1
|
Šimunović L, Čekalović Agović S, Marić AJ, Bačić I, Klarić E, Uribe F, Meštrović S. Color and Chemical Stability of 3D-Printed and Thermoformed Polyurethane-Based Aligners. Polymers (Basel) 2024; 16:1067. [PMID: 38674987 PMCID: PMC11054520 DOI: 10.3390/polym16081067] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2024] [Revised: 04/10/2024] [Accepted: 04/10/2024] [Indexed: 04/28/2024] Open
Abstract
The significant rise in the use of clear aligners for orthodontic treatment is attributed to their aesthetic appeal, enhancing patient appearance and self-confidence. The aim of this study is to evaluate the aligners' response to common staining agents (coffee, black tea, Coca-Cola, and Red Bull) in color and chemical stability. Polyurethane-based thermoformed and 3D-printed aligners from four brands were exposed to common beverages to assess color change using a VITA Easyshade compact colorimeter after 24 h, 48 h, 72 h, and 7 days, as well as chemical stability using ATR-FTIR spectroscopy. The brand, beverage, and manufacturing method significantly influence color stability. ATR-FTIR analysis revealed compositional differences, with variations in response to beverage exposure affecting the integrity of polymer bonds. Color change analysis showed coffee as the most potent staining agent, particularly affecting Tera Harz TC85 aligners, while ClearCorrect aligners exhibited the least susceptibility. 3D-printed aligners showed a greater color change compared to thermoformed ones. Aligners with a PETG outer layer are more resistant to stains and chemical alterations than those made of polyurethane. Additionally, 3D-printed polyurethane aligners stain more than thermoformed ones. Therefore, PETG-layered aligners are a more reliable choice for maintaining the aesthetic integrity of aligners.
Collapse
Affiliation(s)
- Luka Šimunović
- Department of Orthodontics, School of Dental Medicine, University of Zagreb, 10000 Zagreb, Croatia;
| | | | - Antun Jakob Marić
- Faculty of Mechanical Engineering and Naval Architecture, University of Zagreb, 10000 Zagreb, Croatia;
| | - Ivana Bačić
- Forensic Science Centre “Ivan Vučetić”, Ministry of the Interior, 10000 Zagreb, Croatia;
| | - Eva Klarić
- Department of Endodontics and Restorative Dentistry, School of Dental Medicine, University of Zagreb, 10000 Zagreb, Croatia;
| | - Flavio Uribe
- Department of Orthodontics, School of Dental Medicine, University of Connecticut, Farmington, CT 06030, USA;
| | - Senka Meštrović
- Department of Orthodontics, School of Dental Medicine, University of Zagreb, 10000 Zagreb, Croatia;
| |
Collapse
|
2
|
Cen X, Pan X, Wang R, Huang X, Zhao Z. The complex of tannic acid and cetylpyridinium chloride: An antibacterial and stain-removal cleaner for aligners. Am J Orthod Dentofacial Orthop 2024; 165:173-185. [PMID: 37906245 DOI: 10.1016/j.ajodo.2023.08.012] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2022] [Revised: 08/01/2023] [Accepted: 08/01/2023] [Indexed: 11/02/2023]
Abstract
INTRODUCTION Effective aligner hygiene is recognized as an important part of orthodontic treatments and oral hygiene. However, there is no effective cleansing method for removable aligners. METHODS In this study, we incorporated tannic acid (TA) with cetylpyridinium chloride (CPC) to develop the TA-CPC complex. The antibacterial properties of 15.8 mg/mL TA-CPC against Escherichia coli and Staphylococcus aureus were evaluated in vitro, which were compared with 5.1 mg/mL TA, 10.7 mg/mL CPC, a commercial denture cleansing solution (YA; 15 mg/mL), and water. As for the assessment of stain-removal ability, the aligners stained by coffee were soaked in cleansing solutions, and the color changes (ΔE∗) were calculated on the basis of the CIE L∗a∗b∗ color system, and the National Bureau of Standards system was used for the clinical interpretation of the color change. Atomic force microscope examination, tensile property assessment, and wavelength dispersive x-ray fluorescence analysis were performed to investigate the material compatibility of TA-CPC, and Cell Counting Kit-8 assay and live/dead assay were used to test the cytotoxicity of TA-CPC. RESULTS The results showed that TA-CPC had a positive zeta-potential, and cation-π interaction changed the chemical environments of the phenyl group in TA-CPC, resulting in greater inhibition zones of S. aureus and E. coli than other cleaners. The quantification of the biofilm biomass and the fluorescent intensities also reflected that the TA-CPC solution exhibited better antibacterial ability. As for the ability of stain removal, ΔE∗ value of group TA-CPC was 2.84 ± 0.55, whereas those of stained aligners immersed with deionized distilled water, TA, YA, and CPC were 10.26 ± 0.04, 9.54 ± 0.24, 5.93 ± 0.36, and 4.69 ± 0.35, respectively. The visual inspection and National Bureau of Standards ratings also showed that the color of stained aligners cleansed by TA-CPC was much lighter than those of the other groups. Meanwhile, TA-CPC had good compatibility with the aligner material and cells. CONCLUSIONS TA-CPC is a promising strategy to inhibit the formation of biofilms and remove the stains on the aligners safely, which may disinfect the aligners to improve oral health and help keep the transparent appearances of aligners without impacting the morphology and mechanical properties.
Collapse
Affiliation(s)
- Xiao Cen
- State Key Laboratory of Oral Diseases and National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, China
| | - Xuefeng Pan
- State Key Laboratory of Oral Diseases and National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, China
| | - Rong Wang
- Zhejiang International Scientific and Technological Cooperative Base of Biomedical Materials and Technology, Zhejiang Engineering Research Center for Biomedical Materials, Cixi Institute of Biomedical Engineering, Ningbo Institute of Materials Technology and Engineering, Chinese Academy of Sciences, Ningbo, China.
| | - Xinqi Huang
- State Key Laboratory of Oral Diseases and National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, China.
| | - Zhihe Zhao
- State Key Laboratory of Oral Diseases and National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, China.
| |
Collapse
|
3
|
Nicita F, D'Amico C, Filardi V, Spadaro D, Aquilio E, Mancini M, Fiorillo L. Chemical-Physical Characterization of PET-G-Based Material for Orthodontic Use: Preliminary Evaluation of micro-Raman Analysis. Eur J Dent 2024; 18:228-235. [PMID: 37247624 PMCID: PMC10959632 DOI: 10.1055/s-0043-1764424] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/31/2023] Open
Abstract
OBJECTIVES Orthodontic treatment with clear thermoplastic aligners is in great demand by patients especially for aesthetics. Any alterations in the chemical composition of the thermoplastic material for aligners, subjected to the oral environment and exposure to various commonly used substances, could influence the desired orthodontic movement decreasing the predictability of the treatment. The objective of this study was to determine the chemical-physical characterization by micro-Raman spectroscopy of a thermoplastic material based on polyethylene terephthalate glycol (PET-G) used for the manufacture of Lineo aligners (Micerium Lab, Avegno, Italy) subjected to different staining beverages and cleaning agents. MATERIALS AND METHODS Twenty-two thermoformed PET-G samples were immersed to various substances of daily use for 10 and 15 days (coffee, tea, Coca-Cola, red wine, colloidal silver disinfectant, nicotine, artificial saliva, cigarette smoke, and different combinations of saliva with some of the previous solutions). Subsequently, the chemical-physical characterization was investigated by micro-Raman spectroscopy. RESULTS The analysis of the spectra acquired for all the specimens showed no difference in the exposure to the different solvents at 10 and 15 days. Furthermore, having ascertained the heterogeneous surface morphology of the PET-G material due to thermoforming, various deposits were present on all the samples whose consistency and concentration depended on the substance used. CONCLUSION The spectroscopic investigations have provided a precise and detailed analysis of the qualitative and structural data of the PET-G material under examination. No significant structural modifications of the thermoplastic polymer were found after immersion in different solutions in the exposure times adopted.
Collapse
Affiliation(s)
- Fabiana Nicita
- Department of Biomedical and Dental Sciences and Morphofunctional Imaging, University of Messina, via Consolare Valeria, Messina, Italy
| | - Cesare D'Amico
- Department of Biomedical and Dental Sciences and Morphofunctional Imaging, University of Messina, via Consolare Valeria, Messina, Italy
| | - Vincenzo Filardi
- D.A. Research and Internationalization, University of Messina, Via Consolato del mare 41, Messina, Italy
| | | | | | - Maura Mancini
- Department of Biomedical and Dental Sciences and Morphofunctional Imaging, University of Messina, via Consolare Valeria, Messina, Italy
| | - Luca Fiorillo
- Department of Biomedical and Dental Sciences and Morphofunctional Imaging, University of Messina, via Consolare Valeria, Messina, Italy
- Multidisciplinary Department of Medical-Surgical and Dental Specialties, University of Campania Luigi Vanvitelli, Naples, Italy
| |
Collapse
|
4
|
Camenisch L, Polychronis G, Panayi N, Makou O, Papageorgiou SN, Zinelis S, Eliades T. Effect of printing orientation on mechanical properties of 3D-printed orthodontic aligners. J Orofac Orthop 2024:10.1007/s00056-023-00511-0. [PMID: 38277054 DOI: 10.1007/s00056-023-00511-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2023] [Accepted: 12/07/2023] [Indexed: 01/27/2024]
Abstract
PURPOSE The purpose of this study was to assess differences in the fundamental mechanical properties of resin-made three-dimensional (3D) printed orthodontic aligners according to the printing orientation. METHODS Twenty resin 3D-printed dumbbell-shaped specimens and 20 orthodontic aligners were fabricated and postcured in nitrogen. Half of the specimens and aligners were built in horizontal (H), the other half in vertical (V) directions. The dumbbell-shaped specimens were loaded in a tensile testing machine, while parts of the aligners were embedded in acrylic resin, ground, polished, and then underwent instrumented indentation testing (IIT). Mechanical properties that were assessed included the yield strength (YS), breaking strength (BS), plastic strain (ε), Martens hardness (HM), indentation modulus (EIT), elastic index (ηIT), and indentation relaxation (RIT). Data were analyzed statistically with independent t‑tests or Mann-Whitney tests at α = 5%. RESULTS No significant differences were found between specimens or aligners printed either in a horizontal or a vertical direction (P > 0.05 in all instances). Overall, the 3D-printed aligners showed acceptable mechanical propertied in terms of YS (mean 19.2 MPa; standard deviation [SD] 1.7 MPa), BS (mean 19.6 MPa; SD 1.2 MPa), ε (mean 77%; SD 11%), HM (median 89.0 N/mm2; interquartile range [IQR] 84.5-90.0 NN/m2), EIT (median 2670.5 MPa; IQR 2645.0-2726.0 MPa), ηIT (median 27.5%; IQR 25.9-28.1%), and RIT (mean 65.1%; SD 3.5%). CONCLUSION Printing direction seemed to have no effect on the mechanical properties of 3D-printed resin aligners, which are promising for orthodontic use.
Collapse
Affiliation(s)
- Lukas Camenisch
- Clinic of Orthodontics and Pediatric Dentistry, Center for Dental Medicine, University of Zurich, Plattenstr. 11, 8032, Zurich, Switzerland
| | - Georgios Polychronis
- Department of Biomaterials, School of Dentistry, National and Kapodistrian University of Athens, Athens, Greece
| | - Nearchos Panayi
- Department of Dentistry, European University Cyprus, Nicosia, Cyprus
| | - Olga Makou
- Department of Dentistry, European University Cyprus, Nicosia, Cyprus
| | - Spyridon N Papageorgiou
- Clinic of Orthodontics and Pediatric Dentistry, Center for Dental Medicine, University of Zurich, Plattenstr. 11, 8032, Zurich, Switzerland.
| | - Spiros Zinelis
- Department of Biomaterials, School of Dentistry, National and Kapodistrian University of Athens, Athens, Greece
| | - Theodore Eliades
- Clinic of Orthodontics and Pediatric Dentistry, Center for Dental Medicine, University of Zurich, Plattenstr. 11, 8032, Zurich, Switzerland
| |
Collapse
|
5
|
Aldweesh AH, Al-Maflehi NS, AlGhizzi M, AlShayea E, Albarakati SF. Comparison of mechanical properties and color stability of various vacuum-formed orthodontic retainers: An in vitro study. Saudi Dent J 2023; 35:953-959. [PMID: 38107045 PMCID: PMC10724479 DOI: 10.1016/j.sdentj.2023.09.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2023] [Revised: 08/30/2023] [Accepted: 09/04/2023] [Indexed: 12/19/2023] Open
Abstract
Vacuum-formed retainer (VFR) is the most used retainer due to its higher aesthetic properties and lower cost, their mechanical properties of are important in determining the stability and long-term use of appliances made out of them. AIM This study aimed to evaluate and compare the flexural modulus, surface hardness, and color stability of three different VFR materials. METHODS Three different VFR materials, namely Duran, Keystone, and Zendura, of 1 mm thickness, were tested after thermoforming for flexural modulus, hardness, and color stability. They were formed over a stainless-steel model of 12 mm diameter and 6 mm height. RESULTS There were significant statistical differences (p = 0.000) in the flexural modulus and hardness of the three materials. Regarding color stability, Zendura exhibited significantly higher ΔE* values than Keystone and Duran (p < 0.05). CONCLUSIONS Zendura had the highest flexural modulus and hardness compared with Duran and Keystone; however, it is more susceptible to color change compared to the other tested materials.
