1
|
Dong Y, Gao W, Hong S, Song D, Liu M, Du Y, Xu J, Dong F. Evaluation of Turbulence Index and Flow Pattern for Atherosclerotic Carotid Stenosis: A High-Frame-Rate Vector Flow Imaging Study. ULTRASOUND IN MEDICINE & BIOLOGY 2024; 50:549-556. [PMID: 38262885 DOI: 10.1016/j.ultrasmedbio.2023.12.019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/15/2023] [Revised: 11/29/2023] [Accepted: 12/19/2023] [Indexed: 01/25/2024]
Abstract
OBJECTIVE The emerging high-frame-rate vector flow imaging provides a new way of hemodynamic evaluation for complex blood flow. This study was aimed at exploring quantitatively the characteristics of complex flow with turbulence (Tur) index and analyzing flow patterns in atherosclerotic internal carotid artery stenosis (ICAS) using high-frame-rate vector flow imaging. METHODS This study prospectively included 60 patients with ICAS. Tur values in different segments of stenosis and cardiac phases were compared. Spearman correlation analysis was performed between clinical plaque characteristics with turbulence grading by ln(Tur). Three complex flow patterns were qualitatively drawn on vector flow mode, and the rates of detection of flow patterns in different stenosis groups and ulceration groups were compared. RESULTS Highly disordered blood flow was observed in the stenotic (Tur [M, QR] = 12.5%, 21.5%) and distal segment (15.4%, 27.2%), particularly during systole (21.0%, 30.7%, 33.3%, 38.7%, p < 0.05). Spearman correlation analysis revealed that stenosis rate was correlated with turbulence grading in the stenotic (ρ = 0.65, p < 0.05) and distal segment (ρ = 0.79, p < 0.05), and ulcer formation was correlated with turbulence grading in the stenotic segment (ρ = 0.58, p < 0.05). The overall rate of detection of three flow patterns was higher in the severe stenosis group (22/22) versus the mild to moderate stenosis group (21/38) (p < 0.001) and in the ulcer group (21/23) versus the non-ulcer group (23/37) (p < 0.001). CONCLUSION High-frame-rate vector flow imaging was helpful in assessing the severity and characteristics of flow turbulence. Lumen geometric factors could affect flow turbulence and blood flow patterns around the plaque. This would provide important hemodynamic information for the detection of high-risk plaque.
Collapse
Affiliation(s)
- Yinghui Dong
- Department of Ultrasound, Shenzhen People's Hospital, Shenzhen, Guangdong, China; Second Clinical Medical College, Jinan University, Shenzhen, Guangdong, China; First Affiliated Hospital, Southern University of Science and Technology, Shenzhen, Guangdong, China
| | - Wenjing Gao
- Department of Ultrasound, Shenzhen People's Hospital, Shenzhen, Guangdong, China; Second Clinical Medical College, Jinan University, Shenzhen, Guangdong, China; First Affiliated Hospital, Southern University of Science and Technology, Shenzhen, Guangdong, China
| | - Shaofu Hong
- Department of Ultrasound, Shenzhen People's Hospital, Shenzhen, Guangdong, China; Second Clinical Medical College, Jinan University, Shenzhen, Guangdong, China; First Affiliated Hospital, Southern University of Science and Technology, Shenzhen, Guangdong, China
| | - Di Song
- Department of Ultrasound, Shenzhen People's Hospital, Shenzhen, Guangdong, China; Second Clinical Medical College, Jinan University, Shenzhen, Guangdong, China; First Affiliated Hospital, Southern University of Science and Technology, Shenzhen, Guangdong, China
| | - Mengmeng Liu
- Department of Ultrasound, Shenzhen People's Hospital, Shenzhen, Guangdong, China; Second Clinical Medical College, Jinan University, Shenzhen, Guangdong, China; First Affiliated Hospital, Southern University of Science and Technology, Shenzhen, Guangdong, China
| | - Yigang Du
- Shenzhen Mindray Bio-Medical Electronics Company, Ltd., Shenzhen, Guangdong, China
| | - Jinfeng Xu
- Department of Ultrasound, Shenzhen People's Hospital, Shenzhen, Guangdong, China; Second Clinical Medical College, Jinan University, Shenzhen, Guangdong, China; First Affiliated Hospital, Southern University of Science and Technology, Shenzhen, Guangdong, China
| | - Fajin Dong
- Department of Ultrasound, Shenzhen People's Hospital, Shenzhen, Guangdong, China; Second Clinical Medical College, Jinan University, Shenzhen, Guangdong, China; First Affiliated Hospital, Southern University of Science and Technology, Shenzhen, Guangdong, China.
| |
Collapse
|
2
|
Haslund LE, Jorgensen LT, Bo Stuart M, Traberg MS, Jensen JA. Precise Estimation of Intravascular Pressure Gradients. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2023; 70:393-405. [PMID: 37028315 DOI: 10.1109/tuffc.2023.3255791] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/16/2023]
Abstract
This study presents a method for noninvasive pressure gradient estimation, which allows the detection of small pressure differences with higher precision compared to invasive catheters. It combines a new method for estimating the temporal acceleration of the flowing blood with the Navier-Stokes equation. The acceleration estimation is based on a double cross-correlation approach, which is hypothesized to minimize the influence of noise. Data are acquired using a 256-element, 6.5-MHz GE L3-12-D linear array transducer connected to a Verasonics research scanner. A synthetic aperture (SA) interleaved sequence with 2 ×12 virtual sources evenly distributed over the aperture and permuted in emission order is used in combination with recursive imaging. This enables a temporal resolution between correlation frames equal to the pulse repetition time at a frame rate of half the pulse repetition frequency. The accuracy of the method is evaluated against a computational fluid dynamic simulation. Here, the estimated total pressure difference complies with the CFD reference pressure difference, which yields an R -square of 0.985 and an RMSE of 3.03 Pa. The precision of the method is tested on experimental data, measured on a carotid phantom of the common carotid artery. The volume profile used during measurement was set to mimic flow in the carotid artery with a peak flow rate of 12.9 mL/s. The experimental setup showed that the measured pressure difference changes from -59.4 to 31 Pa throughout a single pulse cycle. This was estimated with a precision of 5.44% (3.22 Pa) across ten pulse cycles. The method was also compared to invasive catheter measurements in a phantom with a 60% cross-sectional area reduction. The ultrasound method detected a maximum pressure difference of 72.3 Pa with a precision of 3.3% (2.22 Pa). The catheters measured a maximum pressure difference of 105 Pa with a precision of 11.2% (11.4 Pa). This was measured over the same constriction and with a peak flow rate of 12.9 mL/s. The double cross-correlation approach revealed no improvement compared to a normal differential operator. The method's strength, thus, lies primarily in the ultrasound sequence, which allows precise and accurate velocity estimations, at which acceleration and pressure differences can be acquired.
Collapse
|
3
|
Albadawi M, Abuouf Y, Elsagheer S, Sekiguchi H, Ookawara S, Ahmed M. Influence of Rigid-Elastic Artery Wall of Carotid and Coronary Stenosis on Hemodynamics. Bioengineering (Basel) 2022; 9:708. [PMID: 36421109 PMCID: PMC9687628 DOI: 10.3390/bioengineering9110708] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2022] [Revised: 11/15/2022] [Accepted: 11/16/2022] [Indexed: 12/18/2023] Open
Abstract
Cardiovascular system abnormalities can result in serious health complications. By using the fluid-structure interaction (FSI) procedure, a comprehensive realistic approach can be employed to accurately investigate blood flow coupled with arterial wall response. The hemodynamics was investigated in both the coronary and carotid arteries based on the arterial wall response. The hemodynamics was estimated based on the numerical simulation of a comprehensive three-dimensional non-Newtonian blood flow model in elastic and rigid arteries. For stenotic right coronary artery (RCA), it was found that the maximum value of wall shear stress (WSS) for the FSI case is higher than the rigid wall. On the other hand, for the stenotic carotid artery (CA), it was found that the maximum value of WSS for the FSI case is lower than the rigid wall. Moreover, at the peak systole of the cardiac cycle (0.38 s), the maximum percentage of arterial wall deformation was found to be 1.9%. On the other hand, for the stenotic carotid artery, the maximum percentage of arterial wall deformation was found to be 0.46%. A comparison between FSI results and those obtained by rigid wall arteries is carried out. Findings indicate slight differences in results for large-diameter arteries such as the carotid artery. Accordingly, the rigid wall assumption is plausible in flow modeling for relatively large diameters such as the carotid artery. Additionally, the FSI approach is essential in flow modeling in small diameters.
