1
|
Panditharatne SP, Imali DY, Perera ECJ, Perera LHR, Hettiarachchi GHCM, Kaumal MN. Anodized CuO-based reusable non-enzymatic glucose sensor as an alternative method for the analysis of pharmaceutical glucose infusions: a cyclic voltammetric approach. ANAL SCI 2024; 40:1475-1487. [PMID: 38727930 DOI: 10.1007/s44211-024-00585-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2024] [Accepted: 04/22/2024] [Indexed: 07/26/2024]
Abstract
Analyzing pharmaceutical products is a quality control requirement in a production facility. This study presents a CuO electrode-based reusable non-enzymatic sensor as an alternative method for rapid analysis of glucose levels in glucose infusions. CuO is extensively employed as an electrode material in non-enzymatic glucose sensors. Conventionally, these electrodes are fabricated using chemical synthesis of CuO followed by immobilization to the electrode substrate. In contrast, here, Cu metal was mechanically modified to create a grooved surface, followed by electrochemical anodization and subsequent annealing process to grow a seamless CuO layer in situ with enhanced catalytic activity. The morphology of the electrodes was characterized using scanning electron microscopy (SEM) and X-ray diffractometry (XRD). The direct electrocatalytic activity of the developed CuO-modified electrode towards glucose oxidation in alkaline media was investigated by cyclic voltammetry in detail. The CuO-modified electrode commenced the oxidation process around 0.10 V vs. Ag pseudo-reference electrode, demonstrating a significant reduction in the overvoltage for glucose oxidation compared to the bare Cu electrode. The sensor is capable of detecting glucose at low oxidation potentials such as 0.2 V with a sensitivity value of 0.37 µA ppm-1, a wide linear range (80-2300 ppm), limit of quantification (LOQ) of 1 ppm, greater repeatability, 1% precision, 3% bias, a short response time (80 s), good reproducibility and excellent reusability (196 consecutive attempts). The enhanced performance and cost-effectiveness make this sensor a promising alternative method for product analysis in glucose injection solutions.
Collapse
Affiliation(s)
| | - D Yureka Imali
- Department of Chemistry, University of Colombo, Colombo 03, Sri Lanka
| | - E Chavin J Perera
- Department of Chemistry, University of Colombo, Colombo 03, Sri Lanka
| | - L Hasini R Perera
- Department of Chemistry, University of Colombo, Colombo 03, Sri Lanka.
| | | | - M N Kaumal
- Department of Chemistry, University of Colombo, Colombo 03, Sri Lanka
| |
Collapse
|
2
|
Kuntoji G, Kousar N, Gaddimath S, Koodlur Sannegowda L. Macromolecule-Nanoparticle-Based Hybrid Materials for Biosensor Applications. BIOSENSORS 2024; 14:277. [PMID: 38920581 PMCID: PMC11201996 DOI: 10.3390/bios14060277] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/02/2024] [Revised: 04/21/2024] [Accepted: 04/26/2024] [Indexed: 06/27/2024]
Abstract
Biosensors function as sophisticated devices, converting biochemical reactions into electrical signals. Contemporary emphasis on developing biosensor devices with refined sensitivity and selectivity is critical due to their extensive functional capabilities. However, a significant challenge lies in the binding affinity of biosensors to biomolecules, requiring adept conversion and amplification of interactions into various signal modalities like electrical, optical, gravimetric, and electrochemical outputs. Overcoming challenges associated with sensitivity, detection limits, response time, reproducibility, and stability is essential for efficient biosensor creation. The central aspect of the fabrication of any biosensor is focused towards forming an effective interface between the analyte electrode which significantly influences the overall biosensor quality. Polymers and macromolecular systems are favored for their distinct properties and versatile applications. Enhancing the properties and conductivity of these systems can be achieved through incorporating nanoparticles or carbonaceous moieties. Hybrid composite materials, possessing a unique combination of attributes like advanced sensitivity, selectivity, thermal stability, mechanical flexibility, biocompatibility, and tunable electrical properties, emerge as promising candidates for biosensor applications. In addition, this approach enhances the electrochemical response, signal amplification, and stability of fabricated biosensors, contributing to their effectiveness. This review predominantly explores recent advancements in utilizing macrocyclic and macromolecular conjugated systems, such as phthalocyanines, porphyrins, polymers, etc. and their hybrids, with a specific focus on signal amplification in biosensors. It comprehensively covers synthetic strategies, properties, working mechanisms, and the potential of these systems for detecting biomolecules like glucose, hydrogen peroxide, uric acid, ascorbic acid, dopamine, cholesterol, amino acids, and cancer cells. Furthermore, this review delves into the progress made, elucidating the mechanisms responsible for signal amplification. The Conclusion addresses the challenges and future directions of macromolecule-based hybrids in biosensor applications, providing a concise overview of this evolving field. The narrative emphasizes the importance of biosensor technology advancement, illustrating the role of smart design and material enhancement in improving performance across various domains.
