1
|
Geballa-Koukoula A, Willemsen L, Beij E, van Hoof R, Elferink A, Geballa-Koukoulas K, Peters J, Blokland MH, Salentijn GI. Smartcard: an integrated approach for contaminant monitoring, from field to laboratory. Anal Bioanal Chem 2025; 417:69-82. [PMID: 39528785 PMCID: PMC11695648 DOI: 10.1007/s00216-024-05626-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2024] [Revised: 10/11/2024] [Accepted: 10/15/2024] [Indexed: 11/16/2024]
Abstract
Effective food safety monitoring requires a multi-step approach from farm to fork, involving different methods, ranging from convenient screening devices to sophisticated laboratory confirmatory testing. However, sample transportation to routine laboratories is time-consuming and expensive. Simplified on-site sampling followed by laboratory analysis offers a potential solution. Dried blood spot (DBS) cards ensure stability and ease of sample transportation and are used in clinical testing. However, the applicability of such an approach could be broader and include the storage of dried extract from more complex (solid) matrices. Therefore, a simplified approach is presented here, using DBS cards for on-site sampling and subsequent laboratory confirmation for food contaminants. To achieve this, an analytical tool (Smartcard) was designed using 3D-printing technology. As a proof of concept, the approach was applied to detect the pesticide fipronil, which is widely used in ornamental flower production to limit pests and on poultry farms. The Smartcard can securely store the sample extracts on a DBS card (dried extract spot (DExS) card), incorporate the lateral flow immunoassay (LFIA) and immediately provide an estimate of contamination levels. After simplified in-syringe extraction of the sample, the LFIA allows direct screening of fipronil (half maximum inhibitory concentration of 6.5 µg/l with calibration standards), and the same sample extract can be directly applied to the DExS card for storage and transport to the laboratory, where analyte re-extraction and instrumental analysis is performed using ultra high-pressure liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) detecting fipronil down to 0.8 µg/kg.
Collapse
Affiliation(s)
- Ariadni Geballa-Koukoula
- Wageningen Food Safety Research, Wageningen University and Research, P.O. Box 230, 6700 AE, Wageningen, The Netherlands
| | - Linda Willemsen
- Wageningen Food Safety Research, Wageningen University and Research, P.O. Box 230, 6700 AE, Wageningen, The Netherlands
| | - Erik Beij
- Wageningen Food Safety Research, Wageningen University and Research, P.O. Box 230, 6700 AE, Wageningen, The Netherlands
| | - Richard van Hoof
- Wageningen Food Safety Research, Wageningen University and Research, P.O. Box 230, 6700 AE, Wageningen, The Netherlands
| | - Alexander Elferink
- Wageningen Food Safety Research, Wageningen University and Research, P.O. Box 230, 6700 AE, Wageningen, The Netherlands
| | - Khalil Geballa-Koukoulas
- Laboratory of General and Agricultural Microbiology, Department of Crop Science, Agricultural University of Athens, Iera Odos 75, 118 55, Athens, Greece
| | - Jeroen Peters
- Wageningen Food Safety Research, Wageningen University and Research, P.O. Box 230, 6700 AE, Wageningen, The Netherlands
| | - Marco H Blokland
- Wageningen Food Safety Research, Wageningen University and Research, P.O. Box 230, 6700 AE, Wageningen, The Netherlands
| | - Gert Ij Salentijn
- Wageningen Food Safety Research, Wageningen University and Research, P.O. Box 230, 6700 AE, Wageningen, The Netherlands.
- Laboratory of Organic Chemistry, Wageningen University, Stippeneng 4, 6708 WE, Wageningen, The Netherlands.
| |
Collapse
|
2
|
Belhameid A, Casado-Carmona FA, Megriche A, López-Lorente ÁI, Lucena R, Cárdenas S. On-site extraction of benzophenones from swimming pool water using hybrid tapes based on the integration of hydrophilic-lipophilic balance microparticles and an outer magnetic nanometric domain. Mikrochim Acta 2024; 191:513. [PMID: 39105990 PMCID: PMC11303577 DOI: 10.1007/s00604-024-06586-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2024] [Accepted: 07/22/2024] [Indexed: 08/07/2024]
Abstract
An on-site extraction device is presented consisting of scotch tape modified with concentric domains of micrometric hydrophilic-lipophilic balance (HLB) particles surrounded by a ring of nanometric magnetic ones. On the one hand, HLB microparticles are readily available at the surface of the tape, exposed to interact with the target analytes, being responsible for the extraction capacity of the sorptive phase. On the other hand, the presence of magnetic nanoparticles enables the attachment of the modified tape onto a metallic screw via a magnet, which is then coupled to a wireless drill, enabling the stirring of the microextraction device. Both are simply fixed to the cost-effective, flexible, and versatile support, i.e., scotch tape, owing to their adhesive properties. The microextraction device has been applied to the determination of six benzophenones in swimming pool water samples. The variables that may affect the extraction process have been evaluated. Under the optimum conditions and using liquid chromatography-tandem mass spectrometry as the instrumental technique, the method provided a limit of detection of 0.03 µg L-1. The intra-day precision, evaluated at three different concentration levels and expressed as relative standard deviation, was lower than 10%, which also comprises the variability within single-use sorptive tapes. The accuracy, calculated with spiked samples and expressed as relative recovery, ranged from 71 to 138%. The method was applied to the analysis of swimming pool water, revealing the presence of such compounds.
Collapse
Affiliation(s)
- Ahmed Belhameid
- Affordable and Sustainable Sample Preparation (AS2P) Research Group, Departamento de Química Analítica, Instituto Químico para la Energía y el Medioambiente IQUEMA, Universidad de Córdoba, Campus de Rabanales, Edificio Marie Curie, E-14071, Córdoba, Spain
- Laboratory of Applied Mineral Chemistry, Faculty of Sciences of Tunis, University of Tunis El Manar, University, Campus El Manar 1, 2092, Tunis, Tunisia
| | - Francisco Antonio Casado-Carmona
- Affordable and Sustainable Sample Preparation (AS2P) Research Group, Departamento de Química Analítica, Instituto Químico para la Energía y el Medioambiente IQUEMA, Universidad de Córdoba, Campus de Rabanales, Edificio Marie Curie, E-14071, Córdoba, Spain
- FI-TRACE Group, Department of Chemistry, Faculty of Science, University of the Balearic Islands, Illes Balears, Carretera de Valldemossa Km 7.5, E-07122, Palma de Mallorca, Spain
| | - Adel Megriche
- Laboratory of Applied Mineral Chemistry, Faculty of Sciences of Tunis, University of Tunis El Manar, University, Campus El Manar 1, 2092, Tunis, Tunisia
| | - Ángela Inmaculada López-Lorente
- Affordable and Sustainable Sample Preparation (AS2P) Research Group, Departamento de Química Analítica, Instituto Químico para la Energía y el Medioambiente IQUEMA, Universidad de Córdoba, Campus de Rabanales, Edificio Marie Curie, E-14071, Córdoba, Spain.
| | - Rafael Lucena
- Affordable and Sustainable Sample Preparation (AS2P) Research Group, Departamento de Química Analítica, Instituto Químico para la Energía y el Medioambiente IQUEMA, Universidad de Córdoba, Campus de Rabanales, Edificio Marie Curie, E-14071, Córdoba, Spain.
| | - Soledad Cárdenas
- Affordable and Sustainable Sample Preparation (AS2P) Research Group, Departamento de Química Analítica, Instituto Químico para la Energía y el Medioambiente IQUEMA, Universidad de Córdoba, Campus de Rabanales, Edificio Marie Curie, E-14071, Córdoba, Spain
| |
Collapse
|
3
|
Ye L, Li J, Gong S, Herczegh SM, Zhang Q, Letcher RJ, Su G. Established and emerging organophosphate esters (OPEs) and the expansion of an environmental contamination issue: A review and future directions. JOURNAL OF HAZARDOUS MATERIALS 2023; 459:132095. [PMID: 37523961 DOI: 10.1016/j.jhazmat.2023.132095] [Citation(s) in RCA: 24] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/04/2023] [Revised: 07/13/2023] [Accepted: 07/18/2023] [Indexed: 08/02/2023]
Abstract
The list of organophosphate esters (OPEs) reported in the environment continues to expand as evidenced by the increasing number of OPE studies in the literature. However, there remains a general dearth of information on more recently produced and used OPEs that are proving to be emerging environmental contaminants. The present review summarizes the available studies in a systematic framework of the current state of knowledge on the analysis, environmental fate, and behavior of emerging OPEs. This review also details future directions to better understand emerging OPEs in the environment. Firstly, we make recommendations that the current structural/practical abbreviations and naming of OPEs be revised and updated. A chemical database (CDB) containing 114 OPEs is presently established based on the suspect list from the current scientific literature. There are 12 established OPEs and a total of 83 emerging OPEs that have been reported in human and/or biota samples. Of the emerging OPEs more than 80% have nearly 100% detection frequencies in samples of certain environmental media including indoor air, wastewater treatment plants, sediment, and fish. In contrast to OPEs considered established contaminants, most emerging OPEs have been identified more recently due to the more pervasive use of high-resolution mass spectrometry (HRMS) based approaches and especially gas or liquid chromatography coupled with HRMS-based non-target analysis (NTA) of environmental sample fractions. Intentional/unintentional industrial use and non-industrial formation are sources of emerging OPEs in the environment. Predicted physical-chemical properties in silico of newer, molecularly larger and more oligomeric OPEs strongly suggest that some compounds such as bisphenol A diphenyl phosphate (BPA-DPP) are highly persistent, bioaccumulative and/or toxic. Limited information on laboratory-based toxicity data has shown that some emerging OPEs elicit harmful effects such as cytotoxicity, development toxicity, hepatotoxicity, and endocrine disruption in exposed humans and mammals. Established, and to a much lesser degree emerging OPEs, have also been shown to transform and degrade in biota and possibly alter their toxicological effects. Research on emerging OPE contaminants is presently limited and more study is warranted on sample analysis methods, source apportionment, transformation processes, environmental behavior, biomarkers of exposure and toxicity.
