1
|
Chen M, Zeng H, Luo F, Huang Y, Lin C, Wang J, Qiu B, Lin Z. Electrochemiluminescence Biosensor for Ascorbic Acid Based on Target Transformation of Cell-Free RNA Transcription System and Duplex-Specific Nuclease-Assisted Recycling Amplification. Anal Chem 2024; 96:17807-17813. [PMID: 39462859 DOI: 10.1021/acs.analchem.4c04206] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/29/2024]
Abstract
A cell-free RNA transcription system had been coupled with electrochemiluminescence (ECL) detection technology for the first time to develop an ascorbic acid (AA, acting as a model target) biosensor. The biosensor is composed of single-stranded DNA (ssDNA) sequences modified with alkynyl and azido groups, respectively, alongside an incomplete gene circuit framework. The addition of target AA and copper ions will cause the linkage of the two ssDNA sequences through a click chemistry reaction. This results in the subsequent reconstruction of a complete gene circuit. The reconstituted gene circuit, in conjunction with the T7 RNA polymerase, drives the transcription of substantial quantities of RNA. ssDNA labeled with ferrocene (Fc) (Fc-DNA) had been immobilized on a tris(2,2'-bipyridyl) ruthenium(II) chloride hexahydrate-doped SiO2 nanoparticle (Ru@SiO2 NPs) modified electrode first. The quenching effect of Fc on Ru@SiO2 causes the low ECL detected. The transcribed RNA sequence assisted double-stranded specific nuclease (DSN) to cut the ssDNA-Fc and the ECL of the system was enhanced. Optimal experimental conditions reveal that the ECL signal exhibits a linear correlation with the logarithmic concentration of AA, spanning a detection range from 100 nM to 1 mM, with a detection limit of 45 nM. This innovative methodology expands the utility of a cell-free RNA transcription system within the realm of biosensing applications.
Collapse
Affiliation(s)
- Ming Chen
- Ministry of Education Key Laboratory for Analytical Science of Food Safety and Biology, Fujian Provincial Key Laboratory of Analysis and Detection for Food Safety, College of Chemistry, Fuzhou University, Fuzhou, Fujian 350116, China
| | - Hongfu Zeng
- Department of Thoracic Oncology, Clinical Oncology School of Fujian Medical University, Fujian Cancer Hospital (Fujian Branch of Fudan University Shanghai Cancer Center), No. 420 Fuma Road, Fuzhou, Fujian 350014, China
| | - Fang Luo
- Ministry of Education Key Laboratory for Analytical Science of Food Safety and Biology, Fujian Provincial Key Laboratory of Analysis and Detection for Food Safety, College of Chemistry, Fuzhou University, Fuzhou, Fujian 350116, China
| | - Yunjian Huang
- Department of Thoracic Oncology, Clinical Oncology School of Fujian Medical University, Fujian Cancer Hospital (Fujian Branch of Fudan University Shanghai Cancer Center), No. 420 Fuma Road, Fuzhou, Fujian 350014, China
| | - Cuiying Lin
- Ministry of Education Key Laboratory for Analytical Science of Food Safety and Biology, Fujian Provincial Key Laboratory of Analysis and Detection for Food Safety, College of Chemistry, Fuzhou University, Fuzhou, Fujian 350116, China
| | - Jian Wang
- Ministry of Education Key Laboratory for Analytical Science of Food Safety and Biology, Fujian Provincial Key Laboratory of Analysis and Detection for Food Safety, College of Chemistry, Fuzhou University, Fuzhou, Fujian 350116, China
| | - Bin Qiu
- Ministry of Education Key Laboratory for Analytical Science of Food Safety and Biology, Fujian Provincial Key Laboratory of Analysis and Detection for Food Safety, College of Chemistry, Fuzhou University, Fuzhou, Fujian 350116, China
| | - Zhenyu Lin
- Ministry of Education Key Laboratory for Analytical Science of Food Safety and Biology, Fujian Provincial Key Laboratory of Analysis and Detection for Food Safety, College of Chemistry, Fuzhou University, Fuzhou, Fujian 350116, China
| |
Collapse
|
2
|
Bhatt A, Jain S, Navani NK. Rapid, Sensitive, and Specific Microbial Whole-Cell Biosensor for the Detection of Histamine: A Potential Food Toxin. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY 2024. [PMID: 39441673 DOI: 10.1021/acs.jafc.4c06315] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/25/2024]
Abstract
Histamine is a biogenic amine; its level indicates food quality, as elevated levels cause food poisoning. Therefore, monitoring food at each step during processing until it reaches the consumer is crucial, but current techniques are complicated and time-consuming. Here, we designed a Pseudomonas putida whole-cell biosensor using a histamine-responsive genetic element expressing a fluorescent protein in the presence of the cognate target. We improved the performance of the proposed biosensor by optimizing the chassis, genetic regulatory element, and reporter gene. A sensitive and rapid biosensor variant was obtained with a limit of detection (LOD) of 0.39 ppm, manifesting a linear response (R2 = 0.98) from 0.28 to 18 ppm in 90 min. The biosensor showed minimal cross-reactivity with other biogenic amines and amino acids prevalent in food, making it highly specific. The biosensor effectively quantified histamine in spiked fish, prawn, and wine samples with a satisfactory recovery. Additionally, a colorimetric sensor variant PAlacZ was developed enabling histamine quantification in seafood via a smartphone application, with an LODgray of 0.23 ppm, exhibiting a linear response from 0 to 2.24 ppm. Overall, this study reports an efficient, specific, and highly sensitive biosensor with strong potential for the on-site detection of histamine, ensuring food safety.
Collapse
Affiliation(s)
- Ankita Bhatt
- Chemical Biology Lab, Department of Biosciences and Bioengineering, Indian Institute of Technology Roorkee, Roorkee, Uttarakhand 247667, India
| | - Shubham Jain
- Chemical Biology Lab, Department of Biosciences and Bioengineering, Indian Institute of Technology Roorkee, Roorkee, Uttarakhand 247667, India
| | - Naveen K Navani
- Chemical Biology Lab, Department of Biosciences and Bioengineering, Indian Institute of Technology Roorkee, Roorkee, Uttarakhand 247667, India
| |
Collapse
|
3
|
Li Q, Chen S, Wang H, Chang Q, Li Y, Li J. Decoding wheat contamination through self-assembled whole-cell biosensor combined with linear and non-linear machine learning algorithms. Biosens Bioelectron 2024; 267:116869. [PMID: 39447529 DOI: 10.1016/j.bios.2024.116869] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2024] [Revised: 09/22/2024] [Accepted: 10/20/2024] [Indexed: 10/26/2024]
Abstract
The contamination of mycotoxins is a serious problem around the world. It has detrimental effects on human beings and leads to tremendous economic loss. It is essential to develop a rapid and non-destructive method for contamination recognition particularly for early alarm. In this study, the whole-cell biosensor array was constructed and employed for rapid recognition of wheat contamination by combining with machine learning algorithms. Seven key VOCs were explored through univariate coupling to multivariate analysis of orthogonal partial least squares-discrimination analysis (OPLS-DA) models. The promoters of dnaK, katG, oxyR, soxS obtained from the stress-responsive of key VOCs were fused to the bacterial operon and fabricated on the whole-cell biosensor. The constructed whole-cell biosensor array was consisted with four kinds of sensors and 18 sensor unit. The bioluminescent intensity combined with linear machine learning algorithm of partial least squares discriminant analysis (PLS-DA) and non-linear algorithms of back propagating artificial neural network (BP-ANN) and least square support vector machine (LS-SVM) were employed to establish discrimination models for mold contamination especially for early warning. The Monte-Carlo strategy was performed to generate thirty subsets for modeling to give more reliable results. As a result, the whole-cell biosensor combined with non-linear algorithm of LS-SVM was practicable for detecting mold identification for wheat early-warning with the accuracy of 97.24%. Additionally, this study provides practical and effective methods not only for wheat quality guarantee and supervision but also for other foodstuffs.
Collapse
Affiliation(s)
- Qianqian Li
- Institute of Food Science and Technology, Chinese Academy of Agricultural Sciences, Key Laboratory of Agro-products Quality and Safety Control in Storage and Transport Process, Ministry of Agriculture and Rural Affairs, Beijing, 100093, PR China
| | - Shengfan Chen
- Institute of Food Science and Technology, Chinese Academy of Agricultural Sciences, Key Laboratory of Agro-products Quality and Safety Control in Storage and Transport Process, Ministry of Agriculture and Rural Affairs, Beijing, 100093, PR China
| | - Huawei Wang
- Institute of Food Science and Technology, Chinese Academy of Agricultural Sciences, Key Laboratory of Agro-products Quality and Safety Control in Storage and Transport Process, Ministry of Agriculture and Rural Affairs, Beijing, 100093, PR China
| | - Qiaoying Chang
- Agro-product Safety Research Center, Chinese Academy of Inspection and Quarantine, Beijing, 100176, PR China
| | - Yi Li
- Institute of Food Science and Technology, Chinese Academy of Agricultural Sciences, Key Laboratory of Agro-products Quality and Safety Control in Storage and Transport Process, Ministry of Agriculture and Rural Affairs, Beijing, 100093, PR China
| | - Jianxun Li
- Institute of Food Science and Technology, Chinese Academy of Agricultural Sciences, Key Laboratory of Agro-products Quality and Safety Control in Storage and Transport Process, Ministry of Agriculture and Rural Affairs, Beijing, 100093, PR China.
| |
Collapse
|
4
|
Liu Y, Zhou Z, Wu Y, Wang L, Cheng J, Zhu L, Dong Y, Zheng J, Xu W. Engineered transcription factor-binding diversed functional nucleic acid-based synthetic biosensor. Biotechnol Adv 2024; 77:108463. [PMID: 39374798 DOI: 10.1016/j.biotechadv.2024.108463] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2024] [Revised: 08/30/2024] [Accepted: 10/04/2024] [Indexed: 10/09/2024]
Abstract
Engineered transcription factors (eTFs) binding diversed functional nucleic acids (dFNAs), as innovative biorecognition systems, have gradually become indispensable core elements for building synthetic biosensors. They not only circumvent the limitations of the original TF-based biosensing technologies, but also inject new vitality into the field of synthetic biosensing. This review aims to provide the first comprehensive and systematic dissection of the eTF-dFNA synthetic biosensor concept. Firstly, the core principles and interaction mechanisms of eTF-dFNA biosensors are clarified. Next, we elaborate on the construction strategies of eTF-dFNA synthetic biosensors, detailing methods for the personalized customization of eTFs (irrational design, rational design, and semi-rational design) and dFNAs (SELEX, modifying and predicting), along with the exploration of strategies for the flexible selection of signal amplification and output modes. Furthermore, we discuss the exceptional performance and substantial advantages of eTF-dFNA synthetic biosensors, analyzing them from four perspectives: recognition domain, detection speed, sensitivity, and construction methodology. Building upon this analysis, we present their outstanding applications in point-of-care diagnostics, food-safety detection, environmental monitoring, and production control. Finally, we address the current limitations of eTF-dFNA synthetic biosensors candidly and envision the future direction of this technology, aiming to provide valuable insights for further research and applications in this burgeoning field.
Collapse
Affiliation(s)
- Yanger Liu
- Food Laboratory of Zhongyuan, Key Laboratory of Precision Nutrition and Food Quality, Department of Nutrition and Health, Ministry of Education, China Agricultural University, Beijing 100193, China; Key Laboratory of Veterinary Anatomy, College of Veterinary Medicine, China Agricultural University, Beijing 100193, China
| | - Ziying Zhou
- Food Laboratory of Zhongyuan, Key Laboratory of Precision Nutrition and Food Quality, Department of Nutrition and Health, Ministry of Education, China Agricultural University, Beijing 100193, China
| | - Yifan Wu
- Food Laboratory of Zhongyuan, Key Laboratory of Precision Nutrition and Food Quality, Department of Nutrition and Health, Ministry of Education, China Agricultural University, Beijing 100193, China
| | - Lei Wang
- Key Laboratory of Veterinary Anatomy, College of Veterinary Medicine, China Agricultural University, Beijing 100193, China
| | - Jiageng Cheng
- Food Laboratory of Zhongyuan, Key Laboratory of Precision Nutrition and Food Quality, Department of Nutrition and Health, Ministry of Education, China Agricultural University, Beijing 100193, China
| | - Longjiao Zhu
- Food Laboratory of Zhongyuan, Key Laboratory of Precision Nutrition and Food Quality, Department of Nutrition and Health, Ministry of Education, China Agricultural University, Beijing 100193, China; Key Laboratory of Geriatrics (Hepatobiliary Diseases), China General Technology Group, Beijing 100073, China.
| | - Yulan Dong
- Food Laboratory of Zhongyuan, Key Laboratory of Precision Nutrition and Food Quality, Department of Nutrition and Health, Ministry of Education, China Agricultural University, Beijing 100193, China; Key Laboratory of Veterinary Anatomy, College of Veterinary Medicine, China Agricultural University, Beijing 100193, China
| | - Jie Zheng
- School of Chemistry and Chemical Engineering, Chongqing University, Chongqing 400044, China.
| | - Wentao Xu
- Food Laboratory of Zhongyuan, Key Laboratory of Precision Nutrition and Food Quality, Department of Nutrition and Health, Ministry of Education, China Agricultural University, Beijing 100193, China; Key Laboratory of Geriatrics (Hepatobiliary Diseases), China General Technology Group, Beijing 100073, China.
| |
Collapse
|
5
|
Arik N, Elcin E, Tezcaner A, Oktem HA. Biosensing of arsenic by whole-cell bacterial bioreporter immobilized on polycaprolactone (PCL) electrospun fiber. ENVIRONMENTAL TECHNOLOGY 2024; 45:4874-4886. [PMID: 37965791 DOI: 10.1080/09593330.2023.2283405] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/24/2023] [Accepted: 09/19/2023] [Indexed: 11/16/2023]
Abstract
In recent years, heavy metals derived from several anthropogenic sources have both direct and indirect detrimental effects on the health of the environment and living organisms. Whole-cell bioreporters (WCBs) that can be used to monitor the levels of heavy metals in drinking and natural spring waters are important. In this study, whole-cell arsenic bacterial bioreporters were immobilized using polycaprolactone (PCL) electrospun fibers as the support material. The aim is to determine the properties of this immobilized bioreporter system by evaluating its performance in arsenic detection. Within the scope of the study, different growth media and fiber immobilization times were tested to determine the parameters affecting the fluorescent signals emitted by the immobilized bioreporter system in the presence of two dominant forms of arsenic, namely arsenite (As(III)) and arsenate (As(V)). In addition, the sensitivity, selectivity, response time, and shelf-life of the developed bioreporter system were evaluated. As far as the literature is concerned, this is the first study to investigate the potential of using PCL-electrospun fiber-immobilized fluorescent bacterial bioreporter for arsenic detection. This study will open new avenues in environmental arsenic monitoring.
