Xie X, Truong T, Huang S, Johnston SM, Hovanski S, Robinson A, Webber KGI, Lin HJL, Mun DG, Pandey A, Kelly RT. Multicolumn Nanoflow Liquid Chromatography with Accelerated Offline Gradient Generation for Robust and Sensitive Single-Cell Proteome Profiling. Anal Chem 2024; 96:10534-10542. [PMID: 38915247 PMCID: PMC11482043 DOI: 10.1021/acs.analchem.4c00878] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/26/2024]
Abstract
Peptide separations that combine high sensitivity, robustness, peak capacity, and throughput are essential for extending bottom-up proteomics to smaller samples including single cells. To this end, we have developed a multicolumn nanoLC system with offline gradient generation. One binary pump generates gradients in an accelerated fashion to support multiple analytical columns, and a single trap column interfaces with all analytical columns to reduce required maintenance and simplify troubleshooting. A high degree of parallelization is possible, as one sample undergoes separation while the next sample plus its corresponding mobile phase gradient are transferred into the storage loop and a third sample is loaded into a sample loop. Selective offline elution from the trap column into the sample loop prevents salts and hydrophobic species from entering the analytical column, thus greatly enhancing column lifetime and system robustness. With this design, samples can be analyzed as fast as every 20 min at a flow rate of just 40 nL/min with close to 100% MS utilization time and continuously for as long as several months without column replacement. We utilized the system to analyze the proteomes of single cells from a multiple myeloma cell line upon treatment with the immunomodulatory imide drug lenalidomide.
Collapse
Affiliation(s)
- Xiaofeng Xie
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, Utah 84602, United States
- MicrOmics Technologies, LLC, Spanish Fork, Utah 84660, United States
| | - Thy Truong
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, Utah 84602, United States
- MicrOmics Technologies, LLC, Spanish Fork, Utah 84660, United States
| | - Siqi Huang
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, Utah 84602, United States
| | - S Madisyn Johnston
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, Utah 84602, United States
| | - Simon Hovanski
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, Utah 84602, United States
| | - Abigail Robinson
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, Utah 84602, United States
| | - Kei G I Webber
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, Utah 84602, United States
| | - Hsien-Jung L Lin
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, Utah 84602, United States
| | - Dong-Gi Mun
- Department of Laboratory Medicine and Pathology, Mayo Clinic, Rochester, Minnesota 55905, United States
| | - Akhilesh Pandey
- Department of Laboratory Medicine and Pathology, Mayo Clinic, Rochester, Minnesota 55905, United States
- Manipal Academy of Higher Education, Manipal, Karnataka 576104, India
| | - Ryan T Kelly
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, Utah 84602, United States
- MicrOmics Technologies, LLC, Spanish Fork, Utah 84660, United States
| |
Collapse
|
2
|
Lakis R, Sauvage FL, Pinault E, Marquet P, Saint-Marcoux F, El Balkhi S. Absolute Quantification of Human Serum Albumin Isoforms by Internal Calibration Based on a Top-Down LC-MS Approach. Anal Chem 2024; 96:746-755. [PMID: 38166371 DOI: 10.1021/acs.analchem.3c03933] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2024]
Abstract
Well-characterized biomarkers using reliable quantitative methods are essential for the management of various pathologies such as diabetes, kidney, and liver diseases. Human serum albumin (HSA) isoforms are gaining interest as biomarkers of advanced liver pathologies. In view of the structural alterations observed for HSA, insights into its isoforms are required to establish them as reliable biomarkers. Therefore, a robust absolute quantification method seems necessary. In this study, we developed and validated a far more advanced top-down liquid chromatography-mass spectrometry (LC-MS) method for the absolute quantification of HSA isoforms, using myoglobin (Mb) as an internal standard for quantification and for mass recalibration. Two different quantification approaches were investigated based on peak integration from the deconvoluted spectrum and extracted ion chromatogram (XIC). The protein mixture human serum albumin/myoglobin eluted in well-shaped separated peaks. Mb allowed a systematic mass recalibration for every sample, resulting in extremely low mass deviations compared to conventional deconvolution-based methods. In total, eight HSA isoforms of interest were quantified. Specific-isoform calibration curves showing good linearity were obtained by using the deconvoluted peaks. Noticeably, the HSA ionization behavior appeared to be isoform-dependent, suggesting that the use of an enriched isoform solution as a calibration standard for absolute quantification studies of HSA isoforms is necessary. Good repeatability, reproducibility, and accuracy were observed, with better sensitivity for samples with low albumin concentrations compared to routine biochemical assays. With a relatively simple workflow, the application of this method for absolute quantification shows great potential, especially for HSA isoform studies in a clinical context, where a high-throughput method and sensitivity are needed.
Collapse
Affiliation(s)
- Roy Lakis
- Pharmacology & Transplantation (P&T), Université de Limoges, INSERM U1248, Limoges 87000, France
| | - François-Ludovic Sauvage
- Pharmacology & Transplantation (P&T), Université de Limoges, INSERM U1248, Limoges 87000, France
| | - Emilie Pinault
- Pharmacology & Transplantation (P&T), Université de Limoges, INSERM U1248, Limoges 87000, France
| | - Pierre Marquet
- Pharmacology & Transplantation (P&T), Université de Limoges, INSERM U1248, Limoges 87000, France
- Department of Pharmacology, Toxicology and Pharmacovigilance, CHU Limoges, Limoges 87000, France
| | - Franck Saint-Marcoux
- Pharmacology & Transplantation (P&T), Université de Limoges, INSERM U1248, Limoges 87000, France
- Department of Pharmacology, Toxicology and Pharmacovigilance, CHU Limoges, Limoges 87000, France
| | - Souleiman El Balkhi
- Pharmacology & Transplantation (P&T), Université de Limoges, INSERM U1248, Limoges 87000, France
- Department of Pharmacology, Toxicology and Pharmacovigilance, CHU Limoges, Limoges 87000, France
| |
Collapse
|
3
|
Liu FC, Ridgeway ME, Wootton CA, Theisen A, Panczyk EM, Meier F, Park MA, Bleiholder C. Top-Down Protein Analysis by Tandem-Trapped Ion Mobility Spectrometry/Mass Spectrometry (Tandem-TIMS/MS) Coupled with Ultraviolet Photodissociation (UVPD) and Parallel Accumulation/Serial Fragmentation (PASEF) MS/MS Analysis. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2023; 34:2232-2246. [PMID: 37638640 PMCID: PMC11162218 DOI: 10.1021/jasms.3c00187] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/29/2023]
Abstract
"Top-down" proteomics analyzes intact proteins and identifies proteoforms by their intact mass as well as the observed fragmentation pattern in tandem mass spectrometry (MS/MS) experiments. Recently, hybrid ion mobility spectrometry-mass spectrometry (IM/MS) methods have gained traction for top-down experiments, either by allowing top-down analysis of individual isomers or alternatively by improving signal/noise and dynamic range for fragment ion assignment. We recently described the construction of a tandem-trapped ion mobility spectrometer/mass spectrometer (tandem-TIMS/MS) coupled with an ultraviolet (UV) laser and demonstrated a proof-of-principle for top-down analysis by UV photodissociation (UVPD) at 2-3 mbar. The present work builds on this with an exploration of a top-down method that couples tandem-TIMS/MS with UVPD and parallel-accumulation serial fragmentation (PASEF) MS/MS analysis. We first survey types and structures of UVPD-specific fragment ions generated in the 2-3 mbar pressure regime of our instrument. Notably, we observe UVPD-induced fragment ions with multiple conformations that differ from those produced in the absence of UV irradiation. Subsequently, we discuss how MS/MS spectra of top-down fragment ions lend themselves ideally for probability-based scoring methods developed in the bottom-up proteomics field and how the ability to record automated PASEF-MS/MS spectra resolves ambiguities in the assignment of top-down fragment ions. Finally, we describe the coupling of tandem-TIMS/MS workflows with UVPD and PASEF-MS/MS analysis for native top-down protein analysis.
Collapse
Affiliation(s)
- Fanny C. Liu
- Department of Chemistry and Biochemistry, Florida State University, Tallahassee, FL 32304, USA
| | | | | | | | | | - Florian Meier
- Functional Proteomics, Jena University Hospital, 07747 Jena, Germany
| | | | - Christian Bleiholder
- Institute of Molecular Biophysics, Florida State University, Tallahassee, FL 32304, USA
| |
Collapse
|
4
|
Shih CH, Ke CH, Hsiao CC. Liquid chromatography on a centrifugal platform for separation and collection of water-soluble dyes. J Chromatogr A 2023; 1705:464211. [PMID: 37480725 DOI: 10.1016/j.chroma.2023.464211] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2023] [Revised: 07/09/2023] [Accepted: 07/11/2023] [Indexed: 07/24/2023]
Abstract
A reversed-phase chromatographic process is developed on a centrifugal platform to separate and collect water-soluble dyes from a mixture. A separation column filled with C18-reversed phase silica gel was used to separate the components from a mixture and the eluate was collected by a series of collecting chambers. The purified components can then be identified and extracted from the collecting chambers. The effects of the silica gel's particle size (7-10, 20-45, and 46-63 µm) and the platform's rotational speed (1000, 1500, 2000 RPM) on the separation and collection efficiency were investigated. Experimental results showed that dye separation could be well performed in the column with smaller-sized silica gels (7-10 µm) under a low rotational speed (1000 RPM). However, for the eluate collection, the high eluent flowrate and long processing time resulted in a convective band-broadening problem in the collecting chambers, which affected the recovery ratio of the dyes. Experimental results showed that the convective band broadening effect can be reduced by reducing the flowrate, shortening the collecting time, and switching the eluent to a different composition. The best recovery ratio of the dyes in the current design can be achieved by using the column with a powder size distribution of 46-63 µm and operating at the rotational speed of 1500 RPM. This platform can process a sample volume of 1 μL and the processing time is about 30 min. Since the only instrument used is a motor, the complete chromatographic process, from separation to fraction collection, can be carried out on a centrifugal platform at a low cost.
