1
|
Kováč A, Majerová P, Nytka M, Cechová MZ, Bednář P, Hájek R, Cooper-Shepherd DA, Muck A, Lemr K. Separation of Isomeric Tau Phosphopeptides from Alzheimer's Disease Brain by Cyclic Ion Mobility Mass Spectrometry. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2023; 34:394-400. [PMID: 36706338 PMCID: PMC10017020 DOI: 10.1021/jasms.2c00289] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/10/2022] [Revised: 01/04/2023] [Accepted: 01/06/2023] [Indexed: 06/18/2023]
Abstract
Alzheimer's disease (AD) is a neurodegenerative disorder of increasing concern. It belongs to diseases termed tauopathies which are characterized by inclusions of abnormally hyperphosphorylated and truncated forms of the protein tau. Studies of tauopathies often focus on detection and characterization of these aberrant tau proteoforms, in particular the phosphorylation sites, which represent a significant analytical challenge for example when several phosphosites can be present on the same peptide. Such isomers can even be difficult to fully separate chromatographically. Since recently introduced cyclic ion mobility-mass spectrometry can offer different selectivity, we have investigated the closely positioned phosphorylation sites S214, T212, and T217 of a tryptic peptide from proline rich region of tau-TPSLPTPPTREPK. The conformational heterogeneity of the isomeric peptides in the gas phase hindered their separation due to their overlapping arrival time distributions. Increasing the resolution of the analysis alone is insufficient to distinguish the peptides in a mixture typical of patient samples. We therefore developed a method based on a combination of collision-induced dissociation, isomeric product ions (m/z 677) mobility separation and post-mobility dissociation to aid in analyzing the isomeric phosphopeptides of tau in diseased brain extract. For all three isomers (T212, S214, and T217), the ion mobility signal of the ion at m/z 677 was still observable at the concentration of 0.1 nmol/L. This work not only offers insights into the phosphorylation of tau protein in AD but also provides an analytical workflow for the characterization of challenging pathological protein modifications in neurodegenerative diseases.
Collapse
Affiliation(s)
- Andrej Kováč
- Institute
of Neuroimmunology, Slovak Academy of Sciences, Dúbravská cesta 9, 845 10 Bratislava, Slovak Republic
| | - Petra Majerová
- Axon
Neuroscience R&D Services SE, Dvořákovo nábrežie 10, 811 02 Bratislava, Slovak Republic
| | - Marianna Nytka
- Department
of Analytical Chemistry, Faculty of Science, Palacky University, 17 listopadu 12, 771 46 Olomouc, Czech Republic
| | - Monika Zajacová Cechová
- Department
of Analytical Chemistry, Faculty of Science, Palacky University, 17 listopadu 12, 771 46 Olomouc, Czech Republic
| | - Petr Bednář
- Department
of Analytical Chemistry, Faculty of Science, Palacky University, 17 listopadu 12, 771 46 Olomouc, Czech Republic
| | - Roman Hájek
- Waters
Corporation, Stamford Avenue, Altrincham Road, Wilmslow SK9 4AX, United Kingdom
| | | | - Alexander Muck
- Waters
Corporation, Stamford Avenue, Altrincham Road, Wilmslow SK9 4AX, United Kingdom
| | - Karel Lemr
- Department
of Analytical Chemistry, Faculty of Science, Palacky University, 17 listopadu 12, 771 46 Olomouc, Czech Republic
- Institute
of Microbiology of the Czech Academy of Sciences, Vídeňská 1083, 142 20 Prague, Czech Republic
| |
Collapse
|
2
|
High-end ion mobility mass spectrometry: A current review of analytical capacity in omics applications and structural investigations. Trends Analyt Chem 2022. [DOI: 10.1016/j.trac.2022.116761] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|
3
|
Ieritano C, Hopkins WS. The hitchhiker's guide to dynamic ion-solvent clustering: applications in differential ion mobility spectrometry. Phys Chem Chem Phys 2022; 24:20594-20615. [PMID: 36000315 DOI: 10.1039/d2cp02540j] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
This article highlights the fundamentals of ion-solvent clustering processes that are pertinent to understanding an ion's behaviour during differential mobility spectrometry (DMS) experiments. We contrast DMS with static-field ion mobility, where separation is affected by mobility differences under the high-field and low-field conditions of an asymmetric oscillating electric field. Although commonly used in mass spectrometric (MS) workflows to enhance signal-to-noise ratios and remove isobaric contaminants, the chemistry and physics that underpins the phenomenon of differential mobility has yet to be fully fleshed out. Moreover, we are just now making progress towards understanding how the DMS separation waveform creates a dynamic clustering environment when the carrier gas is seeded with the vapour of a volatile solvent molecule (e.g., methanol). Interestingly, one can correlate the dynamic clustering behaviour observed in DMS experiments with gas-phase and solution-phase molecular properties such as hydrophobicity, acidity, and solubility. However, to create a generalized, global model for property determination using DMS data one must employ machine learning. In this article, we provide a first-principles description of differential ion mobility in a dynamic clustering environment. We then discuss the correlation between dynamic clustering propensity and analyte physicochemical properties and demonstrate that analytes exhibiting similar ion-solvent interactions (e.g., charge-dipole) follow well-defined trends with respect to DMS clustering behaviour. Finally, we describe how supervised machine learning can be used to create predictive models of molecular properties using DMS data. We additionally highlight open questions in the field and provide our perspective on future directions that can be explored.
Collapse
Affiliation(s)
- Christian Ieritano
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, Ontario, N2L 3G1, Canada. .,Waterloo Institute for Nanotechnology, University of Waterloo, 200 University Avenue West, Waterloo, Ontario, N2L 3G1, Canada.,Watermine Innovation, Waterloo, Ontario, N0B 2T0, Canada
| | - W Scott Hopkins
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, Ontario, N2L 3G1, Canada. .,Waterloo Institute for Nanotechnology, University of Waterloo, 200 University Avenue West, Waterloo, Ontario, N2L 3G1, Canada.,Watermine Innovation, Waterloo, Ontario, N0B 2T0, Canada.,Centre for Eye and Vision Research, 17W Hong Kong Science Park, New Territories, 999077, Hong Kong
| |
Collapse
|
4
|
Srinivasan A, Sing JC, Gingras AC, Röst HL. Improving Phosphoproteomics Profiling Using Data-Independent Mass Spectrometry. J Proteome Res 2022; 21:1789-1799. [PMID: 35877786 DOI: 10.1021/acs.jproteome.2c00172] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Mass spectrometry-based profiling of the phosphoproteome is a powerful method of identifying phosphorylation events at a systems level. Most phosphoproteomics studies have used data-dependent acquisition (DDA) mass spectrometry as their method of choice. In this Perspective, we review some recent studies benchmarking DDA and DIA methods for phosphoproteomics and discuss data analysis options for DIA phosphoproteomics. In order to evaluate the impact of data-dependent and data-independent acquisition (DIA) on identification and quantification, we analyze a previously published phosphopeptide-enriched data set consisting of 10 replicates acquired by DDA and DIA each. We find that though more unique identifications are made in DDA data, phosphopeptides are identified more consistently across replicates in DIA. We further discuss the challenges of identifying chromatographically coeluting phosphopeptide isomers and investigate the impact on reproducibility of identifying high-confidence site-localized phosphopeptides in replicates.
Collapse
Affiliation(s)
- Aparna Srinivasan
- Department of Molecular Genetics, University of Toronto, Toronto, Ontario M5S 1A8, Canada.,Lunenfeld Tanenbaum Research Institute, Mount Sinai Hospital, Toronto, Ontario M5G 1X5, Canada.,Donnelly Centre for Cellular and Biomolecular Research, University of Toronto, Toronto, Ontario M5S 3E1, Canada
| | - Justin C Sing
- Department of Molecular Genetics, University of Toronto, Toronto, Ontario M5S 1A8, Canada.,Donnelly Centre for Cellular and Biomolecular Research, University of Toronto, Toronto, Ontario M5S 3E1, Canada
| | - Anne-Claude Gingras
- Department of Molecular Genetics, University of Toronto, Toronto, Ontario M5S 1A8, Canada.,Lunenfeld Tanenbaum Research Institute, Mount Sinai Hospital, Toronto, Ontario M5G 1X5, Canada
| | - Hannes L Röst
- Department of Molecular Genetics, University of Toronto, Toronto, Ontario M5S 1A8, Canada.,Donnelly Centre for Cellular and Biomolecular Research, University of Toronto, Toronto, Ontario M5S 3E1, Canada
| |
Collapse
|
5
|
Hariri M, Jafari MT, Jazan E. Investigation of different alcoholic modifiers for the separation and determination of two isomers of dinitrotoluene (2,4 and 2,6) by ion mobility spectrometry. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2022; 36:e9274. [PMID: 35178790 DOI: 10.1002/rcm.9274] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/05/2021] [Revised: 12/04/2021] [Accepted: 01/31/2022] [Indexed: 06/14/2023]
Abstract
Some alcoholic modifier gases were applied to separate isomer peaks in ion mobility spectrometry (IMS). Different mechanisms have been investigated on the separation, such as collision cross-section and analyte-modifier cluster formation. In this regard, some parameters that affected the cluster formation, such as dipole moment, electron affinity, the position of functional groups, and the modifier structure, were evaluated. On the other hand, some effective experimental parameters, including cell temperature and the flow rates of the drift and modifier gases, were also optimized. The combination of dispersive liquid-liquid microextraction with thin-film evaporation (DLLME-TFE) was used as a sample preparation method for the extraction of 2,4-dinitrotoluene (2,4-DNT) and 2,6-dinitrotoluene (2,6-DNT) isomers (as the target analytes). Isobutanol was selected as the alcoholic modifier to separate the ion molecular peaks of these isomers. The limit of detection and the limit of quantification obtained were 15 and 50 μg L-1 , and the linear dynamic range (50-700 μg L-1 ) with coefficient of determination of 0.9941 and 0.9914 were obtained for 2,4-DNT and 2,6-DNT, respectively. The intra- and inter-day relative standard deviations were obtained between 3% and 5%. For validation of the method, determination of the isomers was accomplished for a red wastewater field sample, resulting in relative recovery values of about 96%.
Collapse
Affiliation(s)
- Mohammad Hariri
- Department of Chemistry, Isfahan University of Technology, Isfahan, Iran
| | - Mohammad T Jafari
- Department of Chemistry, Isfahan University of Technology, Isfahan, Iran
| | - Elham Jazan
- Department of Chemistry, Shahreza Branch, Islamic Azad University, Isfahan, Iran
| |
Collapse
|
6
|
Mastellone J, Kabir KM, Huang X, Donald WA. Separation of disaccharide epimers, anomers and connectivity isomers by high resolution differential ion mobility mass spectrometry. Anal Chim Acta 2022; 1206:339783. [DOI: 10.1016/j.aca.2022.339783] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2022] [Revised: 03/25/2022] [Accepted: 03/26/2022] [Indexed: 11/15/2022]
|
7
|
Abstract
Protein post-translational modifications (PTMs) enable cells to rapidly change in response to biological stimuli. With hundreds of different PTMs, understanding these control mechanisms is complex. To date, efforts have focused on investigating the effect of a single PTM on protein function. Yet, many proteins contain multiple PTMs. Moreover, one PTM can alter the prevalence of another, a phenomenon termed PTM crosstalk. Understanding PTM crosstalk is critical; however, its detection is challenging since PTMs occur substoichiometrically. Here, we develop an enrichment-free, label-free proteomics method that utilizes high-field asymmetric ion mobility spectrometry (FAIMS) to enhance the detection of PTM crosstalk. We show that by searching for multiple combinations of dynamic PTMs on peptide sequences, a 6-fold increase in candidate PTM crosstalk sites is identified compared with that of standard liquid chromatography-tandem mass spectrometry (LC-MS/MS) workflows. Additionally, by cycling through FAIMS compensation voltages within a single LC-FAIMS-MS/MS run, we show that our LC-FAIMS-MS/MS workflow can increase multi-PTM-containing peptide identifications without additional increases in run times. With 159 novel candidate crosstalk sites identified, we envisage LC-FAIMS-MS/MS to play an important role in expanding the repertoire of multi-PTM identifications. Moreover, it is only by detecting PTM crosstalk that we can "see" the full picture of how proteins are regulated.