Collapse
Affiliation(s)
| | | | | | - Lokesh Koodlur Sannegowda
- Department of Studies in Chemistry, Vijayanagara Sri Krishnadevaraya University, Jnanasagara, Vinayakanagara, Ballari 583105, India; (G.K.); (N.K.); (S.G.)
| |
Collapse
|
3
|
Jeong YH, Kwon M, Shin S, Lee J, Kim KS. Biomedical Applications of CNT-Based Fibers. BIOSENSORS 2024; 14:137. [PMID: 38534244 DOI: 10.3390/bios14030137] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/13/2024] [Revised: 02/29/2024] [Accepted: 03/02/2024] [Indexed: 03/28/2024]
Abstract
Carbon nanotubes (CNTs) have been regarded as emerging materials in various applications. However, the range of biomedical applications is limited due to the aggregation and potential toxicity of powder-type CNTs. To overcome these issues, techniques to assemble them into various macroscopic structures, such as one-dimensional fibers, two-dimensional films, and three-dimensional aerogels, have been developed. Among them, carbon nanotube fiber (CNTF) is a one-dimensional aggregate of CNTs, which can be used to solve the potential toxicity problem of individual CNTs. Furthermore, since it has unique properties due to the one-dimensional nature of CNTs, CNTF has beneficial potential for biomedical applications. This review summarizes the biomedical applications using CNTF, such as the detection of biomolecules or signals for biosensors, strain sensors for wearable healthcare devices, and tissue engineering for regenerating human tissues. In addition, by considering the challenges and perspectives of CNTF for biomedical applications, the feasibility of CNTF in biomedical applications is discussed.
Collapse
Affiliation(s)
- Yun Ho Jeong
- School of Chemical Engineering, Pusan National University, Busan 46241, Republic of Korea
| | - Mina Kwon
- School of Chemical Engineering, Pusan National University, Busan 46241, Republic of Korea
| | - Sangsoo Shin
- School of Chemical Engineering, Pusan National University, Busan 46241, Republic of Korea
| | - Jaegeun Lee
- School of Chemical Engineering, Pusan National University, Busan 46241, Republic of Korea
- Department of Organic Material Science and Engineering, Pusan National University, Busan 46241, Republic of Korea
| | - Ki Su Kim
- School of Chemical Engineering, Pusan National University, Busan 46241, Republic of Korea
- Department of Organic Material Science and Engineering, Pusan National University, Busan 46241, Republic of Korea
- Institute of Advanced Organic Materials, Pusan National University, Busan 46241, Republic of Korea
| |
Collapse
|
4
|
Cong C, Subramanian S, Bodkhe GA, Wang G, Li Z, Wang R, Li X, Kim M, Kim SH. 3D Carbon-Based Conductive Network Printed for Glucose Sensors on Curved and Flexible Substrates. ACS APPLIED MATERIALS & INTERFACES 2024; 16:7543-7553. [PMID: 38297812 DOI: 10.1021/acsami.3c14757] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/02/2024]
Abstract
The rising prevalence of diabetes has led to an increased focus on real-time glucose monitoring. Wearable glucose sensor patches allow noninvasive, real-time monitoring, reducing patient discomfort compared to invasive sensors. However, most existing glucose sensor patches rely on complex and contaminating metal vapor deposition technologies, which pose limitations in practical production. In this study, we propose a novel approach for preparing graphite/multiwall carbon nanotubes (MWCNT)/reduced graphene oxide (rGO) using a high-viscosity ink, which can be easily obtained through simple mechanical stirring. To create intricate patterns and enable printing on curved substrates, we employed a 3D printer equipped with an infrared laser ranging system. The ink served as a working electrode, and we developed a three-electrode system patch with a concentric circle structure. Subsequently, the working electrode underwent enzymatic modification with glucose dehydrogenase with flavin adenine dinucleotide (GDH-FAD) using a polymer embedding method. The resulting wearable glucose sensor exhibited a sensitivity of 2.42 μA mM-1 and a linear detection range of 1-12 mM. In addition, the glucose sensor has excellent anti-interference capability and demonstrates good repeatability in simulated real human wear scenarios, which meets the requirements for accurate human detection. These findings provide valuable insights into the development of human health monitoring technologies.
