1
|
Cai Y, Li Z, Sun C, Zhao X, Wu S, Huang G, Tang S, Dai P, Wei X, You H. A centrifugal-driven spiral microchannel microfiltration chip for emulsion and deformable particle sorting. LAB ON A CHIP 2024; 24:3738-3751. [PMID: 38978468 DOI: 10.1039/d4lc00260a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 07/10/2024]
Abstract
Droplet sorting and enrichment, as a prominent field within microfluidic technology, represent a pivotal stage in the manipulation of droplets and particles. In recent times, droplet sorting methods based on lab-on-disk (LOD) have garnered significant interest among researchers for their inherent merits, including high throughput, ease of operation, seamless device integration, and independence from supplementary driving forces. This study introduces a centrifugal force-driven microfluidic chip comprising spiral microchannels. The chip incorporates microhole arrays along the sidewall of the spiral channels, enabling size-based sorting and enrichment of microdroplets under the influence of multiple forces. Firstly, a comparative analysis was performed to assess the influence of the separation port structure and rotational speed on efficiency, and a mechanical modeling approach was employed to conduct kinetic analyses of droplet behavior during instantaneous separation. Those findings demonstrated a good agreement with the experimental results at ω < 100 rpm. Subsequently, sorting experiments on homogeneous droplets indicated that repetitive sorting could increase the recovery ratios, RT(α), of high-concentration droplets (20.7%) from 35.3% to over 80%. We also conducted a sorting experiment on three-component homogeneous-phase emulsions using a serially connected chip array, and the sorting throughput was 0.58 mL min-1. As a result, the RT(α) for 60 and 160 μm droplets were 99.4% and 88.9%, respectively. Lastly, we conducted elution experiments and dual-sample sorting on a single chip, and the fluorescence results demonstrated that this study provided an efficient and non-cross-contaminating sorting method for non-homogenous phase multi-sample microreactor units.
Collapse
Affiliation(s)
- Yongchao Cai
- School of Mechanical Engineering, Guangxi University, Nanning, Guangxi, China.
| | - Zekun Li
- School of Mechanical Engineering, Guangxi University, Nanning, Guangxi, China.
| | - Cuimin Sun
- School of Computer, Electronics and Information, Guangxi University, Nanning, Guangxi, China.
| | - Xuan Zhao
- School of Mechanical Engineering, Guangxi University, Nanning, Guangxi, China.
| | - Shixiong Wu
- School of Mechanical Engineering, Guangxi University, Nanning, Guangxi, China.
| | - Guangyong Huang
- School of Mechanical and Automotive Engineering, Guangxi University of Science and Technology, Liuzhou, Guangxi, China
| | - Shengchang Tang
- School of Mechanical Engineering, Guangxi University, Nanning, Guangxi, China.
| | - Peng Dai
- School of Mechanical Engineering, Guangxi University, Nanning, Guangxi, China.
| | - Xiangfu Wei
- School of Mechanical Engineering, Guangxi University, Nanning, Guangxi, China.
| | - Hui You
- School of Mechanical Engineering, Guangxi University, Nanning, Guangxi, China.
| |
Collapse
|
2
|
Wei YJ, Wei X, Zhang X, Wu CX, Cai JY, Chen ML, Wang JH. A hydrodynamic-based dual-function microfluidic chip for high throughput discriminating tumor cells. Talanta 2024; 273:125884. [PMID: 38508128 DOI: 10.1016/j.talanta.2024.125884] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2023] [Revised: 02/26/2024] [Accepted: 03/06/2024] [Indexed: 03/22/2024]
Abstract
A hydrodynamic-based microfluidic chip consisted of two function units that could not only separate tumor cells (TCs) from whole blood but also remove residual blood cells was designed. The separation of TCs was achieved by a straight contraction-expansion array (CEA) microchannel on the front end of the chip. The addition of contractive structure brought a micro-vortex like Dean vortex that promoted cell focusing in the channel, while when cells entered the dilated region, the wall-induced lift force generated by the channel wall gave cells a push away from the wall. As the wall-induced lift force is proportional to the third power of the cell diameter, TCs with larger diameter will have a larger lateral migration under the wall-induced lift force, realizing the separation of TCs from blood sample. Fluorescent particles with diameters of 19.3 μm and 4.5 μm were used to simulate TCs and red blood cells, respectively, to verify the separation capacity of the proposed CEA microchannel for particles with different diameter. And a separation efficiency 98.7% for 19.3 μm particles and a removal rate 96.2% for 4.5 μm particles was observed at sample flow rate of 10 μL min-1 and sheath flow rate of 190 μL min-1. In addition, a separation efficiency about 96.1% for MCF-7 cells (stained with DiI) and removal rates of 96.2% for red blood cells (RBCs) and 98.7% for white blood cells (WBCs) were also obtained under the same condition. However, on account of the large number of blood cells in the blood, there will be a large number of blood cells remained in the isolated TCs, so a purification unit based on hydrodynamic filtration (HDF) was added after the separation microchannel. The purification channel is a size-dictated cell filter that can remove residual blood cells but retain TCs, thus achieving the purification of TCs. Combined the CEA microchannel and the purifier, the microchip facilitates sorting of MCF-7 cells from whole blood with a separation rate about 95.3% and a removal rate over 99.99% for blood cells at a sample flow rate of 10 μL min-1, sheath flow rate of 190 μL min-1 and washing flow rate of 63 μL min-1.
Collapse
Affiliation(s)
- Yu-Jia Wei
- Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Box 332, Shenyang, 110819, China
| | - Xing Wei
- Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Box 332, Shenyang, 110819, China
| | - Xuan Zhang
- Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Box 332, Shenyang, 110819, China
| | - Cheng-Xing Wu
- Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Box 332, Shenyang, 110819, China
| | - Ji-Ying Cai
- Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Box 332, Shenyang, 110819, China
| | - Ming-Li Chen
- Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Box 332, Shenyang, 110819, China.
| | - Jian-Hua Wang
- Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Box 332, Shenyang, 110819, China.
| |
Collapse
|
3
|
Hayashi A, Hemmi R, Saito Y, Utoh R, Taniguchi T, Yamada M. High-Density Microporous Drainage-Integrating Sheath Flow Generator for Streamlining Microfluidic Cell Sorting Systems. Anal Chem 2024; 96:6764-6773. [PMID: 38619911 DOI: 10.1021/acs.analchem.4c00485] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/17/2024]
Abstract
Tremendous efforts have been made to develop practical and efficient microfluidic cell and particle sorting systems; however, there are technological limitations in terms of system complexity and low operability. Here, we propose a sheath flow generator that can dramatically simplify operational procedures and enhance the usability of microfluidic cell sorters. The device utilizes an embedded polydimethylsiloxane (PDMS) sponge with interconnected micropores, which is in direct contact with microchannels and seamlessly integrated into the microfluidic platform. The high-density micropores on the sponge surface facilitated fluid drainage, and the drained fluid was used as the sheath flow for downstream cell sorting processes. To fabricate the integrated device, a new process for sponge-embedded substrates was developed through the accumulation, incorporation, and dissolution of PMMA microparticles as sacrificial porogens. The effects of the microchannel geometry and flow velocity on the sheath flow generation were investigated. Furthermore, an asymmetric lattice-shaped microchannel network for cell/particle sorting was connected to the sheath flow generator in series, and the sorting performances of model particles, blood cells, and spiked tumor cells were investigated. The sheath flow generation technique developed in this study is expected to streamline conventional microfluidic cell-sorting systems as it dramatically improves versatility and operability.
Collapse
Affiliation(s)
- Ayumi Hayashi
- Department of Applied Chemistry and Biotechnology, Graduate School of Engineering, Chiba University, 1-33 Yayoi-cho, Inage-ku, Chiba 263-8522, Japan
| | - Runa Hemmi
- Department of Applied Chemistry and Biotechnology, Graduate School of Engineering, Chiba University, 1-33 Yayoi-cho, Inage-ku, Chiba 263-8522, Japan
| | - Yuhei Saito
- Department of Applied Chemistry and Biotechnology, Graduate School of Engineering, Chiba University, 1-33 Yayoi-cho, Inage-ku, Chiba 263-8522, Japan
| | - Rie Utoh
- Department of Applied Chemistry and Biotechnology, Graduate School of Engineering, Chiba University, 1-33 Yayoi-cho, Inage-ku, Chiba 263-8522, Japan
| | - Tatsuo Taniguchi
- Department of Applied Chemistry and Biotechnology, Graduate School of Engineering, Chiba University, 1-33 Yayoi-cho, Inage-ku, Chiba 263-8522, Japan
| | - Masumi Yamada
- Department of Applied Chemistry and Biotechnology, Graduate School of Engineering, Chiba University, 1-33 Yayoi-cho, Inage-ku, Chiba 263-8522, Japan
| |
Collapse
|
4
|
Storti F, Bonfadini S, Mangini M, De Luca AC, Criante L. High throughput clogging free microfluidic particle filter by femtosecond laser micromachining. Electrophoresis 2024. [PMID: 38687174 DOI: 10.1002/elps.202300253] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2023] [Revised: 04/13/2024] [Accepted: 04/16/2024] [Indexed: 05/02/2024]
Abstract
In recent decades, driven by the needs of industry and medicine, researchers have been investigating how to remove carefully from the main flow microscopic particles or clusters of them. Among all the approaches proposed, crossflow filtration is one of the most attractive as it provides a non-destructive, label-free and in-flow sorting method. In general, the separation performance shows capture and separation efficiencies ranging from 70% up to 100%. However, the maximum flow rate achievable (µL/min) is still orders of magnitude away from those suitable for clinical or industrial applications mainly due to the low stiffness of the materials typically used. In this work, we propose an innovative hydrodynamic-crossflow hybrid filter geometry, buried in a fused silica substrate by means of the femtosecond laser irradiation followed by chemical etching technique. The material high stiffness combined with the accuracy of our manufacturing technique allows the 3D fabrication of non-deformable channels with higher aspect ratio posts, while keeping the overall device dimensions compact. The filter performance has been validated through experiments with both Newtonian (water-based solution of microbeads) and non-Newtonian fluids (blood), achieving separation efficiencies of up to 94% and large particles recovery rates of 100%, even at very high flow rates (mL/h).
Collapse
Affiliation(s)
- Filippo Storti
- Center for Nano Science and Technology, Istituto Italiano di Tecnologia, Milano, Italy
- Dipartimento di Fisica, Politecnico di Milano, Milano, Italy
| | - Silvio Bonfadini
- Center for Nano Science and Technology, Istituto Italiano di Tecnologia, Milano, Italy
| | - Maria Mangini
- Institute of Experimental Endocrinology and Oncology "G. Salvatore", IEOS-Second Unit, National Research Council, CNR, Napoli, Italy
| | - Anna Chiara De Luca
- Institute of Experimental Endocrinology and Oncology "G. Salvatore", IEOS-Second Unit, National Research Council, CNR, Napoli, Italy
| | - Luigino Criante
- Center for Nano Science and Technology, Istituto Italiano di Tecnologia, Milano, Italy
| |
Collapse
|
5
|
Zhang X, Wei X, Wu CX, Men X, Wang J, Bai JJ, Sun XY, Wang Y, Yang T, Lim CT, Chen ML, Wang JH. Multiplex Profiling of Biomarker and Drug Uptake in Single Cells Using Microfluidic Flow Cytometry and Mass Spectrometry. ACS NANO 2024; 18:6612-6622. [PMID: 38359901 PMCID: PMC10906074 DOI: 10.1021/acsnano.3c12803] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/19/2023] [Revised: 01/29/2024] [Accepted: 01/31/2024] [Indexed: 02/17/2024]
Abstract
To perform multiplex profiling of single cells and eliminate the risk of potential sample loss caused by centrifugation, we developed a microfluidic flow cytometry and mass spectrometry system (μCytoMS) to evaluate the drug uptake and induced protein expression at the single cell level. It involves a microfluidic chip for the alignment and purification of single cells followed by detection with laser-induced fluorescence (LIF) and inductively coupled plasma mass spectrometry (ICP-MS). Biofunctionalized nanoprobes (BioNPs), conjugating ∼3000 6-FAM-Sgc8 aptamers on a single gold nanoparticle (AuNP) (Kd = 0.23 nM), were engineered to selectively bind with protein tyrosine kinase 7 (PTK7) on target cells. PTK7 expression induced by oxaliplatin (OXA) uptake was assayed with LIF, while ICP-MS measurement of 195Pt revealed OXA uptake of the drug in individual cells, which provided further in-depth information about the drug in relation to PTK7 expression. At an ultralow flow of ∼0.043 dyn/cm2 (20 μL/min), the chip facilitates the extremely fast focusing of BioNPs labeled single cells without the need for centrifugal purification. It ensures multiplex profiling of single cells at a throughput speed of 500 cells/min as compared to 40 cells/min in previous studies. Using a machine learning algorithm to initially profile drug uptake and marker expression in tumor cell lines, μCytoMS was able to perform in situ profiling of the PTK7 response to the OXA at single-cell resolution for tests done on clinical samples from 10 breast cancer patients. It offers great potential for multiplex single-cell phenotypic analysis and clinical diagnosis.
