1
|
Dou Q, Zhao J, Lin M, Liu W, Xiang P. Carbon fiber-sampling combined flame ionization mass spectrometry for direct analysis of drugs in oral fluid. J Chromatogr B Analyt Technol Biomed Life Sci 2024; 1239:124130. [PMID: 38640791 DOI: 10.1016/j.jchromb.2024.124130] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2024] [Revised: 04/09/2024] [Accepted: 04/16/2024] [Indexed: 04/21/2024]
Abstract
Drug-impaired driving poses a significant risk of collisions and other hazardous accidents, emphasizing the urgent need for simple and rapid roadside detection methods. Oral fluid, as an easily collectible and non-invasive test material, has gained widespread use in detecting drug-impaired driving. In this study, we have devised a method for direct sampling using a carbon fiber bundle combined with flame ionization mass spectrometry. The essence of this method lies in the synergy between the adsorption properties of carbon fiber and the plasma characteristics of the flame. Leveraging the strong adsorption capabilities of the carbon fiber bundle allows for the use of a minimal sample size (<100 μL) during sampling, presenting a distinct advantage in the roadside inspection and sampling process. Throughout the flame ionization process, proteins and salts within the oral fluid matrix adhere well to the carbon fiber bundle, while small molecule targets can be efficiently desorbed and react with charged species in the flame, leading to ionization. The results demonstrate the successful development of carbon fiber-sampling combined flame ionization mass spectrometry, capable of qualitative and quantitative analysis of drugs in oral fluid without the need for sample pre-treatment. Its quantitative capabilities are sufficient for real sample detection, providing an effective analytical method for the roadside detection of drugs in oral fluids.
Collapse
Affiliation(s)
- Quanlu Dou
- School of Pharmacy, Yantai University, Yantai 264005, China; Department of Forensic Toxicology, Shanghai Key Laboratory of Forensic Medicine, Shanghai Forensic Service Platform, Academy of Forensic Science, Shanghai 200063, China
| | - Junbo Zhao
- Department of Forensic Toxicology, Shanghai Key Laboratory of Forensic Medicine, Shanghai Forensic Service Platform, Academy of Forensic Science, Shanghai 200063, China
| | - Meiting Lin
- Department of Forensic Toxicology, Shanghai Key Laboratory of Forensic Medicine, Shanghai Forensic Service Platform, Academy of Forensic Science, Shanghai 200063, China
| | - Wanhui Liu
- School of Pharmacy, Yantai University, Yantai 264005, China.
| | - Ping Xiang
- Department of Forensic Toxicology, Shanghai Key Laboratory of Forensic Medicine, Shanghai Forensic Service Platform, Academy of Forensic Science, Shanghai 200063, China.
| |
Collapse
|
2
|
Fan J, Ma W, Yu Y, Li Y, Nie Z. Recent advances in entirely hand-held ionization sources for mass spectrometry. Anal Bioanal Chem 2024; 416:2057-2063. [PMID: 37930374 DOI: 10.1007/s00216-023-05022-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2023] [Revised: 10/07/2023] [Accepted: 10/23/2023] [Indexed: 11/07/2023]
Abstract
Ambient ionization mass spectrometry (AIMS) has been developing explosively since its first debut. The ionization process was hence able to be achieved under atmospheric pressure, facilitating on-site field analysis in a variety of areas, such as clinical diagnosis, metabolic phenotyping, and surface analysis. As part of the ambitious goal of making MS a general device that can be used in everyday life, lots of efforts have been paid to miniaturize the ionization source. This review discusses avant-garde sources that could be entirely hand-held without any accessories. The structure and applications of the devices are described in detail as well. They could be expediently used in real-time and on-site analysis, presenting a great future potential for the routinizing of MS.
Collapse
Affiliation(s)
- Jinghan Fan
- Beijing National Laboratory for Molecular Sciences, Key Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry, Chinese Academy of Sciences, Beijing, 100190, China
- University of Chinese Academy of Sciences, Beijing, 100049, China
| | - Wenbo Ma
- State Key Laboratory of High-Efficiency Utilization of Coal and Green Chemical Engineering, College of Chemistry and Chemical Engineering, Ningxia University, Yinchuan, 750021, China
| | - Yile Yu
- Beijing National Laboratory for Molecular Sciences, Key Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry, Chinese Academy of Sciences, Beijing, 100190, China
- University of Chinese Academy of Sciences, Beijing, 100049, China
| | - Yuze Li
- State Key Laboratory of High-Efficiency Utilization of Coal and Green Chemical Engineering, College of Chemistry and Chemical Engineering, Ningxia University, Yinchuan, 750021, China.
| | - Zongxiu Nie
- Beijing National Laboratory for Molecular Sciences, Key Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry, Chinese Academy of Sciences, Beijing, 100190, China.
- University of Chinese Academy of Sciences, Beijing, 100049, China.
- State Key Laboratory of High-Efficiency Utilization of Coal and Green Chemical Engineering, College of Chemistry and Chemical Engineering, Ningxia University, Yinchuan, 750021, China.
| |
Collapse
|
3
|
Huang K, Zeng H, Li X, Li X, Pan Y, Gao Y. Arc-Induced Electrospray Ionization Mass Spectrometry. Anal Chem 2024; 96:317-324. [PMID: 38154037 DOI: 10.1021/acs.analchem.3c04125] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2023]
Abstract
Arc-induced electrospray ionization mass spectrometry (AESI-MS) was developed during which alternating current electrospray is simply achieved through the arc plasma. The AESI source exploits the arc's temperature and charge properties to generate aerosols consisting of charged microdroplets. The electrospray region, in which organic molecules are contained within microdroplets, partially overlaps with the arc plasma region. Guided by the electric field, these molecules undergo ionization, yielding ionic target analytes. AESI represents a soft ionization method that combines the mechanisms of atmospheric pressure chemical ionization and electrospray ionization, facilitating the ionization of analytes with wide ranging polarities. The precisely targeted spraying area enhances ion entry into the mass analyzer, thereby enabling excellent ionization efficiency. The AESI source exhibits several notable advantages over the electrospray ionization source, including an elevated but comparable level of active species concentrations and types, simplified mass spectra for direct amino acid analysis, high salt tolerance, versatile analysis of compounds with varying polarities, and reliable quantitative analysis of amino acids in complex matrices. Overall, AESI broadens the methodologies employed to generate microdroplets, providing a technological and scientific framework for creating distinctive electrospray ionization techniques.
Collapse
Affiliation(s)
- Kaineng Huang
- College of Chemistry and Materials Science, Sichuan Normal University, Chengdu, Sichuan 610068, P. R. China
| | - Hui Zeng
- College of Chemistry and Materials Science, Sichuan Normal University, Chengdu, Sichuan 610068, P. R. China
| | - Xingyue Li
- College of Chemistry and Materials Science, Sichuan Normal University, Chengdu, Sichuan 610068, P. R. China
| | - Xiaoting Li
- College of Chemistry and Materials Science, Sichuan Normal University, Chengdu, Sichuan 610068, P. R. China
| | - Yuanjiang Pan
- Department of Chemistry, Zhejiang University, Hangzhou, Zhejiang310027, P. R. China
| | - Yuanji Gao
- College of Chemistry and Materials Science, Sichuan Normal University, Chengdu, Sichuan 610068, P. R. China
| |
Collapse
|
4
|
Wevers D, Ramautar R, Clark C, Hankemeier T, Ali A. Opportunities and challenges for sample preparation and enrichment in mass spectrometry for single-cell metabolomics. Electrophoresis 2023; 44:2000-2024. [PMID: 37667867 DOI: 10.1002/elps.202300105] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2023] [Revised: 08/08/2023] [Accepted: 08/19/2023] [Indexed: 09/06/2023]
Abstract
Single-cell heterogeneity in metabolism, drug resistance and disease type poses the need for analytical techniques for single-cell analysis. As the metabolome provides the closest view of the status quo in the cell, studying the metabolome at single-cell resolution may unravel said heterogeneity. A challenge in single-cell metabolome analysis is that metabolites cannot be amplified, so one needs to deal with picolitre volumes and a wide range of analyte concentrations. Due to high sensitivity and resolution, MS is preferred in single-cell metabolomics. Large numbers of cells need to be analysed for proper statistics; this requires high-throughput analysis, and hence automation of the analytical workflow. Significant advances in (micro)sampling methods, CE and ion mobility spectrometry have been made, some of which have been applied in high-throughput analyses. Microfluidics has enabled an automation of cell picking and metabolite extraction; image recognition has enabled automated cell identification. Many techniques have been used for data analysis, varying from conventional techniques to novel combinations of advanced chemometric approaches. Steps have been set in making data more findable, accessible, interoperable and reusable, but significant opportunities for improvement remain. Herein, advances in single-cell analysis workflows and data analysis are discussed, and recommendations are made based on the experimental goal.