Collapse
Affiliation(s)
- Chih-Hsin Shih
- Department of Chemical Engineering, Feng Chia University, 100 Wenhua Road, Taichung 40724, Taiwan.
| | - Chao-Hui Ke
- Department of Chemical Engineering, Feng Chia University, 100 Wenhua Road, Taichung 40724, Taiwan
| | - Chih-Chien Hsiao
- Department of Chemical Engineering, Feng Chia University, 100 Wenhua Road, Taichung 40724, Taiwan
| |
Collapse
|
5
|
Escudero-Cernuda S, García de Pablos C, Celis FC, Fernández-Sánchez ML, Encinar JR. Certification of protein biomarker standards using element MS and generic standards: Application to human cytokines. Anal Chim Acta 2023; 1251:341002. [PMID: 36925291 DOI: 10.1016/j.aca.2023.341002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2022] [Revised: 02/11/2023] [Accepted: 02/21/2023] [Indexed: 02/27/2023]
Abstract
The availability of protein standards and methods for their characterization, quantification, and purity assessment are currently a bottleneck in absolute quantitative proteomics. In this work, we introduce an absolute quantitative analytical strategy based on ICP-MS sulfur detection that uses sulfate as generic standard to quantify and certify the mass purity of protein standards. The methodology combines capillary chromatographic separation with parallel detection with ICP-MS and ESI-MS to determine proteoforms concentration and identity, respectively. The workability of the methodology was demonstrated using recombinant human cytokine standards IP-10 and Flt3L (2 batches), which are relevant biomarkers for carcinoma or inflammatory diseases. Every key factor (transport efficiency, column recovery, signal stability and internal standard suitability) was taken into account and certified BSA standard was used as quality control for validation purposes. Protein quantification values and resulting mass purity certification of IP-10 and one batch of Flt3L were very high (100 and 86%, respectively). Lower mass purity obtained for another batch of Flt3L (<70%) concurred with the finding of significant proteoforms resulted from oxidation processes as observed by parallel ESI-MS.
Collapse
Affiliation(s)
- Sara Escudero-Cernuda
- Department of Physical and Analytical Chemistry, University of Oviedo, Avda. Julián Clavería 8, Oviedo, 33006, Spain
| | - Carlos García de Pablos
- Department of Physical and Analytical Chemistry, University of Oviedo, Avda. Julián Clavería 8, Oviedo, 33006, Spain
| | - Francisco Calderón Celis
- Department of Physical and Analytical Chemistry, University of Oviedo, Avda. Julián Clavería 8, Oviedo, 33006, Spain.
| | - M Luisa Fernández-Sánchez
- Department of Physical and Analytical Chemistry, University of Oviedo, Avda. Julián Clavería 8, Oviedo, 33006, Spain.
| | - Jorge Ruiz Encinar
- Department of Physical and Analytical Chemistry, University of Oviedo, Avda. Julián Clavería 8, Oviedo, 33006, Spain
| |
Collapse
|
6
|
Nonspecific adsorption evaluation and general minimization strategy in peptide analysis based on ultra-performance liquid chromatography-mass spectrometry. Se Pu 2022; 40:616-624. [PMID: 35791600 PMCID: PMC9404093 DOI: 10.3724/sp.j.1123.2021.12012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
蛋白质组学技术在多肽和蛋白质类新型治疗药物的开发、临床诊断生物标志物的深入发掘中应用广泛。然而,多肽和蛋白质类大分子的非特异性吸附性质给分析方法的开发带来极大挑战,亟须一种通用型的策略去评估和降低非特异吸附对超高效液相色谱-质谱(UPLC-MS)大分子检测造成的负面影响。研究以牛血清白蛋白(BSA)为模型,探讨其酶解后多肽组理化性质与吸附程度之间的相关性;根据肽段的响应和吸附程度设计分级策略;针对高响应、强吸附的Class Ⅱ类肽段,从样品制备中离心管、进样瓶的选择,乃至液相色谱系统中色谱柱固定相、流速、梯度、柱温、洗针液的选择全过程设计试验,探讨非特异吸附的影响因素及其通用型最小化策略。结果显示,肽段的被吸附程度与其理化参数HPLC指数(HPLC Index)、肽段长度等显著相关(p<0.05),但仅凭上述参数仅能解释30%肽段的被吸附程度。改性的聚丙烯材料可使肽段溶液在储存或前处理过程中获得较高的回收率(24 h内回收率大于80%)。在对液相色谱条件的考察和优化过程中发现,C8填料的色谱柱、高流速、缓梯度以及强洗针液,可使残留量降至最低(降低为原来的1/150)。柱温对残留的影响在肽段间存在较大个体差异,需要对不同的肽段具体分析以得到较少量的残留。研究以详实的数据考察并最小化模型肽段组在分析过程中的非特异吸附,提示了蛋白质类大分子药物分析方法建立中应重点关注的影响因素及其有效的解决方案。
Collapse
|
7
|
Liu FC, Kirk SR, Caldwell KA, Pedrete T, Meier F, Bleiholder C. Tandem Trapped Ion Mobility Spectrometry/Mass Spectrometry (tTIMS/MS) Reveals Sequence-Specific Determinants of Top-Down Protein Fragment Ion Cross Sections. Anal Chem 2022; 94:8146-8155. [PMID: 35621336 PMCID: PMC10032035 DOI: 10.1021/acs.analchem.1c05171] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Abstract
Top-down proteomics provides a straightforward approach to the level of proteoforms but remains technologically challenging. Using ion mobility spectrometry/mass spectrometry (IMS/MS) to separate top-down fragment ions improves signal/noise and dynamic range. Such applications, however, do not yet leverage the primary information obtained from IMS/MS, which is the characterization of the fragment ion structure by the measured momentum transfer cross sections. Here, we perform top-down analysis of intact proteins and assemblies using our tandem trapped ion mobility spectrometer/mass spectrometer (tTIMS/MS) and compile over 1400 cross section values of fragment ions. Our analysis reveals that most fragment ions exhibit multiple, stable conformations similar to those of intact polypeptides and proteins. The data further indicate that the conformational heterogeneity is strongly influenced by the amino acid sequences of the fragment ions. Moreover, time-resolved tTIMS/MS experiments reveal that conformations of top-down fragment ions can be metastable on the timescale of ion mobility measurements. Taken together, our analysis indicates that top-down fragment ions undergo a folding process in the gas phase and that this folding process can lead to kinetic trapping of intermediate states in ion mobility measurements. Hence, because the folding free energy surface of a polypeptide ion is encoded by its amino acid sequence and charge state, our analysis suggests that cross sections can be exploited as sequence-specific determinants of top-down fragment ions.
Collapse
Affiliation(s)
- Fanny C. Liu
- Department of Chemistry and Biochemistry, Florida State University, Tallahassee, FL 32306-4390, USA
| | - Samuel R. Kirk
- Department of Chemistry and Biochemistry, Florida State University, Tallahassee, FL 32306-4390, USA
| | - Kirsten A. Caldwell
- Department of Chemistry and Biochemistry, Florida State University, Tallahassee, FL 32306-4390, USA
| | - Thais Pedrete
- Department of Chemistry and Biochemistry, Florida State University, Tallahassee, FL 32306-4390, USA
| | - Florian Meier
- Functional Proteomics, Jena University Hospital, 07747 Jena, Germany
| | - Christian Bleiholder
- Department of Chemistry and Biochemistry, Florida State University, Tallahassee, FL 32306-4390, USA
- Institute of Molecular Biophysics, Florida State University, Tallahassee, FL 32306-4390, USA
- Corresponding Author
| |
Collapse
|
8
|
|
9
|
Nosti AJ, Barrio LC, Calderón-Celis F, Soldado A, Encinar JR. Absolute quantification of proteins using element mass spectrometry and generic standards. J Proteomics 2022; 256:104499. [DOI: 10.1016/j.jprot.2022.104499] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2021] [Accepted: 01/21/2022] [Indexed: 10/19/2022]
|
10
|
Lone JK, Lekha MA, Bharadwaj RP, Ali F, Pillai MA, Wani SH, Yasin JK, Chandrashekharaiah KS. Multimeric Association of Purified Novel Bowman-Birk Inhibitor From the Medicinal Forage Legume Mucuna pruriens (L.) DC. FRONTIERS IN PLANT SCIENCE 2021; 12:772046. [PMID: 34899797 PMCID: PMC8655843 DOI: 10.3389/fpls.2021.772046] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/07/2021] [Accepted: 10/22/2021] [Indexed: 06/14/2023]
Abstract
A Bowman-Birk protease, i.e., Mucuna pruriens trypsin inhibitor (MPTI), was purified from the seeds by 55.702-fold and revealed a single trypsin inhibitor on a zymogram with a specific activity of 202.31 TIU/mg of protein. On sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) under non-reducing conditions, the protease trypsin inhibitor fraction [i.e., trypsin inhibitor non-reducing (TINR)] exhibited molecular weights of 74 and 37 kDa, and under reducing conditions [i.e., trypsin inhibitor reducing (TIR)], 37 and 18 kDa. TINR-37 revealed protease inhibitor activity on native PAGE and 37 and 18 kDa protein bands on SDS-PAGE. TINR-74 showed peaks corresponding to 18.695, 37.39, 56.085, and 74.78 kDa on ultra-performance liquid chromatography (UPLC) coupled with electrospray ionization/quadrupole time-of-flight-mass spectrometry (ESI/QTOF-MS). Similarly, TINR-37 displayed 18.695 and 37.39 kDa peaks. Furthermore, TIR-37 and TIR-18 exhibited peaks corresponding to 37.39 and 18.695 kDa. Multiple peaks observed by the UPLC-ESI/QTOF analysis revealed the multimeric association, confirming the characteristic and functional features of Bowman-Birk inhibitors (BBIs). The multimeric association helps to achieve more stability, thus enhancing their functional efficiency. MPTI was found to be a competitive inhibitor which again suggested that it belongs to the BBI family of inhibitors, displayed an inhibitor constant of 1.3 × 10-6 M, and further demonstrates potent anti-inflammatory activity. The study provided a comprehensive basis for the identification of multimeric associates and their therapeutic potential, which could elaborate the stability and functional efficiency of the MPTI in the native state from M. pruriens.
