1
|
Pokhvishcheva NV, Prozherin IS, Kalinichev AV, Peshkova MA. Response Patterns of Chromoionophore-Based Bulk Optodes Containing Lipophilic Electrolytes: Toward Background-Independent pH-Sensing. ACS Sens 2023; 8:3086-3094. [PMID: 37524060 DOI: 10.1021/acssensors.3c00742] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/02/2023]
Abstract
Despite a number of advantages of ion-selective optical sensors (optodes), their practical application is limited by their response mechanism, which leads to the dependence of the signal on the activity of two ions (analyte ion and the so-called reference ion) in the solution at the same time. Here, we show that the introduction of a lipophilic electrolyte into the polymeric optode membrane allows assessing the ionic activity of H+ cations regardless of the concentration of the background electrolyte containing a hydrophilic cation, with NaCl as an example of such an electrolyte. For the first time, the applicability of this approach is proven theoretically utilizing the numerical simulation of optode response. A correlation between the interfacial potential stability and the single-ion optical response is established. The predicted optical response is independent of background cation concentration to a significant extent. Theoretical conclusions are supported by experimental data obtained with chromoionophore-based optodes doped with various lipophilic electrolytes, including ionic liquids, by thin-film spectrophotometry and macrophotography coupled with digital color analysis. Most of the experimental sensor characteristics, such as the response range and its median, as well as its independence from the background electrolyte concentration are in quantitative agreement with the proposed theoretical description.
Collapse
Affiliation(s)
- Nadezhda V Pokhvishcheva
- Institute of Chemistry, Saint Petersburg State University, 7/9 Universitetskaya Emb., 199034 St. Petersburg, Russia
| | - Ilya S Prozherin
- Institute of Chemistry, Saint Petersburg State University, 7/9 Universitetskaya Emb., 199034 St. Petersburg, Russia
| | - Andrey V Kalinichev
- Institute of Chemistry, Saint Petersburg State University, 7/9 Universitetskaya Emb., 199034 St. Petersburg, Russia
| | - Maria A Peshkova
- Institute of Chemistry, Saint Petersburg State University, 7/9 Universitetskaya Emb., 199034 St. Petersburg, Russia
| |
Collapse
|
2
|
Ibrahim NFA, Sabani N, Johari S, Manaf AA, Wahab AA, Zakaria Z, Noor AM. A Comprehensive Review of the Recent Developments in Wearable Sweat-Sensing Devices. SENSORS (BASEL, SWITZERLAND) 2022; 22:7670. [PMID: 36236769 PMCID: PMC9573257 DOI: 10.3390/s22197670] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/23/2022] [Revised: 09/26/2022] [Accepted: 10/02/2022] [Indexed: 06/16/2023]
Abstract
Sweat analysis offers non-invasive real-time on-body measurement for wearable sensors. However, there are still gaps in current developed sweat-sensing devices (SSDs) regarding the concerns of mixing fresh and old sweat and real-time measurement, which are the requirements to ensure accurate the measurement of wearable devices. This review paper discusses these limitations by aiding model designs, features, performance, and the device operation for exploring the SSDs used in different sweat collection tools, focusing on continuous and non-continuous flow sweat analysis. In addition, the paper also comprehensively presents various sweat biomarkers that have been explored by earlier works in order to broaden the use of non-invasive sweat samples in healthcare and related applications. This work also discusses the target analyte's response mechanism for different sweat compositions, categories of sweat collection devices, and recent advances in SSDs regarding optimal design, functionality, and performance.
