1
|
Munusamy S, Zheng H, Jahani R, Zhou S, Chen J, Kong J, Guan X. Enzyme-free immunoassay for rapid, sensitive, and selective detection of C-reactive protein. Anal Bioanal Chem 2024; 416:6985-6994. [PMID: 39419834 DOI: 10.1007/s00216-024-05598-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2024] [Revised: 09/27/2024] [Accepted: 10/07/2024] [Indexed: 10/19/2024]
Abstract
C-reactive protein (CRP) is a protein made by the liver, which is released into the bloodstream in response to inflammation. Furthermore, CRP is a potential risk factor for heart disease. Hence, it is of great importance to develop a rapid, sensitive, accurate, and cost-effective method for CRP detection. Herein, we report an enzyme-free fluorescent assay for the rapid and ultra-sensitive detection of CRP with a limit of detection (LOD) reaching as low as 3.08 pg/mL (i.e., ~ 27 fM). The high sensitivity of our method was simply achieved via dual-functionalized gold nanoparticles (AuNPs). By regulating the molar ratio of DNA to CRP antibody immobilized on the AuNP surface, hundreds to thousands-fold amplification in the analyte signal could be instantly accomplished. Furthermore, our sensor was selective: non-target proteins such as interleukin-6, interleukin-1β, procalcitonin, bovine serum albumin, and human serum albumin did not interfere with the target CRP detection. Moreover, simulated serum samples were successfully analyzed. Given the excellent sensitivity, selectivity, and high resistance to complicated matrices, the enzyme-free CRP detection strategy developed in this work can be used as a generic platform to construct sensors for a wide variety of protein biomarkers and hence offers potential as a tool for rapid, accurate, and low-cost medical diagnosis.
Collapse
Affiliation(s)
| | - Haiyan Zheng
- Department of Chemistry, University of Missouri, Columbia, MO, 65211, USA
| | - Rana Jahani
- Department of Chemistry, University of Missouri, Columbia, MO, 65211, USA
| | - Shuo Zhou
- Department of Chemistry, University of Missouri, Columbia, MO, 65211, USA
| | - Jun Chen
- Department of Chemistry, University of Missouri, Columbia, MO, 65211, USA
| | - Juanhua Kong
- Department of Chemistry, University of Missouri, Columbia, MO, 65211, USA
| | - Xiyun Guan
- Department of Chemistry, University of Missouri, Columbia, MO, 65211, USA.
| |
Collapse
|
2
|
Shao J, Zhang W, Huang Y, Zheng J, Chi Y. Au Nanoparticles-Trisbipyridine Ruthenium(II) Nanoaggregates as Signal-Amplifying SERS Tags for Immunoassay of cTnI. ACS APPLIED MATERIALS & INTERFACES 2024; 16:61703-61713. [PMID: 39481089 DOI: 10.1021/acsami.4c13978] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/02/2024]
Abstract
Acute myocardial infarction (AMI) is one of the leading causes of human mortality worldwide. In the early stages of AMI, the patient's electrocardiogram (ECG) may not change, so the fast, sensitive, and accurate detection of the specific biomarker of cardiac troponin I (cTnI) is of great importance in the early diagnosis of AMI. In this work, for the first time, electrostatic nanoaggregates of negatively charged Au nanoparticles and positively charged trisbipyridine ruthenium(II) ions (i.e., (-)AuNPs|[Ru(bpy)3]2+ ENAs) as novel and signal-amplifying surface-enhanced Raman scattering (SERS) tags were synthesized in an easy and rapid (<3 min) way and applied in the highly sensitive, rapid detection of cTnI in human serum by being combined with an immunochromatographic test strip (ICTS). The synthesized (-)AuNPs|[Ru(bpy)3]2+ ENAs exhibited strong SERS activity due to the multiple Raman-active units (three bpy ligands) carried by each [Ru(bpy)3]2+ complex ion and abundant hotspots in each SERS tag. The developed (-)AuNPs|[Ru(bpy)3]2+ ENAs-based SERS-ICTS has been validated to be applicable in detection of cTnI in human serum with excellent sensing performances, such as fast testing (5 min) and a low detection limit (60 pg/mL). It is envisioned that the developed (-)AuNPs|[Ru(bpy)3]2+ ENAs-based SERS-ICTS sensor may have promising applications in point of care testing of various biomarkers in clinic. Additionally, this work may inspire the finding and the application of new types of Raman reporter molecules based on high valent metal-multi ligand coordination compounds like [Ru(bpy)3]2+.
Collapse
Affiliation(s)
- Jiwei Shao
- MOE Key Laboratory for Analytical Science of Food Safety and Biology, Fujian Provincial Key Laboratory of Analysis and Detection for Food Safety, College of Chemistry, Fuzhou University, Fuzhou, Fujian 350108, China
| | - Weiwei Zhang
- MOE Key Laboratory for Analytical Science of Food Safety and Biology, Fujian Provincial Key Laboratory of Analysis and Detection for Food Safety, College of Chemistry, Fuzhou University, Fuzhou, Fujian 350108, China
| | - Yun Huang
- MOE Key Laboratory for Analytical Science of Food Safety and Biology, Fujian Provincial Key Laboratory of Analysis and Detection for Food Safety, College of Chemistry, Fuzhou University, Fuzhou, Fujian 350108, China
| | - Jingcheng Zheng
- MOE Key Laboratory for Analytical Science of Food Safety and Biology, Fujian Provincial Key Laboratory of Analysis and Detection for Food Safety, College of Chemistry, Fuzhou University, Fuzhou, Fujian 350108, China
| | - Yuwu Chi
- MOE Key Laboratory for Analytical Science of Food Safety and Biology, Fujian Provincial Key Laboratory of Analysis and Detection for Food Safety, College of Chemistry, Fuzhou University, Fuzhou, Fujian 350108, China
| |
Collapse
|
3
|
Yuan W, Yuan H, Li R, Yong R, Mitrovic I, Lim EG, Duan S, Song P. A SERS nanocellulose-paper-based analytical device for ultrasensitive detection of Alzheimer's disease. Anal Chim Acta 2024; 1301:342447. [PMID: 38553119 DOI: 10.1016/j.aca.2024.342447] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2023] [Revised: 02/28/2024] [Accepted: 03/03/2024] [Indexed: 04/02/2024]
Abstract
BACKGROUND Alzheimer's disease (AD), one of the most prevalent neurodegenerative diseases, results in severe cognitive decline and irreversible memory loss. Early detection of AD is significant to patients for personalized intervention since effective cure and treatment methods for AD are still lacking. Despite the severity of the disease, existing highly sensitive AD detection methods, including neuroimaging and brain deposit-positive lesion tests, are not suitable for screening purposes due to their high cost and complicated operation. Therefore, these methods are unsuitable for early detection, especially in low-resource settings. Although regular paper-based microfluidics are cost-efficient for AD detection, they are restricted by a poor limit of detection (LOD). RESULTS To address the above limitations, we report the ultrasensitive and low-cost nanocellulose paper (nanopaper)-based analytical microfluidic devices (NanoPADs) for detecting one of the promising AD blood biomarkers (glial fibrillary acidic protein, GFAP) using Surface-enhanced Raman scattering (SERS) immunoassay. Nanopaper offers advantages as a SERS substrate, such as an ultrasmooth surface, high optical transparency, and tunable chemical properties. We detected the target GFAP in artificial serum, achieving a LOD of 150 fg mL-1. SIGNIFICANCE The developed NanoPADs are distinguished by their cost-efficiency and ease of implementation, presenting a promising avenue for effective early detection of AD's GFAP biomarker with ultrahigh sensitivity. More importantly, our work provides the experimental routes for SERS-based immunoassay of biomarkers on NanoPADs for various diseases in the future.
Collapse
Affiliation(s)
- Wenwen Yuan
- School of Advanced Technology, Xi'an Jiaotong - Liverpool University, 215123, Suzhou, China; Department of Electrical Engineering and Electronics, University of Liverpool, L69 7ZX, Liverpool, UK; State Key Laboratory for Manufacturing Systems Engineering, Xi'an Jiaotong University, 710049, Xi'an, China
| | - Hang Yuan
- School of Advanced Technology, Xi'an Jiaotong - Liverpool University, 215123, Suzhou, China
| | - Ruibing Li
- Department of Clinical Laboratory Medicine, The First Medical Centre, Chinese 301 General Hospital, 100853, Beijing, China
| | - Ruiqi Yong
- School of Advanced Technology, Xi'an Jiaotong - Liverpool University, 215123, Suzhou, China
| | - Ivona Mitrovic
- Department of Electrical Engineering and Electronics, University of Liverpool, L69 7ZX, Liverpool, UK
| | - Eng Gee Lim
- School of Advanced Technology, Xi'an Jiaotong - Liverpool University, 215123, Suzhou, China; Department of Electrical Engineering and Electronics, University of Liverpool, L69 7ZX, Liverpool, UK
| | - Sixuan Duan
- School of Advanced Technology, Xi'an Jiaotong - Liverpool University, 215123, Suzhou, China; Department of Electrical Engineering and Electronics, University of Liverpool, L69 7ZX, Liverpool, UK; Key Laboratory of Bionic Engineering, Jilin University, 130022, Changchun, China
| | - Pengfei Song
- School of Advanced Technology, Xi'an Jiaotong - Liverpool University, 215123, Suzhou, China; Department of Electrical Engineering and Electronics, University of Liverpool, L69 7ZX, Liverpool, UK.
| |
Collapse
|
4
|
Oliveira D, Carneiro MCCG, Moreira FTC. SERS biosensor with plastic antibodies for detection of a cancer biomarker protein. Mikrochim Acta 2024; 191:238. [PMID: 38570401 PMCID: PMC10991021 DOI: 10.1007/s00604-024-06327-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2024] [Accepted: 03/23/2024] [Indexed: 04/05/2024]
Abstract
Surface-enhanced Raman scattering (SERS) is a powerful method for detecting breast cancer-specific biomarkers due to its extraordinary enhancement effects obtained by localized surface plasmon resonance (LSPR) in metallic nanostructures at hotspots. In this research, gold nanostars (AuNSs) were used as SERS probes to detect a cancer biomarker at very low concentrations. To this end, we combined molecularly imprinted polymers (MIPs) as a detection layer with SERS for the detection of the biomarker CA 15-3 in point-of-care (PoC) analysis. This required two main steps: (i) the deposition of MIPs on a gold electrode, followed by a second step (ii) antibody binding with AuNSs containing a suitable Raman reporter to enhance Raman signaling (SERS). The MPan sensor was prepared by electropolymerization of the monomer aniline in the presence of CA 15-3. The template molecule was then extracted from the polymer using sodium dodecyl sulfate (SDS). In parallel, a control material was prepared in the absence of the protein (NPan). Surface modification for the control was performed using electrochemical techniques such as cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The performance of the sensor was evaluated using the SERS technique, in which the MPan sensor is first incubated with the protein and then exposed to the SERS probe. Under optimized conditions, the device showed a linear response to CA 15-3 concentrations from 0.016 to 248.51 U mL-1 in a PBS buffer at pH 7.4 in 1000-fold diluted serum. Overall, this approach demonstrates the potential of SERS as an optical reader and opens a new avenue for biosensing applications.
