1
|
Fischer MS, Rogers HT, Chapman EA, Chan HJ, Krichel B, Gao Z, Larson EJ, Ge Y. Online Mixed-Bed Ion Exchange Chromatography for Native Top-Down Proteomics of Complex Mixtures. J Proteome Res 2024; 23:2315-2322. [PMID: 38913967 PMCID: PMC11344481 DOI: 10.1021/acs.jproteome.4c00430] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/26/2024]
Abstract
Native top-down mass spectrometry (nTDMS) allows characterization of protein structure and noncovalent interactions with simultaneous sequence mapping and proteoform characterization. The majority of nTDMS studies utilize purified recombinant proteins, with significant challenges hindering application to endogenous systems. To perform native top-down proteomics (nTDP), where endogenous proteins from complex biological systems are analyzed by nTDMS, it is essential to separate proteins under nondenaturing conditions. However, it remains difficult to achieve high resolution with MS-compatible online chromatography while preserving protein tertiary structure and noncovalent interactions. Herein, we report the use of online mixed-bed ion exchange chromatography (IEC) to enable separation of endogenous proteins from complex mixtures under nondenaturing conditions, preserving noncovalent interactions for nTDP analysis. We have successfully detected large proteins (>146 kDa) and identified endogenous metal-binding and oligomeric protein complexes in human heart tissue lysate. The use of a mixed-bed stationary phase allowed retention and elution of proteins over a wide range of isoelectric points without altering the sample or mobile phase pH. Overall, our method provides a simple online IEC-MS platform that can effectively separate proteins from complex mixtures under nondenaturing conditions and preserve higher-order structure for nTDP applications.
Collapse
Affiliation(s)
- Matthew S. Fischer
- Department of Chemistry, University of Wisconsin - Madison, 1101 University Ave, Madison, WI, USA 53706
| | - Holden T. Rogers
- Department of Chemistry, University of Wisconsin - Madison, 1101 University Ave, Madison, WI, USA 53706
| | - Emily A. Chapman
- Department of Chemistry, University of Wisconsin - Madison, 1101 University Ave, Madison, WI, USA 53706
| | - Hsin-Ju Chan
- Department of Chemistry, University of Wisconsin - Madison, 1101 University Ave, Madison, WI, USA 53706
| | - Boris Krichel
- Department of Cell and Regenerative Biology, University of Wisconsin - Madison, 1111 Highland Ave., Madison, WI, USA 53705
- School of Life Sciences, University of Siegen, Adolf-Reichwein Str. 2a, Siegen, Germany, 57076
| | - Zhan Gao
- Department of Cell and Regenerative Biology, University of Wisconsin - Madison, 1111 Highland Ave., Madison, WI, USA 53705
| | - Eli J. Larson
- Department of Chemistry, University of Wisconsin - Madison, 1101 University Ave, Madison, WI, USA 53706
| | - Ying Ge
- Department of Chemistry, University of Wisconsin - Madison, 1101 University Ave, Madison, WI, USA 53706
- Department of Cell and Regenerative Biology, University of Wisconsin - Madison, 1111 Highland Ave., Madison, WI, USA 53705
- Human Proteomics Program, School of Medicine and Public Health, University of Wisconsin - 1111 Highland Ave., Madison, WI, USA 53705
| |
Collapse
|
2
|
Zhai Z, Mavridou D, Damian M, Mutti FG, Schoenmakers PJ, Gargano AFG. Characterization of Complex Proteoform Mixtures by Online Nanoflow Ion-Exchange Chromatography-Native Mass Spectrometry. Anal Chem 2024; 96:8880-8885. [PMID: 38771719 PMCID: PMC11154664 DOI: 10.1021/acs.analchem.4c01760] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2024] [Revised: 05/16/2024] [Accepted: 05/20/2024] [Indexed: 05/23/2024]
Abstract
The characterization of proteins and complexes in biological systems is essential to establish their critical properties and to understand their unique functions in a plethora of bioprocesses. However, it is highly difficult to analyze low levels of intact proteins in their native states (especially those exceeding 30 kDa) with liquid chromatography (LC)-mass spectrometry (MS). Herein, we describe for the first time the use of nanoflow ion-exchange chromatography directly coupled with native MS to resolve mixtures of intact proteins. Reference proteins and protein complexes with molecular weights between 10 and 150 kDa and a model cell lysate were separated using a salt-mediated pH gradient method with volatile additives. The method allowed for low detection limits (0.22 pmol of monoclonal antibodies), while proteins presented nondenatured MS (low number of charges and limited charge state distributions), and the oligomeric state of the complexes analyzed was mostly kept. Excellent chromatographic separations including the resolution of different proteoforms of large proteins (>140 kDa) and a peak capacity of 82 in a 30 min gradient were obtained. The proposed setup and workflows show great potential for analyzing diverse proteoforms in native top-down proteomics, opening unprecedented opportunities for clinical studies and other sample-limited applications.
Collapse
Affiliation(s)
- Ziran Zhai
- Analytical
Chemistry Group and Biocatalysis Group, Van’t Hoff Institute
for Molecular Sciences (HIMS), University
of Amsterdam, Science Park 904, 1098 XH Amsterdam, The Netherlands
- Centre
for Analytical Sciences Amsterdam, Van’t Hoff Institute for
Molecular Sciences (HIMS), University of
Amsterdam, Science Park
904, 1098 XH Amsterdam, The Netherlands
| | - Despoina Mavridou
- Analytical
Chemistry Group and Biocatalysis Group, Van’t Hoff Institute
for Molecular Sciences (HIMS), University
of Amsterdam, Science Park 904, 1098 XH Amsterdam, The Netherlands
- Centre
for Analytical Sciences Amsterdam, Van’t Hoff Institute for
Molecular Sciences (HIMS), University of
Amsterdam, Science Park
904, 1098 XH Amsterdam, The Netherlands
| | - Matteo Damian
- Analytical
Chemistry Group and Biocatalysis Group, Van’t Hoff Institute
for Molecular Sciences (HIMS), University
of Amsterdam, Science Park 904, 1098 XH Amsterdam, The Netherlands
| | - Francesco G. Mutti
- Analytical
Chemistry Group and Biocatalysis Group, Van’t Hoff Institute
for Molecular Sciences (HIMS), University
of Amsterdam, Science Park 904, 1098 XH Amsterdam, The Netherlands
| | - Peter J. Schoenmakers
- Analytical
Chemistry Group and Biocatalysis Group, Van’t Hoff Institute
for Molecular Sciences (HIMS), University
of Amsterdam, Science Park 904, 1098 XH Amsterdam, The Netherlands
- Centre
for Analytical Sciences Amsterdam, Van’t Hoff Institute for
Molecular Sciences (HIMS), University of
Amsterdam, Science Park
904, 1098 XH Amsterdam, The Netherlands
| | - Andrea F. G. Gargano
- Analytical
Chemistry Group and Biocatalysis Group, Van’t Hoff Institute
for Molecular Sciences (HIMS), University
of Amsterdam, Science Park 904, 1098 XH Amsterdam, The Netherlands
- Centre
for Analytical Sciences Amsterdam, Van’t Hoff Institute for
Molecular Sciences (HIMS), University of
Amsterdam, Science Park
904, 1098 XH Amsterdam, The Netherlands
| |
Collapse
|
3
|
Guo X, Wang P, Yuwen W, Zhu C, Fu R, Ma P, Duan Z, Fan D. Production and Functional Analysis of Collagen Hexapeptide Repeat Sequences in Pichia pastoris. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY 2024. [PMID: 38801678 DOI: 10.1021/acs.jafc.4c00582] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2024]
Abstract
In the development of biomaterials with specific structural domains associated with various cellular activities, the limited integrin specificity of commonly used adhesion sequences, such as the RGD tripeptide, has resulted in an inability to precisely control cellular responses. To overcome this limitation, we conducted multiple replications of the integrin α2β1-specific ligand, the collagen hexapeptide Gly-Phe-Pro-Gly-Glu-Arg (GFPGER) in Pichia pastoris. This enabled the development of recombinant collagen with high biological activity, which was subsequently expressed, isolated, and purified for structural and functional analysis. The proteins carrying the multiple replications GFPGER sequence demonstrated significant bioactivity in cells, leading to enhanced cell adhesion, osteoblast differentiation, and mineralization when compared to control groups. Importantly, these effects were mediated by integrin α2β1. The new collagen constructed in this study is expected to be a biomaterial for regulating specific cell functions and fates.
