, Jiang L. Implantable magnetically-actuated capsule for on-demand delivery. J Control Release 2023; 364:576-588. [PMID: 37951475 DOI: 10.1016/j.jconrel.2023.11.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2023] [Revised: 10/08/2023] [Accepted: 11/07/2023] [Indexed: 11/14/2023]
Abstract
Many implantable drug delivery systems (IDDS) have been developed for long-term, pulsatile drug release. However, they are often limited by bulky size, complex electronic components, unpredictable drug delivery, as well as the need for battery replacement and consequent replacement surgery. Here, we develop an implantable magnetically-actuated capsule (IMAC) and its portable magnetic actuator (MA) for on-demand and robust drug delivery in a tether-free and battery-free manner. IMAC utilizes the bistable mechanism of two magnetic balls inside IMAC to trigger drug delivery under a strong magnetic field (|Ba| > 90 mT), ensuring precise and reproducible drug delivery (9.9 ± 0.17 μg per actuation, maximum actuation number: 180) and excellent anti-magnetic capability (critical trigger field intensity: ∼90 mT). IMAC as a tetherless robot can navigate to and anchor at the lesion sites driven by a gradient magnetic field (∇ Bg = 3 T/m, |Bg| < 60 mT), and on-demand release drug actuated by a uniform magnetic field (|Ba| = ∼100 mT) within the gastrointestinal tract. During a 15-day insulin administration in vivo, the diabetic rats treated with IMAC exhibited highly similar pharmacokinetic and pharmacodynamic profiles to those administrated via subcutaneous injection, demonstrating its robust and on-demand drug release performance. Moreover, IMAC is biocompatible, batter-free, refillable, miniature (only Φ 6.3 × 12.3 mm3), and lightweight (just 0.8 g), making it an ideal alternative for precise implantable drug delivery and friendly patient-centered drug administration.
Collapse
Affiliation(s)
- Ying Zheng
- Guangdong Provincial Key Laboratory of Sensor Technology and Biomedical Instrument, School of Biomedical Engineering, Shenzhen Campus of Sun Yat-Sen University, Shenzhen 518107, China
| | - Guizhou Zheng
- Guangdong Provincial Key Laboratory of Sensor Technology and Biomedical Instrument, School of Biomedical Engineering, Shenzhen Campus of Sun Yat-Sen University, Shenzhen 518107, China
| | - Yuan Yuan Li
- Guangdong Provincial Key Laboratory of Sensor Technology and Biomedical Instrument, School of Biomedical Engineering, Shenzhen Campus of Sun Yat-Sen University, Shenzhen 518107, China
| | - Xia Gong
- Guangdong Provincial Key Laboratory of Sensor Technology and Biomedical Instrument, School of Biomedical Engineering, Shenzhen Campus of Sun Yat-Sen University, Shenzhen 518107, China
| | - Zhipeng Chen
- School of Mechanical and Electrical Engineering, Guangzhou University, Guangzhou 510006, China
| | - Linyu Zhu
- The 7(th) Affiliated Hospital, Sun Yat-sen University, Shenzhen 518107, China
| | - Yunsheng Xu
- The 7(th) Affiliated Hospital, Sun Yat-sen University, Shenzhen 518107, China
| | - Xi Xie
- State Key Laboratory of Optoelectronic Materials and Technologies, School of Electronics and Information Technology, Sun Yat-sen University, Guangzhou 510006, China
| | - Shuo Wu
- Guangdong Provincial Key Laboratory of Sensor Technology and Biomedical Instrument, School of Biomedical Engineering, Shenzhen Campus of Sun Yat-Sen University, Shenzhen 518107, China; The 3(rd) Affiliated Hospital, Sun Yat-Sen University, Guangzhou 510630, China..
| | - Lelun Jiang
- Guangdong Provincial Key Laboratory of Sensor Technology and Biomedical Instrument, School of Biomedical Engineering, Shenzhen Campus of Sun Yat-Sen University, Shenzhen 518107, China.
| |
Collapse
|
6
|
Huang H, Lyu Y, Nan K. Soft robot-enabled controlled release of oral drug formulations. SOFT MATTER 2023; 19:1269-1281. [PMID: 36723379 DOI: 10.1039/d2sm01624a] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/18/2023]
Abstract
The creation of highly effective oral drug delivery systems (ODDSs) has long been the main objective of pharmaceutical research. Multidisciplinary efforts involving materials, electronics, control, and pharmaceutical sciences encourage the development of robot-enabled ODDSs. Compared with conventional rigid robots, soft robots potentially offer better mechanical compliance and biocompatibility with biological tissues, more versatile shape control and maneuverability, and multifunctionality. In this paper, we first describe and highlight the importance of manipulating drug release kinetics, i.e. pharmaceutical kinetics. We then introduce an overview of state-of-the-art soft robot-based ODDSs comprising resident, shape-programming, locomotive, and integrated soft robots. Finally, the challenges and outlook regarding future soft robot-based ODDS development are discussed.
Collapse
Affiliation(s)
- Hao Huang
- College of Chemical and Biological Engineering, Zhejiang University, Hangzhou 310058, China
| | - Yidan Lyu
- College of Pharmaceutical Sciences, Zhejiang University, Hangzhou 310058, China.
| | - Kewang Nan
- College of Pharmaceutical Sciences, Zhejiang University, Hangzhou 310058, China.
| |
Collapse
|
7
|
Liu Y, Yu Q, Ye L, Yang L, Cui Y. A wearable, minimally-invasive, fully electrochemically-controlled feedback minisystem for diabetes management. LAB ON A CHIP 2023; 23:421-436. [PMID: 36597970 DOI: 10.1039/d2lc00797e] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/17/2023]
Abstract
Diabetes is a chronic disease affecting 10% of the population globally, and can lead to serious damage in the heart, kidneys, eyes, blood vessels or nerves. Commercial artificial closed-loop feedback systems can significantly improve diabetes management and save lives. However, they are large and expensive for users. Here, we demonstrate for the first time a wearable, minimally-invasive, fully electrochemically-controlled feedback minisystem for diabetes management. Both the working principles of the sensor and pump in the feedback system are based on electrochemical reactions. The smart minisystem was constructed based on integrating the thermoplastic polyurethane hollow microneedles with an electrochemical biosensing device on its outer layer and an electrochemical micropump facing the inner layer of the microneedles. The sensing device was constructed based on sputtering thin metal films through a shadow mask and electroplating Prussian blue on the surface of the microneedles, followed by the immobilization of glucose oxidase on the working electrode. The electrochemical micropump was constructed by sputtering the interdigital electrodes, followed by sealing with a thin elastic film, which was further integrated with the inner channels of the microneedles. Both the sensor and the pump were electrically powered. Via being controlled by a printed circuit board, the biosensing device monitored the levels of interstitial glucose continuously to drive the electrochemical pump to deliver insulin intelligently, in order to control blood glucose within the normal range. The closed-loop feedback system was studied for its capability in maintaining the blood glucose levels of diabetic rats under various physiological conditions. The utility of the intelligent feedback system was successfully demonstrated on diabetic rats for controlling the blood glucose levels within the normal range. The minisystem is wearable, small, cost-effective, precise, stable and painless. It is anticipated that this approach opens a new paradigm for the development of closed-loop diabetes minisystems and may lead to a compelling future for diabetes management.