Collapse
Affiliation(s)
- Daniela Oliveira
- CIETI - LabRISE-School of Engineering, Polytechnic of Porto, R. Dr. António Bernardino de Almeida, 431, 4249-015, Porto, Portugal
| | - Mariana C C G Carneiro
- CIETI - LabRISE-School of Engineering, Polytechnic of Porto, R. Dr. António Bernardino de Almeida, 431, 4249-015, Porto, Portugal
| | - Felismina T C Moreira
- CIETI - LabRISE-School of Engineering, Polytechnic of Porto, R. Dr. António Bernardino de Almeida, 431, 4249-015, Porto, Portugal.
| |
Collapse
|
5
|
Guo J, Zhou Y, Cheng J, Chen F, Xu J, Yang L, Shi H, An Z, Guo J, Ma X. Afterglow Nanoprobe-Enabled Quantitative Lateral Flow Immunoassay by a Palm-Size Device for Household Healthcare. Anal Chem 2024; 96:4891-4900. [PMID: 38462674 DOI: 10.1021/acs.analchem.3c05448] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/12/2024]
Abstract
Lateral flow immunoassay (LFIA), a classical point-of-care testing (POCT) technique, plays an important role in disease screening and healthcare monitoring. However, traditional LFIA is either designed for qualitative analysis or requires expensive equipment for quantification, limiting its use in household diagnosis. In this study, we proposed a new generation of LFIA for household health monitoring by using ultralong organic phosphorescence (UOP) nanomaterials as afterglow nanoprobes with a self-developed palm-size sensing device. The UOP nanoprobes exhibit a phosphorescence signal with a second-level lifetime, which completely avoids the interference from excitation light and biological background fluorescence. Therefore, an ultraminiaturized and low-cost UOP nanosensor was successfully designed by eliminating the complex optical path and filtering systems. We chose an inflammatory factor, C-reactive protein (CRP), for household POCT validation. The whole analysis was completed within 9 min. A limit of detection (LOD) of 0.54 ng/mL of CRP antigen was achieved with high stability and good specificity, which is comparable to laboratory instruments and fully satisfying the clinical diagnosis requirement.
Collapse
Affiliation(s)
- Jiuchuan Guo
- University of Electronic Science and Technology of China, Chengdu 611731, China
| | - Yudong Zhou
- Key Laboratory of Flexible Electronics (KLOFE) and Institute of Advanced Materials (IAM), Nanjing Tech University (NanjingTech), 30 South Puzhu Road, Nanjing 211816, China
| | - Jie Cheng
- University of Electronic Science and Technology of China, Chengdu 611731, China
| | - Fuli Chen
- Sauvage Laboratory for Smart Materials, School of Materials Science and Engineering, Harbin Institute of Technology (Shenzhen), Shenzhen 518055, China
| | - Jiahui Xu
- Key Laboratory of Flexible Electronics (KLOFE) and Institute of Advanced Materials (IAM), Nanjing Tech University (NanjingTech), 30 South Puzhu Road, Nanjing 211816, China
| | - Lirong Yang
- Key Laboratory of Flexible Electronics (KLOFE) and Institute of Advanced Materials (IAM), Nanjing Tech University (NanjingTech), 30 South Puzhu Road, Nanjing 211816, China
| | - Huifang Shi
- Key Laboratory of Flexible Electronics (KLOFE) and Institute of Advanced Materials (IAM), Nanjing Tech University (NanjingTech), 30 South Puzhu Road, Nanjing 211816, China
| | - Zhongfu An
- Key Laboratory of Flexible Electronics (KLOFE) and Institute of Advanced Materials (IAM), Nanjing Tech University (NanjingTech), 30 South Puzhu Road, Nanjing 211816, China
| | - Jinhong Guo
- School of Sensing Science and Engineering, Shanghai Jiaotong University, Shanghai 200240, China
| | - Xing Ma
- Sauvage Laboratory for Smart Materials, School of Materials Science and Engineering, Harbin Institute of Technology (Shenzhen), Shenzhen 518055, China
| |
Collapse
|
6
|
An QQ, Feng XZ, Zhan T, Cheng YY, Han GC, Chen Z, Kraatz HB. A simple synthesis of a core-shell structure PPy-Au nanocomposite for immunosensing of C-reactive protein. Talanta 2024; 267:125158. [PMID: 37683320 DOI: 10.1016/j.talanta.2023.125158] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2023] [Revised: 07/21/2023] [Accepted: 09/02/2023] [Indexed: 09/10/2023]
Abstract
High-sensitivity C-reactive protein (hs-CRP) is an inflammatory biomarker and can accurately predict the development of cardiovascular disease (CVD). We synthesized a core-shell structure PPy-Au nanocomposite in situ by chemically oxidizing pyrrole (Py) with HAuCl4 and the produced Au nanoparticles realized the doping in the polymerization. Analysis of morphology and energy spectrum as well as electrochemical characterization confirmed the successful one-pot synthesis. The conductive polymers with porous structure provide abundant sites for anti-CRP binding and effectively enhanced the sensitivity of the label-free BSA/anti-CRP/PPy-Au/GCE immunosensor. Its analytical performance was observed using differential pulse voltammetry (DPV), with a linear range from 0.0005 to 60 μg mL-1 and a detection limit of 0.17 ng mL-1. The platform demonstrated satisfactory selectivity, stability, and reproducibility. To validate its clinical application, we detected CRP in human serum samples with a recovery rate of 101.00-105.95% and investigated the consistency of the developed method and immunoturbidimetry with a deviation between -1.2% and +3.2%, suggesting great potential for use in point-of-care testing (POCT).
Collapse
Affiliation(s)
- Qi-Qi An
- School of Life and Environmental Sciences, Guilin University of Electronic Technology, Guilin, 541004, PR China
| | - Xiao-Zhen Feng
- School of Life and Environmental Sciences, Guilin University of Electronic Technology, Guilin, 541004, PR China
| | - Tao Zhan
- School of Life and Environmental Sciences, Guilin University of Electronic Technology, Guilin, 541004, PR China
| | - Yun-Yun Cheng
- School of Life and Environmental Sciences, Guilin University of Electronic Technology, Guilin, 541004, PR China
| | - Guo-Cheng Han
- School of Life and Environmental Sciences, Guilin University of Electronic Technology, Guilin, 541004, PR China.
| | - Zhencheng Chen
- School of Life and Environmental Sciences, Guilin University of Electronic Technology, Guilin, 541004, PR China.
| | - Heinz-Bernhard Kraatz
- Department of Physical and Environmental Sciences, University of Toronto Scarborough, Toronto, Ontario, M1C 1A4, Canada.
| |
Collapse
|
7
|
Yu Q, Wu T, Tian B, Li J, Liu Y, Wu Z, Jin X, Wang C, Wang C, Gu B. Recent advances in SERS-based immunochromatographic assay for pathogenic microorganism diagnosis: A review. Anal Chim Acta 2024; 1286:341931. [PMID: 38049231 DOI: 10.1016/j.aca.2023.341931] [Citation(s) in RCA: 10] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2023] [Revised: 10/02/2023] [Accepted: 10/17/2023] [Indexed: 12/06/2023]
Abstract
Infectious diseases caused by bacteria, viruses, fungi, and other pathogenic microorganisms are among the most harmful public health problems in the world, causing tens of millions of deaths and incalculable economic losses every year. The establishment of rapid, simple, and highly sensitive diagnostic methods for pathogenic microorganisms is important for the prevention and control of infectious diseases, guidance of timely treatment, and the reduction of public safety risks. Lateral flow immunoassay (LFA) based on the colorimetric signal of colloidal gold is the most popular point-of-care testing technology at present, but it is limited by poor sensitivity and low throughput and hardly meets the needs of the highly sensitive screening of pathogenic microorganisms. In recent years, the combination of surface-enhanced Raman scattering (SERS) and LFA technology has developed into a novel analytical platform with high sensitivity and multiple detection capabilities and has shown great advantages in the detection of pathogenic microorganisms and infectious diseases. This review summarizes the working principle, design ideas, and application of the existing SERS-based LFA methods in pathogenic microorganism detection and further introduces the effect of new technologies such as Raman signal encoding, magnetic enrichment, novel membrane nanotags, and integrated Raman reading equipment on the performance of SERS-LFA. Finally, the main challenges and the future direction of development in this field of SERS-LFA are discussed.
Collapse
Affiliation(s)
- Qing Yu
- Department of Clinical Laboratory Medicine, Guangdong Provincial People's Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou, Guangdong, 510000, China; College of Life Sciences, Anhui Agricultural University, Hefei, 230036, China
| | - Ting Wu
- Department of Clinical Laboratory Medicine, Guangdong Provincial People's Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou, Guangdong, 510000, China
| | - Benshun Tian
- Department of Clinical Laboratory Medicine, Guangdong Provincial People's Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou, Guangdong, 510000, China
| | - Jiaxuan Li
- Department of Clinical Laboratory Medicine, Guangdong Provincial People's Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou, Guangdong, 510000, China
| | - Yun Liu
- Department of Clinical Laboratory Medicine, Guangdong Provincial People's Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou, Guangdong, 510000, China
| | - Zelan Wu
- Guangzhou Labway Clinical Laboratory Co., Ltd, Guangdong, 510000, China
| | - Xiong Jin
- Guangzhou Labway Clinical Laboratory Co., Ltd, Guangdong, 510000, China
| | - Chaoguang Wang
- College of Intelligence Science and Technology, National University of Defense Technology, Changsha, 410073, China.
| | - Chongwen Wang
- Department of Clinical Laboratory Medicine, Guangdong Provincial People's Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou, Guangdong, 510000, China; College of Life Sciences, Anhui Agricultural University, Hefei, 230036, China.
| | - Bing Gu
- Department of Clinical Laboratory Medicine, Guangdong Provincial People's Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou, Guangdong, 510000, China.
| |
Collapse
|
8
|
Ebbah E, Amissah A, Kim JH, Driskell JD. SERS-based immunoassay on a plasmonic syringe filter for improved sampling and labeling efficiency of biomarkers. Analyst 2023; 149:221-230. [PMID: 38018888 DOI: 10.1039/d3an01899g] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2023]
Abstract
Rapid, sensitive, and quantitative detection of biomarkers is needed for early diagnosis of disease and surveillance of infectious outbreaks. Here, we exploit a plasmonic syringe filter and surface-enhanced Raman spectroscopy (SERS) in the development of a rapid detection system, using human IgG as a model diagnostic biomarker. The novel assay design facilitates multiple passages of the sample and labeling solution through the detection zone enabling us to investigate and maximize sampling efficiency to the capture substrate. The vertical flow immunoassay process in this study involves the utilization of filter paper embedded with gold nanoparticles (AuNPs) to form a plasmonic substrate. Capture antibody (anti-human IgG) is then immobilized onto the prepared plasmonic paper and inserted into a vertical flow device (syringe filter holder). Sample solution is passed through the filter paper and the target antigen (human IgG) is selectively captured by the immobilized antibody to form an antibody-antigen complex. Next, functionalized AuNPs as extrinsic Raman labels (ERLs) are passed through the filter paper to label the captured biomarker molecules forming a layered structure. This sandwiched geometry enhances plasmonic coupling and SERS signal to provide highly sensitive detection of biomolecules. Systematic studies to investigate the impact of multiple infuse/withdraw cycles of the sample and labeling solutions reveal that antigen and ERL binding are maximized with 10 and 20 cycles, respectively. The optimized assay achieves a detection limit of ∼0.2 ng mL-1 for human IgG with a total assay time of less than 5 minutes, meeting the demands for rapid point of care diagnostics. Additionally, the optimized platform was implemented in the quantitative analysis of the SARS-CoV-2 nucleocapsid protein, the typical target in commercial, FDA-approved rapid antigen tests for COVID-19.
