1
|
Zhang H, Jiang H, Liu X, Wang X. A review of innovative electrochemical strategies for bioactive molecule detection and cell imaging: Current advances and challenges. Anal Chim Acta 2024; 1285:341920. [PMID: 38057043 DOI: 10.1016/j.aca.2023.341920] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2023] [Revised: 10/13/2023] [Accepted: 10/14/2023] [Indexed: 12/08/2023]
Abstract
Cellular heterogeneity poses a major challenge for tumor theranostics, requiring high-resolution intercellular bioanalysis strategies. Over the past decades, the advantages of electrochemical analysis, such as high sensitivity, good spatio-temporal resolution, and ease of use, have made it the preferred method to uncover cellular differences. To inspire more creative research, herein, we highlight seminal works in electrochemical techniques for biomolecule analysis and bioimaging. Specifically, micro/nano-electrode-based electrochemical techniques enable real-time quantitative analysis of electroactive substances relevant to life processes in the micro-nanostructure of cells and tissues. Nanopore-based technique plays a vital role in biosensing by utilizing nanoscale pores to achieve high-precision detection and analysis of biomolecules with exceptional sensitivity and single-molecule resolution. Electrochemiluminescence (ECL) technology is utilized for real-time monitoring of the behavior and features of individual cancer cells, enabling observation of their dynamic processes due to its capability of providing high-resolution and highly sensitive bioimaging of cells. Particularly, scanning electrochemical microscopy (SECM) and scanning ion conductance microscopy (SICM) which are widely used in real-time observation of cell surface biological processes and three-dimensional imaging of micro-nano structures, such as metabolic activity, ion channel activity, and cell morphology are introduced in this review. Furthermore, the expansion of the scope of cellular electrochemistry research by innovative functionalized electrodes and electrochemical imaging models and strategies to address future challenges and potential applications is also discussed in this review.
Collapse
Affiliation(s)
- Hao Zhang
- State Key Laboratory of Digital Medical Engineering, School of Biological Science and Medical Engineering, Southeast University, Nanjing, Jiangsu 210096, China
| | - Hui Jiang
- State Key Laboratory of Digital Medical Engineering, School of Biological Science and Medical Engineering, Southeast University, Nanjing, Jiangsu 210096, China
| | - Xiaohui Liu
- State Key Laboratory of Digital Medical Engineering, School of Biological Science and Medical Engineering, Southeast University, Nanjing, Jiangsu 210096, China.
| | - Xuemei Wang
- State Key Laboratory of Digital Medical Engineering, School of Biological Science and Medical Engineering, Southeast University, Nanjing, Jiangsu 210096, China.
| |
Collapse
|
2
|
Lin TE, Darvishi S. A Brief Review of In Situ and Operando Electrochemical Analysis of Bacteria by Scanning Probes. BIOSENSORS 2023; 13:695. [PMID: 37504094 PMCID: PMC10377567 DOI: 10.3390/bios13070695] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/10/2023] [Revised: 06/23/2023] [Accepted: 06/28/2023] [Indexed: 07/29/2023]
Abstract
Bacteria are similar to social organisms that engage in critical interactions with one another, forming spatially structured communities. Despite extensive research on the composition, structure, and communication of bacteria, the mechanisms behind their interactions and biofilm formation are not yet fully understood. To address this issue, scanning probe techniques such as atomic force microscopy (AFM), scanning electrochemical microscopy (SECM), scanning electrochemical cell microscopy (SECCM), and scanning ion-conductance microscopy (SICM) have been utilized to analyze bacteria. This review article focuses on summarizing the use of electrochemical scanning probes for investigating bacteria, including analysis of electroactive metabolites, enzymes, oxygen consumption, ion concentrations, pH values, biofilms, and quorum sensing molecules to provide a better understanding of bacterial interactions and communication. SECM has been combined with other techniques, such as AFM, inverted optical microscopy, SICM, and fluorescence microscopy. This allows a comprehensive study of the surfaces of bacteria while also providing more information on their metabolic activity. In general, the use of scanning probes for the detection of bacteria has shown great promise and has the potential to provide a powerful tool for the study of bacterial physiology and the detection of bacterial infections.
Collapse
Affiliation(s)
- Tzu-En Lin
- Institute of Biomedical Engineering, Department of Electrical and Computer Engineering, National Yang Ming Chiao Tung University, Hsinchu 30010, Taiwan
| | - Sorour Darvishi
- Department of Electrical Engineering and Computer Sciences, University of California, Berkeley, CA 94720, USA
- Berkeley Sensor and Actuator Center, University of California, Berkeley, CA 94720, USA
| |
Collapse
|
3
|
Mishra A, Sarbapalli D, Rodríguez O, Rodríguez-López J. Electrochemical Imaging of Interfaces in Energy Storage via Scanning Probe Methods: Techniques, Applications, and Prospects. ANNUAL REVIEW OF ANALYTICAL CHEMISTRY (PALO ALTO, CALIF.) 2023; 16:93-115. [PMID: 37068746 DOI: 10.1146/annurev-anchem-091422-110703] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Developing a deeper understanding of dynamic chemical, electronic, and morphological changes at interfaces is key to solving practical issues in electrochemical energy storage systems (EESSs). To unravel this complexity, an assortment of tools with distinct capabilities and spatiotemporal resolutions have been used to creatively visualize interfacial processes as they occur. This review highlights how electrochemical scanning probe techniques (ESPTs) such as electrochemical atomic force microscopy, scanning electrochemical microscopy, scanning ion conductance microscopy, and scanning electrochemical cell microscopy are uniquely positioned to address these challenges in EESSs. We describe the operating principles of ESPTs, focusing on the inspection of interfacial structure and chemical processes involved in Li-ion batteries and beyond. We discuss current examples, performance limitations, and complementary ESPTs. Finally, we discuss prospects for imaging improvements and deep learning for automation. We foresee that ESPTs will play an enabling role in advancing EESSs as we transition to renewable energies.
Collapse
Affiliation(s)
- Abhiroop Mishra
- Department of Chemistry, University of Illinois Urbana-Champaign, Urbana, Illinois, USA;
| | - Dipobrato Sarbapalli
- Department of Chemistry, University of Illinois Urbana-Champaign, Urbana, Illinois, USA;
| | - Oliver Rodríguez
- Department of Chemistry, University of Illinois Urbana-Champaign, Urbana, Illinois, USA;
| | | |
Collapse
|
4
|
Santana Santos C, Jaato BN, Sanjuán I, Schuhmann W, Andronescu C. Operando Scanning Electrochemical Probe Microscopy during Electrocatalysis. Chem Rev 2023; 123:4972-5019. [PMID: 36972701 PMCID: PMC10168669 DOI: 10.1021/acs.chemrev.2c00766] [Citation(s) in RCA: 15] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/29/2023]
Abstract
Scanning electrochemical probe microscopy (SEPM) techniques can disclose the local electrochemical reactivity of interfaces in single-entity and sub-entity studies. Operando SEPM measurements consist of using a SEPM tip to investigate the performance of electrocatalysts, while the reactivity of the interface is simultaneously modulated. This powerful combination can correlate electrochemical activity with changes in surface properties, e.g., topography and structure, as well as provide insight into reaction mechanisms. The focus of this review is to reveal the recent progress in local SEPM measurements of the catalytic activity of a surface toward the reduction and evolution of O2 and H2 and electrochemical conversion of CO2. The capabilities of SEPMs are showcased, and the possibility of coupling other techniques to SEPMs is presented. Emphasis is given to scanning electrochemical microscopy (SECM), scanning ion conductance microscopy (SICM), electrochemical scanning tunneling microscopy (EC-STM), and scanning electrochemical cell microscopy (SECCM).
