1
|
Mohammed MK, Alahmari A, Alkhalefah H, Abidi MH. Evaluation of zirconia ceramics fabricated through DLP 3d printing process for dental applications. Heliyon 2024; 10:e36725. [PMID: 39263110 PMCID: PMC11386276 DOI: 10.1016/j.heliyon.2024.e36725] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2024] [Revised: 08/20/2024] [Accepted: 08/21/2024] [Indexed: 09/13/2024] Open
Abstract
Zirconia ceramics are versatile materials with remarkable properties such as a high thermal resistance, high fracture strength, and low thermal conductivity. They are chemically inert and highly wear- and corrosion-resistant, making them ideal for a wide range of applications in the aerospace, automotive, and biomedical fields. In dentistry, zirconia ceramics are used for veneers, crowns, bridges, and implants because of their biocompatibility. Despite the various benefits of zirconia ceramics, they are difficult to process because of their high hardness and brittleness. Additive manufacturing (AM) has proven to be a viable alternative to conventional fabrication processes, particularly for the processing of difficult-to-cut materials. AM of ceramics has gained significant attention in recent years because of its flexibility and ability to produce customized geometries rapidly and economically. In this study, the digital light processing (DLP) technique was employed to 3D print yttria-stabilized zirconia. The fabricated zirconia was evaluated and characterized for use in dental applications. Thermogravimetric analysis (TGA) and differential thermogravimetry (DTG) were performed on the green body to assess the decomposition of the additives in the slurry and determine the debinding temperatures. The as-built parts were subjected to debinding and sintering to obtain fully dense zirconia parts. The parts tended to shrink after sintering; therefore, the shrinkage ratios were evaluated and found to be 1.2817, 1.2900, and 1.3388 in the x-, y-, and z-directions, respectively. The average density after sintering was 6.031 g/cc. The flexural strength determined using four-point bending tests was 451.876 MPa, and the tensile and compressive strengths were 143 MPa and 298.4 MPa, respectively.
Collapse
Affiliation(s)
- Muneer Khan Mohammed
- Advanced Manufacturing Institute, King Saud University, PO Box 800, Riyadh, 11421, Saudi Arabia
| | - Abdulrahman Alahmari
- Industrial Engineering Department, King Saud University, PO Box 800, Riyadh, 11421, Saudi Arabia
| | - Hisham Alkhalefah
- Advanced Manufacturing Institute, King Saud University, PO Box 800, Riyadh, 11421, Saudi Arabia
| | - Mustufa Haider Abidi
- Advanced Manufacturing Institute, King Saud University, PO Box 800, Riyadh, 11421, Saudi Arabia
| |
Collapse
|
2
|
Vierling L, Liu CC, Wiedemeier D, Gubler A, Schmidlin PR. Assessing the Impact of Various Decontamination Instruments on Titanium and Zirconia Dental Implants: An In Vitro Study. Dent J (Basel) 2024; 12:136. [PMID: 38786534 PMCID: PMC11119916 DOI: 10.3390/dj12050136] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2024] [Revised: 04/29/2024] [Accepted: 05/07/2024] [Indexed: 05/25/2024] Open
Abstract
This study investigates the impact of various instrumentation techniques on material removal and surface changes in titanium (Ti)- and zirconia (Zr) implant discs. Ti- and Zr discs were subjected to standardized experiments using various instruments including airflow, ultrasound, carbide, and diamond burs. Instrumentation was performed for 60 s with continuous automatic motion. Abrasion and changes in surface roughness were assessed using profilometry, while scanning electron microscopy was used to examine morphological changes and particle size. Carbide burs predominantly caused abrasion on Ti discs, while diamond burs caused more abrasion on Zr discs. The Ti discs were more susceptible to surface changes. However, among the materials tested, machined Zr discs treated with diamond burs produced the largest particle. In certain cases, a statistical significance (p < 0.05) was observed between the groups, while in others, there was no considerable difference among the means (p > 0.05). These results highlighted the statistical significance of our findings. These results found diverse alterations in surface characteristics of Ti- and Zr discs due to different instruments, with carbide and diamond burs causing notable effects. The findings highlight the need for a careful balance between promoting healing and minimizing harm during implantoplasty.
Collapse
Affiliation(s)
- Louisa Vierling
- Clinic of Conservative and Preventive Dentistry, Division of Periodontology and Peri-Implant Diseases, Center of Dental Medicine, University of Zurich, 8032 Zurich, Switzerland; (L.V.); (C.C.L.); (A.G.)
| | - Chun Ching Liu
- Clinic of Conservative and Preventive Dentistry, Division of Periodontology and Peri-Implant Diseases, Center of Dental Medicine, University of Zurich, 8032 Zurich, Switzerland; (L.V.); (C.C.L.); (A.G.)
| | - Daniel Wiedemeier
- Statistics Group, Center of Dental Medicine, University of Zurich, 8032 Zurich, Switzerland;
| | - Andrea Gubler
- Clinic of Conservative and Preventive Dentistry, Division of Periodontology and Peri-Implant Diseases, Center of Dental Medicine, University of Zurich, 8032 Zurich, Switzerland; (L.V.); (C.C.L.); (A.G.)
| | - Patrick R. Schmidlin
- Clinic of Conservative and Preventive Dentistry, Division of Periodontology and Peri-Implant Diseases, Center of Dental Medicine, University of Zurich, 8032 Zurich, Switzerland; (L.V.); (C.C.L.); (A.G.)
| |
Collapse
|
3
|
Kongkiatkamon S, Rokaya D, Kengtanyakich S, Peampring C. Current classification of zirconia in dentistry: an updated review. PeerJ 2023; 11:e15669. [PMID: 37465158 PMCID: PMC10351515 DOI: 10.7717/peerj.15669] [Citation(s) in RCA: 13] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2023] [Accepted: 06/09/2023] [Indexed: 07/20/2023] Open
Abstract
Zirconia, a crystalline oxide of zirconium, holds good mechanical, optical, and biological properties. The metal-free restorations, mostly consisting of all-ceramic/zirconia restorations, are becoming popular restorative materials in restorative and prosthetic dentistry choices for aesthetic and biological reasons. Dental zirconia has increased over the past years producing wide varieties of zirconia for prosthetic restorations in dentistry. At present, literature is lacking on the recent zirconia biomaterials in dentistry. Currently, no article has the latest information on the various zirconia biomaterials in dentistry. Hence, the aim of this article is to present an overview of recent dental zirconia biomaterials and tends to classify the recent zirconia biomaterials in dentistry. This article is useful for dentists, dental technicians, prosthodontists, academicians, and researchers in the field of dental zirconia.
Collapse
Affiliation(s)
- Suchada Kongkiatkamon
- Department of Prosthetic Dentistry, Faculty of Dentistry, Prince of Songkla University, Songkhla, Thailand
| | - Dinesh Rokaya
- Faculty of Dentistry, Zarqa University, Zarqa, Jordan
| | - Santiphab Kengtanyakich
- Prosthodontic Section, Department of Restorative Dentistry, Naresuan University, Phitsanulok, Thailand
| | - Chaimongkon Peampring
- Department of Prosthetic Dentistry, Faculty of Dentistry, Prince of Songkla University, Songkhla, Thailand
| |
Collapse
|
4
|
Porporati AA, Mödinger Y, Fischer S, Polajžer S, Mettang M, Deisinger U, Podlogar M, Trebše R, Lovšin N. Zirconia-Toughened Alumina Ceramic Wear Particles Do Not Elicit Inflammatory Responses in Human Macrophages. Int J Mol Sci 2023; 24:6482. [PMID: 37047454 PMCID: PMC10095128 DOI: 10.3390/ijms24076482] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2023] [Revised: 03/24/2023] [Accepted: 03/29/2023] [Indexed: 04/14/2023] Open
Abstract
Ten percent of patients undergoing total hip arthroplasty (THA) require revision surgery. One of the reasons for THA are wear particles released from the implants that can activate the immune defense and cause osteolysis and failure of the joint implant. The discrepancies between reports on toxicity and immunogenicity of the implant materials led us to this study in which we compared toxicity and immunogenicity of well-defined nanoparticles from Al2O3, zirconia-toughened alumina (ZTA), and cobalt chrome (CoCr), a human THP-1 macrophage cell line, human PBMCs, and therefrom-derived primary macrophages. None of the tested materials decreased the viability of THP-1 macrophages nor human primary macrophages at the 24 h time point, indicating that at concentrations from 0.05 to 50 µm3/cell the tested materials are non-toxic. Forty-eight hours of treatment of THP-1 macrophages with 5 µm3/cell of CoCr and Al2O3 caused 8.3-fold and 4.6-fold increases in TNF-α excretion, respectively, which was not observed for ZTA. The comparison between THP-1 macrophages and human primary macrophages revealed that THP-1 macrophages show higher activation of cytokine expression in the presence of CoCr and Al2O3 particles than primary macrophages. Our results indicate that ZTA is a non-toxic implant material with no immunogenic effects in vitro.
Collapse
Affiliation(s)
- Alessandro Alan Porporati
- Medical Products Division, CeramTec GmbH, 73207 Plochingen, Germany; (A.A.P.); (Y.M.); (M.M.); (U.D.)
- Department of Engineering and Architecture, University of Trieste, 34127 Trieste, Italy
| | - Yvonne Mödinger
- Medical Products Division, CeramTec GmbH, 73207 Plochingen, Germany; (A.A.P.); (Y.M.); (M.M.); (U.D.)
| | - Sarah Fischer
- Medizintechnik, University of Stuttgart, 70174 Stuttgart, Germany
| | - Sara Polajžer
- Faculty of Pharmacy, University of Ljubljana, Aškerčeva 7, 1000 Ljubljana, Slovenia
| | - Melanie Mettang
- Medical Products Division, CeramTec GmbH, 73207 Plochingen, Germany; (A.A.P.); (Y.M.); (M.M.); (U.D.)
| | - Ulrike Deisinger
- Medical Products Division, CeramTec GmbH, 73207 Plochingen, Germany; (A.A.P.); (Y.M.); (M.M.); (U.D.)
| | | | - Rihard Trebše
- Valdoltra Orthopaedic Hospital, 6280 Ankaran, Slovenia;
- Faculty of Medicine, University of Ljubljana, Vrazov trg 2, 1000 Ljubljana, Slovenia
| | - Nika Lovšin
- Faculty of Pharmacy, University of Ljubljana, Aškerčeva 7, 1000 Ljubljana, Slovenia
| |
Collapse
|
5
|
Glauser R, Schupbach P. Early bone formation around immediately placed two-piece tissue-level zirconia implants with a modified surface: an experimental study in the miniature pig mandible. Int J Implant Dent 2022; 8:37. [PMID: 36103094 PMCID: PMC9474793 DOI: 10.1186/s40729-022-00437-z] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2022] [Accepted: 09/08/2022] [Indexed: 11/11/2022] Open
Abstract
PURPOSE To histologically examine early bone formation around transmucosal implants and to evaluate the influence of surface characteristics on early peri-implant bone healing using a miniature pig model. For this, commercially available dental implants with a rough zirconia (YTZP) surface were compared to surface-modified Ti control implants at 4 and 8 weeks after placement. METHODS Immediately following the extraction of six mandibular premolars, 20 two-piece, tissue-level, screw-shaped YTZP implants (Patent™ Standard Zirconia Implant ø4.1 × 11 mm) with a modified rough blasted before sintering surface were inserted in four adult miniature pigs. In addition, four titanium (Ti) tissue-level implants (Straumann® Standard RN ø4.1 × 10 mm Roxolid®) with a moderate surface (SLActive®), one per animal, were placed as control implants. A histological analysis was performed on the hard tissues after 4 and 8 weeks of transmucosal healing. RESULTS The results show a high rate of osseointegration of the test YTZP dental implants at 4 and 8 weeks following insertion. At 4 weeks, a bone-to-implant contact ratio (BIC) of 73.7% (SD ± 16.8) for the test implants (n = 10) and 58.5% for the first control implant was achieved. The second control implant had to be excluded from analysis. At 8 weeks, a BIC of 82.4% (SD ± 16.9) for the test implants (n = 9) and 93.6% (SD ± 9.1) (n = 2) for the control implant was achieved. No statistical difference was observed comparing 4 and 8 weeks YTZP data (p = 0.126). CONCLUSIONS The results indicate a predictable osseointegration of immediate zirconia implants with a modified YTZP implant surface and a high degree of BIC present at 4 weeks following insertion. After 8 weeks of healing both the zirconia implants and the Ti implants show a BIC indicating full osseointegration. Further studies involving a larger sample size with more time points are needed to confirm these results.
Collapse
Affiliation(s)
| | - Peter Schupbach
- Schupbach Ltd, Histology and Electron Microscopy, Thalwil, Switzerland.
| |
Collapse
|
6
|
Are additional screws required for press-fit fixation of cementless acetabular cups? A systematic review and meta-analysis. J Orthop Traumatol 2022; 23:9. [PMID: 35142933 PMCID: PMC8831679 DOI: 10.1186/s10195-022-00629-8] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/10/2021] [Accepted: 01/25/2022] [Indexed: 01/10/2023] Open
Abstract
Background Press-fit cementless acetabular cup is widely used in total hip arthroplasty (THA). However, the use of additional screws for the acetabular cup has been extensively debated. The purpose of this review is to compare the stability, revision rate, wear rate, and clinical scores of cementless acetabular cups with and without screws in THA. Materials and Methods Comprehensive literature searches of the following databases were performed: Cochrane Library, Pubmed, Web of Science, OVID, Elsevier ClinicalKey, Clinicaltrials.gov, and EMBASE. We searched for trials that compared cementless acetabular cups with screws or without screws, and were published in the English language. We evaluated the stability of the prosthesis by osteolysis and migration. The clinical scores included Harris hip scores (HHS) and pain scores. Results Nineteen articles involving 4046 THAs met the inclusion criteria. Our analysis revealed that additional screws did not increase the stability of acetabular cups, and there was no statistical significance between the groups with and without screws in osteolysis and clinically relevant migration. Revision rates showed no significant difference between the groups with and without screws. There was no difference in wear between the two groups. Our analysis showed no difference in pain scores and HHS between groups. Conclusion Press-fit without screws could achieve sufficient acetabular cup stability. Acetabular cups without screws showed no difference from acetabular cups with screws in many outcomes. Additional screws are not required for cementless acetabular cups. Level of evidence: Level III.