Collapse
Affiliation(s)
- Nehir Arik
- Department of Molecular Biology and Genetics, Middle East Technical University, Ankara, Türkiye
| | - Evrim Elcin
- Department of Agricultural Biotechnology, Aydın Adnan Menderes University, Aydın, Türkiye
| | - Aysen Tezcaner
- Department of Engineering Sciences, Middle East Technical University, Ankara, Türkiye
- Center of Excellence in Biomaterials and Tissue Engineering (METU BIOMATEN), Ankara, Türkiye
| | - Huseyin A Oktem
- Department of Molecular Biology and Genetics, Middle East Technical University, Ankara, Türkiye
- Department of Biological Sciences, Middle East Technical University, Ankara, Türkiye
| |
Collapse
|
6
|
Joshi SHN, Jenkins C, Ulaeto D, Gorochowski TE. Accelerating Genetic Sensor Development, Scale-up, and Deployment Using Synthetic Biology. BIODESIGN RESEARCH 2024; 6:0037. [PMID: 38919711 PMCID: PMC11197468 DOI: 10.34133/bdr.0037] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2024] [Accepted: 04/23/2024] [Indexed: 06/27/2024] Open
Abstract
Living cells are exquisitely tuned to sense and respond to changes in their environment. Repurposing these systems to create engineered biosensors has seen growing interest in the field of synthetic biology and provides a foundation for many innovative applications spanning environmental monitoring to improved biobased production. In this review, we present a detailed overview of currently available biosensors and the methods that have supported their development, scale-up, and deployment. We focus on genetic sensors in living cells whose outputs affect gene expression. We find that emerging high-throughput experimental assays and evolutionary approaches combined with advanced bioinformatics and machine learning are establishing pipelines to produce genetic sensors for virtually any small molecule, protein, or nucleic acid. However, more complex sensing tasks based on classifying compositions of many stimuli and the reliable deployment of these systems into real-world settings remain challenges. We suggest that recent advances in our ability to precisely modify nonmodel organisms and the integration of proven control engineering principles (e.g., feedback) into the broader design of genetic sensing systems will be necessary to overcome these hurdles and realize the immense potential of the field.
Collapse
Affiliation(s)
| | - Christopher Jenkins
- CBR Division, Defence Science and Technology Laboratory, Porton Down, Wiltshire SP4 0JQ, UK
| | - David Ulaeto
- CBR Division, Defence Science and Technology Laboratory, Porton Down, Wiltshire SP4 0JQ, UK
| | - Thomas E. Gorochowski
- School of Biological Sciences, University of Bristol, Bristol BS8 1TQ, UK
- BrisEngBio,
School of Chemistry, University of Bristol, Bristol BS8 1TS, UK
| |
Collapse
|
7
|
Zhang J, Guo Y, Lin YR, Ma BC, Ge XR, Zhang WQ, Zhang NX, Yang SM, Hui CY. Detection of Cadmium in Human Biospecimens by a Cadmium-Selective Whole-Cell Biosensor Based on Deoxyviolacein. ACS Biomater Sci Eng 2024; 10:4046-4058. [PMID: 38722544 DOI: 10.1021/acsbiomaterials.3c01814] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/11/2024]
Abstract
Cadmium poses a severe health risk, impacting various bodily systems. Monitoring human exposure is vital. Urine and blood cadmium serve as critical biomarkers. However, current urine and blood cadmium detection methods are expensive and complex. Being cost-effective, user-friendly, and efficient, visual biosensing offers a promising complement to existing techniques. Therefore, we constructed a cadmium whole-cell biosensor using CadR10 and deoxyviolacein pigment in this study. We assessed the sensor for time-dose response, specific response to cadmium, sensitivity response to cadmium, and stability response to cadmium. The results showed that (1) the sensor had a preferred signal-to-noise ratio when the incubation time was 4 h; (2) the sensor showed excellent specificity for cadmium compared to the group 12 metals and lead; (3) the sensor was responsive to cadmium down to 1.53 nM under experimental conditions and had good linearity over a wide range from 1.53 nM to 100 μM with good linearity (R2 = 0.979); and (4) the sensor had good stability. Based on the excellent results of the performance tests, we developed a cost-effective, high-throughput method for detecting urinary and blood cadmium. Specifically, this was realized by adding the blood or urine samples into the culture system in a particular proportion. Then, the whole-cell biosensor was subjected to culture, n-butanol extraction, and microplate reading. The results showed that (1) at 20% urine addition ratio, the sensor had an excellent curvilinear relationship (R2 = 0.986) in the range of 3.05 nM to 100 μM, and the detection limit could reach 3.05 nM. (2) At a 10% blood addition ratio, the sensor had an excellent nonlinear relationship (R2 = 0.978) in the range of 0.097-50 μM, and the detection limit reached 0.195 μM. Overall, we developed a sensitive and wide-range method based on a whole-cell biosensor for the detection of cadmium in blood and urine, which has the advantages of being cost-effective, ease of operation, fast response, and low dependence on instrumentation and has the potential to be applied in the monitoring of cadmium exposure in humans as a complementary to the mainstream detection techniques.
Collapse
Affiliation(s)
- Juan Zhang
- Department of Epidemiology and Biostatistics, School of Public Health, Jilin University, Changchun 130021, Jilin, China
| | - Yan Guo
- Shenzhen Prevention and Treatment Center for Occupational Diseases, 2019 Buxin Road, Shenzhen 518020, China
| | - Yi-Ran Lin
- Shenzhen Prevention and Treatment Center for Occupational Diseases, 2019 Buxin Road, Shenzhen 518020, China
| | - Bing-Chan Ma
- School of Public Health, Tongji Medical College, Huazhong University of Science and Technology, 13 Hangkong Road, Wuhan 430030, China
| | - Xue-Ru Ge
- Department of Epidemiology and Biostatistics, School of Public Health, Jilin University, Changchun 130021, Jilin, China
| | - Wen-Qi Zhang
- Shenzhen Prevention and Treatment Center for Occupational Diseases, 2019 Buxin Road, Shenzhen 518020, China
| | - Nai-Xing Zhang
- Shenzhen Prevention and Treatment Center for Occupational Diseases, 2019 Buxin Road, Shenzhen 518020, China
| | - Shu-Man Yang
- Department of Epidemiology and Biostatistics, School of Public Health, Jilin University, Changchun 130021, Jilin, China
| | - Chang-Ye Hui
- Shenzhen Prevention and Treatment Center for Occupational Diseases, 2019 Buxin Road, Shenzhen 518020, China
| |
Collapse
|
8
|
Zevallos-Aliaga D, De Graeve S, Obando-Chávez P, Vaccari NA, Gao Y, Peeters T, Guerra DG. Highly Sensitive Whole-Cell Mercury Biosensors for Environmental Monitoring. BIOSENSORS 2024; 14:246. [PMID: 38785720 PMCID: PMC11117708 DOI: 10.3390/bios14050246] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/24/2024] [Revised: 04/27/2024] [Accepted: 04/30/2024] [Indexed: 05/25/2024]
Abstract
Whole-cell biosensors could serve as eco-friendly and cost-effective alternatives for detecting potentially toxic bioavailable heavy metals in aquatic environments. However, they often fail to meet practical requirements due to an insufficient limit of detection (LOD) and high background noise. In this study, we designed a synthetic genetic circuit specifically tailored for detecting ionic mercury, which we applied to environmental samples collected from artisanal gold mining sites in Peru. We developed two distinct versions of the biosensor, each utilizing a different reporter protein: a fluorescent biosensor (Mer-RFP) and a colorimetric biosensor (Mer-Blue). Mer-RFP enabled real-time monitoring of the culture's response to mercury samples using a plate reader, whereas Mer-Blue was analysed for colour accumulation at the endpoint using a specially designed, low-cost camera setup for harvested cell pellets. Both biosensors exhibited negligible baseline expression of their respective reporter proteins and responded specifically to HgBr2 in pure water. Mer-RFP demonstrated a linear detection range from 1 nM to 1 μM, whereas Mer-Blue showed a linear range from 2 nM to 125 nM. Our biosensors successfully detected a high concentration of ionic mercury in the reaction bucket where artisanal miners produce a mercury-gold amalgam. However, they did not detect ionic mercury in the water from active mining ponds, indicating a concentration lower than 3.2 nM Hg2+-a result consistent with chemical analysis quantitation. Furthermore, we discuss the potential of Mer-Blue as a practical and affordable monitoring tool, highlighting its stability, reliance on simple visual colorimetry, and the possibility of sensitivity expansion to organic mercury.
Collapse
Affiliation(s)
- Dahlin Zevallos-Aliaga
- Laboratorio de Moléculas Individuales, Laboratorios de Investigación y Desarrollo, Facultad de Ciencias e Ingeniería, Universidad Peruana Cayetano Heredia, Lima 15102, Peru; (D.Z.-A.); (P.O.-C.); (N.A.V.)
| | - Stijn De Graeve
- Open BioLab Brussels, Erasmushogeschool Brussel, Laarbeeklaan 121, B-1090 Jette, Belgium
| | - Pamela Obando-Chávez
- Laboratorio de Moléculas Individuales, Laboratorios de Investigación y Desarrollo, Facultad de Ciencias e Ingeniería, Universidad Peruana Cayetano Heredia, Lima 15102, Peru; (D.Z.-A.); (P.O.-C.); (N.A.V.)
| | - Nicolás A. Vaccari
- Laboratorio de Moléculas Individuales, Laboratorios de Investigación y Desarrollo, Facultad de Ciencias e Ingeniería, Universidad Peruana Cayetano Heredia, Lima 15102, Peru; (D.Z.-A.); (P.O.-C.); (N.A.V.)
| | - Yue Gao
- Archaeology, Environmental Changes and Geo-Chemistry (AMGC), Vrije Universiteit Brussel, Pleinlaan 2, B-1050 Brussels, Belgium;
| | - Tom Peeters
- Open BioLab Brussels, Erasmushogeschool Brussel, Laarbeeklaan 121, B-1090 Jette, Belgium
| | - Daniel G. Guerra
- Laboratorio de Moléculas Individuales, Laboratorios de Investigación y Desarrollo, Facultad de Ciencias e Ingeniería, Universidad Peruana Cayetano Heredia, Lima 15102, Peru; (D.Z.-A.); (P.O.-C.); (N.A.V.)
| |
Collapse
|
9
|
Free TJ, Talley JP, Hyer CD, Miller CJ, Griffitts JS, Bundy BC. Engineering the Signal Resolution of a Paper-Based Cell-Free Glutamine Biosensor with Genetic Engineering, Metabolic Engineering, and Process Optimization. SENSORS (BASEL, SWITZERLAND) 2024; 24:3073. [PMID: 38793927 PMCID: PMC11124800 DOI: 10.3390/s24103073] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/03/2024] [Revised: 05/03/2024] [Accepted: 05/10/2024] [Indexed: 05/26/2024]
Abstract
Specialized cancer treatments have the potential to exploit glutamine dependence to increase patient survival rates. Glutamine diagnostics capable of tracking a patient's response to treatment would enable a personalized treatment dosage to optimize the tradeoff between treatment success and dangerous side effects. Current clinical glutamine testing requires sophisticated and expensive lab-based tests, which are not broadly available on a frequent, individualized basis. To address the need for a low-cost, portable glutamine diagnostic, this work engineers a cell-free glutamine biosensor to overcome assay background and signal-to-noise limitations evident in previously reported studies. The findings from this work culminate in the development of a shelf-stable, paper-based, colorimetric glutamine test with a high signal strength and a high signal-to-background ratio for dramatically improved signal resolution. While the engineered glutamine test is important progress towards improving the management of cancer and other health conditions, this work also expands the assay development field of the promising cell-free biosensing platform, which can facilitate the low-cost detection of a broad variety of target molecules with high clinical value.
Collapse
Affiliation(s)
- Tyler J. Free
- Department of Chemical Engineering, Brigham Young University, Provo, UT 84602, USA
| | - Joseph P. Talley
- Department of Chemical Engineering, Brigham Young University, Provo, UT 84602, USA
| | - Chad D. Hyer
- Department of Chemical Engineering, Brigham Young University, Provo, UT 84602, USA
| | - Catherine J. Miller
- Department of Chemical Engineering, Brigham Young University, Provo, UT 84602, USA
| | - Joel S. Griffitts
- Department of Microbiology and Molecular Biology, Brigham Young University, Provo, UT 84602, USA
| | - Bradley C. Bundy
- Department of Chemical Engineering, Brigham Young University, Provo, UT 84602, USA
| |
Collapse
|
10
|
Buson F, Gao Y, Wang B. Genetic Parts and Enabling Tools for Biocircuit Design. ACS Synth Biol 2024; 13:697-713. [PMID: 38427821 DOI: 10.1021/acssynbio.3c00691] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/03/2024]
Abstract
Synthetic biology aims to engineer biological systems for customized tasks through the bottom-up assembly of fundamental building blocks, which requires high-quality libraries of reliable, modular, and standardized genetic parts. To establish sets of parts that work well together, synthetic biologists created standardized part libraries in which every component is analyzed in the same metrics and context. Here we present a state-of-the-art review of the currently available part libraries for designing biocircuits and their gene expression regulation paradigms at transcriptional, translational, and post-translational levels in Escherichia coli. We discuss the necessary facets to integrate these parts into complex devices and systems along with the current efforts to catalogue and standardize measurement data. To better display the range of available parts and to facilitate part selection in synthetic biology workflows, we established biopartsDB, a curated database of well-characterized and useful genetic part and device libraries with detailed quantitative data validated by the published literature.
Collapse
Affiliation(s)
- Felipe Buson
- College of Chemical and Biological Engineering & ZJU-Hangzhou Global Scientific and Technological Innovation Center, Zhejiang University, Hangzhou 310058, China
- School of Biological Sciences, University of Edinburgh, Edinburgh EH9 3FF, U.K
| | - Yuanli Gao
- College of Chemical and Biological Engineering & ZJU-Hangzhou Global Scientific and Technological Innovation Center, Zhejiang University, Hangzhou 310058, China
- School of Biological Sciences, University of Edinburgh, Edinburgh EH9 3FF, U.K
| | - Baojun Wang
- College of Chemical and Biological Engineering & ZJU-Hangzhou Global Scientific and Technological Innovation Center, Zhejiang University, Hangzhou 310058, China
| |
Collapse
|
11
|
Ma BC, Guo Y, Lin YR, Zhang J, Wang XQ, Zhang WQ, Luo JG, Chen YT, Zhang NX, Lu Q, Hui CY. High-throughput screening of human mercury exposure based on a low-cost naked eye-recognized biosensing platform. Biosens Bioelectron 2024; 248:115961. [PMID: 38150800 DOI: 10.1016/j.bios.2023.115961] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2023] [Revised: 12/05/2023] [Accepted: 12/20/2023] [Indexed: 12/29/2023]
Abstract
Whole-cell biosensors could be helpful for in situ disease diagnosis. However, their use in analyzing biological samples has been hindered by unstable responses, low signal enhancement, and growth inhibition in complex media. Here, we offered a solution by building a visual whole-cell biosensor for urinary mercury determination. With deoxyviolacein as the preferred signal for the mercury biosensor for the first time, it enabled the quantitative detection of urinary mercury with a favorable linear range from 1.57 to 100 nM. The biosensor can accurately diagnose urine mercury levels exceeding the biological exposure index with 95.8% accuracy. Thus, our study provided a biosensing platform with great potential to serve as a stable, user-friendly, and high-throughput alternative for the daily monitoring or estimating of urinary mercury.