Collapse
Affiliation(s)
- Dirk Wevers
- Wageningen University and Research, Wageningen, The Netherlands
- Metabolomics and Analytics Centre, Leiden Academic Centre for Drug Research, Leiden, The Netherlands
| | - Rawi Ramautar
- Metabolomics and Analytics Centre, Leiden Academic Centre for Drug Research, Leiden, The Netherlands
| | - Charlie Clark
- Metabolomics and Analytics Centre, Leiden Academic Centre for Drug Research, Leiden, The Netherlands
| | - Thomas Hankemeier
- Metabolomics and Analytics Centre, Leiden Academic Centre for Drug Research, Leiden, The Netherlands
| | - Ahmed Ali
- Metabolomics and Analytics Centre, Leiden Academic Centre for Drug Research, Leiden, The Netherlands
| |
Collapse
|
5
|
Dou Q, Liu W, Xiang P, Zhao J. Quantitative Analysis of Three Synthetic Cannabinoids MDMB-4en-PINACA, ADB-BUTINACA, and ADB-4en-PINACA by Thermal-Assisted Carbon Fiber Ionization Mass Spectrometry. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2023; 34:2316-2322. [PMID: 37641897 DOI: 10.1021/jasms.3c00229] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/31/2023]
Abstract
Recently, synthetic cannabinoids (SCs) have emerged as new psychoactive substances (NPS) and have been frequently added to e-liquids, leading to their abuse. In order to detect SCs in e-liquids quickly and accurately, a thermal-assisted carbon fiber ionization mass spectrometry technique has been developed. The introduction of a heat source helps to reduce the matrix effects. The results indicate that the ratio of the slope of the matrix curve (e-liquids matrix) and the standard curve (methanol solution) for SCs analysis is close to 1, indicating a minimized matrix effect of this method. Furthermore, this method exhibits good quantitative ability when applied to real samples. It does not require sample pretreatment and is sensitive enough to directly quantify SCs in e-liquids. Our method is characterized by the ability to achieve rapid and direct quantitative analysis with minimized matrix effects. It provides a rapid and simple method for analyzing SCs in e-liquids.
Collapse
Affiliation(s)
- Quanlu Dou
- Department of Forensic Toxicology, Shanghai Key Laboratory of Forensic Medicine, Shanghai Forensic Service Platform, Academy of Forensic Science, Shanghai 200063, China
- School of Pharmacy, Yantai University, Yantai 264005, China
| | - Wanhui Liu
- School of Pharmacy, Yantai University, Yantai 264005, China
| | - Ping Xiang
- Department of Forensic Toxicology, Shanghai Key Laboratory of Forensic Medicine, Shanghai Forensic Service Platform, Academy of Forensic Science, Shanghai 200063, China
| | - Junbo Zhao
- Department of Forensic Toxicology, Shanghai Key Laboratory of Forensic Medicine, Shanghai Forensic Service Platform, Academy of Forensic Science, Shanghai 200063, China
| |
Collapse
|
6
|
Guo X, Li J, Bai H, Ma Q. Rapid on-site detection of persistent organic pollutants using multiwalled carbon nanotube-modified paper spray ionization and a miniature mass spectrometer. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2023; 37 Suppl 1:e9509. [PMID: 36945892 DOI: 10.1002/rcm.9509] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/02/2023] [Revised: 03/12/2023] [Accepted: 03/17/2023] [Indexed: 06/18/2023]
Abstract
RATIONALE Rapid on-site detection of persistent organic pollutants (POP) is highly desirable for environmental protection. METHODS Herein, a rapid on-site analytical workflow was developed for the investigation of polycyclic aromatic hydrocarbons and perfluorinated compounds using multiwalled carbon nanotube-modified paper spray ionization (PSI) coupled with a miniature ion trap mass spectrometer. Critical parameters regarding PSI and miniature mass spectrometry analysis were optimized. RESULTS The analytical performance of the developed method was evaluated under optimized conditions, obtaining a short analysis duration of less than 1 min, sufficient linearity with correlation coefficients greater than 0.99, acceptable recovery rates of 93.1%-105.8% with relative standard deviations of between 3.5% and 10.3%, and reasonable sensitivity with limits of detection and quantitation of 2-200 and 5-500 μg/L, respectively. CONCLUSIONS Considering these aspects, it was concluded that the present approach demonstrated a promising solution for rapid on-site detection of emerging POPs.
Collapse
Affiliation(s)
- Xiangyu Guo
- Key Laboratory of Consumer Product Quality Safety Inspection and Risk Assessment for State Market Regulation, Chinese Academy of Inspection and Quarantine, Beijing Economic-Technological Development Area, Beijing, China
| | - Junfang Li
- Key Laboratory of Consumer Product Quality Safety Inspection and Risk Assessment for State Market Regulation, Chinese Academy of Inspection and Quarantine, Beijing Economic-Technological Development Area, Beijing, China
| | - Hua Bai
- Key Laboratory of Consumer Product Quality Safety Inspection and Risk Assessment for State Market Regulation, Chinese Academy of Inspection and Quarantine, Beijing Economic-Technological Development Area, Beijing, China
| | - Qiang Ma
- Key Laboratory of Consumer Product Quality Safety Inspection and Risk Assessment for State Market Regulation, Chinese Academy of Inspection and Quarantine, Beijing Economic-Technological Development Area, Beijing, China
| |
Collapse
|
7
|
Wang S, Yang C, Zhao J, Li C, Fan X. Rapid and Direct Assessment of Asphalt Volatile Organic Compound Emission Based on Carbon Fiber Ionization Mass Spectrometry. ACS OMEGA 2023; 8:12968-12979. [PMID: 37065020 PMCID: PMC10099131 DOI: 10.1021/acsomega.3c00163] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/10/2023] [Accepted: 03/17/2023] [Indexed: 06/19/2023]
Abstract
Due to the complicacy of asphalt fumes, the analytical methods for investigating volatile organic compounds (VOCs) are very limited. In this study, a direct and real-time analysis method based on carbon fiber ionization mass spectrometry (CFI-MS), an ambient mass spectrometric technique, was established and successfully applied in the analysis of asphalt VOCs. The asphalt VOCs can be directly detected in the open atmosphere without the collection step of asphalt fumes, and the mass spectra of one asphalt sample can be obtained in a few seconds in both positive and negative ion modes. By investigating the mass spectral changes of asphalt fumes at different heating temperatures ranging from 50 to 200 °C, the temperature factor of asphalt fume emission was demonstrated in this work. The research results demonstrate that the complexity of asphalt fumes is positively related to the applied temperature. Moreover, the VOCs of saturates, aromatics, resins, and asphaltenes fractions were also analyzed by the direct analysis method. The result shows that aromatics contribute most to the emission of VOCs. In addition, the obtained mass spectra combined with the principal component analysis method show the great potential to quickly screen VOC inhibitors of asphalt materials.
Collapse
Affiliation(s)
- Shanshan Wang
- College
of Science, Chang’an University, Xi’an, Shaanxi 710064, China
| | - Chenchen Yang
- Shaanxi
Coal Chemical Industry Technology Research Institute Co., Ltd., Xi’an, Shaanxi 710064, China
| | - Junteng Zhao
- College
of Future Transportation, Chang’an
University, Xi’an, Shaanxi 710064, China
| | - Chenyao Li
- College
of Future Transportation, Chang’an
University, Xi’an, Shaanxi 710064, China
| | - Xinhao Fan
- College
of Civil Engineering, Chang’an University, Xi’an, Shaanxi 710064, China
| |
Collapse
|
8
|
Wen TL, Bai JH, Bao MM, Qin Y, Su Y, Guo YL. Ultrasonic sample introduction combined with flame assisted thermal ionization: Pretreatment-free direct mass spectrometry analysis for fraction collecting tubes of preparative liquid chromatography. Talanta 2023; 259:124508. [PMID: 37043878 DOI: 10.1016/j.talanta.2023.124508] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2023] [Revised: 03/18/2023] [Accepted: 03/30/2023] [Indexed: 04/14/2023]
Abstract
Ultrasonic sample introduction combined with flame assisted thermal ionization mass spectrometry (USI-FATI-MS) was developed to monitor the fractions of preparative liquid chromatography. Recently, ultrasound-based sample introduction techniques have achieved great advance in the field of high-throughput analysis. However, it is still a challenge to directly apply these existing techniques to the analysis of macro volume samples (mL level). In this work, ultrasonic sample introduction combined with flame assisted thermal ionization was used for pretreatment-free direct mass spectrometry analysis of micro to macro volume samples (μL-mL level). Utilizing this unique design of ultrasonic sample introduction, liquid sample in the container can be quickly atomized to the gas phase without contact. Then, due to the flame assisted thermal ionization source, desolvation and ionization of the sample droplets will occur immediately. USI-FATI-MS has shown excellent sensitivity, repeatability and great compatibility to solvents and compounds with a wide range of polarity. As a proof of concept, USI-FATI-MS has been applied for rapid monitoring and identification of purified synthetic and natural products in fractions.
