1
|
Sathyanarayanan G, Haapala M, Sikanen T. Interfacing Digital Microfluidics with Ambient Mass Spectrometry Using SU-8 as Dielectric Layer. MICROMACHINES 2018; 9:E649. [PMID: 30544772 PMCID: PMC6316065 DOI: 10.3390/mi9120649] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/20/2018] [Revised: 11/27/2018] [Accepted: 12/06/2018] [Indexed: 01/20/2023]
Abstract
This work describes the interfacing of electrowetting-on-dielectric based digital microfluidic (DMF) sample preparation devices with ambient mass spectrometry (MS) via desorption atmospheric pressure photoionization (DAPPI). The DMF droplet manipulation technique was adopted to facilitate drug distribution and metabolism assays in droplet scale, while ambient mass spectrometry (MS) was exploited for the analysis of dried samples directly on the surface of the DMF device. Although ambient MS is well-established for bio- and forensic analyses directly on surfaces, its interfacing with DMF is scarce and requires careful optimization of the surface-sensitive processes, such as sample precipitation and the subsequent desorption/ionization. These technical challenges were addressed and resolved in this study by making use of the high mechanical, thermal, and chemical stability of SU-8. In our assay design, SU-8 served as the dielectric layer for DMF as well as the substrate material for DAPPI-MS. The feasibility of SU-8 based DMF devices for DAPPI-MS was demonstrated in the analysis of selected pharmaceuticals following on-chip liquid-liquid extraction or an enzymatic dealkylation reaction. The lower limits of detection were in the range of 1⁻10 pmol per droplet (0.25⁻1.0 µg/mL) for all pharmaceuticals tested.
Collapse
Affiliation(s)
- Gowtham Sathyanarayanan
- Drug Research Program, Faculty of Pharmacy, Division of Pharmaceutical Chemistry and Technology, University of Helsinki, Viikinkaari 5E, 00790 Helsinki, Finland.
| | - Markus Haapala
- Drug Research Program, Faculty of Pharmacy, Division of Pharmaceutical Chemistry and Technology, University of Helsinki, Viikinkaari 5E, 00790 Helsinki, Finland.
| | - Tiina Sikanen
- Drug Research Program, Faculty of Pharmacy, Division of Pharmaceutical Chemistry and Technology, University of Helsinki, Viikinkaari 5E, 00790 Helsinki, Finland.
| |
Collapse
|
2
|
|
3
|
Three-Dimensional Electro-Sonic Flow Focusing Ionization Microfluidic Chip for Mass Spectrometry. MICROMACHINES 2015. [DOI: 10.3390/mi6121463] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
4
|
Tähkä SM, Bonabi A, Nordberg ME, Kanerva M, Jokinen VP, Sikanen TM. Thiol-ene microfluidic devices for microchip electrophoresis: Effects of curing conditions and monomer composition on surface properties. J Chromatogr A 2015; 1426:233-40. [PMID: 26654831 DOI: 10.1016/j.chroma.2015.11.072] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2015] [Revised: 11/20/2015] [Accepted: 11/23/2015] [Indexed: 10/22/2022]
Abstract
Thiol-ene polymer formulations are raising growing interest as new low-cost fabrication materials for microfluidic devices. This study addresses their feasibility for microchip electrophoresis (MCE) via characterization of the effects of UV curing conditions and aging on the surface charge and wetting properties. A detailed comparison is made between stoichiometric thiol-ene (1:1) and thiol-ene formulations bearing 50% molar excess of allyls ("enes"), both prepared without photoinitiator or other polymer modifiers. Our results show that the surface charge of thiol-ene 1:1 increases along with increasing UV exposure dose until a threshold (here, about 200J/cm(2)), whereas the surface charge of thiol-ene 2:3 decreases as a function of increasing UV dose. However, no significant change in the surface charge upon storage in ambient air was observed over a period of 14 days (independent of the curing conditions). The water contact angles of thiol-ene 2:3 (typically 70-75°) were found to be less dependent on the UV dose and storing time. Instead, water contact angles of thiol-ene 1:1 slightly decrease (from initial 90 to 95° to about 70°) as a function of UV increasing exposure dose and storing time. Most importantly, both thiol-ene formulations remain relatively hydrophilic over extended periods of time, which favors their use in MCE applications. Here, MCE separation of biologically active peptides and selected fluorescent dyes is demonstrated in combination with laser-induced fluorescence detection showing high separation efficiency (theoretical plates 8200 per 4cm for peptides and 1500-2700 per 4cm for fluorescent dyes) and lower limits of detection in the sub-μM (visible range) or low-μM (near-UV range) level.