Collapse
Affiliation(s)
- Aljazi H. Aldweesh
- Division of Orthodontics, Department of Pediatric Dentistry and Orthodontics, College of Dentistry, King Saud University, Riyadh, Saudi Arabia
| | - Nassr S. Al-Maflehi
- Periodontics and Community Dentistry, College of Dentistry, King Saud University, Saudi Arabia
| | | | - Eman AlShayea
- Division of Orthodontics, Department of Pediatric Dentistry and Orthodontics, College of Dentistry, King Saud University, Riyadh, Saudi Arabia
| | - Sahar F. Albarakati
- Division of Orthodontics, Department of Pediatric Dentistry and Orthodontics, College of Dentistry, King Saud University, Riyadh, Saudi Arabia
| |
Collapse
|
6
|
Koletsi D, Panayi N, Laspos C, Athanasiou AE, Zinelis S, Eliades T. In vivo aging-induced surface roughness alterations of Invisalign ® and 3D-printed aligners. J Orthod 2023; 50:352-360. [PMID: 36573484 PMCID: PMC10693732 DOI: 10.1177/14653125221145948] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2022] [Revised: 11/23/2022] [Accepted: 11/30/2022] [Indexed: 12/03/2023]
Abstract
OBJECTIVE To assess the surface roughness of in-house 3D-printed orthodontic aligners compared with Invisalign® appliances, both retrieved as well as in the 'as-received' control status. DESIGN An in vitro study following intra-oral material aging. SETTING AND PARTICIPANTS Twelve clinically used Invisalign® appliances and the same number of 3D-printed aligners, without involvement of attachments, were obtained from a respective number of patients. A similar number of 'as-received' aligners, of each material, were used as control (CON) groups. METHOD Four groups of materials were examined: A = Invisalign® CON; B = Invisalign® used; C = 3D-printed CON; and D = 3D-printed used. Optical profilometry was employed to examine the following surface roughness parameters: amplitude parameters Sa, Sq and Sz and functional parameters Sc and Sv. Descriptive statistics and quantile regression modeling were conducted, and the level of statistical significance was set at α = 0.05. RESULTS Intra-oral exposure of 3D-printed aligners was significantly associated with increase in all tested parameters (P < 0.001 at all occasions). Significant differences were detected in the retrieved 3D-printed aligners compared with Invisalign® retrieved, with the exception of Sz. The respective effect sizes (median differences) were as follows: Sa: 169 nm, 95% confidence interval [CI] = 89-248, P < 0.001; Sq: 315 nm, 95% CI = 152-477, P < 0.001; Sc: 233 nm3/nm2, 95% CI = 131-335, P < 0.001; and Sv: 43 nm3/nm2, 95% CI = 17-68, P = 0.002. CONCLUSION Within the limitations of this study, we concluded that surface roughness differences existed between 3D-printed aligners and Invisalign® in the retrieved status, as well as between the control and retrieved 3D-printed groups.
Collapse
Affiliation(s)
- Despina Koletsi
- Clinic of Orthodontics and Pediatric Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland
| | - Nearchos Panayi
- Clinic of Orthodontics and Pediatric Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland
- Department of Dentistry, School of Medicine, European University Cyprus, Nicosia, Cyprus
- Private practice, Limassol, Cyprus
| | - Christodoulos Laspos
- Department of Dentistry, School of Medicine, European University Cyprus, Nicosia, Cyprus
- Private practice, Limassol, Cyprus
| | | | - Spiros Zinelis
- Department of Biomaterials, School of Dentistry, National and Kapodistrian University of Athens, Athens, Greece
| | - Theodore Eliades
- Clinic of Orthodontics and Pediatric Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland
| |
Collapse
|
7
|
Šimunović L, Jurela A, Sudarević K, Bačić I, Meštrović S. Differential Stability of One-layer and Three-layer Orthodontic Aligner Blends under Thermocycling: Implications for Clinical Durability. Acta Stomatol Croat 2023; 57:286-299. [PMID: 38283309 PMCID: PMC10812913 DOI: 10.15644/asc57/4/1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2023] [Accepted: 12/01/2023] [Indexed: 01/30/2024] Open
Abstract
Objectives To optimize the therapeutic usefulness of aligners, it is crucial to understand how their mechanical properties alter with time. Materials and methods Specimens from four different brands, including Duran+, CA® Pro, Zendura A, and Zendura FLX, were produced for material testing of thermoplastic orthodontic aligners (TOA) using dimensions measuring 4mm x 10mm. Each brand's 24 samples were split into three groups as follows: G1 being thermoformed, G2 being thermoformed and underwent 500 thermocycles (simulating 7 days), and G3 being thermoformed and underwent 1000 thermocycles (simulating 14 days). Surface roughness, modulus of elasticity in bending, and spectrophotometry were used to assess the effect of aging on TOAs. Results After 1000 thermocycles, Duran+ had the highest modulus of elasticity and differed statistically from all other groups. The intragroup comparison showed that only Duran+'s elastic modulus significantly changed after 1000 thermocycles in comparison with the control group. Surface roughness values (Ra), did not statistically differ among brands or thermocycling group measures. The change in chemical properties was not significant in any brand. Conclusion One-layer PETG (Duran+) failed to demonstrate stability after in vitro aging, thus suggesting that clinicians should be aware of the change in mechanical properties when using one-layer PETG (Duran +) in a 2 weeks regime.
Collapse
Affiliation(s)
- Luka Šimunović
- Department of Orthodontics, School of Dental Medicine, University of Zagreb, Gundulićeva 5, 10000 Zagreb, Croatia
| | | | | | - Ivana Bačić
- Forensic Science Centre "Ivan Vučetić", Ministry of the Interior, Ilica 351, 10000 Zagreb, Croatia
| | - Senka Meštrović
- Department of Orthodontics, School of Dental Medicine, University of Zagreb, Gundulićeva 5, 10000 Zagreb, Croatia
| |
Collapse
|
8
|
Chen SM, Huang TH, Ho CT, Kao CT. Force degradation study on aligner plates immersed in various solutions. J Dent Sci 2023; 18:1845-1849. [PMID: 37799905 PMCID: PMC10547977 DOI: 10.1016/j.jds.2023.06.017] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2023] [Revised: 06/18/2023] [Indexed: 10/07/2023] Open
Abstract
Background/purpose The strength of aligners themselves has a high decay rate and is susceptible to accelerated degradation in the environment. The purpose of this study was to compare three types of invisible aligner films after being immersed in coffee, tea, cola, and red wine for seven days and to evaluate the changes in their strengths. Materials and methods Three types of invisible aligner plates with a thickness of 0.75 mm, i.e., Duran T (polyethylene terephthalate glycol, PETG), Biolon (polyethylene terephthalate, PET), and Zendura FLX (polyurethane, PU), were soaked in artificial saliva and four drinks (coffee, tea, cola, red wine) for 1, 4, and 7 days. The strength test was performed by using the three-point bending test method. The residual strength ratio for the same type of invisible correction film at the same time was separately recorded. The independent t-test was used to indicate significant differences at P < 0.05. Results The Biolon invisible correction film soaked in cola, red wine and artificial saliva showed significant differences on the 1st and 4th days (P < 0.05). The Duran T invisible correction film soaked in coffee and artificial saliva showed significant differences on the first day (P < 0.05). The Zendura FLX invisible correction film had a waterproof layer on the surface, and there was no significant difference between soaking in any drink and soaking in saliva (P > 0.05). Conclusion Invisible correction films with different ingredients soaked in solutions show a strength decay phenomenon, except for those with TPU ingredients.
Collapse
Affiliation(s)
- Shou-Min Chen
- School of Dentistry, College of Oral Medicine, Chung Shan Medical University, Taichung, Taiwan
- Orthodontic Department, Chung Shan Medical University Hospital, Taichung, Taiwan
| | - Tsui-Hsein Huang
- School of Dentistry, College of Oral Medicine, Chung Shan Medical University, Taichung, Taiwan
- Dental Department, Chung Shan Medical University Hospital, Taichung, Taiwan
| | - Chun-Te Ho
- School of Dentistry, College of Oral Medicine, Chung Shan Medical University, Taichung, Taiwan
- Orthodontic Department, Chung Shan Medical University Hospital, Taichung, Taiwan
| | - Chia-Tze Kao
- Orthodontic Department, Chung Shan Medical University Hospital, Taichung, Taiwan
- Dental Department, Chung Shan Medical University Hospital, Taichung, Taiwan
| |
Collapse
|
9
|
Lira LF, Otero Amaral Vargas E, Moreira da Silva E, Nunes da Silva Meirelles Dória Maia J, Elzubair A, Siqueira de Morais L, Alvaro de Souza Camargo S, Serra G, Gomes de Souza MM. Effect of oral exposure on chemical, physical, mechanical, and morphologic properties of clear orthodontic aligners. Am J Orthod Dentofacial Orthop 2023; 164:e51-e63. [PMID: 37330727 DOI: 10.1016/j.ajodo.2023.05.015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2022] [Revised: 05/01/2023] [Accepted: 05/01/2023] [Indexed: 06/19/2023]
Abstract
INTRODUCTION The dental industry is heavily committed to developing more esthetic solutions for orthodontic treatments. Invisalign is a system of transparent orthodontic aligners introduced as an alternative to conventional orthodontic fittings with brackets and metal wires. This study aimed to assess the chemical, physical, mechanical and morphologic changes in these polymeric aligners after exposure to the oral environment. METHODS Twenty-four Invisalign orthodontic aligners were equally divided into 2 groups: an in vivo aged group in which patients used aligners for 14 days and the reference group, unexposed to the oral environment. Different experimental techniques were used to study the chemical structure, the color changes and translucency, the density and subsequent volume of the aligners, mechanical properties, surface roughness, morphology and elemental composition. The data were subjected to several statistical analyses. RESULTS Clear orthodontic aligners exhibit chemical stability but undergo a statistically significant optical change in color and translucency. There was a gradual increase in the water absorption rate and the dimensional variation of the polymer, indicating a strong correlation among these factors. The mechanical properties of the polymer showed a statistically significant decrease in its elastic modulus and hardness. There was a slight tendency toward increased surface roughness of the material, but no statistical differences were found between reference and aged groups. The surface morphology of the used aligners demonstrates microcracks, distortions and biofilm formation. CONCLUSION Intraoral aging adversely affected the physical, mechanical, and morphologic properties of the Invisalign appliance.
Collapse
Affiliation(s)
- Larine Ferreira Lira
- Department of Pediatric Dentistry and Orthodontics, Federal University of Rio de Janeiro, Rio de Janeiro, Brazil
| | - Eduardo Otero Amaral Vargas
- Department of Pediatric Dentistry and Orthodontics, Federal University of Rio de Janeiro, Rio de Janeiro, Brazil
| | - Eduardo Moreira da Silva
- Analytical Laboratory of Restorative Biomaterials-LABiom-R, School of Dentistry, Federal Fluminense University, Niterói, Brazil
| | | | - Amal Elzubair
- Metallurgical and Materials Engineering Program, Alberto Luiz Coimbra Institute for Graduate Studies and Research in Engineering (COPPE), Federal University of Rio de Janeiro, Rio de Janeiro, Brazil
| | - Liliane Siqueira de Morais
- Department of Pediatric Dentistry and Orthodontics, Federal University of Rio de Janeiro, Rio de Janeiro, Brazil
| | - Sérgio Alvaro de Souza Camargo
- Metallurgical and Materials Engineering Program, Alberto Luiz Coimbra Institute for Graduate Studies and Research in Engineering (COPPE), Federal University of Rio de Janeiro, Rio de Janeiro, Brazil; Nanotechnology Engineering Program, COPPE, Federal University of Rio de Janeiro, Rio de Janeiro, Brazil
| | - Glaucio Serra
- Department of Specific Formation, Federal Fluminense University, Nova Friburgo, Brazil
| | | |
Collapse
|
10
|
Porojan L, Toma FR, Bîrdeanu MI, Vasiliu RD, Matichescu A. Topographical and Optical Characteristics of Thermoplastic Dental Appliances Materials Related to Water Sorption. J Funct Biomater 2023; 14:jfb14040190. [PMID: 37103280 PMCID: PMC10146702 DOI: 10.3390/jfb14040190] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2023] [Revised: 03/22/2023] [Accepted: 03/27/2023] [Indexed: 03/31/2023] Open
Abstract
Clear thermoplastic materials have increased in popularity in the dental field due to their various applications, combination of excellent aesthetics, and good biomechanical behavior, but they may be influenced by different environmental conditions. The purpose of the present study was to assess the topographical and optical characteristics of thermoplastic dental appliances materials relative to water sorption. PET-G polyester thermoplastic materials were evaluated in this study. Related to water uptake and desiccation stages, surface roughness was analyzed, and three-dimensional AFM profiles were generated for nano-roughness measurements. Optical CIE L*a*b* coordinates were recorded and parameters like translucency (TP), contrast ratio for the opacity (CR), and opalescence (OP) were derived. Levels of color changes were achieved. Statistical analyses were performed. Water uptake significantly increases the specific weight of the materials, and after desiccation, the mass decreases. Roughness increased after water immersion as well. Regression coefficients indicated a positive correlation between TP and a* and between OP and b*. Studied PET-G materials have a different behavior to water exposure, but for all their specific weight, they increased significantly within the first 12 h. It is accompanied by an increase in the roughness values, even if they continue to be kept below the critical mean surface roughness. On nano-level, 3D images show an increase in inhomogeneity in the network structure of particles. Slight color changes were registered.