Collapse
Affiliation(s)
- Xiaoyan Guo
- Engineering Research Center of Western Resource Innovation Medicine Green Manufacturing, Ministry of Education, School of Chemical Engineering, Northwest University, Xi'an 710069, China
- Shaanxi R&D Center of Biomaterials and Fermentation Engineering, School of Chemical Engineering, Northwest University, Xi'an 710069, China
- Biotech. & Biomed. Research Institute, Northwest University, Xi'an 710069, China
| | - Pan Wang
- Engineering Research Center of Western Resource Innovation Medicine Green Manufacturing, Ministry of Education, School of Chemical Engineering, Northwest University, Xi'an 710069, China
- Shaanxi R&D Center of Biomaterials and Fermentation Engineering, School of Chemical Engineering, Northwest University, Xi'an 710069, China
- Biotech. & Biomed. Research Institute, Northwest University, Xi'an 710069, China
| | - Weigang Yuwen
- Shaanxi Gaint Biotechnology Co., Ltd, Xi'an 710065, Shaanxi, China
| | - Chenhui Zhu
- Engineering Research Center of Western Resource Innovation Medicine Green Manufacturing, Ministry of Education, School of Chemical Engineering, Northwest University, Xi'an 710069, China
- Shaanxi R&D Center of Biomaterials and Fermentation Engineering, School of Chemical Engineering, Northwest University, Xi'an 710069, China
- Biotech. & Biomed. Research Institute, Northwest University, Xi'an 710069, China
| | - Rongzhan Fu
- Engineering Research Center of Western Resource Innovation Medicine Green Manufacturing, Ministry of Education, School of Chemical Engineering, Northwest University, Xi'an 710069, China
- Shaanxi R&D Center of Biomaterials and Fermentation Engineering, School of Chemical Engineering, Northwest University, Xi'an 710069, China
- Biotech. & Biomed. Research Institute, Northwest University, Xi'an 710069, China
| | - Pei Ma
- Engineering Research Center of Western Resource Innovation Medicine Green Manufacturing, Ministry of Education, School of Chemical Engineering, Northwest University, Xi'an 710069, China
- Shaanxi R&D Center of Biomaterials and Fermentation Engineering, School of Chemical Engineering, Northwest University, Xi'an 710069, China
- Biotech. & Biomed. Research Institute, Northwest University, Xi'an 710069, China
| | - Zhiguang Duan
- Engineering Research Center of Western Resource Innovation Medicine Green Manufacturing, Ministry of Education, School of Chemical Engineering, Northwest University, Xi'an 710069, China
- Shaanxi R&D Center of Biomaterials and Fermentation Engineering, School of Chemical Engineering, Northwest University, Xi'an 710069, China
- Biotech. & Biomed. Research Institute, Northwest University, Xi'an 710069, China
| | - Daidi Fan
- Engineering Research Center of Western Resource Innovation Medicine Green Manufacturing, Ministry of Education, School of Chemical Engineering, Northwest University, Xi'an 710069, China
- Shaanxi R&D Center of Biomaterials and Fermentation Engineering, School of Chemical Engineering, Northwest University, Xi'an 710069, China
- Biotech. & Biomed. Research Institute, Northwest University, Xi'an 710069, China
| |
Collapse
|
4
|
Steegmüller T, Kratky T, Gollwitzer L, Schwaminger SP, Berensmeier S. Development of a New Affinity Gold Polymer Membrane with Immobilized Protein A. MEMBRANES 2024; 14:31. [PMID: 38392658 PMCID: PMC10890041 DOI: 10.3390/membranes14020031] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/21/2023] [Revised: 01/08/2024] [Accepted: 01/19/2024] [Indexed: 02/24/2024]
Abstract
New and highly selective stationary phases for affinity membrane chromatography have the potential to significantly enhance the efficiency and specificity of therapeutic protein purification by reduced mass transfer limitations. This work developed and compared different immobilization strategies for recombinant Protein A ligands to a gold-sputtered polymer membrane for antibody separation in terms of functionalization and immobilization success, protein load, and stability. Successful, functionalization was validated via X-ray photoelectron spectroscopy (XPS). Here, a recombinant Protein A ligand was coupled by N-hydroxysuccinimide (NHS)/N-(3-dimethylaminopropyl)-N'-ethylcarbodiimide (EDC) chemistry to carboxy-functionalized, gold-sputtered membranes. We achieved a binding capacity of up to 104 ± 17 mg of the protein ligand per gram of the gold-sputtered membrane. The developed membranes were able to successfully capture and release the monoclonal antibody (mAb) Trastuzumab, as well as antibodies from fresh frozen human blood plasma in both static and dynamic setups. Therefore, they demonstrated successful functionalization and immobilization strategies. The antibody load was tested using bicinchoninic acid (BCA), ultraviolet-visible spectroscopy (UV-vis) measurements, and sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE). The outcome is a fully functional affinity membrane that can be implemented in a variety of different antibody purification processes, eliminating the need for creating individualized strategies for modifying the surface to suit different substrates or conditions.
Collapse
Affiliation(s)
- Tobias Steegmüller
- Chair of Bioseparation Engineering, TUM School of Engineering and Design, Technical University of Munich, Boltzmannstraße 15, 85748 Garching, Germany
| | - Tim Kratky
- Associate Professorship Physical Chemistry with Focus on Catalysis, TUM School of Natural Sciences, Technical University of Munich, Lichtenbergstraße 4, 85748 Garching, Germany
| | - Lena Gollwitzer
- Chair of Bioseparation Engineering, TUM School of Engineering and Design, Technical University of Munich, Boltzmannstraße 15, 85748 Garching, Germany
| | - Sebastian Patrick Schwaminger
- Chair of Bioseparation Engineering, TUM School of Engineering and Design, Technical University of Munich, Boltzmannstraße 15, 85748 Garching, Germany
- Division of Medicinal Chemistry, Otto-Loewi Research Center, Medical University of Graz, Neue Stiftingtalstraße 6, 8010 Graz, Austria
- BioTechMed-Graz, Mozartgasse 12, 8010 Graz, Austria
| | - Sonja Berensmeier
- Chair of Bioseparation Engineering, TUM School of Engineering and Design, Technical University of Munich, Boltzmannstraße 15, 85748 Garching, Germany
- Munich Institute of Integrated Materials, Energy and Process Engineering, Technical University of Munich, Lichtenbergstraße 4a, 85748 Garching, Germany
| |
Collapse
|
5
|
Duivelshof BL, Bouvarel T, Pirner S, Larraillet V, Knaupp A, Koll H, D’Atri V, Guillarme D. Enhancing Selectivity of Protein Biopharmaceuticals in Ion Exchange Chromatography through Addition of Organic Modifiers. Int J Mol Sci 2023; 24:16623. [PMID: 38068945 PMCID: PMC10706461 DOI: 10.3390/ijms242316623] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2023] [Revised: 11/15/2023] [Accepted: 11/20/2023] [Indexed: 12/18/2023] Open
Abstract
Charge heterogeneity among therapeutic monoclonal antibodies (mAbs) is considered an important critical quality attribute and requires careful characterization to ensure safe and efficacious drug products. The charge heterogeneity among mAbs is the result of chemical and enzymatic post-translational modifications and leads to the formation of acidic and basic variants that can be characterized using cation exchange chromatography (CEX). Recently, the use of mass spectrometry-compatible salt-mediated pH gradients has gained increased attention to elute the proteins from the charged stationary phase material. However, with the increasing antibody product complexity, more and more selectivity is required. Therefore, in this study, we set out to improve the selectivity by using a solvent-enriched mobile phase composition for the analysis of a variety of mAbs and bispecific antibody products. It was found that the addition of the solvents to the mobile phase appeared to modify the hydrate shell surrounding the protein and alter the retention behavior of the studied proteins. Therefore, this work demonstrates that the use of solvent-enriched mobile phase composition could be an attractive additional method parameter during method development in CEX.