Collapse
Affiliation(s)
- Muhamed Albadawi
- Department of Energy Resources Engineering, Egypt-Japan University of Science and Technology (E-JUST), P.O. Box 179, New Borg El-Arab City 5221241, Egypt
- Biomedical Flow Dynamics Laboratory, Institute of Fluid Science, Tohoku University, Sendai 980-8577, Japan
- Engineering Mathematics and Physics Department, Faculty of Engineering, Alexandria University, Alexandria 5424041, Egypt
| | - Yasser Abuouf
- Mechanical Engineering Department, Faculty of Engineering, Alexandria University, Alexandria 5424041, Egypt
| | - Samir Elsagheer
- Department of Energy Resources Engineering, Egypt-Japan University of Science and Technology (E-JUST), P.O. Box 179, New Borg El-Arab City 5221241, Egypt
- Faculty of Engineering, Aswan University, Aswan 81528, Egypt
| | - Hidetoshi Sekiguchi
- Department of Energy Resources Engineering, Egypt-Japan University of Science and Technology (E-JUST), P.O. Box 179, New Borg El-Arab City 5221241, Egypt
- Department of Chemical Engineering, Graduate School of Science and Engineering, Tokyo Institute of Technology, Ookayama, Meguro-ku, Tokyo 152-8552, Japan
| | - Shinichi Ookawara
- Department of Energy Resources Engineering, Egypt-Japan University of Science and Technology (E-JUST), P.O. Box 179, New Borg El-Arab City 5221241, Egypt
- Department of Chemical Engineering, Graduate School of Science and Engineering, Tokyo Institute of Technology, Ookayama, Meguro-ku, Tokyo 152-8552, Japan
| | - Mahmoud Ahmed
- Department of Energy Resources Engineering, Egypt-Japan University of Science and Technology (E-JUST), P.O. Box 179, New Borg El-Arab City 5221241, Egypt
- Mechanical Engineering Department, Assiut University, Assiut 71516, Egypt
| |
Collapse
|
4
|
Yazdi SG, Docherty PD, Williamson PN, Jermy M, Kabaliuk N, Khanafer A, Geoghegan PH. In vitro pulsatile flow study in compliant and rigid ascending aorta phantoms by stereo particle image velocimetry. Med Eng Phys 2021; 96:81-90. [PMID: 34565556 DOI: 10.1016/j.medengphy.2021.08.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2021] [Revised: 08/05/2021] [Accepted: 08/31/2021] [Indexed: 10/20/2022]
Abstract
The aorta is a high risk region for cardiovascular disease (CVD). Haemodynamic patterns leading to CVD are not well established despite numerous experimental and numerical studies. Most overlook effects of arterial compliance and pulsatile flow. However, rigid wall assumptions can lead to overestimation of wall shear stress; a key CVD determinant. This work investigates the effect of compliance on aortic arch haemodynamics experiencing pulsatility. Rigid and compliant phantoms of the arch and brachiocephalic branch (BCA) were manufactured. Stereoscopic particle image velocimetry was used to observe velocity fields. Higher velocity magnitude was observed in the rigid BCA during acceleration. However, during deceleration, the compliant phantom experienced higher velocity. During deceleration, a low velocity region initiated and increased in size in the BCA of both phantoms with irregular shape in the compliant. At mid-deceleration, considerably larger recirculation was observed under compliance compared to rigid. Another recirculation region formed and increased in size on the inner wall of the arch in the compliant during late deceleration, but not rigid. The recirculation regions witnessed identify as high risk areas for atherosclerosis formation by a previous ex-vivo study. The results demonstrate necessity of compliance and pulsatility in haemodynamic studies to obtain highly relevant clinical outcomes.
Collapse
Affiliation(s)
- Sina G Yazdi
- Department of Mechanical Engineering, University of Canterbury, Private Bag 4800, Christchurch, New Zealand
| | - Paul D Docherty
- Department of Mechanical Engineering, University of Canterbury, Private Bag 4800, Christchurch, New Zealand
| | - Petra N Williamson
- Department of Mechanical Engineering, University of Canterbury, Private Bag 4800, Christchurch, New Zealand
| | - Mark Jermy
- Department of Mechanical Engineering, University of Canterbury, Private Bag 4800, Christchurch, New Zealand
| | - Natalia Kabaliuk
- Department of Mechanical Engineering, University of Canterbury, Private Bag 4800, Christchurch, New Zealand
| | - Adib Khanafer
- Vascular, Endovascular, & Renal Transplant Unit Christchurch Hospital, Canterbury District Health Board, Riccarton Avenue, Christchurch 8053, New Zealand; Christchurch School of Medicine, University of Otago, New Zealand
| | - Patrick H Geoghegan
- Department of Mechanical, Biomedical and Design, College of Engineering and Physical Sciences Aston University, Birmingham, B4 7ET, England; Department of Mechanical and Industrial Engineering, University of South Africa, Johannesburg, South Africa.
| |
Collapse
|
5
|
Carvalho V, Maia I, Souza A, Ribeiro J, Costa P, Puga H, Teixeira S, Lima RA. In vitro
Biomodels in Stenotic Arteries to Perform Blood Analogues Flow Visualizations and Measurements: A Review. Open Biomed Eng J 2020. [DOI: 10.2174/1874120702014010087] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023] Open
Abstract
Cardiovascular diseases are one of the leading causes of death globally and the most common pathological process is atherosclerosis. Over the years, these cardiovascular complications have been extensively studied by applying in vivo, in vitro and numerical methods (in silico). In vivo studies represent more accurately the physiological conditions and provide the most realistic data. Nevertheless, these approaches are expensive, and it is complex to control several physiological variables. Hence, the continuous effort to find reliable alternative methods has been growing. In the last decades, numerical simulations have been widely used to assess the blood flow behavior in stenotic arteries and, consequently, providing insights into the cardiovascular disease condition, its progression and therapeutic optimization. However, it is necessary to ensure its accuracy and reliability by comparing the numerical simulations with clinical and experimental data. For this reason, with the progress of the in vitro flow measurement techniques and rapid prototyping, experimental investigation of hemodynamics has gained widespread attention. The present work reviews state-of-the-art in vitro macro-scale arterial stenotic biomodels for flow measurements, summarizing the different fabrication methods, blood analogues and highlighting advantages and limitations of the most used techniques.
Collapse
|
6
|
Hoving AM, de Vries EE, Mikhal J, de Borst GJ, Slump CH. A Systematic Review for the Design of In Vitro Flow Studies of the Carotid Artery Bifurcation. Cardiovasc Eng Technol 2020; 11:111-127. [PMID: 31823191 PMCID: PMC7082306 DOI: 10.1007/s13239-019-00448-9] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/13/2019] [Accepted: 12/02/2019] [Indexed: 12/19/2022]
Abstract
PURPOSE In vitro blood flow studies in carotid artery bifurcation models may contribute to understanding the influence of hemodynamics on carotid artery disease. However, the design of in vitro blood flow studies involves many steps and selection of imaging techniques, model materials, model design, and flow visualization parameters. Therefore, an overview of the possibilities and guidance for the design process is beneficial for researchers with less experience in flow studies. METHODS A systematic search to in vitro flow studies in carotid artery bifurcation models aiming at quantification and detailed flow visualization of blood flow dynamics results in inclusion of 42 articles. RESULTS Four categories of imaging techniques are distinguished: MRI, optical particle image velocimetry (PIV), ultrasound and miscellaneous techniques. Parameters for flow visualization are categorized into velocity, flow, shear-related, turbulent/disordered flow and other parameters. Model materials and design characteristics vary between study type. CONCLUSIONS A simplified three-step design process is proposed for better fitting and adequate match with the pertinent research question at hand and as guidance for less experienced flow study researchers. The three consecutive selection steps are: flow parameters, image modality, and model materials and designs. Model materials depend on the chosen imaging technique, whereas choice of flow parameters is independent from imaging technique and is therefore only determined by the goal of the study.
Collapse
Affiliation(s)
- A M Hoving
- University of Twente, 7500 AE, Enschede, The Netherlands.