Collapse
Affiliation(s)
- Sari M Tähkä
- Division of Pharmaceutical Chemistry and Technology, Faculty of Pharmacy, FI-00014 University of Helsinki, Helsinki, Finland
| | - Ashkan Bonabi
- Division of Pharmaceutical Chemistry and Technology, Faculty of Pharmacy, FI-00014 University of Helsinki, Helsinki, Finland
| | - Maria-Elisa Nordberg
- Division of Pharmaceutical Chemistry and Technology, Faculty of Pharmacy, FI-00014 University of Helsinki, Helsinki, Finland
| | - Meeri Kanerva
- Division of Pharmaceutical Chemistry and Technology, Faculty of Pharmacy, FI-00014 University of Helsinki, Helsinki, Finland
| | - Ville P Jokinen
- Department of Materials Science and Engineering, School of Chemical Technology, Aalto University, Aalto FI-00076, Finland
| | - Tiina M Sikanen
- Division of Pharmaceutical Chemistry and Technology, Faculty of Pharmacy, FI-00014 University of Helsinki, Helsinki, Finland.
| |
Collapse
|
5
|
Lima RS, Leão PAGC, Piazzetta MHO, Monteiro AM, Shiroma LY, Gobbi AL, Carrilho E. Sacrificial adhesive bonding: a powerful method for fabrication of glass microchips. Sci Rep 2015; 5:13276. [PMID: 26293346 PMCID: PMC4543966 DOI: 10.1038/srep13276] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2015] [Accepted: 07/13/2015] [Indexed: 12/04/2022] Open
Abstract
A new protocol for fabrication of glass microchips is addressed in this research paper. Initially, the method involves the use of an uncured SU-8 intermediate to seal two glass slides irreversibly as in conventional adhesive bonding-based approaches. Subsequently, an additional step removes the adhesive layer from the channels. This step relies on a selective development to remove the SU-8 only inside the microchannel, generating glass-like surface properties as demonstrated by specific tests. Named sacrificial adhesive layer (SAB), the protocol meets the requirements of an ideal microfabrication technique such as throughput, relatively low cost, feasibility for ultra large-scale integration (ULSI), and high adhesion strength, supporting pressures on the order of 5 MPa. Furthermore, SAB eliminates the use of high temperature, pressure, or potential, enabling the deposition of thin films for electrical or electrochemical experiments. Finally, the SAB protocol is an improvement on SU-8-based bondings described in the literature. Aspects such as substrate/resist adherence, formation of bubbles, and thermal stress were effectively solved by using simple and inexpensive alternatives.