Collapse
Affiliation(s)
- Bing-Chan Ma
- School of Public Health, Tongji Medical College, Huazhong University of Science and Technology, 13 Hangkong Road, Wuhan, 430030, China; Shenzhen Prevention and Treatment Center for Occupational Diseases, 2019 Buxin Road, Shenzhen, 518020, China
| | - Yan Guo
- Shenzhen Prevention and Treatment Center for Occupational Diseases, 2019 Buxin Road, Shenzhen, 518020, China
| | - Yi-Ran Lin
- Shenzhen Prevention and Treatment Center for Occupational Diseases, 2019 Buxin Road, Shenzhen, 518020, China
| | - Juan Zhang
- Department of Epidemiology and Biostatistics, School of Public Health, Jilin University, 828 Xinmin Street, Changchun, 130021, China
| | - Xiao-Qiang Wang
- Shenzhen Prevention and Treatment Center for Occupational Diseases, 2019 Buxin Road, Shenzhen, 518020, China
| | - Wen-Qi Zhang
- Shenzhen Prevention and Treatment Center for Occupational Diseases, 2019 Buxin Road, Shenzhen, 518020, China
| | - Jin-Gan Luo
- Shenzhen Prevention and Treatment Center for Occupational Diseases, 2019 Buxin Road, Shenzhen, 518020, China
| | - Yu-Ting Chen
- Shenzhen Prevention and Treatment Center for Occupational Diseases, 2019 Buxin Road, Shenzhen, 518020, China
| | - Nai-Xing Zhang
- Shenzhen Prevention and Treatment Center for Occupational Diseases, 2019 Buxin Road, Shenzhen, 518020, China.
| | - Qing Lu
- School of Public Health, Tongji Medical College, Huazhong University of Science and Technology, 13 Hangkong Road, Wuhan, 430030, China.
| | - Chang-Ye Hui
- Shenzhen Prevention and Treatment Center for Occupational Diseases, 2019 Buxin Road, Shenzhen, 518020, China.
| |
Collapse
|
12
|
Shen L, Chen Y, Hu L, Zhang C, Liu L, Bao L, Ma J, Wang H, Xiao X, Wu L, Chen S. Development of a Highly Sensitive, Visual Platform for the Detection of Cadmium in Actual Wastewater Based on Evolved Whole-Cell Biosensors. ACS Sens 2024; 9:654-661. [PMID: 38329934 DOI: 10.1021/acssensors.3c01811] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/10/2024]
Abstract
A whole-cell biosensor (WCB) is a convenient and cost-effective method for detecting contaminants. However, the practical application of the cadmium WCBs has been hampered by performance deficiencies, such as low sensitivity, specificity, and responsive strength. In this study, to improve the performance of cadmium WCBs, the cadmium transcription factor (CadC) and its DNA binding site (CadO), the key sensing module of the biosensor, were successively and separately subjected to a two-step directed evolution: 6-round random mutagenesis for CadC and 2-round saturation mutagenesis for CadO. For practical application, the GFP reporter gene was replaced with the lacZ gene and a facile and rapid smartphone detection platform for actual water samples was established by optimizing the reaction systems with detergents. The results showed that the evolved cadmium fluorescent biosensor CadO66 exhibited a higher specificity and a detection limit of 0.034 μg/L, representing a 19-fold reduction compared to the wild-type cadmium biosensor. The detergent sodium dodecylbenzenesulfonate effectively enhanced the visualization of WCB B0033-lacZ. Using the fluorescent WCB CadO66 and the visual WCB B0033-lacZ to analyze the cadmium contents of the actual water samples, the results were also consistent with a graphite furnace atomic absorption spectrometer. Taken together, this study indicates that the two-step directed evolution of CadC and CadO can efficiently improve the performance of cadmium WCBs, further promoting the utilization of WCB in actual sample detection and presenting a promising and feasible method for rapid sample detection.
Collapse
Affiliation(s)
- Liang Shen
- Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031, China
- University of Science and Technology of China, Hefei 230026, China
| | - Yiwen Chen
- Wannan Medical College, Wuhu 241002, China
| | - Liangwen Hu
- Wuhu Agricultural Products and Food Testing Center Co. Ltd., Wuhu 241000, China
| | | | | | | | - Jie Ma
- Wannan Medical College, Wuhu 241002, China
| | - Hongqiang Wang
- Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031, China
- University of Science and Technology of China, Hefei 230026, China
| | - Xiang Xiao
- Information Materials and Intelligent Sensing Laboratory of Anhui Province, Institutes of Physical Science and Information Technology, Anhui University, Hefei 230601, China
| | - Lijun Wu
- Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031, China
- University of Science and Technology of China, Hefei 230026, China
- Information Materials and Intelligent Sensing Laboratory of Anhui Province, Institutes of Physical Science and Information Technology, Anhui University, Hefei 230601, China
| | - Shaopeng Chen
- Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031, China
- University of Science and Technology of China, Hefei 230026, China
- Wannan Medical College, Wuhu 241002, China
| |
Collapse
|
13
|
Lind AC, David F, Siewers V. Evaluation and comparison of colorimetric outputs for yeast-based biosensors in laboratory and point-of-use settings. FEMS Microbiol Lett 2024; 371:fnae034. [PMID: 38782713 PMCID: PMC11166083 DOI: 10.1093/femsle/fnae034] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2024] [Revised: 04/30/2024] [Accepted: 05/22/2024] [Indexed: 05/25/2024] Open
Abstract
Recent research has shown the potential of yeast-based biosensors (YBBs) for point-of-use detection of pathogens and target molecules in saliva, blood, and urine samples. The choice of output can greatly affect the sensitivity, dynamic range, detection time, and ease-of-use of a sensor. For visual detection without the need for additional reagents or machinery, colorimetric outputs have shown great potential. Here, we evaluated the inducible generation of prodeoxyviolacein and proviolacein as colorimetric YBB outputs and benchmarked these against lycopene. The outputs were induced via the yeast mating pathway and were compared on agar plates, in liquid culture, and on paper slips. We found that all three outputs produced comparable pigment intensity on agar plates, making them applicable for bioengineering settings. In liquid media and on paper slips, lycopene resulted in a higher intensity pigment and a decreased time-of-detection.
Collapse
Affiliation(s)
- Andrea Clausen Lind
- Department of Life Sciences, Chalmers University of Technology, 412 58 Gothenburg, Sweden
| | - Florian David
- Department of Life Sciences, Chalmers University of Technology, 412 58 Gothenburg, Sweden
| | - Verena Siewers
- Department of Life Sciences, Chalmers University of Technology, 412 58 Gothenburg, Sweden
- Novo Nordisk Foundation Center for Biosustainability, Technical University of Denmark, DK-2800 Kgs. Lyngby, Denmark
| |
Collapse
|
14
|
Kang X, Zhao C, Chen S, Zhang X, Xue B, Li C, Wang S, Yang X, Xia Z, Xu Y, Huang Y, Qiu Z, Li C, Wang J, Pang J, Shen Z. Development of a cell-free toehold switch for hepatitis A virus type I on-site detection. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2023; 15:5813-5822. [PMID: 37870419 DOI: 10.1039/d3ay01408h] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/24/2023]
Abstract
Picornavirus hepatitis A virus (HAV) is a common cause of hepatitis worldwide. It is spread primarily through contaminated food and water or person-to-person contact. HAV I has been identified as the most common type of human HAV infection. Here, we have developed a cell-free toehold switch sensor for HAV I detection. We screened 10 suitable toehold switch sequences using NUPACK software, and the VP1 gene was used as the target gene. The optimal toehold switch sequence was selected by in vivo expression. The best toehold switch concentration was further found to be 20 nM in a cell-free system. 5 nM trigger RNA activated the toehold switch to generate visible green fluorescence. The minimum detection concentration decreased to 1 pM once combined with NASBA. HAV I trigger RNA could be detected accurately with excellent specificity. In addition, the cell-free toehold switch sensor was verified in HAV I entities. The successful construction of the cell-free toehold switch sensor provided a convenient, rapid, and accurate method for HAV I on-site detection, especially in developing countries, without the involvement of expensive facilities and additional professional operators.
Collapse
Affiliation(s)
- Xiaodan Kang
- College of Food Science and Technology, Shanghai Ocean University, Shanghai, 201306, China.
- Tianjin Institute of Environmental and Operational Medicine, Tianjin 300050, China
| | - Chen Zhao
- Tianjin Institute of Environmental and Operational Medicine, Tianjin 300050, China
| | - Shuting Chen
- College of Food Science and Technology, Shanghai Ocean University, Shanghai, 201306, China.
- Tianjin Institute of Environmental and Operational Medicine, Tianjin 300050, China
| | - Xi Zhang
- Tianjin Institute of Environmental and Operational Medicine, Tianjin 300050, China
| | - Bin Xue
- Tianjin Institute of Environmental and Operational Medicine, Tianjin 300050, China
| | - Chenyu Li
- Tianjin Institute of Environmental and Operational Medicine, Tianjin 300050, China
| | - Shang Wang
- Tianjin Institute of Environmental and Operational Medicine, Tianjin 300050, China
| | - Xiaobo Yang
- Tianjin Institute of Environmental and Operational Medicine, Tianjin 300050, China
| | - Zhiqiang Xia
- The 908th Hospital of Chinese People's Liberation Army Joint Logistic Support Force, Nanchang, 330000, China
| | - Yongchun Xu
- The 908th Hospital of Chinese People's Liberation Army Joint Logistic Support Force, Nanchang, 330000, China
| | - Yongliang Huang
- The 908th Hospital of Chinese People's Liberation Army Joint Logistic Support Force, Nanchang, 330000, China
| | - Zhigang Qiu
- Tianjin Institute of Environmental and Operational Medicine, Tianjin 300050, China
| | - Chao Li
- Tianjin Institute of Environmental and Operational Medicine, Tianjin 300050, China
| | - Jingfeng Wang
- Tianjin Institute of Environmental and Operational Medicine, Tianjin 300050, China
| | - Jian Pang
- The Air Force Hospital of Northern Theater People's Liberation Army, Shenyang 110042, China.
| | - Zhiqiang Shen
- College of Food Science and Technology, Shanghai Ocean University, Shanghai, 201306, China.
- Tianjin Institute of Environmental and Operational Medicine, Tianjin 300050, China
| |
Collapse
|
15
|
Zhu K, Chen D, Cai Y, Zhang T, Ma J, Bao L, Zhao F, Wu L, Chen S. Engineering the Ultrasensitive Visual Whole-Cell Biosensors by Evolved MerR and 5' UTR for Detection of Ultratrace Mercury. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2023; 57:16964-16973. [PMID: 37863904 DOI: 10.1021/acs.est.3c04915] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/22/2023]
Abstract
The existing mercury whole-cell biosensors (WCBs, parts per billion range) are not able to meet the real-world requirements due to their lack of sensitivity for the detection of ultratrace mercury in the environment. Ultratrace mercury is a potential threat to human health via the food chain. Here, we developed an ultrasensitive mercury WCB by directed evolution of the mercury-responsive transcriptional activator (MerR) sensing module to detect ultratrace mercury. Subsequently, the mutant WCB (m4-1) responding to mercury in the parts per trillion range after 1 h of induction was obtained. Its detection limit (LOD) was 0.313 ng/L, comparable to those of some analytical instruments. Surprisingly, the m4-1 WCB also responded to methylmercury (LOD = 98 ng/L), which is far more toxic than inorganic mercury. For more convenient detection, we have increased another green fluorescent protein reporter module with an optimized 5' untranslated region (5' UTR) sequence. This yields two visual WCBs with an enhanced fluorescence output. At a concentration of 2.5 ng/L, the fluorescence signals can be directly observed by the naked eye. With the combination of mobile phone imaging and image processing software, the 2GC WCB provided simple, rapid, and reliable quantitative and qualitative analysis of real samples (LOD = 0.307 ng/L). Taken together, these results indicate that the ultrasensitive visual whole-cell biosensors for ultratrace mercury detection are successfully designed using a combination of directed evolution and synthetic biotechnology.
Collapse
Affiliation(s)
- Kaili Zhu
- Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui 230031, P. R. China
- University of Science and Technology of China, Hefei 230026, China, P. R. China
| | - Dongdong Chen
- Institutes of Physical Science and Information Technology, Anhui University, Hefei, Anhui 230601, P. R. China
| | - Yeshen Cai
- Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui 230031, P. R. China
- University of Science and Technology of China, Hefei 230026, China, P. R. China
| | - TianYi Zhang
- School of Public Health, Wannan Medical College, Wuhu 241002, P. R. China
| | - Jie Ma
- School of Public Health, Wannan Medical College, Wuhu 241002, P. R. China
| | - Lingzhi Bao
- School of Public Health, Wannan Medical College, Wuhu 241002, P. R. China
| | - Feng Zhao
- East China Sea Fisheries Research Institute, Chinese Academy of Fishery Sciences, Shanghai 200090, P. R. China
| | - Lijun Wu
- Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui 230031, P. R. China
- University of Science and Technology of China, Hefei 230026, China, P. R. China
| | - Shaopeng Chen
- School of Public Health, Wannan Medical College, Wuhu 241002, P. R. China
| |
Collapse
|
16
|
Hunt JP, Free TJ, Galiardi J, Watt KM, Wood DW, Bundy BC. Streamlining the Detection of Human Thyroid Receptor Ligand Interactions with XL1-Blue Cell-Free Protein Synthesis and Beta-Galactosidase Fusion Protein Biosensors. Life (Basel) 2023; 13:1972. [PMID: 37895354 PMCID: PMC10608756 DOI: 10.3390/life13101972] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2023] [Revised: 09/22/2023] [Accepted: 09/25/2023] [Indexed: 10/29/2023] Open
Abstract
Thyroid receptor signaling controls major physiological processes and disrupted signaling can cause severe disorders that negatively impact human life. Consequently, methods to detect thyroid receptor ligands are of great toxicologic and pharmacologic importance. Previously, we reported thyroid receptor ligand detection with cell-free protein synthesis of a chimeric fusion protein composed of the human thyroid receptor beta (hTRβ) receptor activator and a β-lactamase reporter. Here, we report a 60% reduction in sensing cost by reengineering the chimeric fusion protein biosensor to include a reporter system composed of either the full-length beta galactosidase (β-gal), the alpha fragment of β-gal (β-gal-α), or a split alpha fragment of the β-gal (split β-gal-α). These biosensor constructs are deployed using E. coli XL1-Blue cell extract to (1) avoid the β-gal background activity abundant in BL21 cell extract and (2) facilitate β-gal complementation reporter activity to detect human thyroid receptor ligands. These results constitute a promising platform for high throughput screening and potentially the portable detection of human thyroid receptor ligands.
