• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4624131)   Today's Articles (38)   Subscriber (49410)
For: Baker BR, Lai RY, Wood MS, Doctor EH, Heeger AJ, Plaxco KW. An electronic, aptamer-based small-molecule sensor for the rapid, label-free detection of cocaine in adulterated samples and biological fluids. J Am Chem Soc 2006;128:3138-9. [PMID: 16522082 DOI: 10.1021/ja056957p] [Citation(s) in RCA: 597] [Impact Index Per Article: 33.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Number Cited by Other Article(s)
1
Lu W, Lou S, Yang B, Guo Z, Tian Z. Light-activated oxidative capacity of isoquinoline alkaloids for universal, homogeneous, reliable, colorimetric assays with DNA aptamers. Talanta 2024;279:126667. [PMID: 39111217 DOI: 10.1016/j.talanta.2024.126667] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2024] [Revised: 07/31/2024] [Accepted: 08/02/2024] [Indexed: 09/01/2024]
2
Zhang X, Wang Y, He X, Yang Y, Chen X, Li J. Advances in microneedle technology for biomedical detection. Biomater Sci 2024. [PMID: 39225488 DOI: 10.1039/d4bm00794h] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/04/2024]
3
Raina J, Kaur G, Singh I. Recent progress in nanomaterial-based aptamers as biosensors for point of care detection of Hg2+ ions and its environmental applications. Talanta 2024;277:126372. [PMID: 38865954 DOI: 10.1016/j.talanta.2024.126372] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2024] [Revised: 05/29/2024] [Accepted: 06/05/2024] [Indexed: 06/14/2024]
4
Dominique E, Renault C. Towards the rational design of N-(1,3-dimethylbutyl)-N'-phenyl-1,4-benzenediamine (6PPD) electrochemical sensor. Analyst 2024. [PMID: 39196540 DOI: 10.1039/d4an00973h] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/29/2024]
5
Alawneh A, Wettasinghe AP, McMullen R, Seifi MO, Breton I, Slinker JD, Kuchta RD. A Redox-Reversible Switch of DNA Hydrogen Bonding and Structure. ACS APPLIED BIO MATERIALS 2024;7:5308-5317. [PMID: 38978451 DOI: 10.1021/acsabm.4c00529] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/10/2024]
6
Gupta V, Pham A, Dick JE. Planar Disk μ-Aptasensors by Monolayer Assembly in a Dissolving Microdroplet. Anal Chem 2024. [PMID: 39152900 DOI: 10.1021/acs.analchem.4c01043] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/19/2024]
7
Dong Y, Wang J, Chen L, Chen H, Dang S, Li F. Aptamer-based assembly systems for SARS-CoV-2 detection and therapeutics. Chem Soc Rev 2024;53:6830-6859. [PMID: 38829187 DOI: 10.1039/d3cs00774j] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/05/2024]
8
Wan J, Tian Y, Wu D, Ye Z, Chen S, Hu Q, Wang M, Lv J, Xu W, Zhang X, Han D, Niu L. Site-Directed Electrochemical Grafting for Amplified Detection of Antibody Pharmaceuticals. Anal Chem 2024;96:9278-9284. [PMID: 38768425 DOI: 10.1021/acs.analchem.4c01798] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/22/2024]
9
Lu Y, Cao Y, Tang X, Hu N, Wang Z, Xu P, Hua Z, Wang Y, Su Y, Guo Y. Deep learning-assisted mass spectrometry imaging for preliminary screening and pre-classification of psychoactive substances. Talanta 2024;272:125757. [PMID: 38368831 DOI: 10.1016/j.talanta.2024.125757] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2023] [Revised: 01/28/2024] [Accepted: 02/05/2024] [Indexed: 02/20/2024]
10
Abeykoon SW, White RJ. Single Voltammetric Sweep Calibration-Free Interrogation of Electrochemical Aptamer-Based Sensors Employing Continuous Square Wave Voltammetry. Anal Chem 2024;96:6958-6967. [PMID: 38662230 DOI: 10.1021/acs.analchem.3c05920] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/26/2024]