| | - E E de Vries
- University Medical Center Utrecht, 3584 CX, Utrecht, The Netherlands
| | - J Mikhal
- University of Twente, 7500 AE, Enschede, The Netherlands
| | - G J de Borst
- University Medical Center Utrecht, 3584 CX, Utrecht, The Netherlands
| | - C H Slump
- University of Twente, 7500 AE, Enschede, The Netherlands
| |
Collapse
|
7
|
Correlation-based Doppler-angle estimation with plane-wave excitation. INFORMATICS IN MEDICINE UNLOCKED 2020. [DOI: 10.1016/j.imu.2020.100315] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
|
8
|
Yiu BYS, Chee AJY, Tang G, Luo W, Yu ACH. High frame rate doppler ultrasound bandwidth imaging for flow instability mapping. Med Phys 2019; 46:1620-1633. [PMID: 30734923 PMCID: PMC6488013 DOI: 10.1002/mp.13437] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2018] [Revised: 01/27/2019] [Accepted: 01/28/2019] [Indexed: 11/25/2022] Open
Abstract
Purpose Flow instability has been shown to contribute to the risk of future cardiovascular and cerebrovascular events. Nonetheless, it is challenging to noninvasively detect and identify flow instability in blood vessels. Here, we present a new framework called Doppler ultrasound bandwidth imaging (DUBI) that uses high‐frame‐rate ultrasound and Doppler bandwidth analysis principles to assess flow instability within an image view. Methods Doppler ultrasound bandwidth imaging seeks to estimate the instantaneous Doppler bandwidth based on autoregressive modeling at every pixel position of data frames acquired from high‐frame‐rate plane wave pulsing. This new framework is founded upon the principle that flow instability naturally gives rise to a wide range of flow velocities over a sample volume, and such velocity range in turn yields a larger Doppler bandwidth estimate. The ability for DUBI to map unstable flow was first tested over a range of fluid flow conditions (ranging from laminar to turbulent) with a nozzle‐flow phantom. As a further demonstration, DUBI was applied to assess flow instability in healthy and stenosed carotid bifurcation phantoms. Results Nozzle‐flow phantom results showed that DUBI can effectively detect and visualize the difference in Doppler bandwidth magnitude (increased from 2.1 to 5.2 kHz) at stable and unstable flow regions in an image view. Receiver operating characteristic analysis also showed that DUBI can achieve optimal sensitivity and specificity of 0.72 and 0.83, respectively. In the carotid phantom experiments, differences were observed in the spatiotemporal dynamics of Doppler bandwidth over a cardiac cycle. Specifically, as the degree of stenosis increased (from 50% to 75%), DUBI showed an increase in Doppler bandwidth magnitude from 1.4 kHz in the healthy bifurcation to 7.7 kHz at the jet tail located downstream from a 75% stenosis site, thereby indicating flow perturbation in the stenosed bifurcations. Conclusion DUBI can detect unstable flow. This new technique can provide useful hemodynamic information that may aid clinical diagnosis of atherosclerosis.
Collapse
Affiliation(s)
- Billy Y S Yiu
- Schlegel Research Institute for Aging, Department of Electrical & Computer Engineering, University of Waterloo, Waterloo, ON, N2L 3G1, Canada
| | - Adrian J Y Chee
- Schlegel Research Institute for Aging, Department of Electrical & Computer Engineering, University of Waterloo, Waterloo, ON, N2L 3G1, Canada
| | - Guo Tang
- Bioprober Corporation, Seattle, WA, 98004, USA
| | - Wenbo Luo
- Bioprober Corporation, Seattle, WA, 98004, USA
| | - Alfred C H Yu
- Schlegel Research Institute for Aging, Department of Electrical & Computer Engineering, University of Waterloo, Waterloo, ON, N2L 3G1, Canada
| |
Collapse
|
9
|
Yazdi SG, Geoghegan PH, Docherty PD, Jermy M, Khanafer A. A Review of Arterial Phantom Fabrication Methods for Flow Measurement Using PIV Techniques. Ann Biomed Eng 2018; 46:1697-1721. [DOI: 10.1007/s10439-018-2085-8] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2018] [Accepted: 06/25/2018] [Indexed: 12/21/2022]
|
10
|
Fulker D, Ene-Iordache B, Barber T. High-Resolution Computational Fluid Dynamic Simulation of Haemodialysis Cannulation in a Patient-Specific Arteriovenous Fistula. J Biomech Eng 2018; 140:2661241. [PMID: 29080304 DOI: 10.1115/1.4038289] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2017] [Indexed: 11/08/2022]
Abstract
Arteriovenous fistulae (AVF) are the preferred choice of vascular access in hemodialysis patients; however, complications such as stenosis can lead to access failure or recirculation, which reduces dialysis efficiency. This study utilized computational fluid dynamics on a patient-specific radiocephalic fistula under hemodialysis treatment to determine the dynamics of access recirculation and identify the presence of disturbed flow. Metrics of transverse wall shear stress (transWSS) and oscillatory shear index (OSI) were used to characterize the disturbed flow acting on the blood vessel wall, while a power spectral density (PSD) analysis was used to calculate the any turbulence within the access. Results showed that turbulence is generated at the anastomosis and continues through the swing segment. The arterial needle dampens the flow as blood is extracted to the dialyzer, while the venous needle reintroduces turbulence due to the presence of jet flows. Adverse shear stresses are present throughout the vascular access and coincide with these complex flow fields. The position of the needles had no effect in minimizing these forces. However, improved blood extraction may occur when the arterial needle is placed further from the anastomosis, minimizing the effects of residual turbulent structures generated at the anastomosis. Furthermore, the arterial and venous needle may be placed in close proximity to each other without increasing the risk of access recirculation, in a healthy mature fistula, due to the relatively stable blood flow in this region. This may negate the need for a long cannulation segment and aid clinicians in optimizing needle placement for hemodialysis.
Collapse
Affiliation(s)
- David Fulker
- School of Mechanical and Manufacturing Engineering, University of New South Wales, Ainsworth Building, Kensington Campus, Kensington, NSW 2025, Australia e-mail:
| | - Bogdan Ene-Iordache
- Department of Biomedical Engineering, IRCCS—Istituto di Ricerche Farmacologiche “Mario Negri,” Ranica, BG 24020, Italy e-mail:
| | - Tracie Barber
- School of Mechanical and Manufacturing Engineering, University of New South Wales, Ainsworth Building, Kensington Campus, Kensington, NSW 2025, Australia e-mail:
| |
Collapse
|
11
|
Yiu BYS, Yu ACH. Spiral Flow Phantom for Ultrasound Flow Imaging Experimentation. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2017; 64:1840-1848. [PMID: 29035216 DOI: 10.1109/tuffc.2017.2762860] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
As new ultrasound flow imaging methods are being developed, there is a growing need to devise appropriate flow phantoms that can holistically assess the accuracy of the derived flow estimates. In this paper, we present a novel spiral flow phantom design whose Archimedean spiral lumen naturally gives rise to multi-directional flow over all possible angles (i.e., from 0° to 360°). Developed using lost-core casting principles, the phantom geometry comprised a three-loop spiral (4-mm diameter and 5-mm pitch), and it was set to operate in steady flow mode (3 mL/s flow rate). After characterizing the flow pattern within the spiral vessel using computational fluid dynamics (CFD) simulations, the phantom was applied to evaluate the performance of color flow imaging (CFI) and high-frame-rate vector flow imaging. Significant spurious coloring artifacts were found when using CFI to visualize flow in the spiral phantom. In contrast, using vector flow imaging (least-squares multi-angle Doppler based on a three-transmit and three-receive configuration), we observed consistent depiction of flow velocity magnitude and direction within the spiral vessel lumen. The spiral flow phantom was also found to be a useful tool in facilitating demonstration of dynamic flow visualization based on vector projectile imaging. Overall, these results demonstrate the spiral flow phantom's practical value in analyzing the efficacy of ultrasound flow estimation methods.
Collapse
|
12
|
Goddi A, Fanizza M, Bortolotto C, Raciti MV, Fiorina I, He X, Du Y, Calliada F. Vector flow imaging techniques: An innovative ultrasonographic technique for the study of blood flow. JOURNAL OF CLINICAL ULTRASOUND : JCU 2017; 45:582-588. [PMID: 28734035 DOI: 10.1002/jcu.22519] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/02/2017] [Revised: 06/03/2017] [Accepted: 06/09/2017] [Indexed: 06/07/2023]
Abstract
Doppler ultrasonography is routinely used to identify abnormal blood flow. Nevertheless, conventional Doppler can be used to determine only the axial component of blood flow velocity and is angle dependent. A new method of multidimensional angle-independent estimation of flow velocity, called Vector Flow Imaging (VFI), has been proposed. It quantitatively evaluates the true velocity vector's amplitude and direction at any location into a vessel and displays a more intuitive depiction of the flow movements. High frame rate VFI, based on plane wave imaging, allows a detailed dynamic visualization of complex flow by showing even transient events, otherwise undetectable. © 2017 Wiley Periodicals, Inc. J Clin Ultrasound 45:582-588, 2017.
