Draeger E, Roberts K, Decker RD, Bahar N, Wilson LD, Contessa J, Husain Z, Williams BB, Flood AB, Swartz HM, Carlson DJ. In Vivo Verification of Electron Paramagnetic Resonance Biodosimetry Using Patients Undergoing Radiation Therapy Treatment. Int J Radiat Oncol Biol Phys 2024; 119:292-301. [PMID: 38072322 DOI: 10.1016/j.ijrobp.2023.11.029] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2023] [Revised: 09/28/2023] [Accepted: 11/19/2023] [Indexed: 01/06/2024]
Abstract
PURPOSE Electron paramagnetic resonance (EPR) biodosimetry, used to triage large numbers of individuals incidentally exposed to unknown doses of ionizing radiation, is based on detecting a stable physical response in the body that is subject to quantifiable variation after exposure. In vivo measurement is essential to fully characterize the radiation response relevant to a living tooth measured in situ. The purpose of this study was to verify EPR spectroscopy in vivo by estimating the radiation dose received in participants' teeth. METHODS AND MATERIALS A continuous wave L-band spectrometer was used for EPR measurements. Participants included healthy volunteers and patients undergoing head and neck and total body irradiation treatments. Healthy volunteers completed 1 measurement each, and patients underwent measurement before starting treatment and between subsequent fractions. Optically stimulated luminescent dosimeters and diodes were used to determine the dose delivered to the teeth to validate EPR measurements. RESULTS Seventy measurements were acquired from 4 total body irradiation and 6 head and neck patients over 15 months. Patient data showed a linear increase of EPR signal with delivered dose across the dose range tested. A linear least-squares weighted fit of the data gave a statistically significant correlation between EPR signal and absorbed dose (P < .0001). The standard error of inverse prediction (SEIP), used to assess the usefulness of fits, was 1.92 Gy for the dose range most relevant for immediate triage (≤7 Gy). Correcting for natural background radiation based on patient age reduced the SEIP to 1.51 Gy. CONCLUSIONS This study demonstrated the feasibility of using spectroscopic measurements from radiation therapy patients to validate in vivo EPR biodosimetry. The data illustrated a statistically significant correlation between the magnitude of EPR signals and absorbed dose. The SEIP of 1.51 Gy, obtained under clinical conditions, indicates the potential value of this technique in response to large radiation events.
Collapse
Affiliation(s)
- Emily Draeger
- Department of Therapeutic Radiology, Yale University School of Medicine, New Haven, Connecticut.
| | - Kenneth Roberts
- Department of Therapeutic Radiology, Yale University School of Medicine, New Haven, Connecticut
| | - Roy D Decker
- Department of Therapeutic Radiology, Yale University School of Medicine, New Haven, Connecticut
| | - Nina Bahar
- Department of Therapeutic Radiology, Yale University School of Medicine, New Haven, Connecticut
| | - Lynn D Wilson
- Department of Therapeutic Radiology, Yale University School of Medicine, New Haven, Connecticut
| | - Joseph Contessa
- Department of Therapeutic Radiology, Yale University School of Medicine, New Haven, Connecticut
| | - Zain Husain
- Department of Therapeutic Radiology, Yale University School of Medicine, New Haven, Connecticut
| | - Benjamin B Williams
- Department of Radiology & EPR Center, Geisel Medical School at Dartmouth, Hanover, New Hampshire
| | - Ann Barry Flood
- Department of Radiology & EPR Center, Geisel Medical School at Dartmouth, Hanover, New Hampshire
| | - Harold M Swartz
- Department of Radiology & EPR Center, Geisel Medical School at Dartmouth, Hanover, New Hampshire
| | - David J Carlson
- Department of Therapeutic Radiology, Yale University School of Medicine, New Haven, Connecticut.
| |
Collapse
|
2
|
Park JI, Koo CU, Oh J, Kim IJ, Choi K, Ye SJ. Enhancing Precision in L-band Electron Paramagnetic Resonance Tooth Dosimetry: Incorporating Digital Image Processing and Radiation Therapy Plans for Geometric Correction. HEALTH PHYSICS 2024; 126:79-95. [PMID: 37948057 DOI: 10.1097/hp.0000000000001773] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/12/2023]
Abstract
ABSTRACT Following unforeseen exposure to radiation, quick dose determination is essential to prioritize potential patients that require immediate medical care. L-band electron paramagnetic resonance tooth dosimetry can be efficiently used for rapid triage as this poses no harm to the human incisor, although geometric variations among human teeth may hinder accurate dose estimation. Consequently, we propose a practical geometric correction method using a mobile phone camera. Donated human incisors were irradiated with calibrated 6-MV photon beam irradiation, and dose-response curves were developed by irradiation with a predetermined dose using custom-made poly(methyl methacrylate) slab phantoms. Three radiation treatment plans for incisors were selected and altered to suit the head phantom. The mean doses on tooth structures were calculated using a commercial treatment planning system, and the electron paramagnetic resonance signals of the incisors were measured. The enamel area was computed from camera-acquired tooth images. The relative standard uncertainty was rigorously estimated both with and without geometric correction. The effects on the electron paramagnetic resonance signal caused by axial and rotational movements of tooth samples were evaluated through finite element analysis. The mean absolute deviations of mean doses both with and without geometric correction showed marginal improvement. The average relative differences without and with geometric correction significantly decreased from 21.0% to 16.8% (p = 0.01). The geometric correction method shows potential in improving dose precision measurement with minimal delay. Furthermore, our findings demonstrated the viability of using treatment planning system doses in dose estimation for L-band electron paramagnetic resonance tooth dosimetry.
Collapse
Affiliation(s)
- Jong In Park
- Korea Research Institute of Standards and Science, 267 Gajeong-ro, Yuseong-gu, Daejeon 34113, Republic of Korea
| | - Chang Uk Koo
- Program in Biomedical Radiation Sciences, Department of Transdisciplinary Studies, Graduate School of Convergence Science and Technology, Seoul National University, Seoul, 08826, Republic of Korea
| | - Jeonghun Oh
- Program in Biomedical Radiation Sciences, Department of Transdisciplinary Studies, Graduate School of Convergence Science and Technology, Seoul National University, Seoul, 08826, Republic of Korea
| | - In Jung Kim
- Korea Research Institute of Standards and Science, 267 Gajeong-ro, Yuseong-gu, Daejeon 34113, Republic of Korea
| | - Kwon Choi
- Program in Biomedical Radiation Sciences, Department of Transdisciplinary Studies, Graduate School of Convergence Science and Technology, Seoul National University, Seoul, 08826, Republic of Korea
| | | |
Collapse
|
3
|
Ghimire L, Waller E. Methodology and Instrumentation for Electron Paramagnetic Resonance Dosimetry With Tooth Enamel. JOURNAL OF NUCLEAR ENGINEERING AND RADIATION SCIENCE 2023. [DOI: 10.1115/1.4055162] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Abstract
When tooth enamel is exposed to ionizing radiation, it generates a dose-dependent concentration of free radical centers (i.e., unpaired electrons). The concentration of these free radical centers is identified and quantified using electron paramagnetic resonance (EPR) spectroscopy in the form of an EPR spectrum. The intensity of the spectrum is proportional to the absorbed dose. Four international intercomparisons have already demonstrated that the EPR tooth enamel dosimetric technique is reliable for retrospective dose assessment in acute and chronic exposure scenarios. Additionally, EPR dosimetry is regarded same as a gold standard for reconstructing the total lifetime dose of individuals using tooth enamel. The accuracy and reproducibility of EPR dose reconstruction depend on the sample preparation, spectrum acquisition, and EPR spectra analysis techniques. So, this paper reviews some of the widely applied and accepted laboratory protocols or methodologies for the EPR dosimetric methods. The minimum detection limit in tooth enamel using this technique was 30 mGy. So, this review aims to share these protocols so that it would be easy to reconstruct the accident doses or chronic exposures with reliable accuracy and precision. Different bands (e.g., L, X, Q, etc.) continuous wave (CW) EPR spectrometers have been used in many historical and accident dose reconstructions; however, due to the availability, moderate price, and not being much influenced by the small amount of moisture in a sample, the X-band has been widely used. A well-developed methodology, a highly sensitive EPR spectrometer, and a well-trained operator are vital for the reliable measurements of absorbed low doses in EPR dosimetry with tooth enamel.
Collapse
Affiliation(s)
- Lekhnath Ghimire
- Faculty of Energy Systems and Nuclear Science, Ontario Tech University , Oshawa, ON L1G 0C5, Canada
| | - Edward Waller
- Faculty of Energy Systems and Nuclear Science, Ontario Tech University , Oshawa, ON L1G 0C5, Canada
| |
Collapse
|
4
|
Kmiec MM, Hebert KA, Tse D, Hodge S, Williams BB, Schaner PE, Kuppusamy P. OxyChip embedded with radio-opaque gold nanoparticles for anatomic registration and oximetry in tissues. Magn Reson Med 2022; 87:1621-1637. [PMID: 34719047 PMCID: PMC8776570 DOI: 10.1002/mrm.29039] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2021] [Revised: 09/07/2021] [Accepted: 09/18/2021] [Indexed: 11/07/2022]
Abstract
PURPOSE Electron paramagnetic resonance oximetry using the OxyChip as an implantable oxygen sensor can directly and repeatedly measure tissue oxygen levels. A phase I, first-in-human clinical study has established the safety and feasibility of using OxyChip for reliable and repeated measurements of oxygen levels in a variety of tumors and treatment regimens. A limitation in these studies is the inability to easily locate and identify the implanted probes in the tissue, particularly in the long term, thus limiting spatial/anatomical registration of the implant for proper interpretation of the oxygen data. In this study, we have developed and evaluated an enhanced oxygen-sensing probe embedded with gold nanoparticles (GNP), called the OxyChip-GNP, to enable visualization of the sensor using routine clinical imaging modalities. METHODS In vitro characterization, imaging, and histopathology studies were carried out using tissue phantoms, excised tissues, and in vivo animal models (mice and rats). RESULTS The results demonstrated a substantial enhancement of ultrasound and CT contrast using the OxyChip-GNP without compromising its electron paramagnetic resonance and oxygen-sensing properties or biocompatibility. CONCLUSIONS The OxyChips embedded with gold nanoparticles (OxyChip-GNP) can be readily identified in soft tissues using standard clinical imaging modalities such as CT, cone beam-CT, or ultrasound imaging while maintaining its capability to make repeated in vivo measurements of tissue oxygen levels over the long term. This unique capability of the OxyChip-GNP facilitates precisely localized in vivo oxygen measurements in the clinical setting.