Collapse
Affiliation(s)
- Liliana Porojan
- Department of Dental Prostheses Technology (Dental Technology), Center for Advanced Technologies in Dental Prosthodontics, Faculty of Dental Medicine, Victor Babes University of Medicine and Pharmacy Timisoara, Eftimie Murgu Square No. 2, 300041 Timisoara, Romania
- Correspondence:
| | - Flavia Roxana Toma
- Department of Dental Prostheses Technology (Dental Technology), Center for Advanced Technologies in Dental Prosthodontics, Faculty of Dental Medicine, Victor Babes University of Medicine and Pharmacy Timisoara, Eftimie Murgu Square No. 2, 300041 Timisoara, Romania
| | - Mihaela Ionela Bîrdeanu
- National Institute for Research and Development in Electrochemistry and Condensed Matter, A. Păunescu Podeanu Str. No. 144, 300569 Timisoara, Romania
| | - Roxana Diana Vasiliu
- Department of Dental Prostheses Technology (Dental Technology), Center for Advanced Technologies in Dental Prosthodontics, Faculty of Dental Medicine, Victor Babes University of Medicine and Pharmacy Timisoara, Eftimie Murgu Square No. 2, 300041 Timisoara, Romania
| | - Anamaria Matichescu
- Department of Preventive, Community Dentistry and Oral Health, Center for Advanced Technologies in Dental Prosthodontics, Faculty of Dental Medicine, Victor Babes University of Medicine and Pharmacy Timisoara, Eftimie Murgu Square No. 2, 300041 Timisoara, Romania
| |
Collapse
|
11
|
Quinzi V, Orilisi G, Vitiello F, Notarstefano V, Marzo G, Orsini G. A spectroscopic study on orthodontic aligners: First evidence of secondary microplastic detachment after seven days of artificial saliva exposure. THE SCIENCE OF THE TOTAL ENVIRONMENT 2023; 866:161356. [PMID: 36603638 DOI: 10.1016/j.scitotenv.2022.161356] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/25/2022] [Revised: 12/20/2022] [Accepted: 12/30/2022] [Indexed: 06/17/2023]
Abstract
Clear orthodontic aligners have recently seen increasing popularity. The thermoplastic materials present several advantages, even if it is known that all plastic products can be subjected to environmental and mechanical degradation, leading to the release of microplastics (MPs). Their ingestion could cause oxidative stress and inflammatory lesions. This study aims to evaluate the potential detachment of MPs by clear aligners due to mechanical friction simulated with a 7-day protocol in artificial saliva. The study was performed on orthodontic clear aligners from different manufacturers: Alleo (AL); FlexiLigner (FL); F22 Aligner (F22); Invisalign® (INV); Lineo (LIN); Arc Angel (ARC), and Ortobel Aligner (OR). For each group, two aligners were immersed in artificial saliva for 7 days and stirred for 5 h/day, simulating the physiological teeth mechanical friction. After 7 days, the artificial saliva was filtered; then, filters were analyzed by Raman Microspectroscopy (RMS) and Scanning Electron Microscopy (SEM), respectively to chemically identify the polymeric matrix and to measure the number and size of the detected MPs. RMS spectra revealed that AL, FL, LIN, ARC, and OR aligners were composed by polyethylene terephthalate, while F22 and INV ones by polyurethane. SEM analysis showed that the highest number of MPs was found in ARC and the lowest in INV (p < 0.05). As regards MPs' size, no statistically significant difference was found among groups, with most MPs ranging from 5 to 20 μm. Noteworthy, a highly significant correlation (p < 0.0001) was highlighted between the distribution of MPs size and the different typologies of aligners. This in vitro study highlighted for the first time the detachment of MPs from clear aligners due to mechanical friction. This evidence may represent a great concern in the clinical practice since it could impact human general health.
Collapse
Affiliation(s)
- Vincenzo Quinzi
- Università degli Studi dell'Aquila, Dipartimento di Medicina Clinica, Sanità Pubblica, Scienze della Vita e dell'Ambiente, Piazza Salvatore Tommasi, 67100 L'Aquila, Italy
| | - Giulia Orilisi
- Università Politecnica delle Marche, Dipartimento di Scienze Cliniche Specialistiche ed Odontostomatologiche, Via Tronto 10, 60126 Ancona, Italy
| | - Flavia Vitiello
- Università Politecnica delle Marche, Dipartimento di Scienze Cliniche Specialistiche ed Odontostomatologiche, Via Tronto 10, 60126 Ancona, Italy
| | - Valentina Notarstefano
- Università Politecnica delle Marche, Dipartimento di Scienze della Vita e dell'Ambiente, Via Brecce Bianche, 60131 Ancona, Italy
| | - Giuseppe Marzo
- Università degli Studi dell'Aquila, Dipartimento di Medicina Clinica, Sanità Pubblica, Scienze della Vita e dell'Ambiente, Piazza Salvatore Tommasi, 67100 L'Aquila, Italy
| | - Giovanna Orsini
- Università Politecnica delle Marche, Dipartimento di Scienze Cliniche Specialistiche ed Odontostomatologiche, Via Tronto 10, 60126 Ancona, Italy.
| |
Collapse
|
12
|
Venkatasubramanian P, Jerome MS, Ragunanthanan L, Maheshwari U, Vijayalakshmi D. Color stability of aligner materials on exposure to indigenous food products: An in-vitro study. J Dent Res Dent Clin Dent Prospects 2022; 16:221-228. [PMID: 37560499 PMCID: PMC10407867 DOI: 10.34172/joddd.2022.035] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2022] [Accepted: 12/03/2022] [Indexed: 08/11/2023] Open
Abstract
Background In the recent day, there has been an exponential growth in the usage of clear aligners for orthodontic treatment. As with any removable appliance, the compliance of patients to remove it during ingestion of food is, at times, poor. Thus, the stability of the clear aligner to be "clear" becomes questionable. This in-vitro study examined how the clear aligners changed colour on exposure to various indigenous food products used in everyday life. Methods Aligners from 5 different companies (K Line, Clearbite Aligners, The Aligner Company, iAligners and MaxDent CA Digital) were exposed for 12 hours and 24 hours to various indigenous substances (tea, green tea, coffee, turmeric, saffron and Kashmiri red chili powder) and a control solution (distilled water) in-vitro. The color change was assessed with the help of VITA Easyshade compact colorimeter based on Commission Internationale de I'Eclairage L*a*b* color system. Values were then modified to NBS units for clinical relevance. Results The hue of the transparent aligners was noticed to change in a statistically meaningful way when exposed to turmeric, saffron, Kashmiri red chili powder and coffee in decreasing order and mild color change in tea and green tea at both 12 hours and 24 hours intervals. Conclusion Aligners are prone to color change when exposed to indigenous foods that contain staining properties.
Collapse
Affiliation(s)
- Priyanka Venkatasubramanian
- Department of Orthodontics and Dentofacial Orthopaedics, Meenakshi Ammal Dental College and Hospital, Meenakshi Academy of Higher Education & Research, Mylapore, Chennai, India
| | - Mary Sanjana Jerome
- Department of Orthodontics and Dentofacial Orthopaedics, Meenakshi Ammal Dental College and Hospital, Meenakshi Academy of Higher Education & Research, Mylapore, Chennai, India
| | - Lokamithra Ragunanthanan
- Department of Orthodontics and Dentofacial Orthopaedics, Meenakshi Ammal Dental College and Hospital, Meenakshi Academy of Higher Education & Research, Mylapore, Chennai, India
| | - Uma Maheshwari
- Department of Orthodontics and Dentofacial Orthopaedics, Meenakshi Ammal Dental College and Hospital, Meenakshi Academy of Higher Education & Research, Mylapore, Chennai, India
| | - Devaki Vijayalakshmi
- Department of Orthodontics and Dentofacial Orthopaedics, Meenakshi Ammal Dental College and Hospital, Meenakshi Academy of Higher Education & Research, Mylapore, Chennai, India
| |
Collapse
|
13
|
Iliadi A, Enzler V, Polychronis G, Peltomaki T, Zinelis S, Eliades T. Εffect of cleansers on the composition and mechanical properties of orthodontic aligners in vitro. Prog Orthod 2022; 23:54. [PMID: 36517652 PMCID: PMC9751251 DOI: 10.1186/s40510-022-00449-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2022] [Accepted: 11/09/2022] [Indexed: 12/23/2022] Open
Abstract
BACKGROUND The aim of the study was to investigate the effect of three aligner cleaners on the composition and mechanical properties of two types of orthodontic aligners. MATERIALS AND METHODS The cleaners tested were two alkaline peroxide solutions (Retainer Brite-RB; Retainer Cleaner-RC) and one peroxide-free (Steraligner-ST) and the aligners Clear Aligner (C, polyester) and Invisalign (I, polyester-urethane). The aligners were immersed in the cleaner solutions as instructed every day (15 min for RB, RC; 5 min for ST) for a two-week period. The acidity of the solutions was tested with a pH meter. The changes in the chemical composition of the aligners were studied by attenuated total-reflection Fourier transform infrared spectrometry (ATR-FTIR), while Instrumented Indentation Testing (IIT) was used for assessment of changes in Martens Hardness (HM), modulus (EIT), elastic index (nIT) and relaxation (RIT). RESULTS RB and RC were weakly acidic (pH = 6.3), whereas ST was mildly acidic (pH = 4.8). The ATR-FTIR analysis demonstrated evidence of acidic hydrolysis of C in ST and I in RB. The IIT-derived properties of I were not affected by the cleaners. However, for C a significant change was found in HM (all cleaners), nIT (all cleaners) and RIT (RB, ST). Although the chemical changes support a hydrolytic material deterioration, the results of mechanical properties may interfere with the material residual stresses during fabrication. CONCLUSIONS Caution should be exerted in the selection of aligner cleaners. The mild acidic cleanser was more aggressive to the polyester, whereas an alkaline peroxide to the polyester-urethane aligner.
Collapse
Affiliation(s)
- Anna Iliadi
- grid.5216.00000 0001 2155 0800Department of Biomaterials, School of Dentistry, National and Kapodistrian University of Athens, Athens, Greece
| | - Vera Enzler
- grid.7400.30000 0004 1937 0650Clinic of Orthodontics and Pediatric Dentistry, Center of Dental Medicine, University of Zurich, Plattenstrasse 11, 8032 Zurich, Switzerland
| | - Georgios Polychronis
- grid.5216.00000 0001 2155 0800Department of Biomaterials, School of Dentistry, National and Kapodistrian University of Athens, Athens, Greece
| | - Timo Peltomaki
- grid.502801.e0000 0001 2314 6254Department of Oral and Maxillofacial Diseases, Tampere University Hospital, Tampere, Finland Faculty of Medicine and Health Technology, Tampere University, Tampere, Finland ,grid.410705.70000 0004 0628 207XDepartment of Oral and Maxillofacial Diseases, Kuopio University Hospital, Kuopio, Finland ,grid.9668.10000 0001 0726 2490Faculty of Health Sciences, Institute of Dentistry, University of Eastern Finland, Kuopio, Finland
| | - Spiros Zinelis
- grid.5216.00000 0001 2155 0800Department of Biomaterials, School of Dentistry, National and Kapodistrian University of Athens, Athens, Greece
| | - Theodore Eliades
- grid.7400.30000 0004 1937 0650Clinic of Orthodontics and Pediatric Dentistry, Center of Dental Medicine, University of Zurich, Plattenstrasse 11, 8032 Zurich, Switzerland
| |
Collapse
|
14
|
Advances in orthodontic clear aligner materials. Bioact Mater 2022; 22:384-403. [PMID: 36311049 PMCID: PMC9588987 DOI: 10.1016/j.bioactmat.2022.10.006] [Citation(s) in RCA: 32] [Impact Index Per Article: 16.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2022] [Revised: 10/05/2022] [Accepted: 10/06/2022] [Indexed: 11/24/2022] Open
Abstract
Rapid technological improvements in biomaterials, computer-aided design (CAD) and manufacturing (CAM) have endorsed clear aligner therapy (CAT) as a mainstay of orthodontic treatment, and the materials employed for aligner fabrication play an all-important role in determining the clinical performance of clear aligners. This narrative review has attempted to comprehensively encompass the entire gamut of materials currently used for the fabrication of clear aligners and elucidate their characteristics that are crucial in determining their performance in an oral environment. Historical developments and current protocols in aligner fabrication, features of contemporary bioactive materials, and emerging trends related to CAT are discussed. Advances in aligner material chemistry and engineering possess the potential to bring about radical transformations in the therapeutic applications of CAT; in the absence of which, clear aligners would continue to underperform clinically, due to their inherent biomechanical constraints. Finally, while innovations in aligner materials such as shape memory polymers, direct three-dimensional (3D) printed clear aligners and bioactive materials combined with clear aligner materials are essential to further advance the applications of CAT; increased awareness of environmental responsibilities among aligner manufacturers, aligner prescribing clinicians and aligner users is essential for better alignment of our climate change goals towards a sustainable planet.
Collapse
|
15
|
Susarchick L, Virji I, Viana G, Mahmoud M, Allareddy V, Gruber M, Lukic H, Megremis S, Atsawasuwan P. The Effects of Staining and Cleaning on the Color and Light Transmittance Changes of a Copolyester Retainer Material with Different Surface Textures. MATERIALS (BASEL, SWITZERLAND) 2022; 15:ma15196808. [PMID: 36234148 PMCID: PMC9570909 DOI: 10.3390/ma15196808] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/22/2022] [Revised: 09/20/2022] [Accepted: 09/26/2022] [Indexed: 05/27/2023]
Abstract
This study evaluated the efficacy of different cleaning methods with respect to changes in the color and light transmittance of both rough and smooth thermoformed, copolyester retainer specimens, after staining in different solutions. Four hundred copolyester sheets (Essix ACE) specimens were fabricated over molds with different surface textures, smooth and rough. The specimens were stained in four different solutions (n = 100 per solution) over 28 days; then, each of the four groups of 100 stained specimens was sub-divided into five groups of 20 specimens and subjected to a different destaining solution. The specimens were sub-divided with half subjected to an additional ultrasonic cleaning procedure. Light transmittance and color changes were analyzed using a spectrometer/integrating sphere assembly and a spectrophotometer. Mean difference comparisons were performed using appropriate statistical tests at p = 0.05. All five destaining solutions proved to be effective at removing coffee and tea stains. The surface roughness of the retainer material plays a significant role in the ability of cleaning solutions to remove stains, demonstrating a greater effect on cleaning rough specimens with respect to improvements in light transmittance and greater changes in color. Additionally, an ultrasonic cleaning unit generally enhanced the ability of all five solutions to clean the tea-stained specimens. However, the enhancements were only significant for light transmittance.