Collapse
Affiliation(s)
- Eunice Ebbah
- Department of Chemistry, Illinois State University, Normal, IL 61790, USA.
| | - Anthony Amissah
- Department of Chemistry, Illinois State University, Normal, IL 61790, USA.
| | - Jun-Hyun Kim
- Department of Chemistry, Illinois State University, Normal, IL 61790, USA.
| | - Jeremy D Driskell
- Department of Chemistry, Illinois State University, Normal, IL 61790, USA.
| |
Collapse
|
9
|
Jin B, Du Z, Ji J, Bai Y, Tang D, Qiao L, Lou J, Hu J, Li Z. Regulation of probe density on upconversion nanoparticles enabling high-performance lateral flow assays. Talanta 2023; 256:124327. [PMID: 36758506 DOI: 10.1016/j.talanta.2023.124327] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2022] [Revised: 01/17/2023] [Accepted: 02/03/2023] [Indexed: 02/09/2023]
Abstract
Upconversion nanoparticles (UCNPs)-based fluorescence probes have shown great potential in point-of-care testing (POCT) applications, due to UCNPs' features of high photostability and background-free fluorescence. Ceaseless improvements of UCNPs-probes have been carried out to increase detection sensitivity and to broaden detection range of UCNPs-based POCT. In this paper, we optimized UCNPs-probes by regulating probe density. The optimization was verified by a traditional lateral flow assay (LFA) platform for C-reactive protein (CRP) detection. Further, the optimized UCNPs-LFA integrating with a home-made benchtop fluorescence analyzer holds the capability to achieve high-performance POCT. Finally, nearly a 20 times sensitivity enhancement with a limit of detection of 0.046 ng/mL and a broad detection range of 0.2-300 ng/mL for CRP detection was obtained. Moreover, the optimized UCNPs-LFA was applied to detecting CRP in clinical serum samples and the detection results were consistent with the clinical test, validating its clinical practicability. The proposed optimization method is also expected to optimize other nanoparticles-based bio-probes for wider POCT application.
Collapse
Affiliation(s)
- Birui Jin
- School of Materials and Chemical Engineering, Xi'an Technological University, Xi'an, 710021, China; Bioinspired Engineering and Biomechanics Center (BEBC), Xi'an Jiaotong University, Xi'an, 710049, China
| | - Zhiguo Du
- School of Materials and Chemical Engineering, Xi'an Technological University, Xi'an, 710021, China
| | - Jingcheng Ji
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Xi'an Jiaotong University, Xi'an, 710049, China; Bioinspired Engineering and Biomechanics Center (BEBC), Xi'an Jiaotong University, Xi'an, 710049, China
| | - Yuemeng Bai
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Xi'an Jiaotong University, Xi'an, 710049, China; Bioinspired Engineering and Biomechanics Center (BEBC), Xi'an Jiaotong University, Xi'an, 710049, China
| | - Deding Tang
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Xi'an Jiaotong University, Xi'an, 710049, China; Bioinspired Engineering and Biomechanics Center (BEBC), Xi'an Jiaotong University, Xi'an, 710049, China; Maanshan Teachers College, Ma Anshan, 243041, China
| | - Lihua Qiao
- Department of Laboratory Medicine, Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai, 200030, China
| | - Jiatao Lou
- Department of Laboratory Medicine, Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai, 200030, China; Department of Laboratory Medicine, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200080, China
| | - Jie Hu
- Suzhou DiYinAn Biotech Co., Ltd., Suzhou Innovation Center for Life Science and Technology, Suzhou, 215129, China.
| | - Zedong Li
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Xi'an Jiaotong University, Xi'an, 710049, China; Bioinspired Engineering and Biomechanics Center (BEBC), Xi'an Jiaotong University, Xi'an, 710049, China.
| |
Collapse
|
10
|
Beeram R, Vepa KR, Soma VR. Recent Trends in SERS-Based Plasmonic Sensors for Disease Diagnostics, Biomolecules Detection, and Machine Learning Techniques. BIOSENSORS 2023; 13:328. [PMID: 36979540 PMCID: PMC10046859 DOI: 10.3390/bios13030328] [Citation(s) in RCA: 22] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/31/2023] [Revised: 02/20/2023] [Accepted: 02/24/2023] [Indexed: 06/18/2023]
Abstract
Surface-enhanced Raman spectroscopy/scattering (SERS) has evolved into a popular tool for applications in biology and medicine owing to its ease-of-use, non-destructive, and label-free approach. Advances in plasmonics and instrumentation have enabled the realization of SERS's full potential for the trace detection of biomolecules, disease diagnostics, and monitoring. We provide a brief review on the recent developments in the SERS technique for biosensing applications, with a particular focus on machine learning techniques used for the same. Initially, the article discusses the need for plasmonic sensors in biology and the advantage of SERS over existing techniques. In the later sections, the applications are organized as SERS-based biosensing for disease diagnosis focusing on cancer identification and respiratory diseases, including the recent SARS-CoV-2 detection. We then discuss progress in sensing microorganisms, such as bacteria, with a particular focus on plasmonic sensors for detecting biohazardous materials in view of homeland security. At the end of the article, we focus on machine learning techniques for the (a) identification, (b) classification, and (c) quantification in SERS for biology applications. The review covers the work from 2010 onwards, and the language is simplified to suit the needs of the interdisciplinary audience.
Collapse
Affiliation(s)
| | | | - Venugopal Rao Soma
- Advanced Centre of Research in High Energy Materials (ACRHEM), DRDO Industry Academia—Centre of Excellence (DIA-COE), University of Hyderabad, Hyderabad 500046, Telangana, India
| |
Collapse
|
11
|
A SERS-based immunochromatographic assay for ultrasensitive and quantitative detection of florfenicol using long wavelength absorption of Au nanocubes. FOOD AGR IMMUNOL 2022. [DOI: 10.1080/09540105.2022.2120852] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
|
12
|
Jin B, Du Z, Zhang C, Yu Z, Wang X, Hu J, Li Z. Eu-Chelate Polystyrene Microsphere-Based Lateral Flow Immunoassay Platform for hs-CRP Detection. BIOSENSORS 2022; 12:977. [PMID: 36354486 PMCID: PMC9688000 DOI: 10.3390/bios12110977] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/21/2022] [Revised: 10/25/2022] [Accepted: 11/01/2022] [Indexed: 06/16/2023]
Abstract
Inflammation caused by viral or bacterial infection is a major threat to human health globally. Blood C-reactive protein (CRP) has been proven to be a sensitive indicator for the occurrence and development of inflammation. Furthermore, a tiny change of blood CRP concentration may portend chronic diseases; therefore, high-sensitivity CRP (hs-CRP) detection in a quantitative, rapid, user-friendly, and low-cost manner is highly demanded. In this paper, we developed a europium-chelate polystyrene microsphere (EuPSM)-based lateral flow immunoassay (LFIA) integrating with a benchtop fluorescence analyzer for hs-CRP detection. The optimization of the EuPSM-based LFIA was implemented through adjusting the antibody density on EuPSM from 100% to 60% of the saturated density. Finally, the limit of detection of 0.76 pg/mL and detection range of 0.025-250 ng/mL were obtained. Moreover, the clinical application capability of the proposed platform was validated through detecting CRP in clinical serum samples, showing high consistency with the results obtained from the clinical standard method. Hence, the proposed EuPSM-based LFIA has been verified to be well suitable for hs-CRP detection, while also showing great applicability for sensitively and rapidly detecting other biomarkers.
Collapse
Affiliation(s)
- Birui Jin
- School of Materials and Chemical Engineering, Xi’an Technological University, Xi’an 710021, China
- Bioinspired Engineering and Biomechanics Center (BEBC), Xi’an Jiaotong University, Xi’an 710049, China
| | - Zhiguo Du
- School of Materials and Chemical Engineering, Xi’an Technological University, Xi’an 710021, China
| | - Chuyao Zhang
- School of Materials and Chemical Engineering, Xi’an Technological University, Xi’an 710021, China
| | - Zhao Yu
- Xi’an Thermal Power Research Institute Co., Ltd., Xi’an 710054, China
| | - Xuemin Wang
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi’an Jiaotong University, Xi’an 710049, China
- Department of Radiotherapy Hospital Unit Radiation Therapy, Shaanxi Provincial Tumor Hospital, Xi’an 710061, China
| | - Jie Hu
- Suzhou DiYinAn Biotech Co., Ltd., Suzhou Innovation Center for Life Science and Technology, Suzhou 215129, China
| | - Zedong Li
- Bioinspired Engineering and Biomechanics Center (BEBC), Xi’an Jiaotong University, Xi’an 710049, China
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi’an Jiaotong University, Xi’an 710049, China
| |
Collapse
|
13
|
Ghasemi F, Fahimi-Kashani N, Bigdeli A, Alshatteri AH, Abbasi-Moayed S, Al-Jaf SH, Merry MY, Omer KM, Hormozi-Nezhad MR. Paper-based optical nanosensors – A review. Anal Chim Acta 2022; 1238:340640. [DOI: 10.1016/j.aca.2022.340640] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2022] [Revised: 11/15/2022] [Accepted: 11/16/2022] [Indexed: 11/23/2022]
|
14
|
Yin L, You T, El-Seedi HR, El-Garawani IM, Guo Z, Zou X, Cai J. Rapid and sensitive detection of zearalenone in corn using SERS-based lateral flow immunosensor. Food Chem 2022; 396:133707. [PMID: 35853376 DOI: 10.1016/j.foodchem.2022.133707] [Citation(s) in RCA: 28] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2022] [Revised: 07/12/2022] [Accepted: 07/12/2022] [Indexed: 11/29/2022]
Abstract
Zearalenone (ZEN) is a universal mycotoxin contaminant in corn and its products. A surface-enhanced Raman scattering (SERS) based test strip was proposed for the detection of ZEN, which had the advantages of simplicity, rapidity, and high sensitivity. Core-shell Au@AgNPs with embedded reporter molecules (4-MBA) were synthesized as SERS nanoprobe, which exhibited excellent SERS signals and high stability. The detection range of ZEN for corn samples was 10-1000 μg/kg with the limit of detection (LOD) of 3.6 μg/kg, which is far below the recommended tolerable level (60 μg/kg). More importantly, the SERS method was verified by HPLC in the application on corn samples contaminated with ZEN, and the coincidence rates were in the range of 86.06%-111.23%, suggesting a high accuracy of the SERS assay. Therefore, the SERS-based test strip with an analysis time of less than 15 min is a promising tool for accurate and rapid detection of ZEN-field contamination.