Collapse
Affiliation(s)
- Nur Fatin Adini Ibrahim
- Faculty of Electronic Engineering & Technology, Universiti Malaysia Perlis, Arau 02600, Malaysia
| | - Norhayati Sabani
- Faculty of Electronic Engineering & Technology, Universiti Malaysia Perlis, Arau 02600, Malaysia
- Center of Excellance Micro System Technology, Universiti Malaysia Perlis, Arau 02600, Malaysia
| | - Shazlina Johari
- Faculty of Electronic Engineering & Technology, Universiti Malaysia Perlis, Arau 02600, Malaysia
- Center of Excellance Micro System Technology, Universiti Malaysia Perlis, Arau 02600, Malaysia
| | - Asrulnizam Abd Manaf
- Collaborative Microelectronic Design Excellence Centre, Universiti Sains Malaysia, Gelugor 11800, Malaysia
| | - Asnida Abdul Wahab
- Department of Biomedical Engineering and Health Sciences, Universiti Teknologi Malaysia, Johor Bahru 81310, Malaysia
| | - Zulkarnay Zakaria
- Faculty of Electronic Engineering & Technology, Universiti Malaysia Perlis, Arau 02600, Malaysia
- Sports Engineering Research Center, Universiti Malaysia Perlis, Arau 02600, Malaysia
| | - Anas Mohd Noor
- Faculty of Electronic Engineering & Technology, Universiti Malaysia Perlis, Arau 02600, Malaysia
- Center of Excellance Micro System Technology, Universiti Malaysia Perlis, Arau 02600, Malaysia
| |
Collapse
|
3
|
Saez J, Catalan-Carrio R, Owens RM, Basabe-Desmonts L, Benito-Lopez F. Microfluidics and materials for smart water monitoring: A review. Anal Chim Acta 2021; 1186:338392. [PMID: 34756264 DOI: 10.1016/j.aca.2021.338392] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2020] [Revised: 03/02/2021] [Accepted: 03/02/2021] [Indexed: 01/03/2023]
Abstract
Water quality monitoring of drinking, waste, fresh and seawaters is of great importance to ensure safety and wellbeing for humans, fauna and flora. Researchers are developing robust water monitoring microfluidic devices but, the delivery of a cost-effective, commercially available platform has not yet been achieved. Conventional water monitoring is mainly based on laboratory instruments or sophisticated and expensive handheld probes for on-site analysis, both requiring trained personnel and being time-consuming. As an alternative, microfluidics has emerged as a powerful tool with the capacity to replace conventional analytical systems. Nevertheless, microfluidic devices largely use conventional pumps and valves for operation and electronics for sensing, that increment the dimensions and cost of the final platforms, reducing their commercialization perspectives. In this review, we critically analyze the characteristics of conventional microfluidic devices for water monitoring, focusing on different water sources (drinking, waste, fresh and seawaters), and their application in commercial products. Moreover, we introduce the revolutionary concept of using functional materials such as hydrogels, poly(ionic liquid) hydrogels and ionogels as alternatives to conventional fluidic handling and sensing tools, for water monitoring in microfluidic devices.
Collapse
Affiliation(s)
- Janire Saez
- Microfluidics Cluster UPV/EHU, Analytical Microsystems & Materials for Lab-on-a-Chip (AMMa-LOAC), Group, Analytical Chemistry, University of the Basque Country UPV/EHU, Spain; Bioelectronic Systems Technology Group, Department of Chemical Engineering and Biotechnology, Philippa Fawcett Drive, Cambridge, CB3 0AS, UK.
| | - Raquel Catalan-Carrio
- Microfluidics Cluster UPV/EHU, Analytical Microsystems & Materials for Lab-on-a-Chip (AMMa-LOAC), Group, Analytical Chemistry, University of the Basque Country UPV/EHU, Spain; Microfluidics Cluster UPV/EHU, BIOMICs Microfluidics Group, Lascaray Research Center, University of the Basque Country UPV/EHU, Vitoria-Gasteiz, Spain
| | - Róisín M Owens
- Bioelectronic Systems Technology Group, Department of Chemical Engineering and Biotechnology, Philippa Fawcett Drive, Cambridge, CB3 0AS, UK
| | - Lourdes Basabe-Desmonts
- Microfluidics Cluster UPV/EHU, BIOMICs Microfluidics Group, Lascaray Research Center, University of the Basque Country UPV/EHU, Vitoria-Gasteiz, Spain; Basque Foundation for Science, IKERBASQUE, Spain; Bioaraba Health Research Institute, Microfluidics Cluster UPV/EHU, Vitoria-Gasteiz, Spain; BCMaterials, Basque Center for Materials, Applications and Nanostructures, UPV/EHU Science Park, 48940, Leioa, Spain.
