1
|
Wang Y, Zhou S, Quan Y, Liu Y, Zhou B, Chen X, Ma Z, Zhou Y. Label-free spatiotemporal decoding of single-cell fate via acoustic driven 3D tomography. Mater Today Bio 2024; 28:101201. [PMID: 39221213 PMCID: PMC11364901 DOI: 10.1016/j.mtbio.2024.101201] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2024] [Revised: 08/08/2024] [Accepted: 08/11/2024] [Indexed: 09/04/2024] Open
Abstract
Label-free three-dimensional imaging plays a crucial role in unraveling the complexities of cellular functions and interactions in biomedical research. Conventional single-cell optical tomography techniques offer affordability and the convenience of bypassing laborious cell labelling protocols. However, these methods are encumbered by restricted illumination scanning ranges on abaxial plane, resulting in the loss of intricate cellular imaging details. The ability to fully control cellular rotation across all angles has emerged as an optimal solution for capturing comprehensive structural details of cells. Here, we introduce a label-free, cost-effective, and readily fabricated contactless acoustic-induced vibration system, specifically designed to enable multi-degree-of-freedom rotation of cells, ultimately attaining stable in-situ rotation. Furthermore, by integrating this system with advanced deep learning technologies, we perform 3D reconstruction and morphological analysis on diverse cell types, thus validating groups of high-precision cell identification. Notably, long-term observation of cells reveals distinct features associated with drug-induced apoptosis in both cancerous and normal cells populations. This methodology, based on deep learning-enabled cell 3D reconstruction, charts a novel trajectory for groups of real-time cellular visualization, offering promising advancements in the realms of drug screening and post-single-cell analysis, thereby addressing potential clinical requisites.
Collapse
Affiliation(s)
- Yuxin Wang
- Joint Key Laboratory of the Ministry of Education, Institute of Applied Physics and Materials Engineering, University of Macau, Avenida da Universidade, Taipa, Macau, 999078, China
| | - Shizheng Zhou
- Joint Key Laboratory of the Ministry of Education, Institute of Applied Physics and Materials Engineering, University of Macau, Avenida da Universidade, Taipa, Macau, 999078, China
| | - Yue Quan
- Joint Key Laboratory of the Ministry of Education, Institute of Applied Physics and Materials Engineering, University of Macau, Avenida da Universidade, Taipa, Macau, 999078, China
| | - Yu Liu
- Joint Key Laboratory of the Ministry of Education, Institute of Applied Physics and Materials Engineering, University of Macau, Avenida da Universidade, Taipa, Macau, 999078, China
| | - Bingpu Zhou
- Joint Key Laboratory of the Ministry of Education, Institute of Applied Physics and Materials Engineering, University of Macau, Avenida da Universidade, Taipa, Macau, 999078, China
| | - Xiuping Chen
- State Key Laboratory of Quality Research in Chinese Medicine, Institute of Chinese Medical Sciences, University of Macau, Avenida da Universidade, Taipa, Macau, 999078, China
| | - Zhichao Ma
- Institute of Medical Robotics, School of Biomedical Engineering, Shanghai Jiao Tong University, No.800 Dongchuan Road, Shanghai, 200240, China
| | - Yinning Zhou
- Joint Key Laboratory of the Ministry of Education, Institute of Applied Physics and Materials Engineering, University of Macau, Avenida da Universidade, Taipa, Macau, 999078, China
| |
Collapse
|
2
|
Tian Y, Chen J, Yan Z, Xie J, Jiang X, Li G, Huang G. Numerical modeling of ultrasound-triggered microneedle-mediated delivery of drug particles into bacterial biofilms. ULTRASONICS 2024; 141:107344. [PMID: 38772060 DOI: 10.1016/j.ultras.2024.107344] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/15/2024] [Revised: 04/18/2024] [Accepted: 05/10/2024] [Indexed: 05/23/2024]
Abstract
Ultrasonic microneedle patches, a class of ultrasound-driven transdermal drug delivery systems, are promising in addressing bacterial biofilms. This device has been proven to be more effective in treating Staphylococcus aureus biofilms than drug in free solution. However, there exists a notable gap in understanding how various excitation conditions and material parameters affect drug delivery efficiency. This study aims to fill this void by conducting an comprehensive multi-physics numerical analysis of ultrasonic microneedle patches, with the ultimate goal of enhancing drug delivery. First, we investigate the impact of various ultrasound frequencies on drug penetration depths. The findings reveal that local resonance can accelerate drug release within a shorter time window (first 1.5 h), whereas non-resonant frequencies enable more profound and prolonged diffusion. This information is crucial for medical professionals in selecting the most effective frequency for optimal drug administration. Furthermore, our investigation extends to the effects of applied voltage on temperature distribution, a critical aspect for ensuring medical safety during the application of these patches. Additionally, we examine how particles of different sizes respond to acoustic pressure and streaming fields, providing valuable insights for tailoring drug delivery strategies to specific therapeutic needs. Overall, our findings offer comprehensive guidelines for the effective use of ultrasonic microneedle patches, potentially shifting the paradigm in patient care and enhancing the overall quality of life.
Collapse
Affiliation(s)
- Yiran Tian
- Department of Mechanical and Aerospace Engineering, University of Missouri, Columbia, MO 65211, USA
| | - Jiaji Chen
- Department of Mechanical and Aerospace Engineering, University of Missouri, Columbia, MO 65211, USA
| | - Zheng Yan
- Department of Chemical and Biomedical Engineering, University of Missouri, Columbia, MO 65211, USA
| | - Jingwei Xie
- Department of Surgery-Transplant and Mary & Dick Holland Regenerative Medicine Program, University of Nebraska Medical Center, Omaha, NE 68198, USA
| | - Xiaoning Jiang
- Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, NC 27695, USA
| | - Guangfu Li
- Department of Molecular Microbiology and Immunology, University of Missouri, Columbia, MO 65212, USA
| | - Guoliang Huang
- Department of Mechanical and Aerospace Engineering, University of Missouri, Columbia, MO 65211, USA.
| |
Collapse
|
3
|
Wei W, Wang Z, Wang B, Pang W, Yang Q, Duan X. Concentration of Microparticles/Cells Based on an Ultra-Fast Centrifuge Virtual Tunnel Driven by a Novel Lamb Wave Resonator Array. BIOSENSORS 2024; 14:280. [PMID: 38920584 PMCID: PMC11202289 DOI: 10.3390/bios14060280] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/23/2024] [Revised: 05/17/2024] [Accepted: 05/25/2024] [Indexed: 06/27/2024]
Abstract
The µTAS/LOC, a highly integrated microsystem, consolidates multiple bioanalytical functions within a single chip, enhancing efficiency and precision in bioanalysis and biomedical operations. Microfluidic centrifugation, a key component of LOC devices, enables rapid capture and enrichment of tiny objects in samples, improving sensitivity and accuracy of detection and diagnosis. However, microfluidic systems face challenges due to viscosity dominance and difficulty in vortex formation. Acoustic-based centrifugation, particularly those using surface acoustic waves (SAWs), have shown promise in applications such as particle concentration, separation, and droplet mixing. However, challenges include accurate droplet placement, energy loss from off-axis positioning, and limited energy transfer from low-frequency SAW resonators, restricting centrifugal speed and sample volume. In this work, we introduce a novel ring array composed of eight Lamb wave resonators (LWRs), forming an Ultra-Fast Centrifuge Tunnel (UFCT) in a microfluidic system. The UFCT eliminates secondary vortices, concentrating energy in the main vortex and maximizing acoustic-to-streaming energy conversion. It enables ultra-fast centrifugation with a larger liquid capacity (50 μL), reduced power usage (50 mW) that is one order of magnitude smaller than existing devices, and greater linear speed (62 mm/s), surpassing the limitations of prior methods. We demonstrate successful high-fold enrichment of 2 μm and 10 μm particles and explore the UFCT's potential in tissue engineering by encapsulating cells in a hydrogel-based micro-organ with a ring structure, which is of great significance for building more complex manipulation platforms for particles and cells in a bio-compatible and contactless manner.