Collapse
Affiliation(s)
- Jafar K. Lone
- Department of Studies and Research in Biochemistry, Mangalore University, Konaje, India
| | - Mandapanda A. Lekha
- Department of Studies and Research in Biochemistry, Mangalore University, Konaje, India
| | - Rajiv P. Bharadwaj
- Department of Studies and Research in Biochemistry, Mangalore University, Konaje, India
| | - Fasil Ali
- Department of Studies and Research in Biochemistry, Mangalore University, Konaje, India
| | - M. Arumugam Pillai
- Department of Plant Breeding and Genetics, Agricultural College and Research Institute, Tamil Nadu Agricultural University, Tuticorin, India
| | - Shabir H. Wani
- Mountain Research Centre For Field Crops, Sher-e-Kashmir University of Agricultural Sciences and Technology of Kashmir, Srinagar, India
| | - Jeshima Khan Yasin
- Division of Genomic Resources, Indian Council of Agricultural Research (ICAR)-National Bureau of Plant Genetic Resources, New Delhi, India
| | | |
Collapse
|
11
|
Melby JA, Roberts DS, Larson EJ, Brown KA, Bayne EF, Jin S, Ge Y. Novel Strategies to Address the Challenges in Top-Down Proteomics. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2021; 32:1278-1294. [PMID: 33983025 PMCID: PMC8310706 DOI: 10.1021/jasms.1c00099] [Citation(s) in RCA: 100] [Impact Index Per Article: 33.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
Top-down mass spectrometry (MS)-based proteomics is a powerful technology for comprehensively characterizing proteoforms to decipher post-translational modifications (PTMs) together with genetic variations and alternative splicing isoforms toward a proteome-wide understanding of protein functions. In the past decade, top-down proteomics has experienced rapid growth benefiting from groundbreaking technological advances, which have begun to reveal the potential of top-down proteomics for understanding basic biological functions, unraveling disease mechanisms, and discovering new biomarkers. However, many challenges remain to be comprehensively addressed. In this Account & Perspective, we discuss the major challenges currently facing the top-down proteomics field, particularly in protein solubility, proteome dynamic range, proteome complexity, data analysis, proteoform-function relationship, and analytical throughput for precision medicine. We specifically review the major technology developments addressing these challenges with an emphasis on our research group's efforts, including the development of top-down MS-compatible surfactants for protein solubilization, functionalized nanoparticles for the enrichment of low-abundance proteoforms, strategies for multidimensional chromatography separation of proteins, and a new comprehensive user-friendly software package for top-down proteomics. We have also made efforts to connect proteoforms with biological functions and provide our visions on what the future holds for top-down proteomics.
Collapse
Affiliation(s)
- Jake A Melby
- Department of Chemistry, University of Wisconsin-Madison, Madison, Wisconsin 53706, United States
| | - David S Roberts
- Department of Chemistry, University of Wisconsin-Madison, Madison, Wisconsin 53706, United States
| | - Eli J Larson
- Department of Chemistry, University of Wisconsin-Madison, Madison, Wisconsin 53706, United States
| | - Kyle A Brown
- Department of Chemistry, University of Wisconsin-Madison, Madison, Wisconsin 53706, United States
- Department of Surgery, University of Wisconsin-Madison, Madison, Wisconsin 53705, United States
| | - Elizabeth F Bayne
- Department of Chemistry, University of Wisconsin-Madison, Madison, Wisconsin 53706, United States
| | - Song Jin
- Department of Chemistry, University of Wisconsin-Madison, Madison, Wisconsin 53706, United States
| | - Ying Ge
- Department of Chemistry, University of Wisconsin-Madison, Madison, Wisconsin 53706, United States
- Department of Cell and Regenerative Biology, University of Wisconsin-Madison, Madison, Wisconsin 53705, United States
- Human Proteomics Program, University of Wisconsin-Madison, Madison, Wisconsin 53705, United States
| |
Collapse
|
12
|
Kobayashi H, Wada H, Imai K. Phenyl-bonded monolithic silica capillary column liquid chromatographic separation and detection of fluorogenic derivatized intact proteins. Biomed Chromatogr 2021; 35:e5078. [PMID: 33491229 DOI: 10.1002/bmc.5078] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2020] [Revised: 01/18/2021] [Accepted: 01/21/2021] [Indexed: 12/31/2022]
Abstract
Prior to the identification of proteins for proteomics analysis in human cells, separation of fluorogenic derivatized proteins with a fluorogenic reagent, 7-chloro-N-[2-(dimethylamino)ethyl]-2,1,3-benzoxadiazole-4-sulfonamide, has typically been performed by using a conventional reversed-phase HPLC column. However, the number of proteins in human cells (HepaRG) that are separated by this conventional approach is limited to approximately 500. In this study, a nanoflow liquid chromatography system with an evaluated phenyl-bonded monolithic silica capillary column (0.1 mm i.d., 700 mm length) was used to increase the number of separated fluorogenic derivatized proteins. This system was used to separate derivatized human cell proteins (K562) and yeast (Saccharomyces cerevisiae) proteins as model cell proteomes. More than 1,300 protein peaks were separated/detected from both cell proteomes. We present a straightforward comparison of multiple separation profiles using a novel chromatogram display approach, termed the "spiderweb" chromatogram. In addition, to validate that the detected peaks are derived from proteins, a mass spectrometer was connected to the capillary column and deconvolution of the obtained mass spectra was performed. Furthermore, different molecular weight distribution profiles of the expressed proteins were observed between the two cell proteomes.
Collapse
Affiliation(s)
- Hiroshi Kobayashi
- Laboratory of Proteomics Analysis, Research Institute of Pharmaceutical Sciences, Musashino University, Tokyo, Japan.,R&D group, Shinwa Chemical Industries Ltd, Kyoto, Japan
| | - Hiroo Wada
- R&D group, Shinwa Chemical Industries Ltd, Kyoto, Japan
| | - Kazuhiro Imai
- Laboratory of Proteomics Analysis, Research Institute of Pharmaceutical Sciences, Musashino University, Tokyo, Japan
| |
Collapse
|
13
|
Bupp CR, Wirth MJ. Making Sharper Peaks for Reverse-Phase Liquid Chromatography of Proteins. ANNUAL REVIEW OF ANALYTICAL CHEMISTRY (PALO ALTO, CALIF.) 2020; 13:363-380. [PMID: 32109149 DOI: 10.1146/annurev-anchem-061318-115009] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
Protein separations have gained increasing interest over the past two decades owing to the dramatic growth of proteins as therapeutics and the completion of the Human Genome Project. About every decade, the field of protein high-performance liquid chromatography (HPLC) seems to mature, having reached what appears to be a theoretical limit. But then scientists well versed in the basic principles of HPLC invented a way around the limit, generating another decade of exciting progress. There is still the need for higher resolution and better compatibility with mass spectrometry because it is an essential tool for identification of proteins and their modifications. To make advances, the fundamental principles need to be understood. This review covers recent advances and current needs in the context of the principles that underlie the many contributions to peak broadening.
Collapse
Affiliation(s)
- Charles R Bupp
- Department of Chemistry, Purdue University, West Lafayette, Indiana 47907, USA;
| | - Mary J Wirth
- Department of Chemistry, Purdue University, West Lafayette, Indiana 47907, USA;
| |
Collapse
|
14
|
Xia H, Wang L, Li C, Tian B, Li Q, Zhao H, Bai Q. Synthesis of fully porous silica microspheres with high specific surface area for fast HPLC separation of intact proteins and digests of ovalbumin. Mikrochim Acta 2020; 187:382. [PMID: 32529294 DOI: 10.1007/s00604-020-04327-2] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2020] [Accepted: 05/15/2020] [Indexed: 12/01/2022]
Abstract
Fully porous silica microspheres (FPSM) with high specific surface area and hierarchical pore as matrix for HPLC were prepared. First, the porous silica nanospheres with controllable particle size and pore diameter were successfully synthesized using a dual-templating approach, the pore size of nanospheres can be increased to 18.4 nm by changing the molar ratios of octyltrimethylammonium bromide (TOMAB) and cetyltrimethyl ammonium bromide (CTAB), which is suitable for separation and analysis of biomolecules without pore enlargement. Then, the micron FPSM with hierarchical pore were synthesized by polymerization-induced colloid aggregation (PICA) using the porous nanospheres as a silicon source, which has a large mesoporous structure (35.2 nm) and high specific surface area (560 m2 g-1). Subsequently, the FPSM modified with octadecyltrichlorosilane were studied as stationary phase for separation of cytochrome C, lysozyme, ribonuclease A, and ovalbumin, bovine serum albumin, and the baseline separation of five proteins was achieved within 1 min. The prepared column was also applied to the fast separation of digests of ovalbumin, and more chromatographic peaks were obtained compared to a commercial column under the same gradient elution conditions. In addition, the static-binding capacity of the functionalized FPSM for bovine serum albumin (BSA) was measured to be 276 mg g-1, which was nearly twice the static adsorption given in literature. Therefore, these FPSM with high specific surface area and hierarchical pore structure are expected to have great potential for the separation of complex biological samples using HPLC. Graphical abstract A synthetic strategy was provided towards FPSM with hierarchical pores and high specific surface area using porous nanospheres as silicon source. The outstanding performance of the FPSM is that it has a high specific surface area while maintaining a large mesoporous size, which overcomes the disadvantage of sacrificing the specific surface area when increasing the pore size of porous silica microspheres prepared by using the traditional PICA method.
