1
|
Guan S, Li J, Wang Y, Yang Y, Zhu X, Ye D, Chen R, Liao Q. Multifunctional MOF-Derived Au, Co-Doped Porous Carbon Electrode for a Wearable Sweat Energy Harvesting-Storage Hybrid System. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2023; 35:e2304465. [PMID: 37318943 DOI: 10.1002/adma.202304465] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/11/2023] [Revised: 06/14/2023] [Indexed: 06/17/2023]
Abstract
As an efficient alternative for harnessing the energy from human's biofluid, a wearable energy harvesting-storage hybrid supercapacitor-biofuel cell (SC-BFC) microfluidic system is established with one multifunctional electrode. The electrode integrates metal-organic framework (MOF) derived carbon nanoarrays with embedded Au, Co nanoparticles on a flexible substrate, and is used for the symmetric supercapacitor as well as the enzyme nanocarriers of the biofuel cell. The electrochemical performance of the proposed electrode is evaluated, and the corresponding working mechanism is studied in depth according to the cyclic voltammetry and density functional theory calculation. The multiplexed microfluidic system is designed to pump and store natural sweat to maintain the continuous biofuel supply in the hybrid SC-BFC system. The biofuel cell module harvests electricity from lactate in sweat, and the symmetric supercapacitor module accommodates the bioelectricity for subsequent utilization. A numerical model is developed to validate the normal operation in poor and rich sweat under variable situations for the microfluidic system. One single SC-BFC unit can be self-charged to ≈0.8 V with superior mechanical durability in on-body testing, as well as energy and power values of 7.2 mJ and 80.3 µW, respectively. It illustrates the promising scenery of energy harvesting-storage hybrid microfluidic system.
Collapse
Affiliation(s)
- Shoujie Guan
- Key Laboratory of Low-grade Energy Utilization Technologies and Systems, Ministry of Education, Chongqing University, Chongqing, 400030, China
- Institute of Engineering Thermophysics, School of Energy and Powering Engineering, Chongqing University, Chongqing, 400030, China
| | - Jiaxuan Li
- Key Laboratory of Low-grade Energy Utilization Technologies and Systems, Ministry of Education, Chongqing University, Chongqing, 400030, China
- Institute of Engineering Thermophysics, School of Energy and Powering Engineering, Chongqing University, Chongqing, 400030, China
| | - Yuyang Wang
- Key Laboratory of Low-grade Energy Utilization Technologies and Systems, Ministry of Education, Chongqing University, Chongqing, 400030, China
- Institute of Engineering Thermophysics, School of Energy and Powering Engineering, Chongqing University, Chongqing, 400030, China
| | - Yang Yang
- Key Laboratory of Low-grade Energy Utilization Technologies and Systems, Ministry of Education, Chongqing University, Chongqing, 400030, China
- Institute of Engineering Thermophysics, School of Energy and Powering Engineering, Chongqing University, Chongqing, 400030, China
| | - Xun Zhu
- Key Laboratory of Low-grade Energy Utilization Technologies and Systems, Ministry of Education, Chongqing University, Chongqing, 400030, China
- Institute of Engineering Thermophysics, School of Energy and Powering Engineering, Chongqing University, Chongqing, 400030, China
| | - Dingding Ye
- Key Laboratory of Low-grade Energy Utilization Technologies and Systems, Ministry of Education, Chongqing University, Chongqing, 400030, China
- Institute of Engineering Thermophysics, School of Energy and Powering Engineering, Chongqing University, Chongqing, 400030, China
| | - Rong Chen
- Key Laboratory of Low-grade Energy Utilization Technologies and Systems, Ministry of Education, Chongqing University, Chongqing, 400030, China
- Institute of Engineering Thermophysics, School of Energy and Powering Engineering, Chongqing University, Chongqing, 400030, China
| | - Qiang Liao
- Key Laboratory of Low-grade Energy Utilization Technologies and Systems, Ministry of Education, Chongqing University, Chongqing, 400030, China
- Institute of Engineering Thermophysics, School of Energy and Powering Engineering, Chongqing University, Chongqing, 400030, China
| |
Collapse
|
2
|
Huang W, Zulkifli MYB, Chai M, Lin R, Wang J, Chen Y, Chen V, Hou J. Recent advances in enzymatic biofuel cells enabled by innovative materials and techniques. EXPLORATION (BEIJING, CHINA) 2023; 3:20220145. [PMID: 37933234 PMCID: PMC10624391 DOI: 10.1002/exp.20220145] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/12/2022] [Accepted: 03/21/2023] [Indexed: 11/08/2023]
Abstract
The past few decades have seen increasingly rapid advances in the field of sustainable energy technologies. As a new bio- and eco-friendly energy source, enzymatic biofuel cells (EBFCs) have garnered significant research interest due to their capacity to power implantable bioelectronics, portable devices, and biosensors by utilizing biomass as fuel under mild circumstances. Nonetheless, numerous obstacles impeded the commercialization of EBFCs, including their relatively modest power output and poor long-term stability of enzymes. To depict the current progress of EBFC and address the challenges it faces, this review traces back the evolution of EBFC and focuses on contemporary advances such as newly emerged multi or single enzyme systems, various porous framework-enzyme composites techniques, and innovative applications. Besides emphasizing current achievements in this field, from our perspective part we also introduced novel electrode and cell design for highly effective EBFC fabrication. We believe this review will assist readers in comprehending the basic research and applications of EBFCs as well as potentially spark interdisciplinary collaboration for addressing the pressing issues in this field.
Collapse
Affiliation(s)
- Wengang Huang
- School of Chemical EngineeringThe University of QueenslandSaint LuciaQueenslandAustralia
| | - Muhammad Yazid Bin Zulkifli
- School of Chemical EngineeringThe University of QueenslandSaint LuciaQueenslandAustralia
- School of Chemical EngineeringThe University of New South WalesSydneyNew South WalesAustralia
| | - Milton Chai
- School of Chemical EngineeringThe University of QueenslandSaint LuciaQueenslandAustralia
| | - Rijia Lin
- School of Chemical EngineeringThe University of QueenslandSaint LuciaQueenslandAustralia
| | - Jingjing Wang
- Australian Institute for Bioengineering and NanotechnologyThe University of QueenslandSaint LuciaQueenslandAustralia
| | - Yuelei Chen
- School of Chemical EngineeringThe University of QueenslandSaint LuciaQueenslandAustralia
| | - Vicki Chen
- School of Chemical EngineeringThe University of QueenslandSaint LuciaQueenslandAustralia
| | - Jingwei Hou
- School of Chemical EngineeringThe University of QueenslandSaint LuciaQueenslandAustralia
| |
Collapse
|
3
|
Wittstock G, Bäumer M, Dononelli W, Klüner T, Lührs L, Mahr C, Moskaleva LV, Oezaslan M, Risse T, Rosenauer A, Staubitz A, Weissmüller J, Wittstock A. Nanoporous Gold: From Structure Evolution to Functional Properties in Catalysis and Electrochemistry. Chem Rev 2023; 123:6716-6792. [PMID: 37133401 PMCID: PMC10214458 DOI: 10.1021/acs.chemrev.2c00751] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2022] [Indexed: 05/04/2023]
Abstract
Nanoporous gold (NPG) is characterized by a bicontinuous network of nanometer-sized metallic struts and interconnected pores formed spontaneously by oxidative dissolution of the less noble element from gold alloys. The resulting material exhibits decent catalytic activity for low-temperature, aerobic total as well as partial oxidation reactions, the oxidative coupling of methanol to methyl formate being the prototypical example. This review not only provides a critical discussion of ways to tune the morphology and composition of this material and its implication for catalysis and electrocatalysis, but will also exemplarily review the current mechanistic understanding of the partial oxidation of methanol using information from quantum chemical studies, model studies on single-crystal surfaces, gas phase catalysis, aerobic liquid phase oxidation, and electrocatalysis. In this respect, a particular focus will be on mechanistic aspects not well understood, yet. Apart from the mechanistic aspects of catalysis, best practice examples with respect to material preparation and characterization will be discussed. These can improve the reproducibility of the materials property such as the catalytic activity and selectivity as well as the scope of reactions being identified as the main challenges for a broader application of NPG in target-oriented organic synthesis.
Collapse
Affiliation(s)
- Gunther Wittstock
- Carl
von Ossietzky University of Oldenburg, School of Mathematics and Science, Institute of Chemistry, D-26111 Oldenburg, Germany
| | - Marcus Bäumer
- University
of Bremen, Institute for Applied
and Physical Chemistry, 28359 Bremen, Germany
- University
of Bremen, MAPEX Center for
Materials and Processes, 28359 Bremen, Germany
| | - Wilke Dononelli
- University
of Bremen, MAPEX Center for
Materials and Processes, 28359 Bremen, Germany
- University
of Bremen, Bremen Center for
Computational Materials Science, Hybrid Materials Interfaces Group, Am Fallturm 1, Bremen 28359, Germany
| | - Thorsten Klüner
- Carl
von Ossietzky University of Oldenburg, School of Mathematics and Science, Institute of Chemistry, D-26111 Oldenburg, Germany
| | - Lukas Lührs
- Hamburg
University of Technology, Institute of Materials
Physics and Technology, 21703 Hamburg, Germany
| | - Christoph Mahr
- University
of Bremen, MAPEX Center for
Materials and Processes, 28359 Bremen, Germany
- University
of Bremen, Institute of Solid
State Physics, Otto Hahn
Allee 1, 28359 Bremen, Germany
| | - Lyudmila V. Moskaleva
- University
of the Free State, Department of Chemistry, P.O. Box 339, Bloemfontein 9300, South Africa
| | - Mehtap Oezaslan
- Technical
University of Braunschweig Institute of Technical Chemistry, Technical Electrocatalysis Laboratory, Franz-Liszt-Strasse 35a, 38106 Braunschweig, Germany
| | - Thomas Risse
- Freie
Universität Berlin, Institute of Chemistry
and Biochemistry, Arnimallee
22, 14195 Berlin, Germany
| | - Andreas Rosenauer
- University
of Bremen, MAPEX Center for
Materials and Processes, 28359 Bremen, Germany
- University
of Bremen, Institute of Solid
State Physics, Otto Hahn
Allee 1, 28359 Bremen, Germany
| | - Anne Staubitz
- University
of Bremen, MAPEX Center for
Materials and Processes, 28359 Bremen, Germany
- University
of Bremen, Institute for Organic
and Analytical Chemistry, Leobener Strasse 7, D-28359 Bremen, Germany
| | - Jörg Weissmüller
- Hamburg
University of Technology, Institute of Materials
Physics and Technology, 21703 Hamburg, Germany
- Helmholtz-Zentrum
Hereon, Institute of Materials Mechanics, 21502 Geesthacht, Germany
| | - Arne Wittstock
- University
of Bremen, MAPEX Center for
Materials and Processes, 28359 Bremen, Germany
- University
of Bremen, Institute for Organic
and Analytical Chemistry, Leobener Strasse 7, D-28359 Bremen, Germany
| |
Collapse
|
4
|
Feng X, Ning Y, Wu Z, Li Z, Xu C, Li G, Hu Z. Defect-Enriched Graphene Nanoribbons Tune the Adsorption Behavior of the Mediator to Boost the Lactate/Oxygen Biofuel Cell. NANOMATERIALS (BASEL, SWITZERLAND) 2023; 13:1089. [PMID: 36985983 PMCID: PMC10058110 DOI: 10.3390/nano13061089] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/18/2023] [Revised: 03/11/2023] [Accepted: 03/14/2023] [Indexed: 06/18/2023]
Abstract
Owing to the high efficiency and specificity in moderate conditions, enzymatic biofuel cells (EBFCs) have gained significant interest as a promising energy source for wearable devices. However, the instability of the bioelectrode and the lack of efficient electrical communication between the enzymes and electrodes are the main obstacles. Herein, defect-enriched 3D graphene nanoribbons (GNRs) frameworks are fabricated by unzipping multiwall carbon nanotubes, followed by thermal annealing. It is found that defective carbon shows stronger adsorption energy towards the polar mediators than the pristine carbon, which is beneficial to improving the stability of the bioelectrodes. Consequently, the EBFCs equipped with the GNRs exhibit a significantly enhanced bioelectrocatalytic performance and operational stability, delivering an open-circuit voltage and power density of 0.62 V, 70.7 μW/cm2, and 0.58 V, 18.6 μW/cm2 in phosphate buffer solution and artificial tear, respectively, which represent the high levels among the reported literature. This work provides a design principle according to which defective carbon materials could be more suitable for the immobilization of biocatalytic components in the application of EBFCs.