Collapse
Affiliation(s)
- Maciej M. Kmiec
- Department of Radiology, Norris Cotton Cancer Center, Geisel School of Medicine Dartmouth College Lebanon New Hampshire USA
| | - Kendra A. Hebert
- Department of Radiology, Norris Cotton Cancer Center, Geisel School of Medicine Dartmouth College Lebanon New Hampshire USA
| | - Dan Tse
- Department of Radiology, Norris Cotton Cancer Center, Geisel School of Medicine Dartmouth College Lebanon New Hampshire USA
| | - Sassan Hodge
- Thayer School of Engineering Dartmouth College Hanover New Hampshire USA
| | - Benjamin B. Williams
- Department of Radiology, Norris Cotton Cancer Center, Geisel School of Medicine Dartmouth College Lebanon New Hampshire USA
- Thayer School of Engineering Dartmouth College Hanover New Hampshire USA
- Department of Medicine Dartmouth‐Hitchcock Medical Center Lebanon New Hampshire USA
| | - Philip E. Schaner
- Department of Medicine Dartmouth‐Hitchcock Medical Center Lebanon New Hampshire USA
| | - Periannan Kuppusamy
- Department of Radiology, Norris Cotton Cancer Center, Geisel School of Medicine Dartmouth College Lebanon New Hampshire USA
- Thayer School of Engineering Dartmouth College Hanover New Hampshire USA
- Department of Medicine Dartmouth‐Hitchcock Medical Center Lebanon New Hampshire USA
| |
Collapse
|
5
|
X-band TE101 rectangular aperture cavity for in vivo EPR tooth dosimetry after radiation emergency. Appl Radiat Isot 2021; 178:109958. [PMID: 34598040 DOI: 10.1016/j.apradiso.2021.109958] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2020] [Revised: 08/25/2021] [Accepted: 09/16/2021] [Indexed: 11/22/2022]
Abstract
The TE101 mode rectangle EPR cavity was newly developed to achieve X-band in vivo EPR tooth dosimetry for the rescue of nuclear emergency. An aperture for sample detection was opened on the cavity's surface. Its characteristics were evaluated by measuring DPPH and intact human incisor samples. Remarkable radiation induced signal from EPR spectrum of 1Gy-8Gy irradiated teeth was observed. In vivo measurements of rat was performed to verify its application for in vivo tooth dosimetry.
Collapse
|
6
|
Weaver J, Liu KJ. A Review of Low-Frequency EPR Technology for the Measurement of Brain pO2 and Oxidative Stress. APPLIED MAGNETIC RESONANCE 2021; 52:1379-1394. [PMID: 35340811 PMCID: PMC8945541 DOI: 10.1007/s00723-021-01384-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/10/2021] [Revised: 06/24/2021] [Accepted: 06/30/2021] [Indexed: 06/14/2023]
Abstract
EPR can uniquely measure paramagnetic species. Although commercial EPR was introduced in 1950s, the early studies were mostly restricted to chemicals in solution or cellular experiments using X-band EPR equipment. Due to its limited penetration (<1 mm), experiments with living animals were almost impossible. To overcome these difficulties, Swartz group, along with several other leaders in field, pioneered the technology of low frequency EPR (e.g., L-band, 1-2 GHz). The development of low frequency EPR and the associated probes have dramatically expanded the application of EPR technology into the biomedical research field, providing answers to important scientific questions by measuring specific parameters that are impossible or very difficult to obtain by other approaches. In this review, which is aimed at highlighting the seminal contribution from Swartz group over the last several decades, we will focus on the development of EPR technology that was designed to deal with the potential challenges arising from conducting EPR spectroscopy in living animals. The second half of the review will be concentrated on the application of low frequency EPR in measuring cerebral tissue pO2 changes and oxidative stress in various physiological and pathophysiological conditions in the brain of animal disease models.
Collapse
Affiliation(s)
- John Weaver
- Department of Pharmaceutical Sciences, College of Pharmacy, University of New Mexico Health Sciences Center, Albuquerque, NM 87131
| | - Ke Jian Liu
- Department of Pharmaceutical Sciences, College of Pharmacy, University of New Mexico Health Sciences Center, Albuquerque, NM 87131
| |
Collapse
|
7
|
Samouilov A, Komarov D, Petryakov S, Iosilevich A, Zweier JL. Development of an L-band resonator optimized for fast scan EPR imaging of the mouse head. Magn Reson Med 2021; 86:2316-2327. [PMID: 33938574 PMCID: PMC8295191 DOI: 10.1002/mrm.28821] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2020] [Revised: 04/07/2021] [Accepted: 04/08/2021] [Indexed: 12/11/2022]
Abstract
PURPOSE To develop a novel resonator for high-quality fast scan electron paramagnetic resonance (EPR) and EPR/NMR co-imaging of the head and brain of mice at 1.25 GHz. METHODS Resonator dimensions were scaled to fit the mouse head with maximum filling factor. A single-loop 6-gap resonator of 20 mm diameter and 20 mm length was constructed. High resonator stability was achieved utilizing a fixed position double coupling loop. Symmetrical mutually inverted connections rendered it insensitive to field modulation and fast scan. Coupling adjustment was provided by a parallel-connected variable capacitor located at the feeding line at λ/4 distance. To minimize radiation loss, the shield around the resonator was supplemented with a planar conductive disc that focuses return magnetic flux. RESULTS Coupling of the resonator loaded with the mouse head was efficient and easy. This resonator enabled high-quality in vivo 3D EPR imaging of the mouse head following intravenous infusion of nitroxide probes. With this resonator and rapid scan EPR system, 4 ms scans were acquired in forward and reverse directions so that images with 2-scan 3,136 projections were acquired in 25 s. Head images were achieved with resolutions of 0.4 mm, enabling visualization of probe localization and uptake across the blood-brain barrier. CONCLUSIONS This resonator design provides good sensitivity, high stability, and B1 field homogeneity for in vivo fast scan EPR of the mouse head and brain, enabling faster measurements and higher resolution imaging of probe uptake, localization, and metabolism than previously possible.
Collapse
Affiliation(s)
- Alexandre Samouilov
- Davis Heart and Lung Research Institute, and the Division of Cardiovascular Medicine, Department of Internal Medicine, The Ohio State University College of Medicine, Columbus, OH 43210 USA
| | - Denis Komarov
- Davis Heart and Lung Research Institute, and the Division of Cardiovascular Medicine, Department of Internal Medicine, The Ohio State University College of Medicine, Columbus, OH 43210 USA
| | - Sergey Petryakov
- Davis Heart and Lung Research Institute, and the Division of Cardiovascular Medicine, Department of Internal Medicine, The Ohio State University College of Medicine, Columbus, OH 43210 USA
| | - Arkadiy Iosilevich
- Davis Heart and Lung Research Institute, and the Division of Cardiovascular Medicine, Department of Internal Medicine, The Ohio State University College of Medicine, Columbus, OH 43210 USA
| | - Jay L. Zweier
- Davis Heart and Lung Research Institute, and the Division of Cardiovascular Medicine, Department of Internal Medicine, The Ohio State University College of Medicine, Columbus, OH 43210 USA
| |
Collapse
|
8
|
The design of X-band EPR cavity with narrow detection aperture for in vivo fingernail dosimetry after accidental exposure to ionizing radiation. Sci Rep 2021; 11:2883. [PMID: 33558592 PMCID: PMC7870891 DOI: 10.1038/s41598-021-82462-3] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2020] [Accepted: 01/20/2021] [Indexed: 11/13/2022] Open
Abstract
For the purpose of assessing the radiation dose of the victims involved in the nuclear emergency or radiation accident, a new type of X-band EPR resonant cavity for in vivo fingernail EPR dosimetry was designed and a homemade EPR spectrometer for in vivo fingernail detection was constructed. The microwave resonant mode of the cavity was rectangular TE101, and there was a narrow aperture for fingernail detection opened on the cavity’s wall at the position of high detection sensitivity. The DPPH dot sample and the fingernail samples were measured based on the in vivo fingernail EPR spectrometer. The measurements of the DPPH dot sample verified the preliminary functional applicable of the EPR spectrometer and illustrated the microwave power and modulation response features. The fingernails after irradiation by gamma-ray were measured and the radiation-induced signal was acquired. The results indicated that the cavity and the in vivo EPR dosimeter instrument was able to detect the radiation-induced signal in irradiated fingernail, and preliminarily verified the basic function of the instrument and its potential for emergency dose estimate after a radiation accident.
