1
|
Li Z, Sun L, Tan Y, Wang Z, Yang X, Huang T, Li J, Zhang Y, Guan B. Flexible Optoelectronic Hybrid Microfiber Long-period Grating Multimodal Sensor. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2025; 12:e2501352. [PMID: 40056056 PMCID: PMC12061331 DOI: 10.1002/advs.202501352] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/21/2025] [Revised: 02/23/2025] [Indexed: 05/10/2025]
Abstract
Flexible wearable biosensors have emerged as a promising tool for tracking dynamic glycemic profiles of human body in diabetes management. However, it remains a challenge to balance the shrunken device space and multiple redundant sensing arrays for further advancement in miniaturization of multimodal sensors. Herein, this work proposes an entirely new optoelectronic hybrid multimodal optical fiber sensor which is composed of laser patterning of polydimethylsiloxane (PDMS) to form laser-induced graphene (LIG) as the interdigital electrodes, and a long period grating (LPG) prepared from an optical microfiber encapsulated into the PDMS modulated by periodical structure of LIG electrodes. This operation can simultaneously integrate two heterogeneous sensing mechanisms, optical and electrical, into a single sensor in a compact manner. Combining the LIG electrode with conductive hydrogel, a flexible glucose biosensor based on electrical mechanism is constructed by loading glucose oxidase into the hydrogel. Meanwhile, the microfiber LPG can also be served as a spectroscopically available sensor for biomechanical monitoring. Optical and electrical sensors can work simultaneously but independently of each other, particularly in the scene of wound healing for rat model and movement for human exercise. This platform represents a pivotal step toward multifunctional sensors that enable measurements of biomechanical information and glucose.
Collapse
Affiliation(s)
- Zhenru Li
- Guangdong Provincial Key Laboratory of Optical Fiber Sensing and CommunicationsInstitute of Photonics TechnologyCollege of Physics & Optoelectronic EngineeringJinan UniversityGuangzhou510632China
| | - Li‐Peng Sun
- Guangdong Provincial Key Laboratory of Optical Fiber Sensing and CommunicationsInstitute of Photonics TechnologyCollege of Physics & Optoelectronic EngineeringJinan UniversityGuangzhou510632China
| | - Yanzhen Tan
- School of Electronic Engineering and IntelligentizationDongguan University of TechnologyDongguan523808China
| | - Zhiwei Wang
- Guangdong Provincial Key Laboratory of Optical Fiber Sensing and CommunicationsInstitute of Photonics TechnologyCollege of Physics & Optoelectronic EngineeringJinan UniversityGuangzhou510632China
| | - Xiao Yang
- Guangdong Provincial Key Laboratory of Optical Fiber Sensing and CommunicationsInstitute of Photonics TechnologyCollege of Physics & Optoelectronic EngineeringJinan UniversityGuangzhou510632China
| | - Tiansheng Huang
- Guangdong Provincial Key Laboratory of Optical Fiber Sensing and CommunicationsInstitute of Photonics TechnologyCollege of Physics & Optoelectronic EngineeringJinan UniversityGuangzhou510632China
| | - Jie Li
- Guangdong Provincial Key Laboratory of Optical Fiber Sensing and CommunicationsInstitute of Photonics TechnologyCollege of Physics & Optoelectronic EngineeringJinan UniversityGuangzhou510632China
| | - Yi Zhang
- Key Laboratory of Biomaterials of Guangdong Higher Education InstitutesDepartment of Biomedical EngineeringJinan UniversityGuangzhou510632China
| | - Bai‐Ou Guan
- Guangdong Provincial Key Laboratory of Optical Fiber Sensing and CommunicationsInstitute of Photonics TechnologyCollege of Physics & Optoelectronic EngineeringJinan UniversityGuangzhou510632China
| |
Collapse
|
2
|
Ordoño J, Islam M, Lantada AD, Echeverry-Rendón M, Wang DY. Evaluation of laser-induced graphene for skeletal muscle tissue engineering applications. Biomater Sci 2025. [PMID: 40304552 DOI: 10.1039/d5bm00174a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/02/2025]
Abstract
This study explores the potential of laser-induced graphene (LIG) as a conductive, biocompatible material for musculoskeletal tissue engineering applications. Using laser irradiation, polyimide (PI) substrates were transformed into highly graphitic, porous LIG with a distinct fibril morphology and surface topography. Characterization analyses, including Raman spectroscopy and X-ray diffraction (XRD), confirmed the graphitic nature of LIG, while electrical conductivity measurements indicated a value of 5.8 ± 0.2 S cm-1, with the surface demonstrating hydrophobicity (contact angle of 95.3° ± 1.9°). Biocompatibility tests using the C2C12 myoblast cell line showed high cell viability and alignment along the laser-induced pattern of LIG, an attribute essential for muscle tissue engineering. Cells cultured on LIG demonstrated progressive proliferation and expression of myogenic markers under reduced serum conditions, indicating the ability of LIG to support myogenic differentiation. These findings highlight LIG as a promising biomaterial that combines bioelectrical functionality with structural support, offering new avenues for developing advanced microsystems interacting with cells, leading to novel tissue engineering solutions for muscle repair and regeneration.
Collapse
Affiliation(s)
- Jesús Ordoño
- IMDEA Materials Institute, Calle Eric Kandel, 2, 28906 Getafe, Madrid, Spain.
| | - Monsur Islam
- IMDEA Materials Institute, Calle Eric Kandel, 2, 28906 Getafe, Madrid, Spain.
| | - Andrés Díaz Lantada
- Department of Mechanical Engineering, Universidad Politécnica de Madrid, José Gutierréz Abascal, 2, Madrid, 28006, Spain
| | | | - De-Yi Wang
- IMDEA Materials Institute, Calle Eric Kandel, 2, 28906 Getafe, Madrid, Spain.
| |
Collapse
|
3
|
Kang L, Jiang J, Liu S, Ai J, Hong J, Tang C, Jun SC, Yamauchi Y, Zhang J. In Situ Spatially Confined Silver Nanoparticles in 3D Laser-Induced Graphene Architecture for All-in-One Planar Supercapacitor-Glucose Sensor System. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2025:e2412044. [PMID: 40195885 DOI: 10.1002/smll.202412044] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/11/2024] [Revised: 03/05/2025] [Indexed: 04/09/2025]
Abstract
Self-powered integrated systems that leverage micro-supercapacitors as power sources for sensors are vital for portable and wearable electronics; however, they often encounter compatibility issues arising from bifunctional active materials that enable high energy storage capacity and sensing performance. Herein, a spatial confinement approach is proposed for designing in situ-encased silver nanoparticles within a 3D porous laser-induced graphene framework (LIG/Ag), which serves as a bifunctional active material for all-in-one supercapacitor-sensor systems. Such engineered LIG/Ag features ample pseudocapacitive active sites, high electrical conductivity, and fast ion diffusion channels, which favor high reaction kinetics and electrode material utilization, significantly improving its electrochemical reactivity. Flexible symmetric supercapacitors (FCSs) assembled with an optimized LIG/Ag achieve a high energy density of 0.27 µWh cm-2, with a capacitance retention of 92.6% after 10 000 cycles, as well as good mechanical stability. Furthermore, a flexible three-electrode (FTE) assembled with the optimized LIG/Ag exhibits a glucose detection sensitivity of 405.24 µA mM-1 cm-2 and a fast response time of less than 1 s. As a proof-of-concept, a flexible, planar, self-powered glucose detection system with a LIG/Ag hybrid serving as a bifunctional active material delivers favorable capacitive properties and high glucose sensitivity, demonstrating its feasibility for glucose concentration monitoring.
Collapse
Affiliation(s)
- Ling Kang
- Shanghai Key Laboratory of Multidimensional Information Processing, East China Normal University, 500 Dongchuan Road, Shanghai, 200241, China
- School of Mechanical Engineering, Yonsei University, Seoul, 120-749, South Korea
| | - Jiaming Jiang
- Shanghai Key Laboratory of Multidimensional Information Processing, East China Normal University, 500 Dongchuan Road, Shanghai, 200241, China
| | - Shude Liu
- College of Textiles, Donghua University, Shanghai, 201620, China
- Department of Materials Process Engineering, Graduate School of Engineering, Nagoya University, Nagoya, 464-8603, Japan
| | - Jin Ai
- Shanghai Key Laboratory of Multidimensional Information Processing, East China Normal University, 500 Dongchuan Road, Shanghai, 200241, China
| | - Jongwoo Hong
- School of Mechanical Engineering, Yonsei University, Seoul, 120-749, South Korea
| | - Chenghuan Tang
- Shanghai Key Laboratory of Multidimensional Information Processing, East China Normal University, 500 Dongchuan Road, Shanghai, 200241, China
| | - Seong Chan Jun
- School of Mechanical Engineering, Yonsei University, Seoul, 120-749, South Korea
| | - Yusuke Yamauchi
- Department of Materials Process Engineering, Graduate School of Engineering, Nagoya University, Nagoya, 464-8603, Japan
- Australian Institute for Bioengineering and Nanotechnology, The University of Queensland, Brisbane, QLD, 4072, Australia
| | - Jian Zhang
- Shanghai Key Laboratory of Multidimensional Information Processing, East China Normal University, 500 Dongchuan Road, Shanghai, 200241, China
| |
Collapse
|
4
|
Dallinger A, Camerini R, Parlanti P, Gemmi M, Sankaran ST, Galliani M, Kunert B, Giorgi R, Greco F. Laser-Induced Graphene from Commercial Inks and Dyes. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2025; 12:e2412167. [PMID: 39951342 PMCID: PMC11984850 DOI: 10.1002/advs.202412167] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/30/2024] [Revised: 01/13/2025] [Indexed: 02/16/2025]
Abstract
Laser-induced graphene (LIG) has been so far obtained from polymer precursors and proposed for numerous applications, including various types of sensors and energy storage solutions. This study examines a radically different class of new precursors for LIG, distinct from polymers: inks and dyes. The identification of specific organic dyes present in commercial markers demonstrates that the aromatic structure, in conjunction with high thermal stability (residual weight > 20% at 800°C), are key factors for laser-induced pyrolysis. Eosin Y is identified as an excellent LIG precursor, comparable with well-known polyimide. The unique properties of dyes allow for dispersion in various media, such as acrylic binder. A dye concentration of 0.75 mol L-1 in acrylic binder results in a conductivity of 34 ± 20 S cm-1 for LIG. The composition and microstructure of LIG from dyes are thoroughly characterized, revealing peculiar features. A versatile "Paint & Scribe" methodology is introduced, enabling to integrate LIG tracks onto any wettable surface, and in particular onto printed and flexible electronics. A process for obtaining freestanding and transferrable LIG is demonstrated by dissolving acrylic paint in acetone and floating LIG in water. This advancement offers novel avenues for diverse applications that necessitate a transfer process of LIG.
Collapse
Affiliation(s)
- Alexander Dallinger
- Institute of Solid State PhysicsNAWI GrazGraz University of TechnologyGraz8010Austria
| | - Rachel Camerini
- Center for Colloid and Surface Science – CSGI and Department of ChemistryUniversity of FlorenceVia della Lastruccia 3Sesto Fiorentino50019Italy
| | - Paola Parlanti
- Center for Materials InterfacesElectron CrystallographyIstituto Italiano di TecnologiaViale R. Piaggio 34Pontedera56025Italy
| | - Mauro Gemmi
- Center for Materials InterfacesElectron CrystallographyIstituto Italiano di TecnologiaViale R. Piaggio 34Pontedera56025Italy
| | - Sreenadh Thaikkattu Sankaran
- The Biorobotics Institute and Dept. of Excellence in Robotics & AIScuola Superiore Sant'AnnaViale R. Piaggio 34Pontedera56025Italy
| | - Marina Galliani
- The Biorobotics Institute and Dept. of Excellence in Robotics & AIScuola Superiore Sant'AnnaViale R. Piaggio 34Pontedera56025Italy
| | - Birgit Kunert
- Institute of Solid State PhysicsNAWI GrazGraz University of TechnologyGraz8010Austria
| | - Rodorico Giorgi
- Center for Colloid and Surface Science – CSGI and Department of ChemistryUniversity of FlorenceVia della Lastruccia 3Sesto Fiorentino50019Italy
| | - Francesco Greco
- Institute of Solid State PhysicsNAWI GrazGraz University of TechnologyGraz8010Austria
- The Biorobotics Institute and Dept. of Excellence in Robotics & AIScuola Superiore Sant'AnnaViale R. Piaggio 34Pontedera56025Italy
- Interdisciplinary Center on Sustainability and ClimateScuola Superiore Sant'AnnaPiazza Martiri della Libertà 33Pisa56127Italy
| |
Collapse
|
5
|
Thang TQ, Kim J. Laser Irradiation and Property Correlation in Double-Lasing Processes on Laser-Induced Graphene Electrodes. NANOMATERIALS (BASEL, SWITZERLAND) 2025; 15:333. [PMID: 40072136 PMCID: PMC11901533 DOI: 10.3390/nano15050333] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/10/2025] [Accepted: 02/12/2025] [Indexed: 03/14/2025]
Abstract
The fabrication of laser-induced graphene (LIG) electrodes by direct laser writing techniques has received considerable attention due to its simplicity, versatility, and cost-effectiveness for electrochemical applications in both sensing and energy storage. In general, a single-lasing irradiation process is used to prepare LIG electrodes. However, the intrinsic features of LIG can be further improved by taking advantage of additional lasing processes, even without any chemical treatments. In this work, we investigated the potential enhancement of LIG's electrochemical performance through a double-lasing irradiation process. This process does not require any chemical modification of the LIG to improve its electrochemical performance. Importantly, we revealed the correlation between laser irradiation and the properties of LIG electrodes prepared through the lasing process. We evaluated the characteristics of LIG electrodes prepared by the single-lasing and double-lasing irradiation regarding their microstructures and electrochemical features, including the sheet resistance (RS), specific areal capacitance (CA), peak-to-peak separation (ΔEP), and peak current. The double-lasing LIG exhibited improved electrochemical properties, especially low RS and ΔEP values. This improvement results from a higher degree of graphitization, making them advantageous for developing electrochemical sensors. This was demonstrated by the improved electrochemical sensing of H2O2 using the double-lasing LIG.
Collapse
Affiliation(s)
- Tran Quoc Thang
- Department of Chemistry, Research Institute for Basic Sciences, Kyung Hee University, Seoul 02447, Republic of Korea;
| | - Joohoon Kim
- Department of Chemistry, Research Institute for Basic Sciences, Kyung Hee University, Seoul 02447, Republic of Korea;
- KHU-KIST Department of Converging Science and Technology, Kyung Hee University, Seoul 02447, Republic of Korea
| |
Collapse
|
6
|
Vardhan V, Biswas S, Ghosh S, Tsetseris L, Hellebust S, Echresh A, Georgiev YM, Holmes JD. Nitrogen Dioxide Detection with Ambipolar Silicon Nanowire Transistor Sensors. ACS APPLIED MATERIALS & INTERFACES 2025; 17:9539-9553. [PMID: 39889144 PMCID: PMC11826891 DOI: 10.1021/acsami.4c18322] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/23/2024] [Revised: 01/20/2025] [Accepted: 01/20/2025] [Indexed: 02/02/2025]
Abstract
Si nanowire transistors are ideal for the sensitive detection of atmospheric species due to their enhanced sensitivity to changes in the electrostatic potential at the channel surface. In this study, we present unique ambipolar Si junctionless nanowire transistors (Si-JNTs) that incorporate both n- and p-type conduction within a single device. These transistors enable scalable detection of nitrogen dioxide (NO2), a critical atmospheric oxidative pollutant, across a broad concentration range, from high levels (25-50 ppm) to low levels (250 ppb-2 ppm). Acting as an electron acceptor, NO2 generates holes and functions as a pseudodopant for Si-JNTs, altering the conductance and other device parameters. Consequently, ambipolar Si-JNTs exhibit a dual response at room temperature, reacting on both p- and n-conduction channels when exposed to gaseous NO2, thereby offering a larger parameter space compared to a unipolar device. Key characteristics of the Si-JNTs, including on-current (Ion), threshold voltage (Vth) and mobility (μ), were observed to dynamically change on both the p- and n-channels when exposed to NO2. The p-conduction channel showed superior performance across all parameters when compared to the device's n-channel. For example, within the NO2 concentration range of 250 ppb to 2 ppm, the p-channel achieved a responsivity of 37%, significantly surpassing the n-channel's 12.5%. Additionally, the simultaneous evolution of multiple parameters in this dual response space enhances the selectivity of Si-JNTs toward NO2 and improves their ability to distinguish between different pollutant gases, such as NO2, ammonia, sulfur dioxide and methane.