Collapse
Affiliation(s)
- Hongjun Xia
- Henan Key Laboratory of Rare Earth Functional Materials, The Key Laboratory of Rare Earth Functional Materials and Applications, Zhoukou Normal University, Zhoukou, 466001, People's Republic of China.,Key Laboratory of Synthetic and Natural Functional Molecule Chemistry of Ministry of Education, Institute of Modern Separation Science, Key Lab of Modern Separation Science in Shaanxi Province, Northwest University, Xi'an, 710069, China
| | - Lin Wang
- Henan Key Laboratory of Rare Earth Functional Materials, The Key Laboratory of Rare Earth Functional Materials and Applications, Zhoukou Normal University, Zhoukou, 466001, People's Republic of China
| | - Chunyang Li
- Henan Key Laboratory of Rare Earth Functional Materials, The Key Laboratory of Rare Earth Functional Materials and Applications, Zhoukou Normal University, Zhoukou, 466001, People's Republic of China
| | - Boshi Tian
- Henan Key Laboratory of Rare Earth Functional Materials, The Key Laboratory of Rare Earth Functional Materials and Applications, Zhoukou Normal University, Zhoukou, 466001, People's Republic of China
| | - Qingfeng Li
- Henan Key Laboratory of Rare Earth Functional Materials, The Key Laboratory of Rare Earth Functional Materials and Applications, Zhoukou Normal University, Zhoukou, 466001, People's Republic of China
| | - Hui Zhao
- Henan Key Laboratory of Rare Earth Functional Materials, The Key Laboratory of Rare Earth Functional Materials and Applications, Zhoukou Normal University, Zhoukou, 466001, People's Republic of China.
| | - Quan Bai
- Key Laboratory of Synthetic and Natural Functional Molecule Chemistry of Ministry of Education, Institute of Modern Separation Science, Key Lab of Modern Separation Science in Shaanxi Province, Northwest University, Xi'an, 710069, China.
| |
Collapse
|
15
|
Development and Optimization of a Reversed-Phase HPLC Method to Separate Pulse Proteins. FOOD ANAL METHOD 2020. [DOI: 10.1007/s12161-020-01771-x] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
|
16
|
Abstract
Continued improvements in HPLC have led to faster and more efficient separations than previously possible. One important aspect of these improvements has been the increase in instrument operating pressure and the advent of ultrahigh pressure LC (UHPLC). Commercial instrumentation is now capable of up to ~20 kpsi, allowing fast and efficient separations with 5-15 cm columns packed with sub-2 μm particles. Home-built instruments have demonstrated the benefits of even further increases in instrument pressure. The focus of this review is on recent advancements and applications in liquid chromatography above 20 kpsi. We outline the theory and advantages of higher pressure and discuss instrument hardware and design capable of withstanding 20 kpsi or greater. We also overview column packing procedures and stationary phase considerations for HPLC above 20 kpsi, and lastly highlight a few recent applicatioob pressure instruments for the analysis of complex mixtures.
Collapse
Affiliation(s)
- Matthew J Sorensen
- Department of Chemistry, University of Michigan, Ann Arbor, MI, 48109, USA
| | - Brady G Anderson
- Department of Chemistry, University of Michigan, Ann Arbor, MI, 48109, USA
| | - Robert T Kennedy
- Department of Chemistry, University of Michigan, Ann Arbor, MI, 48109, USA.,Department of Pharmacology, University of Michigan, Ann Arbor, MI, 48109, USA
| |
Collapse
|
17
|
Kang L, Weng N, Jian W. LC–MS bioanalysis of intact proteins and peptides. Biomed Chromatogr 2019; 34:e4633. [DOI: 10.1002/bmc.4633] [Citation(s) in RCA: 33] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2019] [Revised: 06/19/2019] [Accepted: 06/25/2019] [Indexed: 01/02/2023]
Affiliation(s)
- Lijuan Kang
- Drug Metabolism and Pharmacokinetics (DMPK)Janssen Pharmaceutical Companies of Johnson and Johnson Spring House PA
| | - Naidong Weng
- Drug Metabolism and Pharmacokinetics (DMPK)Janssen Pharmaceutical Companies of Johnson and Johnson Spring House PA
| | - Wenying Jian
- Drug Metabolism and Pharmacokinetics (DMPK)Janssen Pharmaceutical Companies of Johnson and Johnson Spring House PA
| |
Collapse
|
18
|
Wang Y, Olesik SV. Enhanced-Fluidity Liquid Chromatography-Mass Spectrometry for Intact Protein Separation and Characterization. Anal Chem 2018; 91:935-942. [PMID: 30523683 DOI: 10.1021/acs.analchem.8b03970] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
Recent advances in the analysis of proteins have increased the demand for more efficient techniques to separate intact proteins. Enhanced-fluidity liquid chromatography (EFLC) involves the addition of liquefied CO2 to conventional liquid mobile phases. The addition of liquefied CO2 increases diffusivity and decreases viscosity, which inherently leads to a more efficient separation. Herein, EFLC is applied to hydrophobic interaction chromatography (HIC) stationary phases for the first time to study the impact of liquefied CO2 to the chromatographic behavior of proteins. The effects of liquefied CO2 on chromatographic properties, charge state distributions (CSDs), and ionization efficiencies were evaluated. EFLC offered improved chromatographic performance compared to conventional liquid chromatography (LC) methods including a shorter analysis time, better peak shapes, and higher plate numbers. The addition of liquefied CO2 to the mobile phase provided an electrospray ionization (ESI)-friendly and "supercharging" reagent without sacrificing chromatographic performance, which can be used to improve peptide and protein identification in large-scale application.
Collapse
Affiliation(s)
- Yanhui Wang
- Department of Chemistry and Biochemistry , The Ohio State University , 100 West 18th Avenue , Columbus , Ohio 43210 , United States of America
| | - Susan V Olesik
- Department of Chemistry and Biochemistry , The Ohio State University , 100 West 18th Avenue , Columbus , Ohio 43210 , United States of America
| |
Collapse
|
19
|
Haghighi F, Talebpour Z, Nezhad AS. Towards fully integrated liquid chromatography on a chip: Evolution and evaluation. Trends Analyt Chem 2018. [DOI: 10.1016/j.trac.2018.05.002] [Citation(s) in RCA: 33] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
|
20
|
Fulton KM, Li J, Tomas JM, Smith JC, Twine SM. Characterizing bacterial glycoproteins with LC-MS. Expert Rev Proteomics 2018; 15:203-216. [PMID: 29400572 DOI: 10.1080/14789450.2018.1435276] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
Abstract
INTRODUCTION Though eukaryotic glycoproteins have been studied since their discovery in the 1930s, the first bacterial glycoprotein was not identified until the 1970s. As a result, their role in bacterial pathogenesis is still not well understood and they remain an understudied component of bacterial virulence. In recent years, mass spectrometry has emerged as a leading technology for the study of bacterial glycoproteins, largely due to its sensitivity and versatility. Areas covered: Identification and comprehensive characterization of bacterial glycoproteins usually requires multiple complementary mass spectrometry approaches, including intact protein analysis, top-down analysis, and bottom-up methods used in combination with specialized liquid chromatography. This review provides an overview of liquid chromatography separation technologies, as well as current and emerging mass spectrometry approaches used specifically for bacterial glycoprotein identification and characterization. Expert commentary: Bacterial glycoproteins may have significant clinical utility as a result of their unique structures and exposure on the surface of the cells. Better understanding of these glycoconjugates is an essential first step towards that goal. These often unique structures, and by extension the key enzymes involved in their synthesis, represent promising targets for novel antimicrobials, while unique carbohydrate structures may be used as antigens in vaccines or as biomarkers.
Collapse
Affiliation(s)
- Kelly M Fulton
- a Human Health Therapeutics Portfolio , National Research Council Canada , Ottawa , Canada
| | - Jianjun Li
- a Human Health Therapeutics Portfolio , National Research Council Canada , Ottawa , Canada
| | - Juan M Tomas
- b Departament de Microbiologia, Facultat de Biologia , Universitat de Barcelona , Barcelona , Spain
| | - Jeffrey C Smith
- c Department of Chemistry , Carleton University , Ottawa , Canada
| | - Susan M Twine
- a Human Health Therapeutics Portfolio , National Research Council Canada , Ottawa , Canada
| |
Collapse
|
21
|
Blue LE, Franklin EG, Godinho JM, Grinias JP, Grinias KM, Lunn DB, Moore SM. Recent advances in capillary ultrahigh pressure liquid chromatography. J Chromatogr A 2017; 1523:17-39. [PMID: 28599863 DOI: 10.1016/j.chroma.2017.05.039] [Citation(s) in RCA: 47] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2017] [Revised: 05/12/2017] [Accepted: 05/15/2017] [Indexed: 11/28/2022]
Abstract
In the twenty years since its initial demonstration, capillary ultrahigh pressure liquid chromatography (UHPLC) has proven to be one of most powerful separation techniques for the analysis of complex mixtures. This review focuses on the most recent advances made since 2010 towards increasing the performance of such separations. Improvements in capillary column preparation techniques that have led to columns with unprecedented performance are described. New stationary phases and phase supports that have been reported over the past decade are detailed, with a focus on their use in capillary formats. A discussion on the instrument developments that have been required to ensure that extra-column effects do not diminish the intrinsic efficiency of these columns during analysis is also included. Finally, the impact of these capillary UHPLC topics on the field of proteomics and ways in which capillary UHPLC may continue to be applied to the separation of complex samples are addressed.