Collapse
Affiliation(s)
- Tian-Lun Wen
- Institute of Interdisciplinary Integrative Medicine Research, Shanghai University of Traditional Chinese Medicine, Shanghai, 201203, China; National Center for Organic Mass Spectrometry in Shanghai, Shanghai Institute of Organic Chemistry, Chinese Academy of Sciences, 345 Lingling Road, Shanghai, 200032, China
| | - Jia-Hui Bai
- National Center for Organic Mass Spectrometry in Shanghai, Shanghai Institute of Organic Chemistry, Chinese Academy of Sciences, 345 Lingling Road, Shanghai, 200032, China
| | - Ming-Mai Bao
- National Center for Organic Mass Spectrometry in Shanghai, Shanghai Institute of Organic Chemistry, Chinese Academy of Sciences, 345 Lingling Road, Shanghai, 200032, China
| | - Yong Qin
- Institute of Interdisciplinary Integrative Medicine Research, Shanghai University of Traditional Chinese Medicine, Shanghai, 201203, China
| | - Yue Su
- Institute of Interdisciplinary Integrative Medicine Research, Shanghai University of Traditional Chinese Medicine, Shanghai, 201203, China.
| | - Yin-Long Guo
- National Center for Organic Mass Spectrometry in Shanghai, Shanghai Institute of Organic Chemistry, Chinese Academy of Sciences, 345 Lingling Road, Shanghai, 200032, China.
| |
Collapse
|
9
|
Wang Z, Shang HB, Cui M, Ma B, Li D, Jin D, Dong M. Use of tandem carbon microfiber columns for on-line fractionation strategy of reducing ion suppression effects in electrospray ionization-mass spectrometry. J Chromatogr A 2022; 1685:463641. [PMID: 36403517 DOI: 10.1016/j.chroma.2022.463641] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2022] [Revised: 11/05/2022] [Accepted: 11/05/2022] [Indexed: 11/09/2022]
Abstract
As we all know, the complexity and diversity of complex sample are confronting with challenge of high-sensitive mass spectrometry analysis, especially direct mass spectrometry. The work proposed a two-dimensional carbon microfiber fractionation (2DμCFs) system for the reduction of ion suppression effects in electrospray ionization mass spectrometry (ESI-MS). The 2DμCFs system can on-line fractionated the complex sample into strong-polar, medium-polar and weak-polar fractions for sequential MS analysis. Direct analysis brings about the strong ion suppression effect up to 85%, but the fractionated analysis of 2DμCFs system can distinctly reduce the ion suppression effect to less than 43%, even close to none. And the fractionated analysis not only decrease the number of analytes of direct analysis, but also narrows down the polarity range of analytes within the droplets of ESI, contributing to the homogeneous distribution to reduce the ion suppression effect. As an example, the 2DμCFs system coupled with tandem mass spectrometry (MS/MS) was applied for fractionated analysis of Radix Puerariae extract in 4.5 min. Compared with direct MS/MS, the 2DμCFs-MS/MS shows the lower ion suppression and the more ionic species (m/z). In addition, and most of ionic species detected by the 2DμCFs-MS/MS, are the same as those by HPLC MS/MS. Furthermore, the 2DμCFs-MS/MS exhibit the good analysis repeatability of real sample with the RSDs less than 10.32% (intra-day), 7.12% (inter-day) and 14.28% (inter-batch of CFs and ACFs). The carbon fibers (CFs) and active carbon fibers (ACFs) columns, as the key parts, are conducive to achieve on-line fractionation of compounds based on the difference of polarity. The 2DμCFs system has the merits of on-line, speediness, low-pressure and recycle. More importantly, such fast and high-throughput method is advantageous for comprehensive screening of complex samples in drug, clinical, environment and plant.
Collapse
|
10
|
Wang S, Bai J, Wang K, Guo Y. Carbon fiber paper spray ionization mass spectrometry. Anal Chim Acta 2022; 1232:340477. [DOI: 10.1016/j.aca.2022.340477] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2022] [Revised: 09/27/2022] [Accepted: 09/29/2022] [Indexed: 11/01/2022]
|
11
|
Luo S, Zhao Z, Wu Q, Wang Y, Lu H. Porous Graphitic Carbon-Based Imprint Mass Spectrometry Imaging with an Ambient Liquid Extraction Technique for Enhancing Coverage of Glycerolipids and Sphingolipids in Brain Tissue. Anal Chem 2022; 94:13753-13761. [PMID: 36173256 DOI: 10.1021/acs.analchem.2c01991] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Localization of lipidomes and tracking their spatial changes by mass spectrometry imaging (MSI) is critical for the mechanism studies on living process, disease, and therapeutic treatment. However, due to the strong ion suppression in complex biotissue, the imaging coverage for lipids with low polarity or low abundances, such as glycerolipids and sphingolipids, is usually limited. To address this issue, we utilized a porous graphitic carbon (PGC) material to imprint brain tissue sections for selective enrichment of neutral lipids with polar phospholipids removed. Then, the tissue imprint was scanned for desorption by the ambient liquid extraction MSI system. It was found that on the PGC surface, hydrophobic interaction dominates in protic solvents, and polar interaction dominates in aprotic solvents. Accordingly, methanol was selected as the spray solvent for tissue imprinting, and 75% acetonitrile-methanol was selected as the desorption solvent for the ambient liquid extraction MSI system. The results showed that glycerides had high recoveries after the imprinting-desorption process (recovery ∼ 70%) with phospholipids eliminated (recovery < 7%). To increase the transferring efficiencies of lipids from tissue onto PGC, electrospray was used for solvent application during imprinting, and the signals of diglycerides (DGs) in the imprint MSI of brain tissue increased by 2-3 times as compared to those via air spray. Finally, the new imprint MSI approach was applied to the imaging of the rat cerebellum and was compared with direct tissue MSI. The results showed that with imprint MSI, the coverage of DGs, sphingomyelins (SMs), and ceramides was enhanced by 4-5-fold (32 vs 6, 4 vs 1, and 5 vs 0). The ion images showed that with imprint MSI, higher signal intensities and clearer spatial distribution of DGs and SMs were obtained without interference from phosphatidylcholine signals compared with tissue MSI. This new method provides a complementary approach for traditional MSI to address the issues in imaging poorly ionizable or low-abundance lipids.
Collapse
Affiliation(s)
- Shifen Luo
- College of Chemistry and Chemical Engineering, Central South University, Hunan, Changsha 410083, P. R. China
| | - Zhihao Zhao
- College of Chemistry and Chemical Engineering, Central South University, Hunan, Changsha 410083, P. R. China
| | - Qian Wu
- College of Chemistry and Chemical Engineering, Central South University, Hunan, Changsha 410083, P. R. China
| | - Yang Wang
- Laboratory of Ethnopharmacology, Institute of Integrated Traditional Chinese and Western Medicine, Xiangya Hospital, Central South University, Hunan, Changsha 410008, P. R. China
| | - Hongmei Lu
- College of Chemistry and Chemical Engineering, Central South University, Hunan, Changsha 410083, P. R. China
| |
Collapse
|
12
|
Using Solid-Phase Microextraction Coupled with Reactive Carbon Fiber Ionization-Mass Spectrometry for the Detection of Aflatoxin B1 from Complex Samples. SEPARATIONS 2022. [DOI: 10.3390/separations9080199] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Aflatoxin B1 (AFB1) is a common mycotoxin present in agricultural and food products. Therefore, rapid screening methods must be developed for AFB1 detection with high sensitivity and good selectivity. In this study, we developed an analytical method based on the combination of solid-phase microextraction (SPME) with carbon fiber ionization (CFI)-mass spectrometry (MS) to detect the presence of trace AFB1 from complex samples. A pencil lead (type 2B, length: ~2.5 cm) with a sharp end (diameter: ~150 μm) was used as the SPME fiber and the ionization emitter in CFI-MS analysis. Owing to the graphite structure of the pencil lead, AFB1 can be trapped on the pencil lead through π–π interactions. After adsorbing AFB1, the pencil lead was directly introduced in a pipette tip (length: ~0.7 cm; tip inner diameter: ~0.6 mm), placed close (~1 mm) to the inlet of the mass spectrometer, and applied with a high voltage (−4.5 kV) for in situ AFB1 elution and CFI-MS analysis. A direct electric contact on the SPME-CFI setup was not required. Followed by the introduction of an elution solvent (10 μL) (acetonitrile/ethanol/deionized water, 2:2:1 (v/v/v)) to the pipette tip, electrospray ionization was generated from the elution solvent containing AFB1 for CFI-MS analysis. A reactive SPME-CFI-MS strategy was employed to further identify AFB1 and improve elution capacity using our approach. Butylamine was added to the elution solvent, which was then introduced to the pipette tip inserted with the SPME fiber. Butylamine-derivatized AFB1 was readily generated and appeared in the resultant SPME-CFI mass spectrum. The lowest detectable concentration against AFB1 using our approach was ~1.25 nM. Our method can distinguish AFB1 from AFG1 in a mixture and can be used for the detection of trace AFB1 in complex peanut extract samples.