Collapse
Affiliation(s)
- Kish R. Adoni
- School of Biosciences, University of Birmingham, Edgbaston, Birmingham B15 2TT, U.K.
| | - Debbie L. Cunningham
- School of Biosciences, University of Birmingham, Edgbaston, Birmingham B15 2TT, U.K.
| | - John K. Heath
- School of Biosciences, University of Birmingham, Edgbaston, Birmingham B15 2TT, U.K.
| | - Aneika C. Leney
- School of Biosciences, University of Birmingham, Edgbaston, Birmingham B15 2TT, U.K.
| |
Collapse
|
8
|
Phosphoproteomics Sample Preparation Impacts Biological Interpretation of Phosphorylation Signaling Outcomes. Cells 2021; 10:cells10123407. [PMID: 34943915 PMCID: PMC8699897 DOI: 10.3390/cells10123407] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2021] [Revised: 11/28/2021] [Accepted: 12/01/2021] [Indexed: 01/02/2023] Open
Abstract
The influence of phosphoproteomics sample preparation methods on the biological interpretation of signaling outcome is unclear. Here, we demonstrate a strong bias in phosphorylation signaling targets uncovered by comparing the phosphoproteomes generated by two commonly used methods-strong cation exchange chromatography-based phosphoproteomics (SCXPhos) and single-run high-throughput phosphoproteomics (HighPhos). Phosphoproteomes of embryonic stem cells exposed to ionizing radiation (IR) profiled by both methods achieved equivalent coverage (around 20,000 phosphosites), whereas a combined dataset significantly increased the depth (>30,000 phosphosites). While both methods reproducibly quantified a subset of shared IR-responsive phosphosites that represent DNA damage and cell-cycle-related signaling events, most IR-responsive phosphoproteins (>82%) and phosphosites (>96%) were method-specific. Both methods uncovered unique insights into phospho-signaling mediated by single (SCXPhos) versus double/multi-site (HighPhos) phosphorylation events; particularly, each method identified a distinct set of previously unreported IR-responsive kinome/phosphatome (95% disparate) directly impacting the uncovered biology.
Collapse
|
9
|
Ieritano C, Lee A, Crouse J, Bowman Z, Mashmoushi N, Crossley PM, Friebe BP, Campbell JL, Hopkins WS. Determining Collision Cross Sections from Differential Ion Mobility Spectrometry. Anal Chem 2021; 93:8937-8944. [PMID: 34132546 DOI: 10.1021/acs.analchem.1c01420] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
The experimental determination of ion-neutral collision cross sections (CCSs) is generally confined to ion mobility spectrometry (IMS) technologies that operate under the so-called low-field limit or those that enable empirical calibration strategies (e.g., traveling wave IMS; TWIMS). Correlation of ion trajectories to CCS in other non-linear IMS techniques that employ dynamic electric fields, such as differential mobility spectrometry (DMS), has remained a challenge since its inception. Here, we describe how an ion's CCS can be measured from DMS experiments using a machine learning (ML)-based calibration. The differential mobility of 409 molecular cations (m/z: 86-683 Da and CCS 110-236 Å2) was measured in a N2 environment to train the ML framework. Several open-source ML routines were tested and trained using DMS-MS data in the form of the parent ion's m/z and the compensation voltage required for elution at specific separation voltages between 1500 and 4000 V. The best performing ML model, random forest regression, predicted CCSs with a mean absolute percent error of 2.6 ± 0.4% for analytes excluded from the training set (i.e., out-of-the-bag external validation). This accuracy approaches the inherent statistical error of ∼2.2% for the MobCal-MPI CCS calculations employed for training purposes and the <2% threshold for matching literature CCSs with those obtained on a TWIMS platform.
Collapse
Affiliation(s)
- Christian Ieritano
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo N2L 3G1, Ontario, Canada
- WaterMine Innovation, Inc., Waterloo N0B 2T0, Ontario, Canada
- Waterloo Institute for Nanotechnology, University of 200 University Avenue West, Waterloo N2L 3G1, Ontario, Canada
| | - Arthur Lee
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo N2L 3G1, Ontario, Canada
- WaterMine Innovation, Inc., Waterloo N0B 2T0, Ontario, Canada
- Waterloo Institute for Nanotechnology, University of 200 University Avenue West, Waterloo N2L 3G1, Ontario, Canada
| | - Jeff Crouse
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo N2L 3G1, Ontario, Canada
- WaterMine Innovation, Inc., Waterloo N0B 2T0, Ontario, Canada
| | - Zack Bowman
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo N2L 3G1, Ontario, Canada
| | - Nour Mashmoushi
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo N2L 3G1, Ontario, Canada
- Waterloo Institute for Nanotechnology, University of 200 University Avenue West, Waterloo N2L 3G1, Ontario, Canada
| | - Paige M Crossley
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo N2L 3G1, Ontario, Canada
| | - Benjamin P Friebe
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo N2L 3G1, Ontario, Canada
| | - J Larry Campbell
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo N2L 3G1, Ontario, Canada
- WaterMine Innovation, Inc., Waterloo N0B 2T0, Ontario, Canada
- Bedrock Scientific Inc., Milton, L6T 6J9, Ontario, Canada
| | - W Scott Hopkins
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo N2L 3G1, Ontario, Canada
- WaterMine Innovation, Inc., Waterloo N0B 2T0, Ontario, Canada
- Waterloo Institute for Nanotechnology, University of 200 University Avenue West, Waterloo N2L 3G1, Ontario, Canada
- Centre for Eye and Vision Research, Hong Kong Science Park, New Territories 999077, Hong Kong
| |
Collapse
|
10
|
Ieritano C, Rickert D, Featherstone J, Honek JF, Campbell JL, Blanc JCYL, Schneider BB, Hopkins WS. The Charge-State and Structural Stability of Peptides Conferred by Microsolvating Environments in Differential Mobility Spectrometry. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2021; 32:956-968. [PMID: 33733774 DOI: 10.1021/jasms.0c00469] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
The presence of solvent vapor in a differential mobility spectrometry (DMS) cell creates a microsolvating environment that can mitigate complications associated with field-induced heating. In the case of peptides, the microsolvation of protonation sites results in a stabilization of charge density through localized solvent clustering, sheltering the ion from collisional activation. Seeding the DMS carrier gas (N2) with a solvent vapor prevented nearly all field-induced fragmentation of the protonated peptides GGG, AAA, and the Lys-rich Polybia-MP1 (IDWKKLLDAAKQIL-NH2). Modeling the microsolvation propensity of protonated n-propylamine [PrNH3]+, a mimic of the Lys side chain and N-terminus, with common gas-phase modifiers (H2O, MeOH, EtOH, iPrOH, acetone, and MeCN) confirms that all solvent molecules form stable clusters at the site of protonation. Moreover, modeling populations of microsolvated clusters indicates that species containing protonated amine moieties exist as microsolvated species with one to six solvent ligands at all effective ion temperatures (Teff) accessible during a DMS experiment (ca. 375-600 K). Calculated Teff of protonated GGG, AAA, and Polybia-MPI using a modified two-temperature theory approach were up to 86 K cooler in DMS environments seeded with solvent vapor compared to pure N2 environments. Stabilizing effects were largely driven by an increase in the ion's apparent collision cross section and by evaporative cooling processes induced by the dynamic evaporation/condensation cycles incurred in the presence of an oscillating electric separation field. When the microsolvating partner was a protic solvent, abstraction of a proton from [MP1 + 3H]3+ to yield [MP1 + 2H]2+ was observed. This result was attributed to the proclivity of protic solvents to form hydrogen-bond networks with enhanced gas-phase basicity. Collectively, microsolvation provides analytes with a solvent "air bag," whereby charge reduction and microsolvation-induced stabilization were shown to shelter peptides from the fragmentation induced by field heating and may play a role in preserving native-like ion configurations.
Collapse
Affiliation(s)
- Christian Ieritano
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo N2L 3G1, Ontario, Canada
| | - Daniel Rickert
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo N2L 3G1, Ontario, Canada
| | - Joshua Featherstone
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo N2L 3G1, Ontario, Canada
| | - John F Honek
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo N2L 3G1, Ontario, Canada
| | - J Larry Campbell
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo N2L 3G1, Ontario, Canada
- Watermine Innovation, Waterloo N0B 2T0, Ontario, Canada
- Bedrock Scientific, Milton L6T 6J9, Ontario, Canada
| | | | | | - W Scott Hopkins
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo N2L 3G1, Ontario, Canada
- Watermine Innovation, Waterloo N0B 2T0, Ontario, Canada
- Waterloo Institute for Nanotechnology, University of Waterloo, 200 University Avenue West, Waterloo N2L 3G1, Ontario, Canada
- Centre for Eye and Vision Research, Hong Kong Science Park, New Territories 999077, Hong Kong
| |
Collapse
|
11
|
Besada V, Ramos Y, Espinosa LA, Fu W, Perera Y, González LJ. FAIMS-MS might contribute to phosphopeptides identification in plasma. J Proteomics 2021; 234:104102. [PMID: 33412312 DOI: 10.1016/j.jprot.2021.104102] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/26/2020] [Accepted: 01/03/2021] [Indexed: 01/24/2023]
Abstract
FAIMS interface is gaining popularity because of the impressive 100-fold signal to noise enhancement in addition to the recent coupling to the Orbitrap technology, the most important analyzer developed in the last 20 years. The selection of group of ions and effective removal of single-charged ones at particular compensation voltages increases around 50% the proteome coverage at expenses of lower peptides coverage. However, specific setting for phosphoproteome analysis is yet poorly described. Here we have found the maximum transmission for several tryptic phosphopeptides isolated from a single complex mixture and we have set an experimental method based on five compensation voltages partially different to the ones described previously, demonstrating the relevance of voltages higher than 47 V, with an increase of around 20% of unique phosphopeptides. Using this experimental setup two complex phosphoproteomes isolates (SH-SY5Y cell line and plasma) were analyzed and found increments of 50% on phosphopeptides identification with the proposed method with respect to a previous one, for the cell line extract. Meanwhile for plasma 109 of the detected phosphopeptides are found for first time in this body fluid, presumably due to the release of intracellular proteins. With this FAIMS setup, 60% of the proteins identified are classified as very low abundant proteins.
Collapse
Affiliation(s)
- V Besada
- Mass Spectrometry Laboratory, Department of Proteomics, Center for Genetic Engineering and Biotechnology (CIGB), Havana CP: 10600, Cuba; Proteomics Laboratory, China-Cuba Biotechnology Joint Innovation Center (CCBJIC), Yongzhou Zhong Gu Biotechnology Co., Ltd, Yangjiaqiao Street, Lengshuitan District, Yongzhou City, Hunan Province CP: 425000, China.
| | - Y Ramos
- Mass Spectrometry Laboratory, Department of Proteomics, Center for Genetic Engineering and Biotechnology (CIGB), Havana CP: 10600, Cuba.
| | - L A Espinosa
- Mass Spectrometry Laboratory, Department of Proteomics, Center for Genetic Engineering and Biotechnology (CIGB), Havana CP: 10600, Cuba.
| | - W Fu
- Proteomics Laboratory, China-Cuba Biotechnology Joint Innovation Center (CCBJIC), Yongzhou Zhong Gu Biotechnology Co., Ltd, Yangjiaqiao Street, Lengshuitan District, Yongzhou City, Hunan Province CP: 425000, China.
| | - Y Perera
- Mass Spectrometry Laboratory, Department of Proteomics, Center for Genetic Engineering and Biotechnology (CIGB), Havana CP: 10600, Cuba; Proteomics Laboratory, China-Cuba Biotechnology Joint Innovation Center (CCBJIC), Yongzhou Zhong Gu Biotechnology Co., Ltd, Yangjiaqiao Street, Lengshuitan District, Yongzhou City, Hunan Province CP: 425000, China.
| | - L J González
- Mass Spectrometry Laboratory, Department of Proteomics, Center for Genetic Engineering and Biotechnology (CIGB), Havana CP: 10600, Cuba.
| |
Collapse
|
12
|
Muehlbauer LK, Hebert AS, Westphall MS, Shishkova E, Coon JJ. Global Phosphoproteome Analysis Using High-Field Asymmetric Waveform Ion Mobility Spectrometry on a Hybrid Orbitrap Mass Spectrometer. Anal Chem 2020; 92:15959-15967. [PMID: 33270415 DOI: 10.1021/acs.analchem.0c03415] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Mass spectrometry is the premier tool for identifying and quantifying protein phosphorylation on a global scale. Analysis of phosphopeptides requires enrichment, and even after the samples remain highly complex and exhibit broad dynamic range of abundance. Achieving maximal depth of coverage for phosphoproteomics therefore typically necessitates offline liquid chromatography prefractionation, a time-consuming and laborious approach. Here, we incorporate a recently commercialized aerodynamic high-field asymmetric waveform ion mobility spectrometry (FAIMS) device into the phosphoproteomic workflow. We characterize the effects of phosphorylation on the FAIMS separation, describe optimized compensation voltage settings for unlabeled phosphopeptides, and demonstrate the advantages of FAIMS-enabled gas-phase fractionation. Standard FAIMS single-shot analyses identified around 15-20% additional phosphorylation sites than control experiments without FAIMS. In comparison to liquid chromatography prefractionation, FAIMS experiments yielded similar or superior results when analyzing up to four discrete gas-phase fractions. Although using FAIMS led to a modest reduction in the precision of quantitative measurements when using label-free approaches, the data collected with FAIMS yielded a 26% increase in total reproducible measurements. Overall, we conclude that the new FAIMS technology is a valuable addition to any phosphoproteomic workflow, with greater benefits emerging from longer analyses and higher amounts of material.