Collapse
Affiliation(s)
- Limei Yin
- Key Laboratory of Modern Agricultural Equipment and Technology, Ministry of Education, School of Agricultural Engineering, Jiangsu University, Zhenjiang 212013, China; School of Food and Biological Engineering, Jiangsu University, Zhenjiang 212013, China.
| | - Tianyan You
- Key Laboratory of Modern Agricultural Equipment and Technology, Ministry of Education, School of Agricultural Engineering, Jiangsu University, Zhenjiang 212013, China
| | - Hesham R El-Seedi
- Pharmacognosy Group, Department of Pharmaceutical Biosciences, BMC, Uppsala University, Box 591, SE-751 24 Uppsala, Sweden
| | - Islam M El-Garawani
- Department of Zoology, Faculty of Science, Menoufia University, Menoufia 32511, Egypt
| | - Zhiming Guo
- School of Food and Biological Engineering, Jiangsu University, Zhenjiang 212013, China; International Joint Research Laboratory of Intelligent Agriculture and Agri-products Processing (Jiangsu University), Jiangsu Education Department, Zhenjiang 212013, China
| | - Xiaobo Zou
- School of Food and Biological Engineering, Jiangsu University, Zhenjiang 212013, China; International Joint Research Laboratory of Intelligent Agriculture and Agri-products Processing (Jiangsu University), Jiangsu Education Department, Zhenjiang 212013, China
| | - Jianrong Cai
- School of Food and Biological Engineering, Jiangsu University, Zhenjiang 212013, China.
| |
Collapse
|
15
|
Liu H, Liu Y, Zhou T, Zhou P, Li J, Deng A. Ultrasensitive and Specific Detection of Anticancer Drug 5-Fluorouracil in Blood Samples by a Surface-Enhanced Raman Scattering (SERS)-Based Lateral Flow Immunochromatographic Assay. Molecules 2022; 27:4019. [PMID: 35807264 PMCID: PMC9268288 DOI: 10.3390/molecules27134019] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2022] [Revised: 06/18/2022] [Accepted: 06/20/2022] [Indexed: 12/10/2022] Open
Abstract
5-Fluorouracil (5-FU) is an effective anticancer drug widely used in the world. To improve therapy efficiency and reduce side effects, it is very important to frequently detect the concentration of 5-FU in blood samples of patients. In this work, a new type of lateral flow immunochromatographic assay (LFIA) based on surface-enhanced Raman scattering (SERS) for ultrasensitive and specific detection of 5-FU in blood samples was developed. Au@Ag/Au nanoparticles (NPs) employing Au particles as the core and Ag/Au alloy as the shell were synthesized, characterized and used as the substrate in SERS-LFIA due to their high SERS enhancement and biocompatibility. The immunoprobe was made in the form of AuMBA@Ag/Au-Ab in which mercaptobenzoic acid (MBA, a common Raman active reporter) was embedded in the core-shell layer and the monoclonal antibody (mAb) against 5-FU was immobilized on the surface. The performance of SERS-LFIA was similar to that in colloidal gold based-LFIA, and the entire assay time was within 20 min. According to the color intensity on the testing (T) lines of LFIA strips visualized by eyes, the contents of 5-FU in the samples could be qualitatively or semi-quantitatively identified. Furthermore, by measuring the characteristic Raman intensities of MBA on T lines, quantitative detection of 5-FU in the samples were achieved. The IC50 and limit of detection (LOD) of the LFIA for 5-FU were found to be 20.9 pg mL-1 and 4.4 pg mL-1, respectively. There was no cross-reactivity (CR) of the LFIA with nine relative compounds, and the CR with cytosine, tegafur and carmofur were less than 4.5%. The recoveries of 5-FU from spiked blood samples were in the range of 78.6~86.4% with the relative standard deviation (RSD) of 2.69~4.42%. Five blood samples containing 5-FU collected from the Cancer Hospital were measured by SERS-LFIA, and the results were confirmed by LC-MS/MS. It was proven that the proposed method was able to simply and rapidly detect 5-FU in blood samples with high sensitivity, specificity, accuracy and precision.
Collapse
Affiliation(s)
| | | | | | | | - Jianguo Li
- The Key Lab of Health Chemistry and Molecular Diagnosis of Suzhou, College of Chemistry, Chemical Engineering and Materials Science, Soochow University, Renai Road 199, Suzhou 215123, China; (H.L.); (Y.L.); (T.Z.); (P.Z.)
| | - Anping Deng
- The Key Lab of Health Chemistry and Molecular Diagnosis of Suzhou, College of Chemistry, Chemical Engineering and Materials Science, Soochow University, Renai Road 199, Suzhou 215123, China; (H.L.); (Y.L.); (T.Z.); (P.Z.)
| |
Collapse
|
16
|
Design of Gold Nanoparticle Vertical Flow Assays for Point-of-Care Testing. Diagnostics (Basel) 2022; 12:diagnostics12051107. [PMID: 35626263 PMCID: PMC9140445 DOI: 10.3390/diagnostics12051107] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2022] [Revised: 04/24/2022] [Accepted: 04/25/2022] [Indexed: 01/18/2023] Open
Abstract
Vertical flow assays (VFAs) or flow-through assays have emerged as an alternate type of paper-based assay due to their faster detection time, larger sample volume capacity, and significantly higher multiplexing capabilities. They have been successfully employed to detect several different targets (polysaccharides, protein, and nucleic acids), although in a limited number of samples (serum, whole blood, plasma) compared to the more commonly known lateral flow assays (LFAs). The operation of a VFA relies mainly on gravity, coupled with capillary action or external force to help the sample flow through layers of stacked pads. With recent developments in this field, multiple layers of pads and signal readers have been optimized for more user-friendly operation, and VFAs have achieved a lower limit of detection for various analytes than the gold-standard methods. Thus, compared to the more widely used LFA, the VFA demonstrates certain advantages and is becoming an increasingly popular platform for obtaining qualitative and quantitative results in low-resource settings. Considering the wide application of gold nanoparticles (GNPs) in VFAs, we will mostly discuss (1) the design of GNP-based VFA along with its associated advantages/disadvantages, (2) fabrication and optimization of GNP-based VFAs for applications, and (3) the future outlook of flow-based assays for point-of-care testing (POCT) diagnostics.
Collapse
|
17
|
Tauseef A, Hisam F, Hussain T, Caruso A, Hussain K, Châtel A, Chénais B. Nanomicrobiology: Emerging Trends in Microbial Synthesis of Nanomaterials and Their Applications. J CLUST SCI 2022. [DOI: 10.1007/s10876-022-02256-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
18
|
Wu J, Liang L, Zhang M, Zhu R, Wang Z, Yin Y, Yin B, Weng T, Fang S, Xie W, Wang L, Wang D. Single-Molecule Identification of the Conformations of Human C-Reactive Protein and Its Aptamer Complex with Solid-State Nanopores. ACS APPLIED MATERIALS & INTERFACES 2022; 14:12077-12088. [PMID: 35234028 DOI: 10.1021/acsami.2c00453] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Human C-reactive protein (CRP) is an established inflammatory biomarker and was proved to be potentially relevant to disease pathology and cancer progression. A large body of methodologies have been reported for CRP analysis, including electrochemical/optical biosensors, aptamer, or antibody-based detection. Although the detection limit is rather low until pg/uL, most of which are time-consuming and relatively expensive, and few of them provided CRP single-molecule information. This work demonstrated the nanopore-based approach for the characterization of CRP conformation under versatile conditions. With an optimized pore of 14 nm in diameter, we achieved the detection limit as low as 0.3 ng/μL, voltage polarity significantly influences the electro-osmotic force and CRP translocation behavior, and the pentameric conformation of CRP may dissociate into pro-inflammatory CRP isoforms and monomeric CRP at bias potential above 300 mV. CRP tends to translocate through nanopores faster along with the increase in pH values, due to more surface charge on both CRP and pore inner wall and stronger electro-osmotic force. The CRP could specifically bind with its aptamer of different concentrations to form complexes, and the complexes exhibited distinguishable nanopore translocation behavior compared with CRP alone. The variation of the molar ratio of aptamer significantly influences the orientation of CRP translocation. The plasma test under physiological conditions displayed the ability of the nanopore system on the CRP identification with a concentration of 3 ng/μL.
Collapse
Affiliation(s)
- Ji Wu
- Chongqing Key Laboratory of Multi-Scale Manufacturing Technology, Chongqing Institute of Green and Intelligent Technology, Chinese Academy of Sciences, Chongqing 400714, P. R. China
- Chongqing School, University of Chinese Academy of Science, Chongqing 400714, P. R. China
| | - Liyuan Liang
- Chongqing Key Laboratory of Multi-Scale Manufacturing Technology, Chongqing Institute of Green and Intelligent Technology, Chinese Academy of Sciences, Chongqing 400714, P. R. China
- Chongqing School, University of Chinese Academy of Science, Chongqing 400714, P. R. China
| | - Mingkun Zhang
- Chongqing Key Laboratory of Multi-Scale Manufacturing Technology, Chongqing Institute of Green and Intelligent Technology, Chinese Academy of Sciences, Chongqing 400714, P. R. China
- Chongqing School, University of Chinese Academy of Science, Chongqing 400714, P. R. China
| | - Rui Zhu
- Chongqing Key Laboratory of Multi-Scale Manufacturing Technology, Chongqing Institute of Green and Intelligent Technology, Chinese Academy of Sciences, Chongqing 400714, P. R. China
- Chongqing School, University of Chinese Academy of Science, Chongqing 400714, P. R. China
| | - Zhong Wang
- Chongqing Key Laboratory of Multi-Scale Manufacturing Technology, Chongqing Institute of Green and Intelligent Technology, Chinese Academy of Sciences, Chongqing 400714, P. R. China
- Chongqing School, University of Chinese Academy of Science, Chongqing 400714, P. R. China
| | - Yajie Yin
- Chongqing Key Laboratory of Multi-Scale Manufacturing Technology, Chongqing Institute of Green and Intelligent Technology, Chinese Academy of Sciences, Chongqing 400714, P. R. China
- Chongqing School, University of Chinese Academy of Science, Chongqing 400714, P. R. China
| | - Bohua Yin
- Chongqing Key Laboratory of Multi-Scale Manufacturing Technology, Chongqing Institute of Green and Intelligent Technology, Chinese Academy of Sciences, Chongqing 400714, P. R. China
- Chongqing School, University of Chinese Academy of Science, Chongqing 400714, P. R. China
| | - Ting Weng
- Chongqing Key Laboratory of Multi-Scale Manufacturing Technology, Chongqing Institute of Green and Intelligent Technology, Chinese Academy of Sciences, Chongqing 400714, P. R. China
- Chongqing School, University of Chinese Academy of Science, Chongqing 400714, P. R. China
| | - Shaoxi Fang
- Chongqing Key Laboratory of Multi-Scale Manufacturing Technology, Chongqing Institute of Green and Intelligent Technology, Chinese Academy of Sciences, Chongqing 400714, P. R. China
- Chongqing School, University of Chinese Academy of Science, Chongqing 400714, P. R. China
| | - Wanyi Xie
- Chongqing Key Laboratory of Multi-Scale Manufacturing Technology, Chongqing Institute of Green and Intelligent Technology, Chinese Academy of Sciences, Chongqing 400714, P. R. China
- Chongqing School, University of Chinese Academy of Science, Chongqing 400714, P. R. China
| | - Liang Wang
- Chongqing Key Laboratory of Multi-Scale Manufacturing Technology, Chongqing Institute of Green and Intelligent Technology, Chinese Academy of Sciences, Chongqing 400714, P. R. China
- Chongqing School, University of Chinese Academy of Science, Chongqing 400714, P. R. China
| | - Deqiang Wang
- Chongqing Key Laboratory of Multi-Scale Manufacturing Technology, Chongqing Institute of Green and Intelligent Technology, Chinese Academy of Sciences, Chongqing 400714, P. R. China
- Chongqing School, University of Chinese Academy of Science, Chongqing 400714, P. R. China
| |
Collapse
|
19
|
Sathishkumar N, Toley BJ. Paper-microfluidic signal-enhanced immunoassays. PROGRESS IN MOLECULAR BIOLOGY AND TRANSLATIONAL SCIENCE 2022; 186:267-288. [PMID: 35033288 DOI: 10.1016/bs.pmbts.2021.07.015] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Over the past decade, paper-based microfluidic devices have become popular for their simplicity and ability to conduct diagnostic tests at a low cost. An important class of diagnostic assays that paper-based analytical devices have been used for is immunoassays. The lateral flow immunoassay (LFIA), of which the home pregnancy test is the most prominent example, has been one of the most commercially successful membrane-based diagnostic tests. Yet, the analytical sensitivity of LFIAs is lower than the corresponding laboratory technique called ELISA (enzyme-linked immunoassay). As a consequence, traditional LFIAs fail to deliver on the promise of bedside diagnostic testing for many applications. Recognizing this shortcoming, several new developments have been made by researchers to enhance the sensitivity of membrane-based immunoassays. In this chapter, we present the various strategies that have been employed to this end. In the end, we present a brief SWOT analysis to guide future work in this area.