Collapse
Affiliation(s)
- J. Porter Hunt
- Department of Chemical Engineering, Brigham Young University, Provo, UT 84602, USA
| | - Tyler J. Free
- Department of Chemical Engineering, Brigham Young University, Provo, UT 84602, USA
| | - Jackelyn Galiardi
- Department of Chemical and Biomolecular Engineering, The Ohio State University, Columbus, OH 43210, USA
| | - Kevin M. Watt
- Department of Pediatrics, University of Utah, Salt Lake City, UT 84108, USA
| | - David W. Wood
- Department of Chemical and Biomolecular Engineering, The Ohio State University, Columbus, OH 43210, USA
| | - Bradley C. Bundy
- Department of Chemical Engineering, Brigham Young University, Provo, UT 84602, USA
| |
Collapse
|
17
|
Li W, Xu Y, Zhang Y, Li P, Zhu X, Feng C. Cell-Free Biosensing Genetic Circuit Coupled with Ribozyme Cleavage Reaction for Rapid and Sensitive Detection of Small Molecules. ACS Synth Biol 2023; 12:1657-1666. [PMID: 37196142 DOI: 10.1021/acssynbio.3c00003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/19/2023]
Abstract
Synthetic biological systems have been utilized to develop a wide range of genetic circuits and components that enhance the performance of biosensing systems. Among them, cell-free systems are emerging as important platforms for synthetic biology applications. Genetic circuits play an essential role in cell-free systems, mainly consisting of sensing modules, regulation modules, and signal output modules. Currently, fluorescent proteins and aptamers are commonly used as signal outputs. However, these signal output modes cannot simultaneously achieve faster signal output, more accurate and reliable performance, and signal amplification. Ribozyme is a highly structured and catalytic RNA molecule that can specifically recognize and cut specific substrate sequences. Here, by adopting ribozyme as the signal output, we developed a cell-free biosensing genetic circuit coupled with the ribozyme cleavage reaction, enabling rapid and sensitive detection of small molecules. More importantly, we have also successfully constructed a 3D-printed sensor array and thereby achieved high-throughput analysis of an inhibitory drug. Furthermore, our method will help expand the application range of ribozyme in the field of synthetic biology and also optimize the signal output system of cell-free biosensing, thus promoting the development of cell-free synthetic biology in biomedical research, clinical diagnosis, environmental monitoring, and food inspection.
Collapse
Affiliation(s)
- Wenxing Li
- Center for Molecular Recognition and Biosensing, Shanghai Engineering Research Center of Organ Repair, School of Life Sciences, Shanghai University, Shanghai 200444, P. R. China
- Department of Clinical Laboratory Medicine, Shanghai Tenth People's Hospital of Tongji University, Shanghai 200072, P. R. China
| | - Yiming Xu
- Department of Applied Biology, East China University of Science and Technology, Shanghai 200237, P. R. China
| | - Yue Zhang
- Department of Applied Biology, East China University of Science and Technology, Shanghai 200237, P. R. China
| | - Pengfei Li
- Department of Applied Biology, East China University of Science and Technology, Shanghai 200237, P. R. China
| | - Xiaoli Zhu
- Department of Clinical Laboratory Medicine, Shanghai Tenth People's Hospital of Tongji University, Shanghai 200072, P. R. China
- Shaoxing Institute of Shanghai University, Shaoxing 312071, P. R. China
| | - Chang Feng
- Center for Molecular Recognition and Biosensing, Shanghai Engineering Research Center of Organ Repair, School of Life Sciences, Shanghai University, Shanghai 200444, P. R. China
| |
Collapse
|
18
|
Mao C, Mao Y, Zhu X, Chen G, Feng C. Synthetic biology-based bioreactor and its application in biochemical analysis. Crit Rev Anal Chem 2023; 54:2467-2484. [PMID: 36803337 DOI: 10.1080/10408347.2023.2180319] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/22/2023]
Abstract
In the past few years, synthetic biologists have established some biological elements and bioreactors composed of nucleotides under the guidance of engineering methods. Following the concept of engineering, the common bioreactor components in recent years are introduced and compared. At present, biosensors based on synthetic biology have been applied to water pollution monitoring, disease diagnosis, epidemiological monitoring, biochemical analysis and other detection fields. In this paper, the biosensor components based on synthetic bioreactors and reporters are reviewed. In addition, the applications of biosensors based on cell system and cell-free system in the detection of heavy metal ions, nucleic acid, antibiotics and other substances are presented. Finally, the bottlenecks faced by biosensors and the direction of optimization are also discussed.
Collapse
Affiliation(s)
- Changqing Mao
- Center for Molecular Recognition and Biosensing, School of Life Sciences, Shanghai University, Shanghai, P. R. China
| | - Yichun Mao
- Center for Molecular Recognition and Biosensing, School of Life Sciences, Shanghai University, Shanghai, P. R. China
| | - Xiaoli Zhu
- Department of Clinical Laboratory Medicine, Shanghai Tenth People's Hospital of Tongji University, Shanghai, P. R. China
| | - Guifang Chen
- Center for Molecular Recognition and Biosensing, School of Life Sciences, Shanghai University, Shanghai, P. R. China
- Shanghai Engineering Research Center of Organ Repair, Shanghai University, Shanghai, P. R. China
| | - Chang Feng
- Center for Molecular Recognition and Biosensing, School of Life Sciences, Shanghai University, Shanghai, P. R. China
| |
Collapse
|
19
|
Tellechea-Luzardo J, Stiebritz MT, Carbonell P. Transcription factor-based biosensors for screening and dynamic regulation. Front Bioeng Biotechnol 2023; 11:1118702. [PMID: 36814719 PMCID: PMC9939652 DOI: 10.3389/fbioe.2023.1118702] [Citation(s) in RCA: 12] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2022] [Accepted: 01/26/2023] [Indexed: 02/09/2023] Open
Abstract
Advances in synthetic biology and genetic engineering are bringing into the spotlight a wide range of bio-based applications that demand better sensing and control of biological behaviours. Transcription factor (TF)-based biosensors are promising tools that can be used to detect several types of chemical compounds and elicit a response according to the desired application. However, the wider use of this type of device is still hindered by several challenges, which can be addressed by increasing the current metabolite-activated transcription factor knowledge base, developing better methods to identify new transcription factors, and improving the overall workflow for the design of novel biosensor circuits. These improvements are particularly important in the bioproduction field, where researchers need better biosensor-based approaches for screening production-strains and precise dynamic regulation strategies. In this work, we summarize what is currently known about transcription factor-based biosensors, discuss recent experimental and computational approaches targeted at their modification and improvement, and suggest possible future research directions based on two applications: bioproduction screening and dynamic regulation of genetic circuits.
Collapse
Affiliation(s)
- Jonathan Tellechea-Luzardo
- Institute of Industrial Control Systems and Computing (AI2), Universitat Politècnica de València (UPV), Valencia, Spain
| | - Martin T. Stiebritz
- Institute of Industrial Control Systems and Computing (AI2), Universitat Politècnica de València (UPV), Valencia, Spain
| | - Pablo Carbonell
- Institute of Industrial Control Systems and Computing (AI2), Universitat Politècnica de València (UPV), Valencia, Spain
- Institute for Integrative Systems Biology I2SysBio, Universitat de València-CSIC, Paterna, Spain
| |
Collapse
|
20
|
Dong X, Qi S, Khan IM, Sun Y, Zhang Y, Wang Z. Advances in riboswitch-based biosensor as food samples detection tool. Compr Rev Food Sci Food Saf 2023; 22:451-472. [PMID: 36511082 DOI: 10.1111/1541-4337.13077] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2022] [Revised: 10/09/2022] [Accepted: 10/25/2022] [Indexed: 12/14/2022]
Abstract
Food safety has always been a hot issue of social concern, and biosensing has been widely used in the field of food safety detection. Compared with traditional aptamer-based biosensors, aptamer-based riboswitch biosensing represents higher precision and programmability. A riboswitch is an elegant example of controlling gene expression, where the target is coupled to the aptamer domain, resulting in a conformational change in the downstream expression domain and determining the signal output. Riboswitch-based biosensing can be extensively applied to the portable real-time detection of food samples. The numerous key features of riboswitch-based biosensing emphasize their sustainability, renewable, and testing, which promises to transform engineering applications in the field of food safety. This review covers recent developments in riboswitch-based biosensors. The brief history, definition, and modular design (regulatory mode, reporter, and expression platform) of riboswitch-based biosensors are explained for better insight into the design and construction. We summarize recent advances in various riboswitch-based biosensors involving theophylline, malachite green, tetracycline, neomycin, fluoride, thrombin, naringenin, ciprofloxacin, and paromomycin, aiming to provide general guidance for the design of riboswitch-based biosensors. Finally, the challenges and prospects are also summarized as a way forward stratagem and signs of progress.
Collapse
Affiliation(s)
- Xiaoze Dong
- State Key Laboratory of Food Science and Technology, International Joint Laboratory on Food Safety, Jiangnan University, Wuxi, China
| | - Shuo Qi
- State Key Laboratory of Food Science and Technology, International Joint Laboratory on Food Safety, Jiangnan University, Wuxi, China
| | - Imran Mahmood Khan
- State Key Laboratory of Food Science and Technology, International Joint Laboratory on Food Safety, Jiangnan University, Wuxi, China
| | - Yuhan Sun
- State Key Laboratory of Food Science and Technology, International Joint Laboratory on Food Safety, Jiangnan University, Wuxi, China
| | - Yin Zhang
- Key Laboratory of Meat Processing of Sichuan, Chengdu University, Chengdu, China
| | - Zhouping Wang
- State Key Laboratory of Food Science and Technology, International Joint Laboratory on Food Safety, Jiangnan University, Wuxi, China.,School of Food Science and Technology, Jiangnan University, Wuxi, China.,Key Laboratory of Meat Processing of Sichuan, Chengdu University, Chengdu, China.,National Engineering Research Center for Functional Food, Jiangnan University, Wuxi, China.,Collaborative innovation center of food safety and quality control in Jiangsu Province, Food, Jiangnan University, Wuxi, China
| |
Collapse
|
21
|
Patterson AT, Styczynski MP. Rapid and Finely-Tuned Expression for Deployable Sensing Applications. ADVANCES IN BIOCHEMICAL ENGINEERING/BIOTECHNOLOGY 2023; 186:141-161. [PMID: 37316621 DOI: 10.1007/10_2023_223] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
Abstract
Organisms from across the tree of life have evolved highly efficient mechanisms for sensing molecules of interest using biomolecular machinery that can in turn be quite valuable for the development of biosensors. However, purification of such machinery for use in in vitro biosensors is costly, while the use of whole cells as in vivo biosensors often leads to long sensor response times and unacceptable sensitivity to the chemical makeup of the sample. Cell-free expression systems overcome these weaknesses by removing the requirements associated with maintaining living sensor cells, allowing for increased function in toxic environments and rapid sensor readout at a production cost that is often more reasonable than purification. Here, we focus on the challenge of implementing cell-free protein expression systems that meet the stringent criteria required for them to serve as the basis for field-deployable biosensors. Fine-tuning expression to meet these requirements can be achieved through careful selection of the sensing and output elements, as well as through optimization of reaction conditions via tuning of DNA/RNA concentrations, lysate preparation methods, and buffer conditions. Through careful sensor engineering, cell-free systems can continue to be successfully used for the production of tightly regulated, rapidly expressing genetic circuits for biosensors.
Collapse
Affiliation(s)
- Alexandra T Patterson
- School of Chemical and Biomolecular Engineering, Georgia Institute of Technology, Atlanta, GA, USA
| | - Mark P Styczynski
- School of Chemical and Biomolecular Engineering, Georgia Institute of Technology, Atlanta, GA, USA.
| |
Collapse
|
22
|
Ghosh B. Artificial cell design: reconstructing biology for life science applications. Emerg Top Life Sci 2022; 6:619-627. [PMID: 36398710 DOI: 10.1042/etls20220050] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2022] [Revised: 10/12/2022] [Accepted: 11/07/2022] [Indexed: 11/19/2022]
Abstract
Artificial cells are developed to redesign novel biological functions in a programmable and tunable manner. Although it aims to reconstitute living cell features and address 'origin of life' related questions, rapid development over the years has transformed artificial cells into an engineering tool with huge potential in applied biotechnology. Although the application of artificial cells was introduced decades ago as drug carriers, applications in other sectors are relatively new and could become possible with the technological advancement that can modulate its designing principles. Artificial cells are non-living system that includes no prerequisite designing modules for their formation and therefore allow freedom of assembling desired biological machinery within a physical boundary devoid of complex contemporary living-cell counterparts. As stimuli-responsive biomimetic tools, artificial cells are programmed to sense the surrounding, recognise their target, activate its function and perform the defined task. With the advantage of their customised design, artificial cells are being studied in biosensing, drug delivery, anti-cancer therapeutics or artificial photosynthesis type fields. This mini-review highlights those advanced fields where artificial cells with a minimalistic setup are developed as user-defined custom-made microreactors, targeting to reshape our future 'life'.
Collapse
Affiliation(s)
- Basusree Ghosh
- Max Planck Institute of Molecular Cell Biology and Genetics, Pfotenhauerstraße 108, 01307 Dresden, Germany
| |
Collapse
|
23
|
VanArsdale E, Pitzer J, Wang S, Stephens K, Chen CY, Payne GF, Bentley WE. Enhanced electrochemical measurement of β-galactosidase activity in whole cells by coexpression of lactose permease, LacY. Biotechniques 2022; 73:233-237. [DOI: 10.2144/btn-2022-0090] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
Whole-cell biosensing links the sensing and computing capabilities of microbes to the generation of a detectable reporter. Whole cells enable dynamic biological computation (filtered noise, amplified signals, logic gating etc.). Enzymatic reporters enable in situ signal amplification. Electrochemical measurements are easily quantified and work in turbid environments. In this work we show how the coexpression of the lactose permease, LacY, dramatically improves electrochemical sensing of β-galactosidase (LacZ) expressed as a reporter in whole cells. The permease facilitates transport of the LacZ substrate, 4-aminophenyl β-d-galactopyranoside, which is converted to redox active p-aminophenol, which, in turn, is detected via cyclic voltammetry or chronocoulometry. We show a greater than fourfold improvement enabled by lacY coexpression in cells engineered to respond to bacterial signal molecules, pyocyanin and quorum-sensing autoinducer-2.
Collapse
Affiliation(s)
- Eric VanArsdale
- Fischell Department of Bioengineering, University of Maryland, College Park, MD 20742, USA
- Institute for Bioscience & Biotechnology Research, University of Maryland, College Park, MD 20742, USA
- Fischell Institute for Biomedical Devices, University of Maryland, College Park, MD 20742, USA
| | - Juliana Pitzer
- Fischell Department of Bioengineering, University of Maryland, College Park, MD 20742, USA
| | - Sally Wang
- Fischell Department of Bioengineering, University of Maryland, College Park, MD 20742, USA
- Institute for Bioscience & Biotechnology Research, University of Maryland, College Park, MD 20742, USA
- Fischell Institute for Biomedical Devices, University of Maryland, College Park, MD 20742, USA
| | - Kristina Stephens
- Fischell Department of Bioengineering, University of Maryland, College Park, MD 20742, USA
- Institute for Bioscience & Biotechnology Research, University of Maryland, College Park, MD 20742, USA
- Fischell Institute for Biomedical Devices, University of Maryland, College Park, MD 20742, USA
| | - Chen-yu Chen
- Fischell Department of Bioengineering, University of Maryland, College Park, MD 20742, USA
- Institute for Bioscience & Biotechnology Research, University of Maryland, College Park, MD 20742, USA
- Fischell Institute for Biomedical Devices, University of Maryland, College Park, MD 20742, USA
| | - Gregory F Payne
- Institute for Bioscience & Biotechnology Research, University of Maryland, College Park, MD 20742, USA
- Fischell Institute for Biomedical Devices, University of Maryland, College Park, MD 20742, USA
| | - William E Bentley
- Fischell Department of Bioengineering, University of Maryland, College Park, MD 20742, USA
- Institute for Bioscience & Biotechnology Research, University of Maryland, College Park, MD 20742, USA
- Fischell Institute for Biomedical Devices, University of Maryland, College Park, MD 20742, USA
| |
Collapse
|
24
|
Zou ZP, Yang Y, Wang J, Zhou Y, Ye BC. Coupling split-lux cassette with a toggle switch in bacteria for ultrasensitive blood markers detection in feces and urine. Biosens Bioelectron 2022; 214:114520. [DOI: 10.1016/j.bios.2022.114520] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2022] [Revised: 06/24/2022] [Accepted: 06/26/2022] [Indexed: 11/29/2022]
|
25
|
A Luciferase Mutant with Improved Brightness and Stability for Whole-Cell Bioluminescent Biosensors and In Vitro Biosensing. BIOSENSORS 2022; 12:bios12090742. [PMID: 36140127 PMCID: PMC9496056 DOI: 10.3390/bios12090742] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/06/2022] [Revised: 08/30/2022] [Accepted: 09/05/2022] [Indexed: 11/17/2022]
Abstract
The availability of new bioluminescent proteins with tuned properties, both in terms of emission wavelength, kinetics and protein stability, is highly valuable in the bioanalytical field, with the potential to improve the sensitivity and analytical performance of the currently used methods for ATP detection, whole-cell biosensors, and viability assays among others. We present a new luciferase mutant, called BgLuc, suitable for developing whole-cell biosensors and in vitro biosensors characterized by a bioluminescence maximum of 548 nm, narrow emission bandwidth, favorable kinetic properties, and excellent pH- and thermo-stabilities at 37 and 45 °C and pH from 5.0 to 8.0. We assessed the suitability of this new luciferase for whole-cell biosensing with a cell-based bioreporter assay for Nuclear Factor-kappa B (NF-kB) signal transduction pathway using 2D and 3D human embryonic kidney (HEK293T) cells, and for ATP detection with the purified enzyme. In both cases the luciferase showed suitable for sensitive detection of the target analytes, with better or similar performance than the commercial counterparts.
