Mostufa S, Rezaei B, Ciannella S, Yari P, Gómez-Pastora J, He R, Wu K. Advancements and Perspectives in Optical Biosensors. ACS OMEGA 2024; 9:24181-24202. [PMID: 38882113 PMCID: PMC11170745 DOI: 10.1021/acsomega.4c01872] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/26/2024] [Revised: 05/10/2024] [Accepted: 05/14/2024] [Indexed: 06/18/2024]
Abstract
Optical biosensors exhibit immense potential, offering extraordinary possibilities for biosensing due to their high sensitivity, reusability, and ultrafast sensing capabilities. This review provides a concise overview of optical biosensors, encompassing various platforms, operational mechanisms, and underlying physics, and it summarizes recent advancements in the field. Special attention is given to plasmonic biosensors and metasurface-based biosensors, emphasizing their significant performance in bioassays and, thus, their increasing attraction in biosensing research, positioning them as excellent candidates for lab-on-chip and point-of-care devices. For plasmonic biosensors, we emphasize surface plasmon resonance (SPR) and its subcategories, along with localized surface plasmon resonance (LSPR) devices and surface enhance Raman spectroscopy (SERS), highlighting their ability to perform diverse bioassays. Additionally, we discuss recently emerged metasurface-based biosensors. Toward the conclusion of this review, we address current challenges, opportunities, and prospects in optical biosensing. Considering the advancements and advantages presented by optical biosensors, it is foreseeable that they will become a robust and widespread platform for early disease diagnostics.
Collapse
Affiliation(s)
- Shahriar Mostufa
- Department of Electrical and Computer Engineering, Texas Tech University, Lubbock, Texas 79409, United States
| | - Bahareh Rezaei
- Department of Electrical and Computer Engineering, Texas Tech University, Lubbock, Texas 79409, United States
| | - Stefano Ciannella
- Department of Chemical Engineering, Texas Tech University, Lubbock, Texas 79409, United States
| | - Parsa Yari
- Department of Electrical and Computer Engineering, Texas Tech University, Lubbock, Texas 79409, United States
| | - Jenifer Gómez-Pastora
- Department of Chemical Engineering, Texas Tech University, Lubbock, Texas 79409, United States
| | - Rui He
- Department of Electrical and Computer Engineering, Texas Tech University, Lubbock, Texas 79409, United States
| | - Kai Wu
- Department of Electrical and Computer Engineering, Texas Tech University, Lubbock, Texas 79409, United States
| |
Collapse
|
2
|
Månsson A. The potential of myosin and actin in nanobiotechnology. J Cell Sci 2023; 136:292584. [PMID: 36861886 DOI: 10.1242/jcs.261025] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/03/2023] Open
Abstract
Since the late 1990s, efforts have been made to utilize cytoskeletal filaments, propelled by molecular motors, for nanobiotechnological applications, for example, in biosensing and parallel computation. This work has led to in-depth insights into the advantages and challenges of such motor-based systems, and has yielded small-scale, proof-of-principle applications but, to date, no commercially viable devices. Additionally, these studies have also elucidated fundamental motor and filament properties, as well as providing other insights obtained from biophysical assays in which molecular motors and other proteins are immobilized on artificial surfaces. In this Perspective, I discuss the progress towards practically viable applications achieved so far using the myosin II-actin motor-filament system. I also highlight several fundamental pieces of insights derived from the studies. Finally, I consider what may be required to achieve real devices in the future or at least to allow future studies with a satisfactory cost-benefit ratio.
Collapse
Affiliation(s)
- Alf Månsson
- Department of Chemistry and Biomedical Science, Linnaeus University, SE-391 82 Kalmar, Sweden
| |
Collapse
|
3
|
Asgari S, Wu G, Aghvami SA, Zhang Y, Lin M. Optimisation using the finite element method of a filter-based microfluidic SERS sensor for detection of multiple pesticides in strawberry. Food Addit Contam Part A Chem Anal Control Expo Risk Assess 2021; 38:646-658. [DOI: 10.1080/19440049.2021.1881624] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Affiliation(s)
- Sara Asgari
- Food Science Program, Division of Food System & Bioengineering, University of Missouri, Columbia, MO, USA
| | - Guangfu Wu
- Institute of Materials Science, University of Connecticut, Mansfield, CT, USA
| | | | - Yi Zhang
- Institute of Materials Science, University of Connecticut, Mansfield, CT, USA
| | - Mengshi Lin
- Food Science Program, Division of Food System & Bioengineering, University of Missouri, Columbia, MO, USA
| |
Collapse
|
4
|
Christodoulides N, McRae MP, Simmons GW, Modak SS, McDevitt JT. Sensors that Learn: The Evolution from Taste Fingerprints to Patterns of Early Disease Detection. MICROMACHINES 2019; 10:E251. [PMID: 30995728 PMCID: PMC6523560 DOI: 10.3390/mi10040251] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/29/2019] [Revised: 03/22/2019] [Accepted: 04/12/2019] [Indexed: 11/23/2022]
Abstract
The McDevitt group has sustained efforts to develop a programmable sensing platform that offers advanced, multiplexed/multiclass chem-/bio-detection capabilities. This scalable chip-based platform has been optimized to service real-world biological specimens and validated for analytical performance. Fashioned as a sensor that learns, the platform can host new content for the application at hand. Identification of biomarker-based fingerprints from complex mixtures has a direct linkage to e-nose and e-tongue research. Recently, we have moved to the point of big data acquisition alongside the linkage to machine learning and artificial intelligence. Here, exciting opportunities are afforded by multiparameter sensing that mimics the sense of taste, overcoming the limitations of salty, sweet, sour, bitter, and glutamate sensing and moving into fingerprints of health and wellness. This article summarizes developments related to the electronic taste chip system evolving into a platform that digitizes biology and affords clinical decision support tools. A dynamic body of literature and key review articles that have contributed to the shaping of these activities are also highlighted. This fully integrated sensor promises more rapid transition of biomarker panels into wide-spread clinical practice yielding valuable new insights into health diagnostics, benefiting early disease detection.
Collapse
Affiliation(s)
- Nicolaos Christodoulides
- Department of Biomaterials, College of Dentistry, Bioengineering Institute, New York University, New York, NY 10010, USA.
| | - Michael P McRae
- Department of Biomaterials, College of Dentistry, Bioengineering Institute, New York University, New York, NY 10010, USA.
| | - Glennon W Simmons
- Department of Biomaterials, College of Dentistry, Bioengineering Institute, New York University, New York, NY 10010, USA.
| | - Sayli S Modak
- Department of Biomaterials, College of Dentistry, Bioengineering Institute, New York University, New York, NY 10010, USA.
| | - John T McDevitt
- Department of Biomaterials, College of Dentistry, Bioengineering Institute, New York University, New York, NY 10010, USA.
| |
Collapse
|
5
|
Xu P, Zheng J, Zhou J, Chen Y, Zou C, Majumdar A. Multi-slot photonic crystal cavities for high-sensitivity refractive index sensing. OPTICS EXPRESS 2019; 27:3609-3616. [PMID: 30732377 PMCID: PMC6410913 DOI: 10.1364/oe.27.003609] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/27/2018] [Accepted: 01/24/2019] [Indexed: 05/26/2023]
Abstract
We present the design, fabrication, and characterization of a multi-slot photonic crystal (PhC) cavity sensor on the silicon-on-insulator platform. By optimizing the structure of the PhC cavity, most of the light can be distributed in the lower index region; thus, the sensitivity can be dramatically improved. By exposing the cavities to different mass concentrations of NaCl solutions, we obtained that the wavelength shift per refractive index unit (RIU) for the sensor is 586 nm/RIU, which is one of the highest sensitivities achieved in a non-suspended cavity. Furthermore, the size of the sensing region of the reported sensor is only 22.8 μm × 1.5 μm, making the high-sensitivity PhC cavity sensor attractive for the realization of on-chip sensor arrays.
Collapse
Affiliation(s)
- Peipeng Xu
- Laboratory of Infrared Materials and Devices, Advanced Technology Research Institute, Ningbo University, Ningbo 315211, China
- Key Laboratory of Photoelectric Detection Materials and Devices of Zhejiang Province, Ningbo, 315211, China
| | - Jiajiu Zheng
- Department of Electrical and Computer Engineering, University of Washington, Seattle, WA 98195, USA
| | - Jun Zhou
- Laboratory of Infrared Materials and Devices, Advanced Technology Research Institute, Ningbo University, Ningbo 315211, China
| | - Yueyang Chen
- Department of Electrical and Computer Engineering, University of Washington, Seattle, WA 98195, USA
| | - Chen Zou
- Department of Electrical and Computer Engineering, University of Washington, Seattle, WA 98195, USA
| | - Arka Majumdar
- Department of Electrical and Computer Engineering, University of Washington, Seattle, WA 98195, USA
- Department of Physics, University of Washington, Seattle, WA 98195, USA
| |
Collapse
|
6
|
Christodoulides NJ, McRae MP, Abram TJ, Simmons GW, McDevitt JT. Innovative Programmable Bio-Nano-Chip Digitizes Biology Using Sensors That Learn Bridging Biomarker Discovery and Clinical Implementation. Front Public Health 2017; 5:110. [PMID: 28589118 PMCID: PMC5441161 DOI: 10.3389/fpubh.2017.00110] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2016] [Accepted: 05/02/2017] [Indexed: 11/13/2022] Open
Abstract
The lack of standard tools and methodologies and the absence of a streamlined multimarker approval process have hindered the translation rate of new biomarkers into clinical practice for a variety of diseases afflicting humankind. Advanced novel technologies with superior analytical performance and reduced reagent costs, like the programmable bio-nano-chip system featured in this article, have potential to change the delivery of healthcare. This universal platform system has the capacity to digitize biology, resulting in a sensor modality with a capacity to learn. With well-planned device design, development, and distribution plans, there is an opportunity to translate benchtop discoveries in the genomics, proteomics, metabolomics, and glycomics fields by transforming the information content of key biomarkers into actionable signatures that can empower physicians and patients for a better management of healthcare. While the process is complicated and will take some time, showcased here are three application areas for this flexible platform that combines biomarker content with minimally invasive or non-invasive sampling, such as brush biopsy for oral cancer risk assessment; serum, plasma, and small volumes of blood for the assessment of cardiac risk and wellness; and oral fluid sampling for drugs of abuse testing at the point of need.