Collapse
Affiliation(s)
- N Sathishkumar
- Department of Chemical Engineering, Indian Institute of Science, Bengaluru, KA, India
| | - Bhushan J Toley
- Department of Chemical Engineering, Indian Institute of Science, Bengaluru, KA, India.
| |
Collapse
|
20
|
Tang Z, Zhao W, Deng Y, Sun Y, Qiu C, Wu B, Bao J, Chen Z, Yu L. Universal point-of-care detection of proteins based on proximity hybridization-mediated isothermal exponential amplification. Analyst 2022; 147:1709-1715. [DOI: 10.1039/d1an02245h] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
A lateral flow biosensor has been fabricated for protein detection based on a protein-to-DNA signal transducer, isothermal exponential amplification and catalytic hairpin assembly with high sensitivity and specificity.
Collapse
Affiliation(s)
- Zibin Tang
- School of Medical Technology, Guangdong Medical University, Dongguan 523808, China
| | - Wenyong Zhao
- Faculty of Forensic Medicine, School of Basic Medicine, Guangdong Medical University, Dongguan 523808, China
| | - Yuling Deng
- School of Medical Technology, Guangdong Medical University, Dongguan 523808, China
| | - Yuanzhong Sun
- School of Medical Technology, Guangdong Medical University, Dongguan 523808, China
| | - Cailing Qiu
- Department of Medical Laboratory, Dalang Hospital of Dongguan, Dongguan 523770, China
| | - Binhua Wu
- Marine Biomedical Research Institute of Guangdong Medical University, Zhanjiang, 524023, China
| | - Juan Bao
- School of Medical Technology, Guangdong Medical University, Dongguan 523808, China
| | - Zhangquan Chen
- School of Medical Technology, Guangdong Medical University, Dongguan 523808, China
| | - Luxin Yu
- School of Medical Technology, Guangdong Medical University, Dongguan 523808, China
| |
Collapse
|
21
|
Wang Z, Zhao J, Xu X, Guo L, Xu L, Sun M, Hu S, Kuang H, Xu C, Li A. An Overview for the Nanoparticles-Based Quantitative Lateral Flow Assay. SMALL METHODS 2022; 6:e2101143. [PMID: 35041285 DOI: 10.1002/smtd.202101143] [Citation(s) in RCA: 42] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/15/2021] [Revised: 10/27/2021] [Indexed: 06/14/2023]
Abstract
The development of the lateral flow assay (LFA) has received much attention in both academia and industry because of their broad applications to food safety, environmental monitoring, clinical diagnosis, and so forth. The user friendliness, low cost, and easy operation are the most attractive advantages of the LFA. In recent years, quantitative detection has become another focus of LFA development. Here, the most recent studies of quantitative LFAs are reviewed. First, the principles and corresponding formats of quantitative LFAs are introduced. In the biomaterial and nanomaterial sections, the detection, capture, and signal amplification biomolecules and the optical, fluorescent, luminescent, and magnetic labels used in LFAs are described. The invention of dedicated strip readers has drawn further interest in exploiting the better performance of LFAs. Therefore, next, the development of dedicated reader devices is described and the usefulness and specifications of these devices for LFAs are discussed. Finally, the applications of LFAs in the detection of metal ions, biotoxins, pathogenic microorganisms, veterinary drugs, and pesticides in the fields of food safety and environmental health and the detection of nucleic acids, biomarkers, and viruses in clinical analyses are summarized.
Collapse
Affiliation(s)
- Zhongxing Wang
- State Key Laboratory of Food Science and Technology, Jiangnan University, No. 1800, Lihu Road, Wuxi, Jiangsu, 214122, P. R. China
- International Joint Research Laboratory for Biointerface and Biodetection, and School of Food Science and Technology, Jiangnan University, No. 1800, Lihu Road, Wuxi, Jiangsu, 214122, P. R. China
| | - Jing Zhao
- Department of Radiology, Affiliated Hospital, Jiangnan University, No. 1000, Hefeng Road, Wuxi, Jiangsu, 214122, China
| | - Xinxin Xu
- State Key Laboratory of Food Science and Technology, Jiangnan University, No. 1800, Lihu Road, Wuxi, Jiangsu, 214122, P. R. China
- International Joint Research Laboratory for Biointerface and Biodetection, and School of Food Science and Technology, Jiangnan University, No. 1800, Lihu Road, Wuxi, Jiangsu, 214122, P. R. China
| | - Lingling Guo
- State Key Laboratory of Food Science and Technology, Jiangnan University, No. 1800, Lihu Road, Wuxi, Jiangsu, 214122, P. R. China
- International Joint Research Laboratory for Biointerface and Biodetection, and School of Food Science and Technology, Jiangnan University, No. 1800, Lihu Road, Wuxi, Jiangsu, 214122, P. R. China
| | - Liguang Xu
- State Key Laboratory of Food Science and Technology, Jiangnan University, No. 1800, Lihu Road, Wuxi, Jiangsu, 214122, P. R. China
- International Joint Research Laboratory for Biointerface and Biodetection, and School of Food Science and Technology, Jiangnan University, No. 1800, Lihu Road, Wuxi, Jiangsu, 214122, P. R. China
| | - Maozhong Sun
- State Key Laboratory of Food Science and Technology, Jiangnan University, No. 1800, Lihu Road, Wuxi, Jiangsu, 214122, P. R. China
- International Joint Research Laboratory for Biointerface and Biodetection, and School of Food Science and Technology, Jiangnan University, No. 1800, Lihu Road, Wuxi, Jiangsu, 214122, P. R. China
| | - Shudong Hu
- Department of Radiology, Affiliated Hospital, Jiangnan University, No. 1000, Hefeng Road, Wuxi, Jiangsu, 214122, China
| | - Hua Kuang
- State Key Laboratory of Food Science and Technology, Jiangnan University, No. 1800, Lihu Road, Wuxi, Jiangsu, 214122, P. R. China
- International Joint Research Laboratory for Biointerface and Biodetection, and School of Food Science and Technology, Jiangnan University, No. 1800, Lihu Road, Wuxi, Jiangsu, 214122, P. R. China
| | - Chuanlai Xu
- State Key Laboratory of Food Science and Technology, Jiangnan University, No. 1800, Lihu Road, Wuxi, Jiangsu, 214122, P. R. China
- International Joint Research Laboratory for Biointerface and Biodetection, and School of Food Science and Technology, Jiangnan University, No. 1800, Lihu Road, Wuxi, Jiangsu, 214122, P. R. China
| | - Aike Li
- Academy of National Food and Strategic Reserves Administration, No. 11, Baiwanzhuang Street, Beijing, 100037, P. R. China
| |
Collapse
|
22
|
Tang S, Liu H, Tian Y, Chen D, Gu C, Wei G, Jiang T, Zhou J. Surface-enhanced Raman scattering-based lateral flow immunoassay mediated by hydrophilic-hydrophobic Ag-modified PMMA substrate. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2021; 262:120092. [PMID: 34175758 DOI: 10.1016/j.saa.2021.120092] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/01/2021] [Revised: 06/14/2021] [Accepted: 06/16/2021] [Indexed: 05/18/2023]
Abstract
Recently, it is urgent to ameliorate the accumulation and quantification performances of surface-enhanced Raman scattering-based lateral flow immunoassay (SERS-based LFIA) to promote its reliable clinical application. Herein, a smart hydrophilic-hydrophobic SERS-based LFIA strip was demonstrated by decorating Ag nanoplates with hydrophilic surface onto the specific regions of hydrophobic polymethylmethacrylate (PMMA) film with Raman internal standard (IS), which can unexpectedly inhibit the "coffee-ring phenomenon". The target analytes were consequently enriched in the SERS-active Ag regions by the hydrophobic PMMA, considerably endowing the strip with amended quantitative monitoring ability. Aided by immunoprobes of flower-shaped Ag nanoplates, a limit of detection as 10 pg/mL and an outstanding correlation coefficient value (R2) of 0.992 for carcinoembryonic antigen (CEA) were obtained by utilizing this SERS-based LFIA strip, which can be conducive to clinical monitoring and will broaden the field of vision for the point-of-care diagnostic technique.
Collapse
Affiliation(s)
- Siqi Tang
- Department of Microelectronic Science and Engineering, School of Physical Science and Technology, Ningbo University, Ningbo 315211, Zhejiang, PR China
| | - Hongmei Liu
- Institute of Solid State Physics, Shanxi Datong University, Datong 037009, Shanxi, PR China
| | - Yiran Tian
- Department of Microelectronic Science and Engineering, School of Physical Science and Technology, Ningbo University, Ningbo 315211, Zhejiang, PR China
| | - Dong Chen
- Department of Microelectronic Science and Engineering, School of Physical Science and Technology, Ningbo University, Ningbo 315211, Zhejiang, PR China
| | - Chenjie Gu
- Department of Microelectronic Science and Engineering, School of Physical Science and Technology, Ningbo University, Ningbo 315211, Zhejiang, PR China
| | - Guodong Wei
- Materials Institute of Atomic and Molecular Science, Shanxi University of Science and Technology, Weiyang University Park, Xian 710021, Shanxi, PR China
| | - Tao Jiang
- Department of Microelectronic Science and Engineering, School of Physical Science and Technology, Ningbo University, Ningbo 315211, Zhejiang, PR China.
| | - Jun Zhou
- Department of Microelectronic Science and Engineering, School of Physical Science and Technology, Ningbo University, Ningbo 315211, Zhejiang, PR China
| |
Collapse
|
23
|
Kozik A, Pavlova M, Petrov I, Bychkov V, Kim L, Dorozhko E, Cheng C, Rodriguez RD, Sheremet E. A review of surface-enhanced Raman spectroscopy in pathological processes. Anal Chim Acta 2021; 1187:338978. [PMID: 34753586 DOI: 10.1016/j.aca.2021.338978] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2021] [Revised: 08/18/2021] [Accepted: 08/20/2021] [Indexed: 12/17/2022]
Abstract
With the continuous growth of the human population and new challenges in the quality of life, it is more important than ever to diagnose diseases and pathologies with high accuracy, sensitivity and in different scenarios from medical implants to the operation room. Although conventional methods of diagnosis revolutionized healthcare, alternative analytical methods are making their way out of academic labs into clinics. In this regard, surface-enhanced Raman spectroscopy (SERS) developed immensely with its capability to achieve single-molecule sensitivity and high-specificity in the last two decades, and now it is well on its way to join the arsenal of physicians. This review discusses how SERS is becoming an essential tool for the clinical investigation of pathologies including inflammation, infections, necrosis/apoptosis, hypoxia, and tumors. We critically discuss the strategies reported so far in nanoparticle assembly, functionalization, non-metallic substrates, colloidal solutions and how these techniques improve SERS characteristics during pathology diagnoses like sensitivity, selectivity, and detection limit. Moreover, it is crucial to introduce the most recent developments and future perspectives of SERS as a biomedical analytical method. We finally discuss the challenges that remain as bottlenecks for a routine SERS implementation in the medical room from in vitro to in vivo applications. The review showcases the adaptability and versatility of SERS to resolve pathological processes by covering various experimental and analytical methods and the specific spectral features and analysis results achieved by these methods.