Collapse
|
13
|
Kong R, Li L, Liu W, Xiang P, Zhao J. Rapid characterization of drugs in a single hair using thermal desorption ionization mass spectrometry. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2022; 14:806-812. [PMID: 35138309 DOI: 10.1039/d1ay01908b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Hair remains the most common type of physical evidence found in most crime scenes. However, the amount of hair found at a crime scene is limited and analysis of drugs in hair by gas chromatography mass spectrometry (GC-MS) or liquid chromatography tandem mass spectrometry (LC-MS/MS) is laborious and time-consuming. In this study, a rapid and simple method is developed using thermal desorption ionization mass spectrometry (TDI-MS) to analyze drugs directly in a single hair. A single hair is put onto a heated metal ceramic heater (MCH) and then a high voltage direct current and solvent are applied to the single hair. The drugs in the hair are thermally desorbed and ionized, and subsequently transferred to the MS inlet and detected. A typical hair analysis can be completed in a few minutes. This novel technique provides a new orientation for forensic scientists to study drugs in a single hair that is found at a crime scene, on a suspect, or on a victim.
Collapse
Affiliation(s)
- Ran Kong
- Department of Forensic Toxicology, Shanghai Key Laboratory of Forensic Medicine, Shanghai Forensic Service Platform, Academy of Forensic Science, Shanghai, China.
- School of Pharmacy, Yantai University, Yantai, China
| | - Le Li
- Department of Forensic Toxicology, Shanghai Key Laboratory of Forensic Medicine, Shanghai Forensic Service Platform, Academy of Forensic Science, Shanghai, China.
- School of Pharmacy, Yantai University, Yantai, China
| | - Wanhui Liu
- School of Pharmacy, Yantai University, Yantai, China
| | - Ping Xiang
- Department of Forensic Toxicology, Shanghai Key Laboratory of Forensic Medicine, Shanghai Forensic Service Platform, Academy of Forensic Science, Shanghai, China.
| | - Junbo Zhao
- Department of Forensic Toxicology, Shanghai Key Laboratory of Forensic Medicine, Shanghai Forensic Service Platform, Academy of Forensic Science, Shanghai, China.
| |
Collapse
|
14
|
Lu Y, Cao Y, Zhang L, Lv Y, Zhang Y, Su Y, Guo Y. Online Quaternized Derivatization Mapping and Glycerides Profiling of Cancer Tissues by Laser Ablation Carbon Fiber Ionization Mass Spectrometry. Anal Chem 2022; 94:3756-3761. [PMID: 35191670 DOI: 10.1021/acs.analchem.1c04926] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
Mass spectrometry imaging has become a hot research field owing to its ability to reflect the distribution of multiple metabolites in tissue. However, not all kinds of metabolites have great ionization efficiency in mass spectrometry imaging. The mass signals of low polar metabolites like monoglycerides and diglycerides may be seriously suppressed. Many strategies have been proposed to fix the problem, such as on-tissue derivatization and online derivatization. Also, some challenges were encountered when implementing these approaches. Herein, a platform coupled online quaternized derivatization and laser ablation carbon fiber ionization mass spectrometry imaging has been developed. The mass signals of monoglycerides and diglycerides were drastically increased in the platform, and high-quality mass images of these metabolites could be acquired readily. In the platform, metabolites were first desorbed by a laser and then reacted online with a derivatization reagent transmitted by carbon fiber ionization, which also undertook the postionization of derivatization products. Pyridine acted as the main derivatization reagent to target metabolites with hydroxyl groups. Remarkably, the derivatization reaction proceeded rapidly without any catalyst owing to the high energy provided by the laser. The mass images of eight monoglycerides and 21 diglycerides were achieved after applying the platform into human ovarian cancer tissues. Notably, a higher mass intensity of these glycerides was captured in cancerous tissues than in para-cancerous tissues, which might infer aberrations in glyceride metabolisms of cancerous tissues.
Collapse
Affiliation(s)
- Yingjie Lu
- Institute of Interdisciplinary Integrative Medicine Research, Shanghai University of Traditional Chinese Medicine, 1200 Cailun Road, Shanghai 201203, P. R. China
| | - Yuqi Cao
- State Key Laboratory of Organometallic Chemistry and National Center for Organic Mass Spectrometry in Shanghai, Shanghai Institute of Organic Chemistry, Chinese Academy of Sciences, Shanghai 200032, P. R. China
| | - Li Zhang
- State Key Laboratory of Organometallic Chemistry and National Center for Organic Mass Spectrometry in Shanghai, Shanghai Institute of Organic Chemistry, Chinese Academy of Sciences, Shanghai 200032, P. R. China
| | - Yuanyuan Lv
- Department of Gynaecology and Obstetrics, The First Affiliated Hospital of Wannan Medical College, Wuhu 241000, P. R. China
| | - Ying Zhang
- Department of Gynaecology and Obstetrics, The First Affiliated Hospital of Wannan Medical College, Wuhu 241000, P. R. China
| | - Yue Su
- Institute of Interdisciplinary Integrative Medicine Research, Shanghai University of Traditional Chinese Medicine, 1200 Cailun Road, Shanghai 201203, P. R. China
| | - Yinlong Guo
- State Key Laboratory of Organometallic Chemistry and National Center for Organic Mass Spectrometry in Shanghai, Shanghai Institute of Organic Chemistry, Chinese Academy of Sciences, Shanghai 200032, P. R. China
| |
Collapse
|
15
|
Sun J, Yin Y, Li W, Jin O, Na N. CHEMICAL REACTION MONITORING BY AMBIENT MASS SPECTROMETRY. MASS SPECTROMETRY REVIEWS 2022; 41:70-99. [PMID: 33259644 DOI: 10.1002/mas.21668] [Citation(s) in RCA: 19] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/06/2020] [Revised: 10/16/2020] [Accepted: 10/22/2020] [Indexed: 06/12/2023]
Abstract
Chemical reactions conducted in different media (liquid phase, gas phase, or surface) drive developments of versatile techniques for the detection of intermediates and prediction of reasonable reaction pathways. Without sample pretreatment, ambient mass spectrometry (AMS) has been applied to obtain structural information of reactive molecules that differ in polarity and molecular weight. Commercial ion sources (e.g., electrospray ionization, atmospheric pressure chemical ionization, and direct analysis in real-time) have been reported to monitor substrates and products by offline reaction examination. While the interception or characterization of reactive intermediates with short lifetime are still limited by the offline modes. Notably, online ionization technologies, with high tolerance to salt, buffer, and pH, can achieve direct sampling and ionization of on-going reactions conducted in different media (e.g., liquid phase, gas phase, or surface). Therefore, short-lived intermediates could be captured at unprecedented timescales, and the reaction dynamics could be studied for mechanism examinations without sample pretreatments. In this review, via various AMS methods, chemical reaction monitoring and mechanism elucidation for different classifications of reactions have been reviewed. The developments and advances of common ionization methods for offline reaction monitoring will also be highlighted.
Collapse
Affiliation(s)
- Jianghui Sun
- Key Laboratory of Radiopharmaceuticals Ministry of Education, College of Chemistry, Beijing Normal University, Beijing, People's Republic of China
| | - Yiyan Yin
- Key Laboratory of Radiopharmaceuticals Ministry of Education, College of Chemistry, Beijing Normal University, Beijing, People's Republic of China
| | - Weixiang Li
- Key Laboratory of Radiopharmaceuticals Ministry of Education, College of Chemistry, Beijing Normal University, Beijing, People's Republic of China
| | - Ouyang Jin
- Key Laboratory of Radiopharmaceuticals Ministry of Education, College of Chemistry, Beijing Normal University, Beijing, People's Republic of China
| | - Na Na
- Key Laboratory of Radiopharmaceuticals Ministry of Education, College of Chemistry, Beijing Normal University, Beijing, People's Republic of China
| |
Collapse
|
16
|
Zhao J, Yan H, Shi Y, Sheng B, Xiang P. Rapid Characterization of Drugs in Biological Fluid and Seized Material Using Thermal-Assisted Carbon Fiber Ionization Mass Spectrometry. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2021; 32:969-976. [PMID: 33779186 DOI: 10.1021/jasms.0c00472] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Developing a rapid, simple, and sensitive method to analyze drugs is critical to forensic research study because of the widespread occurrence of the matrix effect. Herein, we develop a method using thermal-assisted carbon fiber ionization mass spectrometry that can be used to directly analyze drugs in biological fluid. The key feature of this technique is that the biological samples such as urine and blood can be achieved online as precipitated protein on the carbon fiber tip and thermally desorbed by the metal ceramics heater, which can reduce the matrix effects and improve the sensitivity. Analytes including raw urine, blood, oral fluid, drink, tobacco tar, drug tablets, and paper cards can be rapidly identified and analyzed within a few minutes regardless of their physical variations. Due to its simplicity and noninvasive analysis, this method can be used for drugged driving analysis and to achieve point-of-care drug testing in clinical and forensic chemistry.