Collapse
Affiliation(s)
- Renato S Lima
- Laboratório de Microfabricação, Laboratório Nacional de Nanotecnologia, Centro Nacional de Pesquisa em Energia e Materiais, Campinas, São Paulo 13083-970, Brazil.,Instituto de Química, Universidade Estadual de Campinas, Campinas, São Paulo 13083-970, Brazil
| | - Paulo A G C Leão
- Instituto de Química de São Carlos, Universidade de São Paulo, São Carlos, São Paulo 13566-590, Brazil.,Instituto Nacional de Ciência e Tecnologia em Bioanalítica, Campinas, São Paulo 13083-970, Brazil
| | - Maria H O Piazzetta
- Laboratório de Microfabricação, Laboratório Nacional de Nanotecnologia, Centro Nacional de Pesquisa em Energia e Materiais, Campinas, São Paulo 13083-970, Brazil
| | - Alessandra M Monteiro
- Instituto de Química de São Carlos, Universidade de São Paulo, São Carlos, São Paulo 13566-590, Brazil.,Instituto Nacional de Ciência e Tecnologia em Bioanalítica, Campinas, São Paulo 13083-970, Brazil
| | - Leandro Y Shiroma
- Laboratório de Microfabricação, Laboratório Nacional de Nanotecnologia, Centro Nacional de Pesquisa em Energia e Materiais, Campinas, São Paulo 13083-970, Brazil.,Instituto de Química, Universidade Estadual de Campinas, Campinas, São Paulo 13083-970, Brazil
| | - Angelo L Gobbi
- Laboratório de Microfabricação, Laboratório Nacional de Nanotecnologia, Centro Nacional de Pesquisa em Energia e Materiais, Campinas, São Paulo 13083-970, Brazil
| | - Emanuel Carrilho
- Instituto de Química de São Carlos, Universidade de São Paulo, São Carlos, São Paulo 13566-590, Brazil.,Instituto Nacional de Ciência e Tecnologia em Bioanalítica, Campinas, São Paulo 13083-970, Brazil
| |
Collapse
|
6
|
Arscott S. SU-8 as a material for lab-on-a-chip-based mass spectrometry. LAB ON A CHIP 2014; 14:3668-3689. [PMID: 25029537 DOI: 10.1039/c4lc00617h] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
This short review focuses on the application of SU-8 for the microchip-based approach to the miniaturization of mass spectrometry. Chip-based mass spectrometry will make the technology commonplace and bring benefits such as lower costs and autonomy. The chip-based miniaturization of mass spectrometry necessitates the use of new materials which are compatible with top-down fabrication involving both planar and non-planar processes. In this context, SU-8 is a very versatile epoxy-based, negative tone resist which is sensitive to ultraviolet radiation, X-rays and electron beam exposure. It has a very wide thickness range, from nanometres to millimetres, enabling the formation of mechanically rigid, very high aspect ratio, vertical, narrow width structures required to form microfluidic slots and channels for laboratory-on-a-chip design. It is also relatively chemically resistant and biologically compatible in terms of the liquid solutions used for mass spectrometry. This review looks at the impact and potential of SU-8 on the different parts of chip-based mass spectrometry - pre-treatment, ionization processes, and ion sorting and detection.
Collapse
Affiliation(s)
- Steve Arscott
- Institut d'Electronique, de Microélectronique et de Nanotechnologie (IEMN), CNRS UMR8520, The University of Lille, Cité Scientifique, Avenue Poincaré, 59652 Villeneuve d'Ascq, France.
| |
Collapse
|
7
|
Nordman N, Barrios-Lopez B, Laurén S, Suvanto P, Kotiaho T, Franssila S, Kostiainen R, Sikanen T. Shape-anchored porous polymer monoliths for integrated online solid-phase extraction-microchip electrophoresis-electrospray ionization mass spectrometry. Electrophoresis 2014; 36:428-32. [PMID: 25043750 DOI: 10.1002/elps.201400278] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2014] [Revised: 06/30/2014] [Accepted: 07/01/2014] [Indexed: 12/22/2022]
Abstract
We report a simple protocol for fabrication of shape-anchored porous polymer monoliths (PPMs) for on-chip SPE prior to online microchip electrophoresis (ME) separation and on-chip (ESI/MS). The chip design comprises a standard ME separation channel with simple cross injector and a fully integrated ESI emitter featuring coaxial sheath liquid channel. The monolith zone was prepared in situ at the injection cross by laser-initiated photopolymerization through the microchip cover layer. The use of high-power laser allowed not only maskless patterning of a precisely defined monolith zone, but also faster exposure time (here, 7 min) compared with flood exposure UV lamps. The size of the monolith pattern was defined by the diameter of the laser output (∅500 μm) and the porosity was geared toward high through-flow to allow electrokinetic actuation and thus avoid coupling to external pumps. Placing the monolith at the injection cross enabled firm anchoring based on its cross-shape so that no surface premodification with anchoring linkers was needed. In addition, sample loading and subsequent injection (elution) to the separation channel could be performed similar to standard ME setup. As a result, 15- to 23-fold enrichment factors were obtained already at loading (preconcentration) times as short as 25 s without sacrificing the throughput of ME analysis. The performance of the SPE-ME-ESI/MS chip was repeatable within 3.1% and 11.5% RSD (n = 3) in terms of migration time and peak height, respectively, and linear correlation was observed between the loading time and peak area.