Collapse
Affiliation(s)
- Alfredo Goddi
- Centro Medico SME-Diagnostica per Immagini, Varese, Italy
| | - Marianna Fanizza
- Radiology Department, Fondazione IRCCS Policlinico San Matteo, Via Oberdan 21, Pavia, 27100, Italy
| | - Chandra Bortolotto
- Radiology Department, Fondazione IRCCS Policlinico San Matteo, Via Oberdan 21, Pavia, 27100, Italy
| | - Maria Vittoria Raciti
- Radiology Department, Fondazione IRCCS Policlinico San Matteo, Via Oberdan 21, Pavia, 27100, Italy
| | - Ilaria Fiorina
- Radiology Department, Fondazione IRCCS Policlinico San Matteo, Via Oberdan 21, Pavia, 27100, Italy
| | - Xujin He
- Ultrasound R&D Department, Shenzhen Mindray Bio-Medical Electronics Co., Ltd., Shenzhen, China
| | - Yigang Du
- Ultrasound R&D Department, Shenzhen Mindray Bio-Medical Electronics Co., Ltd., Shenzhen, China
| | - Fabrizio Calliada
- Radiology Department, Fondazione IRCCS Policlinico San Matteo, Via Oberdan 21, Pavia, 27100, Italy
| |
Collapse
|
13
|
Onaizah O, Poepping TL, Zamir M. A model of blood supply to the brain via the carotid arteries: Effects of obstructive vs. sclerotic changes. Med Eng Phys 2017; 49:121-130. [PMID: 28917828 DOI: 10.1016/j.medengphy.2017.08.009] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2016] [Revised: 05/31/2017] [Accepted: 08/18/2017] [Indexed: 10/18/2022]
Abstract
The carotid artery is one of the major supply routes of blood to the brain and a common site of vascular disease. Obstructive and sclerotic disorders within the carotid artery impact local blood flow patterns as well as overall impedance and blood supply to the brain. A lumped parameter model and an experimental in-vitro flow loop were used to study the effects of local stenosis and stiffness in the carotid artery based on a family of phantoms with different degrees of stenosis and compliance. The model also allows independent examination of the effects of downstream resistance and compliance. Mild to moderate stenosis was found to lead to minimal (∼1%) reduction in blood supply to the brain. Reduction in mean internal carotid artery (ICA) flow was statistically significant (p< 0.01) only above 70% stenosis. On the other hand, a three-fold increase in stiffness of the carotid artery, as might occur in aging, was found to lead to a modest yet statistically significant reduction (p< 0.01) in mean ICA flow. Effects of changing downstream resistance and compliance were examined. For a given pressure waveform, reduction in downstream compliance led to altered waveform shape and reduction in peak systolic flow rates where the mean flow rates were not altered. Increased downstream resistance resulted in drastic reduction in mean flow rates.
Collapse
Affiliation(s)
- O Onaizah
- Department of Medical Biophysics, The University of Western Ontario, London, Canada
| | - T L Poepping
- Department of Medical Biophysics, The University of Western Ontario, London, Canada; Department of Physics and Astronomy, The University of Western Ontario, London, Canada
| | - M Zamir
- Department of Applied Mathematics, The University of Western Ontario, London, Canada; Department of Medical Biophysics, The University of Western Ontario, London, Canada.
| |
Collapse
|
14
|
Costa PF, Albers HJ, Linssen JEA, Middelkamp HHT, van der Hout L, Passier R, van den Berg A, Malda J, van der Meer AD. Mimicking arterial thrombosis in a 3D-printed microfluidic in vitro vascular model based on computed tomography angiography data. LAB ON A CHIP 2017; 17:2785-2792. [PMID: 28717801 DOI: 10.1039/c7lc00202e] [Citation(s) in RCA: 99] [Impact Index Per Article: 14.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/19/2023]
Abstract
Arterial thrombosis is the main instigating factor of heart attacks and strokes, which result in over 14 million deaths worldwide every year. The mechanism of thrombosis involves factors from the blood and the vessel wall, and it also relies strongly on 3D vessel geometry and local blood flow patterns. Microfluidic chip-based vascular models allow controlled in vitro studies of the interaction between vessel wall and blood in thrombosis, but until now, they could not fully recapitulate the 3D geometry and blood flow patterns of real-life healthy or diseased arteries. Here we present a method for fabricating microfluidic chips containing miniaturized vascular structures that closely mimic architectures found in both healthy and stenotic blood vessels. By applying stereolithography (SLA) 3D printing of computed tomography angiography (CTA) data, 3D vessel constructs were produced with diameters of 400 μm, and resolution as low as 25 μm. The 3D-printed templates in turn were used as moulds for polydimethylsiloxane (PDMS)-based soft lithography to create microfluidic chips containing miniaturized replicates of in vivo vessel geometries. By applying computational fluid dynamics (CFD) modeling a correlation in terms of flow fields and local wall shear rate was found between the original and miniaturized artery. The walls of the microfluidic chips were coated with human umbilical vein endothelial cells (HUVECs) which formed a confluent monolayer as confirmed by confocal fluorescence microscopy. The endothelialised microfluidic devices, with healthy and stenotic geometries, were perfused with human whole blood with fluorescently labeled platelets at physiologically relevant shear rates. After 15 minutes of perfusion the healthy geometries showed no sign of thrombosis, while the stenotic geometries did induce thrombosis at and downstream of the stenotic area. Overall, the novel methodology reported here, overcomes important design limitations found in typical 2D wafer-based soft lithography microfabrication techniques and shows great potential for controlled studies of the role of 3D vessel geometries and blood flow patterns in arterial thrombosis.
Collapse
Affiliation(s)
- Pedro F Costa
- Utrecht Biofabrication Facility, Utrecht University, Uppsalalaan 8, 3584 CT Utrecht, The Netherlands
| | | | | | | | | | | | | | | | | |
Collapse
|
15
|
Pagiatakis C, Tardif JC, L'Allier PL, Mongrain R. Effect of stenosis eccentricity on the functionality of coronary bifurcation lesions-a numerical study. Med Biol Eng Comput 2017; 55:2079-2095. [PMID: 28500478 DOI: 10.1007/s11517-017-1653-7] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2016] [Accepted: 04/25/2017] [Indexed: 01/10/2023]
Abstract
Interventional cardiologists still rely heavily on angiography for the evaluation of coronary lesion severity, despite its poor correlation with the presence of ischemia. In order to improve the accuracy of the current diagnostic procedures, an understanding of the relative influence of geometric characteristics on the induction of ischemia is required. This idea is especially important for coronary bifurcation lesions (CBLs), whose treatment is complex and is associated with high rates of peri- and post-procedural clinical events. Overall, it is unclear which geometric and morphological parameters of CBLs influence the onset of ischemia. More specifically, the effect of stenosis eccentricity is unknown. Computational fluid dynamic simulations, under a geometric multiscale framework, were executed for seven CBL configurations within the left main coronary artery bifurcation. Both concentric and eccentric stenosis profiles of mild to severe constriction were considered. By using a geometric multiscale framework, the fractional flow reserve, which is the gold-standard clinical diagnostic index, could be calculated and was compared between the eccentric and concentric profiles for each case. The results suggested that for configurations where the supplying vessel is stenosed, eccentricity could have a notable effect on and therefore be an important factor that influences configuration functionality.
Collapse
Affiliation(s)
- Catherine Pagiatakis
- Department of Mechanical Engineering, McGill University, 817 Sherbrooke Street West, Montreal, Quebec, H3A 0C3, Canada. .,Montreal Heart Institute, 5000 Belanger Street, Montreal, Quebec, H1T 1C8, Canada.
| | - Jean-Claude Tardif
- Montreal Heart Institute, 5000 Belanger Street, Montreal, Quebec, H1T 1C8, Canada.,Faculty of Medicine, Université de Montréal - Pavillon Roger-Gaudry, 2900 Edouard-Montpetit Boulevard, Montreal, Quebec, H3T 1J4, Canada
| | - Philippe L L'Allier
- Montreal Heart Institute, 5000 Belanger Street, Montreal, Quebec, H1T 1C8, Canada.,Faculty of Medicine, Université de Montréal - Pavillon Roger-Gaudry, 2900 Edouard-Montpetit Boulevard, Montreal, Quebec, H3T 1J4, Canada
| | - Rosaire Mongrain
- Department of Mechanical Engineering, McGill University, 817 Sherbrooke Street West, Montreal, Quebec, H3A 0C3, Canada.,Montreal Heart Institute, 5000 Belanger Street, Montreal, Quebec, H1T 1C8, Canada
| |
Collapse
|
16
|
Sjostrand S, Widerstrom A, Ahlgren AR, Cinthio M. Design and Fabrication of a Conceptual Arterial Ultrasound Phantom Capable of Exhibiting Longitudinal Wall Movement. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2017; 64:11-18. [PMID: 27529873 DOI: 10.1109/tuffc.2016.2597246] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
The longitudinal movement of the arterial wall of large human arteries has shown promise to be an independent indicator of vascular health. Despite growing interest in this movement, its nature, causes, and implications are not fully understood, and existing phantoms have failed to show a pure longitudinal movement that is not secondary to the distension. An often overlooked aspect of the arterial wall is the interaction between the different layers. The longitudinal movement of the innermost layers, the intima and media, can be several hundred micrometers in the direction of flow during early systole. This is markedly larger than that of the adventitia, indicating that sliding occurs between the two layers. This feature was incorporated into a phantom by casting it in two parts. The molds were developed in-house using mainly a 3-D printer, a versatile and easy production method. Additionally, the phantom contains a tapered region. Using the phantom, we were able to demonstrate a pure longitudinal movement; when it was subjected to a pulsatile pressure, the wall displaced 220 [Formula: see text] (SD 40) radially and 560 [Formula: see text] (SD 74) longitudinally distal to the tapering. The motion followed the pressure variations. This paper serves as a guide for phantom production, explaining each step of the process.
