1
|
Leung M, Zhang L, Li X, Yu HZ. Superhydrophobic Paper Strips with Embedded Agarose-Anthocyanin Mini-Discs for Point-of-Need Quantitative pH Measurements. Anal Chem 2024; 96:15808-15815. [PMID: 39300344 DOI: 10.1021/acs.analchem.4c04242] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/22/2024]
Abstract
Commercial pH paper is a quick and simple tool for measuring a solution's acidity/basicity, but it only provides qualitative or semi-quantitative results, and the synthetic indicator dyes within can be toxic or carcinogenic. Although pH meters enable more accurate and quantitative analysis, they are less convenient to operate and are tedious to calibrate. This presents a need for an alternative pH testing method for applications where it is not easy or possible to use a pH meter, yet quantitative results are desired. We report herein the fabrication of a pH test strip made from superhydrophobic paper and agarose-anthocyanin film discs. In the proposed method, test strips are dipped into samples and then imaged with a portable scanner (or a smartphone). The color of the film is extracted with ImageJ software (or a mobile app), using the RGB color system. By generating a calibration curve relating the film color to the sample pH using standard buffer solutions, we are able to quantify the pH of beverages and other liquids with an accuracy and precision comparable to that of a pH meter. The test strips offer the same convenience as conventional pH paper, with the added capabilities of quantitation and multiplexed testing, which presents a practical tool for point-of-need pH analysis.
Collapse
Affiliation(s)
- Michelle Leung
- Department of Chemistry, Simon Fraser University, Burnaby, British Columbia V5A 1S6, Canada
| | - Lingling Zhang
- College of Biomedical Engineering, Taiyuan University of Technology, Yuci, Shanxi 030600, China
| | - Xiaochun Li
- College of Biomedical Engineering, Taiyuan University of Technology, Yuci, Shanxi 030600, China
| | - Hua-Zhong Yu
- Department of Chemistry, Simon Fraser University, Burnaby, British Columbia V5A 1S6, Canada
- College of Biomedical Engineering, Taiyuan University of Technology, Yuci, Shanxi 030600, China
| |
Collapse
|
2
|
Chen C, Liu J, Lu J, Wang Y, Zhai J, Zhao H, Lu N. In Situ Collection and SERS Detection of Nitrite in Exhalations on Facemasks Based on Wettability Differences. ACS Sens 2024; 9:3680-3688. [PMID: 38958469 DOI: 10.1021/acssensors.4c00857] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/04/2024]
Abstract
As one of the common carriers of biological information, along with human urine specimens and blood, exhaled breath condensate (EBC) carries reliable and rich information about the body's metabolism to track human physiological normal/abnormal states and environmental exposures. What is more, EBC has gained extensive attention because of the convenient and nondestructive sampling. Facemasks, which act as a physical filter barrier between human exhaled breath and inhaled substances from the external environment, are safe, noninvasive, and economic devices for direct sampling of human exhaled breath and inhaled substances. Inspired by the ability of fog collection of Namib desert beetle, a strategy for in situ collecting and detecting EBC with surface-enhanced Raman scattering is illustrated. Based on the intrinsic and unique wettability differences between the squares and the surrounding area of the pattern on facemasks, the hydrophilic squares can capture exhaled droplets and spontaneously enrich the analytes and silver nanocubes (AgNCs), resulting in good repeatability in situ detection. Using R6G as the probe molecule, the minimal detectable concentration can reach as low as 10-16 M, and the relative standard deviation is less than 7%. This proves that this strategy can achieve high detection sensitivity and high detection repeatability. Meanwhile, this strategy is applicable for portable nitrite analysis in EBC and may provide an inspiration for monitoring other biomarkers in EBC.
Collapse
Affiliation(s)
- Chunning Chen
- State Key Laboratory of Supramolecular Structure and Materials, College of Chemistry, Jilin University, Changchun 130012, P. R. China
| | - Jiaqi Liu
- State Key Laboratory of Supramolecular Structure and Materials, College of Chemistry, Jilin University, Changchun 130012, P. R. China
| | - Jiaxin Lu
- State Key Laboratory of Supramolecular Structure and Materials, College of Chemistry, Jilin University, Changchun 130012, P. R. China
| | - Yalei Wang
- State Key Laboratory of Supramolecular Structure and Materials, College of Chemistry, Jilin University, Changchun 130012, P. R. China
| | - Jingtong Zhai
- State Key Laboratory of Supramolecular Structure and Materials, College of Chemistry, Jilin University, Changchun 130012, P. R. China
| | - Hongkun Zhao
- State Key Laboratory of Supramolecular Structure and Materials, College of Chemistry, Jilin University, Changchun 130012, P. R. China
| | - Nan Lu
- State Key Laboratory of Supramolecular Structure and Materials, College of Chemistry, Jilin University, Changchun 130012, P. R. China
| |
Collapse
|
3
|
Xu M, Bian Z, Chen Q, Wang H, Chen C, Lu H. Polymeric microlens array formed on a discontinuous wetting surface using a self-assembly technique. APPLIED OPTICS 2024; 63:4380-4385. [PMID: 38856617 DOI: 10.1364/ao.518091] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/11/2024] [Accepted: 05/08/2024] [Indexed: 06/11/2024]
Abstract
In this paper, we demonstrate a facile way to prepare polymeric microlens arrays (MLAs) based on a discontinuous wetting surface using a self-assembly technique. A patterned hydrophobic-octadecyltrichlorosilane (OTS) surface was prepared by U V/O 3 irradiation through a shadow mask. The area exposed to U V/O 3 irradiation turned highly hydrophilic, whereas the area protected by the mask remained highly hydrophobic, generating the patterned OTS surface. The surface energy of the OTS/glass surface changed from 23 to 72.8 mN/m after 17 min of U V/O 3 treatment. The scribing of the optical glue-NOA 81 onto the microhole array enabled one to obtain the MLAs due to the generation of the NOA 81 droplet array via the surface tension. After UV light curing, the cured NOA 81 droplet array with uniform dimensions within a large area exhibited excellent MLA characteristics. Moreover, the method developed in this study is simple in operation, low-cost, and requires neither a clean room nor expensive equipment.
Collapse
|
4
|
Chen JL, Njoku DI, Tang C, Gao Y, Chen J, Peng YK, Sun H, Mao G, Pan M, Tam NFY. Advances in Microfluidic Paper-Based Analytical Devices (µPADs): Design, Fabrication, and Applications. SMALL METHODS 2024:e2400155. [PMID: 38781604 DOI: 10.1002/smtd.202400155] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/30/2024] [Revised: 05/01/2024] [Indexed: 05/25/2024]
Abstract
Microfluidic Paper-based Analytical Devices (µPADs) have emerged as a new class of microfluidic systems, offering numerous advantages over traditional microfluidic chips. These advantages include simplicity, cost-effectiveness, stability, storability, disposability, and portability. As a result, various designs for different types of assays are developed and investigated. In recent years, µPADs are combined with conventional detection methods to enable rapid on-site detection, providing results comparable to expensive and sophisticated large-scale testing methods that require more time and skilled personnel. The application of µPAD techniques is extensive in environmental quality control/analysis, clinical diagnosis, and food safety testing, paving the way for on-site real-time diagnosis as a promising future development. This review focuses on the recent research advancements in the design, fabrication, material selection, and detection methods of µPADs. It provides a comprehensive understanding of their principles of operation, applications, and future development prospects.
Collapse
Affiliation(s)
- Jian Lin Chen
- Department of Applied Science, School of Science and Technology, Hong Kong Metropolitan University, Good Shepherd Street, Ho Man Tin, Kowloon, Hong Kong SAR, P. R. China
- State Key Laboratory of Marine Pollution, City University of Hong Kong, Tat Chee Avenue, Kowloon, Hong Kong SAR, P. R. China
- Shenzhen Research Institute of City University of Hong Kong, Shenzhen, 518057, P. R. China
| | - Demian Ifeanyi Njoku
- Department of Applied Science, School of Science and Technology, Hong Kong Metropolitan University, Good Shepherd Street, Ho Man Tin, Kowloon, Hong Kong SAR, P. R. China
| | - Cui Tang
- Department of Applied Science, School of Science and Technology, Hong Kong Metropolitan University, Good Shepherd Street, Ho Man Tin, Kowloon, Hong Kong SAR, P. R. China
| | - Yaru Gao
- Department of Applied Science, School of Science and Technology, Hong Kong Metropolitan University, Good Shepherd Street, Ho Man Tin, Kowloon, Hong Kong SAR, P. R. China
| | - Jiayu Chen
- Department of Applied Science, School of Science and Technology, Hong Kong Metropolitan University, Good Shepherd Street, Ho Man Tin, Kowloon, Hong Kong SAR, P. R. China
| | - Yung-Kang Peng
- Shenzhen Research Institute of City University of Hong Kong, Shenzhen, 518057, P. R. China
- Department of Chemistry, City University of Hong Kong, Tat Chee Avenue, Kowloon, Hong Kong SAR, P. R. China
| | - Hongyan Sun
- Shenzhen Research Institute of City University of Hong Kong, Shenzhen, 518057, P. R. China
- Department of Chemistry, City University of Hong Kong, Tat Chee Avenue, Kowloon, Hong Kong SAR, P. R. China
| | - Guozhu Mao
- School of Environmental Science and Engineering, Tianjin University, Tianjin, 300350, P. R. China
| | - Min Pan
- Department of Applied Science, School of Science and Technology, Hong Kong Metropolitan University, Good Shepherd Street, Ho Man Tin, Kowloon, Hong Kong SAR, P. R. China
| | - Nora Fung-Yee Tam
- Department of Applied Science, School of Science and Technology, Hong Kong Metropolitan University, Good Shepherd Street, Ho Man Tin, Kowloon, Hong Kong SAR, P. R. China
- State Key Laboratory of Marine Pollution, City University of Hong Kong, Tat Chee Avenue, Kowloon, Hong Kong SAR, P. R. China
- Shenzhen Research Institute of City University of Hong Kong, Shenzhen, 518057, P. R. China
- Department of Chemistry, City University of Hong Kong, Tat Chee Avenue, Kowloon, Hong Kong SAR, P. R. China
| |
Collapse
|
5
|
Soman SS, Samad SA, Venugopalan P, Kumawat N, Kumar S. Microfluidic paper analytic device (μPAD) technology for food safety applications. BIOMICROFLUIDICS 2024; 18:031501. [PMID: 38706979 PMCID: PMC11068414 DOI: 10.1063/5.0192295] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/19/2023] [Accepted: 04/15/2024] [Indexed: 05/07/2024]
Abstract
Foodborne pathogens, food adulterants, allergens, and toxic chemicals in food can cause major health hazards to humans and animals. Stringent quality control measures at all stages of food processing are required to ensure food safety. There is, therefore, a global need for affordable, reliable, and rapid tests that can be conducted at different process steps and processing sites, spanning the range from the sourcing of food to the end-product acquired by the consumer. Current laboratory-based food quality control tests are well established, but many are not suitable for rapid on-site investigations and are costly. Microfluidic paper analytical devices (μPADs) are a fast-growing field in medical diagnostics that can fill these gaps. In this review, we describe the latest developments in the applications of microfluidic paper analytic device (μPAD) technology in the food safety sector. State-of-the-art μPAD designs and fabrication methods, microfluidic assay principles, and various types of μPAD devices with food-specific applications are discussed. We have identified the prominent research and development trends and future directions for maximizing the value of microfluidic technology in the food sector and have highlighted key areas for improvement. We conclude that the μPAD technology is promising in food safety applications by using novel materials and improved methods to enhance the sensitivity and specificity of the assays, with low cost.
