1
|
Mortelmans T, Marty B, Kazazis D, Padeste C, Li X, Ekinci Y. Three-Dimensional Microfluidic Capillary Device for Rapid and Multiplexed Immunoassays in Whole Blood. ACS Sens 2024; 9:2455-2464. [PMID: 38687557 PMCID: PMC11129352 DOI: 10.1021/acssensors.4c00153] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2024] [Revised: 04/11/2024] [Accepted: 04/16/2024] [Indexed: 05/02/2024]
Abstract
In this study, we demonstrate whole blood immunoassays using a microfluidic device optimized for conducting rapid and multiplexed fluorescence-linked immunoassays. The device is capable of handling whole blood samples without any preparatory treatment. The three-dimensional channels in poly(methyl methacrylate) are designed to passively load bodily fluids and, due to their linearly tapered profile, facilitate size-dependent immobilization of biofunctionalized particles. The channel geometry is optimized to allow for the unimpeded flow of cellular constituents such as red blood cells (RBCs). Additionally, to make the device easier to operate, the biofunctionalized particles are pretrapped in a first step, and the channel is dried under vacuum, after which it can be loaded with the biological sample. This novel approach and design eliminated the need for traditionally laborious steps such as filtering, incubation, and washing steps, thereby substantially simplifying the immunoassay procedures. Moreover, by leveraging the shallow device dimensions, we show that sample loading to read-out is possible within 5 min. Our results also show that the presence of RBCs does not compromise the sensitivity of the assays when compared to those performed in a pure buffer solution. This highlights the practical adaptability of the device for simple and rapid whole-blood assays. Lastly, we demonstrate the device's multiplexing capability by pretrapping particles of different sizes, each functionalized with a different antigen, thus enabling the performance of multiplexed on-chip whole-blood immunoassays, showcasing the device's versatility and effectiveness toward low-cost, simple, and multiplexed sensing of biomarkers and pathogens directly in whole blood.
Collapse
Affiliation(s)
- Thomas Mortelmans
- Laboratory for X-ray Nanoscience and Technologies, 5232 Villigen, Switzerland
- Swiss Nanoscience Institute, University of Basel, 4056 Basel, Switzerland
| | - Balz Marty
- Laboratory for X-ray Nanoscience and Technologies, 5232 Villigen, Switzerland
| | - Dimitrios Kazazis
- Laboratory for X-ray Nanoscience and Technologies, 5232 Villigen, Switzerland
| | - Celestino Padeste
- Laboratory of Nanoscale Biology, Paul Scherrer Institute, 5232 Villigen, Switzerland
| | - Xiaodan Li
- Laboratory of Biomolecular Research, Paul Scherrer Institute, 5232 Villigen, Switzerland
| | - Yasin Ekinci
- Laboratory for X-ray Nanoscience and Technologies, 5232 Villigen, Switzerland
| |
Collapse
|
2
|
Shahbaz M, Butt MA, Piramidowicz R. Breakthrough in Silicon Photonics Technology in Telecommunications, Biosensing, and Gas Sensing. MICROMACHINES 2023; 14:1637. [PMID: 37630173 PMCID: PMC10456798 DOI: 10.3390/mi14081637] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/02/2023] [Revised: 08/17/2023] [Accepted: 08/18/2023] [Indexed: 08/27/2023]
Abstract
Silicon photonics has been an area of active research and development. Researchers have been working on enhancing the integration density and intricacy of silicon photonic circuits. This involves the development of advanced fabrication techniques and novel designs to enable more functionalities on a single chip, leading to higher performance and more efficient systems. In this review, we aim to provide a brief overview of the recent advancements in silicon photonic devices employed for telecommunication and sensing (biosensing and gas sensing) applications.
Collapse
Affiliation(s)
| | - Muhammad A. Butt
- Institute of Microelectronics and Optoelectronics, Warsaw University of Technology, Koszykowa 75, 00-662 Warszawa, Poland
| | | |
Collapse
|
3
|
Ben Mariem I, Kaziz S, Belkhiria M, Echouchene F, Belmabrouk H. Numerical optimization of microfluidic biosensor detection time for the SARS-CoV-2 using the Taguchi method. INDIAN JOURNAL OF PHYSICS AND PROCEEDINGS OF THE INDIAN ASSOCIATION FOR THE CULTIVATION OF SCIENCE (2004) 2023; 97:1-8. [PMID: 37361718 PMCID: PMC10008012 DOI: 10.1007/s12648-023-02632-z] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/23/2022] [Accepted: 02/06/2023] [Indexed: 05/20/2023]
Abstract
The performance of microfluidic biosensor of the SARS-Cov-2 was numerically analyzed through finite element method. The calculation results have been validated with comparison with experimental data reported in the literature. The novelty of this study is the use of the Taguchi method in the optimization analysis, and an L8(25) orthogonal table of five critical parameters-Reynolds number (Re), Damköhler number (Da), relative adsorption capacity (σ), equilibrium dissociation constant (KD), and Schmidt number (Sc), with two levels was designed. ANOVA methods are used to obtain the significance of key parameters. The optimal combination of the key parameters is Re = 10-2, Da = 1000, σ = 0.2, KD = 5, and Sc 104 to achieve the minimum response time (0.15). Among the selected key parameters, the relative adsorption capacity (σ) has the highest contribution (42.17%) to the reduction of the response time, while the Schmidt number (Sc) has the lowest contribution (5.19%). The presented simulation results are useful in designing microfluidic biosensors in order to reduce their response time.