Collapse
Affiliation(s)
- Vaishali Vardhan
- School
of Chemistry, University College Cork, Cork T12 YN60, Ireland
- AMBER
Centre, Environmental Research Institute, University College Cork, Cork T23 XE10, Ireland
| | - Subhajit Biswas
- School
of Chemistry, University College Cork, Cork T12 YN60, Ireland
- AMBER
Centre, Environmental Research Institute, University College Cork, Cork T23 XE10, Ireland
| | - Sayantan Ghosh
- Institute
of Ion Beam Physics and Materials Research, Helmholtz-Zentrum Dresden Rossendorf, 01328 Dresden, Germany
- Technische
Universität Dresden, Dresden 01069, Germany
| | - Leonidas Tsetseris
- Department
of Physics, School of Applied Mathematical and Physical Sciences, National Technical University of Athens, Athens 15780, Greece
| | - S. Hellebust
- School
of Chemistry, University College Cork, Cork T12 YN60, Ireland
- AMBER
Centre, Environmental Research Institute, University College Cork, Cork T23 XE10, Ireland
| | - Ahmad Echresh
- Institute
of Ion Beam Physics and Materials Research, Helmholtz-Zentrum Dresden Rossendorf, 01328 Dresden, Germany
| | - Yordan M. Georgiev
- Institute
of Ion Beam Physics and Materials Research, Helmholtz-Zentrum Dresden Rossendorf, 01328 Dresden, Germany
- Institute
of Electronics at the Bulgarian Academy of Sciences, 72, Tsarigradsko Chaussee Blvd., Sofia 1784, Bulgaria
| | - Justin D. Holmes
- School
of Chemistry, University College Cork, Cork T12 YN60, Ireland
- AMBER
Centre, Environmental Research Institute, University College Cork, Cork T23 XE10, Ireland
| |
Collapse
|
7
|
Sevene D, Matias TA, Araújo DAG, Inoque NIG, Nakamura M, Paixão TR, Muñoz RAA. Laser-Induced Graphene for Electrochemical Sensing of Antioxidants in Biodiesel. ACS OMEGA 2025; 10:368-377. [PMID: 39829466 PMCID: PMC11740131 DOI: 10.1021/acsomega.4c06339] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/09/2024] [Revised: 10/16/2024] [Accepted: 11/07/2024] [Indexed: 01/22/2025]
Abstract
Synthetic antioxidants are often introduced to biodiesel to increase its oxidative stability, and tert-butyl hydroquinone (TBHQ) has been selected due to its high efficiency for this purpose. The monitoring of antioxidants in biodiesel therefore provides information on the oxidative stability of biodiesels. Herein, a laser-induced graphene (LIG) electrode is introduced as a new sensor for detecting tert-butyl hydroquinone (TBHQ) in biodiesel samples. An infrared CO2 laser was applied for LIG formation from the pyrolysis of polyimide (Kapton). Based on the voltammetric profile of a reversible redox probe, the fabrication of LIG electrodes was set using 1.0 W power and 40 mm s-1 speed, which presented an electroactive area of 0.26 cm2 (higher than the geometric area of 0.196 cm2). Importantly, lower engraving speed resulted in higher electroactive area, probably due to a more efficient graphene formation. Scanning-electron microscopy and Raman spectroscopy confirmed the creation of porous graphene induced by laser. The sensing platform enabled the differential-pulse voltammetric determination of TBHQ from 5 and 450 μmol L-1. The values of detection limit (LOD) of 2 μmol L-1 and RSD (relative standard deviation) of 2.5% (n = 10, 10 μmol L-1 of TBHQ) were obtained. The analysis of spiked biodiesel samples revealed recoveries from 88 to 106%. Also, the method provides a satisfactory selectivity, as it is free of interference from metallic ions (Fe3+, Mn2+, Cr2+, Zn2+, Pb2+, and Cu2+) commonly presented in the biofuel. These results show that LIG electrodes can be a new electroanalytical tool for detecting and quantifying TBHQ in biodiesel.
Collapse
Affiliation(s)
- Daniel
R. Sevene
- Institute
of Chemistry, UFU, Federal University of
Uberlândia, Uberlândia, Minas Gerais 38400-902, Brazil
| | - Tiago A. Matias
- Department
of Chemistry, UFES, Federal University of
Espírito Santo, Vitória, Espírito Santo, 29075-910, Brazil
| | - Diele A. G. Araújo
- Institute
of Chemistry, USP, University of São
Paulo, São
Paulo, São Paulo 05508-220, Brazil
| | - Nélio I. G. Inoque
- Institute
of Chemistry, UFU, Federal University of
Uberlândia, Uberlândia, Minas Gerais 38400-902, Brazil
| | - Marcelo Nakamura
- Institute
of Chemistry, USP, University of São
Paulo, São
Paulo, São Paulo 05508-220, Brazil
| | - Thiago R.L.C. Paixão
- Institute
of Chemistry, USP, University of São
Paulo, São
Paulo, São Paulo 05508-220, Brazil
| | - Rodrigo A. A. Muñoz
- Institute
of Chemistry, UFU, Federal University of
Uberlândia, Uberlândia, Minas Gerais 38400-902, Brazil
| |
Collapse
|
8
|
Yu W, Chen X, Li X, Wei Z, Tang J, Zhang M. Laser-induced multi-doped graphene extended-gate field-effect transistor sensor for enhanced detection of cystatin C. Talanta 2025; 282:127039. [PMID: 39406078 DOI: 10.1016/j.talanta.2024.127039] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2024] [Revised: 09/21/2024] [Accepted: 10/10/2024] [Indexed: 11/20/2024]
Abstract
In this study, we amplified the capabilities of laser-induced graphene (LIG) by developing a multi-doped LIG extended-gated field-effect transistor (EG-FET) sensor. This sensor integrates a multi-doped LIG EG electrode array as a disposable sensing component with a standard MOSFET for reusable transduction. The multi-doped LIG was synthesized using a dual-approach: initially, by using a MnCl2-doped polyimide (MnCl2-PI) film through precursor compounding, and subsequently, by employing a CO2 laser to respectively in situ generate MnO2 nanoparticles and gold nanoparticles (Au NPs) via direct laser conversion. By incorporating the resultant multi-doped LIG (Au NPs/MnO2/LIG) as the EG electrode, we boosted its electrical efficiency and provided ideal sites for the papain immobilization. This facilitated the selective binding of protein complexes with cystatin C (Cys C), allowing for precise measurement. Notably, the sensor exhibited a robust linear correlation across a concentration range from 50 ag/μL to 0.25 ng/μL and achieved a detection limit of 50 ag/μL. These advancements not only address traditional limitations of LIG applications but also highlight the potential of LIG-based EG-FET portable devices for accurate and early screening of chronic kidney disease (CKD).
Collapse
Affiliation(s)
- Wenbang Yu
- Jinhua University of Vocational Technology, Jinhua, 321017, China.
| | - Xiaofen Chen
- School of Chemistry and Molecular Engineering, Shanghai Key Laboratory for Urban Ecological Processes and Eco-Restoration, East China Normal University, 500 Dongchuan Road, Shanghai, 200241, China
| | - Xinjie Li
- School of Chemistry and Molecular Engineering, Shanghai Key Laboratory for Urban Ecological Processes and Eco-Restoration, East China Normal University, 500 Dongchuan Road, Shanghai, 200241, China
| | - Zihan Wei
- Shanghai Rongxiang Biotechnology Co., Ltd, Shanghai, 201100, China
| | - Jing Tang
- The Obstetrics & Gynecology Hospital of Fudan University, 419 Fangxie Road, Shanghai, 200011, China.
| | - Min Zhang
- School of Chemistry and Molecular Engineering, Shanghai Key Laboratory for Urban Ecological Processes and Eco-Restoration, East China Normal University, 500 Dongchuan Road, Shanghai, 200241, China.
| |
Collapse
|
9
|
Santos-Ceballos JC, Salehnia F, Güell F, Romero A, Vilanova X, Llobet E. Room-Temperature Ammonia Sensing Using Polyaniline-Coated Laser-Induced Graphene. SENSORS (BASEL, SWITZERLAND) 2024; 24:7832. [PMID: 39686369 DOI: 10.3390/s24237832] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/11/2024] [Revised: 12/03/2024] [Accepted: 12/06/2024] [Indexed: 12/18/2024]
Abstract
The reliable detection of ammonia at room temperature is crucial for not only maintaining environmental safety but also for reducing the risks of hazardous pollutants. In this study, the electrochemical modification of laser-induced graphene (LIG) with polyaniline (PANI) led to the development of a chemo-resistive nanocomposite (PANI@LIG) for detecting ammonia levels at room temperature. The composite is characterized by field emission scanning electron microscopy, Fourier transforms infrared, and Raman and X-ray photoelectron spectroscopy. This work marks the first utilization of PANI@LIG for gas sensing and introduces a simple but effective approach for fabricating low-cost wearable gas sensors with high sensitivity and flexibility.
Collapse
Affiliation(s)
- José Carlos Santos-Ceballos
- MINOS, School of Engineering, Universitat Rovira i Virgili, Avda. Països Catalans 26, 43007 Tarragona, Spain
- IU-RESCAT, Research Institute in Sustainability, Climatic Change and Energy Transition, Universitat Rovira i Virgili, Joanot Martorell 15, 43480 Vila-seca, Spain
- TecnATox-Centre for Environmental, Food and Toxicological Technology, Universitat Rovira i Virgili, Avda. Països Catalans 26, 43007 Tarragona, Spain
| | - Foad Salehnia
- MINOS, School of Engineering, Universitat Rovira i Virgili, Avda. Països Catalans 26, 43007 Tarragona, Spain
- IU-RESCAT, Research Institute in Sustainability, Climatic Change and Energy Transition, Universitat Rovira i Virgili, Joanot Martorell 15, 43480 Vila-seca, Spain
- TecnATox-Centre for Environmental, Food and Toxicological Technology, Universitat Rovira i Virgili, Avda. Països Catalans 26, 43007 Tarragona, Spain
| | - Frank Güell
- MINOS, School of Engineering, Universitat Rovira i Virgili, Avda. Països Catalans 26, 43007 Tarragona, Spain
- ENFOCAT, Facultat de Física, Universitat de Barcelona, C/Martí I Franquès 1, 08028 Barcelona, Spain
| | - Alfonso Romero
- MINOS, School of Engineering, Universitat Rovira i Virgili, Avda. Països Catalans 26, 43007 Tarragona, Spain
- IU-RESCAT, Research Institute in Sustainability, Climatic Change and Energy Transition, Universitat Rovira i Virgili, Joanot Martorell 15, 43480 Vila-seca, Spain
- TecnATox-Centre for Environmental, Food and Toxicological Technology, Universitat Rovira i Virgili, Avda. Països Catalans 26, 43007 Tarragona, Spain
| | - Xavier Vilanova
- MINOS, School of Engineering, Universitat Rovira i Virgili, Avda. Països Catalans 26, 43007 Tarragona, Spain
- IU-RESCAT, Research Institute in Sustainability, Climatic Change and Energy Transition, Universitat Rovira i Virgili, Joanot Martorell 15, 43480 Vila-seca, Spain
- TecnATox-Centre for Environmental, Food and Toxicological Technology, Universitat Rovira i Virgili, Avda. Països Catalans 26, 43007 Tarragona, Spain
| | - Eduard Llobet
- MINOS, School of Engineering, Universitat Rovira i Virgili, Avda. Països Catalans 26, 43007 Tarragona, Spain
- IU-RESCAT, Research Institute in Sustainability, Climatic Change and Energy Transition, Universitat Rovira i Virgili, Joanot Martorell 15, 43480 Vila-seca, Spain
- TecnATox-Centre for Environmental, Food and Toxicological Technology, Universitat Rovira i Virgili, Avda. Països Catalans 26, 43007 Tarragona, Spain
| |
Collapse
|
10
|
Sankaran ST, Dallinger A, Bressi AC, Marino A, Ciofani G, Szkudlarek A, Bilovol V, Sokolowski K, Kunert B, Hampel HK, Bernal HG, Greco F. From Corn Starch to Nanostructured Magnetic Laser-Induced Graphene Nanocomposite. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2024; 20:e2405252. [PMID: 39420870 DOI: 10.1002/smll.202405252] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/26/2024] [Revised: 10/02/2024] [Indexed: 10/19/2024]
Abstract
Laser-Induced Graphene (LIG) is a 3D, conductive, porous material with a high surface area, produced by laser irradiation of synthetic polymers with high thermal stability. Recently, the focus has shifted toward sustainable bioderived and biodegradable precursors, such as lignocellulosic materials. Despite starch being an abundant and cost-effective biopolymer, direct laser scribing on starch-derived precursors has not yet been explored. This study demonstrates that corn starch bioplastic (SP) can be converted into LIG through iron-catalyzed laser-induced pyrolysis, using Fe(NO₃)₃ as an additive. The impact of iron additive concentration on LIG formation and on its properties is investigated, with only certain concentrations yielding reliable and reproducible results. The investigation of LIG's crystal structure reveals magnetic and non-magnetic iron phases: γ-Fe₂O₃, Fe₃C, and Fe(C). The LIG nanocomposite exhibits soft magnetic properties, with a coercive field of Hc ≈ 200 Oe and a saturation magnetization of Ms ≈ 67 emu g⁻¹. The SP substrate degrades almost entirely in soil within 12 days and is unaffected by the addition of Fe(NO₃)₃, allowing for material compostability in line with circular economy principles. Consequently, SP stands out as a promising "green" precursor for magnetic LIG, paving the way for sustainable applications in environmental remediation.
Collapse
Affiliation(s)
- Sreenadh Thaikkattu Sankaran
- The Biorobotics Institute, Scuola Superiore Sant'Anna, Viale Rinaldo Piaggio 34, Pontedera, 56025, Italy
- Department of Excellence in Robotics & AI, Scuola Superiore Sant'Anna, Piazza Martiri della Libertà 33, Pisa, 56127, Italy
| | - Alexander Dallinger
- Institute of Solid State Physics, NAWI Graz, Graz University of Technology, Petersgasse 16, Graz, 8010, Austria
| | - Anna Chiara Bressi
- The Biorobotics Institute, Scuola Superiore Sant'Anna, Viale Rinaldo Piaggio 34, Pontedera, 56025, Italy
- Department of Excellence in Robotics & AI, Scuola Superiore Sant'Anna, Piazza Martiri della Libertà 33, Pisa, 56127, Italy
| | - Attilio Marino
- Smart Bio-Interfaces, Istituto Italiano di Tecnologia, Viale Rinaldo Piaggio 34, Pontedera, 56025, Italy
| | - Gianni Ciofani
- Smart Bio-Interfaces, Istituto Italiano di Tecnologia, Viale Rinaldo Piaggio 34, Pontedera, 56025, Italy
| | - Aleksandra Szkudlarek
- Academic Centre for Materials and Nanotechnology, AGH University of Krakow, av. Mickiewicza 30, Krakow, 30-059, Poland
| | - Vitaliy Bilovol
- Academic Centre for Materials and Nanotechnology, AGH University of Krakow, av. Mickiewicza 30, Krakow, 30-059, Poland
| | - Krystian Sokolowski
- Academic Centre for Materials and Nanotechnology, AGH University of Krakow, av. Mickiewicza 30, Krakow, 30-059, Poland
| | - Birgit Kunert
- Institute of Solid State Physics, NAWI Graz, Graz University of Technology, Petersgasse 16, Graz, 8010, Austria
| | - Hana Kristin Hampel
- Institute of Experimental Physics, NAWI Graz, Graz University of Technology, Petersgasse 16, Graz, 8010, Austria
| | - Hilda Gomez Bernal
- The Biorobotics Institute, Scuola Superiore Sant'Anna, Viale Rinaldo Piaggio 34, Pontedera, 56025, Italy
| | - Francesco Greco
- The Biorobotics Institute, Scuola Superiore Sant'Anna, Viale Rinaldo Piaggio 34, Pontedera, 56025, Italy
- Department of Excellence in Robotics & AI, Scuola Superiore Sant'Anna, Piazza Martiri della Libertà 33, Pisa, 56127, Italy
- Institute of Solid State Physics, NAWI Graz, Graz University of Technology, Petersgasse 16, Graz, 8010, Austria
- Interdisciplinary Center on Sustainability and Climate, Scuola Superiore Sant'Anna, Piazza Martiri della Libertà 33, Pisa, 56127, Italy
| |
Collapse
|
11
|
Li L, Han Y, Zhang Y, Wu W, Du W, Wen G, Cheng S. Laser-Induced Graphene Decorated with MOF-Derived NiCo-LDH for Highly Sensitive Non-Enzymatic Glucose Sensor. Molecules 2024; 29:5662. [PMID: 39683820 DOI: 10.3390/molecules29235662] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2024] [Revised: 11/26/2024] [Accepted: 11/29/2024] [Indexed: 12/18/2024] Open
Abstract
Designing and fabricating a highly sensitive non-enzymatic glucose sensor is crucial for the early detection and management of diabetes. Meanwhile, the development of innovative electrode substrates has become a key focus for addressing the growing demand for constructing flexible sensors. Here, a simple one-step laser engraving method is applied for preparing laser-induced graphene (LIG) on polyimide (PI) film, which serves as the sensor substrate. NiCo-layered double hydroxides (NiCo-LDH) are synthesized on LIG as a precursor, utilizing the zeolitic imidazolate framework (ZIF-67), and then reacted with Ni(NO3)2 via solvent-thermal methods. The sensitivity of the non-enzymatic electrochemical glucose sensor is significantly improved by employing NiCo-LDH/LIG as the sensing material. The porous and interconnected structure of NiCo-LDH, derived from ZIF-67, enhances the accessibility of electrochemically active sites, while the incorporation of LIG ensures exceptional conductivity. The combination of NiCo-LDH with LIG enables efficient electron transport, leading to an increased electrochemically active surface area and enhanced catalytic efficiency. The fabricated electrode achieves a low glucose detection limit of 0.437 μM and demonstrates a high sensitivity of 1141.2 and 631.1 μA mM-2 cm-2 within the linear ranges of 0-770 μM and 770-1970 μM, respectively. Furthermore, the NiCo-LDH/LIG glucose sensor demonstrates superior reliability and little impact from other substances. A flexible integrated LIG-based non-enzymatic glucose sensor has been developed, demonstrating high sensitivity and suggesting a promising application for LIG-based chemical sensors.
Collapse
Affiliation(s)
- Longxiao Li
- School of Mechanical Engineering and Electronic Information, China University of Geosciences, Wuhan 430074, China
| | - Yufei Han
- School of Mechanical Engineering and Electronic Information, China University of Geosciences, Wuhan 430074, China
| | - Yuzhe Zhang
- School of Mechanical Engineering and Electronic Information, China University of Geosciences, Wuhan 430074, China
| | - Weijia Wu
- School of Mechanical Engineering and Electronic Information, China University of Geosciences, Wuhan 430074, China
| | - Wei Du
- School of Mechanical Engineering and Electronic Information, China University of Geosciences, Wuhan 430074, China
| | - Guojun Wen
- School of Mechanical Engineering and Electronic Information, China University of Geosciences, Wuhan 430074, China
| | - Siyi Cheng
- School of Mechanical Engineering and Electronic Information, China University of Geosciences, Wuhan 430074, China
| |
Collapse
|
12
|
Clark KM, Nekoba DT, Viernes KL, Zhou J, Ray TR. Fabrication of high-resolution, flexible, laser-induced graphene sensors via stencil masking. Biosens Bioelectron 2024; 264:116649. [PMID: 39137522 PMCID: PMC11368413 DOI: 10.1016/j.bios.2024.116649] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2024] [Revised: 07/19/2024] [Accepted: 08/07/2024] [Indexed: 08/15/2024]
Abstract
The advent of wearable sensing platforms capable of continuously monitoring physiological parameters indicative of health status have resulted in a paradigm shift for clinical medicine. The accessibility and adaptability of such portable, unobtrusive devices enables proactive, personalized care based on real-time physiological insights. While wearable sensing platforms exhibit powerful capabilities for continuously monitoring physiological parameters, device fabrication often requires specialized facilities and technical expertise, restricting deployment opportunities and innovation potential. The recent emergence of rapid prototyping approaches to sensor fabrication, such as laser-induced graphene (LIG), provides a pathway for circumventing these barriers through low-cost, scalable fabrication. However, inherent limitations in laser processing restrict the spatial resolution of LIG-based flexible electronic devices to the minimum laser spot size. For a CO2 laser-a commonly reported laser for device production-this corresponds to a feature size of ∼120 μm. Here, we demonstrate a facile, low-cost stencil-masking technique to reduce the minimum resolvable feature size of a LIG-based device from 120 ± 20 μm to 45 ± 3 μm when fabricated by CO2 laser. Characterization of device performance reveals this stencil-masked LIG (s-LIG) method yields a concomitant improvement in electrical properties, which we hypothesize is the result of changes in macrostructure of the patterned LIG. We showcase the performance of this fabrication method via production of common sensors including temperature and multi-electrode electrochemical sensors. We fabricate fine-line microarray electrodes not typically achievable via native CO2 laser processing, demonstrating the potential of the expanded design capabilities. Comparing microarray sensors made with and without the stencil to traditional macro LIG electrodes reveals the s-LIG sensors have significantly reduced capacitance for similar electroactive surface areas. Beyond improving sensor performance, the increased resolution enabled by this metal stencil technique expands capabilities for scalable fabrication of high-performance wearable sensors in low-resource settings without reliance on traditional fabrication pathways.