Collapse
Affiliation(s)
- Soja Saghar Soman
- Division of Engineering, New York University Abu Dhabi, Abu Dhabi, P.O. Box 129188, UAE
| | - Shafeek Abdul Samad
- Division of Engineering, New York University Abu Dhabi, Abu Dhabi, P.O. Box 129188, UAE
| | | | - Nityanand Kumawat
- Division of Engineering, New York University Abu Dhabi, Abu Dhabi, P.O. Box 129188, UAE
| | | |
Collapse
|
6
|
Xu M, Chen C, Chang X, Chen Q, Lu H. Dielectric Liquid Microlens Array with Tunable Focal Length Based on Microdroplet Array Created via Dip-Coating Method. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2024; 40:5809-5817. [PMID: 38445621 DOI: 10.1021/acs.langmuir.3c03689] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/07/2024]
Abstract
A dielectric liquid microlens array (LMA) with a tunable focal length was fabricated by using a microdroplet array generated through the dip-coating method. The process began with treating the octadecyltrichlorosilane (OTS) layer with selective UV/O3 irradiation for 20 min to establish a hydrophilic-hydrophobic patterning surface. The substrate was subsequently immersed in glycerol and then withdrawn at a constant rate to create a microdroplet array. Upon filling the cell with matching oil (SL5267) and placing it within a square array of a 200 μm diameter glycerol microdroplet array, the LMA was produced. The focal length ranged from approximately -0.96 to -0.3 mm within a voltage range of 0 to 60 Vrms. The glycerol microdroplets, characterized by their shapes, sizes, curvatures, and filling factors, can be precisely controlled by designing an OTS patterning or adjusting the dip-coating speed. This approach offers a rapid and high-throughput method for preparation. Our approach to fabricating tunable LMA offers several advantages, including simplicity of fabrication, uniform structural properties, cost-effectiveness, polarization independence, and excellent optical performance. These focus-tunable LMAs hold significant potential for applications in image processing, 3D displays, medical endoscopy, and military technologies.
Collapse
Affiliation(s)
- Miao Xu
- Academy of Opto-Electric Technology, Special Display and Imaging Technology, Innovation Center of Anhui Province, National Engineering Laboratory of Special Display Technology, Anhui Province Key Laboratory of Measuring Theory and Precision Instrument, School of Instrument Science and Optoelectronics Engineering, Anhui Provincial Engineering Research Center of Semiconductor Inspection Technology and Instrument, Hefei University of Technology, Hefei 230009, China
| | - Cuifen Chen
- Academy of Opto-Electric Technology, Special Display and Imaging Technology, Innovation Center of Anhui Province, National Engineering Laboratory of Special Display Technology, Anhui Province Key Laboratory of Measuring Theory and Precision Instrument, School of Instrument Science and Optoelectronics Engineering, Anhui Provincial Engineering Research Center of Semiconductor Inspection Technology and Instrument, Hefei University of Technology, Hefei 230009, China
| | - Xueying Chang
- Academy of Opto-Electric Technology, Special Display and Imaging Technology, Innovation Center of Anhui Province, National Engineering Laboratory of Special Display Technology, Anhui Province Key Laboratory of Measuring Theory and Precision Instrument, School of Instrument Science and Optoelectronics Engineering, Anhui Provincial Engineering Research Center of Semiconductor Inspection Technology and Instrument, Hefei University of Technology, Hefei 230009, China
| | - Qilong Chen
- Academy of Opto-Electric Technology, Special Display and Imaging Technology, Innovation Center of Anhui Province, National Engineering Laboratory of Special Display Technology, Anhui Province Key Laboratory of Measuring Theory and Precision Instrument, School of Instrument Science and Optoelectronics Engineering, Anhui Provincial Engineering Research Center of Semiconductor Inspection Technology and Instrument, Hefei University of Technology, Hefei 230009, China
| | - Hongbo Lu
- Academy of Opto-Electric Technology, Special Display and Imaging Technology, Innovation Center of Anhui Province, National Engineering Laboratory of Special Display Technology, Anhui Province Key Laboratory of Measuring Theory and Precision Instrument, School of Instrument Science and Optoelectronics Engineering, Anhui Provincial Engineering Research Center of Semiconductor Inspection Technology and Instrument, Hefei University of Technology, Hefei 230009, China
| |
Collapse
|
7
|
Zhang L, Reddy DO, Salomons TT, Oleschuk RD. Micro "Hyper-Channels" on Laser-Refined Cellulose Structures. SMALL METHODS 2024; 8:e2301164. [PMID: 38009774 DOI: 10.1002/smtd.202301164] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/29/2023] [Indexed: 11/29/2023]
Abstract
Controlled liquid transportation is widely applied in both academia and industry. However, liquid transport applications are limited by parameters such as driving forces, precision, and velocity. Herein, a simple laser-refining technology is presented to produce micro "hyper-channels". A cellulose substrate is rendered hydrophobic through silanization and refined with a laser to produce both hierarchical nanostructures and a wettability contrast simultaneously. Such a method enables faster ("hyper"-channel) aqueous liquid transportation (≈25X, 50 mm s-1 ) compared to conventional methods. Complex patterns can be readily produced at different scales with spatial resolution as low as 50 µm. This technique also controls the refining depth on the thin paper substrate. Shallow channels can be fabricated on thin paper substrates that enable fluidic channel-crossover without liquid mixing. With certain parameters, the technique creates "portals" through the substrate, allowing trans-dimensional liquid transportation between two layers of a single sheet of substrate. The fluid throughput can be increased, while also permitting fluidic channel crossover without liquid mixing. By introducing multiple portals, the controlled fluid can transfer trans-dimensionally several times, enabling further fluidic complexity. The real-life utility of the method is demonstrated by creating a trans-dimensional microfluidic device for colorimetric detection.
Collapse
Affiliation(s)
- Lishen Zhang
- Department of Chemistry, Queen's University, Kingston, ON, K7L 3N6, Canada
| | - Daniel O Reddy
- Department of Chemistry, Queen's University, Kingston, ON, K7L 3N6, Canada
| | - Timothy T Salomons
- Department of Chemistry, Queen's University, Kingston, ON, K7L 3N6, Canada
| | - Richard D Oleschuk
- Department of Chemistry, Queen's University, Kingston, ON, K7L 3N6, Canada
| |
Collapse
|
8
|
Kuang C, Chen S, Luo M, Zhang Q, Sun X, Han S, Wang Q, Stanishev V, Darakchieva V, Crispin R, Fahlman M, Zhao D, Wen Q, Jonsson MP. Switchable Broadband Terahertz Absorbers Based on Conducting Polymer-Cellulose Aerogels. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2024; 11:e2305898. [PMID: 37997181 PMCID: PMC10797431 DOI: 10.1002/advs.202305898] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/21/2023] [Revised: 10/18/2023] [Indexed: 11/25/2023]
Abstract
Terahertz (THz) technologies provide opportunities ranging from calibration targets for satellites and telescopes to communication devices and biomedical imaging systems. A main component will be broadband THz absorbers with switchability. However, optically switchable materials in THz are scarce and their modulation is mostly available at narrow bandwidths. Realizing materials with large and broadband modulation in absorption or transmission forms a critical challenge. This study demonstrates that conducting polymer-cellulose aerogels can provide modulation of broadband THz light with large modulation range from ≈ 13% to 91% absolute transmission, while maintaining specular reflection loss < -30 dB. The exceptional THz modulation is associated with the anomalous optical conductivity peak of conducting polymers, which enhances the absorption in its oxidized state. The study also demonstrates the possibility to reduce the surface hydrophilicity by simple chemical modifications, and shows that broadband absorption of the aerogels at optical frequencies enables de-frosting by solar-induced heating. These low-cost, aqueous solution-processable, sustainable, and bio-friendly aerogels may find use in next-generation intelligent THz devices.
Collapse
Affiliation(s)
- Chaoyang Kuang
- Laboratory of Organic Electronics, Department of Science and Technology (ITN)Linköping UniversityNorrköpingSE‐601 74Sweden
| | - Shangzhi Chen
- Laboratory of Organic Electronics, Department of Science and Technology (ITN)Linköping UniversityNorrköpingSE‐601 74Sweden
| | - Min Luo
- School of Electronic Science and Engineering, State Key Laboratory of Electronic Thin Film and Integrated DevicesUniversity of Electronic Science and Technology of ChinaChengduSichuan610 054P. R. China
| | - Qilun Zhang
- Laboratory of Organic Electronics, Department of Science and Technology (ITN)Linköping UniversityNorrköpingSE‐601 74Sweden
- Wallenberg Wood Science CenterLinköping UniversityNorrköpingSE‐601 74Sweden
| | - Xiao Sun
- School of Electronic Science and Engineering, State Key Laboratory of Electronic Thin Film and Integrated DevicesUniversity of Electronic Science and Technology of ChinaChengduSichuan610 054P. R. China
| | - Shaobo Han
- School of Textile Material and EngineeringWuyi University22 DongchengcunJiangmenGuangdong529 020P. R. China
| | - Qingqing Wang
- Laboratory of Organic Electronics, Department of Science and Technology (ITN)Linköping UniversityNorrköpingSE‐601 74Sweden
| | - Vallery Stanishev
- Terahertz Materials Analysis Center (THeMAC) and Center for III‐N Technology, C3NiT‐Janzèn, Department of Physics, Chemistry and Biology (IFM)Linköping UniversityLinköpingSE‐581 83Sweden
- Solid State Physics and NanoLundLund UniversityLundSE‐221 00Sweden
| | - Vanya Darakchieva
- Terahertz Materials Analysis Center (THeMAC) and Center for III‐N Technology, C3NiT‐Janzèn, Department of Physics, Chemistry and Biology (IFM)Linköping UniversityLinköpingSE‐581 83Sweden
- Solid State Physics and NanoLundLund UniversityLundSE‐221 00Sweden
| | - Reverant Crispin
- Laboratory of Organic Electronics, Department of Science and Technology (ITN)Linköping UniversityNorrköpingSE‐601 74Sweden
- Wallenberg Wood Science CenterLinköping UniversityNorrköpingSE‐601 74Sweden
| | - Mats Fahlman
- Laboratory of Organic Electronics, Department of Science and Technology (ITN)Linköping UniversityNorrköpingSE‐601 74Sweden
- Wallenberg Wood Science CenterLinköping UniversityNorrköpingSE‐601 74Sweden
| | - Dan Zhao
- Laboratory of Organic Electronics, Department of Science and Technology (ITN)Linköping UniversityNorrköpingSE‐601 74Sweden
| | - Qiye Wen
- School of Electronic Science and Engineering, State Key Laboratory of Electronic Thin Film and Integrated DevicesUniversity of Electronic Science and Technology of ChinaChengduSichuan610 054P. R. China
- Yangtze Delta Region Institute (Huzhou)University of Electronic Science and Technology of ChinaHuzhouZhejiang313 001P. R. China
| | - Magnus P. Jonsson
- Laboratory of Organic Electronics, Department of Science and Technology (ITN)Linköping UniversityNorrköpingSE‐601 74Sweden
- Wallenberg Wood Science CenterLinköping UniversityNorrköpingSE‐601 74Sweden
- Stellenbosch Institute for Advanced Study (STIAS)Wallenberg Research Center at Stellenbosch UniversityStellenbosch7600South Africa
| |
Collapse
|
9
|
Arias A, Windham PE, Cheyne NA, Gilliland WM. Rapid fabrication of hydrophobic/hydrophilic patterns on paper substrates for paper spray mass spectrometry. Analyst 2023; 148:5496-5506. [PMID: 37782094 PMCID: PMC10849044 DOI: 10.1039/d3an01071f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/03/2023]
Abstract
A simple, rapid chemical coating and patterning method was developed and optimized for paper-based substrates for use in paper spray mass spectrometry (PS-MS). A variety of chlorosilanes were explored for coating paper substrates, and their effectiveness in forming hydrophobic surfaces was characterized via contact angle goniometry, scanning electron microscopy, and energy dispersive X-ray spectroscopy. Trichloromethylsilane was selected as the primary coating agent because of the short time required to produce a hydrophobic surface (contact angle > 130°), as well as the ease of patterning. Patterning was performed using 3D-printed masks and an oxygen/plasma cleaner. Optimal mask thickness and oxygen/plasma cleaning parameters were determined to produce channels varying from 0.5 to 2.5 mm in width. The effectiveness of the patterned substrates for PS-MS was determined via analysis of four antiretrovirals: emtricitabine, lamivudine, efavirenz, and dolutegravir. Calibration curves were made for each antiretroviral at varying channel widths, and the limits of detection and limits of quantification for each drug were determined. These results show that this patterning method results in an average 7.2-fold improvement in sensitivity and an average 190-fold improvement in limits of detection over uncoated paper substrates in a neat matrix. In a proof-of-concept experiment, calibration curves were generated for each antiretroviral in urine. A patterned paper substrate with a 2-mm channel resulted in an average 7.4-fold improvement in sensitivity and an average 18-fold improvement in limits of detection over uncoated paper substrates.