Collapse
Affiliation(s)
- Laurie Susarchick
- Department of Orthodontics, University of Illinois Chicago, Chicago, IL 60612, USA
| | - Insia Virji
- Department of Orthodontics, University of Illinois Chicago, Chicago, IL 60612, USA
| | - Grace Viana
- Department of Orthodontics, University of Illinois Chicago, Chicago, IL 60612, USA
| | - Mervat Mahmoud
- Department of Orthodontics, University of Illinois Chicago, Chicago, IL 60612, USA
| | | | - Max Gruber
- Dental Materials & Devices Research—American Dental Association, Chicago, IL 60610, USA
| | - Henry Lukic
- Dental Materials & Devices Research—American Dental Association, Chicago, IL 60610, USA
| | - Spiro Megremis
- Dental Materials & Devices Research—American Dental Association, Chicago, IL 60610, USA
| | - Phimon Atsawasuwan
- Department of Orthodontics, University of Illinois Chicago, Chicago, IL 60612, USA
| |
Collapse
|
16
|
Borges L, Castro ACRD, Elias CN, Souza MMGD. Effect of cigarette smoke on aesthetic brackets: an in vitro study. Dental Press J Orthod 2022; 27:e2220365. [PMID: 36074431 PMCID: PMC9439572 DOI: 10.1590/2177-6709.27.4.e2220365.oar] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2020] [Accepted: 04/25/2021] [Indexed: 11/24/2022] Open
Abstract
Objective: The objective of this study was to evaluate the effect of cigarette smoke (CS) on physical and mechanical properties of ceramic, polycarbonate and alumina ceramic brackets. The null hypothesis tested was that aesthetic brackets would not be influenced by CS. Methods: Ninety aesthetic brackets were allocated to three groups (n = 30): ceramic (GCE), polycarbonate (GCO) and alumina ceramic (GPS). Ten samples of each group were assigned to color and surface roughness analysis, performed before (T0) and after (T1) exposure to CS; and twenty samples were allocated into control and experimental groups (n = 10) (not exposed and exposed to CS, respectively) for shear bond strength test (SBS). Exposure to CS followed an adaptation of the method described by Le Mesurier. Colorimetric reading, surface morphology and roughness, SBS and adhesive remnant index (ARI) were assessed. Statistical analysis comprised independent and paired t-tests, ANOVA/Tukey and Fisher’s exact tests (α = 0.05). Results: Changes were observed in brackets’ color (NBS: GCE = 2.4; GCO = 1.9; GPS = 2.1), surface roughness (ΔRa: GCE = 1.1 ± 0.8 µm; GCO = 1.9 ± 1.5µm; GPS = -0.3 ± 0.1 µm / ΔRz: GCE = 1.4 ± 1.0 nm; GPS = -0.5 ± 0.1 nm); and SBS (GPS - experimental = 221.8 ± 48.6 N) after exposure to CS (p< 0.05). Conclusions: Exposure, in vitro, of aesthetic brackets to CS resulted in changes of color to darker and more opaque shades, surface roughness alterations, and higher SBS values. ARI scores were not associated with exposure to CS.
Collapse
Affiliation(s)
- Laura Borges
- Universidade Federal do Rio de Janeiro, Faculdade de Odontologia, Departamento de Ortodontia e Odontopediatria (Rio de Janeiro/RJ, Brazil).,Universidade de São Paulo, Faculdade de Odontologia de Ribeirão Preto (Ribeirão Preto/SP, Brazil)
| | - Amanda Cunha Regal de Castro
- Universidade Federal do Rio de Janeiro, Faculdade de Odontologia, Departamento de Ortodontia e Odontopediatria (Rio de Janeiro/RJ, Brazil)
| | - Carlos Nelson Elias
- Instituto Militar de Engenharia, Laboratório de Biomateriais (Rio de Janeiro/RJ, Brazil)
| | - Margareth Maria Gomes de Souza
- Universidade Federal do Rio de Janeiro, Faculdade de Odontologia, Departamento de Ortodontia e Odontopediatria (Rio de Janeiro/RJ, Brazil)
| |
Collapse
|
17
|
Nowak CM, Othman A, Ströbele DA, von See C. Comparative mechanical testing for different orthodontic aligner materials over time - in vitro study. J Clin Exp Dent 2022; 14:e457-e463. [PMID: 35765355 PMCID: PMC9233917 DOI: 10.4317/jced.59569] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2022] [Accepted: 04/11/2022] [Indexed: 11/08/2022] Open
Abstract
Background The purpose of the present study is to mechanically evaluate and compare the forces over 12 hours on different orthodontic aligners manufactured by Polyethylene terephthalate glycol (PETG).
Material and Methods Twelve orthodontic aligner specimens will be produced by a thermoforming laboratory vacuum machine. All specimens will be divided into two equal groups, group A representing Duran (Scheu Dental GmbH, Iserlohn, Germany) and group B representing Erkodur (Erkodent, Pfalzgrafenweiler, Germany). These specimens will be fabricated via CAD/CAM technology by scanning a Frasaco model (Henry Schein Dental, Gallin, Germany) using D 800 (3Shape, Copenhagen, Denmark) and printed via a Varseo S machine using Varseo ModelWax material (BEGO, Bremen, Germany). Group A specimens are manufactured by a Twinster thermoforming machine (Scheu Dental GmbH, Iserlohn, Germany) while group B is produced using Erkoform thermoforming machine (Erkodent, Pfalzgrafenweiler, Germany). Afterwards, a tooth will be removed from the printed model and replaced by an ivory tooth (Henry Schein Dental, Gallin, Germany) to apply forces at a predicted measured centre of resistance. The universal testing machine Z010 (ZwickRoell, Ulm, Germany) will be used for mechanical testing with 0.3 mm displacement over 12 hours. Statistical analysis was performed using Sigmaplot 13.0 (Systat Software GmbH, Erkrath, Germany). Behaviours over time were analysed using R2-regression analysis (SPSS 26.0, IBM SPSS Statistics, Armonk, USA).
Results There is no statistically significant difference in the maximum force between both groups (p=0.071). The mechanical testing over 12 hours showed cubic properties.
Conclusions The PETG material has no influence on the produced mechanical forces regardless of the manufacturing company. The forces over time showed no tendency towards a lower boundary of force. Key words:Mechanical testing, CAD/CAM, orthodontics, thermoplastic aligner materials.
Collapse
Affiliation(s)
- Clara-Marie Nowak
- Researcher in the digital technologies in dentistry and CAD/CAM department- Danube Private University- Austria
| | - Ahmed Othman
- Assistant Professor, Research Center for Digital Technologies in Dentistry and CAD/CAM, Department of Dentistry, Faculty of Medicine and Dentistry, Danube Private University, 3500 Krems, Austria
| | - Dragan-Alexander Ströbele
- Researcher in the digital technologies in dentistry and CAD/CAM department- Danube Private University- Austria
| | - Constantin von See
- Professor and Director of Research Center for Digital Technologies in Dentistry and CAD/CAM, Department of Dentistry, Faculty of Medicine and Dentistry, Danube Private University, 3500 Krems, Austria
| |
Collapse
|
18
|
Kiatwarawut K, Rokaya D, Sirisoontorn I. Antimicrobial Activity of Various Disinfectants to Clean Thermoplastic Polymeric Appliances in Orthodontics. Polymers (Basel) 2022; 14:polym14112256. [PMID: 35683929 PMCID: PMC9183154 DOI: 10.3390/polym14112256] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2022] [Revised: 05/28/2022] [Accepted: 05/30/2022] [Indexed: 11/16/2022] Open
Abstract
There is a lack of research evidence on the risk–benefits of the various disinfectants in cleaning products and cleansing regimens. This systematic review compared the antimicrobial activity of various chemical disinfectants to disinfect the thermoplastic polymeric appliances in orthodontics. The study was carried out using the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) and Cochrane Handbook of Systematic Reviews of Interventions. An electronic search was conducted on Pubmed, Google Scholar, Scopus, ScienceDirect, and Springer. Two authors independently investigated the risk of bias in duplication. A total of 225 articles were collected. After removing duplicates, 221 articles remained, and after filtering their titles and abstracts, 11 articles met eligibility qualifications remained. Finally, nine articles that met the criteria were selected. It showed that both over-the-counter orthodontic appliance cleaners and applied-chemical disinfectants were effective against bacteria. The duration and frequency of usage guidelines cannot be concluded.
Collapse
|
19
|
Ammann R, Tanner C, Schulz G, Osmani B, Nalabothu P, Töpper T, Müller B. Three-dimensional analysis of aligner gaps and thickness distributions, using hard x-ray tomography with micrometer resolution. J Med Imaging (Bellingham) 2022; 9:031509. [PMID: 36267352 PMCID: PMC9574087 DOI: 10.1117/1.jmi.9.3.031509] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2021] [Accepted: 05/31/2022] [Indexed: 07/02/2024] Open
Abstract
PURPOSE The morphology of a polymer aligner, designed according to an orthodontic treatment plan, determines clinical outcomes. A fundamental element of orthodontic tooth movement with aligner treatment is the fit of the aligner's surface to the individual teeth. Gaps between the aligner and teeth do occur because current aligner fabrication is not capable of completely reproducing the complex anatomy of the individual denture. Our study aims at a quantitative three-dimensional assessment of the fit between optically transparent aligners placed on a polymeric model of the upper dental arch for two thermofoil thicknesses at preselected thermoforming temperatures. APPROACH Using an intraoral scan of a subject's upper dental arch, eight models were printed using a stereolithographic system. A series of eight NaturAligners® was manufactured with a pressure molding process, using thermofoils with thicknesses of 550 and 750 μ m and preselected process temperatures between 110°C and 210°C. These aligners placed on the corresponding models were imaged by an advanced micro computed tomography system. The aligners and the models were segmented to extract the gaps and aligners' local thicknesses as a function of the processing temperature for the two foil thicknesses. RESULTS The results indicate that the aligners show a better fit when the foils are processed at higher temperatures. Nevertheless, processing temperatures can be kept below 150°C, as the gain becomes negligible. Thermal processing reduces the average thickness of the aligners to 60% with respect to the planar starting foil. These thickness distributions demonstrate that the aligners are generally thicker on the occlusal surfaces of molars and premolars but thinner around the incisors and buccal as well as on oral surfaces. CONCLUSIONS Hard x-ray tomography with micrometer resolution is a powerful technique employed to localize the gaps between aligners and teeth, and it also enables film thickness measurements after thermoforming. The thicker film on the occlusal surfaces is most welcome because of aligner abrasion during wear. The NaturAligner® surfaces consist of a 25 - μ m -thin cellulose layer, and thus the microplastics released via abrasion of less than this thickness are expected to be substantially less critical than for other commercially available, optically transparent aligners.
Collapse
Affiliation(s)
- Rémi Ammann
- University of Basel, Biomaterials Science Center, Department of Biomedical Engineering, Allschwil, Switzerland
- University of Basel, Biomaterials Science Center, Department of Clinical Research, Basel, Switzerland
| | - Christine Tanner
- University of Basel, Biomaterials Science Center, Department of Biomedical Engineering, Allschwil, Switzerland
- University of Basel, Biomaterials Science Center, Department of Clinical Research, Basel, Switzerland
| | - Georg Schulz
- University of Basel, Biomaterials Science Center, Department of Biomedical Engineering, Allschwil, Switzerland
- University of Basel, Core Facility Micro- and Nanotomography, Department of Biomedical Engineering, Allschwil, Switzerland
| | - Bekim Osmani
- University of Basel, Biomaterials Science Center, Department of Biomedical Engineering, Allschwil, Switzerland
- University of Basel, Biomaterials Science Center, Department of Clinical Research, Basel, Switzerland
| | - Prasad Nalabothu
- University Hospital Basel, Department of Oral and Craniomaxillofacial Surgery, Basel, Switzerland
- University of Basel, Center for Dental Medicine, Department of Pediatric Oral Health and Orthodontics, Basel, Switzerland
| | - Tino Töpper
- University of Basel, Biomaterials Science Center, Department of Biomedical Engineering, Allschwil, Switzerland
- University of Basel, Biomaterials Science Center, Department of Clinical Research, Basel, Switzerland
| | - Bert Müller
- University of Basel, Biomaterials Science Center, Department of Biomedical Engineering, Allschwil, Switzerland
- University of Basel, Biomaterials Science Center, Department of Clinical Research, Basel, Switzerland
| |
Collapse
|
20
|
Alhendi A, Khounganian R, Ali R, Syed SA, Almudhi A. Structural Conformation Comparison of Different Clear Aligner Systems: An In Vitro Study. Dent J (Basel) 2022; 10:dj10050073. [PMID: 35621526 PMCID: PMC9139589 DOI: 10.3390/dj10050073] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2022] [Revised: 04/25/2022] [Accepted: 04/27/2022] [Indexed: 12/10/2022] Open
Abstract
The aim of this study was to evaluate the structural conformations of three clear aligner systems, Eon®, SureSmile®, and Clarity®, and compare them with the most commonly used system, Invisalign®. Clear aligner samples from Invisalign®, Eon®, SureSmile®, and Clarity® were cut into 5 × 5 mm squares and exposed to artificial saliva for 2 weeks. The specimens were then subjected to a Vickers hardness test by applying three separate indentations with a 25 gf load for 15 s. Hardness was calculated using the following formula: Vickers hardness number = 1.854 (F/D2). Fourier transform infrared spectroscopy (FTIR) analysis was performed, with a diamond hemisphere and infrared beam being allowed to pass through each specimen. A mid-infrared range from 4000 to 375 cm−1 was recorded. The samples were also evaluated using scanning electron microscopy (SEM) combined with energy-dispersive X-ray microanalysis spectroscopy at different magnifications. No statistically significant differences were observed between the included systems with regard to hardness. All systems showed a polyurethane-based material, as illustrated by the FTIR analysis. Some structural variations were noted in the Invisalign® system, which had a more homogeneous architecture. Statistically significant differences in the carbon weights were found among the systems. The four systems presented comparable hardness levels. Mild molecular composition differences were found, but all systems had the similarity of being composed of a polyurethane-based material. Carbon and oxygen were the main elements, as they were located in all studied clear aligners. The SEM analysis revealed that Invisalign® had a smoother surface than the other three systems. All included clear aligners had similar characteristics with minimal differences, providing a wide variety of options for clinical orthodontic treatment according to patients’ demands.
