1
|
Bezinge L, Shih CJ, Richards DA, deMello AJ. Electrochemical Paper-Based Microfluidics: Harnessing Capillary Flow for Advanced Diagnostics. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2024; 20:e2401148. [PMID: 38801400 DOI: 10.1002/smll.202401148] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/13/2024] [Revised: 04/29/2024] [Indexed: 05/29/2024]
Abstract
Electrochemical paper-based microfluidics has attracted much attention due to the promise of transforming point-of-care diagnostics by facilitating quantitative analysis with low-cost and portable analyzers. Such devices harness capillary flow to transport samples and reagents, enabling bioassays to be executed passively. Despite exciting demonstrations of capillary-driven electrochemical tests, conventional methods for fabricating electrodes on paper impede capillary flow, limit fluidic pathways, and constrain accessible device architectures. This account reviews recent developments in paper-based electroanalytical devices and offers perspective by revisiting key milestones in lateral flow tests and paper-based microfluidics engineering. The study highlights the benefits associated with electrochemical sensing and discusses how the detection modality can be leveraged to unlock novel functionalities. Particular focus is given to electrofluidic platforms that embed electrodes into paper for enhanced biosensing applications. Together, these innovations pave the way for diagnostic technologies that offer portability, quantitative analysis, and seamless integration with digital healthcare, all without compromising the simplicity of commercially available rapid diagnostic tests.
Collapse
Affiliation(s)
- Léonard Bezinge
- Department of Chemistry and Applied Biosciences, Institute for Chemical and Bioengineering, ETH Zürich, Vladimir-Prelog-Weg 1, Zürich, 8093, Switzerland
| | - Chih-Jen Shih
- Department of Chemistry and Applied Biosciences, Institute for Chemical and Bioengineering, ETH Zürich, Vladimir-Prelog-Weg 1, Zürich, 8093, Switzerland
| | - Daniel A Richards
- Department of Chemistry and Applied Biosciences, Institute for Chemical and Bioengineering, ETH Zürich, Vladimir-Prelog-Weg 1, Zürich, 8093, Switzerland
| | - Andrew J deMello
- Department of Chemistry and Applied Biosciences, Institute for Chemical and Bioengineering, ETH Zürich, Vladimir-Prelog-Weg 1, Zürich, 8093, Switzerland
| |
Collapse
|
2
|
Vanmathi S, Awasthi H, Pal A, Goel S. IoT enabled carbon cloth-based 3D printed hydrogen fuel cell integrated with supercapacitor for low-power microelectronic devices. Sci Rep 2024; 14:16953. [PMID: 39043777 PMCID: PMC11266664 DOI: 10.1038/s41598-024-67759-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2024] [Accepted: 07/15/2024] [Indexed: 07/25/2024] Open
Abstract
A Hydrogen fuel cell (HFC) broad range associated with Internet of Things (IoT) technologies that require slightly less and constant electricity made possible by remote climate monitoring connections. Novelty demonstrates a miniature HFC based on carbon cloth electrodes and sealing elements manufactured via 3D printing. Cobalt (II) Oxide (Co3O4)-reduced Graphene Oxide (rGO) and Platinum (Pt) based nanoparticles are coated over carbon cloth to increase the catalytic activity at the anode and cathode. Hydrogen is produced by using an aluminium foil (Al) that is stored in between the filter paper and through capillary action the sodium hydroxide pellets (NaOH) are applied and reacted with Al foil to produce hydrogen. The single HFC device working surface area of 1 × 1 cm2 effectively generates an open circuit voltage (OCV) of 1.3 V, a current density of 1.602 mA/cm2, and a peak power density of 761 mW/cm2. The fuel cell stability performance is monitored for up to 10 h. The power obtained from the HFC is stored in a supercapacitor and used to supply energy to the IoT component. The module includes a built-in sensor that monitors the temperature, pressure, and humidity. The measured data is then transmitted to a smartphone via Bluetooth.