| | - Fernando Benito-Lopez
- Microfluidics Cluster UPV/EHU, Analytical Microsystems & Materials for Lab-on-a-Chip (AMMa-LOAC), Group, Analytical Chemistry, University of the Basque Country UPV/EHU, Spain; Bioaraba Health Research Institute, Microfluidics Cluster UPV/EHU, Vitoria-Gasteiz, Spain; BCMaterials, Basque Center for Materials, Applications and Nanostructures, UPV/EHU Science Park, 48940, Leioa, Spain.
| |
Collapse
|
4
|
Bartoszewicz B, Lewenstam A, Migdalski J. Solid-Contact Electrode with Composite PVC-Based 3D-Printed Membrane. Optimization of Fabrication and Performance. SENSORS 2021; 21:s21144909. [PMID: 34300652 PMCID: PMC8309799 DOI: 10.3390/s21144909] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/21/2021] [Revised: 07/15/2021] [Accepted: 07/16/2021] [Indexed: 11/16/2022]
Abstract
Intense interest in reference electrode design and fabrication has recently been enriched with the application of 3D printing of electrodes with salt-loaded PVC membranes. This type of material is attractive in sensor technology and is challenging to implement in 3D. In this report, several improvements and simplifications in the technology were focused on and supported by a fundamental electrochemical characterization.
Collapse
|
5
|
Rousseau CR, Bühlmann P. Calibration-free potentiometric sensing with solid-contact ion-selective electrodes. Trends Analyt Chem 2021. [DOI: 10.1016/j.trac.2021.116277] [Citation(s) in RCA: 25] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
|
6
|
Lenar N, Piech R, Paczosa-Bator B. Potentiometric Sensor with High Capacity Composite Composed of Ruthenium Dioxide and Poly(3,4-ethylenedioxythiophene) Polystyrene Sulfonate. MATERIALS (BASEL, SWITZERLAND) 2021; 14:1891. [PMID: 33920197 PMCID: PMC8069098 DOI: 10.3390/ma14081891] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/09/2021] [Revised: 04/01/2021] [Accepted: 04/07/2021] [Indexed: 12/15/2022]
Abstract
This work presents the first-time application of the ruthenium dioxide-poly(3,4-ethylenedioxythiophene) polystyrene sulfonate high-capacity composite material as a mediation layer in potassium selective electrodes, which turned out to significantly enhance the electrical and analytical parameters of the electrodes. The idea was to combine the properties of two different types of materials: a conducting polymer, poly(3,4-ethylenedioxythiophene) polystyrene sulfonate, and a metal oxide, ruthenium dioxide, in order to obtain the material for a solid-contact layer of great electrical and physicochemical parameters. The preparation method for composite material proposed in this work is fast and easy. The mediation layer material was examined using a scanning electron microscope and chronopotentiometry in order to confirm that all requirements for mediation layers materials were fulfilled. Ruthenium dioxide-poly(3,4-ethylenedioxythiophene) polystyrene sulfonate nancomposite material turned out to exhibit remarkably high electrical capacitance (of approximately 17.5 mF), which ensured great performance of designed K+-selective sensors. Electrodes of electrical capacity equal to 7.2 mF turned out to exhibit fast and stable (with only 0.077 mV potential change per hour) potentiometric responses in the wide range of potassium ion concentrations (10-6 M to 10-1 M). The electrical capacity of ruthenium dioxide-poly(3,4-ethylenedioxythiophene) polystyrene sulfonate-contacted electrodes characterized by electrical capacitance parameters was the highest reported so far for this type of sensor.
Collapse
Affiliation(s)
| | | | - Beata Paczosa-Bator
- Faculty of Materials Science and Ceramics, AGH University of Science and Technology, Mickiewicza 30, 30059 Krakow, Poland; (N.L.); (R.P.)
| |
Collapse
|
7
|
Shitanda I, Miyazaki K, Loew N, Esaka R, Hoshi Y, Itagaki M. A screen-printed three-electrode-type sticker device with an accurate liquid junction-type reference electrode. Chem Commun (Camb) 2021; 57:2875-2878. [PMID: 33656029 DOI: 10.1039/d1cc00850a] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
We developed a novel sticker device that can convert any metal or alloy into the working electrode of a three-electrode system, enabling simple and accurate measurement. The sticker, containing a counter electrode and a stable and accurate liquid junction-type reference electrode, is attached to the metal or alloy; meanwhile the surface exposed from a hole in the device functions as the working electrode. This sticker device was fabricated by screen-printing. The polarization curve of the copper and tin-plated copper measured using the sticker device exhibited approximately the same behavior as that obtained for the conventional three-electrode system. The characteristics of various materials can be easily evaluated using this system by only dropping a small amount of solution.