Collapse
Affiliation(s)
- Austin Arias
- Department of Chemistry, Furman University, Greenville, SC 29613, USA.
| | - Peyton E Windham
- Department of Chemistry, Furman University, Greenville, SC 29613, USA.
| | - Natalie A Cheyne
- Department of Chemistry, Furman University, Greenville, SC 29613, USA.
| | | |
Collapse
|
10
|
Choi J, Lee EH, Kang SM, Jeong HH. A Facile Method to Fabricate an Enclosed Paper-Based Analytical Device via Double-Sided Patterning for Ionic Contaminant Detection. BIOSENSORS 2023; 13:915. [PMID: 37887108 PMCID: PMC10605057 DOI: 10.3390/bios13100915] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/29/2023] [Revised: 10/03/2023] [Accepted: 10/03/2023] [Indexed: 10/28/2023]
Abstract
Microfluidic paper-based analytical devices (μPADs) have been developed for use in a variety of diagnosis and analysis fields. However, conventional μPADs with an open-channel system have limitations for application as analytical platforms mainly because of the evaporation and contamination of the sample solution. This study demonstrates the design and fabrication of an enclosed three-dimensional(3D)-μPAD and its application as a primary early analysis platform for ionic contaminants. To generate the hydrophobic PDMS barrier, double-sided patterning is carried out using a PDMS blade-coated stamp mold that is fabricated using 3D printing. The selective PDMS patterning can be achieved with controlled PDMS permeation of the cellulose substrate using 3D-designed stamp molds. We find the optimal conditions enabling the formation of enclosed channels, including round shape pattern and inter-pattern distance of 10 mm of stamp design, contact time of 0.5 min, and spacer height of 300 µm of double-sided patterning procedure. As a proof of concept, this enclosed 3D-μPAD is used for the simultaneous colorimetric detection of heavy metal ions in a concentration range of 0.1-2000 ppm, including nickel (Ni2+), copper (Cu2+), mercury (Hg2+), and radioactive isotope cesium-137 ions (Cs+). We confirm that qualitative analysis and image-based quantitative analysis with high reliability are possible through rapid color changes within 3 min. The limits of detection (LOD) for 0.55 ppm of Ni2+, 5.05 ppm of Cu2+, 0.188 ppm of Hg2+, and 0.016 ppm of Cs+ are observed, respectively. In addition, we confirm that the analysis is highly reliable in a wide range of ion concentrations with CV values below 3% for Ni2+ (0.56%), Cu2+ (0.45%), Hg2+ (1.35%), and Cs+ (2.18%). This method could be a promising technique to develop a 3D-μPAD with various applications as a primary early analysis device in the environmental and biological industries.
Collapse
Affiliation(s)
- Jinsol Choi
- Department of Chemical and Biomolecular Engineering, Chonnam National University, 50 Daehak-ro, Yeosu 59626, Jeollanam-do, Republic of Korea;
| | - Eun-Ho Lee
- Department of Green Chemical Engineering, Sangmyung University, 31 Sangmyungdae-gil, Cheonan 31066, Chungcheongnam-do, Republic of Korea;
| | - Sung-Min Kang
- Department of Green Chemical Engineering, Sangmyung University, 31 Sangmyungdae-gil, Cheonan 31066, Chungcheongnam-do, Republic of Korea;
- Future Environment and Energy Research Institute, Sangmyung University, 31 Sangmyungdae-gil, Cheonan 31066, Chungcheongnam-do, Republic of Korea
| | - Heon-Ho Jeong
- Department of Chemical and Biomolecular Engineering, Chonnam National University, 50 Daehak-ro, Yeosu 59626, Jeollanam-do, Republic of Korea;
| |
Collapse
|
11
|
Li X, Dai B, Wang L, Yang X, Xu T, Zhang X. Radiative cooling and anisotropic wettability in E-textile for comfortable biofluid monitoring. Biosens Bioelectron 2023; 237:115434. [PMID: 37301178 DOI: 10.1016/j.bios.2023.115434] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2023] [Revised: 04/20/2023] [Accepted: 05/25/2023] [Indexed: 06/12/2023]
Abstract
Long-term wearing comfort is essential for future advanced electronic textiles (e-textiles). Herein, we fabricate a skin-comfortable e-textile for long-term wearing experience on human epidermis. Such e-textile was simply fabricated through two different dip coating methods and single-side air plasma treatment, which couples radiative thermal and moisture management for biofluid monitoring. The silk-based substrate with improved optical properties and anisotropic wettability can provide a temperature drop of 1.4 °C under strong sunlight. Moreover, the anisotropic wettability of the e-textile can provide a dryer skin microenvironment by comparing with traditional fabric. The fiber electrodes weaving into the inner side of the substrate can noninvasively monitor multiple sweat biomarkers (i.e., pH, uric acid, and Na+). Such a synergistic strategy may pave a new path to design next-generation e-textiles with significantly improved comfort.
Collapse
Affiliation(s)
- Xiangnan Li
- School of Biomedical Engineering, Shenzhen University Medical School, Shenzhen University, Shenzhen, Guangdong, 518060, PR China
| | - Bing Dai
- School of Biomedical Engineering, Shenzhen University Medical School, Shenzhen University, Shenzhen, Guangdong, 518060, PR China
| | - Lirong Wang
- School of Biomedical Engineering, Shenzhen University Medical School, Shenzhen University, Shenzhen, Guangdong, 518060, PR China
| | - Xuejun Yang
- School of Biomedical Engineering, Shenzhen University Medical School, Shenzhen University, Shenzhen, Guangdong, 518060, PR China
| | - Tailin Xu
- School of Biomedical Engineering, Shenzhen University Medical School, Shenzhen University, Shenzhen, Guangdong, 518060, PR China.
| | - Xueji Zhang
- School of Biomedical Engineering, Shenzhen University Medical School, Shenzhen University, Shenzhen, Guangdong, 518060, PR China
| |
Collapse
|
12
|
Mitrogiannopoulou AM, Tselepi V, Ellinas K. Polymeric and Paper-Based Lab-on-a-Chip Devices in Food Safety: A Review. MICROMACHINES 2023; 14:986. [PMID: 37241610 PMCID: PMC10223399 DOI: 10.3390/mi14050986] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/13/2023] [Revised: 04/27/2023] [Accepted: 04/28/2023] [Indexed: 05/28/2023]
Abstract
Food quality and safety are important to protect consumers from foodborne illnesses. Currently, laboratory scale analysis, which takes several days to complete, is the main way to ensure the absence of pathogenic microorganisms in a wide range of food products. However, new methods such as PCR, ELISA, or even accelerated plate culture tests have been proposed for the rapid detection of pathogens. Lab-on-chip (LOC) devices and microfluidics are miniaturized devices that can enable faster, easier, and at the point of interest analysis. Nowadays, methods such as PCR are often coupled with microfluidics, providing new LOC devices that can replace or complement the standard methods by offering highly sensitive, fast, and on-site analysis. This review's objective is to present an overview of recent advances in LOCs used for the identification of the most prevalent foodborne and waterborne pathogens that put consumer health at risk. In particular, the paper is organized as follows: first, we discuss the main fabrication methods of microfluidics as well as the most popular materials used, and then we present recent literature examples for LOCs used for the detection of pathogenic bacteria found in water and other food samples. In the final section, we summarize our findings and also provide our point of view on the challenges and opportunities in the field.
Collapse
Affiliation(s)
| | | | - Kosmas Ellinas
- Department of Food Science and Nutrition, School of the Environment, University of the Aegean, Ierou Lochou & Makrygianni St, GR 81400 Myrina, Greece
| |
Collapse
|
13
|
Roller RM, Rea A, Lieberman M. The air-gap PAD: a roll-to-roll-compatible fabrication method for paper microfluidics. LAB ON A CHIP 2023; 23:1918-1925. [PMID: 36883463 DOI: 10.1039/d2lc01164f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/18/2023]
Abstract
Paper-based analytical devices (PADs) offer a low-cost, user-friendly platform for rapid point-of-use testing. Without scalable fabrication methods, however, few PADs make it out of the academic laboratory and into the hands of end users. Previously, wax printing was considered an ideal PAD fabrication method, but given that wax printers are no longer commercially available, alternatives are needed. Here, we present one such alternative: the air-gap PAD. Air-gap PADs consist of hydrophilic paper test zones, separated by "air gaps" and affixed to a hydrophobic backing with double-sided adhesive. The primary appeal of this design is its compatibility with roll-to-roll equipment for large-scale manufacturing. In this study, we examine design considerations for air-gap PADs, compare the performance of wax-printed and air-gap PADs, and report on a pilot-scale roll-to-roll production run of air-gap PADs in partnership with a commercial test-strip manufacturer. Air-gap devices performed comparably to their wax-printed counterparts in Washburn flow experiments, a paper-based titration, and a 12-lane pharmaceutical screening device. Using roll-to-roll manufacturing, we produced 2700 feet of air-gap PADs for as little as $0.03 per PAD.
Collapse
Affiliation(s)
- Rachel M Roller
- Department of Chemistry and Biochemistry, University of Notre Dame, Notre Dame, IN, 46556, USA.
| | - Angela Rea
- Department of Chemistry and Biochemistry, University of Notre Dame, Notre Dame, IN, 46556, USA.
| | - Marya Lieberman
- Department of Chemistry and Biochemistry, University of Notre Dame, Notre Dame, IN, 46556, USA.
| |
Collapse
|
14
|
Wang X, Wang Y, Guo C, Zhang X, Wang Y, Lv L, Wang X, Wei M. A pattern-free paper enzyme biosensor for one-step detection of fish freshness indicator hypoxanthine with a microfluidic aggregation effect. Food Chem 2023; 405:134811. [DOI: 10.1016/j.foodchem.2022.134811] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2022] [Revised: 10/27/2022] [Accepted: 10/28/2022] [Indexed: 11/11/2022]
|
15
|
Zhang Y, Khan AK, See D, Ying JY. Enhancing Protein Adsorption for Improved Lateral Flow Assay on Cellulose Paper by Depleting Inert Additive Films Using Reactive Plasma. ACS APPLIED MATERIALS & INTERFACES 2023; 15:6561-6571. [PMID: 36692231 DOI: 10.1021/acsami.2c21501] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/17/2023]
Abstract
Paper-based platforms are ideal for on-site surveillance of infectious diseases in low-resource settings due to their simplicity, self-containment, and low cost. The two most popular materials used in paper-based platforms are nitrocellulose and cellulose. The nitrocellulose membrane has a high protein binding affinity, but its high price is an issue. Cellulose paper is inexpensive and allows intricate fluidic control for more sophisticated biochemical reactions, but it has a low protein binding affinity. By examining the microstructure of cellulose paper, we discover that cellulose fibers in the paper matrix are covered by thin films, which possibly result from the additives used in the paper-making process. Our finding suggests that the thin films are inert to protein adsorption. By selectively depleting the inert films with reactive plasma, we were able to enhance the protein adsorption to the cellulose paper and improve the performance of lateral flow assays. The performance of certain lateral flow assays on the plasma-treated cellulose paper is equivalent to or better than that on the nitrocellulose membrane. This leads us to believe that cellulose paper with a microstructure exclusively designed for protein binding, either by refined paper manufacturing process or by post-manufacture modification such as the plasma treatment presented herein, can potentially replace nitrocellulose as a less expensive paper substrate for point-of-care rapid test kits.