Collapse
|
7
|
Ban S. Classification and Properties of Dental Zirconia as Implant Fixtures and Superstructures. MATERIALS 2021; 14:ma14174879. [PMID: 34500970 PMCID: PMC8432657 DOI: 10.3390/ma14174879] [Citation(s) in RCA: 22] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/26/2021] [Revised: 08/16/2021] [Accepted: 08/24/2021] [Indexed: 11/16/2022]
Abstract
Various types of zirconia are widely used for the fabrication of dental implant superstructures and fixtures. Zirconia-alumina composites, such as ATZ and NanoZR, are adequate for implant fixtures because they have excellent mechanical strength in spite of insufficient esthetic properties. On the other hand, yttria-stabilized zirconia has been used for implant superstructures because of sufficient esthetic properties. They are classified to 12 types with yttria content, monochromatic/polychromatic, uniform/hybrid composition, and monolayer/multilayer. Zirconia with a higher yttria content has higher translucency and lower mechanical strength. Fracture strength of superstructures strongly depends on the strength on the occlusal contact region. It suggests that adequate zirconia should be selected as the superstructure crown, depending on whether strength or esthetics is prioritized. Low temperature degradation of zirconia decreases with yttria content, but even 3Y zirconia has a sufficient durability in oral condition. Although zirconia is the hardest dental materials, zirconia restorative rarely subjects the antagonist teeth to occlusal wear when it is mirror polished. Furthermore, zirconia has less bacterial adhesion and better soft tissue adhesion when it is mirror polished. This indicates that zirconia has advantageous for implant superstructures. As implant fixtures, zirconia is required for surface modification to obtain osseointegration to bone. Various surface treatments, such as roughening, surface activation, and coating, has been developed and improved. It is concluded that an adequately selected zirconia is a suitable material as implant superstructures and fixtures because of mechanically, esthetically, and biologically excellent properties.
Collapse
Affiliation(s)
- Seiji Ban
- Department of Dental Materials Science, School of Dentistry, Aichi Gakuin University, Nagoya 464-8650, Japan
| |
Collapse
|
8
|
Revealing Inflammatory Indications Induced by Titanium Alloy Wear Debris in Periprosthetic Tissue by Label-Free Correlative High-Resolution Ion, Electron and Optical Microspectroscopy. MATERIALS 2021; 14:ma14113048. [PMID: 34205030 PMCID: PMC8199876 DOI: 10.3390/ma14113048] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/30/2021] [Revised: 05/25/2021] [Accepted: 05/31/2021] [Indexed: 01/14/2023]
Abstract
The metallic-associated adverse local tissue reactions (ALTR) and events accompanying worn-broken implant materials are still poorly understood on the subcellular and molecular level. Current immunohistochemical techniques lack spatial resolution and chemical sensitivity to investigate causal relations between material and biological response on submicron and even nanoscale. In our study, new insights of titanium alloy debris-tissue interaction were revealed by the implementation of label-free high-resolution correlative microscopy approaches. We have successfully characterized its chemical and biological impact on the periprosthetic tissue obtained at revision surgery of a fractured titanium-alloy modular neck of a patient with hip osteoarthritis. We applied a combination of photon, electron and ion beam micro-spectroscopy techniques, including hybrid optical fluorescence and reflectance micro-spectroscopy, scanning electron microscopy (SEM), Energy-dispersive X-ray Spectroscopy (EDS), helium ion microscopy (HIM) and micro-particle-induced X-ray emission (micro-PIXE). Micron-sized wear debris were found as the main cause of the tissue oxidative stress exhibited through lipopigments accumulation in the nearby lysosome. This may explain the indications of chronic inflammation from prior histologic examination. Furthermore, insights on extensive fretting and corrosion of the debris on nm scale and a quantitative measure of significant Al and V release into the tissue together with hydroxyapatite-like layer formation particularly bound to the regions with the highest Al content were revealed. The functional and structural information obtained at molecular and subcellular level contributes to a better understanding of the macroscopic inflammatory processes observed in the tissue level. The established label-free correlative microscopy approach can efficiently be adopted to study any other clinical cases related to ALTR.
Collapse
|
9
|
Early changes of ECM-related gene expression in fibroblasts cultured on TiO2, ZrO2 and PEEK: The beneficial effects of UVC photofunctionalization. JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY 2021. [DOI: 10.1016/j.jpap.2021.100023] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023] Open
|
10
|
Custom-Made Zirconium Dioxide Implants for Craniofacial Bone Reconstruction. MATERIALS 2021; 14:ma14040840. [PMID: 33578685 PMCID: PMC7916391 DOI: 10.3390/ma14040840] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/28/2020] [Revised: 02/05/2021] [Accepted: 02/07/2021] [Indexed: 11/18/2022]
Abstract
Reconstruction of the facial skeleton is challenging for surgeons because of difficulties in proper shape restoration and maintenance of the proper long-term effect. ZrO2 implant application can be a solution with many advantages (e.g., osseointegration, stability, and radio-opaqueness) and lacks the disadvantages of other biomaterials (e.g., metalosis, radiotransparency, and no osseointegration) or autologous bone (e.g., morbidity, resorption, and low accuracy). We aimed to evaluate the possibility of using ZrO2 implants as a new application of this material for craniofacial bone defect reconstruction. First, osteoblast (skeleton-related cell) cytotoxicity and genotoxicity were determined in vitro by comparing ZrO2 implants and alumina particle air-abraded ZrO2 implants to the following: 1. a titanium alloy (standard material); 2. ultrahigh-molecular-weight polyethylene (a modern material used in orbital surgery); 3. a negative control (minimally cytotoxic or genotoxic agent action); 4. a positive control (maximally cytotoxic or genotoxic agent action). Next, 14 custom in vivo clinical ZrO2 implants were manufactured for post-traumatologic periorbital region reconstruction. The soft tissue position improvement in photogrammetry was recorded, and clinical follow-up was conducted at least 6 years postoperatively. All the investigated materials revealed no cytotoxicity. Alumina particle air-abraded ZrO2 implants showed genotoxicity compared to those without subjection to air abrasion ZrO2, which were not genotoxic. The 6-month and 6- to 8-year clinical results were aesthetic and stable. Skeleton reconstructions using osseointegrated, radio-opaque, personalized implants comprising ZrO2 material are the next option for craniofacial surgery.
Collapse
|
11
|
Basha SA, Agrawal AK, Sarkar D. Tailor-made design, fabrication and validation of SrO doped nanostructured ZTA ceramic Femoral head - Acetabular socket liner assembly. J Mech Behav Biomed Mater 2020; 114:104178. [PMID: 33139239 DOI: 10.1016/j.jmbbm.2020.104178] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2020] [Revised: 10/21/2020] [Accepted: 10/23/2020] [Indexed: 01/01/2023]
Abstract
An established commercial grade SrO doped ZTA composition has been considered to design, fabrication through uniaxial pressing followed by sintering and polishing, validation of dimension, 3D surface profile, 3D microstructure, and compressive load bearing capacity of femoral head - acetabular socket liner prototypes for the hip prosthesis. While design and dimensions are concerned, both the steel (HRC60) molds were designed and machined to achieve precious dimensions of femoral head (FH; OD - 30 ± 0.01 mm) and acetabular socket liner (ASL; ID - 30.15 ± 0.01 mm). A close variation in the range of ±0.01 mm was confirmed the precision geometry of polished FH and ASL with consideration of 22 points coordinate measuring method (CMM). 3D surface profile ensures the surface characteristics of Ra = 0.2 ± 0.01 μm and Rq = 0.5 ± 0.01 μm for outer surface of FH and an inner surface of ASL, respectively. Structure integrity and fabrication defects including cracks and pores free bulk structures were confirmed by Micro CT. The compressive load resistance known as burst strength for independent FH and FH-ASL assembly were measured 16.2 KN and 17.6 KN, respectively. The developed ceramic prototypes have an economic advantage and can be adopted as artificial hip prosthesis after extensive in-vitro and in-vivo analysis.
Collapse
Affiliation(s)
- Shaik Akbar Basha
- Department of Ceramic Engineering, National Institute of Technology, Rourkela, Odisha, India
| | - Ashish Kumar Agrawal
- Technical Physics Division, Bhabha Atomic Research Centre, Mumbai, 400085, India
| | - Debasish Sarkar
- Department of Ceramic Engineering, National Institute of Technology, Rourkela, Odisha, India; Center for Nanomaterials, National Institute of Technology, Rourkela, Odisha, India.
| |
Collapse
|
12
|
He X, Reichl FX, Milz S, Michalke B, Wu X, Sprecher CM, Yang Y, Gahlert M, Röhling S, Kniha H, Hickel R, Högg C. Titanium and zirconium release from titanium- and zirconia implants in mini pig maxillae and their toxicity in vitro. Dent Mater 2020; 36:402-412. [DOI: 10.1016/j.dental.2020.01.013] [Citation(s) in RCA: 31] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2019] [Revised: 12/02/2019] [Accepted: 01/14/2020] [Indexed: 11/17/2022]
|
13
|
Has zirconia made a material difference in implant prosthodontics? A review. Dent Mater 2020; 36:1-8. [DOI: 10.1016/j.dental.2019.08.100] [Citation(s) in RCA: 28] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2019] [Accepted: 08/19/2019] [Indexed: 12/17/2022]
|
14
|
Björnmalm M, Wong LM, Wojciechowski JP, Penders J, Horgan CC, Booth MA, Martin NG, Sattler S, Stevens MM. In vivo biocompatibility and immunogenicity of metal-phenolic gelation. Chem Sci 2019; 10:10179-10194. [PMID: 31700596 PMCID: PMC6837883 DOI: 10.1039/c9sc03325d] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2019] [Accepted: 09/13/2019] [Indexed: 12/19/2022] Open
Abstract
In vivo forming hydrogels are of interest for diverse biomedical applications due to their ease-of-use and minimal invasiveness and therefore high translational potential. Supramolecular hydrogels that can be assembled using metal-phenolic coordination of naturally occurring polyphenols and group IV metal ions (e.g. TiIV or ZrIV) provide a versatile and robust platform for engineering such materials. However, the in situ formation and in vivo response to this new class of materials has not yet been reported. Here, we demonstrate that metal-phenolic supramolecular gelation occurs successfully in vivo and we investigate the host response to the material over 14 weeks. The TiIV-tannic acid materials form stable gels that are well-tolerated following subcutaneous injection. Histology reveals a mild foreign body reaction, and titanium biodistribution studies show low accumulation in distal tissues. Compared to poloxamer-based hydrogels (commonly used for in vivo gelation), TiIV-tannic acid materials show a substantially improved in vitro drug release profile for the corticosteroid dexamethasone (from <1 day to >10 days). These results provide essential in vivo characterization for this new class of metal-phenolic hydrogels, and highlight their potential suitability for biomedical applications in areas such as drug delivery and regenerative medicine.
Collapse
Affiliation(s)
- Mattias Björnmalm
- Department of Materials
, Department of Bioengineering
, Institute of Biomedical Engineering
, Imperial College London
,
London SW7 2AZ
, UK
.
| | - Lok Man Wong
- National Heart and Lung Institute
, Imperial College London
,
London W12 0NN
, UK
.
| | - Jonathan P. Wojciechowski
- Department of Materials
, Department of Bioengineering
, Institute of Biomedical Engineering
, Imperial College London
,
London SW7 2AZ
, UK
.
| | - Jelle Penders
- Department of Materials
, Department of Bioengineering
, Institute of Biomedical Engineering
, Imperial College London
,
London SW7 2AZ
, UK
.
| | - Conor C. Horgan
- Department of Materials
, Department of Bioengineering
, Institute of Biomedical Engineering
, Imperial College London
,
London SW7 2AZ
, UK
.
| | - Marsilea A. Booth
- Department of Materials
, Department of Bioengineering
, Institute of Biomedical Engineering
, Imperial College London
,
London SW7 2AZ
, UK
.
| | - Nicholas G. Martin
- Trace Element Laboratory
, North West London Pathology
,
Charing Cross Hospital
, London W6 8RF
, UK
| | - Susanne Sattler
- National Heart and Lung Institute
, Imperial College London
,
London W12 0NN
, UK
.
| | - Molly M. Stevens
- Department of Materials
, Department of Bioengineering
, Institute of Biomedical Engineering
, Imperial College London
,
London SW7 2AZ
, UK
.
| |
Collapse
|
15
|
Chatterjee S, Kobylinski S, Basu B. Finite Element Analysis to Probe the Influence of Acetabular Shell Design, Liner Material, and Subject Parameters on Biomechanical Response in Periprosthetic Bone. J Biomech Eng 2019; 140:2681672. [PMID: 30029239 DOI: 10.1115/1.4040249] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2018] [Indexed: 11/08/2022]
Abstract
The implant stability and biomechanical response of periprosthetic bone in acetabulum around total hip joint replacement (THR) devices depend on a host of parameters, including design of articulating materials, gait cycle and subject parameters. In this study, the impact of shell design (conventional, finned, spiked, and combined design) and liner material on the biomechanical response of periprosthetic bone has been analyzed using finite element (FE) method. Two different liner materials: high density polyethylene-20% hydroxyapatite-20% alumina (HDPE-20%HA-20%Al2O3) and highly cross-linked ultrahigh molecular weight polyethylene (HC-UHMWPE) were used. The subject parameters included bone condition and bodyweight. Physiologically relevant load cases of a gait cycle were considered. The deviation of mechanical condition of the periprosthetic bone due to implantation was least for the finned shell design. No significant deviation was observed at the bone region adjacent to the spikes and the fins. This study recommends the use of the finned design, particularly for weaker bone conditions. For stronger bones, the combined design may also be recommended for higher stability. The use of HC-UHMWPE liner was found to be better for convensional shell design. However, similar biomechanical response was captured in our FE analysis for both the liner materials in case of other shell designs. Overall, the study establishes the biomechanical response of periprosthetic bone in the acetabular with preclinically tested liner materials together with new shell design for different subject conditions.