Collapse
Affiliation(s)
- Nicolaos J. Christodoulides
- Department of Biomaterials, Bioengineering Institute, New York University College of Dentistry, New York, NY, USA
| | - Michael P. McRae
- Department of Biomaterials, Bioengineering Institute, New York University College of Dentistry, New York, NY, USA
| | | | - Glennon W. Simmons
- Department of Biomaterials, Bioengineering Institute, New York University College of Dentistry, New York, NY, USA
| | - John T. McDevitt
- Department of Biomaterials, Bioengineering Institute, New York University College of Dentistry, New York, NY, USA
| |
Collapse
|
7
|
Li X, Gao X, Liu R, Wang J, Wu Z, Zhang L, Li H, Gui X, Kang B, Shi J. Optimization and validation of the protocol used to analyze the taste of traditional Chinese medicines using an electronic tongue. Exp Ther Med 2016; 12:2949-2957. [PMID: 27882100 PMCID: PMC5103729 DOI: 10.3892/etm.2016.3733] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2016] [Accepted: 07/21/2016] [Indexed: 01/15/2023] Open
Abstract
Tools to define the active ingredients and flavors of Traditional Chinese Medicines (TCMs) are limited by long analysis times, complex sample preparation and a lack of multiplexed analysis. The aim of the present study was to optimize and validate an electronic tongue (E-tongue) methodology to analyze the bitterness of TCMs. To test the protocol, 35 different TCM concoctions were measured using an E-tongue, and seven replicate measurements of each sample were taken to evaluate reproducibility and precision. E-tongue sensor information was identified and classified using analysis approaches including least squares support vector machine (LS-SVM), support vector machine (SVM), discriminant analysis (DA) and partial least squares (PLS). A benefit of this analytical protocol was that the analysis of a single sample took <15 min for all seven sensors. The results identified that the LS-SVM approach provided the best bitterness classification accuracy (binary classification accuracy, 100%; ternary classification accuracy, 89.66%). The E-tongue protocol developed showed good reproducibility and high precision within a 6 h measurement cycle. To the best of our knowledge, this is the first study of an E-tongue being applied to assay the bitterness of TCMs. This approach could be applied in the classification of the taste of TCMs, and serve important roles in other fields, including foods and beverages.
Collapse
Affiliation(s)
- Xuelin Li
- Department of Pharmacy, The First Affiliated Hospital of Henan University of Traditional Chinese Medicine, Zhengzhou, Henan 450000, P.R. China
| | - Xiaojie Gao
- School of Pharmacy, Henan University of Traditional Chinese Medicine, Zhengzhou, Henan 450008, P.R. China
| | - Ruixin Liu
- Department of Pharmacy, The First Affiliated Hospital of Henan University of Traditional Chinese Medicine, Zhengzhou, Henan 450000, P.R. China; The Level Three Laboratory of Chinese Traditional Medical Preparation of State Administration of TCM, Henan 450000, P.R. China; Key Laboratory of Viral Diseases Prevention and Treatment of TCM of Henan Province, Zhengzhou, Henan 450000, P.R. China
| | - Junming Wang
- School of Pharmacy, Henan University of Traditional Chinese Medicine, Zhengzhou, Henan 450008, P.R. China
| | - Zidan Wu
- School of Pharmacy, Henan University of Traditional Chinese Medicine, Zhengzhou, Henan 450008, P.R. China; Department of Computer Science and Statistics, University of Rhode Island, Kingston, RI 02881, USA
| | - Lu Zhang
- Department of Pharmacy, The First Affiliated Hospital of Henan University of Traditional Chinese Medicine, Zhengzhou, Henan 450000, P.R. China; The Level Three Laboratory of Chinese Traditional Medical Preparation of State Administration of TCM, Henan 450000, P.R. China; Key Laboratory of Viral Diseases Prevention and Treatment of TCM of Henan Province, Zhengzhou, Henan 450000, P.R. China
| | - Huiling Li
- School of Pharmacy, Henan University of Traditional Chinese Medicine, Zhengzhou, Henan 450008, P.R. China
| | - Xinjing Gui
- School of Pharmacy, Henan University of Traditional Chinese Medicine, Zhengzhou, Henan 450008, P.R. China
| | - Bingya Kang
- Department of Pharmacy, The First Affiliated Hospital of Henan University of Traditional Chinese Medicine, Zhengzhou, Henan 450000, P.R. China; The Level Three Laboratory of Chinese Traditional Medical Preparation of State Administration of TCM, Henan 450000, P.R. China; Key Laboratory of Viral Diseases Prevention and Treatment of TCM of Henan Province, Zhengzhou, Henan 450000, P.R. China
| | - Junhan Shi
- Department of Pharmacy, The First Affiliated Hospital of Henan University of Traditional Chinese Medicine, Zhengzhou, Henan 450000, P.R. China; The Level Three Laboratory of Chinese Traditional Medical Preparation of State Administration of TCM, Henan 450000, P.R. China; Key Laboratory of Viral Diseases Prevention and Treatment of TCM of Henan Province, Zhengzhou, Henan 450000, P.R. China
| |
Collapse
|
8
|
McRae MP, Simmons G, Wong J, McDevitt JT. Programmable Bio-nanochip Platform: A Point-of-Care Biosensor System with the Capacity To Learn. Acc Chem Res 2016; 49:1359-68. [PMID: 27380817 PMCID: PMC6504240 DOI: 10.1021/acs.accounts.6b00112] [Citation(s) in RCA: 40] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
The combination of point-of-care (POC) medical microdevices and machine learning has the potential transform the practice of medicine. In this area, scalable lab-on-a-chip (LOC) devices have many advantages over standard laboratory methods, including faster analysis, reduced cost, lower power consumption, and higher levels of integration and automation. Despite significant advances in LOC technologies over the years, several remaining obstacles are preventing clinical implementation and market penetration of these novel medical microdevices. Similarly, while machine learning has seen explosive growth in recent years and promises to shift the practice of medicine toward data-intensive and evidence-based decision making, its uptake has been hindered due to the lack of integration between clinical measurements and disease determinations. In this Account, we describe recent developments in the programmable bio-nanochip (p-BNC) system, a biosensor platform with the capacity for learning. The p-BNC is a "platform to digitize biology" in which small quantities of patient sample generate immunofluorescent signal on agarose bead sensors that is optically extracted and converted to antigen concentrations. The platform comprises disposable microfluidic cartridges, a portable analyzer, automated data analysis software, and intuitive mobile health interfaces. The single-use cartridges are fully integrated, self-contained microfluidic devices containing aqueous buffers conveniently embedded for POC use. A novel fluid delivery method was developed to provide accurate and repeatable flow rates via actuation of the cartridge's blister packs. A portable analyzer instrument was designed to integrate fluid delivery, optical detection, image analysis, and user interface, representing a universal system for acquiring, processing, and managing clinical data while overcoming many of the challenges facing the widespread clinical adoption of LOC technologies. We demonstrate the p-BNC's flexibility through the completion of multiplex assays within the single-use disposable cartridges for three clinical applications: prostate cancer, ovarian cancer, and acute myocardial infarction. Toward the goal of creating "sensors that learn", we have developed and describe here the Cardiac ScoreCard, a clinical decision support system for a spectrum of cardiovascular disease. The Cardiac ScoreCard approach comprises a comprehensive biomarker panel and risk factor information in a predictive model capable of assessing early risk and late-stage disease progression for heart attack and heart failure patients. These marker-driven tests have the potential to radically reduce costs, decrease wait times, and introduce new options for patients needing regular health monitoring. Further, these efforts demonstrate the clinical utility of fusing data from information-rich biomarkers and the Internet of Things (IoT) using predictive analytics to generate single-index assessments for wellness/illness status. By promoting disease prevention and personalized wellness management, tools of this nature have the potential to improve health care exponentially.
Collapse
Affiliation(s)
- Michael P. McRae
- Department of Bioengineering, Rice University, Houston, Texas 77030, United States
| | - Glennon Simmons
- Department of Biomaterials, Bioengineering Institute, New York University College of Dentistry, New York, New York 10010, United States
| | - Jorge Wong
- Department of Bioengineering, Rice University, Houston, Texas 77030, United States
- Department of Chemistry, Rice University, Houston, Texas 77030, United States
| | - John T. McDevitt
- Department of Bioengineering, Rice University, Houston, Texas 77030, United States
- Department of Biomaterials, Bioengineering Institute, New York University College of Dentistry, New York, New York 10010, United States
- Department of Chemistry, Rice University, Houston, Texas 77030, United States
| |
Collapse
|
9
|
McRae MP, Bozkurt B, Ballantyne CM, Sanchez X, Christodoulides N, Simmons G, Nambi V, Misra A, Miller CS, Ebersole JL, Campbell C, McDevitt JT. Cardiac ScoreCard: A Diagnostic Multivariate Index Assay System for Predicting a Spectrum of Cardiovascular Disease. EXPERT SYSTEMS WITH APPLICATIONS 2016; 54:136-147. [PMID: 31467464 PMCID: PMC6715313 DOI: 10.1016/j.eswa.2016.01.029] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/09/2023]
Abstract
Clinical decision support systems (CDSSs) have the potential to save lives and reduce unnecessary costs through early detection and frequent monitoring of both traditional risk factors and novel biomarkers for cardiovascular disease (CVD). However, the widespread adoption of CDSSs for the identification of heart diseases has been limited, likely due to the poor interpretability of clinically relevant results and the lack of seamless integration between measurements and disease predictions. In this paper we present the Cardiac ScoreCard-a multivariate index assay system with the potential to assist in the diagnosis and prognosis of a spectrum of CVD. The Cardiac ScoreCard system is based on lasso logistic regression techniques which utilize both patient demographics and novel biomarker data for the prediction of heart failure (HF) and cardiac wellness. Lasso logistic regression models were trained on a merged clinical dataset comprising 579 patients with 6 traditional risk factors and 14 biomarker measurements. The prediction performance of the Cardiac ScoreCard was assessed with 5-fold cross-validation and compared with reference methods. The experimental results reveal that the ScoreCard models improved performance in discriminating disease versus non-case (AUC = 0.8403 and 0.9412 for cardiac wellness and HF, respectively), and the models exhibit good calibration. Clinical insights to the prediction of HF and cardiac wellness are provided in the form of logistic regression coefficients which suggest that augmenting the traditional risk factors with a multimarker panel spanning a diverse cardiovascular pathophysiology provides improved performance over reference methods. Additionally, a framework is provided for seamless integration with biomarker measurements from point-of-care medical microdevices, and a lasso-based feature selection process is described for the down-selection of biomarkers in multimarker panels.