Collapse
Affiliation(s)
- Chenhao Cong
- College of Mechanical and Electrical Engineering, Qingdao University, Qingdao 266071, China
- School of Chemical Engineering, Konkuk University, Seoul 05029, Republic of Korea
| | - Siva Subramanian
- Department of Food Science and Technology, Yeungnam University, Gyeongsan 38541, Republic of Korea
| | - Gajanan A Bodkhe
- Department of Food Science and Technology, Yeungnam University, Gyeongsan 38541, Republic of Korea
| | - Guangwei Wang
- College of Mechanical and Electrical Engineering, Qingdao University, Qingdao 266071, China
| | - Zhijun Li
- School of Chemical Engineering, Yeungnam University, Gyeongsan 38541, Republic of Korea
| | - Rixuan Wang
- School of Chemical Engineering, Yeungnam University, Gyeongsan 38541, Republic of Korea
| | - Xinlin Li
- College of Mechanical and Electrical Engineering, Qingdao University, Qingdao 266071, China
| | - Myunghee Kim
- Department of Food Science and Technology, Yeungnam University, Gyeongsan 38541, Republic of Korea
| | - Se Hyun Kim
- School of Chemical Engineering, Konkuk University, Seoul 05029, Republic of Korea
| |
Collapse
|
5
|
Govindaraj M, Srivastava A, Muthukumaran MK, Tsai PC, Lin YC, Raja BK, Rajendran J, Ponnusamy VK, Arockia Selvi J. Current advancements and prospects of enzymatic and non-enzymatic electrochemical glucose sensors. Int J Biol Macromol 2023; 253:126680. [PMID: 37673151 DOI: 10.1016/j.ijbiomac.2023.126680] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2023] [Revised: 08/19/2023] [Accepted: 09/01/2023] [Indexed: 09/08/2023]
Abstract
This review discusses the most current developments and future perspectives in enzymatic and non-enzymatic glucose sensors, which have notably evolved over the preceding quadrennial period. Furthermore, a thorough exploration encompassed the sensor's intricate fabrication processes, the diverse range of materials employed, the underlying principles of detection, and an in-depth assessment of the sensors' efficacy in detecting glucose levels within essential bodily fluids such as human blood serums, urine, saliva, and interstitial fluids. It is worth noting that the accurate quantification of glucose concentrations within human blood has been effectively achieved by utilizing classical enzymatic sensors harmoniously integrated with optical and electrochemical transduction mechanisms. Monitoring glucose levels in various mediums has attracted exceptional attention from industrial to academic researchers for diabetes management, food quality control, clinical medicine, and bioprocess inspection. There has been an enormous demand for the creation of novel glucose sensors over the past ten years. Research has primarily concentrated on succeeding biocompatible and enhanced sensing abilities related to the present technologies, offering innovative avenues for more effective glucose sensors. Recent developments in wearable optical and electrochemical sensors with low cost, high stability, point-of-care testing, and online tracking of glucose concentration levels in biological fluids can aid in managing and controlling diabetes globally. New nanomaterials and biomolecules that can be used in electrochemical sensor systems to identify glucose concentration levels are developed thanks to advances in nanoscience and nanotechnology. Both enzymatic and non-enzymatic glucose electrochemical sensors have garnered much interest recently and have made significant strides in detecting glucose levels. In this review, we summarise several categories of non-enzymatic glucose sensor materials, including composites, non-precious transition metals and their metal oxides, hydroxides, precious metals and their alloys, carbon-based materials, conducting polymers, metal-organic framework (MOF)-based electrocatalysts, and wearable device-based glucose sensors deeply.