Collapse
Affiliation(s)
- Subhomoy Chatterjee
- Materials Research Centre, Indian Institute of Science, Bengaluru 560012, Karnataka, India; Translational Center on Biomaterials for Orthopaedic and Dental Applications, Indian Institute of Science, Bengaluru 560012, Karnataka, India
| | - Sabine Kobylinski
- Materials Research Centre, Indian Institute of Science, Bengaluru 560012, Karnataka, India; Centre for BioSystems and Engineering, Indian Institute of Science, Bengaluru 560012, Karnataka, India; Technical University of Applied Sciences Regensburg (OTH Regensburg), Regensburg 93047, Germany
| | - Bikramjit Basu
- Materials Research Centre, Indian Institute of Science, Bengaluru 560012, Karnataka, India; Translational Center on Biomaterials for Orthopaedic and Dental Applications, Indian Institute of Science, Bengaluru 560012, Karnataka, India; Centre for BioSystems and Engineering, Indian Institute of Science, Bengaluru 560012, Karnataka, India e-mails:
| |
Collapse
|
16
|
Swiatkowska I, Martin N, Hart AJ. Blood titanium level as a biomarker of orthopaedic implant wear. J Trace Elem Med Biol 2019; 53:120-128. [PMID: 30910194 DOI: 10.1016/j.jtemb.2019.02.013] [Citation(s) in RCA: 33] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/26/2018] [Revised: 02/18/2019] [Accepted: 02/27/2019] [Indexed: 12/12/2022]
Abstract
BACKGROUND Joint replacement implants are usually manufactured from cobalt-chromium or titanium alloys. After the device is implanted, wear and corrosion generate metal particles and ions, which are released into local tissue and blood. The metal debris can cause a range of adverse local and systemic effects in patients. RESEARCH PROBLEM In the case of cobalt and chromium, a blood level exceeding 7 μg L-1 indicates potential for local toxicity, and a failing implant. It has been repeatedly suggested in the literature that measurement of titanium could also be used to assess implant function. Despite an increasing interest in this biomarker, and growing use of titanium in orthopaedics, it is unclear what blood concentrations should raise concerns. This is partly due to the technical challenges involved in the measurement of titanium in biological samples. AIM This Review summarises blood/serum titanium levels associated with well-functioning and malfunctioning prostheses, so that the prospects of using titanium measurements to gain insights into implant performance can be evaluated. CONCLUSION Due to inter-laboratory analytical differences, reliable conclusions regarding "normal" and "abnormal" titanium levels in patients with orthopaedic implants are difficult to draw. Diagnosis of symptomatic patients should be based on radiographic evidence combined with blood/serum metal levels.
Collapse
Affiliation(s)
- Ilona Swiatkowska
- Institute of Orthopaedics and Musculoskeletal Science, University College London, HA7 4LP, Stanmore, UK.
| | - Nicholas Martin
- Trace Element Laboratory, Clinical Biochemistry, Charing Cross Hospital, W6 8RF, London, UK
| | - Alister J Hart
- Institute of Orthopaedics and Musculoskeletal Science, University College London, HA7 4LP, Stanmore, UK; Royal National Orthopaedic Hospital, Stanmore, HA7 4LP, UK
| |
Collapse
|
17
|
Bahraminasab M, Bozorg M, Ghaffari S, Kavakebian F. Corrosion of Al 2O 3-Ti composites under inflammatory condition in simulated physiological solution. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2019; 102:200-211. [PMID: 31146991 DOI: 10.1016/j.msec.2019.04.047] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/22/2018] [Revised: 03/12/2019] [Accepted: 04/14/2019] [Indexed: 12/21/2022]
Abstract
Alumina-titanium composites have shown good mechanical properties which makes them promising for orthopedic applications. The placement of an orthopedic implant involves an invasive procedure which stimulates a localized inflammatory response causing an acidic environment around the implant. This makes the study on corrosion more critical. Therefore, the aim of the present paper was to study the corrosion behavior of the composites with 75 vol% and 50 vol% Ti content (with alumina balance) fabricated by Spark Plasma Sintering under acidic condition representing inflammation and in two elapsed times (1 h and 1-day) using polarization and electrochemical impedance spectroscopy tests. For comparison, the experiments were also conducted in normal physiological solution after 1 h, and pure Ti (100vol%Ti) was fabricated by the same process and analyzed, similarly. Furthermore, behavior of the samples was studied after 48 days of immersion in the acidic and normal solutions using SEM, ATR-FTIR, AFM, and ICP-OES. The results of corrosion tests showed very good passivation behavior of 100vol%Ti and the composite containing 75vol.%Ti. The superiority of the 75vol.%Ti composite in corrosion characteristics in both solutions was also found. Its corrosion resistance was 20.3 MΩcm2 under the inflammatory condition after 1-day, which was 39% higher than that of 100vol.%Ti under the same condition. The results of SEM indicated both corroded and mineral deposition zones on all materials' surfaces and the ATR-FTIR results revealed additional adsorbed bands related to water adsorption, OH and carbonate groups after immersion. The AFM analysis showed rougher morphology, particularly for 75 vol% Ti where the Rq was increased about 50 nm, and the ICP-OES results indicated 65.87% and 61.94% deposition of solution calcium on 75vol.%Ti and 50vol.%Ti, respectively. The acidic/inflammatory condition influenced the corrosion processes of all materials. Lower pH caused the passivation to occur sooner and the corrosion resistance to be higher.
Collapse
Affiliation(s)
- Marjan Bahraminasab
- Nervous System Stem Cells Research Center, Semnan University of Medical Sciences, Semnan, Iran; Department of Tissue Engineering and Applied Cell Sciences, School of Medicine, Semnan University of Medical Sciences, Semnan, Iran.
| | - Mansoor Bozorg
- Department of Chemical & Materials Engineering, Shahrood University of Technology, Shahrood 3619995161, Iran
| | - Somaye Ghaffari
- Department of Ceramics, Materials and Energy Research Center, P.O. Box 31787316, Karaj, Alborz, Iran
| | - Fatemeh Kavakebian
- Nervous System Stem Cells Research Center, Semnan University of Medical Sciences, Semnan, Iran
| |
Collapse
|
18
|
Abstract
Implant surface micro and macro topography plays a key role in early osseointegration. The physicochemical features of the implant surface (ie, chemical composition, hydrophobicity/hydrophilicity and roughness) influence the deposition of extracellular matrix proteins, the precipitation of bone mineral, and the stimulation of cells. Modification of the implant topography provides better primary stability and faster osseointegration, allowing for immediate placement or immediate loading. Randomized clinical trials are warranted to compare the response of osseointegration with various implant micro and macro surface topographies in people with various local or systemic risk factors.
Collapse
Affiliation(s)
- Khalid Almas
- Division of Periodontology, Department of Preventive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, P O Box. 1982, Dammam 31441, Saudi Arabia.
| | - Steph Smith
- Division of Periodontology, Department of Preventive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, P O Box. 1982, Dammam 31441, Saudi Arabia
| | - Ahmad Kutkut
- Division of Prosthodontics, University of Kentucky, College of Dentistry, D646, 800 Rose Street, Lexington, KY 40536, USA
| |
Collapse
|
19
|
Condi Mainardi J, Rezwan K, Maas M. Embedding live bacteria in porous hydrogel/ceramic nanocomposites for bioprocessing applications. Bioprocess Biosyst Eng 2019; 42:1215-1224. [PMID: 30953175 DOI: 10.1007/s00449-019-02119-4] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2018] [Accepted: 03/29/2019] [Indexed: 11/24/2022]
Abstract
In this work, we present a biocompatible one-pot processing route for ceramic/hydrogel nanocomposites in which we embed live bacteria. In our approach, we fabricate a highly stable alginate hydrogel with minimal shrinkage, highly increased structural and mechanical stability, as well as excellent biocompatibility. The hydrogel was produced by ionotropic gelation and reinforced with alumina nanoparticles to form a porous 3D network. In these composite gels, the bacteria Escherichia coli and Bacillus subtilis were embedded. The immobilized bacteria showed high viability and similar metabolic activity as non-embedded cells. Even after repeated glucose consumption cycles, the material maintained high structural stability with stable metabolic activity of the immobilized bacteria. Storing the bionanocomposite for up to 60 days resulted in only minor loss of activity. Accordingly, this approach shows great potential for producing macroscopic bioactive materials for biotechnological processes.
Collapse
Affiliation(s)
- Jessica Condi Mainardi
- Keramische Werkstoffe und Bauteile, Advanced Ceramics, Universität Bremen, Am Biologischen Garten 2-IW 3, Raum 2140, 28359, Bremen, Germany
| | - Kurosch Rezwan
- Keramische Werkstoffe und Bauteile, Advanced Ceramics, Universität Bremen, Am Biologischen Garten 2-IW 3, Raum 2140, 28359, Bremen, Germany.,MAPEX Center for Materials and Processes, University of Bremen, Am Fallturm 1, 28359, Bremen, Germany
| | - Michael Maas
- Keramische Werkstoffe und Bauteile, Advanced Ceramics, Universität Bremen, Am Biologischen Garten 2-IW 3, Raum 2140, 28359, Bremen, Germany. .,MAPEX Center for Materials and Processes, University of Bremen, Am Fallturm 1, 28359, Bremen, Germany.
| |
Collapse
|
20
|
Marin E, Horiguchi S, Zanocco M, Boschetto F, Rondinella A, Zhu W, Bock RM, McEntire BJ, Adachi T, Bal BS, Pezzotti G. Bioglass functionalization of laser-patterned bioceramic surfaces and their enhanced bioactivity. Heliyon 2018; 4:e01016. [PMID: 30560211 PMCID: PMC6288463 DOI: 10.1016/j.heliyon.2018.e01016] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2018] [Revised: 11/05/2018] [Accepted: 12/04/2018] [Indexed: 11/29/2022] Open
Abstract
The surfaces of silicon nitride (β-Si3N4) and zirconia toughened alumina (ZTA) were patterned using a high-energy laser source, which operated at a wavelength of 1064 nm. The patterning procedure yielded a series regular, cylindrical cavities 500 and 300 μm in diameter and depth, respectively. These cavities were subsequently filled with bioglass mixed with different fractions of Si3N4 powder (0, 5, and 10 mol.%) to obtain bioactive functionalized bioceramic surfaces. The laser-patterned samples were first characterized using several spectroscopic techniques before and after functionalization, and then tested in vitro with respect to their osteoconductivity using a human osteosarcoma cell line (SaOS-2). After in vitro testing, fluorescence microscopy was used to address the biological response and to estimate osteopontin and osteocalcin protein contents and distributions. The presence of bioglass greatly enhanced the biological response of both ceramic surfaces, but mainly induced production of inorganic apatite. On the other hand, the addition of minor fraction of Si3N4 into the bioglass-filled holes greatly enhanced bio-mineralization and stimulated the SaOS-2 cells to produce higher amounts of bone extracellular matrix (collagen and proteins), thus enhancing the osteopontin to osteocalcin ratio. It was also observed that the presence of a fraction of Si3N4 in the powder mixture filling the holes bestowed more uniform cell colonization on the otherwise bioinert ZTA surface.
Collapse
Affiliation(s)
- Elia Marin
- Ceramic Physics Laboratory, Kyoto Institute of Technology, Sakyo-ku, Matsugasaki, 606-8585 Kyoto, Japan
- Department of Dental Medicine, Graduate School of Medical Science, Kyoto Prefectural University of Medicine, Kamigyo-ku, Kyoto 602-8566, Japan
| | - Satoshi Horiguchi
- Department of Dental Medicine, Graduate School of Medical Science, Kyoto Prefectural University of Medicine, Kamigyo-ku, Kyoto 602-8566, Japan
| | - Matteo Zanocco
- Ceramic Physics Laboratory, Kyoto Institute of Technology, Sakyo-ku, Matsugasaki, 606-8585 Kyoto, Japan
| | - Francesco Boschetto
- Ceramic Physics Laboratory, Kyoto Institute of Technology, Sakyo-ku, Matsugasaki, 606-8585 Kyoto, Japan
| | - Alfredo Rondinella
- Ceramic Physics Laboratory, Kyoto Institute of Technology, Sakyo-ku, Matsugasaki, 606-8585 Kyoto, Japan
| | - Wenliang Zhu
- Ceramic Physics Laboratory, Kyoto Institute of Technology, Sakyo-ku, Matsugasaki, 606-8585 Kyoto, Japan
| | - Ryan M. Bock
- Amedica Corporation, 1885 West 2100 South, Salt Lake City, UT, USA
| | | | - Tetsuya Adachi
- Department of Dental Medicine, Graduate School of Medical Science, Kyoto Prefectural University of Medicine, Kamigyo-ku, Kyoto 602-8566, Japan
| | - B. Sonny Bal
- Amedica Corporation, 1885 West 2100 South, Salt Lake City, UT, USA
- Department of Orthopaedic Surgery, University of Missouri, Columbia, MO, USA
| | - Giuseppe Pezzotti
- Ceramic Physics Laboratory, Kyoto Institute of Technology, Sakyo-ku, Matsugasaki, 606-8585 Kyoto, Japan
- Department of Immunology, Graduate School of Medical Science, Kyoto Prefectural University of Medicine, Kamigyo-ku, 465 Kajii-cho, Kawaramachi dori, 602-0841 Kyoto, Japan
- Department of Orthopedic Surgery, Tokyo Medical University, 6-7-1 Nishi-Shinjuku, Shinjuku-ku, 160-0023 Tokyo, Japan
- The Center for Advanced Medical Engineering and Informatics, Osaka University, Yamadaoka, Suita, 565-0871 Osaka, Japan
| |
Collapse
|
21
|
Bishal AK, Sukotjo C, Jokisaari JR, Klie RF, Takoudis CG. Enhanced Bioactivity of Collagen Fiber Functionalized with Room Temperature Atomic Layer Deposited Titania. ACS APPLIED MATERIALS & INTERFACES 2018; 10:34443-34454. [PMID: 30212175 DOI: 10.1021/acsami.8b05857] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/11/2023]
Abstract
Surface modifications of a biomaterial like collagen are crucial in improving the surface properties and thus enhancing the functionality and performance of such a material for a variety of biomedical applications. In this study, a commercially available collagen membrane's surface was functionalized by depositing an ultrathin film of titania or titanium dioxide (TiO2) using a room temperature atomic layer deposition (ALD) process. A novel titanium precursor-oxidizer combination was used for this process in a custom-made ALD reactor. Surface characterizations revealed successful deposition of uniform, conformal TiO2 thin film on the collagen fibrillar surface, and consequently, the fibers became thicker making the membrane pores smaller. The in vitro bioactivity of the ALD-TiO2 thin film coated collagen was investigated for the first time using cell proliferation and a calcium phosphate mineralization assay. The TiO2-coated collagen demonstrated improved biocompatibility promoting higher growth and proliferation of human osteoblastic and mesenchymal stem cells when compared to that of noncoated collagen. A higher level of calcium phosphate or apatite formation was observed on ALD modified collagen surface as compared to that on noncoated collagen. Therefore, this novel material can be promising in bone tissue engineering applications.