Collapse
Affiliation(s)
- S Vanmathi
- MEMS, Microfluidics and Nanoelectronics (MMNE) Lab, Birla Institute of Technology and Science (BITS) Pilani, Hyderabad Campus, Hyderabad, 500078, India
- Department of Electrical and Electronics Engineering, Birla Institute of Technology and Science (BITS) Pilani, Hyderabad Campus, Hyderabad, 500078, India
| | - Himanshi Awasthi
- MEMS, Microfluidics and Nanoelectronics (MMNE) Lab, Birla Institute of Technology and Science (BITS) Pilani, Hyderabad Campus, Hyderabad, 500078, India
- Department of Electrical and Electronics Engineering, Birla Institute of Technology and Science (BITS) Pilani, Hyderabad Campus, Hyderabad, 500078, India
| | - Abhishesh Pal
- MEMS, Microfluidics and Nanoelectronics (MMNE) Lab, Birla Institute of Technology and Science (BITS) Pilani, Hyderabad Campus, Hyderabad, 500078, India
- Department of Mechanical Engineering, Birla Institute of Technology and Science (BITS) Pilani, Hyderabad Campus, Hyderabad, 500078, India
| | - Sanket Goel
- MEMS, Microfluidics and Nanoelectronics (MMNE) Lab, Birla Institute of Technology and Science (BITS) Pilani, Hyderabad Campus, Hyderabad, 500078, India.
- Department of Electrical and Electronics Engineering, Birla Institute of Technology and Science (BITS) Pilani, Hyderabad Campus, Hyderabad, 500078, India.
| |
Collapse
|
3
|
Ganesh PS, Elugoke SE, Lee SH, Kim SY, Ebenso EE. Smart and emerging point of care electrochemical sensors based on nanomaterials for SARS-CoV-2 virus detection: Towards designing a future rapid diagnostic tool. CHEMOSPHERE 2024; 352:141269. [PMID: 38307334 DOI: 10.1016/j.chemosphere.2024.141269] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/20/2023] [Revised: 01/08/2024] [Accepted: 01/18/2024] [Indexed: 02/04/2024]
Abstract
In the recent years, researchers from all over the world have become interested in the fabrication of advanced and innovative electrochemical and/or biosensors for respiratory virus detection with the use of nanotechnology. These fabricated sensors demonstrated a number of benefits, including precision, affordability, accessibility, and miniaturization which makes them a promising test method for point-of-care (PoC) screening for SARS-CoV-2 viral infection. In order to comprehend the principles of electrochemical sensing and the role of various types of sensing interfaces, we comprehensively explored the underlying principles of electroanalytical methods and terminologies related to it in this review. In addition, it is addressed how to fabricate electrochemical sensing devices incorporating nanomaterials as graphene, metal/metal oxides, metal organic frameworks (MOFs), MXenes, quantum dots, and polymers. We took an effort to carefully compile current developments, advantages, drawbacks, possible solutions in nanomaterials based electrochemical sensors.
Collapse
Affiliation(s)
- Pattan Siddappa Ganesh
- Interaction Laboratory, Advanced Technology Research Center, Future Convergence Engineering, Korea University of Technology and Education, Cheonan-si, Chungcheongnam-do, 330-708, Republic of Korea.
| | - Saheed Eluwale Elugoke
- Centre for Material Science, College of Science, Engineering and Technology, University of South Africa, Johannesburg 1709, South Africa; Institute for Nanotechnology and Water Sustainability (iNanoWS), College of Science, Engineering and Technology, University of South Africa, Johannesburg 1709, South Africa
| | - Seok-Han Lee
- Interaction Laboratory, Advanced Technology Research Center, Future Convergence Engineering, Korea University of Technology and Education, Cheonan-si, Chungcheongnam-do, 330-708, Republic of Korea
| | - Sang-Youn Kim
- Interaction Laboratory, Advanced Technology Research Center, Future Convergence Engineering, Korea University of Technology and Education, Cheonan-si, Chungcheongnam-do, 330-708, Republic of Korea.