Collapse
Affiliation(s)
- Xiaoyu Feng
- College of Textiles and Clothing, Xinjiang University, Urumqi 830046, China
- Beijing Institute of Radiation Medicine, Beijing 100850, China
| | - Yongyue Ning
- Beijing Institute of Radiation Medicine, Beijing 100850, China
- Key Laboratory of Nanobiosensing and Nanobioanalysis, Universities of Jilin Province, Northeast Normal University, Changchun 130024, China
| | - Zhongdong Wu
- Beijing Institute of Radiation Medicine, Beijing 100850, China
| | - Zihan Li
- Beijing Institute of Radiation Medicine, Beijing 100850, China
- Key Laboratory of Nanobiosensing and Nanobioanalysis, Universities of Jilin Province, Northeast Normal University, Changchun 130024, China
| | - Cuixing Xu
- Beijing Institute of Radiation Medicine, Beijing 100850, China
| | - Gangyong Li
- Beijing Institute of Radiation Medicine, Beijing 100850, China
- Key Laboratory of Hunan Province for Advanced Carbon-Based Functional Materials, School of Chemistry and Chemical Engineering, Hunan Institute of Science and Technology, Yueyang 414006, China
| | - Zongqian Hu
- Beijing Institute of Radiation Medicine, Beijing 100850, China
| |
Collapse
|
5
|
Multifunctional glycoprotein coatings improve the surface properties of highly oxygen permeable contact lenses. BIOMATERIALS ADVANCES 2023; 145:213233. [PMID: 36521413 DOI: 10.1016/j.bioadv.2022.213233] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/08/2022] [Revised: 11/03/2022] [Accepted: 11/30/2022] [Indexed: 12/13/2022]
Abstract
To achieve and maintain good operability of medical devices while reducing putative side effects for the patient, a promising strategy is to tailor the surface properties of such devices as they critically dictate the tissue compatibility and the biofouling behavior. Indeed, those properties can be strongly improved by generating mucin coatings on such medical devices. However, using coatings on optical systems, e.g., contact lenses, comes with various challenges: here, the geometrical and optical characteristics of the lens may not be compromised by either the coating process or the coating itself. In this study, we show how mucin macromolecules can be attached onto the surfaces of rigid, gas permeable contact lenses while maintaining all critical lens parameters. We demonstrate that the generated coatings improve the surface wettability (contact angles are reduced from 105° to 40° and liquid film break-up times are increased from <1 s to 31 s) and prevent tribological damage to corneal tissue. Additionally, such coatings are highly transparent (transmission values above 98 % compared to an uncoated sample are reached) and efficiently reduce lipid deposition to the lens surface by 90 % but fully maintain the geometrical and mechanical properties of the lenses. Thus, such mucin coatings could also be highly beneficial for other optical systems that are used in direct contact with tissues or body fluids.
Collapse
|
6
|
Biomedical metallic materials based on nanocrystalline and nanoporous microstructures: Properties and applications. Nanomedicine (Lond) 2023. [DOI: 10.1016/b978-0-12-818627-5.00030-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/19/2023] Open
|
7
|
Zhang W, Zhang J, Fan S, Zhang L, Liu C, Liu J. Oxygen reduction catalyzed by bilirubin oxidase and applications in biosensors and biofuel cells. Microchem J 2022. [DOI: 10.1016/j.microc.2022.108052] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
8
|
Ghorbanzadeh S, Naghib SM, Sadr A, Molaabasi F, Zhang W. A customizable cost-effective design for printed circuit board-based nanolayered gold screen-printed electrode: From fabrication to bioapplications. Front Bioeng Biotechnol 2022; 10:1036224. [DOI: 10.3389/fbioe.2022.1036224] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2022] [Accepted: 10/10/2022] [Indexed: 11/06/2022] Open
Abstract
Screen-printed electrodes (SPEs) are promising candidates for fabricating biosensing platforms in the laboratory and industry due to the various advantages they involve. The primary method for fabricating SPEs is 2D printing. However, commercial SPEs have some limitations due to the specific ports and connections they require, inflexible design, high prices, and decreased efficiency after a short time. This article introduces high performance, feasible, and cost-effective gold SPEs based on the combination of printed circuit board substrate (PCBs) and sputtering methods for electrochemical biosensing platforms. First, we discuss a general gold SPE development procedure that helps researchers to develop specific designs. The final developed version of SPEs was characterized in the second step, showing positive performance in electrochemical parameters because of the optimization of design and fabrication steps. In the study’s final phase, SPEs were used to fabricate a simple platform for breast cancer cell detection as a proof of concept without using any linker or labeling step. The designed immunosensor is very simple and cost-effective, showing a linear calibration curve in the range of 10 − 2× 102 cells mL−1 (R2 = 0.985, S/N = 3). This research can be used as a reference for future studies in SPEs-based biosensors because of the flexibility of its design and the accessibility of the manufacturing equipment required.
Collapse
|
9
|
Sondhi P, Neupane D, Bhattarai JK, Demchenko AV, Stine KJ. Facile fabrication of hierarchically nanostructured gold electrode for bio-electrochemical applications. J Electroanal Chem (Lausanne) 2022; 924:116865. [PMID: 36405880 PMCID: PMC9673609 DOI: 10.1016/j.jelechem.2022.116865] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/31/2022]
Abstract
Nanoporous gold (NPG) is one of the most extensively investigated nanomaterials owing to its tunable pore size, ease of surface modification, and range of applications from catalysis, actuation, and molecular release to the development of electrochemical sensors. In an effort to improve the usefulness of NPG, a simple and robust method for the fabrication of hierarchical and bimodal nanoporous gold electrodes (hb-NPG) containing both macro-and mesopores is reported using electrochemical alloying and dealloying processes to engineer a bicontinuous solid/void morphology. Scanning electron microscopy (color SEM) images depict the hierarchical pore structure created after the multistep synthesis with an ensemble of tiny pores below 100 nm in size located in ligaments spanning larger pores of several hundred nanometers. Smaller-sized pores are exploited for surface modification, and the network of larger pores aids in molecular transport. Cyclic voltammetry (CV) was used to compare the electrochemically active surface area of the hierarchical bimodal structure with that of the regular unimodal NPG with an emphasis on the critical role of both dealloying and annealing in creating the desired structure. The adsorption of different proteins was followed using UV-vis absorbance measurements of solution depletion revealing the high loading capacity of hb-NPG. The surface coverage of lipoic acid on the hb-NPG was analyzed using thermogravimetric analysis (TGA) and reductive desorption. The roughness factor determinations suggest that the fabricated hb-NPG electrode has tremendous potential for biosensor development by changing the scaling relations between volume and surface area which may lead to improved analytical performance. We have chosen to take advantage of the surface architectures of hb-NPG due to the presence of a large specific surface area for functionalization and rapid transport pathways for faster response. It is shown that the hb-NPG electrode has a higher sensitivity for the amperometric detection of glucose than does an NPG electrode of the same geometric surface area.
Collapse
Affiliation(s)
- Palak Sondhi
- Department of Chemistry and Biochemistry, University of Missouri–St. Louis, Saint Louis, MO 63121, USA
| | - Dharmendra Neupane
- Department of Chemistry and Biochemistry, University of Missouri–St. Louis, Saint Louis, MO 63121, USA
| | - Jay K. Bhattarai
- Department of Chemistry and Biochemistry, University of Missouri–St. Louis, Saint Louis, MO 63121, USA
| | | | - Keith J. Stine
- Department of Chemistry and Biochemistry, University of Missouri–St. Louis, Saint Louis, MO 63121, USA
| |
Collapse
|
10
|
Kang D, Lee JI, Maeng B, Lee S, Kwon Y, Kang MS, Park J, Kim J. Safe, Durable, and Sustainable Self-Powered Smart Contact Lenses. ACS NANO 2022; 16:15827-15836. [PMID: 36069332 DOI: 10.1021/acsnano.2c05452] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Smart contact lenses have the potential to serve as noninvasive healthcare devices or virtual displays. However, their implementation is limited by the lack of suitable power sources for microelectronic devices. This Article demonstrates smart contact lenses with fully embedded glucose fuel cells that are safe, flexible, and durable against deformations. These fuel cells produced stable power throughout the day or during intermittent use after storage for weeks. When the lenses were exposed to 0.05 mM glucose solution, a steady-state maximum power density of 4.4 μW/cm2 was achieved by optimizing the chemistry and porous structure of the fuel cell components. Additionally, even after bending the lenses in half 100 times, the fuel cell performance was maintained without any mechanical failure. Lastly, when the fuel cells were connected to electroresponsive hydrogel capacitors, we could clearly distinguish between the tear glucose levels under normal and diabetic conditions through the naked eye.
