1
|
Wesdemiotis C, Williams-Pavlantos KN, Keating AR, McGee AS, Bochenek C. Mass spectrometry of polymers: A tutorial review. MASS SPECTROMETRY REVIEWS 2024; 43:427-476. [PMID: 37070280 DOI: 10.1002/mas.21844] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/02/2022] [Revised: 03/03/2023] [Accepted: 03/17/2023] [Indexed: 06/19/2023]
Abstract
Ever since the inception of synthetic polymeric materials in the late 19th century, the number of studies on polymers as well as the complexity of their structures have only increased. The development and commercialization of new polymers with properties fine-tuned for specific technological, environmental, consumer, or biomedical applications requires powerful analytical techniques that permit the in-depth characterization of these materials. One such method with the ability to provide chemical composition and structure information with high sensitivity, selectivity, specificity, and speed is mass spectrometry (MS). This tutorial review presents and exemplifies the various MS techniques available for the elucidation of specific structural features in a synthetic polymer, including compositional complexity, primary structure, architecture, topology, and surface properties. Key to every MS analysis is sample conversion to gas-phase ions. This review describes the fundamentals of the most suitable ionization methods for synthetic materials and provides relevant sample preparation protocols. Most importantly, structural characterizations via one-step as well as hyphenated or multidimensional approaches are introduced and demonstrated with specific applications, including surface sensitive and imaging techniques. The aim of this tutorial review is to illustrate the capabilities of MS for the characterization of large, complex polymers and emphasize its potential as a powerful compositional and structural elucidation tool in polymer chemistry.
Collapse
Affiliation(s)
| | | | - Addie R Keating
- Department of Chemistry, The University of Akron, Akron, Ohio, USA
| | - Andrew S McGee
- Department of Chemistry, The University of Akron, Akron, Ohio, USA
| | - Calum Bochenek
- Department of Chemistry, The University of Akron, Akron, Ohio, USA
| |
Collapse
|
2
|
Day EC, Chittari SS, Bogen MP, Knight AS. Navigating the Expansive Landscapes of Soft Materials: A User Guide for High-Throughput Workflows. ACS POLYMERS AU 2023; 3:406-427. [PMID: 38107416 PMCID: PMC10722570 DOI: 10.1021/acspolymersau.3c00025] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/15/2023] [Revised: 11/02/2023] [Accepted: 11/07/2023] [Indexed: 12/19/2023]
Abstract
Synthetic polymers are highly customizable with tailored structures and functionality, yet this versatility generates challenges in the design of advanced materials due to the size and complexity of the design space. Thus, exploration and optimization of polymer properties using combinatorial libraries has become increasingly common, which requires careful selection of synthetic strategies, characterization techniques, and rapid processing workflows to obtain fundamental principles from these large data sets. Herein, we provide guidelines for strategic design of macromolecule libraries and workflows to efficiently navigate these high-dimensional design spaces. We describe synthetic methods for multiple library sizes and structures as well as characterization methods to rapidly generate data sets, including tools that can be adapted from biological workflows. We further highlight relevant insights from statistics and machine learning to aid in data featurization, representation, and analysis. This Perspective acts as a "user guide" for researchers interested in leveraging high-throughput screening toward the design of multifunctional polymers and predictive modeling of structure-property relationships in soft materials.
Collapse
Affiliation(s)
| | | | - Matthew P. Bogen
- Department of Chemistry, The University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27599, United States
| | - Abigail S. Knight
- Department of Chemistry, The University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27599, United States
| |
Collapse
|
3
|
Duez Q, Hoyas S, Josse T, Cornil J, Gerbaux P, De Winter J. Gas-phase structure of polymer ions: Tying together theoretical approaches and ion mobility spectrometry. MASS SPECTROMETRY REVIEWS 2023; 42:1129-1151. [PMID: 34747528 DOI: 10.1002/mas.21745] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/15/2021] [Revised: 08/17/2021] [Accepted: 08/23/2021] [Indexed: 06/07/2023]
Abstract
An increasing number of studies take advantage of ion mobility spectrometry (IMS) coupled to mass spectrometry (IMS-MS) to investigate the spatial structure of gaseous ions. Synthetic polymers occupy a unique place in the field of IMS-MS. Indeed, due to their intrinsic dispersity, they offer a broad range of homologous ions with different lengths. To help rationalize experimental data, various theoretical approaches have been described. First, the study of trend lines is proposed to derive physicochemical and structural parameters. However, the evaluation of data fitting reflects the overall behavior of the ions without reflecting specific information on their conformation. Atomistic simulations constitute another approach that provide accurate information about the ion shape. The overall scope of this review is dedicated to the synergy between IMS-MS and theoretical approaches, including computational chemistry, demonstrating the essential role they play to fully understand/interpret IMS-MS data.
Collapse
Affiliation(s)
- Quentin Duez
- Organic Synthesis and Mass Spectrometry Laboratory, Center of Innovation and Research in Materials and Polymers (CIRMAP), University of Mons, UMONS, Mons, Belgium
- Laboratory for Chemistry of Novel Materials, Center of Innovation and Research in Materials and Polymers (CIRMAP), University of Mons, UMONS, Mons, Belgium
| | - Sébastien Hoyas
- Organic Synthesis and Mass Spectrometry Laboratory, Center of Innovation and Research in Materials and Polymers (CIRMAP), University of Mons, UMONS, Mons, Belgium
- Laboratory for Chemistry of Novel Materials, Center of Innovation and Research in Materials and Polymers (CIRMAP), University of Mons, UMONS, Mons, Belgium
| | | | - Jérôme Cornil
- Laboratory for Chemistry of Novel Materials, Center of Innovation and Research in Materials and Polymers (CIRMAP), University of Mons, UMONS, Mons, Belgium
| | - Pascal Gerbaux
- Organic Synthesis and Mass Spectrometry Laboratory, Center of Innovation and Research in Materials and Polymers (CIRMAP), University of Mons, UMONS, Mons, Belgium
| | - Julien De Winter
- Organic Synthesis and Mass Spectrometry Laboratory, Center of Innovation and Research in Materials and Polymers (CIRMAP), University of Mons, UMONS, Mons, Belgium
| |
Collapse
|
4
|
Hakobyan K, Xu J, Müllner M. The challenges of controlling polymer synthesis at the molecular and macromolecular level. Polym Chem 2022. [DOI: 10.1039/d1py01581h] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
In this Perspective, we outline advances and challenges in controlling the structure of polymers at various size regimes in the context of structural features such as molecular weight distribution, end groups, architecture, composition and sequence.
Collapse
Affiliation(s)
- Karen Hakobyan
- Key Centre for Polymers and Colloids, School of Chemistry, The University of Sydney, Sydney, NSW 2006, Australia
- The University of Sydney Nano Institute (Sydney Nano), Sydney, NSW 2006, Australia
- School of Chemical Engineering, UNSW Sydney, NSW 2052, Australia
| | - Jiangtao Xu
- School of Chemical Engineering, UNSW Sydney, NSW 2052, Australia
| | - Markus Müllner
- Key Centre for Polymers and Colloids, School of Chemistry, The University of Sydney, Sydney, NSW 2006, Australia
- The University of Sydney Nano Institute (Sydney Nano), Sydney, NSW 2006, Australia
| |
Collapse
|
5
|
DeStefano A, Segalman RA, Davidson EC. Where Biology and Traditional Polymers Meet: The Potential of Associating Sequence-Defined Polymers for Materials Science. JACS AU 2021; 1:1556-1571. [PMID: 34723259 PMCID: PMC8549048 DOI: 10.1021/jacsau.1c00297] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/30/2021] [Indexed: 05/08/2023]
Abstract
Polymers with precisely defined monomeric sequences present an exquisite tool for controlling material properties by harnessing both the robustness of synthetic polymers and the ability to tailor the inter- and intramolecular interactions so crucial to many biological materials. While polymer scientists traditionally synthesized and studied the physics of long molecules best described by their statistical nature, many biological polymers derive their highly tailored functions from precisely controlled sequences. Therefore, significant effort has been applied toward developing new methods of synthesizing, characterizing, and understanding the physics of non-natural sequence-defined polymers. This perspective considers the synergistic advantages that can be achieved via tailoring both precise sequence control and attributes of traditional polymers in a single system. Here, we focus on the potential of sequence-defined polymers in highly associating systems, with a focus on the unique properties, such as enhanced proton conductivity, that can be attained by incorporating sequence. In particular, we examine these materials as key model systems for studying previously unresolvable questions in polymer physics including the role of chain shape near interfaces and how to tailor compatibilization between dissimilar polymer blocks. Finally, we discuss the critical challenges-in particular, truly scalable synthetic approaches, characterization and modeling tools, and robust control and understanding of assembly pathways-that must be overcome for sequence-defined polymers to attain their potential and achieve ubiquity.