Collapse
Affiliation(s)
- Yi Zhang
- NanoBio Lab, Institute of Institute of Materials Research and Engineering, Agency for Science, Technology and Research (A*STAR), 31 Biopolis Way, The Nanos, Singapore 138669, Singapore
- School of Electronic Science and Engineering, University of Electronic Science and Technology of China, Chengdu, Sichuan 611731, China
| | - Ahmed Khalil Khan
- NanoBio Lab, Institute of Institute of Materials Research and Engineering, Agency for Science, Technology and Research (A*STAR), 31 Biopolis Way, The Nanos, Singapore 138669, Singapore
| | - Deanna See
- NanoBio Lab, Institute of Institute of Materials Research and Engineering, Agency for Science, Technology and Research (A*STAR), 31 Biopolis Way, The Nanos, Singapore 138669, Singapore
| | - Jackie Y Ying
- NanoBio Lab, Institute of Institute of Materials Research and Engineering, Agency for Science, Technology and Research (A*STAR), 31 Biopolis Way, The Nanos, Singapore 138669, Singapore
- A*STAR Infectious Diseases Labs, NanoBio Lab, A*STAR, 31 Biopolis Way, The Nanos, Singapore 138669, Singapore
| |
Collapse
|
16
|
Ghasemi F, Fahimi-Kashani N, Bigdeli A, Alshatteri AH, Abbasi-Moayed S, Al-Jaf SH, Merry MY, Omer KM, Hormozi-Nezhad MR. Paper-based optical nanosensors – A review. Anal Chim Acta 2022; 1238:340640. [DOI: 10.1016/j.aca.2022.340640] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2022] [Revised: 11/15/2022] [Accepted: 11/16/2022] [Indexed: 11/23/2022]
|
17
|
Mollaie E, Asiaei S, Aryan H. Nitrite enhanced detection from saliva by simple geometrical modifications of paper-based micromixers. MICROFLUIDICS AND NANOFLUIDICS 2022; 26:88. [PMID: 36246785 PMCID: PMC9554860 DOI: 10.1007/s10404-022-02596-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 05/09/2022] [Accepted: 09/28/2022] [Indexed: 06/16/2023]
Abstract
Dysregulation of nitric oxide (NO) and it's two relatively stable metabolites, nitrite, and nitrate, in SARS-CoV-2, are reported in infected populations, especially for nitrates levels > 68.4 μmol/L. In this paper, we measure the abnormal presence of nitrite in the saliva by developing a cheap μPAD for colorimetric detection through the modified Griess reaction. This includes a diazotization reaction between nitrite and Griess reagent, including Sulfanilamide and N-Naphthyl-ethylenediamine in an acidic medium, causing a pink Azo compound. The modifications are suggested by a numerical method model that couples the mass flux with the porosity medium equations (convection, diffusion and, dispersion) that improves the mixing process. The mixing index was quantified from the concentration deviation method via simulation of a homogeneous two-phase flow in a porous environment. Five μPAD designs were fabricated to verify the simulation results of mixing enhancement on the Griess reactants in saliva samples. The investigated geometries include straight, helical, zig-zag, square wave, and inclined jagged shapes fabricated by direct laser writing, suitable for low cost, mass fabrication. Inclined jagged micromixer exhibited the best performance with up to 40% improvement compared with the simple straight geometry. Deliberate geometrical modifications, exemplified here in a jagged micromixer on paper, cut the limit of detection (LOD) by at least half without impacting the linear detection range.
Collapse
Affiliation(s)
- Elham Mollaie
- School of Mechanical Engineering, Iran University of Science and Technology, Tehran, Iran
| | - Sasan Asiaei
- Sensors and Integrated Bio-Microfluidics/MEMS Laboratory, School of Mechanical Engineering, Iran University of Science and Technology, Tehran, Iran
| | - Hiwa Aryan
- School of Mechanical Engineering, Iran University of Science and Technology, Tehran, Iran
- Clinical Research Development Center of Imam Khomeini and Mohammad Kermanshahi and Farabi Hospitals, Kermanshah University of Medical Sciences, Kermanshah, Iran
| |
Collapse
|
18
|
Ma P, Wang S, Wang J, Wang Y, Dong Y, Li S, Su H, Chen P, Feng X, Li Y, Du W, Liu BF. Rapid Assembly of Cellulose Microfibers into Translucent and Flexible Microfluidic Paper-Based Analytical Devices via Wettability Patterning. Anal Chem 2022; 94:13332-13341. [PMID: 36121740 DOI: 10.1021/acs.analchem.2c01424] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Microfluidic paper-based analytical devices (μPADs) are emerging as powerful analytical platforms in clinical diagnostics, food safety, and environmental protection because of their low cost and favorable substrate properties for biosensing. However, the existing top-down fabrication methods of paper-based chips suffer from low resolution (>200 μm). Additionally, papers have limitations in their physical properties (e.g., thickness, transmittance, and mechanical flexibility). Here, we demonstrate a bottom-up approach for the rapid fabrication of heterogeneously controlled paper-based chip arrays. We simply print a wax-patterned microchip with wettability contrasts, enabling automatic and selective assembly of cellulose microfibers to construct predefined paper-based microchip arrays with controllable thickness. This paper-based microchip printing technology is feasible for various substrate materials ranging from inorganic glass to organic polymers, providing a versatile platform for the full range of applications including transparent devices and flexible health monitoring. Our bottom-up printing technology using cellulose microfibers as the starting material provides a lateral resolution down to 42 ± 3 μm and achieves the narrowest channel barrier down to 33 ± 2 μm. As a proof-of-concept demonstration, a flexible paper-based glucose monitor is built for human health care, requiring only 0.3 μL of sample for testing.
Collapse
Affiliation(s)
- Peng Ma
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan 430074, China
| | - Shanshan Wang
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan 430074, China.,BGI-Shenzhen, Shenzhen 518083, China
| | - Jie Wang
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan 430074, China
| | - Yu Wang
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan 430074, China
| | - Yue Dong
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan 430074, China
| | - Shunji Li
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan 430074, China
| | - Huiying Su
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan 430074, China.,School of Biological Engineering, Huainan Normal University, Huainan, Anhui 232038, China
| | - Peng Chen
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan 430074, China
| | - Xiaojun Feng
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan 430074, China
| | - Yiwei Li
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan 430074, China
| | - Wei Du
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan 430074, China
| | - Bi-Feng Liu
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan 430074, China
| |
Collapse
|
19
|
Wang H, Chen R, Zhang F, Yu Z, Wang Y, Tang Z, Yang L, Tang X, Xiong B. Superhydrophobic Paper-Based Microfluidic Field-Effect Transistor Biosensor Functionalized with Semiconducting Single-Walled Carbon Nanotube and DNAzyme for Hypocalcemia Diagnosis. Int J Mol Sci 2022; 23:ijms23147799. [PMID: 35887147 PMCID: PMC9318675 DOI: 10.3390/ijms23147799] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2022] [Revised: 07/05/2022] [Accepted: 07/07/2022] [Indexed: 02/06/2023] Open
Abstract
Hypocalcemia is caused by a sharp decline in blood calcium concentration after dairy cow calving, which can lead to various diseases or even death. It is necessary to develop an inexpensive, easy-to-operate, reliable sensor to diagnose hypocalcemia. The cellulose-paper-based microfluidic field-effect biosensor is promising for point-of-care, but it has poor mechanical strength and a short service life after exposure to an aqueous solution. Octadecyltrichlorosilane (OTS), as a popular organosilane derivative, can improve the hydrophobicity of cellulose paper to overcome the shortage of cellulose paper. In this work, OTS was used to produce the superhydrophobic cellulose paper that enhances the mechanical strength and short service life of MFB, and a microfluidic field-effect biosensor (MFB) with semiconducting single-walled carbon nanotubes (SWNTs) and DNAzyme was then developed for the Ca2+ determination. Pyrene carboxylic acid (PCA) attached to SWNTs through a non-covalent π-π stacking interaction provided a carboxyl group that can bond with an amino group of DNAzyme. Two DNAzymes with different sensitivities were designed by changing the sequence length and cleavage site, which were functionalized with SPFET/SWNTs-PCA to form Dual-MFB, decreasing the interference of impurities in cow blood. After optimizing the detecting parameters, Dual-MFB could determine the Ca2+ concentration in the range of 25 μM to 5 mM, with a detection limit of 10.7 μM. The proposed Dual-MFB was applied to measure Ca2+ concentration in cow blood, which provided a new method to diagnose hypocalcemia after dairy cow calving.
Collapse
Affiliation(s)
- Hui Wang
- State Key Laboratory of Animal Nutrition, Institute of Animal Science, Chinese Academy of Agricultural Sciences, Beijing 100193, China; (H.W.); (R.C.); (F.Z.); (Z.Y.); (Y.W.); (Z.T.); (L.Y.)
| | - Ruipeng Chen
- State Key Laboratory of Animal Nutrition, Institute of Animal Science, Chinese Academy of Agricultural Sciences, Beijing 100193, China; (H.W.); (R.C.); (F.Z.); (Z.Y.); (Y.W.); (Z.T.); (L.Y.)
| | - Fan Zhang
- State Key Laboratory of Animal Nutrition, Institute of Animal Science, Chinese Academy of Agricultural Sciences, Beijing 100193, China; (H.W.); (R.C.); (F.Z.); (Z.Y.); (Y.W.); (Z.T.); (L.Y.)
- State Key Laboratory of Animal Nutrition, College of Animal Science and Technology, China Agricultural University, Beijing 100193, China
| | - Zhixue Yu
- State Key Laboratory of Animal Nutrition, Institute of Animal Science, Chinese Academy of Agricultural Sciences, Beijing 100193, China; (H.W.); (R.C.); (F.Z.); (Z.Y.); (Y.W.); (Z.T.); (L.Y.)
| | - Yue Wang
- State Key Laboratory of Animal Nutrition, Institute of Animal Science, Chinese Academy of Agricultural Sciences, Beijing 100193, China; (H.W.); (R.C.); (F.Z.); (Z.Y.); (Y.W.); (Z.T.); (L.Y.)
| | - Zhonglin Tang
- State Key Laboratory of Animal Nutrition, Institute of Animal Science, Chinese Academy of Agricultural Sciences, Beijing 100193, China; (H.W.); (R.C.); (F.Z.); (Z.Y.); (Y.W.); (Z.T.); (L.Y.)
| | - Liang Yang
- State Key Laboratory of Animal Nutrition, Institute of Animal Science, Chinese Academy of Agricultural Sciences, Beijing 100193, China; (H.W.); (R.C.); (F.Z.); (Z.Y.); (Y.W.); (Z.T.); (L.Y.)
| | - Xiangfang Tang
- State Key Laboratory of Animal Nutrition, Institute of Animal Science, Chinese Academy of Agricultural Sciences, Beijing 100193, China; (H.W.); (R.C.); (F.Z.); (Z.Y.); (Y.W.); (Z.T.); (L.Y.)
- Correspondence: (X.T.); (B.X.)
| | - Benhai Xiong
- State Key Laboratory of Animal Nutrition, Institute of Animal Science, Chinese Academy of Agricultural Sciences, Beijing 100193, China; (H.W.); (R.C.); (F.Z.); (Z.Y.); (Y.W.); (Z.T.); (L.Y.)
- Correspondence: (X.T.); (B.X.)
| |
Collapse
|
20
|
Wang M, Cui J, Wang Y, Yang L, Jia Z, Gao C, Zhang H. Microfluidic Paper-Based Analytical Devices for the Determination of Food Contaminants: Developments and Applications. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY 2022; 70:8188-8206. [PMID: 35786878 DOI: 10.1021/acs.jafc.2c02366] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Food safety is an issue that cannot be ignored at any time because of the great impact of food contaminants on people's daily life, social production, and the economy. Because of the extensive demand for high-quality food, it is necessary to develop rapid, reliable, and efficient devices for food contaminant detection. Microfluidic paper-based analytical devices (μPADs) have been applied in a variety of detection fields owing to the advantages of low-cost, ease of handling, and portability. This review systematically discusses the latest progress of μPADs, including the fundamentals of fabrication as well as applications in the detection of chemical and biological hazards in foods, hoping to provide suitable screening strategies for contaminants in foods and accelerating the technology transformation of μPADs from the lab into the field.