Collapse
Affiliation(s)
- Ibrahim Ben Mariem
- Electronic and Microelectronics Lab, Department of Physics, Faculty of Science of Monastir, University of Monastir, 5019 Monastir, Tunisia
| | - Sameh Kaziz
- Quantum and Statistical Physics Laboratory, Faculty of Sciences of Monastir, University of Monastir, Environment Boulevard, 5019 Monastir, Tunisia
- Higher National Engineering School of Tunis, Taha Hussein Montfleury Boulevard, University of Tunis, 1008 Tunis, Tunisia
| | - Maissa Belkhiria
- Electronic and Microelectronics Lab, Department of Physics, Faculty of Science of Monastir, University of Monastir, 5019 Monastir, Tunisia
| | - Fraj Echouchene
- Electronic and Microelectronics Lab, Department of Physics, Faculty of Science of Monastir, University of Monastir, 5019 Monastir, Tunisia
- Higher Institute of Applied Sciences and Technology of Soussse, University of Sousse, Sousse, Tunisia
| | - Hafedh Belmabrouk
- Electronic and Microelectronics Lab, Department of Physics, Faculty of Science of Monastir, University of Monastir, 5019 Monastir, Tunisia
- Department of Physics, College of Science at Zulfi, Majmaah University, Al Majma’ah, 11952 Saudi Arabia
| |
Collapse
|
4
|
Allameh S, Rabbani M. A Distance-Based Microfluidic Paper-Based Biosensor for Glucose Measurements in Tear Range. Appl Biochem Biotechnol 2022; 194:2077-2092. [PMID: 35029790 DOI: 10.1007/s12010-022-03817-8] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 12/31/2021] [Indexed: 11/29/2022]
Abstract
The prevalence of diabetes has increased over the past years. Therefore, developing minimally invasive, user-friendly, and cost-effective glucose biosensors is necessary especially in low-income and developing countries. Cellulose paper-based analytical devices have attracted the attention of many researchers due to affordability, not requiring trained personnel, and complex equipment. This paper describes a microfluidic paper-based analytical device (μPAD) for detecting glucose concentration in tear range with the naked eye. The paper-based biosensor fabricated by laser CO2; and glucose oxidase/horseradish peroxidase (GOx/HRP) enzyme solution coupled with tetramethylbenzidine (TMB) were utilized as reagents. A sample volume of 10 μl was needed for the biosensor operation and the results were observable within 5 min. The color intensity-based and distance-based results were analyzed by ImageJ and Tracker to evaluate the device performance. Distance-based results showed a linear behavior in 0.1-1.2 mM with an R2 = 0.9962 and limit of detection (LOD) of 0.1 mM. The results could be perceived by the naked eye without needing additional equipment or trained personnel in a relatively short time (3-5 min).
Collapse
Affiliation(s)
- Samira Allameh
- Department of Biomedical Engineering, Faculty of Engineering, University of Isfahan, Isfahan, Iran
| | - Mohsen Rabbani
- Department of Biomedical Engineering, Faculty of Engineering, University of Isfahan, Isfahan, Iran.
| |
Collapse
|
5
|
Kaziz S, Ben Mariem I, Echouchene F, Belkhiria M, Belmabrouk H. Taguchi optimization of integrated flow microfluidic biosensor for COVID-19 detection. EUROPEAN PHYSICAL JOURNAL PLUS 2022; 137:1235. [PMID: 36405040 PMCID: PMC9660129 DOI: 10.1140/epjp/s13360-022-03457-1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/19/2022] [Accepted: 10/17/2022] [Indexed: 05/20/2023]
Abstract
In this research, Taguchi's method was employed to optimize the performance of a microfluidic biosensor with an integrated flow confinement for rapid detection of the SARS-CoV-2. The finite element method was used to solve the physical model which has been first validated by comparison with experimental results. The novelty of this study is the use of the Taguchi approach in the optimization analysis. An L 8 2 7 orthogonal array of seven critical parameters-Reynolds number (Re), Damköhler number (Da), relative adsorption capacity ( σ ), equilibrium dissociation constant (KD), Schmidt number (Sc), confinement coefficient (α) and dimensionless confinement position (X), with two levels was designed. Analysis of variance (ANOVA) methods are also used to calculate the contribution of each parameter. The optimal combination of these key parameters was Re = 10-2, Da = 1000, σ = 0.5, K D = 5, Sc = 105, α = 2 and X = 2 to achieve the lowest dimensionless response time (0.11). Among the all-optimization factors, the relative adsorption capacity ( σ ) has the highest contribution (37%) to the reduction of the response time, while the Schmidt number (Sc) has the lowest contribution (7%).
Collapse
Affiliation(s)
- Sameh Kaziz
- Quantum and Statistical Physics Laboratory, Faculty of Sciences of Monastir, University of Monastir, Environment Boulevard, 5019 Monastir, Tunisia
- Higher National Engineering School of Tunis, Taha Hussein Montfleury Boulevard, University of Tunis, 1008 Tunis, Tunisia
| | - Ibrahim Ben Mariem
- Quantum and Statistical Physics Laboratory, Faculty of Sciences of Monastir, University of Monastir, Environment Boulevard, 5019 Monastir, Tunisia
| | - Fraj Echouchene
- Laboratory of Electronics and Microelectronics, Faculty of Science of Monastir, University of Monastir, Environment Boulevard, 5019 Monastir, Tunisia
- Higher Institute of Applied Sciences and Technology of Sousse, University of Sousse, Sousse, Tunisia
| | - Maissa Belkhiria
- Laboratory of Electronics and Microelectronics, Faculty of Science of Monastir, University of Monastir, Environment Boulevard, 5019 Monastir, Tunisia
| | - Hafedh Belmabrouk
- Department of Physics, College of Science at Zulfi, Majmaah University, Al Majma’ah, Saudi Arabia
| |
Collapse
|
6
|
Kaziz S, Ben Mariem I, Echouchene F, Gazzah MH, Belmabrouk H. Design parameters optimization of an electrothermal flow biosensor for the SARS-CoV-2 S protein immunoassay. INDIAN JOURNAL OF PHYSICS AND PROCEEDINGS OF THE INDIAN ASSOCIATION FOR THE CULTIVATION OF SCIENCE (2004) 2022; 96:4091-4101. [PMID: 35463477 PMCID: PMC9013635 DOI: 10.1007/s12648-022-02360-w] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/03/2022] [Accepted: 03/25/2022] [Indexed: 05/20/2023]
Abstract
To combat the coronavirus disease 2019 (COVID-19), great efforts have been made by scientists around the world to improve the performance of detection devices so that they can efficiently and quickly detect the virus responsible for this disease. In this context we performed 2D finite element simulation on the kinetics of SARS-CoV-2 S protein binding reaction of a biosensor using the alternating current electrothermal (ACET) effect. The ACET flow can produce vortex patterns, thereby improving the transportation of the target analyte to the binding surface and thus enhancing the performance of the biosensor. Optimization of some design parameters concerning the microchannel height and the reaction surface, such as its length as well as its position on the top wall of the microchannel, in order to improve the biosensor efficiency, was studied. The results revealed that the detection time can be improved by 55% with an applied voltage of 10 V rms and an operating frequency of 150 kHz and that the decrease in the height of the microchannel and in the length of the binding surface can lead to an increase in the rate of the binding reaction and therefore decrease the biosensor response time. Also, moving the sensitive surface from an optimal position, located in front of the electrodes, decreases the performance of the device.