Collapse
Affiliation(s)
- Nina Nordman
- Division of Pharmaceutical Chemistry and Technology, Faculty of Pharmacy, University of Helsinki, Finland
| | | | | | | | | | | | | | | |
Collapse
|
8
|
Kalsi S, Powl AM, Wallace BA, Morgan H, de Planque MRR. Shaped apertures in photoresist films enhance the lifetime and mechanical stability of suspended lipid bilayers. Biophys J 2014; 106:1650-9. [PMID: 24739164 PMCID: PMC4008792 DOI: 10.1016/j.bpj.2014.02.033] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2013] [Revised: 02/12/2014] [Accepted: 02/26/2014] [Indexed: 11/22/2022] Open
Abstract
Planar lipid bilayers suspended in apertures provide a controlled environment for ion channel studies. However, short lifetimes and poor mechanical stability of suspended bilayers limit the experimental throughput of bilayer electrophysiology experiments. Although bilayers are more stable in smaller apertures, ion channel incorporation through vesicle fusion with the suspended bilayer becomes increasingly difficult. In an alternative bilayer stabilization approach, we have developed shaped apertures in SU8 photoresist that have tapered sidewalls and a minimum diameter between 60 and 100 μm. Bilayers formed at the thin tip of these shaped apertures, either with the painting or the folding method, display drastically increased lifetimes, typically >20 h, and mechanical stability, being able to withstand extensive perturbation of the buffer solution. Single-channel electrical recordings of the peptide alamethicin and of the proteoliposome-delivered potassium channel KcsA demonstrate channel conductance with low noise, made possible by the small capacitance of the 50 μm thick SU8 septum, which is only thinned around the aperture, and unimpeded proteoliposome fusion, enabled by the large aperture diameter. We anticipate that these shaped apertures with micrometer edge thickness can substantially enhance the throughput of channel characterization by bilayer lipid membrane electrophysiology, especially in combination with automated parallel bilayer platforms.
Collapse
Affiliation(s)
- Sumit Kalsi
- Electronics and Computer Science, University of Southampton, Southampton, United Kingdom; Institute for Life Sciences, University of Southampton, Southampton, United Kingdom.
| | - Andrew M Powl
- Institute of Structural and Molecular Biology, Birkbeck College, University of London, London, United Kingdom
| | - B A Wallace
- Institute of Structural and Molecular Biology, Birkbeck College, University of London, London, United Kingdom
| | - Hywel Morgan
- Electronics and Computer Science, University of Southampton, Southampton, United Kingdom; Institute for Life Sciences, University of Southampton, Southampton, United Kingdom
| | - Maurits R R de Planque
- Electronics and Computer Science, University of Southampton, Southampton, United Kingdom; Institute for Life Sciences, University of Southampton, Southampton, United Kingdom.
| |
Collapse
|
9
|
Mitri E, Birarda G, Vaccari L, Kenig S, Tormen M, Grenci G. SU-8 bonding protocol for the fabrication of microfluidic devices dedicated to FTIR microspectroscopy of live cells. LAB ON A CHIP 2014; 14:210-218. [PMID: 24195959 DOI: 10.1039/c3lc50878a] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
Here we present a new bonding protocol for SU-8 negative tone photoresist that exploits the chemical modifications induced in the resin by exposure to 254 nm (UVC) light. Fourier Transform Infrared microspectroscopy (μ-FTIR) was used to carry out a thorough study on the chemical processes and modifications occurring within the epoxy resin by exposure to 365 nm and 254 nm light. In particular, we established that UVC light promotes the opening of the epoxy rings bypassing the post-exposure bake. The possibility to promote a further activation of the resin, already patterned with standard UV lithography, was exploited to produce closed microfluidic devices. Specifically, we were able to fabricate fluidic chips, characterized by broadband transparency from mid-IR to UV and long term stability in continuous flow conditions. CaF2 was used as substrate, coated by sputtering with a nanometric silicon film, in order to make surface properties of this material more suitable for standard fabrication processes with respect to the original substrate. The fabricated microfluidic chips were used to study by μ-FTIR the biochemical response of live breast cancer MCF-7 cells to osmotic stress and their subsequent lysis induced by the injection of deionized water in the device. μ-FTIR analyses detected fast changes in protein, lipid and nucleic acid content as well as cytosol acidification.