Collapse
Affiliation(s)
| | - Biykem Bozkurt
- Michael E. DeBakey VA Medical Center, Houston, TX, USA
- Section of Cardiology, Baylor College of Medicine, Houston, TX, USA
| | | | - Ximena Sanchez
- Department of Bioengineering, Rice University, Houston, TX, USA
- Department of Chemistry, Rice University, Houston, TX, USA
| | - Nicolaos Christodoulides
- Department of Bioengineering, Rice University, Houston, TX, USA
- Department of Chemistry, Rice University, Houston, TX, USA
| | - Glennon Simmons
- Department of Bioengineering, Rice University, Houston, TX, USA
- Department of Chemistry, Rice University, Houston, TX, USA
| | - Vijay Nambi
- Michael E. DeBakey VA Medical Center, Houston, TX, USA
- Section of Cardiology, Baylor College of Medicine, Houston, TX, USA
| | | | - Craig S. Miller
- Department of Oral Health Practice, Center for Oral Health Research, College of Dentistry University of Kentucky, Lexington, KY, USA
| | - Jeffrey L. Ebersole
- Department of Oral Health Practice, Center for Oral Health Research, College of Dentistry University of Kentucky, Lexington, KY, USA
| | - Charles Campbell
- Department of Cardiology, Erlanger Health System, Chattanooga, TN, USA
| | - John T. McDevitt
- Department of Bioengineering, Rice University, Houston, TX, USA
- Department of Chemistry, Rice University, Houston, TX, USA
| |
Collapse
|
10
|
McRae MP, Simmons G, McDevitt JT. Challenges and opportunities for translating medical microdevices: insights from the programmable bio-nano-chip. Bioanalysis 2016; 8:905-19. [PMID: 27071710 PMCID: PMC4870725 DOI: 10.4155/bio-2015-0023] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2015] [Accepted: 03/04/2016] [Indexed: 12/11/2022] Open
Abstract
This perspective highlights the major challenges for the bioanalytical community, in particular the area of lab-on-a-chip sensors, as they relate to point-of-care diagnostics. There is a strong need for general-purpose and universal biosensing platforms that can perform multiplexed and multiclass assays on real-world clinical samples. However, the adoption of novel lab-on-a-chip/microfluidic devices has been slow as several key challenges remain for the translation of these new devices to clinical practice. A pipeline of promising medical microdevice technologies will be made possible by addressing the challenges of integration, failure to compete with cost and performance of existing technologies, requisite for new content, and regulatory approval and clinical adoption.
Collapse
Affiliation(s)
- Michael P McRae
- Department of Bioengineering, Rice University, Houston, TX, USA
| | - Glennon Simmons
- Department of Biomaterials, New York University, New York, NY, USA
| | - John T McDevitt
- Department of Bioengineering, Rice University, Houston, TX, USA
- Department of Biomaterials, New York University, New York, NY, USA
- Department of Chemistry, Rice University, Houston, TX, USA
| |
Collapse
|
11
|
Last Advances in Silicon-Based Optical Biosensors. SENSORS 2016; 16:285. [PMID: 26927105 PMCID: PMC4813860 DOI: 10.3390/s16030285] [Citation(s) in RCA: 134] [Impact Index Per Article: 16.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/09/2015] [Revised: 01/25/2016] [Accepted: 02/18/2016] [Indexed: 12/11/2022]
Abstract
We review the most important achievements published in the last five years in the field of silicon-based optical biosensors. We focus specially on label-free optical biosensors and their implementation into lab-on-a-chip platforms, with an emphasis on developments demonstrating the capability of the devices for real bioanalytical applications. We report on novel transducers and materials, improvements of existing transducers, new and improved biofunctionalization procedures as well as the prospects for near future commercialization of these technologies.
Collapse
|
12
|
Liu G, Qi M, Hutchinson MR, Yang G, Goldys EM. Recent advances in cytokine detection by immunosensing. Biosens Bioelectron 2016; 79:810-21. [PMID: 26774995 DOI: 10.1016/j.bios.2016.01.020] [Citation(s) in RCA: 93] [Impact Index Per Article: 11.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2015] [Revised: 12/30/2015] [Accepted: 01/07/2016] [Indexed: 01/12/2023]
Abstract
The detection of cytokines in body fluids, cells, tissues and organisms continues to attract considerable attention due to the importance of these key cell signaling molecules in biology and medicine. In this review, we describe recent advances in cytokine detection in the course of ongoing pursuit of new analytical approaches for these trace analytes with specific focus on immunosensing. We discuss recent elegant designs of sensing interface with improved performance with respect to sensitivity, selectivity, stability, simplicity, and the absence of sample matrix effects. Various immunosensing approaches based on multifunctional nanomaterials open novel opportunities for ultrasensitive detection of cytokines in body fluids in vitro and in vivo. Methodologies such as suspension arrays also known as bead assays together with optical fiber-based sensors, on their own or in combination with microfluidic devices will continue to have an important role to address the grand challenge of real-time in vivo multiplex cytokine detection.
Collapse
Affiliation(s)
- Guozhen Liu
- Key Laboratory of Pesticide and Chemical Biology of Ministry of Education, College of Chemistry, Central China Normal University, Wuhan 430079, PR China; ARC Centre of Excellence in Nanoscale Biophotonics (CNBP), Macquarie University, North Ryde 2109, Australia
| | - Meng Qi
- Key Laboratory of Pesticide and Chemical Biology of Ministry of Education, College of Chemistry, Central China Normal University, Wuhan 430079, PR China
| | - Mark R Hutchinson
- ARC Centre of Excellence in Nanoscale Biophotonics (CNBP), The University of Adelaide, Adelaide 5005, Australia
| | - Guangfu Yang
- Key Laboratory of Pesticide and Chemical Biology of Ministry of Education, College of Chemistry, Central China Normal University, Wuhan 430079, PR China
| | - Ewa M Goldys
- ARC Centre of Excellence in Nanoscale Biophotonics (CNBP), Macquarie University, North Ryde 2109, Australia.
| |
Collapse
|
13
|
Kumar S, Milani G, Takatsuki H, Lana T, Persson M, Frasson C, te Kronnie G, Månsson A. Sensing protein antigen and microvesicle analytes using high-capacity biopolymer nano-carriers. Analyst 2015; 141:836-46. [PMID: 26617251 DOI: 10.1039/c5an02377g] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
Lab-on-a-chip systems with molecular motor driven transport of analytes attached to cytoskeletal filament shuttles (actin filaments, microtubules) circumvent challenges with nanoscale liquid transport. However, the filaments have limited cargo-carrying capacity and limitations either in transportation speed (microtubules) or control over motility direction (actin). To overcome these constraints we here report incorporation of covalently attached antibodies into self-propelled actin bundles (nanocarriers) formed by cross-linking antibody conjugated actin filaments via fascin, a natural actin-bundling protein. We demonstrate high maximum antigen binding activity and propulsion by surface adsorbed myosin motors. Analyte transport capacity is tested using both protein antigens and microvesicles, a novel class of diagnostic markers. Increased incubation concentration with protein antigen in the 0.1-100 nM range (1 min) reduces the fraction of motile bundles and their velocity but maximum transportation capacity of >1 antigen per nm of bundle length is feasible. At sub-nanomolar protein analyte concentration, motility is very well preserved opening for orders of magnitude improved limit of detection using motor driven concentration on nanoscale sensors. Microvesicle-complexing to monoclonal antibodies on the nanocarriers compromises motility but nanocarrier aggregation via microvesicles shows unique potential in label-free detection with the aggregates themselves as non-toxic reporter elements.
Collapse
Affiliation(s)
- Saroj Kumar
- Department of Chemistry and Biomedical Sciences, Linnaeus University, SE-391 82 Kalmar, Sweden.
| | | | | | | | | | | | | | | |
Collapse
|
14
|
McRae MP, Simmons GW, Wong J, Shadfan B, Gopalkrishnan S, Christodoulides N, McDevitt JT. Programmable bio-nano-chip system: a flexible point-of-care platform for bioscience and clinical measurements. LAB ON A CHIP 2015; 15:4020-31. [PMID: 26308851 PMCID: PMC4589532 DOI: 10.1039/c5lc00636h] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
Abstract
The development of integrated instrumentation for universal bioassay systems serves as a key goal for the lab-on-a-chip community. The programmable bio-nano-chip (p-BNC) system is a versatile multiplexed and multiclass chemical- and bio-sensing system for bioscience and clinical measurements. The system is comprised of two main components, a disposable cartridge and a portable analyzer. The customizable single-use plastic cartridges, which now can be manufactured in high volumes using injection molding, are designed for analytical performance, ease of use, reproducibility, and low cost. These labcard devices implement high surface area nano-structured biomarker capture elements that enable high performance signaling and are index-matched to real-world biological specimens. This detection modality, along with the convenience of on-chip fluid storage in blisters and self-contained waste, represents a standard process to digitize biological signatures at the point-of-care. A companion portable analyzer prototype has been developed to integrate fluid motivation, optical detection, and automated data analysis, and it serves as the human interface for complete assay automation. In this report, we provide a systems-level perspective of the p-BNC universal biosensing platform with an emphasis on flow control, device integration, and automation. To demonstrate the flexibility of the p-BNC, we distinguish diseased and non-case patients across three significant disease applications: prostate cancer, ovarian cancer, and acute myocardial infarction. Progress towards developing a rapid 7 minute myoglobin assay is presented using the fully automated p-BNC system.