Collapse
|
26
|
Zúñiga A, Muñoz-Guamuro G, Boivineau L, Mayonove P, Conejero I, Pageaux GP, Altwegg R, Bonnet J. A rapid and standardized workflow for functional assessment of bacterial biosensors in fecal samples. Front Bioeng Biotechnol 2022; 10:859600. [PMID: 36072290 PMCID: PMC9444133 DOI: 10.3389/fbioe.2022.859600] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2022] [Accepted: 07/05/2022] [Indexed: 11/17/2022] Open
Abstract
Gut metabolites are pivotal mediators of host-microbiome interactions and provide an important window on human physiology and disease. However, current methods to monitor gut metabolites rely on heavy and expensive technologies such as liquid chromatography-mass spectrometry (LC-MS). In that context, robust, fast, field-deployable, and cost-effective strategies for monitoring fecal metabolites would support large-scale functional studies and routine monitoring of metabolites biomarkers associated with pathological conditions. Living cells are an attractive option to engineer biosensors due to their ability to detect and process many environmental signals and their self-replicating nature. Here we optimized a workflow for feces processing that supports metabolite detection using bacterial biosensors. We show that simple centrifugation and filtration steps remove host microbes and support reproducible preparation of a physiological-derived media retaining important characteristics of human feces, such as matrix effects and endogenous metabolites. We measure the performance of bacterial biosensors for benzoate, lactate, anhydrotetracycline, and bile acids, and find that they are highly sensitive to fecal matrices. However, encapsulating the bacteria in hydrogel helps reduce this inhibitory effect. Sensitivity to matrix effects is biosensor-dependent but also varies between individuals, highlighting the need for case-by-case optimization for biosensors’ operation in feces. Finally, by detecting endogenous bile acids, we demonstrate that bacterial biosensors could be used for future metabolite monitoring in feces. This work lays the foundation for the optimization and use of bacterial biosensors for fecal metabolites monitoring. In the future, our method could also allow rapid pre-prototyping of engineered bacteria designed to operate in the gut, with applications to in situ diagnostics and therapeutics.
Collapse
Affiliation(s)
- Ana Zúñiga
- Centre de Biologie Structurale (CBS), INSERM U1054, CNRS UMR5048, University of Montpellier, Montpellier, France
- *Correspondence: Ana Zúñiga, ; Jerome Bonnet,
| | - Geisler Muñoz-Guamuro
- Centre de Biologie Structurale (CBS), INSERM U1054, CNRS UMR5048, University of Montpellier, Montpellier, France
| | - Lucile Boivineau
- Hepatogastroenterology and Bacteriology Service at CHU Montpellier, University of Montpellier, Montpellier, France
| | - Pauline Mayonove
- Centre de Biologie Structurale (CBS), INSERM U1054, CNRS UMR5048, University of Montpellier, Montpellier, France
| | - Ismael Conejero
- Department of Psychiatry, CHU Nimes, University of Montpellier, Montpellier, France
| | - Georges-Philippe Pageaux
- Hepatogastroenterology and Bacteriology Service at CHU Montpellier, University of Montpellier, Montpellier, France
| | - Romain Altwegg
- Hepatogastroenterology and Bacteriology Service at CHU Montpellier, University of Montpellier, Montpellier, France
| | - Jerome Bonnet
- Centre de Biologie Structurale (CBS), INSERM U1054, CNRS UMR5048, University of Montpellier, Montpellier, France
- *Correspondence: Ana Zúñiga, ; Jerome Bonnet,
| |
Collapse
|
27
|
Copeland CE, Kim J, Copeland PL, Heitmeier CJ, Kwon YC. Characterizing a New Fluorescent Protein for a Low Limit of Detection Sensing in the Cell-Free System. ACS Synth Biol 2022; 11:2800-2810. [PMID: 35850511 PMCID: PMC9396652 DOI: 10.1021/acssynbio.2c00180] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Cell-free protein synthesis-based biosensors have been developed as highly accurate, low-cost biosensors. However, since most biomarkers exist at low concentrations in various types of biopsies, the biosensor's dynamic range must be increased in the system to achieve low limits of detection necessary while deciphering from higher background signals. Many attempts to increase the dynamic range have relied on amplifying the input signal from the analyte, which can lead to complications of false positives. In this study, we aimed to increase the protein synthesis capability of the cell-free protein synthesis system and the output signal of the reporter protein to achieve a lower limit of detection. We utilized a new fluorescent protein, mNeonGreen, which produces a higher output than those commonly used in cell-free biosensors. Optimizations of DNA sequence and the subsequent cell-free protein synthesis reaction conditions allowed characterizing protein expression variability by given DNA template types, reaction environment, and storage additives that cause the greatest time constraint on designing the cell-free biosensor. Finally, we characterized the fluorescence kinetics of mNeonGreen compared to the commonly used reporter protein, superfolder green fluorescent protein. We expect that this finely tuned cell-free protein synthesis platform with the new reporter protein can be used with sophisticated synthetic gene circuitry networks to increase the dynamic range of a cell-free biosensor to reach lower detection limits and reduce the false-positive proportion.
Collapse
Affiliation(s)
- Caroline E Copeland
- Department of Biological and Agricultural Engineering, Louisiana State University, Baton Rouge, Louisiana 70803, United States
| | - Jeehye Kim
- Department of Biological and Agricultural Engineering, Louisiana State University, Baton Rouge, Louisiana 70803, United States
| | - Pearce L Copeland
- Department of Biological and Agricultural Engineering, Louisiana State University, Baton Rouge, Louisiana 70803, United States
| | - Chloe J Heitmeier
- Department of Biological and Agricultural Engineering, Louisiana State University, Baton Rouge, Louisiana 70803, United States
| | - Yong-Chan Kwon
- Department of Biological and Agricultural Engineering, Louisiana State University, Baton Rouge, Louisiana 70803, United States.,Louisiana State University Agricultural Center, Baton Rouge, Louisiana 70803, United States
| |
Collapse
|
28
|
Harbaugh SV, Silverman AD, Chushak YG, Zimlich K, Wolfe M, Thavarajah W, Jewett MC, Lucks JB, Chávez JL. Engineering a Synthetic Dopamine-Responsive Riboswitch for In Vitro Biosensing. ACS Synth Biol 2022; 11:2275-2283. [PMID: 35775197 DOI: 10.1021/acssynbio.1c00560] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
The detection of chemicals using natural allosteric transcription factors is a powerful strategy for point-of-use molecular sensing, particularly using fieldable cell-free gene expression (CFE) systems. However, the reliance of detection schemes on characterized protein-based sensors limits the number of measurable analytes. One alternative solution to this issue is to develop new sensors by generating RNA aptamers against the target analyte and then incorporating them directly into a riboswitch scaffold for ligand-inducible genetic control of a reporter protein. However, this strategy has not generated more than a handful of successful portable cell-free molecular sensors. To address this gap, here we convert dopamine-binding aptamers into functional dopamine-sensing riboswitches that regulate gene expression in a freeze-dried CFE reaction. We then develop an assay for direct detection and semi-quantification of dopamine in human urine. We anticipate that this work will be broadly applicable for converting many in vitro-generated RNA aptamers into fieldable molecular diagnostics.
Collapse
Affiliation(s)
- Svetlana V Harbaugh
- 711th Human Performance Wing, Air Force Research Laboratory, Wright-Patterson Air Force Base, Ohio 45433, United States
| | - Adam D Silverman
- Sherlock Biosciences, Boston, Massachusetts 02135, United States
| | - Yaroslav G Chushak
- 711th Human Performance Wing, Air Force Research Laboratory, Wright-Patterson Air Force Base, Ohio 45433, United States.,Henry M. Jackson Foundation, Dayton, Ohio 45433, United States
| | - Kathryn Zimlich
- 711th Human Performance Wing, Air Force Research Laboratory, Wright-Patterson Air Force Base, Ohio 45433, United States.,Henry M. Jackson Foundation, Dayton, Ohio 45433, United States
| | - Monica Wolfe
- 711th Human Performance Wing, Air Force Research Laboratory, Wright-Patterson Air Force Base, Ohio 45433, United States.,UES, Inc., Dayton, Ohio 45432, United States
| | - Walter Thavarajah
- Department of Chemical and Biological Engineering, Northwestern University, Evanston, Illinois 60208, United States.,Center for Synthetic Biology, Northwestern University, Evanston, Illinois 60208, United States
| | - Michael C Jewett
- Department of Chemical and Biological Engineering, Northwestern University, Evanston, Illinois 60208, United States.,Center for Synthetic Biology, Northwestern University, Evanston, Illinois 60208, United States.,Interdisciplinary Biological Sciences Program, Northwestern University, Evanston, Illinois 60208, United States.,International Institute of Nanotechnology, Northwestern University, Evanston, Illinois 60208, United States
| | - Julius B Lucks
- Department of Chemical and Biological Engineering, Northwestern University, Evanston, Illinois 60208, United States.,Center for Synthetic Biology, Northwestern University, Evanston, Illinois 60208, United States.,Interdisciplinary Biological Sciences Program, Northwestern University, Evanston, Illinois 60208, United States.,International Institute of Nanotechnology, Northwestern University, Evanston, Illinois 60208, United States
| | - Jorge L Chávez
- 711th Human Performance Wing, Air Force Research Laboratory, Wright-Patterson Air Force Base, Ohio 45433, United States
| |
Collapse
|
29
|
Transcription Factor-Based Biosensors for Detecting Pathogens. BIOSENSORS 2022; 12:bios12070470. [PMID: 35884273 PMCID: PMC9312912 DOI: 10.3390/bios12070470] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/19/2022] [Revised: 06/21/2022] [Accepted: 06/27/2022] [Indexed: 12/23/2022]
Abstract
Microorganisms are omnipresent and inseparable from our life. Many of them are beneficial to humans, while some are not. Importantly, foods and beverages are susceptible to microbial contamination, with their toxins causing illnesses and even death in some cases. Therefore, monitoring and detecting harmful microorganisms are critical to ensuring human health and safety. For several decades, many methods have been developed to detect and monitor microorganisms and their toxicants. Conventionally, nucleic acid analysis and antibody-based analysis were used to detect pathogens. Additionally, diverse chromatographic methods were employed to detect toxins based on their chemical and structural properties. However, conventional techniques have several disadvantages concerning analysis time, sensitivity, and expense. With the advances in biotechnology, new approaches to detect pathogens and toxins have been reported to compensate for the disadvantages of conventional analysis from different research fields, including electrochemistry, nanotechnology, and molecular biology. Among them, we focused on the recent studies of transcription factor (TF)-based biosensors to detect microorganisms and discuss their perspectives and applications. Additionally, the other biosensors for detecting microorganisms reported in recent studies were also introduced in this review.
Collapse
|
30
|
Chen SY, Zhang Y, Li R, Wang B, Ye BC. De Novo Design of the ArsR Regulated P ars Promoter Enables a Highly Sensitive Whole-Cell Biosensor for Arsenic Contamination. Anal Chem 2022; 94:7210-7218. [PMID: 35537205 PMCID: PMC9134189 DOI: 10.1021/acs.analchem.2c00055] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Whole-cell biosensors for arsenic contamination are typically designed based on natural bacterial sensing systems, which are often limited by their poor performance for precisely tuning the genetic response to environmental stimuli. Promoter design remains one of the most important approaches to address such issues. Here, we use the arsenic-responsive ArsR-Pars regulation system from Escherichia coli MG1655 as the sensing element and coupled gfp or lacZ as the reporter gene to construct the genetic circuit for characterizing the refactored promoters. We first analyzed the ArsR binding site and a library of RNA polymerase binding sites to mine potential promoter sequences. A set of tightly regulated Pars promoters by ArsR was designed by placing the ArsR binding sites into the promoter's core region, and a novel promoter with maximal repression efficiency and optimal fold change was obtained. The fluorescence sensor PlacV-ParsOC2 constructed with the optimized ParsOC2 promoter showed a fold change of up to 63.80-fold (with green fluorescence visible to the naked eye) at 9.38 ppb arsenic, and the limit of detection was as low as 0.24 ppb. Further, the optimized colorimetric sensor PlacV-ParsOC2-lacZ with a linear response between 0 and 5 ppb was used to perform colorimetric reactions in 24-well plates combined with a smartphone application for the quantification of the arsenic level in groundwater. This study offers a new approach to improve the performance of bacterial sensing promoters and will facilitate the on-site application of arsenic whole-cell biosensors.
Collapse
Affiliation(s)
- Sheng-Yan Chen
- School
of Chemistry and Chemical Engineering, Shihezi
University, Shihezi 832003, China
| | - Yan Zhang
- School
of Chemistry and Chemical Engineering, Shihezi
University, Shihezi 832003, China
| | - Renjie Li
- School
of Chemistry and Chemical Engineering, Shihezi
University, Shihezi 832003, China
| | - Baojun Wang
- College
of Chemical and Biological Engineering & ZJU-Hangzhou Global Scientific
and Technological Innovation Center, Zhejiang
University, Hangzhou 311200, China,Research
Center of Biological Computation, Zhejiang
Laboratory, Hangzhou 311100, China,Centre
for Synthetic and Systems Biology, School of Biological Sciences, University of Edinburgh, Edinburgh EH9 3FF, United Kingdom,
| | - Bang-Ce Ye
- School
of Chemistry and Chemical Engineering, Shihezi
University, Shihezi 832003, China,Institute
of Engineering Biology and Health, Collaborative Innovation Center
of Yangtze River Delta Region Green Pharmaceuticals, College of Pharmaceutical
Sciences, Zhejiang University of Technology, Hangzhou 310014, Zhejiang, China,Lab of Biosystem
and Microanalysis, State Key Laboratory of Bioreactor Engineering, East China University of Science and Technology, Shanghai 200237, China,. Tel/Fax: 0086-21-64252094
| |
Collapse
|
31
|
Lee YJ, Lee S, Kim DM. Translational Detection of Indole by Complementary Cell-free Protein Synthesis Assay. Front Bioeng Biotechnol 2022; 10:900162. [PMID: 35646868 PMCID: PMC9136167 DOI: 10.3389/fbioe.2022.900162] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2022] [Accepted: 04/28/2022] [Indexed: 11/16/2022] Open
Abstract
The information encoded in a single copy of DNA is processed into a plethora of protein molecules via the cascade of transcription and translation. Thus, the molecular process of gene expression can be considered an efficient biological amplifier from the viewpoint of synthetic biology. Cell-free protein synthesis (CFPS) enables the implementation of this amplification module for in vitro analysis of important biomolecules and avoids many of the problems associated with whole cell-based approaches. Here, we developed a method to analyze indole by using a combination of enzymatic conversion of indole and amino acid-dependent CFPS. In this method, indole molecules in the assay sample are used to generate tryptophan, which is incorporated into signal-generating proteins in the subsequent cell-free synthesis reaction. The activity of cell-free synthesized proteins was successfully used to estimate the indole concentration in the assay sample. In principle, the developed method could be extended to analyses of other important bioactive compounds.