Collapse
Affiliation(s)
- Aseel Alhendi
- Department of Pediatric Dentistry and Orthodontics, College of Dentistry, King Saud University, Riyadh 11545, Saudi Arabia;
- Correspondence: ; Tel.: +966-541-419-097
| | - Rita Khounganian
- Department of Oral Medicine and Diagnostic Sciences, College of Dentistry, King Saud University, Riyadh 11545, Saudi Arabia;
| | - Raisuddin Ali
- Department of Pharmaceutics, College of Pharmacy, King Saud University, Riyadh 11451, Saudi Arabia;
| | - Saeed Ali Syed
- Department of Pharmaceutical Chemistry, College of Pharmacy, King Saud University, Riyadh 11451, Saudi Arabia;
| | - Abdullazez Almudhi
- Department of Pediatric Dentistry and Orthodontics, College of Dentistry, King Saud University, Riyadh 11545, Saudi Arabia;
| |
Collapse
|
21
|
Jia L, Wang C, Wang C, Song J, Fan Y. Efficacy of various multi-layers of orthodontic clear aligners: a simulated study. Comput Methods Biomech Biomed Engin 2022; 25:1710-1721. [PMID: 35188858 DOI: 10.1080/10255842.2022.2034796] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
BACKGROUND In the invisible orthodontic treatment, composite thermoforming film materials have become the focus of orthodontic clear aligners. The orthodontic efficacy of clear aligners which consisted of multi-layers materials remains unclear. This study aims to evaluate the biomechanical effects of various multi-layers of clear aligners on en-mass retraction of maxillary anterior teeth. METHODS A patient-specific 3D non-linear finite element model numerical analysis was constructed to simulate the en-mass retraction of maxillary anterior teeth with clear aligner after extraction of the first premolars. Four kinds of multi-layers clear aligners with different proportion of film materials were simulated. The biomechanical responses of four different clear aligners on invisible orthodontics were calculated. The tooth displacement in all directions, the hydrostatic pressure of periodontal ligament, the orthodontic deformation of clear aligner, and the stress distribution of alveolar bone were compared and investigated. RESULTS In all experimental models, the maximum equivalent deformation of alveolar bone, the vector displacement of tooth and the compressive/tensile stress of periodontal ligament decreased with the increase of soft layer thickness. The elastic strain of clear aligners also decreased with the increase of the ratio of soft/hard layers. CONCLUSIONS The multi-layers clear aligner is better than the single-layer clear aligner in tooth movement, stress distribution of periodontal ligament and mechanical loading of alveolar bone, especially when the ratio of soft layer to hard layer is more than 50%. Moreover, the side effects of the multi-layers clear aligner are significantly less than those of the single-layer one.
Collapse
Affiliation(s)
- Lurong Jia
- Chongqing Key Laboratory of Oral Diseases and Biomedical Sciences, Chongqing, China.,Stomatological Hospital of Chongqing Medical University, Chongqing, China
| | - Chunjuan Wang
- Chongqing Key Laboratory of Oral Diseases and Biomedical Sciences, Chongqing, China.,Stomatological Hospital of Chongqing Medical University, Chongqing, China
| | - Chao Wang
- Stomatological Hospital of Chongqing Medical University, Chongqing, China.,Beijing Advanced Innovation Center for Biomedical Engineering, Beihang University, Beijing, China.,Key Laboratory for Biomechanics and Mechanobiology (Beihang University), Ministry of Education, 100191 Beijing, China
| | - Jinlin Song
- Chongqing Key Laboratory of Oral Diseases and Biomedical Sciences, Chongqing, China.,Stomatological Hospital of Chongqing Medical University, Chongqing, China.,Chongqing Municipal Key Laboratory of Oral Biomedical Engineering of Higher Education, Chongqing, China
| | - Yubo Fan
- Beijing Advanced Innovation Center for Biomedical Engineering, Beihang University, Beijing, China.,Key Laboratory for Biomechanics and Mechanobiology (Beihang University), Ministry of Education, 100191 Beijing, China
| |
Collapse
|
22
|
Charavet C, Gourdain Z, Graveline L, Lupi L. Cleaning and Disinfection Protocols for Clear Orthodontic Aligners: A Systematic Review. Healthcare (Basel) 2022; 10:healthcare10020340. [PMID: 35206954 PMCID: PMC8871989 DOI: 10.3390/healthcare10020340] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2022] [Revised: 02/03/2022] [Accepted: 02/07/2022] [Indexed: 01/25/2023] Open
Abstract
(1) Background: Clear orthodontic aligners support the development of oral biofilms, which could lead to interferences with the oral microbiota already existing and the deterioration of oral health, with the development of dental caries, periodontal disease and even systemic infections. Therefore, preventive oral health care requires a cleaning and disinfection procedure for aligners. (2) Methods: A systematic review of the literature was conducted across four databases following the PRISMA guidelines up to May 2021, combining an electronic and a manual search. Prospective studies, including randomized controlled trials (RCTs), crossover studies (COSs) and controlled clinical trials (CCTs), published in the English language without time restrictions, evaluating the efficacy of cleaning and disinfection protocols for clear orthodontic aligners by comparing them with a placebo or a negative control, were included. The article selection, data extraction and risk of bias assessment were performed by two independent blinded review authors. In case of disagreement, a third author was solicited throughout the selection process. (3) Results: Among the 221 articles screened in the search process, 4 studies were included in the review, all designed as crossover studies (single arm without randomization with the same sequence of different cleaning and disinfection protocols for each participant). Different cleaning and disinfection methods were studied such as mechanical methods (brushing with toothpaste or vibration), chemical methods/pharmaceutical products (chlorhexidine antibacterial substance, anionic or cationic detergents or effervescent tablets) or combinations of both. (4) Conclusion: Although the determination of the most remarkable method of cleaning and disinfection was impossible because no direct comparison was conducted between all these methods, a multi-step protocol, including the combination of a mechanical and a chemical method, seems to be the most effective approach. Further research is needed to define the most preventive oral health care protocol. Registration: PROSPERO CRD 42021278498.
Collapse
Affiliation(s)
- Carole Charavet
- Université Côte d’Azur, Faculté de Chirurgie Dentaire, Département d’Orthodontie, 06800 Nice, France
- Centre Hospitalier Universitaire de Nice, Pôle Odontologie, 06000 Nice, France; (Z.G.); (L.G.)
- Laboratoire MICORALIS UPR 7354, Université Côte d’Azur, 06800 Nice, France
- Correspondence: or
| | - Zoé Gourdain
- Centre Hospitalier Universitaire de Nice, Pôle Odontologie, 06000 Nice, France; (Z.G.); (L.G.)
- Université Côte d’Azur, Faculté de Chirurgie Dentaire, 06800 Nice, France
| | - Léa Graveline
- Centre Hospitalier Universitaire de Nice, Pôle Odontologie, 06000 Nice, France; (Z.G.); (L.G.)
- Université Côte d’Azur, Faculté de Chirurgie Dentaire, 06800 Nice, France
| | - Laurence Lupi
- Centre Hospitalier Universitaire de Nice, Pôle Odontologie, 06000 Nice, France; (Z.G.); (L.G.)
- Laboratoire MICORALIS UPR 7354, Université Côte d’Azur, 06800 Nice, France
- Université Côte d’Azur, Faculté de Chirurgie Dentaire, Département de Santé Publique, 06800 Nice, France;
| |
Collapse
|
23
|
Cytotoxicity evaluation of different clear aligner materials using MTT analysis. AUSTRALASIAN ORTHODONTIC JOURNAL 2022. [DOI: 10.2478/aoj-2022-0034] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Abstract
Backround: The in vitro cytotoxic effects of six different clear aligner materials were evaluated using the MTT analysis.
Methods: The clear aligner material samples [Duran (ScheuDental GmbH, Iserlohn, Germany), Zendura-Flx (Bay Materials LLC, Fremont, CA, USA), Taglus (Laxmi Dental Export Pvt. Ltd, Mumbai, India), Smart Track (Align Technology, San Jose, CA, USA), Zendura (Bay Materials LLC, Fremont, CA, USA), Essix C + (Essix® (Raintree Essix, Inc., 4001 Division St, Metairie, LA-USA)] were initially kept in a saline solution in airtight test tubes for 8 weeks at 37°C. According to the recommended ISO standards, the weights of the samples were divided by the volumes of the dilutions in the ratio of 0.1 g/ml. To evaluate the cytotoxicity of the samples, an MTT analysis was performed using a human gingival fibroblast cell line (HGF). To analyse the data, the Kruskal– Wallis test was applied (a=0.05).
Results: Zendura was the most cytotoxic material resulting in 67.3 ± 16.20% cell viability, followed by Smart Track with 87.6 ± 5.53% cell viability. While Duran, Essix C + had 92.6 ± 26.34% and 94.9 ± 8.54% cell viability, Zendura-Flx, Taglus had 106.9 ± 12.76% and 113.183 ± 7.45% cell viability, respectively.
Conclusion: While Zendura and Smart Track showed mild cytotoxicity, other materials showed greater cell viabilities. According to the ISO standards, the clinical use of each brand of aligners, except Zendura, may be considered reliable. Taking into account standard deviation, Zendura and Duran should be used with caution. The suppliers of aligners should adhere to the manufacturer’s recommendations since an increase in ion release might arise from material wear.
Collapse
|
24
|
ERGEL D, SADRY S, OK U. Ortodontide Kullanılan Şeffaf Plakların Su Emilimlerinin ve Renklenmelerinin Değerlendirmesi. İSTANBUL GELIŞIM ÜNIVERSITESI SAĞLIK BILIMLERI DERGISI 2021. [DOI: 10.38079/igusabder.1010796] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
|
25
|
Color Stability, Chemico-Physical and Optical Features of the Most Common PETG and PU Based Orthodontic Aligners for Clear Aligner Therapy. Polymers (Basel) 2021; 14:polym14010014. [PMID: 35012036 PMCID: PMC8747426 DOI: 10.3390/polym14010014] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2021] [Revised: 12/16/2021] [Accepted: 12/17/2021] [Indexed: 02/03/2023] Open
Abstract
It is difficult to find research papers collecting comparative results about characterization studies of clear aligners. Therefore, the aim of this paper is to provide the first comparative analysis of most commercial clear aligners, in terms of their stability towards intra-oral staining agents, their physicochemical and optical properties, as well as their water absorption behavior. Five types of aligners, characterized by different techniques, are considered: Erkodur, Essix Plastic, Ghost Aligner, Zendura, and Invisalign. The obtained results show that clear aligners are made up of PETG, semi rigid PU, and a mixture of PU and PETG, with different degrees of crystallinity which affect the transparency of each aligner. In particular, the PETG-based materials reveal the highest value of short-range order and the highest properties in terms of transparency in the visible range. After 14 days of immersion into red wine and coffee, PETG and PU-based aligners reveal a perceivable change in color (NBS values from 1.5 to 3), corresponding to a loss of transparency due to the deposition of impurities on the surface. These results are particularly marked for Invisalign, showing changes towards other colors (NBS up to 35), probably due to the thermoforming process which led to the formation of a wrinkled surface entrapping the impurities.
Collapse
|
26
|
Zinelis S, Panayi N, Polychronis G, Papageorgiou SN, Eliades T. Comparative analysis of mechanical properties of orthodontic aligners produced by different contemporary 3D printers. Orthod Craniofac Res 2021; 25:336-341. [PMID: 34569692 PMCID: PMC9544566 DOI: 10.1111/ocr.12537] [Citation(s) in RCA: 26] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2021] [Revised: 09/22/2021] [Accepted: 09/23/2021] [Indexed: 12/11/2022]
Abstract
OBJECTIVE The aim of this study was to compare the mechanical properties of orthodontic aligners among different commercially available 3D printing devices. MATERIALS AND METHODS Five 3D printers (Ka:rv LP 550, Swinwon; "KAR"), (L120, Dazz 3D; "L12"), (MiiCraft 125, Miicraft Jena; "MIC"), (Slash 2, Uniz; "SLS") and (Pro 95, SprintRay; "PRO") were used to prepare orthodontic aligners with dental resin (Tera Harz TC-85DAW, Graphy). The central incisors of each aligner were cut, prepared and evaluated in terms of Martens-Hardness (HM), indentation-modulus (EIT ) and elastic-index (ηIT ) as per ISO14577-1:2002. Force-indentation curves were recorded and differences among printers were checked with generalized linear regressions (alpha=5%). RESULTS Statistically significant differences were seen for all mechanical properties (P < .05), which were in descending order: HM (N/mm2 ) as median (Interquartile Range [IQR]): SLS 108.5 (106.0-112.0), L12 103.0 (102.0-107.0), KAR 101.5 (97.5-103.0), MIC 100.0 (97.5-101.5) and PRO 94.0 (93.0-96.0); EIT (MPa) as mean (Standard Deviation [SD]): SLS 2696.3 (124.7), L12 2627.8 (73.5), MIC 2566.2 (125.1), KAR 2565.0 (130.2) and PRO 2491.2 (53.3); and ηIT (%) as median (IQR): SLS 32.8 (32.3-33.1), L12 31.6 (30.8-32.3), KAR 31.3 (30.9-31.9), MIC 30.5 (29.9-31.2) and PRO 29.5 (29.1-30.0). Additionally, significant differences existed between liquid crystal display (LCD) and digital light processing (DLP) printers for HM (P < .001), EIT (P = .002) and ηIT (P < .001), with aligners from the former having higher values than aligners from the latter printer. CONCLUSION Under the limitations of this study, it may be concluded that the mechanical properties of 3D-printed orthodontic aligners are dependent on the 3D printer used, and thus, differences in their clinical efficacy are anticipated.