Collapse
Affiliation(s)
- Xuan Zhang
- Research
Center for Analytical Sciences, Department of Chemistry, College of
Sciences, Northeastern University, Box 332, Shenyang 110819, China
- Institute
for Health Innovation and Technology, National
University of Singapore, 117599, Singapore
- Academy
of Medical Science, Shanxi Medical University, Taiyuan 030001, China
| | - Xing Wei
- Research
Center for Analytical Sciences, Department of Chemistry, College of
Sciences, Northeastern University, Box 332, Shenyang 110819, China
| | - Cheng-Xin Wu
- Research
Center for Analytical Sciences, Department of Chemistry, College of
Sciences, Northeastern University, Box 332, Shenyang 110819, China
| | - Xue Men
- Research
Center for Analytical Sciences, Department of Chemistry, College of
Sciences, Northeastern University, Box 332, Shenyang 110819, China
| | - Jiao Wang
- Research
Center for Analytical Sciences, Department of Chemistry, College of
Sciences, Northeastern University, Box 332, Shenyang 110819, China
| | - Jun-Jie Bai
- Research
Center for Analytical Sciences, Department of Chemistry, College of
Sciences, Northeastern University, Box 332, Shenyang 110819, China
| | - Xiao-Yan Sun
- Research
Center for Analytical Sciences, Department of Chemistry, College of
Sciences, Northeastern University, Box 332, Shenyang 110819, China
| | - Yu Wang
- Research
Center for Analytical Sciences, Department of Chemistry, College of
Sciences, Northeastern University, Box 332, Shenyang 110819, China
| | - Ting Yang
- Research
Center for Analytical Sciences, Department of Chemistry, College of
Sciences, Northeastern University, Box 332, Shenyang 110819, China
| | - Chwee Teck Lim
- Institute
for Health Innovation and Technology, National
University of Singapore, 117599, Singapore
- Department
of Biomedical Engineering, National University
of Singapore, 117576, Singapore
| | - Ming-Li Chen
- Research
Center for Analytical Sciences, Department of Chemistry, College of
Sciences, Northeastern University, Box 332, Shenyang 110819, China
| | - Jian-Hua Wang
- Research
Center for Analytical Sciences, Department of Chemistry, College of
Sciences, Northeastern University, Box 332, Shenyang 110819, China
| |
Collapse
|
6
|
Feng X, Qi F, Wang H, Li W, Gan Y, Qi C, Lin Z, Chen L, Wang P, Hu Z, Miao Y. Sorting Technology for Mesenchymal Stem Cells from a Single Tissue Source. Stem Cell Rev Rep 2024; 20:524-537. [PMID: 38112926 DOI: 10.1007/s12015-023-10635-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/23/2023] [Indexed: 12/21/2023]
Abstract
Mesenchymal stem cells (MSCs) are adult stem cells that can be obtained, enriched and proliferated in vitro. They owned enormous potential in fields like regenerative medicine, tissue engineering and immunomodulation. However, though isolated from the same origin, MSCs are still essentially heterogeneous cell populations with different phenotypes and functions. This heterogeneity of MSCs significantly affects their therapeutic efficacy and brings obstacles to scientific research. Thus, reliable sorting technology which can isolate or purify MSC subpopulations with various potential and differentiation pathways is urgently needed. This review summarized principles, application status and clinical implications for these sorting methods, aiming at improving the understanding of MSC heterogeneity as well as providing fresh perspectives for subsequent clinical applications.
Collapse
Affiliation(s)
- Xinyi Feng
- The First Clinical School of Southern Medical University, Guangzhou, China
| | - Fangfang Qi
- Department of Plastic and Aesthetic Surgery, Nanfang Hospital of Southern Medical University, Guangzhou, China
| | - Hailin Wang
- Department of Plastic and Aesthetic Surgery, Nanfang Hospital of Southern Medical University, Guangzhou, China
| | - Wenzhen Li
- Department of Plastic and Aesthetic Surgery, Nanfang Hospital of Southern Medical University, Guangzhou, China
| | - Yuyang Gan
- Department of Plastic and Aesthetic Surgery, Nanfang Hospital of Southern Medical University, Guangzhou, China
| | - Caiyu Qi
- The First Clinical School of Southern Medical University, Guangzhou, China
| | - Zhen Lin
- Department of Plastic and Aesthetic Surgery, Nanfang Hospital of Southern Medical University, Guangzhou, China
| | - Lu Chen
- Department of Plastic and Aesthetic Surgery, Nanfang Hospital of Southern Medical University, Guangzhou, China
| | - Piao Wang
- Department of Plastic and Aesthetic Surgery, Nanfang Hospital of Southern Medical University, Guangzhou, China
| | - Zhiqi Hu
- Department of Plastic and Aesthetic Surgery, Nanfang Hospital of Southern Medical University, Guangzhou, China.
| | - Yong Miao
- Department of Plastic and Aesthetic Surgery, Nanfang Hospital of Southern Medical University, Guangzhou, China.
| |
Collapse
|
7
|
Zhang J, Tang H, Zhang J, Zhang Z. Mesoscopic simulation of multi-scheme particle separation in deterministic lateral displacement devices using two-piece hybrid pillars. J Chromatogr A 2023; 1711:464434. [PMID: 37837711 DOI: 10.1016/j.chroma.2023.464434] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2023] [Revised: 09/16/2023] [Accepted: 10/05/2023] [Indexed: 10/16/2023]
Abstract
Pillar shape exploration in deterministic lateral displacement (DLD) technique holds great promise for developing high-performance microfluidic devices with versatile sorting schemes. A recent innovative design using filter-like micropillars was proposed to improve cell separation, but its significance might be greatly underestimated due to an inaccurate understanding of the underlying mechanism. In this study, we employ mesoscopic hydrodynamic simulations to explore the movement and separation of rigid spherical particles in DLD arrays using various two-piece hybrid (TPH) pillars, where each pillar consists of two individual pieces separated by a tunable inter-piece channel. In comparison with the conventional one-piece pillars, the back piece of TPH-pillars is found to hierarchically tailor the flow profile of the front piece on the basis of the row shift fraction and the inter-piece channel width, resulting in unique tunable multi-scheme separation at low, intermediate, and high row shift fractions, respectively. At the intermediate regime, in particular, the first flow lane that determines the critical separation size could be physically fenced out by the inter-piece channel, and a delicate coupling of hydrodynamic filtration and DLD has been revealed to induce a constant critical size in the whole regime. This work theoretically demonstrates the feasibility and significance of TPH-pillars, which may open up a new direction of the geometry design by exploiting rich multi-piece hybrid structures to expand the versatility of the DLD technique.
Collapse
Affiliation(s)
- Jinliang Zhang
- State Key Laboratory of Materials-Oriented Chemical Engineering, College of Chemical Engineering, Nanjing Tech University, Nanjing 211816, China
| | - Haoxiang Tang
- State Key Laboratory of Materials-Oriented Chemical Engineering, College of Chemical Engineering, Nanjing Tech University, Nanjing 211816, China
| | - Jianchuan Zhang
- State Key Laboratory of Materials-Oriented Chemical Engineering, College of Chemical Engineering, Nanjing Tech University, Nanjing 211816, China
| | - Zunmin Zhang
- State Key Laboratory of Materials-Oriented Chemical Engineering, College of Chemical Engineering, Nanjing Tech University, Nanjing 211816, China.
| |
Collapse
|
8
|
Hu S, Zhang Q, Ou Z, Dang Y. Particle sorting method based on swirl induction. J Chem Phys 2023; 159:174901. [PMID: 37909455 DOI: 10.1063/5.0170783] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2023] [Accepted: 10/11/2023] [Indexed: 11/03/2023] Open
Abstract
Fluid-based methods for particle sorting demonstrate increasing appeal in many areas of biosciences due to their biocompatibility and cost-effectiveness. Herein, we construct a microfluidic sorting system based on a swirl microchip. The impact of microchannel velocity on the swirl stagnation point as well as particle movement is analyzed through simulation and experiment. Moreover, the quantitative mapping relationship between flow velocity and particle position distribution is established. With this foundation established, a particle sorting method based on swirl induction is proposed. Initially, the particle is captured by a swirl. Then, the Sorting Region into which the particle aims to enter is determined according to the sorting condition and particle characteristic. Subsequently, the velocities of the microchannels are adjusted to control the swirl, which will induce the particle to enter its corresponding Induction Region. Thereafter, the velocities are adjusted again to change the fluid field and drive the particle into a predetermined Sorting Region, hence the sorting is accomplished. We have extensively conducted experiments taking particle size or color as a sorting condition. An outstanding sorting success rate of 98.75% is achieved when dealing with particles within the size range of tens to hundreds of micrometers in radius, which certifies the effectiveness of the proposed sorting method. Compared to the existing sorting techniques, the proposed method offers greater flexibility. The adjustment of sorting conditions or particle parameters no longer requires complex chip redesign, because such sorting tasks can be successfully realized through simple microchannel velocities control.
Collapse
Affiliation(s)
- Shuai Hu
- School of Mechanical and Automotive Engineering, South China University of Technology, Guangzhou 510641, China
| | - Qin Zhang
- School of Mechanical and Automotive Engineering, South China University of Technology, Guangzhou 510641, China
| | - Zhiming Ou
- School of Mechanical and Automotive Engineering, South China University of Technology, Guangzhou 510641, China
| | - Yanping Dang
- School of Mechanical and Automotive Engineering, South China University of Technology, Guangzhou 510641, China
| |
Collapse
|
9
|
Mahani MA, Karimvand AN, Naserifar N. Optimized hybrid dielectrophoretic microchip for separation of bioparticles. J Sep Sci 2023; 46:e2300257. [PMID: 37480169 DOI: 10.1002/jssc.202300257] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2023] [Revised: 07/12/2023] [Accepted: 07/13/2023] [Indexed: 07/23/2023]
Abstract
Point-of-care diagnostics requires a smart separation of particles and/or cells. In this work, the multiorifice fluid fractionation as a passive method and dielectrophoresis-based actuator as an active tool are combined to offer a new device for size-based particle separation. The main objective of the combination of these two well-established techniques is to improve the performance of the multiorifice fluid fractionation by taking advantage of dielectrophoresis-based actuator for separating particles. Initially, by using numerical simulations, the effect of using dielectrophoresis-based actuator in multiorifice fluid fractionation on the separation of particles was investigated, and the size of the device was optimized by 25% compared to a device without dielectrophoresis-based actuator. Also, adding dielectrophoresis-based actuator to multiorifice fluid fractionation can extend the range of flow rates needed for separation. In the absence of dielectrophoresis-based actuator, the separation took place only when the flow rate is 100 μL/min, in the presence of dielectrophoresis-based actuator (20 Vp-p), the separation happened in flow rates ranging from 70 to 120 μL/min.
Collapse
Affiliation(s)
- Moheb Amir Mahani
- Department of Mechanical Engineering, K. N. Toosi University of Technology, Tehran, Iran
| | | | - Naser Naserifar
- Department of Mechanical Engineering, K. N. Toosi University of Technology, Tehran, Iran
| |
Collapse
|
10
|
Tan Kwan Zen N, Zeming KK, Teo KL, Loberas M, Lee J, Goh CR, Yang DH, Oh S, Hui Hoi Po J, Cool SM, Hou HW, Han J. Scalable mesenchymal stem cell enrichment from bone marrow aspirate using deterministic lateral displacement (DLD) microfluidic sorting. LAB ON A CHIP 2023; 23:4313-4323. [PMID: 37702123 DOI: 10.1039/d3lc00379e] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/14/2023]
Abstract
The growing interest in regenerative medicine has opened new avenues for novel cell therapies using stem cells. Bone marrow aspirate (BMA) is an important source of stromal mesenchymal stem cells (MSCs). Conventional MSC harvesting from BMA relies on archaic centrifugation methods, often leading to poor yield due to osmotic stress, high centrifugation force, convoluted workflow, and long experimental time (∼2-3 hours). To address these issues, we have developed a scalable microfluidic technology based on deterministic lateral displacement (DLD) for MSC isolation. This passive, label-free cell sorting method capitalizes on the morphological differences between MSCs and blood cells (platelets and RBCs) for effective separation using an inverted L-shaped pillar array. To improve throughput, we developed a novel multi-chip DLD system that can process 2.5 mL of raw BMA in 20 ± 5 minutes, achieving a 2-fold increase in MSC recovery compared to centrifugation methods. Taken together, we envision that the developed DLD platform will enable fast and efficient isolation of MSCs from BMA for effective downstream cell therapy in clinical settings.
Collapse
Affiliation(s)
- Nicholas Tan Kwan Zen
- Critical Analytics for Manufacturing of Personalized Medicine, Singapore-MIT Alliance for Research and Technology (SMART), 138602, Singapore
- School of Mechanical and Aerospace Engineering, Nanyang Technological University, 639798, Singapore
| | - Kerwin Kwek Zeming
- Critical Analytics for Manufacturing of Personalized Medicine, Singapore-MIT Alliance for Research and Technology (SMART), 138602, Singapore
| | - Kim Leng Teo
- Bioprocessing Technology Institute, Agency for Science, Technology and Research (A*STAR), 138668, Singapore
| | - Mavis Loberas
- NUS Tissue Engineering Program, Life Sciences Institute, National University of Singapore, 117510, Singapore
- Department of Orthopaedic Surgery, Yong Loo Lin School of Medicine, National University Health System, National University of Singapore, 119288, Singapore
| | - Jialing Lee
- Bioprocessing Technology Institute, Agency for Science, Technology and Research (A*STAR), 138668, Singapore
| | - Chin Ren Goh
- Critical Analytics for Manufacturing of Personalized Medicine, Singapore-MIT Alliance for Research and Technology (SMART), 138602, Singapore
| | - Da Hou Yang
- Critical Analytics for Manufacturing of Personalized Medicine, Singapore-MIT Alliance for Research and Technology (SMART), 138602, Singapore
| | - Steve Oh
- Bioprocessing Technology Institute, Agency for Science, Technology and Research (A*STAR), 138668, Singapore
| | - James Hui Hoi Po
- NUS Tissue Engineering Program, Life Sciences Institute, National University of Singapore, 117510, Singapore
- Department of Orthopaedic Surgery, Yong Loo Lin School of Medicine, National University Health System, National University of Singapore, 119288, Singapore
| | - Simon M Cool
- Department of Orthopaedic Surgery, Yong Loo Lin School of Medicine, National University Health System, National University of Singapore, 119288, Singapore
- Institute of Molecular and Cell Biology, Agency for Science, Technology and Research (A*STAR), 138668, Singapore
- School of Chemical Engineering, University of Queensland, Brisbane, 4072, Australia
| | - Han Wei Hou
- Critical Analytics for Manufacturing of Personalized Medicine, Singapore-MIT Alliance for Research and Technology (SMART), 138602, Singapore
- School of Mechanical and Aerospace Engineering, Nanyang Technological University, 639798, Singapore
- Lee Kong Chian School of Medicine, Nanyang Technological University, 308232, Singapore
| | - Jongyoon Han
- Critical Analytics for Manufacturing of Personalized Medicine, Singapore-MIT Alliance for Research and Technology (SMART), 138602, Singapore
- Department of Biological Engineering, Massachusetts Institute of Technology, Cambridge, Massachusetts, 02139, USA
- Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, Massachusetts, 02139, USA.
| |
Collapse
|
11
|
Abedini-Nassab R, Sadeghidelouei N, Shields Iv CW. Magnetophoretic circuits: A review of device designs and implementation for precise single-cell manipulation. Anal Chim Acta 2023; 1272:341425. [PMID: 37355317 DOI: 10.1016/j.aca.2023.341425] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2023] [Revised: 05/18/2023] [Accepted: 05/24/2023] [Indexed: 06/26/2023]
Abstract
Lab-on-a-chip tools have played a pivotal role in advancing modern biology and medicine. A key goal in this field is to precisely transport single particles and cells to specific locations on a chip for quantitative analysis. To address this large and growing need, magnetophoretic circuits have been developed in the last decade to manipulate a large number of single bioparticles in a parallel and highly controlled manner. Inspired by electrical circuits, magnetophoretic circuits are composed of passive and active circuit elements to offer commensurate levels of control and automation for transporting individual bioparticles. These specifications make them unique compared to other technologies in addressing crucial bioanalytical applications and answering fundamental questions buried in highly heterogeneous cell populations. In this comprehensive review, we describe key theoretical considerations for manufacturing and simulating magnetophoretic circuits. We provide a detailed tutorial for operating magnetophoretic devices containing different circuit elements (e.g., conductors, diodes, capacitors, and transistors). Finally, we provide a critical comparison of the utility of these devices to other microchip-based platforms for cellular manipulation, and discuss how they may address unmet needs in single-cell biology and medicine.