Collapse
Affiliation(s)
- You Jin Lee
- Department of Chemical Engineering and Applied Chemistry, Daejeon, Korea
| | - Soojin Lee
- Department of Microbiology and Molecular Biology, Chungnam National University, Daejeon, Korea
| | - Dong-Myung Kim
- Department of Chemical Engineering and Applied Chemistry, Daejeon, Korea
| |
Collapse
|
32
|
Wang T, Lu Y. Advances, Challenges and Future Trends of Cell-Free Transcription-Translation Biosensors. BIOSENSORS 2022; 12:bios12050318. [PMID: 35624619 PMCID: PMC9138237 DOI: 10.3390/bios12050318] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/04/2022] [Revised: 05/07/2022] [Accepted: 05/08/2022] [Indexed: 11/16/2022]
Abstract
In recent years, the application of cell-free protein synthesis systems in biosensing has been developing rapidly. Cell-free synthetic biology, with its advantages of high biosafety, fast material transport, and high sensitivity, has overcome many defects of cell-based biosensors and provided an abiotic substitute for biosensors. In addition, the application of freeze-drying technology has improved the stability of such systems, making it possible to realize point-of-care application of field detection and broadening the application prospects of cell-free biosensors. However, despite these advancements, challenges such as the risk of sample interference due to the lack of physical barriers, maintenance of activity during storage, and poor robustness still need to be addressed before the full potential of cell-free biosensors can be realized on a larger scale. In this review, current strategies and research results for improving the performance of cell-free biosensors are summarized, including a comprehensive discussion of the existing challenges, future trends, and potential investments needed for improvement.
Collapse
|
33
|
Sankar K, Baer R, Grazon C, Sabatelle RC, Lecommandoux S, Klapperich CM, Galagan JE, Grinstaff MW. An Allosteric Transcription Factor DNA-Binding Electrochemical Biosensor for Progesterone. ACS Sens 2022; 7:1132-1137. [PMID: 35412319 PMCID: PMC9985479 DOI: 10.1021/acssensors.2c00133] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
Abstract
We describe an electrochemical strategy to transduce allosteric transcription factor (aTF) binding affinity to sense steroid hormones. Our approach utilizes square wave voltammetry to monitor changes in current output as a progesterone (PRG)-specific aTF (SRTF1) unbinds from the cognate DNA sequence in the presence of PRG. The sensor detects PRG in artificial urine samples with sufficient sensitivity suitable for clinical applications. Our results highlight the capability of using aTFs as the biorecognition elements to develop electrochemical point-of-care biosensors for the detection of small-molecule biomarkers and analytes.
Collapse
Affiliation(s)
- Karthika Sankar
- Division of Materials Science and Engineering, Boston University, Boston, MA 02215, USA
| | - R Baer
- Department of Microbiology, Boston University, Boston, MA 02215, USA
| | - Chloé Grazon
- Department of Chemistry, Boston University, Boston, MA 02215, USA.,Department of Biomedical Engineering, Boston University, Boston, MA 02215, USA.,University Bordeaux, CNRS, Bordeaux INP, LCPO, UMR 5629, F-33600, Pessac, France.,University Bordeaux, Institut des Sciences Moléculaires (CNRS UMR 5255), 33405 Talence, France
| | - Robert C. Sabatelle
- Department of Biomedical Engineering, Boston University, Boston, MA 02215, USA
| | | | - Catherine M. Klapperich
- Division of Materials Science and Engineering, Boston University, Boston, MA 02215, USA.,Department of Biomedical Engineering, Boston University, Boston, MA 02215, USA
| | - James E. Galagan
- Department of Microbiology, Boston University, Boston, MA 02215, USA.,Department of Biomedical Engineering, Boston University, Boston, MA 02215, USA.,Corresponding Author James E. Galagan; , Mark W. Grinstaff;
| | - Mark W. Grinstaff
- Division of Materials Science and Engineering, Boston University, Boston, MA 02215, USA.,Department of Chemistry, Boston University, Boston, MA 02215, USA.,Department of Biomedical Engineering, Boston University, Boston, MA 02215, USA.,Corresponding Author James E. Galagan; , Mark W. Grinstaff;
| |
Collapse
|
34
|
Miller CA, Ho JML, Bennett MR. Strategies for Improving Small-Molecule Biosensors in Bacteria. BIOSENSORS 2022; 12:bios12020064. [PMID: 35200325 PMCID: PMC8869690 DOI: 10.3390/bios12020064] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/16/2021] [Revised: 01/14/2022] [Accepted: 01/18/2022] [Indexed: 05/03/2023]
Abstract
In recent years, small-molecule biosensors have become increasingly important in synthetic biology and biochemistry, with numerous new applications continuing to be developed throughout the field. For many biosensors, however, their utility is hindered by poor functionality. Here, we review the known types of mechanisms of biosensors within bacterial cells, and the types of approaches for optimizing different biosensor functional parameters. Discussed approaches for improving biosensor functionality include methods of directly engineering biosensor genes, considerations for choosing genetic reporters, approaches for tuning gene expression, and strategies for incorporating additional genetic modules.
Collapse
Affiliation(s)
- Corwin A. Miller
- Department of Biosciences, Rice University MS-140, 6100 Main St., Houston, TX 77005, USA; (C.A.M.); (J.M.L.H.)
| | - Joanne M. L. Ho
- Department of Biosciences, Rice University MS-140, 6100 Main St., Houston, TX 77005, USA; (C.A.M.); (J.M.L.H.)
| | - Matthew R. Bennett
- Department of Biosciences, Rice University MS-140, 6100 Main St., Houston, TX 77005, USA; (C.A.M.); (J.M.L.H.)
- Department of Bioengineering, Rice University MS-140, 6100 Main St., Houston, TX 77005, USA
- Correspondence:
| |
Collapse
|
35
|
|
36
|
Belkin S, Wang B. Sense and sensibility: of synthetic biology and the redesign of bioreporter circuits. Microb Biotechnol 2022; 15:103-106. [PMID: 34689402 PMCID: PMC8719829 DOI: 10.1111/1751-7915.13955] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2021] [Accepted: 10/11/2021] [Indexed: 11/29/2022] Open
Affiliation(s)
- Shimshon Belkin
- Institute of Life Sciencesthe Hebrew University of JerusalemJerusalem9190401Israel
| | - Baojun Wang
- School of Biological SciencesUniversity of EdinburghEdinburghEH9 3FFUK
- Hangzhou Innovation Center and College of Chemical and Biological EngineeringZhejiang UniversityHangzhou311200China
| |
Collapse
|
37
|
Tsai ST, Cheng WJ, Zhang QX, Yeh YC. Gold-Specific Biosensor for Monitoring Wastewater Using Genetically Engineered Cupriavidus metallidurans CH34. ACS Synth Biol 2021; 10:3576-3582. [PMID: 34860511 DOI: 10.1021/acssynbio.1c00520] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
Transcription factor-based whole-cell biosensors have recently become promising alternatives to conventional analytical methods due to their advantage of simplicity, cost-effectiveness, and environmental friendliness. In this study, we used genetic engineering to develop a whole-cell biosensor based on the activation of promoters by CupR via interactions with gold ions, leading to the expression of reporter genes that yield output signals. Altering the promoter sequences was shown to significantly improve the performance of the biosensor strain in terms of gold-specificity. The detection sensitivity of our engineered strains was 42-fold higher than that of wild-type strains. The linear range of the purposed sensor was 125-1000 nM with a limit of detection at 46.5 nM. The effectiveness of the sensor strain was verified in wastewater samples.
Collapse
Affiliation(s)
- Ssu-Tzu Tsai
- Department of Chemistry, National Taiwan Normal University, Taipei 116, Taiwan
| | - Wen-Jui Cheng
- Department of Chemistry, National Taiwan Normal University, Taipei 116, Taiwan
| | - Qian-Xian Zhang
- Department of Chemistry, National Taiwan Normal University, Taipei 116, Taiwan
| | - Yi-Chun Yeh
- Department of Chemistry, National Taiwan Normal University, Taipei 116, Taiwan
| |
Collapse
|
38
|
Lopreside A, Montali L, Wang B, Tassoni A, Ferri M, Calabretta MM, Michelini E. Orthogonal paper biosensor for mercury(II) combining bioluminescence and colorimetric smartphone detection. Biosens Bioelectron 2021; 194:113569. [PMID: 34438340 DOI: 10.1016/j.bios.2021.113569] [Citation(s) in RCA: 23] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2021] [Revised: 08/13/2021] [Accepted: 08/16/2021] [Indexed: 01/02/2023]
Abstract
Mercury contamination in the environment has reached alarming levels. Due to its persistence and bioaccumulation, mercury is one of the most widespread toxic heavy metals found in air, water and food. Thus, it is mandatory to monitor mercury and its compounds, and the availability of sensitive and rapid biosensors is highly valuable. We developed a low-cost biosensor for orthogonal detection of mercury(II) integrating three different biorecognition principles on a three-leaf paper: i) a mercury-specific bioluminescent Escherichia coli bioreporter strain expressing NanoLuc luciferase as reporter protein, ii) a purified β-galactosidase (β-gal) enzyme which is irreversibly inhibited by mercury and other metal ions, and iii) an Aliivibrio fischeri bioluminescent strain which is used to quantitatively assess sample toxicity and correct the analytical signal accordingly. Both sensory elements and substrates, Furimazine for the bioluminescent reporter strain and chlorophenol red-β-D-galactopyranoside for colorimetric detection of β-gal, were integrated in the paper sensor to provide a stable all-in-one disposable cartridge which can be easily snapped into a smartphone with a clover-shaped 3D printed housing. This is the first integration of bioluminescence and colorimetric detection on a smartphone-paper sensor, providing a readout within 15 and 60 min for the colorimetric and bioluminescent detection respectively. The biosensor was applied to water samples spiked with different concentrations of mercury, interferents and toxic chemicals providing a limit of detection for Hg(II) at the ppb levels.
Collapse
Affiliation(s)
- Antonia Lopreside
- Department of Chemistry "Giacomo Ciamician", University of Bologna, Via Selmi 2, 40126, Bologna, Italy; Center for Applied Biomedical Research (CRBA), Azienda Ospedaliero-Universitaria Policlinico S. Orsola-Malpighi, Bologna, Italy
| | - Laura Montali
- Department of Chemistry "Giacomo Ciamician", University of Bologna, Via Selmi 2, 40126, Bologna, Italy; Center for Applied Biomedical Research (CRBA), Azienda Ospedaliero-Universitaria Policlinico S. Orsola-Malpighi, Bologna, Italy
| | - Baojun Wang
- Centre for Synthetic and Systems Biology, School of Biological Sciences, University of Edinburgh, Edinburgh, United Kingdom; Hangzhou Innovation Center, College of Chemical and Biological Engineering, Zhejiang University, Hangzhou, 311200, China
| | - Annalisa Tassoni
- Department of Biological, Geological and Environmental Sciences, University of Bologna, Bologna, Italy
| | - Maura Ferri
- Department of Biological, Geological and Environmental Sciences, University of Bologna, Bologna, Italy; Department of Civil, Chemical Environmental and Materials Engineering, University of Bologna, Bologna, Italy
| | - Maria Maddalena Calabretta
- Department of Chemistry "Giacomo Ciamician", University of Bologna, Via Selmi 2, 40126, Bologna, Italy; Center for Applied Biomedical Research (CRBA), Azienda Ospedaliero-Universitaria Policlinico S. Orsola-Malpighi, Bologna, Italy.
| | - Elisa Michelini
- Department of Chemistry "Giacomo Ciamician", University of Bologna, Via Selmi 2, 40126, Bologna, Italy; Center for Applied Biomedical Research (CRBA), Azienda Ospedaliero-Universitaria Policlinico S. Orsola-Malpighi, Bologna, Italy; Health Sciences and Technologies-Interdepartmental Center for Industrial Research (HST-ICIR), University of Bologna, Bologna, Italy.
| |
Collapse
|
39
|
Ahmed A, Ahmad A, Li R, AL-Ansi W, Fatima M, Mushtaq BS, Basharat S, Li Y, Bai Z. Recent Advances in Synthetic, Industrial and Biological Applications of Violacein and Its Heterologous Production. J Microbiol Biotechnol 2021; 31:1465-1480. [PMID: 34584039 PMCID: PMC9705886 DOI: 10.4014/jmb.2107.07045] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2021] [Revised: 09/15/2021] [Accepted: 09/26/2021] [Indexed: 12/15/2022]
Abstract
Violacein, a purple pigment first isolated from a gram-negative coccobacillus Chromobacterium violaceum, has gained extensive research interest in recent years due to its huge potential in the pharmaceutic area and industry. In this review, we summarize the latest research advances concerning this pigment, which include (1) fundamental studies of its biosynthetic pathway, (2) production of violacein by native producers, apart from C. violaceum, (3) metabolic engineering for improved production in heterologous hosts such as Escherichia coli, Citrobacter freundii, Corynebacterium glutamicum, and Yarrowia lipolytica, (4) biological/pharmaceutical and industrial properties, (5) and applications in synthetic biology. Due to the intrinsic properties of violacein and the intermediates during its biosynthesis, the prospective research has huge potential to move this pigment into real clinical and industrial applications.