Collapse
Affiliation(s)
- Yiqun Liu
- School of Materials Science and Engineering, Peking University, First Hospital Interdisciplinary Research Center, Peking University, Beijing 100871, P.R. China.
| | - Qi Yu
- Renal Division, Peking University First Hospital, Peking University Institute of Nephrology, Key Laboratory of Renal Disease, Ministry of Health of China, Key Laboratory of Chronic Kidney Disease Prevention and Treatment (Peking University), Ministry of Education, Beijing 100034, P.R. China.
| | - Le Ye
- Institute of Microelectronics, Peking University, Beijing 100871, P.R. China
| | - Li Yang
- Renal Division, Peking University First Hospital, Peking University Institute of Nephrology, Key Laboratory of Renal Disease, Ministry of Health of China, Key Laboratory of Chronic Kidney Disease Prevention and Treatment (Peking University), Ministry of Education, Beijing 100034, P.R. China.
| | - Yue Cui
- School of Materials Science and Engineering, Peking University, First Hospital Interdisciplinary Research Center, Peking University, Beijing 100871, P.R. China.
| |
Collapse
|
8
|
Kim CR, Cho YC, Lee SH, Han JH, Kim MJ, Ji HB, Kim S, Min CH, Shin BH, Lee C, Cho YM, Choy YB. Implantable device actuated by manual button clicks for noninvasive self-drug administration. Bioeng Transl Med 2023; 8:e10320. [PMID: 36684080 PMCID: PMC9842066 DOI: 10.1002/btm2.10320] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2022] [Revised: 03/10/2022] [Accepted: 03/11/2022] [Indexed: 02/01/2023] Open
Abstract
Self-injectable therapy has several advantages in the treatment of metabolic disorders. However, frequent injections with needles impair patient compliance and medication adherence. Therefore, we develop a fully implantable device capable of on-demand administration of self-injection drugs via noninvasive manual button clicks on the outer skin. The device is designed to infuse the drug only at the moment of click actuation, which allows for an accurate and reproducible drug infusion, and also prevents unwanted drug leakage. Using a mechanical means of drug infusion, this implantable device does not contain any electronic compartments or batteries, making it compact, and semi-permanent. When tested in animals, the device can achieve subcutaneous injection-like pharmacokinetic and pharmacodynamic effects for self-injection drugs such as exenatide, insulin, and glucagon.
Collapse
Affiliation(s)
- Cho Rim Kim
- Interdisciplinary Program in Bioengineering, College of EngineeringSeoul National UniversitySeoulSouth Korea
| | - Yong Chan Cho
- Interdisciplinary Program in Bioengineering, College of EngineeringSeoul National UniversitySeoulSouth Korea
| | - Seung Ho Lee
- Institute of Medical and Biological Engineering, Medical Research CenterSeoul National UniversitySeoulSouth Korea
| | - Jae Hoon Han
- Interdisciplinary Program in Bioengineering, College of EngineeringSeoul National UniversitySeoulSouth Korea
| | - Min Ji Kim
- Interdisciplinary Program in Bioengineering, College of EngineeringSeoul National UniversitySeoulSouth Korea
| | - Han Bi Ji
- Interdisciplinary Program in Bioengineering, College of EngineeringSeoul National UniversitySeoulSouth Korea
| | - Se‐Na Kim
- Institute of Medical and Biological Engineering, Medical Research CenterSeoul National UniversitySeoulSouth Korea
| | - Chang Hee Min
- Institute of Medical and Biological Engineering, Medical Research CenterSeoul National UniversitySeoulSouth Korea
| | - Byung Ho Shin
- Department of Biomedical EngineeringSeoul National University College of MedicineSeoulSouth Korea
| | - Cheol Lee
- Department of PathologySeoul National University College of MedicineSeoulSouth Korea
| | - Young Min Cho
- Department of Internal MedicineSeoul National University College of MedicineSeoulSouth Korea
- Department of Translational Medicine, College of MedicineSeoul National UniversitySeoulSouth Korea
| | - Young Bin Choy
- Interdisciplinary Program in Bioengineering, College of EngineeringSeoul National UniversitySeoulSouth Korea
- Institute of Medical and Biological Engineering, Medical Research CenterSeoul National UniversitySeoulSouth Korea
- Department of Biomedical EngineeringSeoul National University College of MedicineSeoulSouth Korea
| |
Collapse
|
9
|
Busnatu ȘS, Niculescu AG, Bolocan A, Andronic O, Pantea Stoian AM, Scafa-Udriște A, Stănescu AMA, Păduraru DN, Nicolescu MI, Grumezescu AM, Jinga V. A Review of Digital Health and Biotelemetry: Modern Approaches towards Personalized Medicine and Remote Health Assessment. J Pers Med 2022; 12:1656. [PMID: 36294795 PMCID: PMC9604784 DOI: 10.3390/jpm12101656] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2022] [Revised: 09/28/2022] [Accepted: 09/30/2022] [Indexed: 11/05/2022] Open
Abstract
With the prevalence of digitalization in all aspects of modern society, health assessment is becoming digital too. Taking advantage of the most recent technological advances and approaching medicine from an interdisciplinary perspective has allowed for important progress in healthcare services. Digital health technologies and biotelemetry devices have been more extensively employed for preventing, detecting, diagnosing, monitoring, and predicting the evolution of various diseases, without requiring wires, invasive procedures, or face-to-face interaction with medical personnel. This paper aims to review the concepts correlated to digital health, classify and describe biotelemetry devices, and present the potential of digitalization for remote health assessment, the transition to personalized medicine, and the streamlining of clinical trials.
Collapse
Affiliation(s)
- Ștefan Sebastian Busnatu
- Department of Cardiology, University of Medicine and Pharmacy “Carol Davila”, 050474 Bucharest, Romania
| | - Adelina-Gabriela Niculescu
- Department of Science and Engineering of Oxide Materials and Nanomaterials, Politehnica University of Bucharest, 011061 Bucharest, Romania
| | - Alexandra Bolocan
- Department of Cardiology, University of Medicine and Pharmacy “Carol Davila”, 050474 Bucharest, Romania
| | - Octavian Andronic
- Department of Cardiology, University of Medicine and Pharmacy “Carol Davila”, 050474 Bucharest, Romania
| | | | - Alexandru Scafa-Udriște
- Department of Cardiology, University of Medicine and Pharmacy “Carol Davila”, 050474 Bucharest, Romania
| | | | - Dan Nicolae Păduraru
- Department of Cardiology, University of Medicine and Pharmacy “Carol Davila”, 050474 Bucharest, Romania
| | - Mihnea Ioan Nicolescu
- Department of Cardiology, University of Medicine and Pharmacy “Carol Davila”, 050474 Bucharest, Romania
| | - Alexandru Mihai Grumezescu
- Department of Science and Engineering of Oxide Materials and Nanomaterials, Politehnica University of Bucharest, 011061 Bucharest, Romania
- Research Institute of the University of Bucharest—ICUB, University of Bucharest, 050657 Bucharest, Romania
- Academy of Romanian Scientists, Ilfov No. 3, 050044 Bucharest, Romania
| | - Viorel Jinga
- Department of Cardiology, University of Medicine and Pharmacy “Carol Davila”, 050474 Bucharest, Romania
| |
Collapse
|
10
|
Lee SH, Kim CR, Cho YC, Kim SN, Kim BH, Lee C, Ji HB, Han JH, Park CG, Hong H, Choy YB. Magnetically actuating implantable pump for the on-demand and needle-free administration of human growth hormone. Int J Pharm 2022; 618:121664. [PMID: 35292393 DOI: 10.1016/j.ijpharm.2022.121664] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2022] [Revised: 03/03/2022] [Accepted: 03/10/2022] [Indexed: 11/28/2022]
Abstract
A bolus of human growth hormone (hGH) is often prescribed for the treatment of growth hormone deficiency, which requires frequent injections in current clinical settings. This painful needle-involved delivery often results in poor patient compliance, leading to low medication adherence and poor clinical outcomes. Therefore, we propose a magnetically actuating implantable pump (MAP) that can infuse an accurate dose of hGH only at the time of non-invasive magnet application from the skin. The MAP herein could reproducibly infuse 20.6 ± 0.9 μg hGH per actuation without any leak at times without actuation. The infused amount increased proportionally with an increase in the number of actuations. When the MAP was implanted and actuated with a magnet in animals with growth hormone deficiency for 21 days, the profiles of plasma hGH concentration and insulin-like growth factor (IGF)-1, as well as changes in body weight, were similar to those observed in animals treated with conventional subcutaneous hGH injections. Therefore, we anticipate that the MAP fabricated in this study can be a non-invasive alternative to administer hGH without repeated and frequent needle injections.