Collapse
Affiliation(s)
- Isao Shitanda
- Department of Pure and Applied Chemistry, Faculty of Science and Technology, Tokyo University of Science, 2641 Yamazaki, Noda, Chiba 278-8510, Japan. and Research Institute for Science and Technology, Tokyo University of Science, 2641 Yamazaki, Noda, Chiba 278-8510, Japan
| | - Kaishi Miyazaki
- Department of Pure and Applied Chemistry, Faculty of Science and Technology, Tokyo University of Science, 2641 Yamazaki, Noda, Chiba 278-8510, Japan.
| | - Noya Loew
- Department of Pure and Applied Chemistry, Faculty of Science and Technology, Tokyo University of Science, 2641 Yamazaki, Noda, Chiba 278-8510, Japan.
| | - Ryosuke Esaka
- Department of Pure and Applied Chemistry, Faculty of Science and Technology, Tokyo University of Science, 2641 Yamazaki, Noda, Chiba 278-8510, Japan.
| | - Yoshinao Hoshi
- Department of Pure and Applied Chemistry, Faculty of Science and Technology, Tokyo University of Science, 2641 Yamazaki, Noda, Chiba 278-8510, Japan.
| | - Masayuki Itagaki
- Department of Pure and Applied Chemistry, Faculty of Science and Technology, Tokyo University of Science, 2641 Yamazaki, Noda, Chiba 278-8510, Japan. and Research Institute for Science and Technology, Tokyo University of Science, 2641 Yamazaki, Noda, Chiba 278-8510, Japan
| |
Collapse
|
8
|
Lyu Y, Gan S, Bao Y, Zhong L, Xu J, Wang W, Liu Z, Ma Y, Yang G, Niu L. Solid-Contact Ion-Selective Electrodes: Response Mechanisms, Transducer Materials and Wearable Sensors. MEMBRANES 2020; 10:membranes10060128. [PMID: 32585903 PMCID: PMC7345918 DOI: 10.3390/membranes10060128] [Citation(s) in RCA: 48] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/28/2020] [Revised: 06/15/2020] [Accepted: 06/16/2020] [Indexed: 12/14/2022]
Abstract
Wearable sensors based on solid-contact ion-selective electrodes (SC-ISEs) are currently attracting intensive attention in monitoring human health conditions through real-time and non-invasive analysis of ions in biological fluids. SC-ISEs have gone through a revolution with improvements in potential stability and reproducibility. The introduction of new transducing materials, the understanding of theoretical potentiometric responses, and wearable applications greatly facilitate SC-ISEs. We review recent advances in SC-ISEs including the response mechanism (redox capacitance and electric-double-layer capacitance mechanisms) and crucial solid transducer materials (conducting polymers, carbon and other nanomaterials) and applications in wearable sensors. At the end of the review we illustrate the existing challenges and prospects for future SC-ISEs. We expect this review to provide readers with a general picture of SC-ISEs and appeal to further establishing protocols for evaluating SC-ISEs and accelerating commercial wearable sensors for clinical diagnosis and family practice.
Collapse
Affiliation(s)
- Yan Lyu
- School of Civil Engineering, c/o Center for Advanced Analytical Science, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou 510006, China; (Y.L.); (Y.B.); (L.Z.); (W.W.); (Z.L.); (Y.M.)
| | - Shiyu Gan
- School of Civil Engineering, c/o Center for Advanced Analytical Science, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou 510006, China; (Y.L.); (Y.B.); (L.Z.); (W.W.); (Z.L.); (Y.M.)