Collapse
Affiliation(s)
- Laura E Blue
- Process Development, Amgen Inc., Thousand Oaks, CA 91320, USA
| | - Edward G Franklin
- HPLC Research & Development, Restek Corp., Bellefonte, PA 16823, USA
| | - Justin M Godinho
- Department of Chemistry, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599, USA
| | - James P Grinias
- Department of Chemistry and Biochemistry, Rowan University, Glassboro, NJ 08028, USA.
| | - Kaitlin M Grinias
- Department of Product Development & Supply, GlaxoSmithKline, King of Prussia, PA 19406, USA
| | - Daniel B Lunn
- Department of Chemistry, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599, USA
| | | |
Collapse
|
22
|
Xia H, Wan G, Zhao J, Liu J, Bai Q. Preparation and characterization of monodisperse large-porous silica microspheres as the matrix for protein separation. J Chromatogr A 2016; 1471:138-144. [DOI: 10.1016/j.chroma.2016.10.025] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2016] [Revised: 10/02/2016] [Accepted: 10/11/2016] [Indexed: 12/13/2022]
|
23
|
De Pauw R, Swier T, Degreef B, Desmet G, Broeckhoven K. On the feasibility to conduct gradient liquid chromatography separations in narrow-bore columns at pressures up to 2000 bar. J Chromatogr A 2016; 1473:48-55. [DOI: 10.1016/j.chroma.2016.10.008] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2016] [Revised: 10/03/2016] [Accepted: 10/06/2016] [Indexed: 11/28/2022]
|
24
|
Development of a 45kpsi ultrahigh pressure liquid chromatography instrument for gradient separations of peptides using long microcapillary columns and sub-2μm particles. J Chromatogr A 2016; 1469:60-67. [PMID: 27702615 DOI: 10.1016/j.chroma.2016.09.053] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2016] [Revised: 09/22/2016] [Accepted: 09/23/2016] [Indexed: 11/22/2022]
Abstract
Commercial chromatographic instrumentation for bottom-up proteomics is often inadequate to resolve the number of peptides in many samples. This has inspired a number of complex approaches to increase peak capacity, including various multidimensional approaches, and reliance on advancements in mass spectrometry. One-dimensional reversed phase separations are limited by the pressure capabilities of commercial instruments and prevent the realization of greater separation power in terms of speed and resolution inherent to smaller sorbents and ultrahigh pressure liquid chromatography. Many applications with complex samples could benefit from the increased separation performance of long capillary columns packed with sub-2μm sorbents. Here, we introduce a system that operates at a constant pressure and is capable of separations at pressures up to 45kpsi. The system consists of a commercially available capillary liquid chromatography instrument, for sample management and gradient creation, and is modified with a storage loop and isolated pneumatic amplifier pump for elevated separation pressure. The system's performance is assessed with a complex peptide mixture and a range of microcapillary columns packed with sub-2μm C18 particles.
Collapse
|
25
|
Astefanei A, Dapic I, Camenzuli M. Different Stationary Phase Selectivities and Morphologies for Intact Protein Separations. Chromatographia 2016; 80:665-687. [PMID: 28529348 PMCID: PMC5413533 DOI: 10.1007/s10337-016-3168-z] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2016] [Revised: 08/17/2016] [Accepted: 09/06/2016] [Indexed: 12/18/2022]
Abstract
The central dogma of biology proposed that one gene encodes for one protein. We now know that this does not reflect reality. The human body has approximately 20,000 protein-encoding genes; each of these genes can encode more than one protein. Proteins expressed from a single gene can vary in terms of their post-translational modifications, which often regulate their function within the body. Understanding the proteins within our bodies is a key step in understanding the cause, and perhaps the solution, to disease. This is one of the application areas of proteomics, which is defined as the study of all proteins expressed within an organism at a given point in time. The human proteome is incredibly complex. The complexity of biological samples requires a combination of technologies to achieve high resolution and high sensitivity analysis. Despite the significant advances in mass spectrometry, separation techniques are still essential in this field. Liquid chromatography is an indispensable tool by which low-abundant proteins in complex samples can be enriched and separated. However, advances in chromatography are not as readily adapted in proteomics compared to advances in mass spectrometry. Biologists in this field still favour reversed-phase chromatography with fully porous particles. The purpose of this review is to highlight alternative selectivities and stationary phase morphologies that show potential for application in top-down proteomics; the study of intact proteins.
Collapse
Affiliation(s)
- A. Astefanei
- Centre for Analytical Science in Amsterdam (CASA), Van’t Hoff Institute for Molecular Sciences, University of Amsterdam, Science Park 904, 1098 XH Amsterdam, The Netherlands
| | - I. Dapic
- Centre for Analytical Science in Amsterdam (CASA), Van’t Hoff Institute for Molecular Sciences, University of Amsterdam, Science Park 904, 1098 XH Amsterdam, The Netherlands
| | - M. Camenzuli
- Centre for Analytical Science in Amsterdam (CASA), Van’t Hoff Institute for Molecular Sciences, University of Amsterdam, Science Park 904, 1098 XH Amsterdam, The Netherlands
| |
Collapse
|
26
|
Calderón-Celis F, Diez-Fernández S, Costa-Fernández JM, Encinar JR, Calvete JJ, Sanz-Medel A. Elemental Mass Spectrometry for Absolute Intact Protein Quantification without Protein-Specific Standards: Application to Snake Venomics. Anal Chem 2016; 88:9699-9706. [PMID: 27593495 DOI: 10.1021/acs.analchem.6b02585] [Citation(s) in RCA: 42] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Abstract
Absolute protein quantification methods based on molecular mass spectrometry usually require stable isotope-labeled analogous standards for each target protein or peptide under study, which in turn must be certified using natural standards. In this work, we report a direct and accurate methodology based on capLC-ICP-QQQ and online isotope dilution analysis for the absolute and sensitive quantification of intact proteins. The combination of the postcolumn addition of 34S and a generic S-containing internal standard spiked to the sample provides full compound independent detector response and thus protein quantification without the need for specific standards. Quantitative recoveries, using a chromatographic core-shell C4 column for the various protein species assayed were obtained (96-100%). Thus, the proposed strategy enables the accurate quantification of proteins even if no specific standards are available for them. In addition, to the best of our knowledge, we obtained the lowest detection limits reported in the quantitative analysis of intact proteins by direct measurement of sulfur with ICPMS (358 fmol) and protein (ranging from 7 to 15 fmol depending on the assayed protein). The quantitative results for individual and simple mixtures of model proteins were statistically indistinguishable from the manufacturer's values. Finally, the suitability of the strategy for real sample analysis (including quantitative protein recovery from the column) was illustrated for the individual absolute quantification of the proteins and whole protein content in a venom sample. Parallel capLC-ESI-QTOF analysis was employed to identify the proteins, a prerequisite to translate the mass of quantified S for each chromatographic peak into individual protein mass.
Collapse
Affiliation(s)
- Francisco Calderón-Celis
- Department of Physical and Analytical Chemistry, University of Oviedo , Julián Clavería 8, 33006 Oviedo, Spain
| | - Silvia Diez-Fernández
- Department of Physical and Analytical Chemistry, University of Oviedo , Julián Clavería 8, 33006 Oviedo, Spain
| | - José Manuel Costa-Fernández
- Department of Physical and Analytical Chemistry, University of Oviedo , Julián Clavería 8, 33006 Oviedo, Spain
| | - Jorge Ruiz Encinar
- Department of Physical and Analytical Chemistry, University of Oviedo , Julián Clavería 8, 33006 Oviedo, Spain
| | - Juan J Calvete
- Instituto de Biomedicina de Valencia , Consejo Superior de Investigaciones Científicas (CSIC), Jaume Roig 11, 46010 Valencia, Spain
| | - Alfredo Sanz-Medel
- Department of Physical and Analytical Chemistry, University of Oviedo , Julián Clavería 8, 33006 Oviedo, Spain
| |
Collapse
|
27
|
Hara T, Eeltink S, Desmet G. Exploring the pressure resistance limits of monolithic silica capillary columns. J Chromatogr A 2016; 1446:164-9. [PMID: 27086284 DOI: 10.1016/j.chroma.2016.04.010] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2016] [Revised: 04/01/2016] [Accepted: 04/04/2016] [Indexed: 11/18/2022]
Abstract
We report on an experimental approach to measure the pressure stability and mechanical strength of monolithic silica capillary columns with different diameters (50 and 100μm i.d.) and considering two different domain sizes, typical for the second generation monoliths or smaller. The approach consists of exposing the capillaries to ultra-high pressures (gradually stepwise increased from 20 to 80MPa), with intermediate measurements of the column efficiency, permeability and retention factors to check the mechanical stability of the bed. It was observed that all tested columns withstood the imposed pressure stress, i.e., all the tested parameters remained unaffected up till the maximal test pressure of 80MPa. The applied pressure gradient corresponded to 320MPa/m. The two 100μm i.d.-capillary columns were also exposed to pressures between 80 and 90MPa for a prolonged time (8h), and this did not cause any damage either.