Collapse
Affiliation(s)
| | | | | | | | - Qingrui Yang
- State Key Laboratory of Precision Measuring Technology & Instruments, Tianjin University, Tianjin 300072, China; (W.W.); (Z.W.); (B.W.); (W.P.)
| | - Xuexin Duan
- State Key Laboratory of Precision Measuring Technology & Instruments, Tianjin University, Tianjin 300072, China; (W.W.); (Z.W.); (B.W.); (W.P.)
| |
Collapse
|
4
|
Mao Y, Li J, Li J, Su C, Long K, Li D, Ding Z, Guo S. Enhanced immune capture of extracellular vesicles with gelatin nanoparticles and acoustic mixing. Analyst 2024; 149:3195-3203. [PMID: 38651605 DOI: 10.1039/d4an00268g] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/25/2024]
Abstract
Extracellular vesicles (EVs) originating from cancer cells incorporate various critical biomolecules that can aid in early cancer diagnosis. However, the rapid analysis of these micro vesicles remains challenging due to their nano-scale size and overlapping dimensions, hindering sufficient capture in terms of quantity and purity. In this study, an acoustofluidic device was developed to enhance the yield of immune-captured EVs. The channel of the device was modified with degradable gelatin nanoparticles (∼220 nm) to increase the surface roughness, and subsequently treated with CD63 antibodies. The acoustic-induced streaming would prolong the rotation time of the EVs in the targeted continuous flow area, improving their aggregation towards the surrounding pillars and subsequent capture by the specific CD63 antibodies. Consequently, the capture efficiency of the device was improved when the signal was on, as evidenced by enhanced fluorescence intensity in the main channel. It is demonstrated that the acoustofluidic device could enhance the immune capture of EVs through acoustic mixing, showcasing great potential in the rapid and fast detection of EVs in liquid biopsy applications.
Collapse
Affiliation(s)
- Yiqian Mao
- Key Laboratory of Artificial Micro- and Nano-structures of Ministry of Education, School of Physics and Technology, Wuhan University, Wuhan 430072, P. R. China.
| | - Juan Li
- Key Laboratory of Artificial Micro- and Nano-structures of Ministry of Education, School of Physics and Technology, Wuhan University, Wuhan 430072, P. R. China.
- Hubei Yangtze Memory Laboratories, Wuhan 430205, P. R. China
| | - Jingxing Li
- Key Laboratory of Artificial Micro- and Nano-structures of Ministry of Education, School of Physics and Technology, Wuhan University, Wuhan 430072, P. R. China.
| | - Cuicui Su
- Key Laboratory of Artificial Micro- and Nano-structures of Ministry of Education, School of Physics and Technology, Wuhan University, Wuhan 430072, P. R. China.
| | - Kaixiang Long
- Key Laboratory of Artificial Micro- and Nano-structures of Ministry of Education, School of Physics and Technology, Wuhan University, Wuhan 430072, P. R. China.
| | - Daojiang Li
- Department of Colorectal and Anal Surgery, Hubei Key Laboratory of Intestinal and Colorectal Diseases, Zhongnan Hospital of Wuhan University, Wuhan 430071, P. R. China
| | - Zhao Ding
- Department of Colorectal and Anal Surgery, Hubei Key Laboratory of Intestinal and Colorectal Diseases, Zhongnan Hospital of Wuhan University, Wuhan 430071, P. R. China
| | - Shishang Guo
- Key Laboratory of Artificial Micro- and Nano-structures of Ministry of Education, School of Physics and Technology, Wuhan University, Wuhan 430072, P. R. China.
- Hubei Yangtze Memory Laboratories, Wuhan 430205, P. R. China
| |
Collapse
|
5
|
Wells TN, Schmidt H, Hawkins AR. Constrained Volume Micro- and Nanoparticle Collection Methods in Microfluidic Systems. MICROMACHINES 2024; 15:699. [PMID: 38930668 PMCID: PMC11206162 DOI: 10.3390/mi15060699] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/01/2024] [Revised: 05/23/2024] [Accepted: 05/23/2024] [Indexed: 06/28/2024]
Abstract
Particle trapping and enrichment into confined volumes can be useful in particle processing and analysis. This review is an evaluation of the methods used to trap and enrich particles into constrained volumes in microfluidic and nanofluidic systems. These methods include physical, optical, electrical, magnetic, acoustic, and some hybrid techniques, all capable of locally enhancing nano- and microparticle concentrations on a microscale. Some key qualitative and quantitative comparison points are also explored, illustrating the specific applicability and challenges of each method. A few applications of these types of particle trapping are also discussed, including enhancing biological and chemical sensors, particle washing techniques, and fluid medium exchange systems.
Collapse
Affiliation(s)
- Tanner N. Wells
- Department of Electrical and Computer Engineering, Brigham Young University, Provo, UT 84602, USA
| | - Holger Schmidt
- School of Engineering, University of California Santa Cruz, Santa Cruz, CA 95064, USA
| | - Aaron R. Hawkins
- Department of Electrical and Computer Engineering, Brigham Young University, Provo, UT 84602, USA
| |
Collapse
|
6
|
Lin L, Zhu R, Li W, Dong G, You H. The Shape Effect of Acoustic Micropillar Array Chips in Flexible Label-Free Separation of Cancer Cells. MICROMACHINES 2024; 15:421. [PMID: 38675233 PMCID: PMC11052022 DOI: 10.3390/mi15040421] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/25/2024] [Revised: 03/16/2024] [Accepted: 03/18/2024] [Indexed: 04/28/2024]
Abstract
The precise isolation of circulating tumor cells (CTCs) from blood samples is a potent tool for cancer diagnosis and clinical prognosis. However, CTCs are present in extremely low quantities in the bloodstream, posing a significant challenge to their isolation. In this study, we propose a non-contact acoustic micropillar array (AMPA) chip based on acoustic streaming for the flexible, label-free capture of cancer cells. Three shapes of micropillar array chips (circular, rhombus, and square) were fabricated. The acoustic streaming characteristics generated by the vibration of microstructures of different shapes are studied in depth by combining simulation and experiment. The critical parameters (voltage and flow rate) of the device were systematically investigated using microparticle experiments to optimize capture performance. Subsequently, the capture efficiencies of the three micropillar structures were experimentally evaluated using mouse whole blood samples containing cancer cells. The experimental results revealed that the rhombus microstructure was selected as the optimal shape, demonstrating high capture efficiency (93%) and cell activity (96%). Moreover, the reversibility of the acoustic streaming was harnessed for the flexible release and capture of cancer cells, facilitating optical detection and analysis. This work holds promise for applications in monitoring cancer metastasis, bio-detection, and beyond.
Collapse
Affiliation(s)
- Lin Lin
- Key Laboratory of Disaster Prevention and Structural Safety of Ministry of Education, Guangxi University, Nanning 530004, China; (R.Z.); (W.L.); (G.D.)
- School of Mechanical Engineering, Guangxi University, Nanning 530004, China
- Guangxi Key Lab of Manufacturing System and Advanced Manufacturing Technology, Nanning 530003, China
| | - Rongxing Zhu
- Key Laboratory of Disaster Prevention and Structural Safety of Ministry of Education, Guangxi University, Nanning 530004, China; (R.Z.); (W.L.); (G.D.)
- School of Mechanical Engineering, Guangxi University, Nanning 530004, China
- Guangxi Key Lab of Manufacturing System and Advanced Manufacturing Technology, Nanning 530003, China
| | - Wang Li
- Key Laboratory of Disaster Prevention and Structural Safety of Ministry of Education, Guangxi University, Nanning 530004, China; (R.Z.); (W.L.); (G.D.)
- School of Mechanical Engineering, Guangxi University, Nanning 530004, China
- Guangxi Key Lab of Manufacturing System and Advanced Manufacturing Technology, Nanning 530003, China
| | - Guoqiang Dong
- Key Laboratory of Disaster Prevention and Structural Safety of Ministry of Education, Guangxi University, Nanning 530004, China; (R.Z.); (W.L.); (G.D.)
- School of Mechanical Engineering, Guangxi University, Nanning 530004, China
- Guangxi Key Lab of Manufacturing System and Advanced Manufacturing Technology, Nanning 530003, China
| | - Hui You
- Key Laboratory of Disaster Prevention and Structural Safety of Ministry of Education, Guangxi University, Nanning 530004, China; (R.Z.); (W.L.); (G.D.)
- School of Mechanical Engineering, Guangxi University, Nanning 530004, China
- Guangxi Key Lab of Manufacturing System and Advanced Manufacturing Technology, Nanning 530003, China
| |
Collapse
|
7
|
Sato T, Kaneko K, Hayakawa T, Suzuki H. Pneumatic Microballoons for Active Control of the Vibration-Induced Flow. MICROMACHINES 2023; 14:2010. [PMID: 38004868 PMCID: PMC10673574 DOI: 10.3390/mi14112010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/03/2023] [Revised: 10/27/2023] [Accepted: 10/27/2023] [Indexed: 11/26/2023]
Abstract
Vibration-induced flow (VIF), in which a mean flow is induced around a microstructure by applying periodic vibrations, is increasingly used as an active flow-control technique at the microscale. In this study, we have developed a microdevice that actively controls the VIF patterns using elastic membrane protrusions (microballoons) actuated by pneumatic pressure. This device enables on-demand spatial and temporal fluid manipulation using a single device that cannot be achieved using a conventional fixed-structure arrangement. We successfully demonstrated that the device achieved displacements of up to 38 µm using the device within a pressure range of 0 to 30 kPa, indicating the suitability of the device for microfluidic applications. Using this active microballoon array, we demonstrated that the device can actively manipulate the flow field and induce swirling flows. Furthermore, we achieved selective actuation of the microballoon using this system. By applying air pressure from a multi-input channel system through a connection tube, the microballoons corresponding to each air channel can be selectively actuated. This enabled precise control of the flow field and periodic switching of the flow patterns using a single chip. In summary, the proposed microdevice provides active control of VIF patterns and has potential applications in advanced microfluidics, such as fluid mixing and particle manipulation.