Collapse
Affiliation(s)
- Sameh Kaziz
- Quantum and Statistical Physics Laboratory, Faculty of Sciences of Monastir, University of Monastir, Environment Boulevard, 5019 Monastir, Tunisia
- Higher National Engineering School of Tunis, Taha Hussein Montfleury Boulevard, University of Tunis, 1008 Tunis, Tunisia
| | - Ibrahim Ben Mariem
- Quantum and Statistical Physics Laboratory, Faculty of Sciences of Monastir, University of Monastir, Environment Boulevard, 5019 Monastir, Tunisia
| | - Fraj Echouchene
- Laboratory of Electronics and Microelectronics, Faculty of Science of Monastir, University of Monastir, Environment Boulevard, 5019 Monastir, Tunisia
| | - Mohamed Hichem Gazzah
- Quantum and Statistical Physics Laboratory, Faculty of Sciences of Monastir, University of Monastir, Environment Boulevard, 5019 Monastir, Tunisia
| | - Hafedh Belmabrouk
- Laboratory of Electronics and Microelectronics, Faculty of Science of Monastir, University of Monastir, Environment Boulevard, 5019 Monastir, Tunisia
- Department of Physics, College of Science at Al Zulfi, Majmaah University, Al Majma’ah, 11952 Saudi Arabia
| |
Collapse
|
7
|
Kaziz S, Saad Y, Gazzah MH, Belmabrouk H. 3D simulation of microfluidic biosensor for SARS-CoV-2 S protein binding kinetics using new reaction surface design. EUROPEAN PHYSICAL JOURNAL PLUS 2022; 137:241. [PMID: 35194535 PMCID: PMC8854486 DOI: 10.1140/epjp/s13360-022-02470-8] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/06/2021] [Accepted: 02/10/2022] [Indexed: 05/05/2023]
Abstract
In this study, we performed 3D finite element simulations on the binding reaction kinetics of SARS-CoV-2 S protein (target analyte) and its corresponding immobilized antibody (ligand) in a heterogeneous microfluidic immunoassay. Two types of biosensors with two different shapes and geometries of the reaction surface and electrodes were studied. Alternating current electrothermal (ACET) force was applied to improve the binding efficiency of the biomolecular pairs by accelerating the transport of analytes to the binding surface. The ACET force stirs the flow field, thereby reducing the thickness of the diffusion boundary layer, often developed on the reaction surface due to the slow flow velocity, low analyte diffusion coefficient, and surface reaction high rate. The results showed that the detection time of one of the biosensors can be improved by 69% under an applied voltage of 10 Vrms and an operating frequency of 100 kHz. Certain control factors such as the thermal boundary conditions as well as the electrical conductivity of the buffer solution were analyzed in order to find the appropriate values to improve the efficiency of the biosensor.
Collapse
Affiliation(s)
- Sameh Kaziz
- Quantum and Statistical Physics Laboratory, Faculty of Sciences of Monastir, University of Monastir, Environment Boulevard, 5019 Monastir, Tunisia
- Higher National Engineering School of Tunis, Taha Hussein Montfleury Boulevard, University of Tunis, 1008 Tunis, Tunisia
| | - Yosra Saad
- Quantum and Statistical Physics Laboratory, Faculty of Sciences of Monastir, University of Monastir, Environment Boulevard, 5019 Monastir, Tunisia
| | - Mohamed Hichem Gazzah
- Quantum and Statistical Physics Laboratory, Faculty of Sciences of Monastir, University of Monastir, Environment Boulevard, 5019 Monastir, Tunisia
| | - Hafedh Belmabrouk
- Laboratory of Electronics and Microelectronics, Faculty of Science of Monastir, University of Monastir, Environment Boulevard, 5019 Monastir, Tunisia
- Department of Physics, College of Science at Al Zulfi, Majmaah University, Al Majmaah, 11952 Saudi Arabia
| |
Collapse
|
8
|
Sathish S, Shen AQ. Toward the Development of Rapid, Specific, and Sensitive Microfluidic Sensors: A Comprehensive Device Blueprint. JACS AU 2021; 1:1815-1833. [PMID: 34841402 PMCID: PMC8611667 DOI: 10.1021/jacsau.1c00318] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/20/2021] [Indexed: 05/04/2023]
Abstract
Recent advances in nano/microfluidics have led to the miniaturization of surface-based chemical and biochemical sensors, with applications ranging from environmental monitoring to disease diagnostics. These systems rely on the detection of analytes flowing in a liquid sample, by exploiting their innate nature to react with specific receptors immobilized on the microchannel walls. The efficiency of these systems is defined by the cumulative effect of analyte detection speed, sensitivity, and specificity. In this perspective, we provide a fresh outlook on the use of important parameters obtained from well-characterized analytical models, by connecting the mass transport and reaction limits with the experimentally attainable limits of analyte detection efficiency. Specifically, we breakdown when and how the operational (e.g., flow rates, channel geometries, mode of detection, etc.) and molecular (e.g., receptor affinity and functionality) variables can be tailored to enhance the analyte detection time, analytical specificity, and sensitivity of the system (i.e., limit of detection). Finally, we present a simple yet cohesive blueprint for the development of high-efficiency surface-based microfluidic sensors for rapid, sensitive, and specific detection of chemical and biochemical analytes, pertinent to a variety of applications.