Collapse
Affiliation(s)
- Carla Santana Santos
- Analytical Chemistry - Center for Electrochemical Sciences (CES), Faculty of Chemistry and Biochemistry, Ruhr University Bochum, Universitätsstr. 150, D-44780 Bochum, Germany
| | - Bright Nsolebna Jaato
- Technical Chemistry III, Center for Nanointegration Duisburg-Essen (CENIDE), University of Duisburg-Essen Carl-Benz-Straße 199, 47057 Duisburg, Germany
| | - Ignacio Sanjuán
- Technical Chemistry III, Center for Nanointegration Duisburg-Essen (CENIDE), University of Duisburg-Essen Carl-Benz-Straße 199, 47057 Duisburg, Germany
| | - Wolfgang Schuhmann
- Analytical Chemistry - Center for Electrochemical Sciences (CES), Faculty of Chemistry and Biochemistry, Ruhr University Bochum, Universitätsstr. 150, D-44780 Bochum, Germany
| | - Corina Andronescu
- Technical Chemistry III, Center for Nanointegration Duisburg-Essen (CENIDE), University of Duisburg-Essen Carl-Benz-Straße 199, 47057 Duisburg, Germany
| |
Collapse
|
5
|
Sciurti E, Biscaglia F, Prontera C, Giampetruzzi L, Blasi L, Francioso L. Nanoelectrodes for Intracellular and Intercellular electrochemical detection: working principles, fabrication techniques and applications. J Electroanal Chem (Lausanne) 2022. [DOI: 10.1016/j.jelechem.2022.117125] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
|
6
|
Abstract
Understanding the structure-activity relationship at electrochemical interfaces is crucial in improving the performance of practical electrochemical devices, ranging from fuel cells, electrolyzers, and batteries to electrochemical sensors. However, functional electrochemical interfaces are often complex and contain various surface structures, creating heterogeneity in electrochemical activity. In this Perspective, we highlight the role of heterogeneity in electrochemistry, especially in the context of electrocatalysis. Current methods for revealing the heterogeneity at electrochemical interfaces, including nanoelectrochemistry tools and single-entity approaches, are discussed. Lastly, we provide perspectives on what one can learn by studying heterogeneity and how one can use heterogeneity to design more efficient electrochemical devices.
Collapse
Affiliation(s)
- C Hyun Ryu
- Department of Chemistry, The University of Texas at Austin, Austin, Texas 78712, United States
| | - Hyein Lee
- Department of Chemistry, The University of Texas at Austin, Austin, Texas 78712, United States
| | - Heekwon Lee
- Department of Chemistry, The University of Texas at Austin, Austin, Texas 78712, United States
| | - Hang Ren
- Department of Chemistry, The University of Texas at Austin, Austin, Texas 78712, United States
| |
Collapse
|
7
|
Steady-state voltammetric characterization and simulation-aided study of the mass transfer enhancement at conical W/WO2 ultramicroelectrodes. Electrochim Acta 2022. [DOI: 10.1016/j.electacta.2021.139524] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
8
|
Abstract
Scanning ion conductance microscopy (SICM) has emerged as a versatile tool for studies of interfaces in biology and materials science with notable utility in biophysical and electrochemical measurements. The heart of the SICM is a nanometer-scale electrolyte filled glass pipette that serves as a scanning probe. In the initial conception, manipulations of ion currents through the tip of the pipette and appropriate positioning hardware provided a route to recording micro- and nanoscopic mapping of the topography of surfaces. Subsequent advances in instrumentation, probe design, and methods significantly increased opportunities for SICM beyond recording topography. Hybridization of SICM with coincident characterization techniques such as optical microscopy and faradaic electrodes have brought SICM to the forefront as a tool for nanoscale chemical measurement for a wide range of applications. Modern approaches to SICM realize an important tool in analytical, bioanalytical, biophysical, and materials measurements, where significant opportunities remain for further exploration. In this review, we chronicle the development of SICM from the perspective of both the development of instrumentation and methods and the breadth of measurements performed.
Collapse
Affiliation(s)
- Cheng Zhu
- Department of Chemistry, Indiana University, 800 E. Kirkwood Avenue, Bloomington, Indiana 47405, United States
| | - Kaixiang Huang
- Department of Chemistry, Indiana University, 800 E. Kirkwood Avenue, Bloomington, Indiana 47405, United States
| | - Natasha P Siepser
- Department of Chemistry, Indiana University, 800 E. Kirkwood Avenue, Bloomington, Indiana 47405, United States
| | - Lane A Baker
- Department of Chemistry, Indiana University, 800 E. Kirkwood Avenue, Bloomington, Indiana 47405, United States
| |
Collapse
|
9
|
Utagawa Y, Hiramoto K, Nashimoto Y, Ino K, Shiku H. In vitro electrochemical assays for vascular cells and organs. ELECTROCHEMICAL SCIENCE ADVANCES 2021. [DOI: 10.1002/elsa.202100089] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022] Open
Affiliation(s)
- Yoshinobu Utagawa
- Graduate School of Environmental Studies Tohoku University Aoba‐ku Sendai Japan
| | - Kaoru Hiramoto
- Graduate School of Environmental Studies Tohoku University Aoba‐ku Sendai Japan
| | - Yuji Nashimoto
- Frontier Research Institute for Interdisciplinary Sciences Tohoku University Aoba‐ku Sendai Japan
- Graduate School of Engineering Tohoku University Aoba‐ku Sendai Japan
| | - Kosuke Ino
- Graduate School of Engineering Tohoku University Aoba‐ku Sendai Japan
| | - Hitoshi Shiku
- Graduate School of Engineering Tohoku University Aoba‐ku Sendai Japan
| |
Collapse
|
10
|
A cost-efficient approach for simultaneous scanning electrochemical microscopy and scanning ion conductance microscopy. MONATSHEFTE FUR CHEMIE 2020. [DOI: 10.1007/s00706-020-02635-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
Abstract
AbstractA novel and cost-efficient probe fabrication method yielding probes for performing simultaneous scanning electrochemical microscopy (SECM) and scanning ion conductance microscopy (SICM) is presented. Coupling both techniques allows distinguishing topographical and electrochemical activity information obtained by SECM. Probes were prepared by deposition of photoresist onto platinum-coated, pulled fused silica capillaries, which resulted in a pipette probe with an integrated ring ultramicroelectrode. The fabricated probes were characterized by means of cyclic voltammetry and scanning electron microscopy. The applicability of probes was demonstrated by measuring and distinguishing topography and electrochemical activity of a model substrate. In addition, porous boron-doped diamond samples were investigated via simultaneously performed SECM and SICM.
Graphic abstract
Collapse
|
11
|
Jiao Y, Zhuang J, Zheng Q, Liao X. A High Accuracy Ion Conductance Imaging Method Based on the Approach Curve Spectrum. Ultramicroscopy 2020; 215:113025. [PMID: 32485394 DOI: 10.1016/j.ultramic.2020.113025] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/29/2020] [Revised: 04/28/2020] [Accepted: 05/16/2020] [Indexed: 01/13/2023]
Abstract
Scanning ion conductance microscopy (SICM), as an emerging non-contact in situ topography measurement tool with nano resolution, has been increasingly used in recent years in biomedicine, electrochemistry and materials science. In the conventional measurement method of SICM, the sample topography is constructed according to the position of the probe at the feedback threshold of the ion current. Nevertheless, for different structures, a constant threshold cannot maintain a constant probe-sample distance. This phenomenon makes the measurement topography inconsistent with the real sample surface. In order to solve this problem and improve the measurement accuracy of SICM, a new ion conductance imaging method based on the approach curve spectrum is proposed in this work. In the new method, the local feature around the measurement point is firstly evaluated according to the change rate of ion current. Secondly, based on the local feature, the corresponding approach curve is searched from the prior approach curve spectrum to accurately evaluate the distance between the probe and the sample. Finally, the sample topography is constructed by the probe position subtracting the probe-sample distance. In this paper, we verify the feasibility of the new imaging method by combining finite element theory and experiments. To examine the measurement accuracy, the standard strip silicon and cylindrical polydimethylsiloxane (PDMS) samples are tested, and the improved imaging method can obtain the topography closer to the real samples and reduce the volumetric measurement error by 5.4%. The implementation of the new imaging method will further promote SICM application in related research fields.