Collapse
Affiliation(s)
- Seung Ho Lee
- Institute of Medical & Biological Engineering, Medical Research Center, Seoul National University, Seoul 03080, Republic of Korea
| | - Cho Rim Kim
- Interdisciplinary Program in Bioengineering, College of Engineering, Seoul National University, Seoul 08826, Republic of Korea
| | - Yong Chan Cho
- Interdisciplinary Program in Bioengineering, College of Engineering, Seoul National University, Seoul 08826, Republic of Korea
| | - Se-Na Kim
- Institute of Medical & Biological Engineering, Medical Research Center, Seoul National University, Seoul 03080, Republic of Korea
| | - Byung Hwi Kim
- Department of Biomedical Engineering, Seoul National University College of Medicine, Seoul 03080, Republic of Korea
| | - Cheol Lee
- Department of Pathology, Seoul National University College of Medicine, Seoul 03080, Republic of Korea
| | - Han Bi Ji
- Interdisciplinary Program in Bioengineering, College of Engineering, Seoul National University, Seoul 08826, Republic of Korea
| | - Jae Hoon Han
- Interdisciplinary Program in Bioengineering, College of Engineering, Seoul National University, Seoul 08826, Republic of Korea
| | - Chun Gwon Park
- Department of Biomedical Engineering, SKKU Institute for Convergence, Sungkyunkwan University (SKKU), Suwon 16419, Republic of Korea
| | - HyeonJi Hong
- Department of Biomedical Engineering, Seoul National University College of Medicine, Seoul 03080, Republic of Korea
| | - Young Bin Choy
- Institute of Medical & Biological Engineering, Medical Research Center, Seoul National University, Seoul 03080, Republic of Korea; Interdisciplinary Program in Bioengineering, College of Engineering, Seoul National University, Seoul 08826, Republic of Korea; Department of Biomedical Engineering, Seoul National University College of Medicine, Seoul 03080, Republic of Korea.
| |
Collapse
|
11
|
Avila R, Wu Y, Garziera R, Rogers JA, Huang Y. Analytical Modeling of Flowrate and Its Maxima in Electrochemical Bioelectronics with Drug Delivery Capabilities. RESEARCH (WASHINGTON, D.C.) 2022; 2022:9805932. [PMID: 35316891 PMCID: PMC8917966 DOI: 10.34133/2022/9805932] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/27/2021] [Accepted: 02/16/2022] [Indexed: 11/06/2022]
Abstract
Flowrate control in flexible bioelectronics with targeted drug delivery capabilities is essential to ensure timely and safe delivery. For neuroscience and pharmacogenetics studies in small animals, these flexible bioelectronic systems can be tailored to deliver small drug volumes on a controlled fashion without damaging surrounding tissues from stresses induced by excessively high flowrates. The drug delivery process is realized by an electrochemical reaction that pressurizes the internal bioelectronic chambers to deform a flexible polymer membrane that pumps the drug through a network of microchannels implanted in the small animal. The flowrate temporal profile and global maximum are governed and can be modeled by the ideal gas law. Here, we obtain an analytical solution that groups the relevant mechanical, fluidic, environmental, and electrochemical terms involved in the drug delivery process into a set of three nondimensional parameters. The unique combinations of these three nondimensional parameters (related to the initial pressure, initial gas volume, and microfluidic resistance) can be used to model the flowrate and scale up the flexible bioelectronic design for experiments in medium and large animal models. The analytical solution is divided into (1) a fast variable that controls the maximum flowrate and (2) a slow variable that models the temporal profile. Together, the two variables detail the complete drug delivery process and control using the three nondimensional parameters. Comparison of the analytical model with alternative numerical models shows excellent agreement and validates the analytic modeling approach. These findings serve as a theoretical framework to design and optimize future flexible bioelectronic systems used in biomedical research, or related medical fields, and analytically control the flowrate and its global maximum for successful drug delivery.
Collapse
Affiliation(s)
- Raudel Avila
- Department of Mechanical Engineering, Northwestern University, Evanston, IL 60208, USA
| | - Yixin Wu
- Department of Materials Science and Engineering, Northwestern University, Evanston, IL 60208, USA.,Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL 60208, USA
| | - Rinaldo Garziera
- Dipartimento di Ingegneria ed Architettura, Università di Parma, Italy
| | - John A Rogers
- Department of Mechanical Engineering, Northwestern University, Evanston, IL 60208, USA.,Department of Materials Science and Engineering, Northwestern University, Evanston, IL 60208, USA.,Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL 60208, USA.,Department of Biomedical Engineering, Northwestern University, Evanston, IL 60208, USA.,Department of Electrical and Computer Engineering, Northwestern University, Evanston, IL 60208, USA.,Department of Chemistry, Northwestern University, Evanston, IL 60208, USA.,Department of Neurological Surgery, Northwestern University, Feinberg School of Medicine, Chicago, IL 60611, USA
| | - Yonggang Huang
- Department of Mechanical Engineering, Northwestern University, Evanston, IL 60208, USA.,Department of Materials Science and Engineering, Northwestern University, Evanston, IL 60208, USA.,Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL 60208, USA.,Department of Civil and Environmental Engineering, Northwestern University, Evanston, IL 60208, USA
| |
Collapse
|
12
|
Fast Electrochemical Actuator with Ti Electrodes in the Current Stabilization Regime. MICROMACHINES 2022; 13:mi13020283. [PMID: 35208407 PMCID: PMC8877286 DOI: 10.3390/mi13020283] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/13/2022] [Revised: 02/07/2022] [Accepted: 02/08/2022] [Indexed: 02/01/2023]
Abstract
The actuators needed for autonomous microfluidic devices have to be compact, low-power-consuming, and compatible with microtechnology. The electrochemical actuators could be good candidates, but they suffer from a long response time due to slow gas termination. An actuator in which the gas is terminated orders of magnitude faster has been demonstrated recently. It uses water electrolysis performed by short voltage pulses of alternating polarity (AP). However, oxidation of Ti electrodes leads to a rapid decrease in the performance. In this paper, we demonstrate a special driving regime of the actuator, which is able to support a constant stroke for at least 105 cycles. The result is achieved using a new driving regime when a series of AP pulses are interspersed with a series of single-polarity (SP) pulses. The new regime is realized by a special pulse generator that automatically adjusts the amplitude of the SP pulses to keep the current flowing through the electrodes at a fixed level. The SP pulses increase the power consumption by 15–60% compared to the normal AP operation and make the membrane oscillate in a slightly lifted position.
Collapse
|
13
|
González-Fernández E, Staderini M, Marland JRK, Gray ME, Uçar A, Dunare C, Blair EO, Sullivan P, Tsiamis A, Greenhalgh SN, Gregson R, Clutton RE, Smith S, Terry JG, Argyle DJ, Walton AJ, Mount AR, Bradley M, Murray AF. In vivo application of an implantable tri-anchored methylene blue-based electrochemical pH sensor. Biosens Bioelectron 2022; 197:113728. [PMID: 34763151 DOI: 10.1016/j.bios.2021.113728] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2021] [Revised: 10/06/2021] [Accepted: 10/21/2021] [Indexed: 12/13/2022]
Abstract
The development of robust implantable sensors is important in the successful advancement of personalised medicine as they have the potential to provide in situ real-time data regarding the status of health and disease and the effectiveness of treatment. Tissue pH is a key physiological parameter and herein, we report the design, fabrication, functionalisation, encapsulation and protection of a miniaturised, self-contained, electrochemical pH sensor system and characterisation of sensor performance. Notably for the first time in this environment the pH sensor was based on a methylene blue redox reporter which showed remarkable robustness, accuracy and sensitivity. This was achieved by encapsulation of a self-assembled monolayer containing methylene blue entrapped within a Nafion layer. Another powerful feature was the incorporation, within the same implanted device, of a fabricated on-chip Ag/AgCl reference electrode - vital in any electrochemical sensor, but often ignored. When utilised in vivo, the sensor allowed accurate tracking of externally induced pH changes within a naturally occurring ovine lung cancer model, and correlated well with single point laboratory measurements made on extracted arterial blood, whilst enabling in vivo time-dependent measurements. The sensors functioned robustly whilst implanted, and maintained in vitro function once extracted and together, these results demonstrate proof-of-concept of the ability to sense real-time intratumoral tissue pH changes in vivo.