Collapse
Affiliation(s)
- Arghya K Bishal
- Department of Bioengineering , University of Illinois at Chicago , Chicago , Illinois 60607 , United States
| | - Cortino Sukotjo
- Department of Bioengineering , University of Illinois at Chicago , Chicago , Illinois 60607 , United States
- Restorative Dentistry, College of Dentistry , University of Illinois at Chicago , Chicago , Illinois 60612 , United States
| | - Jacob R Jokisaari
- Department of Physics , University of Illinois at Chicago , Chicago , Illinois 60607 , United States
| | - Robert F Klie
- Department of Physics , University of Illinois at Chicago , Chicago , Illinois 60607 , United States
| | - Christos G Takoudis
- Department of Bioengineering , University of Illinois at Chicago , Chicago , Illinois 60607 , United States
- Department of Chemical Engineering , University of Illinois at Chicago , Chicago , Illinois 60607 , United States
| |
Collapse
|
22
|
Bhaskar N, Sarkar D, Basu B. Probing Cytocompatibility, Hemocompatibility, and Quantitative Inflammatory Response in Mus musculus toward Oxide Bioceramic Wear Particulates and a Comparison with CoCr. ACS Biomater Sci Eng 2018; 4:3194-3210. [DOI: 10.1021/acsbiomaterials.8b00583] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Affiliation(s)
- Nitu Bhaskar
- Laboratory for Biomaterials, Materials Research Centre, Indian Institute of Science, Bangalore-560012, India
| | - Debasish Sarkar
- Department of Ceramic Engineering, National Institute of Technology, Rourkela, Odisha 769004, India
| | - Bikramjit Basu
- Laboratory for Biomaterials, Materials Research Centre, Indian Institute of Science, Bangalore-560012, India
- Center for Biosystems Science and Engineering, Indian Institute of Science, Bangalore-560012, India
| |
Collapse
|
23
|
Bertrand J, Delfosse D, Mai V, Awiszus F, Harnisch K, Lohmann CH. Ceramic prosthesis surfaces induce an inflammatory cell response and fibrotic tissue changes. Bone Joint J 2018; 100-B:882-890. [DOI: 10.1302/0301-620x.100b7.bjj-2017-1590.r2] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Aims Early evidence has emerged suggesting that ceramic-on-ceramic articulations induce a different tissue reaction to ceramic-on-polyethylene and metal-on-metal bearings. Therefore, the aim of this study was to investigate the tissue reaction and cellular response to ceramic total hip arthroplasty (THA) materials in vitro, as well as the tissue reaction in capsular tissue after revision surgery of ceramic-on-ceramic THAs. Patients and Methods We investigated tissue collected at revision surgery from nine ceramic-on-ceramic articulations. we compared our findings with tissue obtained from five metal-on-metal THA revisions, four ceramic-on-polyethylene THAs, and four primary osteoarthritis synovial membranes. The latter were analyzed to assess the amount of tissue fibrosis that might have been present at the time of implantation to enable evaluation, in relation to implantation time, of any subsequent response in the tissues. Results There was a significant increase in tissue fibrosis with implantation time for all implant types tested. Interestingly, the tissue fibrosis in ceramic-on-ceramic THAs was significantly increased compared with metal-on-metal and ceramic-on-polyethylene. Additionally, we found ceramic wear particles in the periprosthetic tissue of ceramic implants. Fibroblasts responded with expression of cytokines when cultured on alumina-toughened zirconia (ATZ) and zirconia-toughened alumina (ZTA) ceramic surfaces. This response was more pronounced on ATZ ceramics compared with ZTA ceramics. The same inflammatory response was observed with peripheral blood mononuclear cells (PBMCs) cultured on ZTA and ATZ. Conclusion Our findings therefore, corroborate the previous findings that ceramic-on-ceramic periprosthetic revision tissue is fibrous and offer an explanation for this observation. We detected a long-term inflammatory response of PBMCs and an inflammatory response of fibroblasts to ATZ and ZTA ceramic. These findings partially explain the fibrotic tissue change in periprosthetic tissue of ceramic-on-ceramic bearings. Cite this article: Bone Joint J 2018;100-B:882–90.
Collapse
Affiliation(s)
- J. Bertrand
- Department of Orthopaedic Surgery, Otto-von-Guericke
University, Magdeburg, Germany
| | | | - V. Mai
- Mathys AG Bettlach, Bettlach, Switzerland
| | - F. Awiszus
- Department of Orthopaedic Surgery, Otto-von-Guericke
University, Magdeburg, Germany
| | - K. Harnisch
- Institute for Materials and Joining Technology,
Otto-von-Guericke University, Magdeburg, Germany
| | - C. H. Lohmann
- Department of Orthopaedic Surgery, Otto-von-Guericke
University, Magdeburg, Germany
| |
Collapse
|
24
|
Mostafa D, Aboushelib M. Bioactive-hybrid-zirconia implant surface for enhancing osseointegration: an in vivo study. Int J Implant Dent 2018; 4:20. [PMID: 29900480 PMCID: PMC5999599 DOI: 10.1186/s40729-018-0129-3] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2018] [Accepted: 04/23/2018] [Indexed: 11/12/2022] Open
Abstract
Background Zirconia is characterized by a hard, dense, and chemically inert surface which requires additional surface treatments in order to enhance osseointegration. The proposed hypothesis of the study was that combination of a nano-porous surface infiltrated with a bioactive material may enhance osseointegration of zirconia implants. Methods Custom-made zirconia implants (3.7 mm × 8 mm) were designed, milled, and sintered according to manufacturer recommendations. All implants received selective infiltration etching (SIE) technique to produce a nano-porous surface. Surface porosities were either filled with nano-hydroxy apatite particle- or platelet-rich plasma while uncoated surface served as a control (n = 12, α = 0.05). New surface properties were characterized with mercury porosimetry, XRD analysis, SEM, and EDX analysis. Implants were inserted in femur head of rabbits, and histomorphometric analysis was conducted after healing time to evaluate bone–implant contact percentage (BIC%). Results Selective infiltration etching produced a nano-porous surface with interconnected surface porosities. Mercury porosimetry revealed a significant reduction in total porosity percent after application of the two coating materials. XRD patterns detected hexagonal crystal structure of HA superimposed on the tetragonal crystal phase of zirconia. Histomorphometric analysis indicated a significantly higher (F = 14.6, P < 0.001) BIC% around HA–bioactive–hybrid surface (79.8 ± 3%) and PRP-coated surface (71 ± 6 %) compared to the control (49 ± 8%). Conclusions Bioactive–hybrid–zirconia implant surface enhanced osseointegration of zirconia implants.
Collapse
Affiliation(s)
- Dawlat Mostafa
- Dental Biomaterials, Faculty of Dentistry, Alexandria University, Champolion St., Azarita, Alexandria, Egypt
| | - Moustafa Aboushelib
- Dental Biomaterials, Faculty of Dentistry, Alexandria University, Champolion St., Azarita, Alexandria, Egypt.
| |
Collapse
|
25
|
Tosiriwatanapong T, Singhatanadgit W. Zirconia-Based Biomaterials for Hard Tissue Reconstruction. ACTA ACUST UNITED AC 2018. [DOI: 10.1177/1179061x18767886] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Implantable biomaterials are increasingly important in the practice of modern medicine, including fixative, replacement, and regeneration therapies, for reconstruction of hard tissues in patients with pathologic osseous and dental conditions. A number of newly developed advanced biomaterials have been introduced as promising candidates for tissue reconstruction. Among these, zirconia-based biomaterials have gained attention as a biomaterial for hard tissue reconstruction due to superior mechanical properties and good chemical and biological compatibilities. This review summarizes the types of zirconia, advantages of zirconia-based biomaterials for hard tissue reconstruction including bone and dental tissues, responses of tissue and cells to zirconia, and surface modifications for enhanced bioactivity of zirconia. Current and future applications of zirconia-based biomaterials for bone and dental reconstruction, ie, medical implanted devices, dental prostheses, and biocompatible osteogenic scaffolds, are also discussed.
Collapse
|
26
|
Li Z, Ma S, Zhang G, Wang D, Zhou F. Soft/Hard-Coupled Amphiphilic Polymer Nanospheres for Water Lubrication. ACS APPLIED MATERIALS & INTERFACES 2018; 10:9178-9187. [PMID: 29468880 DOI: 10.1021/acsami.8b00405] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/18/2023]
Abstract
Amphiphilic polymer nanospheres of poly(3-sulfopropyl methacrylate potassium salt- co-styrene) [P(SPMA- co-St)] were prepared by a simple soap-free emulsion polymerization method and used as efficient water lubrication additives to enhance the antiwear behaviors of the Ti6Al4V alloy. The monodisperse and flexible P(SPMA- co-St) bicomponent copolymer nanospheres were synthesized with a controllable manner by adjusting the mass fraction ratio of the monomers, with the hydrophobic polystyrene (PSt) as the hard skeletal carrier component and the hydrophilic PSPMA with a hydration layer structure as the soft lubrication layer in the course of friction. The influences of the monomer concentration, the copolymer nanosphere additive content, the load, and the frequency of the friction conditions on their tribological properties were studied in detail, and a probable antiwear mechanism of the soft/hard-coupled copolymer nanospheres under water lubrication was also proposed. The results show that compared with pure PSt, the P(SPMA- co-St) polymer nanospheres exhibited better antiwear property as an additive for water lubrication, and the friction coefficient and the wear volume first decreased and then increased with the increase of the SPMA content, indicating that the hydrophilic SPMA has a significant effect on lubrication properties owing to its hydration performance. Furthermore, with the increase of polymer nanosphere concentration, the friction coefficient and wear amount also decreased to a stable and low value at a saturation concentration of 1 wt %. The flexible polymer nanospheres with a hydrophilic soft SPMA shell and a rigid PSt core exhibited good friction-reduction and antiwear performance as lubrication additives, indicating their promising and potential applications in water lubrication and biological lubrication.
Collapse
Affiliation(s)
- Zhaoxia Li
- State Key Laboratory of Solid Lubrication, Lanzhou Institute of Chemical Physics , Chinese Academy of Sciences , Lanzhou 730000 , China
- University of Chinese Academy of Sciences , Beijing 100049 , China
| | - Shuanhong Ma
- State Key Laboratory of Solid Lubrication, Lanzhou Institute of Chemical Physics , Chinese Academy of Sciences , Lanzhou 730000 , China
| | - Ga Zhang
- State Key Laboratory of Solid Lubrication, Lanzhou Institute of Chemical Physics , Chinese Academy of Sciences , Lanzhou 730000 , China
| | - Daoai Wang
- State Key Laboratory of Solid Lubrication, Lanzhou Institute of Chemical Physics , Chinese Academy of Sciences , Lanzhou 730000 , China
- Qingdao Center of Resource Chemistry and New Materials , Qingdao 266100 , China
| | - Feng Zhou
- State Key Laboratory of Solid Lubrication, Lanzhou Institute of Chemical Physics , Chinese Academy of Sciences , Lanzhou 730000 , China
| |
Collapse
|
27
|
Martins R, Cestari TM, Arantes RVN, Santos PS, Taga R, Carbonari MJ, Oliveira RC. Osseointegration of zirconia and titanium implants in a rabbit tibiae model evaluated by microtomography, histomorphometry and fluorochrome labeling analyses. J Periodontal Res 2017; 53:210-221. [PMID: 29044523 DOI: 10.1111/jre.12508] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/01/2017] [Indexed: 02/02/2023]
Abstract
OBJECTIVES This study compares the osseointegration of machined-zirconia implants containing yttria (M-Y-TZP) with machined (M-Ti) and resorbable blast media (RBM-Ti) titanium implants. MATERIAL AND METHODS M-Y-TZP, M-Ti and RBM-Ti implants were randomly placed in rabbit tibiae. Fluorochrome bone labels (tetracycline, alizarin and calcein) were administered at different time periods. After 8 weeks, osseointegration was evaluated in terms of bone-to-implant contact (BIC), new bone area (nBA), remaining cortical bone area (rBA) and temporal quantification of fluorochromes, using micro-CT and histomorphometric analyses. RESULTS RBM-Ti implants showed higher resorption of the remaining cortical bone and bone formation (rBA = 36.9% and nBA = 38.8%) than M-Y-TZP implants (rBA = 48% and nBA = 26.5%). The BIC values showed no differences among the groups in the cortical region (mean = 52.2%) but in the medullary region, they were 0.45-fold higher in the RBM-Ti group (51.2%) than in the M-Y-TZP group (35.2%). In all groups, high incorporation of tetracycline was observed (2nd to 4th weeks), followed by alizarin (4th to 6th weeks) and calcein (6th to 8th weeks). In the cortical region, incorporation of tetracycline was similar between RBM-Ti (49.8%) and M-Y-TZP (35.9%) implants, but higher than M-Ti (28.2%) implants. Subsequently, alizarin and calcein were 1.1-fold higher in RBM-Ti implants than in the other implants. In the medullary region, no significant differences were observed for all fluorochromes. CONCLUSION All implants favored bone formation and consequently promoted primary stability. Bone formation around the threads was faster in RBM-Ti and M-Y-TZP implants than in M-Ti implants, but limited bone remodeling with M-Y-TZP implants over time can have significant effects on secondary stability, suggesting caution for its use as an alternative substitute for titanium implants.