11
Yu H, Zhao Q. Sensitive electrochemical sensor for Cd2+ with engineered short high-affinity aptamer undergoing large conformation change. Talanta 2024;271:125642. [PMID: 38237283 DOI: 10.1016/j.talanta.2024.125642] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2023] [Revised: 12/24/2023] [Accepted: 01/06/2024] [Indexed: 02/24/2024]
12
Wu Y, Shi J, Kippin TE, Plaxco KW. Codeposition Enhances the Performance of Electrochemical Aptamer-Based Sensors. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2024;40:8703-8710. [PMID: 38616608 DOI: 10.1021/acs.langmuir.4c00585] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/16/2024]
13
Wu C, Yan L, Zhan Z, Qu R, Wang Y, Zeng X, Yang H, Feng P, Wei Z, Chen P. Biomolecules-mediated electrochemical signals of Cu2+: Y-DNA nanomachines enable homogeneous rapid one-step assay of lung cancer circulating tumor cells. Biosens Bioelectron 2024;249:116030. [PMID: 38241796 DOI: 10.1016/j.bios.2024.116030] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2023] [Revised: 01/01/2024] [Accepted: 01/10/2024] [Indexed: 01/21/2024]
14
Xie Y, She JP, Zheng JX, Salminen K, Sun JJ. Rapid nanomolar detection of Δ9-tetrahydrocannabinol in biofluids via electrochemical aptamer-based biosensor. Anal Chim Acta 2024;1295:342304. [PMID: 38355229 DOI: 10.1016/j.aca.2024.342304] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2023] [Revised: 01/15/2024] [Accepted: 01/28/2024] [Indexed: 02/16/2024]
15
Yang K, Alkhamis O, Canoura J, Bryant A, Gong EM, Barbu M, Taylor S, Nikic D, Banerjee S, Xiao Y, Stojanovic MN, Landry DW. Exploring the Landscape of Aptamers: From Cross-Reactive to Selective to Specific, High-Affinity Receptors for Cocaine. JACS AU 2024;4:760-770. [PMID: 38425914 PMCID: PMC10900216 DOI: 10.1021/jacsau.3c00781] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/07/2023] [Revised: 01/25/2024] [Accepted: 01/25/2024] [Indexed: 03/02/2024]
16
Liu C, Shen X, Yan L, Qu R, Wang Y, He Y, Zhan Z, Chen P, Lin F. Controllable self-assembled DNA nanomachine enable homogeneous rapid electrochemical one-pot assay of lung cancer circulating tumor cells. Biosens Bioelectron 2024;246:115865. [PMID: 38035517 DOI: 10.1016/j.bios.2023.115865] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2023] [Revised: 11/17/2023] [Accepted: 11/18/2023] [Indexed: 12/02/2023]
17
Alkhamis O, Canoura J, Wu Y, Emmons NA, Wang Y, Honeywell KM, Plaxco KW, Kippin TE, Xiao Y. High-Affinity Aptamers for In Vitro and In Vivo Cocaine Sensing. J Am Chem Soc 2024;146:3230-3240. [PMID: 38277259 DOI: 10.1021/jacs.3c11350] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2024]
18
Chamorro A, Rossetti M, Bagheri N, Porchetta A. Rationally Designed DNA-Based Scaffolds and Switching Probes for Protein Sensing. ADVANCES IN BIOCHEMICAL ENGINEERING/BIOTECHNOLOGY 2024;187:71-106. [PMID: 38273204 DOI: 10.1007/10_2023_235] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/27/2024]
19
Kumakli H, Baldwin M, Abeykoon SW, White RJ. Microscale, Electrochemical, Aptamer-Based Sensors for Enhanced Small-Molecule Detection at Millisecond Time Scales. ACS Sens 2023;8:4521-4530. [PMID: 38104257 PMCID: PMC11059485 DOI: 10.1021/acssensors.3c01055] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2023]
20
Canoura J, Liu Y, Alkhamis O, Xiao Y. Aptamer-Based Fentanyl Detection in Biological Fluids. Anal Chem 2023;95:18258-18267. [PMID: 38033203 DOI: 10.1021/acs.analchem.3c04104] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/02/2023]