Collapse
Affiliation(s)
- Langjie Ye
- Key Laboratory of Environmental Remediation and Ecological Health, Ministry of Industry and Information Technology, School of Environmental and Biological Engineering, Nanjing University of Science and Technology, Nanjing 210094, China
| | - Jianhua Li
- Key Laboratory of Environmental Remediation and Ecological Health, Ministry of Industry and Information Technology, School of Environmental and Biological Engineering, Nanjing University of Science and Technology, Nanjing 210094, China
| | - Shuai Gong
- Key Laboratory of Environmental Remediation and Ecological Health, Ministry of Industry and Information Technology, School of Environmental and Biological Engineering, Nanjing University of Science and Technology, Nanjing 210094, China
| | - Sofia M Herczegh
- Ecotoxicology and Wildlife Health Division, Wildlife and Landscape Directorate, Science and Technology Branch, Environment and Climate Change Canada, National Wildlife Research Centre, Carleton University, Ottawa, ON, Canada; Department of Chemistry, Carleton University, Ottawa, ON, Canada
| | - Qi Zhang
- Key Laboratory of Environmental Remediation and Ecological Health, Ministry of Industry and Information Technology, School of Environmental and Biological Engineering, Nanjing University of Science and Technology, Nanjing 210094, China
| | - Robert J Letcher
- Ecotoxicology and Wildlife Health Division, Wildlife and Landscape Directorate, Science and Technology Branch, Environment and Climate Change Canada, National Wildlife Research Centre, Carleton University, Ottawa, ON, Canada; Department of Chemistry, Carleton University, Ottawa, ON, Canada
| | - Guanyong Su
- Key Laboratory of Environmental Remediation and Ecological Health, Ministry of Industry and Information Technology, School of Environmental and Biological Engineering, Nanjing University of Science and Technology, Nanjing 210094, China.
| |
Collapse
|
4
|
Jiang J, Zhang M, Xu Z, Yang Y, Wang Y, Zhang H, Yu K, Kan G, Jiang Y. Recent Advances in Catecholamines Analytical Detection Methods and Their Pretreatment Technologies. Crit Rev Anal Chem 2023; 55:1-20. [PMID: 37733491 DOI: 10.1080/10408347.2023.2258982] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/23/2023]
Abstract
Catecholamines (CAs), including adrenaline, noradrenaline, and dopamine, are neurotransmitters and hormones that play a critical role in regulating the cardiovascular system, metabolism, and stress response in the human body. As promising methods for real-time monitoring of catecholamine neurotransmitters, LC-MS detectors have gained widespread acceptance and shown significant progress over the past few years. Other detection methods such as fluorescence detection, colorimetric assays, surface-enhanced Raman spectroscopy, and surface plasmon resonance spectroscopy have also been developed to varying degrees. In addition, efficient pretreatment technology for CAs is flourishing due to the increasing development of many highly selective and recoverable materials. There are a few articles that provide an overview of electrochemical detection and efficient enrichment, but a comprehensive summary focusing on analytical detection technology is lacking. Thus, this review provides a comprehensive summary of recent analytical detection technology research on CAs published between 2017 and 2022. The advantages and limitations of relevant methods including efficient pretreatment technologies for biological matrices and analytical methods used in combination with pretreatment technology have been discussed. Overall, this review article provides a better understanding of the importance of accurate CAs measurement and offers perspectives on the development of novel methods for disease diagnosis and research in this field.
Collapse
Affiliation(s)
- Jie Jiang
- School of Marine Science and Technology, Harbin Institute of Technology (WeiHai), Weihai, Shandong, China
- School of Chemistry and Chemical Engineering, Harbin Institute of Technology, Harbin, Heilongjiang, China
- State Key Laboratory of Urban Water Resource and Environment, Harbin Institute of Technology, Harbin, Heilongjiang, China
| | - Meng Zhang
- School of Marine Science and Technology, Harbin Institute of Technology (WeiHai), Weihai, Shandong, China
- School of Chemistry and Chemical Engineering, Harbin Institute of Technology, Harbin, Heilongjiang, China
| | - Zhilong Xu
- School of Marine Science and Technology, Harbin Institute of Technology (WeiHai), Weihai, Shandong, China
- School of Chemistry and Chemical Engineering, Harbin Institute of Technology, Harbin, Heilongjiang, China
| | - Yali Yang
- School of Marine Science and Technology, Harbin Institute of Technology (WeiHai), Weihai, Shandong, China
- School of Chemistry and Chemical Engineering, Harbin Institute of Technology, Harbin, Heilongjiang, China
| | - Yimeng Wang
- School of Chemistry and Chemical Engineering, Harbin Institute of Technology, Harbin, Heilongjiang, China
- Elite Engineer School, Harbin Institute of Technology, Harbin, Heilongjiang, China
| | - Hong Zhang
- School of Marine Science and Technology, Harbin Institute of Technology (WeiHai), Weihai, Shandong, China
| | - Kai Yu
- School of Marine Science and Technology, Harbin Institute of Technology (WeiHai), Weihai, Shandong, China
| | - Guangfeng Kan
- School of Marine Science and Technology, Harbin Institute of Technology (WeiHai), Weihai, Shandong, China
| | - Yanxiao Jiang
- School of Marine Science and Technology, Harbin Institute of Technology (WeiHai), Weihai, Shandong, China
| |
Collapse
|
5
|
Rodríguez-Palma CE, Herráez-Hernández R, Campíns-Falcó P. A modified micro-solid phase extraction device for in-port elution and injection into portable liquid chromatography: A proof-of-concept study. J Chromatogr A 2023; 1705:464216. [PMID: 37480726 DOI: 10.1016/j.chroma.2023.464216] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2023] [Revised: 07/11/2023] [Accepted: 07/13/2023] [Indexed: 07/24/2023]
Abstract
A micro-solid phase extraction (micro-SPE) device packed with a C18 sorbent (10 mg) has been developed for the enrichment and purification of organic water pollutants prior to their analysis using a portable liquid chromatograph with a dual UV detector. To this end, the sorbent was immobilized at the inlet of a 4 mm syringe filter (0.20 µm), which was modified to reduce its internal volume. The filter was coupled to the needle of the chromatograph. After loading the sample and cleaning the sorbent for analyte purification, the device was installed into the injection port of the chromatograph, and the target compounds were desorbed and transferred directly to the chromatographic column with a small volume of organic solvent. Under optimized conditions, sample volumes as large as 50 mL could be processed with the micro-SPE device, while the analytes were desorbed with only 60 µL of methanol. As a result, efficient preconcentration could be reached, as demonstrated for different water contaminants, namely aclonifen, bifenox, tritosulfuron, triflusulfuron-methyl and caffeine. The proposed micro-SPE device was applied to the analysis of different types of water (river, well, sea, ditch and wastewater). The recoveries of the target compounds in samples ranged from 76 % to 109 %, which allowed their detection at low to sub µg/L levels. All operations were carried out manually, and thus, no additional laboratory instruments such as centrifuges, stirrers or evaporators were required. This proof-of-concept study shows that the proposed micro-SPE approach can be considered a reliable and effective option for the on-site analysis of pollutants in environmental water samples by portable liquid chromatography.
Collapse
Affiliation(s)
- C E Rodríguez-Palma
- MINTOTA Research Group, Departament de Química Analítica, Facultat de Química. Universitat de València. Dr. Moliner 50, 46100-Burjassot, València, Spain
| | - R Herráez-Hernández
- MINTOTA Research Group, Departament de Química Analítica, Facultat de Química. Universitat de València. Dr. Moliner 50, 46100-Burjassot, València, Spain.
| | - P Campíns-Falcó
- MINTOTA Research Group, Departament de Química Analítica, Facultat de Química. Universitat de València. Dr. Moliner 50, 46100-Burjassot, València, Spain
| |
Collapse
|
6
|
Qi M, Li Y, Zhu Z, Du B, Chen D. Current Sample Preparation Methods and Determination Techniques for the Determination of Phthalic Acid Ester Plasticizers in Edible Oils. Molecules 2023; 28:5106. [PMID: 37446766 DOI: 10.3390/molecules28135106] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2023] [Revised: 06/22/2023] [Accepted: 06/27/2023] [Indexed: 07/15/2023] Open
Abstract
In the process of production, processing, transportation, and storage of edible oils, the oils inevitably come into contact with plastic products. As a result, plasticizers migrate into edible oils, are harmful to human health, and can exhibit reproductive toxicity. Therefore, the determination of plasticizers in edible oils is very important, and a series of sample preparation methods and determination techniques have been developed for the determination of plasticizers in edible oils. Phthalic acid ester (PAE) plasticizers are the most widely used among all plasticizers. This review aims to provide a comprehensive overview of the sample preparation methods and detection techniques reported for the determination of PAEs in edible oils since 2010, focusing on sample preparation methods of edible oils combined with various separation-based analytical techniques, such as gas chromatography (GC) and liquid chromatography (LC) with different detectors. Furthermore, the advantages, disadvantages, and limitations of these techniques as well as the prospective future developments are also discussed.