Collapse
Affiliation(s)
- Audra
J. DeStefano
- Department
of Chemical Engineering, University of California, Santa Barbara, California 93106, United States
| | - Rachel A. Segalman
- Department
of Chemical Engineering, University of California, Santa Barbara, California 93106, United States
- Department
of Materials, University of California, Santa Barbara, California 93106, United States
| | - Emily C. Davidson
- Department
of Chemical and Biological Engineering, Princeton University, Princeton, New Jersey 08544, United States
| |
Collapse
|
6
|
Voeten RC, van de Put B, Jordens J, Mengerink Y, Peters RAH, Haselberg R, Somsen GW. Probing Polyester Branching by Hybrid Trapped Ion-Mobility Spectrometry-Tandem Mass Spectrometry. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2021; 32:1498-1507. [PMID: 33988368 PMCID: PMC8176450 DOI: 10.1021/jasms.1c00071] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/24/2021] [Revised: 04/28/2021] [Accepted: 05/04/2021] [Indexed: 06/12/2023]
Abstract
Trapped ion-mobility spectrometry combined with quadrupole time-of-flight mass spectrometry (TIMS-QTOFMS) was evaluated as a tool for resolving linear and branched isomeric polyester oligomers. Solutions of polyester samples were infused directly into the ion source employing electrospray ionization (ESI). TIMS-MS provides both mobility and m/z data on the formed ions, allowing construction of extracted-ion mobilograms (EIMs). EIMs of polyester molecules showed multimodal patterns, indicating conformational differences among isomers. Subsequent TIMS-MS/MS experiments indicated mobility differences to be caused by (degree of) branching. These assignments were supported by liquid chromatography-TIMS-MS/MS analysis, confirming that direct TIMS-MS provided fast (500 ms/scan) distinction between linear and branched small oligomers. Observing larger oligomers (up to 3000 Da) using TIMS required additional molecular charging to ensure ion entrapment within the mobility window. Molecular supercharging was achieved using m-nitrobenzyl alcohol (NBA). The additional charges on the oligomer structures enhanced mobility separation of isomeric species but also added to the complexity of the obtained fragmentation mass spectra. This complexity could be partly reduced by post-TIMS analyte-decharging applying collision-induced dissociation (CID) prior to Q1 with subsequent isolation of the singly charged ions for further fragmentation. The as-obtained EIM profiles were still quite complex as larger molecules possess more possible structural isomers. Nevertheless, distinguishing between linear and symmetrically branched oligomers was possible based on measured differences in collisional cross sections (CCSs). The established TIMS-QTOFMS approach reliably allows branching information on isomeric polyester molecules up to 3000 Da to be obtained in less than 1 min analysis time.
Collapse
Affiliation(s)
- Robert
L. C. Voeten
- Division
of BioAnalytical Chemistry, Amsterdam Institute of Molecular and Life
Sciences (AIMMS), Vrije Universiteit Amsterdam, de Boelelaan 1085, 1081 HV Amsterdam, The Netherlands
- TI-COAST, Science Park 904, 1098 XH Amsterdam, The Netherlands
- Centre
for Analytical Sciences Amsterdam (CASA), Science Park 904, 1098 XH Amsterdam, The Netherlands
| | - Bram van de Put
- TI-COAST, Science Park 904, 1098 XH Amsterdam, The Netherlands
- Centre
for Analytical Sciences Amsterdam (CASA), Science Park 904, 1098 XH Amsterdam, The Netherlands
| | - Jan Jordens
- DSM
Materials Science Center, Urmonderbaan 22, 6167 MD Geleen, The Netherlands
| | - Ynze Mengerink
- DSM
Materials Science Center, Urmonderbaan 22, 6167 MD Geleen, The Netherlands
| | - Ron A. H. Peters
- Centre
for Analytical Sciences Amsterdam (CASA), Science Park 904, 1098 XH Amsterdam, The Netherlands
- DSM
Resins & Functional Materials, Analytical
Technology Centre, Sluisweg
12, 5145 PE Waalwijk, The Netherlands
- HIMS-Analytical
Chemistry Group, University of Amsterdam, Science Park 904, 1098 XH Amsterdam, The Netherlands
| | - Rob Haselberg
- Division
of BioAnalytical Chemistry, Amsterdam Institute of Molecular and Life
Sciences (AIMMS), Vrije Universiteit Amsterdam, de Boelelaan 1085, 1081 HV Amsterdam, The Netherlands
- Centre
for Analytical Sciences Amsterdam (CASA), Science Park 904, 1098 XH Amsterdam, The Netherlands
| | - Govert W. Somsen
- Division
of BioAnalytical Chemistry, Amsterdam Institute of Molecular and Life
Sciences (AIMMS), Vrije Universiteit Amsterdam, de Boelelaan 1085, 1081 HV Amsterdam, The Netherlands
- Centre
for Analytical Sciences Amsterdam (CASA), Science Park 904, 1098 XH Amsterdam, The Netherlands
| |
Collapse
|
7
|
Austin CA, Inutan ED, Bohrer BC, Li J, Fischer JL, Wijerathne K, Foley CD, Lietz CB, Woodall DW, Imperial LF, Clemmer DE, Trimpin S, Larsen BS. Resolving Isomers of Star-Branched Poly(Ethylene Glycols) by IMS-MS Using Multiply Charged Ions. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2021; 32:21-32. [PMID: 32510213 DOI: 10.1021/jasms.0c00045] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Ion mobility spectrometry (IMS) mass spectrometry (MS) centers on the ability to separate gaseous structures by size, charge, shape, and followed by mass-to-charge (m/z). For oligomeric structures, improved separation is hypothesized to be related to the ability to extend structures through repulsive forces between cations electrostatically bonded to the oligomers. Here we show the ability to separate differently branched multiply charged ions of star-branched poly(ethylene glycol) oligomers (up to 2000 Da) regardless of whether formed by electrospray ionization (ESI) charged solution droplets or from charged solid particles produced directly from a surface by matrix-assisted ionization. Detailed structural characterization of isomers of the star-branched compositions was first established using a home-built high-resolution ESI IMS-MS instrument. The doubly charged ions have well-resolved drift times, achieving separation of isomers and also allowing differentiation of star-branched versus linear oligomers. An IMS-MS "snapshot" approach allows visualization of architectural dispersity and (im)purity of samples in a straightforward manner. Analyses capabilities are shown for different cations and ionization methods using commercially available traveling wave IMS-MS instruments. Analyses directly from surfaces using the new ionization processes are, because of the multiply charging, not only associated with the benefits of improved gas-phase separations, relative to that of ions produced by matrix-assisted laser desorption/ionization, but also provide the potential for spatially resolved measurements relative to ESI and other ionization methods.