Collapse
Affiliation(s)
- Roozbeh Abedini-Nassab
- Faculty of Mechanical Engineering, Tarbiat Modares University, Tehran, P.O. Box: 14115-111, Iran.
| | - Negar Sadeghidelouei
- Faculty of Mechanical Engineering, Tarbiat Modares University, Tehran, P.O. Box: 14115-111, Iran
| | - C Wyatt Shields Iv
- Department of Chemical and Biological Engineering, University of Colorado, Boulder, CO, 80303, United States
| |
Collapse
|
12
|
Ebrahimi S, Alishiri M, Pishbin E, Afjoul H, Shamloo A. A curved expansion-contraction microfluidic structure for inertial based separation of circulating tumor cells from blood samples. J Chromatogr A 2023; 1705:464200. [PMID: 37429078 DOI: 10.1016/j.chroma.2023.464200] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2023] [Revised: 06/27/2023] [Accepted: 07/04/2023] [Indexed: 07/12/2023]
Abstract
The rare presence of circulating tumor cells (CTCs) in the bloodstream has made their recording and separation one of the major challenges in the recent decade. Inertia-based microfluidic systems have received more attention in CTCs separation due to their feasibility and low cost. In this research, an inertial microfluidic system is proposed using a curved expansion-contraction array (CEA) microchannel to separate CTCs from white blood cells (WBCs). First, the optimal flow rate of the proposed microfluidic device was determined to maximize the separation efficiency of the target cells (CTCs) from the non-target ones (WBCs). Then, the efficiency and purity of the straight and curved-CEA microchannels were assessed. The experimental results indiated that the proposed system (curved-CEA microchannel) can offer the highest efficiency (-80.31%) and purity (-91.32%) at the flow rate of -7.5 ml/min, exhibiting ∼11.48% increment in the efficiency compared to its straight peer.
Collapse
Affiliation(s)
- Sina Ebrahimi
- Nano-Bioengineering Lab, Department of Mechanical Engineering, Sharif University of Technology, Azadi Ave., Tehran 11365-11155, Iran; Stem Cell and Regenerative Medicine Institute, Sharif University of Technology, Tehran 11155-9161, Iran
| | - Mojgan Alishiri
- Nano-Bioengineering Lab, Department of Mechanical Engineering, Sharif University of Technology, Azadi Ave., Tehran 11365-11155, Iran
| | - Esmail Pishbin
- Nano-Bioengineering Lab, Department of Mechanical Engineering, Sharif University of Technology, Azadi Ave., Tehran 11365-11155, Iran; Bio-microfluidics lab, Department of Electrical Engineering and Information Technology, Iranian Research Organization for Science and Technology, Tehran, Iran
| | - Homa Afjoul
- Nano-Bioengineering Lab, Department of Mechanical Engineering, Sharif University of Technology, Azadi Ave., Tehran 11365-11155, Iran; Stem Cell and Regenerative Medicine Institute, Sharif University of Technology, Tehran 11155-9161, Iran
| | - Amir Shamloo
- Nano-Bioengineering Lab, Department of Mechanical Engineering, Sharif University of Technology, Azadi Ave., Tehran 11365-11155, Iran; Stem Cell and Regenerative Medicine Institute, Sharif University of Technology, Tehran 11155-9161, Iran.
| |
Collapse
|
13
|
Choi HJ, Ahn G, Yu US, Kim EJ, Ahn JY, Chan Jeong O. Pneumatically Driven Microfluidic Platform and Fully Automated Particle Concentration System for the Capture and Enrichment of Pathogens. ACS OMEGA 2023; 8:28344-28354. [PMID: 37576663 PMCID: PMC10413479 DOI: 10.1021/acsomega.3c02264] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/04/2023] [Accepted: 07/14/2023] [Indexed: 08/15/2023]
Abstract
In this study, we developed a pneumatically driven microfluidic platform (PDMFP) operated by a fully automated particle concentration system (FAPCS) for the pretreatment of micro- and nano-sized materials. The proposed PDMFP comprises a 3D network with a curved fluidic chamber and channel, five on/off pneumatic valves for blocking fluid flow, and a sieve valve for sequential trapping of microbeads and target particles. Using this setup, concentrated targets are automatically released into an outlet port. The FAPCS mainly comprises solenoid valves, glass reservoirs, a regulator, pressure sensor, main printed circuit board, and liquid crystal display touch panel. All pneumatic valves in the microfluidic platform as well as the working fluids in the glass reservoirs are controlled using FAPCS. The flow rate of the working fluids is measured to demonstrate the sequential programed operation of the proposed pretreatment process using FAPCS. In our study, we successfully achieved rapid and efficient enrichment using PDMFP-FAPCS with fluorescence-labeled Escherichia coli. With pretreatment-10 min for the microbead concentration and 25 min for target binding-almost all the target bacteria could be captured. A total of 526 Gram-negative bacteria were attached to 82 beads, whereas Gram-positive bacteria were attached to only 2 of the 100 beads. Finally, we evaluated the PDMFP-FAPCS for SARS-CoV-2 receptor-binding domain (RBD)-based outer membrane vesicles (OMVs) (RBD-OMVs). Specific probes involved in PDMFP-FAPCS successfully isolated RBD-OMVs. Thus, PDMFP-FAPCS exhibits excellent enrichment of particles, including microbes and nanovesicles, and is an effective pretreatment platform for disease diagnosis and investigation.
Collapse
Affiliation(s)
- Hong Jin Choi
- Department
of Digital Anti-Aging Health Care, Inje
University - Gimhae Campus, Gimhae 50834, Republic of Korea
| | - Gna Ahn
- Center
for Ecology and Environmental Toxicology, Chungbuk National University, Cheongju 28644, Republic of Korea
| | - U Seok Yu
- Department
of Biomedical Engineering, Inje University
- Gimhae Campus, Gimhae 50834, Republic of Korea
| | - Eun Jin Kim
- Department
of Digital Anti-Aging Health Care, Inje
University - Gimhae Campus, Gimhae 50834, Republic of Korea
| | - Ji-Young Ahn
- Center
for Ecology and Environmental Toxicology, Chungbuk National University, Cheongju 28644, Republic of Korea
- Department
of Microbiology, Chungbuk National University, Cheongju 28644, Republic of Korea
| | - Ok Chan Jeong
- Department
of Digital Anti-Aging Health Care, Inje
University - Gimhae Campus, Gimhae 50834, Republic of Korea
- Department
of Biomedical Engineering, Inje University
- Gimhae Campus, Gimhae 50834, Republic of Korea
| |
Collapse
|
14
|
Yao Y, He L, Mei L, Weng Y, Huang J, Wei S, Li R, Tian S, Liu P, Ruan X, Wang D, Zhou F, Lei C. Cell damage evaluation by intelligent imaging flow cytometry. Cytometry A 2023; 103:646-654. [PMID: 36966466 DOI: 10.1002/cyto.a.24731] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2022] [Revised: 02/22/2023] [Accepted: 03/21/2023] [Indexed: 03/27/2023]
Abstract
Essential thrombocythemia (ET) is an uncommon situation in which the body produces too many platelets. This can cause blood clots anywhere in the body and results in various symptoms and even strokes or heart attacks. Removing excessive platelets using acoustofluidic methods receives extensive attention due to their high efficiency and high yield. While the damage to the remaining cells, such as erythrocytes and leukocytes is yet evaluated. Existing cell damage evaluation methods usually require cell staining, which are time-consuming and labor-intensive. In this paper, we investigate cell damage by optical time-stretch (OTS) imaging flow cytometry with high throughput and in a label-free manner. Specifically, we first image the erythrocytes and leukocytes sorted by acoustofluidic sorting chip with different acoustic wave powers and flowing speed using OTS imaging flow cytometry at a flowing speed up to 1 m/s. Then, we employ machine learning algorithms to extract biophysical phenotypic features from the cellular images, as well as to cluster and identify images. The results show that both the errors of the biophysical phenotypic features and the proportion of abnormal cells are within 10% in the undamaged cell groups, while the errors are much greater than 10% in the damaged cell groups, indicating that acoustofluidic sorting causes little damage to the cells within the appropriate acoustic power, agreeing well with clinical assays. Our method provides a novel approach for high-throughput and label-free cell damage evaluation in scientific research and clinical settings.
Collapse
Affiliation(s)
- Yifan Yao
- The Institute of Technological Sciences, Wuhan University, Wuhan, China
| | - Li He
- Department of Hematology, Zhongnan Hospital of Wuhan University, Wuhan, China
| | - Liye Mei
- The Institute of Technological Sciences, Wuhan University, Wuhan, China
| | - Yueyun Weng
- The Institute of Technological Sciences, Wuhan University, Wuhan, China
- The Key Laboratory of Transients in Hydraulic Machinery of Ministry of Education, School of Power and Mechanical Engineering, Wuhan University, Wuhan, China
| | - Jin Huang
- The Institute of Technological Sciences, Wuhan University, Wuhan, China
| | - Shubin Wei
- The Institute of Technological Sciences, Wuhan University, Wuhan, China
| | - Rubing Li
- The Institute of Technological Sciences, Wuhan University, Wuhan, China
| | - Sheng Tian
- Department of Hematology, Zhongnan Hospital of Wuhan University, Wuhan, China
| | - Pan Liu
- Department of Hematology, Zhongnan Hospital of Wuhan University, Wuhan, China
| | - Xiaolan Ruan
- Department of Hematology, Renmin Hospital of Wuhan University, Wuhan, China
| | - Du Wang
- The Institute of Technological Sciences, Wuhan University, Wuhan, China
| | - Fuling Zhou
- Department of Hematology, Zhongnan Hospital of Wuhan University, Wuhan, China
| | - Cheng Lei
- The Institute of Technological Sciences, Wuhan University, Wuhan, China
- Suzhou Institute of Wuhan University, Suzhou, China
| |
Collapse
|
15
|
Adel M, Allam A, Sayour AE, Ragai HF, Umezu S, Fath El-Bab AMR. Fabrication of Spiral Low-Cost Microchannel with Trapezoidal Cross Section for Cell Separation Using a Grayscale Approach. MICROMACHINES 2023; 14:1340. [PMID: 37512651 PMCID: PMC10384897 DOI: 10.3390/mi14071340] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/06/2023] [Revised: 06/25/2023] [Accepted: 06/28/2023] [Indexed: 07/30/2023]
Abstract
Trapezoidal cross-sectional spiral microfluidic channels showed high resolution and throughput in cell separation in bio-applications. The main challenges are the complexity and high cost of the fabrication process of trapezoidal cross-sectional channels on the micro-scale. In this work, we present the application of grayscale in microfluidic channel design to overcome the complexity of the fabrication process. We also use direct engraving with a CO2 laser beam on polymethyl methacrylate (PMMA) material to drastically reduce the microfluidic chip's cost (to <30 cents) and fabrication time (to 20 min). The capability of the present fabrication methodology for cell sorting applications is demonstrated through experimental tests for the separation of white blood cells (WBCs) from whole blood at different dilution factors. The experimental results indicated that an 800 µL/min flow rate provided the optimal separation efficiency using the fabricated chip. A 90.14% separation efficiency at 1% hematocrit diluted blood sample was reported.