Collapse
Affiliation(s)
- Laura K Muehlbauer
- National Center for Quantitative Biology of Complex Systems, University of Wisconsin-Madison, Madison, Wisconsin 53706, United States.,Department of Chemistry, University of Wisconsin-Madison, Madison, Wisconsin, 53706, United States
| | - Alexander S Hebert
- National Center for Quantitative Biology of Complex Systems, University of Wisconsin-Madison, Madison, Wisconsin 53706, United States.,Department of Biomolecular Chemistry, University of Wisconsin-Madison, Madison, Wisconsin, 53706, United States
| | - Michael S Westphall
- National Center for Quantitative Biology of Complex Systems, University of Wisconsin-Madison, Madison, Wisconsin 53706, United States.,Department of Biomolecular Chemistry, University of Wisconsin-Madison, Madison, Wisconsin, 53706, United States
| | - Evgenia Shishkova
- National Center for Quantitative Biology of Complex Systems, University of Wisconsin-Madison, Madison, Wisconsin 53706, United States.,Department of Biomolecular Chemistry, University of Wisconsin-Madison, Madison, Wisconsin, 53706, United States
| | - Joshua J Coon
- National Center for Quantitative Biology of Complex Systems, University of Wisconsin-Madison, Madison, Wisconsin 53706, United States.,Department of Chemistry, University of Wisconsin-Madison, Madison, Wisconsin, 53706, United States.,Department of Biomolecular Chemistry, University of Wisconsin-Madison, Madison, Wisconsin, 53706, United States.,Morgridge Institute for Research, Madison, Wisconsin 53706, United States
| |
Collapse
|
13
|
Campbell JL, Kafle A, Bowman Z, Blanc JCYL, Liu C, Hopkins WS. Separating chiral isomers of amphetamine and methamphetamine using chemical derivatization and differential mobility spectrometry. ACTA ACUST UNITED AC 2020. [DOI: 10.1002/ansa.202000066] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Affiliation(s)
- J. Larry Campbell
- SCIEX Concord Ontario Canada
- Department of Chemistry University of Waterloo 200 University Avenue West Waterloo Ontario Canada
- Bedrock Scientific Milton Ontario Canada
- WaterMine Innovation, Inc. Waterloo Ontario Canada
| | | | - Zack Bowman
- Department of Chemistry University of Waterloo 200 University Avenue West Waterloo Ontario Canada
- Waterloo Institute for Nanotechnology University of 200 University Avenue West Waterloo Ontario Canada
| | | | | | - W. Scott Hopkins
- Department of Chemistry University of Waterloo 200 University Avenue West Waterloo Ontario Canada
- Waterloo Institute for Nanotechnology University of 200 University Avenue West Waterloo Ontario Canada
- WaterMine Innovation, Inc. Waterloo Ontario Canada
| |
Collapse
|
14
|
Lam KHB, Le Blanc JCY, Campbell JL. Separating Isomers, Conformers, and Analogues of Cyclosporin using Differential Mobility Spectroscopy, Mass Spectrometry, and Hydrogen–Deuterium Exchange. Anal Chem 2020; 92:11053-11061. [DOI: 10.1021/acs.analchem.0c00191] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Affiliation(s)
- K. H. Brian Lam
- Department of Chemistry and Centre for Research in Mass Spectrometry, York University, 4700 Keele Street, Toronto, Ontario M3J 1P3, Canada
| | | | - J. Larry Campbell
- SCIEX, 71 Four Valley Drive, Concord, Ontario L4K 4 V8, Canada
- Department of Chemistry, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada
| |
Collapse
|
15
|
Pathak P, Baird MA, Shvartsburg AA. High-Resolution Ion Mobility Separations of Isomeric Glycoforms with Variations on the Peptide and Glycan Levels. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2020; 31:1603-1609. [PMID: 32501708 DOI: 10.1021/jasms.0c00183] [Citation(s) in RCA: 30] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Glycosylation is a ubiquitous post-translational modification (PTM) that strongly affects the protein folding and function. Glycosylation patterns are impacted by many diseases, making promising biomarkers. Glycans are also the most complex PTMs, exhibiting isomers (linkage, anomers, and those with isomeric moieties). Permuted with localization variants that occur for all PTMs, these produce numerous isomeric glycoforms. Characterizing them by mass spectrometry and ion mobility spectrometry (IMS) has been a challenge. High-definition differential IMS (FAIMS) had robustly disentangled isomeric peptides involving other PTMs but was not evaluated for glycopeptides that featured multilevel isomerism. Here, we apply it to representative mucin glycopeptides with O-linked glycans: three GalNAc localization variants, a pair with α/β GalNAc anomers, and another with GalNAc/GlcNAc isomers. The first two classes were separated baseline with the resolution exceeding previous benchmarks by 10-fold, and the last pair was partly resolved. The recently demonstrated straightforward coupling to ultrahigh-resolution MS and electron-transfer dissociation makes high-definition FAIMS an attractive tool for glycoproteomics.
Collapse
Affiliation(s)
- Pratima Pathak
- Department of Chemistry, Wichita State University, 1845 Fairmount, Wichita, Kansas 67260, United States
| | - Matthew A Baird
- Department of Chemistry, Wichita State University, 1845 Fairmount, Wichita, Kansas 67260, United States
| | - Alexandre A Shvartsburg
- Department of Chemistry, Wichita State University, 1845 Fairmount, Wichita, Kansas 67260, United States
| |
Collapse
|
16
|
Lu G, Xu X, Li G, Sun H, Wang N, Zhu Y, Wan N, Shi Y, Wang G, Li L, Hao H, Ye H. Subresidue-Resolution Footprinting of Ligand-Protein Interactions by Carbene Chemistry and Ion Mobility-Mass Spectrometry. Anal Chem 2020; 92:947-956. [PMID: 31769969 PMCID: PMC7394559 DOI: 10.1021/acs.analchem.9b03827] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
The knowledge of ligand-protein interactions is essential for understanding fundamental biological processes and for the rational design of drugs that target such processes. Carbene footprinting efficiently labels proteinaceous residues and has been used with mass spectrometry (MS) to map ligand-protein interactions. Nevertheless, previous footprinting studies are typically performed at the residue level, and therefore, the resolution may not be high enough to couple with conventional crystallography techniques. Herein we developed a subresidue footprinting strategy based on the discovery that carbene labeling produces subresidue peptide isomers and the intensity changes of these isomers in response to ligand binding can be exploited to delineate ligand-protein topography at the subresidue level. The established workflow combines carbene footprinting, extended liquid chromatographic separation, and ion mobility (IM)-MS for efficient separation and identification of subresidue isomers. Analysis of representative subresidue isomers located within the binding cleft of lysozyme and those produced from an amyloid-β segment have both uncovered structural information heretofore unavailable by residue-level footprinting. Lastly, a "real-world" application shows that the reactivity changes of subresidue isomers at Phe399 can identify the interactive nuances between estrogen-related receptor α, a potential drug target for cancer and metabolic diseases, with its three ligands. These findings have significant implications for drug design. Taken together, we envision the subresidue-level resolution enabled by IM-MS-coupled carbene footprinting can bridge the gap between structural MS and the more-established biophysical tools and ultimately facilitate diverse applications for fundamental research and pharmaceutical development.
Collapse
Affiliation(s)
- Gaoyuan Lu
- School of Pharmacy, China Pharmaceutical University, Tongjiaxiang #24, Nanjing, Jiangsu 210009, China
| | - Xiaowei Xu
- Key Laboratory of Drug Metabolism and Pharmacokinetics, State Key Laboratory of Natural Medicines, China Pharmaceutical University, Tongjiaxiang #24, Nanjing, Jiangsu 210009, China
| | - Gongyu Li
- School of Pharmacy, University of Wisconsin-Madison, 777 Highland Avenue, Madison, Wisconsin 53706, United States
| | - Huiyong Sun
- School of Pharmacy, China Pharmaceutical University, Tongjiaxiang #24, Nanjing, Jiangsu 210009, China
| | - Nian Wang
- Key Laboratory of Drug Metabolism and Pharmacokinetics, State Key Laboratory of Natural Medicines, China Pharmaceutical University, Tongjiaxiang #24, Nanjing, Jiangsu 210009, China
| | - Yinxue Zhu
- School of Pharmacy, China Pharmaceutical University, Tongjiaxiang #24, Nanjing, Jiangsu 210009, China
| | - Ning Wan
- Key Laboratory of Drug Metabolism and Pharmacokinetics, State Key Laboratory of Natural Medicines, China Pharmaceutical University, Tongjiaxiang #24, Nanjing, Jiangsu 210009, China
| | - Yatao Shi
- School of Pharmacy, University of Wisconsin-Madison, 777 Highland Avenue, Madison, Wisconsin 53706, United States
| | - Guangji Wang
- Key Laboratory of Drug Metabolism and Pharmacokinetics, State Key Laboratory of Natural Medicines, China Pharmaceutical University, Tongjiaxiang #24, Nanjing, Jiangsu 210009, China
| | - Lingjun Li
- School of Pharmacy, University of Wisconsin-Madison, 777 Highland Avenue, Madison, Wisconsin 53706, United States
- Department of Chemistry, University of Wisconsin-Madison, 777 Highland Avenue, Madison, Wisconsin 53706, United States
| | - Haiping Hao
- School of Pharmacy, China Pharmaceutical University, Tongjiaxiang #24, Nanjing, Jiangsu 210009, China
- Key Laboratory of Drug Metabolism and Pharmacokinetics, State Key Laboratory of Natural Medicines, China Pharmaceutical University, Tongjiaxiang #24, Nanjing, Jiangsu 210009, China
| | - Hui Ye
- Key Laboratory of Drug Metabolism and Pharmacokinetics, State Key Laboratory of Natural Medicines, China Pharmaceutical University, Tongjiaxiang #24, Nanjing, Jiangsu 210009, China
| |
Collapse
|
17
|
Winter DL, Mastellone J, Kabir KMM, Wilkins MR, Donald WA. Separation of Isobaric Mono- and Dimethylated RGG-Repeat Peptides by Differential Ion Mobility-Mass Spectrometry. Anal Chem 2019; 91:11827-11833. [DOI: 10.1021/acs.analchem.9b02504] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Daniel L. Winter
- School of Biotechnology and Biomolecular Sciences, University of New South Wales, Sydney, New South Wales 2052, Australia
| | - Jordan Mastellone
- School of Chemistry, University of New South Wales, Sydney, New South Wales 2052, Australia
| | - K. M. Mohibul Kabir
- School of Chemistry, University of New South Wales, Sydney, New South Wales 2052, Australia
| | - Marc R. Wilkins
- School of Biotechnology and Biomolecular Sciences, University of New South Wales, Sydney, New South Wales 2052, Australia
| | - William A. Donald
- School of Chemistry, University of New South Wales, Sydney, New South Wales 2052, Australia
| |
Collapse
|
18
|
Winter DL, Wilkins MR, Donald WA. Differential Ion Mobility–Mass Spectrometry for Detailed Analysis of the Proteome. Trends Biotechnol 2019; 37:198-213. [DOI: 10.1016/j.tibtech.2018.07.018] [Citation(s) in RCA: 30] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2018] [Revised: 07/27/2018] [Accepted: 07/30/2018] [Indexed: 10/28/2022]
|
19
|
Affiliation(s)
- Clement
M. Potel
- Biomolecular
Mass Spectrometry and Proteomics, Bijvoet Center for Biomolecular
Research and Utrecht Institute for Pharmaceutical Sciences, Utrecht University, Padualaan 8, 3584
CH Utrecht, The Netherlands
- Netherlands
Proteomics Centre, Padualaan
8, 3584 CH Utrecht, The Netherlands
| | - Simone Lemeer
- Biomolecular
Mass Spectrometry and Proteomics, Bijvoet Center for Biomolecular
Research and Utrecht Institute for Pharmaceutical Sciences, Utrecht University, Padualaan 8, 3584
CH Utrecht, The Netherlands
- Netherlands
Proteomics Centre, Padualaan
8, 3584 CH Utrecht, The Netherlands
| | - Albert J. R. Heck
- Biomolecular
Mass Spectrometry and Proteomics, Bijvoet Center for Biomolecular
Research and Utrecht Institute for Pharmaceutical Sciences, Utrecht University, Padualaan 8, 3584
CH Utrecht, The Netherlands
- Netherlands
Proteomics Centre, Padualaan
8, 3584 CH Utrecht, The Netherlands
| |
Collapse
|
20
|
Chouinard CD, Nagy G, Webb IK, Shi T, Baker ES, Prost SA, Liu T, Ibrahim YM, Smith RD. Improved Sensitivity and Separations for Phosphopeptides using Online Liquid Chromotography Coupled with Structures for Lossless Ion Manipulations Ion Mobility-Mass Spectrometry. Anal Chem 2018; 90:10889-10896. [PMID: 30118596 PMCID: PMC6211290 DOI: 10.1021/acs.analchem.8b02397] [Citation(s) in RCA: 37] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Phosphoproteomics greatly augments proteomics and holds tremendous potential for insights into the modulation of biological systems for various disease states. However, numerous challenges hinder conventional methods in terms of measurement sensitivity, throughput, quantification, and capabilities for confident phosphopeptide and phosphosite identification. In this work, we report the first example of integrating structures for lossless ion manipulations ion mobility-mass spectrometry (SLIM IM-MS) with online reversed-phase liquid chromatography (LC) to evaluate its potential for addressing the aforementioned challenges. A mixture of 51 heavy-labeled phosphopeptides was analyzed with a SLIM IM module having integrated ion accumulation and long-path separation regions. The SLIM IM-MS provided limits of detection as low as 50-100 pM (50-100 amol/μL) for several phosphopeptides, with the potential for significant further improvements. In addition, conventionally problematic phosphopeptide isomers could be resolved following an 18 m SLIM IM separation. The 2-D LC-IM peak capacity was estimated as ∼9000 for a 90 min LC separation coupled to an 18 m SLIM IM separation, considerably higher than LC alone and providing a basis for both improved identification and quantification, with additional gains projected with the future use of longer path SLIM IM separations. Thus, LC-SLIM IM-MS offers great potential for improving the sensitivity, separation, and throughput of phosphoproteomics analyses.