- Correspondence: (S.G.); (L.N.)
| | - Yu Bao
- School of Civil Engineering, c/o Center for Advanced Analytical Science, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou 510006, China; (Y.L.); (Y.B.); (L.Z.); (W.W.); (Z.L.); (Y.M.)
| | - Lijie Zhong
- School of Civil Engineering, c/o Center for Advanced Analytical Science, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou 510006, China; (Y.L.); (Y.B.); (L.Z.); (W.W.); (Z.L.); (Y.M.)
| | - Jianan Xu
- State Key Laboratory of Electroanalytical Chemistry, c/o Engineering Laboratory for Modern Analytical Techniques, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun 130022, China;
- University of Chinese Academy of Sciences, Beijing 100039, China
| | - Wei Wang
- School of Civil Engineering, c/o Center for Advanced Analytical Science, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou 510006, China; (Y.L.); (Y.B.); (L.Z.); (W.W.); (Z.L.); (Y.M.)
| | - Zhenbang Liu
- School of Civil Engineering, c/o Center for Advanced Analytical Science, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou 510006, China; (Y.L.); (Y.B.); (L.Z.); (W.W.); (Z.L.); (Y.M.)
| | - Yingming Ma
- School of Civil Engineering, c/o Center for Advanced Analytical Science, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou 510006, China; (Y.L.); (Y.B.); (L.Z.); (W.W.); (Z.L.); (Y.M.)
| | - Guifu Yang
- School of Information Science and Technology, Northeast Normal University, Changchun 130117, China;
| | - Li Niu
- School of Civil Engineering, c/o Center for Advanced Analytical Science, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou 510006, China; (Y.L.); (Y.B.); (L.Z.); (W.W.); (Z.L.); (Y.M.)
- MOE Key Laboratory for Water Quality and Conservation of the Pearl River Delta, Guangzhou University, Guangzhou 510006, China
- Correspondence: (S.G.); (L.N.)
| |
Collapse
|
9
|
Pirovano P, Dorrian M, Shinde A, Donohoe A, Brady AJ, Moyna NM, Wallace G, Diamond D, McCaul M. A wearable sensor for the detection of sodium and potassium in human sweat during exercise. Talanta 2020; 219:121145. [PMID: 32887090 DOI: 10.1016/j.talanta.2020.121145] [Citation(s) in RCA: 51] [Impact Index Per Article: 12.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2020] [Revised: 05/02/2020] [Accepted: 05/08/2020] [Indexed: 12/20/2022]
Abstract
The SwEatch platform, a wearable sensor for sampling and measuring the concentration of electrolytes in human sweat in real time, has been improved in order to allow the sensing of two analytes. The solid contact ion-sensitive electrodes (ISEs) for the detection of Na+ and K+ have been developed in two alternative formulations, containing either poly(3,4-ethylenedioxythiophene) (PEDOT) or poly(3-octylthiophene-2,5-diyl) (POT) as a conductive polymer transducing component. The solution-processable POT formulation simplifies the fabrication process, and sensor to sensor reproducibility has been improved via partial automation using an Opentron® automated pipetting robot. The resulting electrodes showed good sensitivity (52.4 ± 6.3 mV/decade (PEDOT) and 56.4 ± 2.2 mV/decade (POT) for Na+ ISEs, and 45.7 ± 7.4 mV/decade (PEDOT) and 54.3 ± 1.5 mV/decade (POT) for K+) and excellent selectivity towards potential interferents present in human sweat (H+, Na+, K+, Mg2+, Ca2+). The 3D printed SwEatch platform has been redesigned to incorporate a double, mirrored fluidic unit which is capable of drawing sweat from the skin through passive capillary action and bring it in contact with two independent electrodes. The potentiometric signal generated by the electrodes is measured by an integrated electronics board, digitised and transmitted via Bluetooth to a laptop. The results obtained from on-body trials on athletes during cycling show a relatively small increase in sodium (1.89 mM-2.97 mM) and potassium (3.31 mM-7.25 mM) concentrations during the exercise period of up to 90 min.