| | - Eno E Ebenso
- Centre for Material Science, College of Science, Engineering and Technology, University of South Africa, Johannesburg 1709, South Africa; Institute for Nanotechnology and Water Sustainability (iNanoWS), College of Science, Engineering and Technology, University of South Africa, Johannesburg 1709, South Africa.
| |
Collapse
|
4
|
Barraza DE, Nanni PI, Bracamonte ME, Chaile RE, Goy CB, Acuña L, Marco JD, Madrid RE. Simple and promising paper-based electrochemical platform for serological detection of American tegumentary leishmaniasis. Mem Inst Oswaldo Cruz 2024; 119:e230149. [PMID: 38359306 PMCID: PMC10868376 DOI: 10.1590/0074-02760230149] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2023] [Accepted: 01/24/2024] [Indexed: 02/17/2024] Open
Abstract
BACKGROUND American tegumentary leishmaniasis (ATL) is an endemic neglected tropical disease (NTD), its conventional treatment is toxic, slow, and invasive. Rapid diagnosis is crucial for the clinical management of suspected patients, so the development and use of low-cost, miniaturised and portable devices could be the key. OBJECTIVES This work aimed to develop a simple paper-based electrochemical platform for the serological detection of ATL. METHODS Platform was fabricated in Whatman N°1 paper, contains a hydrophobic zone generated by wax printing, two pencil graphite electrodes, and uses specific crude extracts (CA) antigens for ATL immuno-determination. The platform performance was analysed by measuring the relative impedance change for different antigen-antibody combinations. Then, 10 serum human samples previously diagnosed by the gold standard (five positive ATL cases and five non-ATL cases) were evaluated. FINDINGS The platform presented a linear response for the charge transfer resistance (ΔRct) and the interface reactance (ΔXc). Also, optimal working conditions were established (1/60 serum dilution and 180 µg/mL CA concentration). Then, the platform permits to distinguish between ATL and non-ATL (p < 0.05) human serum samples. MAIN CONCLUSIONS Our platform could allow the diagnosis, management, and monitoring of leishmaniasis while being an extremely simple and environmentally friendly technology.
Collapse
Affiliation(s)
- Daniela E Barraza
- Consejo Nacional de Investigaciones Científicas y Técnicas, Universidad Nacional de Tucumán, Facultad de Ciencias Exactas y Tecnología, Instituto Superior de Investigaciones Biológicas, Laboratorio de Medios e Interfases, Tucumán, Argentina
| | - Paula I Nanni
- Consejo Nacional de Investigaciones Científicas y Técnicas, Universidad Nacional de Tucumán, Facultad de Ciencias Exactas y Tecnología, Instituto Superior de Investigaciones Biológicas, Laboratorio de Medios e Interfases, Tucumán, Argentina
| | - María E Bracamonte
- Consejo Nacional de Investigaciones Científicas y Técnicas, Universidad Nacional de Salta, Facultad de Ciencias de la Salud, Instituto de Patología Experimental, Salta, Argentina
| | - Roberto E Chaile
- Consejo Nacional de Investigaciones Científicas y Técnicas, Universidad Nacional de Tucumán, Facultad de Ciencias Exactas y Tecnología, Instituto Superior de Investigaciones Biológicas, Laboratorio de Medios e Interfases, Tucumán, Argentina
| | - Carla B Goy
- Consejo Nacional de Investigaciones Científicas y Técnicas, Universidad Nacional de Tucumán, Facultad de Ciencias Exactas y Tecnología, Instituto Superior de Investigaciones Biológicas, Laboratorio de Medios e Interfases, Tucumán, Argentina
| | - Leonardo Acuña
- Consejo Nacional de Investigaciones Científicas y Técnicas, Universidad Nacional de Salta, Facultad de Ciencias de la Salud, Instituto de Patología Experimental, Salta, Argentina
| | - Jorge D Marco
- Consejo Nacional de Investigaciones Científicas y Técnicas, Universidad Nacional de Salta, Facultad de Ciencias de la Salud, Instituto de Patología Experimental, Salta, Argentina