Collapse
Affiliation(s)
- Christopher D. Chouinard
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, Washington 99352, United States
| | - Gabe Nagy
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, Washington 99352, United States
| | - Ian K. Webb
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, Washington 99352, United States
| | - Tujin Shi
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, Washington 99352, United States
| | - Erin S. Baker
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, Washington 99352, United States
| | - Spencer A. Prost
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, Washington 99352, United States
| | - Tao Liu
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, Washington 99352, United States
| | - Yehia M. Ibrahim
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, Washington 99352, United States
| | - Richard D. Smith
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, Washington 99352, United States
| |
Collapse
|
21
|
Pfammatter S, Bonneil E, McManus FP, Prasad S, Bailey DJ, Belford M, Dunyach JJ, Thibault P. A Novel Differential Ion Mobility Device Expands the Depth of Proteome Coverage and the Sensitivity of Multiplex Proteomic Measurements. Mol Cell Proteomics 2018; 17:2051-2067. [PMID: 30007914 DOI: 10.1074/mcp.tir118.000862] [Citation(s) in RCA: 93] [Impact Index Per Article: 15.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2018] [Revised: 07/11/2018] [Indexed: 01/17/2023] Open
Abstract
The depth of proteomic analyses is often limited by the overwhelming proportion of confounding background ions that compromise the identification and quantification of low abundance peptides. To alleviate these limitations, we present a new high field asymmetric waveform ion mobility spectrometry (FAIMS) interface that can be coupled to the Orbitrap Tribrid mass spectrometers. The interface provides several advantages over previous generations of FAIMS devices, including ease of operation, robustness, and high ion transmission. Replicate LC-FAIMS-MS/MS analyses (n = 100) of HEK293 protein digests showed stable ion current over extended time periods with uniform peptide identification on more than 10,000 distinct peptides. For complex tryptic digest analyses, the coupling of FAIMS to LC-MS/MS enabled a 30% gain in unique peptide identification compared with non-FAIMS experiments. Improvement in sensitivity facilitated the identification of low abundance peptides, and extended the limit of detection by almost an order of magnitude. The reduction in chimeric MS/MS spectra using FAIMS also improved the precision and the number of quantifiable peptides when using isobaric labeling with tandem mass tag (TMT) 10-plex reagent. We compared quantitative proteomic measurements for LC-MS/MS analyses performed using synchronous precursor selection (SPS) and LC-FAIMS-MS/MS to profile the temporal changes in protein abundance of HEK293 cells following heat shock for periods up to 9 h. FAIMS provided 2.5-fold increase in the number of quantifiable peptides compared with non-FAIMS experiments (30,848 peptides from 2,646 proteins for FAIMS versus 12,400 peptides from 1,229 proteins with SPS). Altogether, the enhancement in ion transmission and duty cycle of the new FAIMS interface extended the depth and comprehensiveness of proteomic analyses and improved the precision of quantitative measurements.
Collapse
Affiliation(s)
- Sibylle Pfammatter
- From the ‡Institute for Research in Immunology and Cancer, H3T 1J4, Québec, Canada.,§University of Montréal, Department of Chemistry, H3T 1J4, Québec, Canada
| | - Eric Bonneil
- From the ‡Institute for Research in Immunology and Cancer, H3T 1J4, Québec, Canada
| | - Francis P McManus
- From the ‡Institute for Research in Immunology and Cancer, H3T 1J4, Québec, Canada
| | - Satendra Prasad
- ¶Thermo Fisher Scientific, San Jose, California 95134, United States
| | - Derek J Bailey
- ¶Thermo Fisher Scientific, San Jose, California 95134, United States
| | - Michael Belford
- ¶Thermo Fisher Scientific, San Jose, California 95134, United States
| | | | - Pierre Thibault
- From the ‡Institute for Research in Immunology and Cancer, H3T 1J4, Québec, Canada; .,§University of Montréal, Department of Chemistry, H3T 1J4, Québec, Canada
| |
Collapse
|
22
|
Ma F, Sun R, Tremmel D, Sackett S, Odorico J, Li L. Large-Scale Differentiation and Site Specific Discrimination of Hydroxyproline Isomers by Electron Transfer/Higher-Energy Collision Dissociation (EThcD) Mass Spectrometry. Anal Chem 2018; 90:5857-5864. [PMID: 29624053 PMCID: PMC6481173 DOI: 10.1021/acs.analchem.8b00413] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
3- and 4-Hydroxyprolines (HyP) are regioisomers that play different roles in various species and organs. Despite their distinct functions inside cells, they are generally considered indistinguishable using mass spectrometry due to their identical masses. Here, we demonstrate, for the first time, that characteristic w ions can be produced by electron-transfer/higher energy collision dissociation (EThcD) dual fragmentation technique to confidently discriminate 3-HyP/4-HyP isomers. An integrated and high throughput strategy was developed which combined online LC separation with EThcD for large-scale differentiation of 3-HyP/4-HyP in complex samples. An automated algorithm was developed for charge state dependent characterization of 3-HyP/4-HyP isomers. Using this combined discrimination approach, we identified 108 3-HyP sites and 530 4-HyP sites from decellularized pancreas, allowing more than 5-fold increase of both 3-HyP and 4-HyP identifications compared to previous reports. This approach outperformed ETD and HCD in the analysis of HyP-containing peptides with unique capacity to generate w ions for HyP discrimination, improved fragmentation of precursor ions, as well as unambiguous localization of modifications. A high content of 3-HyP was observed in the C-terminal (GPP)n domain of human CO1A1, which was previously only identified in vertebrate fibrillar collagens from tendon. Unexpectedly, some unusual HyP sites at Xaa position in Gly-HyP-Ala, Gly-HyP-Val, Gly-HyP-Gln, Gly-HyP-Ser, and Gly-HyP-Arg were also confirmed to be 3-hydroxylated, whose functions and enzymes are yet to be discovered. Overall, this novel discrimination strategy can be readily implemented into de novo sequencing or other proteomic search engines.
Collapse
Affiliation(s)
- Fengfei Ma
- School of Pharmacy, University of Wisconsin-Madison, Madison, WI, 53705, USA
| | - Ruixiang Sun
- Institute of Computing Technology, Chinese Academy of Sciences, Beijing 100190, China
| | - Daniel Tremmel
- Division of Transplantation, Department of Surgery, School of Medicine and Public Health, University of Wisconsin-Madison, Madison, Wisconsin 53705, United States
| | - Sara Sackett
- Division of Transplantation, Department of Surgery, School of Medicine and Public Health, University of Wisconsin-Madison, Madison, Wisconsin 53705, United States
| | - Jon Odorico
- Division of Transplantation, Department of Surgery, School of Medicine and Public Health, University of Wisconsin-Madison, Madison, Wisconsin 53705, United States
| | - Lingjun Li
- School of Pharmacy, University of Wisconsin-Madison, Madison, WI, 53705, USA
- Department of Chemistry, University of Wisconsin-Madison, Madison, WI, 53706, USA
| |
Collapse
|
23
|
Tsai CW, Tipple CA, Yost RA. Integration of paper spray ionization high-field asymmetric waveform ion mobility spectrometry for forensic applications. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2018; 32:552-560. [PMID: 29380926 DOI: 10.1002/rcm.8068] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/25/2017] [Revised: 11/30/2017] [Accepted: 01/20/2018] [Indexed: 05/28/2023]
Abstract
RATIONALE Paper spray ionization (PSI) is an attractive ambient ionization source for mass spectrometry (MS) since it allows the combination of surface sampling and ionization. The minimal sample preparation inherent in this approach greatly reduces the time needed for analysis. However, the ions generated from interfering compounds in the sample and the paper substrate may interfere with the analyte ions. Therefore, the integration of PSI with high-field asymmetric ion mobility spectrometry (FAIMS) is of significant interest since it should reduce the background ions entering the mass analyzer without complicating the analysis or increasing analysis time. Here we demonstrate the integration of PSI with FAIMS/MS and its potential for analysis of samples of forensic interest. METHODS In this work, the parameters that can influence the integration, including sampling and ionization by paper spray, the FAIMS separation of analytes from each other and background interferences, and the length of time that a usable signal can be observed for explosives on paper, were evaluated with the integrated system. RESULTS In the negative ion analysis of 2,4,6-trinitrotoluene (TNT), pentaerythritol tetranitrate (PETN), octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX), and 1,3,5-trinitroperhydro-1,3,5-triazine (RDX), amounts as low as 1 ng on paper were readily observed. The successful positive ion separation of a set of illicit drugs including heroin, methamphetamine, and cocaine was also achieved. In addition, the positive ion analysis of the chemical warfare agent simulants dimethyl methylphosphonate (DMMP) and diisopropyl methylphosphonate (DIMP) was evaluated. CONCLUSIONS The integration of PSI-FAIMS/MS was demonstrated for the analyses of explosives in negative ion mode and for illicit drugs and CW simulants in positive mode. Paper background ions that could interfere with these analyses were separated by FAIMS. The compensation voltage of an ion obtained by FAIMS provided an additional identification parameter to be combined with the mass spectrum for each analyte.
Collapse
Affiliation(s)
- Chia-Wei Tsai
- Department of Chemistry, University of Florida, Gainesville, FL, USA
- Counterterrorism and Forensic Science Research Unit, Visiting Scientist Program, Federal Bureau of Investigation Laboratory Division, Quantico, VA, USA
| | - Christopher A Tipple
- Counterterrorism and Forensic Science Research Unit, Federal Bureau of Investigation Laboratory Division, Quantico, VA, USA
| | - Richard A Yost
- Department of Chemistry, University of Florida, Gainesville, FL, USA
| |
Collapse
|
24
|
Prabhakaran A, Hamid AM, Garimella SVB, Valenzuela BR, Ewing RG, Ibrahim YM, Smith RD. A Hybrid Constant and Oscillatory Field Ion Mobility Analyzer Using Structures for Lossless Ion Manipulations. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2018; 29:342-351. [PMID: 29235041 PMCID: PMC5815952 DOI: 10.1007/s13361-017-1841-6] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/31/2017] [Revised: 10/25/2017] [Accepted: 10/30/2017] [Indexed: 05/12/2023]
Abstract
Here we explore the combination of constant and oscillatory fields applied in a single device to affect the continuous separation and filtering of ions based on their mobilities. The device explored allows confining and manipulating ions utilizing a combination of radio frequency (rf), direct current (DC) fields, and traveling waves (TW) in a structures for lossless ion manipulations (SLIM) module. We have investigated theoretically and experimentally a concept for continuous filtering of ions based on their mobilities where ions are mobility separated and selected by passage through two regions, both of which incorporated combined TW and constant fields providing opposing forces on the ions. The SLIM module was composed of two surfaces with mirror-image arrays of electrodes and had two regions where the different TW and opposing DC fields could be applied. The filtering capabilities are determined by the applied DC gradient and the TW parameters, such as speed, amplitude, and the TW sequence (i.e., the duty cycle of the traveling wave). The effects of different parameters on the sensitivity and the ion mobility (IM) resolution of the device have been investigated. By appropriately choosing the DC gradient and TW parameters for the two sections, it is possible to transmit ions of a selected mobility while filtering out others of both higher and lower mobility. The novel device described here provides a basis for the targeted analysis of compounds based upon the continuous selection of ions according to their mobility and without the need for high electric fields or pulsed injection. Graphical abstract ᅟ.