Collapse
Affiliation(s)
- Calvin A Austin
- Department of Chemistry, Wayne State University, Detroit, Michigan 48202, United States
| | - Ellen D Inutan
- Department of Chemistry, Wayne State University, Detroit, Michigan 48202, United States
| | - Brian C Bohrer
- Department of Chemistry, Indiana University, Bloomington, Indiana 47405, United States
| | - Jing Li
- Department of Chemistry, Wayne State University, Detroit, Michigan 48202, United States
| | - Joshua L Fischer
- Department of Chemistry, Wayne State University, Detroit, Michigan 48202, United States
| | - Kanchana Wijerathne
- Department of Chemistry, Wayne State University, Detroit, Michigan 48202, United States
| | - Casey D Foley
- Department of Chemistry, Wayne State University, Detroit, Michigan 48202, United States
| | - Christopher B Lietz
- Department of Chemistry, Wayne State University, Detroit, Michigan 48202, United States
| | - Daniel W Woodall
- Department of Chemistry, Wayne State University, Detroit, Michigan 48202, United States
| | - Lorelie F Imperial
- Department of Chemistry, Wayne State University, Detroit, Michigan 48202, United States
| | - David E Clemmer
- Department of Chemistry, Indiana University, Bloomington, Indiana 47405, United States
| | - Sarah Trimpin
- Department of Chemistry, Wayne State University, Detroit, Michigan 48202, United States
| | - Barbara S Larsen
- DuPont, Nutrition & Biosciences, Wilmington, Delaware 19808, United States
| |
Collapse
|
8
|
Haler JRN, Far J, de la Rosa VR, Kune C, Hoogenboom R, De Pauw E. Using Ion Mobility-Mass Spectrometry to Extract Physicochemical Enthalpic and Entropic Contributions from Synthetic Polymers. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2021; 32:330-339. [PMID: 33269928 DOI: 10.1021/jasms.0c00349] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Ion mobility-mass spectrometry (IM-MS) experiments are mostly used hand in hand with computational chemistry to correlate mobility measurements to the shape of the ions. Recently, we developed an automatable method to fit IM data obtained with synthetic homopolymers (i.e., collision cross sections; CCS) without resorting to computational chemistry. Here, we further develop the experimental IM data interpretation to explore physicochemical properties of a series of nine polymers and their monomer units by monitoring the relationship between the CCS and the degree of polymerization (DP). Several remarkable points of the CCS evolutions as a function of the DP were found: the first observed DP of each charge state (ΔDPfirst DP), the DPs constituting the structural rearrangements (ΔDPrearr), and the DPs at the half-rearrangement (DPhalf-rearr). Given that these remarkable points do not rely on absolute CCS values, but on their relative evolution, they can be extracted from CCS or raw IM data without accurate IM calibration. Properties such as coordination numbers of the cations, steric hindrance, or side chain flexibility can be compared. This leads to fit parameter predictions based on the nature of the monomer unit. The interpretation of the fit parameters, extracted using solely experimental data, allows a rapid screening of the properties of the polymers.
Collapse
Affiliation(s)
- Jean R N Haler
- Mass Spectrometry Laboratory, University of Liège, MolSys Research unit, Quartier Agora, Allée du Six Aout 11, B-4000 Liège, Belgium
- LIST - Luxembourg Institute of Science and Technology, Materials Research and Technology Department, 41 rue du Brill, L-4422 Belvaux, Luxembourg
| | - Johann Far
- Mass Spectrometry Laboratory, University of Liège, MolSys Research unit, Quartier Agora, Allée du Six Aout 11, B-4000 Liège, Belgium
| | - Victor R de la Rosa
- Supramolecular Chemistry Group, Centre of Macromolecular Chemistry (CMaC), Department of Organic and Macromolecular Chemistry, Ghent University, Krijgslaan 281 S4, B-9000 Ghent, Belgium
| | - Christopher Kune
- Mass Spectrometry Laboratory, University of Liège, MolSys Research unit, Quartier Agora, Allée du Six Aout 11, B-4000 Liège, Belgium
| | - Richard Hoogenboom
- Supramolecular Chemistry Group, Centre of Macromolecular Chemistry (CMaC), Department of Organic and Macromolecular Chemistry, Ghent University, Krijgslaan 281 S4, B-9000 Ghent, Belgium
| | - Edwin De Pauw
- Mass Spectrometry Laboratory, University of Liège, MolSys Research unit, Quartier Agora, Allée du Six Aout 11, B-4000 Liège, Belgium
| |
Collapse
|
9
|
Chen YH, Lu IC. Novel ion source for a portable mass spectrometer. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2021; 35 Suppl 1:e8503. [PMID: 31197905 DOI: 10.1002/rcm.8503] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/25/2019] [Revised: 05/29/2019] [Accepted: 05/29/2019] [Indexed: 06/09/2023]
Affiliation(s)
- Yi-Hsin Chen
- Department of Chemistry, National Chung Hsing University, Taichung, Taiwan
| | - I-Chung Lu
- Department of Chemistry, National Chung Hsing University, Taichung, Taiwan
| |
Collapse
|
10
|
Duez Q, Moins S, Coulembier O, De Winter J, Cornil J, Gerbaux P. Assessing the Structural Heterogeneity of Isomeric Homo and Copolymers: an Approach Combining Ion Mobility Mass Spectrometry and Molecular Dynamics Simulations. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2020; 31:2379-2388. [PMID: 33044069 DOI: 10.1021/jasms.0c00352] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Synthetic polymers occupy a unique place in the field of ion mobility mass spectrometry (IMS-MS). Indeed, due to their intrinsic dispersity, they have the asset to offer a broad range of homologous ions with different lengths that can be detected in several charge states. In addition, the gas-phase structure of polymer ions mostly depends on their ability to screen the adducted charges. Several works dealing with linear, cyclic, and star-shaped polymers have already shown that the gas-phase structure of polymer ions heavily relies on the polymer architecture, i.e., the primary structure. In the present work, we move a step further by evaluating whether a relationship exists between the primary and secondary structures of synthetic homo and copolymers. The IMS-MS experiments will be further complemented by MD simulations. To highlight the effectiveness of IMS separation, we selected isomeric homo and copolymers made of lactide (LA) and propiolactone (PL) units. In this way, the mass analysis becomes useless since isomeric comonomer sequences can coexist for any given chain length. An UPLC method was implemented in the workflow to successfully separate all PL-LA comonomer sequences before infusion in the IMS-MS instrument. The analysis of doubly charged copolymers showed that the comonomer sequence has an impact on the IMS response. However, this only holds for copolymer ions with precise sizes and charge states, and this is therefore not a rule of thumb.
Collapse
Affiliation(s)
- Quentin Duez
- Organic Synthesis and Mass Spectrometry Laboratory, Center of Innovation and Research in Materials and Polymers (CIRMAP), University of Mons (UMONS), Place du Parc 23, B-7000 Mons, Belgium
- Laboratory for Chemistry of Novel Materials, Center of Innovation and Research in Materials and Polymers (CIRMAP), University of Mons (UMONS), Place du Parc 23, B-7000 Mons, Belgium
| | - Sébastien Moins
- Laboratory of Polymeric and Composite Materials, Center of Innovation and Research in Materials and Polymers (CIRMAP), University of Mons (UMONS), 23 Place du Parc, 7000 Mons, Belgium
| | - Olivier Coulembier
- Laboratory of Polymeric and Composite Materials, Center of Innovation and Research in Materials and Polymers (CIRMAP), University of Mons (UMONS), 23 Place du Parc, 7000 Mons, Belgium
| | - Julien De Winter
- Organic Synthesis and Mass Spectrometry Laboratory, Center of Innovation and Research in Materials and Polymers (CIRMAP), University of Mons (UMONS), Place du Parc 23, B-7000 Mons, Belgium
| | - Jérôme Cornil
- Laboratory for Chemistry of Novel Materials, Center of Innovation and Research in Materials and Polymers (CIRMAP), University of Mons (UMONS), Place du Parc 23, B-7000 Mons, Belgium
| | - Pascal Gerbaux
- Organic Synthesis and Mass Spectrometry Laboratory, Center of Innovation and Research in Materials and Polymers (CIRMAP), University of Mons (UMONS), Place du Parc 23, B-7000 Mons, Belgium
| |
Collapse
|
11
|
Charles L, Chendo C, Poyer S. Ion mobility spectrometry - Mass spectrometry coupling for synthetic polymers. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2020; 34 Suppl 2:e8624. [PMID: 31658387 DOI: 10.1002/rcm.8624] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/02/2019] [Revised: 09/27/2019] [Accepted: 09/28/2019] [Indexed: 06/10/2023]
Abstract
This review covers applications of ion mobility spectrometry (IMS) hyphenated to mass spectrometry (MS) in the field of synthetic polymers. MS has become an essential technique in polymer science, but increasingly complex samples produced to provide desirable macroscopic properties of high-performance materials often require separation of species prior to their mass analysis. Similar to liquid chromatography, the IMS dimension introduces shape selectivity but enables separation at a much faster rate (milliseconds vs minutes). As a post-ionization technique, IMS can be hyphenated to MS to perform a double separation dimension of gas-phase ions, first as a function on their mobility (determined by their charge state and collision cross section, CCS), then as a function of their m/z ratio. Implemented with a variety of ionization techniques, such coupling permits the spectral complexity to be reduced, to enhance the dynamic range of detection, or to achieve separation of isobaric ions prior to their activation in MS/MS experiments. Coupling IMS to MS also provides valuable information regarding the 3D structure of polymer ions in the gas phase and regarding how to address the question of how charges are distributed within the structure. Moreover, the ability of IMS to separate multiply charged species generated by electrospray ionization yields typical IMS-MS 2D maps that permit the conformational dynamics of synthetic polymer chains to be described as a function of their length.