Collapse
|
9
|
Park JI, Choi K, Koo CU, Oh J, Hirata H, Swartz HM, Ye SJ. Dependence of Radiation-induced Signals on Geometry of Tooth Enamel Using a 1.15 GHz Electron Paramagnetic Resonance Spectrometer: Improvement of Dosimetric Accuracy. HEALTH PHYSICS 2021; 120:152-162. [PMID: 32701613 DOI: 10.1097/hp.0000000000001292] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
ABSTRACT We aim to improve the accuracy of electron paramagnetic resonance (EPR)-based in vivo tooth dosimetry using the relationship between tooth geometry and radiation-induced signals (RIS). A homebuilt EPR spectrometer at L-band frequency of 1.15 GHz originally designed for non-invasive and in vivo measurements of intact teeth was used to measure the RIS of extracted human teeth. Twenty human central incisors were scanned by microCT and irradiated by 220 kVp x-rays. The RISs of the samples were measured by the EPR spectrometer as well as simulated by using the finite element analysis of the electromagnetic field. A linear relationship between simulated RISs and tooth geometric dimensions, such as enamel area, enamel volume, and labial enamel volume, was confirmed. The dose sensitivity was quantified as a slope of the calibration curve (i.e., RIS vs. dose) for each tooth sample. The linear regression of these dose sensitivities was established for each of three tooth geometric dimensions. Based on these findings, a method for the geometry correction was developed by use of expected dose sensitivity of a certain tooth for one of the tooth geometric dimensions. Using upper incisors, the mean absolute deviation (MAD) without correction was 1.48 Gy from an estimated dose of 10 Gy; however, the MAD corrected by enamel area, volume, and labial volume was reduced to 1.04 Gy, 0.77 Gy, and 0.83 Gy, respectively. In general, the method corrected by enamel volume showed the best accuracy in this study. This homebuilt EPR spectrometer for the purpose of non-invasive and in vivo tooth dosimetry was successfully tested for achieving measurements in situ. We demonstrated that the developed correction method could reduce dosimetric uncertainties resulting from the variations in tooth geometric dimensions.
Collapse
Affiliation(s)
| | | | | | - Jeonghun Oh
- Program in Biomedical Radiation Sciences, Department of Transdisciplinary Studies, Graduate School of Convergence Science and Technology, Seoul National University, Seoul, 08826, Republic of Korea
| | - Hiroshi Hirata
- Division of Bioengineering and Bioinformatics, Graduate School of Information Science and Technology, Hokkaido University, Sapporo, 060-0814, Japan
| | - Harold M Swartz
- Geisel School of Medicine, HB 7785 Dartmouth College, Hanover, NH 03755
| | | |
Collapse
|
10
|
Implantable microchip containing oxygen-sensing paramagnetic crystals for long-term, repeated, and multisite in vivo oximetry. Biomed Microdevices 2019; 21:71. [PMID: 31286244 DOI: 10.1007/s10544-019-0421-x] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
EPR oximetry is established as a viable method for measuring the tissue oxygen level (partial pressure of oxygen, pO2) in animal models; however, it has not yet been established for measurements in humans. EPR oximetry requires an oxygen-sensing paramagnetic probe (molecular or particulate) to be placed at the site/organ of measurement, which may pose logistical and safety concerns, including invasiveness of the probe-placement procedure as well as lack of temporal stability and sensitivity for long-term (repeated) measurements, and possible toxicity in the short- and long-term. In the past, we have developed an implantable oxygen-sensing probe, called OxyChip, which we have successfully established for oximetry in pre-clinical animal models (Hou et al. Biomed. Microdevices 20, 29, 2018). Currently, OxyChip is being evaluated in a limited clinical trial in cancer patients. A major limitation of OxyChip is that it is a large (1.4 mm3) implant and hence not suitable for measuring oxygen heterogeneity that may be present in solid tumors, chronic wounds, etc. In this report, we describe the development of a substantially smaller version of OxyChip (0.07 mm3 or 70 cubic micron), called mChip, that can be placed in the tissue of interest using a 23G syringe-needle with minimal invasiveness. Using in vitro and in vivo models, we have shown that the microchip provides adequate EPR sensitivity, stability, and biocompatibility and thus enables robust, repeated, and simultaneous measurement from multiple implants providing mean and median pO2 values in the implanted region. The mChips will be particularly useful for those applications that require repeated measurements of mean/median pO2 in superficial tissues and malignancies.
Collapse
|
11
|
Kmiec MM, Hou H, Lakshmi Kuppusamy M, Drews TM, Prabhat AM, Petryakov SV, Demidenko E, Schaner PE, Buckey JC, Blank A, Kuppusamy P. Transcutaneous oxygen measurement in humans using a paramagnetic skin adhesive film. Magn Reson Med 2018; 81:781-794. [PMID: 30277275 DOI: 10.1002/mrm.27445] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2018] [Revised: 06/11/2018] [Accepted: 06/11/2018] [Indexed: 01/20/2023]
Abstract
PURPOSE Transcutaneous oxygen tension (TcpO2 ) provides information about blood perfusion in the tissue immediately below the skin. These data are valuable in assessing wound healing problems, diagnosing peripheral vascular/arterial insufficiency, and predicting disease progression or the response to therapy. Currently, TcpO2 is primarily measured using electrochemical skin sensors, which consume oxygen and are prone to calibration errors. The goal of the present study was to develop a reliable method for TcpO2 measurement in human subjects. METHODS We have developed a novel TcpO2 oximetry method based on electron paramagnetic resonance (EPR) principles with an oxygen-sensing skin adhesive film, named the superficial perfusion oxygen tension (SPOT) chip. The SPOT chip is a 3-mm diameter, 60-μm thick circular film composed of a stable paramagnetic oxygen sensor. The chip is covered with an oxygen-barrier material on one side and secured on the skin by a medical adhesive transfer tape to ensure that only the oxygen that diffuses through the skin surface is measured. The method quantifies TcpO2 through the linewidth of the EPR spectrum. RESULTS Repeated measurements using a cohort of 10 healthy human subjects showed that the TcpO2 measurements were robust, reliable, and reproducible. The TcpO2 values ranged from 7.8 ± 0.8 to 22.0 ± 1.0 mmHg in the volar forearm skin (N = 29) and 8.1 ± 0.3 to 23.4 ± 1.3 mmHg in the foot (N = 86). CONCLUSIONS The results demonstrated that the SPOT chip can measure TcpO2 reliably and repeatedly under ambient conditions. The SPOT chip method could potentially be used to monitor TcpO2 in the clinic.
Collapse
Affiliation(s)
- Maciej M Kmiec
- Department of Radiology, Geisel School of Medicine, Dartmouth College, Lebanon, New Hampshire
| | - Huagang Hou
- Department of Radiology, Geisel School of Medicine, Dartmouth College, Lebanon, New Hampshire
| | - M Lakshmi Kuppusamy
- Department of Radiology, Geisel School of Medicine, Dartmouth College, Lebanon, New Hampshire
| | - Thomas M Drews
- Department of Chemistry, University of Massachusetts, Amherst, Massachusetts
| | - Anjali M Prabhat
- Department of Radiology, Geisel School of Medicine, Dartmouth College, Lebanon, New Hampshire
| | - Sergey V Petryakov
- Department of Radiology, Geisel School of Medicine, Dartmouth College, Lebanon, New Hampshire
| | - Eugene Demidenko
- Department of Biomedical Data Sciences, Geisel School of Medicine, Dartmouth College, Lebanon, New Hampshire
| | - Philip E Schaner
- Department of Medicine, Geisel School of Medicine, Dartmouth College, Lebanon, New Hampshire
| | - Jay C Buckey
- Department of Medicine, Geisel School of Medicine, Dartmouth College, Lebanon, New Hampshire
| | - Aharon Blank
- Schulich Faculty of Chemistry Technion, Israel Institute of Technology, Haifa, Israel
| | - Periannan Kuppusamy
- Department of Radiology, Geisel School of Medicine, Dartmouth College, Lebanon, New Hampshire.,Department of Chemistry, University of Massachusetts, Amherst, Massachusetts
| |
Collapse
|
12
|
Kobayashi K, Dong R, Nicolalde RJ, Calderon P, Du G, Williams BB, Lee MCI, Swartz HM, Flood AB. Development of a novel mouth model as an alternative tool to test the effectiveness of an in vivo EPR dosimetry system. Phys Med Biol 2018; 63:165002. [PMID: 30033935 DOI: 10.1088/1361-6560/aad518] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
In a large-scale radiation event, thousands may be exposed to unknown amounts of radiation, some of which may be life-threatening without immediate attention. In such situations, a method to quickly and reliably estimate dose would help medical responders triage victims to receive life-saving care. We developed such a method using electron paramagnetic resonance (EPR) to make in vivo measurements of the maxillary incisors. This report provides evidence that the use of in vitro studies can provide data that are fully representative of the measurements made in vivo. This is necessary because, in order to systematically test and improve the reliability and accuracy of the dose estimates made with our EPR dosimetry system, it is important to conduct controlled studies in vitro using irradiated human teeth. Therefore, it is imperative to validate whether our in vitro models adequately simulate the measurements made in vivo, which are intended to help guide decisions on triage after a radiation event. Using a healthy volunteer with a dentition gap that allows using a partial denture, human teeth were serially irradiated in vitro and then, using a partial denture, placed in the volunteer's mouth for measurements. We compared dose estimates made using in vivo measurements made in the volunteer's mouth to measurements made on the same teeth in our complex mouth model that simulates electromagnetic and anatomic properties of the mouth. Our results demonstrate that this mouth model can be used in in vitro studies to develop the system because these measurements appropriately model in vivo conditions.