Collapse
Affiliation(s)
- Junbo Zhao
- Department of Forensic Toxicology, Shanghai Key Laboratory of Forensic Medicine, Shanghai Forensic Service Platform, Academy of Forensic Science, Shanghai 200063, China
| | - Hui Yan
- Department of Forensic Toxicology, Shanghai Key Laboratory of Forensic Medicine, Shanghai Forensic Service Platform, Academy of Forensic Science, Shanghai 200063, China
| | - Yan Shi
- Department of Forensic Toxicology, Shanghai Key Laboratory of Forensic Medicine, Shanghai Forensic Service Platform, Academy of Forensic Science, Shanghai 200063, China
| | - Baohua Sheng
- Department of Forensic Toxicology, Shanghai Key Laboratory of Forensic Medicine, Shanghai Forensic Service Platform, Academy of Forensic Science, Shanghai 200063, China
| | - Ping Xiang
- Department of Forensic Toxicology, Shanghai Key Laboratory of Forensic Medicine, Shanghai Forensic Service Platform, Academy of Forensic Science, Shanghai 200063, China
| |
Collapse
|
17
|
Chen L, Ghiasvand A, Rodriguez ES, Innis PC, Paull B. Applications of nanomaterials in ambient ionization mass spectrometry. Trends Analyt Chem 2021. [DOI: 10.1016/j.trac.2021.116202] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|
18
|
Wang Z, Cao Y, Lu Y, Zhang F, Su Y, Guo Y. Ultrasonic extraction and nebulization in real-time coupled with carbon fiber ionization mass spectrometry for rapid screening of the synthetic drugs adulterated into herbal products. Anal Chim Acta 2020; 1136:62-71. [DOI: 10.1016/j.aca.2020.08.045] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2020] [Accepted: 08/24/2020] [Indexed: 12/14/2022]
|
19
|
Zhu SZ, Zhang L, Zhang J, Guo YL. Arc Plasma-Based Dissociation Device: Fingerprinting Mass Spectrometric Analysis Realized at Atmospheric Condition. Anal Chem 2020; 92:14633-14639. [DOI: 10.1021/acs.analchem.0c03127] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Affiliation(s)
- Su-zhen Zhu
- State Key Laboratory of Organometallic Chemistry and National Center for Organic Mass Spectrometry in Shanghai, Center for Excellence in Molecular Synthesis, Shanghai Institute of Organic Chemistry, University of Chinese Academy of Sciences, Chinese Academy of Sciences, 345 Lingling Road, Shanghai 200032, China
| | - Li Zhang
- State Key Laboratory of Organometallic Chemistry and National Center for Organic Mass Spectrometry in Shanghai, Center for Excellence in Molecular Synthesis, Shanghai Institute of Organic Chemistry, University of Chinese Academy of Sciences, Chinese Academy of Sciences, 345 Lingling Road, Shanghai 200032, China
| | - Jing Zhang
- State Key Laboratory of Organometallic Chemistry and National Center for Organic Mass Spectrometry in Shanghai, Center for Excellence in Molecular Synthesis, Shanghai Institute of Organic Chemistry, University of Chinese Academy of Sciences, Chinese Academy of Sciences, 345 Lingling Road, Shanghai 200032, China
| | - Yin-long Guo
- State Key Laboratory of Organometallic Chemistry and National Center for Organic Mass Spectrometry in Shanghai, Center for Excellence in Molecular Synthesis, Shanghai Institute of Organic Chemistry, University of Chinese Academy of Sciences, Chinese Academy of Sciences, 345 Lingling Road, Shanghai 200032, China
| |
Collapse
|
20
|
Filho JFA, Dos Santos NA, Borges KB, Lacerda V, Pelição FS, Romão W. Fiber spray ionization mass spectrometry in forensic chemistry: A screening of drugs of abuse and direct determination of cocaine in urine. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2020; 34 Suppl 3:e8747. [PMID: 32056289 DOI: 10.1002/rcm.8747] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/03/2019] [Revised: 01/30/2020] [Accepted: 02/06/2020] [Indexed: 06/10/2023]
Abstract
RATIONALE Ambient mass spectrometry techniques are much required in forensic chemistry to evaluate evidence with low analytical interference, high confidence, and accuracy. However, traditional methodologies, such as paper spray ionization, have been shown to present low sensitivity in the analysis of illicit drugs from biological matrices. METHODS Fiber spray ionization mass spectrometry (FSI-MS) was developed using a capillary polypropylene (PP) hollow fiber. Seized samples of drugs, i.e. a tablet, blotter paper, hashish, and cocaine powder, were analyzed. Cocaine was quantified from whole urine by dipping the fiber directly into solution. FSI-MS was tested for the analysis of a sample of urine obtained from a drug abuse suspect. RESULTS The FSI(+) analysis showed the detection of different types of synthetic drugs in tablet and blotter paper samples, e.g. amphetamine, cathinones, phenethylamines, and opioids, while pure cocaine and different types of coca alkaloids were identified from cocaine powder with good sensitivity and high mass accuracy. The hashish analysis by FSI(-) revealed signals of cannabinoids, cannabinoid acids, and cannabinoid derivatives, detected mainly as [M - H]- ions or chlorine adducts [M + Cl]- . The quantification of cocaine in whole urine showed good sensitivity and precision with limits of detection and quantification of 5.16 and 17.21 ng/mL, respectively, linearity above 0.999, and relative standard deviation below 2.71%. The evaluation of seized sample of urine showed the detection of cocaine with relative ion intensity greater than 36%, as well as the metabolites benzoylecgonine and cocaethylene with a relative intensity of 1.4% and 6%, respectively. CONCLUSIONS The developed FSI-MS method has the potential to be applied to forensic sample evaluation as well as to determine illicit drugs from biological matrices in toxicological analysis. The use of a capillary PP fiber has advantages as an extractor agent and ionizing substrate, and also the feature of it being dipped directly into the sample, thus preserving the integrity of the sample, which makes this a very promising ambient mass spectrometry method and relevant to forensic chemistry.
Collapse
Affiliation(s)
- João Francisco Allochio Filho
- Laboratório de Petroleômica e Química Forense, Departamento de Química, Universidade Federal do Espírito Santo, Vitória, ES, 29075-910, Brazil
- Instituto Federal do Espírito Santo, São Mateus, ES, 29932-540, Brazil
- Instituto Nacional de Ciência e Tecnologia Forense (INCT Forense), Brazil
| | - Nayara A Dos Santos
- Laboratório de Petroleômica e Química Forense, Departamento de Química, Universidade Federal do Espírito Santo, Vitória, ES, 29075-910, Brazil
- Instituto Nacional de Ciência e Tecnologia Forense (INCT Forense), Brazil
| | - Keyller Bastos Borges
- Departamento de Ciências Naturais, Universidade Federal de São João del-Rei, São João del-Rei, MG, 36301-160, Brazil
| | - Valdemar Lacerda
- Laboratório de Petroleômica e Química Forense, Departamento de Química, Universidade Federal do Espírito Santo, Vitória, ES, 29075-910, Brazil
| | - Fabrício Souza Pelição
- Departamento Médico Legal, Polícia Civil do Espírito Santo (PC-ES), Vitória, ES, 29045-402, Brazil
| | - Wanderson Romão
- Laboratório de Petroleômica e Química Forense, Departamento de Química, Universidade Federal do Espírito Santo, Vitória, ES, 29075-910, Brazil
- Instituto Nacional de Ciência e Tecnologia Forense (INCT Forense), Brazil
- Instituto Federal do Espírito Santo, Vila Velha, ES, 29106-010, Brazil
| |
Collapse
|
21
|
Selective and sensitive analysis by reactive easy ambient sonic-spray ionization: Synergistic combination of non-polar spray solvent and dicationic ionic liquid. Talanta 2020; 215:120929. [DOI: 10.1016/j.talanta.2020.120929] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2020] [Revised: 03/09/2020] [Accepted: 03/12/2020] [Indexed: 12/30/2022]
|
22
|
Reactive carbon fiber ionization-mass spectrometry for characterization of unsaturated hydrocarbons from plant aroma. Anal Bioanal Chem 2020; 412:5489-5497. [PMID: 32583215 DOI: 10.1007/s00216-020-02769-4] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2020] [Revised: 05/17/2020] [Accepted: 06/12/2020] [Indexed: 12/30/2022]
Abstract
Carbon fiber ionization (CFI)-mass spectrometry (MS) is an ambient technique that can be used to detect samples in gas, liquid, and solid forms simply by using a piece of carbon fiber as the ionization emitter. Reactive MS can be performed to selectively detect target analytes by conducting fast reactions during ionization. Most ambient ionization MS techniques used to monitor chemical reactions are limited to liquid-phase reactions. Herein, we develop reactive CFI-MS to be a suitable tool for monitoring of reaction products derived from volatile unsaturated hydrocarbons in the gas phase. Hydroamination is a fast reaction that can form a carbon-nitrogen bond through the addition of an amine to unsaturated hydrocarbons. In this study, reactive CFI-MS was used to selectively characterize aroma molecules, which are unsaturated hydrocarbons derived from plants, through hydroamination. A piece of carbon fiber was placed close (~ 1 mm) to the inlet of the mass spectrometer and deposited with dried methylamine. The sample in either liquid or solid form was placed underneath the carbon fiber. The volatiles derived from the sample reacted with amine on the carbon fiber were simultaneously determined once the mass spectrometer was switched on. For proof of concept, ethylene glycol dimethacrylate, which has double bonds and is highly volatile, was initially selected as the model sample to demonstrate the feasibility of using reactive CFI-MS to detect its hydroamination derivative. Banana, garlic, and ginger, which possess aroma molecules with unsaturated hydrocarbons, were selected as real-world samples. Graphical abstract.