Collapse
Affiliation(s)
- Dongwon Kang
- Department of Chemical and Biomolecular Engineering, Sogang University, Seoul 04107, Republic of Korea
| | - Jong Ik Lee
- Department of Chemical and Biomolecular Engineering, Sogang University, Seoul 04107, Republic of Korea
| | - Bohee Maeng
- Department of Mechanical Engineering, Sogang University, Seoul 04107, Republic of Korea
| | - Seyeon Lee
- Department of Mechanical Engineering, Sogang University, Seoul 04107, Republic of Korea
| | - Yongseok Kwon
- School of Pharmacy, Sungkyunkwan University, Suwon 16419, Republic of Korea
| | - Moon Sung Kang
- Department of Chemical and Biomolecular Engineering, Sogang University, Seoul 04107, Republic of Korea
- Institute of Emergent Materials, Sogang University, Seoul 04107, Republic of Korea
| | - Jungyul Park
- Department of Mechanical Engineering, Sogang University, Seoul 04107, Republic of Korea
| | - Jungwook Kim
- Department of Chemical and Biomolecular Engineering, Sogang University, Seoul 04107, Republic of Korea
| |
Collapse
|
11
|
Arshi S, Xiao X, Belochapkine S, Magner E. Electrochemical Immobilisation of Glucose Oxidase for the Controlled Production of H 2O 2 in a Biocatalytic Flow Reactor. ChemElectroChem 2022; 9:e202200319. [PMID: 36246851 PMCID: PMC9545823 DOI: 10.1002/celc.202200319] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2022] [Revised: 06/24/2022] [Indexed: 11/09/2022]
Abstract
Electrochemical methods can be used to selectively modify the surfaces of electrodes, enabling the immobilisation of enzymes on defined areas on the surfaces of electrodes. Such selective immobilisation methods can be used to pattern catalysts on surfaces in a controlled manner. Using this approach, the selective patterning of the enzyme glucose oxidase on the electrodes was used to develop a flow reactor for the controlled delivery of the oxidant H2O2. GOx was immobilised on a glassy carbon electrode using polypyrrole, silica films, and diazonium linkers. The rate of production of H2O2 and the stability of the response was dependent on the immobilisation method. GOx encapsulated in polypyrrole was selected as the optimal method of immobilisation, with a rate of production of 91±11 μM h-1 for 4 hours of continuous operation. The enzyme was subsequently immobilised on carbon rod electrodes (surface area of 5.76 cm2) using a polypyrrole/Nafion® film and incorporated into a flow reactor. The rate of production of H2O2 was 602±57 μM h-1, with 100 % retention of activity after 7 h of continuous operation, demonstrating that such a system can be used to prepare H2O2 at continuous and stable rate for use in downstream oxidation reactions.
Collapse
Affiliation(s)
- Simin Arshi
- Department of Chemical SciencesBernal InstituteUniversity of LimerickV94 T9PXLimerickIreland
| | - Xinxin Xiao
- Department of ChemistryTechnical University of DenmarkKongens Lyngby2800Denmark
| | - Serguei Belochapkine
- Department of Chemical SciencesBernal InstituteUniversity of LimerickV94 T9PXLimerickIreland
| | - Edmond Magner
- Department of Chemical SciencesBernal InstituteUniversity of LimerickV94 T9PXLimerickIreland
| |
Collapse
|
12
|
Engineering bio-interfaces for the direct electron transfer of Myriococcum thermophilum cellobiose dehydrogenase: Towards a mediator-less biosupercapacitor/biofuel cell hybrid. Biosens Bioelectron 2022; 210:114337. [PMID: 35537312 DOI: 10.1016/j.bios.2022.114337] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2022] [Revised: 04/28/2022] [Accepted: 04/30/2022] [Indexed: 12/24/2022]
Abstract
Direct electron transfer (DET) of enzymes on electrode surfaces is highly desirable both for fundamental mechanistic studies and to achieve membrane- and mediator-less bioenergy harvesting. In this report, we describe the preparation and comprehensive structural and electrochemical characterization of a three-dimensional (3D) graphene-based carbon electrode, onto which the two-domain redox enzyme Myriococcum thermophilum cellobiose dehydrogenase (MtCDH) is immobilized. The electrode is prepared by an entirely novel method, which combines in a single step electrochemical reduction of graphene oxide (GO) and simultaneous electrodeposition of positively charged polyethylenimine (PEI), resulting in a well dispersed MtCDH surface. The resulting MtCDH bio-interface was characterized structurally in detail, optimized, and found to exhibit a DET maximum current density of 7.7 ± 0.9 μA cm-2 and a half-lifetime of 48 h for glucose oxidation, attributed to favorable MtCDH surface orientation. A dual, entirely DET-based enzymatic biofuel cell (EBFC) was constructed with a MtCDH bioanode and a Myrothecium verrucaria bilirubin oxidase (MvBOD) biocathode. The EBFC delivers a maximum power density (Pmax) of 7.6 ± 1.3 μW cm-2, an open-circuit voltage (OCV) of 0.60 V, and an operational lifetime over seven days, which exceeds most reported CDH based DET-type EBFCs. A biosupercapacitor/EBFC hybrid was also constructed and found to register maximum power densities 62 and 43 times higher than single glucose/air and lactose/air EBFCs, respectively. This hybrid also shows excellent operational stability with self-charging/discharging over at least 500 cycles.
Collapse
|
13
|
Cai Y, Wang M, Xiao X, Liang B, Fan S, Zheng Z, Cosnier S, Liu A. A membraneless starch/O 2 biofuel cell based on bacterial surface regulable displayed sequential enzymes of glucoamylase and glucose dehydrogenase. Biosens Bioelectron 2022; 207:114197. [PMID: 35358946 DOI: 10.1016/j.bios.2022.114197] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2022] [Revised: 03/14/2022] [Accepted: 03/16/2022] [Indexed: 11/02/2022]
Abstract
Enzymatic biofuel cells (EBFCs) provide a new strategy to enable direct biomass-to-electricity conversion, posing considerable demand on sequential enzymes. However, artificial blend of multi-enzyme systems often suffer biocatalytic inefficiency due to the rambling mixture of catalytic units. In an attempt to construct a high-performance starch/O2 EBFC, herein we prepared a starch-oxidizing bioanode based on displaying a sequential enzyme system of glucoamylase (GA) and glucose dehydrogenase (GDH) on E.coli cell surfaces in a precise way using cohesin-dockerin interactions. The enzyme stoichiometry was optimized, with GA&GDH (3:1)-E.coli exhibiting the highest catalytic reaction rate. The bioanode employed polymerized methylene blue (polyMB) to collect electrons from the oxidation of NADH into NAD+, which jointly oxidized starch together with co-displayed GA and GDH. The bioanode was oxygen-insensitive, which can be combined with a laccase based biocathode, resulting in a membranless starch/O2 EBFC in a non-compartmentalized configuration. The optimal EBFC exhibited an open-circuit voltage (OCV) of 0.74 V, a maximum power density of 30.1 ± 2.8 μW cm-2, and good operational stability.
Collapse
Affiliation(s)
- Yuanyuan Cai
- Institute for Biosensing, and College of Life Sciences, Qingdao University, Qingdao, 266071, China
| | - Mingyang Wang
- Institute for Biosensing, and College of Life Sciences, Qingdao University, Qingdao, 266071, China
| | - Xinxin Xiao
- Institute for Biosensing, and College of Life Sciences, Qingdao University, Qingdao, 266071, China; Department of Chemistry, Technical University of Denmark, 2800, Kongens Lyngby, Denmark
| | - Bo Liang
- Qingdao Institute of Bioenergy & Bioprocess Technology, Chinese Academy of Sciences, 189 Songling Road, Qingdao, 266101, China
| | - Shuqin Fan
- Qingdao Institute of Bioenergy & Bioprocess Technology, Chinese Academy of Sciences, 189 Songling Road, Qingdao, 266101, China
| | - Zongmei Zheng
- Institute for Biosensing, and College of Life Sciences, Qingdao University, Qingdao, 266071, China
| | - Serge Cosnier
- University Grenoble Alpes DCM UMR 5250, F-38000, Grenoble, France; Département de Chimie Moléculaire, UMR CNRS, DCM UMR 5250, F-38000, Grenoble, France
| | - Aihua Liu
- Institute for Biosensing, and College of Life Sciences, Qingdao University, Qingdao, 266071, China.
| |
Collapse
|
14
|
Pinyou P, Blay V, Kamkaew A, Chansaenpak K, Kampaengsri S, Jakmunee J, Tongnark M, Reesunthia I, Khonru T. Wiring Xanthine Oxidase using an Osmium‐Complex‐modified Polymer for Application in Biosensing. ChemElectroChem 2022. [DOI: 10.1002/celc.202101597] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Affiliation(s)
- Piyanut Pinyou
- Suranaree University of Technology Institute of Science Institute of Science Suranaree University of Technology 30000 Nakhon Ratschasima THAILAND
| | - Vincent Blay
- University of California Santa Cruz Microbiology and Environmental Toxicology UNITED STATES
| | - Anyanee Kamkaew
- Suranaree University of Technology Institute of Science THAILAND
| | | | | | | | | | | | - Tunjiranon Khonru
- Suranaree University of Technology SCiPUS, Surawiwat School THAILAND
| |
Collapse
|
15
|
Mirzajani H, Mirlou F, Istif E, Singh R, Beker L. Powering smart contact lenses for continuous health monitoring: Recent advancements and future challenges. Biosens Bioelectron 2022; 197:113761. [PMID: 34800926 DOI: 10.1016/j.bios.2021.113761] [Citation(s) in RCA: 24] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2021] [Revised: 10/15/2021] [Accepted: 10/29/2021] [Indexed: 12/16/2022]
Abstract
As the tear is noninvasively and continuously available, it has been turned into a convenient biological interface as a wearable medical device for out-of-hospital and self-monitoring applications. Recent progress in integrated circuits (ICs) and biosensors coupled with wireless data communication techniques have led to the implementation of smart contact lenses that can continuously sample tear fluid, analyze physiological conditions, and wirelessly transmit data to an electronic device such as smartphone, which can send data to relevant healthcare units. Continuous analyte monitoring is one of the significant characteristics of wearable biosensors. However, despite several advantages over other on-skin wearable medical devices, batteries cannot be incorporated on smart contact lenses for continuous electrical power supply due to the limited area. Herein, we review the progress of power delivery techniques of smart contact lenses for the first time. Different approaches, including wireless power transmission (WPT), biofuel cells, supercapacitors, flexible batteries, wired connections, and hybrid methods, are thoroughly discussed to understand the principles of self-sustainable contact lens biosensors comprehensively. Additionally, recent progress in contact lens biosensors is reviewed in detail, thereby providing the prospects for further developments of smart contact lenses as a common biosensing platform for various disease monitoring and diagnostic applications.