Collapse
Affiliation(s)
- Laurence Charles
- Aix Marseille Univ, CNRS, ICR, Institut de Chimie Radicalaire, 13397, Marseille Cedex 20, France
| | - Christophe Chendo
- Aix Marseille Univ, CNRS, ICR, Institut de Chimie Radicalaire, 13397, Marseille Cedex 20, France
| | - Salomé Poyer
- Aix Marseille Univ, CNRS, ICR, Institut de Chimie Radicalaire, 13397, Marseille Cedex 20, France
| |
Collapse
|
12
|
Inutan ED, Meher AK, Karki S, Fischer JL, Imperial LF, Foley CD, Jarois DR, El-Baba TJ, Lutomski CA, Trimpin S. New mass spectrometry concepts for characterization of synthetic polymers and additives. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2020; 34 Suppl 2:e8768. [PMID: 32107802 DOI: 10.1002/rcm.8768] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/30/2019] [Revised: 02/17/2020] [Accepted: 02/19/2020] [Indexed: 06/10/2023]
Abstract
RATIONALE New ionization processes have been developed for biological mass spectrometry (MS) in which the matrix lifts the nonvolatile analyte into the gas phase as ions without any additional energy input. We rationalized that additional fundamental knowledge is needed to assess analytical utility for the field of synthetic polymers and additives. METHODS Different mass spectrometers (Thermo Orbitrap (Q-)Exactive (Focus); Waters SYNAPT G2(S)) were employed. The formation of multiply charged polymer ions upon exposure of the matrix/analyte(/salt) sample to sub-atmospheric pressure directly from the solid state and surfaces facilitates the use of advanced mass spectrometers for detection of polymeric materials including consumer products (e.g., gum). RESULTS Astonishingly, using nothing more than a small molecule matrix compound (e.g., 2-methyl-2-nitropropane-1,3-diol or 3-nitrobenzonitrile) and a salt (e.g., mono- or divalent cation(s)), such samples upon exposure to sub-atmospheric pressure transfer nonvolatile polymers and nonvolatile salts into the gas phase as multiply charged ions. These successes contradict the conventional understanding of ionization in MS, because can nonvolatile polymers be lifted in the gas phase as ions not only by as little as a volatile matrix but also by the salt required for ionizing the analyte through noncovalent metal cation adduction(s). Prototype vacuum matrix-assisted ionization (vMAI) and automated sources using a contactless approach are demonstrated for direct analyses of synthetic polymers and plasticizers, minimizing the risk of contamination using direct sample introduction into the mass spectrometer vacuum. CONCLUSIONS Direct ionization methods from surfaces without the need of high voltage, a laser, or even applied heat are demonstrated for characterization of detailed materials using (ultra)high-resolution and accurate mass measurements enabled by the multiply charged ions extending the mass range of high-performance mass spectrometers and use of a split probe sample introduction device. Our vision is that, with further development of fundamentals and dedicated sources, both spatial- and temporal-resolution measurements are within reach if sensitivity is addressed for decreasing sample-size measurements.
Collapse
Affiliation(s)
- Ellen D Inutan
- Mindanao State University-Iligan Institute of Technology, Iligan City, Philippines
- Department of Chemistry, Wayne State University, Detroit, MI, USA
- MS™, LLC, Newark, DE, USA
| | - Anil K Meher
- Department of Chemistry, Wayne State University, Detroit, MI, USA
- MS™, LLC, Newark, DE, USA
| | - Santosh Karki
- Department of Chemistry, Wayne State University, Detroit, MI, USA
- MS™, LLC, Newark, DE, USA
| | - Joshua L Fischer
- Department of Chemistry, Wayne State University, Detroit, MI, USA
| | | | - Casey D Foley
- Department of Chemistry, Wayne State University, Detroit, MI, USA
| | - Dean R Jarois
- Department of Chemistry, Wayne State University, Detroit, MI, USA
| | - Tarick J El-Baba
- Department of Chemistry, Wayne State University, Detroit, MI, USA
| | | | - Sarah Trimpin
- Department of Chemistry, Wayne State University, Detroit, MI, USA
- MS™, LLC, Newark, DE, USA
| |
Collapse
|
13
|
Endres KJ, Barthelmes K, Winter A, Antolovich R, Schubert US, Wesdemiotis C. Collision cross-section analysis of self-assembled metallomacrocycle isomers and isobars via ion mobility mass spectrometry. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2020; 34 Suppl 2:e8717. [PMID: 31894612 PMCID: PMC9285404 DOI: 10.1002/rcm.8717] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/01/2019] [Revised: 12/20/2019] [Accepted: 12/27/2019] [Indexed: 05/05/2023]
Abstract
RATIONALE Coordinatively driven self-assembly of transition metal ions and bidentate ligands gives rise to organometallic complexes that usually contain superimposed isobars, isomers, and conformers. In this study, the double dispersion ability of ion mobility mass spectrometry (IM-MS) was used to provide a comprehensive structural characterization of the self-assembled supramolecular complexes by their mass and charge, revealed by the MS event, and their shape and collision cross-section (Ω), revealed by the IM event. METHODS Self-assembled complexes were synthesized by reacting a bis(terpyridine) ligand exhibiting a 60o dihedral angle between the two ligating terpyridine sites (T) with divalent Zn, Ni, Cd, or Fe. The products were isolated as (Metal2+ [T])n (PF6 )2n salts and analyzed using IM-MS after electrospray ionization (ESI) which produced several charge states from each n-mer, depending on the number of PF6 - anions lost upon ESI. Experimental Ω data, derived using IM-MS, and computational Ω predictions were used to elucidate the size and architecture of the complexes. RESULTS Only macrocyclic dimers, trimers, and tetramers were observed with Cd2+ , whereas Zn2+ formed the same plus hexameric complexes. These two metals led to the simplest product distributions and no linear isomers. In sharp contrast, Ni2+ and Fe2+ formed all possible ring sizes from dimer to hexamer as well as various linear isomers. The experimental and theoretical Ω data indicated rather planar macrocyclic geometries for the dimers and trimers, twisted 3D architectures for the larger rings, and substantially larger sizes with spiral conformation for the linear congeners. Adding PF6 - to the same complex was found to mainly cause size contraction due to new stabilizing anion-cation interactions. CONCLUSIONS Complete structural identification could be accomplished using ESI-IM-MS. Our results affirm that self-assembly with Cd2+ and Zn2+ proceeds through reversible equilibria that generate the thermodynamically most stable structures, encompassing exclusively macrocyclic architectures that readily accommodate the 60o ligand used. In contrast, complexation with Ni2+ and Fe2+ , which form stronger coordinative bonds, proceeds through kinetic control, leading to more complex mixtures and kinetically trapped less stable architectures, such as macrocyclic pentamers and linear isomers.
Collapse
Affiliation(s)
| | - Kevin Barthelmes
- Laboratory of Organic and Macromolecular Chemistry (IOMC)Friedrich Schiller University JenaHumboldtstr. 10JenaGermany
- Department of Materials and Applied ChemistryNihon University1‐8‐14 Kanda SurugadaiChiyoda‐kuTokyoJapan
| | - Andreas Winter
- Laboratory of Organic and Macromolecular Chemistry (IOMC)Friedrich Schiller University JenaHumboldtstr. 10JenaGermany
- Jena Center for Soft Matter (JCSM)Friedrich Schiller Universität JenaPhilosophenweg 7JenaGermany
| | | | - Ulrich S. Schubert
- Laboratory of Organic and Macromolecular Chemistry (IOMC)Friedrich Schiller University JenaHumboldtstr. 10JenaGermany
- Jena Center for Soft Matter (JCSM)Friedrich Schiller Universität JenaPhilosophenweg 7JenaGermany
| | - Chrys Wesdemiotis
- Department of Polymer ScienceUniversity of AkronAkronOHUSA
- Department of ChemistryUniversity of AkronAkronOHUSA
| |
Collapse
|
14
|
Haler JRN, Massonnet P, Far J, Upert G, Gilles N, Mourier G, Quinton L, De Pauw E. Can IM-MS Collision Cross Sections of Biomolecules Be Rationalized Using Collision Cross-Section Trends of Polydisperse Synthetic Homopolymers? JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2020; 31:990-995. [PMID: 32233380 DOI: 10.1021/jasms.9b00106] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
In the past, we developed a method inferring physicochemical properties from ion mobility mass spectrometry (IM-MS) data from polydisperse synthetic homopolymers. We extend here the method to biomolecules that are generally monodisperse. Similarities in the IM-MS behavior were illustrated on proteins and peptides. This allows one to identify ionic species for which intramolecular interactions lead to specific structures.