Collapse
Affiliation(s)
- Eva González-Fernández
- EaStCHEM, School of Chemistry, University of Edinburgh, Joseph Black Building, West Mains Road, Edinburgh, EH9 3FJ, UK
| | - Matteo Staderini
- EaStCHEM, School of Chemistry, University of Edinburgh, Joseph Black Building, West Mains Road, Edinburgh, EH9 3FJ, UK
| | - Jamie R K Marland
- School of Engineering, Institute for Integrated Micro and Nano Systems, University of Edinburgh, Scottish Microelectronics Centre, The King's Buildings, Edinburgh, EH9 3FF, UK
| | - Mark E Gray
- The Royal (Dick) School of Veterinary Studies and Roslin Institute, University of Edinburgh, Easter Bush, Roslin, Midlothian, EH25 9RG, UK
| | - Ahmet Uçar
- EaStCHEM, School of Chemistry, University of Edinburgh, Joseph Black Building, West Mains Road, Edinburgh, EH9 3FJ, UK; School of Engineering, Institute for Bioengineering, University of Edinburgh, Faraday Building, The King's Buildings, Edinburgh, EH9 3DW, UK; Department of Biomedical Engineering, Faculty of Engineering and Natural Sciences, Ankara Yildirim Beyazıt University, 06010 Ankara, Turkey
| | - Camelia Dunare
- School of Engineering, Institute for Integrated Micro and Nano Systems, University of Edinburgh, Scottish Microelectronics Centre, The King's Buildings, Edinburgh, EH9 3FF, UK
| | - Ewen O Blair
- School of Engineering, Institute for Integrated Micro and Nano Systems, University of Edinburgh, Scottish Microelectronics Centre, The King's Buildings, Edinburgh, EH9 3FF, UK
| | - Paul Sullivan
- School of Engineering, Institute for Bioengineering, University of Edinburgh, Faraday Building, The King's Buildings, Edinburgh, EH9 3DW, UK
| | - Andreas Tsiamis
- School of Engineering, Institute for Bioengineering, University of Edinburgh, Faraday Building, The King's Buildings, Edinburgh, EH9 3DW, UK
| | - Stephen N Greenhalgh
- The Royal (Dick) School of Veterinary Studies and Roslin Institute, University of Edinburgh, Easter Bush, Roslin, Midlothian, EH25 9RG, UK
| | - Rachael Gregson
- The Royal (Dick) School of Veterinary Studies and Roslin Institute, University of Edinburgh, Easter Bush, Roslin, Midlothian, EH25 9RG, UK
| | - Richard Eddie Clutton
- The Royal (Dick) School of Veterinary Studies and Roslin Institute, University of Edinburgh, Easter Bush, Roslin, Midlothian, EH25 9RG, UK
| | - Stewart Smith
- School of Engineering, Institute for Bioengineering, University of Edinburgh, Faraday Building, The King's Buildings, Edinburgh, EH9 3DW, UK
| | - Jonathan G Terry
- School of Engineering, Institute for Integrated Micro and Nano Systems, University of Edinburgh, Scottish Microelectronics Centre, The King's Buildings, Edinburgh, EH9 3FF, UK
| | - David J Argyle
- The Royal (Dick) School of Veterinary Studies and Roslin Institute, University of Edinburgh, Easter Bush, Roslin, Midlothian, EH25 9RG, UK
| | - Anthony J Walton
- School of Engineering, Institute for Integrated Micro and Nano Systems, University of Edinburgh, Scottish Microelectronics Centre, The King's Buildings, Edinburgh, EH9 3FF, UK
| | - Andrew R Mount
- EaStCHEM, School of Chemistry, University of Edinburgh, Joseph Black Building, West Mains Road, Edinburgh, EH9 3FJ, UK.
| | - Mark Bradley
- EaStCHEM, School of Chemistry, University of Edinburgh, Joseph Black Building, West Mains Road, Edinburgh, EH9 3FJ, UK.
| | - Alan F Murray
- School of Engineering, Institute for Bioengineering, University of Edinburgh, Faraday Building, The King's Buildings, Edinburgh, EH9 3DW, UK.
| |
Collapse
|
14
|
Modeling programmable drug delivery in bioelectronics with electrochemical actuation. Proc Natl Acad Sci U S A 2021; 118:2026405118. [PMID: 33836613 DOI: 10.1073/pnas.2026405118] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023] Open
Abstract
Drug delivery systems featuring electrochemical actuation represent an emerging class of biomedical technology with programmable volume/flowrate capabilities for localized delivery. Recent work establishes applications in neuroscience experiments involving small animals in the context of pharmacological response. However, for programmable delivery, the available flowrate control and delivery time models fail to consider key variables of the drug delivery system--microfluidic resistance and membrane stiffness. Here we establish an analytical model that accounts for the missing variables and provides a scalable understanding of each variable influence in the physics of delivery process (i.e., maximum flowrate, delivery time). This analytical model accounts for the key parameters--initial environmental pressure, initial volume, microfluidic resistance, flexible membrane, current, and temperature--to control the delivery and bypasses numerical simulations allowing faster system optimization for different in vivo experiments. We show that the delivery process is controlled by three nondimensional parameters, and the volume/flowrate results from the proposed analytical model agree with the numerical results and experiments. These results have relevance to the many emerging applications of programmable delivery in clinical studies within the neuroscience and broader biomedical communities.
Collapse
|
15
|
Liu Y, Sun L, Zhang H, Shang L, Zhao Y. Microfluidics for Drug Development: From Synthesis to Evaluation. Chem Rev 2021; 121:7468-7529. [PMID: 34024093 DOI: 10.1021/acs.chemrev.0c01289] [Citation(s) in RCA: 79] [Impact Index Per Article: 19.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
Drug development is a long process whose main content includes drug synthesis, drug delivery, and drug evaluation. Compared with conventional drug development procedures, microfluidics has emerged as a revolutionary technology in that it offers a miniaturized and highly controllable environment for bio(chemical) reactions to take place. It is also compatible with analytical strategies to implement integrated and high-throughput screening and evaluations. In this review, we provide a comprehensive summary of the entire microfluidics-based drug development system, from drug synthesis to drug evaluation. The challenges in the current status and the prospects for future development are also discussed. We believe that this review will promote communications throughout diversified scientific and engineering communities that will continue contributing to this burgeoning field.