Collapse
Affiliation(s)
- Yangbohan Jiao
- Key Laboratory of Education Ministry for Modern Design Rotor-Bearing System, Xi'an Jiaotong University, Xi'an 710049, China; School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an 710049, China
| | - Jian Zhuang
- Key Laboratory of Education Ministry for Modern Design Rotor-Bearing System, Xi'an Jiaotong University, Xi'an 710049, China; School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an 710049, China.
| | - Qiangqiang Zheng
- Key Laboratory of Education Ministry for Modern Design Rotor-Bearing System, Xi'an Jiaotong University, Xi'an 710049, China; School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an 710049, China
| | - Xiaobo Liao
- Key Laboratory of Education Ministry for Modern Design Rotor-Bearing System, Xi'an Jiaotong University, Xi'an 710049, China; School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an 710049, China; School of Manufacturing Science and Engineering, Key Laboratory of Testing Technology for Manufacturing Process, Ministry of Education, Southwest University of Science and Technology, Mianyang 621010, China
| |
Collapse
|
12
|
Synchronous Electrical Conductance‐ and Electron Tunnelling‐Scanning Electrochemical Microscopy Measurements. ChemElectroChem 2020. [DOI: 10.1002/celc.201901721] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
|
13
|
Atomic force microscopy - Scanning electrochemical microscopy (AFM-SECM) for nanoscale topographical and electrochemical characterization: Principles, applications and perspectives. Electrochim Acta 2020. [DOI: 10.1016/j.electacta.2019.135472] [Citation(s) in RCA: 28] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/18/2023]
|
14
|
Dorfi AE, Kuo HW, Smirnova V, Wright J, Esposito DV. Design and operation of a scanning electrochemical microscope for imaging with continuous line probes. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2019; 90:083702. [PMID: 31472628 DOI: 10.1063/1.5095951] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/13/2019] [Accepted: 07/18/2019] [Indexed: 06/10/2023]
Abstract
This article describes a home-built scanning electrochemical microscope capable of achieving high areal imaging rates through the use of continuous line probes (CLPs) and compressed sensing (CS) image reconstruction. The CLP is a nonlocal probe consisting of a band electrode, where the achievable spatial resolution is set by the thickness of the band and the achievable imaging rate is largely determined by its width. A combination of linear and rotational motors allows for CLP scanning at different angles over areas up to 25 cm2 to generate the raw signal necessary to reconstruct the desired electrochemical image using CS signal analysis algorithms. Herein, we provide detailed descriptions of CLP fabrication, microscope design, and the procedures used to carry out scanning electrochemical microscopy imaging with CLPs. In order to illustrate the basic operating procedures for the microscope, line scans and images measured in the substrate generation-probe-collection mode for flat samples containing platinum disk electrodes are presented. These exemplary measurements illustrate methods for calibrating the positioning system, positioning and cleaning the CLP, and verifying proper positioning/probe sensitivity along its length.
Collapse
Affiliation(s)
- Anna E Dorfi
- Department of Chemical Engineering, Columbia Electrochemical Energy Center, Lenfest Center for Sustainable Energy, Columbia University in the City of New York, New York, New York 10027, USA
| | - Han-Wen Kuo
- Department of Electrical Engineering, Data Science Institute, Columbia University in the City of New York, New York, New York 10027, USA
| | - Vera Smirnova
- Department of Chemical Engineering, Columbia Electrochemical Energy Center, Lenfest Center for Sustainable Energy, Columbia University in the City of New York, New York, New York 10027, USA
| | - John Wright
- Department of Electrical Engineering, Data Science Institute, Columbia University in the City of New York, New York, New York 10027, USA
| | - Daniel V Esposito
- Department of Chemical Engineering, Columbia Electrochemical Energy Center, Lenfest Center for Sustainable Energy, Columbia University in the City of New York, New York, New York 10027, USA
| |
Collapse
|
15
|
Kolagatla S, Subramanian P, Schechter A. Simultaneous Mapping of Oxygen Reduction Activity and Hydrogen Peroxide Generation on Electrocatalytic Surfaces. CHEMSUSCHEM 2019; 12:2708-2714. [PMID: 30972916 DOI: 10.1002/cssc.201900656] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/06/2019] [Revised: 04/04/2019] [Indexed: 06/09/2023]
Abstract
Electrochemical scanning probe microscopies have become valuable experimental tools, owing to their capability of capturing topographic features in addition to mapping the electrochemical activity of nanoscale oxygen reduction catalysts. However, most scanning probe techniques lack the ability to correlate topographic features with the electrochemical oxygen reduction and peroxide formation in real time. In this report, we show that it is indeed possible to construct high-resolution catalytic current maps at an electrified solid-liquid interface by placing a specially made Au-coated SiO2 Pt atomic force microscopy and scanning electrochemical microscopy (AFM-SECM) dual electrode tip approximately 4-8 nm above the reaction center. The catalytic current measured every 16 nm and high collection efficiency (≈90 %) of the reverse current of peroxide byproducts was also demonstrated with the help of the dual electrode tip. Simultaneous oxygen reduction and intermediate peroxide oxidation current mapping was demonstrated using this Au-coated SiO2 Pt probe on two model surfaces, namely highly oriented pyrolytic graphite and Pt nanoparticles (NPs) supported on a glassy carbon surface.
Collapse
Affiliation(s)
| | | | - Alex Schechter
- Department of Chemical Sciences, Ariel University, Ariel, 40700, Israel
| |
Collapse
|
16
|
Shin M, Wang Y, Borgus JR, Venton BJ. Electrochemistry at the Synapse. ANNUAL REVIEW OF ANALYTICAL CHEMISTRY (PALO ALTO, CALIF.) 2019; 12:297-321. [PMID: 30707593 PMCID: PMC6989097 DOI: 10.1146/annurev-anchem-061318-115434] [Citation(s) in RCA: 45] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
Electrochemical measurements of neurotransmitters provide insight into the dynamics of neurotransmission. In this review, we describe the development of electrochemical measurements of neurotransmitters and how they started with extrasynaptic measurements but now are pushing toward synaptic measurements. Traditionally, biosensors or fast-scan cyclic voltammetry have monitored extrasynaptic levels of neurotransmitters, such as dopamine, serotonin, adenosine, glutamate, and acetylcholine. Amperometry and electrochemical cytometry techniques have revealed mechanisms of exocytosis, suggesting partial release. Advances in nanoelectrodes now allow spatially resolved, electrochemical measurements in a synapse, which is only 20-100 nm wide. Synaptic measurements of dopamine and acetylcholine have been made. In this article, electrochemical measurements are also compared to optical imaging and mass spectrometry measurements, and while these other techniques provide enhanced spatial or chemical information, electrochemistry is best at monitoring real-time neurotransmission. Future challenges include combining electrochemistry with these other techniques in order to facilitate multisite and multianalyte monitoring.