Collapse
Affiliation(s)
- Jean R N Haler
- Mass Spectrometry Laboratory, University of Liège, MolSys Research unit, Quartier Agora, Allée du Six Aout 11, B-4000 Liège, Belgium
| | - Philippe Massonnet
- Mass Spectrometry Laboratory, University of Liège, MolSys Research unit, Quartier Agora, Allée du Six Aout 11, B-4000 Liège, Belgium
- Maastricht Multimodal Molecular Imaging (M4I) Institute, Division of Imaging Mass Spectrometry, 6211 LK Maastricht, The Netherlands
| | - Johann Far
- Mass Spectrometry Laboratory, University of Liège, MolSys Research unit, Quartier Agora, Allée du Six Aout 11, B-4000 Liège, Belgium
| | - Gregory Upert
- Commissariat à l'Energie Atomique CEA, DRF/SIMOPRO, 91191 Gif sur Yvette, France
| | - Nicolas Gilles
- Commissariat à l'Energie Atomique CEA, DRF/SIMOPRO, 91191 Gif sur Yvette, France
| | - Gilles Mourier
- Commissariat à l'Energie Atomique CEA, DRF/SIMOPRO, 91191 Gif sur Yvette, France
| | - Loïc Quinton
- Mass Spectrometry Laboratory, University of Liège, MolSys Research unit, Quartier Agora, Allée du Six Aout 11, B-4000 Liège, Belgium
| | - Edwin De Pauw
- Mass Spectrometry Laboratory, University of Liège, MolSys Research unit, Quartier Agora, Allée du Six Aout 11, B-4000 Liège, Belgium
| |
Collapse
|
15
|
De Bruycker K, Welle A, Hirth S, Blanksby SJ, Barner-Kowollik C. Mass spectrometry as a tool to advance polymer science. Nat Rev Chem 2020; 4:257-268. [PMID: 37127980 DOI: 10.1038/s41570-020-0168-1] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/31/2020] [Indexed: 12/12/2022]
Abstract
In contrast to natural polymers, which have existed for billions of years, the first well-understood synthetic polymers date back to just over one century ago. Nevertheless, this relatively short period has seen vast progress in synthetic polymer chemistry, which can now afford diverse macromolecules with varying structural complexities. To keep pace with this synthetic progress, there have been commensurate developments in analytical chemistry, where mass spectrometry has emerged as the pre-eminent technique for polymer analysis. This Perspective describes present challenges associated with the mass-spectrometric analysis of synthetic polymers, in particular the desorption, ionization and structural interrogation of high-molar-mass macromolecules, as well as strategies to lower spectral complexity. We critically evaluate recent advances in technology in the context of these challenges and suggest how to push the field beyond its current limitations. In this context, the increasingly important role of high-resolution mass spectrometry is emphasized because of its unrivalled ability to describe unique species within polymer ensembles, rather than to report the average properties of the ensemble.
Collapse
|
16
|
Duez Q, Metwally H, Hoyas S, Lemaur V, Cornil J, De Winter J, Konermann L, Gerbaux P. Effects of electrospray mechanisms and structural relaxation on polylactide ion conformations in the gas phase: insights from ion mobility spectrometry and molecular dynamics simulations. Phys Chem Chem Phys 2020; 22:4193-4204. [DOI: 10.1039/c9cp06391a] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
Gas-phase polymer ions may retain structural features associated with their electrospray formation mechanisms.
Collapse
Affiliation(s)
- Quentin Duez
- Organic Synthesis and Mass Spectrometry Laboratory
- Center of Innovation and Research in Materials and Polymers (CIRMAP) – University of Mons (UMONS)
- B-7000 Mons
- Belgium
- Laboratory for Chemistry of Novel Materials
| | - Haidy Metwally
- Department of Chemistry
- The University of Western Ontario
- London
- Canada
| | - Sébastien Hoyas
- Organic Synthesis and Mass Spectrometry Laboratory
- Center of Innovation and Research in Materials and Polymers (CIRMAP) – University of Mons (UMONS)
- B-7000 Mons
- Belgium
- Laboratory for Chemistry of Novel Materials
| | - Vincent Lemaur
- Laboratory for Chemistry of Novel Materials
- Center of Innovation and Research in Materials and Polymers (CIRMAP) – University of Mons (UMONS)
- B-7000 Mons
- Belgium
| | - Jérôme Cornil
- Laboratory for Chemistry of Novel Materials
- Center of Innovation and Research in Materials and Polymers (CIRMAP) – University of Mons (UMONS)
- B-7000 Mons
- Belgium
| | - Julien De Winter
- Organic Synthesis and Mass Spectrometry Laboratory
- Center of Innovation and Research in Materials and Polymers (CIRMAP) – University of Mons (UMONS)
- B-7000 Mons
- Belgium
| | - Lars Konermann
- Department of Chemistry
- The University of Western Ontario
- London
- Canada
| | - Pascal Gerbaux
- Organic Synthesis and Mass Spectrometry Laboratory
- Center of Innovation and Research in Materials and Polymers (CIRMAP) – University of Mons (UMONS)
- B-7000 Mons
- Belgium
| |
Collapse
|
17
|
Mao J, Zhang B, Zhang H, Elupula R, Grayson SM, Wesdemiotis C. Elucidating Branching Topology and Branch Lengths in Star-Branched Polymers by Tandem Mass Spectrometry. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2019; 30:1981-1991. [PMID: 31363988 DOI: 10.1007/s13361-019-02260-0] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/13/2019] [Revised: 05/21/2019] [Accepted: 05/26/2019] [Indexed: 06/10/2023]
Abstract
Tandem mass spectrometry (MS2) has been employed to elucidate the topology and branching architecture of star-branched polyethers. The polymers were ionized by matrix-assisted laser desorption/ionization (MALDI) to positive ions and dissociated after leaving the ion source via laser-induced fragmentation. The bond scissions caused under MALDI-MS2 conditions occur preferentially near the core-branch joining points due to energetically favorable homolytic and heterolytic bond cleavages near the core and release of steric strain and/or reduction of crowding. This unique fragmentation mode detaches complete arms from the core generating fragment ion series at the expected molecular weight of each branch. The number of fragment ion distributions observed combined with their mass-to-charge ratios permit conclusive determination of the degree of branching and the corresponding branch lengths, as demonstrated for differently branched homo- and mikto-arm polyether stars synthesized via azide-alkyne click chemistry. The results of this study underscore the utility of MS2 for the characterization of branching architecture and branch lengths of (co) polymers with two or more linear chains attached to a functionalized central core.
Collapse
Affiliation(s)
- Jialin Mao
- Department of Chemistry, Knight Chemical Laboratory, The University of Akron, Akron, OH, 44325-3601, USA
| | - Boyu Zhang
- Department of Chemistry, Tulane University, New Orleans, LA, 70118, USA
| | - Hong Zhang
- Department of Chemistry, Tulane University, New Orleans, LA, 70118, USA
| | - Ravinder Elupula
- Department of Chemistry, Tulane University, New Orleans, LA, 70118, USA
| | - Scott M Grayson
- Department of Chemistry, Tulane University, New Orleans, LA, 70118, USA
| | - Chrys Wesdemiotis
- Department of Chemistry, Knight Chemical Laboratory, The University of Akron, Akron, OH, 44325-3601, USA.
| |
Collapse
|
18
|
Haler JRN, de la Rosa VR, Massonnet P, Far J, Hoogenboom R, De Pauw E. Fundamental Studies on Poly(2-oxazoline) Side Chain Isomers Using Tandem Mass Spectrometry and Ion Mobility-Mass Spectrometry. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2019; 30:1220-1228. [PMID: 30949970 DOI: 10.1007/s13361-019-02173-y] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/11/2018] [Revised: 02/14/2019] [Accepted: 02/25/2019] [Indexed: 06/09/2023]
Abstract
When polymer mixtures become increasingly complex, the conventional analysis techniques become insufficient for complete characterization. Mass spectrometric techniques can satisfy this increasing demand for detailed sample characterization. Even though isobaric polymers are indistinguishable using simple mass spectrometry (MS) analyses, more advanced techniques such as tandem MS (MS/MS) or ion mobility (IM) can be used. Here, we report proof of concept for characterizing isomeric polymers, namely poly(2-n-propyl-2-oxazoline) (Pn-PrOx) and poly(2-isopropyl-2-oxazoline) (Pi-PrOx), using MS/MS and IM-MS. Pi-PrOx ions lose in intensity at higher accelerating voltages than Pn-PrOx ions during collision-induced dissociation (CID) MS/MS experiments. A Pn/i-PrOx mixture could also be titrated using survival yield calculations of either precursor ions or cation ejection species. IM-MS yielded shape differences in the degree of polymerization (DP) regions showing the structural rearrangements. Combined MS techniques are thus able to identify and deconvolute the molar mass distributions of the two isomers in a mixture. Finally, the MS/MS and IM-MS behaviors are compared for interpretation. Graphical Abstract .