Collapse
Affiliation(s)
- Alexey Kozik
- Tomsk Polytechnic University, Lenin Ave, 30, Tomsk, 634050, Russia; Siberian Medical State University, Moskovskiy Trakt, 2, Tomsk, 634050, Russia
| | - Marina Pavlova
- Tomsk Polytechnic University, Lenin Ave, 30, Tomsk, 634050, Russia; Siberian Medical State University, Moskovskiy Trakt, 2, Tomsk, 634050, Russia
| | - Ilia Petrov
- Tomsk Polytechnic University, Lenin Ave, 30, Tomsk, 634050, Russia
| | - Vyacheslav Bychkov
- Tomsk National Research Medical Center of the Russian Academy of Sciences, Cancer Research Institute, 5 Kooperativny Street, Tomsk, 634009, Russia
| | - Larissa Kim
- Tomsk Polytechnic University, Lenin Ave, 30, Tomsk, 634050, Russia
| | - Elena Dorozhko
- Tomsk Polytechnic University, Lenin Ave, 30, Tomsk, 634050, Russia
| | - Chong Cheng
- College of Polymer Science and Engineering, State Key Laboratory of Polymer Materials Engineering, Sichuan University, Chengdu, 610065, China
| | - Raul D Rodriguez
- Tomsk Polytechnic University, Lenin Ave, 30, Tomsk, 634050, Russia.
| | | |
Collapse
|
24
|
Nagy-Simon T, Hada AM, Suarasan S, Potara M. Recent advances on the development of plasmon-assisted biosensors for detection of C-reactive protein. J Mol Struct 2021; 1246:131178. [DOI: 10.1016/j.molstruc.2021.131178] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2021] [Revised: 07/21/2021] [Accepted: 07/23/2021] [Indexed: 01/02/2023]
|
25
|
Zhao P, Sun J, Zhao S, Song Y, Gao F, Wang H, Ni Q, Wang Y, Sun B. SERS-based immunoassay based on gold nanostars modified with 5,5'-dithiobis-2-nitrobenzoic acid for determination of glial fibrillary acidic protein. Mikrochim Acta 2021; 188:428. [PMID: 34816331 DOI: 10.1007/s00604-021-05081-9] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2021] [Accepted: 10/26/2021] [Indexed: 11/28/2022]
Abstract
A surface-enhanced Raman scattering (SERS)-based immunoassay with gold nanostars (GNSs) is utilized for determination of the subarachnoid hemorrhage (SAH) biomarker glial fibrillary acidic protein (GFAP) at very low concentration levels, which allows for early diagnosis and guides clinical decision-making to treat SAH-induced complications. The Raman reporter 5,5'-dithiobis-2-nitrobenzoic acid (DTNB) modified on GNSs was selected as the SERS tags. The SERS immunoassay was assembled by SERS tag and GFAP probe-immobilized ITO substrate. Therefore, the level of GFAP can be detected by monitoring the characteristic Raman peak intensity of GFAP-conjugated GNSs at 1332 cm-1 with a very low detection limit. Under optimized conditions, the assay can work in the GFAP concentration range from 1 pg⋅mL-1 to 1 μg⋅mL-1, with a detection limit as low as 0.54 fg⋅mL-1. The performance of the SERS immunoassay proven by the detection of GFAP is equivalent to that of the conventional enzyme-linked immunosorbent assay (ELISA). Scheme 1. Schematic illustration of GNSs SERS immunoassay for ultrasensitive dynamic change detection of GFAP. (SAH: Subarachnoid hemorrhage, SCF: Cerebrospinal fluid; GNSs: gold nanostars; SERS: surface-enhanced Raman scattering; GFAP: glial fibrillary acidic protein).
Collapse
Affiliation(s)
- Peng Zhao
- Department of Neurology, Second Affiliated Hospital, Institute for Neurological Research & Key Laboratory of Cerebral Microcirculation, Shandong First Medical University & Shandong Academy of Medical Sciences, Taian, 271000, Shandong, China
| | - Jingyi Sun
- Shandong Provincial Hospital Affiliated To Shandong First Medical University& Shandong Academy of Medical Sciences, Jinan, 250021, Shandong, China
| | - Shijun Zhao
- Department of Neurology, Baotou Central Hospital, Baotou, 014040, Neimenggu, China
| | - Yanan Song
- Qingdao Medical College of Qingdao University, Qingdao, 266021, Shandong, China
| | - Feng Gao
- Department of Neurology, Second Affiliated Hospital, Institute for Neurological Research & Key Laboratory of Cerebral Microcirculation, Shandong First Medical University & Shandong Academy of Medical Sciences, Taian, 271000, Shandong, China
| | - Hongbin Wang
- Department of Neurology, Second Affiliated Hospital, Institute for Neurological Research & Key Laboratory of Cerebral Microcirculation, Shandong First Medical University & Shandong Academy of Medical Sciences, Taian, 271000, Shandong, China
| | - Qingbin Ni
- Postdoctoral Workstation, Taian Central Hospital, Taian, 271000, Shandong, China
| | - Ying Wang
- Department of Neurology, Second Affiliated Hospital, Institute for Neurological Research & Key Laboratory of Cerebral Microcirculation, Shandong First Medical University & Shandong Academy of Medical Sciences, Taian, 271000, Shandong, China.
| | - Baoliang Sun
- Department of Neurology, Second Affiliated Hospital, Institute for Neurological Research & Key Laboratory of Cerebral Microcirculation, Shandong First Medical University & Shandong Academy of Medical Sciences, Taian, 271000, Shandong, China
| |
Collapse
|
26
|
Peroxidase-mimicking nanozyme with surface-dispersed Pt atoms for the colorimetric lateral flow immunoassay of C-reactive protein. Mikrochim Acta 2021; 188:309. [PMID: 34453188 DOI: 10.1007/s00604-021-04968-x] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2021] [Accepted: 07/30/2021] [Indexed: 02/06/2023]
Abstract
Platinum-containing nanozymes with peroxidase-mimicking activity (PMA) have found a broad application in bioanalytical methods and are potentially able to compete with enzymes as the labels. However, traditionally used methods for the synthesis of nanozymes result in only a small fraction of surface-exposed Pt atoms, which participate in catalysis. To overcome this limitation, we propose a new approach for the synthesis of nanozymes with the efficient dispersion of Pt atoms on particles' surfaces. The synthesis of nanozymes includes three steps: the synthesis of gold nanoparticles (Au NPs), the overgrowth of a silver layer over Au NPs (Au@Ag NPs, 6 types of NPs with different thicknesses of Ag shell), and the galvanic replacement of silver with PtCl62- leading to the formation of trimetallic Au@Ag-Pt NPs with uniformly deposited catalytic sites and high Pt-utilization efficiency. Au@Ag-Pt NPs (23 types of NPs with different concentrations of Pt) with various sizes, morphology, optical properties, and PMA were synthesized and comparatively tested. Using energy-dispersive spectroscopy mapping, we confirm the formation of core@shell Au@Ag NPs and dispersion of surface-exposed Pt. The selected Au@Ag-Pt NPs were conjugated with monoclonal antibodies and used as the colorimetric and catalytic labels in lateral flow immunoassay of the inflammation biomarker: C-reactive protein (CRP). The colorimetric signal enhancement was achieved by the oxidation of 3,3'-diaminobenzidine by H2O2 catalyzed by Au@Ag-Pt NPs directly on the test strip. The use of Au@Ag-Pt NPs as the catalytic label produces a 65-fold lower limit of CRP detection in serum (15 pg mL-1) compared with Au NPs and ensures the lowest limit of detection for equipment-free lateral flow immunoassays. The assay shows a high correlation with data of enzyme-linked immunosorbent assay (R2 = 0.986) and high recovery (83.7-116.2%) in serum and plasma. The assay retains all the benefits of lateral flow immunoassay as a point-of-care method.
Collapse
|
27
|
Pang R, Zhu Q, Wei J, Wang Y, Xu F, Meng X, Wang Z. Development of a gold-nanorod-based lateral flow immunoassay for a fast and dual-modal detection of C-reactive protein in clinical plasma samples. RSC Adv 2021; 11:28388-28394. [PMID: 35480760 PMCID: PMC9038069 DOI: 10.1039/d1ra04404d] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2021] [Accepted: 08/05/2021] [Indexed: 12/19/2022] Open
Abstract
Fast and simple detection of C-reactive protein (CRP) is highly significant for the diagnosis and prognosis of inflammatory or infectious diseases. Lateral flow immunoassay has the advantages of rapid detection, simple operation and low cost, but it is usually limited by the quantitative ability and speed of data extraction. Herein, a gold-nanorod-based lateral flow immunoassay was developed to rapidly detect CRP by simultaneously monitoring the colorimetric and temperature signals. In this method, anti-CRP antibody-modified gold nanorods (GNRs) were designed as colorimetric and photothermal conversion probes. A mouse anti-CRP monoclonal antibody and goat anti-mouse IgG were used as test and control lines, respectively. Then, a lateral flow immunochromatographic strip was constructed by a sandwich-type method for detecting CRP by introducing antibody-modified GNRs, and this procedure needed less than 15 min. Finally, the detection signals can be directly observed by eyes and directly read using a thermal imager. The as-synthesized GNR showed high photothermal conversion efficiency (η = 39%) and strong localized surface plasmon resonance (LSPR) absorption. For CRP detection, the proposed immunochromatographic strip exhibited good specificity, high sensitivity, good linearity within the range of 50-10 000 ng mL-1 and a low limit of detection (LOD, 1.3 ng mL-1). This method was successfully applied for CRP detection in clinical plasma samples, and it correlated very well with the diagnostic kit of immunoturbidimetry (r = 0.96). The results indicated that the developed GNR-based immunochromatographic strip has immense potential for use as a rapid and cost-effective in vitro diagnostic kit.
Collapse
Affiliation(s)
- Renzhu Pang
- Department of Thyroid Surgery, The First Hospital of Jilin University Changchun 130021 P. R. China
| | - Qunyan Zhu
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences Changchun 130022 P. R. China
| | - Jia Wei
- Department of Thyroid Surgery, The First Hospital of Jilin University Changchun 130021 P. R. China
| | - Yaoqi Wang
- Department of Thyroid Surgery, The First Hospital of Jilin University Changchun 130021 P. R. China
| | - Fengqin Xu
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences Changchun 130022 P. R. China
- School of Applied Chemical Engineering, University of Science and Technology of China Road Baohe District Hefei 230026 P. R. China
| | - Xianying Meng
- Department of Thyroid Surgery, The First Hospital of Jilin University Changchun 130021 P. R. China
| | - Zhenxin Wang
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences Changchun 130022 P. R. China
- School of Applied Chemical Engineering, University of Science and Technology of China Road Baohe District Hefei 230026 P. R. China
| |
Collapse
|
28
|
Cao X, Song Q, Sun Y, Mao Y, Lu W, Li L. A SERS-LFA biosensor combined with aptamer recognition for simultaneous detection of thrombin and PDGF-BB in prostate cancer plasma. NANOTECHNOLOGY 2021; 32:445101. [PMID: 34298537 DOI: 10.1088/1361-6528/ac1754] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/05/2021] [Accepted: 07/23/2021] [Indexed: 06/13/2023]
Abstract
An innovative surface-enhanced Raman spectroscopy and lateral flow assay (SERS-LFA) biosensor combined with aptamer recognition had been developed for the convenient, rapid, sensitive and accurate detection of thrombin and platelet-derived growth factor-BB (PDGF-BB) associated with prostate cancer simultaneously. During the biosensor operation, thrombin and PDGF-BB in the sample were recognized and combined by thiol-modified aptamers immobilized on Au-Ag hollow nanoparticles (Au-Ag HNPs) surface and biotinylated aptamers immobilized on the test lines of the biosensor. Thus, thrombin and PDGF-BB were simultaneously captured between detection aptamers and capture aptamers in a sandwich structure. Finite difference time domain simulation confirmed that 'hot spots' appeared at the gaps of Au-Ag HNPs dimer in the enhanced electromagnetic field compared to that of a single Au-Ag HNP, indicating that the aggregated Au-Ag HNPs owned a good SERS signal amplification effect. The detection limits of thrombin and PDGF-BB in human plasma were as low as 4.837 pg ml-1and 3.802 pg ml-1, respectively. Moreover, the accuracy of the biosensor which was applied to detect thrombin and PDGF-BB in prostate cancer plasma had been verified. This designed biosensor had broad application prospects in the clinical diagnosis of prostate cancer.
Collapse
Affiliation(s)
- Xiaowei Cao
- Institute of Translational Medicine, Medical College, Yangzhou University, Yangzhou, People's Republic of China
- Jiangsu Key Laboratory of Integrated Traditional Chinese and Western Medicine for Prevention and Treatment of Senile Diseases, Yangzhou University, Yangzhou, People's Republic of China
- Jiangsu Key Laboratory of Experimental & Translational Noncoding RNA Research, Medical College, Yangzhou University, Yangzhou, People's Republic of China
| | - Qilong Song
- Institute of Translational Medicine, Medical College, Yangzhou University, Yangzhou, People's Republic of China
- Jiangsu Key Laboratory of Integrated Traditional Chinese and Western Medicine for Prevention and Treatment of Senile Diseases, Yangzhou University, Yangzhou, People's Republic of China
- Jiangsu Key Laboratory of Experimental & Translational Noncoding RNA Research, Medical College, Yangzhou University, Yangzhou, People's Republic of China
| | - Yue Sun
- Institute of Translational Medicine, Medical College, Yangzhou University, Yangzhou, People's Republic of China
- Jiangsu Key Laboratory of Integrated Traditional Chinese and Western Medicine for Prevention and Treatment of Senile Diseases, Yangzhou University, Yangzhou, People's Republic of China
- Jiangsu Key Laboratory of Experimental & Translational Noncoding RNA Research, Medical College, Yangzhou University, Yangzhou, People's Republic of China
| | - Yu Mao
- Institute of Translational Medicine, Medical College, Yangzhou University, Yangzhou, People's Republic of China
- Jiangsu Key Laboratory of Integrated Traditional Chinese and Western Medicine for Prevention and Treatment of Senile Diseases, Yangzhou University, Yangzhou, People's Republic of China
- Jiangsu Key Laboratory of Experimental & Translational Noncoding RNA Research, Medical College, Yangzhou University, Yangzhou, People's Republic of China
| | - Wenbo Lu
- Shanxi Normal University, College of Chemistry and Material Science, Linfen, 041004, People's Republic of China
| | - Li Li
- Children's Hospital of Nanjing Medical University, Nanjing, People's Republic of China
| |
Collapse
|
29
|
Desai RI, Kangas BD, Limoli CL. Nonhuman primate models in the study of spaceflight stressors: Past contributions and future directions. LIFE SCIENCES IN SPACE RESEARCH 2021; 30:9-23. [PMID: 34281669 DOI: 10.1016/j.lssr.2021.03.008] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/15/2021] [Revised: 03/28/2021] [Accepted: 03/31/2021] [Indexed: 06/13/2023]
Abstract
Studies in rodents suggest that exposure to distinct spaceflight stressors (e.g., space radiation, isolation/confinement, microgravity) may have a profound impact on an astronaut's ability to perform both simple and complex tasks related to neurocognitive performance, central nervous system (CNS) and vestibular/sensorimotor function. However, limited information is currently available on how combined exposure to the spaceflight stressors will impact CNS-related neurocognitive and neurobiological function in-flight and, as well, terrestrial risk of manifesting neurodegenerative conditions when astronauts return to earth. This information gap has significantly hindered our ability to realistically estimate spaceflight hazard risk to the CNS associated with deep space exploration. Notwithstanding a significant body of work with rodents, there have been very few direct investigations of the impact of these spaceflight stressors in combination and, to our knowledge, no such investigations using nonhuman primate (NHP) animal models. In view of the widely-recognized translational value of NHP data in advancing biomedical discoveries, this research deficiency limits our understanding regarding the impact of individual and combined spaceflight stressors on CNS-related neurobiological function. In this review, we address this knowledge gap by conducting a systematic and comprehensive evaluation of existing research on the impact of exposure to spaceflight stressors on NHP CNS-related function. This review is structured to: a) provide an overarching view of the past contributions of NHPs to spaceflight research as well as the strengths, limitations, and translational value of NHP research in its own right and within the existing context of NASA-relevant rodent research; b) highlight specific conclusions based on the published literature and areas needed for future endeavors; c) describe critical research gaps and priorities in NHP research to facilitate NASA's efforts to bridge the key knowledge gaps that currently exist in translating rodent data to humans; and d) provide a roadmap of recommendations for NASA regarding the availability, validity, strengths, and limitations of various NHP models for future targeted research.
Collapse
Affiliation(s)
- Rajeev I Desai
- Department of Psychiatry, Harvard Medical School, Boston, MA, USA.
| | - Brian D Kangas
- Department of Psychiatry, Harvard Medical School, Boston, MA, USA
| | - Charles L Limoli
- Department of Radiation Oncology, University of California, Irvine, CA, USA
| |
Collapse
|
30
|
Li Y, Liu X, Guo J, Zhang Y, Guo J, Wu X, Wang B, Ma X. Simultaneous Detection of Inflammatory Biomarkers by SERS Nanotag-Based Lateral Flow Assay with Portable Cloud Raman Spectrometer. NANOMATERIALS (BASEL, SWITZERLAND) 2021; 11:1496. [PMID: 34198765 PMCID: PMC8226521 DOI: 10.3390/nano11061496] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/16/2021] [Revised: 05/29/2021] [Accepted: 05/31/2021] [Indexed: 01/22/2023]
Abstract
Inflammatory biomarkers are closely related to infectious diseases. However, traditional clinical tests of laboratory inspection are unable to achieve rapid and accurate detection of these biomarkers on-site due to shortcomings such as complex experimental operation, expensive equipment, and long test time. Herein, we proposed a lateral flow assay (LFA) strip based on surface-enhanced Raman scattering (SERS) nanotags (SERS-LFA strips) for the simultaneous and quantitative detection of dual infection biomarkers, serum amyloid A (SAA) and C-reactive protein (CRP), respectively. In practice, mesoporous silica (mSiO2)-coated Au nanoparticles (Au NPs) were used as the SERS substrate. Mercaptobenzoic acid (MBA) was embedded in the internal gap between Au NPs and the mSiO2 shell to prepare AuMBA@mSiO2 NPs, onto which SAA and CRP antibodies were modified to prepare two AuMBA@mSiO2 SERS nanotags. The Raman intensities of the test and control lines were simultaneously identified for the qualitative detection of SAA and CRP, with limits of detection (LODs) as low as 0.1 and 0.05 ng/mL for SAA and CRP, respectively. Finally, aiming at point-of-care testing (POCT) applications, we used a smartphone-based portable Raman spectrometer to quantitatively analyze the SERS-LFA strips. The Raman signal could still be accurately detected when the concentration of SAA and CRP was 10 ng/mL, which is lower than the LOD required in clinical practice for most diseases. Therefore, taking into account its simple operation and short analysis time, by using a portable Raman spectrometer which can be equipped with a 5G cloud-based healthcare management system, the current strategy based on SERS-LFA provides the potential for the quick and on-site diagnosis of infectious diseases such as sepsis, which is of great significance for medical guidance on the treatment of widely spread infection-related diseases in remote areas that lack well-developed medical resources.
Collapse
Affiliation(s)
- Yang Li
- School of Materials Engineering, Shanghai University of Engineering Science, Shanghai 201620, China; (Y.L.); (Y.Z.)
| | - Xiaojia Liu
- Sauvage Laboratory for Smart Materials, School of Materials Science and Engineering, Harbin Institute of Technology (Shenzhen), Shenzhen 518055, China;
- Shenzhen Bay Laboratory, No. 9 Duxue Road, Shenzhen 518055, China
| | - Jiuchuan Guo
- School of Communication and Information Engineering, University of Electronic Science and Technology of China, Chengdu 611731, China; (J.G.); (J.G.)
| | - Yueting Zhang
- School of Materials Engineering, Shanghai University of Engineering Science, Shanghai 201620, China; (Y.L.); (Y.Z.)
| | - Jinhong Guo
- School of Communication and Information Engineering, University of Electronic Science and Technology of China, Chengdu 611731, China; (J.G.); (J.G.)
| | - Xinggui Wu
- CloudMinds Inc., Shenzhen Bay Science and Technology Ecological Park, Shenzhen 100022, China
| | - Bo Wang
- School of Materials Engineering, Shanghai University of Engineering Science, Shanghai 201620, China; (Y.L.); (Y.Z.)
| | - Xing Ma
- Sauvage Laboratory for Smart Materials, School of Materials Science and Engineering, Harbin Institute of Technology (Shenzhen), Shenzhen 518055, China;
- Shenzhen Bay Laboratory, No. 9 Duxue Road, Shenzhen 518055, China
| |
Collapse
|
31
|
Hong D, Kim K, Jo EJ, Kim MG. Electrochemiluminescence-Incorporated Lateral Flow Immunosensors Using Ru(bpy) 32+-Labeled Gold Nanoparticles for the Full-Range Detection of Physiological C-Reactive Protein Levels. Anal Chem 2021; 93:7925-7932. [PMID: 34032406 DOI: 10.1021/acs.analchem.1c00623] [Citation(s) in RCA: 40] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
C-reactive protein (CRP) is used as a general biomarker for inflammation and infection. During stroke and myocardial infarction, CRP increases and is present in a broad concentration range of 1-500 μg/mL. Therefore, full-range CRP detection is crucial to identify patients who need close follow-up or intensive treatment after a heart attack. Here, we report the first attempt to develop an electrochemiluminescent lateral flow immunosensor (ECL-LFI) that allows full-range CRP detection. Ru(bpy)32+-labeled gold nanoparticles (AuNPs) are used as a CRP-targeting probe and a signal generator; they form sandwich immunocomplexes at the test line of the strip and generate strong ECL emission via a Ru(bpy)32+/tripropylamine system. The ECL-LFI shows high sensitivity in detecting CRP in spiked serum, with a limit of detection of 4.6 pg/mL within 15 min, and a broad detection range of 0.01-1000 ng/mL, which is 2 orders of magnitude broader than that of conventional colorimetric LFI. The clinical usability of the ECL-LFI was evaluated using 30 clinical serum samples (200 ng/mL to 5 mg/mL), which showed a good linear correlation (R2 = 0.9896), with a clinical chemistry analyzer. The results suggest that the ECL-LFI holds great potential for CRP detection in point-of-care diagnostics.
Collapse
Affiliation(s)
- Donggu Hong
- Department of Chemistry, School of Physics and Chemistry, Gwangju Institute of Science and Technology (GIST), 123 Cheomdan-gwagiro, Buk-gu, Gwangju 61005, Republic of Korea
| | - Kihyeun Kim
- Department of Chemistry, School of Physics and Chemistry, Gwangju Institute of Science and Technology (GIST), 123 Cheomdan-gwagiro, Buk-gu, Gwangju 61005, Republic of Korea
| | - Eun-Jung Jo
- Department of Chemistry, School of Physics and Chemistry, Gwangju Institute of Science and Technology (GIST), 123 Cheomdan-gwagiro, Buk-gu, Gwangju 61005, Republic of Korea
| | - Min-Gon Kim
- Department of Chemistry, School of Physics and Chemistry, Gwangju Institute of Science and Technology (GIST), 123 Cheomdan-gwagiro, Buk-gu, Gwangju 61005, Republic of Korea
| |
Collapse
|
32
|
Wang L, Wang X, Cheng L, Ding S, Wang G, Choo J, Chen L. SERS-based test strips: Principles, designs and applications. Biosens Bioelectron 2021; 189:113360. [PMID: 34051383 DOI: 10.1016/j.bios.2021.113360] [Citation(s) in RCA: 88] [Impact Index Per Article: 22.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2020] [Revised: 05/10/2021] [Accepted: 05/16/2021] [Indexed: 10/21/2022]
Abstract
Test strips represent a class of point-of-care testing (POCT) tools for analysis of a variety of biomarkers towards diagnostics. Conventional test strips offer benefits of simple operation, visualization, and short detection time, along with the drawbacks of relatively low sensitivity and unavailability of quantitative analysis. Recently, the combination of surface-enhanced Raman scattering (SERS) and test strips have evolved to provide a powerful platform capable of ultrasensitive and multiplex detection of extensive analytes of interest. In this review, we focus on the working principles, design strategies and POCT applications of SERS-based test strips. Initially, both lateral and vertical flow test strips are briefly introduced, followed by presentation of various strategies for reforming SERS-based test strips with better detection performance. Applications of SERS-based test strips in diagnosis of disease biomarkers, nucleic acids and toxins are reviewed, with an emphasis on SERS tag design, sensitivity and analytical applicability. Finally, conclusions are made and perspectives on futuristic research directions are given.