21
Myres GJ, Kitt JP, Harris JM. Raman Scattering Reveals Ion-Dependent G-Quadruplex Formation in the 15-mer Thrombin-Binding Aptamer upon Association with α-Thrombin. Anal Chem 2023;95:16160-16168. [PMID: 37870982 DOI: 10.1021/acs.analchem.3c02751] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2023]
22
Nguyen TTH, Nguyen CM, Huynh MA, Vu HH, Nguyen TK, Nguyen NT. Field effect transistor based wearable biosensors for healthcare monitoring. J Nanobiotechnology 2023;21:411. [PMID: 37936115 PMCID: PMC10629051 DOI: 10.1186/s12951-023-02153-1] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2023] [Accepted: 10/09/2023] [Indexed: 11/09/2023]  Open
23
Singh M, Kumar J. Flourescence sensors for heavy metal detection: major contaminants in soil and water bodies. ANAL SCI 2023;39:1829-1838. [PMID: 37531068 DOI: 10.1007/s44211-023-00392-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2023] [Accepted: 06/28/2023] [Indexed: 08/03/2023]
24
Wu G, Zhang ET, Qiang Y, Esmonde C, Chen X, Wei Z, Song Y, Zhang X, Schneider MJ, Li H, Sun H, Weng Z, Santaniello S, He J, Lai RY, Li Y, Bruchas MR, Zhang Y. Long-Term In Vivo Molecular Monitoring Using Aptamer-Graphene Microtransistors. BIORXIV : THE PREPRINT SERVER FOR BIOLOGY 2023:2023.10.18.562080. [PMID: 37905115 PMCID: PMC10614860 DOI: 10.1101/2023.10.18.562080] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/02/2023]
25
Bekkouche I, Kuznetsova MN, Rejepov DT, Vetcher AA, Shishonin AY. Recent Advances in DNA Nanomaterials. NANOMATERIALS (BASEL, SWITZERLAND) 2023;13:2449. [PMID: 37686956 PMCID: PMC10490369 DOI: 10.3390/nano13172449] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/20/2023] [Revised: 08/16/2023] [Accepted: 08/17/2023] [Indexed: 09/10/2023]
26
Yuwen L, Zhang S, Chao J. Recent Advances in DNA Nanotechnology-Enabled Biosensors for Virus Detection. BIOSENSORS 2023;13:822. [PMID: 37622908 PMCID: PMC10452139 DOI: 10.3390/bios13080822] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/15/2023] [Revised: 08/05/2023] [Accepted: 08/12/2023] [Indexed: 08/26/2023]
27
Bazyar H. On the Application of Microfluidic-Based Technologies in Forensics: A Review. SENSORS (BASEL, SWITZERLAND) 2023;23:5856. [PMID: 37447704 PMCID: PMC10346202 DOI: 10.3390/s23135856] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/17/2023] [Revised: 06/21/2023] [Accepted: 06/22/2023] [Indexed: 07/15/2023]
28
Yang LF, Ling M, Kacherovsky N, Pun SH. Aptamers 101: aptamer discovery and in vitro applications in biosensors and separations. Chem Sci 2023;14:4961-4978. [PMID: 37206388 PMCID: PMC10189874 DOI: 10.1039/d3sc00439b] [Citation(s) in RCA: 28] [Impact Index Per Article: 28.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2023] [Accepted: 04/14/2023] [Indexed: 05/21/2023]  Open
29
Stelmaszczyk P, Kwaczyński K, Rudnicki K, Skrzypek S, Wietecha-Posłuszny R, Poltorak L. Nitrazepam and 7-aminonitrazepam studied at the macroscopic and microscopic electrified liquid-liquid interface. Mikrochim Acta 2023;190:182. [PMID: 37052720 PMCID: PMC10101902 DOI: 10.1007/s00604-023-05739-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2022] [Accepted: 03/09/2023] [Indexed: 04/14/2023]
30
Clark V, Pellitero MA, Arroyo-Currás N. Explaining the Decay of Nucleic Acid-Based Sensors under Continuous Voltammetric Interrogation. Anal Chem 2023;95:4974-4983. [PMID: 36881708 PMCID: PMC10035425 DOI: 10.1021/acs.analchem.2c05158] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2022] [Accepted: 02/23/2023] [Indexed: 03/09/2023]
31