Collapse
Affiliation(s)
- Menghui Qi
- School of Pharmaceutical Sciences, Zhengzhou University, Zhengzhou 450001, China
| | - Yanyan Li
- School of Pharmaceutical Sciences, Zhengzhou University, Zhengzhou 450001, China
| | - Zheng Zhu
- School of Pharmaceutical Sciences, Zhengzhou University, Zhengzhou 450001, China
| | - Bin Du
- School of Pharmaceutical Sciences, Zhengzhou University, Zhengzhou 450001, China
- Key Laboratory of Targeting Therapy and Diagnosis for Critical Diseases of Henan Province, Zhengzhou 450001, China
| | - Di Chen
- School of Pharmaceutical Sciences, Zhengzhou University, Zhengzhou 450001, China
- Key Laboratory of Targeting Therapy and Diagnosis for Critical Diseases of Henan Province, Zhengzhou 450001, China
| |
Collapse
|
7
|
Thapa B, Hsieh SA, Bell DS, Anderson JL. Monitoring the liberation of volatile organic compounds during fused deposition modeling three dimensional printing using solid-phase microextraction coupled to gas chromatography/mass spectrometry. J Chromatogr A 2023; 1693:463886. [PMID: 36870231 DOI: 10.1016/j.chroma.2023.463886] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2023] [Revised: 02/14/2023] [Accepted: 02/18/2023] [Indexed: 02/23/2023]
Abstract
Three-dimensional (3D) printers have gained tremendous popularity and are being widely used in offices, laboratories, and private homes. Fused deposition modeling (FDM) is among the most commonly used mechanisms by desktop 3D printers in indoor settings and relies on the extrusion and deposition of heated thermoplastic filaments, resulting in the liberation of volatile organic compounds (VOCs). With the growing use of 3D printers, concerns regarding human health have risen as the exposure to VOCs may cause adverse health effects. Therefore, it is important to monitor VOC liberation during printing and to correlate it to filament composition. In this study, VOCs liberated with a desktop printer were measured by solid-phase microextraction (SPME) combined with gas chromatography/mass spectrometry (GC/MS). SPME fibers featuring sorbent coatings of varied polarity were chosen for the extraction of VOCs liberated from acrylonitrile butadiene styrene (ABS), tough polylactic acid, and copolyester+ (CPE+) filaments. It was found that for all three filaments tested, longer print times resulted in a greater number of extracted VOCs. The ABS filament liberated the most VOCs while the CPE+ filaments liberated the fewest VOCs. Through the use of hierarchical cluster analysis and principal component analysis, filaments as well as fibers could be differentiated based on the liberated VOCs. This study demonstrates that SPME is a promising tool to sample and extract VOCs liberated during 3D printing under non-equilibrium conditions and can be used to aid in tentative identification of the VOCs when coupled to gas chromatography-mass spectrometry.
Collapse
Affiliation(s)
- Bhawana Thapa
- Department of Chemistry, Iowa State University, Ames, Iowa 50011 USA
| | - Shu-An Hsieh
- Department of Chemistry, Iowa State University, Ames, Iowa 50011 USA
| | - David S Bell
- Restek Corporation, 110 Benner Circle, Bellefonte, Pennsylvania 16823, USA
| | - Jared L Anderson
- Department of Chemistry, Iowa State University, Ames, Iowa 50011 USA.
| |
Collapse
|
8
|
Development of a headspace-solid phase microextraction gas chromatography-high resolution mass spectrometry method for analyzing volatile organic compounds in urine: Application in breast cancer biomarker discovery. Clin Chim Acta 2023; 540:117236. [PMID: 36716910 DOI: 10.1016/j.cca.2023.117236] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2022] [Revised: 01/06/2023] [Accepted: 01/24/2023] [Indexed: 02/01/2023]
Abstract
BACKGROUND AND AIM Breast cancer (BC) is the leading cause of cancer-related death in females. The development of non-invasive methods for the early diagnosis of BC still remains challenge. Here, we aimed to discover the urinary volatile organic compounds (VOCs) pattern of BC patients and identify potential VOC biomarkers for BC diagnosis. METHODS Urine samples were analyzed by headspace-solid phase microextraction (HS-SPME) combined with gas chromatography-high resolution mass spectrometry (GC-HRMS). To assure reliable analysis, the factors influencing HS-SPME extraction efficiency were comprehensively investigated and optimized by combing the Plackett-Burman design (PBD) with the central composite design (CCD). The established HS-SPME/GC-HRMS method was validated and applied to analyze urine samples from BC patients (n = 80) and healthy controls (n = 88). RESULTS A total number of 134 VOCs belonging to distinct chemical classes were identified by GC-HRMS. BC patients demonstrated unique urinary VOCs pattern. Orthogonal partial least squares-discriminant analysis (OPLS-DA) showed a clear separation between BC patients and healthy controls. Eight potential VOC biomarkers were identified using multivariate and univariate statistical analysis. The predictive ability of candidate VOC biomarkers was further investigated by the random forest (RF) algorithm. The candidate VOC biomarkers yielded 76.3% sensitivity and 85.4% specificity on the training set, and achieved 76.0% sensitivity and 92.3% specificity on the validation set. CONCLUSIONS Overall, this work not only established a standardized HS-SPME/GC-HRMS approach for urinary VOCs analysis, but also highlighted the value of urinary VOCs for BC diagnosis. The knowledge gained from this study paves the way for early diagnosis of BC using urine in a non-invasive manner.
Collapse
|
9
|
Kenessov B, Kapar A. Optimization of headspace solid-phase microextraction of volatile organic compounds from dry soil samples by porous coatings using COMSOL Multiphysics. CHEMICAL BULLETIN OF KAZAKH NATIONAL UNIVERSITY 2022. [DOI: 10.15328/cb1300] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022] Open
Abstract
Headspace solid-phase microextraction (HSSPME) is one of the simplest and cost-efficient sample preparation approaches for determination of volatile organic compounds (VOCs) in soil. This study was aimed at the development of the model for numerical optimization of HSSPME of volatile organic compounds from dry soil samples by porous coatings using COMSOL Multiphysics (CMP). ‘Transport of Diluted Species in Porous Medium’ physics was used for modeling. Effect of sample mass, pressure, fiber-headspace and soil-headspace distribution constants on extraction profiles and time of 95% equilibrium has been studied using the developed model. Equilibrium extraction under atmospheric pressure (1 atm) can take up to 97 min, while under vacuum (0.0313 atm) – 2.3 min. Equilibration time under vacuum was 42-43 times lower than under 1 atm at all studied distribution constants and sample masses. The developed model was modified for optimization of pre-incubation time using ‘Transport of Diluted Species’ physics. According to the obtained plots, 95% equilibration time can reach 13.3 min and depends on both sample mass and soil-headspace distribution constant of the analyte. The developed model can be recommended for optimization of pressure, preincubation and extraction time when fiber-headspace and soil-headspace distribution constants, soil porosity and density are known.
Collapse
|
10
|
|
11
|
Portable stirring device for the on-site extraction of environmental waters using magnetic hydrophilic-lipophilic balance tape. Anal Chim Acta 2022; 1189:339186. [PMID: 34815052 DOI: 10.1016/j.aca.2021.339186] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2021] [Revised: 10/12/2021] [Accepted: 10/16/2021] [Indexed: 12/17/2022]
Abstract
The spatial heterogeneity of environmental systems makes sampling at multiple locations crucial to provide complete and representative information. The on-site application of an extraction technique simplifies the sampling logistics, increasing sample integrity during transportation and storage. This article presents a portable, simple, and low-cost device capable of performing the simultaneous on-site extraction of several environmental water samples. The device consists of a small electric motor integrated into the plastic cap of a conventional glass bottle and operated with a portable battery. The electric motor provides stirring to a novel magnetic sorptive phase based on the deposition of hydrophilic-lipophilic balance (HLB) particles over a magnetic tape. The use of open technology makes the device globally affordable. In this first approach, the isolation and preconcentration of atrazine and simazine have been selected as proof of concept. Using an internal standard made unnecessary the adjustment of the ionic strength before the extraction, thus simplifying the analytical procedure. Under the optimum conditions and using direct infusion mass spectrometry as the instrumental technique, detection limits as low as 15 ng/L were obtained. The precision calculated at three different levels was better than 8.3%. The accuracy, calculated with spiked samples, indicates the applicability of the approach for environmental water analysis.