Collapse
|
23
|
Cao YQ, Zhang L, Zhang J, Guo YL. Single-Cell On-Probe Derivatization-Noncontact Nanocarbon Fiber Ionization: Unraveling Cellular Heterogeneity of Fatty Alcohol and Sterol Metabolites. Anal Chem 2020; 92:8378-8385. [PMID: 32420735 DOI: 10.1021/acs.analchem.0c00954] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
Currently in single-cell mass spectrometry, the analysis of low-abundance cell metabolites such as fatty alcohols and sterols remains a challenge. In most research studies, single-cell samples are analyzed directly after sampling. However, this workflow may exclude many effective sample pretreatment methods such as derivatization for the improvement of detection sensitivity for specific cell metabolites in a single-cell sample. Metabolites in low abundance in a cell may not be detected. Herein on-probe derivatization coupled with noncontact nanocarbon fiber ionization is proposed for sensitive fatty alcohol and sterol metabolite analysis at the single-cell level. Fatty alcohol and sterol metabolites were rapidly quaternized by the single-cell on-probe derivatization method. The reaction products were directly ionized with no postreaction processing. Furthermore, a new ionization source for noncontact nanocarbon fiber ionization was developed to show good compatibility with dichloromethane, a low-polarity solvent used in on-probe derivatization. The quaternized fatty alcohols and sterols exhibited evidently enhanced ionization efficiency in mass spectra. In applications of the developed method, seven kinds of even-numbered-carbon fatty alcohols (C12-C22) and five kinds of sterols were detected in single L-02 and HepG2 cells. Then the L-02 and HepG2 cells were readily discriminated through principal component analysis. Additionally, a rough quantitative analysis of the detected fatty alcohols and sterols in single cells was performed. The mass intensities of fatty alcohols show a significant difference between L-02 and HepG2 cells while those of sterols remain stable.
Collapse
Affiliation(s)
- Yu-Qi Cao
- State Key Laboratory of Organometallic Chemistry and National Center for Organic Mass Spectrometry in Shanghai, Center for Excellence in Molecular Synthesis, Shanghai Institute of Organic Chemistry, University of Chinese Academy of Sciences, Chinese Academy of Sciences, 345 Lingling Road, Shanghai, 200032, China
| | - Li Zhang
- State Key Laboratory of Organometallic Chemistry and National Center for Organic Mass Spectrometry in Shanghai, Center for Excellence in Molecular Synthesis, Shanghai Institute of Organic Chemistry, University of Chinese Academy of Sciences, Chinese Academy of Sciences, 345 Lingling Road, Shanghai, 200032, China
| | - Jing Zhang
- State Key Laboratory of Organometallic Chemistry and National Center for Organic Mass Spectrometry in Shanghai, Center for Excellence in Molecular Synthesis, Shanghai Institute of Organic Chemistry, University of Chinese Academy of Sciences, Chinese Academy of Sciences, 345 Lingling Road, Shanghai, 200032, China
| | - Yin-Long Guo
- State Key Laboratory of Organometallic Chemistry and National Center for Organic Mass Spectrometry in Shanghai, Center for Excellence in Molecular Synthesis, Shanghai Institute of Organic Chemistry, University of Chinese Academy of Sciences, Chinese Academy of Sciences, 345 Lingling Road, Shanghai, 200032, China
| |
Collapse
|
24
|
Guo X, Bai H, Ma X, Li J, Ren Y, Ouyang Z, Ma Q. Online coupling of an electrochemically fabricated solid-phase microextraction probe and a miniature mass spectrometer for enrichment and analysis of chemical contaminants in infant drinks. Anal Chim Acta 2020; 1098:66-74. [DOI: 10.1016/j.aca.2019.11.021] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2019] [Revised: 11/06/2019] [Accepted: 11/11/2019] [Indexed: 12/15/2022]
|
25
|
Li Y, Cao Y, Guo Y. Recent Advances in Atmospheric Ionization Mass Spectrometry: Developments and Applications. CHINESE J CHEM 2019. [DOI: 10.1002/cjoc.201900359] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Affiliation(s)
- Yuling Li
- State Key Laboratory of Organometallic Chemistry, National Center for Organic Mass Spectrometry in ShanghaiShanghai Institute of Organic Chemistry, Chinese Academy of Sciences Shanghai 200032 China
| | - Yuqi Cao
- State Key Laboratory of Organometallic Chemistry, National Center for Organic Mass Spectrometry in ShanghaiShanghai Institute of Organic Chemistry, Chinese Academy of Sciences Shanghai 200032 China
| | - Yinlong Guo
- State Key Laboratory of Organometallic Chemistry, National Center for Organic Mass Spectrometry in ShanghaiShanghai Institute of Organic Chemistry, Chinese Academy of Sciences Shanghai 200032 China
| |
Collapse
|
26
|
Direct analysis of volatile components from intact jujube by carbon fiber ionization mass spectrometry. BMC Chem 2019; 13:125. [PMID: 31696162 PMCID: PMC6823938 DOI: 10.1186/s13065-019-0641-4] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2019] [Accepted: 10/15/2019] [Indexed: 11/18/2022] Open
Abstract
In situ analysis of odor is an important approach to connect odor with chemical composition. However, it is difficult to conduct a rapid direct analysis of the odor sample because of low analyte concentration and sampling. To achieve the direct analysis, a carbon fiber ionization mass spectrometry (CFI-MS) method has been developed and applied to measure volatile components releasing from intact jujube. To build the CFI source, a 2.0-cm long carbon fiber bundle was integrated on the pin of a commercial corona discharge needle by mean of a 1.3-cm long stainless hollow tube. Odor sample driven by N2 gas can be directly introduced to the carbon fiber bundle to complete the ionization of analytes. Acetic acid, ethyl acetate, ethyl caproate, octyl acetate, and damascone present in jujube were selected to evaluate the performance of the CFI-MS method on quantitative analysis of the gaseous sample. Good lineary was obtained (R2 ≥ 0.9946) between 5.0 and 500.0 ng/L with limits of detection (LOD) ranging from 0.5 to 1.5 ng/L. Recoveries of five volatile compounds for the spiked jujube samples were between 94.36 and 106.74% with relative standard deviations (RSDs) less than 7.27% (n = 5). Jujube of different varieties can be distinguished by principal components analysis based on the analytical results of volatile compounds. The developed method demonstrated obvious advantages such as simplicity, high throughput, good sensitivity and wide range of applicability, which will be an alternative way for in situ analysis of the odor sample.![]()
Collapse
|
27
|
Molecularly imprinted graphite spray ionization-ion mobility spectrometry: application to trace analysis of the pesticide propoxur. Mikrochim Acta 2019; 186:396. [PMID: 31161360 DOI: 10.1007/s00604-019-3467-9] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2019] [Accepted: 04/29/2019] [Indexed: 10/26/2022]
Abstract
A porous graphite sheet modified by a molecularly imprinted polymer (MIP) was directly used as the spray ionization source for ion mobility spectrometry (IMS). Therefore, it was possible to selectively analyze samples extracted by the molecularly imprinted polymer. This obviates the need for the steps of elution, solvent evaporation, dissolution and injection. To prepare the sheet, the graphite surface was first modified by electrodeposition of a molecularly imprinted polypyrrole film. This polypyrrole film was fabricated in a three-electrode electrochemical system using cyclic voltammetry. The electropolymerization of the graphite sheet was carried out with LiClO4 as a supporting electrolyte in the reaction solution. The effects of the amount of monomer, the level of template concentrations, and the time of polymerization on the extraction efficiency of the MIP film were evaluated. The extraction conditions including extraction time, the extraction temperature, the pH values, the salt concentrations, and the stirring rate were also studied. Methanol was selected as the most suitable solvent for both desorption and ionization which occur simultaneously. The pesticide propoxur (acting as a test compound) was extracted from water samples and directly analyzed using IMS. The analytical parameters (working range: 1.0 to 250 ng·mL-1; detection limit: 0.3 ng·mL-1) indicated that the direct coupling of MIP and IMS has a great potential in terms of reproducibility, and speed of the analysis, while maintaining acceptable sensitivity. Graphical abstract Schematic presentation of molecularly imprinted graphite spray ionization coupled with ion mobility spectrometry (IMS) for rapid/selective extraction and ionization: Application to the pre-concentration of propoxur prior to its quantification by IMS.