Collapse
Affiliation(s)
- R Martins
- Department of Biological Sciences, Bauru School of Dentistry, University of São Paulo, Bauru, SP, Brazil
| | - T M Cestari
- Department of Biological Sciences, Bauru School of Dentistry, University of São Paulo, Bauru, SP, Brazil
| | - R V N Arantes
- Department of Biological Sciences, Bauru School of Dentistry, University of São Paulo, Bauru, SP, Brazil
| | - P S Santos
- Department of Biological Sciences, Bauru School of Dentistry, University of São Paulo, Bauru, SP, Brazil
| | - R Taga
- Department of Biological Sciences, Bauru School of Dentistry, University of São Paulo, Bauru, SP, Brazil
| | - M J Carbonari
- Insper - Instituto de Ensino e Pesquisa, São Paulo, SP, Brazil
| | - R C Oliveira
- Department of Biological Sciences, Bauru School of Dentistry, University of São Paulo, Bauru, SP, Brazil
| |
Collapse
|
28
|
Curcumin Attenuation of Wear Particle-Induced Osteolysis via RANKL Signaling Pathway Suppression in Mouse Calvarial Model. Mediators Inflamm 2017; 2017:5784374. [PMID: 29085185 PMCID: PMC5632469 DOI: 10.1155/2017/5784374] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2017] [Accepted: 08/08/2017] [Indexed: 11/17/2022] Open
Abstract
Wear particle-induced chronic inflammation and osteoclastogenesis are two critical factors in the osteolytic process. Curcumin (CUR) is an active compound of the medicinal herb Curcuma longa and has anti-inflammatory and antiosteoclastogenic properties. Our study tested the hypothesis that CUR might attenuate polymethylmethacrylate- (PMMA-) induced inflammatory osteolysis using mouse calvaria osteolysis model in vivo and in vitro. The mice were divided into four groups: phosphate-buffered saline group, CUR, PMMA, and PMMA + CUR groups. Three days before PMMA particle implantation, the mice were intraperitoneally injected with CUR (25 mg/kg/day). Ten days after the operation, the mouse calvaria was harvested for microcomputed tomography, histomorphometry, and molecular biology analysis. As expected, CUR markedly reduced the secretion of tumor necrosis factor-α, interleukin- (IL-) 1β, and IL-6 in the calvarial organ culture. Moreover, CUR suppressed osteoclastogenesis and decreased bone resorption in vivo compared with PMMA-stimulated calvaria. Furthermore, CUR downregulated the osteoclast-specific gene expression and reversed the receptor activator of nuclear factor kappa-B ligand (RANKL)/osteoprotegerin messenger RNA and protein ratio in PMMA particle-stimulated mice. These results suggest that CUR attenuated PMMA particle-induced inflammatory osteolysis by suppressing the RANKL signaling pathway in the murine calvarium, which could be a candidate compound to prevent and treat AL.
Collapse
|
29
|
Chen K, Liu J, Yang X, Zhang D. Preparation, optimization and property of PVA-HA/PAA composite hydrogel. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2017; 78:520-529. [DOI: 10.1016/j.msec.2017.04.117] [Citation(s) in RCA: 44] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/03/2017] [Revised: 04/19/2017] [Accepted: 04/19/2017] [Indexed: 11/29/2022]
|
30
|
Zhang D, Quayle MJ, Petersson G, van Ommen JR, Folestad S. Atomic scale surface engineering of micro- to nano-sized pharmaceutical particles for drug delivery applications. NANOSCALE 2017; 9:11410-11417. [PMID: 28678265 DOI: 10.1039/c7nr03261g] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
Atomic layer deposition on pharmaceutical particles for drug delivery applications is demonstrated using assisted fluidized bed dry powder processing. Complete and conformal layering is achieved on particle sizes from the lower micron to upper nanometer range under near ambient conditions. As few as 2-14 atomic alumina layers alter particle properties: dissolution, dispersibility and heat transfer.
Collapse
Affiliation(s)
- D Zhang
- AstraZeneca R&D Gothenburg, Pepparedsleden 1, Mölndal, SE-431 83, Sweden.
| | | | | | | | | |
Collapse
|
31
|
Immunological Responses to Total Hip Arthroplasty. J Funct Biomater 2017; 8:jfb8030033. [PMID: 28762999 PMCID: PMC5618284 DOI: 10.3390/jfb8030033] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2017] [Revised: 07/19/2017] [Accepted: 07/25/2017] [Indexed: 12/12/2022] Open
Abstract
The use of total hip arthroplasties (THA) has been continuously rising to meet the demands of the increasingly ageing population. To date, this procedure has been highly successful in relieving pain and restoring the functionality of patients’ joints, and has significantly improved their quality of life. However, these implants are expected to eventually fail after 15–25 years in situ due to slow progressive inflammatory responses at the bone-implant interface. Such inflammatory responses are primarily mediated by immune cells such as macrophages, triggered by implant wear particles. As a result, aseptic loosening is the main cause for revision surgery over the mid and long-term and is responsible for more than 70% of hip revisions. In some patients with a metal-on-metal (MoM) implant, metallic implant wear particles can give rise to metal sensitivity. Therefore, engineering biomaterials, which are immunologically inert or support the healing process, require an in-depth understanding of the host inflammatory and wound-healing response to implanted materials. This review discusses the immunological response initiated by biomaterials extensively used in THA, ultra-high-molecular-weight polyethylene (UHMWPE), cobalt chromium (CoCr), and alumina ceramics. The biological responses of these biomaterials in bulk and particulate forms are also discussed. In conclusion, the immunological responses to bulk and particulate biomaterials vary greatly depending on the implant material types, the size of particulate and its volume, and where the response to bulk forms of differing biomaterials are relatively acute and similar, while wear particles can initiate a variety of responses such as osteolysis, metal sensitivity, and so on.
Collapse
|
32
|
Yang G, Chen X, Yan Z, Zhu Q, Yang C. CD11b promotes the differentiation of osteoclasts induced by RANKL through the spleen tyrosine kinase signalling pathway. J Cell Mol Med 2017; 21:3445-3452. [PMID: 28661042 PMCID: PMC5706498 DOI: 10.1111/jcmm.13254] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2016] [Accepted: 04/24/2017] [Indexed: 12/28/2022] Open
Abstract
Macrophage surface antigen‐1 (Mac‐1, CD11b/CD18) has been implicated in the regulation of osteoclastogenesis. In the synovial tissues of patients with aseptic loosening after total hip replacement, CD11b was up‐regulated, which indicated that CD11b is closely involved in osteolysis around the prosthesis. We found that CD11b, but not CD18, promoted osteoclast (OC) maturation. Here, we show CD11b up‐regulated the levels of spleen tyrosine kinase (Syk), c‐Fos and nuclear factor of activated T cells, cytoplasmic‐1 (NFATc1), as well as the activity of extracellular‐regulated kinase (Erk), and as a result, osteoclast precursors (OCPs) differentiated and became tartrate‐resistant acid phosphatase (TRAP)‐positive. In addition, increased tumour necrosis factor‐α (TNF‐α) induced by ultra‐high molecular weight polyethylene (UHMWPE) particles up‐regulated the level of CD11b. Taken together, these findings suggest that CD11b is a positive regulator of osteoclastogenesis and that it functions by activating the Syk signalling pathway, while CD18 does not have the same effect.
Collapse
Affiliation(s)
- Guoxi Yang
- Institute of Orthopaedic Surgery, Xijing Hospital, The Fourth Military Medical University, Xi'an, China
| | - Xiaoyong Chen
- Institute of Orthopaedic Surgery, Xijing Hospital, The Fourth Military Medical University, Xi'an, China
| | - Zhao Yan
- Institute of Orthopaedic Surgery, Xijing Hospital, The Fourth Military Medical University, Xi'an, China
| | - Qingsheng Zhu
- Institute of Orthopaedic Surgery, Xijing Hospital, The Fourth Military Medical University, Xi'an, China
| | - Chongfei Yang
- Institute of Orthopaedic Surgery, Xijing Hospital, The Fourth Military Medical University, Xi'an, China
| |
Collapse
|
33
|
Badran Z, Struillou X, Hughes FJ, Soueidan A, Hoornaert A, Ide M. Silicon Nitride (Si3N4) Implants: The Future of Dental Implantology? J ORAL IMPLANTOL 2017; 43:240-244. [DOI: 10.1563/aaid-joi-d-16-00146] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
For decades titanium has been the preferred material for dental implant fabrication, with mechanical and biological performance resulting in high clinical success rates. These have been further enhanced by incremental development of surface modifications aimed at improving speed and degree of osseointegration and resulting in enhanced clinical treatment options and outcomes. However, increasing demand for metal-free dental restorations has also led to the development of ceramic-based dental implants, such as zirconia. In orthopedics, alternative biomaterials, such as polyetheretherketone or silicon nitride, have been used for implant applications. The latter is potentially of particular interest for oral use as it has been shown to have antibacterial properties. In this article we aim to shed light on this particular biomaterial as a future promising candidate for dental implantology applications, addressing basic specifications required for any dental implant material. In view of available preclinical data, silicon nitride seems to have the essential characteristics to be a candidate for dental implants material. This novel ceramic has a surface with potentially antimicrobial properties, and if this is confirmed in future research, it could be of great interest for oral use.
Collapse
Affiliation(s)
- Zahi Badran
- Department of Periodontology, Rmes Inserm U1229/UIC11, Faculty of Dental Surgery, Nantes, France
- Department of Oral Implantology, CHU-Faculty of Dental Surgery, Nantes, France
- Unit of Periodontology, Dental Institute, King's College, London, UK
| | - Xavier Struillou
- Department of Periodontology, Rmes Inserm U1229/UIC11, Faculty of Dental Surgery, Nantes, France
- Department of Oral Implantology, CHU-Faculty of Dental Surgery, Nantes, France
| | - Francis J Hughes
- Unit of Periodontology, Dental Institute, King's College, London, UK
| | - Assem Soueidan
- Department of Periodontology, Rmes Inserm U1229/UIC11, Faculty of Dental Surgery, Nantes, France
| | - Alain Hoornaert
- Department of Periodontology, Rmes Inserm U1229/UIC11, Faculty of Dental Surgery, Nantes, France
- Department of Oral Implantology, CHU-Faculty of Dental Surgery, Nantes, France
| | - Mark Ide
- Unit of Periodontology, Dental Institute, King's College, London, UK
| |
Collapse
|
34
|
Lecocq M, Felix MS, Bernard C, Linares JM, Chaves-Jacob J, Decherchi P, Dousset E. Biocompatibility of four common orthopedic biomaterials following neuroelectromyostimulation: An in-vivo study. J Biomed Mater Res B Appl Biomater 2017; 106:1156-1164. [PMID: 28556590 DOI: 10.1002/jbm.b.33927] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2016] [Revised: 04/25/2017] [Accepted: 05/12/2017] [Indexed: 11/10/2022]
Abstract
Despite the worldwide high prevalence of total joint arthroplasty (TJA), life expectancy of prosthesis remains limited by mechanical and chemical constraint which promote wear debris production, surrounding tissues damage and finally prosthesis loosening. Such results could be amplified by neuro-myoelectrostimulation (NMES; widely used to reduce neuromuscular deficits observed following TJA surgery). It was previously described in an in vivo experiment that interactions between NMES and Ti6Al4V implant are deleterious for both implant and surrounding muscles. The purpose of the present study was to compare the biocompatibility of four common orthopedic biomaterials, two metallic (Ti6Al4V, CrCo) and two nonmetallic (PEEK, Al2 O3 ) alloys, fixed on rat tibial crest in which the surrounding muscles were electrostimulated. Muscle cell death rate was not found significantly increased, with or without electrical stimulation for nonmetallic implants. Contrary to Ti6Al4V alloy, the CrCo implant did not induce destruction of the surrounding muscle. However, cell viability decreased for both metallic alloys when NMES was applied but within a greater significant extent for Ti6Al4V implant. Otherwise, when NMES was applied, implant-to-bone adhesion significantly decreased for Ti6Al4V while no significant difference was found for PEEK, Al2 O3 , and CrCo. Statistical analyses reveal also a lesser adhesion strength for Ti6Al4V compared with CrCo when NMES was applied. Selecting the most suitable material in term of biocompatibility remains a major concern and non-metallic materials seems to be more appropriated in regard to electrical currents used for post TJA care. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 1156-1164, 2018.