Collapse
Affiliation(s)
- Kaylee M Clark
- Department of Mechanical Engineering, University of Hawai'i at Mānoa, Honolulu, HI, 96822, USA
| | - Deylen T Nekoba
- Department of Mechanical Engineering, University of Hawai'i at Mānoa, Honolulu, HI, 96822, USA
| | - Kian Laʻi Viernes
- Department of Mechanical Engineering, University of Hawai'i at Mānoa, Honolulu, HI, 96822, USA
| | - Jie Zhou
- Department of Electrical Engineering, University of Hawai'i at Mānoa, Honolulu, HI, 96822, USA
| | - Tyler R Ray
- Department of Mechanical Engineering, University of Hawai'i at Mānoa, Honolulu, HI, 96822, USA; Department of Cell and Molecular Biology, John. A. Burns School of Medicine, University of Hawai'i at Mānoa, Honolulu, HI, 96813, USA.
| |
Collapse
|
13
|
Xu K, Cai Z, Luo H, Lu Y, Ding C, Yang G, Wang L, Kuang C, Liu J, Yang H. Toward Integrated Multifunctional Laser-Induced Graphene-Based Skin-Like Flexible Sensor Systems. ACS NANO 2024; 18:26435-26476. [PMID: 39288275 DOI: 10.1021/acsnano.4c09062] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/19/2024]
Abstract
The burgeoning demands for health care and human-machine interfaces call for the next generation of multifunctional integrated sensor systems with facile fabrication processes and reliable performances. Laser-induced graphene (LIG) with highly tunable physical and chemical characteristics plays vital roles in developing versatile skin-like flexible or stretchable sensor systems. This Progress Report presents an in-depth overview of the latest advances in LIG-based techniques in the applications of flexible sensors. First, the merits of the LIG technique are highlighted especially as the building blocks for flexible sensors, followed by the description of various fabrication methods of LIG and its variants. Then, the focus is moved to diverse LIG-based flexible sensors, including physical sensors, chemical sensors, and electrophysiological sensors. Mechanisms and advantages of LIG in these scenarios are described in detail. Furthermore, various representative paradigms of integrated LIG-based sensor systems are presented to show the capabilities of LIG technique for multipurpose applications. The signal cross-talk issues are discussed with possible strategies. The LIG technology with versatile functionalities coupled with other fabrication strategies will enable high-performance integrated sensor systems for next-generation skin electronics.
Collapse
Affiliation(s)
- Kaichen Xu
- State Key Laboratory of Fluid Power & Mechatronic Systems, School of Mechanical Engineering, Zhejiang University, Hangzhou 310058, P. R. China
| | - Zimo Cai
- State Key Laboratory of Fluid Power & Mechatronic Systems, School of Mechanical Engineering, Zhejiang University, Hangzhou 310058, P. R. China
| | - Huayu Luo
- State Key Laboratory of Fluid Power & Mechatronic Systems, School of Mechanical Engineering, Zhejiang University, Hangzhou 310058, P. R. China
| | - Yuyao Lu
- State Key Laboratory of Fluid Power & Mechatronic Systems, School of Mechanical Engineering, Zhejiang University, Hangzhou 310058, P. R. China
| | - Chenliang Ding
- State Key Laboratory of Modern Optical Instrumentation, College of Optical Science and Engineering, Zhejiang University, Hangzhou 310058, P. R. China
| | - Geng Yang
- State Key Laboratory of Fluid Power & Mechatronic Systems, School of Mechanical Engineering, Zhejiang University, Hangzhou 310058, P. R. China
| | - Lili Wang
- State Key Laboratory for Superlattices and Microstructures, Institute of Semiconductors, Chinese Academy of Sciences, Beijing 100083, P. R. China
| | - Cuifang Kuang
- State Key Laboratory of Modern Optical Instrumentation, College of Optical Science and Engineering, Zhejiang University, Hangzhou 310058, P. R. China
| | - Jingquan Liu
- National Key Laboratory of Advanced Micro and Nano Manufacture Technology, Shanghai Jiao Tong University, Shanghai 200240, P. R. China
| | - Huayong Yang
- State Key Laboratory of Fluid Power & Mechatronic Systems, School of Mechanical Engineering, Zhejiang University, Hangzhou 310058, P. R. China
| |
Collapse
|
14
|
Aftab S, Koyyada G, Mukhtar M, Kabir F, Nazir G, Memon SA, Aslam M, Assiri MA, Kim JH. Laser-Induced Graphene for Advanced Sensing: Comprehensive Review of Applications. ACS Sens 2024; 9:4536-4554. [PMID: 39284075 DOI: 10.1021/acssensors.4c01717] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/28/2024]
Abstract
Laser-induced graphene (LIG) and Laser-scribed graphene (LSG) are both advanced materials with significant potential in various applications, particularly in the field of sustainable sensors. The practical uses of LIG (LSG), which include gas detection, biological process monitoring, strain assessment, and environmental variable tracking, are thoroughly examined in this review paper. Its tunable characteristics distinguish LIG (LSG), which is developed from accurate laser beam modulation on polymeric substrates, and they are essential in advancing sensing technologies in many applications. The recent advances in LIG (LSG) applications include energy storage, biosensing, and electronics by steadily advancing efficiency and versatility. The remarkable flexibility of LIG (LSG) and its transformative potential in regard to sensor manufacturing and utilization are highlighted in this manuscript. Moreover, it thoroughly examines the various fabrication methods used in LIG (LSG) production, highlighting precision and adaptability. This review navigates the difficulties that are encountered in regard to implementing LIG sensors and looks ahead to future developments that will propel the industry forward. This paper provides a comprehensive summary of the latest research in LIG (LSG) and elucidates this innovative material's advanced and sustainable elements.
Collapse
Affiliation(s)
- Sikandar Aftab
- Department of Semiconductor Systems Engineering and Clean Energy, Sejong University, Seoul 05006, Republic of Korea
- Department of Artificial Intelligence and Robotics, Sejong University, Seoul 05006, Republic of Korea
| | - Ganesh Koyyada
- School of Chemical Engineering, Yeungnam University, Gyeongsan 38541, Republic of Korea
- Department of Chemistry, School of Sciences, SR University, Warangal 506371, Telangana, India
| | - Maria Mukhtar
- Department of Semiconductor Systems Engineering and Clean Energy, Sejong University, Seoul 05006, Republic of Korea
- Department of Artificial Intelligence and Robotics, Sejong University, Seoul 05006, Republic of Korea
| | - Fahmid Kabir
- School of Engineering Science, Simon Fraser University, Burnaby, V5A 1S6 British Columbia, Canada
| | - Ghazanfar Nazir
- Department of Nanotechnology and Advanced Materials Engineering, Hybrid Materials Research Center (HMC), Sejong University, Seoul 05006, Republic of Korea
| | - Sufyan Ali Memon
- Defense Systems Engineering Sejong University, Seoul 05006, South Korea
| | - Muhammad Aslam
- Institute of Physics and Technology, Ural Federal University, Mira Street 19, Ekaterinburg 620002, Russia
| | - Mohammed A Assiri
- Chemistry Department, Faculty of Science, King Khalid University, P.O. Box 9004, Abha 61413, Saudi Arabia
| | - Jae Hong Kim
- School of Chemical Engineering, Yeungnam University, Gyeongsan 38541, Republic of Korea
| |
Collapse
|
15
|
Adil O, Adeyeye C, Shamsi MH. Electrografted Laser-Induced Graphene: Direct Detection of Neurodegenerative Disease Biomarker in Cerebrospinal Fluid. ACS Sens 2024; 9:4748-4757. [PMID: 39145609 DOI: 10.1021/acssensors.4c01150] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/16/2024]
Abstract
There are more than 50 neurodegenerative disorders, and amyotrophic lateral sclerosis (ALS) is one of the most common disorders that poses diagnostic and treatment challenges. The poly glycine-proline (polyGP) dipeptide repeat is a toxic protein that has been recognized as a pharmacodynamic biomarker of C9orf72-associated (c9+) ALS, a subtype of ALS that originates from genetic mutation. Early detection of polyGP will help healthcare providers start timely gene therapy. Herein, we developed a label-free electrochemical immunoassay for the simple detection of polyGP in unprocessed cerebrospinal fluid (CSF) samples collected from ALS patients in the National ALS Biorepository. For the first time, an electrografted laser-induced graphene (E-LIG) electrode system was employed in a sandwich format to detect polyGP using a label-free electrochemical impedance technique. The results show that the E-LIG-modified surface exhibited high sensitivity and selectivity in buffer and CSF media with limit of detection values of 0.19 and 0.27 ng/mL, respectively. The precision of the calibration model was better in CSF than in the buffer. The E-LIG immunosensor can easily select polyGP targets in the presence of other dipeptide proteins translated from the c9 gene. Further study with CSF samples from ALS patients demonstrated that the label-free E-LIG-based immunosensor not only quantified polyGP in the complex CSF matrix but also distinguished between c9+ and non-c9- ALS patients.
Collapse
Affiliation(s)
- Omair Adil
- School of Chemical and Biomolecular Sciences, Southern Illinois University at Carbondale, Carbondale, Illinois 62901, United States
| | - Comfort Adeyeye
- School of Biological Sciences, Southern Illinois University at Carbondale, Carbondale, Illinois 62901, United States
| | - Mohtashim H Shamsi
- School of Chemical and Biomolecular Sciences, Southern Illinois University at Carbondale, Carbondale, Illinois 62901, United States
| |
Collapse
|
16
|
Amirghasemi F, Al-Shami A, Ushijima K, Mousavi MPS. Flexible Acetylcholine Neural Probe with a Hydrophobic Laser-Induced Graphene Electrode and a Fluorous-Phase Sensing Membrane. ACS MATERIALS LETTERS 2024; 6:4158-4167. [PMID: 39309214 PMCID: PMC11415234 DOI: 10.1021/acsmaterialslett.4c00825] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/25/2024]
Abstract
This work develops the first laser-induced graphene (LIG)-based electrochemical sensor with a superhydrophobic fluorous membrane for a flexible acetylcholine (ACh) sensor. ACh regulates several physiological functions, including synaptic transmission and glandular secretion. The ACh sensing membrane is doped with a fluorophilic cation-exchanger that can selectively measure ACh based on the inherent selectivity of the fluorous phase for hydrophobic ions, such as ACh. The fluorous-phase sensor improves the selectivity for ACh over Na+ and K+ by 2 orders of magnitude (compared to traditional lipophilic membranes), thus lowering the detection limit in artificial cerebrospinal fluid (aCSF) from 331 to 0.38 μ M, thereby allowing measurement in physiologically relevant ranges of ACh. Engraving LIG under argon creates a hydrophobic surface with a 133.7° contact angle, which minimizes the formation of a water layer. The flexible solid-contact LIG fluorous sensor exhibited a slope of 59.3 mV/decade in aCSF and retained function after 20 bending cycles, thereby paving the way for studying ACh's role in memory and neurodegenerative diseases.
Collapse
Affiliation(s)
- Farbod Amirghasemi
- Alfred E. Mann Department of Biomedical Engineering, Viterbi School of Engineering, University of Southern California, Los Angeles, California 90089, United States
| | - Abdulrahman Al-Shami
- Alfred E. Mann Department of Biomedical Engineering, Viterbi School of Engineering, University of Southern California, Los Angeles, California 90089, United States
| | - Kara Ushijima
- Alfred E. Mann Department of Biomedical Engineering, Viterbi School of Engineering, University of Southern California, Los Angeles, California 90089, United States
| | - Maral P S Mousavi
- Alfred E. Mann Department of Biomedical Engineering, Viterbi School of Engineering, University of Southern California, Los Angeles, California 90089, United States
| |
Collapse
|
17
|
Su R, Liang M, Yuan Y, Huang C, Xing W, Bian X, Lian Y, Wang B, You Z, You R. High-Performance Sensing Platform Based on Morphology/Lattice Collaborative Control of Femtosecond-Laser-Induced MXene-Composited Graphene. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2024; 11:e2404889. [PMID: 39041832 PMCID: PMC11423250 DOI: 10.1002/advs.202404889] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/06/2024] [Revised: 06/29/2024] [Indexed: 07/24/2024]
Abstract
Flexible sensors based on laser-induced graphene (LIG) are widely used in wearable personal devices, with the morphology and lattice arrangement of LIG the key factors affecting their performance in various applications. In this study, femtosecond-laser-induced MXene-composited graphene (LIMG) is used to improve the electrical conductivity of graphene by incorporating MXene, a 2D material with a high concentration of free electrons, into the LIG structure. By combining pump-probe detection, laser-induced breakdown spectroscopy (LIBS), and density functional theory (DFT) calculations, the morphogenesis and lattice structuring principles of LIMG is explored, with the results indicating that MXene materials are successfully embedded in the graphene lattice, altering both their morphology and electrical properties. The structural sparsity and electrical conductivity of LIMG composites (up to 3187 S m-1) are significantly enhanced compared to those of LIG. Based on these findings, LIMG has been used in wearable electronics. LIMG electrodes are used to detect uric acid, with a minimum detection limit of 2.48 µM. Additionally, LIMG-based pressure and bending sensors have been successfully used to monitor human limb movement and pulse. The direct in situ femtosecond laser patterning synthesis of LIMG has significant implications for developing flexible wearable electronic sensors.
Collapse
Affiliation(s)
- Ruige Su
- Laboratory of the Intelligent Microsystem, Beijing Information Science and Technology University, Beijing, 100192, P. R. China
- School of Instrument Science and Opto-Electronics Engineering, Beijing Information Science and Technology University, Beijing, 100192, P. R. China
| | - Misheng Liang
- Laboratory of the Intelligent Microsystem, Beijing Information Science and Technology University, Beijing, 100192, P. R. China
- School of Instrument Science and Opto-Electronics Engineering, Beijing Information Science and Technology University, Beijing, 100192, P. R. China
| | - Yongjiu Yuan
- Department of Mechanical Engineering, City University of Hong Kong, Hong Kong, 999077, P. R. China
| | - Chaojun Huang
- Laboratory of the Intelligent Microsystem, Beijing Information Science and Technology University, Beijing, 100192, P. R. China
- School of Instrument Science and Opto-Electronics Engineering, Beijing Information Science and Technology University, Beijing, 100192, P. R. China
| | - Wenqiang Xing
- Laboratory of the Intelligent Microsystem, Beijing Information Science and Technology University, Beijing, 100192, P. R. China
- School of Instrument Science and Opto-Electronics Engineering, Beijing Information Science and Technology University, Beijing, 100192, P. R. China
| | - Xiaomeng Bian
- Laboratory of the Intelligent Microsystem, Beijing Information Science and Technology University, Beijing, 100192, P. R. China
- School of Instrument Science and Opto-Electronics Engineering, Beijing Information Science and Technology University, Beijing, 100192, P. R. China
| | - Yiling Lian
- School of Mechanical Engineering, Beijing Institute of Technology, Beijing, 100081, P. R. China
| | - Bo Wang
- Institute of Medical Equipment Science and Engineering, Huazhong University of Science and Technology, Wuhan, 430074, P. R. China
| | - Zheng You
- State Key Laboratory of Precision Testing Technology and Instruments, Tsinghua University, Beijing, 100084, P. R. China
| | - Rui You
- Laboratory of the Intelligent Microsystem, Beijing Information Science and Technology University, Beijing, 100192, P. R. China
- School of Instrument Science and Opto-Electronics Engineering, Beijing Information Science and Technology University, Beijing, 100192, P. R. China
| |
Collapse
|
18
|
Zhong H, Lu X, Yang R, Pan Y, Lin J, Kim M, Chen S, Li MG. Seeing Through Muddy Water: Laser-Induced Graphene for Portable Tomography Imaging. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2024; 11:e2406905. [PMID: 39007503 PMCID: PMC11425229 DOI: 10.1002/advs.202406905] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/24/2024] [Indexed: 07/16/2024]
Abstract
Due to its outstanding physical and chemical properties, graphene synthesized by laser scribing on polyimide (PI) offers excellent opportunities for photothermal applications, antiviral and antibacterial surfaces, and electrochemical storage and sensing. However, the utilization of such graphene for imaging is yet to be explored. Herein, using chemically durable and electrically conductive laser-induced graphene (LIG) for tomography imaging in aqueous suspensions is proposed. These graphene electrodes are designed as impedance imaging units for four-terminal electrical measurements. Using the real-time portable imaging prototypes, the conductive and dielectric objects can be seen in clear and muddy water with equivalent impedance modeling. This low-cost graphene tomography measurement system offers significant advantages over traditional visual cameras, in which the suspended muddy particles hinder the imaging resolution. This research shows the potential of applying graphene nanomaterials in emerging marine technologies, such as underwater robotics and automatic fisheries.