Collapse
Affiliation(s)
- Hadi Mirzajani
- Department of Mechanical Engineering, Koç University, Rumelifeneri Yolu, Sarıyer, Istanbul, 34450, Turkey
| | - Fariborz Mirlou
- Department of Electrical and Electronics Engineering, Koç University, Rumelifeneri Yolu, Sarıyer, Istanbul, 34450, Turkey
| | - Emin Istif
- Department of Mechanical Engineering, Koç University, Rumelifeneri Yolu, Sarıyer, Istanbul, 34450, Turkey
| | - Rahul Singh
- Department of Mechanical Engineering, Koç University, Rumelifeneri Yolu, Sarıyer, Istanbul, 34450, Turkey
| | - Levent Beker
- Department of Mechanical Engineering, Koç University, Rumelifeneri Yolu, Sarıyer, Istanbul, 34450, Turkey; Koç University Research Center for Translational Research (KUTTAM), Rumelifeneri Yolu, Sarıyer, Istanbul, 34450, Turkey.
| |
Collapse
|
16
|
Affiliation(s)
- Huixin Liu
- Shanghai Environmental Protection Key Laboratory for Environmental Standard and Risk Management of Chemical Pollutants School of Resources & Environmental Engineering East China University of Science & Technology Shanghai 200237 PR China
- State Environmental Protection Key Lab of Environmental Risk Assessment and Control on Chemical Processes School of Resources & Environmental Engineering East China University of Science & Technology Shanghai 200237 PR China
| | - Xiaomei Yan
- Department of Chemistry Technical University of Denmark Kongens Lyngby 2800 Denmark
| | - Zhen Gu
- Department of Automation School of Information Science and Engineering East China University of Science & Technology Shanghai 200237 PR China
| | - Guangli Xiu
- Shanghai Environmental Protection Key Laboratory for Environmental Standard and Risk Management of Chemical Pollutants School of Resources & Environmental Engineering East China University of Science & Technology Shanghai 200237 PR China
- State Environmental Protection Key Lab of Environmental Risk Assessment and Control on Chemical Processes School of Resources & Environmental Engineering East China University of Science & Technology Shanghai 200237 PR China
| | - Xinxin Xiao
- Department of Chemistry Technical University of Denmark Kongens Lyngby 2800 Denmark
| |
Collapse
|
17
|
Vallem V, Sargolzaeiaval Y, Ozturk M, Lai YC, Dickey MD. Energy Harvesting and Storage with Soft and Stretchable Materials. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2021; 33:e2004832. [PMID: 33502808 DOI: 10.1002/adma.202004832] [Citation(s) in RCA: 40] [Impact Index Per Article: 13.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/15/2020] [Revised: 09/04/2020] [Indexed: 06/12/2023]
Abstract
This review highlights various modes of converting ambient sources of energy into electricity using soft and stretchable materials. These mechanical properties are useful for emerging classes of stretchable electronics, e-skins, bio-integrated wearables, and soft robotics. The ability to harness energy from the environment allows these types of devices to be tetherless, thereby leading to a greater range of motion (in the case of robotics), better compliance (in the case of wearables and e-skins), and increased application space (in the case of electronics). A variety of energy sources are available including mechanical (vibrations, human motion, wind/fluid motion), electromagnetic (radio frequency (RF), solar), and thermodynamic (chemical or thermal energy). This review briefly summarizes harvesting mechanisms and focuses on the materials' strategies to render such devices into soft or stretchable embodiments.
Collapse
Affiliation(s)
- Veenasri Vallem
- Department of Chemical and Biomolecular Engineering, North Carolina State University, Raleigh, NC, 27695, USA
| | - Yasaman Sargolzaeiaval
- Department of Electrical and Computer Engineering, North Carolina State University, Raleigh, NC, 27695, USA
| | - Mehmet Ozturk
- Department of Electrical and Computer Engineering, North Carolina State University, Raleigh, NC, 27695, USA
| | - Ying-Chih Lai
- Department of Materials Science and Engineering, National Chung Hsing University, Taichung, 402, Taiwan
- Innovation and Development Center of Sustainable Agriculture, Research Center for Sustainable Energy and Nanotechnology, National Chung Hsing University, Taichung, 402, Taiwan
| | - Michael D Dickey
- Department of Chemical and Biomolecular Engineering, North Carolina State University, Raleigh, NC, 27695, USA
| |
Collapse
|
18
|
Kim SH. Nanoporous Gold for Energy Applications. CHEM REC 2021; 21:1199-1215. [PMID: 33734584 DOI: 10.1002/tcr.202100015] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2021] [Revised: 03/01/2021] [Accepted: 03/01/2021] [Indexed: 11/12/2022]
Abstract
Research activities using nanoporous gold (NPG) were reviewed in the field of energy applications in three categories: fuel cells, supercapacitors, and batteries. First, applications to fuel cells are reviewed with the subsections of proof-of-concept studies, studies on fuel oxidations at anode, and studies on oxygen reduction reactions at cathode. Second, applications to supercapacitors are reviewed from research activities on active materials/NPG composites to demonstrations of all-solid-state flexible supercapacitors using NPG electrodes. Third, research activities using NPG for battery applications are reviewed, mainly about fundamental studies on Li-air and Na-air batteries and some model studies on improving Li ion battery anodes. Although NPG based studies are the main subject of this review, some of meaningful studies using nanoporous metals are also discussed where relevant. Finally, summary and future outlook are given based on the survey on the research activities.
Collapse
Affiliation(s)
- Sang Hoon Kim
- Materials Architecturing Research Center, Korea Institute of Science and Technology, Seoul, 02792, Korea, Division of Nano & Information Technology at KIST School, University of Science and Technology, Daejeon, 34113, Korea
| |
Collapse
|
19
|
Polymer coating for improved redox-polymer-mediated enzyme electrodes: A mini-review. Electrochem commun 2021. [DOI: 10.1016/j.elecom.2021.106931] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022] Open
|
20
|
Xiao S, Wang S, Wang X, Xu P. Nanoporous gold: A review and potentials in biotechnological and biomedical applications. NANO SELECT 2021. [DOI: 10.1002/nano.202000291] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2023] Open
Affiliation(s)
- Sa Xiao
- State Key Laboratory of Microbial Technology Shandong University Qingdao PR China
| | - Shuangjue Wang
- State Key Laboratory of Microbial Technology Shandong University Qingdao PR China
| | - Xia Wang
- State Key Laboratory of Microbial Technology Shandong University Qingdao PR China
| | - Ping Xu
- State Key Laboratory of Microbial Metabolism and School of Life Sciences and Biotechnology Shanghai Jiao Tong University Shanghai PR China
| |
Collapse
|
21
|
Tappan BC, Steiner Iii SA, Dervishi E, Mueller AH, Scott BL, Sheehan C, Luther EP, Lichthardt JP, Dirmyer MR. Monolithic Nanoporous Gold Foams with Catalytic Activity for Chemical Vapor Deposition Growth of Carbon Nanostructures. ACS APPLIED MATERIALS & INTERFACES 2021; 13:1204-1213. [PMID: 33356086 DOI: 10.1021/acsami.0c17624] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
While bulk gold is generally considered to be a catalytically inactive material, nanostructured forms of gold can in fact be highly catalytically active. However, few methods exist for preparing high-purity macroscopic forms of catalytically active gold. In this work, we describe the synthesis of catalytically active macroscopic nanoporous gold foams via combustion synthesis of gold bis(tetrazolato)amine complexes. The resulting metallically pure porous gold nanoarchitectures exhibit bulk densities of <0.1 g/cm3 and Brunauer-Emmett-Teller (BET) surface areas as high as 10.9 m2/g, making them among the lowest-density and highest-surface-area monolithic forms of gold produced to date. Thanks to the presence of a highly nanostructured gold surface, such gold nanofoams have also been found to be highly catalytically active toward thermal chemical vapor deposition (CVD) growth of carbon nanotubes, providing a novel method for direct synthesis of carbon nanostructures on macroscopic gold substrates. In contrast, analogous copper nanofoams were found to be catalytically inactive toward the growth of graphitic nanostructures under the same synthesis conditions, highlighting the unusually high catalytic propensity of this form factor of gold. The combustion synthesis process described herein represents a never-wet approach for directly synthesizing macroscopic catalytically active gold. Unlike sol-gel and dealloying approaches, combustion synthesis eliminates the time-consuming diffusion-mediated steps associated with previous methods and offers multiple degrees of freedom for tuning morphology, electrical conductivity, and mechanical properties.
Collapse
Affiliation(s)
- Bryce C Tappan
- Los Alamos National Laboratory MS C920, Los Alamos, New Mexico 87545, United States
| | - Stephen A Steiner Iii
- Los Alamos National Laboratory MS C920, Los Alamos, New Mexico 87545, United States
- Aerogel Technologies, LLC, 1 Westinghouse Plaza, Boston, Massachusetts 02136, United States
| | - Enkeleda Dervishi
- Los Alamos National Laboratory MS G755, Los Alamos, New Mexico 87545, United States
| | - Alexander H Mueller
- Los Alamos National Laboratory MS C920, Los Alamos, New Mexico 87545, United States
| | - Brian L Scott
- Los Alamos National Laboratory MS J514, Los Alamos, New Mexico 87545, United States
| | - Chris Sheehan
- Los Alamos National Laboratory MS K771, Los Alamos, New Mexico 87545, United States
| | - Erik P Luther
- Los Alamos National Laboratory MS G774, Los Alamos, New Mexico 87545, United States
| | - Joseph P Lichthardt
- Los Alamos National Laboratory MS C920, Los Alamos, New Mexico 87545, United States
| | - Matthew R Dirmyer
- Los Alamos National Laboratory MS J964, Los Alamos, New Mexico 87545, United States
| |
Collapse
|
22
|
Direct Electrochemical Enzyme Electron Transfer on Electrodes Modified by Self-Assembled Molecular Monolayers. Catalysts 2020. [DOI: 10.3390/catal10121458] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022] Open
Abstract
Self-assembled molecular monolayers (SAMs) have long been recognized as crucial “bridges” between redox enzymes and solid electrode surfaces, on which the enzymes undergo direct electron transfer (DET)—for example, in enzymatic biofuel cells (EBFCs) and biosensors. SAMs possess a wide range of terminal groups that enable productive enzyme adsorption and fine-tuning in favorable orientations on the electrode. The tunneling distance and SAM chain length, and the contacting terminal SAM groups, are the most significant controlling factors in DET-type bioelectrocatalysis. In particular, SAM-modified nanostructured electrode materials have recently been extensively explored to improve the catalytic activity and stability of redox proteins immobilized on electrochemical surfaces. In this report, we present an overview of recent investigations of electrochemical enzyme DET processes on SAMs with a focus on single-crystal and nanoporous gold electrodes. Specifically, we consider the preparation and characterization methods of SAMs, as well as SAM applications in promoting interfacial electrochemical electron transfer of redox proteins and enzymes. The strategic selection of SAMs to accord with the properties of the core redox protein/enzymes is also highlighted.
Collapse
|
23
|
Jarboui A, Holade Y, Mericq J, Charmette C, Thami T, Biermans P, Tingry S, Bouyer D. Electroanalytical Assessment of the Oxygen Permeability at the Gas‐Solid‐Liquid Interface in Polymer‐based Materials for Lens Applications. ChemElectroChem 2020. [DOI: 10.1002/celc.202001160] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Affiliation(s)
- Ahmed Jarboui
- Institut Européen des Membranes IEM UMR 5635, Univ Montpellier, ENSCM, CNRS, Montpellier, France
- Ophtimalia 5 esplanade Anton Philips Campus EffiScience 14460 Colombelles France
| | - Yaovi Holade
- Institut Européen des Membranes IEM UMR 5635, Univ Montpellier, ENSCM, CNRS, Montpellier, France
| | - Jean‐Pierre Mericq
- Institut Européen des Membranes IEM UMR 5635, Univ Montpellier, ENSCM, CNRS, Montpellier, France
| | - Christophe Charmette
- Institut Européen des Membranes IEM UMR 5635, Univ Montpellier, ENSCM, CNRS, Montpellier, France
| | - Thierry Thami
- Institut Européen des Membranes IEM UMR 5635, Univ Montpellier, ENSCM, CNRS, Montpellier, France
| | - Peter Biermans
- Ophtimalia 5 esplanade Anton Philips Campus EffiScience 14460 Colombelles France
| | - Sophie Tingry
- Institut Européen des Membranes IEM UMR 5635, Univ Montpellier, ENSCM, CNRS, Montpellier, France
| | - Denis Bouyer
- Institut Européen des Membranes IEM UMR 5635, Univ Montpellier, ENSCM, CNRS, Montpellier, France
| |
Collapse
|
24
|
Abstract
Bioelectrocatalysis has become one of the most important research fields in electrochemistry and provided a firm base for the application of important technology in various bioelectrochemical devices, such as biosensors, biofuel cells, and biosupercapacitors. The understanding and technology of bioelectrocatalysis have greatly improved with the introduction of nanostructured electrode materials and protein-engineering methods over the last few decades. Recently, the electroenzymatic production of renewable energy resources and useful organic compounds (bioelectrosynthesis) has attracted worldwide attention. In this review, we summarize recent progress in the applications of enzymatic bioelectrocatalysis.