Collapse
|
17
|
Chee AJY, Ho CK, Yiu BYS, Yu ACH. Walled Carotid Bifurcation Phantoms for Imaging Investigations of Vessel Wall Motion and Blood Flow Dynamics. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2016; 63:1852-1864. [PMID: 27429436 DOI: 10.1109/tuffc.2016.2591946] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
As a major application domain of vascular ultrasound, the carotid artery has long been the subject of anthropomorphic phantom design. It is nevertheless not trivial to develop walled carotid phantoms that are compatible for use in integrative imaging of carotid wall motion and flow dynamics. In this paper, we present a novel phantom design protocol that can enable efficient fabrication of walled carotid bifurcation phantoms with: (i) high acoustic compatibility, (ii) artery-like vessel elasticity, and (iii) stenotic narrowing feature. Our protocol first involved direct fabrication of the vessel core and an outer mold using computer-aided design tools and 3-D printing technology; these built parts were then used to construct an elastic vessel tube through investment casting of a polyvinyl alcohol containing mixture, and an agar-gelatin tissue mimicking slab was formed around the vessel tube. For demonstration, we applied our protocol to develop a set of healthy and stenosed (25%, 50%, 75%) carotid bifurcation phantoms. Plane wave imaging experiments were performed on these phantoms using an ultrasound scanner with channel-level configurability. Results show that the wall motion dynamics of our phantoms agreed with pulse wave propagation in an elastic vessel (pulse wave velocity of 4.67±0.71 m/s measured at the common carotid artery), and their flow dynamics matched the expected ones in healthy and stenosed bifurcation (recirculation and flow jet formation observed). Integrative imaging of vessel wall motion and blood flow dynamics in our phantoms was also demonstrated, from which we observed fluid-structure interaction differences between healthy and diseased bifurcation phantoms. These findings show that the walled bifurcation phantoms developed with our new protocol are useful in vascular imaging studies that individually or jointly assess wall motion and flow dynamics.
Collapse
|
18
|
Sousa LC, Castro CF, António CC, Sousa F, Santos R, Castro P, Azevedo E. Computational simulation of carotid stenosis and flow dynamics based on patient ultrasound data - A new tool for risk assessment and surgical planning. Adv Med Sci 2016; 61:32-9. [PMID: 26355739 DOI: 10.1016/j.advms.2015.07.009] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2014] [Revised: 06/09/2015] [Accepted: 07/24/2015] [Indexed: 10/23/2022]
Abstract
PURPOSE There is nowadays extensive experimental and computational investigation on the pathophysiology of atherosclerosis, searching correlations between its focal nature and local hemodynamic environment. The goal of this work is to present a methodology for patient-specific hemodynamics study of the carotid artery bifurcation based on the use of ultrasound (US) morphological and blood flow velocity patient data. MATERIALS/METHODS Subject-specific studies were performed for two patients, using a developed finite element code. Geometrical models were obtained from the acquisition of longitudinal and sequential cross-sectional ultrasound images and boundary conditions from Doppler velocity measurements at the common carotid artery. RESULTS There was a good agreement between ultrasound imaging data and computational simulated results. For a normal and a stenosed carotid bifurcation the velocity, wall shear stress (WSS) and WSS descriptors analysis illustrated the extremely complex hemodynamic behavior along the cardiac cycle. Different patterns were found, associated with morphology and hemodynamic patient-specific conditions. High values of time-averaged WSS (TAWSS) were found at stenosis site and for both patients TAWSS fields presented low values within areas of high oscillating shear index and relative residence time values, corresponding to recirculation zones. CONCLUSION Simulated hemodynamic parameters were able to capture the disturbed flow conditions in a normal and a stenosed carotid artery bifurcation, which play an important role in the development of local atherosclerotic plaques. Computational simulations based on clinic US might help improving diagnostic and treatment management of carotid atherosclerosis.
Collapse
|
19
|
Funamoto K, Yamashita O, Hayase T. Poly(vinyl alcohol) gel ultrasound phantom with durability and visibility of internal flow. J Med Ultrason (2001) 2015; 42:17-23. [PMID: 26578486 DOI: 10.1007/s10396-014-0560-x] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2014] [Accepted: 06/19/2014] [Indexed: 10/24/2022]
Abstract
PURPOSE Among various existing flow phantoms, none is characterized by appropriate acoustic, visibility, and durability properties simultaneously. The aim of this study was to develop a durable ultrasound phantom with visibility of the internal flow. METHODS Poly(vinyl alcohol) (PVA) gel was chosen as the basic material. The acoustic properties of various PVA gels were measured with 40-MHz ultrasound, the compositions of PVA, dimethyl sulfoxide (DMSO), and glass microbeads being changed, while visually checking the transparency. Wall-less ultrasound flow phantoms with a straight channel 2 mm in diameter were made from PVA gel, and ultrasound B-mode imaging was conducted with blood-mimicking fluid flow. RESULTS The acoustic properties of in vivo soft tissue were reproduced by PVA gel with a PVA concentration of 15 mass% and a glass microbead concentration of 2.9 mass% in a solvent of 98 mol% DMSO, showing acoustic properties of 1567 ± 4 m/s and 56 ± 5 dB/cm. The PVA gel was durable with visibility of the flow in the ultrasound phantom. The ultrasound B-mode image of the ultrasound flow phantom showed features approximating those of a mouse carotid artery. CONCLUSION A durable PVA gel ultrasound phantom with visibility of the internal flow was developed.
Collapse
Affiliation(s)
- Kenichi Funamoto
- Institute of Fluid Science, Tohoku University, 2-1-1 Katahira, Aoba-ku, Sendai, 980-8577, Japan.
| | - Osamu Yamashita
- Graduate School of Engineering, Tohoku University, 6-6-01 Aoba Aramaki, Aoba-ku, Sendai, 980-8579, Japan
| | - Toshiyuki Hayase
- Institute of Fluid Science, Tohoku University, 2-1-1 Katahira, Aoba-ku, Sendai, 980-8577, Japan
| |
Collapse
|
20
|
Ricci S, Vilkomerson D, Matera R, Tortoli P. Accurate blood peak velocity estimation using spectral models and vector doppler. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2015; 62:686-696. [PMID: 25881346 DOI: 10.1109/tuffc.2015.006982] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
Ultrasound blood peak velocity estimates are routinely used for diagnostics, such as the grading of a stenosis. The peak velocity is typically assessed from the Doppler spectrum by locating the highest frequency detectable from noise. The selected frequency is then converted to velocity by the Doppler equation. This procedure contains several potential sources of error: the frequency selection is noise dependent and sensitive to the spectral broadening, which, in turn, is affected by the Doppler angle uncertainty. The result is, often, an inaccurate estimate. In this work we propose a new method that removes the aforementioned errors. The frequency is selected by exploiting a mathematical model of the Doppler spectrum that has recently been introduced. When a very large sample volume is used, which includes all the vessel section, the model is capable of predicting the exact threshold to be used without the need of broadening compensation. The angle ambiguity is solved by applying the threshold to the Doppler spectra measured from two different directions, according to the vector Doppler technique. The proposed approach has here been validated through Field II simulations, phantom experiments, and tests on volunteers by using defocused waves to insonify a large region from a linear array probe. A mean error lower than 1% and a mean coefficient of variability lower than 5% were measured in a variety of experimental conditions.
Collapse
|
21
|
Vuong B, Genis H, Wong R, Ramjist J, Jivraj J, Farooq H, Sun C, Yang VX. Evaluation of flow velocities after carotid artery stenting through split spectrum Doppler optical coherence tomography and computational fluid dynamics modeling. BIOMEDICAL OPTICS EXPRESS 2014; 5:4405-16. [PMID: 25574447 PMCID: PMC4285614 DOI: 10.1364/boe.5.004405] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/07/2014] [Revised: 11/17/2014] [Accepted: 11/19/2014] [Indexed: 06/04/2023]
Abstract
Hemodynamics plays a critical role in the development of atherosclerosis, specifically in regions of curved vasculature such as bifurcations exhibiting irregular blood flow profiles. Carotid atherosclerotic disease can be intervened by stent implantation, but this may result in greater alterations to local blood flow and consequently further complications. This study demonstrates the use of a variant of Doppler optical coherence tomography (DOCT) known as split spectrum DOCT (ssDOCT) to evaluate hemodynamic patterns both before and after stent implantation in the bifurcation junction in the internal carotid artery (ICA). Computational fluid dynamics (CFD) models were constructed to simulate blood velocity profiles and compared to the findings achieved through ssDOCT images. Both methods demonstrated noticeable alterations in hemodynamic patterns following stent implantation, with features such as slow velocity regions at the neck of the bifurcation and recirculation zones at the stent struts. Strong correlation between CFD models and ssDOCT images demonstrate the potential of ssDOCT imaging in the optimization of stent implantation in the clinical setting.