Collapse
Affiliation(s)
- Spiros Zinelis
- Department of Biomaterials, School of Dentistry, National and Kapodistrian University of Athens, Athens, Greece
| | | | - Georgios Polychronis
- Department of Biomaterials, School of Dentistry, National and Kapodistrian University of Athens, Athens, Greece
| | - Spyridon N Papageorgiou
- Clinic of Orthodontics and Pediatric Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland
| | - Theodore Eliades
- Clinic of Orthodontics and Pediatric Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland
| |
Collapse
|
27
|
Dalaie K, Fatemi SM, Ghaffari S. Dynamic mechanical and thermal properties of clear aligners after thermoforming and aging. Prog Orthod 2021; 22:15. [PMID: 34180030 PMCID: PMC8236420 DOI: 10.1186/s40510-021-00362-8] [Citation(s) in RCA: 24] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2021] [Accepted: 05/12/2021] [Indexed: 11/10/2022] Open
Abstract
Background Based on the role of properties of aligner materials on their efficiency, we aimed to assess their thermomechanical properties after thermoforming and simulated aging. Methods In this experimental study, 96 samples of polyethylene terephthalate glycol (PETG) aligners (Duran and Erkodur) were prepared and divided to three groups: control (C), after thermoforming (T), after thermoforming and aging (TA). Thermoforming was done through 3D-printed molds, and aging was exerted by 200 thermal cycles after immersion in 37°C distilled water for 24h. Flexural modulus, hardness, glass transition temperature (Tg), elastic and viscous modulus, and loss factor were evaluated. Two-way ANOVA, T-independent, and Tukey HSD tests were done for statistical analysis and significance level was set to 0.05. Results In both materials, flexural modulus decreased significantly after thermoforming, 88% in Duran and 70% in Erkodur, but did not change significantly after aging. After thermoforming, hardness decreased significantly in both materials (22% in Duran and 7.6% in Erkodur). Dynamic Tg was significantly lower in T and TA in both materials. At all temperatures (25, 37, 55°C) in Duran, the elastic modulus difference was only significant between C and TA, but in Erkodur, it decreased significantly in T, and there was no significant change after aging. Viscous modulus and loss factor showed the same change patterns at all temperatures. In both materials, they increased after thermoforming, but did not change significantly after aging. Conclusion Thermoforming had more prominent role than aging in diminishing of thermomechanical properties. In general, Duran had greater thermomechanical stability than Erkodur.
Collapse
Affiliation(s)
- Kazem Dalaie
- Department of Orthodontics, School of Dentistry, Shahid Beheshti University of Medical Sciences, Daneshju Boulevard, Velenjak District, Tehran, Iran
| | - Seyyed Mostafa Fatemi
- Department of Dental Biomaterials, School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Samin Ghaffari
- Department of Orthodontics, School of Dentistry, Shahid Beheshti University of Medical Sciences, Daneshju Boulevard, Velenjak District, Tehran, Iran. .,Dentofacial Deformities Research Center, Research Institute of Dental Sciences, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
| |
Collapse
|
28
|
Condò R, Mampieri G, Giancotti A, Cerroni L, Pasquantonio G, Divizia A, Convertino A, Mecheri B, Maiolo L. SEM characterization and ageing analysis on two generation of invisible aligners. BMC Oral Health 2021; 21:316. [PMID: 34162371 PMCID: PMC8223277 DOI: 10.1186/s12903-021-01676-z] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2020] [Accepted: 06/11/2021] [Indexed: 11/25/2022] Open
Abstract
Background The purpose of the in vitro study is to investigate and compare the morphological features and the chemical stability in weight of two different polyurethane-based blends, Smart Track (LD30) and Exceed30 (EX30), used for orthodontic aligners manufacture before and after the oral usage. Methods Twenty orthodontic aligners were randomly selected: 10 LD30 and 10 EX30, each group was divided in two subgroups, never used and intra-orally aged. By the employment of a Stereomicroscope, a section of 5 × 5 mm was cut from the buccal surface of the incisal region of each aligner. All samples were subjected to Scanning Electron Microscopy and Ageing tests in different solutions to simulate the hostility of the oral environment. The statistical method used was t-test. Results At SEM images, LD30 appears more homogeneous in texture respect to EX30. However, after clinical usage, both materials show significant structural alterations: findings have been supported by higher magnifications at SEM, by which it is clearly to observe many superficial cracks cross through the polymer structures of LD30U, absent in never used samples. LD30U surface becomes also smoother due to the disappearance of most of the conglomerates, but at the same time also rougher while EX30U shows a greater irregularity and porosity in which large and deep cracks are also highlighted. Although these changes occur persistently, in the aging tests no significant weight loss from both materials has been found, confirming the initial hypothesis of a good chemical stability and safety of both polyurethane mixtures even in conditions of severe hostility. Conclusion LD30 is the expression of the technological evolution of EX30, this is made evident above all by its morphological architecture, more homogeneous and defined but also by the chemical stability that can be appreciated even in evident critic situations.
Collapse
Affiliation(s)
- Roberta Condò
- Department of Clinical Sciences and Translational Medicine, University of Rome "Tor Vergata", Viale Oxford 81, 00133, Rome, Italy.
| | - Gianluca Mampieri
- Department of Clinical Sciences and Translational Medicine, University of Rome "Tor Vergata", Viale Oxford 81, 00133, Rome, Italy
| | - Aldo Giancotti
- Department of Clinical Sciences and Translational Medicine, University of Rome "Tor Vergata", Viale Oxford 81, 00133, Rome, Italy
| | - Loredana Cerroni
- Department of Clinical Sciences and Translational Medicine, University of Rome "Tor Vergata", Viale Oxford 81, 00133, Rome, Italy
| | - Guido Pasquantonio
- Department of Clinical Sciences and Translational Medicine, University of Rome "Tor Vergata", Viale Oxford 81, 00133, Rome, Italy
| | - Andrea Divizia
- PhD in Nursing Sciences and Public Health, University of Rome "Tor Vergata", Via Montpellier, 1, 00133, Rome, Italy
| | - Annalisa Convertino
- Institute for Microelectronics and Microsystems - National Research Council, Unit of Rome, Via del Fosso del Cavaliere, 100, 00133, Rome, Italy
| | - Barbara Mecheri
- Department of Chemical Science and Technologies, University of Rome "Tor Vergata", Via della Ricerca Scientifica, 1, 000133, Rome, Italy
| | - Luca Maiolo
- Institute for Microelectronics and Microsystems - National Research Council, Unit of Rome, Via del Fosso del Cavaliere, 100, 00133, Rome, Italy
| |
Collapse
|
29
|
The force effects of two types of polyethylene terephthalate glyc-olmodified clear aligners immersed in artificial saliva. Sci Rep 2021; 11:10052. [PMID: 33980889 PMCID: PMC8115163 DOI: 10.1038/s41598-021-89425-8] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2020] [Accepted: 04/20/2021] [Indexed: 11/08/2022] Open
Abstract
Numerous factors can influence the force exerted by clear aligners on teeth. This study aimed to investigate the stability of the force delivered by two different material appliances. 90 clear aligners with 2 materials and three different activations were designed and fabricated. Then, a device was employed to measure the force generated by the two types of PET-G material appliances immersed in artificial saliva for 0, 3, 7, 10, 14 days. Scanning electron microscopy was applied to observe the morphologic alterations on the aligner surfaces, respectively. The forces generated by different activation appliance exhibited differently, 0.0 mm < 0.1 mm < 0.2 mm. In addition, increasing the immersion times and the orthodontic force also decreased, but the forces decreased differently. Compared with the forces of conventional PETG appliances with 0.20 mm activation, the modified PETG appliances with the same activation exhibited significantly higher mean force. When comparing the mean force for modified PETG appliances after 10 and 14 days with conventional PETG appliances, the delivery forces exhibited significant differences (P < 0.05). The force delivered by both materials decreased obviously following artificial saliva immersion, and the force generated by modified aligners exhibited better stability than conventional aligners.
Collapse
|
30
|
Putrino A, Barbato E, Galluccio G. Clear Aligners: Between Evolution and Efficiency-A Scoping Review. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2021; 18:ijerph18062870. [PMID: 33799682 PMCID: PMC7998651 DOI: 10.3390/ijerph18062870] [Citation(s) in RCA: 34] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/11/2021] [Revised: 02/18/2021] [Accepted: 03/02/2021] [Indexed: 12/21/2022]
Abstract
In recent years, clear aligners have diversified and evolved in their primary characteristics (material, gingival margin design, attachments, divots, auxiliaries), increasing their indications and efficiency. We overviewed the brands of aligners used in Italy and reviewed the literature on the evolution of clear aligners based on their characteristics mentioned above by consulting the main scientific databases (PubMed, Scopus, Lilacs, Google Scholar, Cochrane Library). Inclusion and exclusion criteria were established. The data were collected on a purpose-made data collection form and analyzed descriptively. From the initial 580 records, 527 were excluded because they were not related to the subject of the review or because they did not meet the eligibility criteria. The remaining 31 studies were deemed comprehensive for the purpose of the review, although the “gingival margin design” feature and “auxiliaries” tool are not well represented in the more recent literature. Current knowledge on invisible aligners allows us to have a much clearer idea of the basic characteristics of aligner systems. There remains a need to deepen the use of systems other than Invisalign™ to give greater evidence to aligners that are very different based on the characteristics analyzed here and that are very widespread on the market.
Collapse
|
31
|
ATR-FTIR Analysis of Orthodontic Invisalign ® Aligners Subjected to Various In Vitro Aging Treatments. MATERIALS 2021; 14:ma14040818. [PMID: 33572096 PMCID: PMC7914755 DOI: 10.3390/ma14040818] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/24/2020] [Revised: 02/03/2021] [Accepted: 02/04/2021] [Indexed: 11/16/2022]
Abstract
Clear and removable tooth aligners for orthodontics treatments have become an increasingly popular alternative to fixed appliances. Even if protocols suggest removing aligners before eating or drinking, most patients retain them when they drink beverages. Alterations in the material during the daily use could determine a reduction in the application forces, affecting the desired orthodontic movement; the knowledge of how this material reacts when subjected to different aging processes is mandatory to establish the predictability of the orthodontic treatment. According to this, the aim of the present study was to assess a new objective approach, coupling spectroscopic and chemometric tools, to evaluate the changes occurring in Invisalign® aligners, the most widely used brand, exposed in vitro to coffee, tea, Coca Cola® and UV radiation for 24 and 48 h. In particular, ATR-FTIR spectroscopy was utilized to characterize, at the molecular level, the chemical and color modifications in the surfaces of the appliances; the obtained data were submitted to PCA and one-way ANOVA and Tukey's multiple comparison test. Moreover, a colorimetry analysis was carried out to evaluate any changes in color and transparency. Coffee and tea samples displayed the major color changes between the tested groups. The differences highlighted in the spectral features of coffee, tea and UV-treated samples were mainly ascribable to color and transparency changes, because the chemical properties remained unaltered.
Collapse
|
32
|
Yaosen C, Mohamed AM, Jinbo W, Ziwei Z, Al-balaa M, Yan Y. Risk Factors of Composite Attachment Loss in Orthodontic Patients during Orthodontic Clear Aligner Therapy: A Prospective Study. BIOMED RESEARCH INTERNATIONAL 2021; 2021:6620377. [PMID: 33553424 PMCID: PMC7847320 DOI: 10.1155/2021/6620377] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 10/11/2020] [Revised: 01/16/2021] [Accepted: 01/20/2021] [Indexed: 12/15/2022]
Abstract
BACKGROUND The composite attachment loss during orthodontic clear aligner therapy is an adverse event that commonly happens in our daily practice. However, there is a lack of related statistical analysis and studies analyzing the related risk factors. Therefore, the aim of this study is to assess the incidence of attachment loss during orthodontic clear aligner therapy and to identify rick factors that may predict such event. MATERIALS AND METHODS The demographics and clinical variables of 94 patients undergoing clear aligner therapy (27 males and 67 females; average age: 27.60 ± 0.86 years) were recorded. Both patient-related and tooth-related attachment loss was recorded. The chi-squared test and logistic regressive analysis were applied to identify the potential risk factors. SPSS for Mac (version 23.0, IBM, USA) was used for statistical analyses. P < 0.05 was considered statistically significant. RESULTS Our study suggested that the risk factors for attachment loss include frequent aligner removal (≥ 5 times a day) (losing rate = 60.0%, P = 0.005), aligner wear time less than 18 hours a day (losing rate = 50.8%, P = 0.014), eating without aligners inserted (losing rate = 47.9%, P = 0.034), utilizing aligner tray seaters (losing rate = 48.2%, P = 0.006), and unilateral mastication (losing rate = 52.1%, P = 0.002). The multivariable logistic regression analysis indicates that aligner wear time less than 18 hours a day (P = 0.020, B = 0.925), using aligner tray seaters (P = 0.007, B = 1.168), and unilateral mastication (P = 0.034, B = -0.458) were considered independent factors that can predict the composite attachment loss in orthodontic clear aligner therapy. CONCLUSION Wearing aligner less than 18 hours a day, using aligner tray seaters, and unilateral mastication may contribute to increased incidence of composite attachment loss during orthodontic clear aligner therapy.
Collapse
Affiliation(s)
- Chen Yaosen
- MDS Orthodontic Section of Stomatology Department, Zhongnan Hospital, Wuhan University, Wuhan, China 430000
| | - A. M. Mohamed
- MDS Orthodontic Section of Stomatology Department, Zhongnan Hospital, Wuhan University, Wuhan, China 430000
| | - Wang Jinbo
- Master of Nursing Department, Zhongnan Hospital, Wuhan University, Wuhan, China 430000
| | - Zheng Ziwei
- College of Stomatology, Hubei University of Science and Technology, Xianning, China 437000
| | - Maher Al-balaa
- MDS Orthodontic Section of School of Stomatology, Wuhan University, Wuhan, China 430000
| | - Yang Yan
- Stomatology Department, Zhongnan Hospital, Wuhan University, Wuhan, Hubei 430000, China
| |
Collapse
|
33
|
Behaviour of Human Oral Epithelial Cells Grown on Invisalign ® SmartTrack ® Material. MATERIALS 2020; 13:ma13235311. [PMID: 33255259 PMCID: PMC7727678 DOI: 10.3390/ma13235311] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/14/2020] [Revised: 11/13/2020] [Accepted: 11/15/2020] [Indexed: 11/18/2022]
Abstract
Invisalign aligners have been widely used to correct malocclusions, but their effect on oral cells is poorly known. Previous research evaluated the impact of aligners’ eluates on various cells, but the cell behavior in direct contact with aligners is not yet studied. In the present study, we seeded oral epithelial cells (cell line Ca9-22) directly on Invisalign SmartTrack material. This material is composed of polyurethane and co-polyester and exhibit better mechanical characteristics compared to the predecessor. Cell morphology and behavior were investigated by scanning electron microscopy and an optical cell moves analyzer. The effect of aligners on cell proliferation/viability was assessed by cell-counting kit (CCK)-8 and 3,4,5-dimethylthiazol-2-yl-2,5-diphenyl tetrazolium bromide (MTT) assay and live/dead staining. The expression of inflammatory markers and proteins involved in epithelial barrier function was measured by qPCR. Cells formed cluster-like structures on aligners. The proliferation/viability of cells growing on aligners was significantly lower (p < 0.05) compared to those growing on tissue culture plastic (TCP). Live/dead staining revealed a rare occurrence of dead cells on aligners. The gene expression level of all inflammatory markers in cells grown on aligners’ surfaces was significantly increased (p < 0.05) compared to cells grown on TCP after two days. Gene expression levels of the proteins involved in barrier function significantly increased (p < 0.05) on aligners’ surfaces after two and seven days of culture. Aligners’ material exhibits no cytotoxic effect on oral epithelial cells, but alters their behavior and the expression of proteins involved in the inflammatory response, and barrier function. The clinical relevance of these effects has still to be established.