Collapse
Affiliation(s)
- Shivani Sathish
- Micro/Bio/Nanofluidics Unit, Okinawa Institute of Science and Technology Graduate
University, 1919-1 Tancha, Onna-son, Okinawa 904-0495, Japan
| | - Amy Q. Shen
- Micro/Bio/Nanofluidics Unit, Okinawa Institute of Science and Technology Graduate
University, 1919-1 Tancha, Onna-son, Okinawa 904-0495, Japan
| |
Collapse
|
9
|
Saftics A, Kurunczi S, Peter B, Szekacs I, Ramsden JJ, Horvath R. Data evaluation for surface-sensitive label-free methods to obtain real-time kinetic and structural information of thin films: A practical review with related software packages. Adv Colloid Interface Sci 2021; 294:102431. [PMID: 34330074 DOI: 10.1016/j.cis.2021.102431] [Citation(s) in RCA: 22] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2020] [Revised: 04/16/2021] [Accepted: 04/18/2021] [Indexed: 02/07/2023]
Abstract
Interfacial layers are important in a wide range of applications in biomedicine, biosensing, analytical chemistry and the maritime industries. Given the growing number of applications, analysis of such layers and understanding their behavior is becoming crucial. Label-free surface sensitive methods are excellent for monitoring the formation kinetics, structure and its evolution of thin layers, even at the nanoscale. In this paper, we review existing and commercially available label-free techniques and demonstrate how the experimentally obtained data can be utilized to extract kinetic and structural information during and after formation, and any subsequent adsorption/desorption processes. We outline techniques, some traditional and some novel, based on the principles of optical and mechanical transduction. Our special focus is the current possibilities of combining label-free methods, which is a powerful approach to extend the range of detected and deduced parameters. We summarize the most important theoretical considerations for obtaining reliable information from measurements taking place in liquid environments and, hence, with layers in a hydrated state. A thorough treamtmaent of the various kinetic and structural quantities obtained from evaluation of the raw label-free data are provided. Such quantities include layer thickness, refractive index, optical anisotropy (and molecular orientation derived therefrom), degree of hydration, viscoelasticity, as well as association and dissociation rate constants and occupied area of subsequently adsorbed species. To demonstrate the effect of variations in model conditions on the observed data, simulations of kinetic curves at various model settings are also included. Based on our own extensive experience with optical waveguide lightmode spectroscopy (OWLS) and the quartz crystal microbalance (QCM), we have developed dedicated software packages for data analysis, which are made available to the scientific community alongside this paper.
Collapse
|
10
|
Analysis of Temperature-Jump Boundary Conditions on Heat Transfer for Heterogeneous Microfluidic Immunosensors. SENSORS 2021; 21:s21103502. [PMID: 34069780 PMCID: PMC8157299 DOI: 10.3390/s21103502] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/08/2020] [Revised: 01/13/2021] [Accepted: 01/28/2021] [Indexed: 12/20/2022]
Abstract
The objective of the current study is to analyze numerically the effect of the temperature-jump boundary condition on heterogeneous microfluidic immunosensors under electrothermal force. A three-dimensional simulation using the finite element method on the binding reaction kinetics of C-reactive protein (CRP) was performed. The kinetic reaction rate was calculated with coupled Laplace, Navier−Stokes, energy, and mass diffusion equations. Two types of reaction surfaces were studied: one in the form of a disc surrounded by two electrodes and the other in the form of a circular ring, one electrode is located inside the ring and the other outside. The numerical results reveal that the performance of a microfluidic biosensor is enhanced by using the second design of the sensing area (circular ring) coupled with the electrothermal force. The improvement factor under the applied ac field 15 Vrms was about 1.2 for the first geometry and 3.6 for the second geometry. Furthermore, the effect of temperature jump on heat transfer rise and response time was studied. The effect of two crucial parameters, viz. Knudsen number (Kn) and thermal accommodation coefficient (σT) with and without electrothermal effect, were analyzed for the two configurations.
Collapse
|
11
|
Kim N, Han K, Su PC, Kim I, Yoon YJ. A rotationally focused flow (RFF) microfluidic biosensor by density difference for early-stage detectable diagnosis. Sci Rep 2021; 11:9277. [PMID: 33927298 PMCID: PMC8085145 DOI: 10.1038/s41598-021-88647-0] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2020] [Accepted: 03/12/2021] [Indexed: 02/07/2023] Open
Abstract
Label-free optical biosensors have received tremendous attention in point-of-care testing, especially in the emerging pandemic, COVID-19, since they advance toward early-detection, rapid, real-time, ease-of-use, and low-cost paradigms. Protein biomarkers testings require less sample modification process compared to nucleic-acid biomarkers'. However, challenges always are in detecting low-concentration for early-stage diagnosis. Here we present a Rotationally Focused Flow (RFF) method to enhance sensitivity(wavelength shift) of label-free optical sensors by increasing the detection probability of protein-based molecules. The RFF is structured by adding a less-dense fluid to focus the target-fluid in a T-shaped microchannel. It is integrated with label-free silicon microring resonators interacting with biotin-streptavidin. The suggested mechanism has demonstrated 0.19 fM concentration detection along with a significant magnitudes sensitivity enhancement compared to single flow methods. Verified by both CFD simulations and fluorescent flow-experiments, this study provides a promising proof-of-concept platform for next-generation lab-on-a-chip bioanalytics such as ultrafast and early-detection of COVID-19.
Collapse
Affiliation(s)
- Noori Kim
- Department of Electrical and Electronic Engineering, Newcastle University in Singapore, 172A Ang Mo Kio Avenue 8, 05-01 SIT@NYP Building, Singapore, 567739, Singapore
- School of Mechanical and Aerospace Engineering, Nanyang Technological University (NTU), Singapore, 639798, Singapore
| | - Kyungsup Han
- School of Mechanical and Aerospace Engineering, Nanyang Technological University (NTU), Singapore, 639798, Singapore
| | - Pei-Chen Su
- School of Mechanical and Aerospace Engineering, Nanyang Technological University (NTU), Singapore, 639798, Singapore
| | - Insup Kim
- Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon, 34141, Korea
| | - Yong-Jin Yoon
- School of Mechanical and Aerospace Engineering, Nanyang Technological University (NTU), Singapore, 639798, Singapore.
- Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon, 34141, Korea.
| |
Collapse
|
12
|
Kaziz S, Saad Y, Bouzid M, Selmi M, Belmabrouk H. Enhancement of COVID-19 detection time by means of electrothermal force. MICROFLUIDICS AND NANOFLUIDICS 2021; 25:86. [PMID: 34548854 PMCID: PMC8446728 DOI: 10.1007/s10404-021-02490-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/27/2021] [Accepted: 09/05/2021] [Indexed: 05/04/2023]
Abstract
The rapid spread and quick transmission of the new ongoing pandemic coronavirus disease 2019 (COVID-19) has urged the scientific community to looking for strong technology to understand its pathogenicity, transmission, and infectivity, which helps in the development of effective vaccines and therapies. Furthermore, there was a great effort to improve the performance of biosensors so that they can detect the pathogenic virus quickly, in reliable and precise way. In this context, we propose a numerical simulation to highlight the important role of the design parameters that can significantly improve the performance of the biosensor, in particular the sensitivity as well as the detection limit. Applied alternating current electrothermal (ACET) force can generate swirling patterns in the fluid within the microfluidic channel, which improve the transport of target molecule toward the reaction surface and, thus, enhance the response time of the biosensor. In this work, the ACET effect on the SARS-CoV-2 S protein binding reaction kinetics and on the detection time of the biosensor was analyzed. Appropriate choice of electrodes location on the walls of the microchannel and suitable values of the dissociation and association rates of the binding reaction, while maintaining the same affinity, with and without ACET effect, are also, discussed to enhance the total performance of the biosensor and reduce its response time. The two-dimensional equations system is solved by the finite element approach. The best performance of the biosensor is obtained in the case where the response time decreased by 61% with AC applying voltage.
Collapse
Affiliation(s)
- Sameh Kaziz
- Quantum and Statistical Physics Laboratory, Faculty of Sciences of Monastir, University of Monastir, Environment Boulevard, 5019 Monastir, Tunisia
- Higher National Engineering School of Tunis, Taha Hussein Montfleury Boulevard, University of Tunis, 1008 Tunis, Tunisia
| | - Yosra Saad
- Quantum and Statistical Physics Laboratory, Faculty of Sciences of Monastir, University of Monastir, Environment Boulevard, 5019 Monastir, Tunisia
| | - Mohamed Bouzid
- Quantum and Statistical Physics Laboratory, Faculty of Sciences of Monastir, University of Monastir, Environment Boulevard, 5019 Monastir, Tunisia
| | - Marwa Selmi
- Department of Radiological Sciences and Medical Imaging, College of Applied Medical Sciences, Majmaah University, AlMajmaah, 11952 Saudi Arabia
- Laboratory of Electronics and Microelectronics, Faculty of Science of Monastir, University of Monastir, Environment Boulevard, 5019 Monastir, Tunisia
| | - Hafedh Belmabrouk
- Laboratory of Electronics and Microelectronics, Faculty of Science of Monastir, University of Monastir, Environment Boulevard, 5019 Monastir, Tunisia
- Department of Physics, College of Science at Al Zulfi, Majmaah University, AlMajmaah, Saudi Arabia
| |
Collapse
|
13
|
Shahbazi F, Jabbari M, Esfahani MN, Keshmiri A. A computational simulation platform for designing real-time monitoring systems with application to COVID-19. Biosens Bioelectron 2021; 171:112716. [PMID: 33068880 PMCID: PMC7550051 DOI: 10.1016/j.bios.2020.112716] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2020] [Revised: 07/29/2020] [Accepted: 10/07/2020] [Indexed: 12/18/2022]
Abstract
With the aim of contributing to the fight against the coronavirus disease 2019 (COVID-19), numerous strategies have been proposed. While developing an effective vaccine can take months up to years, detection of infected patients seems like one of the best ideas for controlling the situation. The role of biosensors in containing highly pathogenic viruses, saving lives and economy is evident. A new competitive numerical platform specifically for designing microfluidic-integrated biosensors is developed and presented in this work. Properties of the biosensor, sample, buffer fluid and even the microfluidic channel can be modified in this model. This feature provides the scientific community with the ability to design a specific biosensor for requested point-of-care (POC) applications. First, the validation of the presented numerical platform against experimental data and then results and discussion, highlighting the important role of the design parameters on the performance of the biosensor is presented. For the latter, the baseline case has been set on the previous studies on the biosensors suitable for SARS-CoV, which has the highest similarity to the 2019 nCoV. Subsequently, the effects of concentration of the targeted molecules in the sample, installation position and properties of the biosensor on its performance were investigated in 11 case studies. The presented numerical framework provides an insight into understanding of the virus reaction in the design process of the biosensor and enhances our preparation for any future outbreaks. Furthermore, the integration of biosensors with different devices for accelerating the process of defeating the pandemic is proposed.