Collapse
|
28
|
Rahman M, Wu D, Chingin K. Direct Analysis of Aqueous Solutions and Untreated Biological Samples Using Nanoelectrospray Ionization Mass Spectrometry with Pipette Tip in Series with High-Ohmic Resistor as Ion Source. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2019; 30:814-823. [PMID: 30834507 DOI: 10.1007/s13361-019-02142-5] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/19/2018] [Revised: 12/28/2018] [Accepted: 01/21/2019] [Indexed: 06/09/2023]
Abstract
Commercially available disposable plastic pipette tip with the inner diameter of ca. 120 μm in series with a high-ohmic resistor (10 GΩ) was adapted as a low-cost alternative ion source for high-throughput nanoelectrospray mass spectrometry (nESI-MS) analysis of a variety of samples, especially aqueous solutions, without sample pretreatment. The use of high-ohmic resistor enabled the formation of stable electrospray of aqueous solutions at ambient conditions. In addition, corona discharge was avoided even with a high voltage applied. Quantitative analysis of vitamin B in water was successfully conducted by tip-ESI. The results exhibited a good linearity (R ˃ 0.9983), a low detection limit (0.25 ng/mL), and a wide dynamic response range (0.25-1000 ng/mL). Our study revealed that tip-ESI not only performed equally well to capillary nESI in terms of flow rate (˂ 100 nL/min), signal sensitivity, and sample consumption, but also offered a number of additional advantages, including better signal duration, tolerance to high analyte concentration (> 100 μg/mL) and high ionizing voltage (up to 6 kV), and obviation of tip clogging and corona discharge. High compatibility of tip-ESI with various kinds of samples (aqueous, viscous, solid, or bulk biological samples) makes it a promising tool for direct MS analysis.
Collapse
Affiliation(s)
- Matiur Rahman
- Jiangxi Key Laboratory for Mass Spectrometry and Instrumentation, East China University of Technology, Nanchang, 330013, People's Republic of China
| | - Debo Wu
- Jiangxi Key Laboratory for Mass Spectrometry and Instrumentation, East China University of Technology, Nanchang, 330013, People's Republic of China.
| | - Konstantin Chingin
- Jiangxi Key Laboratory for Mass Spectrometry and Instrumentation, East China University of Technology, Nanchang, 330013, People's Republic of China
| |
Collapse
|
29
|
GUO XY, HUANG XM, ZHAI JF, BAI H, LI XX, MA XX, MA Q. Research Advances in Ambient Ionization and Miniature Mass Spectrometry. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY 2019. [DOI: 10.1016/s1872-2040(19)61145-x] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|
30
|
Huang Z, Yao YN, Li W, Hu B. Analytical properties of electrospray ionization mass spectrometry with solid substrates and nonpolar solvents. Anal Chim Acta 2019; 1050:105-112. [DOI: 10.1016/j.aca.2018.10.064] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2018] [Revised: 10/25/2018] [Accepted: 10/26/2018] [Indexed: 01/03/2023]
|
31
|
Carbon fiber ionization mass spectrometry coupled with solid phase microextraction for analysis of Benzo[a]pyrene. Anal Chim Acta 2019; 1049:133-140. [DOI: 10.1016/j.aca.2018.10.037] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2018] [Revised: 10/12/2018] [Accepted: 10/16/2018] [Indexed: 11/21/2022]
|
32
|
Zhang Q, Liu X, Li Z, Su Y, Guo Y. Rapid quantitative analysis with low matrix effects of capsaicin in various samples by thermal desorption carbon fiber ionization mass spectrometry. Anal Chim Acta 2019; 1048:115-122. [DOI: 10.1016/j.aca.2018.10.016] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2018] [Revised: 09/28/2018] [Accepted: 10/07/2018] [Indexed: 12/20/2022]
|
33
|
Wu ML, Wu YC, Chen YC. Detection of pesticide residues on intact tomatoes by carbon fiber ionization mass spectrometry. Anal Bioanal Chem 2019; 411:1095-1105. [PMID: 30613840 DOI: 10.1007/s00216-018-1539-z] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2018] [Revised: 11/29/2018] [Accepted: 12/05/2018] [Indexed: 01/18/2023]
Abstract
Trace and toxic pesticide residues may still remain on crops after harvest. Thus, maximum residual levels (MRLs) of pesticides on crops have been regulated. To determine whether the remaining pesticide residue level is below MRL, time-consuming sample pretreatment is needed prior to analysis of crop samples by suitable analytical tools. By elimination of sample pretreatment steps, a high-throughput method can be developed to determine the presence of pesticide residues directly on intact crops. Carbon fiber ionization mass spectrometry (CFI-MS) is effective in determining analytes with different polarities in solid, liquid, and vapor phases in open air. Moreover, the vapor derived from solid or liquid samples possessing high vapor pressure can be readily detected by CFI-MS. The setup of CFI-MS is straightforward. A carbon fiber (diameter of ~ 10 μm and length of ~ 1 cm) is placed close (~ 1 mm) to the inlet of the mass spectrometer applied with a high voltage (- 4.5 kV). No direct electrical contact applied on the carbon fiber is required. When placing the sample with certain vapor pressure underneath the carbon fiber, analyte ions derived from the sample can be readily detected by the mass spectrometer. Given that most pesticides possess a certain vapor pressure (~ 1.33 × 10-5-~ 1.33 × 10-4 Pa), we herein develop a qualitative and quantitative analysis method to determine pesticide residues on intact fruits such as tomato based on CFI-MS without requiring any sample pretreatment. Atrazine, ametryn, carbofuran, chlorpyrifos, isoprocarb, and methomyl were selected as model samples. Low limits of detection (at nM range) were achieved for the model pesticides using the current approach. Moreover, we demonstrated that the precision and accuracy of quantitative analysis of ~ 5% and ~ 2%, respectively, could be achieved using this approach. Graphical Abstract ᅟ.
Collapse
Affiliation(s)
- Min-Li Wu
- Department of Applied Chemistry, National Chiao Tung University, 1001 Ta Hseuch Road, Hsinchu, 300, Taiwan
| | - Yi-Cheng Wu
- Department of Applied Chemistry, National Chiao Tung University, 1001 Ta Hseuch Road, Hsinchu, 300, Taiwan
| | - Yu-Chie Chen
- Department of Applied Chemistry, National Chiao Tung University, 1001 Ta Hseuch Road, Hsinchu, 300, Taiwan.
| |
Collapse
|
34
|
ZHANG XL, ZHANG H, WANG XC, HUANG KK, WANG D, CHEN HW. Advances in Ambient Ionization for Mass Spectrometry. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY 2018. [DOI: 10.1016/s1872-2040(18)61122-3] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
35
|
Zargar T, Jafari MT, Khayamian T. Porous graphite sheet spray ionization ion mobility spectrometry. JOURNAL OF MASS SPECTROMETRY : JMS 2018; 53:1135-1142. [PMID: 30221428 DOI: 10.1002/jms.4289] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/30/2018] [Revised: 08/18/2018] [Accepted: 09/10/2018] [Indexed: 06/08/2023]
Abstract
In this work, a porous graphite sheet is introduced as the substrate in a spray ionization source for ion mobility spectrometry (PGSI-IMS) for the first time. This ionization source has some important advantages in comparison with the hollow needle, which is conventionally used in electrospray ionization. In order to prepare the hydrophilic surface needed to load samples on a graphite substrate, the graphite sheet was treated with hot sulfuric acid solution for 2 hours. Some parameters affecting the ionization efficiency were studied, and the optimized conditions were found to be 3.5-kV graphite voltage, 24-μL methanol flow rate, 500 mL min-1 the gas flow rate, and graphite sheet with a 60° tip angle and 3-mm distance from the counter electrode. Finally, analyses of some test compounds (imipramine, diclofenac, codeine, morphine, and ethion) were conducted to evaluate the capability of the new ionization source in the positive and negative modes. The satisfactory results proved the capability of the graphite sheet spray ionization, to be conveniently used for routine analysis of chemical compounds by IMS.
Collapse
Affiliation(s)
- Tahereh Zargar
- Department of Chemistry, Isfahan University of Technology, Isfahan, Iran
| | - Mohammad T Jafari
- Department of Chemistry, Isfahan University of Technology, Isfahan, Iran
| | - Taghi Khayamian
- Department of Chemistry, Isfahan University of Technology, Isfahan, Iran
| |
Collapse
|
36
|
Liu XP, Wang HY, Dong GQ, Li ZQ, Guo YL. Fast Eruption Desorption Ionization for Mass Spectrometric Analysis. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2018; 29:1319-1322. [PMID: 29679286 DOI: 10.1007/s13361-018-1962-6] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/07/2018] [Revised: 04/02/2018] [Accepted: 04/02/2018] [Indexed: 06/08/2023]
Abstract
Fast eruption desorption ionization (FEDI) technique was developed for simple, rapid, and sensitive analysis of various compounds. The FEDI allows three analytical modes each with the unique characteristic. The results demonstrated that non-assisted eruption was suitable for stable and volatile compounds, energetic material (EM)-assisted for nonvolatile molecules especially metal compounds, and solvent-assisted eruption for fragile molecules. High-quality mass spectra with intact ions of analytes were obtained in positive and negative ion modes. Graphical Abstract ᅟ.