Collapse
Affiliation(s)
- Barry Vuong
- Biophotonics and Bioengineering Laboratory, Dept. Electrical and Computer Engineering, Ryerson University, 350 Victoria Street, Toronto, ON, M5B 2K3,
Canada
| | - Helen Genis
- Biophotonics and Bioengineering Laboratory, Dept. Electrical and Computer Engineering, Ryerson University, 350 Victoria Street, Toronto, ON, M5B 2K3,
Canada
| | - Ronnie Wong
- Biophotonics and Bioengineering Laboratory, Dept. Electrical and Computer Engineering, Ryerson University, 350 Victoria Street, Toronto, ON, M5B 2K3,
Canada
| | - Joel Ramjist
- Biophotonics and Bioengineering Laboratory, Dept. Electrical and Computer Engineering, Ryerson University, 350 Victoria Street, Toronto, ON, M5B 2K3,
Canada
| | - Jamil Jivraj
- Biophotonics and Bioengineering Laboratory, Dept. Electrical and Computer Engineering, Ryerson University, 350 Victoria Street, Toronto, ON, M5B 2K3,
Canada
| | - Hamza Farooq
- Biophotonics and Bioengineering Laboratory, Dept. Electrical and Computer Engineering, Ryerson University, 350 Victoria Street, Toronto, ON, M5B 2K3,
Canada
| | - Cuiru Sun
- Biophotonics and Bioengineering Laboratory, Dept. Electrical and Computer Engineering, Ryerson University, 350 Victoria Street, Toronto, ON, M5B 2K3,
Canada
| | - Victor X.D. Yang
- Biophotonics and Bioengineering Laboratory, Dept. Electrical and Computer Engineering, Ryerson University, 350 Victoria Street, Toronto, ON, M5B 2K3,
Canada
- Physical Science - Brain Sciences Research Program, Sunnybrook Research Institute, 2075 Bayview Avenue,Toronto, ON, M4N 3M5,
Canada
- Division of Neurosurgery, Sunnybrook Health Sciences Centre, 2075 Bayview Avenue Toronto, ON, M4N 3M5,
Canada
- Division of Neurosurgery, Faculty of Medicine, University of Toronto, 1 King’s College Circle, Toronto, ON, M5S 1A8,
Canada
| |
Collapse
|
22
|
Kato T, Funamoto K, Hayase T, Sone S, Kadowaki H, Shimazaki T, Jibiki T, Miyama K, Liu L. Development and feasibility study of a two-dimensional ultrasonic-measurement-integrated blood flow analysis system for hemodynamics in carotid arteries. Med Biol Eng Comput 2014; 52:933-943. [PMID: 25192923 DOI: 10.1007/s11517-014-1193-3] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2014] [Accepted: 08/25/2014] [Indexed: 11/28/2022]
Affiliation(s)
- Takaumi Kato
- Graduate School of Biomedical Engineering, Tohoku University, Sendai, 980-8579, Japan
| | - Kenichi Funamoto
- Institute of Fluid Science, Tohoku University, 2-1-1 Katahira, Aoba-ku, Sendai, 980-8577, Japan.
| | - Toshiyuki Hayase
- Institute of Fluid Science, Tohoku University, 2-1-1 Katahira, Aoba-ku, Sendai, 980-8577, Japan
| | - Shusaku Sone
- Graduate School of Biomedical Engineering, Tohoku University, Sendai, 980-8579, Japan
| | - Hiroko Kadowaki
- Graduate School of Engineering, Tohoku University, Sendai, 980-8579, Japan
| | | | | | | | - Lei Liu
- GE Healthcare Japan, Hino, 191-8503, Japan
| |
Collapse
|
23
|
Yiu BYS, Lai SSM, Yu ACH. Vector projectile imaging: time-resolved dynamic visualization of complex flow patterns. ULTRASOUND IN MEDICINE & BIOLOGY 2014; 40:2295-309. [PMID: 24972498 DOI: 10.1016/j.ultrasmedbio.2014.03.014] [Citation(s) in RCA: 112] [Impact Index Per Article: 11.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/17/2013] [Revised: 03/02/2014] [Accepted: 03/10/2014] [Indexed: 05/22/2023]
Abstract
Achieving non-invasive, accurate and time-resolved imaging of vascular flow with spatiotemporal fluctuations is well acknowledged to be an ongoing challenge. In this article, we present a new ultrasound-based framework called vector projectile imaging (VPI) that can dynamically render complex flow patterns over an imaging view at millisecond time resolution. VPI is founded on three principles: (i) high-frame-rate broad-view data acquisition (based on steered plane wave firings); (ii) flow vector estimation derived from multi-angle Doppler analysis (coupled with data regularization and least-squares fitting); (iii) dynamic visualization of color-encoded vector projectiles (with flow speckles displayed as adjunct). Calibration results indicated that by using three transmit angles and three receive angles (-10°, 0°, +10° for both), VPI can consistently compute flow vectors in a multi-vessel phantom with three tubes positioned at different depths (1.5, 4, 6 cm), oriented at different angles (-10°, 0°, +10°) and of different sizes (dilated diameter: 2.2, 4.4 and 6.3 mm; steady flow rate: 2.5 mL/s). The practical merit of VPI was further illustrated through an anthropomorphic flow phantom investigation that considered both healthy and stenosed carotid bifurcation geometries. For the healthy bifurcation with 1.2-Hz carotid flow pulses, VPI was able to render multi-directional and spatiotemporally varying flow patterns (using a nominal frame rate of 416 fps or 2.4-ms time resolution). In the case of stenosed bifurcations (50% eccentric narrowing), VPI enabled dynamic visualization of flow jet and recirculation zones. These findings suggest that VPI holds promise as a new tool for complex flow analysis.
Collapse
Affiliation(s)
- Billy Y S Yiu
- Medical Engineering Program, University of Hong Kong, Pokfulam, Hong Kong
| | - Simon S M Lai
- Medical Engineering Program, University of Hong Kong, Pokfulam, Hong Kong
| | - Alfred C H Yu
- Medical Engineering Program, University of Hong Kong, Pokfulam, Hong Kong.
| |
Collapse
|
24
|
Kefayati S, Milner JS, Holdsworth DW, Poepping TL. In vitro shear stress measurements using particle image velocimetry in a family of carotid artery models: effect of stenosis severity, plaque eccentricity, and ulceration. PLoS One 2014; 9:e98209. [PMID: 25007248 PMCID: PMC4090132 DOI: 10.1371/journal.pone.0098209] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2013] [Accepted: 04/30/2014] [Indexed: 01/15/2023] Open
Abstract
Atherosclerotic disease, and the subsequent complications of thrombosis and plaque rupture, has been associated with local shear stress. In the diseased carotid artery, local variations in shear stress are induced by various geometrical features of the stenotic plaque. Greater stenosis severity, plaque eccentricity (symmetry) and plaque ulceration have been associated with increased risk of cerebrovascular events based on clinical trial studies. Using particle image velocimetry, the levels and patterns of shear stress (derived from both laminar and turbulent phases) were studied for a family of eight matched-geometry models incorporating independently varied plaque features - i.e. stenosis severity up to 70%, one of two forms of plaque eccentricity, and the presence of plaque ulceration). The level of laminar (ensemble-averaged) shear stress increased with increasing stenosis severity resulting in 2-16 Pa for free shear stress (FSS) and approximately double (4-36 Pa) for wall shear stress (WSS). Independent of stenosis severity, marked differences were found in the distribution and extent of shear stress between the concentric and eccentric plaque formations. The maximum WSS, found at the apex of the stenosis, decayed significantly steeper along the outer wall of an eccentric model compared to the concentric counterpart, with a 70% eccentric stenosis having 249% steeper decay coinciding with the large outer-wall recirculation zone. The presence of ulceration (in a 50% eccentric plaque) resulted in both elevated FSS and WSS levels that were sustained longer (∼20 ms) through the systolic phase compared to the non-ulcerated counterpart model, among other notable differences. Reynolds (turbulent) shear stress, elevated around the point of distal jet detachment, became prominent during the systolic deceleration phase and was widely distributed over the large recirculation zone in the eccentric stenoses.