Collapse
Affiliation(s)
- Paolo Pirovano
- Insight Centre for Data Analytics, National Centre for Sensor Research, Dublin City University, Glasnevin, Dublin 9, Ireland
| | - Matthew Dorrian
- Insight Centre for Data Analytics, National Centre for Sensor Research, Dublin City University, Glasnevin, Dublin 9, Ireland
| | - Akshay Shinde
- Insight Centre for Data Analytics, National Centre for Sensor Research, Dublin City University, Glasnevin, Dublin 9, Ireland
| | - Andrew Donohoe
- Insight Centre for Data Analytics, National Centre for Sensor Research, Dublin City University, Glasnevin, Dublin 9, Ireland
| | - Aidan J Brady
- School of Health and Human Performance, Dublin City University, Dublin 9, Ireland
| | - Niall M Moyna
- School of Health and Human Performance, Dublin City University, Dublin 9, Ireland
| | - Gordon Wallace
- ARC Centre of Excellence for Electromaterials Science, University of Wollongong, Wollongong, NSW, 2522, Australia
| | - Dermot Diamond
- Insight Centre for Data Analytics, National Centre for Sensor Research, Dublin City University, Glasnevin, Dublin 9, Ireland
| | - Margaret McCaul
- Insight Centre for Data Analytics, National Centre for Sensor Research, Dublin City University, Glasnevin, Dublin 9, Ireland.
| |
Collapse
|
10
|
Urbanowicz M, Pijanowska DG, Jasiński A, Ekman M, Bocheńska MK. A miniaturized solid-contact potentiometric multisensor platform for determination of ionic profiles in human saliva. J Solid State Electrochem 2019. [DOI: 10.1007/s10008-019-04429-9] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Abstract
Abstract
This paper describes a miniaturized multisensor platform (MP-ISES) consisting of electrodes: a reference one (RE) and ion-selective electrodes (ISEs) for monitoring Na+, K+, Ca2+, Mg2+, Cl−, and SCN− ions and pH in human saliva. Gold electrode surface was modified by deposition of two layers: electrosynthesized PEDOT:PSS forming an intermediate layer, and ion-selective membrane. The developed ISEs were characterized by a wide linear range and sensitivity consistent with the Nernst model. The entire MP-ISEs are characterized by satisfactory metrological parameters demonstrating their applicability in biomedical research, in particular in measurements concerning determination of ionic profiles of saliva. Saliva samples of 18 volunteers aged from 20 to 26 participating in a month experiment had been daily collected and investigated using the MP-ISEs assigned individually to each person. Personalized profiles of ions (ionograms) in saliva, such as Na+, K+, Ca2+, Mg2+, Cl−, SCN−, and H+, were obtained.
Collapse
|
11
|
Galiullin TM, Pokhvishcheva NV, Kalinichev AV, Peshkova MA. Evaluation of Ionic Liquids Based on Amino Acid Anions for Use in Liquid‐junction Free Reference Electrodes. ELECTROANAL 2019. [DOI: 10.1002/elan.201900125] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Affiliation(s)
- Timur M. Galiullin
- Chemistry InstituteSaint Petersburg State University 26 Universitetskiy prospect 198504 Saint Petersburg Russia
| | - Nadezhda V. Pokhvishcheva
- Chemistry InstituteSaint Petersburg State University 26 Universitetskiy prospect 198504 Saint Petersburg Russia
| | - Andrey V. Kalinichev
- Chemistry InstituteSaint Petersburg State University 26 Universitetskiy prospect 198504 Saint Petersburg Russia
| | - Maria A. Peshkova
- Chemistry InstituteSaint Petersburg State University 26 Universitetskiy prospect 198504 Saint Petersburg Russia
| |
Collapse
|
12
|
KOMODA M, SHITANDA I, HOSHI Y, ITAGAKI M. Fabrication and Characterization of a Fully Screen-Printed Ag/AgCl Reference Electrode Using Silica Gel Inks Exhibiting Instantaneous Usability and Long-Term Stability. ELECTROCHEMISTRY 2019. [DOI: 10.5796/electrochemistry.18-00075] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Affiliation(s)
- Masato KOMODA
- Department of Pure and Applied Chemistry, Faculty of Science and Technology, Tokyo University of Science
| | - Isao SHITANDA