| | - Rossana E Madrid
- Consejo Nacional de Investigaciones Científicas y Técnicas, Universidad Nacional de Tucumán, Facultad de Ciencias Exactas y Tecnología, Instituto Superior de Investigaciones Biológicas, Laboratorio de Medios e Interfases, Tucumán, Argentina
| |
Collapse
|
5
|
Min J, Jung Y, Ahn J, Lee JG, Lee J, Ko SH. Recent Advances in Biodegradable Green Electronic Materials and Sensor Applications. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2023; 35:e2211273. [PMID: 36934454 DOI: 10.1002/adma.202211273] [Citation(s) in RCA: 16] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/02/2022] [Revised: 03/16/2023] [Indexed: 06/18/2023]
Abstract
As environmental issues have become the dominant agenda worldwide, the necessity for more environmentally friendly electronics has recently emerged. Accordingly, biodegradable or nature-derived materials for green electronics have attracted increased interest. Initially, metal-green hybrid electronics are extensively studied. Although these materials are partially biodegradable, they have high utility owing to their metallic components. Subsequently, carbon-framed materials (such as graphite, cylindrical carbon nanomaterials, graphene, graphene oxide, laser-induced graphene) have been investigated. This has led to the adoption of various strategies for carbon-based materials, such as blending them with biodegradable materials. Moreover, various conductive polymers have been developed and researchers have studied their potential use in green electronics. Researchers have attempted to fabricate conductive polymer composites with high biodegradability by shortening the polymer chains. Furthermore, various physical, chemical, and biological sensors that are essential to modern society have been studied using biodegradable compounds. These recent advances in green electronics have paved the way toward their application in real life, providing a brighter future for society.
Collapse
Affiliation(s)
- JinKi Min
- Applied Nano and Thermal Science Lab, Department of Mechanical Engineering, Seoul National University, 1 Gwanak-ro, Gwanak-gu, Seoul, 08826, Republic of Korea
| | - Yeongju Jung
- Applied Nano and Thermal Science Lab, Department of Mechanical Engineering, Seoul National University, 1 Gwanak-ro, Gwanak-gu, Seoul, 08826, Republic of Korea
| | - Jiyong Ahn
- Applied Nano and Thermal Science Lab, Department of Mechanical Engineering, Seoul National University, 1 Gwanak-ro, Gwanak-gu, Seoul, 08826, Republic of Korea
| | - Jae Gun Lee
- Applied Nano and Thermal Science Lab, Department of Mechanical Engineering, Seoul National University, 1 Gwanak-ro, Gwanak-gu, Seoul, 08826, Republic of Korea
| | - Jinwoo Lee
- Department of Mechanical, Robotics, and Energy Engineering, Dongguk University, 30 Pildong-ro 1-gil, Jung-gu, Seoul, 04620, Republic of Korea
| | - Seung Hwan Ko
- Applied Nano and Thermal Science Lab, Department of Mechanical Engineering, Seoul National University, 1 Gwanak-ro, Gwanak-gu, Seoul, 08826, Republic of Korea
- Institute of Engineering Research/Institute of Advanced Machinery and Design (SNU-IAMD), Seoul National University, Gwanak-ro, Gwanak-gu, Seoul, 08826, Republic of Korea
| |
Collapse
|
6
|
Mohan JM, Dudala S, Amreen K, Javed A, Dubey SK, Goel S. Microfluidic Device Integrated With PDMS Microchannel and Unmodified ITO Glass Electrodes for Highly Sensitive, Specific, and Point-of-Care Detection of Copper and Mercury. IEEE Trans Nanobioscience 2023; 22:881-888. [PMID: 37022373 DOI: 10.1109/tnb.2023.3241827] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