Collapse
Affiliation(s)
- Takeshi Hara
- Vrije Universiteit Brussel, Department of Chemical Engineering, Pleinlaan 2, B-1050 Brussels, Belgium
| | - Sebastiaan Eeltink
- Vrije Universiteit Brussel, Department of Chemical Engineering, Pleinlaan 2, B-1050 Brussels, Belgium
| | - Gert Desmet
- Vrije Universiteit Brussel, Department of Chemical Engineering, Pleinlaan 2, B-1050 Brussels, Belgium.
| |
Collapse
|
28
|
Chen B, Peng Y, Valeja SG, Xiu L, Alpert AJ, Ge Y. Online Hydrophobic Interaction Chromatography-Mass Spectrometry for Top-Down Proteomics. Anal Chem 2016; 88:1885-91. [PMID: 26729044 DOI: 10.1021/acs.analchem.5b04285] [Citation(s) in RCA: 72] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
Recent progress in top-down proteomics has led to a demand for mass spectrometry (MS)-compatible chromatography techniques to separate intact proteins using volatile mobile phases. Conventional hydrophobic interaction chromatography (HIC) provides high-resolution separation of proteins under nondenaturing conditions but requires high concentrations of nonvolatile salts. Herein, we introduce a series of more-hydrophobic HIC materials that can retain proteins using MS-compatible concentrations of ammonium acetate. The new HIC materials appear to function as a hybrid form of conventional HIC and reverse phase chromatography. The function of the salt seems to be preserving protein structure rather than promoting retention. Online HIC-MS is feasible for both qualitative and quantitative analysis. This is demonstrated with standard proteins and a complex cell lysate. The mass spectra of proteins from the online HIC-MS exhibit low charge-state distributions, consistent with those commonly observed in native MS. Furthermore, HIC-MS can chromatographically separate proteoforms differing by minor modifications. Hence, this new HIC-MS combination is promising for top-down proteomics.
Collapse
Affiliation(s)
- Bifan Chen
- Department of Chemistry, University of Wisconsin-Madison , Madison, Wisconsin, United States
| | - Ying Peng
- Department of Cell and Regenerative Biology, University of Wisconsin-Madison , Madison, Wisconsin, United States
| | - Santosh G Valeja
- Department of Cell and Regenerative Biology, University of Wisconsin-Madison , Madison, Wisconsin, United States
| | - Lichen Xiu
- Department of Chemistry, University of Wisconsin-Madison , Madison, Wisconsin, United States
| | - Andrew J Alpert
- Department of Cell and Regenerative Biology, University of Wisconsin-Madison , Madison, Wisconsin, United States.,PolyLC, Inc., 9151 Rumsey Rd., Suite 180, Columbia, Maryland, United States
| | - Ying Ge
- Department of Chemistry, University of Wisconsin-Madison , Madison, Wisconsin, United States.,Department of Cell and Regenerative Biology, University of Wisconsin-Madison , Madison, Wisconsin, United States.,Human Proteomics Program, School of Medicine and Public Health, University of Wisconsin-Madison , Madison, Wisconsin, United States
| |
Collapse
|
29
|
Nazario CED, Silva MR, Franco MS, Lanças FM. Evolution in miniaturized column liquid chromatography instrumentation and applications: An overview. J Chromatogr A 2015; 1421:18-37. [PMID: 26381569 DOI: 10.1016/j.chroma.2015.08.051] [Citation(s) in RCA: 77] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2015] [Revised: 08/24/2015] [Accepted: 08/25/2015] [Indexed: 02/01/2023]
Abstract
The purpose of this article is to underline the miniaturized LC instrumental system and describe the evolution of commercially available systems by discussing their advantages and drawbacks. Nowadays, there are already many miniaturized LC systems available with a great variety of pump design, interface and detectors as well as efficient columns technologies and reduced connections devices. The solvent delivery systems are able to drive the mobile phase without flow splitters and promote gradient elution using either dual piston reciprocating or syringe-type pumps. The mass spectrometry as detection system is the most widely used detection system; among many alternative ionization sources direct-EI LC-MS is a promising alternative to APCI. In addition, capillary columns are now available showing many possibilities of stationary phases, inner diameters and hardware materials. This review provides a discussion about miniaturized LC demonstrating fundamentals and instrumentals' aspects of the commercially available miniaturized LC instrumental system mainly nano and micro LC formats. This review also covers the recent developments and trends in instrumentation, capillary and nano columns, and several applications of this very important and promising field.
Collapse
Affiliation(s)
| | - Meire R Silva
- Institute of Chemistry of Sao Carlos, University of Sao Paulo, Sao Carlos, SP, Brazil
| | - Maraíssa S Franco
- Institute of Chemistry of Sao Carlos, University of Sao Paulo, Sao Carlos, SP, Brazil
| | - Fernando M Lanças
- Institute of Chemistry of Sao Carlos, University of Sao Paulo, Sao Carlos, SP, Brazil.
| |
Collapse
|
30
|
Liu H, Jeong J, Kao YH, Zhang YT. Characterization of free thiol variants of an IgG1 by reversed phase ultra high pressure liquid chromatography coupled with mass spectrometry. J Pharm Biomed Anal 2015; 109:142-9. [DOI: 10.1016/j.jpba.2015.02.015] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2014] [Revised: 02/05/2015] [Accepted: 02/08/2015] [Indexed: 11/26/2022]
|
31
|
Bobály B, Mikola V, Sipkó E, Márta Z, Fekete J. Recovery of Proteins Affected by Mobile Phase Trifluoroacetic Acid Concentration in Reversed-Phase Chromatography. J Chromatogr Sci 2014; 53:1078-83. [PMID: 25501119 DOI: 10.1093/chromsci/bmu169] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2014] [Indexed: 12/29/2022]
Abstract
It was found that recoveries of proteins depend on trifluoroacetic acid concentration in the mobile phase and showed maximum in the range of 0.01-0.1 v/v%. Transferrin and lysozyme were used to evaluate the recoveries of proteins from dedicated reversed-phase columns. Different types of reversed-phase columns were evaluated, such as core shell type materials (Aeris Widepore with C4, C8 and C18 modification) as well as fully porous hybrid particles (Waters BEH, modified with C4 and C18 alkyl chains). Recoveries ranged between 60.7-95.2% for transferrin and 72.1-99.8% for lysozyme. Based on the data presented, at least two different adsorption effects, the well-known hydrophobic and silanophilic/polar interaction might influence the recovery. In addition to this, conformational effects due to ion pairing with the acidic mobile phase additive might change them.
Collapse
Affiliation(s)
- Balázs Bobály
- Department of Inorganic and Analytical Chemistry, Budapest University of Technology and Economics, Szt. Gellért tér 4, Budapest 1111, Hungary
| | - Vivien Mikola
- Department of Inorganic and Analytical Chemistry, Budapest University of Technology and Economics, Szt. Gellért tér 4, Budapest 1111, Hungary
| | - Enikő Sipkó
- Department of Inorganic and Analytical Chemistry, Budapest University of Technology and Economics, Szt. Gellért tér 4, Budapest 1111, Hungary
| | - Zoltán Márta
- Department of Inorganic and Analytical Chemistry, Budapest University of Technology and Economics, Szt. Gellért tér 4, Budapest 1111, Hungary
| | - Jenő Fekete
- Department of Inorganic and Analytical Chemistry, Budapest University of Technology and Economics, Szt. Gellért tér 4, Budapest 1111, Hungary
| |
Collapse
|
32
|
Maes K, Smolders I, Michotte Y, Van Eeckhaut A. Strategies to reduce aspecific adsorption of peptides and proteins in liquid chromatography-mass spectrometry based bioanalyses: an overview. J Chromatogr A 2014; 1358:1-13. [PMID: 25022477 DOI: 10.1016/j.chroma.2014.06.072] [Citation(s) in RCA: 64] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2014] [Revised: 06/11/2014] [Accepted: 06/22/2014] [Indexed: 12/20/2022]
Abstract
In the drug-discovery setting, the development of new peptide and protein-based biopharmaceuticals attracts increased attention from the pharmaceutical industry and consequently demands the development of high-throughput LC-MS methods. Regulatory guidelines require bioanalytical methods to be validated not only in terms of linearity, sensitivity, accuracy, precision, selectivity and stability, but also in terms of carryover. Carryover results from the aspecific adsorption of analyte(s) to parts of the analytical system and thus introduces bias in both identification and quantification assays. Moreover, nonspecific binding occurs at the surface of materials used during sample preparation, such as pipette tips, sample tubes and LC-vials. Hence, linearity, sensitivity and repeatability of the analyses are negatively affected. Due to the great diversity in physicochemical properties of biomolecules, there is no general approach available to minimize adsorption phenomena. Therefore, we aim to present different strategies which can be generically applied to reduce nonspecific binding of peptides and proteins. In the first part of this review, a systematic approach is proposed to guide the reader through the different solvents which can be used to dissolve the analyte of interest. Indeed, proper solubilization is one of the most important factors for a successful analysis. In addition, alternative approaches are described to improve analyte recovery from the sample vial. The second part focuses on strategies to efficiently reduce adsorption at components of the autosampler, column and mass spectrometer. Thereby carryover is reduced while maintaining a sufficiently wide dynamic range of the assay.