Collapse
Affiliation(s)
- Elisa Mitri
- CNR-IOM, TASC laboratory, S. S. 14 km 163.5 Basovizza, 34149 Trieste, Italy.
| | | | | | | | | | | |
Collapse
|
10
|
Lima RS, Carneiro Leão PAG, Monteiro AM, de Oliveira Piazzetta MH, Gobbi AL, Mazo LH, Carrilho E. Glass/SU-8 microchip for electrokinetic applications. Electrophoresis 2013. [DOI: 10.1002/elps.201300167] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Affiliation(s)
| | | | | | | | - Angelo Luiz Gobbi
- Laboratório Nacional de Nanotecnologia; Centro Nacional de Pesquisa em Energia e Materiais; Campinas; SP; Brazil
| | - Luiz Henrique Mazo
- Instituto de Química de São Carlos; Universidade de São Paulo; São Carlos; SP; Brazil
| | | |
Collapse
|
11
|
Del Mar Barrios-Romero M, Crevillén AG, Diez-Masa JC. Development of an SDS-gel electrophoresis method on SU-8 microchips for protein separation with LIF detection: Application to the analysis of whey proteins. J Sep Sci 2013; 36:2530-7. [PMID: 23720160 DOI: 10.1002/jssc.201300275] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2013] [Revised: 05/10/2013] [Accepted: 05/13/2013] [Indexed: 02/06/2023]
Abstract
This work describes the development of an SDS-gel electrophoresis method for the analysis of major whey proteins (α-lactalbumin, β-lactoglobulin, and BSA) carried out in SU-8 microchips. The method uses a low-viscosity solution of dextran as a sieving polymer. A commercial coating agent (EOTrol LN) was added to the separation buffer to control the EOF of the chips. The potential of this coating agent to prevent protein adsorption on the walls of the SU-8 channels was also evaluated. Additionally, the fluorescence background of the SU-8 material was studied to improve the sensitivity of the method. By selecting an excitation wavelength of 532 nm at which the background fluorescence remains low and by replacing the mercury arc lamp by a laser in the detection system, an LOD in the nanomolar range was achieved for proteins derivatized with the fluorogenic reagent Chromeo P540. Finally, the method was applied to the analysis of milk samples, demonstrating the potential of SU-8 microchips for the analysis of proteins in complex food samples.
Collapse
|
12
|
Lounsbury JA, Landers JP. Ultrafast amplification of DNA on plastic microdevices for forensic short tandem repeat analysis. J Forensic Sci 2013; 58:866-74. [PMID: 23692541 DOI: 10.1111/1556-4029.12162] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2012] [Revised: 05/29/2012] [Accepted: 06/06/2012] [Indexed: 11/29/2022]
Abstract
The majority of microfluidic devices used as a platform for low-cost, rapid DNA analysis are glass devices; however, microchip fabrication in glass is costly and laborious, enhancing the interest in polymeric substrates, such as poly (methyl methacrylate) (PMMA), as an inexpensive alternative. Here, we report amplification in PMMA polymerase chain reaction (PCR) microchips providing full short tandem repeat profiles (16 of 16 loci) in 30-40 min, with peak height ratios and stutter percentages that meet literature threshold requirements. In addition, partial profiles (15 of 16 loci) were generated using an ultrafast PCR method in 17.1 min, representing a ~10-fold reduction in reaction time as compared to current amplification methods. Finally, a multichamber device was demonstrated to simultaneously amplify one positive, one negative, and five individual samples in 39 min. Although there were instances of loci dropout, this device represents a first step toward a microfluidic system capable of amplifying more than one sample simultaneously.