Collapse
Affiliation(s)
| | - Glennon. W. Simmons
- Department of Bioengineering, Rice University, Houston, TX, U.S.A
- Department of Chemistry, Rice University, Houston, TX, U.S.A
| | - Jorge Wong
- Department of Bioengineering, Rice University, Houston, TX, U.S.A
- Department of Chemistry, Rice University, Houston, TX, U.S.A
| | - Basil Shadfan
- Department of Chemistry, Rice University, Houston, TX, U.S.A
| | | | - Nicolaos Christodoulides
- Department of Bioengineering, Rice University, Houston, TX, U.S.A
- Department of Chemistry, Rice University, Houston, TX, U.S.A
- Department of Biomaterials and Biomimetics, New York University College of Dentistry, New York, NY, U.S.A
| | - John T. McDevitt
- Department of Bioengineering, Rice University, Houston, TX, U.S.A
- Department of Chemistry, Rice University, Houston, TX, U.S.A
- Department of Biomaterials and Biomimetics, New York University College of Dentistry, New York, NY, U.S.A
| |
Collapse
|
15
|
McDevitt JT, McRae MP, Simmons GW, Christodoulides N. Programmable bio-nano-chip system: a flexible diagnostic platform that learns. JOURNAL OF BIOSENSORS & BIOELECTRONICS 2015; 6:e137. [PMID: 30918744 PMCID: PMC6432931 DOI: 10.4172/2155-6210.1000e137] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Affiliation(s)
- John T McDevitt
- Department of Biomaterials, New York University College of Dentistry, New York, NY, USA
- Department of Bioengineering, Rice University, Houston, TX, USA
- Department of Chemistry, Rice University, Houston, TX, USA
| | - Michael P McRae
- Department of Bioengineering, Rice University, Houston, TX, USA
| | - Glennon W Simmons
- Department of Biomaterials, New York University College of Dentistry, New York, NY, USA
- Department of Bioengineering, Rice University, Houston, TX, USA
- Department of Chemistry, Rice University, Houston, TX, USA
| | - Nicolaos Christodoulides
- Department of Bioengineering, Rice University, Houston, TX, USA
- Department of Chemistry, Rice University, Houston, TX, USA
| |
Collapse
|
16
|
Leary TF, Manafirasi S, Maldarelli C. Mass transfer in the biomolecular binding of a target against probe molecules on the surface of microbeads sequestered in wells in a microfluidic cell. LAB ON A CHIP 2015; 15:459-77. [PMID: 25408192 DOI: 10.1039/c4lc01185f] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/08/2023]
Abstract
Diagnostic tools which screen the binding interactions of a protein target against a display of biomolecular probes to identify molecules which bind the target are central to cell proteomic studies, and to diagnostic assays. Here, we study a microfluidic design for screening interactions in which the probe molecules are hosted on microbeads sequestered in wells arranged at the bottom of a microfluidic flow channel. Assays are undertaken by streaming an analyte solution with a fluorescently labelled target through the cell, and identifying the fluorescing beads. Numerical simulations are first constructed for the analyte flow over the microbeads in the well array, and the increase in the target concentration on the microbead surface. The binding profile is expressed as a function of the ratio of the convective to the diffusive transport rates (Peclet number or Pe), and the ratio of the kinetic to the diffusive rates (Damkohler number, Da). For any Pe, as Da becomes small enough, the transport is determined by the intrinsic kinetic binding rate. As Pe increases, a thin concentration boundary layer develops over the top surface of the microbead because of the convective flow, and target binds more rapidly. However, the relatively stagnant layers of liquid in the well provide a diffusion barrier which slows the target transport, and for any Da and Pe the transport is slower than equivalent patches of probes arranged on the channel wall. Experiments are also undertaken at high Pe, using the binding of fluorescently labelled NeutrAvidin as a target to probes of its binding partner, biotin, on the microbead surface. The binding profile is compared to the simulations to measure the kinetic rate constant, and this comparison shows that the transport in the cell is not kinetically limited because of the diffusion barriers created by the stagnant liquid layer in the well. Simulations and experiments on microbeads which are only partially recessed in the well demonstrate an increase in the mass transfer rate as more of the microbead surface intersects the flow and the diffusion limitation due to the stagnant layer of liquid surrounding the bottom part of the microbead is minimized.
Collapse
Affiliation(s)
- Thomas F Leary
- Levich Institute and Department of Chemical Engineering, The City College of the City University of New York, New York, New York 10031, USA.
| | | | | |
Collapse
|
17
|
Saha A, Jana NR. Paper-based microfluidic approach for surface-enhanced raman spectroscopy and highly reproducible detection of proteins beyond picomolar concentration. ACS APPLIED MATERIALS & INTERFACES 2015; 7:996-1003. [PMID: 25521159 DOI: 10.1021/am508123x] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/07/2023]
Abstract
Although microfluidic approach is widely used in various point of care diagnostics, its implementation in surface enhanced Raman spectroscopy (SERS)-based detection is challenging. This is because SERS signal depends on plasmonic nanoparticle aggregation induced generation of stable electromagnetic hot spots and in currently available microfluidic platform this condition is difficult to adapt. Here we show that SERS can be adapted using simple paper based microfluidic system where both the plasmonic nanomaterials and analyte are used in mobile phase. This approach allows analyte induced controlled particle aggregation and electromagnetic hot spot generation inside the microfluidic channel with the resultant SERS signal, which is highly reproducible and sensitive. This approach has been used for reproducible detection of protein in the pico to femtomolar concentration. Presented approach is simple, rapid, and cost-effective, and requires low sample volume. Method can be extended for SERS-based detection of other biomolecules.
Collapse
Affiliation(s)
- Arindam Saha
- Centre for Advanced Materials, Indian Association for the Cultivation of Science , Kolkata 700032, India
| | | |
Collapse
|
18
|
Stenken JA, Poschenrieder AJ. Bioanalytical chemistry of cytokines--a review. Anal Chim Acta 2015; 853:95-115. [PMID: 25467452 PMCID: PMC4717841 DOI: 10.1016/j.aca.2014.10.009] [Citation(s) in RCA: 192] [Impact Index Per Article: 21.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2014] [Revised: 09/30/2014] [Accepted: 10/08/2014] [Indexed: 02/06/2023]
Abstract
Cytokines are bioactive proteins produced by many different cells of the immune system. Due to their role in different inflammatory disease states and maintaining homeostasis, there is enormous clinical interest in the quantitation of cytokines. The typical standard methods for quantitation of cytokines are immunoassay-based techniques including enzyme-linked immusorbent assays (ELISA) and bead-based immunoassays read by either standard or modified flow cytometers. A review of recent developments in analytical methods for measurements of cytokine proteins is provided. This review briefly covers cytokine biology and the analysis challenges associated with measurement of these biomarker proteins for understanding both health and disease. New techniques applied to immunoassay-based assays are presented along with the uses of aptamers, electrochemistry, mass spectrometry, optical resonator-based methods. Methods used for elucidating the release of cytokines from single cells as well as in vivo collection methods are described.
Collapse
Affiliation(s)
- Julie A Stenken
- Department of Chemistry and Biochemistry, University of Arkansas, Fayetteville, AR 72701, USA.
| | - Andreas J Poschenrieder
- Department of Chemistry and Biochemistry, University of Arkansas, Fayetteville, AR 72701, USA; Pharmaceutical Radiochemistry, Technische Universität München, Walther-Meißner-Street 3, D-85748 Garching, Germany
| |
Collapse
|
19
|
Shadfan BH, Simmons AR, Simmons GW, Ho A, Wong J, Lu KH, Bast RC, McDevitt JT. A multiplexable, microfluidic platform for the rapid quantitation of a biomarker panel for early ovarian cancer detection at the point-of-care. Cancer Prev Res (Phila) 2014; 8:37-48. [PMID: 25388014 DOI: 10.1158/1940-6207.capr-14-0248] [Citation(s) in RCA: 52] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Point-of-care (POC) diagnostic platforms have the potential to enable low-cost, large-scale screening. As no single biomarker is shed by all ovarian cancers, multiplexed biomarker panels promise improved sensitivity and specificity to address the unmet need for early detection of ovarian cancer. We have configured the programmable bio-nano-chip (p-BNC)-a multiplexable, microfluidic, modular platform-to quantify a novel multi-marker panel comprising CA125, HE4, MMP-7, and CA72-4. The p-BNC is a bead-based immunoanalyzer system with a credit-card-sized footprint that integrates automated sample metering, bubble and debris removal, reagent storage and waste disposal, permitting POC analysis. Multiplexed p-BNC immunoassays demonstrated high specificity, low cross-reactivity, low limits of detection suitable for early detection, and a short analysis time of 43 minutes. Day-to-day variability, a critical factor for longitudinally monitoring biomarkers, ranged between 5.4% and 10.5%, well below the biologic variation for all four markers. Biomarker concentrations for 31 late-stage sera correlated well (R(2) = 0.71 to 0.93 for various biomarkers) with values obtained on the Luminex platform. In a 31 patient cohort encompassing early- and late-stage ovarian cancers along with benign and healthy controls, the multiplexed p-BNC panel was able to distinguish cases from controls with 68.7% sensitivity at 80% specificity. Utility for longitudinal biomarker monitoring was demonstrated with prediagnostic plasma from 2 cases and 4 controls. Taken together, the p-BNC shows strong promise as a diagnostic tool for large-scale screening that takes advantage of faster results and lower costs while leveraging possible improvement in sensitivity and specificity from biomarker panels.