Collapse
|
12
|
Wang H, Yang M, Wang D, Li K, Wang S, Liu H. Ionic liquid-functionalized poly- N-phenylpyrrole coated on a NiTi alloy substrate for highly efficient solid-phase microextraction. NEW J CHEM 2022. [DOI: 10.1039/d1nj05398a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
TiO2–NiO composite nanoflakes were in situ grown, followed by electrochemical polymerization of [C4MIM]PF6@PPPy as a fiber coating for solid phase microextraction.
Collapse
Affiliation(s)
- Huiju Wang
- College of Chemistry and Chemical Engineering, Qinghai Minzu University, Xining 810007, China
- Key Lab of Resource Chemistry & Environmental Protection of Qinhai, Xining 810007, China
| | - Minghong Yang
- College of Chemistry and Chemical Engineering, Qinghai Minzu University, Xining 810007, China
| | - Dongdong Wang
- College of Chemistry and Chemical Engineering, Qinghai Minzu University, Xining 810007, China
| | - Kang Li
- College of Chemistry and Chemical Engineering, Qinghai Minzu University, Xining 810007, China
| | - Shoujia Wang
- College of Chemistry and Chemical Engineering, Qinghai Minzu University, Xining 810007, China
| | - Hailan Liu
- College of Chemistry and Chemical Engineering, Qinghai Minzu University, Xining 810007, China
| |
Collapse
|
13
|
Ghorbani M, Mohammadi P, Keshavarzi M, Ziroohi A, Mohammadi M, Aghamohammadhasan M, Pakseresht M. Developments of Microextraction (Extraction) Procedures for Sample Preparation of Antidepressants in Biological and Water Samples, a Review. Crit Rev Anal Chem 2021; 53:1285-1312. [PMID: 34955046 DOI: 10.1080/10408347.2021.2018648] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/24/2023]
Abstract
Antidepressants are an important class of drugs to treat various types of depression. The determination of antidepressants is crucial in biological samples to control adverse effects in humans and study pharmacokinetics and bioavailability. Direct measurement of antidepressants in biological and water samples is a considerable challenge for analysts due to their low concentration, the high matrix effects of real samples, and the presence of metabolites of these drugs in biological samples. The challenge leads to using sample preparation processes as a critical step in determining antidepressants. Extraction and microextraction procedures have been widely utilized as sample preparation procedures for these drugs. The purposes of extraction or microextraction methods for antidepressant medications are to preconcentrate the analyte, reduce the matrix effects, increase the selectivity of the procedures, and convert the sample to a suitable format for introducing it into detection systems. In the review, the various extraction and microextraction methods of these drugs in biological, real water, and wastewater samples were investigated. The theory of each technique was briefly addressed to understand the features and factors affecting each method. The extraction and microextraction methods were classified based on their application for antidepressants, and the advantages and disadvantages of each technique were reviewed. The new developments to overcome the limitations of each procedure were discussed. The investigation indicated the number of applications of liquid-phase microextraction for extracting antidepressants has been almost equal to that of solid-phase microextraction.
Collapse
Affiliation(s)
- Mahdi Ghorbani
- Department of Chemistry, Faculty of Sciences, Ferdowsi University of Mashhad, Mashhad, Iran
| | - Parisa Mohammadi
- Cellular and Molecular Research Center, Sabzevar University of Medical Sciences, Faculty of Health, Sabzevar, Iran
| | - Majid Keshavarzi
- Cellular and Molecular Research Center, Sabzevar University of Medical Sciences, Faculty of Health, Sabzevar, Iran
| | - Aliakbar Ziroohi
- Department of biology, Mashhad Branch, Islamic Azad University, Mashhad, Iran
| | - Morteza Mohammadi
- School of Medicine, Sechenov University of Medical Sciences, Moscow, Russia
| | | | - Maryam Pakseresht
- Department of Chemistry, Faculty of Arts and Sciences, Near East University, Nicosia, Cyprus
| |
Collapse
|
14
|
Larki A, Saghanezhad SJ, Ghomi M. Recent advances of functionalized SBA-15 in the separation/preconcentration of various analytes: A review. Microchem J 2021. [DOI: 10.1016/j.microc.2021.106601] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
15
|
Kazemi MS, Jamali MR, Yazdani V. Application of a synthetic ligand in rapidly synergistic cloud point method for separation and preconcentration trace amounts of copper of water samples. SEPARATION SCIENCE PLUS 2021. [DOI: 10.1002/sscp.202100029] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Affiliation(s)
- Malihe Samadi Kazemi
- Department of sciences, Faculty of Chemistry, Bojnourd branch Islamic Azad University Bojnourd Iran
| | | | - Vali Yazdani
- Department of Chemistry Payame Noor University Tehran Iran
| |
Collapse
|
16
|
Magnetic paper-based sorptive phase for enhanced mass transference in stir membrane environmental samplers. Talanta 2021; 228:122217. [DOI: 10.1016/j.talanta.2021.122217] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2020] [Revised: 01/27/2021] [Accepted: 02/09/2021] [Indexed: 02/06/2023]
|
17
|
Preparation of environmental samples for chemical speciation of metal/metalloids: A review of extraction techniques. Talanta 2021; 226:122119. [PMID: 33676674 DOI: 10.1016/j.talanta.2021.122119] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2020] [Revised: 01/11/2021] [Accepted: 01/12/2021] [Indexed: 11/20/2022]
Abstract
Chemical speciation is a relevant topic in environmental chemistry since the (eco)toxicity, bio (geo)chemical cycles, and mobility of a given element depend on its chemical forms (oxidation state, organic ligands, etc.). Maintaining the chemical stability of the species and avoiding equilibrium disruptions during the sample treatment is one of the biggest challenges in chemical speciation, especially in environmental matrices where the level of concomitants/interferents is normally high. To achieve this task, strategies based on chemical properties of the species can be carried out and pre-concentration techniques are often needed due to the low concentration ranges of many species (μg L-1 - ng L-1). Due to the significance of the topic and the lack of reviews dealing with sample preparation of metal (loid)s (usually, sample preparation reviews focus on the total metal content), this work is presented. This review gives an up-to-date overview of the most common sample preparation techniques for environmental samples (water, soil, and sediments), with a focus on speciation of metal/metalloids and determination by spectrometric techniques. Description of the methods is given, and the most recent applications (last 10 years) are presented.
Collapse
|
18
|
A comprehensive review on application of the syringe in liquid- and solid-phase microextraction methods. JOURNAL OF THE IRANIAN CHEMICAL SOCIETY 2021. [DOI: 10.1007/s13738-020-02025-7] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|
19
|
Fuller J, White D, Yi H, Colley J, Vickery Z, Liu S. Analysis of volatile compounds causing undesirable odors in a polypropylene - high-density polyethylene recycled plastic resin with solid-phase microextraction. CHEMOSPHERE 2020; 260:127589. [PMID: 32682135 DOI: 10.1016/j.chemosphere.2020.127589] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/10/2020] [Revised: 06/27/2020] [Accepted: 06/30/2020] [Indexed: 06/11/2023]
Abstract
Although recycled plastics provide a low-cost and environmentally friendly alternative for many applications, their desirability is significantly limited by the presence of unpleasant odors from volatile organic compounds (VOCs). In this work, a headspace solid-phase microextraction (HS-SPME) coupled with gas chromatography-mass spectrometry (GC-MS) method was optimized to analyze volatile compounds from an odorous recycled plastic resin which was roughly composed of 85-90% polypropylene (PP) and 15-10% high-density polyethylene (HDPE). A large variety of aliphatic hydrocarbons and 13 additive residues were detected. Statistical tools were employed to screen the VOCs and successfully identified three components, i.e., 2,4-dimethyl-heptane, 4-methyl-octane and octamethylcyclotetrasiloxane (D4), which were significantly related to the odor intensity of the recycled plastic resin (p-values < 0.05). 2,4-Dimethyl-heptane has a strong, pungent plastic smell, which is very similar to the odor of the recycled resin. It is identified as a major source of the odor. Past relevant research has not been able to establish a direct link between an odorous compound and the undesirable odor of recycled plastic until now. 4-Methyl-octane was highly corelated to 2,4-dimethyl-heptane and somewhat contributed to the odor. D4 does not have an odor, but it may serve as an indicator of some odorous residues from personal care products.