Collapse
Affiliation(s)
| | | | | | - Hiroaki Suzuki
- Department of Precision Mechanics, Faculty of Science and Engineering, Chuo University, Tokyo 112-8551, Japan; (T.S.); (K.K.); (T.H.)
| |
Collapse
|
8
|
Liu Y, Yin Q, Luo Y, Huang Z, Cheng Q, Zhang W, Zhou B, Zhou Y, Ma Z. Manipulation with sound and vibration: A review on the micromanipulation system based on sub-MHz acoustic waves. ULTRASONICS SONOCHEMISTRY 2023; 96:106441. [PMID: 37216791 PMCID: PMC10213378 DOI: 10.1016/j.ultsonch.2023.106441] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/27/2023] [Revised: 05/06/2023] [Accepted: 05/12/2023] [Indexed: 05/24/2023]
Abstract
Manipulation of micro-objects have been playing an essential role in biochemical analysis or clinical diagnostics. Among the diverse technologies for micromanipulation, acoustic methods show the advantages of good biocompatibility, wide tunability, a label-free and contactless manner. Thus, acoustic micromanipulations have been widely exploited in micro-analysis systems. In this article, we reviewed the acoustic micromanipulation systems that were actuated by sub-MHz acoustic waves. In contrast to the high-frequency range, the acoustic microsystems operating at sub-MHz acoustic frequency are more accessible, whose acoustic sources are at low cost and even available from daily acoustic devices (e.g. buzzers, speakers, piezoelectric plates). The broad availability, with the addition of the advantages of acoustic micromanipulation, make sub-MHz microsystems promising for a variety of biomedical applications. Here, we review recent progresses in sub-MHz acoustic micromanipulation technologies, focusing on their applications in biomedical fields. These technologies are based on the basic acoustic phenomenon, such as cavitation, acoustic radiation force, and acoustic streaming. And categorized by their applications, we introduce these systems for mixing, pumping and droplet generation, separation and enrichment, patterning, rotation, propulsion and actuation. The diverse applications of these systems hold great promise for a wide range of enhancements in biomedicines and attract increasing interest for further investigation.
Collapse
Affiliation(s)
- Yu Liu
- Institute of Medical Robotics, School of Biomedical Engineering, Shanghai Jiao Tong University, No.800 Dongchuan Road, Shanghai 200240, China; Joint Key Laboratory of the Ministry of Education, Institute of Applied Physics and Materials Engineering, University of Macau, Taipa, Macau 999078, China
| | - Qiu Yin
- State Key Laboratory of Mechanical System and Vibration, Shanghai Jiao Tong University, Shanghai 200240, China
| | - Yucheng Luo
- Institute of Medical Robotics, School of Biomedical Engineering, Shanghai Jiao Tong University, No.800 Dongchuan Road, Shanghai 200240, China
| | - Ziyu Huang
- Joint Key Laboratory of the Ministry of Education, Institute of Applied Physics and Materials Engineering, University of Macau, Taipa, Macau 999078, China
| | - Quansheng Cheng
- Joint Key Laboratory of the Ministry of Education, Institute of Applied Physics and Materials Engineering, University of Macau, Taipa, Macau 999078, China
| | - Wenming Zhang
- State Key Laboratory of Mechanical System and Vibration, Shanghai Jiao Tong University, Shanghai 200240, China
| | - Bingpu Zhou
- Joint Key Laboratory of the Ministry of Education, Institute of Applied Physics and Materials Engineering, University of Macau, Taipa, Macau 999078, China
| | - Yinning Zhou
- Joint Key Laboratory of the Ministry of Education, Institute of Applied Physics and Materials Engineering, University of Macau, Taipa, Macau 999078, China.
| | - Zhichao Ma
- Institute of Medical Robotics, School of Biomedical Engineering, Shanghai Jiao Tong University, No.800 Dongchuan Road, Shanghai 200240, China.
| |
Collapse
|
9
|
Kolesnik K, Segeritz P, Scott DJ, Rajagopal V, Collins DJ. Sub-wavelength acoustic stencil for tailored micropatterning. LAB ON A CHIP 2023; 23:2447-2457. [PMID: 37042175 DOI: 10.1039/d3lc00043e] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/17/2023]
Abstract
Acoustofluidic devices are ideal for biomedical micromanipulation applications, with high biocompatibility and the ability to generate force gradients down to the scale of cells. However, complex and designed patterning at the microscale remains challenging. In this work we report an acoustofluidic approach to direct particles and cells within a structured surface in arbitrary configurations. Wells, trenches and cavities are embedded in this surface. Combined with a half-wavelength acoustic field, together these form an 'acoustic stencil' where arbitrary cell and particle arrangements can be reversibly generated. Here a bulk-wavemode lithium niobate resonator generates multiplexed parallel patterning via a multilayer resonant geometry, where cell-scale resolution is accomplished via structured sub-wavelength microfeatures. Uniquely, this permits simultaneous manipulation in a unidirectional, device-spanning single-node field across scalable ∼cm2 areas in a microfluidic device. This approach is demonstrated via patterning of 5, 10 and 15 μm particles and 293-F cells in a variety of arrangements, where these activities are enabling for a range of cell studies and tissue engineering applications via the generation of highly complex and designed acoustic patterns at the microscale.
Collapse
Affiliation(s)
- Kirill Kolesnik
- Department of Biomedical Engineering, The University of Melbourne, Parkville, VIC 3010, Victoria, Australia.
| | - Philipp Segeritz
- Department of Biomedical Engineering, The University of Melbourne, Parkville, VIC 3010, Victoria, Australia.
- The Florey Institute of Neuroscience and Mental Health, The University of Melbourne, 30 Royal Parade, Parkville, VIC 3052, Australia
| | - Daniel J Scott
- The Florey Institute of Neuroscience and Mental Health, The University of Melbourne, 30 Royal Parade, Parkville, VIC 3052, Australia
- Department of Biochemistry and Pharmacology, The University of Melbourne, Parkville, VIC 3010, Australia
| | - Vijay Rajagopal
- Department of Biomedical Engineering, The University of Melbourne, Parkville, VIC 3010, Victoria, Australia.
| | - David J Collins
- Department of Biomedical Engineering, The University of Melbourne, Parkville, VIC 3010, Victoria, Australia.
- The Graeme Clark Institute, The University of Melbourne, Parkville, VIC, 3010, Australia
| |
Collapse
|
10
|
Hu Q, Hu X, Shi Y, Liang L, Zhu J, Zhao S, Wang Y, Wu Z, Wang F, Zhou F, Yang Y. Heterogeneous tissue construction by on-demand bubble-assisted acoustic patterning. LAB ON A CHIP 2023; 23:2206-2216. [PMID: 37006165 DOI: 10.1039/d3lc00122a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
Highly heterogeneous structures are closely related to the realization of the tissue functions of living organisms. However, precisely controlling the assembly of heterogeneous structures is still a crucial challenge. This work presents an on-demand bubble-assisted acoustic method for active cell patterning to achieve high-precision heterogeneous structures. Active cell patterning is achieved by the combined effect of acoustic radiation forces and microstreaming around oscillating bubble arrays. On-demand bubble arrays allow flexible construction of cell patterns with a precision of up to 45 μm. As a typical example, the in vitro model of hepatic lobules, composed of patterned endothelial cells and hepatic parenchymal cells, was constructed and cultured for 5 days. The good performance of urea and albumin secretion, enzymatic activity and good proliferation of both cells prove the feasibility of this technique. Overall, this bubble-assisted acoustic approach provides a simple and efficient strategy for on-demand large-area tissue construction, with considerable potential for different tissue model fabrication.
Collapse
Affiliation(s)
- Qinghao Hu
- Department of Clinical Laboratory, Institute of Medicine and Physics, Renmin Hospital, Key Laboratory of Artificial Micro- and Nano-Structures of Ministry of Education, School of Physics & Technology, Wuhan University, Wuhan 430072, People's Republic of China.