Collapse
Affiliation(s)
- Haosong Zhong
- Center on Smart Manufacturing, Division of Integrative Systems and Design, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong SAR, China
| | - Xupeng Lu
- Center on Smart Manufacturing, Division of Integrative Systems and Design, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong SAR, China
| | - Rongliang Yang
- Center on Smart Manufacturing, Division of Integrative Systems and Design, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong SAR, China
| | - Yexin Pan
- Center on Smart Manufacturing, Division of Integrative Systems and Design, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong SAR, China
| | - Jing Lin
- Center on Smart Manufacturing, Division of Integrative Systems and Design, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong SAR, China
| | - Minseong Kim
- Center on Smart Manufacturing, Division of Integrative Systems and Design, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong SAR, China
| | - Siyu Chen
- Center on Smart Manufacturing, Division of Integrative Systems and Design, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong SAR, China
| | - Mitch Guijun Li
- Center on Smart Manufacturing, Division of Integrative Systems and Design, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong SAR, China
| |
Collapse
|
19
|
Chen R, Liu S, Zhang C, Jiang C, Zhou W, Chen P, Wu D, Li D, Zhang J, Luo T. Laser Fabrication of Humidity Sensors on Ethanol-Soaked Polyimide for Fully Contactless Respiratory Monitoring. ACS APPLIED MATERIALS & INTERFACES 2024; 16:45252-45264. [PMID: 39139068 DOI: 10.1021/acsami.4c07731] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/15/2024]
Abstract
Humidity-sensor-based fully contactless respiratory monitoring can eliminate the discomfort and infection risks associated with any wearable device. However, challenges in the facile fabrication of highly sensitive humidity sensors continue to hinder their widespread application for fully contactless respiratory monitoring. In this study, we introduce a simple method to fabricate highly sensitive humidity sensors. Our method employs laser-induced graphene (LIG) on an ethanol-soaked polyimide (PI) film as the electrode of the humidity sensor. The ethanol-soaked PI between adjacent LIG electrodes functions as the sensing material, enabling ion-conductive humidity sensing. Compared to the LIG humidity sensors fabricated on untreated PI films, LIG humidity sensors fabricated on ethanol-soaked PI films exhibit superior performance with higher linearity (R2 = 0.9936), reduced hysteresis (ΔH = 5.1% RH), and increased sensitivity (0.65%/RH). Notably, the LIG humidity sensor fabricated on the ethanol-soaked PI film can detect a person's breathing from a distance of 30 cm, a capability not achieved by sensors fabricated on untreated PI films. Moreover, incorporating these LIG humidity sensors into an array further enhances both the detection distance and the sensitivity for respiratory monitoring. Experimental results demonstrate that the LIG humidity sensor array can be employed for fully contactless on-bed respiration monitoring and for continuous, fully contactless monitoring of the respiratory rate during treadmill exercise. These results highlight the great potential of our LIG humidity sensors for various practical applications in medicine and sports.
Collapse
Affiliation(s)
- Rui Chen
- Pen-Tung Sah Institute of Micro-Nano Science and Technology, Xiamen University, Xiamen 361102, China
- School of Aerospace Engineering, Xiamen University, Xiamen 361102, China
| | - Sirui Liu
- Pen-Tung Sah Institute of Micro-Nano Science and Technology, Xiamen University, Xiamen 361102, China
| | - Chen Zhang
- Pen-Tung Sah Institute of Micro-Nano Science and Technology, Xiamen University, Xiamen 361102, China
| | - Chongjie Jiang
- Pen-Tung Sah Institute of Micro-Nano Science and Technology, Xiamen University, Xiamen 361102, China
| | - Wei Zhou
- Pen-Tung Sah Institute of Micro-Nano Science and Technology, Xiamen University, Xiamen 361102, China
| | - Pengfeng Chen
- Pen-Tung Sah Institute of Micro-Nano Science and Technology, Xiamen University, Xiamen 361102, China
| | - Dezhi Wu
- Pen-Tung Sah Institute of Micro-Nano Science and Technology, Xiamen University, Xiamen 361102, China
| | - Dongxia Li
- Physical Education Department, Xiamen University, Xiamen 361102, China
| | - Jinhui Zhang
- Pen-Tung Sah Institute of Micro-Nano Science and Technology, Xiamen University, Xiamen 361102, China
| | - Tao Luo
- Pen-Tung Sah Institute of Micro-Nano Science and Technology, Xiamen University, Xiamen 361102, China
| |
Collapse
|
20
|
Sengupta J, Hussain CM. Sensitive and selective detection of heavy metal ions and organic pollutants with graphene-integrated sensing platforms. NANOSCALE 2024; 16:14195-14212. [PMID: 39016018 DOI: 10.1039/d4nr00956h] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 07/18/2024]
Abstract
Graphene-based sensors have emerged as promising tools for environmental monitoring due to their exceptional properties such as high surface area, excellent electrical conductivity, and sensitivity to various analytes. This paper presents a review of recent advancements in the development and application of graphene-based sensors for the detection of heavy metal ions and organic pollutants. These sensors employ either graphene or its derivatives, often in combination with graphene hybrid nanocomposites, as the primary sensing material. The synthesis methods of graphene and sensing mechanisms of graphene-based sensors are discussed. Furthermore, performance metrics including the determination range and detection limits of these sensors are itemized. The potential challenges and future directions in the field of graphene-based sensors for environmental monitoring are also highlighted. Overall, this review provides valuable insights into the current state-of-the-art technologies and paves the way for the development of highly efficient and reliable sensors for environmental monitoring purposes.
Collapse
Affiliation(s)
- Joydip Sengupta
- Department of Electronic Science, Jogesh Chandra Chaudhuri College, Kolkata - 700033, India.
| | - Chaudhery Mustansar Hussain
- Department of Chemistry and Environmental Science, New Jersey Institute of Technology, Newark, 07102, New Jersey, USA.
| |
Collapse
|
21
|
Park H, Park JJ, Bui PD, Yoon H, Grigoropoulos CP, Lee D, Ko SH. Laser-Based Selective Material Processing for Next-Generation Additive Manufacturing. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2024; 36:e2307586. [PMID: 37740699 DOI: 10.1002/adma.202307586] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/29/2023] [Revised: 09/14/2023] [Indexed: 09/25/2023]
Abstract
The connection between laser-based material processing and additive manufacturing is quite deeply rooted. In fact, the spark that started the field of additive manufacturing is the idea that two intersecting laser beams can selectively solidify a vat of resin. Ever since, laser has been accompanying the field of additive manufacturing, with its repertoire expanded from processing only photopolymer resin to virtually any material, allowing liberating customizability. As a result, additive manufacturing is expected to take an even more prominent role in the global supply chain in years to come. Herein, an overview of laser-based selective material processing is presented from various aspects: the physics of laser-material interactions, the materials currently used in additive manufacturing processes, the system configurations that enable laser-based additive manufacturing, and various functional applications of next-generation additive manufacturing. Additionally, current challenges and prospects of laser-based additive manufacturing are discussed.
Collapse
Affiliation(s)
- Huijae Park
- Applied Nano and Thermal Science Lab, Department of Mechanical Engineering, Seoul National University, 1 Gwanak-ro, Gwanak-gu, Seoul, 08826, South Korea
| | - Jung Jae Park
- Applied Nano and Thermal Science Lab, Department of Mechanical Engineering, Seoul National University, 1 Gwanak-ro, Gwanak-gu, Seoul, 08826, South Korea
| | - Phuong-Danh Bui
- Laser and Thermal Engineering Lab, Department of Mechanical Engineering, Gachon University, 1342 Seongnamdaero, Sujeong-gu, Seongnam, 13120, South Korea
| | - Hyeokjun Yoon
- Applied Nano and Thermal Science Lab, Department of Mechanical Engineering, Seoul National University, 1 Gwanak-ro, Gwanak-gu, Seoul, 08826, South Korea
| | - Costas P Grigoropoulos
- Laser Thermal Lab, Department of Mechanical Engineering, University of California at Berkeley, Berkeley, CA, 94720, USA
| | - Daeho Lee
- Laser and Thermal Engineering Lab, Department of Mechanical Engineering, Gachon University, 1342 Seongnamdaero, Sujeong-gu, Seongnam, 13120, South Korea
| | - Seung Hwan Ko
- Applied Nano and Thermal Science Lab, Department of Mechanical Engineering, Seoul National University, 1 Gwanak-ro, Gwanak-gu, Seoul, 08826, South Korea
| |
Collapse
|
22
|
Tene T, Bellucci S, Arias Arias F, Carrera Almendariz LS, Flores Huilcapi AG, Vacacela Gomez C. Role of Graphene in Surface Plasmon Resonance-Based Biosensors. SENSORS (BASEL, SWITZERLAND) 2024; 24:4670. [PMID: 39066066 PMCID: PMC11280817 DOI: 10.3390/s24144670] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/19/2024] [Revised: 07/08/2024] [Accepted: 07/16/2024] [Indexed: 07/28/2024]
Abstract
This work explores the transformative role of graphene in enhancing the performance of surface plasmon resonance (SPR)-based biosensors. The motivation for this review stems from the growing interest in the unique properties of graphene, such as high surface area, excellent electrical conductivity, and versatile functionalization capabilities, which offer significant potential to improve the sensitivity, specificity, and stability of SPR biosensors. This review systematically analyzes studies published between 2010 and 2023, covering key metrics of biosensor performance. The findings reveal that the integration of graphene consistently enhances sensitivity. Specificity, although less frequently reported numerically, showed promising results, with high specificity achieved at sub-nanomolar concentrations. Stability enhancements are also significant, attributed to the protective properties of graphene and improved biomolecule adsorption. Future research should focus on mechanistic insights, optimization of integration techniques, practical application testing, scalable fabrication methods, and comprehensive comparative studies. Our findings provide a foundation for future research, aiming to further optimize and harness the unique physical properties of graphene to meet the demands of sensitive, specific, stable, and rapid biosensing in various practical applications.
Collapse
Affiliation(s)
- Talia Tene
- Department of Chemistry, Universidad Técnica Particular de Loja, Loja 110160, Ecuador;
| | - Stefano Bellucci
- INFN-Laboratori Nazionali di Frascati, Via E. Fermi 54, I-00044 Frascati, Italy
| | - Fabian Arias Arias
- Facultad de Ciencias, Escuela Superior Politécnica de Chimborazo (ESPOCH), Riobamba 060155, Ecuador
- Dipartimento di Chimica e Tecnologie Chimiche, University of Calabria, Via P. Bucci, Cubo 15D, I-87036 Rende, Italy
| | | | - Ana Gabriela Flores Huilcapi
- Facultad de Ciencia e Ingeniería en Alimentos y Biotecnología, Universidad Técnica de Ambato, Ambato 180104, Ecuador
| | | |
Collapse
|
23
|
Pan Y, Su X, Liu Y, Fan P, Li X, Ying Y, Ping J. A laser-Engraved Wearable Electrochemical Sensing Patch for Heat Stress Precise Individual Management of Horse. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2024; 11:e2310069. [PMID: 38728620 PMCID: PMC11267262 DOI: 10.1002/advs.202310069] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/21/2023] [Revised: 04/19/2024] [Indexed: 05/12/2024]
Abstract
In point-of-care diagnostics, the continuous monitoring of sweat constituents provides a window into individual's physiological state. For species like horses, with abundant sweat glands, sweat composition can serve as an early health indicator. Considering the salience of such metrics in the domain of high-value animal breeding, a sophisticated wearable sensor patch tailored is introduced for the dynamic assessment of equine sweat, offering insights into pH, potassium ion (K+), and temperature profiles during episodes of heat stress and under normal physiological conditions. The device integrates a laser-engraved graphene (LEG) sensing electrode array, a non-invasive iontophoretic module for stimulated sweat secretion, an adaptable signal processing unit, and an embedded wireless communication framework. Profiting from an admirable Truth Table capable of logical evaluation, the integrated system enabled the early and timely assessment for heat stress, with high accuracy, stability, and reproducibility. The sensor patch has been calibrated to align with the unique dermal and physiological contours of equine anatomy, thereby augmenting its applicability in practical settings. This real-time analysis tool for equine perspiration stands to revolutionize personalized health management approaches for high-value animals, marking a significant stride in the integration of smart technologies within the agricultural sector.
Collapse
Affiliation(s)
- Yuxiang Pan
- Laboratory of Agricultural Information Intelligent SensingCollege of Biosystems Engineering and Food ScienceZhejiang UniversityHangzhou310058P. R. China
- ZJU‐Hangzhou Global Scientific and Technological Innovation CenterZhejiang UniversityHangzhou311215P. R. China
| | - Xiaoyu Su
- Laboratory of Agricultural Information Intelligent SensingCollege of Biosystems Engineering and Food ScienceZhejiang UniversityHangzhou310058P. R. China
- ZJU‐Hangzhou Global Scientific and Technological Innovation CenterZhejiang UniversityHangzhou311215P. R. China
| | - Ying Liu
- Laboratory of Agricultural Information Intelligent SensingCollege of Biosystems Engineering and Food ScienceZhejiang UniversityHangzhou310058P. R. China
- ZJU‐Hangzhou Global Scientific and Technological Innovation CenterZhejiang UniversityHangzhou311215P. R. China
| | - Peidi Fan
- Laboratory of Agricultural Information Intelligent SensingCollege of Biosystems Engineering and Food ScienceZhejiang UniversityHangzhou310058P. R. China
| | - Xunjia Li
- Laboratory of Agricultural Information Intelligent SensingCollege of Biosystems Engineering and Food ScienceZhejiang UniversityHangzhou310058P. R. China
- ZJU‐Hangzhou Global Scientific and Technological Innovation CenterZhejiang UniversityHangzhou311215P. R. China
| | - Yibin Ying
- Laboratory of Agricultural Information Intelligent SensingCollege of Biosystems Engineering and Food ScienceZhejiang UniversityHangzhou310058P. R. China
- ZJU‐Hangzhou Global Scientific and Technological Innovation CenterZhejiang UniversityHangzhou311215P. R. China
| | - Jianfeng Ping
- Laboratory of Agricultural Information Intelligent SensingCollege of Biosystems Engineering and Food ScienceZhejiang UniversityHangzhou310058P. R. China
- ZJU‐Hangzhou Global Scientific and Technological Innovation CenterZhejiang UniversityHangzhou311215P. R. China
| |
Collapse
|
24
|
Zheng C, Liu R, Chen J, Li S, Ling Y, Zhang Z. Development of a selective electrochemical microsensor based on molecularly imprinted polydopamine/ZIF-67/laser-induced graphene for point-of-care determination of 3-nitrotyrosine. Biosens Bioelectron 2024; 255:116246. [PMID: 38537430 DOI: 10.1016/j.bios.2024.116246] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2024] [Revised: 03/22/2024] [Accepted: 03/23/2024] [Indexed: 04/15/2024]
Abstract
3-nitrotyrosine (3-NT) is a biomarker closely associated with the early diagnosis of oxidative stress-related disorders. The development of an accurate, cost-effective, point-of-care 3-NT sensor holds significant importance for self-monitoring and clinical treatment. In this study, a selective, sensitive, and portable molecularly imprinted electrochemical sensor was developed. ZIF-67 with strong adsorption capacity was facilely modified on an electrochemically active laser-induced graphene (LIG) substrate (formed ZIF-67/LIG). Subsequently, biocompatible dopamine was chosen as the functional monomer, and interference-free ʟ-tyrosine was used as the dummy template to create molecularly imprinted polydopamine (MIPDA) on the ZIF-67/LIG, endowing the sensor with selectivity. The morphologies, electrochemical properties, and detection performance of the sensor were comprehensively investigated using scanning electron microscopy, cyclic voltammetry, electrochemical impedance spectroscopy, and differential pulse voltammetry. To achieve the best performance, several parameters were optimized, including the number of polymerization cycles (15), elution time (60 min), incubation time (7 min), and pH of the buffer solution (6). The turnaround time for this sensor is 10 min. Benefiting from the alliance of MIPDA, ZIF-67, and LIG, the sensor exhibited excellent sensitivity with a detection limit of 6.71 nM, and distinguished selectivity against 11 interfering substances. To enable convenient clinical diagnosis, a customized electrochemical microsensor with MIPDA/ZIF-67/LIG was designed, showcasing excellent reliability and convenience in detecting biological samples without pretreatment. The proposed microsensor will not only facilitate clinical diagnosis and improve patient care, but also provide inspiration for the development of other portable and accurate electrochemical biosensors.
Collapse
Affiliation(s)
- Chibin Zheng
- Key Laboratory of Advanced Materials of Ministry of Education, School of Materials Science and Engineering, Tsinghua University, Beijing, 100084, PR China
| | - Ruwei Liu
- Key Laboratory of Advanced Materials of Ministry of Education, School of Materials Science and Engineering, Tsinghua University, Beijing, 100084, PR China
| | - Jianyue Chen
- Key Laboratory of Advanced Materials of Ministry of Education, School of Materials Science and Engineering, Tsinghua University, Beijing, 100084, PR China; Institute of New Functional Materials Co., Ltd, Guangxi Institute of Industrial Technology, Nanning, 530200, PR China
| | - Shilin Li
- Key Laboratory of Advanced Materials of Ministry of Education, School of Materials Science and Engineering, Tsinghua University, Beijing, 100084, PR China
| | - Yunhan Ling
- Key Laboratory of Advanced Materials of Ministry of Education, School of Materials Science and Engineering, Tsinghua University, Beijing, 100084, PR China.
| | - Zhengjun Zhang
- Key Laboratory of Advanced Materials of Ministry of Education, School of Materials Science and Engineering, Tsinghua University, Beijing, 100084, PR China
| |
Collapse
|
25
|
Qian H, Moreira G, Vanegas D, Tang Y, Pola C, Gomes C, McLamore E, Bliznyuk N. Improving high throughput manufacture of laser-inscribed graphene electrodes via hierarchical clustering. Sci Rep 2024; 14:7980. [PMID: 38575717 PMCID: PMC10995179 DOI: 10.1038/s41598-024-57932-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2024] [Accepted: 03/22/2024] [Indexed: 04/06/2024] Open
Abstract
Laser-inscribed graphene (LIG), initially developed for graphene supercapacitors, has found widespread use in sensor research and development, particularly as a platform for low-cost electrochemical sensing. However, batch-to-batch variation in LIG fabrication introduces uncertainty that cannot be adequately tracked during manufacturing process, limiting scalability. Therefore, there is an urgent need for robust quality control (QC) methodologies to identify and select similar and functional LIG electrodes for sensor fabrication. For the first time, we have developed a statistical workflow and an open-source hierarchical clustering tool for QC analysis in LIG electrode fabrication. The QC process was challenged with multi-operator cyclic voltammetry (CV) data for bare and metalized LIG. As a proof of concept, we employed the developed QC process for laboratory-scale manufacturing of LIG-based biosensors. The study demonstrates that our QC process can rapidly identify similar LIG electrodes from large batches (n ≥ 36) of electrodes, leading to a reduction in biosensor measurement variation by approximately 13% compared to the control group without QC. The statistical workflow and open-source code presented here provide a versatile toolkit for clustering analysis, opening a pathway toward scalable manufacturing of LIG electrodes in sensing. In addition, we establish a data repository for further study of LIG variation.