Collapse
Affiliation(s)
- Aneesh Prabhakaran
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA, 99352, USA
| | - Ahmed M Hamid
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA, 99352, USA
| | - Sandilya V B Garimella
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA, 99352, USA
| | - Blandina R Valenzuela
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA, 99352, USA
| | - Robert G Ewing
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA, 99352, USA
| | - Yehia M Ibrahim
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA, 99352, USA.
| | - Richard D Smith
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA, 99352, USA.
| |
Collapse
|
25
|
Barran P. From Microsolvation to Cell Permeation: Novel Separation Science for Drug Discovery. ACS CENTRAL SCIENCE 2017; 3:158-160. [PMID: 28386592 PMCID: PMC5364446 DOI: 10.1021/acscentsci.7b00092] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
|
26
|
Dodds JN, May JC, McLean JA. Investigation of the Complete Suite of the Leucine and Isoleucine Isomers: Toward Prediction of Ion Mobility Separation Capabilities. Anal Chem 2016; 89:952-959. [PMID: 28029037 DOI: 10.1021/acs.analchem.6b04171] [Citation(s) in RCA: 63] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Abstract
In this study we investigated 11 isomers with the molecular formula C6H13NO2 (m/z 131) to ascertain the potential of utilizing drift tube ion mobility mass spectrometry to aid in the separation of isomeric mixtures. This study of small molecules provides a detailed examination of the application of uniform field ion mobility for a narrow scope of isomers with variations in both bond coordination and stereochemistry. For small molecules, it was observed that in general constitutional isomers are more readily separated by uniform field mobility in comparison to stereoisomers such as enantiomers or diastereomers. Diastereomers exhibited differences in their collision cross section (CCS), but were unresolvable in a mixture, whereas the enantiomers studied did not exhibit statistically different CCS values. A mathematical relationship relating the CCS to resolving power was developed in order to predict the required ion mobility resolving power needed to separate the various isomer classes. For the majority of isomers evaluated in this study, a uniform field-based resolving power of 100 was predicted to be sufficient to resolve over half (∼60%) of all hypothetical isomer pairs, including leucine and isoleucine, whereas their stereoisomers (d- and l-forms) are predicted to be significantly more challenging, if not impossible, to separate by conventional drift tube techniques.
Collapse
Affiliation(s)
- James N Dodds
- Department of Chemistry, Center for Innovative Technology, Vanderbilt Institute of Chemical Biology, Vanderbilt Institute for Integrative Biosystems Research and Education, Vanderbilt University , Nashville, Tennessee 37235, United States
| | - Jody C May
- Department of Chemistry, Center for Innovative Technology, Vanderbilt Institute of Chemical Biology, Vanderbilt Institute for Integrative Biosystems Research and Education, Vanderbilt University , Nashville, Tennessee 37235, United States
| | - John A McLean
- Department of Chemistry, Center for Innovative Technology, Vanderbilt Institute of Chemical Biology, Vanderbilt Institute for Integrative Biosystems Research and Education, Vanderbilt University , Nashville, Tennessee 37235, United States
| |
Collapse
|
27
|
Pfammatter S, Bonneil E, Thibault P. Improvement of Quantitative Measurements in Multiplex Proteomics Using High-Field Asymmetric Waveform Spectrometry. J Proteome Res 2016; 15:4653-4665. [PMID: 27723353 DOI: 10.1021/acs.jproteome.6b00745] [Citation(s) in RCA: 47] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
Quantitative proteomics using isobaric reagent tandem mass tags (TMT) or isobaric tags for relative and absolute quantitation (iTRAQ) provides a convenient approach to compare changes in protein abundance across multiple samples. However, the analysis of complex protein digests by isobaric labeling can be undermined by the relative large proportion of co-selected peptide ions that lead to distorted reporter ion ratios and affect the accuracy and precision of quantitative measurements. Here, we investigated the use of high-field asymmetric waveform ion mobility spectrometry (FAIMS) in proteomic experiments to reduce sample complexity and improve protein quantification using TMT isobaric labeling. LC-FAIMS-MS/MS analyses of human and yeast protein digests led to significant reductions in interfering ions, which increased the number of quantifiable peptides by up to 68% while significantly improving the accuracy of abundance measurements compared to that with conventional LC-MS/MS. The improvement in quantitative measurements using FAIMS is further demonstrated for the temporal profiling of protein abundance of HEK293 cells following heat shock treatment.
Collapse
Affiliation(s)
- Sibylle Pfammatter
- Institute for Research in Immunology and Cancer, ‡Department of Chemistry, Université de Montréal , C.P. 6128, Succursale centre-ville, Montréal, Québec H3C 3J7, Canada
| | - Eric Bonneil
- Institute for Research in Immunology and Cancer, ‡Department of Chemistry, Université de Montréal , C.P. 6128, Succursale centre-ville, Montréal, Québec H3C 3J7, Canada
| | - Pierre Thibault
- Institute for Research in Immunology and Cancer, ‡Department of Chemistry, Université de Montréal , C.P. 6128, Succursale centre-ville, Montréal, Québec H3C 3J7, Canada
| |
Collapse
|
28
|
Kaszycki JL, Bowman AP, Shvartsburg AA. Ion Mobility Separation of Peptide Isotopomers. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2016; 27:795-9. [PMID: 26944281 PMCID: PMC5030822 DOI: 10.1007/s13361-016-1367-3] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/21/2015] [Revised: 02/09/2016] [Accepted: 02/10/2016] [Indexed: 05/05/2023]
Abstract
Differential or field asymmetric waveform ion mobility spectrometry (FAIMS) operating at high electric fields fully resolves isotopic isomers for a peptide with labeled residues. The naturally present isotopes, alone and together with targeted labels, also cause spectral shifts that approximately add for multiple heavy atoms. Separation qualitatively depends on the gas composition. These findings may enable novel strategies in proteomic and metabolomic analyses using stable isotope labeling.
Collapse
Affiliation(s)
- Julia L Kaszycki
- Department of Chemistry, Wichita State University, 1845 Fairmount, Wichita, KS, 67260-0051, USA
| | - Andrew P Bowman
- Department of Chemistry, Wichita State University, 1845 Fairmount, Wichita, KS, 67260-0051, USA
| | - Alexandre A Shvartsburg
- Department of Chemistry, Wichita State University, 1845 Fairmount, Wichita, KS, 67260-0051, USA.
| |
Collapse
|
29
|
Glover MS, Dilger JM, Acton MD, Arnold RJ, Radivojac P, Clemmer DE. Examining the Influence of Phosphorylation on Peptide Ion Structure by Ion Mobility Spectrometry-Mass Spectrometry. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2016; 27:786-94. [PMID: 26860087 PMCID: PMC5750047 DOI: 10.1007/s13361-016-1343-y] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/14/2015] [Revised: 01/12/2016] [Accepted: 01/15/2016] [Indexed: 05/12/2023]
Abstract
Ion mobility spectrometry-mass spectrometry (IMS-MS) techniques are used to study the general effects of phosphorylation on peptide structure. Cross sections for a library of 66 singly phosphorylated peptide ions from 33 pairs of positional isomers, and unmodified analogues were measured. Intrinsic size parameters (ISPs) derived from these measurements yield calculated collision cross sections for 85% of these phosphopeptide sequences that are within ±2.5% of experimental values. The average ISP for the phosphoryl group (0.64 ± 0.05) suggests that in general this moiety forms intramolecular interactions with the neighboring residues and peptide backbone, resulting in relatively compact structures. We assess the capability of ion mobility to separate positional isomers (i.e., peptide sequences that differ only in the location of the modification) and find that more than half of the isomeric pairs have >1% difference in collision cross section. Phosphorylation is also found to influence populations of structures that differ in the cis/trans orientation of Xaa-Pro peptide bonds. Several sequences with phosphorylated Ser or Thr residues located N-terminally adjacent to Pro residues show fewer conformations compared to the unmodified sequences.
Collapse
Affiliation(s)
- Matthew S Glover
- Department of Chemistry, Indiana University, Bloomington, IN, 47405, USA
| | - Jonathan M Dilger
- Department of Chemistry, Indiana University, Bloomington, IN, 47405, USA
- Spectrum Warfare Systems Department, NSWC Crane Division, Crane, IN, 47522, USA
| | - Matthew D Acton
- Department of Chemistry, Indiana University, Bloomington, IN, 47405, USA
| | - Randy J Arnold
- Department of Chemistry, Indiana University, Bloomington, IN, 47405, USA
- AB SCIEX, Vaughan, ON, L4K 4V8, Canada
| | - Predrag Radivojac
- Department of Computer Science and Informatics, Indiana University, Bloomington, IN, 47405, USA
| | - David E Clemmer
- Department of Chemistry, Indiana University, Bloomington, IN, 47405, USA.
| |
Collapse
|
30
|
Cooper HJ. To What Extent is FAIMS Beneficial in the Analysis of Proteins? JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2016; 27:566-77. [PMID: 26843211 PMCID: PMC4792363 DOI: 10.1007/s13361-015-1326-4] [Citation(s) in RCA: 38] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/29/2015] [Revised: 12/08/2015] [Accepted: 12/10/2015] [Indexed: 05/11/2023]
Abstract
High field asymmetric waveform ion mobility spectrometry (FAIMS), also known as differential ion mobility spectrometry, is emerging as a tool for biomolecular analysis. In this article, the benefits and limitations of FAIMS for protein analysis are discussed. The principles and mechanisms of FAIMS separation of ions are described, and the differences between FAIMS and conventional ion mobility spectrometry are detailed. Protein analysis is considered from both the top-down (intact proteins) and the bottom-up (proteolytic peptides) perspective. The roles of FAIMS in the analysis of complex mixtures of multiple intact proteins and in the analysis of multiple conformers of a single protein are assessed. Similarly, the application of FAIMS in proteomics and targeted analysis of peptides are considered.
Collapse
Affiliation(s)
- Helen J Cooper
- School of Biosciences, University of Birmingham, Edgbaston, Birmingham, B15 2TT, UK.
| |
Collapse
|
31
|
Ollikainen E, Bonabi A, Nordman N, Jokinen V, Kotiaho T, Kostiainen R, Sikanen T. Rapid separation of phosphopeptides by microchip electrophoresis-electrospray ionization mass spectrometry. J Chromatogr A 2016; 1440:249-254. [PMID: 26931427 DOI: 10.1016/j.chroma.2016.02.063] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2015] [Revised: 02/19/2016] [Accepted: 02/22/2016] [Indexed: 01/12/2023]
Abstract
Protein phosphorylation is a significant biological process, but separation of phosphorylated peptide isomers is often challenging for many analytical techniques. We developed a microchip electrophoresis (MCE) method for rapid separation of phosphopeptides with on-chip electrospray ionization (ESI) facilitating online sample introduction to the mass spectrometer (MS). With the method, two monophosphorylated positional isomers of insulin receptor peptide (IR1A and IR1B) and a triply phosphorylated insulin receptor peptide (IR3), all with the same amino acid sequence, were separated from the nonphosphorylated peptide (IR0) in less than one minute. For efficient separation of the positional peptide isomers from each other derivatization with 9-fluorenylmethyl reagents (either chloroformate, Fmoc-Cl, or N-succinimidyl carbonate, Fmoc-OSu) was required before the analysis. The derivatization improved not only the separation of the monophosphorylated positional peptide isomers in MCE, but also identification of the phosphorylation site based on MS/MS.