Collapse
Affiliation(s)
- Kyo Kobayashi
- EPR Center for the Study of Viable Systems, Radiology Department, Geisel School of Medicine at Dartmouth, HB 7785, Williamson Translational Research Bldg, Lebanon, NH, United States of America
| | | | | | | | | | | | | | | | | |
Collapse
|
13
|
Nakagawa K, Minakawa S, Sawamura D. Melanin Radicals in Paraffin-embedded Melanoma Investigated Using Surface-type Dielectric Resonator for X-band EPR. ANAL SCI 2018; 34:837-840. [PMID: 29998967 DOI: 10.2116/analsci.18p055] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
We investigated melanin radicals in paraffin-embedded malignant melanoma (MM) using a surface-type dielectric resonator for X-band electron paramagnetic resonance (EPR) and analyzed the radical species. The surface-type resonator's performance was examined using 5 - 10 μL of 0.1 mM 4-hydroxy-2,2,6,6-tetramethylpiperidine-1-oxyl (TEMPOL) aqueous solution in a 1.0-mm (i.d.) glass capillary as well as 1,1-diphenyl-2-picrylhydrazyl (DPPH) powder. The surface-type detection has approximately two times poorer S/N ratio than commercial insertion-type detection. A sample of the paraffin-embedded MM specimen was used for the radical detection. We obtained an EPR spectrum of melanin radicals in the paraffin-embedded melanoma sample (size ∼3 × 4 × 3 mm). A single line (∼0.64 mT peak-to-peak line-width) with a small shoulder was observed and was identified as a pheomelanin-related radical. The pheomelanin radical can be directly related to the MM. Thus, the present results were a good indication for noninvasive measurement, as well as for detailed analyses of melanin radicals in human MM.
Collapse
Affiliation(s)
- Kouichi Nakagawa
- Division of Regional Innovation, Graduate School of Health Sciences, Hirosaki University
| | - Satoko Minakawa
- Department of Dermatology, Graduate School of Medicine, Hirosaki University
| | - Daisuke Sawamura
- Department of Dermatology, Graduate School of Medicine, Hirosaki University
| |
Collapse
|
14
|
Caston RM, Schreiber W, Hou H, Williams BB, Chen EY, Schaner PE, Jarvis LA, Flood AB, Petryakov SV, Kmiec MM, Kuppusamy P, Swartz HM. Development of the Implantable Resonator System for Clinical EPR Oximetry. Cell Biochem Biophys 2017; 75:275-283. [PMID: 28687906 DOI: 10.1007/s12013-017-0809-2] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2017] [Accepted: 06/06/2017] [Indexed: 11/24/2022]
Abstract
Hypoxic tumors are more resistant to radiotherapy and chemotherapy, which decreases the efficacy of these common forms of treatment. We have been developing implantable paramagnetic particulates to measure oxygen in vivo using electron paramagnetic resonance. Once implanted, oxygen can be measured repeatedly and non-invasively in superficial tissues (<3 cm deep), using an electron paramagnetic resonance spectrometer and an external surface-loop resonator. To significantly extend the clinical applications of electron paramagnetic resonance oximetry, we developed an implantable resonator system to obtain measurements at deeper sites. This system has been used to successfully obtain oxygen measurements in animal studies for several years. We report here on recent developments needed to meet the regulatory requirements to make this technology available for clinical use. radio frequency heating is discussed and magnetic resonance compatibility testing of the device has been carried out by a Good Laboratory Practice-certified laboratory. The geometry of the implantable resonator has been modified to meet our focused goal of verifying safety and efficacy for the proposed use of intracranial measurements and also for future use in tissue sites other than the brain. We have encapsulated the device within a smooth cylindrical-shaped silicone elastomer to prevent tissues from adhering to the device and to limit perturbation of tissue during implantation and removal. We have modified the configuration for simultaneously measuring oxygen at multiple sites by developing a linear array of oxygen sensing probes, which each provide independent measurements. If positive results are obtained in additional studies which evaluate biocompatibility and chemical characterization, we believe the implantable resonator will be at a suitable stage for initial testing in human subjects.
Collapse
Affiliation(s)
- Rose M Caston
- EPR Center for the Study of Viable Systems at Dartmouth College, Hanover, USA.
| | - Wilson Schreiber
- EPR Center for the Study of Viable Systems at Dartmouth College, Hanover, USA
| | - Huagang Hou
- EPR Center for the Study of Viable Systems at Dartmouth College, Hanover, USA
| | - Benjamin B Williams
- EPR Center for the Study of Viable Systems at Dartmouth College, Hanover, USA
| | - Eunice Y Chen
- EPR Center for the Study of Viable Systems at Dartmouth College, Hanover, USA
| | - Philip E Schaner
- EPR Center for the Study of Viable Systems at Dartmouth College, Hanover, USA
| | - Lesley A Jarvis
- EPR Center for the Study of Viable Systems at Dartmouth College, Hanover, USA
| | - Ann Barry Flood
- EPR Center for the Study of Viable Systems at Dartmouth College, Hanover, USA
| | - Sergey V Petryakov
- EPR Center for the Study of Viable Systems at Dartmouth College, Hanover, USA
| | - Maciej M Kmiec
- EPR Center for the Study of Viable Systems at Dartmouth College, Hanover, USA
| | - Periannan Kuppusamy
- EPR Center for the Study of Viable Systems at Dartmouth College, Hanover, USA
| | - Harold M Swartz
- EPR Center for the Study of Viable Systems at Dartmouth College, Hanover, USA
| |
Collapse
|
15
|
Hou H, Khan N, Gohain S, Eskey CJ, Moodie KL, Maurer KJ, Swartz HM, Kuppusamy P. Dynamic EPR Oximetry of Changes in Intracerebral Oxygen Tension During Induced Thromboembolism. Cell Biochem Biophys 2017; 75:285-294. [PMID: 28434138 DOI: 10.1007/s12013-017-0798-1] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2017] [Accepted: 04/12/2017] [Indexed: 12/19/2022]
Abstract
Cerebral tissue oxygenation (oxygen tension, pO2) is a critical parameter that is closely linked to brain metabolism, function, and pathophysiology. In this work, we have used electron paramagnetic resonance oximetry with a deep-tissue multi-site oxygen-sensing probe, called implantable resonator, to monitor temporal changes in cerebral pO2 simultaneously at four sites in a rabbit model of ischemic stroke induced by embolic clot. The pO2 values in healthy brain were not significantly different among the four sites measured over a period of 4 weeks. During exposure to 15% O2 (hypoxia), a sudden and significant decrease in pO2 was observed in all four sites. On the other hand, brief exposure to breathing carbogen gas (95% O2 + 5% CO2) showed a significant increase in the cerebral pO2 from baseline value. During ischemic stroke, induced by embolic clot in the left brain, a significant decline in the pO2 of the left cortex (ischemic core) was observed without any change in the contralateral sites. While the pO2 in the non-infarct regions returned to baseline at 24-h post-stroke, pO2 in the infarct core was consistently lower compared to the baseline and other regions of the brain. The results demonstrated that electron paramagnetic resonance oximetry with the implantable resonator can repeatedly and simultaneously report temporal changes in cerebral pO2 at multiple sites. This oximetry approach can be used to develop interventions to rescue hypoxic/ischemic tissue by modulating cerebral pO2 during hypoxic and stroke injury.
Collapse
Affiliation(s)
- Huagang Hou
- Department of Radiology, The Geisel School of Medicine, Dartmouth College, 1 Medical Center Drive,, Lebanon, 03756, NH, USA
| | - Nadeem Khan
- Department of Radiology, The Geisel School of Medicine, Dartmouth College, 1 Medical Center Drive,, Lebanon, 03756, NH, USA
| | - Sangeeta Gohain
- Department of Radiology, The Geisel School of Medicine, Dartmouth College, 1 Medical Center Drive,, Lebanon, 03756, NH, USA
| | - Clifford J Eskey
- Department of Radiology, The Geisel School of Medicine, Dartmouth College, 1 Medical Center Drive,, Lebanon, 03756, NH, USA
| | - Karen L Moodie
- Center for Comparative Medicine and Research, Dartmouth College, 1 Medical Center Drive,, Lebanon, 03756, NH, USA
| | - Kirk J Maurer
- Center for Comparative Medicine and Research, Dartmouth College, 1 Medical Center Drive,, Lebanon, 03756, NH, USA
| | - Harold M Swartz
- Department of Radiology, The Geisel School of Medicine, Dartmouth College, 1 Medical Center Drive,, Lebanon, 03756, NH, USA
| | - Periannan Kuppusamy
- Department of Radiology, The Geisel School of Medicine, Dartmouth College, 1 Medical Center Drive,, Lebanon, 03756, NH, USA.
| |
Collapse
|
16
|
Miyake M, Nakai Y, Yamaguchi I, Hirata H, Kunugita N, Williams BB, Swartz HM. IN-VIVO RADIATION DOSIMETRY USING PORTABLE L BAND EPR: ON-SITE MEASUREMENT OF VOLUNTEERS IN FUKUSHIMA PREFECTURE, JAPAN. RADIATION PROTECTION DOSIMETRY 2016; 172:248-253. [PMID: 27522046 PMCID: PMC5225973 DOI: 10.1093/rpd/ncw214] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/13/2023]
Abstract
The aim of this study was to make direct measurements of the possible radiation-induced EPR signals in the teeth of volunteers who were residents in Fukushima within 80 km distance from the Fukushima Nuclear Power plant at the time of the disaster, and continued to live there for at least 3 month after the disaster. Thirty four volunteers were enrolled in this study. These measurements were made using a portable L-band EPR spectrometer, which was originally developed in the EPR Center at Dartmouth. All measurements were performed using surface loop resonators that have been specifically designed for the upper incisor teeth. Potentially these signals include not only radiation-induced signals induced by the incident but also background signals including those from prior radiation exposure from the environment and medical exposure. We demonstrated that it is feasible to transport the dosimeter to the measurement site and make valid measurements. The intensity of the signals that were obtained was not significantly above those seen in volunteers who had not had potential radiation exposures at Fukushima.