Collapse
Affiliation(s)
| | | | - Jason R Borgus
- Department of Chemistry, University of Virginia, Charlottesville, Virginia 22901, USA;
| | - B Jill Venton
- Department of Chemistry, University of Virginia, Charlottesville, Virginia 22901, USA;
| |
Collapse
|
17
|
Scanning electrochemical microscopy in the development of enzymatic sensors and immunosensors. Biosens Bioelectron 2019; 141:111411. [PMID: 31228730 DOI: 10.1016/j.bios.2019.111411] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2019] [Revised: 05/24/2019] [Accepted: 06/03/2019] [Indexed: 01/05/2023]
Abstract
Scanning electrochemical microscopy (SECM) is very useful, non-invasive tool for the analysis of surfaces pre-modified with biomolecules or by whole cells. This review focuses on the application of SECM technique for the analysis of surfaces pre-modified with enzymes (horseradish peroxidase, alkaline phosphatase and glucose oxidase) or labelled with antibody-enzyme conjugates. The working principles and operating modes of SECM are outlined. The applicability of feedback, generation-collection and redox competition modes of SECM on surfaces modified by enzymes or labelled with antibody-enzyme conjugates is discussed. SECM is important in the development of miniaturized bioanalytical systems with enzymes, since it can provide information about the local enzyme activity. Technical challenges and advantages of SECM, experimental parameters, used enzymes and redox mediators, immunoassay formats and analytical parameters of enzymatic SECM sensors and immunosensors are reviewed.
Collapse
|
18
|
Kang G, Yang M, Mattei MS, Schatz GC, Van Duyne RP. In Situ Nanoscale Redox Mapping Using Tip-Enhanced Raman Spectroscopy. NANO LETTERS 2019; 19:2106-2113. [PMID: 30763517 DOI: 10.1021/acs.nanolett.9b00313] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/07/2023]
Abstract
Electrochemical atomic force microscopy tip-enhanced Raman spectroscopy (EC-AFM-TERS) was used for the first time to spatially resolve local heterogeneity in redox behavior on an electrode surface in situ and at the nanoscale. A structurally well-defined Au(111) nanoplate located on a polycrystalline ITO substrate was studied to examine nanoscale redox contrast across the two electrode materials. By monitoring the TERS intensity of adsorbed Nile Blue (NB) molecules on the electrode surface, TERS maps were acquired with different applied potentials. The EC-TERS maps showed a spatial contrast in TERS intensity between Au and ITO. TERS line scans near the edge of a 20 nm-thick Au nanoplate demonstrated a spatial resolution of 81 nm under an applied potential of -0.1 V vs Ag/AgCl. The intensities from the TERS maps at various applied potentials followed Nernstian behavior, and a formal potential ( E0') map was constructed by fitting the TERS intensity at each pixel to the Nernst equation. Clear nanoscale spatial contrast between the Au and ITO regions was observed in the E0' map. In addition, statistical analysis of the E0' map identified a statistically significant 4 mV difference in E0' on Au vs ITO. Electrochemical heterogeneity was also evident in the E0' distribution, as a bimodal distribution was observed in E0' on polycrystalline ITO, but not on gold. A direct comparison between an AFM friction image and the E0' map resolved the electrochemical behavior of individual ITO grains with a spatial resolution of ∼40 nm. The variation in E0' was attributed to different local surface charges on the ITO grains. Such site-specific electrochemical information with nanoscale spatial and few mV voltage resolutions is not available using ensemble spectroelectrochemical methods. We expect that in situ redox mapping at the nanoscale using EC-AFM-TERS will have a crucial impact on understanding the role of nanoscale surface features in applications such as electrocatalysis.
Collapse
Affiliation(s)
- Gyeongwon Kang
- Department of Chemistry , Northwestern University , Evanston , Illinois 60208 , United States
| | - Muwen Yang
- Department of Chemistry , Northwestern University , Evanston , Illinois 60208 , United States
| | - Michael S Mattei
- Department of Chemistry , Northwestern University , Evanston , Illinois 60208 , United States
| | - George C Schatz
- Department of Chemistry , Northwestern University , Evanston , Illinois 60208 , United States
| | - Richard P Van Duyne
- Department of Chemistry , Northwestern University , Evanston , Illinois 60208 , United States
| |
Collapse
|
19
|
Ivanova R, Benton DCH, Munye MM, Rangseesorranan S, Hart SL, Moss GWJ. A Nanosensor Toolbox for Rapid, Label-Free Measurement of Airway Surface Liquid and Epithelial Cell Function. ACS APPLIED MATERIALS & INTERFACES 2019; 11:8731-8739. [PMID: 30648848 DOI: 10.1021/acsami.8b14122] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
Ciliated lung epithelial cells and the airway surface liquid (ASL) comprise one of the body's most important protective systems. This system is finely tuned, and perturbations to ASL rheology, ASL depth, ASL pH, the transepithelial potential, and the cilia beat frequency are all associated with disease pathology. Further, these apparently distinct properties interact with each other in a complex manner. For example, changes in ASL rheology can result from altered mucin secretion, changes in ASL pH, or changes in ASL depth. Thus, one of the great challenges in trying to understand airway pathology is that the properties of the ASL/epithelial cell system need to be assessed near-simultaneously and without perturbing the sample. Here, we show that nanosensor probes mounted on a scanning ion conductance microscope make this possible for the first time, without any need for labeling. We also demonstrate that ASL from senescence-retarded human bronchial epithelial cells retains its native properties. Our results demonstrate that by using a nanosensor approach, it is possible to pursue faster, more accurate, more coherent, and more informative studies of ASL and airway epithelia in health and disease.
Collapse
|
20
|
Hui J, Gossage ZT, Sarbapalli D, Hernández-Burgos K, Rodríguez-López J. Advanced Electrochemical Analysis for Energy Storage Interfaces. Anal Chem 2018; 91:60-83. [PMID: 30428255 DOI: 10.1021/acs.analchem.8b05115] [Citation(s) in RCA: 31] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Affiliation(s)
- Jingshu Hui
- Department of Chemistry , University of Illinois at Urbana-Champaign , 600 South Mathews Avenue , Urbana , Illinois 61801 , United States
| | - Zachary T Gossage
- Department of Chemistry , University of Illinois at Urbana-Champaign , 600 South Mathews Avenue , Urbana , Illinois 61801 , United States
| | - Dipobrato Sarbapalli
- Department of Materials Science and Engineering , University of Illinois at Urbana-Champaign , 1304 West Green Street , Urbana , Illinois 61801 , United States
| | - Kenneth Hernández-Burgos
- Department of Chemistry , University of Illinois at Urbana-Champaign , 600 South Mathews Avenue , Urbana , Illinois 61801 , United States.,Beckman Institute for Advanced Science and Technology , 405 North Mathews Avenue , Urbana , Illinois 61801 , United States
| | - Joaquín Rodríguez-López
- Department of Chemistry , University of Illinois at Urbana-Champaign , 600 South Mathews Avenue , Urbana , Illinois 61801 , United States.,Beckman Institute for Advanced Science and Technology , 405 North Mathews Avenue , Urbana , Illinois 61801 , United States
| |
Collapse
|
21
|
Huang L, Li Z, Lou Y, Cao F, Zhang D, Li X. Recent Advances in Scanning Electrochemical Microscopy for Biological Applications. MATERIALS (BASEL, SWITZERLAND) 2018; 11:E1389. [PMID: 30096895 PMCID: PMC6119995 DOI: 10.3390/ma11081389] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/25/2018] [Revised: 07/24/2018] [Accepted: 07/28/2018] [Indexed: 12/17/2022]
Abstract
Scanning electrochemical microscopy (SECM) is a chemical microscopy technique with high spatial resolution for imaging sample topography and mapping specific chemical species in liquid environments. With the development of smaller, more sensitive ultramicroelectrodes (UMEs) and more precise computer-controlled measurements, SECM has been widely used to study biological systems over the past three decades. Recent methodological breakthroughs have popularized SECM as a tool for investigating molecular-level chemical reactions. The most common applications include monitoring and analyzing the biological processes associated with enzymatic activity and DNA, and the physiological activity of living cells and other microorganisms. The present article first introduces the basic principles of SECM, followed by an updated review of the applications of SECM in biological studies on enzymes, DNA, proteins, and living cells. Particularly, the potential of SECM for investigating bacterial and biofilm activities is discussed.