Collapse
Affiliation(s)
- Muthukumar Govindaraj
- Department of Chemistry, SRM Institute of Science and Technology, Kattankulathur 603203, Tamil Nadu, India; Department of Medicinal and Applied Chemistry, Kaohsiung Medical University (KMU), Kaohsiung City 807, Taiwan
| | - Ananya Srivastava
- Department of Chemistry, Institute of Science, Banaras Hindu University, Varanasi 221005, India
| | - Magesh Kumar Muthukumaran
- Department of Chemistry, SRM Institute of Science and Technology, Kattankulathur 603203, Tamil Nadu, India
| | - Pei-Chien Tsai
- Department of Medicinal and Applied Chemistry, Kaohsiung Medical University (KMU), Kaohsiung City 807, Taiwan; Department of Computational Biology, Institute of Bioinformatics, Saveetha School of Engineering, Saveetha Institute of Medical and Technical Sciences, Chennai, Tamil Nadu, 602105, India
| | - Yuan-Chung Lin
- Institute of Environmental Engineering, National Sun Yat-sen University, Kaohsiung 804, Taiwan; Center for Emerging Contaminants Research, National Sun Yat-sen University, Kaohsiung 804, Taiwan.
| | - Bharathi Kannan Raja
- Department of Chemistry, SRM Institute of Science and Technology, Kattankulathur 603203, Tamil Nadu, India
| | - Jerome Rajendran
- Department of Electrical Engineering and Computer Science, The University of California, Irvine, CA 92697, United States
| | - Vinoth Kumar Ponnusamy
- Department of Medicinal and Applied Chemistry, Kaohsiung Medical University (KMU), Kaohsiung City 807, Taiwan; Center for Emerging Contaminants Research, National Sun Yat-sen University, Kaohsiung 804, Taiwan; Research Center for Precision Environmental Medicine, Kaohsiung Medical University (KMU), Kaohsiung City 807, Taiwan; Department of Medical Research, Kaohsiung Medical University Hospital (KMUH), Kaohsiung Medical University, Kaohsiung City 807, Taiwan; Department of Chemistry, National Sun Yat-sen University (NSYSU), Kaohsiung City 804, Taiwan.
| | - J Arockia Selvi
- Department of Chemistry, SRM Institute of Science and Technology, Kattankulathur 603203, Tamil Nadu, India.
| |
Collapse
|
6
|
Maduraiveeran G. Enzyme-free electrochemical sensor platforms based on transition metal nanostructures for clinical diagnostics. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2023; 15:6620-6630. [PMID: 38047319 DOI: 10.1039/d3ay01849k] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/05/2023]
Abstract
The detection of emergent biomarkers is of key significance in numerous clinical, biological, and biomedical fields. Specifically, the design and development of potent electrochemical lactic acid and glucose sensing platforms are especially in great demand in a variety of industries, including those involved in clinical analysis, biomedicine, biological, food, cosmetics, pharmaceuticals, leather, sports, and chemical industries. Nanostructured transition metal-derived materials have opened the door to electrochemical sensors and biosensors due to their advantages of high surface-to-volume ratio, surface reaction activity, catalytic activity, and strong adsorption capability. The primary aim of the present minireview is to highlight the advancement of enzyme-free electrochemical sensor platforms based on transition metal-derived nanostructures with high electrocatalytic activity and sensing performance towards lactic acid and glucose in practical samples. The preparation approaches, structural and composition monitoring, fabrication of sensing electrodes, catalytic activity, sensing performance in real samples, and the exploration of sensing mechanisms are majorly concentrated on in most of our recent research studies. Moreover, state-of-the-art transition metal-derived nanostructure-derived electrochemical sensor platforms, critical comparison of the analytical performance of the sensor platforms, and the future perspectives of the enzyme-free electrochemical sensor for clinical diagnostics are described.
Collapse
Affiliation(s)
- Govindhan Maduraiveeran
- Materials Electrochemistry Laboratory, Department of Chemistry, Faculty of Engineering and Technology, SRM Institute of Science and Technology, Kattankulathur 603 203, Chengalpattu, Tamil Nadu, India.