- Shenzhen Research Institute, Wuhan University, Shenzhen 518000, People's Republic of China
| | - Xuejia Hu
- Department of Electronic Engineering, School of Electronic Science and Engineering, Xiamen University, Xiamen 361005, People's Republic of China
| | - Yang Shi
- Institute of Nanophotonics, Jinan University, Guangzhou 510632, China
| | - Li Liang
- Department of Clinical Laboratory, Institute of Medicine and Physics, Renmin Hospital, Key Laboratory of Artificial Micro- and Nano-Structures of Ministry of Education, School of Physics & Technology, Wuhan University, Wuhan 430072, People's Republic of China.
- Shenzhen Research Institute, Wuhan University, Shenzhen 518000, People's Republic of China
| | - Jiaomeng Zhu
- Department of Clinical Laboratory, Institute of Medicine and Physics, Renmin Hospital, Key Laboratory of Artificial Micro- and Nano-Structures of Ministry of Education, School of Physics & Technology, Wuhan University, Wuhan 430072, People's Republic of China.
- Shenzhen Research Institute, Wuhan University, Shenzhen 518000, People's Republic of China
| | - Shukun Zhao
- Department of Clinical Laboratory, Institute of Medicine and Physics, Renmin Hospital, Key Laboratory of Artificial Micro- and Nano-Structures of Ministry of Education, School of Physics & Technology, Wuhan University, Wuhan 430072, People's Republic of China.
- Shenzhen Research Institute, Wuhan University, Shenzhen 518000, People's Republic of China
| | - Yifan Wang
- Department of Clinical Laboratory, Institute of Medicine and Physics, Renmin Hospital, Key Laboratory of Artificial Micro- and Nano-Structures of Ministry of Education, School of Physics & Technology, Wuhan University, Wuhan 430072, People's Republic of China.
- Shenzhen Research Institute, Wuhan University, Shenzhen 518000, People's Republic of China
| | - Zezheng Wu
- Department of Clinical Laboratory, Institute of Medicine and Physics, Renmin Hospital, Key Laboratory of Artificial Micro- and Nano-Structures of Ministry of Education, School of Physics & Technology, Wuhan University, Wuhan 430072, People's Republic of China.
| | - Fubing Wang
- Department of Laboratory Medicine, Zhongnan Hospital, Wuhan University, Wuhan 430071, China
| | - Fuling Zhou
- Department of Hematology, Zhongnan Hospital, Wuhan University, Wuhan 430071, China
| | - Yi Yang
- Department of Clinical Laboratory, Institute of Medicine and Physics, Renmin Hospital, Key Laboratory of Artificial Micro- and Nano-Structures of Ministry of Education, School of Physics & Technology, Wuhan University, Wuhan 430072, People's Republic of China.
- Shenzhen Research Institute, Wuhan University, Shenzhen 518000, People's Republic of China
| |
Collapse
|
11
|
Lu Y, Tan W, Liu Z, Mu S, Zhu G. Degeneration of flow pattern in acousto-elastic flow through sharp-edge microchannels. ULTRASONICS SONOCHEMISTRY 2023; 95:106390. [PMID: 37003213 PMCID: PMC10457586 DOI: 10.1016/j.ultsonch.2023.106390] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/30/2022] [Revised: 03/01/2023] [Accepted: 03/26/2023] [Indexed: 06/19/2023]
Abstract
Acoustic streaming (AS) is the steady time-averaged flow generated by acoustic field, which has been widely used in enhancing mixing and particle manipulation. Current researches on acoustic streaming mainly focus on Newtonian fluids, while many biological and chemical solutions exhibit non-Newtonian properties. The acoustic streaming in viscoelastic fluids has been studied experimentally for the first time in this paper. We found that the addition of polyethylene oxide (PEO) polymer to the Newtonian fluid significantly altered the flow characteristics in the microchannel. The resulting acousto-elastic flow showed two modes: positive mode and negative mode. Specifically, the viscoelastic fluids under acousto-elastic flow exhibit mixing hysteresis features at low flow rates, and degeneration of flow pattern at high flow rates. Through quantitative analysis, the degeneration of flow pattern is further summarized as time fluctuation and spatial disturbance range reduction. The positive mode in acousto-elastic flow can be used for the mixing enhancement of viscoelastic fluids in the micromixer, while the negative mode provides a potential method for particle/cell manipulation in viscoelastic body fluids such as saliva by suppressing unstable flow.
Collapse
Affiliation(s)
- Yuwen Lu
- School of Chemical Engineering and Technology, Tianjin University, Tianjin 300354, China
| | - Wei Tan
- School of Chemical Engineering and Technology, Tianjin University, Tianjin 300354, China; Zhejiang Institute of Tianjin University, Ningbo, Zhejiang 315201, China
| | - Zhifang Liu
- School of Chemical Engineering and Technology, Tianjin University, Tianjin 300354, China
| | - Shuoshuo Mu
- School of Chemical Engineering and Technology, Tianjin University, Tianjin 300354, China
| | - Guorui Zhu
- School of Chemical Engineering and Technology, Tianjin University, Tianjin 300354, China; Zhejiang Institute of Tianjin University, Ningbo, Zhejiang 315201, China.
| |
Collapse
|
12
|
Wei W, Wang Y, Wang Z, Duan X. Microscale acoustic streaming for biomedical and bioanalytical applications. Trends Analyt Chem 2023. [DOI: 10.1016/j.trac.2023.116958] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
|
13
|
Lu Y, Tan W, Mu S, Zhu G. A multi-vortex micromixer based on the synergy of acoustics and inertia for nanoparticle synthesis. Anal Chim Acta 2023; 1239:340742. [PMID: 36628735 DOI: 10.1016/j.aca.2022.340742] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2022] [Accepted: 12/21/2022] [Indexed: 12/24/2022]
Abstract
Mixing is one of the most important steps in chemical reaction, sample preparation and emulsification. However, achieving complete mixing of fluids at high throughput is still a challenge for acoustic micromixers, which are limited by the intensity of the acoustic streaming. In this study, we proposed an acoustic-inertial micromixer based on multi-vortex synergy by introducing inertia into acoustic micromixer. The device contains side-wall sharp-edge structure and contraction-expansion array structure (SCEA) in the microchannel to enhance the acoustic streaming with inertial vortices. The mixing mechanism of SCEA was explored and the mixing process showed three modes: acoustic streaming dominant mode, acoustic-inertial synergy mode and inertial vortex dominant mode. On the basis of the "vortex seed" provided by the contraction-expansion structure, stronger chaotic advection was produced by the synergy of acoustic streaming and inertial vortices (including Dean vortex and horizontal vortex). Rapider mixing (0.20 m s) and wider operating ranges (0-3000 μL/min) were achieved in SCEA at lower driving voltages compared with conventional acoustic micromixers. Finally, more homogeneous and tunable chitosan nanoparticles and shellac nanoparticles were synthesized based on this device. The micromorphology, particle size distribution and drug loading properties of the products were measured and compared. This work provides a platform for control of mixing process in specific application environments with high operational flexibility, indicating potentially wider application of SCEA in multi-functional integration of lab-on-a-chip systems.
Collapse
Affiliation(s)
- Yuwen Lu
- School of Chemical Engineering and Technology, Tianjin University, Tianjin, 300354, China
| | - Wei Tan
- School of Chemical Engineering and Technology, Tianjin University, Tianjin, 300354, China; Zhejiang Institute of Tianjin University, Ningbo, Zhejiang, 315201, China
| | - Shuoshuo Mu
- School of Chemical Engineering and Technology, Tianjin University, Tianjin, 300354, China
| | - Guorui Zhu
- School of Chemical Engineering and Technology, Tianjin University, Tianjin, 300354, China; Zhejiang Institute of Tianjin University, Ningbo, Zhejiang, 315201, China.
| |
Collapse
|
14
|
Chen X, Zhang C, Liu B, Chang Y, Pang W, Duan X. A self-contained acoustofluidic platform for biomarker detection. LAB ON A CHIP 2022; 22:3817-3826. [PMID: 36069822 DOI: 10.1039/d2lc00541g] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Self-contained microfluidic platforms with on-chip integration of flow control units, microreactors, (bio)sensors, etc. are ideal systems for point-of-care (POC) testing. However, current approaches such as micropumps and microvalves, increase the cost and the control system, and it is rather difficult to integrate into a single chip. Herein, we demonstrated a versatile acoustofluidic platform actuated by a Lamb wave resonator (LWR) array, in which pumping, mixing, fluidic switching, and particle trapping are all achieved on a single chip. The high-speed microscale acoustic streaming triggered by the LWR in the confined microchannel can be utilized to realize a flow resistor and switch. Variable unidirectional pumping was realized by regulating the relative position of the LWR in various custom-designed microfluidic structures and adoption of different geometric parameters for the microchannel. In addition, to realize quantitative biomarker detection, the on-chip flow resistor, micropump, micromixer and particle trapper were also integrated with a CMOS photo sensor and electronic driver circuit, resulting in an automated handheld microfluidic system with no moving parts. Finally, the acoustofluidic platform was tested for prostate-specific antigen (PSA) sensing, which demonstrates the biocompatibility and applied potency of this proposed self-contained system in POC biomedical applications.