Collapse
Affiliation(s)
- Luyao Huang
- Institute for Advanced Materials and Technology, University of Science and Technology Beijing, Beijing 100083, China.
| | - Ziyu Li
- Institute for Advanced Materials and Technology, University of Science and Technology Beijing, Beijing 100083, China.
| | - Yuntian Lou
- Institute for Advanced Materials and Technology, University of Science and Technology Beijing, Beijing 100083, China.
| | - Fahe Cao
- Department of Chemistry, Zhejiang University, Hangzhou 310027, China.
| | - Dawei Zhang
- Institute for Advanced Materials and Technology, University of Science and Technology Beijing, Beijing 100083, China.
| | - Xiaogang Li
- Institute for Advanced Materials and Technology, University of Science and Technology Beijing, Beijing 100083, China.
| |
Collapse
|
22
|
Shi W, Zeng Y, Zhou L, Xiao Y, Cummins TR, Baker LA. Membrane patches as ion channel probes for scanning ion conductance microscopy. Faraday Discuss 2018; 193:81-97. [PMID: 27711908 DOI: 10.1039/c6fd00133e] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
Abstract
We describe dual-barrel ion channel probes (ICPs), which consist of an open barrel and a barrel with a membrane patch directly excised from a donor cell. When incorporated with scanning ion conductance microscopy (SICM), the open barrel (SICM barrel) serves to measure the distance-dependent ion current for non-invasive imaging and positioning of the probe in the same fashion of traditional SICM. The second barrel with the membrane patch supports ion channels of interest and was used to investigate ion channel activities. To demonstrate robust probe control with the dual-barrel ICP-SICM probe and verify that the two barrels are independently addressable, current-distance characteristics (approach curves) were obtained with the SICM barrel and simultaneous, current-time (I-T) traces were recorded with the ICP barrel. To study the influence that the distance between ligand-gated ion channels (i.e., large conductance Ca2+-activated K+ channels/BK channels) and the ligand source (i.e., Ca2+ source) has on channel activations, ion channel activities were recorded at two fixed probe-substrate distances (Dps) with the ICP barrel. The two fixed positions were determined from approach curves acquired with the SICM barrel. One position was defined as the "In-control" position, where the probe was in close proximity to the ligand source; the second position was defined as the "Far" position, where the probe was retracted far away from the ligand source. Our results confirm that channel activities increased dramatically with respect to both open channel probability and single channel current when the probe was near the ligand source, as opposed to when the probe was far away from the ligand source.
Collapse
Affiliation(s)
- Wenqing Shi
- Department of Chemistry, Indiana University, 800 E. Kirkwood Avenue, Bloomington, Indiana 47405, USA.
| | - Yuhan Zeng
- Department of Chemistry, Indiana University, 800 E. Kirkwood Avenue, Bloomington, Indiana 47405, USA.
| | - Lushan Zhou
- Department of Chemistry, Indiana University, 800 E. Kirkwood Avenue, Bloomington, Indiana 47405, USA.
| | - Yucheng Xiao
- Department of Pharmacology and Toxicology, Indiana University-Purdue University Indianapolis, Stark Neurosciences Research Institute, 320 W. 15th St., Indianapolis, IN 46202, USA.
| | - Theodore R Cummins
- Department of Pharmacology and Toxicology, Indiana University-Purdue University Indianapolis, Stark Neurosciences Research Institute, 320 W. 15th St., Indianapolis, IN 46202, USA.
| | - Lane A Baker
- Department of Chemistry, Indiana University, 800 E. Kirkwood Avenue, Bloomington, Indiana 47405, USA.
| |
Collapse
|
23
|
A continuous control mode with improved imaging rate for scanning ion conductance microscope (SICM). Ultramicroscopy 2018; 190:66-76. [DOI: 10.1016/j.ultramic.2018.04.009] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2016] [Revised: 03/29/2018] [Accepted: 04/16/2018] [Indexed: 11/19/2022]
|
24
|
Patel AN, Kranz C. (Multi)functional Atomic Force Microscopy Imaging. ANNUAL REVIEW OF ANALYTICAL CHEMISTRY (PALO ALTO, CALIF.) 2018; 11:329-350. [PMID: 29490193 DOI: 10.1146/annurev-anchem-061417-125716] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
Incorporating functionality to atomic force microscopy (AFM) to obtain physical and chemical information has always been a strong focus in AFM research. Modifying AFM probes with specific molecules permits accessibility of chemical information via specific reactions and interactions. Fundamental understanding of molecular processes at the solid/liquid interface with high spatial resolution is essential to many emerging research areas. Nanoscale electrochemical imaging has emerged as a complementary technique to advanced AFM techniques, providing information on electrochemical interfacial processes. While this review presents a brief introduction to advanced AFM imaging modes, such as multiparametric AFM and topography recognition imaging, the main focus herein is on electrochemical imaging via hybrid AFM-scanning electrochemical microscopy. Recent applications and the challenges associated with such nanoelectrochemical imaging strategies are presented.
Collapse
Affiliation(s)
- Anisha N Patel
- Institute of Analytical and Bioanalytical Chemistry, Ulm University, Ulm 89081, Germany;
| | - Christine Kranz
- Institute of Analytical and Bioanalytical Chemistry, Ulm University, Ulm 89081, Germany;
| |
Collapse
|
25
|
Zhang S, Li M, Su B, Shao Y. Fabrication and Use of Nanopipettes in Chemical Analysis. ANNUAL REVIEW OF ANALYTICAL CHEMISTRY (PALO ALTO, CALIF.) 2018; 11:265-286. [PMID: 29894227 DOI: 10.1146/annurev-anchem-061417-125840] [Citation(s) in RCA: 31] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
This review summarizes progress in the fabrication, modification, characterization, and applications of nanopipettes since 2010. A brief history of nanopipettes is introduced, and the details of fabrication, modification, and characterization of nanopipettes are provided. Applications of nanopipettes in chemical analysis are the focus in several cases, including recent progress in imaging; in the study of single molecules, single nanoparticles, and single cells; in fundamental investigations of charge transfer (ion and electron) reactions at liquid/liquid interfaces; and as hyphenated techniques combined with other methods to study the mechanisms of complicated electrochemical reactions and to conduct bioanalysis.