Collapse
Affiliation(s)
- Katrien Maes
- Department of Pharmaceutical Chemistry and Drug Analysis, Center for Neurosciences (C4N), Vrije Universiteit Brussel, Laarbeeklaan 103, 1090 Brussels, Belgium
| | - Ilse Smolders
- Department of Pharmaceutical Chemistry and Drug Analysis, Center for Neurosciences (C4N), Vrije Universiteit Brussel, Laarbeeklaan 103, 1090 Brussels, Belgium
| | - Yvette Michotte
- Department of Pharmaceutical Chemistry and Drug Analysis, Center for Neurosciences (C4N), Vrije Universiteit Brussel, Laarbeeklaan 103, 1090 Brussels, Belgium
| | - Ann Van Eeckhaut
- Department of Pharmaceutical Chemistry and Drug Analysis, Center for Neurosciences (C4N), Vrije Universiteit Brussel, Laarbeeklaan 103, 1090 Brussels, Belgium.
| |
Collapse
|
33
|
Zhou L, Danielson ND. The ionic liquid isopropylammonium formate as a mobile phase modifier to improve protein stability during reversed phase liquid chromatography. J Chromatogr B Analyt Technol Biomed Life Sci 2013; 940:112-20. [PMID: 24141045 PMCID: PMC4209125 DOI: 10.1016/j.jchromb.2013.08.005] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2013] [Revised: 07/31/2013] [Accepted: 08/01/2013] [Indexed: 10/26/2022]
Abstract
The room temperature ionic liquid isopropylammonium formate (IPAF) is studied as a reversed phase HPLC mobile phase modifier for separation of native proteins using a polymeric column and the protein stability is compared to that using acetonitrile (MeCN) as the standard organic mobile phase modifier. A variety of important proteins with different numbers of subunits are investigated, including non-subunit proteins: albumin, and amyloglucosidase (AMY); a two subunit protein: thyroglobulin (THY); and four subunit proteins: glutamate dehydrogenase (GDH) and lactate dehydrogenase (LDH). A significant enhancement in protein stability is observed in the chromatograms upon using IPAF as a mobile phase modifier. The first sharper peak at about 2min represented protein in primarily the native form and a second broader peak more retained at about 5-6min represented substantially denatured or possibly aggregated protein. The investigated proteins (except LDH) could maintain the native form within up to 50% IPAF, while a mobile phase, with as low as 10% MeCN, induced protein denaturation. The assay for pyruvate using LDH has further shown that enzymatic activity can be maintained up to 30% IPAF in water in contrast to no activity using 30% MeCN.
Collapse
Affiliation(s)
- Ling Zhou
- Department of Chemistry and Biochemistry, Miami University, Oxford, OH 45056, United States.
| | | |
Collapse
|
34
|
Abstract
There is increasing interest within the pharmaceutical industry in the development of proteins and peptides as drugs in addition to their use as biomarkers. Immunochemistry-based techniques have been traditionally used for the quantitation of proteins and peptides; however, LC-MS-based methodologies are being increasingly adopted as they offer several advantages. UHPLC is well established within the small-molecule community as a means to increase resolution and/or the speed of separations prior to MS detection; however, it is rarely applied to proteins or peptides separations. In this paper, current applications of UHPLC to such separations are reviewed, as well as considerations with regard to the effect of altering various chromatographic parameters.
Collapse
|
35
|
Rogers BJ, Birdsall RE, Wu Z, Wirth MJ. RPLC of intact proteins using sub-0.5 μm particles and commercial instrumentation. Anal Chem 2013; 85:6820-5. [PMID: 23819838 DOI: 10.1021/ac400982w] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
This paper addresses whether one can gain an improvement in speed or resolution with a silica colloidal crystal (SCC) of nonporous 470 nm particles when using a commercial nano-UHPLC. Compared to a capillary packed with nonporous 1.3 μm particles and the same C4 bonded phase, the peak width for BSA is decreased by a factor of 6.8 for the SCC. Some of this improvement is attributable to slip flow since the ratio of particle diameters is only 2.8. Resolution in protein separations was compared for a 2-cm capillary of SCC vs a 5-cm column of porous 1.7 μm particles. Both used a C4 bonded phase, and on-column fluorescence detection was used for the SCC. Split flow (5:1) before the SCC decreased the gradient delay time to 0.4 min and the injected volume to 0.4 nL. For variants from the labeling of BSA, the SCC had a 5-fold higher speed and 2-fold higher resolution than did the commercial column. For a monoclonal antibody and its aggregates, the SCC had a 3-fold higher speed and a 3-fold higher resolution compared to the commercial column. The SCC gave baseline resolution of the monomer, dimer and trimer in 5 min. The results show that a significant advantage can be gained using a commercial instrument with the SCC, despite the instrument not being designed for use with such small particles.
Collapse
Affiliation(s)
- Benjamin J Rogers
- Department of Chemistry, Purdue University, West Lafayette, Indiana 47907, United States
| | | | | | | |
Collapse
|
36
|
Rigobello-Masini M, Penteado JCP, Masini JC. Monolithic columns in plant proteomics and metabolomics. Anal Bioanal Chem 2012; 405:2107-22. [DOI: 10.1007/s00216-012-6574-6] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2012] [Revised: 11/02/2012] [Accepted: 11/13/2012] [Indexed: 12/16/2022]
|
37
|
Szalka M, Kostka J, Rokaszewski E, Kaczmarski K. Analysis of related substances in bisoprolol fumarate on sub-2-μm adsorbents. ACTA CHROMATOGR 2012. [DOI: 10.1556/achrom.24.2012.2.2] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|
38
|
Perfusion reversed-phase high-performance liquid chromatography for protein separation from detergent-containing solutions: An alternative to gel-based approaches. Anal Biochem 2012; 424:97-107. [DOI: 10.1016/j.ab.2012.02.021] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2011] [Revised: 02/15/2012] [Accepted: 02/16/2012] [Indexed: 11/19/2022]
|
39
|
Siviero A, Bergna M, Famiglini G, Mantegazza A, Palma P, Cappiello A. In-depth performance investigation of a nano-LC gradient generator. Electrophoresis 2012; 33:575-82. [DOI: 10.1002/elps.201100331] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
|
40
|
Chen CJ, Chen WY, Tseng MC, Chen YR. Tunnel frit: a nonmetallic in-capillary frit for nanoflow ultra high-performance liquid chromatography-mass spectrometryapplications. Anal Chem 2011; 84:297-303. [PMID: 22097963 DOI: 10.1021/ac202549y] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
In this study, an easy method to fabricate a durable in-capillary frit was developed for use in nanoflow liquid chromatography (nanoLC). A small orifice was tunneled into the sol-gel frit during the polymerization process resulting in the simple fabrication of a tunnel frit. A short packing tunnel frit column (2 cm, C(18) particles) was able to sustain over 10,000 psi continuous liquid flow for 10 days without observation of particle loss, and back pressure variation was less than 5%. The tunnel frit was successfully applied to the fabrication of nanoflow ultra high-performance liquid chromatography (nano-UHPLC) trap and analytical columns. In the analysis of tryptic peptides, the tunnel frit trap and analytical columns were demonstrated to have high separation efficiency and sensitivity. In analysis of phosphopeptides, the use of the nonmetallic tunnel frit column showed better sensitivity than the metallic frit column. This design can facilitate the preparation of nano-HPLC and nano-UHPLC columns and the packing material can easily be refilled when the column is severely contaminated or clogged.
Collapse
Affiliation(s)
- Chao-Jung Chen
- Proteomics Core Laboratory, Department of Medical Research, China Medical University Hospital, Taichung 404, Taiwan
| | | | | | | |
Collapse
|
41
|
High-resolution separations of protein isoforms with liquid chromatography time-of-flight mass spectrometry using polymer monolithic capillary columns. J Chromatogr A 2011; 1218:5504-11. [DOI: 10.1016/j.chroma.2011.06.049] [Citation(s) in RCA: 38] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2011] [Revised: 05/16/2011] [Accepted: 06/10/2011] [Indexed: 11/22/2022]
|
42
|
Nutriproteomics: technologies and applications for identification and quantification of biomarkers and ingredients. Proc Nutr Soc 2011; 70:351-64. [DOI: 10.1017/s0029665111000528] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Abstract
Nutrition refers to the process by which a living organism ingests and digests food and uses the nutrients therein for growth, tissue maintenance and all other functions essential to life. Food components interact with our body at molecular, cellular, organ and system level. Nutrients come in complex mixtures, in which the presence and concentration of single compounds as well as their interactions with other compounds and the food matrix influence their bioavailability and bioefficacy. Traditionally, nutrition research mainly concentrated on supplying nutrients of quality to nourish populations and on preventing specific nutrient deficiencies. More recently, it investigates health-related aspects of individual ingredients or of complete diets, in view of health promotion, performance optimisation, disease prevention and risk assessment. This review focuses on proteins and peptides, their role as nutrients and biomarkers and on the technologies developed for their analysis. In the first part of this review, we provide insights into the way proteins are currently characterised and analysed using classical and emerging proteomic approaches. The scope of the second part is to review major applications of proteomics to nutrition, from characterisation of food proteins and peptides, via investigation of health-related food benefits to understanding disease-related mechanisms.