Collapse
Affiliation(s)
- Bastiaan Laurens Duivelshof
- School of Pharmaceutical Sciences, University of Geneva, CMU—Rue Michel Servet 1, 1211 Geneva, Switzerland
- Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, CMU—Rue Michel Servet 1, 1211 Geneva, Switzerland
| | - Thomas Bouvarel
- School of Pharmaceutical Sciences, University of Geneva, CMU—Rue Michel Servet 1, 1211 Geneva, Switzerland
- Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, CMU—Rue Michel Servet 1, 1211 Geneva, Switzerland
| | | | | | | | - Hans Koll
- Roche Diagnostics GmbH, Nonnenwald 2, 82377 Penzberg, Germany
| | - Valentina D’Atri
- School of Pharmaceutical Sciences, University of Geneva, CMU—Rue Michel Servet 1, 1211 Geneva, Switzerland
- Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, CMU—Rue Michel Servet 1, 1211 Geneva, Switzerland
| | - Davy Guillarme
- School of Pharmaceutical Sciences, University of Geneva, CMU—Rue Michel Servet 1, 1211 Geneva, Switzerland
- Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, CMU—Rue Michel Servet 1, 1211 Geneva, Switzerland
| |
Collapse
|
6
|
Füssl F, Millán-Martín S, Bones J, Carillo S. Cation exchange chromatography on a monodisperse 3 µm particle enables extensive analytical similarity assessment of biosimilars. J Pharm Biomed Anal 2023; 234:115534. [PMID: 37343453 DOI: 10.1016/j.jpba.2023.115534] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2023] [Revised: 06/12/2023] [Accepted: 06/15/2023] [Indexed: 06/23/2023]
Abstract
Biosimilarity assessment requires extensive characterization and comparability exercises to investigate product quality attributes of an originator product and its potential biosimilar(s) and to highlight any differences between them. Performing a thorough comparison allows a shortened approval path, which also eliminates lengthy and expensive clinical trials, ensuring comparable product quality and efficacy but at lower drug prices. The wide variety of analytical methods available for biosimilar assessment ranges from biological to analytical assays, each providing orthogonal information to fully characterize biosimilar candidates. Intact native mass spectrometry (MS) has been shown to be an excellent tool for detection and monitoring of important quality attributes such as N-glycosylation, deamidation, sequence truncation and higher order structures. When combined with efficient upfront separation methods, simplification of the proteoform heterogeneity and associated complexity prior to MS analysis can be achieved. Native mass spectrometry can provide robust and accurate results within short analysis times and requires minimal sample preparation. In this study we report the use of a monodisperse strong cation exchange chromatography phase hyphenated with Orbitrap mass spectrometry (SCX-MS) to compare the best-selling biopharmaceutical product Humira® with 7 commercially approved biosimilar products. SCX-MS analysis allowed for the identification of previously described as well as so far unreported proteoforms and their relative quantitation across all samples, revealing differences in N-glycosylation and lysine truncation, as well as unique features for some products such as sialylation and N-terminal clipping. SCX-MS analysis, powered by a highly efficient separation column, enabled deep and efficient analytical comparison of biosimilar products.
Collapse
Affiliation(s)
- Florian Füssl
- National Institute for Bioprocessing Research & Training, Fosters Avenue, Mount Merrion, Blackrock, A94 X099 Co. Dublin, Ireland
| | - Silvia Millán-Martín
- National Institute for Bioprocessing Research & Training, Fosters Avenue, Mount Merrion, Blackrock, A94 X099 Co. Dublin, Ireland
| | - Jonathan Bones
- National Institute for Bioprocessing Research & Training, Fosters Avenue, Mount Merrion, Blackrock, A94 X099 Co. Dublin, Ireland; School of Chemical and Bioprocess Engineering, University College Dublin, Belfield, Dublin 4 D04 V1W8, Ireland
| | - Sara Carillo
- National Institute for Bioprocessing Research & Training, Fosters Avenue, Mount Merrion, Blackrock, A94 X099 Co. Dublin, Ireland.
| |
Collapse
|
7
|
De Fauw K, Umelo IA, Teng X, Vlyminck S, Rivera G, Brigé A, Delangle A. Theoretical charge plots as a tool for targeted and accelerated ion exchange chromatography method development of NANOBODY Ⓡ molecules. J Chromatogr A 2023; 1705:464137. [PMID: 37356365 DOI: 10.1016/j.chroma.2023.464137] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2023] [Revised: 06/04/2023] [Accepted: 06/06/2023] [Indexed: 06/27/2023]
Abstract
NANOBODYⓇ molecules are an innovative class of biotherapeutics based on heavy chain only VHH immunoglobulins. Much like canonical antibodies, they are prone to the formation of charge variants and other post-translational modifications, which can potentially impact their critical quality attributes. Therefore, establishing high-resolution product-specific methods, such as IEX chromatography, is essential for evaluating the purity of these molecules. However, due to the lower surface charge of NANOBODYⓇ molecules, their charge-based elution behavior can differ considerably from that of classical antibodies, resulting in a more extensive method development set-up for these smaller molecules. Using an initial pH screening gradient based on theoretical protein charge plots, we investigated the IEX retention behavior of eight NANOBODYⓇ molecules with a wide range of pI values (pI 5.0 to 10.0). Our findings reveal that the charge-based chromatographic behavior of NANOBODYⓇ molecules cannot be solely attributed to the isoelectric point (pI) of the protein. Rather, a molecule-specific charge threshold was identified as a critical parameter for NANOBODYⓇ molecule retention. Furthermore, the protein charge plot also showed that NANOBODYⓇ molecule elution can be characterized by a charge plateau where the net charge of the protein remains constant over a certain pH range (∼ pH 5.5 to pH 8.0), further challenging the paradigm that elution pH and pI are fixed values. The application of this theoretical approach using protein charge plots to define NANOBODYⓇ molecule charge threshold and charge plateau parameters, can reduce overall IEX method development turnaround time by at least 2-fold.
Collapse
Affiliation(s)
- Ken De Fauw
- Sanofi Large Molecules Research, NANOBODY(Ⓡ) Research Platform, Analytics, Technologiepark 21, 9052 Zwijnaarde (Ghent), Belgium
| | - Ijeoma A Umelo
- Sanofi Large Molecules Research, NANOBODY(Ⓡ) Research Platform, Analytics, Technologiepark 21, 9052 Zwijnaarde (Ghent), Belgium
| | - Xia Teng
- Sanofi Large Molecules Research, NANOBODY(Ⓡ) Research Platform, Analytics, Technologiepark 21, 9052 Zwijnaarde (Ghent), Belgium
| | - Silke Vlyminck
- Sanofi Large Molecules Research, NANOBODY(Ⓡ) Research Platform, Analytics, Technologiepark 21, 9052 Zwijnaarde (Ghent), Belgium
| | - Gustavo Rivera
- Sanofi Large Molecules Research, NANOBODY(Ⓡ) Research Platform, Analytics, Technologiepark 21, 9052 Zwijnaarde (Ghent), Belgium
| | - Ann Brigé
- Sanofi Large Molecules Research, NANOBODY(Ⓡ) Research Platform, Analytics, Technologiepark 21, 9052 Zwijnaarde (Ghent), Belgium
| | - Aurélie Delangle
- Sanofi Large Molecules Research, NANOBODY(Ⓡ) Research Platform, Analytics, Technologiepark 21, 9052 Zwijnaarde (Ghent), Belgium.
| |
Collapse
|
8
|
VanAernum ZL, Sergi JA, Dey M, Toner T, Kilgore B, Lay-Fortenbery A, Wang Y, Bian S, Kochert BA, Bothe JR, Gao X, Richardson D, Schuessler HA. Discovery and Control of Succinimide Formation and Accumulation at Aspartic Acid Residues in The Complementarity-Determining Region of a Therapeutic Monoclonal Antibody. Pharm Res 2023; 40:1411-1423. [PMID: 36627449 DOI: 10.1007/s11095-022-03462-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2022] [Accepted: 12/12/2022] [Indexed: 01/11/2023]
Abstract
PURPOSE Succinimide formation and isomerization alter the chemical and physical properties of aspartic acid residues in a protein. Modification of aspartic acid residues within complementarity-determining regions (CDRs) of therapeutic monoclonal antibodies (mAbs) can be particularly detrimental to the efficacy of the molecule. The goal of this study was to characterize the site of succinimide accumulation in the CDR of a therapeutic mAb and understand its effects on potency. Furthermore, we aimed to mitigate succinimide accumulation through changes in formulation. METHODS Accumulation of succinimide was identified through intact and reduced LC-MS mass measurements. A low pH peptide mapping method was used for relative quantitation and localization of succinimide formation in the CDR. Statistical modeling was used to correlate levels of succinimide with basic variants and potency measurements. RESULTS Succinimide accumulation in Formulation A was accelerated when stored at elevated temperatures. A strong correlation between succinimide accumulation in the CDR, an increase in basic charge variants, and a decrease in potency was observed. Statistical modeling suggest that a combination of ion exchange chromatography and potency measurements can be used to predict succinimide levels in a given sample. Reformulation of the mAb to Formulation B mitigates succinimide accumulation even after extended storage at elevated temperatures. CONCLUSION Succinimide formation in the CDR of a therapeutic mAb can have a strong negative impact on potency of the molecule. We demonstrate that thorough characterization of the molecule by LC-MS, ion exchange chromatography, and potency measurements can facilitate changes in formulation that mitigate succinimide formation and the corresponding detrimental changes in potency.