Collapse
Affiliation(s)
- Yuxiao Liu
- Department of Rheumatology and Immunology, Institute of Translational Medicine, The Affiliated Drum Tower Hospital of Nanjing University Medical School, Nanjing 210008, China.,State Key Laboratory of Bioelectronics, School of Biological Science and Medical Engineering, Southeast University, Nanjing 210096, China
| | - Lingyu Sun
- Department of Rheumatology and Immunology, Institute of Translational Medicine, The Affiliated Drum Tower Hospital of Nanjing University Medical School, Nanjing 210008, China.,State Key Laboratory of Bioelectronics, School of Biological Science and Medical Engineering, Southeast University, Nanjing 210096, China
| | - Hui Zhang
- Department of Rheumatology and Immunology, Institute of Translational Medicine, The Affiliated Drum Tower Hospital of Nanjing University Medical School, Nanjing 210008, China.,State Key Laboratory of Bioelectronics, School of Biological Science and Medical Engineering, Southeast University, Nanjing 210096, China
| | - Luoran Shang
- Zhongshan-Xuhui Hospital, and the Shanghai Key Laboratory of Medical Epigenetics, the International Co-laboratory of Medical Epigenetics and Metabolism, Ministry of Science and Technology, Institutes of Biomedical Sciences, Fudan University, Shanghai, China
| | - Yuanjin Zhao
- Department of Rheumatology and Immunology, Institute of Translational Medicine, The Affiliated Drum Tower Hospital of Nanjing University Medical School, Nanjing 210008, China.,State Key Laboratory of Bioelectronics, School of Biological Science and Medical Engineering, Southeast University, Nanjing 210096, China
| |
Collapse
|
16
|
Shape Memory Alloy Capsule Micropump for Drug Delivery Applications. MICROMACHINES 2021; 12:mi12050520. [PMID: 34066315 PMCID: PMC8148152 DOI: 10.3390/mi12050520] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/31/2021] [Revised: 04/17/2021] [Accepted: 04/27/2021] [Indexed: 11/17/2022]
Abstract
We introduce a shape memory alloy (SMA) actuated micropump optimized for drug delivery applications. The proposed novel design integrates a built-in replaceable drug reservoir within the pump package forming a self-contained preloaded capsule pump with an overall pump volume of 424.7 μL. The new design results in a compact, simple, and inexpensive micropump and reduces the probability of contamination with attained almost zero dead volume values. The pump consists of NiTi-alloy SMA wires coiled on a flexible polymeric enclosure and actuated by joule heating. Unlike diaphragm and peristaltic SMA micropump designs that actuate transversely, our design is actuated longitudinally along the direction of the highest mechanical compliance resulting in large strokes in the order of 5.6 mm at 27% deflection ratio, actuation speed up to 11 mm/s, and static head pressures up to 14 kPa (105 mmHg) at 7.1 W input power; thus, high throughputs exceeding 2524 μL/min under free convention conditions could be achieved. A model was developed to optimize the pump’s geometrical parameters and the enclosure material. The model concluded that low stiffness enclosure material combined with thinner SMA wire diameter would result in the maximum deflection at the lowest power rating. To prove its viability for drug delivery applications, the pump was operated at a constant discharge volume at a relatively constant static head pressure. Furthermore, a design of bicuspid-inspired polymeric check-valves is presented and integrated onto the pump to regulate the flow. Since the built-in reservoir is replaceable, the pump capsule can be reused multiple times and for multiple drug types.
Collapse
|
17
|
A Peristaltic Micropump Based on the Fast Electrochemical Actuator: Design, Fabrication, and Preliminary Testing. ACTUATORS 2021. [DOI: 10.3390/act10030062] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
Microfluidic devices providing an accurate delivery of fluids at required rates are of considerable interest, especially for the biomedical field. The progress is limited by the lack of micropumps, which are compact, have high performance, and are compatible with standard microfabrication. This paper describes a micropump based on a new driving principle. The pump contains three membrane actuators operating peristaltically. The actuators are driven by nanobubbles of hydrogen and oxygen, which are generated in the chamber by a series of short voltage pulses of alternating polarity applied to the electrodes. This process guaranties the response time of the actuators to be much shorter than that of any other electrochemical device. The main part of the pump has a size of about 3 mm, which is an order of magnitude smaller in comparison with conventional micropumps. The pump is fabricated in glass and silicon wafers using standard cleanroom processes. The channels are formed in SU-8 photoresist and the membrane is made of SiNx. The channels are sealed by two processes of bonding between SU-8 and SiNx. Functionality of the channels and membranes is demonstrated. A defect of electrodes related to the lift-off fabrication procedure did not allow a demonstration of the pumping process although a flow rate of 1.5 µL/min and dosage accuracy of 0.25 nL are expected. The working characteristics of the pump make it attractive for the use in portable drug delivery systems, but the fabrication technology must be improved.
Collapse
|
18
|
Cai L, Gutruf P. Soft, Wireless and subdermally implantable recording and neuromodulation tools. J Neural Eng 2021; 18. [PMID: 33607646 DOI: 10.1088/1741-2552/abe805] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2020] [Accepted: 02/19/2021] [Indexed: 12/14/2022]
Abstract
Progress in understanding neuronal interaction and circuit behavior of the central and peripheral nervous system strongly relies on the advancement of tools that record and stimulate with high fidelity and specificity. Currently, devices used in exploratory research predominantly utilize cables or tethers to provide pathways for power supply, data communication, stimulus delivery and recording, which constrains the scope and use of such devices. In particular, the tethered connection, mechanical mismatch to surrounding soft tissues and bones frustrate the interface leading to irritation and limitation of motion of the subject, which in the case of fundamental and preclinical studies, impacts naturalistic behaviors of animals and precludes the use in experiments involving social interaction and ethologically relevant three-dimensional environments, limiting the use of current tools to mostly rodents and exclude species such as birds and fish. This review explores the current state-of-the-art in wireless, subdermally implantable tools that quantitively expand capabilities in analysis and perturbation of the central and peripheral nervous system by removing tethers and externalized features of implantable neuromodulation and recording tools. Specifically, the review explores power harvesting strategies, wireless communication schemes, and soft materials and mechanics that enable the creation of such devices and discuss their capabilities in the context of freely-behaving subjects. Highlights of this class of devices includes wireless battery-free and fully implantable operation with capabilities in cell specific recording, multimodal neural stimulation and electrical, optogenetic and pharmacological neuromodulation capabilities. We conclude with discussion on translation of such technologies which promises routes towards broad dissemination.
Collapse
Affiliation(s)
- Le Cai
- Biomedical Engineering, University of Arizona, 1230 N Cherry Ave., Tucson, Arizona, 85719, UNITED STATES
| | - Philipp Gutruf
- Biomedical Engineering, University of Arizona, 1230 N Cherry Ave., Tucson, Arizona, 85719, UNITED STATES
| |
Collapse
|
19
|
Intelligent automated drug administration and therapy: future of healthcare. Drug Deliv Transl Res 2021; 11:1878-1902. [PMID: 33447941 DOI: 10.1007/s13346-020-00876-4] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/09/2020] [Indexed: 12/13/2022]
Abstract
In the twenty-first century, the collaboration of control engineering and the healthcare sector has matured to some extent; however, the future will have promising opportunities, vast applications, and some challenges. Due to advancements in processing speed, the closed-loop administration of drugs has gained popularity for critically ill patients in intensive care units and routine life such as personalized drug delivery or implantable therapeutic devices. For developing a closed-loop drug delivery system, the control system works with a group of technologies like sensors, micromachining, wireless technologies, and pharmaceuticals. Recently, the integration of artificial intelligence techniques such as fuzzy logic, neural network, and reinforcement learning with the closed-loop drug delivery systems has brought their applications closer to fully intelligent automatic healthcare systems. This review's main objectives are to discuss the current developments, possibilities, and future visions in closed-loop drug delivery systems, for providing treatment to patients suffering from chronic diseases. It summarizes the present insight of closed-loop drug delivery/therapy for diabetes, gastrointestinal tract disease, cancer, anesthesia administration, cardiac ailments, and neurological disorders, from a perspective to show the research in the area of control theory.
Collapse
|
20
|
Villarruel Mendoza LA, Scilletta NA, Bellino MG, Desimone MF, Catalano PN. Recent Advances in Micro-Electro-Mechanical Devices for Controlled Drug Release Applications. Front Bioeng Biotechnol 2020; 8:827. [PMID: 32850709 PMCID: PMC7405504 DOI: 10.3389/fbioe.2020.00827] [Citation(s) in RCA: 27] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2020] [Accepted: 06/29/2020] [Indexed: 01/27/2023] Open
Abstract
In recent years, controlled release of drugs has posed numerous challenges with the aim of optimizing parameters such as the release of the suitable quantity of drugs in the right site at the right time with the least invasiveness and the greatest possible automation. Some of the factors that challenge conventional drug release include long-term treatments, narrow therapeutic windows, complex dosing schedules, combined therapies, individual dosing regimens, and labile active substance administration. In this sense, the emergence of micro-devices that combine mechanical and electrical components, so called micro-electro-mechanical systems (MEMS) can offer solutions to these drawbacks. These devices can be fabricated using biocompatible materials, with great uniformity and reproducibility, similar to integrated circuits. They can be aseptically manufactured and hermetically sealed, while having mobile components that enable physical or analytical functions together with electrical components. In this review we present recent advances in the generation of MEMS drug delivery devices, in which various micro and nanometric structures such as contacts, connections, channels, reservoirs, pumps, valves, needles, and/or membranes can be included in their design and manufacture. Implantable single and multiple reservoir-based and transdermal-based MEMS devices are discussed in terms of fundamental mechanisms, fabrication, performance, and drug release applications.