Collapse
|
25
|
Tang J, Yan X, Huang W, Engelbrekt C, Duus JØ, Ulstrup J, Xiao X, Zhang J. Bilirubin oxidase oriented on novel type three-dimensional biocathodes with reduced graphene aggregation for biocathode. Biosens Bioelectron 2020; 167:112500. [PMID: 32829175 DOI: 10.1016/j.bios.2020.112500] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2020] [Revised: 08/04/2020] [Accepted: 08/04/2020] [Indexed: 11/29/2022]
Abstract
Aggregation of reduced graphene oxide (RGO) due to π-π stacking is a recurrent problem in graphene-based electrochemistry, decreasing the effective working area and therefore the performance of the RGO electrodes. Dispersing RGO on three-dimensional (3D) carbon paper electrodes is one strategy towards overcoming this challenge, with partial relief aggregation. In this report, we describe the grafting of negatively charged 4-aminobenzoic acid (4-ABA) onto a graphene functionalized carbon paper electrode surface. 4-ABA functionalization induces separation of the RGO layers, at the same time leading to favorable orientation of the blue multi-copper enzyme Myrothecium verrucaria bilirubin oxidase (MvBOD) for direct electron transfer (DET) in the dioxygen reduction reaction (ORR) at neutral pH. Simultaneous electroreduction of graphene oxide to RGO and covalent attachment of 4-ABA are achieved by applying alternating cathodic and anodic electrochemical potential pulses, leading to a high catalytic current density (Δjcat:193 ± 4 μA cm-2) under static conditions. Electrochemically grafted 4-ABA not only leads to a favorable orientation of BOD as validated by fitting a kinetic model to the electrocatalytic data, but also acts to alleviate RGO aggregation as disclosed by scanning electron microscopy, most likely due to the electrostatic repulsion between 4-ABA-grafted graphene layers. With a half-lifetime of 55 h, the bioelectrode also shows the highest operational stability for DET-type MvBOD-based bioelectrodes reported to date. The bioelectrode was finally shown to work well as a biocathode of a membrane-less glucose/O2 enzymatic biofuel cell with a maximum power density of 22 μW cm-2 and an open circuit voltage of 0.51 V.
Collapse
Affiliation(s)
- Jing Tang
- Department of Chemistry, Technical University of Denmark, Kongens Lyngby, 2800, Denmark
| | - Xiaomei Yan
- Department of Chemistry, Technical University of Denmark, Kongens Lyngby, 2800, Denmark
| | - Wei Huang
- Department of Chemistry, Technical University of Denmark, Kongens Lyngby, 2800, Denmark
| | - Christian Engelbrekt
- Department of Chemistry, Technical University of Denmark, Kongens Lyngby, 2800, Denmark
| | - Jens Øllgaard Duus
- Department of Chemistry, Technical University of Denmark, Kongens Lyngby, 2800, Denmark
| | - Jens Ulstrup
- Department of Chemistry, Technical University of Denmark, Kongens Lyngby, 2800, Denmark; Kazan National Research Technological University, K. Marx Str., 68, 420015, Kazan, Republic of Tatarstan, Russia
| | - Xinxin Xiao
- Department of Chemistry, Technical University of Denmark, Kongens Lyngby, 2800, Denmark.
| | - Jingdong Zhang
- Department of Chemistry, Technical University of Denmark, Kongens Lyngby, 2800, Denmark.
| |
Collapse
|
26
|
Jin X, Bandodkar AJ, Fratus M, Asadpour R, Rogers JA, Alam MA. Modeling, design guidelines, and detection limits of self-powered enzymatic biofuel cell-based sensors. Biosens Bioelectron 2020; 168:112493. [DOI: 10.1016/j.bios.2020.112493] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2020] [Revised: 07/30/2020] [Accepted: 07/31/2020] [Indexed: 12/29/2022]
|
27
|
Buaki-Sogó M, García-Carmona L, Gil-Agustí M, Zubizarreta L, García-Pellicer M, Quijano-López A. Enzymatic Glucose-Based Bio-batteries: Bioenergy to Fuel Next-Generation Devices. Top Curr Chem (Cham) 2020; 378:49. [PMID: 33125588 DOI: 10.1007/s41061-020-00312-8] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2018] [Accepted: 10/05/2020] [Indexed: 11/26/2022]
Abstract
This article consists of a review of the main concepts and paradigms established in the field of biological fuel cells or biofuel cells. The aim is to provide an overview of the current panorama, basic concepts, and methodologies used in the field of enzymatic biofuel cells, as well as the applications of these bio-systems in flexible electronics and implantable or portable devices. Finally, the challenges needing to be addressed in the development of biofuel cells capable of supplying power to small size devices with applications in areas related to health and well-being or next-generation portable devices are analyzed. The aim of this study is to contribute to biofuel cell technology development; this is a multidisciplinary topic about which review articles related to different scientific areas, from Materials Science to technology applications, can be found. With this article, the authors intend to reach a wide readership in order to spread biofuel cell technology for different scientific profiles and boost new contributions and developments to overcome future challenges.
Collapse
Affiliation(s)
- Mireia Buaki-Sogó
- Instituto Tecnológico de la Energía (ITE), Avenida Juan de la Cierva, 24, 46980, Paterna, Valencia, Spain.
| | - Laura García-Carmona
- Instituto Tecnológico de la Energía (ITE), Avenida Juan de la Cierva, 24, 46980, Paterna, Valencia, Spain
| | - Mayte Gil-Agustí
- Instituto Tecnológico de la Energía (ITE), Avenida Juan de la Cierva, 24, 46980, Paterna, Valencia, Spain
| | - Leire Zubizarreta
- Instituto Tecnológico de la Energía (ITE), Avenida Juan de la Cierva, 24, 46980, Paterna, Valencia, Spain
| | - Marta García-Pellicer
- Instituto Tecnológico de la Energía (ITE), Avenida Juan de la Cierva, 24, 46980, Paterna, Valencia, Spain
| | - Alfredo Quijano-López
- ITE Universitat Politécnica de València, Camino de Vera s/n edificio 6C, 46022, Valencia, Spain
| |
Collapse
|
28
|
Abstract
Biocatalysts provide a number of advantages such as high selectivity, the ability to operate under mild reaction conditions and availability from renewable resources that are of interest in the development of bioreactors for applications in the pharmaceutical and other sectors. The use of oxidoreductases in biocatalytic reactors is primarily focused on the use of NAD(P)-dependent enzymes, with the recycling of the cofactor occurring via an additional enzymatic system. The use of electrochemically based systems has been limited. This review focuses on the development of electrochemically based biocatalytic reactors. The mechanisms of mediated and direct electron transfer together with methods of immobilising enzymes are briefly reviewed. The use of electrochemically based batch and flow reactors is reviewed in detail with a focus on recent developments in the use of high surface area electrodes, enzyme engineering and enzyme cascades. A future perspective on electrochemically based bioreactors is presented.
Collapse
|
29
|
Xiao X, McGourty KD, Magner E. Enzymatic Biofuel Cells for Self-Powered, Controlled Drug Release. J Am Chem Soc 2020; 142:11602-11609. [PMID: 32510936 DOI: 10.1021/jacs.0c05749] [Citation(s) in RCA: 36] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
Self-powered drug-delivery systems based on conductive polymers (CPs) that eliminate the need for external power sources are of significant interest for use in clinical applications. Osmium redox polymer-mediated glucose/O2 enzymatic biofuel cells (EBFCs) were prepared with an additional CP-drug layer on the cathode. On discharging the EBFCs in the presence of glucose and dioxygen, model drug compounds incorporated in the CP layer were rapidly released with negligible amounts released when the EBFCs were held at open circuit. Controlled and ex situ release of three model compounds, ibuprofen (IBU), fluorescein (FLU), and 4',6-diamidino-2-phenylindole (DAPI), was achieved with this self-powered drug-release system. DAPI released in situ in cell culture media was incorporated into retinal pigment epithelium (RPE) cells. This work demonstrates a proof-of-concept responsive drug-release system that may be used in implantable devices.
Collapse
Affiliation(s)
- Xinxin Xiao
- Department of Chemical Sciences and Bernal Institute, University of Limerick, Limerick V94 T9PX, Ireland.,Department of Chemistry, Technical University of Denmark, Kongens Lyngby 2800, Denmark
| | - Kieran Denis McGourty
- Department of Chemical Sciences and Bernal Institute, University of Limerick, Limerick V94 T9PX, Ireland.,Department of Chemical Sciences and Health Research Institute, University of Limerick, Limerick V94 T9PX, Ireland
| | - Edmond Magner
- Department of Chemical Sciences and Bernal Institute, University of Limerick, Limerick V94 T9PX, Ireland
| |
Collapse
|
30
|
Otero F, Magner E. Biosensors-Recent Advances and Future Challenges in Electrode Materials. SENSORS (BASEL, SWITZERLAND) 2020; 20:E3561. [PMID: 32586032 PMCID: PMC7349852 DOI: 10.3390/s20123561] [Citation(s) in RCA: 37] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/29/2020] [Revised: 06/17/2020] [Accepted: 06/19/2020] [Indexed: 12/15/2022]
Abstract
Electrochemical biosensors benefit from the simplicity, sensitivity, and rapid response of electroanalytical devices coupled with the selectivity of biorecognition molecules. The implementation of electrochemical biosensors in a clinical analysis can provide a sensitive and rapid response for the analysis of biomarkers, with the most successful being glucose sensors for diabetes patients. This review summarizes recent work on the use of structured materials such as nanoporous metals, graphene, carbon nanotubes, and ordered mesoporous carbon for biosensing applications. We also describe the use of additive manufacturing (AM) and review recent progress and challenges for the use of AM in biosensing applications.
Collapse
Affiliation(s)
| | - Edmond Magner
- Department of Chemical Sciences and Bernal Institute, University of Limerick, V94 T9PX Limerick, Ireland;
| |
Collapse
|
31
|
Bocchetta P, Frattini D, Ghosh S, Mohan AMV, Kumar Y, Kwon Y. Soft Materials for Wearable/Flexible Electrochemical Energy Conversion, Storage, and Biosensor Devices. MATERIALS (BASEL, SWITZERLAND) 2020; 13:E2733. [PMID: 32560176 PMCID: PMC7345738 DOI: 10.3390/ma13122733] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/14/2020] [Revised: 06/08/2020] [Accepted: 06/12/2020] [Indexed: 02/07/2023]
Abstract
Next-generation wearable technology needs portable flexible energy storage, conversion, and biosensor devices that can be worn on soft and curved surfaces. The conformal integration of these devices requires the use of soft, flexible, light materials, and substrates with similar mechanical properties as well as high performances. In this review, we have collected and discussed the remarkable research contributions of recent years, focusing the attention on the development and arrangement of soft and flexible materials (electrodes, electrolytes, substrates) that allowed traditional power sources and sensors to become viable and compatible with wearable electronics, preserving or improving their conventional performances.