Collapse
Affiliation(s)
- Aqsa Ahmed
- School of Biotechnology, Jiangnan University, Wuxi 214122, P.R. China,National Engineering Laboratory for Cereal Fermentation Technology, Jiangnan University, Wuxi 214122, P.R. China
| | - Abdullah Ahmad
- Department of Industrial Biotechnology, Atta-Ur-Rahman School of Applied Biosciences, National University of Science and Technology, Islamabad 44000, Pakistan
| | - Renhan Li
- School of Biotechnology, Jiangnan University, Wuxi 214122, P.R. China,National Engineering Laboratory for Cereal Fermentation Technology, Jiangnan University, Wuxi 214122, P.R. China
| | - Waleed AL-Ansi
- School of Food Science and Technology, State Key Laboratory of Food Science and Technology, Jiangnan University, 1800 Lihu Avenue, Wuxi 214122, P.R. China,Department of Food Science and Technology, Faculty of Agriculture, Sana’a University, Sana’a, 725, Yemen
| | - Momal Fatima
- Department of Industrial Biotechnology, National Institute of Biotechnology and Genetic Engineering (NIBGE), Faisalabad 38000, Pakistan
| | - Bilal Sajid Mushtaq
- School of Food Science and Technology, State Key Laboratory of Food Science and Technology, Jiangnan University, 1800 Lihu Avenue, Wuxi 214122, P.R. China
| | - Samra Basharat
- School of Biotechnology, Jiangnan University, Wuxi 214122, P.R. China
| | - Ye Li
- School of Biotechnology, Jiangnan University, Wuxi 214122, P.R. China,National Engineering Laboratory for Cereal Fermentation Technology, Jiangnan University, Wuxi 214122, P.R. China,Corresponding authors Y. Li E-mail:
| | - Zhonghu Bai
- School of Biotechnology, Jiangnan University, Wuxi 214122, P.R. China,National Engineering Laboratory for Cereal Fermentation Technology, Jiangnan University, Wuxi 214122, P.R. China,
Z. Bai Phone: +86510-85197983 Fax: +86510-85197983 E-mail:
| |
Collapse
|
40
|
Wan X, Saltepe B, Yu L, Wang B. Programming living sensors for environment, health and biomanufacturing. Microb Biotechnol 2021; 14:2334-2342. [PMID: 33960658 PMCID: PMC8601174 DOI: 10.1111/1751-7915.13820] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2021] [Revised: 04/05/2021] [Accepted: 04/11/2021] [Indexed: 01/10/2023] Open
Abstract
Synthetic biology offers new tools and capabilities of engineering cells with desired functions for example as new biosensing platforms leveraging engineered microbes. In the last two decades, bacterial cells have been programmed to sense and respond to various input cues for versatile purposes including environmental monitoring, disease diagnosis and adaptive biomanufacturing. Despite demonstrated proof-of-concept success in the laboratory, the real-world applications of microbial sensors have been restricted due to certain technical and societal limitations. Yet, most limitations can be addressed by new technological developments in synthetic biology such as circuit design, biocontainment and machine learning. Here, we summarize the latest advances in synthetic biology and discuss how they could accelerate the development, enhance the performance and address the present limitations of microbial sensors to facilitate their use in the field. We view that programmable living sensors are promising sensing platforms to achieve sustainable, affordable and easy-to-use on-site detection in diverse settings.
Collapse
Affiliation(s)
- Xinyi Wan
- Centre for Synthetic and Systems BiologySchool of Biological SciencesUniversity of EdinburghEdinburghEH9 3FFUK
- Hangzhou Innovation CenterZhejiang UniversityHangzhou311200China
| | - Behide Saltepe
- Centre for Synthetic and Systems BiologySchool of Biological SciencesUniversity of EdinburghEdinburghEH9 3FFUK
| | - Luyang Yu
- The Provincial International Science and Technology Cooperation Base for Engineering BiologyInternational CampusZhejiang UniversityHaining314400China
- College of Life SciencesZhejiang UniversityHangzhou310058China
| | - Baojun Wang
- Centre for Synthetic and Systems BiologySchool of Biological SciencesUniversity of EdinburghEdinburghEH9 3FFUK
- Hangzhou Innovation CenterZhejiang UniversityHangzhou311200China
- The Provincial International Science and Technology Cooperation Base for Engineering BiologyInternational CampusZhejiang UniversityHaining314400China
- College of Life SciencesZhejiang UniversityHangzhou310058China
| |
Collapse
|
41
|
Moraskie M, Roshid MHO, O'Connor G, Dikici E, Zingg JM, Deo S, Daunert S. Microbial whole-cell biosensors: Current applications, challenges, and future perspectives. Biosens Bioelectron 2021; 191:113359. [PMID: 34098470 PMCID: PMC8376793 DOI: 10.1016/j.bios.2021.113359] [Citation(s) in RCA: 46] [Impact Index Per Article: 15.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2021] [Revised: 05/13/2021] [Accepted: 05/15/2021] [Indexed: 12/22/2022]
Abstract
Microbial Whole-Cell Biosensors (MWCBs) have seen rapid development with the arrival of 21st century biological and technological capabilities. They consist of microbial species which produce, or limit the production of, a reporter protein in the presence of a target analyte. The quantifiable signal from the reporter protein can be used to determine the bioavailable levels of the target analyte in a variety of sample types at a significantly lower cost than most widely used and well-established analytical instrumentation. Furthermore, the versatile and robust nature of MWCBs shows great potential for their use in otherwise unavailable settings and environments. While MWCBs have been developed for use in biomedical, environmental, and agricultural monitoring, they still face various challenges before they can transition from the laboratory into industrialized settings like their enzyme-based counterparts. In this comprehensive and critical review, we describe the underlying working principles of MWCBs, highlight developments for their use in a variety of fields, detail challenges and current efforts to address them, and discuss exciting implementations of MWCBs helping redefine what is thought to be possible with this expeditiously evolving technology.
Collapse
Affiliation(s)
- Michael Moraskie
- Department of Biochemistry and Molecular Biology, University of Miami Miller School of Medicine, Miami, FL, 33136, USA; The Dr. John T. Macdonald Foundation Biomedical Nanotechnology Institute - BioNIUM, University of Miami, Miami, FL, 33136, USA
| | - Md Harun Or Roshid
- Department of Biochemistry and Molecular Biology, University of Miami Miller School of Medicine, Miami, FL, 33136, USA; The Dr. John T. Macdonald Foundation Biomedical Nanotechnology Institute - BioNIUM, University of Miami, Miami, FL, 33136, USA; Department of Chemistry, University of Miami, Miami, FL, 33146, USA
| | - Gregory O'Connor
- Department of Biochemistry and Molecular Biology, University of Miami Miller School of Medicine, Miami, FL, 33136, USA; The Dr. John T. Macdonald Foundation Biomedical Nanotechnology Institute - BioNIUM, University of Miami, Miami, FL, 33136, USA
| | - Emre Dikici
- Department of Biochemistry and Molecular Biology, University of Miami Miller School of Medicine, Miami, FL, 33136, USA; The Dr. John T. Macdonald Foundation Biomedical Nanotechnology Institute - BioNIUM, University of Miami, Miami, FL, 33136, USA
| | - Jean-Marc Zingg
- Department of Biochemistry and Molecular Biology, University of Miami Miller School of Medicine, Miami, FL, 33136, USA; The Dr. John T. Macdonald Foundation Biomedical Nanotechnology Institute - BioNIUM, University of Miami, Miami, FL, 33136, USA
| | - Sapna Deo
- Department of Biochemistry and Molecular Biology, University of Miami Miller School of Medicine, Miami, FL, 33136, USA; The Dr. John T. Macdonald Foundation Biomedical Nanotechnology Institute - BioNIUM, University of Miami, Miami, FL, 33136, USA
| | - Sylvia Daunert
- Department of Biochemistry and Molecular Biology, University of Miami Miller School of Medicine, Miami, FL, 33136, USA; The Dr. John T. Macdonald Foundation Biomedical Nanotechnology Institute - BioNIUM, University of Miami, Miami, FL, 33136, USA; Department of Chemistry, University of Miami, Miami, FL, 33146, USA; The Miami Clinical and Translational Science Institute, University of Miami, Miami, FL, 33146, USA; Sylvester Comprehensive Cancer Center, University of Miami, Miami, FL, 33146, USA.
| |
Collapse
|
42
|
Rutter JW, Dekker L, Fedorec AJH, Gonzales DT, Wen KY, Tanner LES, Donovan E, Ozdemir T, Thomas GM, Barnes CP. Engineered acetoacetate-inducible whole-cell biosensors based on the AtoSC two-component system. Biotechnol Bioeng 2021; 118:4278-4289. [PMID: 34289076 DOI: 10.1002/bit.27897] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2021] [Revised: 07/09/2021] [Accepted: 07/09/2021] [Indexed: 11/12/2022]
Abstract
Whole-cell biosensors hold potential in a variety of industrial, medical, and environmental applications. These biosensors can be constructed through the repurposing of bacterial sensing mechanisms, including the common two-component system (TCS). Here we report on the construction of a range of novel biosensors that are sensitive to acetoacetate, a molecule that plays a number of roles in human health and biology. These biosensors are based on the AtoSC TCS. An ordinary differential equation model to describe the action of the AtoSC TCS was developed and sensitivity analysis of this model used to help inform biosensor design. The final collection of biosensors constructed displayed a range of switching behaviours at physiologically relevant acetoacetate concentrations and can operate in several Escherichia coli host strains. It is envisaged that these biosensor strains will offer an alternative to currently available commercial strip tests and, in future, may be adopted for more complex in vivo or industrial monitoring applications.
Collapse
Affiliation(s)
- Jack W Rutter
- Department of Cell and Developmental Biology, University College London, London, UK
| | - Linda Dekker
- Department of Cell and Developmental Biology, University College London, London, UK
| | - Alex J H Fedorec
- Department of Cell and Developmental Biology, University College London, London, UK
| | - David T Gonzales
- Department of Cell and Developmental Biology, University College London, London, UK
| | - Ke Yan Wen
- Department of Cell and Developmental Biology, University College London, London, UK
| | - Lewis E S Tanner
- Department of Cell and Developmental Biology, University College London, London, UK
| | - Emma Donovan
- Department of Cell and Developmental Biology, University College London, London, UK
| | - Tanel Ozdemir
- Department of Cell and Developmental Biology, University College London, London, UK
| | - Geraint M Thomas
- Department of Cell and Developmental Biology, University College London, London, UK
| | - Chris P Barnes
- Department of Cell and Developmental Biology, University College London, London, UK.,Department of Genetics, Evolution and Environment, University College London, London, UK
| |
Collapse
|
43
|
Calabretta M, Montali L, Lopreside A, Fragapane F, Iacoangeli F, Roda A, Bocci V, D’Elia M, Michelini E. Ultrasensitive On-Field Luminescence Detection Using a Low-Cost Silicon Photomultiplier Device. Anal Chem 2021; 93:7388-7393. [PMID: 33973781 PMCID: PMC8253476 DOI: 10.1021/acs.analchem.1c00899] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2021] [Accepted: 04/27/2021] [Indexed: 12/14/2022]
Abstract
The availability of portable analytical devices for on-site monitoring and rapid detection of analytes of forensic, environmental, and clinical interest is vital. We report the development of a portable device for the detection of biochemiluminescence relying on silicon photomultiplier (SiPM) technology, called LuminoSiPM, which includes a 3D printed sample holder that can be adapted for both liquid samples and paper-based biosensing. We performed a comparison of analytical performance in terms of detectability with a benchtop luminometer, a portable cooled charge-coupled device (CCD sensor), and smartphone-integrated complementary metal oxide semiconductor (CMOS) sensors. As model systems, we used two luciferase/luciferin systems emitting at different wavelengths using purified protein solutions: the green-emitting P. pyralis mutant Ppy-GR-TS (λmax 550 nm) and the blue-emitting NanoLuc (λmax 460 nm). A limit of detection of 9 femtomoles was obtained for NanoLuc luciferase, about 2 and 3 orders of magnitude lower than that obtained with the portable CCD camera and with the smartphone, respectively. A proof-of-principle forensic application of LuminoSiPM is provided, exploiting an origami chemiluminescent paper-based sensor for acetylcholinesterase inhibitors, showing high potential for this portable low-cost device for on-site applications with adequate sensitivity for detecting low light intensities in critical fields.
Collapse
Affiliation(s)
- Maria
Maddalena Calabretta
- Department
of Chemistry “Giacomo Ciamician”, University of Bologna, 40126 Bologna, Italy
- Center
for Applied Biomedical Research (CRBA), University of Bologna, 40126 Bologna, Italy
| | - Laura Montali
- Department
of Chemistry “Giacomo Ciamician”, University of Bologna, 40126 Bologna, Italy
- Center
for Applied Biomedical Research (CRBA), University of Bologna, 40126 Bologna, Italy
| | - Antonia Lopreside
- Department
of Chemistry “Giacomo Ciamician”, University of Bologna, 40126 Bologna, Italy
- Center
for Applied Biomedical Research (CRBA), University of Bologna, 40126 Bologna, Italy
| | - Fabio Fragapane
- Gabinetto
Regionale di Polizia Scientifica per l’Emilia-Romagna, 40123, Bologna, Italy
| | | | - Aldo Roda
- Department
of Chemistry “Giacomo Ciamician”, University of Bologna, 40126 Bologna, Italy
- INBB, Istituto
Nazionale di Biostrutture e Biosistemi, 00136 Rome, Italy
| | - Valerio Bocci
- INFN,
Istituto Nazionale di Fisica Nucleare Sezione di Roma, 00185 Rome, Italy
| | - Marcello D’Elia
- Gabinetto
Regionale di Polizia Scientifica per l’Emilia-Romagna, 40123, Bologna, Italy
| | - Elisa Michelini
- Department
of Chemistry “Giacomo Ciamician”, University of Bologna, 40126 Bologna, Italy
- Center
for Applied Biomedical Research (CRBA), University of Bologna, 40126 Bologna, Italy
- INBB, Istituto
Nazionale di Biostrutture e Biosistemi, 00136 Rome, Italy
- Health
Sciences and Technologies-Interdepartmental Center for Industrial
Research (HST-ICIR), University of Bologna, 40126 Bologna, Italy
| |
Collapse
|
44
|
Tan SI, Ng IS. CRISPRi-Mediated NIMPLY Logic Gate for Fine-Tuning the Whole-Cell Sensing toward Simple Urine Glucose Detection. ACS Synth Biol 2021; 10:412-421. [PMID: 33560108 DOI: 10.1021/acssynbio.1c00014] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Abstract
Whole-cell biosensors have been regarded as a prominent alternative to chemical and physical biosensors due to their renewability, environmental friendliness, and biocompatibility. However, there is still a lack of noninvasive measurements of urine glucose, which plays a vital role in monitoring the risk of diabetes in the healthcare system, via whole-cell biosensors. In this study, we characterized a glucose-inducible promoter and further enhanced the sensing performance using three genetic effectors, which encompassed ribozyme regulator (RiboJ), clustered regularly interspaced short palindromic repeat interference (CRISPRi), and plasmid-based T7RNA polymerase (PDT7), to develop the noninvasive glucose biosensor by fluorescent signal. As a result, RiboJ increased dynamic range to 2989 au, but declined signal-to-noise (S/N) to 1.59, while CRISPRi-mediated NIMPLY gate intensified both dynamic range to 5720 au and S/N to 4.58. The use of single PDT7 orthogonal with T7 promoter in cells (i.e., P strain) achieved a 44 180 au of dynamic range with S/N at 3.08. By coupling the PDT7 and NIMPLY-mediated CRISPRi, we constructed an optimum PIGAS strain with the highest S/N value of 4.95. Finally, we adopted the synthetic bacteria into a microdevice to afford an integrative and portable system for daily urine glucose inspection, which would be an alternative approach for medical diagnosis in the future.