Collapse
Affiliation(s)
- Jean R N Haler
- Mass Spectrometry Laboratory, MolSys Research unit, Quartier Agora, University of Liège, Allée du Six Aout 11, B-4000, Liège, Belgium.
| | - Victor R de la Rosa
- Supramolecular Chemistry Group, Centre of Macromolecular Chemistry (CMaC), Department of Organic and Macromolecular Chemistry, Ghent University, Krijgslaan 281 S4, B-9000, Ghent, Belgium
| | - Philippe Massonnet
- Mass Spectrometry Laboratory, MolSys Research unit, Quartier Agora, University of Liège, Allée du Six Aout 11, B-4000, Liège, Belgium
| | - Johann Far
- Mass Spectrometry Laboratory, MolSys Research unit, Quartier Agora, University of Liège, Allée du Six Aout 11, B-4000, Liège, Belgium
| | - Richard Hoogenboom
- Supramolecular Chemistry Group, Centre of Macromolecular Chemistry (CMaC), Department of Organic and Macromolecular Chemistry, Ghent University, Krijgslaan 281 S4, B-9000, Ghent, Belgium
| | - Edwin De Pauw
- Mass Spectrometry Laboratory, MolSys Research unit, Quartier Agora, University of Liège, Allée du Six Aout 11, B-4000, Liège, Belgium
| |
Collapse
|
19
|
Crescentini TM, May JC, McLean JA, Hercules DM. Alkali Metal Cation Adduct Effect on Polybutylene Adipate Oligomers: Ion Mobility-Mass Spectrometry. POLYMER 2019; 173:58-65. [PMID: 31839686 PMCID: PMC6910660 DOI: 10.1016/j.polymer.2019.04.004] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Polyurethane (PU) di-block copolymers are one of the most versatile polymeric materials, comprised of hard and soft segments that contribute to PU's broad range of applications. Polybutylene adipate (PBA) is a commonly used soft segment in PU systems. Characterizing the structure of PBA polymers is essential to understanding complex heterogeneity within a PU sample. In this study, ion mobility-mass spectrometry (IM-MS) and tandem mass spectrometry (MS/MS) are used to structurally characterize a PBA standard (Mn = 2250) adducted with a combination of monovalent alkali cations (Li, Na, K, Rb, and Cs). IM-MS profiles show unique trends associated with each cation-adducted PBA sample. Charge state trends: +1, +2, and +3 were extracted for cation-adducted PBA oligomers, and investigated to study gas-phase transitional folding. To quantitatively assess the gas-phase structural similarities and differences, a statistical test (ANOVA) was used to compare PBA oligomer-cation collisional cross sections (CCS). Fragmentation studies (MS/MS) identified the unique behavior of Li and Na for promoting 1,5 H-shift and 1,3 H-shift fragmentation, whereas the PBA precursor preferentially loses the larger K, Rb, and Cs cations as the ion activation energy is increased. The combination of adducted alkali cations, IM-MS, and MS/MS allow for unique structural characterization of this important PBA system.
Collapse
Affiliation(s)
- Tiffany M. Crescentini
- Department of Chemistry, Vanderbilt University, Nashville, TN 37240, USA
- Center for Innovative Technology, Vanderbilt University, Nashville, TN 37240, USA
- Institute of Chemical Biology, Vanderbilt University, Nashville, TN 37240, USA
- Institute for Integrated Biosystems Research and Education, Vanderbilt University, Nashville, TN 37240, USA
| | - Jody C. May
- Department of Chemistry, Vanderbilt University, Nashville, TN 37240, USA
- Center for Innovative Technology, Vanderbilt University, Nashville, TN 37240, USA
- Institute of Chemical Biology, Vanderbilt University, Nashville, TN 37240, USA
- Institute for Integrated Biosystems Research and Education, Vanderbilt University, Nashville, TN 37240, USA
| | - John A. McLean
- Department of Chemistry, Vanderbilt University, Nashville, TN 37240, USA
- Center for Innovative Technology, Vanderbilt University, Nashville, TN 37240, USA
- Institute of Chemical Biology, Vanderbilt University, Nashville, TN 37240, USA
- Institute for Integrated Biosystems Research and Education, Vanderbilt University, Nashville, TN 37240, USA
| | - David M. Hercules
- Department of Chemistry, Vanderbilt University, Nashville, TN 37240, USA
| |
Collapse
|
20
|
Duez Q, Liénard R, Moins S, Lemaur V, Coulembier O, Cornil J, Gerbaux P, De Winter J. One Step Further in the Characterization of Synthetic Polymers by Ion Mobility Mass Spectrometry: Evaluating the Contribution of End-groups. Polymers (Basel) 2019; 11:E688. [PMID: 30995722 PMCID: PMC6523221 DOI: 10.3390/polym11040688] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2019] [Revised: 04/09/2019] [Accepted: 04/10/2019] [Indexed: 12/20/2022] Open
Abstract
Several families of polymers possessing various end-groups are characterized by ion mobility mass spectrometry (IMMS). A significant contribution of the end-groups to the ion collision cross section (CCS) is observed, although their role is neglected in current fitting models described in literature. Comparing polymers prepared from different synthetic procedures might thus, be misleading with the current theoretical treatments. We show that this issue is alleviated by comparing the CCS of various polymer ions (polyesters and polyethers) as a function of the number of atoms in the macroion instead of the usual representation involving the degree of polymerization. Finally, we extract the atom number density from the spectra which gives us the possibility to evaluate the compaction of polymer ions, and by extension to discern isomeric polymers.
Collapse
Affiliation(s)
- Quentin Duez
- Organic Synthesis and Mass Spectrometry Laboratory, Interdisciplinary Center for Mass Spectrometry (CISMa), University of Mons, UMONS, 23 Place du Parc, 7000 Mons, Belgium.
- Laboratory for Chemistry of Novel Materials, Center of Innovation and Research in Materials and Polymers (CIRMAP), University of Mons, UMONS, 23 Place du Parc, 7000 Mons, Belgium.
| | - Romain Liénard
- Organic Synthesis and Mass Spectrometry Laboratory, Interdisciplinary Center for Mass Spectrometry (CISMa), University of Mons, UMONS, 23 Place du Parc, 7000 Mons, Belgium.
- Laboratory of Polymeric and Composite Materials, Center of Innovation and Research in Materials and Polymers (CIRMAP), University of Mons, UMONS, 23 Place du Parc, 7000 Mons, Belgium.
| | - Sébastien Moins
- Laboratory of Polymeric and Composite Materials, Center of Innovation and Research in Materials and Polymers (CIRMAP), University of Mons, UMONS, 23 Place du Parc, 7000 Mons, Belgium.
| | - Vincent Lemaur
- Laboratory for Chemistry of Novel Materials, Center of Innovation and Research in Materials and Polymers (CIRMAP), University of Mons, UMONS, 23 Place du Parc, 7000 Mons, Belgium.
| | - Olivier Coulembier
- Laboratory of Polymeric and Composite Materials, Center of Innovation and Research in Materials and Polymers (CIRMAP), University of Mons, UMONS, 23 Place du Parc, 7000 Mons, Belgium.
| | - Jérôme Cornil
- Laboratory for Chemistry of Novel Materials, Center of Innovation and Research in Materials and Polymers (CIRMAP), University of Mons, UMONS, 23 Place du Parc, 7000 Mons, Belgium.
| | - Pascal Gerbaux
- Organic Synthesis and Mass Spectrometry Laboratory, Interdisciplinary Center for Mass Spectrometry (CISMa), University of Mons, UMONS, 23 Place du Parc, 7000 Mons, Belgium.
| | - Julien De Winter
- Organic Synthesis and Mass Spectrometry Laboratory, Interdisciplinary Center for Mass Spectrometry (CISMa), University of Mons, UMONS, 23 Place du Parc, 7000 Mons, Belgium.