Collapse
Affiliation(s)
- Xian Chen
- State Key Laboratory of Precision Measuring Technology & Instruments, and College of Precision Instrument and Opto-electronics Engineering, Tianjin University, Tianjin 300072, China.
| | - Chuanchao Zhang
- State Key Laboratory of Precision Measuring Technology & Instruments, and College of Precision Instrument and Opto-electronics Engineering, Tianjin University, Tianjin 300072, China.
| | - Bohua Liu
- State Key Laboratory of Precision Measuring Technology & Instruments, and College of Precision Instrument and Opto-electronics Engineering, Tianjin University, Tianjin 300072, China.
| | - Ye Chang
- State Key Laboratory of Precision Measuring Technology & Instruments, and College of Precision Instrument and Opto-electronics Engineering, Tianjin University, Tianjin 300072, China.
| | - Wei Pang
- State Key Laboratory of Precision Measuring Technology & Instruments, and College of Precision Instrument and Opto-electronics Engineering, Tianjin University, Tianjin 300072, China.
| | - Xuexin Duan
- State Key Laboratory of Precision Measuring Technology & Instruments, and College of Precision Instrument and Opto-electronics Engineering, Tianjin University, Tianjin 300072, China.
| |
Collapse
|
15
|
You R, Wu H, Pang W, Duan X. On-Chip Arbitrary Manipulation of Single Particles by Acoustic Resonator Array. Anal Chem 2022; 94:5392-5398. [PMID: 35319870 DOI: 10.1021/acs.analchem.2c00130] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Effective and arbitrary manipulation of particles in liquid has attracted substantial interest. Acoustic tweezers, a new and promising tool, exhibit high biocompatibility, universality, and precision but lack arbitrariness. In this work, we report a gigahertz (GHz) bulk acoustic streaming tweezer (AST)-based micro-manipulation platform capable of efficiently translating acoustic energy to fluid kinetic energy, creating a controllable, quick-response, and stable flow field and precisely, arbitrarily, and universally manipulating a single particle to move like a microrobot. Through controlling the radio frequency signals applied on these resonators, the intensity and direction of the acoustic streaming flow can be quickly and arbitrarily adjusted. Consequently, the particle dispersed at the bottom can be arbitrarily and steadily driven along the predesigned route to the target position by the acoustic streaming drag force (ASF). We utilized four resonators cooperated as a work group to manipulate single SiO2 particles to complete nearly uniform linear motions and U-shaped motions, as well as playing billiards and exploring a maze, demonstrating the enormous potential of this GHz AST-based single-particle manipulation platform for separation, assembly, sensing, enriching, transporting, and so forth.
Collapse
Affiliation(s)
- Rui You
- State Key Laboratory of Precision Measuring Technology and Instrument, College of Precision Instrument and Opto-electronics Engineering, Tianjin University, Tianjin 300072, China
| | - Hang Wu
- State Key Laboratory of Precision Measuring Technology and Instrument, College of Precision Instrument and Opto-electronics Engineering, Tianjin University, Tianjin 300072, China
| | - Wei Pang
- State Key Laboratory of Precision Measuring Technology and Instrument, College of Precision Instrument and Opto-electronics Engineering, Tianjin University, Tianjin 300072, China
| | - Xuexin Duan
- State Key Laboratory of Precision Measuring Technology and Instrument, College of Precision Instrument and Opto-electronics Engineering, Tianjin University, Tianjin 300072, China
| |
Collapse
|
16
|
Athanassiadis AG, Ma Z, Moreno-Gomez N, Melde K, Choi E, Goyal R, Fischer P. Ultrasound-Responsive Systems as Components for Smart Materials. Chem Rev 2022; 122:5165-5208. [PMID: 34767350 PMCID: PMC8915171 DOI: 10.1021/acs.chemrev.1c00622] [Citation(s) in RCA: 75] [Impact Index Per Article: 37.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2021] [Indexed: 02/06/2023]
Abstract
Smart materials can respond to stimuli and adapt their responses based on external cues from their environments. Such behavior requires a way to transport energy efficiently and then convert it for use in applications such as actuation, sensing, or signaling. Ultrasound can carry energy safely and with low losses through complex and opaque media. It can be localized to small regions of space and couple to systems over a wide range of time scales. However, the same characteristics that allow ultrasound to propagate efficiently through materials make it difficult to convert acoustic energy into other useful forms. Recent work across diverse fields has begun to address this challenge, demonstrating ultrasonic effects that provide control over physical and chemical systems with surprisingly high specificity. Here, we review recent progress in ultrasound-matter interactions, focusing on effects that can be incorporated as components in smart materials. These techniques build on fundamental phenomena such as cavitation, microstreaming, scattering, and acoustic radiation forces to enable capabilities such as actuation, sensing, payload delivery, and the initiation of chemical or biological processes. The diversity of emerging techniques holds great promise for a wide range of smart capabilities supported by ultrasound and poses interesting questions for further investigations.
Collapse
Affiliation(s)
- Athanasios G. Athanassiadis
- Micro,
Nano, and Molecular Systems Group, Max Planck
Institute for Intelligent Systems, Heisenbergstrasse 3, 70569 Stuttgart, Germany
| | - Zhichao Ma
- Micro,
Nano, and Molecular Systems Group, Max Planck
Institute for Intelligent Systems, Heisenbergstrasse 3, 70569 Stuttgart, Germany
| | - Nicolas Moreno-Gomez
- Micro,
Nano, and Molecular Systems Group, Max Planck
Institute for Intelligent Systems, Heisenbergstrasse 3, 70569 Stuttgart, Germany
- Institute
of Physical Chemistry, University of Stuttgart, Pfaffenwaldring 55, 70569 Stuttgart, Germany
| | - Kai Melde
- Micro,
Nano, and Molecular Systems Group, Max Planck
Institute for Intelligent Systems, Heisenbergstrasse 3, 70569 Stuttgart, Germany
| | - Eunjin Choi
- Micro,
Nano, and Molecular Systems Group, Max Planck
Institute for Intelligent Systems, Heisenbergstrasse 3, 70569 Stuttgart, Germany
- Institute
of Physical Chemistry, University of Stuttgart, Pfaffenwaldring 55, 70569 Stuttgart, Germany
| | - Rahul Goyal
- Micro,
Nano, and Molecular Systems Group, Max Planck
Institute for Intelligent Systems, Heisenbergstrasse 3, 70569 Stuttgart, Germany
| | - Peer Fischer
- Micro,
Nano, and Molecular Systems Group, Max Planck
Institute for Intelligent Systems, Heisenbergstrasse 3, 70569 Stuttgart, Germany
- Institute
of Physical Chemistry, University of Stuttgart, Pfaffenwaldring 55, 70569 Stuttgart, Germany
| |
Collapse
|
17
|
Peng T, Li L, Zhou M, Jiang F. Concentration of Microparticles Using Flexural Acoustic Wave in Sessile Droplets. SENSORS (BASEL, SWITZERLAND) 2022; 22:1269. [PMID: 35162014 PMCID: PMC8839499 DOI: 10.3390/s22031269] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/05/2022] [Revised: 01/31/2022] [Accepted: 02/02/2022] [Indexed: 12/12/2022]
Abstract
Acoustic manipulation of microparticles and cells has attracted growing interest in biomedical applications. In particular, the use of acoustic waves to concentrate particles plays an important role in enhancing the detection process by biosensors. Here, we demonstrated microparticle concentration within sessile droplets placed on the hydrophobic surface using the flexural wave. The design benefits from streaming flow induced by the Lamb wave propagated in the glass waveguide to manipulate particles in the droplets. Microparticles will be concentrated at the central area of the droplet adhesion plane based on the balance among the streaming drag force, gravity, and buoyancy at the operating frequency. We experimentally demonstrated the concentration of particles of various sizes and tumor cells. Using numerical simulation, we predicted the acoustic pressure and streaming flow pattern within the droplet and characterized the underlying physical mechanisms for particle motion. The design is more suitable for micron-sized particle preparation, and it can be valuable for various biological, chemical, and medical applications.