This work delves upon developing a two-layer plasma-bonded microfluidic device with a microchannel layer and electrodes for electroanalytical detection of heavy metal ions. The three-electrode system was realized on an ITO-glass slide by suitably etching the ITO layer with the help of CO2 laser. The microchannel layer was fabricated using a PDMS soft-lithography method wherein the mold created by maskless lithography. The optimized dimensions opted to develop a microfluidic device with length of 20 mm, width of 0.5 mm and gap of 1 mm. The device, with bare unmodified ITO electrodes, was tested to detect Cu and Hg by a portable potentiostat connected with a smartphone. The analytes were introduced in the microfluidic device with a peristaltic pump at an optimal flow rate of [Formula: see text]/min. The device exhibited sensitive electro-catalytic sensing of both the metals by achieving an oxidation peak at -0.4 V and 0.1 V for Cu and Hg respectively. Furthermore, square wave voltammetry (SWV) approach was used to analyze the scan rate effect and concentration effect. The device also used to simultaneously detect both the analytes. During simultaneous sensing of Hg and Cu, the linear range was observed between [Formula: see text] to [Formula: see text], the limit of detection (LOD) was found to be [Formula: see text] and [Formula: see text] for Cu and Hg respectively. Further, no interference with other co-existing metal ions was found manifesting the specificity of the device to Cu and Hg. Finally, the device was successfully tested with real samples like tap water, lake water, and serum with remarkable recovery percentages. Such portable devices pave way for detecting various heavy metal ions in a point-of-care environment. The developed device can also be used for detection of other heavy metals like cadmium, lead, zinc etc., by modifying the working electrode with the various nanocomposites.
Collapse
|
7
|
Faustino LC, Cunha JPC, Cantanhêde W, Kubota LT, Gerôncio ETS. 3D-printed holder for drawing highly reproducible pencil-on-paper electrochemical devices. Mikrochim Acta 2023; 190:338. [PMID: 37522993 DOI: 10.1007/s00604-023-05920-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2023] [Accepted: 07/15/2023] [Indexed: 08/01/2023]
Abstract
Pencil drawing is one of the simplest and most cost-effective ways of fabricating miniaturized electrodes on a paper substrate. However, it is limited by the lack of reproducibility regarding the electrode drawing process. A 3D-printed pencil holder (3DPH) is proposed here for simple, reproducible, and low-cost hand-drawn fabrication of paper-based electrochemical devices. 3DPH was designed to keep pressure and angulation of the graphite mine constant on the paper substrate using a micromechanical pencil regardless of the user/operator. This approach significantly improved the reproducibility and cost of making reliable pencil-drawn electrodes. The results showed high reproducibility and accuracy of the 3DPH-assisted electrodes prepared by 4 different operators in terms of sheet resistance and electrochemical behavior. Cyclic voltammetric (CV) curves in the presence of [Fe(CN)6]3-/4- redox probe showed only 3.9% variation for the anodic peak currents of different electrodes prepared by different operators when compared with electrodes prepared without the 3D-printed support. SEM analyses revealed a more uniform graphite deposition/design of the electrodes prepared with 3DPH, which corroborates the results obtained by CV. As a proof of concept, 3DPH-assisted pencil-drawn graphite electrodes were employed for dopamine detection in synthetic saliva, showing a proportional increase in anodic peak current at 0.12 V vs. carbon pRE with increasing dopamine (DA) concentration, with a detection limit of 0.39μmol L-1. Moreover recovery was in the range 93-104% of DA (4-7% RSD) in synthetic saliva for three different concentrations, demonstrating the reliability of the approach. Finally, we believe this approach can make pencil-drawn technology more robust, accessible, reliable, and inexpensive for real on-site applications, especially in hard-to-reach locations or research centers with little investment.