Collapse
Affiliation(s)
- Mohamed Adel
- Department of Mechatronics and Robotics Engineering, Egypt-Japan University of Science and Technology (E-JUST), Alexandria 21934, Egypt
- Mechanical Engineering Department, Helwan University, Cairo 11792, Egypt
| | - Ahmed Allam
- Department of Electronics and Communications Engineering, Egypt-Japan University of Science and Technology (E-JUST), Alexandria 21934, Egypt
| | - Ashraf E Sayour
- Molecular Biomimetics Research Group, Animal Health Research Institute, Agricultural Research Center, Giza 12618, Egypt
| | - Hani F Ragai
- Electronics and Communications Department, Faculty of Engineering, Ain Shams University, Cairo 11517, Egypt
| | - Shinjiro Umezu
- Department of Modern Mechanical Engineering, Waseda University, 3-4-1 Okubo, Shinjuku-ku, Tokyo 169-8555, Japan
| | - Ahmed M R Fath El-Bab
- Department of Mechatronics and Robotics Engineering, Egypt-Japan University of Science and Technology (E-JUST), Alexandria 21934, Egypt
| |
Collapse
|
16
|
Farahinia A, Zhang W, Badea I. Recent Developments in Inertial and Centrifugal Microfluidic Systems along with the Involved Forces for Cancer Cell Separation: A Review. SENSORS (BASEL, SWITZERLAND) 2023; 23:s23115300. [PMID: 37300027 DOI: 10.3390/s23115300] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/07/2023] [Revised: 04/23/2023] [Accepted: 05/17/2023] [Indexed: 06/12/2023]
Abstract
The treatment of cancers is a significant challenge in the healthcare context today. Spreading circulating tumor cells (CTCs) throughout the body will eventually lead to cancer metastasis and produce new tumors near the healthy tissues. Therefore, separating these invading cells and extracting cues from them is extremely important for determining the rate of cancer progression inside the body and for the development of individualized treatments, especially at the beginning of the metastasis process. The continuous and fast separation of CTCs has recently been achieved using numerous separation techniques, some of which involve multiple high-level operational protocols. Although a simple blood test can detect the presence of CTCs in the blood circulation system, the detection is still restricted due to the scarcity and heterogeneity of CTCs. The development of more reliable and effective techniques is thus highly desired. The technology of microfluidic devices is promising among many other bio-chemical and bio-physical technologies. This paper reviews recent developments in the two types of microfluidic devices, which are based on the size and/or density of cells, for separating cancer cells. The goal of this review is to identify knowledge or technology gaps and to suggest future works.
Collapse
Affiliation(s)
- Alireza Farahinia
- Department of Mechanical Engineering, University of Saskatchewan, Saskatoon, SK S7N 5A9, Canada
| | - Wenjun Zhang
- Department of Mechanical Engineering, University of Saskatchewan, Saskatoon, SK S7N 5A9, Canada
| | - Ildiko Badea
- College of Pharmacy and Nutrition, University of Saskatchewan, Saskatoon, SK S7N 5E5, Canada
| |
Collapse
|
17
|
Morales Navarrete P, Tjon KCE, Hosseini Z, Yuan J. High-gradient magnetophoretic bead trapping for enhanced electrochemical sensing and particle manipulation. LAB ON A CHIP 2023; 23:2016-2028. [PMID: 36891683 DOI: 10.1039/d2lc01037b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/18/2023]
Abstract
Magnetic particles are routinely used in many biochemical techniques. As such, the manipulation of these particles is of paramount importance for proper detection and assay preparation. This paper describes a magnetic manipulation and detection paradigm that allows sensing and handling highly sensitive magnetic bead-based assays. The simple manufacturing process presented in this manuscript employs a CNC machining technique and an iron microparticle-doped PDMS (Fe-PDMS) compound to create magnetic microstructures that enhance magnetic forces for magnetic bead confinement. Said confinement, generates increases in local concentrations at the detection site. Higher local concentrations increase the magnitude of the detection signal, leading to higher assay sensitivity and lower limit of detection (LOD). Furthermore, we demonstrate this characteristic signal enhancement in both fluorescence and electrochemical detection techniques. We expect this new technique to allow users to design fully integrated magnetic bead-based microfluidic devices with the goal of preventing sample losses and enhancing signal magnitudes in biological experiments and assays.
Collapse
Affiliation(s)
- Pablo Morales Navarrete
- Department of Electronic and Computer Engineering, Hong Kong University of Science and Technology, Clear Water Bay, N.T., Hong Kong.
| | - Kai Chun Eddie Tjon
- Department of Electronic and Computer Engineering, Hong Kong University of Science and Technology, Clear Water Bay, N.T., Hong Kong.
| | - Zahrasadat Hosseini
- Department of Electronic and Computer Engineering, Hong Kong University of Science and Technology, Clear Water Bay, N.T., Hong Kong.
| | - Jie Yuan
- Department of Electronic and Computer Engineering, Hong Kong University of Science and Technology, Clear Water Bay, N.T., Hong Kong.
| |
Collapse
|
18
|
Wu J, Fang H, Zhang J, Yan S. Modular microfluidics for life sciences. J Nanobiotechnology 2023; 21:85. [PMID: 36906553 PMCID: PMC10008080 DOI: 10.1186/s12951-023-01846-x] [Citation(s) in RCA: 12] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2023] [Accepted: 03/06/2023] [Indexed: 03/13/2023] Open
Abstract
The advancement of microfluidics has enabled numerous discoveries and technologies in life sciences. However, due to the lack of industry standards and configurability, the design and fabrication of microfluidic devices require highly skilled technicians. The diversity of microfluidic devices discourages biologists and chemists from applying this technique in their laboratories. Modular microfluidics, which integrates the standardized microfluidic modules into a whole, complex platform, brings the capability of configurability to conventional microfluidics. The exciting features, including portability, on-site deployability, and high customization motivate us to review the state-of-the-art modular microfluidics and discuss future perspectives. In this review, we first introduce the working mechanisms of the basic microfluidic modules and evaluate their feasibility as modular microfluidic components. Next, we explain the connection approaches among these microfluidic modules, and summarize the advantages of modular microfluidics over integrated microfluidics in biological applications. Finally, we discuss the challenge and future perspectives of modular microfluidics.
Collapse
Affiliation(s)
- Jialin Wu
- Institute for Advanced Study, Shenzhen University, Shenzhen, 518060, China
- Nanophotonics Research Center, Institute of Microscale Optoelectronics, Shenzhen University, Shenzhen, China
| | - Hui Fang
- Nanophotonics Research Center, Institute of Microscale Optoelectronics, Shenzhen University, Shenzhen, China
| | - Jun Zhang
- Queensland Micro and Nanotechnology Centre, Griffith University, Brisbane, QLD, 4111, Australia
| | - Sheng Yan
- Institute for Advanced Study, Shenzhen University, Shenzhen, 518060, China.
| |
Collapse
|
19
|
Lei W, Lu X, Wang M. Multiphase displacement manipulated by micro/nanoparticle suspensions in porous media via microfluidic experiments: From interface science to multiphase flow patterns. Adv Colloid Interface Sci 2023; 311:102826. [PMID: 36528919 DOI: 10.1016/j.cis.2022.102826] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2022] [Revised: 12/04/2022] [Accepted: 12/09/2022] [Indexed: 12/15/2022]
Abstract
Multiphase displacement in porous media can be adjusted by micro/nanoparticle suspensions, which is widespread in many scientific and industrial contexts. Direct visualization of suspension flow dynamics and corresponding multiphase patterns is crucial to understanding displacement mechanisms and eventually optimizing these processes in geological, biological, chemical, and other engineering systems. However, suspension flow inside the opaque realistic porous media makes direct observation challenging. The advances in microfluidic experiments have provided us with alternative methods to observe suspension influence on the interface and multiphase flow behaviors at high temporal and spatial resolutions. Macroscale processes are controlled by microscale interfacial behaviors, which are affected by multiple physical factors, such as particle adsorption, capillarity, and hydrodynamics. These properties exerted on the suspension flow in porous media may lead to interesting interfacial phenomena and new displacement consequences. As an underpinning science, understanding and controlling the suspension transport process from interface to flow patterns in porous media is critical for a lower operating cost to improve resource production while reducing harmful emissions and other environmental impacts. This review summarizes the basic properties of different micro/nanoparticle suspensions and the state-of-the-art microfluidic techniques for displacement research activities in porous media. Various suspension transport behaviors and displacement mechanisms explored by microfluidic experiments are comprehensively reviewed. This review is expected to boost both experimental and theoretical understanding of suspension transport and interfacial interaction processes in porous media. It also brings forward the challenges and opportunities for future research in controlling complex fluid flow in porous media for diverse applications.
Collapse
Affiliation(s)
- Wenhai Lei
- Department of Engineering Mechanics, Tsinghua University, Beijing 100084, China
| | - Xukang Lu
- Department of Engineering Mechanics, Tsinghua University, Beijing 100084, China
| | - Moran Wang
- Department of Engineering Mechanics, Tsinghua University, Beijing 100084, China.
| |
Collapse
|
20
|
Naderi MM, Barilla L, Zhou J, Papautsky I, Peng Z. Elasto-Inertial Focusing Mechanisms of Particles in Shear-Thinning Viscoelastic Fluid in Rectangular Microchannels. MICROMACHINES 2022; 13:mi13122131. [PMID: 36557430 PMCID: PMC9781382 DOI: 10.3390/mi13122131] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/21/2022] [Revised: 11/24/2022] [Accepted: 11/26/2022] [Indexed: 06/01/2023]
Abstract
Growth of the microfluidics field has triggered numerous advances in focusing and separating microparticles, with such systems rapidly finding applications in biomedical, chemical, and environmental fields. The use of shear-thinning viscoelastic fluids in microfluidic channels is leading to evolution of elasto-inertial focusing. Herein, we showed that the interplay between the elastic and shear-gradient lift forces, as well as the secondary flow transversal drag force that is caused by the non-zero second normal stress difference, lead to different particle focusing patterns in the elasto-inertial regime. Experiments and 3D simulations were performed to study the effects of flowrate, particle size, and the shear-thinning extent of the fluid on the focusing patterns. The Giesekus constitutive equation was used in the simulations to capture the shear-thinning and viscoelastic behaviors of the solution used in the experiments. At low flowrate, with Weissenberg number Wi ~ O(1), both the elastic force and secondary flow effects push particles towards the channel center. However, at a high flowrate, Wi ~ O(10), the elastic force direction is reversed in the central regions. This remarkable behavior of the elastic force, combined with the enhanced shear-gradient lift at the high flowrate, pushes particles away from the channel center. Additionally, a precise prediction of the focusing position can only be made when the shear-thinning extent of the fluid is correctly estimated in the modeling. The shear-thinning also gives rise to the unique behavior of the inertial forces near the channel walls which is linked with the ‘warped’ velocity profile in such fluids.
Collapse
Affiliation(s)
| | | | | | - Ian Papautsky
- Correspondence: (I.P.); (Z.P.); Tel.: +1-312-413-3800 (I.P.); +1-312-996-7467 (Z.P.)
| | - Zhangli Peng
- Correspondence: (I.P.); (Z.P.); Tel.: +1-312-413-3800 (I.P.); +1-312-996-7467 (Z.P.)
| |
Collapse
|
21
|
Shirai K, Guan G, Meihui T, Xiaoling P, Oka Y, Takahashi Y, Bhagat AAS, Yanagida M, Iwanaga S, Matsubara N, Mukohara T, Yoshida T. Hybrid double-spiral microfluidic chip for RBC-lysis-free enrichment of rare cells from whole blood. LAB ON A CHIP 2022; 22:4418-4429. [PMID: 36305222 DOI: 10.1039/d2lc00713d] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
Abstract
Drug selection and treatment monitoring via minimally invasive liquid biopsy using circulating tumor cells (CTCs) are expected to be realized in the near future. For clinical applications of CTCs, simple, high-throughput, single-step CTC isolation from whole blood without red blood cell (RBC) lysis and centrifugation remains a crucial challenge. In this study, we developed a novel cancer cell separation chip, "hybrid double-spiral chip", that involves the serial combination of two different Dean flow fractionation (DFF) separation modes of half and full Dean cycles, which is the hybrid DFF separation mode for ultra-high-throughput blood processing at high precision and size-resolution separation. The chip allows fast processing of 5 mL whole blood within 30 min without RBC lysis and centrifugation. RBC and white blood cell (WBC) depletion rates of over 99.9% and 99%, respectively, were achieved. The average recovery rate of spiked A549 cancer cells was 87% with as low as 200 cells in 5 mL blood. The device can achieve serial reduction in the number of cells from approximately 1010 cells of whole blood to 108 cells, and subsequently to an order of 106 cells. The developed method can be combined with measurements of all recovered cells using imaging flow cytometry. As proof of concept, CTCs were successfully enriched and enumerated from the blood of metastatic breast cancer patients (N = 10, 1-69 CTCs per 5 mL) and metastatic prostate cancer patients (N = 10, 1-39 CTCs per 5 mL). We believe that the developed method will be beneficial for automated clinical analysis of rare CTCs from whole blood.