- Department of Pure and Applied Chemistry, Faculty of Science and Technology, Tokyo University of Science
- Research Institute for Science and Technology, Tokyo University of Science
| | - Yoshinao HOSHI
- Department of Pure and Applied Chemistry, Faculty of Science and Technology, Tokyo University of Science
| | - Masayuki ITAGAKI
- Department of Pure and Applied Chemistry, Faculty of Science and Technology, Tokyo University of Science
- Research Institute for Science and Technology, Tokyo University of Science
| |
Collapse
|
13
|
|
14
|
Urbanowicz M, Jasiński A, Jasińska M, Drucis K, Ekman M, Szarmach A, Suchodolski R, Pomećko R, Bocheńska M. Simultaneous Determination of Na+, K+, Ca2+, Mg2+and Cl−in Unstimulated and Stimulated Human Saliva Using All Solid State Multisensor Platform. ELECTROANAL 2017. [DOI: 10.1002/elan.201700149] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Affiliation(s)
- Marcin Urbanowicz
- Department of Chemistry and Technology of Functional Materials, Chemical Faculty; Gdansk University of Technology; Narutowicza 11/12 80-233 Gdańsk Poland
| | - Artur Jasiński
- Department of Chemistry and Technology of Functional Materials, Chemical Faculty; Gdansk University of Technology; Narutowicza 11/12 80-233 Gdańsk Poland
| | - Małgorzata Jasińska
- Department of Chemistry and Technology of Functional Materials, Chemical Faculty; Gdansk University of Technology; Narutowicza 11/12 80-233 Gdańsk Poland
| | - Kamil Drucis
- Department of Surgical Oncology; Medical University of Gdansk; Debinki 7 80-952 Gdansk Poland
| | - Marcin Ekman
- Department of Surgical Oncology; Medical University of Gdansk; Debinki 7 80-952 Gdansk Poland
| | - Arkadiusz Szarmach
- Department of Surgical Oncology; Medical University of Gdansk; Debinki 7 80-952 Gdansk Poland
| | - Rafał Suchodolski
- Department of Surgical Oncology; Medical University of Gdansk; Debinki 7 80-952 Gdansk Poland
| | - Radosław Pomećko
- Department of Chemistry and Technology of Functional Materials, Chemical Faculty; Gdansk University of Technology; Narutowicza 11/12 80-233 Gdańsk Poland
| | - Maria Bocheńska
- Department of Chemistry and Technology of Functional Materials, Chemical Faculty; Gdansk University of Technology; Narutowicza 11/12 80-233 Gdańsk Poland
| |
Collapse
|
15
|
Affiliation(s)
- Eric Bakker
- Department of Inorganic and
Analytical Chemistry, University of Geneva, 1211 Geneva, Switzerland
| |
Collapse
|
16
|
Rahimi N, Doroodmand MM, Ghahremani A. Fabrication of a novel casein phosphopeptides/multi-walled carbon nanotubes/micro hybrid resin as mixed matrix membrane-junction reference electrode. J Electroanal Chem (Lausanne) 2015. [DOI: 10.1016/j.jelechem.2015.02.007] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
|
17
|
Hu J, Ho KT, Zou XU, Smyrl WH, Stein A, Bühlmann P. All-Solid-State Reference Electrodes Based on Colloid-Imprinted Mesoporous Carbon and Their Application in Disposable Paper-based Potentiometric Sensing Devices. Anal Chem 2015; 87:2981-7. [DOI: 10.1021/ac504556s] [Citation(s) in RCA: 78] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/17/2023]
Affiliation(s)
- Jinbo Hu
- Department
of Chemistry, University of Minnesota, 207 Pleasant Street SE, Minneapolis, Minnesota 55455, United States
| | - Kieu T. Ho
- Department
of Chemistry, University of Minnesota, 207 Pleasant Street SE, Minneapolis, Minnesota 55455, United States
| | - Xu U. Zou
- Department
of Chemistry, University of Minnesota, 207 Pleasant Street SE, Minneapolis, Minnesota 55455, United States
| | - William H. Smyrl
- Department
of Chemical Engineering and Materials Science, University of Minnesota, 421 Washington Avenue SE, Minneapolis, Minnesota 55455, United States
| | - Andreas Stein
- Department
of Chemistry, University of Minnesota, 207 Pleasant Street SE, Minneapolis, Minnesota 55455, United States
| | - Philippe Bühlmann
- Department
of Chemistry, University of Minnesota, 207 Pleasant Street SE, Minneapolis, Minnesota 55455, United States
| |
Collapse
|