Collapse
Affiliation(s)
- Jon Fuller
- Department of Chemistry and Physics, Troy University, AL, 36082, USA
| | - David White
- Department of Chemistry and Physics, Troy University, AL, 36082, USA
| | - Huijun Yi
- Department of Mathematics, Troy University, AL, 36082, USA
| | - Jason Colley
- Department of Chemistry and Physics, Troy University, AL, 36082, USA
| | - Zane Vickery
- Department of Chemistry and Physics, Troy University, AL, 36082, USA
| | - Shaoyang Liu
- Department of Chemistry and Physics, Troy University, AL, 36082, USA; Center for Materials and Manufacturing Sciences, Troy University, AL 36082, USA.
| |
Collapse
|
20
|
Tabibpour M, Yamini Y, Ahmadi SH, Esrafili A, Heydar KT, Mousavi SAJ, Baharfar M. Microextraction on a screw for determination of trace amounts of hexanal and heptanal as lung cancer biomarkers. J Pharm Biomed Anal 2020; 191:113528. [PMID: 32916561 DOI: 10.1016/j.jpba.2020.113528] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2020] [Revised: 07/31/2020] [Accepted: 07/31/2020] [Indexed: 11/18/2022]
Abstract
Solid phase microextraction on a screw was utilized for the extraction of hexanal and heptanal as lung cancer biomarkers from urine samples. Reduced graphene oxide (rGO) was coated on the surface of a stainless-steel set screw by electrophoretic deposition method. The screw was located inside a glass cover, and the created channel acted as the sample solution flow pass. A 5 mL glass syringe was connected to a syringe pump to direct the sample and the eluent through the channel. The extraction procedure was followed by gas chromatography/mass spectrometry (GC/MS) for separation and determination of the extracted aldehydes. The effective parameters on the extraction efficiencies of the analytes were identified and optimized. Under the optimal extraction conditions, the extraction time was as short as 10 min. The calibration curves indicated good linearity (R2 > 0.97) within the concentration range of 1.0-50 μg L-1. The obtained limits of detection (LODs) for hexanal and heptanal were down to 0.4 and 0.3 μg L-1, respectively. Considering the repeatability, simplicity, and eco-friendliness of this simple extraction method, it can be efficiently used for preconcentration of aldehydes in different samples.
Collapse
Affiliation(s)
- Mahmoud Tabibpour
- Chemistry & Chemical Engineering Research Center of Iran, P.O. Box 14334-186, Tehran, Iran
| | - Yadollah Yamini
- Department of Chemistry, Tarbiat Modares University, P.O. Box 14115-175, Tehran, Iran.
| | - Seyyed Hamid Ahmadi
- Chemistry & Chemical Engineering Research Center of Iran, P.O. Box 14334-186, Tehran, Iran.
| | - Ali Esrafili
- Department of Environmental Health Engineering, School of Public Health, Iran University of Medical Sciences, Tehran, Iran
| | - Kourosh Tabar Heydar
- Chemistry & Chemical Engineering Research Center of Iran, P.O. Box 14334-186, Tehran, Iran
| | - Seyed Ali Javad Mousavi
- Air Pollution Research Center, Department of Pulmonology, Iran University of Medical Sciences, Tehran, Iran
| | - Mahroo Baharfar
- Department of Chemistry, Tarbiat Modares University, P.O. Box 14115-175, Tehran, Iran
| |
Collapse
|
21
|
Liu P, Zhou H, Zhang L, Wang F, Wang X, Du X. Highly efficient solid-phase microextraction of polycyclic aromatic hydrocarbons in water based on worm-like nickel-titanium oxide nanocomposites coating grown on a nickel-titanium alloy wire by low-voltage anodization. J Sep Sci 2020; 44:628-635. [PMID: 33200880 DOI: 10.1002/jssc.202000871] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2020] [Revised: 11/12/2020] [Accepted: 11/13/2020] [Indexed: 12/20/2022]
Abstract
A novel worm-like nickel-titanium oxide nanocomposite coating was directly grown on a nickel-titanium alloy wire by low-voltage electrochemical anodization in alkaline ethylene glycol and water solution. The in situ growth of nickel-titanium oxide nanocomposites greatly depended on the volume ratio of ethylene glycol to water and temperature. Coupled to high-performance liquid chromatography with UV detection by static desorption in the mobile phase, the adsorption performance of the as-prepared fiber was evaluated for solid-phase microextraction of representative environmental analytes in water. The results indicate that the as-prepared fiber exhibits higher extraction capability for polycyclic aromatic hydrocarbons than commercial polydimethylsiloxane and polyacrylate fibers. After optimizing the extraction parameters, the calibration graphs of the developed method was linear in the range of 0.05-200 μg/L with correlation coefficients above 0.998. Limit of detection ranged from 0.013 to 0.145 μg/L for seven target analytes. Relative standard deviations of intraday and interday analyses varied from 4.0 to 5.3% and from 4.7 to 6.3% with the single fiber, respectively. The relative recoveries of 84.4-109% were achieved for highly efficient enrichment and determination of target analytes in spiked river and snow water. Moreover, the as-prepared fiber can be used more than 200 times.
Collapse
Affiliation(s)
- Pei Liu
- College of Chemistry and Chemical Engineering, Northwest Normal University, Lanzhou, P. R. China
| | - Hua Zhou
- College of Chemistry and Chemical Engineering, Northwest Normal University, Lanzhou, P. R. China
| | - Lei Zhang
- College of Chemistry and Chemical Engineering, Northwest Normal University, Lanzhou, P. R. China
| | - Feifei Wang
- College of Chemistry and Chemical Engineering, Northwest Normal University, Lanzhou, P. R. China
| | - Xuemei Wang
- College of Chemistry and Chemical Engineering, Northwest Normal University, Lanzhou, P. R. China.,Key Lab of Bioelectrochemistry & Environmental Analysis of Gansu, Lanzhou, P. R. China
| | - Xinzhen Du
- College of Chemistry and Chemical Engineering, Northwest Normal University, Lanzhou, P. R. China.,Key Lab of Bioelectrochemistry & Environmental Analysis of Gansu, Lanzhou, P. R. China
| |
Collapse
|
22
|
Escamilla-Lara KA, Heredia AC, Peña-Alvarez A, Ibarra IS, Barrado E, Rodriguez JA. Magnetic Solid-Phase Extraction Based on Poly 4-Vinyl Pyridine for HPLC-FLD Analysis of Naproxen in Urine Samples. MOLECULES (BASEL, SWITZERLAND) 2020; 25:molecules25122924. [PMID: 32630475 PMCID: PMC7355941 DOI: 10.3390/molecules25122924] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/03/2020] [Revised: 06/19/2020] [Accepted: 06/24/2020] [Indexed: 11/19/2022]
Abstract
A magnetic solid phase extraction technique followed by liquid chromatography with a fluorescence detector for naproxen analysis in human urine samples was developed. The method includes the extraction of naproxen with a magnetic solid synthetized with magnetite and poly 4-vinylpriridine, followed by the magnetic separation of the solid phase and desorption of the analyte with methanol. Under optimal conditions, the linear range of the calibration curve was 0.05–0.60 μg L−1, with a limit of detection of 0.02 μg L−1. In all cases values of repeatability were lower than 5.0% with recoveries of 99.4 ± 1.3%. Precision and accuracy values are adequate for naproxen (Npx) analysis in urine samples.
Collapse
Affiliation(s)
- Karen A. Escamilla-Lara
- Area Academica de Quimica, Universidad Autonoma del Estado de Hidalgo, Carretera Pachuca-Tulancingo Km. 4.5, Mineral de la Reforma 42184, HGO, Mexico; (K.A.E.-L.); (I.S.I.)
| | - Ana C. Heredia
- Facultad de Quimica, Departamento de Quimica Analitica, Universidad Nacional Autonoma de Mexico, Ciudad de Mexico 04510, Mexico; (A.C.H.); (A.P.-A.)
| | - Araceli Peña-Alvarez
- Facultad de Quimica, Departamento de Quimica Analitica, Universidad Nacional Autonoma de Mexico, Ciudad de Mexico 04510, Mexico; (A.C.H.); (A.P.-A.)
| | - Israel S. Ibarra
- Area Academica de Quimica, Universidad Autonoma del Estado de Hidalgo, Carretera Pachuca-Tulancingo Km. 4.5, Mineral de la Reforma 42184, HGO, Mexico; (K.A.E.-L.); (I.S.I.)
| | - Enrique Barrado
- Department of Analytical Chemistry, Facultad de Ciencias, Universidad de Valladolid, Campus Miguel Delibes, Calle Paseo de Belen, 7, 47011 Valladolid, Spain;
| | - Jose A. Rodriguez
- Area Academica de Quimica, Universidad Autonoma del Estado de Hidalgo, Carretera Pachuca-Tulancingo Km. 4.5, Mineral de la Reforma 42184, HGO, Mexico; (K.A.E.-L.); (I.S.I.)