Collapse
Affiliation(s)
- Minoru Miyake
- Department of Oral and Maxillofacial Surgery, Faculty of Medicine, Kagawa University, 750-1 Ikenobe, Miki-cho, Kita-gun , Kagawa Prefecture 761-0793, Japan
| | - Yasuhiro Nakai
- Department of Oral and Maxillofacial Surgery, Faculty of Medicine, Kagawa University, 750-1 Ikenobe, Miki-cho, Kita-gun , Kagawa Prefecture 761-0793, Japan
| | - Ichiro Yamaguchi
- Department of Environmental Health, NIPH (National Institute of Public Health ), 2-3-6 Minami, Wako-shi , Saitama 351-0197, Japan
| | - Hiroshi Hirata
- EPR group in the Division of Bioengineering and Bioinformatics, Hokkaido University, Kita 14, Nishi 9, Kita-ku, Sapporo, Hokkaido 060-0814, Japan
| | - Naoki Kunugita
- Department of Environmental Health, NIPH (National Institute of Public Health ), 2-3-6 Minami, Wako-shi , Saitama 351-0197, Japan
| | - Benjamin B Williams
- Dartmouth EPR Center, Department of Radiology, The Geisel School of Medicine at Dartmouth, Lebanon, NH 03756, USA
| | - Harold M Swartz
- Dartmouth EPR Center, Department of Radiology, The Geisel School of Medicine at Dartmouth, Lebanon, NH 03756, USA
| |
Collapse
|
17
|
Schreiber W, Petryakov SV, Kmiec MM, Feldman MA, Meaney PM, Wood VA, Boyle HK, Flood AB, Williams BB, Swartz HM. FLEXIBLE, WIRELESS, INDUCTIVELY COUPLED SURFACE COIL RESONATOR FOR EPR TOOTH DOSIMETRY. RADIATION PROTECTION DOSIMETRY 2016; 172:87-95. [PMID: 27421470 PMCID: PMC6287419 DOI: 10.1093/rpd/ncw153] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
Managing radiation injuries following a catastrophic event where large numbers of people may have been exposed to life-threatening doses of ionizing radiation relies on the availability of biodosimetry to assess whether individuals need to be triaged for care. Electron Paramagnetic Resonance (EPR) tooth dosimetry is a viable method to accurately estimate the amount of ionizing radiation to which an individual has been exposed. In the intended measurement conditions and scenario, it is essential that the measurement process be fast, straightforward and provides meaningful and accurate dose estimations for individuals in the expected measurement conditions. The sensing component of a conventional L-band EPR spectrometer used for tooth dosimetry typically consists of a surface coil resonator that is rigidly, physically attached to the coupler. This design can result in cumbersome operation, limitations in teeth geometries that may be measured and hinder the overall utility of the dosimeter. A novel surface coil resonator has been developed for the currently existing L-band (1.15 GHz) EPR tooth dosimeter for the intended use as a point of care device by minimally trained operators. This resonator development provides further utility to the dosimeter, and increases the usability of the dosimeter by non-expert operators in the intended use scenario.
Collapse
Affiliation(s)
- Wilson Schreiber
- Department of Radiology, EPR Center for the Study of Viable Systems, Geisel School of Medicine at Dartmouth, Hanover, NH 03755, USA
| | - Sergey V Petryakov
- Department of Radiology, EPR Center for the Study of Viable Systems, Geisel School of Medicine at Dartmouth, Hanover, NH 03755, USA
| | - Maciej M Kmiec
- Department of Radiology, EPR Center for the Study of Viable Systems, Geisel School of Medicine at Dartmouth, Hanover, NH 03755, USA
| | - Matthew A Feldman
- Department of Radiology, EPR Center for the Study of Viable Systems, Geisel School of Medicine at Dartmouth, Hanover, NH 03755, USA
| | - Paul M Meaney
- Department of Radiology, EPR Center for the Study of Viable Systems, Geisel School of Medicine at Dartmouth, Hanover, NH 03755, USA
- Thayer School of Engineering at Dartmouth, Hanover, NH 03755, USA
| | - Victoria A Wood
- Department of Radiology, EPR Center for the Study of Viable Systems, Geisel School of Medicine at Dartmouth, Hanover, NH 03755, USA
| | - Holly K Boyle
- Department of Radiology, EPR Center for the Study of Viable Systems, Geisel School of Medicine at Dartmouth, Hanover, NH 03755, USA
| | - Ann Barry Flood
- Department of Radiology, EPR Center for the Study of Viable Systems, Geisel School of Medicine at Dartmouth, Hanover, NH 03755, USA
| | - Benjamin B Williams
- Department of Radiology, EPR Center for the Study of Viable Systems, Geisel School of Medicine at Dartmouth, Hanover, NH 03755, USA
| | - Harold M Swartz
- Department of Radiology, EPR Center for the Study of Viable Systems, Geisel School of Medicine at Dartmouth, Hanover, NH 03755, USA
| |
Collapse
|
18
|
Nakagawa K. Development of an innovative 9 GHz EPR surface detection method and its application to non-invasive human fingers and nails investigation. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2015; 150:461-464. [PMID: 26067935 DOI: 10.1016/j.saa.2015.05.065] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/22/2015] [Revised: 05/12/2015] [Accepted: 05/13/2015] [Indexed: 06/04/2023]
Abstract
We developed an innovative surface-type cavity for 9 GHz electron paramagnetic resonance (EPR) and used it to non-invasively measure human fingers and nails. This surface-type cavity measures a sample on the top of the cavity instead of a sample inserted into the cavity. To verify the performance of this method, 5-10 μL of 0.1 mM 4-hydroxy-2,2,6,6-tetramethylpiperidin-1-oxyl (TEMPOL) aqueous solution in a 1.0-mm (i.d.) glass capillary was used. Although the detectable radical concentration of the surface-type cavity is lower than that of a commercial cavity, the surface-type cavity can measure biomedical samples. In addition, the cavity is capable of measuring human fingers and nails. The dynamics of a topically applied 1.0-mM TEMPOL solution with a commercial lotion (5:1 by weight) on a human finger and nail were investigated. The present EPR results suggest that TEMPOL in solution may not easily permeate into the finger and nail during the measurements. Therefore, 9 GHz surface-type detection exhibits the good potential to study paramagnetic species in bulky biomedical samples.
Collapse
Affiliation(s)
- Kouichi Nakagawa
- Department of Radiological Life Sciences, Graduate School of Health Sciences, Hirosaki University, 66-1 Hon-cho, Hirosaki 036-8564, Japan.
| |
Collapse
|
19
|
Hou H, Krishnamurthy Nemani V, Du G, Montano R, Song R, Gimi B, Swartz HM, Eastman A, Khan N. Monitoring oxygen levels in orthotopic human glioma xenograft following carbogen inhalation and chemotherapy by implantable resonator-based oximetry. Int J Cancer 2014; 136:1688-96. [PMID: 25111969 DOI: 10.1002/ijc.29132] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2014] [Revised: 07/25/2014] [Accepted: 07/29/2014] [Indexed: 11/08/2022]
Abstract
Hypoxia is a critical hallmark of glioma, and significantly compromises treatment efficacy. Unfortunately, techniques for monitoring glioma pO2 to facilitate translational research are lacking. Furthermore, poor prognosis of patients with malignant glioma, in particular glioblastoma multiforme, warrant effective strategies that can inhibit hypoxia and improve treatment outcome. EPR oximetry using implantable resonators was implemented for monitoring pO2 in normal cerebral tissue and U251 glioma in mice. Breathing carbogen (95% O2 + 5% CO2 ) was tested for hyperoxia in the normal brain and glioma xenografts. A new strategy to inhibit glioma growth by rationally combining gemcitabine and MK-8776, a cell cycle checkpoint inhibitor, was also investigated. The mean pO2 of left and right hemisphere were ∼56-69 mmHg in the normal cerebral tissue of mice. The mean baseline pO2 of U251 glioma on the first and fifth day of measurement was 21.9 ± 3.7 and 14.1 ± 2.4 mmHg, respectively. The mean brain pO2 including glioma increased by at least 100% on carbogen inhalation, although the response varied between the animals over days. Treatment with gemcitabine + MK-8776 significantly increased pO2 and inhibited glioma growth assessed by MRI. In conclusion, EPR oximetry with implantable resonators can be used to monitor the efficacy of carbogen inhalation and chemotherapy on orthotopic glioma in mice. The increase in glioma pO2 of mice breathing carbogen can be used to improve treatment outcome. The treatment with gemcitabine + MK-8776 is a promising strategy that warrants further investigation.
Collapse
Affiliation(s)
- Huagang Hou
- EPR Center for the Study of Viable Systems, Department of Radiology, Geisel School of Medicine at Dartmouth, Hanover, NH; Norris Cotton Cancer Center, Dartmouth-Hitchcock Medical Center, Lebanon, NH
| | | | | | | | | | | | | | | | | |
Collapse
|
20
|
Williams BB, Flood AB, Salikhov I, Kobayashi K, Dong R, Rychert K, Du G, Schreiber W, Swartz HM. In vivo EPR tooth dosimetry for triage after a radiation event involving large populations. RADIATION AND ENVIRONMENTAL BIOPHYSICS 2014; 53:335-46. [PMID: 24711003 PMCID: PMC11064839 DOI: 10.1007/s00411-014-0534-9] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/19/2013] [Accepted: 02/27/2014] [Indexed: 05/26/2023]
Abstract
The management of radiation injuries following a catastrophic event where large numbers of people may have been exposed to life-threatening doses of ionizing radiation will rely critically on the availability and use of suitable biodosimetry methods. In vivo electron paramagnetic resonance (EPR) tooth dosimetry has a number of valuable and unique characteristics and capabilities that may help enable effective triage. We have produced a prototype of a deployable EPR tooth dosimeter and tested it in several in vitro and in vivo studies to characterize the performance and utility at the state of the art. This report focuses on recent advances in the technology, which strengthen the evidence that in vivo EPR tooth dosimetry can provide practical, accurate, and rapid measurements in the context of its intended use to help triage victims in the event of an improvised nuclear device. These advances provide evidence that the signal is stable, accurate to within 0.5 Gy, and can be successfully carried out in vivo. The stability over time of the radiation-induced EPR signal from whole teeth was measured to confirm its long-term stability and better characterize signal behavior in the hours following irradiation. Dosimetry measurements were taken for five pairs of natural human upper central incisors mounted within a simple anatomic mouth model that demonstrates the ability to achieve 0.5 Gy standard error of inverse dose prediction. An assessment of the use of intact upper incisors for dose estimation and screening was performed with volunteer subjects who have not been exposed to significant levels of ionizing radiation and patients who have undergone total body irradiation as part of bone marrow transplant procedures. Based on these and previous evaluations of the performance and use of the in vivo tooth dosimetry system, it is concluded that this system could be a very valuable resource to aid in the management of a massive radiological event.