Collapse
Affiliation(s)
- Shudong Zhang
- Beijing National Laboratory for Molecular Sciences, College of Chemistry and Molecular Engineering, Peking University, Beijing 100871, China;
| | - Mingzhi Li
- Beijing National Laboratory for Molecular Sciences, College of Chemistry and Molecular Engineering, Peking University, Beijing 100871, China;
| | - Bin Su
- Institute of Analytical Chemistry, Department of Chemistry, Zhejiang University, Hangzhou 310058, China;
| | - Yuanhua Shao
- Beijing National Laboratory for Molecular Sciences, College of Chemistry and Molecular Engineering, Peking University, Beijing 100871, China;
| |
Collapse
|
26
|
Advances and Perspectives in Chemical Imaging in Cellular Environments Using Electrochemical Methods. CHEMOSENSORS 2018. [DOI: 10.3390/chemosensors6020024] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
|
27
|
Mitsudo K, Kurimoto Y, Yoshioka K, Suga S. Miniaturization and Combinatorial Approach in Organic Electrochemistry. Chem Rev 2018; 118:5985-5999. [DOI: 10.1021/acs.chemrev.7b00532] [Citation(s) in RCA: 88] [Impact Index Per Article: 14.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/23/2023]
Affiliation(s)
- Koichi Mitsudo
- Division of Applied Chemistry, Graduate School of Natural Science and Technology, Okayama University, 3-1-1 Tsushima-naka, Kita-ku, Okayama 700-8530, Japan
| | - Yuji Kurimoto
- Division of Applied Chemistry, Graduate School of Natural Science and Technology, Okayama University, 3-1-1 Tsushima-naka, Kita-ku, Okayama 700-8530, Japan
| | - Kazuki Yoshioka
- Division of Applied Chemistry, Graduate School of Natural Science and Technology, Okayama University, 3-1-1 Tsushima-naka, Kita-ku, Okayama 700-8530, Japan
| | - Seiji Suga
- Division of Applied Chemistry, Graduate School of Natural Science and Technology, Okayama University, 3-1-1 Tsushima-naka, Kita-ku, Okayama 700-8530, Japan
| |
Collapse
|
28
|
Stephens LI, Mauzeroll J. Altered Spatial Resolution of Scanning Electrochemical Microscopy Induced by Multifunctional Dual-Barrel Microelectrodes. Anal Chem 2018; 90:6796-6803. [DOI: 10.1021/acs.analchem.8b00821] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Affiliation(s)
- Lisa I. Stephens
- Laboratory for Electrochemical Reactive
Imaging and Detection of Biological Systems, Department of Chemistry, McGill University, Montreal, Quebec H3A 0B8, Canada
| | - Janine Mauzeroll
- Laboratory for Electrochemical Reactive
Imaging and Detection of Biological Systems, Department of Chemistry, McGill University, Montreal, Quebec H3A 0B8, Canada
| |
Collapse
|
29
|
Takahashi Y, Ida H, Matsumae Y, Komaki H, Zhou Y, Kumatani A, Kanzaki M, Shiku H, Matsue T. 3D electrochemical and ion current imaging using scanning electrochemical-scanning ion conductance microscopy. Phys Chem Chem Phys 2018; 19:26728-26733. [PMID: 28951914 DOI: 10.1039/c7cp05157c] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Abstract
Local cell-membrane permeability and ionic strength are important factors for maintaining the functions of cells. Here, we measured the spatial electrochemical and ion concentration profile near the sample surface with nanoscale resolution using scanning electrochemical microscopy (SECM) combined with scanning ion-conductance microscopy (SICM). The ion current feedback system is an effective way to control probe-sample distance without contact and monitor the kinetic effect of mediator regeneration and the chemical concentration profile. For demonstrating 3D electrochemical and ion concentration mapping, we evaluated the reaction rate of electrochemical mediator regeneration on an unbiased conductor and visualized inhomogeneous permeability and the ion concentration 3D profile on a single fixed adipocyte cell surface.
Collapse
Affiliation(s)
- Yasufumi Takahashi
- WPI-Advanced Institute for Materials Research, Tohoku University, 980-8577, Japan.
| | | | | | | | | | | | | | | | | |
Collapse
|
30
|
Kai T, Zoski CG, Bard AJ. Scanning electrochemical microscopy at the nanometer level. Chem Commun (Camb) 2018; 54:1934-1947. [DOI: 10.1039/c7cc09777h] [Citation(s) in RCA: 81] [Impact Index Per Article: 13.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Chemical and electrochemical reactions at high temporal and spatial resolution can be studied using nanoscale SECM.
Collapse
Affiliation(s)
- Tianhan Kai
- Center for Electrochemistry
- Department of Chemistry
- The University of Texas at Austin
- Austin
- USA
| | - Cynthia G. Zoski
- Center for Electrochemistry
- Department of Chemistry
- The University of Texas at Austin
- Austin
- USA
| | - Allen J. Bard
- Center for Electrochemistry
- Department of Chemistry
- The University of Texas at Austin
- Austin
- USA
| |
Collapse
|
31
|
Izquierdo J, Knittel P, Kranz C. Scanning electrochemical microscopy: an analytical perspective. Anal Bioanal Chem 2017; 410:307-324. [PMID: 29214533 DOI: 10.1007/s00216-017-0742-7] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2017] [Revised: 10/16/2017] [Accepted: 11/02/2017] [Indexed: 10/18/2022]
Abstract
Scanning electrochemical microscopy (SECM) has evolved from an electrochemical specialist tool to a broadly used electroanalytical surface technique, which has experienced exciting developments for nanoscale electrochemical studies in recent years. Several companies now offer commercial instruments, and SECM has been used in a broad range of applications. SECM research is frequently interdisciplinary, bridging areas ranging from electrochemistry, nanotechnology, and materials science to biomedical research. Although SECM is considered a modern electroanalytical technique, it appears that less attention is paid to so-called analytical figures of merit, which are essential also in electroanalytical chemistry. Besides instrumental developments, this review focuses on aspects such as reliability, repeatability, and reproducibility of SECM data. The review is intended to spark discussion within the community on this topic, but also to raise awareness of the challenges faced during the evaluation of quantitative SECM data.
Collapse
Affiliation(s)
- Javier Izquierdo
- Institute of Analytical and Bioanalytical Chemistry, Ulm University, Albert-Einstein-Allee 11, 89081, Ulm, Germany
| | - Peter Knittel
- Institute of Analytical and Bioanalytical Chemistry, Ulm University, Albert-Einstein-Allee 11, 89081, Ulm, Germany
- Fraunhofer Institute for Applied Solid State Physics, Tullastraße 72, 79108, Freiburg, Germany
| | - Christine Kranz
- Institute of Analytical and Bioanalytical Chemistry, Ulm University, Albert-Einstein-Allee 11, 89081, Ulm, Germany.
| |
Collapse
|
32
|
In situ investigation of copper corrosion in acidic chloride solution using atomic force—scanning electrochemical microscopy. Electrochim Acta 2017. [DOI: 10.1016/j.electacta.2017.07.042] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
|
33
|
Tip current/positioning close-loop mode of scanning electrochemical microscopy for electrochemical micromachining. Electrochem commun 2017. [DOI: 10.1016/j.elecom.2017.07.023] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
|
34
|
Page A, Perry D, Unwin PR. Multifunctional scanning ion conductance microscopy. Proc Math Phys Eng Sci 2017; 473:20160889. [PMID: 28484332 PMCID: PMC5415692 DOI: 10.1098/rspa.2016.0889] [Citation(s) in RCA: 57] [Impact Index Per Article: 8.1] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2016] [Accepted: 03/13/2017] [Indexed: 12/21/2022] Open
Abstract
Scanning ion conductance microscopy (SICM) is a nanopipette-based technique that has traditionally been used to image topography or to deliver species to an interface, particularly in a biological setting. This article highlights the recent blossoming of SICM into a technique with a much greater diversity of applications and capability that can be used either standalone, with advanced control (potential-time) functions, or in tandem with other methods. SICM can be used to elucidate functional information about interfaces, such as surface charge density or electrochemical activity (ion fluxes). Using a multi-barrel probe format, SICM-related techniques can be employed to deposit nanoscale three-dimensional structures and further functionality is realized when SICM is combined with scanning electrochemical microscopy (SECM), with simultaneous measurements from a single probe opening up considerable prospects for multifunctional imaging. SICM studies are greatly enhanced by finite-element method modelling for quantitative treatment of issues such as resolution, surface charge and (tip) geometry effects. SICM is particularly applicable to the study of living systems, notably single cells, although applications extend to materials characterization and to new methods of printing and nanofabrication. A more thorough understanding of the electrochemical principles and properties of SICM provides a foundation for significant applications of SICM in electrochemistry and interfacial science.