Shaver A, Arroyo-Currás N. Expanding the Monolayer Scope for Nucleic Acid-Based Electrochemical Sensors Beyond Thiols on Gold: Alkylphosphonic Acids on ITO. ECS SENSORS PLUS 2023;2:010601. [PMID: 37006966 PMCID: PMC10053865 DOI: 10.1149/2754-2726/acc4d9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/27/2023] [Revised: 03/15/2023] [Indexed: 03/18/2023]
32
Parolo C, Idili A, Heikenfeld J, Plaxco KW. Conformational-switch biosensors as novel tools to support continuous, real-time molecular monitoring in lab-on-a-chip devices. LAB ON A CHIP 2023;23:1339-1348. [PMID: 36655710 PMCID: PMC10799767 DOI: 10.1039/d2lc00716a] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/17/2023]
33
Myres GJ, Harris JM. Stable Immobilization of DNA to Silica Surfaces by Sequential Michael Addition Reactions Developed with Insights from Confocal Raman Microscopy. Anal Chem 2023;95:3499-3506. [PMID: 36718639 DOI: 10.1021/acs.analchem.2c05594] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
34
Rahbarimehr E, Chao HP, Churcher ZR, Slavkovic S, Kaiyum YA, Johnson PE, Dauphin-Ducharme P. Finding the Lost Dissociation Constant of Electrochemical Aptamer-Based Biosensors. Anal Chem 2023;95:2229-2237. [PMID: 36638814 DOI: 10.1021/acs.analchem.2c03566] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
35
Wu B, Castagnola E, Cui XT. Zwitterionic Polymer Coated and Aptamer Functionalized Flexible Micro-Electrode Arrays for In Vivo Cocaine Sensing and Electrophysiology. MICROMACHINES 2023;14:323. [PMID: 36838023 PMCID: PMC9967584 DOI: 10.3390/mi14020323] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/17/2022] [Revised: 01/19/2023] [Accepted: 01/25/2023] [Indexed: 06/18/2023]
36
Futane A, Narayanamurthy V, Jadhav P, Srinivasan A. Aptamer-based rapid diagnosis for point-of-care application. MICROFLUIDICS AND NANOFLUIDICS 2023;27:15. [PMID: 36688097 PMCID: PMC9847464 DOI: 10.1007/s10404-022-02622-3] [Citation(s) in RCA: 13] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/28/2022] [Accepted: 12/31/2022] [Indexed: 05/31/2023]
37
Huang Z, Hu B, Wang H. Analytical methods for microplastics in the environment: a review. ENVIRONMENTAL CHEMISTRY LETTERS 2023;21:383-401. [PMID: 36196263 PMCID: PMC9521859 DOI: 10.1007/s10311-022-01525-7] [Citation(s) in RCA: 33] [Impact Index Per Article: 33.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/01/2022] [Accepted: 07/21/2022] [Indexed: 05/06/2023]
38
Li Y, Hua X, Wang J, Jin B. cMWCNT/CoHCF/AuNPs nanocomposites aptasensor for electrochemical detection of interleukin-6. TALANTA OPEN 2023. [DOI: 10.1016/j.talo.2023.100188] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]  Open
39
Hashem A, Hossain MAM, Marlinda AR, Mamun MA, Simarani K, Johan MR. Rapid and sensitive detection of box turtles using an electrochemical DNA biosensor based on a gold/graphene nanocomposite. BEILSTEIN JOURNAL OF NANOTECHNOLOGY 2022;13:1458-1472. [PMID: 36570614 PMCID: PMC9749552 DOI: 10.3762/bjnano.13.120] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 05/05/2022] [Accepted: 11/16/2022] [Indexed: 06/17/2023]
40
M Silva S, Langley DP, Cossins LR, Samudra AN, Quigley AF, Kapsa RMI, Tothill RW, Greene GW, Moulton SE. Rapid Point-of-Care Electrochemical Sensor for the Detection of Cancer Tn Antigen Carbohydrate in Whole Unprocessed Blood. ACS Sens 2022;7:3379-3388. [PMID: 36374944 DOI: 10.1021/acssensors.2c01460] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
41