- Correspondence: ; Tel.: +52-771717200 (ext. 2202)
| |
Collapse
|
23
|
Zakharkiv I, Zui M, Zaitsev V. Determination of Phthalate Esters in Water and Liquid Pharmaceutical Samples by Dispersive Liquid-Liquid Microextraction (DLLME) and Gas Chromatography with Flame Ionization Detection (GC-FID). ANAL LETT 2020. [DOI: 10.1080/00032719.2019.1711384] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
Affiliation(s)
- Igor Zakharkiv
- Department of Chemistry, Taras Shevchenko National University of Kyiv, Kyiv, Ukraine
| | - Maryna Zui
- Department of Chemistry, Taras Shevchenko National University of Kyiv, Kyiv, Ukraine
| | - Vladimir Zaitsev
- Department of Chemistry, Pontifícia Universidade Católica do Rio de Janeiro, Brazil, Rio de Janeiro, RJ, Brasil
| |
Collapse
|
24
|
Modulation of feed composition is able to make hens less attractive to the poultry red mite Dermanyssus gallinae. Parasitology 2019; 147:171-181. [PMID: 31559942 DOI: 10.1017/s0031182019001379] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
The poultry red mite (PRM) is an obligatory haematophagous pest that causes substantial economic losses in poultry worldwide. The PRM does not live on the host but in the bird's environment and must find its host remotely. Hence, manipulating chicken odours is of interest. Several crude plant-originating volatile organic compounds (VOCs) have already been shown as repellent to Dermanyssus gallinae. We aimed to test whether these VOCs can interfere with PRM host-seeking behaviour by their oral administration to the poultry. The objectives were to determine (1) if hen odours are modified by supplemented feed ingestion and (2) if such treatment makes hens less attractive to the PRM. Chemical characterization by gas chromatography-mass spectrometry of the hen odour was conducted before and after the hens ingested the supplemented feed. The chromatograms obtained show that hen odour was substantially modified after the hens consumed it. Among the molecules recurrently detected from the supplemented hens, 26% were nearly absent in the unsupplemented hens. Behavioural choice tests to compare the effect of the modified and unmodified-host odours on the PRM show that some of the plant-originating emitted VOCs and the modified whole-hen odours were repellent to the PRM.
Collapse
|
25
|
Taylor AC, Fones GR, Vrana B, Mills GA. Applications for Passive Sampling of Hydrophobic Organic Contaminants in Water—A Review. Crit Rev Anal Chem 2019; 51:20-54. [DOI: 10.1080/10408347.2019.1675043] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Affiliation(s)
- Adam C. Taylor
- School of Earth and Environmental Sciences, University of Portsmouth, Portsmouth, UK
| | - Gary R. Fones
- School of Earth and Environmental Sciences, University of Portsmouth, Portsmouth, UK
| | - Branislav Vrana
- Faculty of Science, Research Centre for Toxic Compounds in the Environment (RECETOX), Masaryk University, Brno, Czech Republic
| | - Graham A. Mills
- School of Pharmacy and Biomedical Sciences, University of Portsmouth, Portsmouth, UK
| |
Collapse
|
26
|
|
27
|
In-situ growth of zinc-aluminum-layered double hydroxide on nanoporous anodized aluminum bar for stir-bar sorptive extraction of phenolic acids. Microchem J 2019. [DOI: 10.1016/j.microc.2019.04.052] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
|
28
|
Ghorbani M, Pedramrad T, Aghamohammadhasan M, Seyedin O, Akhlaghi H, Afshar Lahoori N. Simultaneous clean-up and determination of Cu(II), Pb(II) and Cr(III) in real water and food samples using a magnetic dispersive solid phase microextraction and differential pulse voltammetry with a green and novel modified glassy carbon electrode. Microchem J 2019. [DOI: 10.1016/j.microc.2019.03.072] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
|
29
|
Ghani M, Ghoreishi SM, Shahin M, Azamati M. Zeolitic imidazole framework templated synthesis of nanoporous carbon as a coating for stir bar sorptive extraction of fluorouracil and phenobarbital in human body fluids. Microchem J 2019. [DOI: 10.1016/j.microc.2019.02.007] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|
30
|
Simultaneous HPLC-MS determination of 8-hydroxy-2'-deoxyguanosine, 3-hydroxyphenanthrene and 1-hydroxypyrene after online in-tube solid phase microextraction using a graphene oxide/poly(3,4-ethylenedioxythiophene)/polypyrrole composite. Mikrochim Acta 2019; 186:300. [PMID: 31025201 DOI: 10.1007/s00604-019-3429-2] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2018] [Accepted: 04/10/2019] [Indexed: 12/30/2022]
Abstract
The exploration of monohydroxy polycyclic aromatic hydrocarbons and 8-hydroxy-2'-deoxyguanosine (8-OHdG) produced by oxidative stress and DNA damage is a powerful and non-invasive tool to study the health risk of exposure to polycyclic aromatic hydrocarbons (PAHs). A nanocomposite prepared from graphene oxide, poly(3,4-ethylenedioxythiophene) and polypyrrole was electrodeposited on the internal surface of a stainless-steel tube for online in-tube solid phase microextraction (IT-SPME) of 8-OHdG, 3-hydroxyphenanthrene and 1-hydroxypyrene from urine. The coating possesses excellent chemical and mechanical stability, high extraction efficiency, good resistance to matrix interference, and a long lifespan. An online IT-SPME-high performance liquid chromatography-mass spectrometry method was developed for the determination of these three metabolite biomarkers in human urine. Figures of merit include (a) enrichment factors of 30-48; (b) low limits of detection (4-41 pg·mL-1 at S/N = 3); (c) wide linear ranges (0.05-50 ng·mL-1); (d) good recoveries from spiked samples (71.6-109.5%); and (e) acceptable repeatability (2.3-14.6%). The method offers the advantages of low cost, simplicity, sensitivity, rapidity and automation. Graphical abstract Schematic illustration of online in-tube solid phase microextraction using graphene oxide/poly(3,4-ethylenedioxythiophene)/polypyrrole composites as adsorbent in a stainless-steel (SS) tube for the enrichment and simultaneous determination of 8-hydroxy-2'-deoxyguanosine, 3-hydroxyphenanthrene and 1-hydroxypyrene prior to HPLC-MS analysis.
Collapse
|
31
|
Nickel-iron layered double hydroxide nanostructures for micro solid phase extraction of nonsteroidal anti-inflammatory drugs, followed by quantitation by HPLC-UV. Mikrochim Acta 2019; 186:297. [DOI: 10.1007/s00604-019-3419-4] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2018] [Accepted: 04/05/2019] [Indexed: 12/24/2022]
|
32
|
Sajid M, Khaled Nazal M, Rutkowska M, Szczepańska N, Namieśnik J, Płotka-Wasylka J. Solid Phase Microextraction: Apparatus, Sorbent Materials, and Application. Crit Rev Anal Chem 2018; 49:271-288. [DOI: 10.1080/10408347.2018.1517035] [Citation(s) in RCA: 54] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Affiliation(s)
- Muhammad Sajid
- Center for Environment and Water, Research Institute King Fahd University of Petroleum and Minerals, Dhahran, Saudi Arabia
| | - Mazen Khaled Nazal
- Center for Environment and Water, Research Institute King Fahd University of Petroleum and Minerals, Dhahran, Saudi Arabia
| | - Małgorzata Rutkowska
- Department of Analytical Chemistry, Faculty of Chemistry, Gdańsk University of Technology, Gdańsk, Poland
| | - Natalia Szczepańska
- Department of Analytical Chemistry, Faculty of Chemistry, Gdańsk University of Technology, Gdańsk, Poland
| | - Jacek Namieśnik
- Department of Analytical Chemistry, Faculty of Chemistry, Gdańsk University of Technology, Gdańsk, Poland
| | - Justyna Płotka-Wasylka
- Department of Analytical Chemistry, Faculty of Chemistry, Gdańsk University of Technology, Gdańsk, Poland
| |
Collapse
|
33
|
Chen L, Li M, Ai Y, Dang X, Huang J, Chen H. One-pot preparation of an acryloyled β-cyclodextrin-silica hybrid monolithic column and its application for determination of carbendazim and carbaryl. Food Chem 2018; 269:181-186. [DOI: 10.1016/j.foodchem.2018.07.006] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2017] [Revised: 05/10/2018] [Accepted: 07/01/2018] [Indexed: 12/26/2022]
|
34
|
Ghani M, Ghoreishi SM, Azamati M. In-situ growth of zeolitic imidazole framework-67 on nanoporous anodized aluminum bar as stir-bar sorptive extraction sorbent for determining caffeine. J Chromatogr A 2018; 1577:15-23. [DOI: 10.1016/j.chroma.2018.09.049] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2018] [Revised: 09/16/2018] [Accepted: 09/24/2018] [Indexed: 12/22/2022]
|
35
|
Zhou S, Wang H, Jin P, Wang Z, Wang X, Du X. An effective strategy for controlled fabrication and self-assembled modification of template-supported silica nanosheets on a superelastic nickel-titanium alloy fiber for highly efficient solid-phase microextraction. J Chromatogr A 2018; 1569:17-25. [DOI: 10.1016/j.chroma.2018.07.052] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2018] [Revised: 07/02/2018] [Accepted: 07/17/2018] [Indexed: 10/28/2022]
|
36
|
Kędziora-Koch K, Wasiak W. Needle-based extraction techniques with protected sorbent as powerful sample preparation tools to gas chromatographic analysis: Trends in application. J Chromatogr A 2018; 1565:1-18. [DOI: 10.1016/j.chroma.2018.06.046] [Citation(s) in RCA: 30] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2018] [Revised: 04/12/2018] [Accepted: 06/18/2018] [Indexed: 12/31/2022]
|
37
|
Zhang X, Wang P, Han Q, Li H, Wang T, Ding M. Metal-organic framework based in-syringe solid-phase extraction for the on-site sampling of polycyclic aromatic hydrocarbons from environmental water samples. J Sep Sci 2018; 41:1856-1863. [DOI: 10.1002/jssc.201701383] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2017] [Revised: 12/29/2017] [Accepted: 12/30/2017] [Indexed: 12/29/2022]
Affiliation(s)
- Xiaoqiong Zhang
- Beijing Key Laboratory of Control Technology for Toxic, Hazardous, Flammable and Explosive Sources of City; Beijing Municipal Institute of Labor Protection; Beijing P. R. China
| | - Peiyi Wang
- Beijing Key Laboratory of Control Technology for Toxic, Hazardous, Flammable and Explosive Sources of City; Beijing Municipal Institute of Labor Protection; Beijing P. R. China
| | - Qiang Han
- Key Laboratory of Bioorganic Phosphorus Chemistry and Chemical Biology; Ministry of Education; Department of Chemistry; Tsinghua University; Beijing P. R. China
| | - Hengzhen Li