| |
Collapse
|
7
|
Hassan IU. Diabetes Management by Fourth-Generation Glucose Sensors Based on Lemon-Extract-Supported CuO Nanoporous Materials. Molecules 2023; 28:6763. [PMID: 37836606 PMCID: PMC10574443 DOI: 10.3390/molecules28196763] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2023] [Revised: 09/11/2023] [Accepted: 09/18/2023] [Indexed: 10/15/2023] Open
Abstract
Diabetes is a major worldwide health issue, impacting millions of people around the globe and putting pressure on healthcare systems. Accurate detection of glucose is critical for efficient diabetes care, because it allows for prompt action to control blood sugar levels and avoid problems. Reliable glucose-sensing devices provide individuals with real-time information, allowing them to make more educated food, medicine, and lifestyle decisions. The progress of glucose sensing holds the key to increasing the quality of life for diabetics and lowering the burden of this prevalent condition. The present investigation addresses the synthesis of a CuO@lemon-extract nanoporous material using the sol-gel process. Scanning electron microscopy (SEM) and transmission electron microscopy (TEM) were used to analyze the morphological properties of the composite, which revealed a homogeneous integration of CuO nanoparticles (NPs) on the surface of the matrix. The existence of primarily oxidized copper species, especially CuO, was confirmed by X-ray diffraction spectroscopy (XRD) investigation in combination with energy-dispersive X-ray (EDX) spectroscopy. The CuO@lemon-extract-modified glassy carbon electrode (CuO@lemon-extract GCE) performed well in non-enzymatic electrochemical sensing applications such as differential pulse voltammetry (DPV) and amperometric glucose detection. The electrode achieved a notable sensitivity of 3293 µA mM-1 cm-2 after careful adjustment, with a noticeable detection limit of 0.01 µM (signal-to-noise ratio of 3). The operational range of the electrode was 0.01 µM to 0.2 µM, with potential applied of 0.53 V vs. Ag/AgCl. These findings underscore the CuO@lemon-extract GCE's promise as a robust and reliable platform for electrochemical glucose sensing, promising advances in non-enzymatic glucose sensing (NEGS) techniques.
Collapse
Affiliation(s)
- Israr U Hassan
- Department of Mathematics & Sciences, College of Arts & Applied Sciences, Dhofar University, Salalah PC 211, Oman
| |
Collapse
|
8
|
Yuwen T, Shu D, Zou H, Yang X, Wang S, Zhang S, Liu Q, Wang X, Wang G, Zhang Y, Zang G. Carbon nanotubes: a powerful bridge for conductivity and flexibility in electrochemical glucose sensors. J Nanobiotechnology 2023; 21:320. [PMID: 37679841 PMCID: PMC10483845 DOI: 10.1186/s12951-023-02088-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2023] [Accepted: 08/29/2023] [Indexed: 09/09/2023] Open
Abstract
The utilization of nanomaterials in the biosensor field has garnered substantial attention in recent years. Initially, the emphasis was on enhancing the sensor current rather than material interactions. However, carbon nanotubes (CNTs) have gained prominence in glucose sensors due to their high aspect ratio, remarkable chemical stability, and notable optical and electronic attributes. The diverse nanostructures and metal surface designs of CNTs, coupled with their exceptional physical and chemical properties, have led to diverse applications in electrochemical glucose sensor research. Substantial progress has been achieved, particularly in constructing flexible interfaces based on CNTs. This review focuses on CNT-based sensor design, manufacturing advancements, material synergy effects, and minimally invasive/noninvasive glucose monitoring devices. The review also discusses the trend toward simultaneous detection of multiple markers in glucose sensors and the pivotal role played by CNTs in this trend. Furthermore, the latest applications of CNTs in electrochemical glucose sensors are explored, accompanied by an overview of the current status, challenges, and future prospects of CNT-based sensors and their potential applications.
Collapse
Affiliation(s)
- Tianyi Yuwen
- Institute of Life Science, and Laboratory of Tissue and Cell Biology, Lab Teaching & Management Center, Chongqing Medical University, Chongqing, 400016, China
| | - Danting Shu
- Institute of Life Science, and Laboratory of Tissue and Cell Biology, Lab Teaching & Management Center, Chongqing Medical University, Chongqing, 400016, China
| | - Hanyan Zou
- Chongqing Institute for Food and Drug Control, Chongqing, 401121, China
| | - Xinrui Yang
- Institute of Life Science, and Laboratory of Tissue and Cell Biology, Lab Teaching & Management Center, Chongqing Medical University, Chongqing, 400016, China
| | - Shijun Wang
- Institute of Life Science, and Laboratory of Tissue and Cell Biology, Lab Teaching & Management Center, Chongqing Medical University, Chongqing, 400016, China
| | - Shuheng Zhang
- Institute of Life Science, and Laboratory of Tissue and Cell Biology, Lab Teaching & Management Center, Chongqing Medical University, Chongqing, 400016, China
| | - Qichen Liu
- Institute of Life Science, and Laboratory of Tissue and Cell Biology, Lab Teaching & Management Center, Chongqing Medical University, Chongqing, 400016, China
| | - Xiangxiu Wang
- Key Laboratory of Biorheological and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing, 400030, China
- JinFeng Laboratory, Chongqing, 401329, China
- Chongqing Institute for Food and Drug Control, Chongqing, 401121, China
| | - Guixue Wang
- Key Laboratory of Biorheological and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing, 400030, China.