Collapse
Affiliation(s)
- Shih-I Tan
- Department of Chemical Engineering, National Cheng Kung University, Tainan 701, Taiwan
| | - I-Son Ng
- Department of Chemical Engineering, National Cheng Kung University, Tainan 701, Taiwan
| |
Collapse
|
45
|
Wang X, Zhu K, Chen D, Wang J, Wang X, Xu A, Wu L, Li L, Chen S. Monitoring arsenic using genetically encoded biosensors in vitro: The role of evolved regulatory genes. ECOTOXICOLOGY AND ENVIRONMENTAL SAFETY 2021; 207:111273. [PMID: 32916524 DOI: 10.1016/j.ecoenv.2020.111273] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/18/2020] [Revised: 08/31/2020] [Accepted: 09/01/2020] [Indexed: 06/11/2023]
Abstract
Toxic pollutant (TP) detection in situ using analytical instruments or whole-cell biosensors is inconvenient. Designing and developing genetically coded biosensors in vitro for real-world TP detection is a promising alternative. However, because the bioactivity and stability of some key biomolecules are weakened in vitro, the response and regulation of reporter protein become difficult. Here, we established a genetically encoded biosensor in vitro with an arsenical resistance operon repressor (ArsR) and GFP reporter gene. Given that the wildtype ArsR did not respond to arsenic and activate GFP expression in vitro, we found, after screening, an evolved ArsR mutant ep3 could respond to arsenic and exhibited an approximately 3.4-fold fluorescence increase. Arsenic induced expression of both wildtype ArsR and ep3 mutant in vitro, however, only ep3 mutant regulated the expression of reporter gene. Furthermore, the effects of cell extracts, temperature, pH, incubation, and equilibrium time were investigated, and the equilibration of reaction mixtures for 30 min at 37 °C was found to be essential for in vitro arsenic detection prior to treatment with arsenic. Based on our data, we established a standard procedure for arsenic detection in vitro. Our results will facilitate the practical application of genetically encoded biosensors in TP monitoring.
Collapse
Affiliation(s)
- Xuanyu Wang
- Key Laboratory of High Magnetic Field and Ion Beam Physical Biology, Hefei Institutes of Physical Science, China Academy of Sciences, Hefei, Anhui, 230031, China; University of Science and Technology of China, Hefei, Anhui, 230026, China; Key Laboratory of Environmental Toxicology and Pollution Control Technology of Anhui Province, Hefei, Anhui, 230031, China
| | - Kaili Zhu
- Key Laboratory of High Magnetic Field and Ion Beam Physical Biology, Hefei Institutes of Physical Science, China Academy of Sciences, Hefei, Anhui, 230031, China; University of Science and Technology of China, Hefei, Anhui, 230026, China; Key Laboratory of Environmental Toxicology and Pollution Control Technology of Anhui Province, Hefei, Anhui, 230031, China
| | - Dongdong Chen
- Institute of Physical Science and Information Technology, Anhui University, Hefei, Anhui, 230601, China
| | - Juan Wang
- Key Laboratory of High Magnetic Field and Ion Beam Physical Biology, Hefei Institutes of Physical Science, China Academy of Sciences, Hefei, Anhui, 230031, China; University of Science and Technology of China, Hefei, Anhui, 230026, China; Key Laboratory of Environmental Toxicology and Pollution Control Technology of Anhui Province, Hefei, Anhui, 230031, China
| | - Xiaofei Wang
- School of Biology, Food and Environment, Hefei University, Hefei, Anhui, 230601, China
| | - An Xu
- Key Laboratory of High Magnetic Field and Ion Beam Physical Biology, Hefei Institutes of Physical Science, China Academy of Sciences, Hefei, Anhui, 230031, China; University of Science and Technology of China, Hefei, Anhui, 230026, China; Key Laboratory of Environmental Toxicology and Pollution Control Technology of Anhui Province, Hefei, Anhui, 230031, China
| | - Lijun Wu
- Key Laboratory of High Magnetic Field and Ion Beam Physical Biology, Hefei Institutes of Physical Science, China Academy of Sciences, Hefei, Anhui, 230031, China; University of Science and Technology of China, Hefei, Anhui, 230026, China; Key Laboratory of Environmental Toxicology and Pollution Control Technology of Anhui Province, Hefei, Anhui, 230031, China; Institute of Physical Science and Information Technology, Anhui University, Hefei, Anhui, 230601, China
| | - Luzhi Li
- School of Biology, Food and Environment, Hefei University, Hefei, Anhui, 230601, China
| | - Shaopeng Chen
- Key Laboratory of High Magnetic Field and Ion Beam Physical Biology, Hefei Institutes of Physical Science, China Academy of Sciences, Hefei, Anhui, 230031, China; Key Laboratory of Environmental Toxicology and Pollution Control Technology of Anhui Province, Hefei, Anhui, 230031, China.
| |
Collapse
|
46
|
Lopreside A, Calabretta MM, Montali L, Zangheri M, Guardigli M, Mirasoli M, Michelini E. Bioluminescence goes portable: recent advances in whole-cell and cell-free bioluminescence biosensors. LUMINESCENCE 2020; 36:278-293. [PMID: 32945075 DOI: 10.1002/bio.3948] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2020] [Revised: 09/03/2020] [Accepted: 09/07/2020] [Indexed: 12/24/2022]
Abstract
Recent advancements in synthetic biology, organic chemistry, and computational models have allowed the application of bioluminescence in several fields, ranging from well established methods for detecting microbial contamination to in vivo imaging to track cancer and stem cells, from cell-based assays to optogenetics. Moreover, thanks to recent technological progress in miniaturized and sensitive light detectors, such as photodiodes and imaging sensors, it is possible to implement laboratory-based assays, such as cell-based and enzymatic assays, into portable analytical devices for point-of-care and on-site applications. This review highlights some recent advances in the development of whole-cell and cell-free bioluminescence biosensors with a glance on current challenges and different strategies that have been used to turn bioassays into biosensors with the required analytical performance. Critical issues and unsolved technical problems are also highlighted, to give the reader a taste of this fascinating and challenging field.
Collapse
Affiliation(s)
- Antonia Lopreside
- Department of Chemistry 'Giacomo Ciamician', University of Bologna, Via Selmi 2, Bologna, Italy
| | | | - Laura Montali
- Department of Chemistry 'Giacomo Ciamician', University of Bologna, Via Selmi 2, Bologna, Italy
| | - Martina Zangheri
- Department of Chemistry 'Giacomo Ciamician', University of Bologna, Via Selmi 2, Bologna, Italy
| | - Massimo Guardigli
- Department of Chemistry 'Giacomo Ciamician', University of Bologna, Via Selmi 2, Bologna, Italy.,Interdepartmental Centre for Renewable Sources, Environment, Sea and Energy (CIRI FRAME), Alma Mater Studiorum - University of Bologna, Via Sant'Alberto 163, Ravenna, Italy
| | - Mara Mirasoli
- Department of Chemistry 'Giacomo Ciamician', University of Bologna, Via Selmi 2, Bologna, Italy.,Interdepartmental Centre for Renewable Sources, Environment, Sea and Energy (CIRI FRAME), Alma Mater Studiorum - University of Bologna, Via Sant'Alberto 163, Ravenna, Italy.,INBB, Istituto Nazionale di Biostrutture e Biosistemi, Via Medaglie d'Oro, Rome, Italy
| | - Elisa Michelini
- Department of Chemistry 'Giacomo Ciamician', University of Bologna, Via Selmi 2, Bologna, Italy.,Interdepartmental Centre for Renewable Sources, Environment, Sea and Energy (CIRI FRAME), Alma Mater Studiorum - University of Bologna, Via Sant'Alberto 163, Ravenna, Italy.,Health Sciences and Technologies-Interdepartmental Centre for Industrial Research (HST-ICIR), University of Bologna, via Tolara di Sopra 41/E 40064, Ozzano dell'Emilia, Bologna, Italy
| |
Collapse
|
47
|
Qin Y, Wu G, Guo Y, Ke D, Yin J, Wang D, Fan X, Liu Z, Ruan L, Hu Y. Engineered glyphosate oxidase coupled to spore-based chemiluminescence system for glyphosate detection. Anal Chim Acta 2020; 1133:39-47. [PMID: 32993872 DOI: 10.1016/j.aca.2020.07.077] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2020] [Revised: 07/29/2020] [Accepted: 07/30/2020] [Indexed: 10/23/2022]
Abstract
The extensive and intensive utilization of glyphosate (Glyp) caused public concerns on the potential risk of environment and health resulted from the chemical residues. Therefore, the development of a high-selective, low-cost and easy-operation Glyp detection methods is highly desired. Screening highly selective enzymes by directed evolution is important in practical applications. Herein, a glyphosate oxidase (GlypO) preferring substrate Glyp to produce H2O2 was obtained via directed evolution from glycine oxidase obtained from Bacillus cereus (BceGO). The catalytic efficiency, specificity constant, and affinity enhancement factor of GlypO toward Glyp were increased by 2.85 × 103-fold; 2.25 × 105-fold; and 9.64 × 104-fold, respectively, compared with those of BceGO. The catalytic efficiency toward glycine decreased by 78.60-fold. The spores of Bacillus subtilis (B. subtilis) effectively catalyzed luminol-H2O2 reaction to create excellent chemiluminescence (CL) signal because CotA-laccase exists on their surface. Based on these findings, a new CL biosensor via coupling to biological reaction system was presented for Glyp detection. The CL biosensor exhibited several advantages, such as eco-friendliness, low cost, high selectivity and sensitivity, and good practical application prospects for environmental pollution control.
Collapse
Affiliation(s)
- Yuqing Qin
- State Key Laboratory of Agricultural Microbiology, Huazhong Agricultural University, Wuhan, 430070, China; College of Life Science and Technology, Huazhong Agricultural University, Wuhan, 430070, China
| | - Gaobing Wu
- State Key Laboratory of Agricultural Microbiology, Huazhong Agricultural University, Wuhan, 430070, China; College of Plant Science and Technology, Huazhong Agricultural University, Wuhan, 430070, China
| | - Yiming Guo
- College of Life Science and Technology, Huazhong Agricultural University, Wuhan, 430070, China
| | - Da Ke
- College of Plant Science and Technology, Huazhong Agricultural University, Wuhan, 430070, China
| | - Jiakang Yin
- State Key Laboratory of Agricultural Microbiology, Huazhong Agricultural University, Wuhan, 430070, China; College of Life Science and Technology, Huazhong Agricultural University, Wuhan, 430070, China
| | - Donglin Wang
- College of Life Science and Technology, Huazhong Agricultural University, Wuhan, 430070, China
| | - Xuezhu Fan
- State Key Laboratory of Agricultural Microbiology, Huazhong Agricultural University, Wuhan, 430070, China; College of Life Science and Technology, Huazhong Agricultural University, Wuhan, 430070, China
| | - Ziduo Liu
- College of Life Science and Technology, Huazhong Agricultural University, Wuhan, 430070, China
| | - Lifang Ruan
- State Key Laboratory of Agricultural Microbiology, Huazhong Agricultural University, Wuhan, 430070, China; College of Life Science and Technology, Huazhong Agricultural University, Wuhan, 430070, China.
| | - Yonggang Hu
- State Key Laboratory of Agricultural Microbiology, Huazhong Agricultural University, Wuhan, 430070, China; College of Life Science and Technology, Huazhong Agricultural University, Wuhan, 430070, China.
| |
Collapse
|
48
|
Recent advances in synthetic biology-enabled and natural whole-cell optical biosensing of heavy metals. Anal Bioanal Chem 2020; 413:73-82. [PMID: 32959111 DOI: 10.1007/s00216-020-02953-6] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2020] [Revised: 09/08/2020] [Accepted: 09/11/2020] [Indexed: 10/23/2022]
Abstract
A large number of scientific works have been published on whole-cell heavy metal biosensing based on optical transduction. The advances in the application of biotechnological tools not only have continuously improved the sensitivity, selectivity, and detection range for biosensors but also have simultaneously unveiled new challenges and restrictions for further improvements. This review highlights selected aspects of whole-cell biosensing of heavy metals using optical transducers. We have focused on the progress in genetic modulation in regulatory and reporter modules of recombinant plasmids that has enabled improvement of biosensor performance. Simultaneously, an attempt has been made to present newer platforms such as microfluidics that have generated promising results and might give a new turn to the optical biosensing field.
Collapse
|
49
|
Zhang L, Guo W, Lu Y. Advances in Cell‐Free Biosensors: Principle, Mechanism, and Applications. Biotechnol J 2020; 15:e2000187. [DOI: 10.1002/biot.202000187] [Citation(s) in RCA: 26] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2020] [Revised: 06/22/2020] [Indexed: 12/17/2022]
Affiliation(s)
- Liyuan Zhang
- Key Laboratory of Industrial Biocatalysis Ministry of Education Department of Chemical Engineering Tsinghua University Beijing 100084 China
- Department of Ecology Shenyang Agricultural University Shenyang Liaoning Province 110866 China
| | - Wei Guo
- Department of Ecology Shenyang Agricultural University Shenyang Liaoning Province 110866 China
| | - Yuan Lu
- Key Laboratory of Industrial Biocatalysis Ministry of Education Department of Chemical Engineering Tsinghua University Beijing 100084 China
| |
Collapse
|
50
|
Shemer B, Shpigel E, Glozman A, Yagur-Kroll S, Kabessa Y, Agranat AJ, Belkin S. Genome-wide gene-deletion screening identifies mutations that significantly enhance explosives vapor detection by a microbial sensor. N Biotechnol 2020; 59:65-73. [PMID: 32622861 DOI: 10.1016/j.nbt.2020.06.002] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2020] [Revised: 06/25/2020] [Accepted: 06/26/2020] [Indexed: 12/16/2022]
Abstract
Genetically engineered microbial biosensors, capable of detecting traces of explosives residues above buried military ordnance and emitting an optical signal in response, may potentially serve for the standoff detection of buried landmines. A promising candidate for such an application is a previously reported Escherichia coli-based reporter strain that employs the yqjF gene promoter as its sensing element; however, for this sensor to be able to detect actual landmines reliably, it was necessary for its detection sensitivity and signal intensity to be enhanced. In this study, a high-throughput approach was employed to screen the effects of individual gene deletions on yqjF activation by 2,4-dinitrotoluene (DNT). Several genes were identified, the deletion of which elicited a significant enhancement of yqjF induction by DNT. The most promising of these mutations were introduced into the sensor strain, individually or in pairs, yielding a considerable increase in signal intensity and a lowering of the detection threshold. A strain harboring two of the identified mutations, ygdD and eutE, appears to be the most sensitive microbial biosensor currently described for the detection of traces of landmine explosives.
Collapse
Affiliation(s)
- Benjamin Shemer
- Department of Plant and Environmental Sciences, Institute of Life Sciences, The Hebrew University of Jerusalem, Israel
| | - Etai Shpigel
- Department of Plant and Environmental Sciences, Institute of Life Sciences, The Hebrew University of Jerusalem, Israel
| | - Anat Glozman
- Department of Plant and Environmental Sciences, Institute of Life Sciences, The Hebrew University of Jerusalem, Israel
| | - Sharon Yagur-Kroll
- Department of Plant and Environmental Sciences, Institute of Life Sciences, The Hebrew University of Jerusalem, Israel
| | - Yosssef Kabessa
- Department of Applied Physics and the Brojde Center for Innovative Engineering and Computer Science, The Hebrew University of Jerusalem, Israel
| | - Aharon J Agranat
- Department of Applied Physics and the Brojde Center for Innovative Engineering and Computer Science, The Hebrew University of Jerusalem, Israel
| | - Shimshon Belkin
- Department of Plant and Environmental Sciences, Institute of Life Sciences, The Hebrew University of Jerusalem, Israel.
| |
Collapse
|