Collapse
Affiliation(s)
| | - Archana R Simmons
- Department of Chemistry, Rice University, Houston, Texas. Department of Bioengineering, Rice University, Houston, Texas
| | - Glennon W Simmons
- Department of Chemistry, Rice University, Houston, Texas. Department of Bioengineering, Rice University, Houston, Texas
| | - Andy Ho
- Department of Chemistry, Rice University, Houston, Texas. Department of Bioengineering, Rice University, Houston, Texas
| | - Jorge Wong
- Department of Chemistry, Rice University, Houston, Texas. Department of Bioengineering, Rice University, Houston, Texas
| | - Karen H Lu
- Department of Gynecologic Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas
| | - Robert C Bast
- Department of Experimental Therapeutics, The University of Texas MD Anderson Cancer Center, Houston, Texas
| | - John T McDevitt
- Department of Chemistry, Rice University, Houston, Texas. Department of Bioengineering, Rice University, Houston, Texas.
| |
Collapse
|
20
|
Watkins NN, Hassan U, Damhorst G, Ni H, Vaid A, Rodriguez W, Bashir R. Microfluidic CD4+ and CD8+ T lymphocyte counters for point-of-care HIV diagnostics using whole blood. Sci Transl Med 2014; 5:214ra170. [PMID: 24307694 DOI: 10.1126/scitranslmed.3006870] [Citation(s) in RCA: 93] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Roughly 33 million people worldwide are infected with HIV; disease burden is highest in resource-limited settings. One important diagnostic in HIV disease management is the absolute count of lymphocytes expressing the CD4(+) and CD8(+) receptors. The current diagnostic instruments and procedures require expensive equipment and trained technicians. In response, we have developed microfluidic biochips that count CD4(+) and CD8(+) lymphocytes in whole blood samples, without the need for off-chip sample preparation. The device is based on differential electrical counting and relies on five on-chip modules that, in sequence, chemically lyses erythrocytes, quenches lysis to preserve leukocytes, enumerates cells electrically, depletes the target cells (CD4 or CD8) with antibodies, and enumerates the remaining cells electrically. We demonstrate application of this chip using blood from healthy and HIV-infected subjects. Erythrocyte lysis and quenching durations were optimized to create pure leukocyte populations in less than 1 min. Target cell depletion was accomplished through shear stress-based immunocapture, using antibody-coated microposts to increase the contact surface area and enhance depletion efficiency. With the differential electrical counting method, device-based CD4(+) and CD8(+) T cell counts closely matched control counts obtained from flow cytometry, over a dynamic range of 40 to 1000 cells/μl. By providing accurate cell counts in less than 20 min, from samples obtained from one drop of whole blood, this approach has the potential to be realized as a handheld, battery-powered instrument that would deliver simple HIV diagnostics to patients anywhere in the world, regardless of geography or socioeconomic status.
Collapse
Affiliation(s)
- Nicholas N Watkins
- Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, William L. Everett Laboratory, 1406 West Green Street, Urbana, IL 61801, USA
| | | | | | | | | | | | | |
Collapse
|
21
|
Lard M, ten Siethoff L, Generosi J, Månsson A, Linke H. Molecular motor transport through hollow nanowires. NANO LETTERS 2014; 14:3041-3046. [PMID: 24874101 DOI: 10.1021/nl404714b] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
Biomolecular motors offer self-propelled, directed transport in designed microscale networks and can potentially replace pump-driven nanofluidics. However, in existing systems, transportation is limited to the two-dimensional plane. Here we demonstrate fully one-dimensional (1D) myosin-driven motion of fluorescent probes (actin filaments) through 80 nm wide, Al2O3 hollow nanowires of micrometer length. The motor-driven transport is orders of magnitude faster than would be possible by passive diffusion. The system represents a necessary element for advanced devices based on gliding assays, for example, in lab-on-a-chip systems with channel crossings and in pumpless nanosyringes. It may also serve as a scaffold for bottom-up assembly of muscle proteins into ordered contractile units, mimicking the muscle sarcomere.
Collapse
Affiliation(s)
- Mercy Lard
- Nanometer Structure Consortium (nmC@LU) and Solid State Physics, Lund University , Box 118, SE-221 00 Lund, Sweden
| | | | | | | | | |
Collapse
|
22
|
Eicher D, Merten CA. Microfluidic devices for diagnostic applications. Expert Rev Mol Diagn 2014; 11:505-19. [DOI: 10.1586/erm.11.25] [Citation(s) in RCA: 45] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
|
23
|
Ritzi-Lehnert M. Development of chip-compatible sample preparation for diagnosis of infectious diseases. Expert Rev Mol Diagn 2014; 12:189-206. [DOI: 10.1586/erm.11.98] [Citation(s) in RCA: 41] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
|
24
|
Damhorst GL, Watkins NN, Bashir R. Micro- and nanotechnology for HIV/AIDS diagnostics in resource-limited settings. IEEE Trans Biomed Eng 2013; 60:715-26. [PMID: 23512111 DOI: 10.1109/tbme.2013.2244894] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Thirty-four million people are living with HIV worldwide, a disproportionate number of whom live in resource-limited settings. Proper clinical management of AIDS, the disease caused by HIV, requires regular monitoring of both the status of the host's immune system and levels of the virus in their blood. Therefore, more accessible technologies capable of performing a CD4+ T cell count and HIV viral load measurement in settings where HIV is most prevalent are desperately needed to enable better treatment strategies and ultimately quell the spread of the virus within populations. This review discusses micro- and nanotechnology solutions to performing these key clinical measurements in resource-limited settings.
Collapse
Affiliation(s)
- Gregory L Damhorst
- Department of Bioengineering and the Micro and Nanotechnology Laboratory, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA.
| | | | | |
Collapse
|
25
|
Amin AM, Thakur R, Madren S, Chuang HS, Thottethodi M, Vijaykumar TN, Wereley ST, Jacobson SC. Software-programmable continuous-flow multi-purpose lab-on-a-chip. MICROFLUIDICS AND NANOFLUIDICS 2013; 15:647-659. [PMID: 24436691 PMCID: PMC3889662 DOI: 10.1007/s10404-013-1180-2] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/07/2023]
Abstract
Current lab-on-a-chip (LoC) devices are assay-specific and are custom-built for each single experiment. Performing an experiment requires scientists or engineers to go through the time-consuming process of designing, fabricating, and testing a chip before conducting the actual experiment. This prolonged cycle can take months to complete, increasing effort and cost and reducing productivity. Similarly, minor modifications to an assay protocol re-incur the overheads of the design cycle. In this paper, we develop a multi-purpose, software-programmableLab-on-a-Chip (SPLoC), where the user simply writes or downloads a program for each experiment. We describe the components necessary to realize the SPLoC, which include a high-level programming language, an abstract instruction set, a runtime and control system, and a microfluidic device. We describe two key features of our high-level language compiler, and describe a novel variable-volume variable-ratio mixer. Finally, we demonstrate our SPLoC on four diverse, real-world assays.
Collapse
Affiliation(s)
- Ahmed M Amin
- Microfluidic Innovations, West Lafayette, IN 47906, USA
| | - Raviraj Thakur
- Birck Nanotechnology Center, School of Mechanical Engineering, Purdue University, West Lafayette, IN 47907, USA
| | - Seth Madren
- Department of Chemistry, Indiana University, Bloomington, IN 47405, USA
| | - Han-Sheng Chuang
- Department of Biomedical Engineering, National Cheng Kung University, Tainan, Taiwan
| | - Mithuna Thottethodi
- School of Electrical and Computer N.Engineering, Purdue University, West Lafayette, IN 47907, USA
| | - T N Vijaykumar
- School of Electrical and Computer N.Engineering, Purdue University, West Lafayette, IN 47907, USA
| | - Steven T Wereley
- Birck Nanotechnology Center, School of Mechanical Engineering, Purdue University, West Lafayette, IN 47907, USA
| | | |
Collapse
|
26
|
Chen X, Shojaei-Zadeh S, Gilchrist ML, Maldarelli C. A lipobead microarray assembled by particle entrapment in a microfluidic obstacle course and used for the display of cell membrane receptors. LAB ON A CHIP 2013; 13:3041-3060. [PMID: 23748734 DOI: 10.1039/c3lc50083g] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
Platforms which can display cell membrane ligands and receptors as a microarray library of probes for screening against a target are essential tools in drug discovery, biomarker identification, and pathogen detection. Membrane receptors and ligands require their native bilayer environment to retain their selectivity and binding affinity, and this complicates displaying them in a microarray platform. In this study, a design is developed in which the probes are first incorporated in supported lipid bilayers formed around micron-sized particles (lipobeads), and the microbeads themselves are then arrayed on a surface by hydrodynamic capture in a microfluidic obstacle course of traps. The traps are "V" shaped open enclosures, which are arranged in a wide channel of a microfluidic device, and capture the lipobeads (slightly smaller than the channel height) as they are streamed through the course. Screening assays are undertaken directly in the device after assembly, by streaming a fluorescently labeled target through the device and detecting the bead fluorescence. Conditions are first established for which the supported bilayers on the bead surface remain intact during the capture and assay steps, using fluorescent tags in the bilayer to infer bilayer integrity. Numerical calculations of the hydrodynamic drag coefficient on the entrapped beads are presented in conjunction with the stability experiments to develop criteria for the bilayer stability as a function of the screening assay perfusion rate. Simulations of the flow streamlines are also presented to quantify the trapping efficiency of the obstacle course. Screening assays are illustrated, assaying fluorescently labeled NeutrAvidin with biotin, and labeled cholera toxin with its ganglioside binding ligand, GM1. Sequential capturing of sets of lipobeads (one at a time, and with each set bearing a different probe), followed by indexing the bead positions after each set is entrapped, allows for the construction of an indexed array of multiple probes without the need for particle encoding and is illustrated using the NeutrAvidin-biotin pair. Finally, the lipobead platform is used for quantitatively measuring the kinetic rate constants for the binding of a probe (biotin) to a target (NeutrAvidin).