- JinFeng Laboratory, Chongqing, 401329, China.
| | - Yuchan Zhang
- Institute of Life Science, and Laboratory of Tissue and Cell Biology, Lab Teaching & Management Center, Chongqing Medical University, Chongqing, 400016, China.
| | - Guangchao Zang
- Institute of Life Science, and Laboratory of Tissue and Cell Biology, Lab Teaching & Management Center, Chongqing Medical University, Chongqing, 400016, China.
- JinFeng Laboratory, Chongqing, 401329, China.
| |
Collapse
|
9
|
Fatima S, Iqbal M, Bhatti HN, Iqbal M, Alwadai N, Al Huwayz M, Nazir A. Synthesis of Oval-Shaped Bi 2Al 4O 9 Nanoparticles and Their Applications for the Degradation of Acid Green 25 and as Fuel Additives. ACS OMEGA 2023; 8:30868-30878. [PMID: 37663520 PMCID: PMC10468761 DOI: 10.1021/acsomega.3c01245] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/24/2023] [Accepted: 08/08/2023] [Indexed: 09/05/2023]
Abstract
The present study was designed to synthesize an oval-shaped bimetallic bismuth aluminate (Bi2Al4O9) nanoparticles through a solvothermal approach. The resulting structure and morphology of synthesized materials were characterized through X-ray diffraction and scanning electron microscopy. The catalytic performance of Bi2Al4O9 was investigated using acid green 25 (AG-25) as the model dye. The effect of various parameters like catalyst dose, H2O2 concentration, and temperature on dye degradation was studied. The Bi2Al4O9 nanocomposite exhibited the maximum removal of 95% within 50 min at 0.3 M H2O2 concentration, 0.05 mg/mL catalyst dose, and 315 K temperature. The photocatalytic removal of AG-25 followed pseudo-first-order kinetics. The thermodynamics study exposed that thermal catalytic degradation is a spontaneous, endothermic, as well as entropy-driven reaction that moves in the forward direction at the higher temperatures. The Bi2Al4O9 composite was further applied as fuel additives in order to study combustion and physical characteristics of the modified fuel. The efficacy of modified fuel was studied by investigating the fuel parameters at different Bi2Al4O9 dosages. Results revealed that synthesized NPs are excellent photocatalysts and could possibly be used for the removal of toxic pollutants.
Collapse
Affiliation(s)
- Shumaila Fatima
- Environmental
Chemistry Laboratory, Department of Chemistry, University of Agriculture Faisalabad, Faisalabad 38000, Pakistan
| | - Mahwish Iqbal
- Environmental
Chemistry Laboratory, Department of Chemistry, University of Agriculture Faisalabad, Faisalabad 38000, Pakistan
| | - Haq Nawaz Bhatti
- Environmental
Chemistry Laboratory, Department of Chemistry, University of Agriculture Faisalabad, Faisalabad 38000, Pakistan
| | - Munawar Iqbal
- Department
of Chemistry, Division of Science and Technology, University of Education, Lahore 53700, Pakistan
| | - Norah Alwadai
- Department
of Physics, College of Science, Princess Nourah bint Abdulrahman, University (PNU), Riyadh 11671, Saudi Arabia
| | - Maryam Al Huwayz
- Department
of Physics, College of Science, Princess Nourah bint Abdulrahman, University (PNU), Riyadh 11671, Saudi Arabia
| | - Arif Nazir
- Department
of Chemistry, The University of Lahore, Lahore 54000, Pakistan
| |
Collapse
|
10
|
Vanaraj R, Arumugam B, Mayakrishnan G, Kim IS, Kim SC. A Review on Electrospun Nanofiber Composites for an Efficient Electrochemical Sensor Applications. SENSORS (BASEL, SWITZERLAND) 2023; 23:6705. [PMID: 37571489 PMCID: PMC10422532 DOI: 10.3390/s23156705] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/19/2023] [Revised: 07/21/2023] [Accepted: 07/24/2023] [Indexed: 08/13/2023]
Abstract
The present review article discusses the elementary concepts of the sensor mechanism and various types of materials used for sensor applications. The electrospinning method is the most comfortable method to prepare the device-like structure by means of forming from the fiber structure. Though there are various materials available for sensors, the important factor is to incorporate the functional group on the surface of the materials. The post-modification sanction enhances the efficiency of the sensor materials. This article also describes the various types of materials applied to chemical and biosensor applications. The chemical sensor parts include acetone, ethanol, ammonia, and CO2, H2O2, and NO2 molecules; meanwhile, the biosensor takes on glucose, uric acid, and cholesterol molecules. The above materials have to be sensed for a healthier lifestyle for humans and other living organisms. The prescribed review articles give a detailed report on the Electrospun materials for sensor applications.