Collapse
Affiliation(s)
- Sarah Kefayati
- Department of Physics and Astronomy, University of Western Ontario, London, ON, Canada
| | - Jaques S. Milner
- Imaging Research Laboratories, Robarts Research Institute, London, ON, Canada
| | - David W. Holdsworth
- Imaging Research Laboratories, Robarts Research Institute, London, ON, Canada
- Department of Surgery, University of Western Ontario, London, ON, Canada
| | - Tamie L. Poepping
- Department of Physics and Astronomy, University of Western Ontario, London, ON, Canada
- Imaging Research Laboratories, Robarts Research Institute, London, ON, Canada
| |
Collapse
|
25
|
Wang X, Jackson DC, Varghese T, Mitchell CC, Hermann BP, Kliewer MA, Dempsey RJ. Correlation of cognitive function with ultrasound strain indices in carotid plaque. ULTRASOUND IN MEDICINE & BIOLOGY 2014; 40:78-89. [PMID: 24120415 PMCID: PMC3849143 DOI: 10.1016/j.ultrasmedbio.2013.08.001] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/25/2013] [Revised: 07/10/2013] [Accepted: 08/01/2013] [Indexed: 05/03/2023]
Abstract
Instability in carotid vulnerable plaque can generate cerebral micro-emboli, which may be related to both stroke and eventual cognitive abnormality. Strain imaging to detect plaque vulnerability based on regions with large strain fluctuations, with arterial pulsation, may be able to determine the risk of cognitive impairment. Plaque instability may be characterized by increased strain variations over a cardiac cycle. Radiofrequency signals for ultrasound strain imaging were acquired from the carotid arteries of 24 human patients using a Siemens Antares with a VFX 13-5 linear array transducer. These patients underwent standardized cognitive assessment (Repeatable Battery for the Assessment of Neuropsychological Status [RBANS]). Plaque regions were segmented by a radiologist at end-diastole using the Medical Imaging Interaction Toolkit. A hierarchical block-matching motion tracking algorithm was used to estimate the cumulated axial, lateral and shear strains within the imaging plane. The maximum, minimum and peak-to-peak strain indices in the plaque computed from the mean cumulated strain over a small region of interest in the plaque with large deformations were obtained. The maximum and peak-to-peak mean cumulated strain indices over the entire plaque region were also computed. All strain indices were then correlated with RBANS Total performance. Overall cognitive performance (RBANS Total) was negatively associated with values of the maximum strain and the peak-to-peak for axial and lateral strains, respectively. There was no significant correlation between the RBANS Total score and shear strain and strain indices averaged over the entire identified plaque for this group of patients. However, correlation of maximum lateral strain was higher for symptomatic patients (r = -0.650, p = 0.006) than for asymptomatic patients (r = -0.115, p = 0.803). On the other hand, correlation of maximum axial strain averaged over the entire plaque region was significantly higher for asymptomatic patients (r = -0.817, p = 0.016) than for symptomatic patients (r = -0.224, p = 0.402). The results reveal a direct relationship between the maximum axial and lateral strain indices in carotid plaque and cognitive impairment.
Collapse
Affiliation(s)
- Xiao Wang
- Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin, USA
| | | | | | | | | | | | | |
Collapse
|
26
|
Wang X, Jackson D, Mitchell C, Varghese T, Hermann B, Kliewer M, Dempsey RJ. Estimation of ultrasound strain indices in carotid plaque and correlation to cognitive dysfunction. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2014; 2014:5627-30. [PMID: 25571271 PMCID: PMC4288023 DOI: 10.1109/embc.2014.6944903] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Carotid plaque prone to release emboli may be predicted by increased strain variations within plaque due to arterial pulsation over a cardiac cycle. Non-invasive ultrasound strain imaging may therefore be a viable surrogate to determine the risk of embolic stroke and possible cognitive impairment. Ultrasound strain imaging was performed on 24 human subjects with significant plaque, who also underwent standardized cognitive assessment (Repeatable Battery for the Assessment of Neuropsychological Status (RBANS)) prior to a carotid endarterectomy (CEA) procedure. Radiofrequency signals were acquired using a Siemens Antares with a VFX 13-5 linear array transducer. Plaque regions were segmented by a radiologist at end-diastole using the Medical Imaging Interaction Toolkit. A hierarchical block-matching motion tracking algorithm was utilized to estimate the cumulated axial, lateral, and shear strains within the imaging plane. The maximum strain indices of the plaque, defined as mean accumulated strain over a small region of interest in the plaque with large deformations, were obtained. All the strain indices were then correlated with RBANS Total score. Overall cognitive performance was negatively associated with maximum axial and lateral strains respectively. The results demonstrate a direct relationship between the maximum axial and lateral strain indices in carotid plaque and cognitive impairment.
Collapse
Affiliation(s)
- X Wang
- University of Wisconsin-Madison, Madison, WI 53706 USA, phone: 608-772-8929; fax: 608-262-2413
| | - D.C. Jackson
- University of Wisconsin-Madison, Madison, WI 53706 USA, phone: 608-772-8929; fax: 608-262-2413
| | - C.C. Mitchell
- Department of Biomedical Sciences, University of Wisconsin-Milwaukee, Milwaukee, WI 53201 USA
| | - T. Varghese
- University of Wisconsin-Madison, Madison, WI 53706 USA, phone: 608-772-8929; fax: 608-262-2413
| | - B.P. Hermann
- University of Wisconsin-Madison, Madison, WI 53706 USA, phone: 608-772-8929; fax: 608-262-2413
| | - M.A. Kliewer
- University of Wisconsin-Madison, Madison, WI 53706 USA, phone: 608-772-8929; fax: 608-262-2413
| | - R. J. Dempsey
- University of Wisconsin-Madison, Madison, WI 53706 USA, phone: 608-772-8929; fax: 608-262-2413
| |
Collapse
|
27
|
Kefayati S, Holdsworth DW, Poepping TL. Turbulence intensity measurements using particle image velocimetry in diseased carotid artery models: effect of stenosis severity, plaque eccentricity, and ulceration. J Biomech 2013; 47:253-63. [PMID: 24182694 DOI: 10.1016/j.jbiomech.2013.09.007] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2013] [Revised: 08/09/2013] [Accepted: 09/02/2013] [Indexed: 11/29/2022]
Abstract
Clinical decision-making for the treatment of patients with diseased carotid artery is mainly based on the severity of the stenosis. However, stenosis severity alone is not a sensitive indicator, and other local factors for the assessment of stroke risk are required. Flow disturbance is of particular interest due to its proven association with increased thromboembolic activities. The objective of this study was to investigate the level of turbulence intensity (TI) with regards to certain geometrical features of the plaque - namely stenosis severity, eccentricity, and ulceration. A family of eight carotid-artery bifurcation models was examined using particle image velocimetry. Results showed a marked difference in turbulence intensity among these models; increasing degree of stenosis severity resulted in increased turbulence intensity, going from 0.12 m/s for mild stenosis to 0.37 m/s for severe stenosis (with concentric geometry). Moreover, independent of stenosis severity, eccentricity led to further elevations in turbulence intensity, increasing TI by 0.05-0.10 m/s over the counterpart concentric plaque. The presence of ulceration (in a 50% eccentric plaque) produced a larger portion of moderate turbulence intensity (~0.10 m/s) compared to the non-ulcerated model, more proximal to the bifurcation apex in the post-stenotic recirculation zone. The effect of plaque eccentricity and ulceration in enhancing the downstream turbulence has potential clinical implications for a more sensitive assessment of stroke risk beyond stenosis severity alone.
Collapse
Affiliation(s)
- Sarah Kefayati
- Department of Physics and Astronomy, University of Western Ontario, 1151 Richmond Street, London, ON N6A 3K7, Canada
| | - David W Holdsworth
- Department of Surgery, University of Western Ontario, London, ON, Canada; Imaging Research Laboratories, Robarts Research Institute, London, ON, Canada
| | - Tamie L Poepping
- Department of Physics and Astronomy, University of Western Ontario, 1151 Richmond Street, London, ON N6A 3K7, Canada; Imaging Research Laboratories, Robarts Research Institute, London, ON, Canada.
| |
Collapse
|
28
|
Lai SSM, Yiu BYS, Poon AKK, Yu ACH. Design of anthropomorphic flow phantoms based on rapid prototyping of compliant vessel geometries. ULTRASOUND IN MEDICINE & BIOLOGY 2013; 39:1654-1664. [PMID: 23791354 DOI: 10.1016/j.ultrasmedbio.2013.03.015] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/29/2012] [Revised: 02/25/2013] [Accepted: 03/09/2013] [Indexed: 06/02/2023]
Abstract
Anatomically realistic flow phantoms are essential experimental tools for vascular ultrasound. Here we describe how these flow phantoms can be efficiently developed via a rapid prototyping (RP) framework that involves direct fabrication of compliant vessel geometries. In this framework, anthropomorphic vessel models were drafted in computer-aided design software, and they were fabricated using stereolithography (one type of RP). To produce elastic vessels, a compliant photopolymer was used for stereolithography. We fabricated a series of compliant, diseased carotid bifurcation models with eccentric stenosis (50%) and plaque ulceration (types I and III), and they were used to form thin-walled flow phantoms by coupling the vessels to an agar-based tissue-mimicking material. These phantoms were found to yield Doppler spectrograms with significant spectral broadening and color flow images with mosaic patterns, as typical of disturbed flow under stenosed and ulcerated disease conditions. Also, their wall distension behavior was found to be similar to that observed in vivo, and this corresponded with the vessel wall's average elastic modulus (391 kPa), which was within the nominal range for human arteries. The vessel material's acoustic properties were found to be sub-optimal: the estimated average acoustic speed was 1801 m/s, and the attenuation coefficient was 1.58 dB/(mm·MHz(n)) with a power-law coefficient of 0.97. Such an acoustic mismatch nevertheless did not notably affect our Doppler spectrograms and color flow image results. These findings suggest that phantoms produced from our design framework have the potential to serve as ultrasound-compatible test beds that can simulate complex flow dynamics similar to those observed in real vasculature.