Collapse
Affiliation(s)
- Xiaoxiao Chen
- Levich Institute and Department of Chemical Engineering, The City College of the City University of New York, New York, New York 10031, USA
| | | | | | | |
Collapse
|
27
|
Novak MT, Kotanen CN, Carrara S, Guiseppi-Elie A, Moussy FG. Diagnostic tools and technologies for infectious and non-communicable diseases in low-and-middle-income countries. HEALTH AND TECHNOLOGY 2013. [DOI: 10.1007/s12553-013-0060-9] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
28
|
Magnetic capture from blood rescues molecular motor function in diagnostic nanodevices. J Nanobiotechnology 2013; 11:14. [PMID: 23638952 PMCID: PMC3660291 DOI: 10.1186/1477-3155-11-14] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2013] [Accepted: 04/29/2013] [Indexed: 01/29/2023] Open
Abstract
BACKGROUND Introduction of effective point-of-care devices for use in medical diagnostics is part of strategies to combat accelerating health-care costs. Molecular motor driven nanodevices have unique potentials in this regard due to unprecedented level of miniaturization and independence of external pumps. However motor function has been found to be inhibited by body fluids. RESULTS We report here that a unique procedure, combining separation steps that rely on antibody-antigen interactions, magnetic forces applied to magnetic nanoparticles (MPs) and the specificity of the actomyosin bond, can circumvent the deleterious effects of body fluids (e.g. blood serum). The procedure encompasses the following steps: (i) capture of analyte molecules from serum by MP-antibody conjugates, (ii) pelleting of MP-antibody-analyte complexes, using a magnetic field, followed by exchange of serum for optimized biological buffer, (iii) mixing of MP-antibody-analyte complexes with actin filaments conjugated with same polyclonal antibodies as the magnetic nanoparticles. This causes complex formation: MP-antibody-analyte-antibody-actin, and magnetic separation is used to enrich the complexes. Finally (iv) the complexes are introduced into a nanodevice for specific binding via actin filaments to surface adsorbed molecular motors (heavy meromyosin). The number of actin filaments bound to the motors in the latter step was significantly increased above the control value if protein analyte (50-60 nM) was present in serum (in step i) suggesting appreciable formation and enrichment of the MP-antibody-analyte-antibody-actin complexes. Furthermore, addition of ATP demonstrated maintained heavy meromyosin driven propulsion of actin filaments showing that the serum induced inhibition was alleviated. Detailed analysis of the procedure i-iv, using fluorescence microscopy and spectroscopy identified main targets for future optimization. CONCLUSION The results demonstrate a promising approach for capturing analytes from serum for subsequent motor driven separation/detection. Indeed, the observed increase in actin filament number, in itself, signals the presence of analyte at clinically relevant nM concentration without the need for further motor driven concentration. Our analysis suggests that exchange of polyclonal for monoclonal antibodies would be a critical improvement, opening for a first clinically useful molecular motor driven lab-on-a-chip device.
Collapse
|
29
|
Lard M, Ten Siethoff L, Kumar S, Persson M, Te Kronnie G, Linke H, Månsson A. Ultrafast molecular motor driven nanoseparation and biosensing. Biosens Bioelectron 2013; 48:145-52. [PMID: 23672875 DOI: 10.1016/j.bios.2013.03.071] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2013] [Revised: 03/27/2013] [Accepted: 03/28/2013] [Indexed: 11/29/2022]
Abstract
Portable biosensor systems would benefit from reduced dependency on external power supplies as well as from further miniaturization and increased detection rate. Systems built around self-propelled biological molecular motors and cytoskeletal filaments hold significant promise in these regards as they are built from nanoscale components that enable nanoseparation independent of fluidic pumping. Previously reported microtubule-kinesin based devices are slow, however, compared to several existing biosensor systems. Here we demonstrate that this speed limitation can be overcome by using the faster actomyosin motor system. Moreover, due to lower flexural rigidity of the actin filaments, smaller features can be achieved compared to microtubule-based systems, enabling further miniaturization. Using a device designed through optimization by Monte Carlo simulations, we demonstrate extensive myosin driven enrichment of actin filaments on a detector area of less than 10 μm², with a concentration half-time of approximately 40 s. We also show accumulation of model analyte (streptavidin at nanomolar concentration in nanoliter effective volume) detecting increased fluorescence intensity within seconds after initiation of motor-driven transportation from capture regions. We discuss further optimizations of the system and incorporation into a complete biosensing workflow.
Collapse
Affiliation(s)
- Mercy Lard
- The Nanometer Structure Consortium (nmC@LU), Division of Solid State Physics, Lund University, SE-22100 Lund, Sweden
| | | | | | | | | | | | | |
Collapse
|
30
|
Christodoulides N, Pierre FN, Sanchez X, Li L, Hocquard K, Patton A, Muldoon R, Miller CS, Ebersole JL, Redding S, Yeh CK, Furmaga WB, Wampler DA, Bozkurt B, Ballantyne CM, McDevitt JT. Programmable bio-nanochip technology for the diagnosis of cardiovascular disease at the point-of-care. Methodist Debakey Cardiovasc J 2012; 8:6-12. [PMID: 22891104 DOI: 10.14797/mdcj-8-1-6] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023] Open
Abstract
Cardiovascular disease remains the leading cause of death in the world and continues to serve as the major contributor to healthcare costs. Likewise, there is an ever-increasing need and demand for novel and more efficient diagnostic tools for the early detection of cardiovascular disease, especially at the point-of-care (POC). This article reviews the programmable bio-nanochip (P-BNC) system, a new medical microdevice approach with the capacity to deliver both high performance and reduced cost. This fully integrated, total analysis system leverages microelectronic components, microfabrication techniques, and nanotechnology to noninvasively measure multiple cardiac biomarkers in complex fluids, such as saliva, while offering diagnostic accuracy equal to laboratory-confined reference methods. This article profiles the P-BNC approach, describes its performance in real-world testing of clinical samples, and summarizes new opportunities for medical microdevices in the field of cardiac diagnostics.
Collapse
|
31
|
Chou J, Li LE, Kulla E, Christodoulides N, Floriano PN, McDevitt JT. Effects of sample delivery on analyte capture in porous bead sensors. LAB ON A CHIP 2012; 12:5249-56. [PMID: 23117481 PMCID: PMC3541674 DOI: 10.1039/c2lc40752c] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/07/2023]
Abstract
Sample delivery is a crucial aspect of point-of-care applications where sample volumes need to be low and assay times short, while providing high analytical and clinical sensitivity. In this paper, we explore the influence of the factors surrounding sample delivery on analyte capture in an immunoassay-based sensor array manifold of porous beads resting in individual wells. We model using computational fluid dynamics and a flow-through device containing beads sensitized specifically to C-reactive protein (CRP) to explore the effects of volume of sample, rate of sample delivery, and use of recirculation vs. unilateral delivery on the effectiveness of the capture of CRP on and within the porous bead sensor. Rate of sample delivery lends to the development of a time-dependent, shrinking depletion region around the bead exterior. Our findings reveal that at significantly high rates of delivery, unique to porous bead substrates, capture at the rim of the bead is reaction-limited, while capture in the interior of the bead is transport-limited. While the fluorescence signal results from the aggregate of captured material throughout the bead, multiple kinetic regimes exist within the bead. Further, under constant pressure conditions dictated by the array architecture, we reveal the existence of an optimal flow rate that generates the highest signal, under point-of-care constraints of limited-volume and limited-time. When high sensitivity is needed, recirculation can be implemented to overcome the analyte capture limitations due to volume and time constraints. Computational simulations agree with experimental results performed under similar conditions.
Collapse
Affiliation(s)
- Jie Chou
- Department of Bioengineering, Rice University, Houston, Texas77005, USA
| | | | | | | | | | | |
Collapse
|
32
|
Chou J, Wong J, Christodoulides N, Floriano PN, Sanchez X, McDevitt J. Porous bead-based diagnostic platforms: bridging the gaps in healthcare. SENSORS (BASEL, SWITZERLAND) 2012; 12:15467-99. [PMID: 23202219 PMCID: PMC3522972 DOI: 10.3390/s121115467] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/01/2012] [Revised: 10/25/2012] [Accepted: 11/01/2012] [Indexed: 01/11/2023]
Abstract
Advances in lab-on-a-chip systems have strong potential for multiplexed detection of a wide range of analytes with reduced sample and reagent volume; lower costs and shorter analysis times. The completion of high-fidelity multiplexed and multiclass assays remains a challenge for the medical microdevice field; as it struggles to achieve and expand upon at the point-of-care the quality of results that are achieved now routinely in remote laboratory settings. This review article serves to explore for the first time the key intersection of multiplexed bead-based detection systems with integrated microfluidic structures alongside porous capture elements together with biomarker validation studies. These strategically important elements are evaluated here in the context of platform generation as suitable for near-patient testing. Essential issues related to the scalability of these modular sensor ensembles are explored as are attempts to move such multiplexed and multiclass platforms into large-scale clinical trials. Recent efforts in these bead sensors have shown advantages over planar microarrays in terms of their capacity to generate multiplexed test results with shorter analysis times. Through high surface-to-volume ratios and encoding capabilities; porous bead-based ensembles; when combined with microfluidic elements; allow for high-throughput testing for enzymatic assays; general chemistries; protein; antibody and oligonucleotide applications.
Collapse
Affiliation(s)
- Jie Chou
- Department of Bioengineering, Rice University, 6100 Main St MS-142, Houston, TX 77005, USA; E-Mails: (J.C.); (N.C.); (P.N.F.); (X.S.)
| | - Jorge Wong
- Department of Chemistry, University of Texas at Austin, 1 University Station A5300, Austin, TX 78712, USA; E-Mail:
| | - Nicolaos Christodoulides
- Department of Bioengineering, Rice University, 6100 Main St MS-142, Houston, TX 77005, USA; E-Mails: (J.C.); (N.C.); (P.N.F.); (X.S.)
- Department of Chemistry, Rice University, 6100 Main St MS-142, Houston, TX 77005, USA
| | - Pierre N. Floriano
- Department of Bioengineering, Rice University, 6100 Main St MS-142, Houston, TX 77005, USA; E-Mails: (J.C.); (N.C.); (P.N.F.); (X.S.)
- Department of Chemistry, Rice University, 6100 Main St MS-142, Houston, TX 77005, USA
| | - Ximena Sanchez
- Department of Bioengineering, Rice University, 6100 Main St MS-142, Houston, TX 77005, USA; E-Mails: (J.C.); (N.C.); (P.N.F.); (X.S.)
- Department of Chemistry, Rice University, 6100 Main St MS-142, Houston, TX 77005, USA
| | - John McDevitt
- Department of Bioengineering, Rice University, 6100 Main St MS-142, Houston, TX 77005, USA; E-Mails: (J.C.); (N.C.); (P.N.F.); (X.S.)