Collapse
Affiliation(s)
- Kentaro Shirai
- Sysmex Corporation, 4-4-4, Takatsuka-dai, Nishi-ku, Kobe, Hyogo, Japan.
| | - Guofeng Guan
- Biolidics Limited, 37 Jalan Pemimpin, 577177 Singapore
| | - Tan Meihui
- Biolidics Limited, 37 Jalan Pemimpin, 577177 Singapore
| | - Peng Xiaoling
- Sysmex Corporation, 4-4-4, Takatsuka-dai, Nishi-ku, Kobe, Hyogo, Japan.
| | - Yuma Oka
- Sysmex Corporation, 4-4-4, Takatsuka-dai, Nishi-ku, Kobe, Hyogo, Japan.
| | - Yusuke Takahashi
- Sysmex Corporation, 4-4-4, Takatsuka-dai, Nishi-ku, Kobe, Hyogo, Japan.
| | | | | | - Shigeki Iwanaga
- Sysmex Corporation, 4-4-4, Takatsuka-dai, Nishi-ku, Kobe, Hyogo, Japan.
| | - Nobuaki Matsubara
- Department of Medical Oncology, National Cancer Center Hospital East, Kashiwanoha, Kashiwa, Japan
| | - Toru Mukohara
- Department of Medical Oncology, National Cancer Center Hospital East, Kashiwanoha, Kashiwa, Japan
| | - Tomokazu Yoshida
- Sysmex Corporation, 4-4-4, Takatsuka-dai, Nishi-ku, Kobe, Hyogo, Japan.
| |
Collapse
|
22
|
Amani A, Shamloo A, Vatani P, Ebrahimi S. Particles Focusing and Separation by a Novel Inertial Microfluidic Device: Divergent Serpentine Microchannel. Ind Eng Chem Res 2022. [DOI: 10.1021/acs.iecr.2c02451] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- Ali Amani
- School of Mechanical Engineering, Sharif University of Technology, Tehran 11365-8639, Iran
| | - Amir Shamloo
- School of Mechanical Engineering, Sharif University of Technology, Tehran 11365-8639, Iran
| | - Pouyan Vatani
- School of Mechanical Engineering, Sharif University of Technology, Tehran 11365-8639, Iran
| | - Sina Ebrahimi
- School of Mechanical Engineering, Sharif University of Technology, Tehran 11365-8639, Iran
| |
Collapse
|
23
|
Barbosa VB, Rodrigues CF, Cerqueira L, Miranda JM, Azevedo NF. Microfluidics combined with fluorescence in situ hybridization (FISH) for Candida spp. detection. Front Bioeng Biotechnol 2022; 10:987669. [PMID: 36213081 PMCID: PMC9539416 DOI: 10.3389/fbioe.2022.987669] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2022] [Accepted: 08/08/2022] [Indexed: 11/13/2022] Open
Abstract
One of the most prevalent healthcare-associated infection is the urinary tract infection (UTI), caused by opportunistic pathogens such as Candida albicans or non-albicans Candida species (NACS). Urine culture methods are routinely used for UTI diagnostics due to their specificity, sensitivity and low-cost. However, these methods are also laborious, time- and reagent-consuming. Therefore, diagnostic methods relying on nucleic acids have been suggested as alternatives. Nucleic acid-based methods can provide results within 24 h and can be adapted to point-of-care (POC) detection. Here, we propose to combine fluorescence in situ hybridization (FISH) with a microfluidic platform for the detection of Candida spp. As a case study we used C. tropicalis, which is reported as the second most common NACS urine isolate obtained from patients suspected with UTI. The microfluidic platform proposed in this study relies on hydrodynamic trapping, and uses physical barriers (e.g., microposts) for the separation of target cells from the suspension. Using a specific peptide nucleic acid (PNA) probe, the FISH procedure was applied onto previously trapped C. tropicalis cells present inside the microfluidic platform. Fluorescence signal intensity of hybridized cells was captured directly under the epifluorescence microscope. Overall, the PNA probe successfully detected C. tropicalis in pure culture and artificial urine (AU) using FISH combined with the microfluidic platform. Our findings reveal that FISH using nucleic acid mimics (PNA) in combination with microfluidics is a reliable method for the detection of microorganisms such as C. tropicalis. As such, this work provides the basis for the development of a POC detection platform in the future.
Collapse
Affiliation(s)
- Violina Baranauskaite Barbosa
- LEPABE–Laboratory for Process Engineering, Environment, Biotechnology and Energy, Department of Chemical Engineering, Faculty of Engineering of University of Porto, Porto, Portugal
- ALiCE–Associate Laboratory in Chemical Engineering, Faculty of Engineering, University of Porto, Porto, Portugal
| | - Célia F. Rodrigues
- LEPABE–Laboratory for Process Engineering, Environment, Biotechnology and Energy, Department of Chemical Engineering, Faculty of Engineering of University of Porto, Porto, Portugal
- ALiCE–Associate Laboratory in Chemical Engineering, Faculty of Engineering, University of Porto, Porto, Portugal
| | - Laura Cerqueira
- LEPABE–Laboratory for Process Engineering, Environment, Biotechnology and Energy, Department of Chemical Engineering, Faculty of Engineering of University of Porto, Porto, Portugal
- ALiCE–Associate Laboratory in Chemical Engineering, Faculty of Engineering, University of Porto, Porto, Portugal
- *Correspondence: Laura Cerqueira, ; João M. Miranda,
| | - João M. Miranda
- ALiCE–Associate Laboratory in Chemical Engineering, Faculty of Engineering, University of Porto, Porto, Portugal
- CEFT–Transport Phenomena Research Center, Department of Chemical Engineering, Faculty of Engineering of University of Porto, Porto, Portugal
- *Correspondence: Laura Cerqueira, ; João M. Miranda,
| | - Nuno F. Azevedo
- LEPABE–Laboratory for Process Engineering, Environment, Biotechnology and Energy, Department of Chemical Engineering, Faculty of Engineering of University of Porto, Porto, Portugal
- ALiCE–Associate Laboratory in Chemical Engineering, Faculty of Engineering, University of Porto, Porto, Portugal
| |
Collapse
|
24
|
Separation of White Blood Cells in a Wavy Type Microfluidic Device Using Blood Diluted in a Hypertonic Saline Solution. BIOCHIP JOURNAL 2022. [DOI: 10.1007/s13206-022-00074-z] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/02/2022]
|
25
|
Wang B, Park B. Microfluidic Sampling and Biosensing Systems for Foodborne Escherichia coli and Salmonella. Foodborne Pathog Dis 2022; 19:359-375. [PMID: 35713922 DOI: 10.1089/fpd.2021.0087] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022] Open
Abstract
Developments of portable biosensors for field-deployable detections have been increasingly important to control foodborne pathogens in regulatory environment and in early stage of outbreaks. Conventional cultivation and gene amplification methods require sophisticated instruments and highly skilled professionals; while portable biosensing devices provide more freedom for rapid detections not only in research laboratories but also in the field; however, their sensitivity and specificity are limited. Microfluidic methods have the advantage of miniaturizing instrumental size while integrating multiple functions and high-throughput capability into one streamlined system at low cost. Minimal sample consumption is another advantage to detect samples in different sizes and concentrations, which is important for the close monitoring of pathogens at consumer end. They improve measurement or manipulation of bacteria by increasing the ratio of functional interface of the device to the targeted biospecies and in turn reducing background interference. This article introduces the major active and passive microfluidic devices that have been used for bacteria sampling and biosensing. The emphasis is on particle-based sorting/enrichment methods with or without external physical fields applied to the microfluidic devices and on various biosensing applications reported for bacteria sampling. Three major fabrication methods for microfluidics are briefly discussed with their advantages and limitations. The applications of these active and passive microfluidic sampling methods in the past 5 years have been summarized, with the focus on Escherichia coli and Salmonella. The current challenges to microfluidic bacteria sampling are caused by the small size and nonspherical shape of various bacterial cells, which can induce unpredictable deviations in sampling and biosensing processes. Future studies are needed to develop rapid prototyping methods for device manufacturing, which can facilitate rapid response to various foodborne pathogen outbreaks.
Collapse
Affiliation(s)
- Bin Wang
- U.S. National Poultry Research Center, Agricultural Research Service, U.S. Department of Agriculture, Athens, Georgia, USA
| | - Bosoon Park
- U.S. National Poultry Research Center, Agricultural Research Service, U.S. Department of Agriculture, Athens, Georgia, USA
| |
Collapse
|
26
|
Zheng W, Xie R, Liang X, Liang Q. Fabrication of Biomaterials and Biostructures Based On Microfluidic Manipulation. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2022; 18:e2105867. [PMID: 35072338 DOI: 10.1002/smll.202105867] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/25/2021] [Revised: 12/22/2021] [Indexed: 06/14/2023]
Abstract
Biofabrication technologies are of importance for the construction of organ models and functional tissue replacements. Microfluidic manipulation, a promising biofabrication technique with micro-scale resolution, can not only help to realize the fabrication of specific microsized structures but also build biomimetic microenvironments for biofabricated tissues. Therefore, microfluidic manipulation has attracted attention from researchers in the manipulation of particles and cells, biochemical analysis, tissue engineering, disease diagnostics, and drug discovery. Herein, biofabrication based on microfluidic manipulation technology is reviewed. The application of microfluidic manipulation technology in the manufacturing of biomaterials and biostructures with different dimensions and the control of the microenvironment is summarized. Finally, current challenges are discussed and a prospect of microfluidic manipulation technology is given. The authors hope this review can provide an overview of microfluidic manipulation technologies used in biofabrication and thus steer the current efforts in this field.
Collapse
Affiliation(s)
- Wenchen Zheng
- Department of Chemistry, Tsinghua University, Beijing, 100084, China
| | - Ruoxiao Xie
- Department of Chemistry, Tsinghua University, Beijing, 100084, China
| | - Xiaoping Liang
- School of Biomedical and Pharmaceutical Sciences, Guangdong University of Technology, Guangdong, 510006, China
| | - Qionglin Liang
- Department of Chemistry, Tsinghua University, Beijing, 100084, China
| |
Collapse
|
27
|
Nasiri R, Shamloo A, Akbari J. Design of two Inertial-based microfluidic devices for cancer cell separation from Blood: A serpentine inertial device and an integrated inertial and magnetophoretic device. Chem Eng Sci 2022. [DOI: 10.1016/j.ces.2021.117283] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|
28
|
Fabrication of a new all-in-one microfluidic dielectrophoresis integrated chip and living cell separation. iScience 2022; 25:103776. [PMID: 35146391 PMCID: PMC8819401 DOI: 10.1016/j.isci.2022.103776] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2021] [Revised: 11/16/2021] [Accepted: 01/11/2022] [Indexed: 11/22/2022] Open
Abstract
Microfluidic dielectrophoresis (DEP) technology has been applied to many devices to perform label-free target cell separation. Cells separated by these devices are used in laboratories, mainly for medical research. The present study designed a microfluidic DEP device to fabricate a rapid and semiautomated cell separation system in conjunction with microscopy to enumerate the separated cells. With this device, we efficiently segregated bacterial cells from liquid products and enriched one cell type from two mixed eukaryotic cell types. The device eliminated sample pretreatment and established cell separation by all-in-one operation in a lab-on-chip, requiring only a small sample volume (0.5–1 mL) to enumerate the target cells and completing the entire separation process within 30 min. Such a rapid cell separation technique is in high demand by many researchers to promptly characterize the target cells. A new all-in-one microfluidic dielectrophoresis integrated chip is fabricated Simultaneous operation of buffer exchange and continuous cell separation on a chip Chip’s cell separation performance is evaluated with bacterial and eukaryotic cells
Collapse
|
29
|
Ning S, Liu S, Xiao Y, Zhang G, Cui W, Reed M. A microfluidic chip with a serpentine channel enabling high-throughput cell separation using surface acoustic waves. LAB ON A CHIP 2021; 21:4608-4617. [PMID: 34763349 DOI: 10.1039/d1lc00840d] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/14/2023]
Abstract
As an acute inflammatory response, sepsis may cause septic shock and multiple organ failure. Rapid and reliable detection of pathogens from blood samples can promote early diagnosis and treatment of sepsis. However, traditional pathogen detection methods rely on bacterial blood culture, which is complex and time-consuming. Although pre-separation of bacteria from blood can help with the identification of pathogens for diagnosis, the required low-velocity fluid environment of most separation techniques greatly limits the processing capacity for blood samples. Here, we present an acoustofluidic device for high-throughput bacterial separation from human blood cells. Our device utilizes a serpentine microfluidic design and standing surface acoustic waves (SSAWs), and separates bacteria from blood cells effectively based on their size difference. The serpentine microstructure allows the operating distance of the acoustic field to be multiplied in a limited chip size via the "spatial multiplexing" and "pressure node matching" of SSAW field. Microscopic observation and flow cytometry analysis shows that the device is helpful in improving the flow rate (2.6 μL min-1 for blood samples; the corresponding velocity is ∼3 cm s-1) without losing separation purity or cell recovery. The serpentine microfluidic design provides a compatible solution for high-throughput separation, which can synergize with other functional designs to improve device performance. Further, its advantages such as low cost, high biocompatibility, label-free separation and ability to integrate with on-chip biosensors are promising for clinical utility in point-of-care diagnostic platforms.
Collapse
Affiliation(s)
- Shupeng Ning
- School of Precision Instrument and Opto-Electronics Engineering, Tianjin University, Tianjin 300072, China.
- State Key Laboratory of Precision Measuring Technology & Instruments, Tianjin 300072, China
| | - Shuchang Liu
- School of Precision Instrument and Opto-Electronics Engineering, Tianjin University, Tianjin 300072, China.
- State Key Laboratory of Precision Measuring Technology & Instruments, Tianjin 300072, China
| | - Yunjie Xiao
- School of Life Sciences, Tianjin University, Tianjin 300072, China
| | - Guanyu Zhang
- School of Precision Instrument and Opto-Electronics Engineering, Tianjin University, Tianjin 300072, China.
- State Key Laboratory of Precision Measuring Technology & Instruments, Tianjin 300072, China
| | - Weiwei Cui
- School of Precision Instrument and Opto-Electronics Engineering, Tianjin University, Tianjin 300072, China.
- State Key Laboratory of Precision Measuring Technology & Instruments, Tianjin 300072, China
| | - Mark Reed
- School of Engineering and Applied Sciences, Yale University, New Haven, CT 06511, USA
| |
Collapse
|
30
|
Fabrication of Microparticles with Front-Back Asymmetric Shapes Using Anisotropic Gelation. MICROMACHINES 2021; 12:mi12091121. [PMID: 34577764 PMCID: PMC8466830 DOI: 10.3390/mi12091121] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/20/2021] [Revised: 09/10/2021] [Accepted: 09/14/2021] [Indexed: 01/13/2023]
Abstract
Droplet-based microfluidics is a powerful tool for producing monodispersed micrometer-sized droplets with controlled sizes and shapes; thus, it has been widely applied in diverse fields from fundamental science to industries. Toward a simpler method for fabricating microparticles with front–back asymmetry in their shapes, we studied anisotropic gelation of alginate droplets, which occurs inside a flow-focusing microfluidic device. In the proposed method, sodium alginate (NaAlg) aqueous phase fused with a calcium chloride (CaCl2) emulsion dispersed in the organic phase just before the aqueous phase breaks up into the droplets. The fused droplet with a front–back asymmetric shape was generated, and the asymmetric shape was kept after geometrical confinement by a narrow microchannel was removed. The shape of the fused droplet depended on the size of prefused NaAlg aqueous phase and a CaCl2 emulsion, and the front–back asymmetry appeared in the case of the smaller emulsion size. The analysis of the velocity field inside and around the droplet revealed that the stagnation point at the tip of the aqueous phase also played an important role. The proposed mechanism will be potentially applicable as a novel fabrication technique of microparticles with asymmetric shapes.