Collapse
Affiliation(s)
- Hanyu Qian
- Department of Agricultural and Biological Engineering, University of Florida, Gainesville, FL, 32611, USA
| | - Geisianny Moreira
- Department of Agricultural Sciences, Clemson University, Clemson, SC, 29634, USA
| | - Diana Vanegas
- Environmental Engineering and Earth Sciences Department of Engineering, Clemson University, Clemson, SC, 29634, USA
| | - Yifan Tang
- Department of Plant and Environmental Science, Clemson University, Clemson, SC, 29634, USA
| | - Cicero Pola
- Department of Mechanical Engineering, Iowa State University, Ames, IA, 50011, USA
| | - Carmen Gomes
- Department of Mechanical Engineering, Iowa State University, Ames, IA, 50011, USA
| | - Eric McLamore
- Department of Agricultural Sciences, Clemson University, Clemson, SC, 29634, USA.
- Environmental Engineering and Earth Sciences Department of Engineering, Clemson University, Clemson, SC, 29634, USA.
| | - Nikolay Bliznyuk
- Department of Agricultural and Biological Engineering, University of Florida, Gainesville, FL, 32611, USA.
- Departments of Statistics, Biostatistics and Electrical and Computer Engineering, University of Florida, Gainesville, FL, 32611, USA.
| |
Collapse
|
26
|
Hua Q, Shen G. Low-dimensional nanostructures for monolithic 3D-integrated flexible and stretchable electronics. Chem Soc Rev 2024; 53:1316-1353. [PMID: 38196334 DOI: 10.1039/d3cs00918a] [Citation(s) in RCA: 9] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2024]
Abstract
Flexible/stretchable electronics, which are characterized by their ultrathin design, lightweight structure, and excellent mechanical robustness and conformability, have garnered significant attention due to their unprecedented potential in healthcare, advanced robotics, and human-machine interface technologies. An increasing number of low-dimensional nanostructures with exceptional mechanical, electronic, and/or optical properties are being developed for flexible/stretchable electronics to fulfill the functional and application requirements of information sensing, processing, and interactive loops. Compared to the traditional single-layer format, which has a restricted design space, a monolithic three-dimensional (M3D) integrated device architecture offers greater flexibility and stretchability for electronic devices, achieving a high-level of integration to accommodate the state-of-the-art design targets, such as skin-comfort, miniaturization, and multi-functionality. Low-dimensional nanostructures possess small size, unique characteristics, flexible/elastic adaptability, and effective vertical stacking capability, boosting the advancement of M3D-integrated flexible/stretchable systems. In this review, we provide a summary of the typical low-dimensional nanostructures found in semiconductor, interconnect, and substrate materials, and discuss the design rules of flexible/stretchable devices for intelligent sensing and data processing. Furthermore, artificial sensory systems in 3D integration have been reviewed, highlighting the advancements in flexible/stretchable electronics that are deployed with high-density, energy-efficiency, and multi-functionalities. Finally, we discuss the technical challenges and advanced methodologies involved in the design and optimization of low-dimensional nanostructures, to achieve monolithic 3D-integrated flexible/stretchable multi-sensory systems.
Collapse
Affiliation(s)
- Qilin Hua
- School of Integrated Circuits and Electronics, Beijing Institute of Technology, Beijing 100081, China.
- Institute of Flexible Electronics, Beijing Institute of Technology, Beijing 102488, China
| | - Guozhen Shen
- School of Integrated Circuits and Electronics, Beijing Institute of Technology, Beijing 100081, China.
- Institute of Flexible Electronics, Beijing Institute of Technology, Beijing 102488, China
| |
Collapse
|
27
|
Xu K, Li Q, Lu Y, Luo H, Jian Y, Li D, Kong D, Wang R, Tan J, Cai Z, Yang G, Zhu B, Ye Q, Yang H, Li T. Laser Direct Writing of Flexible Thermal Flow Sensors. NANO LETTERS 2023; 23:10317-10325. [PMID: 37937967 DOI: 10.1021/acs.nanolett.3c02891] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/09/2023]
Abstract
Thin film-based thermal flow sensors afford applications in healthcare and industries owing to their merits in preserving initial flow distributions. However, traditional thermal flow sensors are primarily applied to track flow intensities based on hot-wire or hot-film sensing mechanisms due to their relatively facile device configurations and fabrication strategies. Herein, a calorimetric thermal flow sensor is proposed based on laser direct writing to form laser-induced graphene as heaters and temperature sensors, resulting in monitoring both flow intensities and orientations. Via homogeneously surrounding spiral heaters with multiple temperature sensors, the device exhibits high sensitivity (∼162 K·s/m) at small flows with an extended flow detection range (∼25 m/s). Integrating the device with a data-acquisition board and a dual-mode graphical user interface enables wirelessly and dynamically monitoring respiration and the motion of robotic arms. This versatile flow sensor with facile manufacturing affords potentials in health inspection, remote monitoring, and studying hydrodynamics.
Collapse
Affiliation(s)
- Kaichen Xu
- State Key Laboratory of Fluid Power and Mechatronic Systems, School of Mechanical Engineering, Zhejiang University, Hangzhou 310027, China
| | - Qi'ao Li
- State Key Laboratory of Fluid Power and Mechatronic Systems, School of Mechanical Engineering, Zhejiang University, Hangzhou 310027, China
| | - Yuyao Lu
- State Key Laboratory of Fluid Power and Mechatronic Systems, School of Mechanical Engineering, Zhejiang University, Hangzhou 310027, China
| | - Huayu Luo
- State Key Laboratory of Fluid Power and Mechatronic Systems, School of Mechanical Engineering, Zhejiang University, Hangzhou 310027, China
| | - Yihui Jian
- State Key Laboratory of Fluid Power and Mechatronic Systems, School of Mechanical Engineering, Zhejiang University, Hangzhou 310027, China
| | - Dingwei Li
- Key Laboratory of 3D Micro/Nano Fabrication and Characterization of Zhejiang Province, School of Engineering, Westlake University, Hangzhou 310024, Zhejiang, China
| | - Depeng Kong
- State Key Laboratory of Fluid Power and Mechatronic Systems, School of Mechanical Engineering, Zhejiang University, Hangzhou 310027, China
| | - Ruohan Wang
- State Key Laboratory of Fluid Power and Mechatronic Systems, School of Mechanical Engineering, Zhejiang University, Hangzhou 310027, China
| | - Jibing Tan
- State Key Laboratory of Fluid Power and Mechatronic Systems, School of Mechanical Engineering, Zhejiang University, Hangzhou 310027, China
| | - Zimo Cai
- State Key Laboratory of Fluid Power and Mechatronic Systems, School of Mechanical Engineering, Zhejiang University, Hangzhou 310027, China
| | - Geng Yang
- State Key Laboratory of Fluid Power and Mechatronic Systems, School of Mechanical Engineering, Zhejiang University, Hangzhou 310027, China
| | - Bowen Zhu
- Key Laboratory of 3D Micro/Nano Fabrication and Characterization of Zhejiang Province, School of Engineering, Westlake University, Hangzhou 310024, Zhejiang, China
| | - Qingqing Ye
- State Key Laboratory of Fluid Power and Mechatronic Systems, Department of Mechanics, Zhejiang University, Hangzhou 310027, China
| | - Huayong Yang
- State Key Laboratory of Fluid Power and Mechatronic Systems, School of Mechanical Engineering, Zhejiang University, Hangzhou 310027, China
| | - Tiefeng Li
- State Key Laboratory of Fluid Power and Mechatronic Systems, Zhejiang University, Hangzhou 310027, China
- Center for X-Mechanics, Department of Engineering Mechanics, Zhejiang University, 310027 Hangzhou, China
| |
Collapse
|
28
|
Peng Q, Zeng Q, Wang F, Wu X, Zhang R, Shi G, Zhang M. Multi-engineered Graphene Extended-Gate Field-Effect Transistor for Peroxynitrite Sensing in Alzheimer's Disease. ACS NANO 2023; 17:21984-21992. [PMID: 37874899 DOI: 10.1021/acsnano.3c08499] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/26/2023]
Abstract
The expression of β-amyloid peptides (Aβ), a pathological indicator of Alzheimer's disease (AD), was reported to be inapparent in the early stage of AD. While peroxynitrite (ONOO-) is produced excessively and emerges earlier than Aβ plaques in the progression of AD, it is thus significant to sensitively detect ONOO- for early diagnosis of AD and its pathological research. Herein, we unveiled an integrated sensor for monitoring ONOO-, which consisted of a commercially available field-effect transistor (FET) and a high-performance multi-engineered graphene extended-gate (EG) electrode. In the configuration of the presented EG electrode, laser-induced graphene (LIG) intercalated with MnO2 nanoparticles (MnO2/LIG) can improve the electrical properties of LIG and the sensitivity of the sensor, and graphene oxide (GO)-MnO2/Hemin nanozyme with ONOO- isomerase activity can selectively trigger the isomerization of ONOO- to NO3-. With this synergistic effect, our EG-FET sensor can respond to the ONOO- with high sensitivity and selectivity. Moreover, taking advantage of our EG-FET sensor, we modularly assembled a portable sensing platform for wireless tracking ONOO- levels in the brain tissue of AD transgenic mice at earlier stages before massive Aβ plaques appeared, and we systematically explored the complex role of ONOO- in the occurrence and development of AD.
Collapse
Affiliation(s)
- Qiwen Peng
- School of Chemistry and Molecular Engineering, Shanghai Key Laboratory for Urban Ecological Processes and Eco-Restoration, East China Normal University, Shanghai 200241, China
| | - Qiankun Zeng
- School of Chemistry and Molecular Engineering, Shanghai Key Laboratory for Urban Ecological Processes and Eco-Restoration, East China Normal University, Shanghai 200241, China
| | - Fangbing Wang
- School of Chemistry and Molecular Engineering, Shanghai Key Laboratory for Urban Ecological Processes and Eco-Restoration, East China Normal University, Shanghai 200241, China
| | - Xiaoyuan Wu
- School of Communication and Electric Engineering, East China Normal University, Shanghai 200241, China
| | - Runxi Zhang
- School of Communication and Electric Engineering, East China Normal University, Shanghai 200241, China
| | - Guoyue Shi
- School of Chemistry and Molecular Engineering, Shanghai Key Laboratory for Urban Ecological Processes and Eco-Restoration, East China Normal University, Shanghai 200241, China
| | - Min Zhang
- School of Chemistry and Molecular Engineering, Shanghai Key Laboratory for Urban Ecological Processes and Eco-Restoration, East China Normal University, Shanghai 200241, China
- Chongqing Key Laboratory of Precision Optics, Chongqing Institute of East China Normal University, Chongqing 401120, China
| |
Collapse
|
29
|
Zhao N, Zhang H, Yang S, Sun Y, Zhao G, Fan W, Yan Z, Lin J, Wan C. Direct Induction of Porous Graphene from Mechanically Strong and Waterproof Biopaper for On-Chip Multifunctional Flexible Electronics. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2023; 19:e2300242. [PMID: 37381614 DOI: 10.1002/smll.202300242] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/23/2023] [Revised: 06/05/2023] [Indexed: 06/30/2023]
Abstract
Graphene with a 3D porous structure is directly laser-induced on lignocellulosic biopaper under ambient conditions and is further explored for multifunctional biomass-based flexible electronics. The mechanically strong, flexible, and waterproof biopaper is fabricated by surface-functionalizing cellulose with lignin-based epoxy acrylate (LBEA). This composite biopaper shows as high as a threefold increase in tensile strength and excellent waterproofing compared with pure cellulose one. Direct laser writing (DLW) rapidly induces porous graphene from the biopaper in a single step. The porous graphene shows an interconnected carbon network, well-defined graphene domains, and high electrical conductivity (e.g., ≈3 Ω per square), which can be tuned by lignin precursors and loadings as well as lasing conditions. The biopaper in situ embedded with porous graphene is facilely fabricated into flexible electronics for on-chip and paper-based applications. The biopaper-based electronic devices, including the all-solid-state planer supercapacitor, electrochemical and strain biosensors, and Joule heater, show great performances. This study demonstrates the facile, versatile, and low-cost fabrication of multifunctional graphene-based electronics from lignocellulose-based biopaper.
Collapse
Affiliation(s)
- Nan Zhao
- Department of Chemical and Biomedical Engineering, University of Missouri, 1406 East Rollins Street, Columbia, MO, 65211, USA
- School of Ecology and Environment, Zhengzhou University, 100 Kexue Blvd, Zhengzhou, Henan Province, 450001, China
| | - Hanwen Zhang
- Department of Chemical and Biomedical Engineering, University of Missouri, 1406 East Rollins Street, Columbia, MO, 65211, USA
| | - Shuhong Yang
- Department of Chemical and Biomedical Engineering, University of Missouri, 1406 East Rollins Street, Columbia, MO, 65211, USA
| | - Yisheng Sun
- Department of Chemical and Biomedical Engineering, University of Missouri, 1406 East Rollins Street, Columbia, MO, 65211, USA
| | - Ganggang Zhao
- Department of Mechanical and Aerospace Engineering, University of Missouri, 416 South 6th Street, Columbia, MO, 65211, USA
| | - Wenjun Fan
- Department of Chemical and Biomedical Engineering, University of Missouri, 1406 East Rollins Street, Columbia, MO, 65211, USA
| | - Zheng Yan
- Department of Chemical and Biomedical Engineering, University of Missouri, 1406 East Rollins Street, Columbia, MO, 65211, USA
- Department of Mechanical and Aerospace Engineering, University of Missouri, 416 South 6th Street, Columbia, MO, 65211, USA
| | - Jian Lin
- Department of Mechanical and Aerospace Engineering, University of Missouri, 416 South 6th Street, Columbia, MO, 65211, USA
| | - Caixia Wan
- Department of Chemical and Biomedical Engineering, University of Missouri, 1406 East Rollins Street, Columbia, MO, 65211, USA
| |
Collapse
|
30
|
Xia J, Huang W, Majer-Baranyi K, Zhang M, Zhang X. Conformal Temperature/Impedance Sensing Patch Based on Graphene Materials for Nondestructive Detection of Fish Freshness. ACS APPLIED MATERIALS & INTERFACES 2023; 15:45095-45105. [PMID: 37708381 DOI: 10.1021/acsami.3c08621] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/16/2023]
Abstract
Rapid nondestructive detection of fish freshness is essential to ensure food safety and nutrition. In this study, we demonstrate a conformal temperature/impedance sensing patch for temperature monitoring, as well as freshness classification during fish storage. The optimization of the flexible laser-induced graphene electrodes is studied based on both simulation and experimental validation, and dimensional accuracy of 5‰ and high impedance reproducibility are obtained. A laser-assisted thermal reduction technology is innovatively introduced to directly form a reduced graphene oxide-based temperature-sensitive layer on the surface of a flexible substrate. The comprehensive performance is superior to that of most reported temperature-sensitive devices based on graphene materials. As an application demonstration, the fabricated flexible dual-parameter sensing patch is conformed to the surface of a refrigerated fish. The patch demonstrates the ability to accurately sense low temperatures in a continuous 120 min monitoring, accompanied by no interference from high humidity. Meanwhile, the collected impedance data are imported into the support vector machine model to obtain a freshness classification accuracy of 93.07%. The conformal patch integrated with crosstalk-free dual functions costs less than $1 and supports free customization, providing a feasible methodology for rapid nondestructive detection or monitoring of food quality.
Collapse
Affiliation(s)
- Jie Xia
- College of Engineering, China Agricultural University, Beijing 100083, China
| | - Wentao Huang
- College of Engineering, China Agricultural University, Beijing 100083, China
| | - Krisztina Majer-Baranyi
- Food Science Research Group, Institute of Food Science and Technology, Hungarian University of Agriculture and Life Sciences, Herman Ottó út 15, H-1022 Budapest, Hungary
| | - Mengjie Zhang
- College of Engineering, China Agricultural University, Beijing 100083, China
| | - Xiaoshuan Zhang
- College of Engineering, China Agricultural University, Beijing 100083, China
- Sanya Institute, China Agricultural University, Sanya 572024, China
| |
Collapse
|
31
|
Devi M, Wang H, Moon S, Sharma S, Strauss V. Laser-Carbonization - A Powerful Tool for Micro-Fabrication of Patterned Electronic Carbons. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2023; 35:e2211054. [PMID: 36841955 DOI: 10.1002/adma.202211054] [Citation(s) in RCA: 15] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/27/2022] [Revised: 02/06/2023] [Indexed: 06/18/2023]
Abstract
Fabricating electronic devices from natural, renewable resources is a common goal in engineering and materials science. In this regard, carbon is of special significance due to its biocompatibility combined with electrical conductivity and electrochemical stability. In microelectronics, however, carbon's device application is often inhibited by tedious and expensive preparation processes and a lack of control over processing and material parameters. Laser-assisted carbonization is emerging as a tool for the precise and selective synthesis of functional carbon-based materials for flexible device applications. In contrast to conventional carbonization via in-furnace pyrolysis, laser-carbonization is induced photo-thermally and occurs on the time-scale of milliseconds. By careful selection of the precursors and process parameters, the properties of this so-called laser-patterned carbon (LP-C) such as porosity, surface polarity, functional groups, degree of graphitization, charge-carrier structure, etc. can be tuned. In this critical review, a common perspective is generated on laser-carbonization in the context of general carbonization strategies, fundamentals of laser-induced materials processing, and flexible electronic applications, like electrodes for sensors, electrocatalysts, energy storage, or antennas. An attempt is made to have equal emphasis on material processing and application aspects such that this emerging technology can be optimally positioned in the broader context of carbon-based microfabrication.