Collapse
Affiliation(s)
- Lucas C Faustino
- Department of Chemistry, Federal University of Piauí - UFPI, Teresina, PI, 64049-550, Brazil
| | - João P C Cunha
- Department of Chemistry, State University of Piauí - UESPI, Teresina, PI, 64002-150, Brazil
| | - Welter Cantanhêde
- Department of Chemistry, Federal University of Piauí - UFPI, Teresina, PI, 64049-550, Brazil
| | - Lauro T Kubota
- Department of Analytical Chemistry, Institute of Chemistry, State University of Campinas - UNICAMP, Campinas, SP, 13084-971, Brazil
| | - Everson T S Gerôncio
- Department of Chemistry, Federal University of Piauí - UFPI, Teresina, PI, 64049-550, Brazil.
- Department of Chemistry, State University of Piauí - UESPI, Teresina, PI, 64002-150, Brazil.
| |
Collapse
|
8
|
Ibrahim OA, Navarro-Segarra M, Sadeghi P, Sabaté N, Esquivel JP, Kjeang E. Microfluidics for Electrochemical Energy Conversion. Chem Rev 2022; 122:7236-7266. [PMID: 34995463 DOI: 10.1021/acs.chemrev.1c00499] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
Electrochemical energy conversion is an important supplement for storage and on-demand use of renewable energy. In this regard, microfluidics offers prospects to raise the efficiency and rate of electrochemical energy conversion through enhanced mass transport, flexible cell design, and ability to eliminate the physical ion-exchange membrane, an essential yet costly element in conventional electrochemical cells. Since the 2002 invention of the microfluidic fuel cell, the research field of microfluidics for electrochemical energy conversion has expanded into a great variety of cell designs, fabrication techniques, and device functions with a wide range of utility and applications. The present review aims to comprehensively synthesize the best practices in this field over the past 20 years. The underlying fundamentals and research methods are first summarized, followed by a complete assessment of all research contributions wherein microfluidics was proactively utilized to facilitate energy conversion in conjunction with electrochemical cells, such as fuel cells, flow batteries, electrolysis cells, hybrid cells, and photoelectrochemical cells. Moreover, emerging technologies and analytical tools enabled by microfluidics are also discussed. Lastly, opportunities for future research directions and technology advances are proposed.
Collapse
Affiliation(s)
- Omar A Ibrahim
- Fuel Cell Research Laboratory, School of Mechatronic Systems Engineering, Simon Fraser University, V3T 0A3 Surrey, British Columbia Canada.,Fuelium S.L., Edifici Eureka, Av. Can Domènech S/N, 08193 Bellaterra, Barcelona Spain
| | - Marina Navarro-Segarra
- Instituto de Microelectrónica de Barcelona, IMB-CNM (CSIC), C/dels Til·lers sn, Campus UAB, 08193 Bellaterra Barcelona Spain
| | - Pardis Sadeghi
- Fuel Cell Research Laboratory, School of Mechatronic Systems Engineering, Simon Fraser University, V3T 0A3 Surrey, British Columbia Canada
| | - Neus Sabaté
- Instituto de Microelectrónica de Barcelona, IMB-CNM (CSIC), C/dels Til·lers sn, Campus UAB, 08193 Bellaterra Barcelona Spain.,Catalan Institution for Research and Advanced Studies (ICREA), Passeig Lluís Companys 23, 08010 Barcelona, Spain
| | - Juan Pablo Esquivel
- Instituto de Microelectrónica de Barcelona, IMB-CNM (CSIC), C/dels Til·lers sn, Campus UAB, 08193 Bellaterra Barcelona Spain.,BCMaterials, Basque Centre for Materials, Applications and Nanostructures, UPV/EHU Science Park, 48940 Leioa, Spain.,IKERBASQUE, Basque Foundation for Science, 48009 Bilbao, Spain
| | - Erik Kjeang
- Fuel Cell Research Laboratory, School of Mechatronic Systems Engineering, Simon Fraser University, V3T 0A3 Surrey, British Columbia Canada
| |
Collapse
|