Collapse
Affiliation(s)
- Patrizia Bocchetta
- Dipartimento di Ingegneria dell’Innovazione, Università del Salento, via Monteroni, 73100 Lecce, Italy
| | - Domenico Frattini
- Graduate School of Energy and Environment, Seoul National University of Science and Technology, 232 Gongneung-ro, Nowon-gu, Seoul 01811, Korea;
| | - Srabanti Ghosh
- Department of Organic and Inorganic Chemistry, Universidad de Alcala (UAH), Alcalá de Henares, 28805 Madrid, Spain;
| | - Allibai Mohanan Vinu Mohan
- Electrodics and Electrocatalysis Division, CSIR-Central Electrochemical Research Institute (CECRI), Karaikudi, Tamil Nadu 630003, India;
| | - Yogesh Kumar
- Department of Physics, ARSD College, University of Delhi, Delhi 110021, India;
| | - Yongchai Kwon
- Graduate School of Energy and Environment, Seoul National University of Science and Technology, 232 Gongneung-ro, Nowon-gu, Seoul 01811, Korea;
- Department of Chemical and Biomolecular Engineering, Seoul National University of Science and Technology, 232 Gongneung-ro, Nowon-gu, Seoul 01811, Korea
| |
Collapse
|
32
|
Improved operational stability of mediated glucose enzyme electrodes for operation in human physiological solutions. Bioelectrochemistry 2020; 133:107460. [DOI: 10.1016/j.bioelechem.2020.107460] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2019] [Revised: 01/09/2020] [Accepted: 01/09/2020] [Indexed: 11/20/2022]
|
33
|
Tang J, Yan X, Engelbrekt C, Ulstrup J, Magner E, Xiao X, Zhang J. Development of graphene-based enzymatic biofuel cells: A minireview. Bioelectrochemistry 2020; 134:107537. [PMID: 32361268 DOI: 10.1016/j.bioelechem.2020.107537] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2020] [Revised: 04/15/2020] [Accepted: 04/15/2020] [Indexed: 12/24/2022]
Abstract
Enzymatic biofuel cells (EBFCs) have attracted increasing attention due to their potential to harvest energy from a wide range of fuels under mild conditions. Fabrication of effective bioelectrodes is essential for the practical application of EBFCs. Graphene possesses unique physiochemical properties making it an attractive material for the construction of EBFCs. Despite these promising properties, graphene has not been used for EBFCs as frequently as carbon nanotubes, another nanoscale carbon allotrope. This review focuses on current research progress in graphene-based electrodes, including electrodes modified with graphene derivatives and graphene composites, as well as free-standing graphene electrodes. Particular features of graphene-based electrodes such as high conductivity, mechanical flexibility and high porosity for bioelectrochemical applications are highlighted. Reports on graphene-based EBFCs from the last five years are summarized, and perspectives for graphene-based EBFCs are offered.
Collapse
Affiliation(s)
- Jing Tang
- Department of Chemistry, Technical University of Denmark, Kongens Lyngby 2800, Denmark
| | - Xiaomei Yan
- Department of Chemistry, Technical University of Denmark, Kongens Lyngby 2800, Denmark
| | - Christian Engelbrekt
- Department of Chemistry, Technical University of Denmark, Kongens Lyngby 2800, Denmark
| | - Jens Ulstrup
- Department of Chemistry, Technical University of Denmark, Kongens Lyngby 2800, Denmark; Kazan National Research Technological University, K. Marx Str., 68, 420015 Kazan, Republic of Tatarstan, Russian Federation
| | - Edmond Magner
- Department of Chemical Sciences and Bernal Institute, University of Limerick, Limerick V94 T9PX, Ireland
| | - Xinxin Xiao
- Department of Chemistry, Technical University of Denmark, Kongens Lyngby 2800, Denmark.
| | - Jingdong Zhang
- Department of Chemistry, Technical University of Denmark, Kongens Lyngby 2800, Denmark.
| |
Collapse
|
34
|
Bollella P. Porous Gold: A New Frontier for Enzyme-Based Electrodes. NANOMATERIALS (BASEL, SWITZERLAND) 2020; 10:E722. [PMID: 32290306 PMCID: PMC7221854 DOI: 10.3390/nano10040722] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/05/2020] [Revised: 04/01/2020] [Accepted: 04/08/2020] [Indexed: 12/23/2022]
Abstract
Porous gold (PG) layers modified electrodes have emerged as valuable enzyme support to realize multiple enzyme-based bioelectrochemical devices like biosensors, enzymatic fuel cells (EFCs), smart drug delivery devices triggered by enzyme catalyzed reactions, etc. PG films can be synthesized by using different methods such as dealloying, electrochemical (e.g., templated electrochemical deposition, self-templated electrochemical deposition, etc.) self-assembly and sputter deposition. This review aims to summarize the recent findings about PG synthesis and electrosynthesis, its characterization and application for enzyme-based electrodes used for biosensors and enzymatic fuel cells (EFCs) development.
Collapse
Affiliation(s)
- Paolo Bollella
- Department of Chemistry and Biomolecular Science, Clarkson University, Potsdam, 13699-5810 NY, USA
| |
Collapse
|
35
|
Keum DH, Kim SK, Koo J, Lee GH, Jeon C, Mok JW, Mun BH, Lee KJ, Kamrani E, Joo CK, Shin S, Sim JY, Myung D, Yun SH, Bao Z, Hahn SK. Wireless smart contact lens for diabetic diagnosis and therapy. SCIENCE ADVANCES 2020; 6:eaba3252. [PMID: 32426469 PMCID: PMC7182412 DOI: 10.1126/sciadv.aba3252] [Citation(s) in RCA: 172] [Impact Index Per Article: 43.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/23/2019] [Accepted: 01/31/2020] [Indexed: 05/21/2023]
Abstract
A smart contact lens can be used as an excellent interface between the human body and an electronic device for wearable healthcare applications. Despite wide investigations of smart contact lenses for diagnostic applications, there has been no report on electrically controlled drug delivery in combination with real-time biometric analysis. Here, we developed smart contact lenses for both continuous glucose monitoring and treatment of diabetic retinopathy. The smart contact lens device, built on a biocompatible polymer, contains ultrathin, flexible electrical circuits and a microcontroller chip for real-time electrochemical biosensing, on-demand controlled drug delivery, wireless power management, and data communication. In diabetic rabbit models, we could measure tear glucose levels to be validated by the conventional invasive blood glucose tests and trigger drugs to be released from reservoirs for treating diabetic retinopathy. Together, we successfully demonstrated the feasibility of smart contact lenses for noninvasive and continuous diabetic diagnosis and diabetic retinopathy therapy.
Collapse
Affiliation(s)
- Do Hee Keum
- Department of Materials Science and Engineering, Pohang University of Science and Technology (POSTECH), 77 Cheongam-ro, Nam-gu, Pohang, Gyeongbuk 37673, Korea
| | - Su-Kyoung Kim
- Department of Materials Science and Engineering, Pohang University of Science and Technology (POSTECH), 77 Cheongam-ro, Nam-gu, Pohang, Gyeongbuk 37673, Korea
| | - Jahyun Koo
- Department of Electrical Engineering, Pohang University of Science and Technology (POSTECH), 77 Cheongam-ro, Nam-gu, Pohang, Gyeongbuk 37673, Korea
| | - Geon-Hui Lee
- Department of Materials Science and Engineering, Pohang University of Science and Technology (POSTECH), 77 Cheongam-ro, Nam-gu, Pohang, Gyeongbuk 37673, Korea
| | - Cheonhoo Jeon
- Department of Electrical Engineering, Pohang University of Science and Technology (POSTECH), 77 Cheongam-ro, Nam-gu, Pohang, Gyeongbuk 37673, Korea
| | - Jee Won Mok
- Department of Ophthalmology and Visual Science, Seoul St. Mary’s Hospital, College of Medicine, The Catholic University of Korea, 505, Banpo-dong, Seocho-gu, Seoul 06591, Korea
| | - Beom Ho Mun
- Department of Materials Science and Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon 34141, Korea
| | - Keon Jae Lee
- Department of Materials Science and Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon 34141, Korea
| | - Ehsan Kamrani
- Wellman Center for Photomedicine, Massachusetts General Hospital and Harvard Medical School, 65 Landsdowne St., UP-5, Cambridge, MA 02139, USA
| | - Choun-Ki Joo
- Department of Ophthalmology and Visual Science, Seoul St. Mary’s Hospital, College of Medicine, The Catholic University of Korea, 505, Banpo-dong, Seocho-gu, Seoul 06591, Korea
| | - Sangbaie Shin
- PHI BIOMED Co., #613, 12 Gangnam-daero 65-gil, Seocho-gu, Seoul 06612, Korea
| | - Jae-Yoon Sim
- Department of Electrical Engineering, Pohang University of Science and Technology (POSTECH), 77 Cheongam-ro, Nam-gu, Pohang, Gyeongbuk 37673, Korea
| | - David Myung
- Department of Chemical Engineering, Stanford University, 443 Via Ortega, Stanford, CA 94305, USA
- Byers Eye Institute at Stanford University School of Medicine, Palo Alto, CA 94304, USA
| | - Seok Hyun Yun
- Wellman Center for Photomedicine, Massachusetts General Hospital and Harvard Medical School, 65 Landsdowne St., UP-5, Cambridge, MA 02139, USA
| | - Zhenan Bao
- Department of Chemical Engineering, Stanford University, 443 Via Ortega, Stanford, CA 94305, USA
| | - Sei Kwang Hahn
- Department of Materials Science and Engineering, Pohang University of Science and Technology (POSTECH), 77 Cheongam-ro, Nam-gu, Pohang, Gyeongbuk 37673, Korea
- PHI BIOMED Co., #613, 12 Gangnam-daero 65-gil, Seocho-gu, Seoul 06612, Korea
- Department of Chemical Engineering, Stanford University, 443 Via Ortega, Stanford, CA 94305, USA
- Corresponding author.
| |
Collapse
|
36
|
Shrivastava S, Trung TQ, Lee NE. Recent progress, challenges, and prospects of fully integrated mobile and wearable point-of-care testing systems for self-testing. Chem Soc Rev 2020; 49:1812-1866. [PMID: 32100760 DOI: 10.1039/c9cs00319c] [Citation(s) in RCA: 217] [Impact Index Per Article: 54.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
The rapid growth of research in the areas of chemical and biochemical sensors, lab-on-a-chip, mobile technology, and wearable electronics offers an unprecedented opportunity in the development of mobile and wearable point-of-care testing (POCT) systems for self-testing. Successful implementation of such POCT technologies leads to minimal user intervention during operation to reduce user errors; user-friendly, easy-to-use and simple detection platforms; high diagnostic sensitivity and specificity; immediate clinical assessment; and low manufacturing and consumables costs. In this review, we discuss recent developments in the field of highly integrated mobile and wearable POCT systems. In particular, aspects of sample handling platforms, recognition elements and sensing methods, and new materials for signal transducers and powering devices for integration into mobile or wearable POCT systems will be highlighted. We also summarize current challenges and future prospects for providing personal healthcare with sample-in result-out mobile and wearable POCT.