Collapse
Affiliation(s)
- Zachary L VanAernum
- Analytical Research and Development, Merck & Co., Inc., 126 E. Lincoln Ave, Rahway, NJ, 07065, USA.
| | - Joseph A Sergi
- Analytical Research and Development, Merck & Co., Inc., 126 E. Lincoln Ave, Rahway, NJ, 07065, USA
| | - Monisha Dey
- Biostatistics and Research Decision Sciences, Merck & Co., Inc., 126 E. Lincoln Ave, Rahway, NJ, 07065, USA
| | - Timothy Toner
- Analytical Research and Development, Merck & Co., Inc., 126 E. Lincoln Ave, Rahway, NJ, 07065, USA
| | - Bruce Kilgore
- Analytical Research and Development, Merck & Co., Inc., 126 E. Lincoln Ave, Rahway, NJ, 07065, USA
| | - Ashley Lay-Fortenbery
- Preclinical Development, Merck & Co., Inc, 126 E. Lincoln Ave, Rahway, NJ, 07065, USA
| | - Yi Wang
- Analytical Research and Development, Merck & Co., Inc., 126 E. Lincoln Ave, Rahway, NJ, 07065, USA
- Biologics Process and Analytical Development, National Resilience, Inc, Waltham, MA, 02451, USA
| | - Shengjie Bian
- Analytical Research and Development, Merck & Co., Inc., 126 E. Lincoln Ave, Rahway, NJ, 07065, USA
- CMC Regulatory & Technical Strategy, Amicus Therapeutics Inc. Philadelphia, Philadelphia, PA, 19104, USA
| | - Brent A Kochert
- Analytical Research and Development, Merck & Co., Inc., 126 E. Lincoln Ave, Rahway, NJ, 07065, USA
| | - Jameson R Bothe
- Analytical Research and Development, Merck & Co., Inc., 126 E. Lincoln Ave, Rahway, NJ, 07065, USA
| | - Xinliu Gao
- Analytical Research and Development, Merck & Co., Inc., 126 E. Lincoln Ave, Rahway, NJ, 07065, USA
| | - Douglas Richardson
- Analytical Research and Development, Merck & Co., Inc., 126 E. Lincoln Ave, Rahway, NJ, 07065, USA
| | - Hillary A Schuessler
- Analytical Research and Development, Merck & Co., Inc., 126 E. Lincoln Ave, Rahway, NJ, 07065, USA
| |
Collapse
|
9
|
Spanov B, Baartmans B, Olaleye O, Nicolardi S, Govorukhina N, Wuhrer M, van de Merbel NC, Bischoff R. Revealing charge heterogeneity of stressed trastuzumab at the subunit level. Anal Bioanal Chem 2023; 415:1505-1513. [PMID: 36693954 PMCID: PMC9974696 DOI: 10.1007/s00216-023-04547-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2022] [Revised: 12/24/2022] [Accepted: 01/16/2023] [Indexed: 01/26/2023]
Abstract
Trastuzumab is known to be heterogeneous in terms of charge. Stressing trastuzumab under physiological conditions (pH 7.4 and 37 °C) increases charge heterogeneity further. Separation of charge variants of stressed trastuzumab at the intact protein level is challenging due to increasing complexity making it difficult to obtain pure charge variants for further characterization. Here we report an approach for revealing charge heterogeneity of stressed trastuzumab at the subunit level by pH gradient cation-exchange chromatography. Trastuzumab subunits were generated after limited proteolytic cleavage with papain, IdeS, and GingisKHAN®. The basic pI of Fab and F(ab)2 fragments allowed to use the same pH gradient for intact protein and subunit level analysis. Baseline separation of Fab subunits was obtained after GingisKHAN® and papain digestion and the corresponding modifications were determined by LC-MS/MS peptide mapping and middle-down MALDI-ISD FT-ICR MS. The described approach allows a comprehensive charge variant analysis of therapeutic antibodies that have two or more modification sites in the Fab region.
Collapse
Affiliation(s)
- Baubek Spanov
- Department of Analytical Biochemistry, Groningen Research Institute of Pharmacy, University of Groningen, A Deusinglaan 1, 9713 AV, Groningen, The Netherlands
| | - Bas Baartmans
- Department of Analytical Biochemistry, Groningen Research Institute of Pharmacy, University of Groningen, A Deusinglaan 1, 9713 AV, Groningen, The Netherlands
| | - Oladapo Olaleye
- Department of Analytical Biochemistry, Groningen Research Institute of Pharmacy, University of Groningen, A Deusinglaan 1, 9713 AV, Groningen, The Netherlands
| | - Simone Nicolardi
- Center for Proteomics and Metabolomics, Leiden University Medical Center, 2333 ZA, Leiden, The Netherlands
| | - Natalia Govorukhina
- Department of Analytical Biochemistry, Groningen Research Institute of Pharmacy, University of Groningen, A Deusinglaan 1, 9713 AV, Groningen, The Netherlands
| | - Manfred Wuhrer
- Center for Proteomics and Metabolomics, Leiden University Medical Center, 2333 ZA, Leiden, The Netherlands
| | - Nico C van de Merbel
- Department of Analytical Biochemistry, Groningen Research Institute of Pharmacy, University of Groningen, A Deusinglaan 1, 9713 AV, Groningen, The Netherlands.,Bioanalytical Laboratory, ICON, Amerikaweg 18, 9407 TK, Assen, The Netherlands
| | - Rainer Bischoff
- Department of Analytical Biochemistry, Groningen Research Institute of Pharmacy, University of Groningen, A Deusinglaan 1, 9713 AV, Groningen, The Netherlands.
| |
Collapse
|
10
|
Kwok T, Chan SL, Shi J, Zhou M, Schaefer A, Bo T, Li V, Huang T, Chen T. Imaged capillary isoelectric focusing employing fluorocarbon and methylcellulose coated fused silica capillary for characterization of charge heterogeneity of protein biopharmaceuticals. SEPARATION SCIENCE PLUS 2023. [DOI: 10.1002/sscp.202200160] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/06/2023]
Affiliation(s)
- Teresa Kwok
- Advanced Electrophoresis Solutions Ltd. Cambridge Canada
| | - She Lin Chan
- Advanced Electrophoresis Solutions Ltd. Cambridge Canada
| | - Jessica Shi
- Faculty of Science McGill University Montreal Canada
| | - Mike Zhou
- Advanced Electrophoresis Solutions Ltd. Cambridge Canada
| | - Anna Schaefer
- Advanced Electrophoresis Solutions Ltd. Cambridge Canada
| | - Tao Bo
- Advanced Electrophoresis Solutions Ltd. Cambridge Canada
| | - Victor Li
- Advanced Electrophoresis Solutions Ltd. Cambridge Canada
| | - Tiemin Huang
- Advanced Electrophoresis Solutions Ltd. Cambridge Canada
| | - Tong Chen
- Advanced Electrophoresis Solutions Ltd. Cambridge Canada
| |
Collapse
|
11
|
Alhazmi HA, Albratty M. Analytical Techniques for the Characterization and Quantification of Monoclonal Antibodies. Pharmaceuticals (Basel) 2023; 16:291. [PMID: 37259434 PMCID: PMC9967501 DOI: 10.3390/ph16020291] [Citation(s) in RCA: 12] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2022] [Revised: 01/17/2023] [Accepted: 01/18/2023] [Indexed: 08/12/2023] Open
Abstract
Monoclonal antibodies (mAbs) are a fast-growing class of biopharmaceuticals. They are widely used in the identification and detection of cell makers, serum analytes, and pathogenic agents, and are remarkably used for the cure of autoimmune diseases, infectious diseases, or malignancies. The successful application of therapeutic mAbs is based on their ability to precisely interact with their appropriate target sites. The precision of mAbs rely on the isolation techniques delivering pure, consistent, stable, and safe lots that can be used for analytical, diagnostic, or therapeutic applications. During the creation of a biologic, the key quality features of a particular mAb, such as structure, post-translational modifications, and activities at the biomolecular and cellular levels, must be characterized and profiled in great detail. This implies the requirement of powerful state of the art analytical techniques for quality control and characterization of mAbs. Until now, various analytical techniques have been developed to characterize and quantify the mAbs according to the regulatory guidelines. The present review summarizes the major techniques used for the analyses of mAbs which include chromatographic, electrophoretic, spectroscopic, and electrochemical methods in addition to the modifications in these methods for improving the quality of mAbs. This compilation of major analytical techniques will help students and researchers to have an overview of the methodologies employed by the biopharmaceutical industry for structural characterization of mAbs for eventual release of therapeutics in the drug market.