Collapse
Affiliation(s)
| | - Natalia Antonela Scilletta
- Departamento de Micro y Nanotecnologia, Instituto de Nanociencia y Nanotecnología, CNEA-CONICET, San Martín, Argentina
| | | | - Martin Federico Desimone
- Universidad de Buenos Aires, Consejo Nacional de Investigaciones Científicas y Técnicas (CONICET), Instituto de la Química y Metabolismo del Fármaco (IQUIMEFA), Facultad de Farmacia y Bioquímica, Buenos Aires, Argentina
| | - Paolo Nicolas Catalano
- Departamento de Micro y Nanotecnologia, Instituto de Nanociencia y Nanotecnología, CNEA-CONICET, San Martín, Argentina
- Universidad de Buenos Aires, Facultad de Farmacia y Bioquímica, Buenos Aires, Argentina
| |
Collapse
|
21
|
Forouzandeh F, Ahamed NN, Hsu MC, Walton JP, Frisina RD, Borkholder DA. A 3D-Printed Modular Microreservoir for Drug Delivery. MICROMACHINES 2020; 11:mi11070648. [PMID: 32629848 PMCID: PMC7407798 DOI: 10.3390/mi11070648] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/17/2020] [Revised: 06/23/2020] [Accepted: 06/27/2020] [Indexed: 11/16/2022]
Abstract
Reservoir-based drug delivery microsystems have enabled novel and effective drug delivery concepts in recent decades. These systems typically comprise integrated storing and pumping components. Here we present a stand-alone, modular, thin, scalable, and refillable microreservoir platform as a storing component of these microsystems for implantable and transdermal drug delivery. Three microreservoir capacities (1, 10, and 100 µL) were fabricated with 3 mm overall thickness using stereolithography 3D-printing technology, enabling the fabrication of the device structure comprising a storing area and a refill port. A thin, preformed dome-shaped storing membrane was created by the deposition of parylene-C over a polyethylene glycol sacrificial layer, creating a force-free membrane that causes zero forward flow and insignificant backward flow (2% of total volume) due to membrane force. A septum pre-compression concept was introduced that enabled the realization of a 1-mm-thick septa capable of ~65000 leak-free refill punctures under 100 kPa backpressure. The force-free storing membrane enables using normally-open micropumps for drug delivery, and potentially improves the efficiency and precision of normally-closed micropumps. The ultra-thin septum reduces the thickness of refillable drug delivery devices, and is capable of thousands of leak-free refills. This modular and scalable device can be used for drug delivery in different laboratory animals and humans, as a sampling device, and for lab-on-a-chip and point-of-care diagnostics applications.
Collapse
Affiliation(s)
- Farzad Forouzandeh
- Microsystems Engineering, Rochester Institute of Technology, Rochester, NY 14623, USA; (F.F.); (N.N.A.); (M.-C.H.)
| | - Nuzhet N. Ahamed
- Microsystems Engineering, Rochester Institute of Technology, Rochester, NY 14623, USA; (F.F.); (N.N.A.); (M.-C.H.)
| | - Meng-Chun Hsu
- Microsystems Engineering, Rochester Institute of Technology, Rochester, NY 14623, USA; (F.F.); (N.N.A.); (M.-C.H.)
| | - Joseph P. Walton
- Department of Chemical & Biomedical Engineering, Global Center for Hearing & Speech Research, University of South Florida, Tampa, FL 33612, USA; (J.P.W.); (R.D.F.)
- Department of Communication Sciences & Disorders, Global Center for Hearing & Speech Research, University of South Florida, Tampa, FL 33612, USA
| | - Robert D. Frisina
- Department of Chemical & Biomedical Engineering, Global Center for Hearing & Speech Research, University of South Florida, Tampa, FL 33612, USA; (J.P.W.); (R.D.F.)
- Department of Communication Sciences & Disorders, Global Center for Hearing & Speech Research, University of South Florida, Tampa, FL 33612, USA
- Department of Medical Engineering, Global Center for Hearing & Speech Research, University of South Florida, Tampa, FL 33612, USA
| | - David A. Borkholder
- Microsystems Engineering, Rochester Institute of Technology, Rochester, NY 14623, USA; (F.F.); (N.N.A.); (M.-C.H.)
- Correspondence: ; Tel.: +1-585-475-6067
| |
Collapse
|
22
|
Lee SH, Min SH, Cho YC, Han JH, Kim MN, Kim CR, Ahn CH, Kim BH, Lee C, Cho YM, Choy YB. Magnetically-driven implantable pump for on-demand bolus infusion of short-acting glucagon-like peptide-1 receptor agonist. J Control Release 2020; 325:111-120. [PMID: 32619744 DOI: 10.1016/j.jconrel.2020.06.022] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2020] [Revised: 06/12/2020] [Accepted: 06/21/2020] [Indexed: 10/24/2022]
Abstract
For type 2 diabetic patients, short acting glucagon-like peptide-1 receptor agonist (GLP-1 RA) is often prescribed with frequent needled injections. Long-acting GLP-1 RA for less frequent injections do not mimic physiologic secretion of GLP-1. Therefore, an implantable pump is proposed in this work, which can deliver a short-acting GLP-1 RA, exenatide, without needles and batteries. The implanted pump can infuse an accurate amount of exenatide bolus only when a noninvasive magnetic force is applied from outside the body. The pump includes a safety feature of patterned magnets for actuation to prevent accidental infusion possibly caused by a general household magnet. The reservoir for exenatide is made of a flexible biomaterial and thus, a negative pressure build-up in the reservoir can be prevented even after multiple actuations and almost all drug consumption (~ 94%). This allows a reproducible drug dose for a longer period after implantation, hence less frequent replenishment procedures. The pump is also equipped with an intermediate container with two distinct check-valves and thus, the reservoir of exenatide can be further separated and better prevented from infiltration of the bodily fluid surrounding the implanted pump. When tested in Goto-Kakizaki rats, the pump demonstrates the efficacy of exenatide similar to conventional subcutaneous injections. Therefore, the pump can be promising for patient-friendly, optimal delivery of short-acting GLP-1 RA that better follows the physiologic secretion profile of GLP-1.
Collapse
Affiliation(s)
- Seung Ho Lee
- Institute of Medical and Biological Engineering, Medical Research Center, Seoul National University, Seoul 03080, Republic of Korea
| | - Se Hee Min
- Department of Internal Medicine, Seoul National University College of Medicine, Seoul 03080, Republic of Korea; Department of Translational Medicine, Seoul National University College of Medicine, Seoul 03080, Republic of Korea
| | - Yong Chan Cho
- Interdisciplinary Program in Bioengineering, College of Engineering, Seoul National University, Seoul 08826, Republic of Korea
| | - Jae Hoon Han
- Interdisciplinary Program in Bioengineering, College of Engineering, Seoul National University, Seoul 08826, Republic of Korea
| | - Mi Na Kim
- Department of Translational Medicine, Seoul National University College of Medicine, Seoul 03080, Republic of Korea
| | - Cho Rim Kim
- Interdisciplinary Program in Bioengineering, College of Engineering, Seoul National University, Seoul 08826, Republic of Korea
| | - Chang Ho Ahn
- Department of Internal Medicine, Seoul National University College of Medicine, Seoul 03080, Republic of Korea; Department of Translational Medicine, Seoul National University College of Medicine, Seoul 03080, Republic of Korea
| | - Byung Hwi Kim
- Department of Biomedical Engineering, Seoul National University College of Medicine, Seoul 03080, Republic of Korea
| | - Cheol Lee
- Department of Pathology, Seoul National University College of Medicine, Seoul 03080, Republic of Korea
| | - Young Min Cho
- Department of Internal Medicine, Seoul National University College of Medicine, Seoul 03080, Republic of Korea; Department of Translational Medicine, Seoul National University College of Medicine, Seoul 03080, Republic of Korea.
| | - Young Bin Choy
- Institute of Medical and Biological Engineering, Medical Research Center, Seoul National University, Seoul 03080, Republic of Korea; Interdisciplinary Program in Bioengineering, College of Engineering, Seoul National University, Seoul 08826, Republic of Korea; Department of Biomedical Engineering, Seoul National University College of Medicine, Seoul 03080, Republic of Korea.
| |
Collapse
|
23
|
Abstract
With ever-increasing concerns on health and environmental safety, there is a fast-growing interest in new technologies for medical devices and applications. Particularly, wireless power transfer (WPT) technology provides reliable and convenient power charging for implant medical devices without additional surgery. For those WPT medical systems, the width of the human body restricts the charging distance, while the specific absorption rate (SAR) standard limits the intensity of the electromagnetic field. In order to develop a high-efficient charging strategy for medical implants, the key factors of transmission distance, coil structure, resonant frequency, etc. are paid special attention. In this paper, a comprehensive overview of near-field WPT technologies in medical devices is presented and discussed. Also, future development is discussed for the prediction of different devices when embedded in various locations of the human body. Moreover, the key issues including power transfer efficiency and output power are addressed and analyzed. All concerning characteristics of WPT links for medical usage are elaborated and discussed. Thus, this review provides an in-depth investigation and the whole map for WPT technologies applied in medical applications.