Collapse
Affiliation(s)
- Jenny A Lounsbury
- Department of Chemistry, University of Virginia, 409 McCormick Road, Charlottesville, VA 22904, USA
| | | |
Collapse
|
13
|
Iliescu C, Taylor H, Avram M, Miao J, Franssila S. A practical guide for the fabrication of microfluidic devices using glass and silicon. BIOMICROFLUIDICS 2012; 6:16505-1650516. [PMID: 22662101 PMCID: PMC3365353 DOI: 10.1063/1.3689939] [Citation(s) in RCA: 161] [Impact Index Per Article: 12.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/26/2011] [Accepted: 02/08/2012] [Indexed: 05/04/2023]
Abstract
This paper describes the main protocols that are used for fabricating microfluidic devices from glass and silicon. Methods for micropatterning glass and silicon are surveyed, and their limitations are discussed. Bonding methods that can be used for joining these materials are summarized and key process parameters are indicated. The paper also outlines techniques for forming electrical connections between microfluidic devices and external circuits. A framework is proposed for the synthesis of a complete glass/silicon device fabrication flow.
Collapse
|
14
|
Nordman N, Sikanen T, Moilanen ME, Aura S, Kotiaho T, Franssila S, Kostiainen R. Rapid and sensitive drug metabolism studies by SU-8 microchip capillary electrophoresis-electrospray ionization mass spectrometry. J Chromatogr A 2010; 1218:739-45. [PMID: 21185563 DOI: 10.1016/j.chroma.2010.12.010] [Citation(s) in RCA: 46] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2010] [Revised: 11/29/2010] [Accepted: 12/06/2010] [Indexed: 01/10/2023]
Abstract
Monolithically integrated, polymer (SU-8) microchips comprising an electrophoretic separation unit, a sheath flow interface, and an electrospray ionization (ESI) emitter were developed to improve the speed and throughput of metabolism research. Validation of the microchip method was performed using bufuralol 1-hydroxylation via CYP450 enzymes as the model reaction. The metabolite, 1-hydroxybufuralol, was easily separated from the substrate (R(s)=0.5) with very good detection sensitivity (LOD=9.3nM), linearity (range: 50-500nM, r(2)=0.9997), and repeatability (RSD(Area)=10.3%, RSD(Migrationtime)=2.5% at 80nM concentration without internal standard). The kinetic parameters of bufuralol 1-hydroxylation determined by the microchip capillary electrophoresis (CE)-ESI/mass spectrometry (MS) method, were comparable to the values presented in literature as well as to the values determined by in-house liquid chromatography (LC)-UV. In addition to enzyme kinetics, metabolic profiling was demonstrated using authentic urine samples from healthy volunteers after intake of either tramadol or paracetamol. As a result, six metabolites of tramadol and four metabolites of paracetamol, including both phase I oxidation products and phase II conjugation products, were detected and separated from each other within 30-35s. Before analysis, the urine samples were pre-treated with on-chip, on-line liquid-phase microextraction (LPME) and the results were compared to those obtained from urine samples pre-treated with conventional C18 solid-phase extraction (SPE, off-chip cartridges). On the basis of our results, the SU-8 CE-ESI/MS microchips incorporating on-chip sample pre-treatment, injection, separation, and ESI/MS detection were proven as efficient and versatile tools for drug metabolism research.