| |
Collapse
|
21
|
Haler JR, Morsa D, Lecomte P, Jérôme C, Far J, De Pauw E. Predicting Ion Mobility-Mass Spectrometry trends of polymers using the concept of apparent densities. Methods 2018; 144:125-133. [DOI: 10.1016/j.ymeth.2018.03.010] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2018] [Revised: 03/14/2018] [Accepted: 03/26/2018] [Indexed: 12/30/2022] Open
|
22
|
Epping R, Panne U, Falkenhagen J. Power of Ultra Performance Liquid Chromatography/Electrospray Ionization-MS Reconstructed Ion Chromatograms in the Characterization of Small Differences in Polymer Microstructure. Anal Chem 2018; 90:3467-3474. [DOI: 10.1021/acs.analchem.7b05214] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Affiliation(s)
- Ruben Epping
- Bundesanstalt für Materialforschung und−prüfung (BAM), Richard-Willstätter-Straße 11, 12489 Berlin, Germany
| | - Ulrich Panne
- Bundesanstalt für Materialforschung und−prüfung (BAM), Richard-Willstätter-Straße 11, 12489 Berlin, Germany
- Chemistry Department, Humboldt Universität zu Berlin, Brook-Taylor-Straße 2, D-12489 Berlin, Germany
| | - Jana Falkenhagen
- Bundesanstalt für Materialforschung und−prüfung (BAM), Richard-Willstätter-Straße 11, 12489 Berlin, Germany
| |
Collapse
|
23
|
Duez Q, Chirot F, Liénard R, Josse T, Choi C, Coulembier O, Dugourd P, Cornil J, Gerbaux P, De Winter J. Polymers for Traveling Wave Ion Mobility Spectrometry Calibration. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2017; 28:2483-2491. [PMID: 28762031 DOI: 10.1007/s13361-017-1762-4] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/02/2017] [Revised: 06/30/2017] [Accepted: 07/09/2017] [Indexed: 06/07/2023]
Abstract
One of the main issues when using traveling wave ion mobility spectrometry (TWIMS) for the determination of collisional cross-section (CCS) concerns the need for a robust calibration procedure built from referent ions of known CCS. Here, we implement synthetic polymer ions as CCS calibrants in positive ion mode. Based on their intrinsic polydispersities, polymers offer in a single sample the opportunity to generate, upon electrospray ionization, numerous ions covering a broad mass range and a large CCS window for different charge states at a time. In addition, the key advantage of polymer ions as CCS calibrants lies in the robustness of their gas-phase structure with respect to the instrumental conditions, making them less prone to collisional-induced unfolding (CIU) than protein ions. In this paper, we present a CCS calibration procedure using sodium cationized polylactide and polyethylene glycol, PLA and PEG, as calibrants with reference CCS determined on a home-made drift tube. Our calibration procedure is further validated by testing the polymer calibration to determine CCS of numerous different ions for which CCS are reported in the literature. Graphical Abstract ᅟ.
Collapse
Affiliation(s)
- Quentin Duez
- Organic Synthesis and Mass Spectrometry Laboratory, Interdisciplinary Center for Mass Spectrometry (CISMa), University of Mons (UMons), Place du Parc, 23, Mons, 7000, Belgium
- Laboratory for Chemistry of Novel Materials, Center of Innovation and Research in Materials and Polymers (CIRMAP), University of Mons (UMons), Place du Parc, 23, Mons, 7000, Belgium
| | - Fabien Chirot
- Université Lyon, Université Claude Bernard Lyon 1, ENS de Lyon, CNRS, Institut des Sciences Analytiques, UMR 5280, 5 rue de la Doua, F-69100, Villeurbanne, France
| | - Romain Liénard
- Organic Synthesis and Mass Spectrometry Laboratory, Interdisciplinary Center for Mass Spectrometry (CISMa), University of Mons (UMons), Place du Parc, 23, Mons, 7000, Belgium
- Laboratory of Polymeric and Composite Materials, Center of Innovation and Research in Materials and Polymers (CIRMAP), University of Mons, UMons, 23 Place du Parc, 7000, Mons, Belgium
| | - Thomas Josse
- Organic Synthesis and Mass Spectrometry Laboratory, Interdisciplinary Center for Mass Spectrometry (CISMa), University of Mons (UMons), Place du Parc, 23, Mons, 7000, Belgium
- Laboratory of Polymeric and Composite Materials, Center of Innovation and Research in Materials and Polymers (CIRMAP), University of Mons, UMons, 23 Place du Parc, 7000, Mons, Belgium
| | - ChangMin Choi
- Université Lyon, Université Claude Bernard Lyon 1, CNRS, Institut Lumière Matière, F-69622, Lyon, France
| | - Olivier Coulembier
- Laboratory of Polymeric and Composite Materials, Center of Innovation and Research in Materials and Polymers (CIRMAP), University of Mons, UMons, 23 Place du Parc, 7000, Mons, Belgium
| | - Philippe Dugourd
- Université Lyon, Université Claude Bernard Lyon 1, CNRS, Institut Lumière Matière, F-69622, Lyon, France
| | - Jérôme Cornil
- Laboratory for Chemistry of Novel Materials, Center of Innovation and Research in Materials and Polymers (CIRMAP), University of Mons (UMons), Place du Parc, 23, Mons, 7000, Belgium
| | - Pascal Gerbaux
- Organic Synthesis and Mass Spectrometry Laboratory, Interdisciplinary Center for Mass Spectrometry (CISMa), University of Mons (UMons), Place du Parc, 23, Mons, 7000, Belgium
| | - Julien De Winter
- Organic Synthesis and Mass Spectrometry Laboratory, Interdisciplinary Center for Mass Spectrometry (CISMa), University of Mons (UMons), Place du Parc, 23, Mons, 7000, Belgium.
| |
Collapse
|
24
|
Haler JRN, Far J, Aqil A, Claereboudt J, Tomczyk N, Giles K, Jérôme C, De Pauw E. Multiple Gas-Phase Conformations of a Synthetic Linear Poly(acrylamide) Polymer Observed Using Ion Mobility-Mass Spectrometry. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2017; 28:2492-2499. [PMID: 28808984 DOI: 10.1007/s13361-017-1769-x] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/30/2017] [Revised: 07/14/2017] [Accepted: 07/20/2017] [Indexed: 06/07/2023]
Abstract
Ion mobility-mass spectrometry (IM-MS) has emerged as a powerful separation and identification tool to characterize synthetic polymer mixtures and topologies (linear, cyclic, star-shaped,…). Electrospray coupled to IM-MS already revealed the coexistence of several charge state-dependent conformations for a single charge state of biomolecules with strong intramolecular interactions, even when limited resolving power IM-MS instruments were used. For synthetic polymers, the sample's polydispersity allows the observation of several chain lengths. A unique collision cross-section (CCS) trend is usually observed when increasing the degree of polymerization (DP) at constant charge state, allowing the deciphering of different polymer topologies. In this paper, we report multiple coexisting CCS trends when increasing the DP at constant charge state for linear poly(acrylamide) PAAm in the gas phase. This is similar to observations on peptides and proteins. Biomolecules show in addition population changes when collisionally heating the ions. In the case of synthetic PAAm, fragmentation occurred before reaching the energy for conformation conversion. These observations, which were made on two different IM-MS instruments (SYNAPT G2 HDMS and high resolution multi-pass cyclic T-Wave prototype from Waters), limit the use of ion mobility for synthetic polymer topology interpretations to polymers where unique CCS values are observed for each DP at constant charge state. Graphical Abstract ᅟ.