Collapse
Affiliation(s)
- Fatemeh Shahbazi
- Department of Mechanical, Aerospace and Civil Engineering, University of Manchester, Manchester, M13 9PL, UK
| | - Masoud Jabbari
- Department of Mechanical, Aerospace and Civil Engineering, University of Manchester, Manchester, M13 9PL, UK
| | | | - Amir Keshmiri
- Department of Mechanical, Aerospace and Civil Engineering, University of Manchester, Manchester, M13 9PL, UK; Manchester University NHS Foundation Trust, Manchester Academic Health Science Centre, Southmoor Road, Wythenshawe, Manchester, M13 9PL, UK.
| |
Collapse
|
14
|
Piroozmand F, Mohammadipanah F, Faridbod F. Emerging biosensors in detection of natural products. Synth Syst Biotechnol 2020; 5:293-303. [PMID: 32954023 PMCID: PMC7484522 DOI: 10.1016/j.synbio.2020.08.002] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2020] [Revised: 08/23/2020] [Accepted: 08/25/2020] [Indexed: 01/10/2023] Open
Abstract
Natural products (NPs) are a valuable source in the food, pharmaceutical, agricultural, environmental, and many other industrial sectors. Their beneficial properties along with their potential toxicities make the detection, determination or quantification of NPs essential for their application. The advanced instrumental methods require time-consuming sample preparation and analysis. In contrast, biosensors allow rapid detection of NPs, especially in complex media, and are the preferred choice of detection when speed and high throughput are intended. Here, we review diverse biosensors reported for the detection of NPs. The emerging approaches for improving the efficiency of biosensors, such as microfluidics, nanotechnology, and magnetic beads, are also discussed. The simultaneous use of two detection techniques is suggested as a robust strategy for precise detection of a specific NP with structural complexity in complicated matrices. The parallel detection of a variety of NPs structures or biological activities in a mixture of extract in a single detection phase is among the anticipated future advancements in this field which can be achieved using multisystem biosensors applying multiple flow cells, sensing elements, and detection mechanisms on miniaturized folded chips.
Collapse
Affiliation(s)
- Firoozeh Piroozmand
- Pharmaceutical Biotechnology Lab, Department of Microbial Biotechnology, School of Biology and Center of Excellence in Phylogeny of Living Organisms, College of Science, University of Tehran, 14155-6455, Tehran, Iran
| | - Fatemeh Mohammadipanah
- Pharmaceutical Biotechnology Lab, Department of Microbial Biotechnology, School of Biology and Center of Excellence in Phylogeny of Living Organisms, College of Science, University of Tehran, 14155-6455, Tehran, Iran
| | - Farnoush Faridbod
- Center of Excellence in Electrochemistry, School of Chemistry, College of Science, University of Tehran, Tehran, Iran
| |
Collapse
|
15
|
Selmi M, Belmabrouk H. AC Electroosmosis Effect on Microfluidic Heterogeneous Immunoassay Efficiency. MICROMACHINES 2020; 11:mi11040342. [PMID: 32218325 PMCID: PMC7230709 DOI: 10.3390/mi11040342] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/19/2020] [Revised: 03/13/2020] [Accepted: 03/23/2020] [Indexed: 12/12/2022]
Abstract
A heterogeneous immunoassay is an efficient biomedical test. It aims to detect the presence of an analyte or to measure its concentration. It has many applications, such as manipulating particles and separating cancer cells from blood. The enhanced performance of immunosensors comes down to capturing more antigens with greater efficiency by antibodies in a short time. In this work, we report an efficient investigation of the effects of alternating current (AC) electrokinetic forces such as AC electroosmosis (ACEO), which arise when the fluid absorbs energy from an applied electric field, on the kinetics of the antigen-antibody binding in a flow system. The force can produce swirling structures in the fluid and, thus, improve the transport of the analyte toward the reaction surface of the immunosensor device. A numerical simulation is adequate for this purpose and may provide valuable information. The convection-diffusion phenomenon is coupled with the first-order Langmuir model. The governing equations are solved using the finite element method (FEM). The impact of AC electroosmosis on the binding reaction kinetics, the fluid flow stream modification, the analyte concentration diffusion, and the detection time of the biosensor under AC electroosmosis are analyzed.
Collapse
Affiliation(s)
- Marwa Selmi
- Department of Radiological Sciences and Medical Imaging, College of Applied Medical Sciences, Majmaah University, Majmaah 11952, Saudi Arabia
- Laboratory of Electronics and Microelectronics, Faculty of Science of Monastir, University of Monastir, Environment Boulevard, Monastir 5019, Tunisia;
- Correspondence: ; Tel.: +966-563447961
| | - Hafedh Belmabrouk
- Laboratory of Electronics and Microelectronics, Faculty of Science of Monastir, University of Monastir, Environment Boulevard, Monastir 5019, Tunisia;
- Department of Physics, College of Sciences at Zulfi, Majmaah University, Majmaah 11952, Saudi Arabia
| |
Collapse
|
16
|
Stoecklein D, Davies M, de Rutte JM, Wu CY, Di Carlo D, Ganapathysubramanian B. FlowSculpt: software for efficient design of inertial flow sculpting devices. LAB ON A CHIP 2019; 19:3277-3291. [PMID: 31482902 DOI: 10.1039/c9lc00658c] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/11/2023]
Abstract
Flow sculpting is a powerful method for passive flow control that uses a sequence of bluff-body structures to engineer the structure of inertially flowing microfluidic streams. A variety of cross-sectional flow shapes can be created through this method, offering a new platform for flow manipulation or material fabrication useful in bioengineering, manufacturing, and chemistry applications. However, the inverse problem in flow sculpting - designing a device that produces a target fluid flow shape - remains challenging due to the complex, diverse, and enormous design space. Solutions to the inverse problem have been constrained to single-material fluid streams that are shaped into top-bottom symmetric shapes due to the bluff-body structures available in current libraries (pillars) that span the height of the channel. In this work, we introduce multi-material design and symmetry-breaking flow deformations enabled by half-height pillars, presented within an extremely fast simulation method for flow sculpting yielding a 34-fold reduction in runtime. The framework is deployed freely as a cross-platform application called "FlowSculpt". We detail its implementation and usage, and discuss the addition of enhanced search operations, which enable users to more easily design flow shapes that replicate their input drawings. With FlowSculpt, the microfluidics community can now quickly design flow shaping microfluidic devices on modest hardware, and easily integrate these complex physics into their research toolkit.