Collapse
Affiliation(s)
- Minglu Wang
- Shandong Provincial Key Laboratory of Animal Resistance Biology, Key Laboratory of Food Nutrition and Safety of Shandong Normal University, College of Life Science, Shandong Normal University, Jinan 250014, PR China
| | - Jiarui Cui
- Shandong Provincial Key Laboratory of Animal Resistance Biology, Key Laboratory of Food Nutrition and Safety of Shandong Normal University, College of Life Science, Shandong Normal University, Jinan 250014, PR China
| | - Ying Wang
- College of Food Science and Engineering, Shandong Agricultural University, Tai'an 271018, PR China
| | - Liu Yang
- Shandong Provincial Key Laboratory of Animal Resistance Biology, Key Laboratory of Food Nutrition and Safety of Shandong Normal University, College of Life Science, Shandong Normal University, Jinan 250014, PR China
| | - Zhenzhen Jia
- Shandong Provincial Key Laboratory of Animal Resistance Biology, Key Laboratory of Food Nutrition and Safety of Shandong Normal University, College of Life Science, Shandong Normal University, Jinan 250014, PR China
| | - Chuanjie Gao
- Shandong Province Institute for the Control of Agrochemicals, Jinan, 250131, PR China
| | - Hongyan Zhang
- Shandong Provincial Key Laboratory of Animal Resistance Biology, Key Laboratory of Food Nutrition and Safety of Shandong Normal University, College of Life Science, Shandong Normal University, Jinan 250014, PR China
| |
Collapse
|
21
|
Wang G, Cheng J, Ma J, Huang S, Zhang T, Li Y, Li H. Preparation and application of an olfactory visualization freshness sensor array based on microfluid paper‐based chip. J FOOD PROCESS PRES 2022. [DOI: 10.1111/jfpp.16530] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- Guannan Wang
- School of Printing and Packaging Wuhan University Wuhan China
| | - Jiawei Cheng
- School of Printing and Packaging Wuhan University Wuhan China
| | - Jun Ma
- School of Printing and Packaging Wuhan University Wuhan China
| | - Shaoyun Huang
- Department of Graphic Information Processing Jingchu University of Technology Jingmen China
| | - Tao Zhang
- School of Printing and Packaging Wuhan University Wuhan China
| | - Yanwei Li
- School of Printing and Packaging Wuhan University Wuhan China
| | - Houbin Li
- School of Printing and Packaging Wuhan University Wuhan China
| |
Collapse
|
22
|
Selvakumar B, Kathiravan A. Sensory materials for microfluidic paper based analytical devices - A review. Talanta 2021; 235:122733. [PMID: 34517601 DOI: 10.1016/j.talanta.2021.122733] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2021] [Revised: 07/18/2021] [Accepted: 07/23/2021] [Indexed: 11/17/2022]
Abstract
The microfluidic paper-based analytical devices (μPADs) have grown-up swiftly over the decade due to its low cost, simple fabrication procedure, resource-limitedness, non-toxicity and their environmentally benign nature. The μPADs, also identified as point-of-care devices or health care devices have successfully applied in several fields such as diagnostics, biological, food safety, environmental, electrochemical and most importantly colorimetric/fluorimetric sensors, owing to the attractive passive motions of analyte without any external forces. In recent years, a large number of colorimetric and fluorimetric probes have been reported that can selectively recognize the analytes in μPADs. However, there is no organized review on its structure-activity relationship. In this review, we have focused to summarize the colorimetric and fluorimetric probes utilized in μPADs. This review discuss about the relationships between the structure and functions of various probes as signaling units of the efficient μPADs. The probes including nanomaterials, nanozymes, polymers and organic molecules, their structural activity with regard to sensing performances along with their limit of detection are also discussed. This review is expected to assist readers for better understanding of the sensing mechanisms of various chemo and bio-probes utilized in μPADs, as well as promote their advancement in the field. On the other hand, this review also helps the researchers for enhancement of μPADs and paves way for synergistic application of existing molecular probes as an effective diagnostic tool for the worldwide pandemic novel corona virus COVID-19.
Collapse
Affiliation(s)
- Bhavadharini Selvakumar
- Department of Chemistry, Vel Tech Rangarajan Dr Sagunthala R & D Institute of Science and Technology, Avadi, Chennai, 600 062, Tamil Nadu, India
| | - Arunkumar Kathiravan
- Department of Chemistry, Vel Tech Rangarajan Dr Sagunthala R & D Institute of Science and Technology, Avadi, Chennai, 600 062, Tamil Nadu, India.
| |
Collapse
|
23
|
Ozer T, Henry CS. Paper-based analytical devices for virus detection: Recent strategies for current and future pandemics. Trends Analyt Chem 2021; 144:116424. [PMID: 34462612 PMCID: PMC8387141 DOI: 10.1016/j.trac.2021.116424] [Citation(s) in RCA: 29] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Abstract
The importance of user-friendly, inexpensive, sensitive, and selective detection of viruses has been highlighted again due to the recent Coronavirus disease 2019 (COVID-19) pandemic. Among the analytical tools, paper-based devices (PADs) have become a leading alternative for point-of-care (POC) testing. In this review, we discuss the recent development strategies and applications in nucleic acid-based, antibody/antigen-based and other affinity-based PADs using optical and electrochemical detection methods for sensing viruses. In addition, advantages and drawbacks of presented PADs are identified. Current state and insights towards future perspectives are presented regarding developing POC diagnosis platform for COVID-19. This review considers state-of-the-art technologies for further development and improvement in PADs performance for virus detection.
Collapse
Affiliation(s)
- Tugba Ozer
- Yildiz Technical University, Faculty of Chemical-Metallurgical Engineering, Department of Bioengineering, 34220, Istanbul, Turkey
| | - Charles S Henry
- Colorado State University, Department of Chemistry, Fort Collins, CO, 80523, USA
- Colorado State University, School of Biomedical Engineering, Fort Collins, CO, 80523, USA
| |
Collapse
|
24
|
Qin X, Liu J, Zhang Z, Li J, Yuan L, Zhang Z, Chen L. Microfluidic paper-based chips in rapid detection: Current status, challenges, and perspectives. Trends Analyt Chem 2021. [DOI: 10.1016/j.trac.2021.116371] [Citation(s) in RCA: 47] [Impact Index Per Article: 15.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
|
25
|
[Applications of microfluidic paper-based chips in environmental analysis and detection]. Se Pu 2021; 39:802-815. [PMID: 34212581 PMCID: PMC9404056 DOI: 10.3724/sp.j.1123.2020.09004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
近年来,微流控纸芯片由于低成本、便携化、检测快等优点,在需要快速检测的环境分析领域中展现出了巨大的应用前景。该综述从微流控纸芯片在环境分析中的应用角度,总结归纳了微流控纸芯片在环境分析中的最新研究进展,并展望了其在未来的发展趋势与挑战。论文内容引用150余篇源于科学引文索引(SCI)与中文核心期刊中的相关论文。该综述包括微流控纸芯片在环境检测中的优势与制造方法介绍;电化学法、荧光法、比色法、表面增强拉曼法、集成传感法等基于纸芯片的先进分析方法介绍;根据环境分析目标物种类,如重金属离子、营养盐、农药、微生物、抗生素以及其他污染物等,对纸芯片的最新应用现状进行了举例评述;基于微流控纸芯片的环境分析研究的未来发展趋势和前景展望。通过综述近期相关研究,表明微流控纸芯片从提出至今虽然只有十几年的发展历程,但其在环境分析研究中的发展却十分迅速。微流控纸芯片可以根据不同的环境条件和检测要求灵活选择制作与分析方法,实现最佳的检测效果。但是微流控纸芯片也面临一些挑战,如纸张机械强度不足、流体控制程度不佳等问题。这些问题指出了微流控纸芯片在环境检测领域的发展趋势,相信随着不断深入的研究,纸芯片将会在未来的环境分析中发挥更大作用。
Collapse
|
26
|
Jiang N, Tansukawat ND, Gonzalez-Macia L, Ates HC, Dincer C, Güder F, Tasoglu S, Yetisen AK. Low-Cost Optical Assays for Point-of-Care Diagnosis in Resource-Limited Settings. ACS Sens 2021; 6:2108-2124. [PMID: 34076428 DOI: 10.1021/acssensors.1c00669] [Citation(s) in RCA: 43] [Impact Index Per Article: 14.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Readily deployable, low-cost point-of-care medical devices such as lateral flow assays (LFAs), microfluidic paper-based analytical devices (μPADs), and microfluidic thread-based analytical devices (μTADs) are urgently needed in resource-poor settings. Governed by the ASSURED criteria (affordable, sensitive, specific, user-friendly, rapid and robust, equipment-free, and deliverability) set by the World Health Organization, these reliable platforms can screen a myriad of chemical and biological analytes including viruses, bacteria, proteins, electrolytes, and narcotics. The Ebola epidemic in 2014 and the ongoing pandemic of SARS-CoV-2 have exemplified the ever-increasing importance of timely diagnostics to limit the spread of diseases. This review provides a comprehensive survey of LFAs, μPADs, and μTADs that can be deployed in resource-limited settings. The subsequent commercialization of these technologies will benefit the public health, especially in areas where access to healthcare is limited.
Collapse
Affiliation(s)
- Nan Jiang
- West China School of Basic Medical Sciences & Forensic Medicine, Sichuan University, Chengdu 610041, China
- Department of Chemical Engineering, Imperial College London, London SW7 2AZ, United Kingdom
| | - Natha Dean Tansukawat
- Department of Chemical Engineering, Imperial College London, London SW7 2AZ, United Kingdom
| | - Laura Gonzalez-Macia
- Department of Bioengineering, Imperial College London, London SW7 2AZ, United Kingdom
| | - H. Ceren Ates
- Freiburg Center for Interactive Materials and Bioinspired Technologies (FIT), University of Freiburg, Freiburg 79110, Germany
- Department of Microsystems Engineering (IMTEK), Laboratory for Sensors, University of Freiburg, Freiburg 79110, Germany
| | - Can Dincer
- Freiburg Center for Interactive Materials and Bioinspired Technologies (FIT), University of Freiburg, Freiburg 79110, Germany
- Department of Microsystems Engineering (IMTEK), Laboratory for Sensors, University of Freiburg, Freiburg 79110, Germany
| | - Firat Güder
- Department of Bioengineering, Imperial College London, London SW7 2AZ, United Kingdom
| | - Savas Tasoglu
- Department of Mechanical Engineering, Koc University, Sariyer, Istanbul 34450, Turkey
| | - Ali K. Yetisen
- Department of Chemical Engineering, Imperial College London, London SW7 2AZ, United Kingdom
| |
Collapse
|
27
|
Singhal HR, Prabhu A, Giri Nandagopal M, Dheivasigamani T, Mani NK. One-dollar microfluidic paper-based analytical devices: Do-It-Yourself approaches. Microchem J 2021. [DOI: 10.1016/j.microc.2021.106126] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
28
|
Mavaei M, Chahardoli A, Fattahi A, Khoshroo A. A Simple Method for Developing a Hand-Drawn Paper-Based Sensor for Mercury; Using Green Synthesized Silver Nanoparticles and Smartphone as a Hand-Held-Device for Colorimetric Assay. GLOBAL CHALLENGES (HOBOKEN, NJ) 2021; 5:2000099. [PMID: 33854790 PMCID: PMC8025396 DOI: 10.1002/gch2.202000099] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/04/2020] [Revised: 01/18/2021] [Indexed: 06/12/2023]
Abstract
Mercury ions are highly toxic at trace levels, and its pollution has posed a significant threat to the environment and public health, where current detection methods mainly require laborious operation and expensive instrumentation. Herein, a simple, cost-effective, instrument-free approach for selective detection of Hg2+ based on a hand-drawn paper-based naked-eye colorimetric device is developed. To develop a hand-drawn paper-based device, a crayon is used to build hydrophobic barriers and a paper puncher is applied to obtain patterns as a sensing zone. A green method for the synthesis of silver nanoparticles (AgNPs) is applied using Achillea Wilhelmsii (Aw) extract. The sensing ability of Aw-AgNPs toward Hg2+ is investigated in both solution-phase and paper substrate loaded with Aw-AgNPs using colorimetric methods. For the paper-based sensor, the quantification of the target relies on the visual readout of a color-changed sensing zone modified with Aw-AgNPs. Under optimal conditions, the color of Aw-AgNPs in aqueous solution and on the coated paper substrate can change from brown to colorless upon addition of target, with a detection limit of 28 × 10-9 m and 0.30 × 10-6 m, respectively. In conclusion, the present study indicates the potential of this hand-drawn eco-friendly paper-based sensor for monitoring of mercury.
Collapse
Affiliation(s)
- Maryamosadat Mavaei
- Pharmaceutical Sciences Research CenterHealth instituteKermanshah University of Medical SciencesKermanshah6715847141Iran
| | - Azam Chahardoli
- Pharmaceutical Sciences Research CenterHealth instituteKermanshah University of Medical SciencesKermanshah6715847141Iran
| | - Ali Fattahi
- Pharmaceutical Sciences Research CenterHealth instituteKermanshah University of Medical SciencesKermanshah6715847141Iran
- Medical Biology Research CenterKermanshah University of Medical SciencesKermanshah6715847141Iran
- Present address:
Center for Applied NanoBioscience and MedicineCollege of Medicine PhoenixUniversity of ArizonaPhoenixAZUnited States
| | - Alireza Khoshroo
- Pharmaceutical Sciences Research CenterHealth instituteKermanshah University of Medical SciencesKermanshah6715847141Iran
| |
Collapse
|
29
|
Samara B, Deliorman M, Sukumar P, Qasaimeh MA. Cryopreservable arrays of paper-based 3D tumor models for high throughput drug screening. LAB ON A CHIP 2021; 21:844-854. [PMID: 33615319 DOI: 10.1039/d0lc01300e] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
Three-dimensional (3D) tumor models have gained increased attention in life-science applications as they better represent physiological conditions of in vivo tumor microenvironments, and thus, possess big potential for guiding drug screening studies. Although various techniques proved effective in growing cancer cells in 3D, their procedures are typically complex, time consuming, and expensive. Here, we present a versatile, robust, and cost-effective method that utilizes a paper platform to create cryopreservable high throughput arrays of 3D tumor models. In the approach, we use custom 3D printed masks along with simple chemistry modifications to engineer highly localized hydrophilic 'virtual microwells', or microspots, on paper for 3D cell aggregation, surrounded by hydrophobic barriers that prevent inter-microspot mixing. The method supports the formation and cryopreservation of 3D tumor arrays for extended periods of storage time. Using MCF-7 and MDA-MB-231 breast cancer cell lines, we show that the cryopreservable arrays of paper-based 3D models are effective in studying tumor response to cisplatin drug treatment, while replicating key characteristics of the in vivo tumors that are absent in conventional 2D cultures. This technology offers a low cost, easy, and fast experimental procedure, and allows for 3D tumor arrays to be cryopreserved and thawed for on-demand use. This could potentially provide unparalleled advantages to the fields of tissue engineering and personalized medicine.