Collapse
Affiliation(s)
- Hassan A. Alhazmi
- Department of Pharmaceutical Chemistry and Pharmacognosy, College of Pharmacy, Jazan University, Jazan 45142, Saudi Arabia
- Substance Abuse and Toxicology Research Centre, Jazan University, Jazan 45142, Saudi Arabia
| | - Mohammed Albratty
- Department of Pharmaceutical Chemistry and Pharmacognosy, College of Pharmacy, Jazan University, Jazan 45142, Saudi Arabia
| |
Collapse
|
12
|
Yap WY, Loo LW, Sha HX, Hwang JS. Enhanced production of recombinant HALT-1 pore-forming toxin using two-step chromatographic procedure. MethodsX 2023; 10:102073. [PMID: 36865650 PMCID: PMC9971028 DOI: 10.1016/j.mex.2023.102073] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2022] [Accepted: 02/08/2023] [Indexed: 02/13/2023] Open
Abstract
Hydra actinoporin-like toxin-1 (HALT-1) has been isolated from Hydra magnipapillata and is highly cytolytic against various human cells including erythrocyte. Previously, recombinant HALT-1 (rHALT-1) was expressed in Escherichia coli and purified by the nickel affinity chromatography. In this study, we improved the purification of rHALT-1 by two-step purifications. Bacterial cell lysate containing rHALT-1 was subjected to the sulphopropyl (SP) cation exchange chromatography with different buffers, pHs, and NaCl concentrations. The results indicated that both phosphate and acetate buffers facilitated the strong binding of rHALT-1 to SP resins, and the buffers containing 150 mM and 200 mM NaCl, respectively, removed protein impurities but retain most rHALT-1 in the column. When combining the nickel affinity chromatography and the SP cation exchange chromatography, the purity of rHALT-1 was highly enhanced. In subsequent cytotoxicity assays, 50% of cells could be lysed at ∼18 and ∼22 µg/mL of rHALT-1 purified with phosphate and acetate buffers, respectively.•HALT-1 is a soluble α-pore-forming toxin of 18.38 kDa.•rHALT-1 was purified by nickel affinity chromatography followed by SP cation exchange chromatography.•The cytotoxicity of purified rHALT-1 using 2-step purifications via either phosphate or acetate buffer was comparable to those previously reported.
Collapse
Affiliation(s)
- Wei Yuen Yap
- Department of Biological Sciences, School of Medical and Life Sciences, Sunway University, Selangor Darul Ehsan, Malaysia
| | - Lok Wenn Loo
- Department of Biological Sciences, School of Medical and Life Sciences, Sunway University, Selangor Darul Ehsan, Malaysia
| | - Hong Xi Sha
- Department of Biological Sciences, School of Medical and Life Sciences, Sunway University, Selangor Darul Ehsan, Malaysia
| | - Jung Shan Hwang
- Department of Medical Sciences, School of Medical and Life Sciences, Sunway University, Selangor Darul Ehsan, Malaysia,Corresponding author.
| |
Collapse
|
13
|
Zhang X, Kwok T, Zhou M, Du M, Li V, Bo T, Huang T, Chen T. Imaged capillary isoelectric focusing (icIEF) tandem high resolution mass spectrometry for charged heterogeneity of protein drugs in biopharmaceutical discovery. J Pharm Biomed Anal 2023; 224:115178. [PMID: 36435084 DOI: 10.1016/j.jpba.2022.115178] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2022] [Revised: 11/16/2022] [Accepted: 11/20/2022] [Indexed: 11/23/2022]
Abstract
Since the first commercial imaged capillary isoelectric focusing (icIEF) instrument was developed twenty years ago, the technology has become the gold standard of quality and manufacturing process control in the biopharmaceutical industry. This is owing to its high-resolution and high-throughput characterization of protein charge heterogeneity. In addition to a charge variant profiling, mass spectrometry (MS) analyses are also desirable to obtain an in-tact molecular weight (MW) and further identification of these charged species. While offline fractionation technologies including isoelectric focusing (IEF) and free flow electrophoresis (FFE) followed by liquid chromatography (LC)-mass spectrometry (MS) coupling have been employed for this purpose, there have been much fewer reported applications of icIEF-based MS connection and fraction collection. Factors that have impeded the development of these icIEF applications include difficulties with a direct connection to the MS interface as well as high background signal of carrier ampholytes and incompatible coated capillary cartridges. In this work, we developed a robust and flexible icIEF-MS platform which overcomes these challenges to achieve both the rapid icIEF separation and high-resolution MS (HRMS) identification of protein charged variants simultaneously. We demonstrate how this methodology proves highly-sensitive and highly reliable for the characterization of commercial monoclonal antibodies (mAbs) and antibody-drug-conjugates (ADCs). The whole workflow of icIEF-MS for protein heterogeneity is straight forward and accurate and can be performed within 45 min. Furthermore, the developed icIEF-MS configuration can flexibly switch to icIEF-based fraction collection model allowing the user to perform additional in-depth characterization such as peptide mapping by high performance liquid chromatography (HPLC) tandem mass spectrometry (LC-MS/MS).
Collapse
Affiliation(s)
| | - Teresa Kwok
- Advanced Electrophoresis Solution LTD, Cambridge, Canada
| | - Mike Zhou
- Advanced Electrophoresis Solution LTD, Cambridge, Canada
| | - Min Du
- Themo Fisher Scientific, Massachusetts, USA.
| | - Victor Li
- Advanced Electrophoresis Solution LTD, Cambridge, Canada
| | - Tao Bo
- Advanced Electrophoresis Solution LTD, Cambridge, Canada
| | - Tiemin Huang
- Advanced Electrophoresis Solution LTD, Cambridge, Canada
| | - Tong Chen
- Advanced Electrophoresis Solution LTD, Cambridge, Canada.
| |
Collapse
|
14
|
Wu G, Yu C, Wang W, Du J, Fu Z, Xu G, Li M, Wang L. Mass Spectrometry-Based Charge Heterogeneity Characterization of Therapeutic mAbs with Imaged Capillary Isoelectric Focusing and Ion-Exchange Chromatography as Separation Techniques. Anal Chem 2023; 95:2548-2560. [PMID: 36656605 DOI: 10.1021/acs.analchem.2c05071] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
Abstract
Imaged capillary isoelectric focusing (icIEF) and ion-exchange chromatography (IEX) are two essential techniques that are routinely used for charge variant analysis of therapeutic monoclonal antibodies (mAbs) during their development and in quality control. These two techniques that separate mAb charge variants based on different mechanisms and IEX have been developed as front-end separation techniques for online mass spectrometry (MS) detection, which is robust for intact protein identification. Recently, an innovative, coupled icIEF-MS technology has been constructed for protein charge variant analysis in our laboratory. In this study, icIEF-MS developed and strong cation exchange (SCX)-MS were optimized for charge heterogeneity characterization of a diverse of mAbs and their results were compared based on methodological validation. It was found that icIEF-MS outperformed SCX-MS in this study by demonstrating outstanding sensitivity, low carryover effect, accurate protein identification, and higher separation resolution although SCX-MS contributed to higher analysis throughput. Ultimately, integrating our novel icIEF-HRMS analysis with the more common SCX-MS can provide a promising and comprehensive strategy for accelerating the development of complex protein therapeutics.