Collapse
Affiliation(s)
- Ashley Page
- Department of Chemistry, University of Warwick, Coventry CV4 7AL, UK
- MOAC Doctoral Training Centre, University of Warwick, Coventry CV4 7AL, UK
| | - David Perry
- Department of Chemistry, University of Warwick, Coventry CV4 7AL, UK
- MOAC Doctoral Training Centre, University of Warwick, Coventry CV4 7AL, UK
| | - Patrick R. Unwin
- Department of Chemistry, University of Warwick, Coventry CV4 7AL, UK
| |
Collapse
|
35
|
Ying YL, Ding Z, Zhan D, Long YT. Advanced electroanalytical chemistry at nanoelectrodes. Chem Sci 2017; 8:3338-3348. [PMID: 28507703 PMCID: PMC5416909 DOI: 10.1039/c7sc00433h] [Citation(s) in RCA: 83] [Impact Index Per Article: 11.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2017] [Accepted: 02/16/2017] [Indexed: 01/10/2023] Open
Abstract
Nanoelectrodes, with dimensions below 100 nm, have the advantages of high sensitivity and high spatial resolution. These electrodes have attracted increasing attention in various fields such as single cell analysis, single-molecule detection, single particle characterization and high-resolution imaging. The rapid growth of novel nanoelectrodes and nanoelectrochemical methods brings enormous new opportunities in the field. In this perspective, we discuss the challenges, advances, and opportunities for nanoelectrode fabrication, real-time characterizations and high-performance electrochemical instrumentation.
Collapse
Affiliation(s)
- Yi-Lun Ying
- School of Chemistry & Molecular Engineering , East China University of Science and Technology , Shanghai , 200237 , P. R. China .
| | - Zhifeng Ding
- Department of Chemistry , University of Western Ontario , 1151 Richmond Street , London , ON N6A 5B7 , Canada
| | - Dongping Zhan
- State Key Laboratory of Physical Chemistry of Solid Surfaces , Collaborative Innovation Centre of Chemistry for Energy Materials (iChEM) , Department of Chemistry , College of Chemistry and Chemical Engineering , Xiamen University , Xiamen , 361005 , P. R. China
| | - Yi-Tao Long
- School of Chemistry & Molecular Engineering , East China University of Science and Technology , Shanghai , 200237 , P. R. China .
| |
Collapse
|
36
|
Page A, Kang M, Armitstead A, Perry D, Unwin PR. Quantitative Visualization of Molecular Delivery and Uptake at Living Cells with Self-Referencing Scanning Ion Conductance Microscopy-Scanning Electrochemical Microscopy. Anal Chem 2017; 89:3021-3028. [DOI: 10.1021/acs.analchem.6b04629] [Citation(s) in RCA: 57] [Impact Index Per Article: 8.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Affiliation(s)
- Ashley Page
- Department of Chemistry and ‡MOAC Doctoral
Training Centre, University of Warwick, Coventry, CV4 7AL, United Kingdom
| | - Minkyung Kang
- Department of Chemistry and ‡MOAC Doctoral
Training Centre, University of Warwick, Coventry, CV4 7AL, United Kingdom
| | - Alexander Armitstead
- Department of Chemistry and ‡MOAC Doctoral
Training Centre, University of Warwick, Coventry, CV4 7AL, United Kingdom
| | - David Perry
- Department of Chemistry and ‡MOAC Doctoral
Training Centre, University of Warwick, Coventry, CV4 7AL, United Kingdom
| | - Patrick R. Unwin
- Department of Chemistry and ‡MOAC Doctoral
Training Centre, University of Warwick, Coventry, CV4 7AL, United Kingdom
| |
Collapse
|
37
|
Saha-Shah A, Green CM, Abraham DH, Baker LA. Segmented flow sampling with push-pull theta pipettes. Analyst 2017; 141:1958-65. [PMID: 26907673 DOI: 10.1039/c6an00028b] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
Abstract
We report development of a mobile and easy-to-fabricate theta pipette microfluidic device for segmented flow sampling. The theta pipettes were also used as electrospray emitters for analysis of sub-nanoliter segments, which resulted in delivery of analyte to the vacuum inlet of the mass spectrometer without multiple transfer steps. Theta pipette probes enable sample collection with high spatial resolution due to micron or smaller sized probe inlets and can be used to manipulate aqueous segments in the range of 200 pL to tens of nanoliters. Optimized conditions can enable sampling with high spatial and temporal resolution, suitable for chemical monitoring in biological samples and studies of sample heterogeneity. Intercellular heterogeneity among Allium cepa cells was studied by collecting cytoplasm from multiple cells using a single probe. Extracted cytoplasm was analyzed in a fast and high throughput manner by direct electrospray mass spectrometry of segmented sample from the probe tip.
Collapse
Affiliation(s)
- Anumita Saha-Shah
- Department of Chemistry, Indiana University, 800 E. Kirkwood Avenue, Bloomington, IN 47405, USA.
| | - Curtis M Green
- Department of Chemistry, Indiana University, 800 E. Kirkwood Avenue, Bloomington, IN 47405, USA.
| | - David H Abraham
- Department of Chemistry, Indiana University, 800 E. Kirkwood Avenue, Bloomington, IN 47405, USA.
| | - Lane A Baker
- Department of Chemistry, Indiana University, 800 E. Kirkwood Avenue, Bloomington, IN 47405, USA.
| |
Collapse
|
38
|
Affiliation(s)
- Wenqing Shi
- Department of Chemistry, Indiana University, 800 E. Kirkwood Avenue, Bloomington, Indiana 47405, United States
| | - Alicia K. Friedman
- Department of Chemistry, Indiana University, 800 E. Kirkwood Avenue, Bloomington, Indiana 47405, United States
| | - Lane A. Baker
- Department of Chemistry, Indiana University, 800 E. Kirkwood Avenue, Bloomington, Indiana 47405, United States
| |
Collapse
|
39
|
Park HS, Jang JH. Applications of Scanning Electrochemical Microscopy (SECM) Coupled to Atomic Force Microscopy with Sub-Micrometer Spatial Resolution to the Development and Discovery of Electrocatalysts. J ELECTROCHEM SCI TE 2016. [DOI: 10.5229/jecst.2016.7.4.316] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
|
40
|
Park HS, Jang JH. Applications of Scanning Electrochemical Microscopy (SECM) Coupled to Atomic Force Microscopy with Sub-Micrometer Spatial Resolution to the Development and Discovery of Electrocatalysts. J ELECTROCHEM SCI TE 2016. [DOI: 10.33961/jecst.2016.7.4.316] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
41
|
Takahashi Y, Kumatani A, Shiku H, Matsue T. Scanning Probe Microscopy for Nanoscale Electrochemical Imaging. Anal Chem 2016; 89:342-357. [DOI: 10.1021/acs.analchem.6b04355] [Citation(s) in RCA: 78] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Affiliation(s)
- Yasufumi Takahashi
- Division
of Electrical Engineering and Computer Science, Kanazawa University, Kanazawa 920-1192, Japan
- Precursory
Research for Embryonic Science and Technology (PRESTO), Japan Science and Technology Agency (JST), Saitama 332-0012, Japan
| | - Akichika Kumatani
- Advanced
Institute for Materials Research, Tohoku University, Sendai 980-8577, Japan
- Graduate
School of Environmental Studies, Tohoku University, Sendai 980-8579, Japan
| | - Hitoshi Shiku
- Department
of Applied Chemistry, Graduate School of Engineering, Tohoku University, Sendai 980-8579, Japan
| | - Tomokazu Matsue
- Advanced
Institute for Materials Research, Tohoku University, Sendai 980-8577, Japan
- Graduate
School of Environmental Studies, Tohoku University, Sendai 980-8579, Japan
| |
Collapse
|
42
|
Polcari D, Dauphin-Ducharme P, Mauzeroll J. Scanning Electrochemical Microscopy: A Comprehensive Review of Experimental Parameters from 1989 to 2015. Chem Rev 2016; 116:13234-13278. [PMID: 27736057 DOI: 10.1021/acs.chemrev.6b00067] [Citation(s) in RCA: 195] [Impact Index Per Article: 24.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Affiliation(s)
- David Polcari
- Department
of Chemistry, McGill University, 801 Sherbrooke Street West, Montreal, Quebec Canada, H3A 0B8