Collapse
Affiliation(s)
- Mathieu Lecocq
- Aix-Marseille Université, CNRS, Institut des Sciences du Mouvement: Etienne-Jules MAREY (UMR 7287), Equipe "Plasticité des Systèmes Nerveux et Musculaire" (PSNM), Faculté des Sciences du Sport, 13288 Marseille Cedex 09, France
| | - Marie-Solenne Felix
- Aix-Marseille Université, CNRS, Institut des Sciences du Mouvement: Etienne-Jules MAREY (UMR 7287), Equipe "Plasticité des Systèmes Nerveux et Musculaire" (PSNM), Faculté des Sciences du Sport, 13288 Marseille Cedex 09, France
| | - Cécile Bernard
- Aix-Marseille Université, CNRS, Institut des Sciences du Mouvement: Etienne-Jules MAREY (UMR 7287), Equipe "Plasticité des Systèmes Nerveux et Musculaire" (PSNM), Faculté des Sciences du Sport, 13288 Marseille Cedex 09, France
| | - Jean-Marc Linares
- Aix-Marseille Université, CNRS, Institut des Sciences du Mouvement: Etienne-Jules MAREY (UMR 7287), Equipe "Conception Bio-Inspirée" (CBI), IUT d'Aix-en-Provence, 13625 Aix-en-Provence Cedex, France
| | - Julien Chaves-Jacob
- Aix-Marseille Université, CNRS, Institut des Sciences du Mouvement: Etienne-Jules MAREY (UMR 7287), Equipe "Conception Bio-Inspirée" (CBI), IUT d'Aix-en-Provence, 13625 Aix-en-Provence Cedex, France
| | - Patrick Decherchi
- Aix-Marseille Université, CNRS, Institut des Sciences du Mouvement: Etienne-Jules MAREY (UMR 7287), Equipe "Plasticité des Systèmes Nerveux et Musculaire" (PSNM), Faculté des Sciences du Sport, 13288 Marseille Cedex 09, France
| | - Erick Dousset
- Aix-Marseille Université, CNRS, Institut des Sciences du Mouvement: Etienne-Jules MAREY (UMR 7287), Equipe "Plasticité des Systèmes Nerveux et Musculaire" (PSNM), Faculté des Sciences du Sport, 13288 Marseille Cedex 09, France
| |
Collapse
|
35
|
Roy M, Pompella A, Kubacki J, Piosik A, Psiuk B, Klimontko J, Szade J, Roy RA, Hedzelek W. Photofunctionalization of dental zirconia oxide: Surface modification to improve bio-integration preserving crystal stability. Colloids Surf B Biointerfaces 2017; 156:194-202. [PMID: 28531876 DOI: 10.1016/j.colsurfb.2017.05.031] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2017] [Revised: 05/09/2017] [Accepted: 05/10/2017] [Indexed: 10/19/2022]
Abstract
The use of zirconium oxide in dental implantology is rapidly increasing as it is regarded as being more aesthetical and biologically friendly than titanium oxide. The interaction of titanium oxide with cells and proteins has proven to be significantly affected by the inevitable atmospheric hydrocarbon contamination, defined as biological ageing. The latter has proven to be effectively reversed by UVC irradiation. Crystal structures of both Zr and Ti oxides are very similar, thus also ZrO2 is prone to contamination by hydrocarbons. In the present study we have characterized the chemical-physical changes occurring to ZrO2 after UVC irradiation. Firstly a reduction by 3-fold of carbon present on its surface. XRD analysis has indicated that UVC irradiation treatment does not affect the crystalline structure of ZrO2, suggesting that it is possible to improve cell attachment on the surface without sacrificing the mechanical strength of the material. In addition a chemical model of interaction of cell surface proteins with the almost carbon free ZrO2 surface obtainable after UVC irradiation is proposed, pointing to the important role likely played by integrins and RGD sequences originating in soluble proteins adsorbed at the cell/ZrO2 interface. Hence in clinical practice UVC photofunctionalization could improve the soft tissue seal around dental implants functioning as a valid barrier between implant and peri-implant bone, thereby improving the long-term success of implants.
Collapse
Affiliation(s)
- Marco Roy
- Prosthodontic Department, Poznan University of Medical Science, Ul. Bukowska 70, 60-812 Poznan, Poland.
| | - Alfonso Pompella
- Dept. of Translational Research and New Technologies in Medicine and Surgery, University of Pisa Medical School, Via Roma 55, 56126 Pisa, Italy
| | - Jerzy Kubacki
- A. Chelkowski Institute of Physics, University of Silesia, Uniwersytecka 4, 40-007 Katowice, Poland; Silesian Center for Education and Interdisciplinary Research, 75 Pulku Piechoty 1A, 41-500 Chorzów, Poland
| | - Adam Piosik
- Prosthodontic Department, Poznan University of Medical Science, Ul. Bukowska 70, 60-812 Poznan, Poland
| | - Bronisław Psiuk
- Refractory Materials Division,Institute of Ceramics and Building Materials, Toszecka 99, 44-100 Gliwice, Poland
| | - Joanna Klimontko
- A. Chelkowski Institute of Physics, University of Silesia, Uniwersytecka 4, 40-007 Katowice, Poland; Silesian Center for Education and Interdisciplinary Research, 75 Pulku Piechoty 1A, 41-500 Chorzów, Poland
| | - Jacek Szade
- A. Chelkowski Institute of Physics, University of Silesia, Uniwersytecka 4, 40-007 Katowice, Poland; Silesian Center for Education and Interdisciplinary Research, 75 Pulku Piechoty 1A, 41-500 Chorzów, Poland
| | | | - Wieslaw Hedzelek
- Prosthodontic Department, Poznan University of Medical Science, Ul. Bukowska 70, 60-812 Poznan, Poland
| |
Collapse
|
36
|
Brunot-Gohin C, Duval JL, Verbeke S, Belanger K, Pezron I, Kugel G, Laurent-Maquin D, Gangloff S, Egles C. Biocompatibility study of lithium disilicate and zirconium oxide ceramics for esthetic dental abutments. J Periodontal Implant Sci 2016; 46:362-371. [PMID: 28050314 PMCID: PMC5200862 DOI: 10.5051/jpis.2016.46.6.362] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2016] [Accepted: 10/21/2016] [Indexed: 12/03/2022] Open
Abstract
Purpose The increasing demand for esthetically pleasing results has contributed to the use of ceramics for dental implant abutments. The aim of this study was to compare the biological response of epithelial tissue cultivated on lithium disilicate (LS2) and zirconium oxide (ZrO2) ceramics. Understanding the relevant physicochemical and mechanical properties of these ceramics will help identify the optimal material for facilitating gingival wound closure. Methods Both biomaterials were prepared with 2 different surface treatments: raw and polished. Their physicochemical characteristics were analyzed by contact angle measurements, scanning white-light interferometry, and scanning electron microscopy. An organotypic culture was then performed using a chicken epithelium model to simulate peri-implant soft tissue. We measured the contact angle, hydrophobicity, and roughness of the materials as well as the tissue behavior at their surfaces (cell migration and cell adhesion). Results The best cell migration was observed on ZrO2 ceramic. Cell adhesion was also drastically lower on the polished ZrO2 ceramic than on both the raw and polished LS2. Evaluating various surface topographies of LS2 showed that increasing surface roughness improved cell adhesion, leading to an increase of up to 13%. Conclusions Our results demonstrate that a biomaterial, here LS2, can be modified using simple surface changes in order to finely modulate soft tissue adhesion. Strong adhesion at the abutment associated with weak migration assists in gingival wound healing. On the same material, polishing can reduce cell adhesion without drastically modifying cell migration. A comparison of LS2 and ZrO2 ceramic showed that LS2 was more conducive to creating varying tissue reactions. Our results can help dental surgeons to choose, especially for esthetic implant abutments, the most appropriate biomaterial as well as the most appropriate surface treatment to use in accordance with specific clinical dental applications.
Collapse
Affiliation(s)
- Céline Brunot-Gohin
- Laboratory of Biomaterials and Bone Site Inflammation, University of Reims Champagne-Ardenne, Reims, France.; Laboratory of Biomechanics and Bioengineering, Research Center of Royallieu, University of Technology of Compiègne, Sorbonne Universities, Compiègne, France.; University of Reims Champagne-Ardenne, Faculty of Odontology, Reims, France
| | - Jean-Luc Duval
- Laboratory of Biomechanics and Bioengineering, Research Center of Royallieu, University of Technology of Compiègne, Sorbonne Universities, Compiègne, France
| | - Sandra Verbeke
- University of Reims Champagne-Ardenne, Faculty of Odontology, Reims, France
| | - Kayla Belanger
- Laboratory of Biomechanics and Bioengineering, Research Center of Royallieu, University of Technology of Compiègne, Sorbonne Universities, Compiègne, France
| | - Isabelle Pezron
- Laboratory of Integrated Renewable Matter Transformations, Research Center of Royallieu, University of Technology of Compiègne, Sorbonne Universities, Compiègne, France
| | - Gérard Kugel
- Tufts University School of Dental Medicine, Boston, MA, USA
| | - Dominique Laurent-Maquin
- Laboratory of Biomaterials and Bone Site Inflammation, University of Reims Champagne-Ardenne, Reims, France.; University of Reims Champagne-Ardenne, Faculty of Odontology, Reims, France
| | - Sophie Gangloff
- Laboratory of Biomaterials and Bone Site Inflammation, University of Reims Champagne-Ardenne, Reims, France
| | - Christophe Egles
- Laboratory of Biomechanics and Bioengineering, Research Center of Royallieu, University of Technology of Compiègne, Sorbonne Universities, Compiègne, France.; Tufts University School of Dental Medicine, Boston, MA, USA
| |
Collapse
|
37
|
Smeets R, Schöllchen M, Gauer T, Aarabi G, Assaf AT, Rendenbach C, Beck-Broichsitter B, Semmusch J, Sedlacik J, Heiland M, Fiehler J, Siemonsen S. Artefacts in multimodal imaging of titanium, zirconium and binary titanium-zirconium alloy dental implants: an in vitro study. Dentomaxillofac Radiol 2016; 46:20160267. [PMID: 27910719 DOI: 10.1259/dmfr.20160267] [Citation(s) in RCA: 46] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
OBJECTIVES To analyze and evaluate imaging artefacts induced by zirconium, titanium and titanium-zirconium alloy dental implants. METHODS Zirconium, titanium and titanium-zirconium alloy implants were embedded in gelatin and MRI, CT and CBCT were performed. Standard protocols were used for each modality. For MRI, line-distance profiles were plotted to quantify the accuracy of size determination. For CT and CBCT, six shells surrounding the implant were defined every 0.5 cm from the implant surface and histogram parameters were determined for each shell. RESULTS While titanium and titanium-zirconium alloy induced extensive signal voids in MRI owing to strong susceptibility, zirconium implants were clearly definable with only minor distortion artefacts. For titanium and titanium-zirconium alloy, the MR signal was attenuated up to 14.1 mm from the implant. In CT, titanium and titanium-zirconium alloy resulted in less streak artefacts in comparison with zirconium. In CBCT, titanium-zirconium alloy induced more severe artefacts than zirconium and titanium. CONCLUSIONS MRI allows for an excellent image contrast and limited artefacts in patients with zirconium implants. CT and CBCT examinations are less affected by artefacts from titanium and titanium-zirconium alloy implants compared with MRI. The knowledge about differences of artefacts through different implant materials and image modalities might help support clinical decisions for the choice of implant material or imaging device in the clinical setting.
Collapse
Affiliation(s)
- Ralf Smeets
- 1 Department of Oral and Maxillofacial Surgery, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Maximilian Schöllchen
- 1 Department of Oral and Maxillofacial Surgery, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Tobias Gauer
- 2 Department of Radiotherapy and Radiation Oncology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Ghazal Aarabi
- 3 Department of Prosthetic Dentistry, Center for Dental and Oral Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Alexandre T Assaf
- 1 Department of Oral and Maxillofacial Surgery, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Carsten Rendenbach
- 1 Department of Oral and Maxillofacial Surgery, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Benedicta Beck-Broichsitter
- 1 Department of Oral and Maxillofacial Surgery, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Jan Semmusch
- 1 Department of Oral and Maxillofacial Surgery, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Jan Sedlacik
- 4 Department of Diagnostic and Interventional Neuroradiology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Max Heiland
- 1 Department of Oral and Maxillofacial Surgery, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Jens Fiehler
- 4 Department of Diagnostic and Interventional Neuroradiology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Susanne Siemonsen
- 4 Department of Diagnostic and Interventional Neuroradiology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| |
Collapse
|
38
|
Abd El-Ghany OS, Sherief AH. Zirconia based ceramics, some clinical and biological aspects: Review. ACTA ACUST UNITED AC 2016. [DOI: 10.1016/j.fdj.2016.10.002] [Citation(s) in RCA: 110] [Impact Index Per Article: 13.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
39
|
Kim S, Park C, Moon BS, Kim HE, Jang TS. Enhancement of osseointegration by direct coating of rhBMP-2 on target-ion induced plasma sputtering treated SLA surface for dental application. J Biomater Appl 2016; 31:807-818. [DOI: 10.1177/0885328216679761] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Owing to the excellent bioactive properties of recombinant human bone morphogenetic proteins (rhBMPs), dentistry considers them as a fascinating adjuvant alternative for enhancing bone regeneration and bone-to-implant junction in the early implantation stages. However, stable loading and delivery efficiency of rhBMPs on the implant surfaces involve major concerns because of the harsh wearing condition under load during implantation. In this study, to achieve successful rhBMP-2 delivery, a nanoporous surface structure is introduced on the sandblasting with large grit and acid-etching (SLA)-treated titanium (Ti) surface via the tantalum (Ta) target-ion induced plasma sputtering (TIPS) technique. Unlike oxidation-induced surface nanoporous fabrications on a Ti surface, TIPS-treated surfaces provide excellent structural unity of the nanoporous structure with the substrate due to their etching-based fabrication mechanism. SLA/TIPS-treated Ti exhibits distinct nanoporous structures on the microscale surface geometry and better hydrophilicity compared with SLA-treated Ti. A sufficiently empty nanoporous surface structure combined with the hydrophilic property of SLA/TIPS-treated Ti facilitates the formation of a thick and uniform coating layer of rhBMP-2 on the surface without any macro- and microcoagulation. Compared with the SLA-treated Ti surface, the amount of coated rhBMP-2 increases up to 63% on the SLA/TIPS-treated Ti surface. As a result, the in vitro pre-osteoblast cell response of the SLA/TIPS-treated Ti surface, especially cell adhesion and differentiation behaviors, improves remarkably. A bone-regenerating direct comparison between the rhBMP-2-coated SLA-treated and SLA/TIPS-treated Ti is conducted on a defective dog mandible model. After 8 weeks of implantation surgery, SLA/TIPS-treated Ti with rhBMP-2 exhibits a better degree of contact area for the implanted bone, which mineralizes new bones around the implant. Quantitative results of bone-in-contact ratio and new bone volume also show significantly higher values for the SLA/TIPS-treated Ti with the rhBMP-2 specimen. These results confirm that an SLA/TIPS-treated surface is a suitable rhBMP-2 carrier for a dental implant to achieve early and strong osseointegration of Ti dental implants.