Collapse
|
24
|
He L, Zhao D, Li W, Xu Q, Cheng G. Performance analysis of valveless piezoelectric pump with dome composite structures. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2019; 90:065002. [PMID: 31255023 DOI: 10.1063/1.5084307] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/06/2018] [Accepted: 05/30/2019] [Indexed: 06/09/2023]
Abstract
Valveless piezoelectric pumps are used in the field of drug delivery. However, the output performances are limited by severe reflux. This article is aimed at reducing the reflux and improving the output performances. We use different pressure loss coefficients in the forward and reverse directions and design dome composite structures within the chamber of the valveless pump. The structures and working principles are described. Then, we use the fluid simulation software CFX to simulate the flow state inside the chamber under different parameters such as the dome length, 2 mm, 4 mm, 6 mm, and 8 mm; the trapezoidal one-sided angle, 1°, 3°, 5°, 7°, and 9°; and the rounded corner, from 0 to 6 mm. Finally, we also make the prototypes and test the output performances. The results show that the output flow rate can reach a maximum of 220.6 ml/min; the measured variance is 80.7 in the three experiment tests for the optimal flow rate at the dome length of 8 mm, angle of 5°, and rounded corner of 6 mm under the driving voltage of 190 V at a frequency of 45 Hz; the highest output pressure is 670.0 Pa under the voltage of 190 V at a frequency of 130 Hz. Moreover, the precision is 5.85% of the highest tested pressure compared to the simulated pressure. The output flow rate has a great improvement, and the effectiveness of the structures is proved.
Collapse
Affiliation(s)
- Lipeng He
- College of Mechanical and Electrical Engineering, Changchun University of Technology, Changchun 130012, China
| | - Da Zhao
- College of Mechanical and Electrical Engineering, Changchun University of Technology, Changchun 130012, China
| | - Wei Li
- College of Mechanical and Electrical Engineering, Changchun University of Technology, Changchun 130012, China
| | - Quanwen Xu
- College of Mechanical and Electrical Engineering, Changchun University of Technology, Changchun 130012, China
| | - Guangming Cheng
- Institute of Precision Machinery, Zhejiang Normal University, Jinhua 321004, China
| |
Collapse
|
25
|
Lee SH, Kim BH, Park CG, Lee C, Lim BY, Choy YB. Implantable small device enabled with magnetic actuation for on-demand and pulsatile drug delivery. J Control Release 2018; 286:224-230. [DOI: 10.1016/j.jconrel.2018.07.037] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2018] [Revised: 07/17/2018] [Accepted: 07/23/2018] [Indexed: 11/25/2022]
|
26
|
Lee HJ, Choi N, Yoon ES, Cho IJ. MEMS devices for drug delivery. Adv Drug Deliv Rev 2018; 128:132-147. [PMID: 29117510 DOI: 10.1016/j.addr.2017.11.003] [Citation(s) in RCA: 46] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2017] [Revised: 09/06/2017] [Accepted: 11/02/2017] [Indexed: 01/27/2023]
Abstract
Novel drug delivery systems based on microtechnology have advanced tremendously, but yet face some technological and societal hurdles to fully achieve their potential. The novel drug delivery systems aim to deliver drugs in a spatiotemporal- and dosage-controlled manner with a goal to address the unmet medical needs from oral delivery and hypodermic injection. The unmet needs include effective delivery of new types of drug candidates that are otherwise insoluble and unstable, targeted delivery to areas protected by barriers (e.g. brain and posterior eye segment), localized delivery of potent drugs, and improved patient compliance. After scrutinizing the design considerations and challenges associated with delivery to areas that cannot be efficiently targeted through standard drug delivery (e.g. brain, posterior eye segment, and gastrointestinal tract), this review provides a summary of recent advances that addressed these challenges and summarizes yet unresolved problems in each target area. The opportunities for innovation in devising the novel drug delivery systems are still high; with integration of advanced microtechnology, advanced fabrication of biomaterials, and biotechnology, the novel drug delivery is poised to be a promising alternative to the oral administration and hypodermic injection for a large spectrum of drug candidates.
Collapse
Affiliation(s)
- Hyunjoo J Lee
- School of Electrical Engineering, Korea Advanced Institute of Science and Technology, Daejeon 34141, Republic of Korea
| | - Nakwon Choi
- Center for BioMicrosystems, Brain Science Institute, Korea Institute of Science and Technology (KIST), Seoul 02792, Republic of Korea; Division of Bio-Medical Science & Technology (Biomedical Engineering), KIST School, Korea University of Science and Technology (UST), Daejeon 34113, Republic of Korea
| | - Eui-Sung Yoon
- Center for BioMicrosystems, Brain Science Institute, Korea Institute of Science and Technology (KIST), Seoul 02792, Republic of Korea
| | - Il-Joo Cho
- Center for BioMicrosystems, Brain Science Institute, Korea Institute of Science and Technology (KIST), Seoul 02792, Republic of Korea; Division of Bio-Medical Science & Technology (Biomedical Engineering), KIST School, Korea University of Science and Technology (UST), Daejeon 34113, Republic of Korea.
| |
Collapse
|
27
|
Adams SD, Kouzani AZ, Tye SJ, Bennet KE, Berk M. An investigation into closed-loop treatment of neurological disorders based on sensing mitochondrial dysfunction. J Neuroeng Rehabil 2018; 15:8. [PMID: 29439744 PMCID: PMC5811973 DOI: 10.1186/s12984-018-0349-z] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2017] [Accepted: 02/05/2018] [Indexed: 12/14/2022] Open
Abstract
Dynamic feedback based closed-loop medical devices offer a number of advantages for treatment of heterogeneous neurological conditions. Closed-loop devices integrate a level of neurobiological feedback, which allows for real-time adjustments to be made with the overarching aim of improving treatment efficacy and minimizing risks for adverse events. One target which has not been extensively explored as a potential feedback component in closed-loop therapies is mitochondrial function. Several neurodegenerative and psychiatric disorders including Parkinson's disease, Major Depressive disorder and Bipolar disorder have been linked to perturbations in the mitochondrial respiratory chain. This paper investigates the potential to monitor this mitochondrial function as a method of feedback for closed-loop neuromodulation treatments. A generic model of the closed-loop treatment is developed to describe the high-level functions of any system designed to control neural function based on mitochondrial response to stimulation, simplifying comparison and future meta-analysis. This model has four key functional components including: a sensor, signal manipulator, controller and effector. Each of these components are described and several potential technologies for each are investigated. While some of these candidate technologies are quite mature, there are still technological gaps remaining. The field of closed-loop medical devices is rapidly evolving, and whilst there is a lot of interest in this area, widespread adoption has not yet been achieved due to several remaining technological hurdles. However, the significant therapeutic benefits offered by this technology mean that this will be an active area for research for years to come.