Collapse
Affiliation(s)
- Elisa Ollikainen
- Division of Pharmaceutical Chemistry and Technology, Faculty of Pharmacy, University of Helsinki, Viikinkaari 5E, 00014 University of Helsinki, Finland
| | - Ashkan Bonabi
- Division of Pharmaceutical Chemistry and Technology, Faculty of Pharmacy, University of Helsinki, Viikinkaari 5E, 00014 University of Helsinki, Finland
| | - Nina Nordman
- Division of Pharmaceutical Chemistry and Technology, Faculty of Pharmacy, University of Helsinki, Viikinkaari 5E, 00014 University of Helsinki, Finland
| | - Ville Jokinen
- Department of Materials Science and Engineering, School of Chemical Technology, Aalto University, Finland, Micronova, Tietotie 3, 02150, Finland
| | - Tapio Kotiaho
- Division of Pharmaceutical Chemistry and Technology, Faculty of Pharmacy, University of Helsinki, Viikinkaari 5E, 00014 University of Helsinki, Finland; Laboratory of Analytical Chemistry, Department of Chemistry, University of Helsinki, A. I. Virtasen aukio 1, 00014 University of Helsinki, Finland
| | - Risto Kostiainen
- Division of Pharmaceutical Chemistry and Technology, Faculty of Pharmacy, University of Helsinki, Viikinkaari 5E, 00014 University of Helsinki, Finland
| | - Tiina Sikanen
- Division of Pharmaceutical Chemistry and Technology, Faculty of Pharmacy, University of Helsinki, Viikinkaari 5E, 00014 University of Helsinki, Finland.
| |
Collapse
|
32
|
Bonneil E, Pfammatter S, Thibault P. Enhancement of mass spectrometry performance for proteomic analyses using high-field asymmetric waveform ion mobility spectrometry (FAIMS). JOURNAL OF MASS SPECTROMETRY : JMS 2015; 50:1181-1195. [PMID: 26505763 DOI: 10.1002/jms.3646] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/18/2015] [Revised: 08/18/2015] [Accepted: 08/19/2015] [Indexed: 06/05/2023]
Abstract
Remarkable advances in mass spectrometry sensitivity and resolution have been accomplished over the past two decades to enhance the depth and coverage of proteome analyses. As these technological developments expanded the detection capability of mass spectrometers, they also revealed an increasing complexity of low abundance peptides, solvent clusters and sample contaminants that can confound protein identification. Separation techniques that are complementary and can be used in combination with liquid chromatography are often sought to improve mass spectrometry sensitivity for proteomics applications. In this context, high-field asymmetric waveform ion mobility spectrometry (FAIMS), a form of ion mobility that exploits ion separation at low and high electric fields, has shown significant advantages by focusing and separating multiply charged peptide ions from singly charged interferences. This paper examines the analytical benefits of FAIMS in proteomics to separate co-eluting peptide isomers and to enhance peptide detection and quantitative measurements of protein digests via native peptides (label-free) or isotopically labeled peptides from metabolic labeling or chemical tagging experiments.
Collapse
Affiliation(s)
- Eric Bonneil
- Institute for Research in Immunology and Cancer, Université de Montréal, C.P. 6128, Succursale centre-ville, Montréal, Québec, H3C 3J7, Canada
| | - Sibylle Pfammatter
- Institute for Research in Immunology and Cancer, Université de Montréal, C.P. 6128, Succursale centre-ville, Montréal, Québec, H3C 3J7, Canada
- Department of Chemistry, Université de Montréal, C.P. 6128, Succursale centre-ville, Montréal, Québec, H3C 3J7, Canada
| | - Pierre Thibault
- Institute for Research in Immunology and Cancer, Université de Montréal, C.P. 6128, Succursale centre-ville, Montréal, Québec, H3C 3J7, Canada
- Department of Chemistry, Université de Montréal, C.P. 6128, Succursale centre-ville, Montréal, Québec, H3C 3J7, Canada
| |
Collapse
|
33
|
Chicooree N, Unwin RD, Griffiths JR. The application of targeted mass spectrometry-based strategies to the detection and localization of post-translational modifications. MASS SPECTROMETRY REVIEWS 2015; 34:595-626. [PMID: 24737647 DOI: 10.1002/mas.21421] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/08/2013] [Accepted: 12/10/2013] [Indexed: 06/03/2023]
Abstract
This review describes some of the more interesting and imaginative ways in which mass spectrometry has been utilized to study a number of important post-translational modifications over the past two decades; from circa 1990 to 2013. A diverse range of modifications is covered, including citrullination, sulfation, hydroxylation and sumoylation. A summary of the biological role of each modification described, along with some brief mechanistic detail, is also included. Emphasis has been placed on strategies specifically aimed at detecting target modifications, as opposed to more serendipitous modification discovery approaches, which rely upon straightforward product ion scanning methods. The authors have intentionally excluded from this review both phosphorylation and glycosylation since these major modifications have been extensively reviewed elsewhere.
Collapse
Affiliation(s)
- Navin Chicooree
- CRUK Manchester Institute, University of Manchester, Wilmslow Road, Manchester, M20 4BX, UK
- School of Chemistry, University of Manchester, Brunswick Street, Manchester, M13 9SU, UK
| | - Richard D Unwin
- Centre for Advanced Discovery and Experimental Therapeutics (CADET), Central Manchester University Hospitals NHS Foundation Trust, Manchester Academic Health Sciences Centre, Manchester, M13 9WL, UK
- Institute of Human Development, Faculty of Medical and Human Sciences, University of Manchester, Manchester, UK
| | - John R Griffiths
- CRUK Manchester Institute, University of Manchester, Wilmslow Road, Manchester, M20 4BX, UK
| |
Collapse
|
34
|
Sarsby J, Griffiths RL, Race AM, Bunch J, Randall EC, Creese AJ, Cooper HJ. Liquid Extraction Surface Analysis Mass Spectrometry Coupled with Field Asymmetric Waveform Ion Mobility Spectrometry for Analysis of Intact Proteins from Biological Substrates. Anal Chem 2015; 87:6794-800. [DOI: 10.1021/acs.analchem.5b01151] [Citation(s) in RCA: 62] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Affiliation(s)
- Joscelyn Sarsby
- School
of Biosciences, University of Birmingham, Edgbaston, Birmingham B15 2TT, United Kingdom
| | - Rian L. Griffiths
- School
of Biosciences, University of Birmingham, Edgbaston, Birmingham B15 2TT, United Kingdom
| | - Alan M. Race
- National Physical
Laboratory, Hampton Road, Teddington, Middlesex TW11 0LW, United Kingdom
| | - Josephine Bunch
- National Physical
Laboratory, Hampton Road, Teddington, Middlesex TW11 0LW, United Kingdom
- School
of Pharmacy, University of Nottingham, University Park, Nottingham NG7 2RD, United Kingdom
| | - Elizabeth C. Randall
- School
of Biosciences, University of Birmingham, Edgbaston, Birmingham B15 2TT, United Kingdom
| | - Andrew J. Creese
- School
of Biosciences, University of Birmingham, Edgbaston, Birmingham B15 2TT, United Kingdom
| | - Helen J. Cooper
- School
of Biosciences, University of Birmingham, Edgbaston, Birmingham B15 2TT, United Kingdom
| |
Collapse
|
35
|
Buchberger A, Yu Q, Li L. Advances in Mass Spectrometric Tools for Probing Neuropeptides. ANNUAL REVIEW OF ANALYTICAL CHEMISTRY (PALO ALTO, CALIF.) 2015; 8:485-509. [PMID: 26070718 PMCID: PMC6314846 DOI: 10.1146/annurev-anchem-071114-040210] [Citation(s) in RCA: 49] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/12/2023]
Abstract
Neuropeptides are important mediators in the functionality of the brain and other neurological organs. Because neuropeptides exist in a wide range of concentrations, appropriate characterization methods are needed to provide dynamic, chemical, and spatial information. Mass spectrometry and compatible tools have been a popular choice in analyzing neuropeptides. There have been several advances and challenges, both of which are the focus of this review. Discussions range from sample collection to bioinformatic tools, although avenues such as quantitation and imaging are included. Further development of the presented methods for neuropeptidomic mass spectrometric analysis is inevitable, which will lead to a further understanding of the complex interplay of neuropeptides and other signaling molecules in the nervous system.
Collapse
Affiliation(s)
- Amanda Buchberger
- Department of Chemistry, University of Wisconsin-Madison, Madison, Wisconsin 53706-1322;
| | - Qing Yu
- School of Pharmacy, University of Wisconsin-Madison, Madison, Wisconsin 53705-2222;
| | - Lingjun Li
- Department of Chemistry, University of Wisconsin-Madison, Madison, Wisconsin 53706-1322;
- School of Pharmacy, University of Wisconsin-Madison, Madison, Wisconsin 53705-2222;
| |
Collapse
|
36
|
Webb IK, Garimella SVB, Tolmachev AV, Chen TC, Zhang X, Cox JT, Norheim R, Prost S, LaMarche B, Anderson GA, Ibrahim YM, Smith RD. Mobility-resolved ion selection in uniform drift field ion mobility spectrometry/mass spectrometry: dynamic switching in structures for lossless ion manipulations. Anal Chem 2014; 86:9632-7. [PMID: 25222548 PMCID: PMC4188271 DOI: 10.1021/ac502139e] [Citation(s) in RCA: 40] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2014] [Accepted: 09/15/2014] [Indexed: 11/29/2022]
Abstract
A Structures for Lossless Ion Manipulations (SLIM) module that allows ion mobility separations and the switching of ions between alternative drift paths is described. The SLIM switch component has a "Tee" configuration and allows the efficient switching of ions between a linear path and a 90-degree bend. By controlling switching times, ions can be efficiently directed to an alternative channel as a function of their mobilities. In the initial evaluation the switch is used in a static mode and shown compatible with high performance ion mobility separations at 4 Torr. In the dynamic mode, we show that mobility-selected ions can be switched into the alternative channel, and that various ion species can be independently selected based on their mobilities for time-of-flight mass spectrometer (TOF MS) IMS detection and mass analysis. This development also provides the basis of, for example, the selection of specific mobilities for storage and accumulation, and the key component of modules for the assembly of SLIM devices enabling much more complex sequences of ion manipulations.
Collapse
Affiliation(s)
- Ian K. Webb
- Biological
Sciences Division
and Environmental Molecular Sciences Laboratory, Pacific Northwest National Laboratory, 3335 Innovation Avenue (K8-98), P.O. Box 999, Richland, Washington 99352, United States
| | - Sandilya V. B. Garimella
- Biological
Sciences Division
and Environmental Molecular Sciences Laboratory, Pacific Northwest National Laboratory, 3335 Innovation Avenue (K8-98), P.O. Box 999, Richland, Washington 99352, United States
| | - Aleksey V. Tolmachev
- Biological
Sciences Division
and Environmental Molecular Sciences Laboratory, Pacific Northwest National Laboratory, 3335 Innovation Avenue (K8-98), P.O. Box 999, Richland, Washington 99352, United States
| | - Tsung-Chi Chen
- Biological
Sciences Division
and Environmental Molecular Sciences Laboratory, Pacific Northwest National Laboratory, 3335 Innovation Avenue (K8-98), P.O. Box 999, Richland, Washington 99352, United States
| | - Xinyu Zhang
- Biological
Sciences Division
and Environmental Molecular Sciences Laboratory, Pacific Northwest National Laboratory, 3335 Innovation Avenue (K8-98), P.O. Box 999, Richland, Washington 99352, United States
| | - Jonathan T. Cox
- Biological
Sciences Division
and Environmental Molecular Sciences Laboratory, Pacific Northwest National Laboratory, 3335 Innovation Avenue (K8-98), P.O. Box 999, Richland, Washington 99352, United States
| | - Randolph
V. Norheim
- Biological
Sciences Division
and Environmental Molecular Sciences Laboratory, Pacific Northwest National Laboratory, 3335 Innovation Avenue (K8-98), P.O. Box 999, Richland, Washington 99352, United States
| | - Spencer
A. Prost
- Biological
Sciences Division
and Environmental Molecular Sciences Laboratory, Pacific Northwest National Laboratory, 3335 Innovation Avenue (K8-98), P.O. Box 999, Richland, Washington 99352, United States
| | - Brian LaMarche
- Biological
Sciences Division
and Environmental Molecular Sciences Laboratory, Pacific Northwest National Laboratory, 3335 Innovation Avenue (K8-98), P.O. Box 999, Richland, Washington 99352, United States
| | - Gordon A. Anderson
- Biological
Sciences Division
and Environmental Molecular Sciences Laboratory, Pacific Northwest National Laboratory, 3335 Innovation Avenue (K8-98), P.O. Box 999, Richland, Washington 99352, United States
| | - Yehia M. Ibrahim
- Biological
Sciences Division
and Environmental Molecular Sciences Laboratory, Pacific Northwest National Laboratory, 3335 Innovation Avenue (K8-98), P.O. Box 999, Richland, Washington 99352, United States
| | - Richard D. Smith
- Biological
Sciences Division
and Environmental Molecular Sciences Laboratory, Pacific Northwest National Laboratory, 3335 Innovation Avenue (K8-98), P.O. Box 999, Richland, Washington 99352, United States
| |
Collapse
|
37
|
Webb IK, Garimella SVB, Tolmachev AV, Chen TC, Zhang X, Norheim RV, Prost SA, LaMarche B, Anderson GA, Ibrahim YM, Smith RD. Experimental evaluation and optimization of structures for lossless ion manipulations for ion mobility spectrometry with time-of-flight mass spectrometry. Anal Chem 2014; 86:9169-76. [PMID: 25152066 PMCID: PMC4165449 DOI: 10.1021/ac502055e] [Citation(s) in RCA: 77] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2014] [Accepted: 08/23/2014] [Indexed: 02/02/2023]
Abstract
We report on the performance of structures for lossless ion manipulation (SLIM) as a means for transmitting ions and performing ion mobility separations (IMS). Ions were successfully transferred from an electrospray ionization (ESI) source to the TOF MS analyzer by means of a linear SLIM, demonstrating lossless ion transmission and an alternative arrangement including a 90° turn. First, the linear geometry was optimized for radial confinement by tuning RF on the central "rung" electrodes and potentials on the DC-only guard electrodes. Selecting an appropriate DC guard bias (2-6 V) and RF amplitude (≥160 V(p-p) at 750 kHz) resulted in the greatest ion intensities. Close to ideal IMS resolving power was maintained over a significant range of applied voltages. Second, the 90° turn was optimized for radial confinement by tuning RF on the rung electrodes and DC on the guard electrodes. However, both resolving power and ion transmission showed a dependence on these voltages, and the best conditions for both were >300 V(p-p) RF (685 kHz) and 7-11 V guard DC bias. Both geometries provide IMS resolving powers at the theoretical limit (R ~ 58), showing that degraded resolution from a "racetrack" effect from turning around a corner can be successfully avoided, and the capability also was maintained for essentially lossless ion transmission.