Collapse
|
31
|
Zhang X, Wei X, Men X, Wu CX, Bai JJ, Li WT, Yang T, Chen ML, Wang JH. Dual-Multivalent-Aptamer-Conjugated Nanoprobes for Superefficient Discerning of Single Circulating Tumor Cells in a Microfluidic Chip with Inductively Coupled Plasma Mass Spectrometry Detection. ACS APPLIED MATERIALS & INTERFACES 2021; 13:43668-43675. [PMID: 34473482 DOI: 10.1021/acsami.1c11953] [Citation(s) in RCA: 34] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
The efficient recognition of circulating tumor cells (CTCs) with an aptamer probe confers numerous benefits; however, the stability and binding affinity of aptamers are significantly hampered in real biological sample matrices. Inspired by the efficient preying mechanism by multiplex tubing feet and endoskeletons of sea urchins, we engineered a superefficient biomimetic single-CTC recognition platform by conjugating dual-multivalent-aptamers (DMAs) Sgc8 and SYL3C onto AuNPs to form a sea urchin-like nanoprobe (sea urchin-DMA-AuNPs). Aptamers Sgc8 and SYL3C selectively bind with the biomarker proteins PTK7 and EpCAM expressed on the surface of CTCs. CTCs were captured with 100% efficiency, followed by sorting on a specially designed multifunctional microfluidic configuration, integrating a single-CTC separation unit and a hydrodynamic filtrating purification unit. After sorting, background-free analysis of biomarker proteins in single CTCs was undertaken with inductively coupled plasma mass spectrometry by measuring the amount of 197Au isotope in sea urchin-DMA-AuNPs. With respect to a single-aptamer nanoprobe/-interface, the dual-aptamer nanoprobe improves the binding efficiency by more than 200% (Kd < 0.35 nM). The microchip facilitates the recognition of single CTCs with a sorting separation rate of 93.6% at a flow rate of 60 μL min-1, and it exhibits 73.8 ± 5.0% measurement efficiency for single CTCs. The present strategy ensures the manipulation and detection of a single CTC in 100 μL of whole blood within 1 h.
Collapse
Affiliation(s)
- Xuan Zhang
- Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Box 332, Shenyang 110819, China
| | - Xing Wei
- Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Box 332, Shenyang 110819, China
| | - Xue Men
- Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Box 332, Shenyang 110819, China
| | - Cheng-Xin Wu
- Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Box 332, Shenyang 110819, China
| | - Jun-Jie Bai
- Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Box 332, Shenyang 110819, China
| | - Wei-Tao Li
- Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Box 332, Shenyang 110819, China
| | - Ting Yang
- Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Box 332, Shenyang 110819, China
| | - Ming-Li Chen
- Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Box 332, Shenyang 110819, China
| | - Jian-Hua Wang
- Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Box 332, Shenyang 110819, China
| |
Collapse
|
32
|
Beshay PE, Ibrahim AM, Jeffrey SS, Howe RT, Anis YH. Encapsulated Cell Dynamics in Droplet Microfluidic Devices with Sheath Flow. MICROMACHINES 2021; 12:mi12070839. [PMID: 34357249 PMCID: PMC8304737 DOI: 10.3390/mi12070839] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/04/2021] [Revised: 07/15/2021] [Accepted: 07/16/2021] [Indexed: 11/16/2022]
Abstract
In this paper we study the dynamics of single cells encapsulated in water-in-oil emulsions in a microchannel. The flow field of a microfluidic channel is coupled to the internal flow field of a droplet through viscous traction at the interface, resulting in a rotational flow field inside the droplet. An encapsulated single cell being subjected to this flow field responds by undergoing multiple orbits, spins, and deformations that depend on its physical properties. Monitoring the cell dynamics, using a high-speed camera, can lead to the development of new label-free methods for the detection of rare cells, based on their biomechanical properties. A sheath flow microchannel was proposed to strengthen the rotational flow field inside droplets flowing in Poiseuille flow conditions. A numerical model was developed to investigate the effect of various parameters on the rotational flow field inside a droplet. The multi-phase flow model required the tracking of the fluid–fluid interface, which deforms over time due to the applied shear stresses. Experiments confirmed the significant effect of the sheath flow rate on the cell dynamics, where the speed of cell orbiting was doubled. Doubling the cell speed can double the amount of extracted biomechanical information from the encapsulated cell, while it remains within the field of view of the camera used.
Collapse
Affiliation(s)
- Peter E. Beshay
- Mechanical Design and Production Department, Faculty of Engineering, Cairo University, Giza 12613, Egypt; (P.E.B.); (A.M.I.)
| | - Ali M. Ibrahim
- Mechanical Design and Production Department, Faculty of Engineering, Cairo University, Giza 12613, Egypt; (P.E.B.); (A.M.I.)
| | - Stefanie S. Jeffrey
- Department of Surgery, Stanford University School of Medicine, Stanford, CA 94305, USA;
| | - Roger T. Howe
- Department of Electrical Engineering, Stanford University, Stanford, CA 94305, USA;
| | - Yasser H. Anis
- Mechanical Design and Production Department, Faculty of Engineering, Cairo University, Giza 12613, Egypt; (P.E.B.); (A.M.I.)
- Correspondence:
| |
Collapse
|
33
|
High-Throughput Cell Concentration Using A Piezoelectric Pump in Closed-Loop Viscoelastic Microfluidics. MICROMACHINES 2021; 12:mi12060677. [PMID: 34207912 PMCID: PMC8229193 DOI: 10.3390/mi12060677] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/23/2021] [Revised: 06/01/2021] [Accepted: 06/07/2021] [Indexed: 11/29/2022]
Abstract
Cell concentration is a critical process in biological assays and clinical diagnostics for the pre-treatment of extremely rare disease-related cells. The conventional technique for sample preconcentration and centrifugation has the limitations of a batch process requiring expensive and large equipment. Therefore, a high-throughput continuous cell concentration technique needs to be developed. However, in single-pass operation, the required concentration ratio is hard to achieve. In this study, we propose a closed-loop continuous cell concentration system using a viscoelastic non-Newtonian fluid. For miniaturized and integrated systems, two piezoelectric pumps were adopted. The pumping capability generated by a piezoelectric pump in a microfluidic channel was evaluated depending on the applied voltage, frequency, sample viscosity, and channel length. The concentration performance of the device was evaluated using 13 μm particles and white blood cells (WBCs) with different channel lengths and voltages. In the closed-loop system, the focused cells collected at the center outlet were sent back to the inlet, while the buffer solution was removed to the side outlets. Finally, to expand the clinical applicability of our closed-loop system, WBCs in lysed blood samples with 70% hematocrit and prostate cancer cells in urine samples were used. Using the closed-loop system, WBCs were concentrated by ~63.4 ± 0.8-fold within 20 min to a final volume of 160 μL using 10 mL of lysed blood sample with 70% hematocrit (~3 cP). In addition, prostate cancer cells in 10 mL urine samples were concentrated by ~64.1-fold within ~11 min due to low viscosity (~1 cP).
Collapse
|
34
|
Kwizera EA, Sun M, White AM, Li J, He X. Methods of Generating Dielectrophoretic Force for Microfluidic Manipulation of Bioparticles. ACS Biomater Sci Eng 2021; 7:2043-2063. [PMID: 33871975 DOI: 10.1021/acsbiomaterials.1c00083] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Manipulation of microscale bioparticles including living cells is of great significance to the broad bioengineering and biotechnology fields. Dielectrophoresis (DEP), which is defined as the interactions between dielectric particles and the electric field, is one of the most widely used techniques for the manipulation of bioparticles including cell separation, sorting, and trapping. Bioparticles experience a DEP force if they have a different polarization from the surrounding media in an electric field that is nonuniform in terms of the intensity and/or phase of the electric field. A comprehensive literature survey shows that the DEP-based microfluidic devices for manipulating bioparticles can be categorized according to the methods of creating the nonuniformity via patterned microchannels, electrodes, and media to generate the DEP force. These methods together with the theory of DEP force generation are described in this review, to provide a summary of the methods and materials that have been used to manipulate various bioparticles for various specific biological outcomes. Further developments of DEP-based technologies include identifying materials that better integrate with electrodes than current popular materials (silicone/glass) and improving the performance of DEP manipulation of bioparticles by combining it with other methods of handling bioparticles. Collectively, DEP-based microfluidic manipulation of bioparticles holds great potential for various biomedical applications.
Collapse
Affiliation(s)
- Elyahb A Kwizera
- Fischell Department of Bioengineering, University of Maryland, College Park, Maryland 20742, United States.,Robert E. Fischell Institute for Biomedical Devices, University of Maryland, College Park, Maryland 20742, United States
| | - Mingrui Sun
- Department of Biomedical Engineering, The Ohio State University, Columbus, Ohio 43210, United States
| | - Alisa M White
- Fischell Department of Bioengineering, University of Maryland, College Park, Maryland 20742, United States.,Robert E. Fischell Institute for Biomedical Devices, University of Maryland, College Park, Maryland 20742, United States
| | - Jianrong Li
- Department of Veterinary Biosciences, The Ohio State University, Columbus, Ohio 43210, United States
| | - Xiaoming He
- Fischell Department of Bioengineering, University of Maryland, College Park, Maryland 20742, United States.,Department of Biomedical Engineering, The Ohio State University, Columbus, Ohio 43210, United States.,Robert E. Fischell Institute for Biomedical Devices, University of Maryland, College Park, Maryland 20742, United States.,Marlene and Stewart Greenebaum Comprehensive Cancer Center, University of Maryland, Baltimore, Maryland 21201, United States
| |
Collapse
|
35
|
Public-Health-Driven Microfluidic Technologies: From Separation to Detection. MICROMACHINES 2021; 12:mi12040391. [PMID: 33918189 PMCID: PMC8066776 DOI: 10.3390/mi12040391] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/28/2021] [Revised: 03/25/2021] [Accepted: 03/26/2021] [Indexed: 02/07/2023]
Abstract
Separation and detection are ubiquitous in our daily life and they are two of the most important steps toward practical biomedical diagnostics and industrial applications. A deep understanding of working principles and examples of separation and detection enables a plethora of applications from blood test and air/water quality monitoring to food safety and biosecurity; none of which are irrelevant to public health. Microfluidics can separate and detect various particles/aerosols as well as cells/viruses in a cost-effective and easy-to-operate manner. There are a number of papers reviewing microfluidic separation and detection, but to the best of our knowledge, the two topics are normally reviewed separately. In fact, these two themes are closely related with each other from the perspectives of public health: understanding separation or sorting technique will lead to the development of new detection methods, thereby providing new paths to guide the separation routes. Therefore, the purpose of this review paper is two-fold: reporting the latest developments in the application of microfluidics for separation and outlining the emerging research in microfluidic detection. The dominating microfluidics-based passive separation methods and detection methods are discussed, along with the future perspectives and challenges being discussed. Our work inspires novel development of separation and detection methods for the benefits of public health.
Collapse
|
36
|
AHANDOUST SINA, SAADATMAND MARYAM. COMPUTATIONAL STUDY OF GEOMETRIC EFFECTS OF BOTTOM WALL MICROGROOVES ON CELL DOCKING INSIDE MICROFLUIDIC DEVICES. J MECH MED BIOL 2021. [DOI: 10.1142/s0219519421500172] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Cells docking inside microfluidic devices is effective in studying cell biology, cell-based biosensing, as well as drug screening. Furthermore, single cell and regularly cells docking inside the microstructure of microfluidic systems are advantageous in different analyses of single cells exposed to equal drug concentration and mechanical stimulus. In this study, we investigated bottom wall microgrooves with semicircular and rectangular geometries with different sizes which are suitable for single cell docking along the length of the microgroove in [Formula: see text]-direction and numerous cells docking regularly in one line inside the microgroove in a 3D microchannel. We used computational fluid dynamics to analyze the fluid recirculation area inside different microgrooves. The height of recirculation area in the bottom of microgroove could affect the cell’s attachment, and also materials delivery to attached cells, so the height of recirculation area may have optimum value. In addition, we analyzed the fluid drag force on cell movement toward the microgroove. This parameter was proportional to the fluid velocities in [Formula: see text] and [Formula: see text] directions in different microgrooves geometries. In different microgrooves’ geometries the fluid velocity in [Formula: see text]-direction did not change, but the fluid velocity in [Formula: see text]-direction decreased inside the microgroove. Therefore, the cell movement time inside the microgroove increased, and also the drag force in [Formula: see text]-direction could push the cells toward the bottom due to the lower drag force in [Formula: see text]-direction. The percentages of negative shear stress and average shear stress on the adhered cell surface were also calculated. The lower average shear stress, and negative shear stress around 50% on the cell surface were against cell detachment from the substrate. The results indicated that at the constant fluid inlet velocity and microchannel height, microgroove geometry and ratio of cell size to the microgroove size play pivotal roles in the cell initial adhesion to the substrate as well as the cell detachment.
Collapse
Affiliation(s)
- SINA AHANDOUST
- Department of Biomedical Engineering, Amirkabir University of Technology, 424 Hafez Avenue, Tehran, Iran
| | - MARYAM SAADATMAND
- Department of Chemical and Petroleum Engineering, Sharif University of Technology, Azadi Avenue, Tehran, Iran
| |
Collapse
|
37
|
Qian Y, Neale SL, Marsh JH. Microparticle manipulation using laser-induced thermophoresis and thermal convection flow. Sci Rep 2020; 10:19169. [PMID: 33154506 PMCID: PMC7644619 DOI: 10.1038/s41598-020-76209-9] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2020] [Accepted: 10/19/2020] [Indexed: 02/05/2023] Open
Abstract
We demonstrate manipulation of microbeads with diameters from 1.5 to 10 µm and Jurkat cells within a thin fluidic device using the combined effect of thermophoresis and thermal convection. The heat flow is induced by localized absorption of laser light by a cluster of single walled carbon nanotubes, with no requirement for a treated substrate. Characterization of the system shows the speed of particle motion increases with optical power absorption and is also affected by particle size and corresponding particle suspension height within the fluid. Further analysis shows that the thermophoretic mobility (DT) is thermophobic in sign and increases linearly with particle diameter, reaching a value of 8 µm2 s-1 K-1 for a 10 µm polystyrene bead.