Collapse
Affiliation(s)
- Benjamin B Williams
- Department of Radiology, EPR Center for the Study of Viable Systems, Geisel School of Medicine at Dartmouth, Hanover, NH, USA,
| | | | | | | | | | | | | | | | | |
Collapse
|
21
|
Hou H, Li H, Dong R, Khan N, Swartz H. Real-time monitoring of ischemic and contralateral brain pO2 during stroke by variable length multisite resonators. Magn Reson Imaging 2014; 32:563-9. [PMID: 24629514 DOI: 10.1016/j.mri.2014.02.010] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2013] [Revised: 07/17/2013] [Accepted: 02/03/2014] [Indexed: 11/19/2022]
Abstract
PURPOSE Electron paramagnetic resonance (EPR) oximetry using variable length multi-probe implantable resonator (IR), was used to investigate the temporal changes in the ischemic and contralateral brain pO2 during stroke in rats. MATERIAL AND METHODS The EPR signal to noise ratio (S/N) of the IR with four sensor loops at a depth of up to 11 mm were compared with direct implantation of lithium phthalocyanine (LiPc, oximetry probe) deposits in vitro. These IRs were used to follow the temporal changes in pO2 at two sites in each hemisphere during ischemia induced by left middle cerebral artery occlusion (MCAO) in rats breathing 30% O2 or 100% O2. RESULTS The S/N ratios of the IRs were significantly greater than the LiPc deposits. A similar pO2 at two sites in each hemisphere prior to the onset of ischemia was observed in rats breathing 30% O2. However, a significant decline in the pO2 of the left cortex and striatum occurred during ischemia, but no change in the pO2 of the contralateral brain was observed. A significant increase in the pO2 of only the contralateral non-ischemic brain was observed in the rats breathing 100% O2. No significant difference in the infarct volume was evident between the animals breathing 30% O2 or 100% O2 during ischemia. CONCLUSIONS EPR oximetry with IRs can repeatedly assess temporal changes in the brain pO2 at four sites simultaneously during stroke. This oximetry approach can be used to test and develop interventions to rescue ischemic tissue by modulating cerebral pO2 during stroke.
Collapse
Affiliation(s)
- Huagang Hou
- EPR Center for Viable Systems, Department of Diagnostic Radiology, The Geisel School of Medicine, 48 Lafayette Street, Lebanon, NH 03766; Norris Cotton Cancer Center, One Medical Center Drive, Dartmouth-Hitchcock Medical Center, Lebanon, NH 03756, USA.
| | - Hongbin Li
- EPR Center for Viable Systems, Department of Diagnostic Radiology, The Geisel School of Medicine, 48 Lafayette Street, Lebanon, NH 03766; Norris Cotton Cancer Center, One Medical Center Drive, Dartmouth-Hitchcock Medical Center, Lebanon, NH 03756, USA
| | - Ruhong Dong
- EPR Center for Viable Systems, Department of Diagnostic Radiology, The Geisel School of Medicine, 48 Lafayette Street, Lebanon, NH 03766; Norris Cotton Cancer Center, One Medical Center Drive, Dartmouth-Hitchcock Medical Center, Lebanon, NH 03756, USA
| | - Nadeem Khan
- EPR Center for Viable Systems, Department of Diagnostic Radiology, The Geisel School of Medicine, 48 Lafayette Street, Lebanon, NH 03766; Norris Cotton Cancer Center, One Medical Center Drive, Dartmouth-Hitchcock Medical Center, Lebanon, NH 03756, USA
| | - Harold Swartz
- EPR Center for Viable Systems, Department of Diagnostic Radiology, The Geisel School of Medicine, 48 Lafayette Street, Lebanon, NH 03766; Norris Cotton Cancer Center, One Medical Center Drive, Dartmouth-Hitchcock Medical Center, Lebanon, NH 03756, USA
| |
Collapse
|
22
|
A Deployable In Vivo EPR Tooth Dosimeter for Triage After a Radiation Event Involving Large Populations. RADIAT MEAS 2011; 46:772-777. [PMID: 21966241 DOI: 10.1016/j.radmeas.2011.03.009] [Citation(s) in RCA: 54] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
In order to meet the potential need for emergency large-scale retrospective radiation biodosimetry following an accident or attack, we have developed instrumentation and methodology for in vivo electron paramagnetic resonance spectroscopy to quantify concentrations of radiation-induced radicals within intact teeth. This technique has several very desirable characteristics for triage, including independence from confounding biologic factors, a non-invasive measurement procedure, the capability to make measurements at any time after the event, suitability for use by non-expert operators at the site of an event, and the ability to provide immediate estimates of individual doses. Throughout development there has been a particular focus on the need for a deployable system, including instrumental requirements for transport and field use, the need for high throughput, and use by minimally trained operators.Numerous measurements have been performed using this system in clinical and other non-laboratory settings, including in vivo measurements with unexposed populations as well as patients undergoing radiation therapies. The collection and analyses of sets of three serially-acquired spectra with independent placements of the resonator, in a data collection process lasting approximately five minutes, provides dose estimates with standard errors of prediction of approximately 1 Gy. As an example, measurements were performed on incisor teeth of subjects who had either received no irradiation or 2 Gy total body irradiation for prior bone marrow transplantation; this exercise provided a direct and challenging test of our capability to identify subjects who would be in need of acute medical care.
Collapse
|
23
|
Williams BB, Dong R, Nicolalde RJ, Matthews TP, Gladstone DJ, Demidenko E, Zaki BI, Salikhov IK, Lesniewski PN, Swartz HM. Physically-based biodosimetry using in vivo EPR of teeth in patients undergoing total body irradiation. Int J Radiat Biol 2011; 87:766-75. [PMID: 21696339 DOI: 10.3109/09553002.2011.583316] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
PURPOSE The ability to estimate individual exposures to radiation following a large attack or incident has been identified as a necessity for rational and effective emergency medical response. In vivo electron paramagnetic resonance (EPR) spectroscopy of tooth enamel has been developed to meet this need. MATERIALS AND METHODS A novel transportable EPR spectrometer, developed to facilitate tooth dosimetry in an emergency response setting, was used to measure upper incisors in a model system, in unirradiated subjects, and in patients who had received total body doses of 2 Gy. RESULTS A linear dose response was observed in the model system. A statistically significant increase in the intensity of the radiation-induced EPR signal was observed in irradiated versus unirradiated subjects, with an estimated standard error of dose prediction of 0.9 ± 0.3 Gy. CONCLUSIONS These results demonstrate the current ability of in vivo EPR tooth dosimetry to distinguish between subjects who have not been irradiated and those who have received exposures that place them at risk for acute radiation syndrome. Procedural and technical developments to further increase the precision of dose estimation and ensure reliable operation in the emergency setting are underway. With these developments EPR tooth dosimetry is likely to be a valuable resource for triage following potential radiation exposure of a large population.
Collapse
Affiliation(s)
- Benjamin B Williams
- Department of Diagnostic Radiology, Dartmouth Physically-based Biodosimetry Center for Medical Countermeasures against Radiation, Dartmouth Medical School, Hanover, New Hampshire, USA.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
24
|
Petryakov S, Samouilov A, Kesselring E, Caia GL, Sun Z, Zweier JL. Dual frequency resonator for 1.2 GHz EPR/16.2 MHz NMR co-imaging. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2010; 205:1-8. [PMID: 20434379 PMCID: PMC2919297 DOI: 10.1016/j.jmr.2010.02.020] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/17/2009] [Revised: 12/21/2009] [Accepted: 02/19/2010] [Indexed: 05/29/2023]
Abstract
The development of a dual frequency resonator that enables both EPR and proton NMR imaging within the same resonator, magnet and gradient system is described. A novel design allows the same resonator to perform both EPR and proton NMR operation without moving resonator cables or switches. The resonator is capable of working at frequencies of 16.18 MHz for proton NMR and 1.2 GHz for EPR and is optimized for isolated rat heart experiments, measuring 22 mm in inner diameter and 19 mm in length. In EPR mode, the resonator functions as a one-loop-two gap resonator, electrically coupled through a half wavelength inverter. In NMR mode, it functions a single turn coil. Using the same loop for both modalities maximizes filling factor at both frequencies. Placing the tuning and switching controls away from the resonator prevents any inadvertent movement that would cause errors of EPR and NMR co-imaging registration. The resonator enabled good quality EPR and proton MRI of isolated rat hearts with precise registration.