- Department of Chemistry, Rice University, 6100 Main St MS-142, Houston, TX 77005, USA
| |
Collapse
|
33
|
Kumar S, ten Siethoff L, Persson M, Lard M, te Kronnie G, Linke H, Månsson A. Antibodies covalently immobilized on actin filaments for fast myosin driven analyte transport. PLoS One 2012; 7:e46298. [PMID: 23056279 PMCID: PMC3463588 DOI: 10.1371/journal.pone.0046298] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2012] [Accepted: 08/29/2012] [Indexed: 01/09/2023] Open
Abstract
Biosensors would benefit from further miniaturization, increased detection rate and independence from external pumps and other bulky equipment. Whereas transportation systems built around molecular motors and cytoskeletal filaments hold significant promise in the latter regard, recent proof-of-principle devices based on the microtubule-kinesin motor system have not matched the speed of existing methods. An attractive solution to overcome this limitation would be the use of myosin driven propulsion of actin filaments which offers motility one order of magnitude faster than the kinesin-microtubule system. Here, we realized a necessary requirement for the use of the actomyosin system in biosensing devices, namely covalent attachment of antibodies to actin filaments using heterobifunctional cross-linkers. We also demonstrated consistent and rapid myosin II driven transport where velocity and the fraction of motile actin filaments was negligibly affected by the presence of antibody-antigen complexes at rather high density (>20 µm(-1)). The results, however, also demonstrated that it was challenging to consistently achieve high density of functional antibodies along the actin filament, and optimization of the covalent coupling procedure to increase labeling density should be a major focus for future work. Despite the remaining challenges, the reported advances are important steps towards considerably faster nanoseparation than shown for previous molecular motor based devices, and enhanced miniaturization because of high bending flexibility of actin filaments.
Collapse
Affiliation(s)
- Saroj Kumar
- School of Natural Sciences, Linnaeus University, Kalmar, Sweden
| | | | - Malin Persson
- School of Natural Sciences, Linnaeus University, Kalmar, Sweden
| | - Mercy Lard
- The Nanometer Structure Consortium and Division of Solid State Physics, Lund University, Lund, Sweden
| | - Geertruy te Kronnie
- Department of Women’s and Children’s Health, University of Padua, Padova, Italy
| | - Heiner Linke
- The Nanometer Structure Consortium and Division of Solid State Physics, Lund University, Lund, Sweden
| | - Alf Månsson
- School of Natural Sciences, Linnaeus University, Kalmar, Sweden
- * E-mail:
| |
Collapse
|
34
|
Golden JP, Verbarg J, Howell PB, Shriver-Lake LC, Ligler FS. Automated processing integrated with a microflow cytometer for pathogen detection in clinical matrices. Biosens Bioelectron 2012; 40:10-6. [PMID: 22960010 DOI: 10.1016/j.bios.2012.08.015] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2012] [Revised: 08/04/2012] [Accepted: 08/07/2012] [Indexed: 02/01/2023]
Abstract
A spinning magnetic trap (MagTrap) for automated sample processing was integrated with a microflow cytometer capable of simultaneously detecting multiple targets to provide an automated sample-to-answer diagnosis in 40 min. After target capture on fluorescently coded magnetic microspheres, the magnetic trap automatically concentrated the fluorescently coded microspheres, separated the captured target from the sample matrix, and exposed the bound target sequentially to biotinylated tracer molecules and streptavidin-labeled phycoerythrin. The concentrated microspheres were then hydrodynamically focused in a microflow cytometer capable of 4-color analysis (two wavelengths for microsphere identification, one for light scatter to discriminate single microspheres and one for phycoerythrin bound to the target). A three-fold decrease in sample preparation time and an improved detection limit, independent of target preconcentration, was demonstrated for detection of Escherichia coli 0157:H7 using the MagTrap as compared to manual processing. Simultaneous analysis of positive and negative controls, along with the assay reagents specific for the target, was used to obtain dose-response curves, demonstrating the potential for quantification of pathogen load in buffer and serum.
Collapse
Affiliation(s)
- J P Golden
- Center for Bio/Molecular Science & Engineering, Naval Research Laboratory, Washington, DC 20375, USA
| | | | | | | | | |
Collapse
|
35
|
Translational actomyosin research: fundamental insights and applications hand in hand. J Muscle Res Cell Motil 2012; 33:219-33. [PMID: 22638606 PMCID: PMC3413815 DOI: 10.1007/s10974-012-9298-5] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2012] [Accepted: 05/01/2012] [Indexed: 12/24/2022]
Abstract
This review describes the development towards actomyosin based nanodevices taking a starting point in pioneering studies in the 1990s based on conventional in vitro motility assays. References are given to parallel developments using the kinesin–microtubule motor system. The early developments focused on achieving cargo-transportation using actin filaments as cargo-loaded shuttles propelled by surface-adsorbed heavy meromyosin along micro- and nanofabricated channels. These efforts prompted extensive studies of surface–motor interactions contributing with new insights of general relevance in surface and colloid chemistry. As a result of these early efforts, a range of complex devices have now emerged, spanning applications in medical diagnostics, biocomputation and formation of complex nanostructures by self-organization. In addition to giving a comprehensive account of the developments towards real-world applications an important goal of the present review is to demonstrate important connections between the applied studies and fundamental biophysical studies of actomyosin and muscle function. Thus the manipulation of the motor proteins towards applications has resulted in new insights into methodological aspects of the in vitro motiliy assay. Other developments have advanced the understanding of the dynamic materials properties of actin filaments.
Collapse
|
36
|
Raamanathan A, Simmons GW, Christodoulides N, Floriano PN, Furmaga WB, Redding SW, Lu KH, Bast RC, McDevitt JT. Programmable bio-nano-chip systems for serum CA125 quantification: toward ovarian cancer diagnostics at the point-of-care. Cancer Prev Res (Phila) 2012; 5:706-16. [PMID: 22490510 DOI: 10.1158/1940-6207.capr-11-0508] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
Point-of-care (POC) implementation of early detection and screening methodologies for ovarian cancer may enable improved survival rates through early intervention. Current laboratory-confined immunoanalyzers have long turnaround times and are often incompatible with multiplexing and POC implementation. Rapid, sensitive, and multiplexable POC diagnostic platforms compatible with promising early detection approaches for ovarian cancer are needed. To this end, we report the adaptation of the programmable bio-nano-chip (p-BNC), an integrated, microfluidic, and modular (programmable) platform for CA125 serum quantitation, a biomarker prominently implicated in multimodal and multimarker screening approaches. In the p-BNCs, CA125 from diseased sera (Bio) is sequestered and assessed with a fluorescence-based sandwich immunoassay, completed in the nano-nets (Nano) of sensitized agarose microbeads localized in individually addressable wells (Chip), housed in a microfluidic module, capable of integrating multiple sample, reagent and biowaste processing, and handling steps. Antibody pairs that bind to distinct epitopes on CA125 were screened. To permit efficient biomarker sequestration in a three-dimensional microfluidic environment, the p-BNC operating variables (incubation times, flow rates, and reagent concentrations) were tuned to deliver optimal analytical performance under 45 minutes. With short analysis times, competitive analytical performance (inter- and intra-assay precision of 1.2% and 1.9% and limit of detection of 1.0 U/mL) was achieved on this minisensor ensemble. Furthermore, validation with sera of patients with ovarian cancer (n = 20) showed excellent correlation (R(2) = 0.97) with gold-standard ELISA. Building on the integration capabilities of novel microfluidic systems programmed for ovarian cancer, the rapid, precise, and sensitive miniaturized p-BNC system shows strong promise for ovarian cancer diagnostics.
Collapse
Affiliation(s)
- Archana Raamanathan
- Departments of Bioengineering and Chemistry, Rice University, Houston, TX 77005, USA
| | | | | | | | | | | | | | | | | |
Collapse
|
37
|
Fu E, Yager P, Floriano PN, Christodoulides N, McDevitt JT. Perspective on diagnostics for global health. IEEE Pulse 2012; 2:40-50. [PMID: 22147068 DOI: 10.1109/mpul.2011.942766] [Citation(s) in RCA: 45] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Affiliation(s)
- Elain Fu
- Department of Bioengineering, University of Washington, Washington, USA.
| | | | | | | | | |
Collapse
|
38
|
Chou J, Lennart A, Wong J, Ali MF, Floriano PN, Christodoulides N, Camp J, McDevitt JT. Modeling analyte transport and capture in porous bead sensors. Anal Chem 2012; 84:2569-75. [PMID: 22250703 DOI: 10.1021/ac2022822] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Porous agarose microbeads, with high surface to volume ratios and high binding densities, are attracting attention as highly sensitive, affordable sensor elements for a variety of high performance bioassays. While such polymer microspheres have been extensively studied and reported on previously and are now moving into real-world clinical practice, very little work has been completed to date to model the convection, diffusion, and binding kinetics of soluble reagents captured within such fibrous networks. Here, we report the development of a three-dimensional computational model and provide the initial evidence for its agreement with experimental outcomes derived from the capture and detection of representative protein and genetic biomolecules in 290 μm porous beads. We compare this model to antibody-mediated capture of C-reactive protein and bovine serum albumin, along with hybridization of oligonucleotide sequences to DNA probes. These results suggest that, due to the porous interior of the agarose bead, internal analyte transport is both diffusion and convection based, and regardless of the nature of analyte, the bead interiors reveal an interesting trickle of convection-driven internal flow. On the basis of this model, the internal to external flow rate ratio is found to be in the range of 1:170 to 1:3100 for beads with agarose concentration ranging from 0.5% to 8% for the sensor ensembles here studied. Further, both model and experimental evidence suggest that binding kinetics strongly affect analyte distribution of captured reagents within the beads. These findings reveal that high association constants create a steep moving boundary in which unbound analytes are held back at the periphery of the bead sensor. Low association constants create a more shallow moving boundary in which unbound analytes diffuse further into the bead before binding. These models agree with experimental evidence and thus serve as a new tool set for the study of bioagent transport processes within a new class of medical microdevices.
Collapse
Affiliation(s)
- Jie Chou
- Department of Bioengineering, Rice University, Houston, Texas 77005, USA
| | | | | | | | | | | | | | | |
Collapse
|
39
|
Giannobile WV, McDevitt JT, Niedbala RS, Malamud D. Translational and clinical applications of salivary diagnostics. Adv Dent Res 2012; 23:375-80. [PMID: 21917748 DOI: 10.1177/0022034511420434] [Citation(s) in RCA: 62] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
There have been significant advances in techniques for the detection of biomarker signals in the oral cavity (e.g., ELISAs for proteins, PCR for RNA and DNA) as well as the engineering and development of microfluidic approaches to make oral-based point-of-care (POC) methods for the diagnosis for both local and systemic conditions a reality. In this section, we focus on three such approaches, namely, periodontal disease management, early markers for systemic diseases, and salivary markers useful for pharmacogenomic studies. Novel approaches using non-invasive, salivary samples and user-friendly devices offer results that are as sensitive and specific as laboratory-based analyses using blood or urine.