Collapse
Affiliation(s)
- Yang Qian
- James Watt School of Engineering, University of Glasgow, Glasgow, G12 8QQ, UK
| | - Steven L Neale
- James Watt School of Engineering, University of Glasgow, Glasgow, G12 8QQ, UK
| | - John H Marsh
- James Watt School of Engineering, University of Glasgow, Glasgow, G12 8QQ, UK.
| |
Collapse
|
38
|
Srisom K, Tittabutr P, Teaumroong N, Lapwong Y, Phatthanakun R, Sirivisoot S, Kuntanawat P. New method for arbuscular mycorrhizal fungus spore separation using a microfluidic device based on manual temporary flow diversion. MYCORRHIZA 2020; 30:789-796. [PMID: 32918101 DOI: 10.1007/s00572-020-00986-4] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/05/2019] [Accepted: 08/19/2020] [Indexed: 05/11/2023]
Abstract
Arbuscular mycorrhizal fungi are beneficial components often included in biofertilizers. Studies of the biology and utilization of these fungi are key to their successful use in the biofertilizer industry. The acquisition of isolated spores is a required step in these studies; however, spore quality control and spore separation are bottlenecks. Filtered and centrifuged spores have to be hand-picked under a microscope. The conventional procedure is skill-demanding, labor-intensive, and time-consuming. Here, we developed a microfluidic device to aid manual separation of spores from a filtered and centrifuged suspension. The device is a single spore streamer equipped with a manual temporary flow diversion (MTFD) mechanism to select single spores. Users can press a switch to generate MTFD when the spore arrives at the selection site. The targeted spore flows in a stream to the collection chamber via temporary cross flow. Using the device, spore purity, the percentage of spore numbers against the total number of particles counted in the collecting chamber reached 96.62% (median, n = 10) which is greater than the spore purity obtained from the conventional method (88.89% (median, n = 10)).
Collapse
Affiliation(s)
- K Srisom
- Nanoscience and Nanotechnology Graduate Program, Faculty of Science, King Mongkut's University of Technology Thonburi, 126 Pracha Uthit Rd, Bang Mod, Thung Khru, Bangkok, 10140, Thailand
| | - P Tittabutr
- Institute of Agricultural Technology, Suranaree University of Technology, 111 University Avenue, Muang District, Nakhon Ratchasima, 30000, Thailand
| | - N Teaumroong
- Institute of Agricultural Technology, Suranaree University of Technology, 111 University Avenue, Muang District, Nakhon Ratchasima, 30000, Thailand
| | - Y Lapwong
- School of Life Science, University of Technology Sydney, PO Box 123, Broadway, Sydney, NSW, 2007, Australia
| | - R Phatthanakun
- Synchrotron Light Research Institute, 111 University Avenue, Muang District, Nakhon Ratchasima, 30000, Thailand
| | - S Sirivisoot
- Nanoscience and Nanotechnology Graduate Program, Faculty of Science, King Mongkut's University of Technology Thonburi, 126 Pracha Uthit Rd, Bang Mod, Thung Khru, Bangkok, 10140, Thailand
| | - P Kuntanawat
- Institute of Agricultural Technology, Suranaree University of Technology, 111 University Avenue, Muang District, Nakhon Ratchasima, 30000, Thailand.
| |
Collapse
|
39
|
Syed MS, Mirakhorli F, Marquis C, Taylor RA, Warkiani ME. Particle movement and fluid behavior visualization using an optically transparent 3D-printed micro-hydrocyclone. BIOMICROFLUIDICS 2020; 14:064106. [PMID: 33269035 PMCID: PMC7679180 DOI: 10.1063/5.0025391] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/20/2020] [Accepted: 11/04/2020] [Indexed: 05/03/2023]
Abstract
A hydrocyclone is a macroscale separation device employed in various industries, with many advantages, including high-throughput and low operational costs. Translating these advantages to microscale has been a challenge due to the microscale fabrication limitations that can be surmounted using 3D printing technology. Additionally, it is difficult to simulate the performance of real 3D-printed micro-hydrocyclones because of turbulent eddies and the deviations from the design due to printing resolution. To address these issues, we propose a new experimental method for the direct observation of particle motion in 3D printed micro-hydrocyclones. To do so, wax 3D printing and soft lithography were used in combination to construct a transparent micro-hydrocyclone in a single block of polydimethylsiloxane. A high-speed camera and fluorescent particles were employed to obtain clear in situ images and to confirm the presence of the vortex core. To showcase the use of this method, we demonstrate that a well-designed device can achieve a 95% separation efficiency for a sample containing a mixture of (desired) stem cells and (undesired) microcarriers. Overall, we hope that the proposed method for the direct visualization of particle trajectories in micro-hydrocyclones will serve as a tool, which can be leveraged to accelerate the development of micro-hydrocyclones for biomedical applications.
Collapse
Affiliation(s)
- Maira Shakeel Syed
- School of Mechanical and Manufacturing Engineering, University of New South Wales, Sydney, NSW 2052, Australia
| | - Fateme Mirakhorli
- School of Biomedical Engineering, University of Technology Sydney, NSW 2007, Australia
| | - Christopher Marquis
- School of Biotechnology and Biomolecular Science, University of New South Wales, Sydney, NSW 2052, Australia
| | | | | |
Collapse
|
40
|
Mossige EJ, Jensen A. Clog-Free Trilobite Filtration: Tunable Flow Setup and Velocity Measurements. MICROMACHINES 2020; 11:mi11100904. [PMID: 33003618 PMCID: PMC7600505 DOI: 10.3390/mi11100904] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/20/2020] [Revised: 09/24/2020] [Accepted: 09/25/2020] [Indexed: 11/16/2022]
Abstract
The ability to separate and filter out microscopic objects lies at the core of many biomedical applications. However, a persistent problem is clogging, as biomaterials stick to the internal chip surface and limit device efficiency and liability. Here, we review an alternative technique that could solve these clogging issues. By leveraging tunable flow fields and particle inertia around special trilobite-shaped filtration units, we perform filtration of plastic beads by size and we demonstrate sorting of live cells. The separation and filtration are performed completely without signs of clogging. However, a clog-free operation relies on a controlled flow configuration to steer the particles and cells away from the filter structures. In this paper, we describe the tunable flow system for such an operation and we describe an optical setup enabling hydrodynamical interactions between particles and cells with the flow fields and direct interactions with the filter structures to be characterized. The optical setup is capable of measuring particle and flow velocities (by Particle Tracking Velocimetry (PTV), Micro Particle Image Velocimetry (μPIV), and streakline visualization) in meters per second necessary to avoid clogging. However, accurate measurements rely on strict calibration and validation procedures to be followed, and we devote a substantial portion of our paper to laying out such procedures. A comparison between μPIV data and a known flow profile is particularly valuable for assessing measurement accuracy, and this important validation has not been previously published by us. The detail level in our description of the flow configuration and optical system is sufficient to replicate the experiments. In the last part of the paper, we review an assessment of the device performance when handling rigid spheres and live cells. We deconvolute the influences of cell shape from effects of size and find that the shape has only a weak influence on device performance.
Collapse
|
41
|
Sun L, Yang W, Cai S, Chen Y, Chu H, Yu H, Wang Y, Liu L. Recent advances in microfluidic technologies for separation of biological cells. Biomed Microdevices 2020; 22:55. [PMID: 32797312 DOI: 10.1007/s10544-020-00510-7] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Cell separation has always been a key topic in academic research, especially in the fields of medicine and biology, due to its significance in diagnosis and treatment. Accurate, high-throughput and non-invasive separation of individual cells is key to driving the development of biomedicine and cellular biology. In recent years, a series of researches on the use of microfluidic technologies for cell separation have been conducted to solve bio-related problems. Hence, we present here a comprehensive review on the recent developments of microfluidic technologies for cell separation. In this review, we discuss several cell separation methods, mainly including: physical and biochemical method, their working principles as well as their practical applications. We also analyze the advantages and disadvantages of each method in detail. In addition, the current challenges and future prospects of microfluidic-based cell separation were discussed.
Collapse
Affiliation(s)
- Lujing Sun
- School of Electromechanical and Automotive Engineering, Yantai University, Yantai, 264005, China
| | - Wenguang Yang
- School of Electromechanical and Automotive Engineering, Yantai University, Yantai, 264005, China.
| | - Shuxiang Cai
- School of Electromechanical and Automotive Engineering, Yantai University, Yantai, 264005, China
| | - Yibao Chen
- School of Electromechanical and Automotive Engineering, Yantai University, Yantai, 264005, China
| | - Honghui Chu
- School of Electromechanical and Automotive Engineering, Yantai University, Yantai, 264005, China
| | - Haibo Yu
- State Key Laboratory of Robotics, Shenyang Institute of Automation, Chinese Academy of Sciences, Shenyang, 110016, China
- Institutes for Robotics and Intelligent Manufacturing, Chinese Academy of Sciences, Shenyang, 110016, China
| | - Yuechao Wang
- State Key Laboratory of Robotics, Shenyang Institute of Automation, Chinese Academy of Sciences, Shenyang, 110016, China
- Institutes for Robotics and Intelligent Manufacturing, Chinese Academy of Sciences, Shenyang, 110016, China
| | - Lianqing Liu
- State Key Laboratory of Robotics, Shenyang Institute of Automation, Chinese Academy of Sciences, Shenyang, 110016, China.
- Institutes for Robotics and Intelligent Manufacturing, Chinese Academy of Sciences, Shenyang, 110016, China.
| |
Collapse
|
42
|
Nasiri R, Shamloo A, Akbari J, Tebon P, R. Dokmeci M, Ahadian S. Design and Simulation of an Integrated Centrifugal Microfluidic Device for CTCs Separation and Cell Lysis. MICROMACHINES 2020; 11:E699. [PMID: 32698447 PMCID: PMC7407509 DOI: 10.3390/mi11070699] [Citation(s) in RCA: 24] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/14/2020] [Revised: 07/10/2020] [Accepted: 07/15/2020] [Indexed: 01/02/2023]
Abstract
Separation of circulating tumor cells (CTCs) from blood samples and subsequent DNA extraction from these cells play a crucial role in cancer research and drug discovery. Microfluidics is a versatile technology that has been applied to create niche solutions to biomedical applications, such as cell separation and mixing, droplet generation, bioprinting, and organs on a chip. Centrifugal microfluidic biochips created on compact disks show great potential in processing biological samples for point of care diagnostics. This study investigates the design and numerical simulation of an integrated microfluidic device, including a cell separation unit for isolating CTCs from a blood sample and a micromixer unit for cell lysis on a rotating disk platform. For this purpose, an inertial microfluidic device was designed for the separation of target cells by using contraction-expansion microchannel arrays. Additionally, a micromixer was incorporated to mix separated target cells with the cell lysis chemical reagent to dissolve their membranes to facilitate further assays. Our numerical simulation approach was validated for both cell separation and micromixer units and corroborates existing experimental results. In the first compartment of the proposed device (cell separation unit), several simulations were performed at different angular velocities from 500 rpm to 3000 rpm to find the optimum angular velocity for maximum separation efficiency. By using the proposed inertial separation approach, CTCs, were successfully separated from white blood cells (WBCs) with high efficiency (~90%) at an angular velocity of 2000 rpm. Furthermore, a serpentine channel with rectangular obstacles was designed to achieve a highly efficient micromixer unit with high mixing quality (~98%) for isolated CTCs lysis at 2000 rpm.
Collapse
Affiliation(s)
- Rohollah Nasiri
- Department of Mechanical Engineering, Sharif University of Technology, Tehran 11365-11155, Iran; (R.N.); (J.A.)
- Center for Minimally Invasive Therapeutics (C-MIT), University of California—Los Angeles, Los Angeles, CA 90095, USA; (P.T.); (M.R.D.)
- Department of Bioengineering, University of California—Los Angeles, Los Angeles, CA 90095, USA
| | - Amir Shamloo
- Department of Mechanical Engineering, Sharif University of Technology, Tehran 11365-11155, Iran; (R.N.); (J.A.)
| | - Javad Akbari
- Department of Mechanical Engineering, Sharif University of Technology, Tehran 11365-11155, Iran; (R.N.); (J.A.)
| | - Peyton Tebon
- Center for Minimally Invasive Therapeutics (C-MIT), University of California—Los Angeles, Los Angeles, CA 90095, USA; (P.T.); (M.R.D.)
- Department of Bioengineering, University of California—Los Angeles, Los Angeles, CA 90095, USA
| | - Mehmet R. Dokmeci
- Center for Minimally Invasive Therapeutics (C-MIT), University of California—Los Angeles, Los Angeles, CA 90095, USA; (P.T.); (M.R.D.)
- Department of Bioengineering, University of California—Los Angeles, Los Angeles, CA 90095, USA
- Department of Radiological Sciences, David Geffen School of Medicine, University of California-Los Angeles, Los Angeles, CA 90095, USA
| | - Samad Ahadian
- Center for Minimally Invasive Therapeutics (C-MIT), University of California—Los Angeles, Los Angeles, CA 90095, USA; (P.T.); (M.R.D.)