Collapse
Affiliation(s)
- Gang Wu
- Key Laboratory of the Ministry of Health for Research on Quality and Standardization of Biotech Products, National Institutes for Food and Drug Control, Daxing District, Beijing 102629, China
| | - Chuanfei Yu
- Key Laboratory of the Ministry of Health for Research on Quality and Standardization of Biotech Products, National Institutes for Food and Drug Control, Daxing District, Beijing 102629, China
| | - Wenbo Wang
- Key Laboratory of the Ministry of Health for Research on Quality and Standardization of Biotech Products, National Institutes for Food and Drug Control, Daxing District, Beijing 102629, China
| | - Jialiang Du
- Key Laboratory of the Ministry of Health for Research on Quality and Standardization of Biotech Products, National Institutes for Food and Drug Control, Daxing District, Beijing 102629, China
| | - Zhihao Fu
- Key Laboratory of the Ministry of Health for Research on Quality and Standardization of Biotech Products, National Institutes for Food and Drug Control, Daxing District, Beijing 102629, China
| | - Gangling Xu
- Key Laboratory of the Ministry of Health for Research on Quality and Standardization of Biotech Products, National Institutes for Food and Drug Control, Daxing District, Beijing 102629, China
| | - Meng Li
- Key Laboratory of the Ministry of Health for Research on Quality and Standardization of Biotech Products, National Institutes for Food and Drug Control, Daxing District, Beijing 102629, China
| | - Lan Wang
- Key Laboratory of the Ministry of Health for Research on Quality and Standardization of Biotech Products, National Institutes for Food and Drug Control, Daxing District, Beijing 102629, China
| |
Collapse
|
15
|
Kwok T, Zhou M, Schaefer A, Bo T, Li V, Huang T, Chen T. Fractionation and online mass spectrometry based on imaged capillary isoelectric focusing (icIEF) for characterizing charge heterogeneity of therapeutic antibody. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2023; 15:411-418. [PMID: 36537584 DOI: 10.1039/d2ay01670b] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/17/2023]
Abstract
Imaged capillary isoelectric focusing (icIEF) technology has been proved to be robust for the characterization of protein charge heterogeneity due to its high-resolution pI discrimination and high-throughput. Although high performance liquid chromatography (HPLC) tandem mass spectrometry (MS) and offline fraction collection technologies including isoelectric focusing (IEF), ion exchange chromatography (IEX) and free flow electrophoresis (FFE) have been widely utilized for protein charge variant characterization, there are a few applications of MS coupling with icIEF as a front-separation technique and related fractionation technologies for protein charge heterogeneity. However, the application of icIEF-MS has been much less frequent due to difficulties in MS interface, compatible ampholyte and coated capillary cartridge designation, ultimately impeding the breadth of icIEF applications in protein charge heterogeneity. In this study, a therapeutic monoclonal antibody (mAb-M-AT) was used for its charge variant characterization on an integrated icIEF platform with functions including analytical profiling, MS online coupling and fraction collection for charge heterogeneities. The main protein component and its four charge variants were identified using direct icIEF-MS coupling. Additionally, the two major acidic and basic charge variants were collected using preparative fractionation after the protein focused in the separation capillary. The identity of the fractions was confirmed by LC-MS at intact protein level and the results were consistent with those using icIEF-MS online coupling. The multiple operation modes of the icIEF platform described above can be rapidly and flexibly switched just by changing customized capillary separation cartridges without drastically altering instrument configuration. The whole workflow of icIEF-based profiling, fractionation and MS online coupling for protein heterogeneity is straightforward, reliable, and accurate, thus providing comprehensive solutions for in-depth protein heterogeneity characterization.
Collapse
Affiliation(s)
- Teresa Kwok
- Advanced Electrophoresis Solution Ltd, Cambridge, Canada.
| | - Mike Zhou
- Advanced Electrophoresis Solution Ltd, Cambridge, Canada.
| | - Anna Schaefer
- Advanced Electrophoresis Solution Ltd, Cambridge, Canada.
| | - Tao Bo
- Advanced Electrophoresis Solution Ltd, Cambridge, Canada.
| | - Victor Li
- Advanced Electrophoresis Solution Ltd, Cambridge, Canada.
| | - Tiemin Huang
- Advanced Electrophoresis Solution Ltd, Cambridge, Canada.
| | - Tong Chen
- Advanced Electrophoresis Solution Ltd, Cambridge, Canada.
| |
Collapse
|
16
|
Kwok T, Chan SL, Zhou M, Schaefer A, Bo T, Huang T, Li V, Chen T. High‐efficient characterization of complex protein drugs by imaged capillary isoelectric focusing with high‐resolution ampholytes. SEPARATION SCIENCE PLUS 2022. [DOI: 10.1002/sscp.202200142] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/03/2022]
Affiliation(s)
- Teresa Kwok
- Advanced Electrophoresis Solution Ltd Cambridge Canada
| | - She Lin Chan
- Advanced Electrophoresis Solution Ltd Cambridge Canada
| | - Mike Zhou
- Advanced Electrophoresis Solution Ltd Cambridge Canada
| | - Anna Schaefer
- Advanced Electrophoresis Solution Ltd Cambridge Canada
| | - Tao Bo
- Advanced Electrophoresis Solution Ltd Cambridge Canada
| | - Tiemin Huang
- Advanced Electrophoresis Solution Ltd Cambridge Canada
| | - Victor Li
- Advanced Electrophoresis Solution Ltd Cambridge Canada
| | - Tong Chen
- Advanced Electrophoresis Solution Ltd Cambridge Canada
| |
Collapse
|
17
|
Schwahn AB, Baek J, Lin S, Pohl CA, Cook K. A Universal Eluent System for Method Scouting and Separation of Biotherapeutic Proteins by Ion-Exchange, Size-Exclusion, and Hydrophobic Interaction Chromatography. Anal Chem 2022; 94:16369-16375. [DOI: 10.1021/acs.analchem.2c03531] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Affiliation(s)
| | - Julia Baek
- Thermo Fisher Scientific, Sunnyvale, California94085, United States
| | - Shanhua Lin
- Thermo Fisher Scientific, Sunnyvale, California94085, United States
| | | | - Ken Cook
- Thermo Fisher Scientific, Hemel Hempstead, HertfordshireHP2 7GE, U.K
| |
Collapse
|
18
|
Bouvarel T, Duivelshof BL, Camperi J, Schlothauer T, Knaupp A, Stella C, Guillarme D. Extending the performance of FcRn and FcγRIIIa affinity liquid chromatography for protein biopharmaceuticals. J Chromatogr A 2022; 1682:463518. [PMID: 36155073 DOI: 10.1016/j.chroma.2022.463518] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2022] [Revised: 09/15/2022] [Accepted: 09/16/2022] [Indexed: 10/14/2022]
Abstract
Affinity liquid chromatography using FcRn and FcγRIIIa columns can provide important information on the drug effector functions and the unique PK/PD properties of therapeutic mAbs. In this study, we propose a unique strategy to improve the performance of affinity chromatography by applying pH-gradient programs that incorporate multi-isocratic and negative gradient segments. These alternative gradient programs are known to greatly improve the separation of large solutes that follow a "bind-and-elute" type retention behavior. First, judicious optimization of the mobile phase compositions was performed to obtain a linear pH response. Then, with the developed strategy using multi-isocratic analysis conditions, the FcRn affinity separation selectivity for the analysis of oxidized mAb species was greatly improved. Furthermore, the introduction of negative gradient segments after each eluted peak improved the resolution between multiple glycosylated mAb species on the FcγRIIIa column. Therefore, this work provides a new strategy to improve the performance of affinity chromatography with mAb species, and could assist in the development of more accurate binding assays for important critical quality attributes related to FcRn and FcγRIIIa binding.
Collapse
Affiliation(s)
- Thomas Bouvarel
- School of Pharmaceutical Sciences, University of Geneva, CMU - Rue Michel Servet 1, 1211 Geneva 4, Switzerland; Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, CMU - Rue Michel Servet 1, 1211 Geneva 4, Switzerland
| | - Bastiaan L Duivelshof
- School of Pharmaceutical Sciences, University of Geneva, CMU - Rue Michel Servet 1, 1211 Geneva 4, Switzerland; Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, CMU - Rue Michel Servet 1, 1211 Geneva 4, Switzerland
| | - Julien Camperi
- Protein Analytical Chemistry, Genentech, 1 DNA Way, South San Francisco, CA, 94080, USA
| | - Tilman Schlothauer
- Large Molecule Research, Roche Innovation Center Munich, Nonnenwald 2, D-82377 Penzberg, Germany
| | - Alexander Knaupp
- Large Molecule Research, Roche Innovation Center Munich, Nonnenwald 2, D-82377 Penzberg, Germany
| | - Cinzia Stella
- Protein Analytical Chemistry, Genentech, 1 DNA Way, South San Francisco, CA, 94080, USA
| | - Davy Guillarme
- School of Pharmaceutical Sciences, University of Geneva, CMU - Rue Michel Servet 1, 1211 Geneva 4, Switzerland; Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, CMU - Rue Michel Servet 1, 1211 Geneva 4, Switzerland.