- Department of Environmental Remediation; Zhongyan Technology Co. Ltd.; Beijing P. R. China
| | - Tong Wang
- Beijing Key Laboratory of Control Technology for Toxic, Hazardous, Flammable and Explosive Sources of City; Beijing Municipal Institute of Labor Protection; Beijing P. R. China
| | - Mingyu Ding
- Key Laboratory of Bioorganic Phosphorus Chemistry and Chemical Biology; Ministry of Education; Department of Chemistry; Tsinghua University; Beijing P. R. China
| |
Collapse
|
38
|
Kazantzi V, Kabir A, Furton KG, Anthemidis A. Fabric fiber sorbent extraction for on-line toxic metal determination by atomic absorption spectrometry: Determination of lead and cadmium in energy and soft drinks. Microchem J 2018. [DOI: 10.1016/j.microc.2017.11.006] [Citation(s) in RCA: 31] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
39
|
Zhou S, Wang H, Jin P, Wang Z, Wang X, Du X. Electrophoretic deposition strategy for the fabrication of highly stable functionalized silica nanoparticle coatings onto nickel-titanium alloy wires for selective solid-phase microextraction. J Sep Sci 2017; 40:4796-4804. [DOI: 10.1002/jssc.201700640] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2017] [Revised: 10/15/2017] [Accepted: 10/15/2017] [Indexed: 11/08/2022]
Affiliation(s)
- Shanshan Zhou
- College of Chemistry and Chemical Engineering; Northwest Normal University; Lanzhou P. R. China
| | - Huiju Wang
- College of Chemistry and Chemical Engineering; Northwest Normal University; Lanzhou P. R. China
| | - Panxia Jin
- College of Chemistry and Chemical Engineering; Northwest Normal University; Lanzhou P. R. China
| | - Ziyi Wang
- College of Chemistry and Chemical Engineering; Northwest Normal University; Lanzhou P. R. China
| | - Xuemei Wang
- College of Chemistry and Chemical Engineering; Northwest Normal University; Lanzhou P. R. China
| | - Xinzhen Du
- College of Chemistry and Chemical Engineering; Northwest Normal University; Lanzhou P. R. China
| |
Collapse
|
40
|
Zhang X, Niu J, Yang Y, Qin P, Tian S, Zhu J, Lu M. Fe3O4 nanoparticles as the adsorbent of magnetic solid-phase extraction for clean and preconcentration of maltol and ethyl maltol in food samples followed by HPLC analysis. J LIQ CHROMATOGR R T 2017. [DOI: 10.1080/10826076.2017.1373671] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Affiliation(s)
- Xiaoting Zhang
- Institute of Environmental and Analysis Science, School of Chemistry and Chemical Engineering, Henan University, Kaifeng, Henan, China
| | - Jiahua Niu
- Institute of Environmental and Analysis Science, School of Chemistry and Chemical Engineering, Henan University, Kaifeng, Henan, China
| | - Yixin Yang
- Institute of Environmental and Analysis Science, School of Chemistry and Chemical Engineering, Henan University, Kaifeng, Henan, China
| | - Peige Qin
- Institute of Environmental and Analysis Science, School of Chemistry and Chemical Engineering, Henan University, Kaifeng, Henan, China
| | - Shufang Tian
- Institute of Environmental and Analysis Science, School of Chemistry and Chemical Engineering, Henan University, Kaifeng, Henan, China
| | - Jinhua Zhu
- Institute of Environmental and Analysis Science, School of Chemistry and Chemical Engineering, Henan University, Kaifeng, Henan, China
| | - Minghua Lu
- Institute of Environmental and Analysis Science, School of Chemistry and Chemical Engineering, Henan University, Kaifeng, Henan, China
| |
Collapse
|
41
|
Abstract
Since the introduction in 2014 of fabric phase sorptive extraction (FPSE) as a sample preparation technique, it has attracted the attention of many scientists working in the field of separation science. This novel sorbent extraction technique has successfully utilized the benefits of sol–gel derived hybrid sorbents and a plethora of fabric substrates, resulting in a highly efficient, sensitive and green sample pretreatment methodology. The proposed procedure is an easy and efficient pathway to extract target analytes from different matrices providing inherent advantages such as high sample loading capacity and short pretreatment time. The present review mainly focuses on the background and sol–gel chemistry for the preparation of new fabric sorbents as well as on the applications of FPSE for extracting target analytes, from the time that it was first introduced. New modes of FPSE including stir FPSE, stir-bar FPSE, dynamic FPSE, and automated on-line FPSE are also highlighted and commented upon in detail. FPSE has been effectively applied for the determination of various organic and inorganic analytes in different types of environmental and biological samples in high throughput analytical, environmental, and toxicological laboratories.
Collapse
|
42
|
Liu X, Xie S, Ni T, Chen D, Wang X, Pan Y, Wang Y, Huang L, Cheng G, Qu W, Liu Z, Tao Y, Yuan Z. Magnetic solid-phase extraction based on carbon nanotubes for the determination of polyether antibiotic and s-triazine drug residues in animal food with LC-MS/MS. J Sep Sci 2017; 40:2416-2430. [DOI: 10.1002/jssc.201700017] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2017] [Revised: 03/18/2017] [Accepted: 03/27/2017] [Indexed: 12/22/2022]
Affiliation(s)
- Xiaoxing Liu
- MOA Laboratory for Risk Assessment of Quality and Safety of Livestock and Poultry Products; Wuhan Hubei China
- Hubei Collaborative Innovation Center for Animal Nutrition and Feed Safety; Huazhong Agricultural University; Wuhan Hubei China
| | - Shuyu Xie
- National Reference Laboratory of Veterinary Drug Residues (HZAU) and MAO Key Laboratory for Detection of Veterinary Drug Residues; Wuhan Hubei China
- Hubei Collaborative Innovation Center for Animal Nutrition and Feed Safety; Huazhong Agricultural University; Wuhan Hubei China
| | - Tengteng Ni
- MOA Laboratory for Risk Assessment of Quality and Safety of Livestock and Poultry Products; Wuhan Hubei China
- Hubei Collaborative Innovation Center for Animal Nutrition and Feed Safety; Huazhong Agricultural University; Wuhan Hubei China
| | - Dongmei Chen
- MOA Laboratory for Risk Assessment of Quality and Safety of Livestock and Poultry Products; Wuhan Hubei China
- Hubei Collaborative Innovation Center for Animal Nutrition and Feed Safety; Huazhong Agricultural University; Wuhan Hubei China
| | - Xu Wang
- National Reference Laboratory of Veterinary Drug Residues (HZAU) and MAO Key Laboratory for Detection of Veterinary Drug Residues; Wuhan Hubei China
| | - Yuanhu Pan
- National Reference Laboratory of Veterinary Drug Residues (HZAU) and MAO Key Laboratory for Detection of Veterinary Drug Residues; Wuhan Hubei China
| | - Yulian Wang
- MOA Laboratory for Risk Assessment of Quality and Safety of Livestock and Poultry Products; Wuhan Hubei China
- Hubei Collaborative Innovation Center for Animal Nutrition and Feed Safety; Huazhong Agricultural University; Wuhan Hubei China
| | - Lingli Huang
- National Reference Laboratory of Veterinary Drug Residues (HZAU) and MAO Key Laboratory for Detection of Veterinary Drug Residues; Wuhan Hubei China
- Hubei Collaborative Innovation Center for Animal Nutrition and Feed Safety; Huazhong Agricultural University; Wuhan Hubei China
| | - Guyue Cheng
- National Reference Laboratory of Veterinary Drug Residues (HZAU) and MAO Key Laboratory for Detection of Veterinary Drug Residues; Wuhan Hubei China
| | - Wei Qu
- National Reference Laboratory of Veterinary Drug Residues (HZAU) and MAO Key Laboratory for Detection of Veterinary Drug Residues; Wuhan Hubei China
| | - Zhenli Liu
- MOA Laboratory for Risk Assessment of Quality and Safety of Livestock and Poultry Products; Wuhan Hubei China
| | - Yanfei Tao
- MOA Laboratory for Risk Assessment of Quality and Safety of Livestock and Poultry Products; Wuhan Hubei China
- Hubei Collaborative Innovation Center for Animal Nutrition and Feed Safety; Huazhong Agricultural University; Wuhan Hubei China
| | - Zonghui Yuan
- National Reference Laboratory of Veterinary Drug Residues (HZAU) and MAO Key Laboratory for Detection of Veterinary Drug Residues; Wuhan Hubei China
- MOA Laboratory for Risk Assessment of Quality and Safety of Livestock and Poultry Products; Wuhan Hubei China
- Hubei Collaborative Innovation Center for Animal Nutrition and Feed Safety; Huazhong Agricultural University; Wuhan Hubei China
| |
Collapse
|
43
|
Ahmadi F, Sparham C, Boyacı E, Pawliszyn J. Time Weighted Average Concentration Monitoring Based on Thin Film Solid Phase Microextraction. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2017; 51:3929-3937. [PMID: 28251860 DOI: 10.1021/acs.est.6b06465] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Time weighted average (TWA) passive sampling with thin film solid phase microextraction (TF-SPME) and liquid chromatography tandem mass spectrometry (LC-MS/MS) was used for collection, identification, and quantification of benzophenone-1, benzophenone-2, benzophenone-3, benzophenone-4, 2-phenylbenzimidazole-5-sulfonic acid, octocrylene, octylmethoxycinnamate, butylmethoxydibenzoylmethane, triclocarban and triclosan in the aquatic environment. Two types of TF-SPME passive samplers, including a retracted thin film device using a hydrophilic lipophilic balance (HLB) coating, and an open bed configuration with an octadecyl silica-based (C18)coating, were evaluated in an aqueous standard generation system. Laboratory calibration results indicated that the thin film retracted device using HLB coating is suitable to determine TWA concentrations of polar analytes in water, with an uptake that was linear up to 70 days. In open bed form, a one-calibrant kinetic calibration technique was accomplished by loading benzophenone3-d5 as calibrant on the C18 coating to quantify all nonpolar compounds. The experimental results showed that the one-calibrant kinetic calibration technique can be used for determination of classes of compounds in cases where deuterated counterparts are either not available or expensive. The developed passive samplers were deployed in wastewater-dominated reaches of the Grand River (Kitchener, ON) to verify their feasibility for determination of TWA concentrations in on-site applications. Field trials results indicated that these devices are suitable for long-term and short-term monitoring of compounds varying in polarity, such as UV blockers and biocide compounds in water, and the data were in good agreement with literature data.