- Department of Bioengineering, University of California—Los Angeles, Los Angeles, CA 90095, USA
| |
Collapse
|
43
|
Jammes FC, Maerkl SJ. How single-cell immunology is benefiting from microfluidic technologies. MICROSYSTEMS & NANOENGINEERING 2020; 6:45. [PMID: 34567657 PMCID: PMC8433390 DOI: 10.1038/s41378-020-0140-8] [Citation(s) in RCA: 29] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/22/2019] [Revised: 01/14/2020] [Accepted: 01/25/2020] [Indexed: 05/03/2023]
Abstract
The immune system is a complex network of specialized cells that work in concert to protect against invading pathogens and tissue damage. Imbalances in this network often result in excessive or absent immune responses leading to allergies, autoimmune diseases, and cancer. Many of the mechanisms and their regulation remain poorly understood. Immune cells are highly diverse, and an immune response is the result of a large number of molecular and cellular interactions both in time and space. Conventional bulk methods are often prone to miss important details by returning population-averaged results. There is a need in immunology to measure single cells and to study the dynamic interplay of immune cells with their environment. Advances in the fields of microsystems and microengineering gave rise to the field of microfluidics and its application to biology. Microfluidic systems enable the precise control of small volumes in the femto- to nanoliter range. By controlling device geometries, surface chemistry, and flow behavior, microfluidics can create a precisely defined microenvironment for single-cell studies with spatio-temporal control. These features are highly desirable for single-cell analysis and have made microfluidic devices useful tools for studying complex immune systems. In addition, microfluidic devices can achieve high-throughput measurements, enabling in-depth studies of complex systems. Microfluidics has been used in a large panel of biological applications, ranging from single-cell genomics, cell signaling and dynamics to cell-cell interaction and cell migration studies. In this review, we give an overview of state-of-the-art microfluidic techniques, their application to single-cell immunology, their advantages and drawbacks, and provide an outlook for the future of single-cell technologies in research and medicine.
Collapse
Affiliation(s)
- Fabien C. Jammes
- Institute of Bioengineering, School of Engineering, École Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
| | - Sebastian J. Maerkl
- Institute of Bioengineering, School of Engineering, École Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
| |
Collapse
|
44
|
Nasiri R, Shamloo A, Ahadian S, Amirifar L, Akbari J, Goudie MJ, Lee K, Ashammakhi N, Dokmeci MR, Di Carlo D, Khademhosseini A. Microfluidic-Based Approaches in Targeted Cell/Particle Separation Based on Physical Properties: Fundamentals and Applications. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2020; 16:e2000171. [PMID: 32529791 DOI: 10.1002/smll.202000171] [Citation(s) in RCA: 89] [Impact Index Per Article: 22.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/10/2020] [Revised: 03/15/2020] [Indexed: 06/11/2023]
Abstract
Cell separation is a key step in many biomedical research areas including biotechnology, cancer research, regenerative medicine, and drug discovery. While conventional cell sorting approaches have led to high-efficiency sorting by exploiting the cell's specific properties, microfluidics has shown great promise in cell separation by exploiting different physical principles and using different properties of the cells. In particular, label-free cell separation techniques are highly recommended to minimize cell damage and avoid costly and labor-intensive steps of labeling molecular signatures of cells. In general, microfluidic-based cell sorting approaches can separate cells using "intrinsic" (e.g., fluid dynamic forces) versus "extrinsic" external forces (e.g., magnetic, electric field, etc.) and by using different properties of cells including size, density, deformability, shape, as well as electrical, magnetic, and compressibility/acoustic properties to select target cells from a heterogeneous cell population. In this work, principles and applications of the most commonly used label-free microfluidic-based cell separation methods are described. In particular, applications of microfluidic methods for the separation of circulating tumor cells, blood cells, immune cells, stem cells, and other biological cells are summarized. Computational approaches complementing such microfluidic methods are also explained. Finally, challenges and perspectives to further develop microfluidic-based cell separation methods are discussed.
Collapse
Affiliation(s)
- Rohollah Nasiri
- Center for Minimally Invasive Therapeutics (C-MIT), University of California, Los Angeles, Los Angeles, CA, 90095, USA
- Department of Bioengineering, University of California, Los Angeles, Los Angeles, CA, 90095, USA
- Department of Mechanical Engineering, Sharif University of Technology, Tehran, 11365-11155, Iran
| | - Amir Shamloo
- Department of Mechanical Engineering, Sharif University of Technology, Tehran, 11365-11155, Iran
| | - Samad Ahadian
- Center for Minimally Invasive Therapeutics (C-MIT), University of California, Los Angeles, Los Angeles, CA, 90095, USA
- Department of Bioengineering, University of California, Los Angeles, Los Angeles, CA, 90095, USA
- Terasaki Institute for Biomedical Innovation (TIBI), Los Angeles, CA, 90024, USA
| | - Leyla Amirifar
- Department of Mechanical Engineering, Sharif University of Technology, Tehran, 11365-11155, Iran
| | - Javad Akbari
- Department of Mechanical Engineering, Sharif University of Technology, Tehran, 11365-11155, Iran
| | - Marcus J Goudie
- Center for Minimally Invasive Therapeutics (C-MIT), University of California, Los Angeles, Los Angeles, CA, 90095, USA
- Department of Bioengineering, University of California, Los Angeles, Los Angeles, CA, 90095, USA
| | - KangJu Lee
- Center for Minimally Invasive Therapeutics (C-MIT), University of California, Los Angeles, Los Angeles, CA, 90095, USA
- Department of Bioengineering, University of California, Los Angeles, Los Angeles, CA, 90095, USA
| | - Nureddin Ashammakhi
- Center for Minimally Invasive Therapeutics (C-MIT), University of California, Los Angeles, Los Angeles, CA, 90095, USA
- Department of Bioengineering, University of California, Los Angeles, Los Angeles, CA, 90095, USA
- Department of Radiological Sciences, University of California, Los Angeles, Los Angeles, CA, 90095, USA
| | - Mehmet R Dokmeci
- Center for Minimally Invasive Therapeutics (C-MIT), University of California, Los Angeles, Los Angeles, CA, 90095, USA
- Department of Bioengineering, University of California, Los Angeles, Los Angeles, CA, 90095, USA
- Terasaki Institute for Biomedical Innovation (TIBI), Los Angeles, CA, 90024, USA
- Department of Radiological Sciences, University of California, Los Angeles, Los Angeles, CA, 90095, USA
| | - Dino Di Carlo
- Department of Bioengineering, University of California, Los Angeles, Los Angeles, CA, 90095, USA
| | - Ali Khademhosseini
- Center for Minimally Invasive Therapeutics (C-MIT), University of California, Los Angeles, Los Angeles, CA, 90095, USA
- Department of Bioengineering, University of California, Los Angeles, Los Angeles, CA, 90095, USA
- Terasaki Institute for Biomedical Innovation (TIBI), Los Angeles, CA, 90024, USA
- Department of Radiological Sciences, University of California, Los Angeles, Los Angeles, CA, 90095, USA
- Department of Chemical and Biomolecular Engineering, University of California, Los Angeles, Los Angeles, CA, 90095, USA
| |
Collapse
|
45
|
Zhang Y, Wang S, Chen J, Yang F, Li G. Separation of Macrophages Using a Dielectrophoresis-Based Microfluidic Device. BIOCHIP JOURNAL 2020. [DOI: 10.1007/s13206-020-4207-2] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
46
|
Zahedi Siani O, Zabetian Targhi M, Sojoodi M, Movahedin M. Dielectrophoretic separation of monocytes from cancer cells in a microfluidic chip using electrode pitch optimization. Bioprocess Biosyst Eng 2020; 43:1573-1586. [PMID: 32328730 DOI: 10.1007/s00449-020-02349-x] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2019] [Accepted: 04/06/2020] [Indexed: 12/11/2022]
Abstract
This study proposes a microfluidic device capable of separating monocytes from a type of cancer cell that is called T-cell acute lymphoblastic leukemia (RPMI-8402) in a continuous flow using negative and positive dielectrophoretic forces. The use of both the hydrodynamic and dielectrophoretic forces allows the separation of RPMI-8402 from monocytes based on differences in their intrinsic electrical properties and sizes. The specific crossover frequencies of monocytes and RPMI-8402 cells have been obtained experimentally. The optimum ranges of electrode pitch-to-channel height ratio at the cross sections with different electrode widths have been generally calculated by numerical simulations of the gradients of the electric field intensities and calculation their effective values (root-mean-square). In the device, the cell sorting has been conducted empirically, and then, the separation performance has been evaluated by analyzing the images before and after dielectrophoretic forces applied to the cells. In this work, the design of a chip with 77 μm gold-titanium electrode pitch was investigated to achieve high purity of monocytes of 95.2%. The proposed device can be used with relatively low applied voltages, as low as 16.5 V (peak to peak). Thus, the design can be used in biomedical diagnosis and chemical analysis applications as a lab-on-chip platform. Also, it can be used for the separation of biological cells such as bacteria, RNA, DNA, and blood cells.
Collapse
Affiliation(s)
- Omid Zahedi Siani
- Faculty of Mechanical Engineering, Tarbiat Modares University, Tehran, Iran
| | | | - Mahdi Sojoodi
- Faculty of Electrical and Computer Engineering, Tarbiat Modares University, Tehran, Iran
| | | |
Collapse
|
47
|
Xiang N, Li Q, Ni Z. Combining Inertial Microfluidics with Cross-Flow Filtration for High-Fold and High-Throughput Passive Volume Reduction. Anal Chem 2020; 92:6770-6776. [PMID: 32297510 DOI: 10.1021/acs.analchem.0c01006] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
We reporte a three-stage spiral channel device for achieving high-fold and high-throughput passive volume reduction through coupling inertial microfluidics with cross-flow filtration. To understand the device physics and optimize the structure, the effects of critical channel design on particle dynamics and volume reduction performance were explored. Then the principle of volume reduction was used for concentrating cells from large-volume fluids, and the concentration performance of differently sized particles/cells in the determined device was quantitatively characterized over wide flow rates. The results indicated that our device could achieve high-efficiency cell concentration at a high throughput of over 4 mL/min. Finally, we successfully applied our device for the enrichment of rare tumor cells after being separated from the blood or peritoneal fluid and the extremely high fold concentration of white blood cells from the large-volume fluid. Using a serial concentration, an ultrahigh concentration fold of approximately 1100 could be achieved. Our device offers numerous advantages, such as high-processing throughput, high concentration fold, simple channel design, and low-cost fabrication. Thus, it holds the potential to be used as a sample concentration tool for disposable use in low-resource settings.
Collapse
Affiliation(s)
- Nan Xiang
- School of Mechanical Engineering and Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University, Nanjing 211189, China
| | - Qiao Li
- School of Mechanical Engineering and Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University, Nanjing 211189, China
| | - Zhonghua Ni
- School of Mechanical Engineering and Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University, Nanjing 211189, China
| |
Collapse
|
48
|
Hydrophoresis — A Microfluidic Principle for Directed Particle Migration in Flow. BIOCHIP JOURNAL 2020. [DOI: 10.1007/s13206-020-4107-5] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
|
49
|
Evaluation of Performance and Tunability of a Co-Flow Inertial Microfluidic Device. MICROMACHINES 2020; 11:mi11030287. [PMID: 32164264 PMCID: PMC7142704 DOI: 10.3390/mi11030287] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/28/2020] [Revised: 02/28/2020] [Accepted: 03/05/2020] [Indexed: 02/08/2023]
Abstract
Microfluidics has gained a lot of attention for biological sample separation and purification methods over recent years. From many active and passive microfluidic techniques, inertial microfluidics offers a simple and efficient method to demonstrate various biological applications. One prevalent limitation of this method is its lack of tunability for different applications once the microfluidic devices are fabricated. In this work, we develop and characterize a co-flow inertial microfluidic device that is tunable in multiple ways for adaptation to different application requirements. In particular, flow rate, flow rate ratio and output resistance ratio are systematically evaluated for flexibility of the cutoff size of the device and modification of the separation performance post-fabrication. Typically, a mixture of single size particles is used to determine cutoff sizes for the outlets, yet this fails to provide accurate prediction for efficiency and purity for a more complex biological sample. Thus, we use particles with continuous size distribution (2–32 μm) for separation demonstration under conditions of various flow rates, flow rate ratios and resistance ratios. We also use A549 cancer cell line with continuous size distribution (12–27 μm) as an added demonstration. Our results indicate inertial microfluidic devices possess the tunability that offers multiple ways to improve device performance for adaptation to different applications even after the devices are prototyped.
Collapse
|
50
|
Yoon K, Jung HW, Chun MS. Two-phase flow in microfluidic-chip design of hydrodynamic filtration for cell particle sorting. Electrophoresis 2020; 41:1002-1010. [PMID: 32097495 DOI: 10.1002/elps.201900394] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2019] [Revised: 02/21/2020] [Accepted: 02/21/2020] [Indexed: 11/07/2022]
Abstract
As one of the flow-based passive sorting, the hydrodynamic filtration using a microfluidic-chip has shown to effectively separate into different sizes of subpopulations from cell or particle suspensions. Its model framework involving two-phase Newtonian or generalized Newtonian fluid (GNF) was developed, by performing the complete analysis of laminar flow and complicated networks of main and multiple branch channels. To predict rigorously what occurs in flow fields, we estimated pressure drop, velocity profile, and the ratio of the flow fraction at each branch point, in which the analytical model was validated with numerical flow simulations. As a model fluid of the GNF, polysaccharide solution based on Carreau type was examined. The objective parameters aiming practical channel design include the number of the branches and the length of narrow section of each branch for arbitrary conditions. The flow fraction and the number of branches are distinctly affected by the viscosity ratio between feed and side flows. As the side flow becomes more viscous, the flow fraction increases but the number of branches decreases, which enables a compact chip designed with fewer branches being operated under the same throughput. Hence, our rational design analysis indicates the significance of constitutive properties of each stream.
Collapse
Affiliation(s)
- Kyu Yoon
- Department of Chemical and Biological Engineering, Korea University, Seongbuk-gu, Seoul, Republic of Korea.,National Agenda Research Division, Korea Institute of Science and Technology (KIST), Seoul, Republic of Korea
| | - Hyun Wook Jung
- Department of Chemical and Biological Engineering, Korea University, Seongbuk-gu, Seoul, Republic of Korea
| | - Myung-Suk Chun
- National Agenda Research Division, Korea Institute of Science and Technology (KIST), Seoul, Republic of Korea.,Bio-Medical Department, KIST School, Korea University of Science and Technology, Seoul, Republic of Korea
| |
Collapse
|