Collapse
Affiliation(s)
- Mamta Devi
- School of Mechanical and Materials Engineering, Indian Institute of Technology Mandi, Kamand, Himachal Pradesh, 175075, India
| | - Huize Wang
- Department Kolloidchemie, Max-Planck-Institut für Kolloid- und Grenzflächenforschung, Am Mühlenberg 1, 14476, Potsdam, Germany
| | - Sanghwa Moon
- Department Kolloidchemie, Max-Planck-Institut für Kolloid- und Grenzflächenforschung, Am Mühlenberg 1, 14476, Potsdam, Germany
| | - Swati Sharma
- School of Mechanical and Materials Engineering, Indian Institute of Technology Mandi, Kamand, Himachal Pradesh, 175075, India
| | - Volker Strauss
- Department Kolloidchemie, Max-Planck-Institut für Kolloid- und Grenzflächenforschung, Am Mühlenberg 1, 14476, Potsdam, Germany
| |
Collapse
|
32
|
Zhu J, Tao J, Yan W, Song W. Pathways toward wearable and high-performance sensors based on hydrogels: toughening networks and conductive networks. Natl Sci Rev 2023; 10:nwad180. [PMID: 37565203 PMCID: PMC10411675 DOI: 10.1093/nsr/nwad180] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2023] [Revised: 05/02/2023] [Accepted: 06/21/2023] [Indexed: 08/12/2023] Open
Abstract
Wearable hydrogel sensors provide a user-friendly option for wearable electronics and align well with the existing manufacturing strategy for connecting and communicating with large numbers of Internet of Things devices. This is attributed to their components and structures, which exhibit exceptional adaptability, scalability, bio-compatibility, and self-healing properties, reminiscent of human skin. This review focuses on the recent research on principal structural elements of wearable hydrogels: toughening networks and conductive networks, highlighting the strategies for enhancing mechanical and electrical properties. Wearable hydrogel sensors are categorized for an extensive exploration of their composition, mechanism, and design approach. This review provides a comprehensive understanding of wearable hydrogels and offers guidance for the design of components and structures in order to develop high-performance wearable hydrogel sensors.
Collapse
Affiliation(s)
- Junbo Zhu
- Beijing Key Laboratory for Optical Materials and Photonic Devices, Department of Chemistry, Capital Normal University, Beijing 100048, China
| | - Jingchen Tao
- Beijing Key Laboratory for Optical Materials and Photonic Devices, Department of Chemistry, Capital Normal University, Beijing 100048, China
| | - Wei Yan
- Beijing Key Laboratory for Optical Materials and Photonic Devices, Department of Chemistry, Capital Normal University, Beijing 100048, China
| | - Weixing Song
- Beijing Key Laboratory for Optical Materials and Photonic Devices, Department of Chemistry, Capital Normal University, Beijing 100048, China
| |
Collapse
|
33
|
Garland NT, Schmieder J, Johnson ZT, Hjort RG, Chen B, Andersen C, Sanborn D, Kjeldgaard G, Pola CC, Li J, Gomes C, Smith EA, Angus H, Meyer J, Claussen JC. Wearable Flexible Perspiration Biosensors Using Laser-Induced Graphene and Polymeric Tape Microfluidics. ACS APPLIED MATERIALS & INTERFACES 2023; 15:38201-38213. [PMID: 37526921 DOI: 10.1021/acsami.3c04665] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/02/2023]
Abstract
Wearable biosensors promise real-time measurements of chemicals in human sweat, with the potential for dramatic improvements in medical diagnostics and athletic performance through continuous metabolite and electrolyte monitoring. However, sweat sensing is still in its infancy, and questions remain about whether sweat can be used for medical purposes. Wearable sensors are focused on proof-of-concept designs that are not scalable for multisubject trials, which could elucidate the utility of sweat sensing for health monitoring. Moreover, many wearable sensors do not include the microfluidics necessary to protect and channel consistent and clean sweat volumes to the sensor surface or are not designed to be disposable to prevent sensor biofouling and inaccuracies due to repeated use. Hence, there is a need to produce low-cost and single-use wearable sensors with integrated microfluidics to ensure reliable sweat sensing. Herein, we demonstrate the convergence of laser-induced graphene (LIG) based sensors with soft tape polymeric microfluidics to quantify both sweat metabolites (glucose and lactate) and electrolytes (sodium) for potential hydration and fatigue monitoring. Distinct LIG-electrodes were functionalized with glucose oxidase and lactate oxidase for selective sensing of glucose and lactate across physiological ranges found in sweat with sensitivities of 26.2 and 2.47 × 10-3 μA mM-1 cm-2, detection limits of 8 and 220 μM, and linear response ranges of 0-1 mM and 0-32 mM, respectively. LIG-electrodes functionalized with a sodium-ion-selective membrane displayed Nernstian sensitivity of 58.8 mV decade-1 and a linear response over the physiological range in sweat (10-100 mM). The sensors were tested in a simulated sweating skin microfluidic system and on-body during cycling tests in a multisubject trial. Results demonstrate the utility of LIG integrated with microfluidics for real-time, continuous measurements of biological analytes in sweat and help pave the way for the development of personalized wearable diagnostic tools.
Collapse
Affiliation(s)
- Nate T Garland
- Department of Mechanical Engineering, Iowa State University, Ames, Iowa 50011, United States
| | - Jacob Schmieder
- Department of Mechanical Engineering, Iowa State University, Ames, Iowa 50011, United States
| | - Zachary T Johnson
- Department of Mechanical Engineering, Iowa State University, Ames, Iowa 50011, United States
| | - Robert G Hjort
- Department of Mechanical Engineering, Iowa State University, Ames, Iowa 50011, United States
| | - Bolin Chen
- Department of Mechanical Engineering, Iowa State University, Ames, Iowa 50011, United States
| | - Cole Andersen
- Department of Mechanical Engineering, Iowa State University, Ames, Iowa 50011, United States
| | - Delaney Sanborn
- Department of Mechanical Engineering, Iowa State University, Ames, Iowa 50011, United States
| | - Gabriel Kjeldgaard
- Department of Mechanical Engineering, Iowa State University, Ames, Iowa 50011, United States
| | - Cicero C Pola
- Department of Mechanical Engineering, Iowa State University, Ames, Iowa 50011, United States
| | - Jingzhe Li
- Department of Chemistry, Iowa State University, Ames, Iowa 50011, United States
- The Ames Laboratory, U.S. Department of Energy, Ames, Iowa 50011, United States
| | - Carmen Gomes
- Department of Mechanical Engineering, Iowa State University, Ames, Iowa 50011, United States
| | - Emily A Smith
- Department of Chemistry, Iowa State University, Ames, Iowa 50011, United States
- The Ames Laboratory, U.S. Department of Energy, Ames, Iowa 50011, United States
| | - Hector Angus
- Department of Kinesiology, Iowa State University, Ames, Iowa 50011, United States
| | - Jacob Meyer
- Department of Kinesiology, Iowa State University, Ames, Iowa 50011, United States
| | - Jonathan C Claussen
- Department of Mechanical Engineering, Iowa State University, Ames, Iowa 50011, United States
| |
Collapse
|
34
|
Suriyaprakash J, Huang Y, Hu Z, Wang H, Zhan Y, Zhou Y, Thangavelu I, Wu L. Laser Scribing Turns Plastic Waste into a Biosensor via the Restructuration of Nanocarbon Composites for Noninvasive Dopamine Detection. BIOSENSORS 2023; 13:810. [PMID: 37622896 PMCID: PMC10452382 DOI: 10.3390/bios13080810] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/04/2023] [Revised: 08/08/2023] [Accepted: 08/10/2023] [Indexed: 08/26/2023]
Abstract
The development of affordable and compact noninvasive point-of-care (POC) dopamine biosensors for the next generation is currently a major and challenging problem. In this context, a highly sensitive, selective, and low-cost sensing probe is developed by a simple one-step laser-scribing process of plastic waste. A flexible POC device is developed as a prototype and shows a highly specific response to dopamine in the real sample (urine) as low as 100 pmol/L in a broad linear range of 10-10-10-4 mol/L. The 3D topological feature, carrier kinetics, and surface chemistry are found to improve with the formation of high-density metal-embedded graphene-foam composite driven by laser irradiation on the plastic-waste surface. The development of various kinds of flexible and tunable biosensors by plastic waste is now possible thanks to the success of this simple, but effective, laser-scribing technique, which is capable of modifying the matrix's electronic and chemical composition.
Collapse
Affiliation(s)
- Jagadeesh Suriyaprakash
- Guangdong Provincial Key Laboratory of Nanophotonic Functional Materials and Devices, School of Information and Optoelectronic Science and Engineering, South China Normal University, Guangzhou 510006, China; (J.S.); (Y.H.); (Z.H.); (H.W.); (Y.Z.)
| | - Yang Huang
- Guangdong Provincial Key Laboratory of Nanophotonic Functional Materials and Devices, School of Information and Optoelectronic Science and Engineering, South China Normal University, Guangzhou 510006, China; (J.S.); (Y.H.); (Z.H.); (H.W.); (Y.Z.)
| | - Zhifei Hu
- Guangdong Provincial Key Laboratory of Nanophotonic Functional Materials and Devices, School of Information and Optoelectronic Science and Engineering, South China Normal University, Guangzhou 510006, China; (J.S.); (Y.H.); (Z.H.); (H.W.); (Y.Z.)
| | - Hao Wang
- Guangdong Provincial Key Laboratory of Nanophotonic Functional Materials and Devices, School of Information and Optoelectronic Science and Engineering, South China Normal University, Guangzhou 510006, China; (J.S.); (Y.H.); (Z.H.); (H.W.); (Y.Z.)
| | - Yiyu Zhan
- Guangdong Provincial Key Laboratory of Nanophotonic Functional Materials and Devices, School of Information and Optoelectronic Science and Engineering, South China Normal University, Guangzhou 510006, China; (J.S.); (Y.H.); (Z.H.); (H.W.); (Y.Z.)
| | - Yangtao Zhou
- Shenyang National Laboratory for Materials Science, Institute of Metal Research, Chinese Academy of Sciences, Wenhua Road 72, Shenyang 110016, China;
| | - Indumathi Thangavelu
- Department of Chemistry, CHRIST (Deemed to be University), Bangalore 560029, Karnataka, India;
| | - Lijun Wu
- Guangdong Provincial Key Laboratory of Nanophotonic Functional Materials and Devices, School of Information and Optoelectronic Science and Engineering, South China Normal University, Guangzhou 510006, China; (J.S.); (Y.H.); (Z.H.); (H.W.); (Y.Z.)
| |
Collapse
|
35
|
Lee JS, Kim JW, Lee JH, Son YK, Kim YB, Woo K, Lee C, Kim ID, Seok JY, Yu JW, Park JH, Lee KJ. Flash-Induced High-Throughput Porous Graphene via Synergistic Photo-Effects for Electromagnetic Interference Shielding. NANO-MICRO LETTERS 2023; 15:191. [PMID: 37532956 PMCID: PMC10397175 DOI: 10.1007/s40820-023-01157-8] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/07/2023] [Accepted: 06/17/2023] [Indexed: 08/04/2023]
Abstract
Porous 2D materials with high conductivity and large surface area have been proposed for potential electromagnetic interference (EMI) shielding materials in future mobility and wearable applications to prevent signal noise, transmission inaccuracy, system malfunction, and health hazards. Here, we report on the synthesis of lightweight and flexible flash-induced porous graphene (FPG) with excellent EMI shielding performance. The broad spectrum of pulsed flashlight induces photo-chemical and photo-thermal reactions in polyimide films, forming 5 × 10 cm2-size porous graphene with a hollow pillar structure in a few milliseconds. The resulting material demonstrated low density (0.0354 g cm-3) and outstanding absolute EMI shielding effectiveness of 1.12 × 105 dB cm2 g-1. The FPG was characterized via thorough material analyses, and its mechanical durability and flexibility were confirmed by a bending cycle test. Finally, the FPG was utilized in drone and wearable applications, showing effective EMI shielding performance for internal/external EMI in a drone radar system and reducing the specific absorption rate in the human body.
Collapse
Affiliation(s)
- Jin Soo Lee
- Department of Materials Science and Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon, 34141, Republic of Korea
| | - Jeong-Wook Kim
- School of Electrical Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon, 34141, Republic of Korea
| | - Jae Hee Lee
- Department of Materials Science and Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon, 34141, Republic of Korea
| | - Yong Koo Son
- Department of Materials Science and Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon, 34141, Republic of Korea
| | - Young Bin Kim
- Department of Materials Science and Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon, 34141, Republic of Korea
| | - Kyoohee Woo
- Department of Printed Electronics, Nano-Convergence Manufacturing Systems Research Division, Korea Institute of Machinery and Materials (KIMM), 156 Gajeongbuk-Ro, Yuseong-Gu, Daejeon, 34103, Republic of Korea
| | - Chanhee Lee
- School of Electrical Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon, 34141, Republic of Korea
| | - Il-Doo Kim
- Department of Materials Science and Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon, 34141, Republic of Korea
| | - Jae Young Seok
- Department of Mechanical System Design Engineering, Seoul National University of Science and Technology, 232 Gongneung-ro, Nowon-gu, Seoul, 01811, Republic of Korea
| | - Jong Won Yu
- School of Electrical Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon, 34141, Republic of Korea
| | - Jung Hwan Park
- Department of Mechanical Engineering (Department of Aeronautics, Mechanical and Electronic Convergence Engineering), Kumoh National Institute of Technology, 61 Daehak-ro, Gumi, Gyeongbuk, 39177, Republic of Korea.
| | - Keon Jae Lee
- Department of Materials Science and Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon, 34141, Republic of Korea.
| |
Collapse
|
36
|
Qu C, Lu M, Zhang Z, Chen S, Liu D, Zhang D, Wang J, Sheng B. Flexible Microstructured Capacitive Pressure Sensors Using Laser Engraving and Graphitization from Natural Wood. Molecules 2023; 28:5339. [PMID: 37513212 PMCID: PMC10385064 DOI: 10.3390/molecules28145339] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2023] [Revised: 06/28/2023] [Accepted: 07/01/2023] [Indexed: 07/30/2023] Open
Abstract
In recent years, laser engraving has received widespread attention as a convenient, efficient, and programmable method which has enabled high-quality porous graphene to be obtained from various precursors. Laser engraving is often used to fabricate the dielectric layer with a microstructure for capacitive pressure sensors; however, the usual choice of electrodes remains poorly flexible metal electrodes, which greatly limit the overall flexibility of the sensors. In this work, we propose a flexible capacitive pressure sensor made entirely of thermoplastic polyurethane (TPU) and laser-induced graphene (LIG) derived from wood. The capacitive pressure sensor consisted of a flexible LIG/TPU electrode (LTE), an LIG/TPU electrode with a microhole array, and a dielectric layer of TPU with microcone array molded from a laser-engraved hole array on wood, which provided high sensitivity (0.11 kPa-1), an ultrawide pressure detection range (20 Pa to 1.4 MPa), a fast response (~300 ms), and good stability (>4000 cycles, at 0-35 kPa). We believe that our research makes a significant contribution to the literature, because the easy availability of the materials derived from wood and the overall consistent flexibility meet the requirements of flexible electronic devices.
Collapse
Affiliation(s)
- Chenkai Qu
- School of Optical Electrical and Computer Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China
- Shanghai Key Laboratory of Modern Optical Systems, Engineering Research Center of Optical Instruments and Systems, Shanghai 200093, China
| | - Meilan Lu
- School of Optical Electrical and Computer Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China
- Shanghai Key Laboratory of Modern Optical Systems, Engineering Research Center of Optical Instruments and Systems, Shanghai 200093, China
| | - Ziyan Zhang
- School of Optical Electrical and Computer Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China
- Shanghai Key Laboratory of Modern Optical Systems, Engineering Research Center of Optical Instruments and Systems, Shanghai 200093, China
| | - Shangbi Chen
- Inertial Technology Division, Shanghai Aerospace Control Technology Institute, Shanghai 201109, China
| | - Dewen Liu
- Inertial Technology Division, Shanghai Aerospace Control Technology Institute, Shanghai 201109, China
| | - Dawei Zhang
- School of Optical Electrical and Computer Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China
- Shanghai Key Laboratory of Modern Optical Systems, Engineering Research Center of Optical Instruments and Systems, Shanghai 200093, China
| | - Jing Wang
- Department of Ultrasound Medicine, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou 310006, China
| | - Bin Sheng
- School of Optical Electrical and Computer Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China
- Shanghai Key Laboratory of Modern Optical Systems, Engineering Research Center of Optical Instruments and Systems, Shanghai 200093, China
| |
Collapse
|
37
|
Yempally S, Kacem E, Ponnamma D. Influence of phase-separated structural morphologies on the piezo and triboelectric properties of polymer composites. DISCOVER NANO 2023; 18:93. [PMID: 37392317 DOI: 10.1186/s11671-023-03868-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/02/2023] [Accepted: 06/20/2023] [Indexed: 07/03/2023]
Abstract
Simplified and flexible fabrication methods, high output performance, and extreme flexibility of polymer-based nanocomposites represent versatile designs in self-powering devices for wearable electronics, sensors, and smart societies. Examples include polyvinylidene fluoride and its copolymers-based piezoelectric nanogenerators, green and recyclable triboelectric nanogenerators, etc. Advanced functionalities, multi-functional properties, and the extensive lifetime required for nanogenerators inspire researchers to focus on structural modifications of the polymeric materials, to fully exploit their performances. Phase separation is a physicochemical process in which polymeric phases rearrange, resulting in specific structures and properties, that ultimately influence mechanical, electronic, and other functional properties. This article will study the phase separation strategies used to modify the polymeric base, both physically and chemically, to generate the maximum electric power upon mechanical and frictional deformation. The effect of interfacial modification on the efficiency of the nanogenerators, chemical and mechanical stability, structural integrity, durable performance, and morphological appearance will be extensively covered in this review. Moreover, piezo- and triboelectric power generation have numerous challenges, such as poor resistance to mechanical deformation, reduced cyclic performance stability, and a high cost of production. These often depend on the method of developing the nanogenerators, and phase separation provides a unique advantage in reducing them. The current review provides a one-stop solution to understand and disseminate the phase separation process, types and mechanisms, advantages, and role in improving the piezoelectric and triboelectric performances of the nanogenerators.