Downs AM, Plaxco KW. Real-Time, In Vivo Molecular Monitoring Using Electrochemical Aptamer Based Sensors: Opportunities and Challenges. ACS Sens 2022;7:2823-2832. [PMID: 36205360 PMCID: PMC9840907 DOI: 10.1021/acssensors.2c01428] [Citation(s) in RCA: 27] [Impact Index Per Article: 13.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
42
Chamorro-Garcia A, Parolo C, Ortega G, Idili A, Green J, Ricci F, Plaxco KW. The sequestration mechanism as a generalizable approach to improve the sensitivity of biosensors and bioassays. Chem Sci 2022;13:12219-12228. [PMID: 36349092 PMCID: PMC9601244 DOI: 10.1039/d2sc03901j] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2022] [Accepted: 09/16/2022] [Indexed: 07/25/2023]  Open
43
Onaş AM, Dascălu C, Raicopol MD, Pilan L. Critical Design Factors for Electrochemical Aptasensors Based on Target-Induced Conformational Changes: The Case of Small-Molecule Targets. BIOSENSORS 2022;12:816. [PMID: 36290952 PMCID: PMC9599214 DOI: 10.3390/bios12100816] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/03/2022] [Revised: 09/19/2022] [Accepted: 09/23/2022] [Indexed: 06/16/2023]
44
Xu R, Yang C, Huang L, Lv W, Yang W, Wu Y, Fu F. Broad-Specificity Aptamer of Sulfonamides: Isolation and Its Application in Simultaneous Detection of Multiple Sulfonamides in Fish Sample. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY 2022;70:11804-11812. [PMID: 36070569 DOI: 10.1021/acs.jafc.2c03423] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
45
Azobenzene‐based Photochromic Delivery Vehicles for Ions and Small Molecules. Chemistry 2022;28:e202201902. [DOI: 10.1002/chem.202201902] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2022] [Indexed: 11/07/2022]
46
Lim SG, Seo SE, Park SJ, Kim J, Kim Y, Kim KH, An JE, Kwon OS. Real-time monitoring of serotonin with highly selective aptamer-functionalized conducting polymer nanohybrids. NANO CONVERGENCE 2022;9:31. [PMID: 35829851 PMCID: PMC9279540 DOI: 10.1186/s40580-022-00325-7] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/14/2022] [Accepted: 07/07/2022] [Indexed: 06/01/2023]
47
Ghiasi A, Malekpour A, Mahpishanian S. Aptamer functionalized magnetic metal–organic framework MIL-101(Cr)-NH2 for specific extraction of acetamiprid from fruit juice and water samples. Food Chem 2022;382:132218. [DOI: 10.1016/j.foodchem.2022.132218] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2021] [Revised: 01/15/2022] [Accepted: 01/19/2022] [Indexed: 11/30/2022]
48
Iwano N, Adachi T, Aoki K, Nakamura Y, Hamada M. Generative aptamer discovery using RaptGen. NATURE COMPUTATIONAL SCIENCE 2022;2:378-386. [PMID: 38177576 PMCID: PMC10766510 DOI: 10.1038/s43588-022-00249-6] [Citation(s) in RCA: 17] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/13/2021] [Accepted: 04/21/2022] [Indexed: 01/06/2024]
49
Yang LF, Kacherovsky N, Panpradist N, Wan R, Liang J, Zhang B, Salipante SJ, Lutz BR, Pun SH. Aptamer Sandwich Lateral Flow Assay (AptaFlow) for Antibody-Free SARS-CoV-2 Detection. Anal Chem 2022;94:7278-7285. [PMID: 35532905 PMCID: PMC9112978 DOI: 10.1021/acs.analchem.2c00554] [Citation(s) in RCA: 16] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2022] [Accepted: 04/10/2022] [Indexed: 12/17/2022]
50
Liu X, Zhao Y, Ding Y, Wang J, Liu J. Stabilization of Gold Nanoparticles by Hairpin DNA and Implications for Label-Free Colorimetric Biosensors. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2022;38:5542-5549. [PMID: 35446580 DOI: 10.1021/acs.langmuir.2c00119] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
PrevPage 1 of 12 123451112Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA