1
|
Derakhshan R, Bozorgzadeh A, Ramiar A. Numerical investigation of ternary particle separation in a microchannel with a wall-mounted obstacle using dielectrophoresis. J Chromatogr A 2023; 1702:464079. [PMID: 37263054 DOI: 10.1016/j.chroma.2023.464079] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2023] [Revised: 05/09/2023] [Accepted: 05/16/2023] [Indexed: 06/03/2023]
Abstract
In recent years, microfluidic-based particle/cell manipulation techniques have catalyzed significant advances in several fields of science. As an efficient, precise, and label-free particle/cell manipulation technique, dielectrophoresis (DEP) has recently attracted widespread attention. This paper presents the design and investigation of a straight sheathless 3D microchannel with a wall-mounted trapezoidal obstacle for continuous-flow separation of three different populations of polystyrene (PS) particles (5, 10 and 20 µm) using DEP. An OpenFOAM code is developed to simulate and investigate the movement of particles in the microchannel. Then, the code is validated by performing various experimental tests using a microdevice previously fabricated in our lab. By comparing the numerical simulation results with the experimental tests, it can be claimed that the newly developed solver is highly accurate, and its results agree well with experimental tests. Next, the effect of various operational and geometrical parameters such as obstacle height, applied voltage, electrode pairs angle, and flow rate on the efficient focusing and separation of particles are numerically investigated. The results showed that efficient particle separation could only be achieved for obstacle heights of more than 350 µm. Furthermore, the appropriate voltage range for efficient particle separation is increased by decreasing the electrode angle as well as increasing the flow rate. Moreover, the results showed that by employing the appropriate channel design and operational conditions, at a maximum applied voltage of 10V, a sample flow rate of 2.5μL/min could be processed. The proposed design can be beneficial for integrating with lab-on-a-chip and clinical diagnosis applications due to advantages, such as simple design, no need for sheath flow, the simultaneous ternary separation of particles, and providing precise particle separation.
Collapse
Affiliation(s)
- Reza Derakhshan
- Mechanical Engineering Department, Microfluidics and MEMS lab, Babol Noshirvani University of Technology, Babol, Mazandaran, Iran.
| | - Ali Bozorgzadeh
- Mechanical Engineering Department, Microfluidics and MEMS lab, Babol Noshirvani University of Technology, Babol, Mazandaran, Iran.
| | - Abas Ramiar
- Mechanical Engineering Department, Microfluidics and MEMS lab, Babol Noshirvani University of Technology, Babol, Mazandaran, Iran.
| |
Collapse
|
2
|
Sharbati P, Sadaghiani AK, Koşar A. New Generation Dielectrophoretic-Based Microfluidic Device for Multi-Type Cell Separation. BIOSENSORS 2023; 13:bios13040418. [PMID: 37185493 PMCID: PMC10135750 DOI: 10.3390/bios13040418] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/10/2023] [Revised: 03/11/2023] [Accepted: 03/22/2023] [Indexed: 05/17/2023]
Abstract
This study introduces a new generation of dielectrophoretic-based microfluidic device for the precise separation of multiple particle/cell types. The device features two sets of 3D electrodes, namely cylindrical and sidewall electrodes. The main channel of the device terminates with three outlets: one in the middle for particles that sense negative dielectrophoresis force and two others at the right and left sides for particles that sense positive dielectrophoresis force. To evaluate the device performance, we used red blood cells (RBCs), T-cells, U937-MC cells, and Clostridium difficile bacteria as our test subjects. Our results demonstrate that the proposed microfluidic device could accurately separate bioparticles in two steps, with sidewall electrodes of 200 µm proving optimal for efficient separation. Applying different voltages for each separation step, we found that the device performed most effectively at 6 Vp-p applied to the 3D electrodes, and at 20 Vp-p and 11 Vp-p applied to the sidewall electrodes for separating RBCs from bacteria and T-cells from U937-MC cells, respectively. Notably, the device's maximum electric fields remained below the cell electroporation threshold, and we achieved a separation efficiency of 95.5% for multi-type particle separation. Our findings proved the device's capacity for separating multiple particle types with high accuracy, without limitation for particle variety.
Collapse
Affiliation(s)
- Pouya Sharbati
- Faculty of Engineering and Natural Sciences, Sabanci University, Istanbul 34956, Turkey
- Sabanci University Nanotechnology and Applications Center (SUNUM), Sabanci University, Istanbul 34956, Turkey
| | - Abdolali K Sadaghiani
- Faculty of Engineering and Natural Sciences, Sabanci University, Istanbul 34956, Turkey
- Sabanci University Nanotechnology and Applications Center (SUNUM), Sabanci University, Istanbul 34956, Turkey
| | - Ali Koşar
- Faculty of Engineering and Natural Sciences, Sabanci University, Istanbul 34956, Turkey
- Sabanci University Nanotechnology and Applications Center (SUNUM), Sabanci University, Istanbul 34956, Turkey
| |
Collapse
|
3
|
Huang C, Han SI, Zhang H, Han A. Tutorial on Lateral Dielectrophoretic Manipulations in Microfluidic Systems. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2023; 17:21-32. [PMID: 37015136 PMCID: PMC10091972 DOI: 10.1109/tbcas.2022.3226675] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
Microfluidic lab-on-a-chip systems can offer cost- and time-efficient biological assays by providing high-throughput analysis at very small volume scale. Among these extremely broad ranges of assays, accurate and specific cell and reagent control is considered one of the most important functions. Dielectrophoretic (DEP)-based manipulation technologies have been extensively developed for these purposes due to their label-free and high selectivity natures as well as due to their simple microstructures. Here, we provide a tutorial on how to develop DEP-based microfluidic systems, including a detailed walkthrough of dielectrophoresis theory, instruction on how to conduct simulation and calculation of electric field and generated DEP force, followed with guidance on microfabricating two forms of DEP microfluidic systems, namely lateral DEP and droplet DEP, and how best to conduct experiments in such systems. Finally, we summarize most recent DEP-based microfluidic technologies and applications, including systems for blood diagnoses, pathogenicity studies, in-droplet content manipulations, droplet manipulations and merging, to name a few. We conclude by suggesting possible future directions on how DEP-based technologies can be utilized to overcome current challenges and improve the current status in microfluidic lab-on-a-chip systems.
Collapse
|
4
|
Emmerich MEP, Sinnigen AS, Neubauer P, Birkholz M. Dielectrophoretic separation of blood cells. Biomed Microdevices 2022; 24:30. [PMID: 36006519 PMCID: PMC9411249 DOI: 10.1007/s10544-022-00623-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 06/07/2022] [Indexed: 11/02/2022]
Abstract
Microfluidic dielectrophoretic (DEP) devices enable the label-free separation and isolation of cells based on differences in their electrophysiological properties. The technique can serve as a tool in clinical diagnostics and medical research as it facilitates the analysis of patient-specific blood composition and the detection and isolation of pathogenic cells like circulating tumor cells or malaria-infected erythrocytes. This review compares different microfluidic DEP devices to separate platelets, erythrocytes and leukocytes including their cellular subclasses. An overview and experimental setups of different microfluidic DEP devices for the separation, trapping and isolation or purification of blood cells are detailed with respect to their technical design, electrode configuration, sample preparation, applied voltage and frequency and created DEP field based and related to the separation efficiency. The technique holds the promise that results can quickly be attained in clinical and ambulant settings. In particular, point-of-care-testing scenarios are favored by the extensive miniaturization, which would be enabled by microelectronical integration of DEP devices.
Collapse
Affiliation(s)
- Maria E. P. Emmerich
- Chair of Bioprocess Engineering, Institute of Biotechnology, TU Berlin, Ackerstrasse 76, ACK24, D-13355 Berlin, Germany
- IHP – Leibniz-Institut für innovative Mikroelektronik, Im Technologiepark 25, 15236 Frankfurt (Oder), Germany
| | - Anne-Sophie Sinnigen
- Chair of Bioprocess Engineering, Institute of Biotechnology, TU Berlin, Ackerstrasse 76, ACK24, D-13355 Berlin, Germany
| | - Peter Neubauer
- Chair of Bioprocess Engineering, Institute of Biotechnology, TU Berlin, Ackerstrasse 76, ACK24, D-13355 Berlin, Germany
| | - Mario Birkholz
- IHP – Leibniz-Institut für innovative Mikroelektronik, Im Technologiepark 25, 15236 Frankfurt (Oder), Germany
| |
Collapse
|
5
|
Inertia-Acoustophoresis Hybrid Microfluidic Device for Rapid and Efficient Cell Separation. SENSORS 2022; 22:s22134709. [PMID: 35808206 PMCID: PMC9268962 DOI: 10.3390/s22134709] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/16/2022] [Revised: 06/18/2022] [Accepted: 06/20/2022] [Indexed: 01/07/2023]
Abstract
In this paper, we proposed an integrated microfluidic device that could demonstrate the non-contact, label-free separation of particles and cells through the combination of inertial microfluidics and acoustophoresis. The proposed device integrated two microfluidic chips which were a PDMS channel chip on top of the silicon-based acoustofluidic chip. The PDMS chip worked by prefocusing the particles/cells through inducing the inertial force of the channel structure. The connected acoustofluidic chips separated particles based on their size through an acoustic radiation force. In the serpentine-shaped PDMS chip, particles formed two lines focusing in the channel, and a trifugal-shaped acoustofluidic chip displaced and separated particles, in which larger particles focused on the central channel and smaller ones moved to the side channels. The simultaneous fluidic works allowed high-efficiency particle separation. Using this novel acoustofluidic device with an inertial microchannel, the separation of particles and cells based on their size was presented and analyzed, and the efficiency of the device was shown. The device demonstrated excellent separation performance with a high recovery ratio (up to 96.3%), separation efficiency (up to 99%), and high volume rate (>100 µL/min). Our results showed that integrated devices could be a viable alternative to current cell separation based on their low cost, reduced sample consumption and high throughput capability.
Collapse
|
6
|
Chen T, Huang C, Wang Y, Wu J. Microfluidic methods for cell separation and subsequent analysis. CHINESE CHEM LETT 2022. [DOI: 10.1016/j.cclet.2021.07.067] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
|
7
|
Derakhshan R, Ramiar A, Ghasemi A. Continuous size-based DEP separation of particles using a bi-gap electrode pair. Analyst 2022; 147:5395-5408. [DOI: 10.1039/d2an01308h] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
The design, fabrication, and characterization of an advanced microfluidic device containing a bi-gap electrode pair for the continuous separation of three different populations of particles based on their size using DEP are presented.
Collapse
Affiliation(s)
- Reza Derakhshan
- PhD Student, Mechanical Engineering Department, Microfluidics and MEMS lab, Babol Noshirvani University of Technology, Babol, Iran
| | - Abas Ramiar
- Associate professor, Faculty of Mechanical Engineering, Microfluidics and MEMS lab, Babol Noshirvani University of Technology, Babol, Iran
| | - Amirhosein Ghasemi
- PhD, Mechanical Engineering Department, Microfluidics and MEMS lab, Babol Noshirvani University of Technology, Babol, Iran
| |
Collapse
|
8
|
Dalili A, Hoorfar M. Sheath-assisted versus sheathless dielectrophoretic particle separation. Electrophoresis 2021; 42:1570-1577. [PMID: 34196426 DOI: 10.1002/elps.202100029] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2021] [Revised: 06/06/2021] [Accepted: 06/10/2021] [Indexed: 11/07/2022]
Abstract
Lab-on-chip devices are widely being used for binary and ternary cell/particle separation applications. Among the lab-on-chip methods, dielectrophoresis (DEP) is a cost-effective and label-free method, with great capabilities for size-based separation of cells and particles, which is mostly performed in sheath-assisted forms. However, the elimination of the sheath flows offers advantages such as ease of operation and higher sample throughput. In this work, we present a comparison of sheath-assisted and sheathless DEP separation of three sizes of microparticles using tilted electrodes. The sheath-assisted design was capable of separating the 5, 10, and 15 μm particles with a separation efficiency as high as 98.0% for 15 μm particles. By adding a DEP focusing region, a sheathless DEP separator was proposed, which offered higher throughputs (up to 10 times) at the cost of lowering the separation efficiency (a reduction up to 10.3% for 15 μm) compared to the sheath-assisted design. To enhance the separation efficiency, a combination of the DEP focusing accompanied by weak sheath flows from both sides was proposed. This design achieved the highest sample separation yield in the outlets (as high as 98.7% for 15 μm) with a sample throughput of more than 4.2 μL/min. This study provides insights into the choice of an appropriate platform for any application in which the yield, purity, throughput, and portability must be considered.
Collapse
Affiliation(s)
- Arash Dalili
- School of Engineering, Faculty of Applied Science, The University of British Columbia, Kelowna, BC, Canada
| | - Mina Hoorfar
- School of Engineering, Faculty of Applied Science, The University of British Columbia, Kelowna, BC, Canada
| |
Collapse
|
9
|
Kwizera EA, Sun M, White AM, Li J, He X. Methods of Generating Dielectrophoretic Force for Microfluidic Manipulation of Bioparticles. ACS Biomater Sci Eng 2021; 7:2043-2063. [PMID: 33871975 PMCID: PMC8205986 DOI: 10.1021/acsbiomaterials.1c00083] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Manipulation of microscale bioparticles including living cells is of great significance to the broad bioengineering and biotechnology fields. Dielectrophoresis (DEP), which is defined as the interactions between dielectric particles and the electric field, is one of the most widely used techniques for the manipulation of bioparticles including cell separation, sorting, and trapping. Bioparticles experience a DEP force if they have a different polarization from the surrounding media in an electric field that is nonuniform in terms of the intensity and/or phase of the electric field. A comprehensive literature survey shows that the DEP-based microfluidic devices for manipulating bioparticles can be categorized according to the methods of creating the nonuniformity via patterned microchannels, electrodes, and media to generate the DEP force. These methods together with the theory of DEP force generation are described in this review, to provide a summary of the methods and materials that have been used to manipulate various bioparticles for various specific biological outcomes. Further developments of DEP-based technologies include identifying materials that better integrate with electrodes than current popular materials (silicone/glass) and improving the performance of DEP manipulation of bioparticles by combining it with other methods of handling bioparticles. Collectively, DEP-based microfluidic manipulation of bioparticles holds great potential for various biomedical applications.
Collapse
Affiliation(s)
- Elyahb A. Kwizera
- Fischell Department of Bioengineering, University of Maryland, College Park, MD 20742, USA
| | - Mingrui Sun
- Department of Biomedical Engineering, The Ohio State University, Columbus, Ohio 43210, USA
| | - Alisa M. White
- Fischell Department of Bioengineering, University of Maryland, College Park, MD 20742, USA
| | - Jianrong Li
- Department of Veterinary Biosciences, The Ohio State University, Columbus, OH 43210, USA
| | - Xiaoming He
- Fischell Department of Bioengineering, University of Maryland, College Park, MD 20742, USA
- Department of Biomedical Engineering, The Ohio State University, Columbus, Ohio 43210, USA
- Robert E. Fischell Institute for Biomedical Devices, University of Maryland, College Park, MD 20742, USA
- Marlene and Stewart Greenebaum Comprehensive Cancer Center, University of Maryland, Baltimore, MD 21201, USA
| |
Collapse
|
10
|
Çağlayan Z, Demircan Yalçın Y, Külah H. A Prominent Cell Manipulation Technique in BioMEMS: Dielectrophoresis. MICROMACHINES 2020; 11:E990. [PMID: 33153069 PMCID: PMC7693018 DOI: 10.3390/mi11110990] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/30/2020] [Revised: 10/22/2020] [Accepted: 10/28/2020] [Indexed: 12/17/2022]
Abstract
BioMEMS, the biological and biomedical applications of micro-electro-mechanical systems (MEMS), has attracted considerable attention in recent years and has found widespread applications in disease detection, advanced diagnosis, therapy, drug delivery, implantable devices, and tissue engineering. One of the most essential and leading goals of the BioMEMS and biosensor technologies is to develop point-of-care (POC) testing systems to perform rapid prognostic or diagnostic tests at a patient site with high accuracy. Manipulation of particles in the analyte of interest is a vital task for POC and biosensor platforms. Dielectrophoresis (DEP), the induced movement of particles in a non-uniform electrical field due to polarization effects, is an accurate, fast, low-cost, and marker-free manipulation technique. It has been indicated as a promising method to characterize, isolate, transport, and trap various particles. The aim of this review is to provide fundamental theory and principles of DEP technique, to explain its importance for the BioMEMS and biosensor fields with detailed references to readers, and to identify and exemplify the application areas in biosensors and POC devices. Finally, the challenges faced in DEP-based systems and the future prospects are discussed.
Collapse
Affiliation(s)
- Zeynep Çağlayan
- Department of Electrical and Electronics Engineering, Middle East Technical University, Ankara 06800, Turkey; (Z.Ç.); (Y.D.Y.)
- METU MEMS Research and Application Center, Ankara 06800, Turkey
| | - Yağmur Demircan Yalçın
- Department of Electrical and Electronics Engineering, Middle East Technical University, Ankara 06800, Turkey; (Z.Ç.); (Y.D.Y.)
- Mikro Biyosistemler Electronics Inc., Ankara 06530, Turkey
| | - Haluk Külah
- Department of Electrical and Electronics Engineering, Middle East Technical University, Ankara 06800, Turkey; (Z.Ç.); (Y.D.Y.)
- METU MEMS Research and Application Center, Ankara 06800, Turkey
- Mikro Biyosistemler Electronics Inc., Ankara 06530, Turkey
| |
Collapse
|
11
|
Dai J, Zhang H, Huang C, Chen Z, Han A. A Gel-Based Separation-Free Point-of-Care Device for Whole Blood Glucose Detection. Anal Chem 2020; 92:16122-16129. [DOI: 10.1021/acs.analchem.0c03801] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Affiliation(s)
- Jing Dai
- Department of Electrical and Computer Engineering, Texas A&M University, College Station, Texas 77843, United States
| | - Han Zhang
- Department of Electrical and Computer Engineering, Texas A&M University, College Station, Texas 77843, United States
| | - Can Huang
- Department of Electrical and Computer Engineering, Texas A&M University, College Station, Texas 77843, United States
| | - Zheyuan Chen
- Department of Electrical and Computer Engineering, Texas A&M University, College Station, Texas 77843, United States
| | - Arum Han
- Department of Electrical and Computer Engineering, Texas A&M University, College Station, Texas 77843, United States
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843, United States
- Center for Remote Health Technologies & Systems, Texas A&M University, College Station, Texas 77843 United States
| |
Collapse
|
12
|
Han SI, Huang C, Han A. In-droplet cell separation based on bipolar dielectrophoretic response to facilitate cellular droplet assays. LAB ON A CHIP 2020; 20:3832-3841. [PMID: 32926042 DOI: 10.1039/d0lc00710b] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Precise manipulation of cells within water-in-oil emulsion droplets has the potential to vastly expand the type of cellular assays that can be conducted in droplet-based microfluidics systems. However, achieving such manipulation remains challenging. Here, we present an in-droplet label-free cell separation technology by utilizing different dielectrophoretic responses of two different cell types. Two pairs of angled planar electrodes were utilized to generate positive or negative dielectrophoretic force acting on each cell type, which results in selective in-droplet movement of only one specific cell type at a time. A downstream asymmetric Y-shaped microfluidic junction splits the mother droplet into two daughter droplets, each of which contains only one cell type. The capability of this platform was successfully demonstrated by conducting in-droplet separation from a mixture of Salmonella cells and macrophages, two cell types commonly used as a bacterial pathogenicity analysis model. This technology enable the precise manipulation of cells within droplets, which can be exploited as a critical function in implementing broader ranges of droplet-based microfluidics cellular assays.
Collapse
Affiliation(s)
- Song-I Han
- Department of Electrical and Computer Engineering, Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843, USA.
| | | | | |
Collapse
|
13
|
Derakhshan R, Ramiar A, Ghasemi A. Numerical investigation into continuous separation of particles and cells in a two-component fluid flow using dielectrophoresis. J Mol Liq 2020. [DOI: 10.1016/j.molliq.2020.113211] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/16/2023]
|
14
|
Han SI, Kim HS, Han KH, Han A. Digital quantification and selection of high-lipid-producing microalgae through a lateral dielectrophoresis-based microfluidic platform. LAB ON A CHIP 2019; 19:4128-4138. [PMID: 31755503 DOI: 10.1039/c9lc00850k] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
Microalgae are promising alternatives to petroleum as renewable biofuel sources, however not sufficiently economically competitive yet. Here, a label-free lateral dielectrophoresis-based microfluidic sorting platform that can digitally quantify and separate microalgae into six outlets based on the degree of their intracellular lipid content is presented. In this microfluidic system, the degree of cellular lateral displacement is inversely proportional to the intracellular lipid level, which was successfully demonstrated using Chlamydomonas reinhardtii cells. Using this functionality, a quick digital quantification of sub-populations that contain different intracellular lipid level in a given population was achieved. In addition, the degree of lateral displacement of microalgae could be readily controlled by simply changing the applied DEP voltage, where the level of gating in the intracellular lipid-based sorting decision could be easily adjusted. This allowed for selecting only a very small percentage of a given population that showed the highest degree of intracellular lipid content. In addition, this approach was utilized through an iterative selection process on natural and chemically mutated microalgal populations, successfully resulting in enrichment of high-lipid-accumulating microalgae. In summary, the developed platform can be exploited to quickly quantify microalgae lipid distribution in a given population in real-time and label-free, as well as to enrich a cell population with high-lipid-producing cells, or to select high-lipid-accumulating microalgal variants from a microalgal library.
Collapse
Affiliation(s)
- Song-I Han
- Department of Electrical and Computer Engineering, Texas A&M University, College Station, TX 77843, USA.
| | - Hyun Soo Kim
- Korea Institute of Machinery and Materials, Daegu Research Center for Medical Devices and Rehabilitation, Daegu, 42994, Republic of Korea
| | - Ki-Ho Han
- Department of Nanoscience and Engineering, Center for Nano Manufacturing, Inje University, Gimhae, 50834, Republic of Korea
| | - Arum Han
- Department of Electrical and Computer Engineering, Texas A&M University, College Station, TX 77843, USA. and Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843, USA
| |
Collapse
|
15
|
Luo T, Fan L, Zeng Y, Liu Y, Chen S, Tan Q, Lam RHW, Sun D. A simplified sheathless cell separation approach using combined gravitational-sedimentation-based prefocusing and dielectrophoretic separation. LAB ON A CHIP 2018; 18:1521-1532. [PMID: 29725680 DOI: 10.1039/c8lc00173a] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
Prefocusing of the cell mixture is necessary for achieving a high-efficiency and continuous dielectrophoretic (DEP) cell separation. However, prefocusing through sheath flow requires a complex and tedious peripheral system for multi-channel fluid control, hindering the integration of DEP separation systems with other microfluidic functionalities for comprehensive clinical and biological tasks. This paper presented a simplified sheathless cell separation approach that combines gravitational-sedimentation-based sheathless prefocusing and DEP separation methods. Through gravitational sedimentation in a tubing, which was inserted into the inlet of a microfluidic chip with an adjustable steering angle, the cells were focused into a stream at the upstream region of a microchannel prior to separation. Then, a DEP force was applied at the downstream region of the microchannel for the active separation of the cells. Through this combined strategy, the peripheral system for the sheath flow was no longer required, and thus the integration of cell separation system with additional microfluidic functionalities was facilitated. The proposed sheathless scheme focused the mixture of cells with different sizes and dielectric properties into a stream in a wide range of flow rates without changing the design of the microfluidic chip. The DEP method is a label-free approach that can continuously separate cells on the basis of the sizes or dielectric properties of the cells and thus capable of greatly flexible cell separation. The efficiency of the proposed approach was experimentally assessed according to its performance in the separation of human acute monocytic leukemia THP-1 cells from yeast cells with respect to different sizes and THP-1 cells from human acute myelomonocytic leukemia OCI-AML3 cells with respect to different dielectric properties. The experimental results revealed that the separation efficiency of the method can surpass 90% and thus effective in separating cells on the basis of either size or dielectric property.
Collapse
Affiliation(s)
- Tao Luo
- Department of Mechanical and Biomedical Engineering, City University of Hong Kong, Hong Kong, China.
| | | | | | | | | | | | | | | |
Collapse
|
16
|
Measurement of Impedimetric Ratio of Blood Cells Using Microfluidic Chip with ZnO Nanowires. J Med Biol Eng 2017. [DOI: 10.1007/s40846-017-0333-2] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
17
|
Portable microsystem integrates multifunctional dielectrophoresis manipulations and a surface stress biosensor to detect red blood cells for hemolytic anemia. Sci Rep 2016; 6:33626. [PMID: 27647457 PMCID: PMC5028889 DOI: 10.1038/srep33626] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2016] [Accepted: 08/30/2016] [Indexed: 11/09/2022] Open
Abstract
Hemolytic anemia intensity has been suggested as a vital factor for the growth of certain clinical complications of sickle cell disease. However, there is no effective and rapid diagnostic method. As a powerful platform for bio-particles testing, biosensors integrated with microfluidics offer great potential for a new generation of portable point of care systems. In this paper, we describe a novel portable microsystem consisting of a multifunctional dielectrophoresis manipulations (MDM) device and a surface stress biosensor to separate and detect red blood cells (RBCs) for diagnosis of hemolytic anemia. The peripheral circuit to power the interdigitated electrode array of the MDM device and the surface stress biosensor test platform were integrated into a portable signal system. The MDM includes a preparing region, a focusing region, and a sorting region. Simulation and experimental results show the RBCs trajectories when they are subjected to the positive DEP force, allowing the successful sorting of living/dead RBCs. Separated RBCs are then transported to the biosensor and the capacitance values resulting from the variation of surface stress were measured. The diagnosis of hemolytic anemia can be realized by detecting RBCs and the portable microsystem provides the assessment to the hemolytic anemia patient.
Collapse
|
18
|
IIGUNI Y, TANAKA A, KITAGAWA S, OHTANI H. Staggered-electromagnetophoresis with a Split-flow System for the Separation of Microparticles by a Hollow Fiber-embedded PDMS Microchip. ANAL SCI 2016; 32:41-8. [DOI: 10.2116/analsci.32.41] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Affiliation(s)
- Yoshinori IIGUNI
- Department of Materials Science and Engineering, Graduate School of Engineering, Nagoya Institute of Technology
| | - Ayaka TANAKA
- Department of Materials Science and Engineering, Graduate School of Engineering, Nagoya Institute of Technology
| | - Shinya KITAGAWA
- Department of Materials Science and Engineering, Graduate School of Engineering, Nagoya Institute of Technology
| | - Hajime OHTANI
- Department of Materials Science and Engineering, Graduate School of Engineering, Nagoya Institute of Technology
| |
Collapse
|
19
|
Vercruysse D, Dusa A, Stahl R, Vanmeerbeeck G, de Wijs K, Liu C, Prodanov D, Peumans P, Lagae L. Three-part differential of unlabeled leukocytes with a compact lens-free imaging flow cytometer. LAB ON A CHIP 2015; 15:1123-32. [PMID: 25537881 DOI: 10.1039/c4lc01131g] [Citation(s) in RCA: 42] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
A compelling clinical need exists for inexpensive, portable haematology analyzers that can be utilized at the point-of-care in emergency settings or in resource-limited settings. Development of a label-free, microfluidic blood analysis platform is the first step towards such a miniaturized, cost-effective system. Here we assemble a compact lens-free in-line holographic microscope and employ it to image blood cells flowing in a microfluidic chip, using a high-speed camera and stroboscopic illumination. Numerical reconstruction of the captured holograms allows classification of unlabeled leukocytes into three main subtypes: lymphocytes, monocytes and granulocytes. A scale-space recognition analysis to evaluate cellular size and internal complexity is also developed and used to build a 3-part leukocyte differential. The lens-free image-based classification is compared to the 3-part white blood cell differential generated by using a conventional analyzer on the same blood sample and is found to be in good agreement with it.
Collapse
|
20
|
Dielectrophoresis for bioparticle manipulation. Int J Mol Sci 2014; 15:18281-309. [PMID: 25310652 PMCID: PMC4227216 DOI: 10.3390/ijms151018281] [Citation(s) in RCA: 91] [Impact Index Per Article: 9.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2014] [Revised: 09/18/2014] [Accepted: 09/24/2014] [Indexed: 12/31/2022] Open
Abstract
As an ideal method to manipulate biological particles, the dielectrophoresis (DEP) technique has been widely used in clinical diagnosis, disease treatment, drug development, immunoassays, cell sorting, etc. This review summarizes the research in the field of bioparticle manipulation based on DEP techniques. Firstly, the basic principle of DEP and its classical theories are introduced in brief; Secondly, a detailed introduction on the DEP technique used for bioparticle manipulation is presented, in which the applications are classified into five fields: capturing bioparticles to specific regions, focusing bioparticles in the sample, characterizing biomolecular interaction and detecting microorganism, pairing cells for electrofusion and separating different kinds of bioparticles; Thirdly, the effect of DEP on bioparticle viability is analyzed; Finally, the DEP techniques are summarized and future trends in bioparticle manipulation are suggested.
Collapse
|
21
|
Demircan Y, Özgür E, Külah H. Dielectrophoresis: applications and future outlook in point of care. Electrophoresis 2013; 34:1008-27. [PMID: 23348714 DOI: 10.1002/elps.201200446] [Citation(s) in RCA: 64] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2012] [Revised: 01/11/2013] [Accepted: 01/11/2013] [Indexed: 02/06/2023]
Abstract
Dielectrophoresis (DEP) is a label free, noninvasive, stand alone, rapid, and sensitive particle manipulation and characterization technique. Improvements in micro-electro-mechanical systems technology have enabled the biomedical applications of DEP over the past decades. By this way, integration of DEP into lab-on-a-chip systems has become achievable, creating a potential tool for point-of-care (POC) systems. DEP can be utilized in many different POC applications including early detection and prognosis of various cancer types, diagnosis of infectious diseases, blood cell analysis, and stem cell therapy. However, there are still some challenges to be resolved to have DEP-based devices available in POC market. Today, researchers have focused on these challenges to have this powerful theory as a solution for many POC applications. Here, DEP theory, cell modeling, and most common device structures are introduced briefly. Next, POC applications of DEP theory, such as cell (blood, cancer, stem, and fetal) and microorganism separation, manipulation, and enrichment for diagnosis and prognosis, are explained. Integration of DEP with other detection techniques to have more sensitive systems is summarized. Finally, future outlook for DEP-based systems are discussed with some challenges, which are currently preventing these systems to be a common tool for POC applications, and possible solutions.
Collapse
Affiliation(s)
- Yağmur Demircan
- Department of Electrical and Electronics Engineering, METU, Ankara, Turkey
| | | | | |
Collapse
|
22
|
Liao SH, Chang CY, Chang HC. A capillary dielectrophoretic chip for real-time blood cell separation from a drop of whole blood. BIOMICROFLUIDICS 2013; 7:24110. [PMID: 24404015 PMCID: PMC3645465 DOI: 10.1063/1.4802269] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/21/2013] [Accepted: 04/04/2013] [Indexed: 05/04/2023]
Abstract
This study proposes a capillary dielectrophoretic chip to separate blood cells from a drop of whole blood (approximately 1 μl) sample using negative dielectrophoretic force. The separating efficiency was evaluated by analyzing the image before and after dielectrophoretic force manipulation. Blood samples with various hematocrits (10%-60%) were tested with varied separating voltages and chip designs. In this study, a chip with 50 μm gap design achieved a separation efficiency of approximately 90% within 30 s when the hematocrit was in the range of 10%-50%. Furthermore, glucose concentration was electrochemically measured by separating electrodes following manipulation. The current response increased significantly (8.8-fold) after blood cell separation, which was attributed not only to the blood cell separation but also to sample disturbance by the dielectrophoretic force.
Collapse
Affiliation(s)
- Shu-Hsien Liao
- Department of Biomedical Engineering, National Cheng Kung University, Tainan, Taiwan
| | | | - Hsien-Chang Chang
- Department of Biomedical Engineering, National Cheng Kung University, Tainan, Taiwan ; Institute of Nanotechnology and Microsystems Engineering, National Cheng Kung University, Tainan, Taiwan ; Center for Micro/Nano Science and Technology, National Cheng Kung University, Tainan, Taiwan ; Medical Device Innovation Center, National Cheng Kung University, Tainan, Taiwan
| |
Collapse
|