Collapse
|
43
|
Capriotti AL, Cavaliere C, Foglia P, Samperi R, Laganà A. Intact protein separation by chromatographic and/or electrophoretic techniques for top-down proteomics. J Chromatogr A 2011; 1218:8760-76. [PMID: 21689823 DOI: 10.1016/j.chroma.2011.05.094] [Citation(s) in RCA: 68] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2011] [Revised: 04/13/2011] [Accepted: 05/28/2011] [Indexed: 12/26/2022]
Abstract
Mass spectrometry used in combination with a wide variety of separation methods is the principal methodology for proteomics. In bottom-up approach, proteins are cleaved with a specific proteolytic enzyme, followed by peptide separation and MS identification. In top-down approach intact proteins are introduced into the mass spectrometer. The ions generated by electrospray ionization are then subjected to gas-phase separation, fragmentation, fragment separation, and automated interpretation of mass spectrometric and chromatographic data yielding both the molecular weight of the intact protein and the protein fragmentation pattern. This approach requires high accuracy mass measurement analysers capable of separating the multi-charged isotopic cluster of proteins, such as hybrid ion trap-Fourier transform instruments (LTQ-FTICR, LTQ-Orbitrap). Front-end separation technologies tailored for proteins are of primary importance to implement top-down proteomics. This review intends to provide the state of art of protein chromatographic and electrophoretic separation methods suitable for MS coupling, and to illustrate both monodimensional and multidimensional approaches used for LC-MS top-down proteomics. In addition, some recent progresses in protein chromatography that may provide an alternative to those currently employed are also discussed.
Collapse
Affiliation(s)
- Anna Laura Capriotti
- Department of Chemistry, Sapienza Università di Roma, Piazzale Aldo Moro 5, 00185 Rome, Italy
| | | | | | | | | |
Collapse
|
44
|
Patel M, Riley F, Wang J, Lovdahl M, Taylor L. Packed column supercritical fluid chromatography of isomeric polypeptide pairs. J Chromatogr A 2011; 1218:2593-7. [DOI: 10.1016/j.chroma.2011.03.005] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2010] [Revised: 03/01/2011] [Accepted: 03/07/2011] [Indexed: 10/18/2022]
|
45
|
Abstract
The commercialization of ultra-performance liquid chromatography (UPLC) has allowed more researchers to take advantage of the benefits of this work. Many researchers are exploring this technique to reduce analytical throughput and to increase resolution. The majority of this work has focused on small molecule analysis; however, this technique can provide the same advantages for the analysis of proteins. Traditionally, protein chromatography has suffered from a number of issues such as carryover, peak splitting, peak broadening, and poor peak shape. Because UPLC utilizes a smaller particle at a higher pressure and flow rate, many of these issues are remedied. When used in combination with mass spectrometry, UPLC becomes a powerful tool for protein identification, characterization, and quantitation. In this work we show how UPLC/MS can be used to separate and identify intact proteins.
Collapse
Affiliation(s)
- Timothy R Croley
- US Food and Drug Administration Center for Food Safety and Applied Nutrition, 5100 Paint Branch Parkway, College Park, USA
| |
Collapse
|
46
|
Mohr J, Swart R, Samonig M, Böhm G, Huber CG. High-efficiency nano- and micro-HPLC--high-resolution Orbitrap-MS platform for top-down proteomics. Proteomics 2011; 10:3598-609. [PMID: 20859959 DOI: 10.1002/pmic.201000341] [Citation(s) in RCA: 40] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
In terms of resolution, mass accuracy, and sensitivity, the Orbitrap represents one of the most potent mass analyzers available today. We here elucidate the potential of interfacing Orbitrap-MS to ion-pair RP HPLC for intact protein analysis. Using gradients of ACN and monolithic columns of 1.0 and 0.10 mm id, peak capacities between 120 and 130 were achievable within 20-25 min separation time. Compared with silica-based stationary phases, protein recovery and carryover from monolithic columns were found clearly superior. Intact proteins were detectable in a mass range covering 5.7-150 kDa with LODs in the low femtomol range. Compared with UV detection, MS detection with a scanning speed of 1.6 s per spectrum on average led to a 26% increase in chromatographic peak widths, whereas chromatographic patterns were mostly preserved in extracted ion chromatograms at an acquisition rate of 0.5 s per spectrum. Isotopic resolution of multiply charged ions was demonstrated for proteins up to 42 kDa. A micro-HPLC-Orbitrap-MS setup employing a 1.0 mm id column was utilized to characterize a 150 kDa recombinant monoclonal antibody. The applicability of nano-HPLC-Orbitrap-MS to the analysis of highly complex protein mixtures is demonstrated for the 70% ethanol extractable subproteome of wheat grains.
Collapse
Affiliation(s)
- Jens Mohr
- Department of Molecular Biology, Division of Chemistry and Bioanalytics, University of Salzburg, Salzburg, Austria
| | | | | | | | | |
Collapse
|
47
|
Fonslow BR, Kang SA, Gestaut DR, Graczyk B, Davis TN, Sabatini DM, Yates JR. Native capillary isoelectric focusing for the separation of protein complex isoforms and subcomplexes. Anal Chem 2010; 82:6643-51. [PMID: 20614870 DOI: 10.1021/ac101235k] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
Here we report the use of capillary isoelectric focusing under native conditions for the separation of protein complex isoforms and subcomplexes. Using biologically relevant HIS-tag and FLAG-tag purified protein complexes, we demonstrate the separations of protein complex isoforms of the mammalian target of rapamycin complex (mTORC1 and 2) and the subcomplexes and different phosphorylation states of the Dam1 complex. The high efficiency capillary isoelectric focusing separation allowed for resolution of protein complexes and subcomplexes similar in size and biochemical composition. By performing separations with native buffers and reduced temperature (15 degrees C) we were able to maintain the complex integrity of the more thermolabile mTORC2 during isoelectric focusing and detection (<45 min). Increasing the separation temperature allowed us to monitor dissociation of the Dam1 complex into its subcomplexes (25 degrees C) and eventually its individual protein components (30 degrees C). The separation of two different phosphorylation states of the Dam1 complex, generated from an in vitro kinase assay with Mps1 kinase, was straightforward due to the large pI shift upon multiple phosphorylation events. The separation of the protein complex isoforms of mTORC, on the other hand, required the addition of a small pI range (4-6.5) of ampholytes to improve resolution and stability of the complexes. We show that native capillary isoelectric focusing is a powerful method for the difficult separations of large, similar, unstable protein complexes. This method shows potential for differentiation of protein complex isoform and subcomplex compositions, post-translational modifications, architectures, stabilities, equilibria, and relative abundances under biologically relevant conditions.
Collapse
Affiliation(s)
- Bryan R Fonslow
- Department of Chemical Physiology, The Scripps Research Institute, 10550 N. Torrey Pines Rd. La Jolla, California 92037, USA
| | | | | | | | | | | | | |
Collapse
|
48
|
Josic D, Kovac S. Reversed-phase High Performance Liquid Chromatography of proteins. CURRENT PROTOCOLS IN PROTEIN SCIENCE 2010; Chapter 8:8.7.1-8.7.22. [PMID: 20814934 DOI: 10.1002/0471140864.ps0807s61] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
Abstract
Reversed-phase HPLC (RP-HPLC) is one of most important techniques for protein separations and the method of choice for peptide separation. RP-HPLC has been applied on the nano, micro, and analytical scale, and has also been scaled up for preparative purifications, to large industrial scale. Because of its compatibility with mass spectrometry, RP-HPLC is an indispensable tool in proteomic research. With modern instrumentation and columns, complex mixtures of peptides and proteins can be separated at attomolar levels for further analysis. In addition, preparative RP-HPLC is often used for large-scale purification of proteins. This unit provides protocols for packing and testing a column, protein separation by use of gradient or step elution, desalting of protein solutions, and separation of enzymatic digests before mass spectrometric analyses. A protocol is also provided for cleaning, regenerating, and storing reversed-phase chromatography columns.
Collapse
Affiliation(s)
- Djuro Josic
- Proteomics Core, COBRE Center for Cancer Research Development, Rhode Island Hospital and Brown University, Providence, Rhode Island
| | - Spomenka Kovac
- Department of Chemistry, J. J. Strossmayer University, Osijek, Croatia
| |
Collapse
|
49
|
Esteve C, Del Río C, Marina ML, García MC. First ultraperformance liquid chromatography based strategy for profiling intact proteins in complex matrices: application to the evaluation of the performance of olive ( Olea europaea L.) stone proteins for cultivar fingerprinting. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY 2010; 58:8176-8182. [PMID: 20575522 DOI: 10.1021/jf101305t] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
There is a clear need for accelerating protein separations by HPLC. Different proposals have been developed including the use of perfusion and monolithic stationary phases. Nevertheless, these stationary phases, in some occasions, do not provide enough efficiency to resolve these large molecules when they are present in complex matrices. Although ultraperformance liquid chromatography (UPLC) columns have been successfully used for the efficient and rapid separation of small molecules, this is the first time these columns were proposed for the separation of intact proteins in a real complex matrix: the olive stone. Two different strategies were employed for the extraction of olive proteins: enzymatic assisted extraction and buffered extraction. Five different columns traditionally employed for the separation of proteins were used, and results were compared with those obtained when using different sub-2 microm particle columns. Separations obtained with sub-2 mum particle columns significantly improved the separations obtained with the other columns. This paper also demonstrates the applicability of protein profiles obtained from the olive stone for the discrimination among olive varieties.
Collapse
Affiliation(s)
- Clara Esteve
- Department of Analytical Chemistry, University of Alcala, Alcala de Henares, Madrid, Spain
| | | | | | | |
Collapse
|
50
|
High temperature liquid chromatography of intact proteins using organic polymer monoliths and alternative solvent systems. J Chromatogr A 2010; 1217:3519-24. [DOI: 10.1016/j.chroma.2010.03.033] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2009] [Revised: 01/21/2010] [Accepted: 03/19/2010] [Indexed: 11/21/2022]
|