Collapse
Affiliation(s)
- Ian K. Webb
- Biological
Sciences Division and Environmental Molecular
Sciences Laboratory, Pacific Northwest National
Laboratory, 3335 Innovation
Ave. (K8-98), P.O. Box 999, Richland, Washington 99352, United States
| | - Sandilya V. B. Garimella
- Biological
Sciences Division and Environmental Molecular
Sciences Laboratory, Pacific Northwest National
Laboratory, 3335 Innovation
Ave. (K8-98), P.O. Box 999, Richland, Washington 99352, United States
| | - Aleksey V. Tolmachev
- Biological
Sciences Division and Environmental Molecular
Sciences Laboratory, Pacific Northwest National
Laboratory, 3335 Innovation
Ave. (K8-98), P.O. Box 999, Richland, Washington 99352, United States
| | - Tsung-Chi Chen
- Biological
Sciences Division and Environmental Molecular
Sciences Laboratory, Pacific Northwest National
Laboratory, 3335 Innovation
Ave. (K8-98), P.O. Box 999, Richland, Washington 99352, United States
| | - Xinyu Zhang
- Biological
Sciences Division and Environmental Molecular
Sciences Laboratory, Pacific Northwest National
Laboratory, 3335 Innovation
Ave. (K8-98), P.O. Box 999, Richland, Washington 99352, United States
| | - Randolph V. Norheim
- Biological
Sciences Division and Environmental Molecular
Sciences Laboratory, Pacific Northwest National
Laboratory, 3335 Innovation
Ave. (K8-98), P.O. Box 999, Richland, Washington 99352, United States
| | - Spencer A. Prost
- Biological
Sciences Division and Environmental Molecular
Sciences Laboratory, Pacific Northwest National
Laboratory, 3335 Innovation
Ave. (K8-98), P.O. Box 999, Richland, Washington 99352, United States
| | - Brian LaMarche
- Biological
Sciences Division and Environmental Molecular
Sciences Laboratory, Pacific Northwest National
Laboratory, 3335 Innovation
Ave. (K8-98), P.O. Box 999, Richland, Washington 99352, United States
| | - Gordon A. Anderson
- Biological
Sciences Division and Environmental Molecular
Sciences Laboratory, Pacific Northwest National
Laboratory, 3335 Innovation
Ave. (K8-98), P.O. Box 999, Richland, Washington 99352, United States
| | - Yehia M. Ibrahim
- Biological
Sciences Division and Environmental Molecular
Sciences Laboratory, Pacific Northwest National
Laboratory, 3335 Innovation
Ave. (K8-98), P.O. Box 999, Richland, Washington 99352, United States
| | - Richard D. Smith
- Biological
Sciences Division and Environmental Molecular
Sciences Laboratory, Pacific Northwest National
Laboratory, 3335 Innovation
Ave. (K8-98), P.O. Box 999, Richland, Washington 99352, United States
| |
Collapse
|
38
|
Auerbach D, Aspenleiter J, Volmer DA. Description of gas-phase ion/neutral interactions in differential ion mobility spectrometry: CV prediction using calibration runs. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2014; 25:1610-1621. [PMID: 24927778 DOI: 10.1007/s13361-014-0934-8] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/31/2014] [Revised: 05/12/2014] [Accepted: 05/12/2014] [Indexed: 06/03/2023]
Abstract
Differential ion mobility spectrometry (DMS) coupled to mass spectrometry is increasingly used in both quantitative analyses of biological samples and as a means of removing background interferences for enhanced selectivity and improved quality of mass spectra. However, DMS separation efficiency using dry inert gases often lacks the required selectivity to achieve baseline separation. Polar gas-phase modifiers such as alcohols are therefore frequently employed to improve selectivity via clustering/declustering processes. The choice of an optimal modifier currently relies on trial and error experiments, making method development a tedious activity. It was the goal of this study to establish a means of CV prediction for compounds using a homologous series of alcohols as gas-phase modifiers. This prediction was based on linear regression of compensation voltages of two calibration runs for the alcohols with the lowest and the highest molecular weights and readily available descriptors such as proton affinity and gas phase acidity of the modifier molecules. All experiments were performed on a commercial quadrupole linear ion trap mass spectrometer equipped with a DMS device between electrospray ionization source and entrance quadrupole lens. We evaluated our approach using a homologous series of 4-alkylbenzoic acids and a selection of 23 small molecules of high chemical diversity. Predicted CV values typically deviated from the experimentally determined values by less than 0.5 V. Several test compounds changed their ion mobility behavior for the investigated gas phase modifiers (e.g., from type B to type A) and thus could thus not be evaluated.
Collapse
Affiliation(s)
- David Auerbach
- Institute of Bioanalytical Chemistry, Saarland University, Saarbrücken, Germany
| | | | | |
Collapse
|
39
|
Li Z, Dilger JM, Pejaver V, Smiley D, Arnold RJ, Mooney SD, Mukhopadhyay S, Radivojac P, Clemmer DE. Intrinsic Size Parameters for Palmitoylated and Carboxyamidomethylated Peptides. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY 2014; 368:6-14. [PMID: 26023288 PMCID: PMC4443490 DOI: 10.1016/j.ijms.2014.04.009] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/17/2023]
Abstract
Cross sections for 61 palmitoylated peptides and 73 cysteine-unmodified peptides are determined and used together with a previously obtained tryptic peptide library to derive a set of intrinsic size parameters (ISPs) for the palmitoyl (Pal) group (1.26 ± 0.04), carboxyamidomethyl (Am) group (0.92 ± 0.04), and the 20 amino acid residues to assess the influence of Pal- and Am-modification on cysteine and other amino acid residues. These values highlight the influence of the intrinsic hydrophobic and hydrophilic nature of these modifications on the overall cross sections. As a part of this analysis, we find that ISPs derived from a database of a modifier on one amino acid residue (CysPal) can be applied on the same modification group on different amino acid residues (SerPal and TyrPal). Using these ISP values, we are able to calculate peptide cross sections to within ± 2% of experimental values for 83% of Pal-modified peptide ions and 63% of Am-modified peptide ions. We propose that modification groups should be treated as individual contribution factors, instead of treating the combination of the particular group and the amino acid residue they are on as a whole when considering their effects on the peptide ion mobility features.
Collapse
Affiliation(s)
- Zhiyu Li
- Department of Chemistry, Indiana University, Bloomington, IN 47405
| | | | - Vikas Pejaver
- Department of Computer Science and Informatics, Indiana University, Bloomington, IN 47405
| | - David Smiley
- Department of Chemistry, Indiana University, Bloomington, IN 47405
| | - Randy J Arnold
- Department of Chemistry, Indiana University, Bloomington, IN 47405
| | - Sean D Mooney
- Buck Institute for Research on Aging, Novato, CA 94945
| | | | - Predrag Radivojac
- Department of Computer Science and Informatics, Indiana University, Bloomington, IN 47405
| | - David E Clemmer
- Department of Chemistry, Indiana University, Bloomington, IN 47405
| |
Collapse
|
40
|
Lanucara F, Fornarini S, Eyers CE, Crestoni ME. Probing the exposure of the phosphate group in modified amino acids and peptides by ion-molecule reactions with triethoxyborane in Fourier transform ion cyclotron resonance mass spectrometry. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2014; 28:1107-1116. [PMID: 24711274 DOI: 10.1002/rcm.6884] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/25/2014] [Revised: 02/27/2014] [Accepted: 02/27/2014] [Indexed: 06/03/2023]
Abstract
RATIONALE Intramolecular hydrogen bonds between a phosphate group and charged residues play a crucial role in the chemistry of phosphorylated peptides, driving the species to specific conformations and affecting the exposure of the phosphate moiety. The nature and extent of these interactions can be investigated by measuring the reactivity of phosphate groups toward selected substrates in the gas phase. METHODS We used Fourier Transform Ion Cyclotron Resonance (FT-ICR) mass spectrometry (MS) to perform a systematic study on the gas-phase ionic reactivity of phosphorylated amino acids and peptides with triethoxyborane (TEB). Ions of interest were generated by electrospray ionization (ESI), isolated in the cell of the FT-ICR mass spectrometer, and allowed to react with a stationary pressure of TEB. The temporal evolution of the reaction was monitored and thermal rate constants were derived. The structure of the ionic products was confirmed by Collision-Induced Dissociation (CID) tandem mass spectrometry (MS/MS). RESULTS TEB was found to react with the phosphate of protonated phosphorylated amino acids and peptides by an addition-elimination pathway. The kinetic efficiency of the reaction showed a positive correlation with the charge state of the reagent ion, suggesting the existence of charge-state-dependent exposure of the phosphate groups towards the incoming neutral during the reaction. Isomeric phosphorylated peptides, only differing for the position of the modified serine residue, showed markedly different kinetic efficiencies. CONCLUSIONS The ability of a phosphorylated species to react with TEB depends on the ease of access to the phosphate moiety in the corresponding gaseous ion. Measuring the kinetic efficiency of such reactions can represent a valuable tool to explore the accessibility of phosphate groups in biomolecules.
Collapse
Affiliation(s)
- Francesco Lanucara
- Manchester Institute of Biotechnology, School of Chemistry, University of Manchester, Manchester, M1 7DN, UK; Institute of Integrative Biology, University of Liverpool, Liverpool, L69 7ZB, UK
| | | | | | | |
Collapse
|
41
|
Shvartsburg AA, Ibrahim YM, Smith RD. Differential ion mobility separations in up to 100% helium using microchips. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2014; 25:480-9. [PMID: 24402673 PMCID: PMC4031910 DOI: 10.1007/s13361-013-0797-4] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/29/2013] [Revised: 11/26/2013] [Accepted: 11/27/2013] [Indexed: 05/11/2023]
Abstract
The performance of differential IMS (FAIMS) analyzers is much enhanced by gases comprising He, especially He/N2 mixtures. However, electrical breakdown has limited the He fraction to ~50%-75%, depending on the field strength. By the Paschen law, the threshold field for breakdown increases at shorter distances. This allows FAIMS using chips with microscopic channels to utilize much stronger field intensities (E) than "full-size" analyzers with wider gaps. Here we show that those chips can employ higher He fractions up to 100%. Use of He-rich gases improves the resolution and resolution/sensitivity balance substantially, although less than for full-size analyzers. The optimum He fraction is ~80%, in line with first-principles theory. Hence, one can now measure the dependences of ion mobility on E in pure He, where ion-molecule cross section calculations are much more tractable than in other gases that form deeper and more complex interaction potentials. This capability may facilitate quantitative modeling of high-field ion mobility behavior and, thus, FAIMS separation properties, which would enable a priori extraction of structural information about the ions.