Collapse
Affiliation(s)
- Simon S M Lai
- Medical Engineering Program, University of Hong Kong, Pokfulam, Hong Kong SAR, China
| | | | | | | |
Collapse
|
29
|
Simulation of a pulsatile non-Newtonian flow past a stenosed 2D artery with atherosclerosis. Comput Biol Med 2013; 43:1098-113. [PMID: 23930803 DOI: 10.1016/j.compbiomed.2013.05.023] [Citation(s) in RCA: 51] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2013] [Revised: 05/02/2013] [Accepted: 05/29/2013] [Indexed: 12/31/2022]
Abstract
Atherosclerotic plaque can cause severe stenosis in the artery lumen. Blood flow through a substantially narrowed artery may have different flow characteristics and produce different forces acting on the plaque surface and artery wall. The disturbed flow and force fields in the lumen may have serious implications on vascular endothelial cells, smooth muscle cells, and circulating blood cells. In this work a simplified model is used to simulate a pulsatile non-Newtonian blood flow past a stenosed artery caused by atherosclerotic plaques of different severity. The focus is on a systematic parameter study of the effects of plaque size/geometry, flow Reynolds number, shear-rate dependent viscosity and flow pulsatility on the fluid wall shear stress and its gradient, fluid wall normal stress, and flow shear rate. The computational results obtained from this idealized model may shed light on the flow and force characteristics of more realistic blood flow through an atherosclerotic vessel.
Collapse
|
30
|
Yiu BYS, Yu ACH. High-frame-rate ultrasound color-encoded speckle imaging of complex flow dynamics. ULTRASOUND IN MEDICINE & BIOLOGY 2013; 39:1015-25. [PMID: 23511009 DOI: 10.1016/j.ultrasmedbio.2012.12.016] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/05/2012] [Revised: 11/04/2012] [Accepted: 12/23/2012] [Indexed: 05/15/2023]
Abstract
Realization of flow imaging at high frame rates is essential to the visualization of complex flow patterns with fast-changing spatiotemporal dynamics. In this study, we present an experimental demonstration of a novel ultrasound-based high-frame-rate flow visualization technique called color-encoded speckle imaging (CESI), which depicts flow information in a hybrid form comprising flow speckle pattern and color-encoded velocity mapping. This technique works by integrating two key principles: (i) using broad-view data acquisition schemes like plane wave compounding to obtain image data at frame rates well beyond the video display range and (ii) deriving and displaying both flow speckles and velocity estimates from the acquired broad-view image data. CESI was realized on a channel-domain ultrasound imaging research platform, and its performance was evaluated in the context of monitoring complex flow dynamics inside a carotid bifurcation flow phantom with 25% eccentric stenosis at the inlet of the internal carotid artery. Results show that, using an imaging frame rate of 2000 frames per second (based on plane wave compounding with five steering angles), CESI can effectively render flow acceleration and deceleration with visual continuity. It is also effective in depicting how stenosis-related flow disturbance events, such as flow jet formation and post-stenotic flow recirculation, evolve spatiotemporally over a pulse cycle. We anticipate that CESI can represent a rational approach to rendering flow information in ultrasound-based vascular diagnoses.
Collapse
Affiliation(s)
- Billy Y S Yiu
- Medical Engineering Program, The University of Hong Kong, Pokfulam, Hong Kong
| | | |
Collapse
|
31
|
Javadzadegan A, Yong ASC, Chang M, Ng ACC, Yiannikas J, Ng MKC, Behnia M, Kritharides L. Flow recirculation zone length and shear rate are differentially affected by stenosis severity in human coronary arteries. Am J Physiol Heart Circ Physiol 2013; 304:H559-66. [DOI: 10.1152/ajpheart.00428.2012] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Flow recirculation zones and shear rate are associated with distinct pathogenic biological pathways relevant to thrombosis and atherogenesis. The interaction between stenosis severity and lesion eccentricity in determining the length of flow recirculation zones and peak shear rate in human coronary arteries in vivo is unclear. Computational fluid dynamic simulations were performed under resting and hyperemic conditions on computer-generated models and three-dimensional (3-D) reconstructions of coronary arteriograms of 25 patients. Boundary conditions for 3-D reconstructions simulations were obtained by direct measurements using a pressure-temperature sensor guidewire. In the computer-generated models, stenosis severity and lesion eccentricity were strongly associated with recirculation zone length and maximum shear rate. In the 3-D reconstructions, eccentricity increased recirculation zone length and shear rate when lesions of the same stenosis severity were compared. However, across the whole population of coronary lesions, eccentricity did not correlate with recirculation zone length or shear rate ( P = not signficant for both), whereas stenosis severity correlated strongly with both parameters ( r = 0.97, P < 0.001, and r = 0.96, P < 0.001, respectively). Nonlinear regression analyses demonstrated that the relationship between stenosis severity and peak shear was exponential, whereas the relationship between stenosis severity and recirculation zone length was sigmoidal, with an apparent threshold effect, demonstrating a steep increase in recirculation zone length between 40% and 60% diameter stenosis. Increasing stenosis severity and lesion eccentricity can both increase flow recirculation and shear rate in human coronary arteries. Flow recirculation is much more sensitive to mild changes in the severity of intermediate stenoses than is peak shear.
Collapse
Affiliation(s)
- Ashkan Javadzadegan
- Department of Mechanical Engineering, University of Sydney, Sydney, New South Wales, Australia
| | - Andy S. C. Yong
- Department of Cardiology, Concord Hospital, University of Sydney, Sydney, New South Wales, Australia; and
| | - Michael Chang
- Department of Cardiology, Concord Hospital, University of Sydney, Sydney, New South Wales, Australia; and
| | - Austin C. C. Ng
- Department of Cardiology, Concord Hospital, University of Sydney, Sydney, New South Wales, Australia; and
| | - John Yiannikas
- Department of Cardiology, Concord Hospital, University of Sydney, Sydney, New South Wales, Australia; and
| | - Martin K. C. Ng
- Department of Cardiology, Royal Prince Alfred Hospital, University of Sydney, Sydney, New South Wales, Australia
| | - Masud Behnia
- Department of Mechanical Engineering, University of Sydney, Sydney, New South Wales, Australia
| | - Leonard Kritharides
- Department of Cardiology, Concord Hospital, University of Sydney, Sydney, New South Wales, Australia; and
| |
Collapse
|
32
|
Transitional flow analysis in the carotid artery bifurcation by proper orthogonal decomposition and particle image velocimetry. Med Eng Phys 2012; 35:898-909. [PMID: 23025907 DOI: 10.1016/j.medengphy.2012.08.020] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2012] [Revised: 08/22/2012] [Accepted: 08/28/2012] [Indexed: 11/23/2022]
Abstract
Blood flow instabilities in the carotid artery bifurcation have been highly correlated to clot formation and mobilization resulting in ischemic stroke. In this work, PIV-measured flow velocities in normal and stenosed carotid artery bifurcation models were analyzed by means of proper orthogonal decomposition (POD). Through POD analysis, transition to more complex flow was visualized and quantified for increasing stenosis severity. While no evidence of transitional flow was seen in the normal model, the 50%-stenosed model started to show characteristics of transitional flow, which became highly evident in the 70% model, with greatest manifestation during the systolic phase of the cardiac cycle. By means of a model comparison, we demonstrate two quantitative measures of the flow complexity through the power-law decay slope of the energy spectrum and the global entropy. The more complex flow in the 70%-stenosed model showed a flatter slope of energy decay (-0.91 compared to -1.34 for 50% stenosis) and higher entropy values (0.26 compared to 0.17). Finally, the minimum temporal resolution required for POD analysis of carotid artery flow was found to be 100 Hz when determined through a more typical energy-mode convergence test, as compared to 400 Hz based on global entropy values.
Collapse
|
33
|
Kefayati S, Poepping TL. 3-D flow characterization and shear stress in a stenosed carotid artery bifurcation model using stereoscopic PIV technique. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2010; 2010:3386-9. [PMID: 21097242 DOI: 10.1109/iembs.2010.5627933] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
The carotid artery bifurcation is a common site of atherosclerosis which is a major leading cause of ischemic stroke. The impact of stenosis in the atherosclerotic carotid artery is to disturb the flow pattern and produce regions with high shear rate, turbulence, and recirculation, which are key hemodynamic factors associated with plaque rupture, clot formation, and embolism. In order to characterize the disturbed flow in the stenosed carotid artery, stereoscopic PIV measurements were performed in a transparent model with 50% stenosis under pulsatile flow conditions. Simulated ECG gating of the flowrate waveform provides external triggering required for volumetric reconstruction of the complex flow patterns. Based on the three-component velocity data in the lumen region, volumetric shear-stress patterns were derived.
Collapse
Affiliation(s)
- Sarah Kefayati
- Department of Physics and Astronomy, the University of Western Ontario, London, N6A 3K7 Canada.
| | | |
Collapse
|