Collapse
Affiliation(s)
- Tao Peng
- State Key Laboratory of High-Performance Complex Manufacturing, College of Mechanical and Electrical Engineering, Central South University, Changsha 410083, China; (T.P.); (L.L.); (M.Z.)
| | - Luming Li
- State Key Laboratory of High-Performance Complex Manufacturing, College of Mechanical and Electrical Engineering, Central South University, Changsha 410083, China; (T.P.); (L.L.); (M.Z.)
| | - Mingyong Zhou
- State Key Laboratory of High-Performance Complex Manufacturing, College of Mechanical and Electrical Engineering, Central South University, Changsha 410083, China; (T.P.); (L.L.); (M.Z.)
| | - Fengze Jiang
- Institute of Polymer Technology (LKT), Friedrich-Alexander-University Erlangen-Nurnberg, Am Weichselgarten 9, 91058 Erlangen, Germany
| |
Collapse
|
18
|
Immuno-Acoustic Sorting of Disease-Specific Extracellular Vesicles by Acoustophoretic Force. MICROMACHINES 2021; 12:mi12121534. [PMID: 34945384 PMCID: PMC8709371 DOI: 10.3390/mi12121534] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/17/2021] [Revised: 12/04/2021] [Accepted: 12/06/2021] [Indexed: 11/17/2022]
Abstract
Methods for the isolation and analysis of extracellular vesicles (EVs) have been extensively explored in the field of life science and in clinical diagnosis in recent years. The separation and efficient recovery of high-purity target EVs from biological samples are important prerequisites in the study of EVs. So far, commonly used methods of EV separation include ultracentrifugation, filtration, solvent precipitation and immunoaffinity capturing. However, these methods suffer from long processing time, EV damage and low enrichment efficiency. The use of acoustophoretic force facilitates the non-contact label-free manipulation of cells based on their size and compressibility but lacks specificity. Additionally, the acoustophoretic force exerted on sub-micron substances is normally weak and insufficient for separation. Here we present a novel immuno-acoustic sorting technology, where biological substances such as EVs, viruses, and biomolecules, can be specifically captured by antibody/receptor coated microparticles through immunoaffinity, and manipulated by an acoustophoretic force exerted on the microparticles. Using immuno-acoustic sorting technology, we successfully separated and purified HER2-positive EVs for further downstream analysis. This method holds great potential in isolating and purifying specific targets such as disease-related EVs from biological fluids and opens new possibilities for the EV-based early diagnosis and prognosis of diseases.
Collapse
|
19
|
Zhang W, Song B, Bai X, Jia L, Song L, Guo J, Feng L. Versatile acoustic manipulation of micro-objects using mode-switchable oscillating bubbles: transportation, trapping, rotation, and revolution. LAB ON A CHIP 2021; 21:4760-4771. [PMID: 34632476 DOI: 10.1039/d1lc00628b] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Controllable on-chip multimodal manipulation of micro-objects in microfluidic devices is urgently required for enhancing the efficiency of potential biomedical applications. However, fixed design and driving models make it difficult to achieve switchable multifunction efficiently in a single device. In this study, a versatile bubble-based acoustofluidic device is proposed for multimodal manipulation of micro-objects in a biocompatible manner. Identical bubbles trapped over the bottom microcavities are made to flexibly switch between four different oscillatory motions by varying the applied frequency to generate corresponding modes of streaming patterns in the microchannel. Such regular modes enable stable transportation, trapping, 3D rotation, and circular revolution of the micro-objects, which were experimentally and numerically verified. The mode-switchable manipulations can be noninvasively applied to particles, cells, and organisms with different sizes, shapes, and quantities and can be controlled by key driving parameters. Moreover, 3D cell reconstruction is developed by applying the out-of-plane rotational mode and analyzed for illustration of cell surface morphology while quantifying reliably basic cell properties. Finally, a simple platform is established to integrate user-friendly function control and reconstruction analysis. The mode-switchable acoustofluidic device features a versatile, controllable, and contactless micro-object manipulation method, which provides an efficient solution for biomedical applications.
Collapse
Affiliation(s)
- Wei Zhang
- School of Mechanical Engineering & Automation, Beihang University, Beijing 100191, China.
| | - Bin Song
- School of Mechanical Engineering & Automation, Beihang University, Beijing 100191, China.
| | - Xue Bai
- School of Mechanical Engineering & Automation, Beihang University, Beijing 100191, China.
| | - Lina Jia
- School of Mechanical Engineering & Automation, Beihang University, Beijing 100191, China.
| | - Li Song
- School of Mechanical Engineering & Automation, Beihang University, Beijing 100191, China.
| | - Jingli Guo
- School of Mechanical Engineering & Automation, Beihang University, Beijing 100191, China.
| | - Lin Feng
- School of Mechanical Engineering & Automation, Beihang University, Beijing 100191, China.
- Beijing Advanced Innovation Center for Biomedical Engineering, Beihang University, Beijing 100083, China
| |
Collapse
|
20
|
Doinikov AA, Fankhauser J, Dual J. Nonlinear dynamics of a solid particle in an acoustically excited viscoelastic fluid. I. Acoustic streaming. Phys Rev E 2021; 104:065107. [PMID: 35030836 DOI: 10.1103/physreve.104.065107] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2021] [Accepted: 11/30/2021] [Indexed: 12/24/2022]
Abstract
An analytical theory is developed for acoustic streaming induced by an axisymmetric acoustic wave field around an isotropic solid spherical particle in a compressible viscoelastic fluid. The particle is assumed to undergo pulsation, translation, and shape deformations of all orders. The fluid motion is described by the compressible Oldroyd-B model. No restrictions are imposed on the particle size with respect to the acoustic wavelength and the viscous penetration depth. The obtained analytical solutions are used in numerical simulations. It is shown that in the general case, the streaming velocity magnitude decreases with increasing polymer viscosity. Increasing relaxation time (elasticity) of the polymer solution leads to increasing streaming velocity magnitude as long as the relaxation time remains relatively small. It is also observed that the variation of the polymer viscosity and the relaxation time can change the pattern of streamlines.
Collapse
Affiliation(s)
- Alexander A Doinikov
- Department of Mechanical and Process Engineering, Institute for Mechanical Systems (IMES), Swiss Federal Institute of Technology (ETH Zurich), Tannenstrasse 3, 8092 Zurich, Switzerland
| | - Jonas Fankhauser
- Department of Mechanical and Process Engineering, Institute for Mechanical Systems (IMES), Swiss Federal Institute of Technology (ETH Zurich), Tannenstrasse 3, 8092 Zurich, Switzerland
| | - Jürg Dual
- Department of Mechanical and Process Engineering, Institute for Mechanical Systems (IMES), Swiss Federal Institute of Technology (ETH Zurich), Tannenstrasse 3, 8092 Zurich, Switzerland
| |
Collapse
|
21
|
Zhao SK, Hu XJ, Zhu JM, Luo ZY, Liang L, Yang DY, Chen YL, Chen LF, Zheng YJ, Hu QH, Zheng JJ, Guo SS, Cheng YX, Zhou FL, Yang Y. On-chip rapid drug screening of leukemia cells by acoustic streaming. LAB ON A CHIP 2021; 21:4005-4015. [PMID: 34476431 DOI: 10.1039/d1lc00684c] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Rapid and personalized single-cell drug screening testing plays an essential role in acute myeloid leukemia drug combination chemotherapy. Conventional chemotherapeutic drug screening is a time-consuming process because of the natural resistance of cell membranes to drugs, and there are still great challenges related to using technologies that change membrane permeability such as sonoporation in high-throughput and precise single-cell drug screening with minimal damage. In this study, we proposed an acoustic streaming-based non-invasive single-cell drug screening acceleration method, using high-frequency acoustic waves (>10 MHz) in a concentration gradient microfluidic device. High-frequency acoustics leads to increased difficulties in inducing cavitation and generates acoustic streaming around each single cell. Therefore, single-cell membrane permeability is non-invasively increased by the acoustic pressure and acoustic streaming-induced shear force, which significantly improves the drug uptake process. In the experiment, single human myeloid leukemia mononuclear (THP-1) cells were trapped by triangle cell traps in concentration gradient chips with different cytarabine (Ara-C) drug concentrations. Due to this dual acoustic effect, the drugs affect cell viability in less than 30 min, which is faster than traditional methods (usually more than 24 h). This dual acoustic effect-based drug delivery strategy has the potential to save time and reduce the cost of drug screening, when combined with microfluidic technology for multi-concentration drug screening. This strategy offers enormous potential for use in multiple drug screening or efficient drug combination screening in individualized/personalized treatments, which can greatly improve efficiency and reduce costs.