| |
Collapse
|
19
|
Rakotondravao HM, Takahashi R, Takai T, Sakoda Y, Horiuchi JI, Kumada Y. Control of Accessible Surface Areas and Height Equivalent to a Theoretical Plate using Grafted Dextran during Anion-Exchange Chromatography of Therapeutic Proteins. JOURNAL OF CHEMICAL ENGINEERING OF JAPAN 2022. [DOI: 10.1252/jcej.22we035] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Affiliation(s)
| | | | | | | | - Jun-Ichi Horiuchi
- Department of Molecular Chemistry and Engineering, Kyoto Institute of Technology
| | - Yoichi Kumada
- Department of Molecular Chemistry and Engineering, Kyoto Institute of Technology
| |
Collapse
|
20
|
He X, ElNaggar M, Ostrowski MA, Guttman A, Gentalen E, Sperry J. Evaluation of an icIEF-MS system for comparable charge variant analysis of biotherapeutics with rapid peak identification by mass spectrometry. Electrophoresis 2022; 43:1215-1222. [PMID: 35286725 PMCID: PMC9322286 DOI: 10.1002/elps.202100295] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2021] [Revised: 02/02/2022] [Accepted: 02/04/2022] [Indexed: 01/27/2023]
Abstract
Protein therapeutics are usually produced in heterogeneous forms during bioproduction and bioprocessing. Heterogeneity results from post‐translational modifications that can yield charge variants and require characterization throughout product development and manufacturing. Isoelectric focusing (IEF) with UV detection is one of the most common methods to evaluate protein charge heterogeneity in the biopharmaceutical industry. To identify charge variant peaks, a new imaged microfluidic chip‐based isoelectric focusing (icIEF) system coupled directly to mass spectrometry was recently reported. Bridging is required to demonstrate comparability between existing and new technology. As such, here we demonstrate the comparability of the pI value measurement and relative charge species distributions between the icIEF‐MS system and the control data from a frequently utilized methodology in the biopharmaceutical industry for several blinded development‐phase biopharmaceutical monoclonal antibodies across a wide pI range of 7.3–9.0. Hyphenation of the icIEF system with mass spectrometry enabled direct and detailed structural determination of a test molecule, with masses suggesting acidic and basic shifts are caused by sialic acid additions and the presence of unprocessed lysine residues. In addition, MS analysis further identified several low‐abundance glycoforms. The icIEF‐MS system provides sample quantification, characterization, and identification of mAb proteoforms without sacrificing icIEF quantification comparability or speed.
Collapse
Affiliation(s)
| | | | | | - Andras Guttman
- Horvath Csaba Memorial Laboratory of Bioseparation Sciences, University of Debrecen, Hungary.,Previously with SCIEX
| | | | | |
Collapse
|
21
|
Liu AP, Yan Y, Wang S, Li N. Coupling Anion Exchange Chromatography with Native Mass Spectrometry for Charge Heterogeneity Characterization of Monoclonal Antibodies. Anal Chem 2022; 94:6355-6362. [PMID: 35420790 PMCID: PMC9047409 DOI: 10.1021/acs.analchem.2c00707] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Despite the recent success of coupling anion exchange chromatography with native mass spectrometry (AEX-MS) to study anionic proteins, the utility of AEX-MS methods in therapeutic monoclonal antibody (mAb) characterization has been limited. In this work, we developed and optimized a salt gradient-based AEX-MS method and explored its utility in charge variant analysis of therapeutic mAbs. We demonstrated that, although the developed AEX-MS method is less useful for IgG1 molecules that have higher isoelectric points (pIs), it is an attractive alternative for charge variant analysis of IgG4 molecules. By elevating the column temperature and lowering the mAb pI through PNGase F-mediated deglycosylation, the chromatographical resolution from AEX separation can be significantly improved. We also demonstrated that, after PNGase F and IdeS digestion, the AEX-MS method exhibited excellent resolving power for multiple attributes in the IgG4 Fc region, including unprocessed C-terminal Lys, N-glycosylation occupancy, and several conserved Fc deamidations, making it ideally suited for multiple attribute monitoring (MAM). Through fractionation and peptide mapping analysis, we also demonstrated that the developed AEX-MS method can provide site-specific and isoform-resolved separation of Fc deamidation products, allowing rapid and artifact-free quantitation of these modifications without performing bottom-up analysis.
Collapse
Affiliation(s)
- Anita P Liu
- Analytical Chemistry Group, Regeneron Pharmaceuticals Inc., 777 Old Saw Mill River Road, Tarrytown, New York 10591-6707, United States
| | - Yuetian Yan
- Analytical Chemistry Group, Regeneron Pharmaceuticals Inc., 777 Old Saw Mill River Road, Tarrytown, New York 10591-6707, United States
| | - Shunhai Wang
- Analytical Chemistry Group, Regeneron Pharmaceuticals Inc., 777 Old Saw Mill River Road, Tarrytown, New York 10591-6707, United States
| | - Ning Li
- Analytical Chemistry Group, Regeneron Pharmaceuticals Inc., 777 Old Saw Mill River Road, Tarrytown, New York 10591-6707, United States
| |
Collapse
|
22
|
Jaffar-Aghaei M, Khanipour F, Maghsoudi A, Sarvestani R, Mohammadian M, Maleki M, Havasi F, Rahmani H, Karagah AH, Kazemali MR. QbD-guided pharmaceutical development of Pembrolizumab biosimilar candidate PSG-024 propelled to industry meeting primary requirements of comparability to Keytruda®. Eur J Pharm Sci 2022; 173:106171. [DOI: 10.1016/j.ejps.2022.106171] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2021] [Revised: 02/13/2022] [Accepted: 03/17/2022] [Indexed: 11/03/2022]
|
23
|
Chapel S, Rouvière F, Guibal P, Mathieu D, Heinisch S. Development of a sub-hour on-line comprehensive cation exchange chromatography x RPLC method hyphenated to HRMS for the characterization of lysine-linked antibody-drug conjugates. Talanta 2021; 240:123174. [PMID: 35026643 DOI: 10.1016/j.talanta.2021.123174] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2021] [Revised: 12/22/2021] [Accepted: 12/23/2021] [Indexed: 10/19/2022]
Abstract
This study details the development of on-line two-dimensional liquid chromatography (2D-LC) methods combining cation-exchange chromatography (CEX) and reversed-phase liquid chromatography (RPLC) for the separation of the charge variants of a lysine-linked antibody-drug conjugate (ADC). This combination gives an excellent example of the potential benefits of 2D-LC approaches for the analysis of such complex protein formats. CEX is considered the reference technique for the separation of protein charge variants but its retention mechanism usually requires the use of a high concentration of non-volatile salts, which impedes its compatibility with MS detection. In this context, the use of an on-line 2D-LC-MS approach not only allows on-line desalting and indirect coupling of CEX with mass spectrometry (MS) detection but it also provides increased and complementary information within a single analysis. The first part of this study was devoted to the choice of stationary phases and the optimization of chromatographic conditions in both dimensions. Based on the results obtained in 1D-CEX with ultraviolet detection (UV) and 1D-RPLC with UV and high-resolution mass spectrometry (HRMS) detections, an on-line comprehensive two-dimensional liquid chromatography method combining CEX and RPLC was developed. The last part of this study was devoted to the identification of the separated species using HRMS detection and in the comparison of three ADC samples exposed to different durations of thermal stress.
Collapse
Affiliation(s)
- Soraya Chapel
- Université de Lyon, Institut des Sciences Analytiques, UMR 5280, CNRS, 5 rue de la Doua, 69100, Villeurbanne, France
| | - Florent Rouvière
- Université de Lyon, Institut des Sciences Analytiques, UMR 5280, CNRS, 5 rue de la Doua, 69100, Villeurbanne, France
| | - Pierre Guibal
- Sanofi Aventis R&D, 1 Impasse des Ateliers, 94400, Vitry-sur-Seine, France
| | - Delphine Mathieu
- Sanofi Aventis R&D, 1 Impasse des Ateliers, 94400, Vitry-sur-Seine, France
| | - Sabine Heinisch
- Université de Lyon, Institut des Sciences Analytiques, UMR 5280, CNRS, 5 rue de la Doua, 69100, Villeurbanne, France.
| |
Collapse
|
24
|
Capillary electrophoresis and the biopharmaceutical industry: Therapeutic protein analysis and characterization. Trends Analyt Chem 2021. [DOI: 10.1016/j.trac.2021.116407] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
|
25
|
Spanov B, Olaleye O, Lingg N, Bentlage AEH, Govorukhina N, Hermans J, van de Merbel N, Vidarsson G, Jungbauer A, Bischoff R. Change of charge variant composition of trastuzumab upon stressing at physiological conditions. J Chromatogr A 2021; 1655:462506. [PMID: 34492576 DOI: 10.1016/j.chroma.2021.462506] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2021] [Revised: 08/23/2021] [Accepted: 08/25/2021] [Indexed: 01/16/2023]
Abstract
Cation-exchange chromatography is a widely used approach to study charge heterogeneity of monoclonal antibodies. Heterogeneity may arise both in vitro and in vivo because of the susceptibility of monoclonal antibodies to undergo chemical modifications. Modifications may adversely affect the potency of the drug, induce immunogenicity or affect pharmacokinetics. In this study, we evaluated the application of optimized pH gradient systems for the separation of charge variants of trastuzumab after forced degradation study. pH gradient-based elution resulted in high-resolution separation of some 20 charge variants after 3 weeks at 37°C under physiological conditions. The charge variants were further characterized by LC-MS-based peptide mapping. There was no significant difference in the binding properties to HER2 or a range of Fcγ receptors between non-stressed and stressed trastuzumab.