Collapse
Affiliation(s)
- Sungwon Kim
- Department of Materials Science and Engineering, Seoul National University, Gwanak-gu, Seoul, Korea
| | - Cheonil Park
- Department of Materials Science and Engineering, Seoul National University, Gwanak-gu, Seoul, Korea
| | - Byeong-Seok Moon
- Department of Materials Science and Engineering, Seoul National University, Gwanak-gu, Seoul, Korea
| | - Hyoun-Ee Kim
- Department of Materials Science and Engineering, Seoul National University, Gwanak-gu, Seoul, Korea
| | - Tae-Sik Jang
- Department of Materials Science and Engineering, Seoul National University, Gwanak-gu, Seoul, Korea
| |
Collapse
|
40
|
Mestres G, Espanol M, Xia W, Tenje M, Ott M. Evaluation of Biocompatibility and Release of Reactive Oxygen Species of Aluminum Oxide-Coated Materials. ACS OMEGA 2016; 1:706-713. [PMID: 30023487 PMCID: PMC6044712 DOI: 10.1021/acsomega.6b00198] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/17/2016] [Accepted: 10/04/2016] [Indexed: 06/07/2023]
Abstract
Surface properties of biomaterials can strongly influence biomaterial-host interactions. For this reason, coating processes open a wide range of possibilities to modulate the fate of a biomaterial in the body. This study evaluates the effect of a coating material intended for drug delivery capsules on biocompatibility and the release of reactive oxygen species (ROS), that is, respiratory burst in macrophages that indicates acute inflammation. In parallel with a new approach to develop drug-delivery capsules by directly coating solid-state drug particles, in this study, glass slides and silicon nanoparticles (NPs) were coated with aluminum oxide (Al2O3) using atomic layer deposition. Different sizes of NPs (20 and 310 nm) were suspended at different concentrations (10, 100, and 1000 μg/mL) and were evaluated. The homogeneous coating of slides was proved using X-ray photoelectron spectroscopy, and the coating on NP was observed using transmission electron microscopy. Human dermal fibroblasts and human osteoblasts were able to proliferate on the coated slides and in the presence of a suspension of coated NPs (20 and 310 nm) at a low concentration (10 μg/mL). The macrophages released ROS only when in contact with NPs at a concentration of 1000 μg/mL, where the 20 nm NPs caused a higher release of ROS than the 310 nm NPs. This study shows that Al2O3 coatings do not affect the cells negatively and that the cell viability was compromised only when in contact with a high concentration (1000 μg/mL) of smaller (20 nm) NPs.
Collapse
Affiliation(s)
- Gemma Mestres
- Department
of Engineering Sciences, Uppsala University, Box 534, 751 21 Uppsala, Sweden
| | - Montserrat Espanol
- Department
of Engineering Sciences and Metallurgy, Technical University of Catalonia, Diagonal
647, 08028 Barcelona, Spain
| | - Wei Xia
- Department
of Engineering Sciences, Uppsala University, Box 534, 751 21 Uppsala, Sweden
| | - Maria Tenje
- Department
of Engineering Sciences, Uppsala University, Box 534, 751 21 Uppsala, Sweden
- Department
of Biomedical Engineering, Lund University, Box 118, 221 00 Lund, Sweden
- Science
for Life Laboratory, Box 1031, 171 21 Solna, Sweden
| | - Marjam Ott
- Department
of Engineering Sciences, Uppsala University, Box 534, 751 21 Uppsala, Sweden
- Science
for Life Laboratory, Box 1031, 171 21 Solna, Sweden
| |
Collapse
|
41
|
Kang H, Yan Y, Jia P, Yang K, Guo C, Chen H, Qi J, Qian N, Xu X, Wang F, Li C, Guo L, Deng L. Desferrioxamine reduces ultrahigh-molecular-weight polyethylene-induced osteolysis by restraining inflammatory osteoclastogenesis via heme oxygenase-1. Cell Death Dis 2016; 7:e2435. [PMID: 27787522 PMCID: PMC5133998 DOI: 10.1038/cddis.2016.339] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2016] [Revised: 09/13/2016] [Accepted: 09/23/2016] [Indexed: 12/11/2022]
Abstract
As wear particles-induced osteolysis still remains the leading cause of early implant loosening in endoprosthetic surgery, and promotion of osteoclastogenesis by wear particles has been confirmed to be responsible for osteolysis. Therapeutic agents targeting osteoclasts formation are considered for the treatment of wear particles-induced osteolysis. In the present study, we demonstrated for the first time that desferrioxamine (DFO), a powerful iron chelator, could significantly alleviate osteolysis in an ultrahigh-molecular-weight polyethylene (UHMWPE) particles-induced mice calvaria osteolysis model. Furthermore, DFO attenuated calvaria osteolysis by restraining enhanced inflammatory osteoclastogenesis induced by UHMWPE particles. Consistent with the in vivo results, we found DFO was also able to inhibit osteoclastogenesis in a dose-dependent manner in vitro, as evidenced by reduction of osteoclasts formation and suppression of osteoclast specific genes expression. In addition, DFO dampened osteoclasts differentiation and formation at early stage but not at late stage. Mechanistically, the reduction of osteoclastogenesis by DFO was due to increased heme oxygenase-1 (HO-1) expression, as decreased osteoclasts formation induced by DFO was significantly restored after HO-1 was silenced by siRNA, while HO-1 agonist COPP treatment enhanced DFO-induced osteoclastogenesis inhibition. In addition, blocking of p38 mitogen-activated protein kinase (p38MAPK) signaling pathway promoted DFO-induced HO-1 expression, implicating that p38 signaling pathway was involved in DFO-mediated HO-1 expression. Taken together, our results suggested that DFO inhibited UHMWPE particles-induced osteolysis by restraining inflammatory osteoclastogenesis through upregulation of HO-1 via p38MAPK pathway. Thus, DFO might be used as an innovative and safe therapeutic alternative for treating wear particles-induced aseptic loosening.
Collapse
Affiliation(s)
- Hui Kang
- Shanghai Key Laboratory for Bone and Joint Diseases, Shanghai Institute of Orthopaedics and Traumatology, Shanghai Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China
| | - Yufei Yan
- Shanghai Key Laboratory for Bone and Joint Diseases, Shanghai Institute of Orthopaedics and Traumatology, Shanghai Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China
| | - Peng Jia
- Department of Orthopaedics, The Second Affiliated Hospital of Soochow University, Suzhou, Jiangsu Province, China
| | - Kai Yang
- Shanghai Key Laboratory for Bone and Joint Diseases, Shanghai Institute of Orthopaedics and Traumatology, Shanghai Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China
| | - Changjun Guo
- Shanghai Key Laboratory for Bone and Joint Diseases, Shanghai Institute of Orthopaedics and Traumatology, Shanghai Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China
| | - Hao Chen
- Shanghai Key Laboratory for Bone and Joint Diseases, Shanghai Institute of Orthopaedics and Traumatology, Shanghai Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China
| | - Jin Qi
- Shanghai Key Laboratory for Bone and Joint Diseases, Shanghai Institute of Orthopaedics and Traumatology, Shanghai Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China
| | - Niandong Qian
- Shanghai Key Laboratory for Bone and Joint Diseases, Shanghai Institute of Orthopaedics and Traumatology, Shanghai Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China
| | - Xing Xu
- Shanghai Key Laboratory for Bone and Joint Diseases, Shanghai Institute of Orthopaedics and Traumatology, Shanghai Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China
| | - Fei Wang
- Shanghai Key Laboratory for Bone and Joint Diseases, Shanghai Institute of Orthopaedics and Traumatology, Shanghai Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China
| | - Changwei Li
- Shanghai Key Laboratory for Bone and Joint Diseases, Shanghai Institute of Orthopaedics and Traumatology, Shanghai Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China
| | - Lei Guo
- Shanghai Key Laboratory for Bone and Joint Diseases, Shanghai Institute of Orthopaedics and Traumatology, Shanghai Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China
| | - Lianfu Deng
- Shanghai Key Laboratory for Bone and Joint Diseases, Shanghai Institute of Orthopaedics and Traumatology, Shanghai Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China
| |
Collapse
|
42
|
Neuerburg C, Loer T, Mittlmeier L, Polan C, Farkas Z, Holdt LM, Utzschneider S, Schwiesau J, Grupp TM, Böcker W, Aszodi A, Wedemeyer C, Kammerlander C. Impact of vitamin E-blended UHMWPE wear particles on the osseous microenvironment in polyethylene particle-induced osteolysis. Int J Mol Med 2016; 38:1652-1660. [PMID: 27779642 PMCID: PMC5117748 DOI: 10.3892/ijmm.2016.2780] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2016] [Accepted: 09/23/2016] [Indexed: 12/29/2022] Open
Abstract
Aseptic loosening mediated by wear particle-induced osteolysis (PIO) remains the major cause of implant loosening in endoprosthetic surgery. The development of new vitamin E (α-tocopherol)-blended ultra-high molecular weight polyethylene (VE-UHMWPE) with increased oxidation resistance and improved mechanical properties has raised hopes. Furthermore, regenerative approaches may be opened, as vitamin E supplementation has shown neuroprotective characteristics mediated via calcitonin gene-related peptide (CGRP), which is known to affect bone remodeling in PIO. Therefore, the present study aimed to further clarify the impact of VE-UHMWPE wear particles on the osseous microenvironment and to identify the potential modulatory pathways involved. Using an established murine calvaria model, mice were subjected to sham operation (SHAM group), or treated with UHMWPE or VE-UHMWPE particles for different experimental durations (7, 14 and 28 days; n=6/group). Morphometric analysis by micro-computed tomography detected significant (p<0.01) and comparable signs of PIO in all particle-treated groups, whereas markers of inflammation [tumor necrosis factor (TNF)-α/tartrate resistant acid phosphatase (TRAP) staining] and bone remodeling [Dickkopf-related protein 1 (DKK-1)/osteoprotegerin (OPG)] were most affected in the early stages following surgery. Taking the present data into account, VE-UHMWPE appears to have a promising biocompatibility and increased ageing resistance. According to the α-CGRP serum levels and immunohistochemistry, the impact of vitamin E on neuropeptidergic signaling and its chance for regenerative approaches requires further investigation.
Collapse
Affiliation(s)
- Carl Neuerburg
- Experimental Surgery and Regenerative Medicine, Department of General, Trauma and Reconstructive Surgery, Munich University Hospital LMU, Munich, Germany
| | - Theresa Loer
- Department of Orthopedics and Trauma Surgery, University Hospital, University of Duisburg-Essen, Essen, Germany
| | - Lena Mittlmeier
- Experimental Surgery and Regenerative Medicine, Department of General, Trauma and Reconstructive Surgery, Munich University Hospital LMU, Munich, Germany
| | - Christina Polan
- Department of Orthopedics and Trauma Surgery, University Hospital, University of Duisburg-Essen, Essen, Germany
| | - Zsuzsanna Farkas
- Experimental Surgery and Regenerative Medicine, Department of General, Trauma and Reconstructive Surgery, Munich University Hospital LMU, Munich, Germany
| | - Lesca Miriam Holdt
- Institute of Laboratory Medicine, Ludwig-Maximilians-University Munich, Munich, Germany
| | - Sandra Utzschneider
- Department of Orthopaedic Surgery, Physical Medicine and Rehabilitation, Munich University Hospital LMU, Munich, Germany
| | - Jens Schwiesau
- Department of Orthopaedic Surgery, Physical Medicine and Rehabilitation, Munich University Hospital LMU, Munich, Germany
| | - Thomas M Grupp
- Department of Orthopaedic Surgery, Physical Medicine and Rehabilitation, Munich University Hospital LMU, Munich, Germany
| | - Wolfgang Böcker
- Experimental Surgery and Regenerative Medicine, Department of General, Trauma and Reconstructive Surgery, Munich University Hospital LMU, Munich, Germany
| | - Attila Aszodi
- Experimental Surgery and Regenerative Medicine, Department of General, Trauma and Reconstructive Surgery, Munich University Hospital LMU, Munich, Germany
| | - Christian Wedemeyer
- KKEL St. Barbara Hospital, Department of Orthopedics and Trauma Surgery, Gladbeck, Germany
| | - Christian Kammerlander
- Experimental Surgery and Regenerative Medicine, Department of General, Trauma and Reconstructive Surgery, Munich University Hospital LMU, Munich, Germany
| |
Collapse
|
43
|
Cossellu G, Motta V, Dioni L, Angelici L, Vigna L, Farronato G, Pesatori AC, Bollati V. Titanium and Zirconium Levels Are Associated with Changes in MicroRNAs Expression: Results from a Human Cross-Sectional Study on Obese Population. PLoS One 2016; 11:e0161916. [PMID: 27611787 PMCID: PMC5017677 DOI: 10.1371/journal.pone.0161916] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2016] [Accepted: 08/15/2016] [Indexed: 11/21/2022] Open
Abstract
Objectives In this study on 90 individuals we aimed at evaluating the microRNAs (miRNAs) expression profile associated with personal levels of Titanium (Ti) and Zirconium (Zr) traced in hair samples. Ti and Zr materials are broadly used for dental implants but the biological reactions triggered by a long term presence of these materials in the oral cavity still need to be assessed. MiRNAs are mechanisms that need to be investigated as they play a fundamental role in the control of gene expression following external stimuli and contribute to a wide range of pathophysiological processes. Methods Using the TaqMan® Low-Density Array, we assessed the expression levels of 377 human miRNAs in peripheral blood of 90 subjects. Hair samples were analyzed for Ti and Zr content using Inductively Coupled Plasma-Mass Spectrometry. We performed multivariable regression analysis to investigate the effects of Ti and Zr exposure on miRNA expression levels. We used the Ingenuity Pathway Analysis (IPA) software to explore the functional role of the investigated miRNAs and the related target genes. Results Seven miRNAs (miR-99b, miR-142-5p, miR-152, miR-193a-5p, miR-323-3p, miR-335, miR-494) resulted specifically associated with Zr levels. The functional target analysis showed that miRNAs are involved in mechanisms such as inflammation, skeletal and connective tissue disorders. Conclusions Our data suggest that Zr is more bioactive than Ti and show that miRNAs are relevant molecular mechanisms sensitive to Zr exposure.