Collapse
Affiliation(s)
- Swathi Yempally
- Center for Advanced Materials, Qatar University, P O Box 2713, Doha, Qatar
| | - Eya Kacem
- Materials Science and Technology Program, Department of Mathematics, Statistics and Physics, College of Arts and Sciences, Qatar University, 2713, Doha, Qatar
| | - Deepalekshmi Ponnamma
- Materials Science and Technology Program, Department of Mathematics, Statistics and Physics, College of Arts and Sciences, Qatar University, 2713, Doha, Qatar.
| |
Collapse
|
38
|
Xia HQ, Qiu D, Chen W, Mao G, Zeng J. In situ formed and fully integrated laser-induced graphene electrochemical chips for rapid and simultaneous determination of bioflavonoids in citrus fruits. Microchem J 2023. [DOI: 10.1016/j.microc.2023.108474] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
|
39
|
Salahandish R, Hyun JE, Haghayegh F, Tabrizi HO, Moossavi S, Khetani S, Ayala‐Charca G, Berenger BM, Niu YD, Ghafar‐Zadeh E, Nezhad AS. CoVSense: Ultrasensitive Nucleocapsid Antigen Immunosensor for Rapid Clinical Detection of Wildtype and Variant SARS-CoV-2. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2023; 10:e2206615. [PMID: 36995043 PMCID: PMC10214237 DOI: 10.1002/advs.202206615] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/11/2022] [Revised: 01/31/2023] [Indexed: 05/27/2023]
Abstract
The widespread accessibility of commercial/clinically-viable electrochemical diagnostic systems for rapid quantification of viral proteins demands translational/preclinical investigations. Here, Covid-Sense (CoVSense) antigen testing platform; an all-in-one electrochemical nano-immunosensor for sample-to-result, self-validated, and accurate quantification of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) nucleocapsid (N)-proteins in clinical examinations is developed. The platform's sensing strips benefit from a highly-sensitive, nanostructured surface, created through the incorporation of carboxyl-functionalized graphene nanosheets, and poly(3,4-ethylenedioxythiophene) polystyrene sulfonate (PEDOT:PSS) conductive polymers, enhancing the overall conductivity of the system. The nanoengineered surface chemistry allows for compatible direct assembly of bioreceptor molecules. CoVSense offers an inexpensive (<$2 kit) and fast/digital response (<10 min), measured using a customized hand-held reader (<$25), enabling data-driven outbreak management. The sensor shows 95% clinical sensitivity and 100% specificity (Ct<25), and overall sensitivity of 91% for combined symptomatic/asymptomatic cohort with wildtype SARS-CoV-2 or B.1.1.7 variant (N = 105, nasal/throat samples). The sensor correlates the N-protein levels to viral load, detecting high Ct values of ≈35, with no sample preparation steps, while outperforming the commercial rapid antigen tests. The current translational technology fills the gap in the workflow of rapid, point-of-care, and accurate diagnosis of COVID-19.
Collapse
Affiliation(s)
- Razieh Salahandish
- BioMEMS and Bioinspired Microfluidic LaboratoryDepartment of Biomedical EngineeringUniversity of CalgaryCalgaryABT2N 1N4Canada
- Department of Mechanical and Manufacturing EngineeringUniversity of CalgaryCalgaryABT2N 1N4Canada
- Laboratory of Advanced Biotechnologies for Health Assessments (LAB‐HA)Department of Electrical Engineering and Computer ScienceLassonde School of EngineeringYork UniversityTorontoM3J 1P3Canada
| | - Jae Eun Hyun
- Department of Ecosystem and Public HealthFaculty of Veterinary MedicineUniversity of CalgaryCalgaryABT2N 1N4Canada
| | - Fatemeh Haghayegh
- BioMEMS and Bioinspired Microfluidic LaboratoryDepartment of Biomedical EngineeringUniversity of CalgaryCalgaryABT2N 1N4Canada
- Department of Mechanical and Manufacturing EngineeringUniversity of CalgaryCalgaryABT2N 1N4Canada
| | - Hamed Osouli Tabrizi
- Biologically Inspired Sensors and Actuators (BioSA)Department of Electrical Engineering and Computer ScienceLassonde School of EngineeringYork UniversityTorontoM3J 1P3Canada
| | - Shirin Moossavi
- BioMEMS and Bioinspired Microfluidic LaboratoryDepartment of Biomedical EngineeringUniversity of CalgaryCalgaryABT2N 1N4Canada
- Department of Physiology and PharmacologyUniversity of CalgaryCalgaryABT2N 1N4Canada
- International Microbiome CentreCumming School of MedicineHealth Sciences CentreUniversity of CalgaryCalgaryABT2N 1N4Canada
| | - Sultan Khetani
- BioMEMS and Bioinspired Microfluidic LaboratoryDepartment of Biomedical EngineeringUniversity of CalgaryCalgaryABT2N 1N4Canada
| | - Giancarlo Ayala‐Charca
- Biologically Inspired Sensors and Actuators (BioSA)Department of Electrical Engineering and Computer ScienceLassonde School of EngineeringYork UniversityTorontoM3J 1P3Canada
| | - Byron M. Berenger
- Alberta Public Health LaboratoryAlberta Precision Laboratories3330 Hospital DriveCalgaryABT2N 4W4Canada
- Department of Pathology and Laboratory MedicineFaculty of MedicineUniversity of CalgaryCalgaryABT2N 1N4Canada
| | - Yan Dong Niu
- Department of Ecosystem and Public HealthFaculty of Veterinary MedicineUniversity of CalgaryCalgaryABT2N 1N4Canada
| | - Ebrahim Ghafar‐Zadeh
- Biologically Inspired Sensors and Actuators (BioSA)Department of Electrical Engineering and Computer ScienceLassonde School of EngineeringYork UniversityTorontoM3J 1P3Canada
| | - Amir Sanati Nezhad
- BioMEMS and Bioinspired Microfluidic LaboratoryDepartment of Biomedical EngineeringUniversity of CalgaryCalgaryABT2N 1N4Canada
- Department of Mechanical and Manufacturing EngineeringUniversity of CalgaryCalgaryABT2N 1N4Canada
- Biomedical Engineering Graduate ProgramUniversity of CalgaryCalgaryABT2N 1N4Canada
| |
Collapse
|
40
|
Yang L, Yan J, Meng C, Dutta A, Chen X, Xue Y, Niu G, Wang Y, Du S, Zhou P, Zhang C, Guo S, Cheng H. Vanadium Oxide-Doped Laser-Induced Graphene Multi-Parameter Sensor to Decouple Soil Nitrogen Loss and Temperature. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2023; 35:e2210322. [PMID: 36656071 PMCID: PMC10427720 DOI: 10.1002/adma.202210322] [Citation(s) in RCA: 15] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/07/2022] [Revised: 12/27/2022] [Indexed: 06/17/2023]
Abstract
Monitoring nitrogen utilization efficiency and soil temperature in agricultural systems for timely intervention is essential for crop health with reduced environmental pollution. Herein, this work presents a high-performance multi-parameter sensor based on vanadium oxide (VOX )-doped laser-induced graphene (LIG) foam to completely decouple nitrogen oxides (NOX ) and temperature. The highly porous 3D VOX -doped LIG foam composite is readily obtained by laser scribing vanadium sulfide (V5 S8 )-doped block copolymer and phenolic resin self-assembled films. The heterojunction formed at the LIG/VOX interface provides the sensor with enhanced response to NOX and an ultralow limit of detection of 3 ppb (theoretical estimate of 451 ppt) at room temperature. The sensor also exhibits a wide detection range, fast response/recovery, good selectivity, and stability over 16 days. Meanwhile, the sensor can accurately detect temperature over a wide linear range of 10-110 °C. The encapsulation of the sensor with a soft membrane further allows for temperature sensing without being affected by NOX . The unencapsulated sensor operated at elevated temperature removes the influences of relative humidity and temperature variations for accurate NOX measurements. The capability to decouple nitrogen loss and soil temperature paves the way for the development of future multimodal decoupled electronics for precision agriculture and health monitoring.
Collapse
Affiliation(s)
- Li Yang
- State Key Laboratory of Reliability and Intelligence of Electrical Equipment, School of Health Sciences and Biomedical Engineering, Hebei University of Technology, Tianjin, 300130, China
| | - Jiayi Yan
- State Key Laboratory for Reliability and Intelligence of Electrical Equipment, Hebei Key Laboratory of Smart Sensing and Human-Robot Interaction, School of Mechanical Engineering, Hebei University of Technology, Tianjin, 300130, China
| | - Chuizhou Meng
- State Key Laboratory for Reliability and Intelligence of Electrical Equipment, Hebei Key Laboratory of Smart Sensing and Human-Robot Interaction, School of Mechanical Engineering, Hebei University of Technology, Tianjin, 300130, China
| | - Ankan Dutta
- Department of Engineering Science and Mechanics, The Pennsylvania State University, University Park, 16802, USA
| | - Xue Chen
- State Key Laboratory of Reliability and Intelligence of Electrical Equipment, Key Laboratory of Bioelectromagnetics and Neuroengineering of Hebei Province, School of Electrical Engineering, Hebei University of Technology, Tianjin, 300130, China
| | - Ye Xue
- State Key Laboratory of Reliability and Intelligence of Electrical Equipment, School of Health Sciences and Biomedical Engineering, Hebei University of Technology, Tianjin, 300130, China
| | - Guangyu Niu
- School of Architecture and Art, Hebei University of Technology, Tianjin, 300130, China
| | - Ya Wang
- State Key Laboratory for Reliability and Intelligence of Electrical Equipment, Hebei Key Laboratory of Smart Sensing and Human-Robot Interaction, School of Mechanical Engineering, Hebei University of Technology, Tianjin, 300130, China
| | - Shuaijie Du
- State Key Laboratory of Reliability and Intelligence of Electrical Equipment, Key Laboratory of Bioelectromagnetics and Neuroengineering of Hebei Province, School of Electrical Engineering, Hebei University of Technology, Tianjin, 300130, China
| | - Peng Zhou
- Tianjin Tianzhong Yimai Technology Development Co., Ltd, Tianjin, 300384, China
| | - Cheng Zhang
- Fujian Key Laboratory of Functional Marine Sensing Materials, College of Material and Chemical Engineering, Minjiang University, Fuzhou, 350108, China
| | - Shijie Guo
- State Key Laboratory for Reliability and Intelligence of Electrical Equipment, Hebei Key Laboratory of Smart Sensing and Human-Robot Interaction, School of Mechanical Engineering, Hebei University of Technology, Tianjin, 300130, China
| | - Huanyu Cheng
- Department of Engineering Science and Mechanics, The Pennsylvania State University, University Park, 16802, USA
| |
Collapse
|
41
|
Brooker C, Tronci G. A collagen-based theranostic wound dressing with visual, long-lasting infection detection capability. Int J Biol Macromol 2023; 236:123866. [PMID: 36870632 DOI: 10.1016/j.ijbiomac.2023.123866] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2022] [Revised: 02/07/2023] [Accepted: 02/24/2023] [Indexed: 03/06/2023]
Abstract
Continuous wound monitoring is one strategy to minimise infection severity and inform prompt variations in therapeutic care following infection diagnosis. However, integration of this functionality in therapeutic wound dressings is still challenging. We hypothesised that a theranostic dressing could be realised by integrating a collagen-based wound contact layer with previously demonstrated wound healing capability, and a halochromic dye, i.e. bromothymol blue (BTB), undergoing colour change following infection-associated pH changes (pH: 5-6 ➔ >7). Two different BTB integration strategies, i.e. electrospinning and drop-casting, were pursued to introduce long-lasting visual infection detection capability through retention of BTB within the dressing. Both systems had an average BTB loading efficiency of 99 wt% and displayed a colour change within 1 min of contact with simulated wound fluid. Drop-cast samples retained up to 85 wt% of BTB after 96 h in a near-infected wound environment, in contrast to the fibre-bearing prototypes, which released over 80 wt% of BTB over the same time period. An increase in collagen denaturation temperature (DSC) and red shifts (ATR-FTIR) suggest the formation of secondary interactions between the collagen-based hydrogel and the BTB, which are attributed to count for the long-lasting dye confinement and durable dressing colour change. Given the high L929 fibroblast viability in drop-cast sample extracts (92 %, 7 days), the presented multiscale design is simple, cell- and regulatory-friendly, and compliant with industrial scale-up. This design, therefore, offers a new platform for the development of theranostic dressings enabling accelerated wound healing and prompt infection diagnosis.
Collapse
Affiliation(s)
- Charles Brooker
- Clothworkers' Centre for Textile Materials Innovation for Healthcare (CCTMIH), School of Design, University of Leeds, Leeds LS2 9JT, United Kingdom; School of Dentistry, St. James's University Hospital, University of Leeds, Leeds LS9 7TF, United Kingdom
| | - Giuseppe Tronci
- Clothworkers' Centre for Textile Materials Innovation for Healthcare (CCTMIH), School of Design, University of Leeds, Leeds LS2 9JT, United Kingdom; School of Dentistry, St. James's University Hospital, University of Leeds, Leeds LS9 7TF, United Kingdom.
| |
Collapse
|
42
|
Ye X, Qi M, Qiang H, Chen M, Zheng X, Gu M, Zhao X, Yang Y, He C, Zhang J. Laser-ablated violet phosphorus/graphene heterojunction as ultrasensitive ppb-level room-temperature NO sensor. CHINESE CHEM LETT 2023. [DOI: 10.1016/j.cclet.2023.108199] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/12/2023]
|
43
|
Aparicio-Martínez EP, Vega-Rios A, Osuna V, Dominguez RB. Salivary Glucose Detection with Laser Induced Graphene/AgNPs Non-Enzymatic Sensor. BIOSENSORS 2023; 13:207. [PMID: 36831974 PMCID: PMC9954126 DOI: 10.3390/bios13020207] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/26/2022] [Revised: 01/23/2023] [Accepted: 01/24/2023] [Indexed: 06/18/2023]
Abstract
The tailoring of novel nanomaterials for sensitive glucose detection through a non-enzymatic mechanism is currently under intensive research. Here, we present a laser-induced graphene (LIG) electrode decorated with silver nanoparticles (AgNPs) as a catalytic element for the direct electrooxidation of glucose. The AgNPs were synthesized through cyclic voltammetry using LIG as a template, resulting in a porous tridimensional assembly with anchored nanostructures. The characterization corroborated the formation of LIG/AgNPs composite with distinctive peaks attributed to Ag2O and AgO interaction with glucose. The proposed non-enzymatic sensors were successfully applied for non-enzymatic amperometric detection, exhibiting a linear range from 1 to 10 mM in the first peak (+0.7 V) and a narrow range from 1 to 2 mM with higher sensitivity of 52.2 mA/mM and improved LOD of 45 μM in the second peak (+0.55 V). The applicability of the LIG/AgNPs sensor was evaluated with spiked artificial saliva in a PoC format using a smartphone potentiostat, showing an average recovery rate of 91%. The analysis was performed in a portable, mobile, and low-cost fashion using a simulated non-invasive sample, with promising results in clinical ranges.
Collapse
Affiliation(s)
- Eider Pedro Aparicio-Martínez
- Centro de Investigación en Materiales Avanzados, SC, Miguel de Cervantes #120, Complejo Industrial Chihuahua, Chihuahua 31136, Mexico
| | - Alejandro Vega-Rios
- Centro de Investigación en Materiales Avanzados, SC, Miguel de Cervantes #120, Complejo Industrial Chihuahua, Chihuahua 31136, Mexico
| | - Velia Osuna
- CONACyT-CIMAV, SC, Miguel de Cervantes #120, Complejo Industrial Chihuahua, Chihuahua 31136, Mexico
| | - Rocio Berenice Dominguez
- CONACyT-CIMAV, SC, Miguel de Cervantes #120, Complejo Industrial Chihuahua, Chihuahua 31136, Mexico
| |
Collapse
|
44
|
Hu L, Cui J, Wang Y, Jia J. An ultrasensitive electrochemical biosensor for bisphenol A based on aptamer-modified MrGO@AuNPs and ssDNA-functionalized AuNP@MBs synergistic amplification. CHEMOSPHERE 2023; 311:137154. [PMID: 36351468 DOI: 10.1016/j.chemosphere.2022.137154] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/18/2022] [Revised: 10/30/2022] [Accepted: 11/03/2022] [Indexed: 06/16/2023]
Abstract
Bisphenol A (BPA) is a harmful endocrine disruptor, sensitive and rapid quantification of BPA is highly desirable. In this work, a novel synergistic signal-amplifying electrochemical biosensor was developed for BPA detection by using a recognition probe (RP) constructed by BPA aptamer modified gold nanoparticles-loaded magnetic reduced graphene oxide (Aptamer-MrGO@AuNPs), and a signal probe (SP) constructed by BPA aptamer-complementary single-stranded DNA (ssDNA) functionalized methylene blue (MB)-loaded gold nanoparticle (ssDNA-AuNP@MBs). The RP and SP can self-assemble to form a stable RP-SP complex through complementary base pairing. The current intensity of the biosensor correlates with the number of RP-SP complexes. In the presence of BPA, the BPA aptamer can capture BPA with high selectivity and affinity, form an RP-BPA complex and dissociate the RP-SP complex to release SP, resulting in a decrease in the current signal intensity of the biosensor. A single AuNP could be loaded with multiple BPA aptamers and MBs, which improves the recognition efficiency and enhances the signal intensity. Due to the magnetic properties of MrGO@AuNPs, the magnetic separation and adsorption of RP or RP-SP complex is very convenient, enabling all reaction processes to be carried out in solution, which not only improves the mass transfer efficiency, but also simplifies the operation. Under optimal conditions, the developed biosensor had a detection limit as low as 0.141 pg/mL and had been successfully applied to the detection of real environmental water samples. Therefore, the synergistic signal amplification strategy of RP and SP has potential value in the detection of trace pollutants in the water environment.