Collapse
Affiliation(s)
| | | | | | | | | | - Jay L. Zweier
- Address for correspondence and proofs: Jay L. Zweier, Davis Heart and Lung Research Institute, 473 West 12 Avenue, Room 110G, Columbus, OH 43210-1252.
| |
Collapse
|
25
|
Fattibene P, Callens F. EPR dosimetry with tooth enamel: A review. Appl Radiat Isot 2010; 68:2033-116. [PMID: 20599388 DOI: 10.1016/j.apradiso.2010.05.016] [Citation(s) in RCA: 123] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2010] [Accepted: 05/09/2010] [Indexed: 11/30/2022]
Abstract
When tooth enamel is exposed to ionizing radiation, radicals are formed, which can be detected using electron paramagnetic resonance (EPR) techniques. EPR dosimetry using tooth enamel is based on the (presumed) correlation between the intensity or amplitude of some of the radiation-induced signals with the dose absorbed in the enamel. In the present paper a critical review is given of this widely applied dosimetric method. The first part of the paper is fairly fundamental and deals with the main properties of tooth enamel and some of its model systems (e.g., synthetic apatites). Considerable attention is also paid to the numerous radiation-induced and native EPR signals and the radicals responsible for them. The relevant methods for EPR detection, identification and spectrum analyzing are reviewed from a general point of view. Finally, the needs for solid-state modelling and studies of the linearity of the dose response are investigated. The second part is devoted to the practical implementation of EPR dosimetry using enamel. It concerns specific problems of preparation of samples, their irradiation and spectrum acquisition. It also describes how the dosimetric signal intensity and dose can be retrieved from the EPR spectra. Special attention is paid to the energy dependence of the EPR response and to sources of uncertainties. Results of and problems encountered in international intercomparisons and epidemiological studies are also dealt with. In the final section the future of EPR dosimetry with tooth enamel is analyzed.
Collapse
Affiliation(s)
- Paola Fattibene
- Istituto Superiore di Sanità, Department of Technology and Health, Viale Regina Elena, Rome, Italy.
| | | |
Collapse
|
26
|
Williams BB, Dong R, Kmiec M, Burke G, Demidenko E, Gladstone D, Nicolalde RJ, Sucheta A, Lesniewski P, Swartz HM. Development of in vivo tooth EPR for individual radiation dose estimation and screening. HEALTH PHYSICS 2010; 98:327-38. [PMID: 20065702 PMCID: PMC2821193 DOI: 10.1097/hp.0b013e3181a6de5d] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
The development of in vivo EPR has made it feasible to perform tooth dosimetry measurements in situ, greatly expanding the potential for using this approach for immediate screening after radiation exposures. The ability of in vivo tooth dosimetry to provide estimates of absorbed dose has been established through a series of experiments using unirradiated volunteers with specifically irradiated molar teeth placed in situ within gaps in their dentition and in natural canine teeth of patients who have completed courses of radiation therapy for head and neck cancers. Multiple measurements in patients who have received radiation therapy demonstrate the expected heterogeneous dose distributions. Dose-response curves have been generated using both populations and, using the current methodology and instrument, the standard error of prediction based on single 4.5-min measurements is approximately 1.5 Gy for inserted molar teeth and between 2.0 and 2.5 Gy in the more irregularly shaped canine teeth. Averaging of independent measurements can reduce this error significantly to values near 1 Gy. Developments to reduce these errors are underway, focusing on geometric optimization of the resonators, detector positioning techniques, and optimal data averaging approaches. In summary, it seems plausible that the EPR dosimetry techniques will have an important role in retrospective dosimetry for exposures involving large numbers of individuals.
Collapse
Affiliation(s)
- Benjamin B. Williams
- Dartmouth Medical School, Radiology, 704 Vail, HB 7785, Hanover, NH 03755, UNITED STATES, 603-650-1806, Admin Assistant: 603-650-1784, FAX: 603-650-1717,
| | | | | | | | | | | | | | | | | | | |
Collapse
|
27
|
Pollock JD, Williams BB, Sidabras JW, Grinberg O, Salikhov I, Lesniewski P, Kmiec M, Swartz HM. Surface loop resonator design for in vivo EPR tooth dosimetry using finite element analysis. HEALTH PHYSICS 2010; 98:339-44. [PMID: 20065703 PMCID: PMC4086293 DOI: 10.1097/hp.0b013e3181a6dd08] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/07/2023]
Abstract
Finite element analysis is used to evaluate and design L-band surface loop resonators for in vivo electron paramagnetic resonance (EPR) tooth dosimetry. This approach appears to be practical and useful for the systematic examination and evaluation of resonator configurations to enhance the precision of dose estimates. The effects of loop positioning in the mouth are examined, and it is shown that the sensitivity to loop position along a row of molars is decreased as the loop is moved away from the teeth.
Collapse
|
28
|
Petryakov S, Samouilov A, Chzhan-Roytenberg M, Kesselring E, Sun Z, Zweier JL. Segmented surface coil resonator for in vivo EPR applications at 1.1GHz. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2009; 198:8-14. [PMID: 19268615 PMCID: PMC2919311 DOI: 10.1016/j.jmr.2008.12.014] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/24/2008] [Revised: 12/03/2008] [Accepted: 12/15/2008] [Indexed: 05/21/2023]
Abstract
A four-loop segmented surface coil resonator (SSCR) with electronic frequency and coupling adjustments was constructed with 18mm aperture and loading capability suitable for in vivo Electron Paramagnetic Resonance (EPR) spectroscopy and imaging applications at L-band. Increased sample volume and loading capability were achieved by employing a multi-loop three-dimensional surface coil structure. Symmetrical design of the resonator with coupling to each loop resulted in high homogeneity of RF magnetic field. Parallel loops were coupled to the feeder cable via balancing circuitry containing varactor diodes for electronic coupling and tuning over a wide range of loading conditions. Manually adjusted high Q trimmer capacitors were used for initial tuning with subsequent tuning electronically controlled using varactor diodes. This design provides transparency and homogeneity of magnetic field modulation in the sample volume, while matching components are shielded to minimize interference with modulation and ambient RF fields. It can accommodate lossy samples up to 90% of its aperture with high homogeneity of RF and modulation magnetic fields and can function as a surface loop or a slice volume resonator. Along with an outer coaxial NMR surface coil, the SSCR enabled EPR/NMR co-imaging of paramagnetic probes in living rats to a depth of 20mm.
Collapse
Affiliation(s)
| | | | | | | | | | - Jay L. Zweier
- Corresponding author. Fax: +1 614 247 7845. (J.L. Zweier)
| |
Collapse
|
29
|
Shiba T, Yamato M, Kudou W, Ichikawa K, Yamada KI, Watanabe T, Utsumi H. Analysis of Nitroxyl Spin Probes in Mouse Brain by X-Band ESR with Microdialysis Technique. J Pharm Sci 2008; 97:4101-7. [DOI: 10.1002/jps.21258] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
30
|
Williams BB, Hou H, Grinberg OY, Demidenko E, Swartz HM. High spatial resolution multisite EPR oximetry of transient focal cerebral ischemia in the rat. Antioxid Redox Signal 2007; 9:1691-8. [PMID: 17678442 DOI: 10.1089/ars.2007.1723] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
In vivo electron paramagnetic resonance (EPR) spectroscopy can provide direct noninvasive, continuous, and repeatable measurements of oxygen in tissues. High-spatial-resolution multisite (HSRMS) oximetry is an EPR technique that uses applied magnetic field gradients to extend this capability to multiple implanted probes within the sample and accurately to estimate their respective local pO(2) values. These capabilities are crucial in experiments in which pO(2) varies across space and time and in which information about these variations is needed to describe physiologic and pathophysiologic phenomena and evaluate their responses to interventions such as therapy. One important application is the investigation of transient focal ischemia in the rat brain and the effects of treatment with hyperoxygenation. We used HSRMS oximetry with overmodulation to measure brain tissue oxygenation in a rat stroke model using lithium phthalocyanine as the oxygen probe. Oxygen measurements were made in a small cohort of rats at four implant sites during ischemia and reperfusion after transient focal ischemia initiated by occlusion of the middle cerebral artery. These measurements demonstrate the capabilities of the HSRMS oximetry technique and set the stage for more extensive physiologic studies.
Collapse
Affiliation(s)
- Benjamin B Williams
- Dartmouth EPR Center, Department of Radiology, Dartmouth Medical School, Hanover, New Hampshire 03755, USA.
| | | | | | | | | |
Collapse
|
31
|
Hou H, Grinberg O, Williams B, Grinberg S, Yu H, Alvarenga DL, Wallach H, Buckey J, Swartz HM. The effect of oxygen therapy on brain damage and cerebral pO(2) in transient focal cerebral ischemia in the rat. Physiol Meas 2007; 28:963-76. [PMID: 17664686 DOI: 10.1088/0967-3334/28/8/017] [Citation(s) in RCA: 38] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Abstract
We examined the effect of hyperbaric oxygen (HBO) and normobaric oxygen (NBO) on neurologic damage and brain oxygenation before and after focal cerebral ischemia in rats. A middle cerebral artery occlusion (MCAO)/reperfusion rat model was used. The rats were sacrificed 22 h after reperfusion, and the infarct volume was evaluated. In study A, HBO (2.0 ATA), NBO (100% oxygen) and normobaric air (NBA) were each administered for 60 min in five different rat groups. The sizes of the infarcts after HBO and NBO applied during ischemia were 8.8 +/- 2.8% and 22.8 +/- 3.7% respectively of the ipsilateral non-occluded hemisphere. The infarct size after HBO applied during ischemia was statistically smaller than for NBO and NBA exposure (p < 0.01). In study B, cerebral pO(2) was measured before and after MCAO and HBO exposure (2.0 ATA for 60 min) in six rats using electron paramagnetic resonance (EPR) oximetry. The pO(2) in the ischemic hemisphere fell markedly following ischemia, while the pO(2) in the contralateral hemisphere remained within the normal range. Measurements of the pO(2) performed minutes after HBO exposure did not show an increase in the ischemic or normal hemispheres. The mean relative infarct size was consistent with the changes observed in study A. These data confirm the neuroprotective effects of HBO in cerebral ischemia and indicate that in vivo EPR oximetry can be an effective method to monitor the cerebral oxygenation after oxygen therapy for ischemic stroke. The ability to measure the pO(2) in several sites provides important information that should help to optimize the design of hyperoxic therapies for stroke.