Collapse
Affiliation(s)
- Bisan Samara
- Division of Engineering, New York University Abu Dhabi (NYUAD), Abu Dhabi, 129188 United Arab Emirates.
| | - Muhammedin Deliorman
- Division of Engineering, New York University Abu Dhabi (NYUAD), Abu Dhabi, 129188 United Arab Emirates.
| | - Pavithra Sukumar
- Division of Engineering, New York University Abu Dhabi (NYUAD), Abu Dhabi, 129188 United Arab Emirates.
| | - Mohammad A Qasaimeh
- Division of Engineering, New York University Abu Dhabi (NYUAD), Abu Dhabi, 129188 United Arab Emirates. and Department of Mechanical and Aerospace Engineering, New York University, Brooklyn, NY, 11201 USA
| |
Collapse
|
30
|
Dabbagh SR, Becher E, Ghaderinezhad F, Havlucu H, Ozcan O, Ozkan M, Yetisen AK, Tasoglu S. Increasing the packing density of assays in paper-based microfluidic devices. BIOMICROFLUIDICS 2021; 15:011502. [PMID: 33569089 PMCID: PMC7864678 DOI: 10.1063/5.0042816] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/05/2021] [Accepted: 01/07/2021] [Indexed: 05/04/2023]
Abstract
Paper-based devices have a wide range of applications in point-of-care diagnostics, environmental analysis, and food monitoring. Paper-based devices can be deployed to resource-limited countries and remote settings in developed countries. Paper-based point-of-care devices can provide access to diagnostic assays without significant user training to perform the tests accurately and timely. The market penetration of paper-based assays requires decreased device fabrication costs, including larger packing density of assays (i.e., closely packed features) and minimization of assay reagents. In this review, we discuss fabrication methods that allow for increasing packing density and generating closely packed features in paper-based devices. To ensure that the paper-based device is low-cost, advanced fabrication methods have been developed for the mass production of closely packed assays. These emerging methods will enable minimizing the volume of required samples (e.g., liquid biopsies) and reagents in paper-based microfluidic devices.
Collapse
Affiliation(s)
| | - Elaina Becher
- Department of Biomedical Engineering, University of Connecticut, Storrs, Connecticut 06269, USA
| | - Fariba Ghaderinezhad
- Department of Mechanical Engineering, University of Connecticut, Storrs, Connecticut 06269, USA
| | - Hayati Havlucu
- Koç University Arçelik Research Center for Creative Industries (KUAR), Koç University, Sariyer, Istanbul 34450, Turkey
| | - Oguzhan Ozcan
- Koç University Arçelik Research Center for Creative Industries (KUAR), Koç University, Sariyer, Istanbul 34450, Turkey
| | - Mehmed Ozkan
- Boğaziçi Institute of Biomedical Engineering, Boğaziçi University, Çengelköy, Istanbul 34684, Turkey
| | - Ali Kemal Yetisen
- Department of Chemical Engineering, Imperial College London, London SW7 2AZ, United Kingdom
| | | |
Collapse
|
31
|
Hiep DH, Tanaka Y, Matsubara H, Ishizaka S. Fabrication of Paper-based Microfluidic Devices Using a Laser Beam Scanning Technique. ANAL SCI 2020; 36:1275-1278. [PMID: 32565528 DOI: 10.2116/analsci.20p196] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
This paper describes a novel method for fabricating paper-based microfluidic devices using a laser beam scanning technique. Cellulose chromatography papers were treated with octadecyltrichlorosilane (OTS) to make them entirely hydrophobic. A photoacid generator (CPI-410S) was soaked into the paper, and irradiated with a 405-nm laser beam to induce acid generating reactions. Since the silyl ether bond between cellulose and OTS was cleaved by the hydrolysis reaction, the photo-irradiated area changed to hydrophilic. By scanning the laser beam using a Galvo mirror system, arbitrary shaped hydrophilic patterns were successfully created on the paper in 50 μm resolution. To the best of our knowledge, this is the first report on the fabrication of hydrophilic channels on the OTS-treated paper using photo-induced acid generation processes coupled with the laser beam scanning technique. Quantification of nitrite was demonstrated with the paper device made by this method.
Collapse
Affiliation(s)
- Dang Huy Hiep
- Department of Chemistry, Graduate School of Science, Hiroshima University
| | - Yuta Tanaka
- Department of Chemistry, Graduate School of Science, Hiroshima University
| | - Hiroki Matsubara
- Graduate School of Advanced Science and Engineering, Hiroshima University
| | - Shoji Ishizaka
- Graduate School of Advanced Science and Engineering, Hiroshima University
| |
Collapse
|
32
|
Rossini EL, Kulyk DS, Ansu-Gyeabourh E, Sahraeian T, Pezza HR, Badu-Tawiah AK. Direct Analysis of Doping Agents in Raw Urine Using Hydrophobic Paper Spray Mass Spectrometry. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2020; 31:1212-1222. [PMID: 32357004 PMCID: PMC7891915 DOI: 10.1021/jasms.0c00063] [Citation(s) in RCA: 29] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
In this study, the direct analysis of doping agents in urine samples with no sample preparation by a modified paper spray mass spectrometry (PS-MS) methodology has been demonstrated for the first time. We have described a paper surface treatment with trichloromethylsilane using a gas-phase reaction to increase the ionization of target compounds. This approach was applied for the analysis of two classes of banned substances in urine samples: anabolic agents (trenbolone and clenbuterol) and diuretics (furosemide and hydrochlorothiazide). Under optimized conditions, the developed methods presented satisfactory repeatability, and an analysis of variance showed linearity without lack-of-fit. Highly sensitive detections as low as sub-nanogram per milliliter levels, which is below the minimum required performance levels proposed by the World Anti-Doping Agency, have been reached using the hydrophobic PS-MS analysis without any preconcentration and cleanup step.
Collapse
Affiliation(s)
- Eduardo Luiz Rossini
- Department of Chemistry and Biochemistry, The Ohio State University, 100 W. 18th Avenue, Columbus, Ohio 43210, United States
- Institute of Chemistry, Department of Analytical Chemistry, UNESP - São Paulo State University, R. Prof. Francisco Degni 55, P.O. Box 355, 14800-900, Araraquara, SP, Brazil
| | - Dmytro S. Kulyk
- Department of Chemistry and Biochemistry, The Ohio State University, 100 W. 18th Avenue, Columbus, Ohio 43210, United States
| | - Emelia Ansu-Gyeabourh
- Department of Chemistry and Biochemistry, The Ohio State University, 100 W. 18th Avenue, Columbus, Ohio 43210, United States
| | - Taghi Sahraeian
- Department of Chemistry and Biochemistry, The Ohio State University, 100 W. 18th Avenue, Columbus, Ohio 43210, United States
| | - Helena Redigolo Pezza
- Institute of Chemistry, Department of Analytical Chemistry, UNESP - São Paulo State University, R. Prof. Francisco Degni 55, P.O. Box 355, 14800-900, Araraquara, SP, Brazil
| | - Abraham K. Badu-Tawiah
- Department of Chemistry and Biochemistry, The Ohio State University, 100 W. 18th Avenue, Columbus, Ohio 43210, United States
| |
Collapse
|
33
|
|
34
|
Zhou W, Feng M, Valadez A, Li X. One-Step Surface Modification to Graft DNA Codes on Paper: The Method, Mechanism, and Its Application. Anal Chem 2020; 92:7045-7053. [PMID: 32207965 DOI: 10.1021/acs.analchem.0c00317] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Abstract
Glass slides have been widely used for DNA immobilization in DNA microarray and numerous bioassays for decades, whereas they are faced with limitations of low probe density, time-consuming modification steps, and expensive instruments. In this work, a simple one-step surface modification method using 3-aminopropyl trimethoxysilane (APTMS) has been developed and applied to graft DNA codes on paper. Higher DNA immobilization efficiency was obtained in comparison with that in a conventional method using glass slides. Fluorescence detection, X-ray photoelectron spectroscopy (XPS), infrared spectra (FT-IR), and pH influence studies were employed to characterize the surface modification and subsequent DNA immobilization, which further reveals a mechanism in which this method lies in ionic interactions between the positively charged APTMS-modified paper surface and negatively charged DNA probes. Furthermore, an APTMS-modified paper-based device has been developed to demonstrate application in low-cost detection of a foodborne pathogen, Giardia lamblia, with high sensitivity (the detection limit of 22 nM) and high specificity. Compared with conventional methods using redundant cross-linking reactions, our method is simpler, faster, versatile, and lower-cost, enabling broad applications of paper-based bioassays especially for point-of-care detection in resource-poor settings.
Collapse
Affiliation(s)
- Wan Zhou
- Department of Chemistry and Biochemistry, The University of Texas at El Paso, 500 West University Avenue, El Paso, Texas 79968, United States
| | - Mengli Feng
- Department of Chemistry and Biochemistry, The University of Texas at El Paso, 500 West University Avenue, El Paso, Texas 79968, United States
| | - Alejandra Valadez
- Department of Chemistry and Biochemistry, The University of Texas at El Paso, 500 West University Avenue, El Paso, Texas 79968, United States
| | - XiuJun Li
- Department of Chemistry and Biochemistry, The University of Texas at El Paso, 500 West University Avenue, El Paso, Texas 79968, United States.,Biomedical Engineering, The University of Texas at El Paso, 500 West University Avenue, El Paso, Texas 79968, United States.,Border Biomedical Research Center, The University of Texas at El Paso, 500 West University Avenue, El Paso, Texas 79968, United States.,Environmental Science and Engineering, The University of Texas at El Paso, 500 West University Avenue, El Paso, Texas 79968, United States
| |
Collapse
|
35
|
Puiu M, Bala C. Microfluidics-integrated biosensing platforms as emergency tools for on-site field detection of foodborne pathogens. Trends Analyt Chem 2020. [DOI: 10.1016/j.trac.2020.115831] [Citation(s) in RCA: 31] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
|
36
|
A Flexible Method for Nanofiber-based 3D Microfluidic Device Fabrication for Water Quality Monitoring. MICROMACHINES 2020; 11:mi11030276. [PMID: 32155922 PMCID: PMC7143371 DOI: 10.3390/mi11030276] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/20/2020] [Revised: 03/03/2020] [Accepted: 03/05/2020] [Indexed: 12/13/2022]
Abstract
Water pollution seriously affects human health. Accurate and rapid detection and timely treatment of toxic substances in water are urgently needed. A stacked multilayer electrostatic printing technique was developed for making nanofiber-based microfluidic chips for water-quality testing. Nanofiber membrane matrix structures for microfluidic devices were fabricated by electrospinning. A hydrophobic barrier was then printed through electrostatic wax printing. This process was repeatedly performed to create three-dimensional nanofiber-based microfluidic analysis devices (3D-µNMADs). Flexible printing enabled one-step fabrication without the need for additional alignment or adhesive bonding. Practical applications of 3D-µNMADs include a colorimetric platform to quantitatively detect iron ion concentrations in water. There is also great potential for personalized point-of-care testing. Overall, the devices offer simple fabrication processes, flexible prototyping, potential for mass production, and multi-material integration.
Collapse
|
37
|
Zuo Y, Zheng L, Zhao C, Liu H. Micro-/Nanostructured Interface for Liquid Manipulation and Its Applications. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2020; 16:e1903849. [PMID: 31482672 DOI: 10.1002/smll.201903849] [Citation(s) in RCA: 34] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/18/2019] [Revised: 08/12/2019] [Indexed: 05/09/2023]
Abstract
Understanding the relationship between liquid manipulation and micro-/nanostructured interfaces has gained much attention due to the wide potential applications in many fields, such as chemical and biomedical assays, environmental protection, industry, and even daily life. Much work has been done to construct various materials with interfacial liquid manipulation abilities, leading to a range of interesting applications. Herein, different fabrication methods from the top-down approach to the bottom-up approach and subsequent surface modifications of micro-/nanostructured interfaces are first introduced. Then, interactions between the surface and liquid, including liquid wetting, liquid transportation, and a number of corresponding models, together with the definition of hydrophilic/hydrophobic, oleophilic/olephobic, the definition and mechanism of superwetting, including superhydrophobicity, superhydrophilicity, and superoleophobicity, are presented. The micro-/nanostructured interface, with major applications in self-cleaning, antifogging, anti-icing, anticorrosion, drag-reduction, oil-water separation, water collection, droplet (micro)array, and surface-directed liquid transport, is summarized, and the mechanisms underlying each application are discussed. Finally, the remaining challenges and future perspectives in this area are included.