Collapse
|
34
|
Hannequin R, Ouadi E, Racy E, Moreau N. Clinical follow-up of corticotomy-accelerated Invisalign orthodontic treatment with Dental Monitoring. Am J Orthod Dentofacial Orthop 2020; 158:878-888. [PMID: 33129633 DOI: 10.1016/j.ajodo.2019.06.025] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/01/2019] [Revised: 05/01/2019] [Accepted: 06/01/2019] [Indexed: 11/17/2022]
Abstract
The demand for fast and invisible treatment options for adults has grown. Treatment protocols involving clear aligners in association with alveolar corticotomy have been developed in response to this demand. Alveolar corticotomy surgery can accelerate orthodontic tooth movement, but good clinical follow-up is crucial and can become cumbersome as the frequency of aligner changes accelerates. Clinical monitoring with patient-managed software can be of assistance in such cases. We present the ortho-surgical treatment of a healthy 21-year-old woman with Class III malocclusion who was treated with corticotomy-accelerated presurgical decompensation and clear aligners, followed by mandibular sagittal split osteotomy. Alveolar corticotomy surgery was performed and the aligners were changed every 4 days. Clinical follow-up of aligner-mediated tooth movement was managed with a patient-managed smartphone application, allowing early interception and correction of minute orthodontic movement errors. Such errors would have been difficult to detect considering the rapidity of aligner change when accelerated by alveolar corticotomy. Clinical follow-up with a patient-managed smartphone application could thus allow for better and easier management of corticotomy-accelerated clear aligner orthodontic treatment.
Collapse
Affiliation(s)
- Ronan Hannequin
- Department of Orthodontics and Dentofacial Orthopedics, Bretonneau Hospital, Paris, France
| | - Elea Ouadi
- Department of Orthodontics and Dentofacial Orthopedics, Bretonneau Hospital, Paris, France; Faculty of Dental Surgery, Paris Descartes University, Montrouge, France
| | | | - Nathan Moreau
- Faculty of Dental Surgery, Paris Descartes University, Montrouge, France; Department of Oral Medicine and Oral Surgery, Bretonneau Hospital, Paris, France.
| |
Collapse
|
35
|
Porojan L, Vasiliu RD, Porojan SD, Bîrdeanu MI. Surface Quality Evaluation of Removable Thermoplastic Dental Appliances Related to Staining Beverages and Cleaning Agents. Polymers (Basel) 2020; 12:polym12081736. [PMID: 32756439 PMCID: PMC7464035 DOI: 10.3390/polym12081736] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2020] [Revised: 07/30/2020] [Accepted: 08/01/2020] [Indexed: 01/04/2023] Open
Abstract
(1) Background: Thermoplastic materials are not inert and subject to changes in the oral environment, which affect their surface quality. Color stability and topographic characteristics of clear thermoplastic appliances are critical considerations. The study aimed to evaluate the optical changes and surface topography of different thermoplastic materials related to staining beverages and cleaning agents. (2) Methods: Thermoplastic polyethylene terephthalate glycol (PET-G) material specimens were selected for the study: S (Duran, Scheu-Dental GmbH, Iserlohn, Germany), D (Biolon, Dreve Dentamid GmbH, Unna, Germany), and B (Crystal, Bio Art Dental Equipment, Sao Carlos, Brazil). Four different media were involved for immersion: coffee (C) and black tea (T) at 55 °C, Coca-Cola (K) at 5 °C, and distilled water (W) at 22 °C. As for cleaning, chemical options and mechanical brushing were selected (P-powder, T-tablets, and X-brushing). Color changes, and mean surface roughness were measured at 24 h, 48 h, and after 7 days. Statistical analysis was performed. After the testing period, atomic force microscopy (AFM) analyses and SEM images were registered in order to characterize the surface topography. (3) Results: Quantitative color change evaluations revealed a slight change in color after 24 h and an extremely marked change after 48 h, respective 7 days. Mean roughness values are kept below the clinically acceptable limit of 0.20 µm for all samples. Related to mean nanoroughness values Sa, and 3D evaluations of the surface quality, Biolon samples have demonstrated the most constant behavior, while Crystal samples are visibly influenced by water immersion. Related to the cleaning method, the topography of Duran samples was influenced by mechanical brushing. (4) Conclusions: Nanoscale investigations provided high accuracy and more realistic surface quality examinations of the examined samples compared to profilometry. Both SEM and AFM should be used for a more detailed description of the surface topography.
Collapse
Affiliation(s)
- Liliana Porojan
- Department of Dental Prostheses Technology (Dental Technology), “Victor Babeș” University of Medicine and Pharmacy Timișoara, Romania, Eftimie Murgu Sq. no. 2, 300041 Timișoara, Romania;
| | - Roxana-Diana Vasiliu
- Department of Dental Prostheses Technology (Dental Technology), “Victor Babeș” University of Medicine and Pharmacy Timișoara, Romania, Eftimie Murgu Sq. no. 2, 300041 Timișoara, Romania;
- Correspondence: ; Tel.: +40-745225523
| | - Sorin-Daniel Porojan
- Department of Oral Rehabilitation (Dental Technology), “Victor Babeș” University of Medicine and Pharmacy Timișoara, Romania, Eftimie Murgu Sq. no. 2, 300041 Timișoara, Romania;
| | - Mihaela-Ionela Bîrdeanu
- National Institute for Research and Development in Electrochemistry and Condensed Matter, 300569 Timisoara, Romania;
| |
Collapse
|
36
|
Daniele V, Macera L, Taglieri G, Di Giambattista A, Spagnoli G, Massaria A, Messori M, Quagliarini E, Chiappini G, Campanella V, Mummolo S, Marchetti E, Marzo G, Quinzi V. Thermoplastic Disks Used for Commercial Orthodontic Aligners: Complete Physicochemical and Mechanical Characterization. MATERIALS 2020; 13:ma13102386. [PMID: 32455913 PMCID: PMC7287673 DOI: 10.3390/ma13102386] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/12/2020] [Revised: 05/14/2020] [Accepted: 05/18/2020] [Indexed: 12/13/2022]
Abstract
Invisible orthodontic aligners (IOAs) have been introduced in the orthodontic field as an innovative alternative for fixed brackets, in relation to their ability to be easily inserted/removed from the oral cavity without affecting the chewing ability and the aesthetic of the patients. The paper provides a complete physicochemical and mechanical characterization of thermoplastic materials in the form of disks used for commercial IOAs. A wide palette of specific techniques is considered, from tensile tests and dynamic-mechanical analysis, to X-Ray diffraction (XRD), differential scanning calorimetry (DSC), Fourier transformation infrared spectroscopy (FTIR-ATR) analyses and water absorption tests. The disks are investigated before and after immersion into staining beverages (red wine, coffee, nicotine and artificial saliva), in terms of colour variations, transparency, and microscopic surface modifications by means of colorimetry, UV-VIS absorbance and scanning electron microscopy (SEM). Among all the samples, polyurethane (PU) exhibited the highest crystallinity and the highest values of mechanical and thermal resistance, while the poly(ethylene terephthalate)-glycol (PETG) samples presented better transparency and less ability to absorb water. Moreover, red wine and coffee give noticeable colour variations after 14 days of immersion, together with a slight reduction of transparency.
Collapse
Affiliation(s)
- Valeria Daniele
- Department of Industrial and Information Engineering and Economics, University of L’Aquila, Piazzale Pontieri 1, Monteluco di Roio, 67100 L’Aquila, Italy; (V.D.); (G.T.); (A.D.G.); (G.S.)
| | - Ludovico Macera
- Department of Industrial and Information Engineering and Economics, University of L’Aquila, Piazzale Pontieri 1, Monteluco di Roio, 67100 L’Aquila, Italy; (V.D.); (G.T.); (A.D.G.); (G.S.)
- Correspondence:
| | - Giuliana Taglieri
- Department of Industrial and Information Engineering and Economics, University of L’Aquila, Piazzale Pontieri 1, Monteluco di Roio, 67100 L’Aquila, Italy; (V.D.); (G.T.); (A.D.G.); (G.S.)
| | - Alessandra Di Giambattista
- Department of Industrial and Information Engineering and Economics, University of L’Aquila, Piazzale Pontieri 1, Monteluco di Roio, 67100 L’Aquila, Italy; (V.D.); (G.T.); (A.D.G.); (G.S.)
| | - Giuseppe Spagnoli
- Department of Industrial and Information Engineering and Economics, University of L’Aquila, Piazzale Pontieri 1, Monteluco di Roio, 67100 L’Aquila, Italy; (V.D.); (G.T.); (A.D.G.); (G.S.)
| | - Alessandra Massaria
- Department of Life, Health & Environmental Sciences, Postgraduate School of Orthodontics, University of L’Aquila, P.le Salvatore Tommasi 1, Ed. Delta 6, 67100 L’Aquila, Italy; (A.M.); (S.M.); (E.M.); (G.M.); (V.Q.)
| | - Massimo Messori
- Department of Engineering ‘Enzo Ferrari’, University of Modena and Reggio Emilia, Via P. Vivarelli 10, 41125 Modena, Italy;
| | - Enrico Quagliarini
- Department of Construction, Civil Engineering and Architecture, Polytechnic University of Marche, 60121 Ancona, Italy;
| | - Gianluca Chiappini
- Department of Industrial Engineering and Mathematical Sciences, Polytechnic University of Marche, via Brecce Bianche snc, 60131 Ancona, Italy;
| | - Vincenzo Campanella
- Department of Clinical Science and Translational Medicine, University of Rome “Tor Vergata”, Via Montpellier 1, 00133 Roma, Italy;
| | - Stefano Mummolo
- Department of Life, Health & Environmental Sciences, Postgraduate School of Orthodontics, University of L’Aquila, P.le Salvatore Tommasi 1, Ed. Delta 6, 67100 L’Aquila, Italy; (A.M.); (S.M.); (E.M.); (G.M.); (V.Q.)
| | - Enrico Marchetti
- Department of Life, Health & Environmental Sciences, Postgraduate School of Orthodontics, University of L’Aquila, P.le Salvatore Tommasi 1, Ed. Delta 6, 67100 L’Aquila, Italy; (A.M.); (S.M.); (E.M.); (G.M.); (V.Q.)
| | - Giuseppe Marzo
- Department of Life, Health & Environmental Sciences, Postgraduate School of Orthodontics, University of L’Aquila, P.le Salvatore Tommasi 1, Ed. Delta 6, 67100 L’Aquila, Italy; (A.M.); (S.M.); (E.M.); (G.M.); (V.Q.)
| | - Vincenzo Quinzi
- Department of Life, Health & Environmental Sciences, Postgraduate School of Orthodontics, University of L’Aquila, P.le Salvatore Tommasi 1, Ed. Delta 6, 67100 L’Aquila, Italy; (A.M.); (S.M.); (E.M.); (G.M.); (V.Q.)
| |
Collapse
|
37
|
I. LPF, B.S. C, A.V A, Raju AS, P.C. RK, Shetty B. Effects of Carbonated Drinks on Mechanical Properties of Three Types of Thermoplastic Aligner Materials: An In vitro Study. JOURNAL OF INDIAN ORTHODONTIC SOCIETY 2020. [DOI: 10.1177/0301574219892421] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Objectives: The aim was to assess the mechanical properties of the three types of thermoplastic aligner materials before and after in vitro aging with carbonated drinks. Materials and methods: Twelve samples of thermoplastic aligner materials produced by three different manufacturers (Leone S.P.A, Florence, Italy; Duran, SCHEU-dental GmbH, Iserlohn, Germany; Essix ACE, Dentsply Raintree Essix, United States) were selected. Samples were thermoformed and later aged in vitro at a constant temperature in artificial saliva along with carbonated drinks (10 min each day) for 2 weeks. The mechanical properties were characterized using universal testing machine such as instron (MultiTest 10-i) and the results were compared with the control groups (before exposure to carbonated drinks). Results: All the above-mentioned thermoplastic materials tested showed an insignificant ( p > 0.05) decrease in stiffness, yield strength, and elastic modulus after aging. The stiffness of the thermoplastic materials increased with an increase in thickness. The flexure modulus was higher for the thinner materials, whereas it was lower for the thicker materials. Conclusion: Experimental results indicate that the aligner material will remain stable during and following exposure to carbonated drinks, which suggests that the orthodontic force from thermoplastic appliances does not decrease with clinical usage of carbonated drinks.
Collapse
Affiliation(s)
| | - Chandrashekar B.S.
- Krishnadevaraya College of Dental Sciences and Hospital, Bengaluru, Karnataka, India
| | - Arun A.V
- Krishnadevaraya College of Dental Sciences and Hospital, Bengaluru, Karnataka, India
| | - Aravind S. Raju
- Krishnadevaraya College of Dental Sciences and Hospital, Bengaluru, Karnataka, India
| | - Ramesh Kumar P.C.