Collapse
Affiliation(s)
- Daniel Stoecklein
- Department of Bioengineering, University of California, Los Angeles, California, USA.
| | - Michael Davies
- Department of Mechanical Engineering, Iowa State University, Ames, Iowa, USA.
| | | | - Chueh-Yu Wu
- Department of Bioengineering, University of California, Los Angeles, California, USA.
| | - Dino Di Carlo
- Department of Bioengineering, University of California, Los Angeles, California, USA.
| | | |
Collapse
|
17
|
Gómez-Pastora J, Karampelas IH, Bringas E, Furlani EP, Ortiz I. Numerical Analysis of Bead Magnetophoresis from Flowing Blood in a Continuous-Flow Microchannel: Implications to the Bead-Fluid Interactions. Sci Rep 2019; 9:7265. [PMID: 31086252 PMCID: PMC6514169 DOI: 10.1038/s41598-019-43827-x] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2018] [Accepted: 04/30/2019] [Indexed: 01/08/2023] Open
Abstract
In this work, we report a numerical flow-focused study of bead magnetophoresis inside a continuous-flow microchannel in order to provide a detailed analysis of bead motion and its effect on fluid flow. The numerical model involves a Lagrangian approach and predicts the bead separation from blood and their collection into a flowing buffer by the application of a magnetic field generated by a permanent magnet. The following scenarios are modelled: (i) one-way coupling wherein momentum is transferred from the fluid to beads, which are treated as point particles, (ii) two-way coupling wherein the beads are treated as point particles and momentum is transferred from the bead to the fluid and vice versa, and (iii) two-way coupling taking into account the effects of bead volume in fluid displacement. The results indicate that although there is little difference in the bead trajectories for the three scenarios, there is significant variation in the flow fields, especially when high magnetic forces are applied on the beads. Therefore, an accurate full flow-focused model that takes into account the effects of the bead motion and volume on the flow field should be solved when high magnetic forces are employed. Nonetheless, when the beads are subjected to medium or low magnetic forces, computationally inexpensive models can be safely employed to model magnetophoresis.
Collapse
Affiliation(s)
- Jenifer Gómez-Pastora
- Department of Chemical and Biomolecular Engineering, ETSIIT, University of Cantabria, Avda. Los Castros s/n, 39005, Santander, Spain
| | | | - Eugenio Bringas
- Department of Chemical and Biomolecular Engineering, ETSIIT, University of Cantabria, Avda. Los Castros s/n, 39005, Santander, Spain
| | - Edward P Furlani
- Department of Chemical and Biological Engineering, University at Buffalo (SUNY), Buffalo, New York, 14260, USA
- Department of Electrical Engineering, University at Buffalo (SUNY), Buffalo, New York, 14260, USA
| | - Inmaculada Ortiz
- Department of Chemical and Biomolecular Engineering, ETSIIT, University of Cantabria, Avda. Los Castros s/n, 39005, Santander, Spain.
| |
Collapse
|
18
|
Fraser LA, Cheung YW, Kinghorn AB, Guo W, Shiu SCC, Jinata C, Liu M, Bhuyan S, Nan L, Shum HC, Tanner JA. Microfluidic Technology for Nucleic Acid Aptamer Evolution and Application. ACTA ACUST UNITED AC 2019; 3:e1900012. [PMID: 32627415 DOI: 10.1002/adbi.201900012] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2019] [Revised: 03/12/2019] [Indexed: 12/18/2022]
Abstract
The intersection of microfluidics and aptamer technologies holds particular promise for rapid progress in a plethora of applications across biomedical science and other areas. Here, the influence of microfluidics on the field of aptamers, from traditional capillary electrophoresis approaches through innovative modern-day approaches using micromagnetic beads and emulsion droplets, is reviewed. Miniaturizing aptamer-based bioassays through microfluidics has the potential to transform diagnostics and embedded biosensing in the coming years.
Collapse
Affiliation(s)
- Lewis A Fraser
- School of Biomedical Sciences, LKS Faculty of Medicine, The University of Hong Kong, Hong Kong (SAR), China
| | - Yee-Wai Cheung
- School of Biomedical Sciences, LKS Faculty of Medicine, The University of Hong Kong, Hong Kong (SAR), China
| | - Andrew B Kinghorn
- School of Biomedical Sciences, LKS Faculty of Medicine, The University of Hong Kong, Hong Kong (SAR), China
| | - Wei Guo
- Department of Mechanical Engineering, Faculty of Engineering, The University of Hong Kong, Hong Kong (SAR), China
| | - Simon Chi-Chin Shiu
- School of Biomedical Sciences, LKS Faculty of Medicine, The University of Hong Kong, Hong Kong (SAR), China
| | - Chandra Jinata
- School of Biomedical Sciences, LKS Faculty of Medicine, The University of Hong Kong, Hong Kong (SAR), China
| | - Mengping Liu
- School of Biomedical Sciences, LKS Faculty of Medicine, The University of Hong Kong, Hong Kong (SAR), China
| | - Soubhagya Bhuyan
- School of Biomedical Sciences, LKS Faculty of Medicine, The University of Hong Kong, Hong Kong (SAR), China
| | - Lang Nan
- Department of Mechanical Engineering, Faculty of Engineering, The University of Hong Kong, Hong Kong (SAR), China
| | - Ho Cheung Shum
- Department of Mechanical Engineering, Faculty of Engineering, The University of Hong Kong, Hong Kong (SAR), China
| | - Julian A Tanner
- School of Biomedical Sciences, LKS Faculty of Medicine, The University of Hong Kong, Hong Kong (SAR), China
| |
Collapse
|
19
|
Kurmashev A, Kwon S, Park JK, Kang JH. Vertically sheathing laminar flow-based immunoassay using simultaneous diffusion-driven immune reactions. RSC Adv 2019; 9:23791-23796. [PMID: 35530621 PMCID: PMC9069447 DOI: 10.1039/c9ra03855h] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2019] [Accepted: 07/24/2019] [Indexed: 11/21/2022] Open
Abstract
Simultaneous infusion of primary and secondary antibodies of different diffusivity into vertical laminar flows enables the improved immune reactions.