Collapse
Affiliation(s)
- Yinxiu Zuo
- State Key Laboratory of Bioelectronics, School of Biological Science and Medical Engineering, Southeast University, Nanjing, 210096, China
| | - Liuzheng Zheng
- State Key Laboratory of Bioelectronics, School of Biological Science and Medical Engineering, Southeast University, Nanjing, 210096, China
| | - Chao Zhao
- State Key Laboratory of Bioelectronics, School of Biological Science and Medical Engineering, Southeast University, Nanjing, 210096, China
| | - Hong Liu
- State Key Laboratory of Bioelectronics, School of Biological Science and Medical Engineering, Southeast University, Nanjing, 210096, China
| |
Collapse
|
38
|
Smartphone-imaged multilayered paper-based analytical device for colorimetric analysis of carcinoembryonic antigen. Anal Bioanal Chem 2020; 412:2517-2528. [PMID: 32067065 DOI: 10.1007/s00216-020-02475-1] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2019] [Revised: 01/13/2020] [Accepted: 01/30/2020] [Indexed: 01/06/2023]
Abstract
Paper-based immunoassays are effective methods that employ microfluidic paper-based analytical devices (μPADs) for the rapid, simple, and accurate quantification of analytes in point-of-care diagnosis. In this study, we developed a wax-printed multilayered μPAD for the colorimetric detection of carcinoembryonic antigen (CEA), where the device contained a movable and rotatable detection layer to allow the μPAD to switch the state of the sample solutions, i.e., flowing or storing in the sensing zones. A smartphone with a custom-developed program served as an automated colorimetric reader to capture and analyze images from the μPAD, before calculating and displaying the test results. After optimizing the crucial conditions for the assay, the proposed method exhibited a wide linear dynamic range from 0.5 to 70 ng/mL, with a low CEA detection limit of 0.015 ng/mL. The clinical performance of this method was successfully validated using 50 positive and 40 negative human serum samples, thereby demonstrating the high sensitivity of 98.0% and specificity of 97.5% in the detection of CEA. The proposed method is greatly simplified compared with the cumbersome steps required for traditional immunoassays, but without any loss of accuracy and stability, as well as reducing the time needed to detect CEA. Complex and bulky instruments are replaced with a smartphone. The proposed detection platform could potentially be applied in point-of-care testing. Graphical abstract.
Collapse
|
39
|
Zhang L, Chen KS, Yu HZ. Superhydrophobic Glass Microfiber Filter as Background-Free Substrate for Quantitative Fluorometric Assays. ACS APPLIED MATERIALS & INTERFACES 2020; 12:7665-7672. [PMID: 31957427 DOI: 10.1021/acsami.9b17432] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
We have discovered herein that commonly used laboratory glass microfiber filters can be functionalized as background-free superhydrophobic substrates for quantitative fluorometric assays. In particular, glass microfiber filters (Whatman GF/A) can be treated with low-concentration (20 mM) methyltrichlorosilane/toluene solution to be superhydrophobic (water contact angle >150°) in less than 5 min; the modified glass microfiber filter can be readily patterned with UV/ozone irradiation to create hydrophilic reaction zones on the otherwise superhydrophobic substrate. Compared with traditional cellulose filter paper, the glass microfiber filter has extremely low fluorescence background, which makes it an excellent substrate for preparing quantitative fluorometric assays. In conjunction with smartphone imaging and color analysis, we have showcased a copper(I)-catalyzed azide-alkyne cycloaddition (CuAAC)-based fluorometric assay for copper quantitation on these patterned, superhydrophobic glass microfiber filter substrates. Both the limit of detection and linear response range are comparable with the standard spectrophotometric quantitation in solution and commercial copper detection kits, which augments the application potential of superhydrophobic glass microfiber filters as ideal (e.g., background-free) substrates for the preparation of multiplex microassays and other advanced microanalytical devices based on fluorescence readout.
Collapse
Affiliation(s)
- Lishen Zhang
- Department of Chemistry and 4D Labs , Simon Fraser University , Burnaby , British Columbia V5A 1S6 , Canada
| | - Kennedy S Chen
- Department of Chemistry and 4D Labs , Simon Fraser University , Burnaby , British Columbia V5A 1S6 , Canada
| | - Hua-Zhong Yu
- Department of Chemistry and 4D Labs , Simon Fraser University , Burnaby , British Columbia V5A 1S6 , Canada
| |
Collapse
|
40
|
Almasvandi Z, Vahidinia A, Heshmati A, Zangeneh MM, Goicoechea HC, Jalalvand AR. Coupling of digital image processing and three-way calibration to assist a paper-based sensor for determination of nitrite in food samples. RSC Adv 2020; 10:14422-14430. [PMID: 35498492 PMCID: PMC9051906 DOI: 10.1039/c9ra10918h] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/25/2019] [Accepted: 04/01/2020] [Indexed: 12/24/2022] Open
Abstract
In this work, a novel and very interesting analytical methodology based on coupling of digital image processing and three-way calibration has been developed for determination of nitrite in food samples.
Collapse
Affiliation(s)
- Zohreh Almasvandi
- Department of Nutrition and Food Hygiene
- School of Medicine
- Hamadan University of Medical Sciences
- Hamadan
- Iran
| | - Ali Vahidinia
- Department of Nutrition and Food Hygiene
- School of Medicine
- Hamadan University of Medical Sciences
- Hamadan
- Iran
| | - Ali Heshmati
- Department of Nutrition and Food Hygiene
- School of Medicine
- Hamadan University of Medical Sciences
- Hamadan
- Iran
| | | | - Hector C. Goicoechea
- Laboratorio de Desarrollo Analítico y Quimiometría (LADAQ)
- Catedra de Química Analítica I
- Universidad Nacional del Litoral
- Ciudad Universitaria
- Santa Fe
| | - Ali R. Jalalvand
- Research Center of Oils and Fats
- Kermanshah University of Medical Sciences
- Kermanshah
- Iran
| |
Collapse
|
41
|
Guan Y, Sun B. Detection and extraction of heavy metal ions using paper-based analytical devices fabricated via atom stamp printing. MICROSYSTEMS & NANOENGINEERING 2020; 6:14. [PMID: 34567629 PMCID: PMC8433178 DOI: 10.1038/s41378-019-0123-9] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/26/2019] [Revised: 10/24/2019] [Accepted: 11/04/2019] [Indexed: 05/23/2023]
Abstract
As a promising concept, microfluidic paper-based analytical devices (μPADs) have seen rapid development in recent years. In this study, a new method of fabricating μPADs by atom stamp printing (ASP) is proposed and studied. The advantages of this new method compared to other methods include its low cost, ease of operation, high production efficiency, and high resolution (the minimum widths of the hydrophilic channels and hydrophobic barriers are 328 and 312 μm, respectively). As a proof of concept, μPADs fabricated with the ASP method were used to detect different concentrations of Cu2+ via a colorimetric method. Moreover, combined with a distance-based detection method, these devices achieved a Cu2+ detection limit of down to 1 mg/L. In addition, a new paper-based solid-liquid extraction device (PSED) based on a three-dimensional (3D) μPAD with a "3 + 2" structure and a recyclable extraction mode was developed. Specifically, using the characteristics of paper filtration and capillary force, the device completed multiple extraction and filtration steps from traditional solid-liquid extraction processes with high efficiency. The developed PSED platform allows the detection of heavy metal ions much more cheaply and simply and with a faster response time at the point of care, and it has great promise for applications in food safety and environmental pollution in resource-limited areas.
Collapse
Affiliation(s)
- Yanfang Guan
- School of Electromechanical Engineering, Henan University of technology, Zhengzhou, 450001 China
| | - Baichuan Sun
- School of Electromechanical Engineering, Henan University of technology, Zhengzhou, 450001 China
| |
Collapse
|
42
|
Guo X, Guo Y, Liu W, Chen Y, Chu W. Fabrication of paper-based microfluidic device by recycling foamed plastic and the application for multiplexed measurement of biomarkers. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2019; 223:117341. [PMID: 31319269 DOI: 10.1016/j.saa.2019.117341] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/24/2018] [Revised: 07/03/2019] [Accepted: 07/07/2019] [Indexed: 05/14/2023]
Abstract
Microfluidic paper-based analytical devices (μPADs) are emerging as effective analytical platforms for point-of-care assays in resource-limited areas. Simple and cost-effective fabrication method still remains challenging on μPADs. A simple and cost-effective method for fabricating paper-based devices was presented in this work by using of dipping strategy with the recycled polystyrene in chloroform as the hydrophobic reagent. Adhesive tape was employed as mask to transfer the hydrophilic channel pattern to the paper substrate. With the single-sided adhesive tape stuck on the hydrophilic parts of the paper surface, the paper-based device was immersed in chloroform solution with dissolving recycling polystyrene for several seconds. Then the hydrophilic pattern can be achieved and all the other parts on the paper surface were hydrophobic. The adhesive tape was torn off from the hydrophilic parts. The highest contact angle value of 114° of the hydrophobic part was acquired with this simple fabrication method. By using of the sandwich-type immunoreactions and luminol-H2O2p-iodophenol (PIP) chemiluminescence(CL) system, three cancer biomarkers were simultaneously detected in human serum samples on μPADs with the linear range of 0.05-80.0 ng·mL-1 for carcinoembryonic antigen (CEA), 5.0-80.0 ng·mL-1 for alpha-fetal protein (AFP) and 1.0-50.0 ng·mL-1 for prostate-specific antigen (PSA). The fabricating strategy with recycling polystyrene and adhesive tape provides a versatile platform for prototyping of μPADs in both developed and resource constrained region.
Collapse
Affiliation(s)
- Xiaoyan Guo
- Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi'an 710062, PR China
| | - Yumei Guo
- Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi'an 710062, PR China
| | - Wei Liu
- Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi'an 710062, PR China.
| | - Ying Chen
- Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi'an 710062, PR China
| | - Weiru Chu
- Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi'an 710062, PR China
| |
Collapse
|
43
|
An S, Liu S, Cao J, Lu S. Nitrogen-Activated Oxidation in Nitrogen Direct Analysis in Real Time Mass Spectrometry (DART-MS) and Rapid Detection of Explosives Using Thermal Desorption DART-MS. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2019; 30:2092-2100. [PMID: 31368004 DOI: 10.1007/s13361-019-02279-3] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/22/2019] [Revised: 06/20/2019] [Accepted: 06/25/2019] [Indexed: 06/10/2023]
Abstract
Direct analysis in real time mass spectrometry (DART-MS) was used to analyze an array of explosives including nitro-based explosives, peroxide explosives, and energetic heterocyclic compounds with different DART discharge gases (helium, argon, and nitrogen). Profound analyte oxidation was observed for particular compounds (TNT (9) and 2, 4-DNT (10)), whose mass spectra were completely dominated by the oxidation products when nitrogen was substituted for helium in DART analysis. This interesting phenomenon suggested that a highly oxidative environment provided by N2 DART ion source. A possible mechanism involved in nitrogen DART was proposed which may help further understanding the different chemistry involved in the ionization process. This work also presents a thermal desorption DART (TD-DART) configuration that can enable rapid, specific analysis of explosives from swipes. The screening of swipes with three different compositions (fiberglass, Hybond N+ membrane, and filter paper) showed that fiberglass swipe has the best performance which was then used for the subsequent TD-DART analysis. A direct comparison of TD-DART with traditional DART demonstrated that TD-DART indeed gives better response than traditional DART (provided that the distance between the DART source and mass spectrometer is the same) and will have wider applications than traditional DART.