Collapse
Affiliation(s)
- Sajal Shrivastava
- School of Advanced Materials Science & Engineering, Sungkyunkwan University, Suwon, Gyeonggi-do 16419, Korea.
| | | | | |
Collapse
|
37
|
Verho O, Bäckvall JE. Nanocatalysis Meets Biology. TOP ORGANOMETAL CHEM 2020. [DOI: 10.1007/3418_2020_38] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
38
|
Challenges and Opportunities of Carbon Nanomaterials for Biofuel Cells and Supercapacitors: Personalized Energy for Futuristic Self-Sustainable Devices. C — JOURNAL OF CARBON RESEARCH 2019. [DOI: 10.3390/c5040062] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Various carbon allotropes are fundamental components in electrochemical energy-conversion and energy-storage devices, e.g., biofuel cells (BFCs) and supercapacitors. Recently, biodevices, particularly wearable and implantable devices, are of distinct interest in biomedical, fitness, academic, and industrial fields due to their new fascinating capabilities for personalized applications. However, all biodevices require a sustainable source of energy, bringing widespread attention to energy research. In this review, we detail the progress in BFCs and supercapacitors attributed to carbon materials. Self-powered biosensors for futuristic biomedical applications are also featured. To develop these energy devices, many challenges needed to be addressed. For this reason, there is a need to: optimize the electron transfer between the enzymatic site and electrode; enhance the power efficiency of the device in fluctuating oxygen conditions; strengthen the efficacy of enzymatic reactions at the carbon-based electrodes; increase the electrochemically accessible surface area of the porous electrode materials; and refine the flexibility of traditional devices by introducing a mechanical resiliency of electrochemical devices to withstand daily multiplexed movements. This article will also feature carbon nanomaterial research alongside opportunities to enhance energy technology and address the challenges facing the field of personalized applications. Carbon-based energy devices have proved to be sustainable and compatible energy alternatives for biodevices within the human body, serving as attractive options for further developing diverse domains, including individual biomedical applications.
Collapse
|
39
|
Khan RK, Yadavalli VK, Collinson MM. Flexible Nanoporous Gold Electrodes for Electroanalysis in Complex Matrices. ChemElectroChem 2019. [DOI: 10.1002/celc.201900894] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Affiliation(s)
- Rezaul K. Khan
- Department of Chemistry Virginia Commonwealth University Richmond, VA 23284-2006
| | - Vamsi K. Yadavalli
- Department of Chemical and Life Science Engineering Virginia Commonwealth University Richmond, VA 23284
| | - Maryanne M Collinson
- Department of Chemistry Virginia Commonwealth University Richmond, VA 23284-2006
| |
Collapse
|
40
|
Moreddu R, Vigolo D, Yetisen AK. Contact Lens Technology: From Fundamentals to Applications. Adv Healthc Mater 2019; 8:e1900368. [PMID: 31183972 DOI: 10.1002/adhm.201900368] [Citation(s) in RCA: 109] [Impact Index Per Article: 21.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2019] [Revised: 05/20/2019] [Indexed: 12/29/2022]
Abstract
Contact lenses are ocular prosthetic devices used by over 150 million people worldwide. Primary applications of contact lenses include vision correction, therapeutics, and cosmetics. Contact lens materials have significantly evolved over time to minimize adverse effects associated with contact lens wearing, to maintain a regular corneal metabolism, and to preserve tear film stability. This article encompasses contact lens technology, including materials, chemical and physical properties, manufacturing processes, microbial contamination, and ocular complications. The function and the composition of the tear fluid are discussed to assess its potential as a diagnostic media. The regulatory standards of contact lens devices with regard to biocompatibility and contact lens market are presented. Future prospects in contact lens technology are evaluated, with particular interest given to theranostic applications for in situ continuous monitoring the ocular physiology.
Collapse
Affiliation(s)
- Rosalia Moreddu
- Department of Chemical EngineeringImperial College London SW7 2AZ London UK
- School of Chemical EngineeringUniversity of Birmingham B15 2TT Birmingham UK
| | - Daniele Vigolo
- School of Chemical EngineeringUniversity of Birmingham B15 2TT Birmingham UK
| | - Ali K. Yetisen
- Department of Chemical EngineeringImperial College London SW7 2AZ London UK
| |
Collapse
|
41
|
Performance of a glucose-reactive enzyme-based biofuel cell system for biomedical applications. Sci Rep 2019; 9:10872. [PMID: 31350441 PMCID: PMC6659637 DOI: 10.1038/s41598-019-47392-1] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2019] [Accepted: 07/16/2019] [Indexed: 01/12/2023] Open
Abstract
A glucose-reactive enzyme-based biofuel cell system (EBFC) was recently introduced in the scientific community for biomedical applications, such as implantable artificial organs and biosensors for drug delivery. Upon direct contact with tissues or organs, an implanted EBFC can exert effects that damage or stimulate intact tissue due to its byproducts or generated electrical cues, which have not been investigated in detail. Here, we perform a fundamental cell culture study using a glucose dehydrogenase (GDH) as an anode enzyme and bilirubin oxidase (BOD) as a cathode enzyme. The fabricated EBFC had power densities of 15.26 to 38.33 nW/cm2 depending on the enzyme concentration in media supplemented with 25 mM glucose. Despite the low power density, the GDH-based EBFC showed increases in cell viability (~150%) and cell migration (~90%) with a relatively low inflammatory response. However, glucose oxidase (GOD), which has been used as an EBFC anode enzyme, revealed extreme cytotoxicity (~10%) due to the lethal concentration of H2O2 byproducts (~1500 µM). Therefore, with its cytocompatibility and cell-stimulating effects, the GDH-based EBFC is considered a promising implantable tool for generating electricity for biomedical applications. Finally, the GDH-based EBFC can be used for introducing electricity during cell culture and the fabrication of organs on a chip and a power source for implantable devices such as biosensors, biopatches, and artificial organs.
Collapse
|
42
|
Xiao X, Xia HQ, Wu R, Bai L, Yan L, Magner E, Cosnier S, Lojou E, Zhu Z, Liu A. Tackling the Challenges of Enzymatic (Bio)Fuel Cells. Chem Rev 2019; 119:9509-9558. [PMID: 31243999 DOI: 10.1021/acs.chemrev.9b00115] [Citation(s) in RCA: 180] [Impact Index Per Article: 36.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
The ever-increasing demands for clean and sustainable energy sources combined with rapid advances in biointegrated portable or implantable electronic devices have stimulated intensive research activities in enzymatic (bio)fuel cells (EFCs). The use of renewable biocatalysts, the utilization of abundant green, safe, and high energy density fuels, together with the capability of working at modest and biocompatible conditions make EFCs promising as next generation alternative power sources. However, the main challenges (low energy density, relatively low power density, poor operational stability, and limited voltage output) hinder future applications of EFCs. This review aims at exploring the underlying mechanism of EFCs and providing possible practical strategies, methodologies and insights to tackle these issues. First, this review summarizes approaches in achieving high energy densities in EFCs, particularly, employing enzyme cascades for the deep/complete oxidation of fuels. Second, strategies for increasing power densities in EFCs, including increasing enzyme activities, facilitating electron transfers, employing nanomaterials, and designing more efficient enzyme-electrode interfaces, are described. The potential of EFCs/(super)capacitor combination is discussed. Third, the review evaluates a range of strategies for improving the stability of EFCs, including the use of different enzyme immobilization approaches, tuning enzyme properties, designing protective matrixes, and using microbial surface displaying enzymes. Fourth, approaches for the improvement of the cell voltage of EFCs are highlighted. Finally, future developments and a prospective on EFCs are envisioned.
Collapse
Affiliation(s)
- Xinxin Xiao
- Institute for Biosensing, and College of Life Sciences , Qingdao University , 308 Ningxia Road , Qingdao 266071 , China.,Department of Chemical Sciences and Bernal Institute , University of Limerick , Limerick V94 T9PX , Ireland
| | - Hong-Qi Xia
- Institute for Biosensing, and College of Life Sciences , Qingdao University , 308 Ningxia Road , Qingdao 266071 , China
| | - Ranran Wu
- Tianjin Institute of Industrial Biotechnology, Chinese Academy of Sciences , 32 West seventh Road, Tianjin Airport Economic Area , Tianjin 300308 , China
| | - Lu Bai
- Institute for Biosensing, and College of Life Sciences , Qingdao University , 308 Ningxia Road , Qingdao 266071 , China
| | - Lu Yan
- Institute for Biosensing, and College of Life Sciences , Qingdao University , 308 Ningxia Road , Qingdao 266071 , China
| | - Edmond Magner
- Department of Chemical Sciences and Bernal Institute , University of Limerick , Limerick V94 T9PX , Ireland
| | - Serge Cosnier
- Université Grenoble-Alpes , DCM UMR 5250, F-38000 Grenoble , France.,Département de Chimie Moléculaire , UMR CNRS, DCM UMR 5250, F-38000 Grenoble , France
| | - Elisabeth Lojou
- Aix Marseille Univ, CNRS, BIP, Bioénergétique et Ingénierie des Protéines UMR7281 , Institut de Microbiologie de la Méditerranée, IMM , FR 3479, 31, chemin Joseph Aiguier 13402 Marseille , Cedex 20 , France
| | - Zhiguang Zhu
- Tianjin Institute of Industrial Biotechnology, Chinese Academy of Sciences , 32 West seventh Road, Tianjin Airport Economic Area , Tianjin 300308 , China
| | - Aihua Liu
- Institute for Biosensing, and College of Life Sciences , Qingdao University , 308 Ningxia Road , Qingdao 266071 , China.,College of Chemistry & Chemical Engineering , Qingdao University , 308 Ningxia Road , Qingdao 266071 , China.,School of Pharmacy, Medical College , Qingdao University , Qingdao 266021 , China
| |
Collapse
|
43
|
Tang J, Werchmeister RML, Preda L, Huang W, Zheng Z, Leimkühler S, Wollenberger U, Xiao X, Engelbrekt C, Ulstrup J, Zhang J. Three-Dimensional Sulfite Oxidase Bioanodes Based on Graphene Functionalized Carbon Paper for Sulfite/O2 Biofuel Cells. ACS Catal 2019. [DOI: 10.1021/acscatal.9b01715] [Citation(s) in RCA: 29] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Affiliation(s)
- Jing Tang
- Department of Chemistry, Technical University of Denmark, 2800 Kongens Lyngby, Denmark
| | | | - Loredana Preda
- Department of Molecular Enzymology, University of Potsdam, 14476 Potsdam−Golm, Germany
- Institute of Physical Chemistry of the Romanian Academy, 202 Spl. Independentei, 060021 Bucharest, Romania
| | - Wei Huang
- Department of Chemistry, Technical University of Denmark, 2800 Kongens Lyngby, Denmark
| | - Zhiyong Zheng
- Department of Chemistry, Technical University of Denmark, 2800 Kongens Lyngby, Denmark
| | - Silke Leimkühler
- Department of Molecular Enzymology, University of Potsdam, 14476 Potsdam−Golm, Germany
| | - Ulla Wollenberger
- Department of Molecular Enzymology, University of Potsdam, 14476 Potsdam−Golm, Germany
| | - Xinxin Xiao
- Department of Chemistry, Technical University of Denmark, 2800 Kongens Lyngby, Denmark
| | - Christian Engelbrekt
- Department of Chemistry, Technical University of Denmark, 2800 Kongens Lyngby, Denmark
| | - Jens Ulstrup
- Department of Chemistry, Technical University of Denmark, 2800 Kongens Lyngby, Denmark
| | - Jingdong Zhang
- Department of Chemistry, Technical University of Denmark, 2800 Kongens Lyngby, Denmark
| |
Collapse
|
44
|
Krikstolaityte V, Hamit-Eminovski J, Abariute L, Niaura G, Meskys R, Arnebrant T, Lisak G, Ruzgas T. Impact of molecular linker size on physicochemical properties of assembled gold nanoparticle mono-/multi-layers and their applicability for functional binding of biomolecules. J Colloid Interface Sci 2019; 543:307-316. [PMID: 30825679 DOI: 10.1016/j.jcis.2019.02.048] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2018] [Revised: 02/11/2019] [Accepted: 02/16/2019] [Indexed: 11/29/2022]
Abstract
In this work the impact of molecular inter-linker size on gold nanoparticle (AuNP) mono-/multilayer structural properties, density and homogeneity has been investigated. These characteristics are of great importance for functional binding of biomolecules. Positively charged high or low molecular weight inter-linkers, poly-L-lysine (PLL) or N-(6-mercapto)hexylpyridinium (MHP), were used to attach negatively charged AuNPs on a planar gold surface as well as to further interlink into a multilayer structure via layer-by-layer deposition. The inter-particle interaction within the assembled AuNP films was adjusted by the ionic strength in the AuNPs dispersions. The AuNP layer density and structural/viscoelastic properties were evaluated by the quartz crystal microbalance with dissipation (QCM-D) technique. The validity of the commercial Voigt model, specifically developed for quantitative QCM-D data analysis of homogeneous viscoelastic films, was evaluated by a model independent analysis when comparing the assembled AuNP films with a homogeneous layer of a mucin from bovine submaxillary glands. Both AuNP mono- and multilayers, attached/interlinked via long flexible PLL molecules assembled to denser and more soft/viscous structures compared to those interlinked by short MHP compounds. Thus, PLL-interlinked AuNP mono-/multilayer structures were further investigated as a platform for laccase enzyme functional adsorption via qualitative assessment of bioelectrochemical characteristics of the enzyme.