Collapse
Affiliation(s)
- Ramkumar Vanaraj
- School of Chemical Engineering, Yeungnam University, Gyeonsan 38541, Republic of Korea; (R.V.); (B.A.)
| | - Bharathi Arumugam
- School of Chemical Engineering, Yeungnam University, Gyeonsan 38541, Republic of Korea; (R.V.); (B.A.)
| | - Gopiraman Mayakrishnan
- Nano Fusion Technology Research Group, Division of Molecules and Polymers, Institute for Fiber Engineering (IFES), Interdisciplinary Cluster for Cutting Edge Research (ICCER), Shinshu University, Tokida 3-15-1, Ueda 386-8567, Nagano, Japan;
| | - Ick Soo Kim
- Nano Fusion Technology Research Group, Division of Molecules and Polymers, Institute for Fiber Engineering (IFES), Interdisciplinary Cluster for Cutting Edge Research (ICCER), Shinshu University, Tokida 3-15-1, Ueda 386-8567, Nagano, Japan;
| | - Seong Cheol Kim
- School of Chemical Engineering, Yeungnam University, Gyeonsan 38541, Republic of Korea; (R.V.); (B.A.)
| |
Collapse
|
11
|
Chi L, Zhang C, Wu X, Qian X, Sun H, He M, Guo C. Research Progress on Biomimetic Nanomaterials for Electrochemical Glucose Sensors. Biomimetics (Basel) 2023; 8:biomimetics8020167. [PMID: 37092419 PMCID: PMC10123724 DOI: 10.3390/biomimetics8020167] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2023] [Revised: 04/16/2023] [Accepted: 04/17/2023] [Indexed: 04/25/2023] Open
Abstract
Diabetes has become a chronic disease that necessitates timely and accurate detection. Among various detection methods, electrochemical glucose sensors have attracted much attention because of low cost, real-time detection, and simple and easy operation. Nonenzymatic biomimetic nanomaterials are the vital part in electrochemical glucose sensors. This review article summarizes the methods to enhance the glucose sensing performance of noble metal, transition metal oxides, and carbon-based materials and introduces biomimetic nanomaterials used in noninvasive glucose detection in sweat, tear, urine, and saliva. Based on these, this review provides the foundation for noninvasive determination of trace glucose for diabetic patients in the future.
Collapse
Affiliation(s)
- Lili Chi
- School of Materials Science and Engineering, Suzhou University of Science and Technology, Suzhou 215009, China
| | - Chunmei Zhang
- School of Materials Science and Engineering, Suzhou University of Science and Technology, Suzhou 215009, China
| | - Xuanyu Wu
- School of Materials Science and Engineering, Suzhou University of Science and Technology, Suzhou 215009, China
- School of Environmental Science and Engineering, Suzhou University of Science and Technology, Suzhou 215009, China
| | - Xianghao Qian
- School of Materials Science and Engineering, Suzhou University of Science and Technology, Suzhou 215009, China
| | - Hao Sun
- School of Materials Science and Engineering, Suzhou University of Science and Technology, Suzhou 215009, China
| | - Mengru He
- School of Materials Science and Engineering, Suzhou University of Science and Technology, Suzhou 215009, China
| | - Chunxian Guo
- School of Materials Science and Engineering, Suzhou University of Science and Technology, Suzhou 215009, China
| |
Collapse
|