- Krishnadevaraya College of Dental Sciences and Hospital, Bengaluru, Karnataka, India
| | - Balamohan Shetty
- Krishnadevaraya College of Dental Sciences and Hospital, Bengaluru, Karnataka, India
| |
Collapse
|
38
|
Bernard G, Rompré P, Tavares JR, Montpetit A. Colorimetric and spectrophotometric measurements of orthodontic thermoplastic aligners exposed to various staining sources and cleaning methods. Head Face Med 2020; 16:2. [PMID: 32070379 PMCID: PMC7027305 DOI: 10.1186/s13005-020-00218-2] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2019] [Accepted: 02/12/2020] [Indexed: 11/25/2022] Open
Abstract
Background Manufacturers of orthodontic aligners suggest that users remove appliances every time they consume solid foods or any drink (except water). This is to avoid a color change within the clear thermoplastic material of which they are made. However, limited quantitative evidence exists to guide users and practitioners in this regard. Herein, we evaluated the color stability of the polymer forming three different American brands of aligners and the stain-removal potential of two cleansers to provide such guidelines. Methods The removable appliances (300 specimens, 100 per brand) were exposed to different staining agents common in a regular diet (coffee, black tea, red wine, cola) or to a control solution in vitro over 12 h or 7 days. The three brands evaluated were Invisalign®, ClearCorrect® and Minor Tooth Movement®. These were then cleaned by using either Invisalign® cleaning crystals or the Cordless Sonic Cleaner combined with a Retainer Brite® tablet. The CIELAB color space approach was used to compare color changes (ΔE) in aligners before immersion (T0), after a 12-h exposure (T1), after a 7-day exposure (T2) and after cleaning (T3). Statistical methods (Levene’s test, ANOVA, Brunner-Langer model, Tukey’s range test and t-test) were used to identify interactions between the brands themselves or between the brands and the cleaning methods. Statistical analyses were performed at the .05 significance level. Results A 12-h or 7-day exposure to instant coffee or red wine significantly colored the Invisalign® aligners compared to the two other brands. Black tea created an important extrinsic color change for all three brands after 7 days. Clinically, both cleaning methods showed a better efficacy in removing stains from black tea compared to other staining agents. Conclusions The Invisalign® aligners were more prone to pigmentation than the ClearCorrect® or the Minor Tooth Movement® devices after an exposure to coffee or red wine. Black tea caused important stains on the surface of the three tested brands. Both cleansing methods performed similarly.
Collapse
Affiliation(s)
- Gabrielle Bernard
- Department of Oral Health - Orthodontics Section, Faculty of Dental Medicine, Université de Montréal, Québec, Canada
| | - Pierre Rompré
- Department of Oral Health - Orthodontics Section, Faculty of Dental Medicine, Université de Montréal, Québec, Canada
| | - Jason Robert Tavares
- CREPEC, Department of Chemical Engineering, Polytechnique Montréal, P.O. Box 6079, Stat. Centre-Ville, Montréal, Québec, H3C 3A7, Canada.
| | - Andrée Montpetit
- Department of Oral Health - Orthodontics Section, Faculty of Dental Medicine, Université de Montréal, Québec, Canada
| |
Collapse
|
39
|
Bucci R, Rongo R, Levatè C, Michelotti A, Barone S, Razionale AV, D'Antò V. Thickness of orthodontic clear aligners after thermoforming and after 10 days of intraoral exposure: a prospective clinical study. Prog Orthod 2019; 20:36. [PMID: 31495908 PMCID: PMC6732265 DOI: 10.1186/s40510-019-0289-6] [Citation(s) in RCA: 42] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2019] [Accepted: 08/06/2019] [Indexed: 12/18/2022] Open
Abstract
Background Clear aligners (CA) are among the most chosen orthodontic therapies for patients who require an invisible treatment. Previous studies showed that the thermoforming process and the complexity of the intraoral environment might alter the properties of these devices. The aim of the current prospective clinical study was to assess the thickness changes of the CA after 10 days of intraoral use. The secondary aim was to assess the reproducibility of the thermoforming process, in terms of aligner thickness. Materials and methods CA from 18 consecutive patients (13 women, 5 men, mean age 28.8 ± 9.6 years) were investigated. Before intraoral exposure (T0), the thickness of the unused CA was measured at different occlusal points on a 3D model with a dedicated software (Geomagic Qualify 2013; 3D Systems, Rock Hill, SC, USA). Two CA configurations were studied: passive maxillary aligner (P—no tooth movement; no shape for attachments) and active maxillary aligner (A—tooth movement; shape for attachments and divot). The used aligners were returned after 10 days (T1) and the thickness measurements were repeated. A Student’s t test for paired data (T1 vs. T0) was applied to compare the thicknesses of used and unused devices (significance level after Bonferroni correction for multiple comparison was set at p < 0.0014). Furthermore, to study the reproducibility of the thermoforming process, P and A aligners were thermoformed twice, and the thicknesses of the two unused thermoformed devices were compared by means of Student’s t test for paired data (significance level after Bonferroni correction for multiple comparison was set at p < 0.0014) and Dahlberg’s error. Results The thermoforming process showed good reproducibility for both aligner configurations, with a maximum Dahlberg’s error of 0.13 mm. After intraoral use, the thickness of P showed some statistically significant, but not clinically relevant, thickness changes as compared to the unused aligners, while A did not show any significant changes. Conclusion Considering the thickness changes, the thermoforming process is reliable both with active and passive aligner configurations. Also, the CA examined show good thickness stability after physiological intraoral ageing in a population of healthy adults.
Collapse
Affiliation(s)
- Rosaria Bucci
- Department of Neurosciences, Reproductive Sciences and Oral Sciences, University of Naples Federico II, via Pansini 5, 80131, Naples, Italy
| | - Roberto Rongo
- Department of Neurosciences, Reproductive Sciences and Oral Sciences, University of Naples Federico II, via Pansini 5, 80131, Naples, Italy
| | - Carmine Levatè
- Department of Neurosciences, Reproductive Sciences and Oral Sciences, University of Naples Federico II, via Pansini 5, 80131, Naples, Italy
| | - Ambrosina Michelotti
- Department of Neurosciences, Reproductive Sciences and Oral Sciences, University of Naples Federico II, via Pansini 5, 80131, Naples, Italy
| | - Sandro Barone
- Department of Civil and Industrial Engineering, University of Pisa, Largo Lucio Lazzarino 1, 56122, Pisa, Italy
| | - Armando Viviano Razionale
- Department of Civil and Industrial Engineering, University of Pisa, Largo Lucio Lazzarino 1, 56122, Pisa, Italy
| | - Vincenzo D'Antò
- Department of Neurosciences, Reproductive Sciences and Oral Sciences, University of Naples Federico II, via Pansini 5, 80131, Naples, Italy.
| |
Collapse
|
40
|
Condo' R, Pazzini L, Cerroni L, Pasquantonio G, Lagana' G, Pecora A, Mussi V, Rinaldi A, Mecheri B, Licoccia S, Maiolo L. Mechanical properties of "two generations" of teeth aligners: Change analysis during oral permanence. Dent Mater J 2018; 37:835-842. [PMID: 29998941 DOI: 10.4012/dmj.2017-323] [Citation(s) in RCA: 32] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
Aim of this in vitro study was to analyze structural properties of two different polymeric orthodontic aligners, Exceed30 (EX30) and Smart Track (LD30), before and after use. Forty patterns of aligners were randomly selected: 20 LD30 and 20 EX30, worn intra-orally for 14±3 days, 22 h/day. From each aligner, 10 specimens were prepared from buccal surfaces of the incisor region by the cutting of samples 5×5 mm under a stereomicroscope. All samples were subjected to Fourier transform infrared spectroscopy, micro-Raman spectroscopy, X-ray diffraction, tensile and indentation strength test. LD30 appeared more homogeneous, with a crystalline fraction lower than EX30 and exhibited a higher elastic behavior and a lower tendency to warp after use than EX30. LD30 demonstrated better adaptability to the dental arch and greater consistency of application of orthodontic forces than produced with EX30. However, both materials showed structural modifications that resulted in increased sample hardness and hyper-plasticity.
Collapse
Affiliation(s)
- Roberta Condo'
- Department of Clinical Sciences and Translational Medicine, University of Rome "Tor Vergata", Via Montpellier
| | - Luca Pazzini
- Institute for Microelectronics and Microsystems -National Research Council (IMM-CNR) Via del Fosso del Cavaliere
| | - Loredana Cerroni
- Department of Clinical Sciences and Translational Medicine, University of Rome "Tor Vergata", Via Montpellier
| | - Guido Pasquantonio
- Department of Clinical Sciences and Translational Medicine, University of Rome "Tor Vergata", Via Montpellier
| | - Giuseppina Lagana'
- Department of Clinical Sciences and Translational Medicine, University of Rome "Tor Vergata", Via Montpellier
| | - Alessandro Pecora
- Institute for Microelectronics and Microsystems -National Research Council (IMM-CNR) Via del Fosso del Cavaliere
| | - Valentina Mussi
- Institute of Complex Systems -National Research Council (ISC-CNR) Via del Fosso del Cavaliere
| | - Antonio Rinaldi
- ENEA -Technical Unit for Material Technologies (UTTMAT) Casaccia Research Center, Via Anguillarese
| | - Barbara Mecheri
- Department of Chemical Science and Technology, University of Rome "Tor Vergata"
| | - Silvia Licoccia
- Department of Chemical Science and Technology, University of Rome "Tor Vergata"
| | - Luca Maiolo
- Institute for Microelectronics and Microsystems -National Research Council (IMM-CNR) Via del Fosso del Cavaliere
| |
Collapse
|
41
|
Zafeiriadis AA, Karamouzos A, Athanasiou AE, Eliades T, Palaghias G. An in vivo spectrophotometric evaluation of Vivera® and Essix® clear thermoplastic retainer discolouration. AUSTRALASIAN ORTHODONTIC JOURNAL 2018. [DOI: 10.21307/aoj-2020-053] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Abstract
Aim
To assess the in vivo colour alterations of two different clear thermoplastic retainers.
Methods
Thirty patients were randomly allocated into two Groups (N = 15) following the completion of active orthodontic treatment. Group 1 received Vivera® and Group 2 Essix® C+ thermoplastic retainers. Each patient was provided with two fabricated retainers (one for use and the other to serve as a control). The CIELAB parameters of the patients’ upper central incisors were measured with a SpectroShade™ spectrophotometer immediately after retainer placement (T0) and again after 15 days (T1), one month (T2) and three months (T3). The measurements were also performed on teeth without the retainer in place. ΔE differences were calculated.
Methods
ΔE changes from T0 to Tp T2 or T3 showed no statistically significant differences between Groups 1 and 2 within any combination of measurements or teeth. ΔEļŢ3-Ţ0ļ changes for used retainers were 1.55 times higher than control appliances (p = 0.002) and 1.44 times higher than for teeth-only (p = 0.004). For used retainers, changes between T3 and T0 were 1.56 times higher than between T and T0 and 1.47 higher than between T2 and T0 (p < 0.001). There were no statistically significant differences in ΔE between teeth 11 and 21.
Results
Used retainers exhibited greater colour change than control appliances or teeth-only readings, and increased commensurate with the duration of use. Vivera® and Essix® retainers exhibited similar colour stability. All differences observed were considered clinically acceptable (ΔE < 3.7), although prolonged use could cause clinically significant colour changes.
Collapse
Affiliation(s)
- Anastasios A Zafeiriadis
- Department of Orthodontics , Faculty of Dentistry, School of Health Sciences, Aristotle University of Thessaloniki , Thessaloniki , Greece
| | - Andreas Karamouzos
- Department of Orthodontics , Faculty of Dentistry, School of Health Sciences, Aristotle University of Thessaloniki , Thessaloniki , Greece
| | - Athanasios E Athanasiou
- Hamdan Bin Mohammed College of Dental Medicine, Mohammed Bin Rashid University of Medicine and Health Sciences , Dubai , United Arab Emirates
| | - Theodore Eliades
- Clinic of Orthodontics and Pediatric Dentistry, Center of Dental Medicine, University of Zurich , Zurich , Switzerland
| | - George Palaghias
- Departments of Basic Dental Sciences and Operative Dentistry, Faculty of Dentistry, School of Health Sciences, Aristotle University of Thessaloniki , Thessaloniki , Greece
| |
Collapse
|
42
|
Paszkiewicz S, Szymczyk A, Pawlikowska D, Irska I, Taraghi I, Pilawka R, Gu J, Li X, Tu Y, Piesowicz E. Synthesis and characterization of poly(ethylene terephthalate-co-1,4-cyclohexanedimethylene terephtlatate)-block-poly(tetramethylene oxide) copolymers. RSC Adv 2017. [DOI: 10.1039/c7ra07172h] [Citation(s) in RCA: 47] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023] Open
Abstract
A series of PETG-block-PTMO copolymers were synthesized by means of a polycondensation process and characterized using1H nuclear magnetic resonance and Fourier transform infrared spectroscopy, that confirm the successful synthesis of the material.
Collapse
Affiliation(s)
- Sandra Paszkiewicz
- West Pomeranian University of Technology
- Institute of Materials Science and Engineering
- 70310 Szczecin
- Poland
| | - Anna Szymczyk
- West Pomeranian University of Technology
- Institute of Physics
- 70311 Szczecin
- Poland
| | - Daria Pawlikowska
- West Pomeranian University of Technology
- Institute of Materials Science and Engineering
- 70310 Szczecin
- Poland
| | - Izabela Irska
- West Pomeranian University of Technology
- Institute of Materials Science and Engineering
- 70310 Szczecin
- Poland
| | - Iman Taraghi
- West Pomeranian University of Technology
- Institute of Materials Science and Engineering
- 70310 Szczecin
- Poland
- Semnam University
| | - Ryszard Pilawka
- West Pomeranian University of Technology
- Polymer Institute
- 70322 Szczecin
- Poland
- New Era Materials Sp. z o.o
| | - Jiali Gu
- College of Soochow University
- Suzhou 215123
- China
| | - Xiaohong Li
- College of Soochow University
- Suzhou 215123
- China
| | - Yingfeng Tu
- College of Soochow University
- Suzhou 215123
- China
| | - Elzbieta Piesowicz
- West Pomeranian University of Technology
- Institute of Materials Science and Engineering
- 70310 Szczecin
- Poland
| |
Collapse
|