Collapse
Affiliation(s)
- Alexandre A Shvartsburg
- Biological Sciences Division, Pacific Northwest National Laboratory, P.O. Box 999, Richland, WA, 99352, USA,
| | | | | |
Collapse
|
42
|
Kailemia MJ, Park M, Kaplan DA, Venot A, Boons GJ, Li L, Linhardt RJ, Amster IJ. High-field asymmetric-waveform ion mobility spectrometry and electron detachment dissociation of isobaric mixtures of glycosaminoglycans. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2014; 25:258-68. [PMID: 24254578 PMCID: PMC3946938 DOI: 10.1007/s13361-013-0771-1] [Citation(s) in RCA: 49] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/02/2013] [Revised: 10/09/2013] [Accepted: 10/09/2013] [Indexed: 05/20/2023]
Abstract
High-field asymmetric waveform ion mobility spectrometry (FAIMS) is shown to be capable of resolving isomeric and isobaric glycosaminoglycan negative ions and to have great utility for the analysis of this class of molecules when combined with Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) and tandem mass spectrometry. Electron detachment dissociation (EDD) and other ion activation methods for tandem mass spectrometry can be used to determine the sites of labile sulfate modifications and for assigning the stereochemistry of hexuronic acid residues of glycosaminoglycans (GAGs). However, mixtures with overlapping mass-to-charge values present a challenge, as their precursor species cannot be resolved by a mass analyzer prior to ion activation. FAIMS is shown to resolve two types of mass-to-charge overlaps. A mixture of chondroitin sulfate A (CSA) oligomers with 4-10 saccharides units produces ions of a single mass-to-charge by electrospray ionization, as the charge state increases in direct proportion to the degree of polymerization for these sulfated carbohydrates. FAIMS is shown to resolve the overlapping charge. A more challenging type of mass-to-charge overlap occurs for mixtures of diastereomers. FAIMS is shown to separate two sets of epimeric GAG tetramers. For the epimer pairs, the complexity of the separation is reduced when the reducing end is alkylated, suggesting that anomers are also resolved by FAIMS. The resolved components were activated by EDD and the fragment ions were analyzed by FTICR-MS. The resulting tandem mass spectra were able to distinguish the two epimers from each other.
Collapse
Affiliation(s)
| | | | | | - Andre Venot
- Complex Carbohydrate Research Center, University of Georgia, Athens, GA, USA
| | - Geert-Jan Boons
- Complex Carbohydrate Research Center, University of Georgia, Athens, GA, USA
| | - Lingyun Li
- Department of Chemistry and Chemical Biology, Chemical and Biological Engineering, and Biology, Rensselaer Polytechnic Institute, Troy, NY 12180
| | - Robert J. Linhardt
- Department of Chemistry and Chemical Biology, Chemical and Biological Engineering, and Biology, Rensselaer Polytechnic Institute, Troy, NY 12180
| | - I. Jonathan Amster
- Department of Chemistry, University of Georgia, Athens, GA 30602
- Address for correspondence: Department of Chemistry, University of Georgia, Athens, GA 30602, Phone: (706) 542-2001, Fax: (706) 542-9454,
| |
Collapse
|
43
|
Mui W, Thomas DA, Downard AJ, Beauchamp JL, Seinfeld JH, Flagan RC. Ion Mobility-Mass Spectrometry with a Radial Opposed Migration Ion and Aerosol Classifier (ROMIAC). Anal Chem 2013; 85:6319-26. [DOI: 10.1021/ac400580u] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Wilton Mui
- Division of Engineering
and
Applied Science, California Institute of Technology, Pasadena, California 91125, United States
| | - Daniel A. Thomas
- Division of Chemistry and Chemical
Engineering, California Institute of Technology, Pasadena, California 91125, United States
| | - Andrew J. Downard
- Division of Chemistry and Chemical
Engineering, California Institute of Technology, Pasadena, California 91125, United States
| | - Jesse L. Beauchamp
- Division of Chemistry and Chemical
Engineering, California Institute of Technology, Pasadena, California 91125, United States
| | - John H. Seinfeld
- Division of Engineering
and
Applied Science, California Institute of Technology, Pasadena, California 91125, United States
- Division of Chemistry and Chemical
Engineering, California Institute of Technology, Pasadena, California 91125, United States
| | - Richard C. Flagan
- Division of Engineering
and
Applied Science, California Institute of Technology, Pasadena, California 91125, United States
- Division of Chemistry and Chemical
Engineering, California Institute of Technology, Pasadena, California 91125, United States
| |
Collapse
|
44
|
Swearingen KE, Moritz RL. High-field asymmetric waveform ion mobility spectrometry for mass spectrometry-based proteomics. Expert Rev Proteomics 2013. [PMID: 23194268 DOI: 10.1586/epr.12.50] [Citation(s) in RCA: 68] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
High-field asymmetric waveform ion mobility spectrometry (FAIMS) is an atmospheric pressure ion mobility technique that separates gas-phase ions by their behavior in strong and weak electric fields. FAIMS is easily interfaced with electrospray ionization and has been implemented as an additional separation mode between liquid chromatography (LC) and mass spectrometry (MS) in proteomic studies. FAIMS separation is orthogonal to both LC and MS and is used as a means of on-line fractionation to improve the detection of peptides in complex samples. FAIMS improves dynamic range and concomitantly the detection limits of ions by filtering out chemical noise. FAIMS can also be used to remove interfering ion species and to select peptide charge states optimal for identification by tandem MS. Here, the authors review recent developments in LC-FAIMS-MS and its application to MS-based proteomics.
Collapse
|
45
|
Zhang Y, Fonslow BR, Shan B, Baek MC, Yates JR. Protein analysis by shotgun/bottom-up proteomics. Chem Rev 2013; 113:2343-94. [PMID: 23438204 PMCID: PMC3751594 DOI: 10.1021/cr3003533] [Citation(s) in RCA: 986] [Impact Index Per Article: 89.6] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Affiliation(s)
- Yaoyang Zhang
- Department of Chemical Physiology, The Scripps Research Institute, La Jolla, CA 92037, USA
| | - Bryan R. Fonslow
- Department of Chemical Physiology, The Scripps Research Institute, La Jolla, CA 92037, USA
| | - Bing Shan
- Department of Chemical Physiology, The Scripps Research Institute, La Jolla, CA 92037, USA
| | - Moon-Chang Baek
- Department of Chemical Physiology, The Scripps Research Institute, La Jolla, CA 92037, USA
- Department of Molecular Medicine, Cell and Matrix Biology Research Institute, School of Medicine, Kyungpook National University, Daegu 700-422, Republic of Korea
| | - John R. Yates
- Department of Chemical Physiology, The Scripps Research Institute, La Jolla, CA 92037, USA
| |
Collapse
|
46
|
Creese AJ, Shimwell NJ, Larkins KPB, Heath JK, Cooper HJ. Probing the complementarity of FAIMS and strong cation exchange chromatography in shotgun proteomics. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2013; 24:431-43. [PMID: 23400772 PMCID: PMC3586169 DOI: 10.1007/s13361-012-0544-2] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/14/2012] [Revised: 11/08/2012] [Accepted: 11/11/2012] [Indexed: 05/25/2023]
Abstract
High field asymmetric waveform ion mobility spectrometry (FAIMS), also known as differential ion mobility spectrometry, coupled with liquid chromatography tandem mass spectrometry (LC-MS/MS) offers benefits for the analysis of complex proteomics samples. Advantages include increased dynamic range, increased signal-to-noise, and reduced interference from ions of similar m/z. FAIMS also separates isomers and positional variants. An alternative, and more established, method of reducing sample complexity is prefractionation by use of strong cation exchange chromatography. Here, we have compared SCX-LC-MS/MS with LC-FAIMS-MS/MS for the identification of peptides and proteins from whole cell lysates from the breast carcinoma SUM52 cell line. Two FAIMS approaches are considered: (1) multiple compensation voltages within a single LC-MS/MS analysis (internal stepping) and (2) repeat LC-MS/MS analyses at different and fixed compensation voltages (external stepping). We also consider the consequence of the fragmentation method (electron transfer dissociation or collision-induced dissociation) on the workflow performance. The external stepping approach resulted in a greater number of protein and peptide identifications than the internal stepping approach for both ETD and CID MS/MS, suggesting that this should be the method of choice for FAIMS proteomics experiments. The overlap in protein identifications from the SCX method and the external FAIMS method was ~25% for both ETD and CID, and for peptides was less than 20%. The lack of overlap between FAIMS and SCX highlights the complementarity of the two techniques. Charge state analysis of the peptide assignments showed that the FAIMS approach identified a much greater proportion of triply-charged ions.
Collapse
Affiliation(s)
- Andrew J. Creese
- School of Biosciences, College of Life and Environmental Sciences, University of Birmingham, Birmingham, B15 2TT UK
| | - Neil J. Shimwell
- School of Biosciences, College of Life and Environmental Sciences, University of Birmingham, Birmingham, B15 2TT UK
- Present Address: School of Cancer Sciences, College of Medical and Dental Sciences, University of Birmingham, Birmingham, B15 2TT UK
| | - Katherine P. B. Larkins
- School of Biosciences, College of Life and Environmental Sciences, University of Birmingham, Birmingham, B15 2TT UK
| | - John K. Heath
- School of Biosciences, College of Life and Environmental Sciences, University of Birmingham, Birmingham, B15 2TT UK
| | - Helen J. Cooper
- School of Biosciences, College of Life and Environmental Sciences, University of Birmingham, Birmingham, B15 2TT UK
| |
Collapse
|
47
|
Stedwell CN, Patrick AL, Gulyuz K, Polfer NC. Screening for Phosphorylated and Nonphosphorylated Peptides by Infrared Photodissociation Spectroscopy. Anal Chem 2012; 84:9907-12. [DOI: 10.1021/ac3023058] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Affiliation(s)
- Corey N. Stedwell
- Department of Chemistry, University of Florida, Post Office Box 117200, Gainesville, Florida
32611, United States
| | - Amanda L. Patrick
- Department of Chemistry, University of Florida, Post Office Box 117200, Gainesville, Florida
32611, United States
| | - Kerim Gulyuz
- Department of Chemistry, University of Florida, Post Office Box 117200, Gainesville, Florida
32611, United States
| | - Nicolas C. Polfer
- Department of Chemistry, University of Florida, Post Office Box 117200, Gainesville, Florida
32611, United States
| |
Collapse
|
48
|
High-field asymmetric waveform ion mobility spectrometry with solvent vapor addition: a potential greener bioanalytical technique. Bioanalysis 2012; 4:1363-75. [PMID: 22720654 DOI: 10.4155/bio.12.110] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023] Open
Abstract
Green chemistry is a way to avoid threats to human health and the environment in chemical processes, including analytical methodology. According to the 12 principles provided by ACS Green Chemistry Institute, first described by Anastas and Warner, prevention of waste generation should be first considered as an alternative to ways of treating waste. Therefore, analytical techniques that may reduce solvent waste are of great interest towards greener analysis. High-field asymmetric waveform ion mobility spectrometry (FAIMS) utilizes electrical fields to achieve separation, post an ionization source, and could provide an alternative method for separation and reduce solvent use in comparison with traditional HPLC methodologies. In this article, the operational principles and developments of FAIMS will be discussed, including the advantages of adding solvent vapor to the carrier gas. In addition, applications and challenges of implementing FAIMS technology will also be discussed.
Collapse
|
49
|
Chawner R, McCullough B, Giles K, Barran PE, Gaskell SJ, Eyers CE. QconCAT standard for calibration of ion mobility-mass spectrometry systems. J Proteome Res 2012; 11:5564-72. [PMID: 22985290 DOI: 10.1021/pr3005327] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
Ion mobility-mass spectrometry (IM-MS) is a useful technique for determining information about analyte ion conformation in addition to mass/charge ratio. The physical principles that govern the mobility of an ion through a gas in the presence of a uniform electric field are well understood, enabling rotationally averaged collision cross sections (Ω) to be directly calculated from measured drift times under well-defined experimental conditions. However, such "first principle" calculations are not straightforward for Traveling Wave (T-Wave) mobility separations due to the range of factors that influence ion motion through the mobility cell. If collision cross section information is required from T-Wave mobility separations, then calibration of the instruments using known standards is essential for each set of experimental conditions. To facilitate such calibration, we have designed and generated an artificial protein based on the QconCAT technology, QCAL-IM, which upon proteolysis can be used as a universal ion mobility calibration standard. This single unique standard enables empirical calculation of peptide ion collision cross sections from the drift time on a T-Wave mobility instrument.
Collapse
Affiliation(s)
- Ross Chawner
- Manchester Institute of Biotechnology, Michael Barber Centre for Mass Spectrometry, School of Chemistry, University of Manchester, Manchester, M1 7DN, United Kingdom
| | | | | | | | | | | |
Collapse
|
50
|
Recent developments in liquid chromatography–mass spectrometry and related techniques. J Chromatogr A 2012; 1259:3-15. [DOI: 10.1016/j.chroma.2012.08.072] [Citation(s) in RCA: 228] [Impact Index Per Article: 19.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2012] [Revised: 08/22/2012] [Accepted: 08/23/2012] [Indexed: 11/22/2022]
|