Collapse
Affiliation(s)
- Xiao-Pan Liu
- State Key Laboratory of Organometallic Chemistry and National Center for Organic Mass Spectrometry in Shanghai, Center for Excellence in Molecular Synthesis, Shanghai Institute of Organic Chemistry, University of Chinese Academy of Sciences, Chinese Academy of Sciences, 345 Lingling Road, Shanghai, 20032, China
| | - Hao-Yang Wang
- State Key Laboratory of Organometallic Chemistry and National Center for Organic Mass Spectrometry in Shanghai, Center for Excellence in Molecular Synthesis, Shanghai Institute of Organic Chemistry, University of Chinese Academy of Sciences, Chinese Academy of Sciences, 345 Lingling Road, Shanghai, 20032, China.
| | - Guo-Qing Dong
- State Key Laboratory of Organometallic Chemistry and National Center for Organic Mass Spectrometry in Shanghai, Center for Excellence in Molecular Synthesis, Shanghai Institute of Organic Chemistry, University of Chinese Academy of Sciences, Chinese Academy of Sciences, 345 Lingling Road, Shanghai, 20032, China
| | - Zhong-Quan Li
- State Key Laboratory of Organometallic Chemistry and National Center for Organic Mass Spectrometry in Shanghai, Center for Excellence in Molecular Synthesis, Shanghai Institute of Organic Chemistry, University of Chinese Academy of Sciences, Chinese Academy of Sciences, 345 Lingling Road, Shanghai, 20032, China
| | - Yin-Long Guo
- State Key Laboratory of Organometallic Chemistry and National Center for Organic Mass Spectrometry in Shanghai, Center for Excellence in Molecular Synthesis, Shanghai Institute of Organic Chemistry, University of Chinese Academy of Sciences, Chinese Academy of Sciences, 345 Lingling Road, Shanghai, 20032, China.
| |
Collapse
|
37
|
Wu ML, Chen TY, Chen YC, Chen YC. Carbon Fiber Ionization Mass Spectrometry for the Analysis of Analytes in Vapor, Liquid, and Solid Phases. Anal Chem 2017; 89:13458-13465. [DOI: 10.1021/acs.analchem.7b03736] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Affiliation(s)
- Min-Li Wu
- Department of Applied Chemistry, National Chiao Tung University, Hsinchu 300, Taiwan
| | - Te-Yu Chen
- Department of Applied Chemistry, National Chiao Tung University, Hsinchu 300, Taiwan
| | - Yen-Chun Chen
- Department of Applied Chemistry, National Chiao Tung University, Hsinchu 300, Taiwan
| | - Yu-Chie Chen
- Department of Applied Chemistry, National Chiao Tung University, Hsinchu 300, Taiwan
| |
Collapse
|
38
|
Nahan KS, Alvarez N, Shanov V, Vonderheide A. Carbon Nanotube Fiber Ionization Mass Spectrometry: A Fundamental Study of a Multi-Walled Carbon Nanotube Functionalized Corona Discharge Pin for Polycyclic Aromatic Hydrocarbons Analysis. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2017; 28:2408-2413. [PMID: 28884369 DOI: 10.1007/s13361-017-1774-0] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/02/2017] [Revised: 07/16/2017] [Accepted: 07/27/2017] [Indexed: 06/07/2023]
Abstract
Mass spectrometry continues to tackle many complicated tasks, and ongoing research seeks to simplify its instrumentation as well as sampling. The desorption electrospray ionization (DESI) source was the first ambient ionization source to function without extensive gas requirements and chromatography. Electrospray techniques generally have low efficiency for ionization of nonpolar analytes and some researchers have resorted to methods such as direct analysis in real time (DART) or desorption atmospheric pressure chemical ionization (DAPCI) for their analysis. In this work, a carbon nanotube fiber ionization (nanoCFI) source was developed and was found to be capable of solid phase microextraction (SPME) of nonpolar analytes as well as ionization and sampling similar to that of direct probe atmospheric pressure chemical ionization (DP-APCI). Conductivity and adsorption were maintained by utilizing a corona pin functionalized with a multi-walled carbon nanotube (MWCNT) thread. Quantitative work with the nanoCFI source with a designed corona discharge pin insert demonstrated linearity up to 0.97 (R2) of three target PAHs with phenanthrene internal standard. Graphical Abstract ᅟ.
Collapse
Affiliation(s)
- Keaton S Nahan
- Department of Chemistry, University of Cincinnati/Agilent Technologies Metallomics Center of the Americas, University of Cincinnati, Mail Location 0172, Cincinnati, OH, 45221, USA.
| | - Noe Alvarez
- Nanoworld Laboratories, Department of Biomedical, Chemical and Environmental Engineering, Engineering, College of Engineering and Applied Science, University of Cincinnati, Cincinnati, OH, 45221, USA
| | - Vesselin Shanov
- Nanoworld Laboratories, Department of Biomedical, Chemical and Environmental Engineering, Engineering, College of Engineering and Applied Science, University of Cincinnati, Cincinnati, OH, 45221, USA
| | - Anne Vonderheide
- Department of Chemistry, McMicken College of Arts and Sciences, University of Cincinnati, Cincinnati, OH, 45221, USA
| |
Collapse
|
39
|
Li X, Ma W, Li H, Ai W, Bai Y, Liu H. Sampling and analyte enrichment strategies for ambient mass spectrometry. Anal Bioanal Chem 2017; 410:715-724. [DOI: 10.1007/s00216-017-0658-2] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2017] [Revised: 09/03/2017] [Accepted: 09/19/2017] [Indexed: 12/29/2022]
|
40
|
Fu X, Liang H, Xia B, Huang C, Ji B, Zhou Y. Determination of Sulfonamides in Chicken Muscle by Pulsed Direct Current Electrospray Ionization Tandem Mass Spectrometry. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY 2017; 65:8256-8263. [PMID: 28854784 DOI: 10.1021/acs.jafc.7b03803] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
A simple and rapid approach for the simultaneous detection of trace amounts of six sulfonamides in chicken muscle was developed using pulsed direct current electrospray ionization tandem mass spectrometry (pulsed-dc ESI-MS/MS). The pretreatment of chicken muscle samples consisted of two steps: acetonitrile extraction and n-hexane delipidation. Sulfonamides do not need to be derivatized or chromatographed prior to pulsed-dc ESI-MS/MS. The factors affecting the performance of pulsed-dc ESI-MS/MS were studied. Under optimum conditions, the quantitative performance of pulsed-dc ESI-MS/MS was validated according to European Union Decision 2002/657/EC, and the sensitivity of pulsed-dc ESI-MS/MS was 3 times higher than that of ultrahigh-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). The limits of detection obtained by pulsed-dc ESI-MS/MS were in the range of 0.07-0.11 μg/kg. The proposed method was simple, rapid, and sensitive, and was successfully used for quantitation and rapid screening of sulfonamides in real chicken muscle samples.
Collapse
Affiliation(s)
- Xian Fu
- Chengdu Institute of Biology, Chinese Academy of Sciences , No. 93 South Keyuan Road, Gaoxin Distinct, Chengdu 610041, P. R. China
- University of Chinese Academy of Sciences , Beijing 100049, P. R. China
| | - Hengxing Liang
- Chengdu Institute for Food and Drug Control , Chengdu 610045, P. R. China
| | - Bing Xia
- Chengdu Institute of Biology, Chinese Academy of Sciences , No. 93 South Keyuan Road, Gaoxin Distinct, Chengdu 610041, P. R. China
| | - Chunyan Huang
- Chengdu Institute for Food and Drug Control , Chengdu 610045, P. R. China
| | - Baocheng Ji
- Chengdu Institute of Biology, Chinese Academy of Sciences , No. 93 South Keyuan Road, Gaoxin Distinct, Chengdu 610041, P. R. China
- University of Chinese Academy of Sciences , Beijing 100049, P. R. China
| | - Yan Zhou
- Chengdu Institute of Biology, Chinese Academy of Sciences , No. 93 South Keyuan Road, Gaoxin Distinct, Chengdu 610041, P. R. China
| |
Collapse
|
41
|
Affiliation(s)
- Patricia M Peacock
- First State IR, LLC , 118 Susan Drive, Hockessin, Delaware 19707, United States
| | - Wen-Jing Zhang
- Department of Chemistry, Wayne State University , 5101 Cass Avenue, Detroit, Michigan 48202, United States
| | - Sarah Trimpin
- Department of Chemistry, Wayne State University , 5101 Cass Avenue, Detroit, Michigan 48202, United States
| |
Collapse
|