Collapse
Affiliation(s)
- Nina Nordman
- Division of Pharmaceutical Chemistry, Faculty of Pharmacy, University of Helsinki, Viikinkaari 5 E, 00014 University of Helsinki, Finland
| | | | | | | | | | | | | |
Collapse
|
15
|
Jin WM, Kang JH, Moon JH. Fabrication of 3D copper oxide structure by holographic lithography for photoelectrochemical electrodes. ACS APPLIED MATERIALS & INTERFACES 2010; 2:2982-2986. [PMID: 21062017 DOI: 10.1021/am100773h] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
We fabricated three-dimensional copper oxide structure by holographic lithography and electroless deposition. A five-beam interference pattern defined a woodpile structure of SU-8. The surface modification of SU-8 structure was achieved by multilayer coating of polyelectrolyte, which is critical for activating the surface for the reduction of copper. Copper was deposited onto the surface of the structure by electroless deposition, and subsequent calcinations removed the SU-8 structure and simultaneously oxidized the copper into copper oxide. The porous copper oxide structure was used as a photoelectrochemical electrode. Because of the highly porous structure, our structure showed higher photocurrent efficiency.
Collapse
Affiliation(s)
- Woo-Min Jin
- Department of Chemical and Biomolecular Engineering, Sogang University, 1 Sinsu-dong Mapo-gu, Seoul, 121-742, South Korea
| | | | | |
Collapse
|
16
|
Sikanen T, Wiedmer SK, Heikkilä L, Franssila S, Kostiainen R, Kotiaho T. Dynamic coating of SU-8 microfluidic chips with phospholipid disks. Electrophoresis 2010; 31:2566-74. [DOI: 10.1002/elps.201000130] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
|
17
|
Sikanen T, Aura S, Heikkilä L, Kotiaho T, Franssila S, Kostiainen R. Hybrid Ceramic Polymers: New, Nonbiofouling, and Optically Transparent Materials for Microfluidics. Anal Chem 2010; 82:3874-82. [DOI: 10.1021/ac1004053] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Tiina Sikanen
- Division of Pharmaceutical Chemistry, Faculty of Pharmacy, University of Helsinki, P.O. Box 56, FI-00014, Finland, Department of Micro and Nanosciences, School of Science and Technology, Aalto University, P.O. Box 13500, FI-00076, Finland, Laboratory of Analytical Chemistry, Department of Chemistry, University of Helsinki, P.O. Box 55, FI-00014, Finland, and Department of Materials Science and Engineering, School of Science and Technology, Aalto University, P.O. Box 16200, FI-00076, Finland
| | - Susanna Aura
- Division of Pharmaceutical Chemistry, Faculty of Pharmacy, University of Helsinki, P.O. Box 56, FI-00014, Finland, Department of Micro and Nanosciences, School of Science and Technology, Aalto University, P.O. Box 13500, FI-00076, Finland, Laboratory of Analytical Chemistry, Department of Chemistry, University of Helsinki, P.O. Box 55, FI-00014, Finland, and Department of Materials Science and Engineering, School of Science and Technology, Aalto University, P.O. Box 16200, FI-00076, Finland
| | - Liisa Heikkilä
- Division of Pharmaceutical Chemistry, Faculty of Pharmacy, University of Helsinki, P.O. Box 56, FI-00014, Finland, Department of Micro and Nanosciences, School of Science and Technology, Aalto University, P.O. Box 13500, FI-00076, Finland, Laboratory of Analytical Chemistry, Department of Chemistry, University of Helsinki, P.O. Box 55, FI-00014, Finland, and Department of Materials Science and Engineering, School of Science and Technology, Aalto University, P.O. Box 16200, FI-00076, Finland
| | - Tapio Kotiaho
- Division of Pharmaceutical Chemistry, Faculty of Pharmacy, University of Helsinki, P.O. Box 56, FI-00014, Finland, Department of Micro and Nanosciences, School of Science and Technology, Aalto University, P.O. Box 13500, FI-00076, Finland, Laboratory of Analytical Chemistry, Department of Chemistry, University of Helsinki, P.O. Box 55, FI-00014, Finland, and Department of Materials Science and Engineering, School of Science and Technology, Aalto University, P.O. Box 16200, FI-00076, Finland
| | - Sami Franssila