| | - Philippe Dauphin-Ducharme
- Department
of Chemistry, McGill University, 801 Sherbrooke Street West, Montreal, Quebec Canada, H3A 0B8
| | - Janine Mauzeroll
- Department
of Chemistry, McGill University, 801 Sherbrooke Street West, Montreal, Quebec Canada, H3A 0B8
| |
Collapse
|
43
|
Kim J, Renault C, Nioradze N, Arroyo-Currás N, Leonard KC, Bard AJ. Nanometer Scale Scanning Electrochemical Microscopy Instrumentation. Anal Chem 2016; 88:10284-10289. [DOI: 10.1021/acs.analchem.6b03024] [Citation(s) in RCA: 38] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Affiliation(s)
- Jiyeon Kim
- Department of Chemistry, The University of Rhode Island, Kingston, Rhode Island 02881, United States
| | - Christophe Renault
- Laboratoire
de Physique de la Matière Condensée, Ecole Polytechnique Palaiseau, 91128 Palaiseau, France
| | - Nikoloz Nioradze
- The Institute of Inorganic Chemistry and Electrochemistry, Tbilisi State University, Tbilisi 0179, Georgia
| | - Netzahualcóyotl Arroyo-Currás
- Department of Chemistry and Biochemistry, University of California Santa Barbara, Santa Barbara, California 93111, United States
| | - Kevin C. Leonard
- Center for Environmentally Beneficial Catalysis, Department of Chemical
and Petroleum Engineering, The University of Kansas, Lawrence, Kansas 66047, United States
| | - Allen J. Bard
- Center for Electrochemistry, Department of Chemistry, The University of Texas at Austin, Austin, Texas 78712, United States
| |
Collapse
|
44
|
Kang M, Momotenko D, Page A, Perry D, Unwin PR. Frontiers in Nanoscale Electrochemical Imaging: Faster, Multifunctional, and Ultrasensitive. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2016; 32:7993-8008. [PMID: 27396415 DOI: 10.1021/acs.langmuir.6b01932] [Citation(s) in RCA: 50] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
A wide range of interfacial physicochemical processes, from electrochemistry to the functioning of living cells, involve spatially localized chemical fluxes that are associated with specific features of the interface. Scanning electrochemical probe microscopes (SEPMs) represent a powerful means of visualizing interfacial fluxes, and this Feature Article highlights recent developments that have radically advanced the speed, spatial resolution, functionality, and sensitivity of SEPMs. A major trend has been a coming together of SEPMs that developed independently and the use of established SEPMs in completely new ways, greatly expanding their scope and impact. The focus is on nanopipette-based SEPMs, including scanning ion conductance microscopy (SICM), scanning electrochemical cell microscopy (SECCM), and hybrid techniques thereof, particularly with scanning electrochemical microscopy (SECM). Nanopipette-based probes are made easily, quickly, and cheaply with tunable characteristics. They are reproducible and can be fully characterized. Their response can be modeled in considerable detail so that quantitative maps of chemical fluxes and other properties (e.g., local charge) can be obtained and analyzed. This article provides an overview of the use of these probes for high-speed imaging, to create movies of electrochemical processes in action, to carry out multifunctional mapping such as simultaneous topography-charge and topography-activity, and to create nanoscale electrochemical cells for the detection, trapping, and analysis of single entities, particularly individual molecules and nanoparticles (NPs). These studies provide a platform for the further application and diversification of SEPMs across a wide range of interfacial science.
Collapse
Affiliation(s)
- Minkyung Kang
- Department of Chemistry and ‡MOAC Doctoral Training Centre, University of Warwick , Coventry CV4 7AL, United Kingdom
| | - Dmitry Momotenko
- Department of Chemistry and ‡MOAC Doctoral Training Centre, University of Warwick , Coventry CV4 7AL, United Kingdom
| | - Ashley Page
- Department of Chemistry and ‡MOAC Doctoral Training Centre, University of Warwick , Coventry CV4 7AL, United Kingdom
| | - David Perry
- Department of Chemistry and ‡MOAC Doctoral Training Centre, University of Warwick , Coventry CV4 7AL, United Kingdom
| | - Patrick R Unwin
- Department of Chemistry and ‡MOAC Doctoral Training Centre, University of Warwick , Coventry CV4 7AL, United Kingdom
| |
Collapse
|
45
|
Fan Y, Han C, Zhang B. Recent advances in the development and application of nanoelectrodes. Analyst 2016; 141:5474-87. [PMID: 27510555 DOI: 10.1039/c6an01285j] [Citation(s) in RCA: 36] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
Nanoelectrodes have key advantages compared to electrodes of conventional size and are the tool of choice for numerous applications in both fundamental electrochemistry research and bioelectrochemical analysis. This Minireview summarizes recent advances in the development, characterization, and use of nanoelectrodes in nanoscale electroanalytical chemistry. Methods of nanoelectrode preparation include laser-pulled glass-sealed metal nanoelectrodes, mass-produced nanoelectrodes, carbon nanotube based and carbon-filled nanopipettes, and tunneling nanoelectrodes. Several new topics of their recent application are covered, which include the use of nanoelectrodes for electrochemical imaging at ultrahigh spatial resolution, imaging with nanoelectrodes and nanopipettes, electrochemical analysis of single cells, single enzymes, and single nanoparticles, and the use of nanoelectrodes to understand single nanobubbles.
Collapse
Affiliation(s)
- Yunshan Fan
- Department of Chemistry, University of Washington, Seattle, Washington 98115, USA.
| | | | | |
Collapse
|
46
|
|
47
|
Nanoelectrodes: Applications in electrocatalysis, single-cell analysis and high-resolution electrochemical imaging. Trends Analyt Chem 2016. [DOI: 10.1016/j.trac.2016.01.018] [Citation(s) in RCA: 126] [Impact Index Per Article: 15.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/23/2023]
|
48
|
Characterization of tip size and geometry of the pipettes used in scanning ion conductance microscopy. Micron 2016; 83:11-8. [DOI: 10.1016/j.micron.2016.01.002] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2015] [Revised: 01/05/2016] [Accepted: 01/12/2016] [Indexed: 11/20/2022]
|
49
|
O'Connell MA, Lewis JR, Wain AJ. Electrochemical imaging of hydrogen peroxide generation at individual gold nanoparticles. Chem Commun (Camb) 2016; 51:10314-7. [PMID: 26023911 DOI: 10.1039/c5cc01640a] [Citation(s) in RCA: 48] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Localised hydrogen peroxide generation at individual catalytic gold nanoparticles within ensemble electrodes is mapped for the first time using combined scanning electrochemical-scanning ion conductance microscopy (SECM-SICM).
Collapse
|
50
|
Momotenko D, McKelvey K, Kang M, Meloni GN, Unwin PR. Simultaneous Interfacial Reactivity and Topography Mapping with Scanning Ion Conductance Microscopy. Anal Chem 2016; 88:2838-46. [DOI: 10.1021/acs.analchem.5b04566] [Citation(s) in RCA: 55] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Affiliation(s)
- Dmitry Momotenko
- Department of Chemistry, University of Warwick, Coventry, CV4 7AL, United Kingdom
| | - Kim McKelvey
- Department of Chemistry, University of Warwick, Coventry, CV4 7AL, United Kingdom
| | - Minkyung Kang
- Department of Chemistry, University of Warwick, Coventry, CV4 7AL, United Kingdom
| | - Gabriel N. Meloni
- Department of Chemistry, University of Warwick, Coventry, CV4 7AL, United Kingdom
| | - Patrick R. Unwin
- Department of Chemistry, University of Warwick, Coventry, CV4 7AL, United Kingdom
| |
Collapse
|