Collapse
Affiliation(s)
- Shu-Kun Zhao
- School of Physics & Technology, Key Laboratory of Artificial Micro/Nano Structure of Ministry of Education, Wuhan University, Wuhan 430072, China.
- Shenzhen Research Institute, Wuhan University, Shenzhen 518000, China
| | - Xue-Jia Hu
- School of Physics & Technology, Key Laboratory of Artificial Micro/Nano Structure of Ministry of Education, Wuhan University, Wuhan 430072, China.
- Shenzhen Research Institute, Wuhan University, Shenzhen 518000, China
| | - Jiao-Meng Zhu
- School of Physics & Technology, Key Laboratory of Artificial Micro/Nano Structure of Ministry of Education, Wuhan University, Wuhan 430072, China.
- Shenzhen Research Institute, Wuhan University, Shenzhen 518000, China
| | - Zi-Yi Luo
- Department of Laboratory Medicine, Zhongnan Hospital of Wuhan University, Wuhan University, Wuhan, 430072, China
| | - Li Liang
- College of Physics and Electronic Technology, Anhui Normal University, Wuhu, Hefei 241000, China
| | - Dong-Yong Yang
- Department of Obstetrics and Gynecology, Renmin Hospital of Wuhan University, Wuhan University, Wuhan, Hubei 430072, China
| | - Yan-Ling Chen
- Department of Laboratory Medicine, Zhongnan Hospital of Wuhan University, Wuhan University, Wuhan, 430072, China
| | - Long-Fei Chen
- School of Physics & Technology, Key Laboratory of Artificial Micro/Nano Structure of Ministry of Education, Wuhan University, Wuhan 430072, China.
- Shenzhen Research Institute, Wuhan University, Shenzhen 518000, China
| | - Ya-Jing Zheng
- Department of Obstetrics and Gynecology, Renmin Hospital of Wuhan University, Wuhan University, Wuhan, Hubei 430072, China
| | - Qing-Hao Hu
- School of Physics & Technology, Key Laboratory of Artificial Micro/Nano Structure of Ministry of Education, Wuhan University, Wuhan 430072, China.
- Shenzhen Research Institute, Wuhan University, Shenzhen 518000, China
| | - Jing-Jing Zheng
- School of Physics & Technology, Key Laboratory of Artificial Micro/Nano Structure of Ministry of Education, Wuhan University, Wuhan 430072, China.
- Shenzhen Research Institute, Wuhan University, Shenzhen 518000, China
| | - Shi-Shang Guo
- School of Physics & Technology, Key Laboratory of Artificial Micro/Nano Structure of Ministry of Education, Wuhan University, Wuhan 430072, China.
| | - Yan-Xiang Cheng
- Department of Obstetrics and Gynecology, Renmin Hospital of Wuhan University, Wuhan University, Wuhan, Hubei 430072, China
| | - Fu-Ling Zhou
- Department of Laboratory Medicine, Zhongnan Hospital of Wuhan University, Wuhan University, Wuhan, 430072, China
| | - Yi Yang
- School of Physics & Technology, Key Laboratory of Artificial Micro/Nano Structure of Ministry of Education, Wuhan University, Wuhan 430072, China.
- Shenzhen Research Institute, Wuhan University, Shenzhen 518000, China
| |
Collapse
|
22
|
Peng T, Fan C, Zhou M, Jiang F, Drummer D, Jiang B. Rapid Enrichment of Submicron Particles within a Spinning Droplet Driven by a Unidirectional Acoustic Transducer. Anal Chem 2021; 93:13293-13301. [PMID: 34554739 DOI: 10.1021/acs.analchem.1c02914] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
Efficient and rapid particle enrichment at the submicron scale is essential for research in biomedicine and biochemistry. Here, we demonstrate an acoustofluidic method for submicron particle enrichment within a spinning droplet driven by a unidirectional transducer. The unidirectional transducer generates intense sound energy with relatively low attenuation. Droplets placed offset in the wave propagation path on a polydimethylsiloxane film undergo strong pressure gradients, deforming into an ellipsoid shape and spinning at high speed. Benefitting from the drag force induced by the droplet spin and acoustic streaming and the radial force induced by the droplet compression and expansion, the submicron particles in the liquid droplet quickly enrich toward the central area following a spiral trajectory. Through numerical calculations and experimental processes, we have demonstrated the possible mechanism responsible for particle enrichment. The application of biological sample processing has also been exploited. This study anticipates that the strategy based on the spinning droplet and particle enrichment method will be highly desirable for many applications.
Collapse
Affiliation(s)
- Tao Peng
- State Key Laboratory of High Performance Complex Manufacturing, College of Mechanical and Electrical Engineering, Central South University, Changsha 410083, China
| | - Cui Fan
- State Key Laboratory of High Performance Complex Manufacturing, College of Mechanical and Electrical Engineering, Central South University, Changsha 410083, China
| | - Mingyong Zhou
- State Key Laboratory of High Performance Complex Manufacturing, College of Mechanical and Electrical Engineering, Central South University, Changsha 410083, China
| | - Fengze Jiang
- Institute of Polymer Technology (LKT), Friedrich-Alexander-University Erlangen-Nurnberg, Am Weichselgarten 9, Erlangen-Tennenlohe 91058, Germany
| | - Dietmar Drummer
- Institute of Polymer Technology (LKT), Friedrich-Alexander-University Erlangen-Nurnberg, Am Weichselgarten 9, Erlangen-Tennenlohe 91058, Germany
| | - Bingyan Jiang
- State Key Laboratory of High Performance Complex Manufacturing, College of Mechanical and Electrical Engineering, Central South University, Changsha 410083, China
| |
Collapse
|
23
|
Zhu J, Chen T, Chen C, Ding W. Valley Vortex Assisted and Topological Protected Microparticles Manipulation with Complicated 2D Patterns in a Star-like Sonic Crystal. MATERIALS (BASEL, SWITZERLAND) 2021; 14:4939. [PMID: 34501036 PMCID: PMC8433743 DOI: 10.3390/ma14174939] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/09/2021] [Revised: 08/26/2021] [Accepted: 08/27/2021] [Indexed: 01/16/2023]
Abstract
Arranging microparticles into desired patterns, especially in a complicated pattern with a reliable and tunable manner, is challenging but highly desirable in the fields such as biomedicine and tissue engineering. To overcome these limitations, here, by using the concept of topology in acoustics, the valley vortex is utilized to manipulate particles on a large scale with complicated 2D patterns in the star-like sonic crystals at different frequencies. A topologically protected edge state is obtained at the interface of the crystals with different valley Hall phases, which shows the ability of reliable microparticles control along the sharp corner and the capability of robust particles cluster aggregation in a defective system. The results may provide intriguing resources for future microfluidic systems in a complicated and brittle environment.
Collapse
Affiliation(s)
- Jian Zhu
- School of Mechanical Engineering, Xi’an Jiaotong University, Xi’an 710049, China; (T.C.); (C.C.); (W.D.)
| | | | | | | |
Collapse
|
24
|
Kolesnik K, Xu M, Lee PVS, Rajagopal V, Collins DJ. Unconventional acoustic approaches for localized and designed micromanipulation. LAB ON A CHIP 2021; 21:2837-2856. [PMID: 34268539 DOI: 10.1039/d1lc00378j] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
Acoustic fields are ideal for micromanipulation, being biocompatible and with force gradients approaching the scale of single cells. They have accordingly found use in a variety of microfluidic devices, including for microscale patterning, separation, and mixing. The bulk of work in acoustofluidics has been predicated on the formation of standing waves that form periodic nodal positions along which suspended particles and cells are aligned. An evolving range of applications, however, requires more targeted micromanipulation to create unique patterns and effects. To this end, recent work has made important advances in improving the flexibility with which acoustic fields can be applied, impressively demonstrating generating arbitrary arrangements of pressure fields, spatially localizing acoustic fields and selectively translating individual particles in ways that are not achievable via traditional approaches. In this critical review we categorize and examine these advances, each of which open the door to a wide range of applications in which single-cell fidelity and flexible micromanipulation are advantageous, including for tissue engineering, diagnostic devices, high-throughput sorting and microfabrication.