Collapse
Affiliation(s)
- Baubek Spanov
- Department of Analytical Biochemistry, Groningen Research Institute of Pharmacy, University of Groningen, A Deusinglaan 1, 9713 AV Groningen, the Netherlands
| | - Oladapo Olaleye
- Department of Analytical Biochemistry, Groningen Research Institute of Pharmacy, University of Groningen, A Deusinglaan 1, 9713 AV Groningen, the Netherlands
| | - Nico Lingg
- Department of Biotechnology, University of Natural Resources and Life Sciences, Vienna, Muthgasse 18, A-1190 Vienna, Austria
| | - Arthur E H Bentlage
- Department of Experimental Immunohematology, Sanquin Research and Landsteiner Laboratory, Academic Medical Center, University of Amsterdam, the Netherlands
| | - Natalia Govorukhina
- Department of Analytical Biochemistry, Groningen Research Institute of Pharmacy, University of Groningen, A Deusinglaan 1, 9713 AV Groningen, the Netherlands
| | - Jos Hermans
- Department of Analytical Biochemistry, Groningen Research Institute of Pharmacy, University of Groningen, A Deusinglaan 1, 9713 AV Groningen, the Netherlands
| | - Nico van de Merbel
- Department of Analytical Biochemistry, Groningen Research Institute of Pharmacy, University of Groningen, A Deusinglaan 1, 9713 AV Groningen, the Netherlands; Bioanalytical Laboratory, PRA Health Sciences, Early Development Services, Westerbrink 3, 9405 BJ Assen, the Netherlands
| | - Gestur Vidarsson
- Department of Experimental Immunohematology, Sanquin Research and Landsteiner Laboratory, Academic Medical Center, University of Amsterdam, the Netherlands
| | - Alois Jungbauer
- Department of Biotechnology, University of Natural Resources and Life Sciences, Vienna, Muthgasse 18, A-1190 Vienna, Austria
| | - Rainer Bischoff
- Department of Analytical Biochemistry, Groningen Research Institute of Pharmacy, University of Groningen, A Deusinglaan 1, 9713 AV Groningen, the Netherlands.
| |
Collapse
|
26
|
Fekete S, Murisier A, Lauber M, Guillarme D. Empirical correction of non-linear pH gradients and a tool for application to protein ion exchange chromatography. J Chromatogr A 2021; 1651:462320. [PMID: 34144399 DOI: 10.1016/j.chroma.2021.462320] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2021] [Revised: 05/27/2021] [Accepted: 05/29/2021] [Indexed: 10/21/2022]
Abstract
This concept article reports a practical solution to improve the linearity of effluent pH response as observed in pH gradient cation exchange chromatography (CEX). When performing pH gradient CEX, it is not easy to develop buffer systems that will universally provide pH response proportional with the mobile phase (buffer) composition. It is an especially challenging pursuit when exploring MS compatible buffers (e.g. ammonium-acetate, ammonium-carbonate). In addition to "non-proportional" behavior from the mobile phase composition, the chromatographic column itself will sometimes impose an unpredictable impact on the effluent pH. Here, we propose a simple approach based on the on-line measurement of effluent pH response, conversion of pH to mobile phase volume fraction (φ) and then generation of the inverse response function in the time domain. In the end, when setting the inverse function as the gradient program instead of a linear gradient, an improved - ideally linear - pH response can be produced. A simple Excel tool was developed to assist analysts with this correction procedure, and it has been made available by download for public use.
Collapse
Affiliation(s)
- Szabolcs Fekete
- Waters Corporation, located in CMU-Rue Michel Servet 1, 1211 Geneva 4, Switzerland.
| | - Amarande Murisier
- School of Pharmaceutical Sciences, University of Geneva, CMU-Rue Michel Servet 1, 1211 Geneva 4, Switzerland; Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, CMU-Rue Michel Servet 1, 1211 Geneva 4, Switzerland
| | - Matthew Lauber
- Waters Corporation, 34 Maple Street, Milford, MA 01757-3696, United States
| | - Davy Guillarme
- School of Pharmaceutical Sciences, University of Geneva, CMU-Rue Michel Servet 1, 1211 Geneva 4, Switzerland; Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, CMU-Rue Michel Servet 1, 1211 Geneva 4, Switzerland
| |
Collapse
|
27
|
Yüce M, Sert F, Torabfam M, Parlar A, Gürel B, Çakır N, Dağlıkoca DE, Khan MA, Çapan Y. Fractionated charge variants of biosimilars: A review of separation methods, structural and functional analysis. Anal Chim Acta 2021; 1152:238189. [PMID: 33648647 DOI: 10.1016/j.aca.2020.12.064] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2020] [Revised: 12/28/2020] [Accepted: 12/29/2020] [Indexed: 12/21/2022]
Abstract
The similarity between originator and biosimilar monoclonal antibody candidates are rigorously assessed based on primary, secondary, tertiary, quaternary structures, and biological functions. Minor differences in such parameters may alter target-binding, potency, efficacy, or half-life of the molecule. The charge heterogeneity analysis is a prerequisite for all biotherapeutics. Monoclonal antibodies are prone to enzymatic or non-enzymatic structural modifications during or after the production processes, leading to the formation of fragments or aggregates, various glycoforms, oxidized, deamidated, and other degraded residues, reduced Fab region binding activity or altered FcR binding activity. Therefore, the charge variant profiles of the monoclonal antibodies must be regularly and thoroughly evaluated. Comparative structural and functional analysis of physically separated or fractioned charged variants of monoclonal antibodies has gained significant attention in the last few years. The fraction-based charge variant analysis has proved very useful for the biosimilar candidates comprising of unexpected charge isoforms. In this report, the key methods for the physical separation of monoclonal antibody charge variants, structural and functional analyses by liquid chromatography-mass spectrometry, and surface plasmon resonance techniques were reviewed.
Collapse
Affiliation(s)
- Meral Yüce
- Sabanci University, SUNUM Nanotechnology Research and Application Center, 34956, Istanbul, Turkey.
| | - Fatma Sert
- Sabanci University, Faculty of Engineering and Natural Sciences, 34956, Istanbul, Turkey; ILKO ARGEM Biotechnology R&D Center, 34906, Pendik, Istanbul, Turkey
| | - Milad Torabfam
- Sabanci University, Faculty of Engineering and Natural Sciences, 34956, Istanbul, Turkey
| | - Ayhan Parlar
- Sabanci University, Faculty of Engineering and Natural Sciences, 34956, Istanbul, Turkey
| | - Büşra Gürel
- Sabanci University, SUNUM Nanotechnology Research and Application Center, 34956, Istanbul, Turkey
| | - Nilüfer Çakır
- Sabanci University, Faculty of Engineering and Natural Sciences, 34956, Istanbul, Turkey; ILKO ARGEM Biotechnology R&D Center, 34906, Pendik, Istanbul, Turkey
| | - Duygu E Dağlıkoca
- ILKO ARGEM Biotechnology R&D Center, 34906, Pendik, Istanbul, Turkey
| | - Mansoor A Khan
- Texas A&M Health Sciences Centre, Irma Lerma Rangel College of Pharmacy, TX, 77843, USA
| | - Yılmaz Çapan
- ILKO ARGEM Biotechnology R&D Center, 34906, Pendik, Istanbul, Turkey; Hacettepe University, Faculty of Pharmacy, 06100, Ankara, Turkey.
| |
Collapse
|