Collapse
Affiliation(s)
- ShuQi An
- Key Laboratory of Cluster Science, Ministry of Education of China; Beijing Key Laboratory of Photoelectronic/Electrophotonic Conversion Materials; School of Chemistry, Beijing Institute of Technology, Beijing, 100081, China
| | - Shuai Liu
- Key Laboratory of Cluster Science, Ministry of Education of China; Beijing Key Laboratory of Photoelectronic/Electrophotonic Conversion Materials; School of Chemistry, Beijing Institute of Technology, Beijing, 100081, China
| | - Jie Cao
- Key Laboratory of Cluster Science, Ministry of Education of China; Beijing Key Laboratory of Photoelectronic/Electrophotonic Conversion Materials; School of Chemistry, Beijing Institute of Technology, Beijing, 100081, China.
| | - ShiFang Lu
- Key Laboratory of Cluster Science, Ministry of Education of China; Beijing Key Laboratory of Photoelectronic/Electrophotonic Conversion Materials; School of Chemistry, Beijing Institute of Technology, Beijing, 100081, China
| |
Collapse
|
44
|
Wang C, Fang H, Qi X, Hang C, Sun Y, Peng Z, Wei W, Wang Y. Silk fibroin film-coated MgZnCa alloy with enhanced in vitro and in vivo performance prepared using surface activation. Acta Biomater 2019; 91:99-111. [PMID: 31028907 DOI: 10.1016/j.actbio.2019.04.048] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2018] [Revised: 04/11/2019] [Accepted: 04/22/2019] [Indexed: 10/26/2022]
Abstract
Magnesium and its alloys have generated considerable interest as one of the most promising biodegradable metals for biomedical bone implants. However, the enormous challenges are to improve their rapid corrosion excessively as well as to endow them with biocompatibility and biosafety. Herein, we introduce a natural silk fibroin protein coating to control the corrosion resistance and enhance the biocompatibility of MgZnCa alloy. To obtain a robust and reliable coated structure, different surface-activation processes are employed to increase the available functional groups on MgZnCa surfaces before coating. Compared to oxygen plasma activation, our unique vacuum ultraviolet-ozone (VUV/O3) activation method is effective in realizing uniform silk fibroin films as a protective barrier on MgZnCa alloy surfaces, and the nanoscratch test verified the superior adhesion strength of the silk fibroin-coated magnesium alloy structure. Long-term immersion results combined with electrochemical tests showed the preferable in vitro anticorrosion behavior and a low degradation rate of coated Mg alloy (1/8 times that of uncoated Mg alloy). Cell adhesion and cytotoxicity tests demonstrated that silk fibroin-coated MgZnCa presented improved biocompatibility with bone marrow mesenchymal stem cells. An animal study involving silk fibroin-coated MgZnCa implanted on one side of a rabbit spine for 180 days showed remarkably improved in vivo corrosion resistance, with 1/18 times the degradation rate of uncoated MgZnCa. These results not only comprehensively confirmed the validity of the VUV/O3-activation method as a coating strategy but also implied the tremendous potential of the modified Mg alloy for application as a degradable biomedical implant material. STATEMENT OF SIGNIFICANCE: MgZnCa alloy is a promising material in clinical implantation. Silk fibroin (SF) is a natural organic material with biocompatibility and biodegradability. To date, the combination of SF and MgZnCa alloy has exhibited considerable prospects for orthopedic applications. The realization of a direct coating is an enormous challenge because strong chemical bonds cannot be easily formed between organic and inorganic materials. To solve this bottleneck, we proposed a unique vacuum ultraviolet-ozone (VUV/O3) surface-activation method for the first time to modify the Mg alloy surface before SF coating, which significantly enhanced both in vitro and in vivo performance, such as superior biocompatibility and remarkably improved corrosion resistance of magnesium alloys (∼1/18 the in vivo degradation rate of uncoated MgZnCa).
Collapse
|
45
|
Bambauer TP, Maurer HH, Weber AA, Hannig M, Pütz N, Koch M, Manier SK, Schneider M, Meyer MR. Evaluation of novel organosilane modifications of paper spray mass spectrometry substrates for analyzing polar compounds. Talanta 2019; 204:677-684. [PMID: 31357352 DOI: 10.1016/j.talanta.2019.05.095] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2019] [Revised: 05/20/2019] [Accepted: 05/22/2019] [Indexed: 12/11/2022]
Abstract
Paper spray mass spectrometry (PSMS) is currently used in different analytical fields, but less effort has been made so far to use PSMS for highly polar compounds. Such analytes usually show poor performance in PSMS due to their high affinity for common paper substrates in addition to high matrix effects. In this study, strategies for hydrophobic modifications of commercially available paper substrates using ten different organosilanes were developed. The modified substrates were generated, characterized, and applied for PSMS analysis of polar toxins. By using the modified paper, PSMS performance of some of the toxins could be considerably increased, especially for orellanine, showing a more than 80-fold signal enhancement when substrates modified with chlorotrimethylsilane were used. For other toxins like ricinine, only small beneficial effects could be shown on PSMS performance when using modified substrates. Statistical equivalence tests showed sufficient ruggedness of the developed procedures also compared to conventional substrates. Thus, further systematic development of paper substrates modified with organosilane derivatives based on the presented study for application in PSMS should be encouraged.
Collapse
Affiliation(s)
- Thomas P Bambauer
- Department of Experimental and Clinical Toxicology, Institute of Experimental and Clinical Pharmacology and Toxicology, Saarland University, Center for Molecular Signaling (PZMS), 66421, Homburg, Germany
| | - Hans H Maurer
- Department of Experimental and Clinical Toxicology, Institute of Experimental and Clinical Pharmacology and Toxicology, Saarland University, Center for Molecular Signaling (PZMS), 66421, Homburg, Germany
| | - Armin A Weber
- Department of Experimental and Clinical Toxicology, Institute of Experimental and Clinical Pharmacology and Toxicology, Saarland University, Center for Molecular Signaling (PZMS), 66421, Homburg, Germany
| | - Matthias Hannig
- Clinic of Operative Dentistry, Periodontology and Preventive Dentistry, Saarland University Hospital, Homburg/Saar, Germany
| | - Norbert Pütz
- Department of Anatomy and Cell Biology, Saarland University, 66421 Homburg, Germany
| | - Marcus Koch
- INM-Leibniz Institute for New Materials, 66123, Saarbrücken, Germany
| | - Sascha K Manier
- Department of Experimental and Clinical Toxicology, Institute of Experimental and Clinical Pharmacology and Toxicology, Saarland University, Center for Molecular Signaling (PZMS), 66421, Homburg, Germany
| | - Marc Schneider
- Department of Pharmacy, Biopharmaceutics and Pharmaceutical Technology, Saarland University, 66123, Saarbruecken, Germany
| | - Markus R Meyer
- Department of Experimental and Clinical Toxicology, Institute of Experimental and Clinical Pharmacology and Toxicology, Saarland University, Center for Molecular Signaling (PZMS), 66421, Homburg, Germany.
| |
Collapse
|
46
|
Scalable Methods for Device Patterning as an Outstanding Challenge in Translating Paper-Based Microfluidics from the Academic Benchtop to the Point-of-Care. JOURNAL OF ANALYSIS AND TESTING 2019. [DOI: 10.1007/s41664-019-00093-0] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
|
47
|
Fast and Simple Fabrication of Superhydrophobic Coating by Polymer Induced Phase Separation. NANOMATERIALS 2019; 9:nano9030411. [PMID: 30862033 PMCID: PMC6473969 DOI: 10.3390/nano9030411] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/13/2019] [Revised: 03/04/2019] [Accepted: 03/05/2019] [Indexed: 02/07/2023]
Abstract
Polymerization-induced phase separation is comparatively applied to fabricating a superhydrophobic micro/nano surface by microwave and ultraviolet (UV) irradiation. The monolithic coatings can be tailored easily on different substrates with excellent chemical and mechanical stability in rigid conditions. Importantly, the patterned filter paper is successfully used for the colorimetric detection of nitrite handily.
Collapse
|
48
|
Abstract
We present a rapid (<10 s), cost-effective, unique single-step method for fabricating paper-based devices without necessitating any expensive instrumentation, simply by deploying correction pens that are otherwise commonly used for masking typos in printed or written matters. The marked regions formed by deposits from the correction pen demonstrate ubiquitous flow resistances to typical aqueous solutions and organic solvents in the transverse direction, resulting in a preferential bulk flow along the axial direction of the paper channels ‘fabricated’ in the process. Considering the simplicity and cost-effectiveness of this platform, it is deemed to be ideal for (bio) chemical sensing and point-of-care diagnostics in resource-limited settings.
Collapse
|
49
|
Wang J, Zhang L, Li X, Zhang X, Yu HZ. From kirigami to three-dimensional paper-based micro-analytical device: cut-and-paste fabrication and mobile app quantitation. RSC Adv 2019; 9:23267-23275. [PMID: 35514509 PMCID: PMC9067308 DOI: 10.1039/c9ra04014e] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2019] [Accepted: 07/10/2019] [Indexed: 11/28/2022] Open
Abstract
Nowadays quantitative chemical analysis is usually costly, instrument-dependent, and time-consuming, which limits its implementation for remote locations and resource-limited regions. Inspired by the ancient papercutting art (kirigami), we herein introduce a novel cut-and-paste protocol to fabricate 3D microfluidic paper-based analytical devices (μPADs) that are suitable for on-site quantitative assay applications. The preparation of the device is fast, simple, and independent of any lithographic devices or masks. Particularly designed reaction “channels” were pre-cut from a piece of filter paper, then assembled back to the silanized, superhydrophobic paper pads. The different layers of the device were assembled using a chemically-inert adhesive spray. The fabricated device has high efficiency of liquid handling (up to 60 times faster than conventional methods) and it is particularly inexpensive. Beyond the benchtop fabrication advantage, in conjunction with a custom mobile app developed for colorimetric analysis, we were able to quantify representative environmental contaminants (i.e., the amount of Cr(vi) and nitrite ions) in various water samples with the cut-and-paste μPADs (namely kPADs). Their detection limits (0.7 μg mL−1 for Cr(vi) and 0.4 μg mL−1 for nitrite ions, respectively) are comparable with conventional spectrophotometric methods, which confirm the potential of kPADs for on-site environmental/sanitary monitoring and food toxin pre-screening. The ancient papercutting art (kirigami) inspired a novel cut-and-paste protocol to fabricate paper-based micro-analytical devices for on-site quantitative assays.![]()
Collapse
Affiliation(s)
- Jianhua Wang
- College of Biomedical Engineering
- Taiyuan University of Technology
- Taiyuan
- China
| | - Lishen Zhang
- Department of Chemistry
- Simon Fraser University
- Burnaby
- Canada
| | - Xiaochun Li
- College of Biomedical Engineering
- Taiyuan University of Technology
- Taiyuan
- China
| | - Xiaoliang Zhang
- College of Biomedical Engineering
- Taiyuan University of Technology
- Taiyuan
- China
| | - Hua-Zhong Yu
- College of Biomedical Engineering
- Taiyuan University of Technology
- Taiyuan
- China
- Department of Chemistry
| |
Collapse
|
50
|
Wu F, Wang M. A Portable Smartphone-Based Sensing System Using a 3D-Printed Chip for On-Site Biochemical Assays. SENSORS 2018; 18:s18114002. [PMID: 30453578 PMCID: PMC6263889 DOI: 10.3390/s18114002] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/15/2018] [Revised: 11/08/2018] [Accepted: 11/13/2018] [Indexed: 12/14/2022]
Abstract
Recently, smartphone-based chromogenic sensing with paper-based microfluidic technology has played an increasingly important role in biochemical assays. However, generally there were three defects: (i) the paper-based chips still required complicated fabrication, and the hydrophobic boundaries on the chips were not clear enough; (ii) the chromogenic signals could not be steadily captured; (iii) the smartphone apps were restricted to the detection of specific target analytes and could not be extended for different assays unless reprogrammed. To solve these problems, in this study, a portable smartphone-based sensing system with a 3D-printed chip was developed. A 3D-printed imaging platform was designed to significantly reduce sensing errors generated during signal capture, and a brand-new strategy for signal processing in downloadable apps was established. As a proof-of-concept, the system was applied for detection of organophosphorus pesticides and multi-assay of fruit juice, showing excellent sensing performance. For different target analytes, the most efficient color channel could be selected for signal analysis, and the calibration equation could be directly set in user interface rather than programming environment, thus the developed system could be flexibly extended for other biochemical assays. Consequently, this study provides a novel methodology for smartphone-based biochemical sensing.
Collapse
Affiliation(s)
- Feiyi Wu
- Institute of Microanalytical Systems, Department of Chemistry, Zhejiang University, Hangzhou 310058, China.
| | - Min Wang
- Institute of Microanalytical Systems, Department of Chemistry, Zhejiang University, Hangzhou 310058, China.
| |
Collapse
|