Collapse
Affiliation(s)
- Kirill Kolesnik
- Department of Biomedical Engineering, University of Melbourne, Melbourne, Victoria, Australia.
| | - Mingxin Xu
- Department of Biomedical Engineering, University of Melbourne, Melbourne, Victoria, Australia.
| | - Peter V S Lee
- Department of Biomedical Engineering, University of Melbourne, Melbourne, Victoria, Australia.
| | - Vijay Rajagopal
- Department of Biomedical Engineering, University of Melbourne, Melbourne, Victoria, Australia.
| | - David J Collins
- Department of Biomedical Engineering, University of Melbourne, Melbourne, Victoria, Australia.
| |
Collapse
|
25
|
Bai X, Song B, Chen Z, Zhang W, Chen D, Dai Y, Liang S, Zhang D, Zhao Z, Feng L. Postoperative evaluation of tumours based on label-free acoustic separation of circulating tumour cells by microstreaming. LAB ON A CHIP 2021; 21:2721-2729. [PMID: 34165474 DOI: 10.1039/d1lc00165e] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Metastatic tumour recurrence caused by circulating tumour cells (CTCs) after surgery is responsible for more than 90% of tumour-related deaths. A postoperative evaluation system based on the long-term dynamic detection of CTCs helps in guiding the postoperative treatment of tumours in real time and preventing metastases and recurrence of tumours after treatment. In this study, a simple, rapid, and low-cost postoperative evaluation system was established based on the number of CTCs captured by a label-free acoustic separation device from whole blood samples of mice, of which breast tumours were surgically removed, and tumour metastasis was successfully predicted. First, an acoustofluidic device with a custom-designed bottom microcavity array was fabricated to induce highly localised acoustic microstreaming by applying acoustic vibration. Second, experiments of capturing 'defined' cells (artificially mixed individual 4T1 cancer cells into normal blood) based on optimal acoustic streaming were performed. The separation device exhibited a high capture efficiency (>96%). Further applications of capturing the 'true' CTCs derived from postoperative mice were successfully developed to predict tumour prognosis based on the number of captured CTCs. Finally, the prediction was verified through long-term observation of mice with excised tumours. The acoustofluidic device can efficiently capture CTCs and precisely predict tumour metastasis in a low-cost and non-invasive manner. This will help clinicians monitor patients that underwent surgical resection of tumours over a long period of time and facilitate optimal treatment strategies in a timely manner.
Collapse
Affiliation(s)
- Xue Bai
- School of Mechanical Engineering & Automation, Beihang University, Xueyuan Road No. 37, Haidian District, Beijing 100191, China.
| | - Bin Song
- School of Mechanical Engineering & Automation, Beihang University, Xueyuan Road No. 37, Haidian District, Beijing 100191, China.
| | - Ziteng Chen
- CAS Key Laboratory for Biomedical Effects of Nanomaterials and Nanosafety, Institute of High Energy Physics, Chinese Academy of Sciences (CAS), Beijing 100049, China
| | - Wei Zhang
- School of Mechanical Engineering & Automation, Beihang University, Xueyuan Road No. 37, Haidian District, Beijing 100191, China.
| | - Dixiao Chen
- School of Mechanical Engineering & Automation, Beihang University, Xueyuan Road No. 37, Haidian District, Beijing 100191, China.
| | - Yuguo Dai
- School of Mechanical Engineering & Automation, Beihang University, Xueyuan Road No. 37, Haidian District, Beijing 100191, China.
| | - Shuzhang Liang
- School of Mechanical Engineering & Automation, Beihang University, Xueyuan Road No. 37, Haidian District, Beijing 100191, China.
| | - Deyuan Zhang
- School of Mechanical Engineering & Automation, Beihang University, Xueyuan Road No. 37, Haidian District, Beijing 100191, China. and Beijing Advanced Innovation Center for Biomedical Engineering, Beihang University, Beijing 100083, China
| | - Zhijun Zhao
- Clinical Laboratory Center, General Hospital of Ningxia Medical University, Yinchuan 750001, China and Ningxia Key Laboratory of Clinical and Pathogenic Microbiology, General Hospital of Ningxia Medical University, Yinchuan 750001, China
| | - Lin Feng
- School of Mechanical Engineering & Automation, Beihang University, Xueyuan Road No. 37, Haidian District, Beijing 100191, China. and CAS Key Laboratory for Biomedical Effects of Nanomaterials and Nanosafety, Institute of High Energy Physics, Chinese Academy of Sciences (CAS), Beijing 100049, China
| |
Collapse
|
26
|
Fan LL, Tian ZZ, Zhe J, Zhao L. Efficient microfluidic enrichment of nano-/submicroparticle in viscoelastic fluid. Electrophoresis 2021; 42:2273-2280. [PMID: 33629394 DOI: 10.1002/elps.202000330] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2020] [Revised: 01/31/2021] [Accepted: 02/17/2021] [Indexed: 11/12/2022]
Abstract
The enrichment and focusing of the nano-/submicroparticle (e.g., 150-1000 nm microvesicle shed from the plasma membrane) in the viscoelastic fluid has great potentials in the biomedical and clinical applications such as the disease diagnosis and the prognostic test for liquid biopsy. However, due to the small size and the resulting weak hydrodynamic force, the efficient manipulation of the nano-/submicroparticle by the passive viscoelastic microfluidic technology remains a major challenge. For instance, a typically long channel length is often required to achieve the focusing or the separation of the nano-/submicroparticle, which makes it difficult to be integrated in small chip area. In this work, a microchannel with gradually contracted cross-section and high aspect ratio (the ratio of the height to the average width of channel) is utilized to enhance the hydrodynamic force and change the force direction, eventually leading to the efficient enrichment of nano-/submicroparticles (500 and 860 nm) in a short channel length (2 cm). The influence of the flow rate, the particle size, the solid concentration, and the channel geometry on the enrichment of the nano-/submicroparticles are investigated. With simple structure, small footprint, easy operation, and good performance, the present device would be a promising platform for various lab-chip microvesicle-related biomedical research and disease diagnosis.
Collapse
Affiliation(s)
- Liang-Liang Fan
- School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an, Shaanxi, P. R. China.,School of Food Equipment Engineering and Science (FEES), Xi'an Jiaotong University, Xi'an, P. R. China
| | - Zhuang-Zhuang Tian
- School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an, Shaanxi, P. R. China
| | - Jiang Zhe
- Department of Mechanical Engineering, University of Akron, Akron, OH, USA
| | - Liang Zhao
- State Key Laboratory of Multiphase Flow in Power Engineering, Xi'an Jiaotong University, Xi'an, P. R. China
| |
Collapse
|
27
|
Chen X, Ren Y, Jiang T, Hou L, Jiang H. Characterization of Particle Movement and High-Resolution Separation of Microalgal Cells via Induced-Charge Electroosmotic Advective Spiral Flow. Anal Chem 2020; 93:1667-1676. [PMID: 33381971 DOI: 10.1021/acs.analchem.0c04251] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
Microalgae are renewable, sustainable, and economical sources of biofuels and are capable of addressing pressing global demand for energy security. However, two challenging issues to produce high-level biofuels are to separate promising algal strains and protect biofuels from contamination of undesired bacteria, which rely on an economical and high-resolution separation technology. Separation technology based on induced-charge electroosmotic (ICEO) vortices offers excellent promise in economical microalga separation for producing biofuels because of its reconfigurable and flexible profiles and sensitive and precise selectivity. In this work, a practical ICEO vortex device is developed to facilitate high-resolution isolation of rich-lipid microalgae for the first time. We investigate electrokinetic equilibrium states of particles and particle-fluid ICEO effect in binary-particle manipulation. Nanoparticle separation is performed to demonstrate the feasibility and resolution of this device, yielding clear separation. Afterward, we leverage this technology in isolation of Chlorella vulgaris from heterogeneous microalgae with the purity exceeding 96.4%. Besides, this platform is successfully engineered for the extraction of single-cell Oocystis sp., obtaining the purity surpassing 95.2%. Moreover, with modulating parameters, we isolate desired-cell-number Oocystis sp. enabling us to investigate proliferation mode and carry out transcriptome analyses of Oocystis sp. for high-quality neutral lipids. This platform can be extended directly to economically separate other biological micro/nanosamples to address pressing issues, involving energy security, environmental monitoring, and disease diagnosis.
Collapse
Affiliation(s)
- Xiaoming Chen
- School of Mechatronics Engineering, Harbin Institute of Technology, Harbin 150001, PR China
| | - Yukun Ren
- School of Mechatronics Engineering, Harbin Institute of Technology, Harbin 150001, PR China.,State Key Laboratory of Robotics and System, Harbin Institute of Technology, Harbin 150001, PR China
| | - Tianyi Jiang
- School of Mechatronics Engineering, Harbin Institute of Technology, Harbin 150001, PR China
| | - Likai Hou
- School of Mechatronics Engineering, Harbin Institute of Technology, Harbin 150001, PR China
| | - Hongyuan Jiang
- School of Mechatronics Engineering, Harbin Institute of Technology, Harbin 150001, PR China
| |
Collapse
|