Collapse
Affiliation(s)
- Jean R N Haler
- Mass Spectrometry Laboratory, University of Liège, Quartier Agora, Allée du Six Aout 11, B-4000, Liège, Belgium.
| | - Johann Far
- Mass Spectrometry Laboratory, University of Liège, Quartier Agora, Allée du Six Aout 11, B-4000, Liège, Belgium
| | - Abdelhafid Aqil
- Center for Education and Research on Macromolecules, Department of Chemistry, University of Liège, Quartier Agora, Allée du Six Aout 13, B-4000, Liège, Belgium
| | - Jan Claereboudt
- Waters Corporation, Connexion Business Park, Brusselsesteenweg 500, 1731, Zellik, Belgium
| | - Nick Tomczyk
- Waters Corporation, Stamford Ave., Wilmslow, SK9 4AX, UK
| | - Kevin Giles
- Waters Corporation, Stamford Ave., Wilmslow, SK9 4AX, UK
| | - Christine Jérôme
- Center for Education and Research on Macromolecules, Department of Chemistry, University of Liège, Quartier Agora, Allée du Six Aout 13, B-4000, Liège, Belgium
| | - Edwin De Pauw
- Mass Spectrometry Laboratory, University of Liège, Quartier Agora, Allée du Six Aout 11, B-4000, Liège, Belgium
| |
Collapse
|
25
|
He Q, Mao J, Wesdemiotis C, Quirk RP, Foster MD. Synthesis and Isomeric Characterization of Well-Defined 8-Shaped Polystyrene Using Anionic Polymerization, Silicon Chloride Linking Chemistry, and Metathesis Ring Closure. Macromolecules 2017. [DOI: 10.1021/acs.macromol.7b01121] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Affiliation(s)
- Qiming He
- Department
of Polymer Science and ‡Department of Chemistry, The University of Akron, Akron, Ohio 44325, United States
| | - Jialin Mao
- Department
of Polymer Science and ‡Department of Chemistry, The University of Akron, Akron, Ohio 44325, United States
| | - Chrys Wesdemiotis
- Department
of Polymer Science and ‡Department of Chemistry, The University of Akron, Akron, Ohio 44325, United States
| | - Roderic P. Quirk
- Department
of Polymer Science and ‡Department of Chemistry, The University of Akron, Akron, Ohio 44325, United States
| | - Mark D. Foster
- Department
of Polymer Science and ‡Department of Chemistry, The University of Akron, Akron, Ohio 44325, United States
| |
Collapse
|
26
|
Duez Q, Josse T, Lemaur V, Chirot F, Choi CM, Dubois P, Dugourd P, Cornil J, Gerbaux P, De Winter J. Correlation between the shape of the ion mobility signals and the stepwise folding process of polylactide ions. JOURNAL OF MASS SPECTROMETRY : JMS 2017; 52:133-138. [PMID: 28112477 DOI: 10.1002/jms.3915] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/14/2016] [Revised: 01/18/2017] [Accepted: 01/19/2017] [Indexed: 06/06/2023]
Abstract
In the field of polymer characterization, the use of ion mobility mass spectrometry (IMMS) remains mainly devoted to the temporal separation of cationized oligomers according to their charge states, molecular masses and macromolecular architectures in order to probe the presence of different structures. When analyzing multiply charged polymer ions by IMMS, the most striking feature is the observation of breaking points in the evolution of the average collision cross sections with the number of monomer units. Those breaking points are associated to the folding of the polymer chain around the cationizing agents. Here, we scrutinize the shape of the arrival time distribution (ATD) of polylactide ions and associate the broadening as well as the loss of symmetry of the ATD signals to the coexistence of different populations of ions attributed to the transition from opened to folded stable structures. The observation of distinct distributions reveals the absence of folded/extended structure interconversion on the ion mobility time scale (1-10 ms) and then on the lifetime of ions within the mass spectrometer at room temperature. In order to obtain information on the possible interconversion between the different observed populations upon ion activation, we performed IM-IM-MS experiments (tandem ion mobility measurements). To do so, mobility-selected ions were activated by collisions before a second mobility measurement. Interestingly, the conversion by collisional activation from a globular structure into a (partially) extended structure, i.e. the gas phase unfolding of the ions, was not observed in the energetic regime available with the used experimental setup. The absence of folded/extended interconversion, even upon collisional activation, points to the fact that the polylactide ions are 'frozen' in their specific 3D structure during the desolvation/ionization electrospray processes. Copyright © 2017 John Wiley & Sons, Ltd.
Collapse
Affiliation(s)
- Q Duez
- Organic Synthesis and Mass Spectrometry Laboratory, Interdisciplinary Center for Mass Spectrometry (CISMa), University of Mons, UMons, 23 Place du Parc, 7000, Mons, Belgium
- Laboratory for Chemistry of Novel Materials, Center of Innovation and Research in Materials and Polymers (CIRMAP), University of Mons, UMons, 23 Place du Parc, 7000, Mons, Belgium
| | - T Josse
- Organic Synthesis and Mass Spectrometry Laboratory, Interdisciplinary Center for Mass Spectrometry (CISMa), University of Mons, UMons, 23 Place du Parc, 7000, Mons, Belgium
- Laboratory of Polymeric and Composite Materials, Center of Innovation and Research in Materials and Polymers (CIRMAP), University of Mons, UMons, 23 Place du Parc, 7000, Mons, Belgium
| | - V Lemaur
- Laboratory for Chemistry of Novel Materials, Center of Innovation and Research in Materials and Polymers (CIRMAP), University of Mons, UMons, 23 Place du Parc, 7000, Mons, Belgium
| | - F Chirot
- Univ Lyon, Université Claude Bernard Lyon 1, Ens de Lyon, CNRS, Institut des Sciences Analytiques, UMR 5280, 5 rue de la Doua, F-69100, Villeurbanne, France
| | - C M Choi
- Univ Lyon, Université Claude Bernard Lyon 1, CNRS, Institut Lumière Matière, F-69622, Lyon, France
| | - P Dubois
- Laboratory of Polymeric and Composite Materials, Center of Innovation and Research in Materials and Polymers (CIRMAP), University of Mons, UMons, 23 Place du Parc, 7000, Mons, Belgium
| | - P Dugourd
- Univ Lyon, Université Claude Bernard Lyon 1, CNRS, Institut Lumière Matière, F-69622, Lyon, France
| | - J Cornil
- Laboratory for Chemistry of Novel Materials, Center of Innovation and Research in Materials and Polymers (CIRMAP), University of Mons, UMons, 23 Place du Parc, 7000, Mons, Belgium
| | - P Gerbaux
- Organic Synthesis and Mass Spectrometry Laboratory, Interdisciplinary Center for Mass Spectrometry (CISMa), University of Mons, UMons, 23 Place du Parc, 7000, Mons, Belgium
| | - J De Winter
- Organic Synthesis and Mass Spectrometry Laboratory, Interdisciplinary Center for Mass Spectrometry (CISMa), University of Mons, UMons, 23 Place du Parc, 7000, Mons, Belgium
| |
Collapse
|
27
|
Wesdemiotis C. Multidimensional Mass Spectrometry of Synthetic Polymers and Advanced Materials. Angew Chem Int Ed Engl 2017; 56:1452-1464. [PMID: 27712048 DOI: 10.1002/anie.201607003] [Citation(s) in RCA: 71] [Impact Index Per Article: 10.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2016] [Revised: 10/02/2016] [Indexed: 01/06/2023]
Abstract
Multidimensional mass spectrometry interfaces a suitable ionization technique and mass analysis (MS) with fragmentation by tandem mass spectrometry (MS2 ) and an orthogonal online separation method. Separation choices include liquid chromatography (LC) and ion-mobility spectrometry (IMS), in which separation takes place pre-ionization in the solution state or post-ionization in the gas phase, respectively. The MS step provides elemental composition information, while MS2 exploits differences in the bond stabilities of a polymer, yielding connectivity and sequence information. LC conditions can be tuned to separate by polarity, end-group functionality, or hydrodynamic volume, whereas IMS adds selectivity by macromolecular shape and architecture. This Minireview discusses how selected combinations of the MS, MS2 , LC, and IMS dimensions can be applied, together with the appropriate ionization method, to determine the constituents, structures, end groups, sequences, and architectures of a wide variety of homo- and copolymeric materials, including multicomponent blends, supramolecular assemblies, novel hybrid materials, and large cross-linked or nonionizable polymers.
Collapse
Affiliation(s)
- Chrys Wesdemiotis
- Department of Chemistry, The University of Akron, Akron, OH, 44325, USA
| |
Collapse
|
28
|
Wesdemiotis C. Mehrdimensionale Massenspektrometrie von synthetischen Polymeren und modernen Materialien. Angew Chem Int Ed Engl 2017. [DOI: 10.1002/ange.201607003] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Affiliation(s)
- Chrys Wesdemiotis
- Department of Chemistry; The University of Akron; Akron OH 44325 USA
| |
Collapse
|
29
|
Shi C, Gerişlioğlu S, Wesdemiotis C. Ultrahigh Performance Liquid Chromatography Interfaced with Mass Spectrometry and Orthogonal Ion Mobility Separation for the Microstructure Characterization of Amphiphilic Block Copolymers. Chromatographia 2016. [DOI: 10.1007/s10337-016-3077-1] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
|