Collapse
Affiliation(s)
- Huagang Hou
- Department of Radiology, Dartmouth Medical School, Hanover, NH, USA
| | | | | | | | | | | | | | | | | |
Collapse
|
32
|
Williams BB, Sucheta A, Dong R, Sakata Y, Iwasaki A, Burke G, Grinberg O, Lesniewski P, Kmiec M, Swartz HM. Experimental Procedures for Sensitive and Reproducible In Situ EPR Tooth Dosimetry. RADIAT MEAS 2007; 42:1094-1098. [PMID: 18591989 DOI: 10.1016/j.radmeas.2007.05.001] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
In vivo electron paramagnetic resonance (EPR) tooth dosimetry provides a means for non-invasive retrospective assessment of personal radiation exposure. While there is a clear need for such capabilities following radiation accidents, the most pressing need for the development of this technology is the heightened likelihood of terrorist events or nuclear conflicts. This technique will enable such measurements to be made at the site of an incident, while the subject is present, to assist emergency personnel as they perform triage for the affected population. At Dartmouth Medical School this development is currently being tested with normal volunteers with irradiated teeth placed in their mouths and with patients who have undergone radiation therapy. Here we describe progress in practical procedures to provide accurate and reproducible in vivo dose estimates.
Collapse
|
33
|
Lund LP, Timmins GS. Melanoma, long wavelength ultraviolet and sunscreens: Controversies and potential resolutions. Pharmacol Ther 2007; 114:198-207. [PMID: 17376535 DOI: 10.1016/j.pharmthera.2007.01.007] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2007] [Accepted: 01/30/2007] [Indexed: 12/31/2022]
Abstract
Although sunlight is known to cause melanoma, there has been considerable controversy as to the importance of short (UVB) and long (UVA) ultraviolet (UV) wavelengths in causing melanoma, leading to uncertainty in how best to prevent this cancer. This uncertainty has been compounded by the difficulties in assaying the UVA protection abilities of sunscreens, as compared to widely accepted measures of UVB screening by the sun protection factor (SPF). This review discusses the controversies surrounding UVA causation of melanoma in both human and animal models and the use of sunscreens to prevent melanoma. In addition, it details the development of an electron paramagnetic resonance (EPR) technique, initially used to determine the wavelength dependence (or action spectrum) of intramelanocyte radical generation to resolve these controversies in the Xiphophorus model. It is shown how this EPR technique allows a sunscreen protection factor to be determined, that is weighted to the melanocyte, and how this also allows study of the wavelength-dependent screening ability of sunscreens.
Collapse
Affiliation(s)
- Leslie P Lund
- Department of Pharmaceutical Sciences, College of Pharmacy, University of New Mexico Health Sciences Center, Albuquerque, NM 87131, USA
| | | |
Collapse
|
34
|
Matsumoto S, Yamada K, Hirata H, Yasukawa K, Hyodo F, Ichikawa K, Utsumi H. Advantageous application of a surface coil to EPR irradiation in overhauser-enhanced MRI. Magn Reson Med 2007; 57:806-11. [PMID: 17390363 DOI: 10.1002/mrm.21198] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
The present study describes the advantageous application of a surface coil to electron paramagnetic resonance (EPR) irradiation in Overhauser-enhanced MRI (OMRI). OMRI is a double-resonance method for imaging free radicals based on the Overhauser effect. Proton NMR images are recorded without and with EPR irradiation of the free radical resonance, which results in a difference proton image that shows signal enhancement in spatial regions that contain the free radical. To obtain good signal enhancement in OMRI, very high RF power and a long EPR irradiation time are required. To improve sensitivity and shorten the image acquisition time, especially for localized (and topical) applications, we developed and tested a surface-coil-type EPR irradiation coil. Theoretical calculations and experimental data showed that EPR irradiation through the surface coil could ameliorate the localized Overhauser enhancement, which was related to the ratio of B(1) surface coil/B(1) volume coil in the region of interest (ROI), as expected. The increased sensitivity could also be converted into a shortened EPR irradiation time, resulting in fast data acquisition. For biomedical applications, the use of a surface coil (as opposed to a conventional volume coil) could decrease the total RF power deposition in the sample required to obtain the same Overhauser enhancement in the ROI.
Collapse
Affiliation(s)
- Shingo Matsumoto
- Department of Biofunctional Science, Graduate School of Pharmaceutical Sciences, Kyushu University, Fukuoka, Japan
| | | | | | | | | | | | | |
Collapse
|
35
|
Wood SR, Berwick M, Ley RD, Walter RB, Setlow RB, Timmins GS. UV causation of melanoma in Xiphophorus is dominated by melanin photosensitized oxidant production. Proc Natl Acad Sci U S A 2006; 103:4111-5. [PMID: 16537493 PMCID: PMC1449655 DOI: 10.1073/pnas.0511248103] [Citation(s) in RCA: 92] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
Abstract
Controversy continues both as to which wavelengths of sunlight cause melanoma and the mechanisms by which these different wavelengths act. Direct absorption of UVB by DNA is central in albino animal models, but melanin-pigmented models have shown major contributions by wavelengths longer than UVB that are thought to be mediated by photosensitized oxidant production. The only model for which the action spectrum of melanoma causation is known is a genetically melanoma-susceptible specific cross of Xiphophorus fish. We used electron paramagnetic resonance to quantitatively detect the UV induction of reactive melanin radicals in situ in the melanin-containing cells in the skin of this model and derived the action spectrum for melanin-photosensitized oxidant production (Phi(ox)). This action spectrum was identical to that for melanoma induction (Phi(mel)). These results confirm the hypothesis that melanin-photosensitized radical production is the major causative step of melanoma in this model and demonstrate that the wavelengths and mechanisms of melanoma causation in different models are dependent on the presence of melanin. This approach should be applicable to humans, thus providing an accurate surrogate for Phi(mel) for prevention studies.
Collapse
Affiliation(s)
- Simon R. Wood
- *Division of Pharmaceutical Sciences, College of Pharmacy
| | | | - Ronald D. Ley
- Department of Cell Biology and Physiology, University of New Mexico Health Sciences Center, Albuquerque, NM 87131
| | - Ronald B. Walter
- Department of Chemistry and Biochemistry, Molecular Biosciences Research Group, Texas State University, 601 University Drive, San Marcos, TX 78766; and
| | - Richard B. Setlow
- Biology Department, Brookhaven National Laboratory, Upton, NY 11973-5000
- To whom correspondence may be addressed. E-mail:
or
| | - Graham S. Timmins
- *Division of Pharmaceutical Sciences, College of Pharmacy
- To whom correspondence may be addressed. E-mail:
or
| |
Collapse
|
36
|
Salikhov I, Walczak T, Lesniewski P, Khan N, Iwasaki A, Comi R, Buckey J, Swartz HM. EPR spectrometer for clinical applications. Magn Reson Med 2006; 54:1317-20. [PMID: 16193470 DOI: 10.1002/mrm.20689] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
This article describes an EPR spectrometer specifically designed and constructed for EPR spectroscopy in humans. The spectrometer is based on a permanent magnet, suitable for measurements at 1200 MHz. The magnet has a full 50 cm gap between the poles, which facilitates accurate and comfortable placement of the subject for the EPR measurement at any location on the human body. The bridge includes features to facilitate clinical operations, including an indicator for phasing of the reference arm and a 2 level RF amplifier. Resonators with holders for each type and site of measurement have been developed that comfortably position the resonator and the patient and prevent artifacts due to motion. The initial applications for which the spectrometer has been designed are for oximetry using loops on the surface, oximetry using implanted resonators for measuring deep sites, and measurements in the teeth for determination of exposures to clinically significant doses of ionizing radiation.
Collapse
Affiliation(s)
- I Salikhov
- EPR Center for the Study of Viable Systems, Department of Diagnostic Radiology, Dartmouth Medical School, Hanover, New Hampshire 03755, USA
| | | | | | | | | | | | | | | |
Collapse
|
37
|
Swartz HM, Iwasaki A, Walczak T, Demidenko E, Salikhov I, Khan N, Lesniewski P, Thomas J, Romanyukha A, Schauer D, Starewicz P. In vivo EPR dosimetry to quantify exposures to clinically significant doses of ionising radiation. RADIATION PROTECTION DOSIMETRY 2006; 120:163-70. [PMID: 16644994 DOI: 10.1093/rpd/nci554] [Citation(s) in RCA: 38] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/07/2023]
Abstract
As a result of terrorism, accident or war, populations potentially can be exposed to doses of ionising radiation that could cause direct clinical effects within days or weeks. There is a critical need to determine the magnitude of the exposure to individuals so that those with significant risk can have appropriate procedures initiated immediately, while those without a significant probability of acute effects can be reassured and removed from the need for further consideration in the medical/emergency system. It is extremely unlikely that adequate dosemeters will be worn by the potential victims, and it also will be unlikely that prompt and accurate dose reconstruction at the level of individuals will be possible. Therefore, there is a critical need for a method to measure the dose from radiation-induced effects that occur within the individual. In vivo EPR measurements of radiation-induced changes in the enamel of teeth is a method, perhaps the only such method, which can differentiate among doses sufficiently to classify individuals into categories for treatment with sufficient accuracy to facilitate decisions on medical treatment. In its current state, the in vivo EPR dosemeter can provide estimates of absorbed dose of +/- 0.5 Gy in the range from 1 to >10 Gy. The lower limit and the precision are expected to improve, with improvements in the resonator and the algorithm for acquiring and calculating the dose. In its current state of development, the method is already sufficient for decision-making action for individuals with regard to acute effects from exposure to ionising radiation for most applications related to terrorism, accidents or nuclear warfare.
Collapse
Affiliation(s)
- Harold M Swartz
- EPR Center for Viable Systems, Dartmouth Medical School, 703 Vail, Hanover, NH 03755, USA.
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|