- Division of Pharmaceutical Chemistry, Faculty of Pharmacy, University of Helsinki, P.O. Box 56, FI-00014, Finland, Department of Micro and Nanosciences, School of Science and Technology, Aalto University, P.O. Box 13500, FI-00076, Finland, Laboratory of Analytical Chemistry, Department of Chemistry, University of Helsinki, P.O. Box 55, FI-00014, Finland, and Department of Materials Science and Engineering, School of Science and Technology, Aalto University, P.O. Box 16200, FI-00076, Finland
| | - Risto Kostiainen
- Division of Pharmaceutical Chemistry, Faculty of Pharmacy, University of Helsinki, P.O. Box 56, FI-00014, Finland, Department of Micro and Nanosciences, School of Science and Technology, Aalto University, P.O. Box 13500, FI-00076, Finland, Laboratory of Analytical Chemistry, Department of Chemistry, University of Helsinki, P.O. Box 55, FI-00014, Finland, and Department of Materials Science and Engineering, School of Science and Technology, Aalto University, P.O. Box 16200, FI-00076, Finland
| |
Collapse
|
18
|
Tran NT, Ayed I, Pallandre A, Taverna M. Recent innovations in protein separation on microchips by electrophoretic methods: An update. Electrophoresis 2010; 31:147-73. [DOI: 10.1002/elps.200900465] [Citation(s) in RCA: 54] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
|
19
|
Castaño-Álvarez M, Fernández-la-Villa A, Pozo-Ayuso DF, Fernández-Abedul MT, Costa-García A. Multiple-point electrochemical detection for a dual-channel hybrid PDMS-glass microchip electrophoresis device. Electrophoresis 2009; 30:3372-80. [DOI: 10.1002/elps.200900291] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
|
20
|
Ali I, Aboul-Enein HY, Gupta VK. Microchip-Based Nano Chromatography and Nano Capillary Electrophoresis in Genomics and Proteomics. Chromatographia 2008. [DOI: 10.1365/s10337-008-0813-1] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
|
21
|
Gustafsson O, Mogensen KB, Kutter JP. Underivatized cyclic olefin copolymer as substrate material and stationary phase for capillary and microchip electrochromatography. Electrophoresis 2008; 29:3145-52. [DOI: 10.1002/elps.200800131] [Citation(s) in RCA: 42] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
22
|
Sikanen T, Tuomikoski S, Ketola RA, Kostiainen R, Franssila S, Kotiaho T. Analytical characterization of microfabricated SU-8 emitters for electrospray ionization mass spectrometry. JOURNAL OF MASS SPECTROMETRY : JMS 2008; 43:726-735. [PMID: 18205241 DOI: 10.1002/jms.1368] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
We present a detailed optimization and characterization of the analytical performance of SU-8-based emitters for electrospray ionization mass spectrometry (ESI/MS). The improved SU-8 fabrication process presented here enhances patterning accuracy and reduces the time and cost of fabrication. All emitters are freestanding and enable sample delivery by both pressure-driven and spontaneous flows. The optimized emitter design incorporates a sharp, double-cantilevered tip implemented to the outlet of an SU-8 microchannel and provides highly sensitive ESI/MS detection. Moreover, the optimized design allows the use of relatively large microchannel dimensions (up to 200 x 50 microm(2), w x h) without sacrificing the detection sensitivity. This is advantageous with a view of preventing emitter clogging and enabling reproducible analysis. The measured limits of detection for the optimized emitter design were 1 nM for verapamil and 4 nM for Glu-fibrinopeptide B with good quantitative linearities between 1 nM and 10 microM (R(2) = 0.9998) for verapamil and between 4 nM and 3 microM (R(2) = 0.9992) for Glu-fibrinopeptide B. The measured tip-to-tip repeatability for signal intensity was 14% relative standard deviation (RSD) (n = 3; 5 microM verapamil) and run-to-run repeatability 4-11% RSD (n = 4; 5 microM verapamil) for all individual emitters tested. In addition, long-term stability of < 2% RSD was maintained for timescales of 30 min even under free flow conditions. SU-8 polymer was also shown to be chemically stable against most of the tested electrospray solvents.
Collapse
Affiliation(s)
- Tiina Sikanen
- Laboratory of Analytical Chemistry, Department of Chemistry, FI-00014 University of Helsinki, Helsinki, Finland
| | | | | | | | | | | |
Collapse
|