Collapse
Affiliation(s)
- W V Giannobile
- Department of Periodontics, Michigan Center for Oral Health Research, University of Michigan School of Dentistry, Ann Arbor, USA
| | | | | | | |
Collapse
|
40
|
|
41
|
Du N, Chou J, Kulla E, Floriano PN, Christodoulides N, McDevitt JT. A disposable bio-nano-chip using agarose beads for high performance immunoassays. Biosens Bioelectron 2011; 28:251-6. [PMID: 21852104 DOI: 10.1016/j.bios.2011.07.027] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2011] [Revised: 07/07/2011] [Accepted: 07/13/2011] [Indexed: 11/18/2022]
Abstract
This article reports on the fabrication of a disposable bio-nano-chip (BNC), a microfluidic device composed of polydimethylsiloxane (PDMS) and thiolene-based optical epoxy which is both cost-effective and suitable for high performance immunoassays. A novel room temperature (RT) bonding technique was utilized so as to achieve irreversible covalent bonding between PDMS and thiolene-based epoxy layers, while at the same time being compatible with the insertion of agarose bead sensors, selectively arranged in an array of pyramidal microcavities replicated in the thiolene thin film layer. In the sealed device, the bead-supporting epoxy film is sandwiched between two PDMS layers comprising of fluidic injection and drain channels. The agarose bead sensors used in the device are sensitized with anti-C-reactive protein (CRP) antibody, and a fluorescent sandwich-type immunoassay was run to characterize the performance of this device. Computational fluid dynamics (CFD) was used based on the device specifications to model the bead penetration. Experimental data revealed analyte penetration of the immunocomplex to 100 μm into the 280 μm diameter agarose beads, which correlated well with the simulation. A dose-response curve was obtained and the linear dynamic range of the assay was established over 1 ng/mL to 50 ng/mL with a limit of detection less than 1 ng/mL.
Collapse
Affiliation(s)
- Nan Du
- Rice Quantum Institute, Rice University, Houston, TX 77005, USA
| | | | | | | | | | | |
Collapse
|
42
|
Abstract
Microfluidic devices exhibit a great promising development in clinical diagnosis and disease screening due to their advantages of precise controlling of fluid flow, requirement of miniamount sample, rapid reaction speed and convenient integration. In this paper, the improvements of microfluidic diagnostic technologies in recent years are reviewed. The applications and developments of on-chip disease marker detection, microfluidic cell selection and cell drug metabolism, and diagnostic micro-devices are discussed.
Collapse
Affiliation(s)
- Haifang Li
- School of Science, Beijing University of Chemical Technology, Beijing 100029, China
| | | | | |
Collapse
|
43
|
Jokerst JV, Miao Z, Zavaleta C, Cheng Z, Gambhir SS. Affibody-functionalized gold-silica nanoparticles for Raman molecular imaging of the epidermal growth factor receptor. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2011; 7:625-633. [PMID: 21302357 DOI: 10.1002/smll.v7.5] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/16/2010] [Indexed: 05/19/2023]
Abstract
The affibody functionalization of fluorescent surface-enhanced Raman scattering gold-silica nanoparticles as multimodal contrast agents for molecular imaging specific to epidermal growth factor receptor (EGFR) is reported. This nanoparticle bioconjugate reports EGFR-positive A431 tumors with a signal nearly 35-fold higher than EGFR-negative MDA-435S tumors. The low-level EGFR expression in adjacent healthy tissue is 7-fold lower than in the positive tumors. Validation via competitive inhibition reduces the signal by a factor of six, and independent measurement of EGFR via flow cytometry correlates at R(2) = 0.92.
Collapse
Affiliation(s)
- Jesse V Jokerst
- Molecular Imaging Program at Stanford, Department of Radiology, Stanford, CA 94305, USA
| | | | | | | | | |
Collapse
|
44
|
Jokerst JV, Miao Z, Zavaleta C, Cheng Z, Gambhir SS. Affibody-functionalized gold-silica nanoparticles for Raman molecular imaging of the epidermal growth factor receptor. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2011; 7:625-33. [PMID: 21302357 PMCID: PMC3386295 DOI: 10.1002/smll.201002291] [Citation(s) in RCA: 87] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/16/2010] [Indexed: 05/17/2023]
Abstract
The affibody functionalization of fluorescent surface-enhanced Raman scattering gold-silica nanoparticles as multimodal contrast agents for molecular imaging specific to epidermal growth factor receptor (EGFR) is reported. This nanoparticle bioconjugate reports EGFR-positive A431 tumors with a signal nearly 35-fold higher than EGFR-negative MDA-435S tumors. The low-level EGFR expression in adjacent healthy tissue is 7-fold lower than in the positive tumors. Validation via competitive inhibition reduces the signal by a factor of six, and independent measurement of EGFR via flow cytometry correlates at R(2) = 0.92.
Collapse
Affiliation(s)
- Jesse V. Jokerst
- Molecular Imaging Program at Stanford, Department of Radiology, Department of Bioengineering, Materials Science and Engineering and Bio-X, 318 Campus Drive, Stanford, CA 94305, USA
| | - Zheng Miao
- Molecular Imaging Program at Stanford, Department of Radiology, Department of Bioengineering, Materials Science and Engineering and Bio-X, 318 Campus Drive, Stanford, CA 94305, USA
| | - Cristina Zavaleta
- Molecular Imaging Program at Stanford, Department of Radiology, Department of Bioengineering, Materials Science and Engineering and Bio-X, 318 Campus Drive, Stanford, CA 94305, USA
| | - Zhen Cheng
- Molecular Imaging Program at Stanford, Department of Radiology, Department of Bioengineering, Materials Science and Engineering and Bio-X, 318 Campus Drive, Stanford, CA 94305, USA
| | - Sanjiv S. Gambhir
- Molecular Imaging Program at Stanford, Department of Radiology, Department of Bioengineering, Materials Science and Engineering and Bio-X, 318 Campus Drive, Stanford, CA 94305, USA
| |
Collapse
|
45
|
Jokerst JV, Chou J, Camp JP, Wong J, Lennart A, Pollard AA, Floriano PN, Christodoulides N, Simmons GW, Zhou Y, Ali MF, McDevitt JT. Location of biomarkers and reagents within agarose beads of a programmable bio-nano-chip. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2011; 7:613-24. [PMID: 21290601 PMCID: PMC3397282 DOI: 10.1002/smll.201002089] [Citation(s) in RCA: 42] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/20/2010] [Indexed: 05/22/2023]
Abstract
The slow development of cost-effective medical microdevices with strong analytical performance characteristics is due to a lack of selective and efficient analyte capture and signaling. The recently developed programmable bio-nano-chip (PBNC) is a flexible detection device with analytical behavior rivaling established macroscopic methods. The PBNC system employs ≈300 μm-diameter bead sensors composed of agarose "nanonets" that populate a microelectromechanical support structure with integrated microfluidic elements. The beads are an efficient and selective protein-capture medium suitable for the analysis of complex fluid samples. Microscopy and computational studies probe the 3D interior of the beads. The relative contributions that the capture and detection of moieties, analyte size, and bead porosity make to signal distribution and intensity are reported. Agarose pore sizes ranging from 45 to 620 nm are examined and those near 140 nm provide optimal transport characteristics for rapid (<15 min) tests. The system exhibits efficient (99.5%) detection of bead-bound analyte along with low (≈2%) nonspecific immobilization of the detection probe for carcinoembryonic antigen assay. Furthermore, the role analyte dimensions play in signal distribution is explored, and enhanced methods for assay building that consider the unique features of biomarker size are offered.
Collapse
Affiliation(s)
- Jesse V. Jokerst
- Departments of Chemistry and Biochemistry, University of Texas at Austin, Austin, TX 78712, USA
| | - Jie Chou
- Departments of Bioengineering and Chemistry, Rice University, 6500 Main Street, Houston, TX 77030, USA
| | - James P. Camp
- Departments of Chemistry and Biochemistry, University of Texas at Austin, Austin, TX 78712, USA
| | - Jorge Wong
- Departments of Chemistry and Biochemistry, University of Texas at Austin, Austin, TX 78712, USA
| | - Alexis Lennart
- Departments of Chemistry and Biochemistry, University of Texas at Austin, Austin, TX 78712, USA
| | - Amanda A. Pollard
- Departments of Chemistry and Biochemistry, University of Texas at Austin, Austin, TX 78712, USA
| | - Pierre N. Floriano
- Departments of Bioengineering and Chemistry, Rice University, 6500 Main Street, Houston, TX 77030, USA
| | - Nicolaos Christodoulides
- Departments of Bioengineering and Chemistry, Rice University, 6500 Main Street, Houston, TX 77030, USA
| | - Glennon W. Simmons
- Departments of Bioengineering and Chemistry, Rice University, 6500 Main Street, Houston, TX 77030, USA
| | - Yanjie Zhou
- Departments of Chemistry and Biochemistry, University of Texas at Austin, Austin, TX 78712, USA
| | - Mehnaaz F. Ali
- Departments of Chemistry and Biochemistry, University of Texas at Austin, Austin, TX 78712, USA
| | - John T. McDevitt
- Departments of Bioengineering and Chemistry, Rice University, 6500 Main Street, Houston, TX 77030, USA
| |
Collapse
|
46
|
Abstract
Profiling of protein biomarkers is powerful for the analysis of complex proteomes altered during the progression of diseases. Lab-on-a-chip technologies can potentially provide the throughput and efficiency required for point-of-care and clinical applications. While initial studies utilized 1D microchip separation techniques, researchers have recently developed novel 2D microchip separation platforms with the ability to profile thousands of proteins more effectively. Despite advancements in lab-on-a-chip technologies, very few reports have demonstrated a point-of-care microchip-based profiling of proteins. In this review, recent progress in 1D and 2D microchip profiling of protein mixtures of a biological sample with potential point-of-care applications are discussed. A selection of recent microchip immunoassay-based techniques is also highlighted.
Collapse
|