Collapse
Affiliation(s)
- Vida Krikstolaityte
- School of Civil and Environmental Engineering, Nanyang Technological University, 50 Nanyang Ave, 639798 Singapore, Singapore; Residues and Resource Reclamation Centre (R3C), Nanyang Environment and Water Research Institute (NEWRI), Nanyang Technological University, CleanTech One, 637141Singapore, Singapore; Department of Biomedical Science & Biofilms-Research Center for Biointerfaces, Malmö University, 205 06 Malmö, Sweden.
| | - Jildiz Hamit-Eminovski
- Department of Biomedical Science & Biofilms-Research Center for Biointerfaces, Malmö University, 205 06 Malmö, Sweden
| | - Laura Abariute
- Department of Biomedical Science & Biofilms-Research Center for Biointerfaces, Malmö University, 205 06 Malmö, Sweden; Division of Solid State Physics, NanoLund, Lund University, 221 00 Lund, Sweden
| | - Gediminas Niaura
- Department of Organic Chemistry, Center for Physical Sciences and Technology, Sauletekio 3, LT-10257 Vilnius, Lithuania
| | - Rolandas Meskys
- Department of Molecular Microbiology and Biotechnology, Institute of Biochemistry, Life Sciences Center, Vilnius University, Sauletekio 7, LT-10257 Vilnius, Lithuania
| | - Thomas Arnebrant
- Department of Biomedical Science & Biofilms-Research Center for Biointerfaces, Malmö University, 205 06 Malmö, Sweden
| | - Grzegorz Lisak
- School of Civil and Environmental Engineering, Nanyang Technological University, 50 Nanyang Ave, 639798 Singapore, Singapore; Residues and Resource Reclamation Centre (R3C), Nanyang Environment and Water Research Institute (NEWRI), Nanyang Technological University, CleanTech One, 637141Singapore, Singapore.
| | - Tautgirdas Ruzgas
- Department of Biomedical Science & Biofilms-Research Center for Biointerfaces, Malmö University, 205 06 Malmö, Sweden.
| |
Collapse
|
45
|
Effect of individual plasma components on the performance of a glucose enzyme electrode based on redox polymer mediation of a flavin adenine dinucleotide-dependent glucose dehydrogenase. Electrochim Acta 2019. [DOI: 10.1016/j.electacta.2019.02.039] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
46
|
Kang Z, Job Zhang YHP, Zhu Z. A shriveled rectangular carbon tube with the concave surface for high-performance enzymatic glucose/O 2 biofuel cells. Biosens Bioelectron 2019; 132:76-83. [PMID: 30856430 DOI: 10.1016/j.bios.2019.02.044] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2018] [Revised: 02/13/2019] [Accepted: 02/21/2019] [Indexed: 12/15/2022]
Abstract
In this study, a novel carbon tube was prepared by carbonizing a rectangular polypyrrole (RPPy) tube at a high temperature for the construction of enzymatic biofuel cells with high performance. SEM and TEM images clearly showed that the initial PPy presented a rectangular tube shape, while the carbonized PPy became a shriveled rectangular tube with a concave surface, which might be beneficial for enzyme immobilization and electrochemical applications. The glucose oxidase (GOx)- or laccase (Lac)-modified electrodes based on carbonized RPPy exhibited excellent bioelectrochemical performance. In addition, a biofuel cell (GOx, glucose/O2, Lac) was assembled, and the open-circuit voltage reached 1.16 V. The maximum power density was measured to 0.350 mW cm-2, which correlated to the gravimetric power density of 0.265 mW mg-1 (per mg of GOx) at 0.85 V. The constant-current discharge method was used to further evaluate the continuous discharge capacity. The discharge time reached 49.9 h at a discharge current of 0.2 mA before the voltage was lower than 0.8 V. Furthermore, three of the fabricated biofuel cells in series were able to continually light up a white light-emitting diode (LED) whose turn-on voltage was ca. 2.4 V for more than 48 h. This study suggests that carbonized conducting polymers may become a useful electrode material for the development of enzymatic biofuel cells.
Collapse
Affiliation(s)
- Zepeng Kang
- Tianjin Institute of Industrial Biotechnology, Chinese Academy of Sciences, 32 West 7th Avenue, Tianjin Airport Economic Area, Tianjin 300308, China
| | - Yi-Heng P Job Zhang
- Tianjin Institute of Industrial Biotechnology, Chinese Academy of Sciences, 32 West 7th Avenue, Tianjin Airport Economic Area, Tianjin 300308, China
| | - Zhiguang Zhu
- Tianjin Institute of Industrial Biotechnology, Chinese Academy of Sciences, 32 West 7th Avenue, Tianjin Airport Economic Area, Tianjin 300308, China.
| |
Collapse
|
47
|
Hui Y, Ma X, Qu F. Flexible glucose/oxygen enzymatic biofuel cells based on three-dimensional gold-coated nickel foam. J Solid State Electrochem 2018. [DOI: 10.1007/s10008-018-4099-4] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
|
48
|
Rewatkar P, Goel S. Paper-Based Membraneless Co-Laminar Microfluidic Glucose Biofuel Cell With MWCNT-Fed Bucky Paper Bioelectrodes. IEEE Trans Nanobioscience 2018; 17:374-379. [DOI: 10.1109/tnb.2018.2857406] [Citation(s) in RCA: 34] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
49
|
Xiao X, Conghaile PÓ, Leech D, Magner E. Use of Polymer Coatings to Enhance the Response of Redox‐Polymer‐Mediated Electrodes. ChemElectroChem 2018. [DOI: 10.1002/celc.201800983] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Affiliation(s)
- Xinxin Xiao
- Department of Chemical Sciences and Bernal InstituteUniversity of Limerick Limerick V94 T9PX Ireland
| | - Peter Ó Conghaile
- School of Chemistry & Ryan InstituteNational University of Ireland Galway Galway Ireland
| | - Dónal Leech
- School of Chemistry & Ryan InstituteNational University of Ireland Galway Galway Ireland
| | - Edmond Magner
- Department of Chemical Sciences and Bernal InstituteUniversity of Limerick Limerick V94 T9PX Ireland
| |
Collapse
|
50
|
Tseng RC, Chen CC, Hsu SM, Chuang HS. Contact-Lens Biosensors. SENSORS (BASEL, SWITZERLAND) 2018; 18:E2651. [PMID: 30104496 PMCID: PMC6111605 DOI: 10.3390/s18082651] [Citation(s) in RCA: 62] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/12/2018] [Revised: 08/06/2018] [Accepted: 08/10/2018] [Indexed: 12/14/2022]
Abstract
Rapid diagnosis and screening of diseases have become increasingly important in predictive and preventive medicine as they improve patient treatment strategies and reduce cost as well as burden on our healthcare system. In this regard, wearable devices are emerging as effective and reliable point-of-care diagnostics that can allow users to monitor their health at home. These wrist-worn, head-mounted, smart-textile, or smart-patches devices can offer valuable information on the conditions of patients as a non-invasive form of monitoring. However, they are significantly limited in monitoring physiological signals and biomechanics, and, mostly, rely on the physical attributes. Recently, developed wearable devices utilize body fluids, such as sweat, saliva, or skin interstitial fluid, and electrochemical interactions to allow continuous physiological condition and disease monitoring for users. Among them, tear fluid has been widely utilized in the investigation of ocular diseases, diabetes, and even cancers, because of its easy accessibility, lower complexity, and minimal invasiveness. By determining the concentration change of analytes within the tear fluid, it would be possible to identify disease progression and allow patient-oriented therapies. Considering the emerging trend of tear-based biosensing technology, this review article aims to focus on an overview of the tear fluid as a detection medium for certain diseases, such as ocular disorders, diabetes, and cancer. In addition, the rise and application of minimally invasive detection and monitoring via integrated contact lens biosensors will also be addressed, in regards to their practicality and current developmental progress.
Collapse
Affiliation(s)
- Ryan Chang Tseng
- Department of Biomedical Engineering, National Cheng Kung University, Tainan City 701, Taiwan.
| | - Ching-Chuen Chen
- Department of Biomedical Engineering, National Cheng Kung University, Tainan City 701, Taiwan.
| | - Sheng-Min Hsu
- Department of Ophthalmology, National Cheng Kung University Hospital, Tainan City 704, Taiwan.
| | - Han-Sheng Chuang
- Department of Biomedical Engineering, National Cheng Kung University, Tainan City 701, Taiwan.
- Medical Device Innovation Center, National Cheng Kung University, Tainan City 701, Taiwan.
| |
Collapse
|