Collapse
Affiliation(s)
- Liuyin Hu
- School of Environmental Science and Engineering, Shanghai Jiao Tong University, No. 800, Dongchuan Road, Shanghai, 200240, PR China
| | - Jiahua Cui
- School of Chemistry and Chemical Engineering, Shanghai Jiao Tong University, No. 800, Dongchuan Road, Shanghai, 200240, PR China
| | - Yalin Wang
- School of Environmental Science and Engineering, Shanghai Jiao Tong University, No. 800, Dongchuan Road, Shanghai, 200240, PR China
| | - Jinping Jia
- School of Environmental Science and Engineering, Shanghai Jiao Tong University, No. 800, Dongchuan Road, Shanghai, 200240, PR China; School of Chemistry and Chemical Engineering, Shanghai Jiao Tong University, No. 800, Dongchuan Road, Shanghai, 200240, PR China.
| |
Collapse
|
45
|
Ma T, Zhang J, Zhang L, Zhang Q, Xu X, Xiong Y, Ying Y, Fu Y. Recent advances in determination applications of emerging films based on nanomaterials. Adv Colloid Interface Sci 2023; 311:102828. [PMID: 36587470 DOI: 10.1016/j.cis.2022.102828] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2022] [Revised: 12/12/2022] [Accepted: 12/22/2022] [Indexed: 12/28/2022]
Abstract
Sensitive and facile detection of analytes is crucial in various fields such as agriculture production, food safety, clinical diagnosis and therapy, and environmental monitoring. However, the synergy of complicated sample pretreatment and detection is an urgent challenge. By integrating the inherent porosity, processability and flexibility of films and the diversified merits of nanomaterials, nanomaterial-based films have evolved as preferred candidates to meet the above challenge. Recent years have witnessed the flourishment of films-based detection technologies due to their unique porous structures and integrated physical/chemical merits, which favors the separation/collection and detection of analytes in a rapid, efficient and facile way. In particular, films based on nanomaterials consisting of 0D metal-organic framework particles, 1D nanofibers and carbon nanotubes, and 2D graphene and analogs have drawn increasing attention due to incorporating new properties from nanomaterials. This paper summarizes the progress of the fabrication of emerging films based on nanomaterials and their detection applications in recent five years, focusing on typical electrochemical and optical methods. Some new interesting applications, such as point-of-care testing, wearable devices and detection chips, are proposed and emphasized. This review will provide insights into the integration and processability of films based on nanomaterials, thus stimulate further contributions towards films based on nanomaterials for high-performance analytical-chemistry-related applications.
Collapse
Affiliation(s)
- Tongtong Ma
- College of Biosystems Engineering and Food Science, Key Laboratory of Intelligent Equipment and Robotics for Agriculture of Zhejiang Province, Zhejiang University, Hangzhou 310058, China
| | - Jie Zhang
- College of Biosystems Engineering and Food Science, Key Laboratory of Intelligent Equipment and Robotics for Agriculture of Zhejiang Province, Zhejiang University, Hangzhou 310058, China
| | - Lin Zhang
- College of Biosystems Engineering and Food Science, Key Laboratory of Intelligent Equipment and Robotics for Agriculture of Zhejiang Province, Zhejiang University, Hangzhou 310058, China
| | - Qi Zhang
- College of Biosystems Engineering and Food Science, Key Laboratory of Intelligent Equipment and Robotics for Agriculture of Zhejiang Province, Zhejiang University, Hangzhou 310058, China
| | - Xiahong Xu
- State Key Laboratory for Managing Biotic and Chemical Threats to the Quality and Safety of Agro-products, Institute of Agro-product Safety and Nutrition, Zhejiang Academy of Agricultural Sciences, Hangzhou 310021, China.
| | - Yonghua Xiong
- State Key Laboratory of Food Science and Technology, School of Food Science and Technology, Nanchang University, Nanchang 330047, China
| | - Yibin Ying
- College of Biosystems Engineering and Food Science, Key Laboratory of Intelligent Equipment and Robotics for Agriculture of Zhejiang Province, Zhejiang University, Hangzhou 310058, China
| | - Yingchun Fu
- College of Biosystems Engineering and Food Science, Key Laboratory of Intelligent Equipment and Robotics for Agriculture of Zhejiang Province, Zhejiang University, Hangzhou 310058, China.
| |
Collapse
|
46
|
Lu XL, Shao JC, Chi HZ, Zhang W, Qin H. Self-Assembly of a Graphene Oxide Liquid Crystal for Water Treatment. ACS APPLIED MATERIALS & INTERFACES 2022; 14:47549-47559. [PMID: 36219449 DOI: 10.1021/acsami.2c11290] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
Abstract
Adsorbents, especially those with high removal efficiency, long life, and multi-purpose capabilities, are the most crucial components in an adsorption system. By taking advantage of the liquid-like mobility and crystal-like ordering of liquid crystal materials, a liquid crystal induction method is developed and applied to construct three-dimensional graphene-based adsorbents featuring excellent shape adaptability, a distinctive pore structure, and abundant surface functional groups. When the monoliths are used for water restoration, the large amount of residual oxygen-containing groups is more susceptible to electrophilic attack, thus contributing to cation adsorption (up to 705.4 mg g-1 for methylene blue), while the connected microvoids between the aligned graphene oxide sheets facilitate mass transfer, e.g., the high adsorption capacity for organic pollutants (196.2 g g-1 for ethylene glycol) and the high evaporation rate for water (4.01 kg m-2 h-1). This work gives a practical method for producing high-performance graphene-based functional materials for those applications that are sensitive to surface and mass transfer properties.
Collapse
Affiliation(s)
- Xin Liang Lu
- College of Materials and Environmental Engineering, Hangzhou Dianzi University, Hangzhou 310018, People's Republic of China
| | - Jia Cheng Shao
- College of Materials and Environmental Engineering, Hangzhou Dianzi University, Hangzhou 310018, People's Republic of China
| | - Hong Zhong Chi
- College of Materials and Environmental Engineering, Hangzhou Dianzi University, Hangzhou 310018, People's Republic of China
| | - Wen Zhang
- College of Materials and Environmental Engineering, Hangzhou Dianzi University, Hangzhou 310018, People's Republic of China
| | - Haiying Qin
- College of Materials and Environmental Engineering, Hangzhou Dianzi University, Hangzhou 310018, People's Republic of China
| |
Collapse
|
47
|
Rodriguez RD, Fatkullin M, Garcia A, Petrov I, Averkiev A, Lipovka A, Lu L, Shchadenko S, Wang R, Sun J, Li Q, Jia X, Cheng C, Kanoun O, Sheremet E. Laser-Engineered Multifunctional Graphene-Glass Electronics. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2022; 34:e2206877. [PMID: 36038983 DOI: 10.1002/adma.202206877] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/28/2022] [Revised: 08/25/2022] [Indexed: 06/15/2023]
Abstract
Glass electronics inspire the emergence of smart functional surfaces. To evolve this concept to the next level, developing new strategies for scalable, inexpensive, and electrically conductive glass-based robust nanocomposites is crucial. Graphene is an attractive material as a conductive filler; however, integrating it firmly into a glass with no energy-intensive sintering, melting, or harsh chemicals has not been possible until now. Moreover, these methods have very limited capability for fabricating robust patterns for electronic circuits. In this work, a conductive (160 OΩ sq-1 ) and resilient nanocomposite between glass and graphene is achieved via single-step laser-induced backward transfer (LIBT). Beyond conventional LIBT involving mass transfer, this approach simultaneously drives chemical transformations in glass including silicon compound formation and graphene oxide (GO) reduction. These processes take place together with the generation and transfer of the highest-quality laser-reduced GO (rGO) reported to date (Raman intensity ratio ID /IG = 0.31) and its integration into the glass. The rGO-LIBT nanocomposite is further functionalized with silver to achieve a highly sensitive (10-9 m) dual-channel plasmonic optical and electrochemical sensor. Besides the electrical circuit demonstration, an electrothermal heater is fabricated that reaches temperatures above 300 °C and continuously operates for over 48 h.
Collapse
Affiliation(s)
- Raul D Rodriguez
- Tomsk Polytechnic University, Lenin ave. 30, Tomsk, 634050, Russia
| | - Maxim Fatkullin
- Tomsk Polytechnic University, Lenin ave. 30, Tomsk, 634050, Russia
| | - Aura Garcia
- Tomsk Polytechnic University, Lenin ave. 30, Tomsk, 634050, Russia
| | - Ilia Petrov
- Tomsk Polytechnic University, Lenin ave. 30, Tomsk, 634050, Russia
| | - Andrey Averkiev
- Tomsk Polytechnic University, Lenin ave. 30, Tomsk, 634050, Russia
| | - Anna Lipovka
- Tomsk Polytechnic University, Lenin ave. 30, Tomsk, 634050, Russia
| | - Liliang Lu
- School of Chemistry and Chemical Engineering/Key Laboratory for Green Processing of Chemical Engineering of Xinjiang Bingtuan, Key Laboratory of Materials-Oriented Chemical Engineering of Xinjiang Uygur Autonomous Region, Engineering Research Center of Materials-Oriented Chemical Engineering of Xinjiang Bingtuan, Shihezi University, Shihezi, 832003, P. R. China
| | | | - Ranran Wang
- The State Key Lab of High Performance Ceramics and Superfine Microstructure, Shanghai Institute of Ceramics, Chinese Academy of Sciences, Shanghai, 200050, China
| | - Jing Sun
- The State Key Lab of High Performance Ceramics and Superfine Microstructure, Shanghai Institute of Ceramics, Chinese Academy of Sciences, Shanghai, 200050, China
| | - Qiu Li
- College of Polymer Science and Engineering, State Key Laboratory of Polymer Materials Engineering, Sichuan University, Chengdu, 610065, China
| | - Xin Jia
- School of Chemistry and Chemical Engineering/Key Laboratory for Green Processing of Chemical Engineering of Xinjiang Bingtuan, Key Laboratory of Materials-Oriented Chemical Engineering of Xinjiang Uygur Autonomous Region, Engineering Research Center of Materials-Oriented Chemical Engineering of Xinjiang Bingtuan, Shihezi University, Shihezi, 832003, P. R. China
| | - Chong Cheng
- College of Polymer Science and Engineering, State Key Laboratory of Polymer Materials Engineering, Sichuan University, Chengdu, 610065, China
| | - Olfa Kanoun
- Professorship Measurement and Sensor Technology, Chemnitz University of Technology, 09111, Chemnitz, Germany
| | | |
Collapse
|
48
|
Zhou K, Kammarchedu V, Butler D, Soltan Khamsi P, Ebrahimi A. Electrochemical Sensors Based on MoS x -Functionalized Laser-Induced Graphene for Real-Time Monitoring of Phenazines Produced by Pseudomonas aeruginosa. Adv Healthc Mater 2022; 11:e2200773. [PMID: 35853169 PMCID: PMC9547893 DOI: 10.1002/adhm.202200773] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2022] [Revised: 06/21/2022] [Indexed: 01/27/2023]
Abstract
Pseudomonas aeruginosa (P. aeruginosa) is an opportunistic pathogen causing infections in blood and implanted devices. Traditional identification methods take more than 24 h to produce results. Molecular biology methods expedite detection, but require an advanced skill set. To address these challenges, this work demonstrates functionalization of laser-induced graphene (LIG) for developing flexible electrochemical sensors for P. aeruginosa based on phenazines. Electrodeposition as a facile approach is used to functionalize LIG with molybdenum polysulfide (MoSx ). The sensor's limit of detection (LOD), sensitivity, and specificity are determined in broth, agar, and wound simulating medium (WSM). Control experiments with Escherichia coli, which does not produce phenazines, demonstrate specificity of sensors for P. aeruginosa. The LOD for pyocyanin (PYO) and phenazine-1-carboxylic acid (PCA) is 0.19 × 10-6 and 1.2 × 10-6 m, respectively. Furthermore, the highly stable sensors enable real-time monitoring of P. aeruginosa biofilms over several days. Comparing square wave voltammetry data over time shows time-dependent generation of phenazines. In particular, two configurations-"Normal" and "Flipped"-are studied, showing that the phenazines time dynamics vary depending on how cells interact with sensors. The reported results demonstrate the potential of the developed sensors for integration with wound dressings for early diagnosis of P. aeruginosa infection.
Collapse
Affiliation(s)
- Keren Zhou
- School of Electrical Engineering and Computer Science, The Pennsylvania State University, University Park, PA 16802, USA
- Materials Research Institute, The Pennsylvania State University, University Park, PA 16802, USA
| | - Vinay Kammarchedu
- School of Electrical Engineering and Computer Science, The Pennsylvania State University, University Park, PA 16802, USA
- Materials Research Institute, The Pennsylvania State University, University Park, PA 16802, USA
| | - Derrick Butler
- School of Electrical Engineering and Computer Science, The Pennsylvania State University, University Park, PA 16802, USA
- Materials Research Institute, The Pennsylvania State University, University Park, PA 16802, USA
| | - Pouya Soltan Khamsi
- School of Electrical Engineering and Computer Science, The Pennsylvania State University, University Park, PA 16802, USA
- Materials Research Institute, The Pennsylvania State University, University Park, PA 16802, USA
| | - Aida Ebrahimi
- School of Electrical Engineering and Computer Science, The Pennsylvania State University, University Park, PA 16802, USA
- Materials Research Institute, The Pennsylvania State University, University Park, PA 16802, USA
- Department of Biomedical Engineering, The Pennsylvania State University, University Park, PA 16802, USA
| |
Collapse
|
49
|
Ullah H, Wahab MA, Will G, Karim MR, Pan T, Gao M, Lai D, Lin Y, Miraz MH. Recent Advances in Stretchable and Wearable Capacitive Electrophysiological Sensors for Long-Term Health Monitoring. BIOSENSORS 2022; 12:bios12080630. [PMID: 36005025 PMCID: PMC9406032 DOI: 10.3390/bios12080630] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/23/2022] [Revised: 07/22/2022] [Accepted: 07/27/2022] [Indexed: 05/27/2023]
Abstract
Over the past several years, wearable electrophysiological sensors with stretchability have received significant research attention because of their capability to continuously monitor electrophysiological signals from the human body with minimal body motion artifacts, long-term tracking, and comfort for real-time health monitoring. Among the four different sensors, i.e., piezoresistive, piezoelectric, iontronic, and capacitive, capacitive sensors are the most advantageous owing to their reusability, high durability, device sterilization ability, and minimum leakage currents between the electrode and the body to reduce the health risk arising from any short circuit. This review focuses on the development of wearable, flexible capacitive sensors for monitoring electrophysiological conditions, including the electrode materials and configuration, the sensing mechanisms, and the fabrication strategies. In addition, several design strategies of flexible/stretchable electrodes, body-to-electrode signal transduction, and measurements have been critically evaluated. We have also highlighted the gaps and opportunities needed for enhancing the suitability and practical applicability of wearable capacitive sensors. Finally, the potential applications, research challenges, and future research directions on stretchable and wearable capacitive sensors are outlined in this review.
Collapse
Affiliation(s)
- Hadaate Ullah
- School of Materials and Energy, University of Electronic Science and Technology of China, Chengdu 610054, China
- State Key Laboratory of Electronic Thin Films and Integrated Devices, University of Electronic Science and Technology of China, Chengdu 610054, China
| | - Md A. Wahab
- Institute for Advanced Study, Chengdu University, Chengdu 610106, China
- School of Mechanical, Medical and Process Engineering, Faculty of Engineering, Queensland University of Technology, George St Brisbane, GPO Box 2434, Brisbane, QLD 4001, Australia
| | - Geoffrey Will
- School of Mechanical, Medical and Process Engineering, Faculty of Engineering, Queensland University of Technology, George St Brisbane, GPO Box 2434, Brisbane, QLD 4001, Australia
| | - Mohammad R. Karim
- Center of Excellence for Research in Engineering Materials (CEREM), Deanship of Scientific Research (DSR), King Saud University, Riyadh 11421, Saudi Arabia
- K.A. CARE Energy Research and Innovation Center, Riyadh 11451, Saudi Arabia
| | - Taisong Pan
- School of Materials and Energy, University of Electronic Science and Technology of China, Chengdu 610054, China
- State Key Laboratory of Electronic Thin Films and Integrated Devices, University of Electronic Science and Technology of China, Chengdu 610054, China
| | - Min Gao
- School of Materials and Energy, University of Electronic Science and Technology of China, Chengdu 610054, China
- State Key Laboratory of Electronic Thin Films and Integrated Devices, University of Electronic Science and Technology of China, Chengdu 610054, China
| | - Dakun Lai
- Biomedical Imaging and Electrophysiology Laboratory, School of Electronic Science and Engineering, University of Electronic Science and Technology of China, Chengdu 610054, China
| | - Yuan Lin
- School of Materials and Energy, University of Electronic Science and Technology of China, Chengdu 610054, China
- State Key Laboratory of Electronic Thin Films and Integrated Devices, University of Electronic Science and Technology of China, Chengdu 610054, China
- Medico-Engineering Corporation on Applied Medicine Research Center, University of Electronic Science and Technology of China, Chengdu 610054, China
| | - Mahdi H. Miraz
- School of Computing and Data Science, Xiamen University Malaysia, Bandar Sunsuria, Sepang 43900, Malaysia
- School of Computing, Faculty of Arts, Science and Technology, Wrexham Glyndŵr University, Wrexham LL112AW, UK
| |
Collapse
|
50
|
Shandilya R, Bhargava A, Ratre P, Kumari R, Tiwari R, Chauhan P, Mishra PK. Graphene Quantum-Dot-Based Nanophotonic Approach for Targeted Detection of Long Noncoding RNAs in Circulation. ACS OMEGA 2022; 7:26601-26609. [PMID: 35936471 PMCID: PMC9352251 DOI: 10.1021/acsomega.2c02802] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/06/2022] [Accepted: 07/13/2022] [Indexed: 05/14/2023]
Abstract
Recent progress in the field of nanophotonics has opened up novel avenues for developing nanomaterial-based biosensing systems, which can detect various disease-specific biomarkers, including long noncoding RNAs (lncRNAs) known to circulate in biological fluids. Herein, we designed and developed a nanophotonic approach for rapid and specific capture of lncRNAs using oligonucleotide-conjugated graphene quantum-dot-nanoconjugates. The method offers accurate identification of the target lncRNAs with high selectivity, despite the presence of other molecules in the given sample. The observations also pointed toward the high feasibility and simplicity of the method in the selective determination of lncRNAs. Overall, the approach has the potential of assessing lncRNA expression as a function of disease initiation and progression.
Collapse
Affiliation(s)
- Ruchita Shandilya
- Department of Molecular Biology, ICMR-National Institute for Research in Environmental
Health, Bhopal 462030, India
| | - Arpit Bhargava
- Department of Molecular Biology, ICMR-National Institute for Research in Environmental
Health, Bhopal 462030, India
| | - Pooja Ratre
- Department of Molecular Biology, ICMR-National Institute for Research in Environmental
Health, Bhopal 462030, India
| | - Roshani Kumari
- Department of Molecular Biology, ICMR-National Institute for Research in Environmental
Health, Bhopal 462030, India
| | - Rajnarayan Tiwari
- Department of Molecular Biology, ICMR-National Institute for Research in Environmental
Health, Bhopal 462030, India
| | - Prachi Chauhan
- Department of Molecular Biology, ICMR-National Institute for Research in Environmental
Health, Bhopal 462030, India
| | - Pradyumna Kumar Mishra
- Department of Molecular Biology, ICMR-National Institute for Research in Environmental
Health, Bhopal 462030, India
| |
Collapse
|