Collapse
Affiliation(s)
- Scott D. Adams
- School of Engineering, Deakin University, Geelong, VIC 3216 Australia
| | - Abbas Z. Kouzani
- School of Engineering, Deakin University, Geelong, VIC 3216 Australia
| | - Susannah J. Tye
- Department of Psychiatry and Psychology, Mayo Clinic, Rochester, MN 55905 USA
| | - Kevin E. Bennet
- Division of Engineering, Mayo Clinic, Rochester, MN 55905 USA
| | - Michael Berk
- School of Medicine, Deakin University, Waurn Ponds, VIC 3216 Australia
| |
Collapse
|
28
|
Kumar V, Kumar V, McGuire T, Coulter DW, Sharp JG, Mahato RI. Challenges and Recent Advances in Medulloblastoma Therapy. Trends Pharmacol Sci 2017; 38:1061-1084. [PMID: 29061299 DOI: 10.1016/j.tips.2017.09.002] [Citation(s) in RCA: 52] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2017] [Revised: 09/19/2017] [Accepted: 09/25/2017] [Indexed: 10/18/2022]
Abstract
Medulloblastoma (MB) is the most common childhood brain tumor, which occurs in the posterior fossa. MB tumors are highly heterogeneous and have diverse genetic make-ups, with differential microRNA (miRNA) expression profiles and variable prognoses. MB can be classified into four subgroups, each with different origins, pathogenesis, and potential therapeutic targets. miRNA and small-molecule targeted therapies have emerged as a potential new therapeutic paradigm in MB treatment. However, the development of chemoresistance due to surviving cancer stem cells and dysregulation of miRNAs remains a challenge. Combination therapies using multiple drugs and miRNAs could be effective approaches. In this review we discuss various MB subtypes, barriers, and novel therapeutic options which may be less toxic than current standard treatments.
Collapse
Affiliation(s)
- Vinod Kumar
- Department of Pharmaceutical Sciences, University of Nebraska Medical Center, Omaha, NE 68198, USA
| | - Virender Kumar
- Department of Pharmaceutical Sciences, University of Nebraska Medical Center, Omaha, NE 68198, USA
| | - Timothy McGuire
- Department of Pharmacy Practice, University of Nebraska Medical Center, Omaha, NE 68198, USA
| | - Donald W Coulter
- Department of Pediatrics, University of Nebraska Medical Center, Omaha, NE 68198, USA
| | - John G Sharp
- Department of Genetics, Cell Biology, and Anatomy, University of Nebraska Medical Center, Omaha, NE 68198, USA
| | - Ram I Mahato
- Department of Pharmaceutical Sciences, University of Nebraska Medical Center, Omaha, NE 68198, USA.
| |
Collapse
|
29
|
Sim JY, Haney MP, Park SI, McCall JG, Jeong JW. Microfluidic neural probes: in vivo tools for advancing neuroscience. LAB ON A CHIP 2017; 17:1406-1435. [PMID: 28349140 DOI: 10.1039/c7lc00103g] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/09/2023]
Abstract
Microfluidic neural probes hold immense potential as in vivo tools for dissecting neural circuit function in complex nervous systems. Miniaturization, integration, and automation of drug delivery tools open up new opportunities for minimally invasive implants. These developments provide unprecedented spatiotemporal resolution in fluid delivery as well as multifunctional interrogation of neural activity using combined electrical and optical modalities. Capitalizing on these unique features, microfluidic technology will greatly advance in vivo pharmacology, electrophysiology, optogenetics, and optopharmacology. In this review, we discuss recent advances in microfluidic neural probe systems. In particular, we will highlight the materials and manufacturing processes of microfluidic probes, device configurations, peripheral devices for fluid handling and packaging, and wireless technologies that can be integrated for the control of these microfluidic probe systems. This article summarizes various microfluidic implants and discusses grand challenges and future directions for further developments.
Collapse
Affiliation(s)
- Joo Yong Sim
- Electronics and Telecommunications Research Institute, Bio-Medical IT Convergence Research Department, Daejeon, 34129, Republic of Korea
| | | | | | | | | |
Collapse
|
30
|
Song P, Kuang S, Panwar N, Yang G, Tng DJH, Tjin SC, Ng WJ, Majid MBA, Zhu G, Yong KT, Wang ZL. A Self-Powered Implantable Drug-Delivery System Using Biokinetic Energy. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2017; 29:1605668. [PMID: 28067957 DOI: 10.1002/adma.201605668] [Citation(s) in RCA: 59] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/20/2016] [Revised: 11/13/2016] [Indexed: 05/21/2023]
Abstract
The first triboelectric-nanogenerator (TENG)-based self-powered implantable drug-delivery system is presented. Pumping flow rates from 5.3 to 40 µL min-1 under different rotating speeds of the TENG are realized. The implantable drug-delivery system can be powered with a TENG device rotated by human hand motion. Ex vivo trans-sclera drug delivery in porcine eyes is demonstrated by utilizing the biokinetic energies of human hands.
Collapse
Affiliation(s)
- Peiyi Song
- Nanyang Environment and Water Research Institute, Nanyang Technological University, 1 Cleantech Loop, CleanTech One #06-08, Singapore, 637141, Singapore
- School of Electrical and Electronic Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore, 639798, Singapore
| | - Shuangyang Kuang
- Beijing Institute of Nanoenergy and Nanosystems, Chinese Academy of Sciences, Beijing, 100083, China
| | - Nishtha Panwar
- School of Electrical and Electronic Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore, 639798, Singapore
| | - Guang Yang
- School of Electrical and Electronic Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore, 639798, Singapore
| | | | - Swee Chuan Tjin
- Nanyang Environment and Water Research Institute, Nanyang Technological University, 1 Cleantech Loop, CleanTech One #06-08, Singapore, 637141, Singapore
- School of Electrical and Electronic Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore, 639798, Singapore
| | - Wun Jern Ng
- Nanyang Environment and Water Research Institute, Nanyang Technological University, 1 Cleantech Loop, CleanTech One #06-08, Singapore, 637141, Singapore
| | - Maszenan Bin Abdul Majid
- Nanyang Environment and Water Research Institute, Nanyang Technological University, 1 Cleantech Loop, CleanTech One #06-08, Singapore, 637141, Singapore
| | - Guang Zhu
- Beijing Institute of Nanoenergy and Nanosystems, Chinese Academy of Sciences, Beijing, 100083, China
| | - Ken-Tye Yong
- Nanyang Environment and Water Research Institute, Nanyang Technological University, 1 Cleantech Loop, CleanTech One #06-08, Singapore, 637141, Singapore
- School of Electrical and Electronic Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore, 639798, Singapore
| | - Zhong Lin Wang
- Beijing Institute of Nanoenergy and Nanosystems, Chinese Academy of Sciences, Beijing, 100083, China
- School of Material Science and Engineering, Georgia Institute of Technology, Atlanta, GA, 30332-0245, USA
| |
Collapse
|
31
|
Sheybani R, Cobo A, Meng E. Wireless programmable electrochemical drug delivery micropump with fully integrated electrochemical dosing sensors. Biomed Microdevices 2016; 17:74. [PMID: 26149696 DOI: 10.1007/s10544-015-9980-7] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
We present a fully integrated implantable electrolysis-based micropump with incorporated EI dosing sensors. Wireless powering and data telemetry (through amplitude and frequency modulation) were utilized to achieve variable flow control and a bi-directional data link with the sensors. Wireless infusion rate control (0.14-1.04 μL/min) and dose sensing (bolus resolution of 0.55-2 μL) were each calibrated separately with the final circuit architecture and then simultaneous wireless flow control and dose sensing were demonstrated. Recombination detection using the dosing system, as well as, effects of coil separation distance and misalignment in wireless power and data transfer were studied. A custom-made normally closed spring-loaded ball check valve was designed and incorporated at the reservoir outlet to prevent backflow of fluids as a result of the reverse pressure gradient caused by recombination of electrolysis gases. Successful delivery, infusion rate control, and dose sensing were achieved in simulated brain tissue.
Collapse
Affiliation(s)
- Roya Sheybani
- Department of Biomedical Engineering, Viterbi School of Engineering, University of Southern California, 1042 Downey Way, DRB-140, Los Angeles, CA, 90089-1111, USA
| | | | | |
Collapse
|