Collapse
Affiliation(s)
- Amanzhol Kurmashev
- Department of Biomedical Engineering
- School of Life Sciences
- Ulsan National Institute of Science and Technology (UNIST)
- Ulsan
- Republic of Korea
| | - Seyong Kwon
- Department of Biomedical Engineering
- School of Life Sciences
- Ulsan National Institute of Science and Technology (UNIST)
- Ulsan
- Republic of Korea
| | - Je-Kyun Park
- Department of Bio and Brain Engineering
- Korea Advanced Institute of Science and Technology (KAIST)
- Daejeon
- Republic of Korea
| | - Joo H. Kang
- Department of Biomedical Engineering
- School of Life Sciences
- Ulsan National Institute of Science and Technology (UNIST)
- Ulsan
- Republic of Korea
| |
Collapse
|
20
|
Cheng J, Shao J, Ye Y, Zhao Y, Huang C, Wang L, Li M. Microfluidic Preconcentration Chip with Self-Assembled Chemical Modified Surface for Trace Carbonyl Compounds Detection. SENSORS (BASEL, SWITZERLAND) 2018; 18:E4402. [PMID: 30551558 PMCID: PMC6308564 DOI: 10.3390/s18124402] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/30/2018] [Revised: 12/04/2018] [Accepted: 12/10/2018] [Indexed: 11/22/2022]
Abstract
Carbonyl compounds in water sources are typical characteristic pollutants, which are important indicators in the health risk assessment of water quality. Commonly used analytical chemistry methods face issues such as complex operations, low sensitivity, and long analysis times. Here, we report a silicon microfluidic device based on click chemical surface modification that was engineered to achieve rapid, convenient and efficient capture of trace level carbonyl compounds in liquid solvent. The micro pillar arrays of the chip and microfluidic channels were designed under the basis of finite element (FEM) analysis and fabricated by the microelectromechanical systems (MEMS) technique. The surface of the micropillars was sputtered with precious metal silver and functionalized with the organic substance amino-oxy dodecane thiol (ADT) by self-assembly for capturing trace carbonyl compounds. The detection of ppb level fluorescent carbonyl compounds demonstrates that the strategy proposed in this work shows great potential for rapid water quality testing and for other samples with trace carbonyl compounds.
Collapse
Affiliation(s)
- Jie Cheng
- R&D Center of HealthCare Electronics, Institute of Microelectronics of Chinese Academy of Sciences, Beijing 100029, China.
- School of Future Technology, University of Chinese Academy of Sciences, Beijing 101400, China.
| | - Jianwei Shao
- The State Key Laboratory of Chemical Resource Engineering, Beijing 100029, China.
- College of Materials Science and Engineering, Beijing University of Chemical Technology, Beijing 100029, China.
| | - Yifei Ye
- R&D Center of HealthCare Electronics, Institute of Microelectronics of Chinese Academy of Sciences, Beijing 100029, China.
- School of Future Technology, University of Chinese Academy of Sciences, Beijing 101400, China.
| | - Yang Zhao
- R&D Center of HealthCare Electronics, Institute of Microelectronics of Chinese Academy of Sciences, Beijing 100029, China.
| | - Chengjun Huang
- R&D Center of HealthCare Electronics, Institute of Microelectronics of Chinese Academy of Sciences, Beijing 100029, China.
- School of Future Technology, University of Chinese Academy of Sciences, Beijing 101400, China.
| | - Li Wang
- The State Key Laboratory of Chemical Resource Engineering, Beijing 100029, China.
- College of Materials Science and Engineering, Beijing University of Chemical Technology, Beijing 100029, China.
| | - Mingxiao Li
- R&D Center of HealthCare Electronics, Institute of Microelectronics of Chinese Academy of Sciences, Beijing 100029, China.
| |
Collapse
|
21
|
Sitepu EK, Jones DB, Tang Y, Leterme SC, Heimann K, Zhang W, Raston CL. Continuous flow biodiesel production from wet microalgae using a hybrid thin film microfluidic platform. Chem Commun (Camb) 2018; 54:12085-12088. [PMID: 30298163 DOI: 10.1039/c8cc07610c] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
A novel continuous flow turbo-thin film device (T2FD) has been developed. The microfluidic platform is effective in high yielding production of biodiesel from wet microalgae at room temperature under continuous flow conditions. These findings open the possibility of cost effective production of biodiesel directly from wet microalgae.
Collapse
Affiliation(s)
- Eko K Sitepu
- Centre for Marine Bioproducts Development, Flinders University, South Australia 5042, Australia
| | | | | | | | | | | | | |
Collapse
|
22
|
Gasperino D, Baughman T, Hsieh HV, Bell D, Weigl BH. Improving Lateral Flow Assay Performance Using Computational Modeling. ANNUAL REVIEW OF ANALYTICAL CHEMISTRY (PALO ALTO, CALIF.) 2018; 11:219-244. [PMID: 29595992 DOI: 10.1146/annurev-anchem-061417-125737] [Citation(s) in RCA: 26] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/12/2023]
Abstract
The performance, field utility, and low cost of lateral flow assays (LFAs) have driven a tremendous shift in global health care practices by enabling diagnostic testing in previously unserved settings. This success has motivated the continued improvement of LFAs through increasingly sophisticated materials and reagents. However, our mechanistic understanding of the underlying processes that drive the informed design of these systems has not received commensurate attention. Here, we review the principles underpinning LFAs and the historical evolution of theory to predict their performance. As this theory is integrated into computational models and becomes testable, the criteria for quantifying performance and validating predictive power are critical. The integration of computational design with LFA development offers a promising and coherent framework to choose from an increasing number of novel materials, techniques, and reagents to deliver the low-cost, high-fidelity assays of the future.
Collapse
Affiliation(s)
- David Gasperino
- Intellectual Ventures Laboratory, Bellevue, Washington 98007, USA
| | - Ted Baughman
- Intellectual Ventures Laboratory, Bellevue, Washington 98007, USA
| | - Helen V Hsieh
- Intellectual Ventures Laboratory, Bellevue, Washington 98007, USA
| | - David Bell
- Intellectual Ventures Laboratory, Bellevue, Washington 98007, USA
| | - Bernhard H Weigl
- Intellectual Ventures Laboratory, Bellevue, Washington 98007, USA
- Department of Bioengineering, University of Washington, Seattle, Washington 98195, USA
| |
Collapse
|