Collapse
Affiliation(s)
- Gianguido Cossellu
- Department of Biomedical, Surgical and Dental Sciences, Fondazione IRCCS Cà Granda, Ospedale Maggiore Policlinico, Università degli Studi di Milano, Via della Commenda 10, 20122, Milan, Italy
- * E-mail:
| | - Valeria Motta
- EPIGET - Epidemiology, Epigenetics and Toxicology Lab, Department of Clinical Sciences and Community Health, Università degli Studi di Milano, Milan, Italy
| | - Laura Dioni
- EPIGET - Epidemiology, Epigenetics and Toxicology Lab, Department of Clinical Sciences and Community Health, Università degli Studi di Milano, Milan, Italy
| | - Laura Angelici
- EPIGET - Epidemiology, Epigenetics and Toxicology Lab, Department of Clinical Sciences and Community Health, Università degli Studi di Milano, Milan, Italy
| | - Luisella Vigna
- Worker’s Health Protection and Promotion Unit, Fondazione IRCCS Ca’ Granda Ospedale Maggiore Policlinico, Milan, Italy
| | - Giampietro Farronato
- Department of Biomedical, Surgical and Dental Sciences, Fondazione IRCCS Cà Granda, Ospedale Maggiore Policlinico, Università degli Studi di Milano, Via della Commenda 10, 20122, Milan, Italy
| | - Angela Cecilia Pesatori
- EPIGET - Epidemiology, Epigenetics and Toxicology Lab, Department of Clinical Sciences and Community Health, Università degli Studi di Milano, Milan, Italy
- Worker’s Health Protection and Promotion Unit, Fondazione IRCCS Ca’ Granda Ospedale Maggiore Policlinico, Milan, Italy
- Epidemiology Unit, Fondazione IRCCS Ca’ Granda Ospedale Maggiore Policlinico, Milan, Italy
| | - Valentina Bollati
- EPIGET - Epidemiology, Epigenetics and Toxicology Lab, Department of Clinical Sciences and Community Health, Università degli Studi di Milano, Milan, Italy
| |
Collapse
|
44
|
Sá MJC, Rezende CMF, Silva Junior VA, Garcia HC, Griffon DJ, Silva VV. In Vivo Behavior of Zirconia—Hydroxyapatite (ZH) Ceramic Implants in Dogs: A Clinical, Radiographic, and Histological Study. J Biomater Appl 2016; 22:5-31. [PMID: 17690118 DOI: 10.1177/0885328206065860] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
The main goal of this study is to evaluate potential applications of two zirconia—hydroxyapatite composites, Z4H6 and Z6H4, as bone substitutes. Composite plugs were implanted into the distal femoral metaphysis and also onto the longissimus dorsi of 18 adult mixed-breed dogs in order to assess in vivo biocompatibility by immediate clinical and radiographic evaluation 30, 90, and 120 days after implantation. Radiographic examination revealed radiolucency on the defect site. However, a progressive increase in bone density was observed over time, reaching a radiopacity similar to that of bone 120 days after implantation. Histological study revealed that a thin layer of fibroblasts was observed at the implant—bone interface in addition to osteoblastic activity 30 days after implantation, whereas bone neoformation around the implants was detected for the subsequent implantation times (90 and 120 days). Otherwise, the histological evaluation of the implant—muscle interface showed the presence of an initially thick fibrous tissue layer 30 days after implantation, which decreased with longer investigation times (90 and 120 days). The numbers of plasmocytes, lymphocytes, and macrophages gradually reduced as a function implantation time, being completely absent 120 days after implantation with a resulting complete osteointegration process. The zirconia phase content did not affect the bioactive behavior of the implants investigated and did not induce bone formation when implanted into muscle either.
Collapse
Affiliation(s)
- M J C Sá
- School of Veterinary, Federal University of Minas Gerais State Av Antônio Carlos, 6627, CP 567, Pampulha CEP 30161-970, Belo Horizonte, MG, Brazil
| | | | | | | | | | | |
Collapse
|
45
|
Shang JYZ, Zhan P, Jiang C, Zou Y, Liu H, Zhang B, Dai M. Inhibitory Effects of Lanthanum Chloride on Wear Particle-Induced Osteolysis in a Mouse Calvarial Model. Biol Trace Elem Res 2016; 169:303-9. [PMID: 26105543 DOI: 10.1007/s12011-015-0364-x] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/15/2015] [Accepted: 05/04/2015] [Indexed: 11/26/2022]
Abstract
Osteolysis is a bone disorder associated with progressive destruction of bone tissues. However, the effects of lanthanum chloride (LaCl3) on osteolysis remain unknown. Therefore, the aim of this study was to determine the effects of LaCl3 on osteolysis in vivo. In a mouse calvarial model, C57BL/6J mice were injected with wear particles with or without LaCl3. Microcomputed tomography, hematoxylin and eosin staining, and tartrate-resistant acid phosphatase staining were performed for the pathological characterization of calvariae, and eight calvariae per group were prepared for the assay of TNF-α, IL-1β, and RANKL secretion using quantitative enzyme-linked immunosorbent assay (ELISA). In mice treated with high-dose LaCl3, particle-induced osteolysis and inflammatory reaction were reduced compared with that in the vehicle-treated control. Moreover, treatment with high-dose LaCl3 suppressed the wear particle-induced decrease in bone mineral content, bone mineral density, and bone volume fraction. Bone destruction and resorption were higher in the LaCl3-treated group than in the saline-treated group but lower than those in the wear particle group. Finally, our results showed that treatment with a high dose of LaCl3 suppressed osteoclastogenesis. Thus, LaCl3 may represent a novel therapeutic agent for the treatment or prevention of wear particle-induced osteolysis and aseptic loosening.
Collapse
Affiliation(s)
- Jiang-Yin-Zi Shang
- Department of Orthopedics, The First Affiliated Hospital, Nanchang University, Nanchang, Jiangxi, China
| | - Ping Zhan
- Department of Orthopedics, The First Affiliated Hospital, Nanchang University, Nanchang, Jiangxi, China
| | - Chuan Jiang
- Shanghai Key Laboratory of Orthopedic Implant, Department of Orthopedic Surgery, Shanghai Ninth People's Hospital, Shangai Jiao Tong University School of Medicine, Shanghai, China
| | - Yang Zou
- The Chinese People's Liberation Army 94th Hospital, Nanchang, Jiangxi, China
| | - Hucheng Liu
- Department of Orthopedics, The First Affiliated Hospital, Nanchang University, Nanchang, Jiangxi, China
| | - Bin Zhang
- Department of Orthopedics, The First Affiliated Hospital, Nanchang University, Nanchang, Jiangxi, China
| | - Min Dai
- Department of Orthopedics, The First Affiliated Hospital, Nanchang University, Nanchang, Jiangxi, China.
| |
Collapse
|
46
|
McGrory BJ, MacKenzie J, Babikian G. A High Prevalence of Corrosion at the Head-Neck Taper with Contemporary Zimmer Non-Cemented Femoral Hip Components. J Arthroplasty 2015; 30:1265-8. [PMID: 25737386 DOI: 10.1016/j.arth.2015.02.019] [Citation(s) in RCA: 101] [Impact Index Per Article: 11.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/22/2014] [Revised: 02/09/2015] [Accepted: 02/12/2015] [Indexed: 02/01/2023] Open
Abstract
Mechanically assisted crevice corrosion (MACC) occurs at metal/metal modular junctions in which at least one of the components is fabricated from cobalt-chromium alloy and may lead to adverse local tissue reaction (ALTR) in patients with metal-on-polyethylene (MoP) total hip arthroplasty. This type of reaction has been previously described in hips with head/neck modularity, but the prevalence is unknown. We found a prevalence of 1.1 percent in a consecutive series of 1356 contemporary Zimmer non-cemented femoral hip components followed for a minimum of 2years. The average time to presentation was 3.7years (range, 9-105months); delay in treatment led to irreversible soft tissue damage in three patients. We recommend usage of ceramic heads until this problem is further understood.
Collapse
Affiliation(s)
- Brian J McGrory
- Tufts University School of Medicine, Boston, Massachusetts; Maine Joint Replacement Institute, Portland, Maine; Maine Medical Center Division of Joint Replacements, Falmouth, Maine.
| | - Johanna MacKenzie
- Maine Medical Center Division of Joint Replacements, Falmouth, Maine
| | - George Babikian
- Tufts University School of Medicine, Boston, Massachusetts; Maine Joint Replacement Institute, Portland, Maine; Maine Medical Center Division of Joint Replacements, Falmouth, Maine
| |
Collapse
|
47
|
Zandparsa R, Albosefi A. An In Vitro Comparison of Fracture Load of Zirconia Custom Abutments with Internal Connection and Different Angulations and Thicknesses: Part II. J Prosthodont 2015; 25:151-5. [DOI: 10.1111/jopr.12292] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/15/2014] [Indexed: 12/01/2022] Open
Affiliation(s)
- Roya Zandparsa
- Department of Prosthodontics and Operative Dentistry, Prosthodontics Division and Advanced Education in Esthetic Dentistry; Tufts University School of Dental Medicine; Boston MA
| | - Abdalah Albosefi
- Department of Prosthodontics and Operative Dentistry, Prosthodontics Division and Advanced Education in Esthetic Dentistry; Tufts University School of Dental Medicine; Boston MA
| |
Collapse
|
48
|
Khan H, Hurworth M, Kop A. Metallosis following a dual coat porous hydroxyapatite shoulder hemiarthroplasty. J Orthop 2015; 12:266-71. [PMID: 26566331 DOI: 10.1016/j.jor.2015.02.005] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/20/2015] [Accepted: 02/01/2015] [Indexed: 11/16/2022] Open
Abstract
We report a case of metallosis following a shoulder hemiarthroplasty with a humeral component resurfacing shoulder replacement.
Collapse
Affiliation(s)
- Humza Khan
- Royal Perth Hospital, Western Australia, Australia
| | | | - Alan Kop
- Royal Perth Hospital, Western Australia, Australia
| |
Collapse
|
49
|
Dubey AK, Thrivikraman G, Basu B. Absence of systemic toxicity in mouse model towards BaTiO3 nanoparticulate based eluate treatment. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2015; 26:103. [PMID: 25655497 DOI: 10.1007/s10856-015-5414-6] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/17/2014] [Accepted: 10/24/2014] [Indexed: 06/04/2023]
Abstract
One of the existing issues in implant failure of orthopedic biomaterials is the toxicity induced by the fine particles released during long term use in vivo, leading to acute inflammatory response. In developing a new class of piezobiocomposite to mimic the integrated electrical and mechanical properties of bone, bone-mimicking physical properties as well as in vitro cytocompatibility properties have been achieved with spark plasma sintered hydroxyapatite (HA)-barium titanate (BaTiO3) composites. However, the presence of BaTiO3 remains a concern towards the potential toxicity effect. To address this issue, present work reports the first result to conclusively confirm the non-toxic effect of HA-BaTiO3 piezobiocomposite nanoparticulates, in vivo. Twenty BALB/c mice were intra-articularly injected at their right knee joints with different concentrations of HA-BaTiO3 composite of up to 25 mg/ml. The histopathological examination confirmed the absence of any trace of injected particles or any sign of inflammatory reaction in the vital organs, such as heart, spleen, kidney and liver at 7 days post-exposure period. Rather, the injected nanoparticulates were found to be agglomerated in the vicinity of the knee joint, surrounded by macrophages. Importantly, the absence of any systemic toxicity response in any of the vital organs in the treated mouse model, other than a mild local response at the site of delivery, was recorded. The serum biochemical analyses using proinflammatory cytokines (TNF-α and IL-1β) also complimented to the non-immunogenic response to injected particulates. Altogether, the absence of any inflammatory/adverse reaction will open up myriad of opportunities for BaTiO3 based piezoelectric implantable devices in biomedical applications.
Collapse
Affiliation(s)
- Ashutosh Kumar Dubey
- Laboratory for Biomaterials, Materials Research Centre, Indian Institute of Science, Bangalore, 560012, India
| | | | | |
Collapse
|
50
|
Chen K, Zhang D, Cui X, Wang Q. Preparation of ultrahigh-molecular-weight polyethylene grafted with polyvinyl alcohol hydrogel as an artificial joint. RSC Adv 2015. [DOI: 10.1039/c5ra00307e] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
A chemical grafting method was used to graft UHMWPE with PVA hydrogel to be used as an artificial joint.
Collapse
Affiliation(s)
- Kai Chen
- School of Mechanical and Electrical Engineering
- China University of Mining and Technology
- Xuzhou 221116
- China
| | - Dekun Zhang
- School of Materials Science and Engineering
- China University of Mining and Technology
- Xuzhou 221116
- China
| | - Xiaotong Cui
- School of Materials Science and Engineering
- China University of Mining and Technology
- Xuzhou 221116
- China
| | - Qingliang Wang
- School of Materials Science and Engineering
- China University of Mining and Technology
- Xuzhou 221116
- China
| |
Collapse
|