Collapse
Affiliation(s)
- Fardin Ahmadi
- Department of Chemistry, University of Waterloo , 200 University Avenue West, Waterloo, Ontario N2L 3G1, Canada
| | - Chris Sparham
- Unilever, Safety & Environmental Assurance Centre, Colworth Science Park, Sharnbrook, Bedford, MK44 1LQ, U.K
| | - Ezel Boyacı
- Department of Chemistry, University of Waterloo , 200 University Avenue West, Waterloo, Ontario N2L 3G1, Canada
| | - Janusz Pawliszyn
- Department of Chemistry, University of Waterloo , 200 University Avenue West, Waterloo, Ontario N2L 3G1, Canada
| |
Collapse
|
44
|
Filippou O, Bitas D, Samanidou V. Green approaches in sample preparation of bioanalytical samples prior to chromatographic analysis. J Chromatogr B Analyt Technol Biomed Life Sci 2017; 1043:44-62. [DOI: 10.1016/j.jchromb.2016.08.040] [Citation(s) in RCA: 76] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2016] [Revised: 08/21/2016] [Accepted: 08/27/2016] [Indexed: 01/07/2023]
|
45
|
Song XY, Chen J, Shi YP. Different configurations of carbon nanotubes reinforced solid-phase microextraction techniques and their applications in the environmental analysis. Trends Analyt Chem 2017. [DOI: 10.1016/j.trac.2016.11.006] [Citation(s) in RCA: 48] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
46
|
Wohde M, Bartz JO, Böhm L, Hartwig C, Keil BM, Martin K, Düring RA. Automated thin-film microextraction coupled to a flow-through cell: somewhere in between passive and active sampling. Anal Bioanal Chem 2016; 409:1975-1984. [PMID: 28012111 DOI: 10.1007/s00216-016-0145-1] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2016] [Revised: 12/01/2016] [Accepted: 12/12/2016] [Indexed: 10/20/2022]
Abstract
A prototype for the automated thin-film microextraction of pharmaceuticals from aqueous solutions has been developed and is presented here for the first time. With a software-controlled setup, extraction methods for ivermectin and iohexol have been developed. The widely used antiparasitic agent ivermectin is non-polar and has a high tendency to sorb to surfaces. In contrast to this, the nonionic but polar iodinated X-ray contrast agent iohexol is freely water soluble. With these two substances, a wide range of polarity is covered. Sorption kinetics and thermodynamics of ivermectin and iohexol were studied. With the presented passive sampling approach, it was possible to extract up to 96.2% ivermectin with a C18-phase within 1 h and up to 74.6% of iohexol with a PS-DVB phase within 36 h out of water. Using abamectin as internal standard, it was possible to quantitatively follow dissipation of ivermectin in a simulated surface water experiment. Predominantly, the newly developed prototype can be used for automated and time-resolved extraction of xenobiotics from waterbodies under field conditions, for the extraction of substances under laboratory conditions as an alternative to the elaborate solid-phase extraction, and for the automated control of chemical reaction kinetics.
Collapse
Affiliation(s)
- Manuel Wohde
- Institute of Soil Science and Soil Conservation, Justus Liebig University Giessen, IFZ, Heinrich-Buff-Ring 26-32, 35392, Giessen, Germany.
| | - Jens-Ole Bartz
- Department of Applied Microbiology, Justus Liebig University Giessen, Heinrich-Buff-Ring 26-32, 35392, Giessen, Germany
| | - Leonard Böhm
- Institute of Soil Science and Soil Conservation, Justus Liebig University Giessen, IFZ, Heinrich-Buff-Ring 26-32, 35392, Giessen, Germany
| | - Christoph Hartwig
- Institute of Soil Science and Soil Conservation, Justus Liebig University Giessen, IFZ, Heinrich-Buff-Ring 26-32, 35392, Giessen, Germany
| | - Benjamin Martin Keil
- Institute of Soil Science and Soil Conservation, Justus Liebig University Giessen, IFZ, Heinrich-Buff-Ring 26-32, 35392, Giessen, Germany
| | - Katharina Martin
- Institute of Soil Science and Soil Conservation, Justus Liebig University Giessen, IFZ, Heinrich-Buff-Ring 26-32, 35392, Giessen, Germany
| | - Rolf-Alexander Düring
- Institute of Soil Science and Soil Conservation, Justus Liebig University Giessen, IFZ, Heinrich-Buff-Ring 26-32, 35392, Giessen, Germany
| |
Collapse
|
47
|
Elmongy H, Abdel-Rehim M. Saliva as an alternative specimen to plasma for drug bioanalysis: A review. Trends Analyt Chem 2016. [DOI: 10.1016/j.trac.2016.07.010] [Citation(s) in RCA: 52] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
|
48
|
Seneviratne CA, Ghorai S, Murray KK. Laser desorption sample transfer for gas chromatography/mass spectrometry. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2016; 30:89-94. [PMID: 26661974 DOI: 10.1002/rcm.7419] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/23/2015] [Accepted: 10/06/2015] [Indexed: 06/05/2023]
Abstract
RATIONALE Ambient mass spectrometry can detect small molecules directly, but complex mixtures can be a challenge. We have developed a method that incorporates small molecule separation based on laser desorption with capture on a solid-phase microextraction (SPME) fiber for injection into a gas chromatography/mass spectrometry (GC/MS) system. METHODS Samples on a metal target were desorbed by a 3 µm mid-infrared laser focused to a 250 µm spot and 1.2 mJ pulse energy. The desorbed material was aspirated into a metal tube suspended 1 mm above the laser spot and captured on a SPME fiber. The collected material was injected into a GC/MS instrument for analysis. RESULTS We have developed a versatile approach for ambient laser desorption sampling onto SPME for GC/MS analysis. The performance of the laser desorption SPME capture GC/MS system was demonstrated for small molecule standards, a mixture of nitroaromatic explosives, and collected cigarette smoke. CONCLUSIONS The utility of ambient laser desorption sampling onto SPME for GC/MS was demonstrated. The performance of the method was evaluated by preparing calibration standards of caffeine over a range from 200 to 1000 ng. Laser desorption ambient sampling of complex mixtures was accomplished using SPME GC/MS.
Collapse
Affiliation(s)
| | - Suman Ghorai
- Department of Chemistry, Louisiana State University, Baton Rouge, LA, 70803, USA
| | - Kermit K Murray
- Department of Chemistry, Louisiana State University, Baton Rouge, LA, 70803, USA
| |
Collapse
|
49
|
Porfírio S, Gomes da Silva MD, Peixe A, Cabrita MJ, Azadi P. Current analytical methods for plant auxin quantification – A review. Anal Chim Acta 2016; 902:8-21. [DOI: 10.1016/j.aca.2015.10.035] [Citation(s) in RCA: 37] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2015] [Revised: 10/26/2015] [Accepted: 10/27/2015] [Indexed: 02/06/2023]
|
50
|
Haliński Ł, Stepnowski P. Fractionation of Cuticular Waxes from the Leaves of Solanaceae Plant Species Using Microextraction by Packed Sorbent. ACTA CHROMATOGR 2015. [DOI: 10.1556/achrom.27.2015.4.10] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|