Collapse
Affiliation(s)
- Luyang Wang
- College of Food Science and Engineering, Ocean University of China, 5 Yushan Road, Qingdao, 266003, China
| | - Xiaokun Wang
- Shandong Provincial Key Laboratory of Biochemical Engineering, College of Marine Science and Biological Engineering, Qingdao University of Science and Technology, Qingdao, 266042, China
| | - Lu Cheng
- College of Food Science and Engineering, Ocean University of China, 5 Yushan Road, Qingdao, 266003, China
| | - Shansen Ding
- College of Food Science and Engineering, Ocean University of China, 5 Yushan Road, Qingdao, 266003, China
| | - Guoqing Wang
- College of Food Science and Engineering, Ocean University of China, 5 Yushan Road, Qingdao, 266003, China; Laboratory for Marine Drugs and Bioproducts of Qingdao National Laboratory for Marine Science and Technology, Qingdao, 266237, China.
| | - Jaebum Choo
- Department of Chemistry, Chung-Ang University, Seoul, 06974, South Korea.
| | - Lingxin Chen
- CAS Key Laboratory of Coastal Environmental Processes and Ecological Remediation, Shandong Key Laboratory of Coastal Environmental Processes, Yantai Institute of Coastal Zone Research, Chinese Academy of Sciences, Yantai, 264003, China; College of Chemistry and Chemical Engineering, Qufu Normal University, Qufu, 273165, China.
| |
Collapse
|
33
|
Noh S, Kim J, Kim G, Park C, Jang H, Lee M, Lee T. Recent Advances in CRP Biosensor Based on Electrical, Electrochemical and Optical Methods. SENSORS 2021; 21:s21093024. [PMID: 33925825 PMCID: PMC8123455 DOI: 10.3390/s21093024] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/10/2021] [Revised: 04/13/2021] [Accepted: 04/22/2021] [Indexed: 12/12/2022]
Abstract
C-reactive protein (CRP) is an acute-phase reactive protein that appears in the bloodstream in response to inflammatory cytokines such as interleukin-6 produced by adipocytes and macrophages during the acute phase of the inflammatory/infectious process. CRP measurement is widely used as a representative acute and chronic inflammatory disease marker. With the development of diagnostic techniques measuring CRP more precisely than before, CRP is being used not only as a traditional biomarker but also as a biomarker for various diseases. The existing commercialized CRP assays are dominated by enzyme-linked immunosorbent assay (ELISA). ELISA has high selectivity and sensitivity, but its limitations include requiring complex analytic processes, long analysis times, and professional manpower. To overcome these problems, nanobiotechnology is able to provide alternative diagnostic tools. By introducing the nanobio hybrid material to the CRP biosensors, CRP can be measured more quickly and accurately, and highly sensitive biosensors can be used as portable devices. In this review, we discuss the recent advancements in electrochemical, electricity, and spectroscopy-based CRP biosensors composed of biomaterial and nanomaterial hybrids.
Collapse
Affiliation(s)
- Seungwoo Noh
- Department of Chemical Engineering, Kwangwoon University, Seoul 01897, Korea; (S.N.); (J.K.); (G.K.); (C.P.)
| | - Jinmyeong Kim
- Department of Chemical Engineering, Kwangwoon University, Seoul 01897, Korea; (S.N.); (J.K.); (G.K.); (C.P.)
| | - Gahyeon Kim
- Department of Chemical Engineering, Kwangwoon University, Seoul 01897, Korea; (S.N.); (J.K.); (G.K.); (C.P.)
| | - Chulhwan Park
- Department of Chemical Engineering, Kwangwoon University, Seoul 01897, Korea; (S.N.); (J.K.); (G.K.); (C.P.)
| | - Hongje Jang
- Department of Chemistry, Kwangwoon University, 20 Kwangwoon-Ro, Nowon-Gu, Seoul 01897, Korea;
| | - Minho Lee
- School of Integrative Engineering, Chung-Ang University, Seoul 06974, Korea
- Correspondence: (M.L.); (T.L.); Tel.: +82-2-820-8320 (M.L.); +82-2-940-5771 (T.L.)
| | - Taek Lee
- Department of Chemical Engineering, Kwangwoon University, Seoul 01897, Korea; (S.N.); (J.K.); (G.K.); (C.P.)
- Correspondence: (M.L.); (T.L.); Tel.: +82-2-820-8320 (M.L.); +82-2-940-5771 (T.L.)
| |
Collapse
|
34
|
Competitive immunosensor for sensitive and optical anti-interference detection of imidacloprid by surface-enhanced Raman scattering. Food Chem 2021; 358:129898. [PMID: 33933961 DOI: 10.1016/j.foodchem.2021.129898] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2020] [Revised: 04/04/2021] [Accepted: 04/16/2021] [Indexed: 11/23/2022]
Abstract
The sensitive detection of pesticides in complex environment is important but still challenging in presence of organic-rich water sample and food matrix. Herein, we reported a nitrile-mediated SERS immunosensor for sensitive and optical anti-interference determination of imidacloprid. Raman tag contained CN bond could provide a sharp characteristic peak in the Raman-silent spectral window (1800 ~ 2800 cm-1), which could resist the optical noises from the fingerprint region (<1800 cm-1). Aucore-Agshell bimetallic nanocuboid (AuNR@Ag) connected with antigen and Raman tag was used as Raman probe, while Fe3O4 magnetic nanoparticle functionalized with anti-imidacloprid antibody was applied as signal enhancer. Owing to the specific recognition ability between antigen and antibody, the competitive system with imidacloprid was formed. Under the optimal condition, the linear relationship was developed in the range of 10-400 nM. Finally, the SERS immunosensor was successfully applied to determine imidacloprid in real samples with recoveries from 96.8% to 100.5%.
Collapse
|
35
|
Yadav S, Sadique MA, Ranjan P, Kumar N, Singhal A, Srivastava AK, Khan R. SERS Based Lateral Flow Immunoassay for Point-of-Care Detection of SARS-CoV-2 in Clinical Samples. ACS APPLIED BIO MATERIALS 2021; 4:2974-2995. [PMID: 35014387 PMCID: PMC7986978 DOI: 10.1021/acsabm.1c00102] [Citation(s) in RCA: 91] [Impact Index Per Article: 22.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2021] [Accepted: 03/04/2021] [Indexed: 12/13/2022]
Abstract
The current scenario, an ongoing pandemic of COVID-19, places a dreadful burden on the healthcare system worldwide. Subsequently, there is a need for a rapid, user-friendly, and inexpensive on-site monitoring system for diagnosis. The early and rapid diagnosis of SARS-CoV-2 plays an important role in combating the outbreak. Although conventional methods such as PCR, RT-PCR, and ELISA, etc., offer a gold-standard solution to manage the pandemic, they cannot be implemented as a point-of-care (POC) testing arrangement. Moreover, surface-enhanced Raman spectroscopy (SERS) having a high enhancement factor provides quantitative results with high specificity, sensitivity, and multiplex detection ability but lacks in POC setup. In contrast, POC devices such as lateral flow immunoassay (LFIA) offer rapid, simple-to-use, cost-effective, reliable platform. However, LFIA has limitations in quantitative and sensitive analyses of SARS-CoV-2 detection. To resolve these concerns, herein we discuss a unique modality that is an integration of SERS with LFIA for quantitative analyses of SARS-CoV-2. The miniaturization ability of SERS-based devices makes them promising in biosensor application and has the potential to make a better alternative of conventional diagnostic methods. This review also demonstrates the commercially available and FDA/ICMR approved LFIA kits for on-site diagnosis of SARS-CoV-2.
Collapse
Affiliation(s)
- Shalu Yadav
- Microfluidics & MEMS Centre,
CSIR−Advanced Materials and Processes Research Institute
(AMPRI), Hoshangabad Road, Bhopal 462026, India
- Academy of Scientific and Innovative Research
(AcSIR), Ghaziabad 201002, India
| | - Mohd. Abubakar Sadique
- Microfluidics & MEMS Centre,
CSIR−Advanced Materials and Processes Research Institute
(AMPRI), Hoshangabad Road, Bhopal 462026, India
| | - Pushpesh Ranjan
- Microfluidics & MEMS Centre,
CSIR−Advanced Materials and Processes Research Institute
(AMPRI), Hoshangabad Road, Bhopal 462026, India
- Academy of Scientific and Innovative Research
(AcSIR), Ghaziabad 201002, India
| | - Neeraj Kumar
- Microfluidics & MEMS Centre,
CSIR−Advanced Materials and Processes Research Institute
(AMPRI), Hoshangabad Road, Bhopal 462026, India
- Academy of Scientific and Innovative Research
(AcSIR), Ghaziabad 201002, India
| | - Ayushi Singhal
- Microfluidics & MEMS Centre,
CSIR−Advanced Materials and Processes Research Institute
(AMPRI), Hoshangabad Road, Bhopal 462026, India
- Academy of Scientific and Innovative Research
(AcSIR), Ghaziabad 201002, India
| | - Avanish K. Srivastava
- Microfluidics & MEMS Centre,
CSIR−Advanced Materials and Processes Research Institute
(AMPRI), Hoshangabad Road, Bhopal 462026, India
| | - Raju Khan
- Microfluidics & MEMS Centre,
CSIR−Advanced Materials and Processes Research Institute
(AMPRI), Hoshangabad Road, Bhopal 462026, India
- Academy of Scientific and Innovative Research
(AcSIR), Ghaziabad 201002, India
| |
Collapse
|
36
|
A sensitive and quantitative prognosis of C-reactive protein at picogram level using mesoporous silica encapsulated core-shell up-conversion nanoparticle based lateral flow strip assay. Talanta 2021; 230:122335. [PMID: 33934788 DOI: 10.1016/j.talanta.2021.122335] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2021] [Revised: 03/12/2021] [Accepted: 03/18/2021] [Indexed: 12/13/2022]
Abstract
C- reactive protein (CRP) is a sensitive indicator for infectious or inflammatory diseases in human which can reflect the body's inflammation latency and early pathophysiological changes. The most common detection method of serum CRP is ELISA that has been proved to be expensive and time-consuming, restricting its use in point-of-care application. In this paper, we demonstrated a lateral flow system for CRP quantification by using mesoporous silica (mSiO2) coated up-converting nanoparticles (UCNPs) (denoted as UCNPs@mSiO2) as fluorescent labels. The up-converting core can emit strong green fluorescence signals under NIR excitation light (980 nm) with excellent photostability, high signal-to-noise ratio and low background fluorescence. By wrapping ultrathin mSiO2 outside, the core-shell structured UCNPs@mSiO2 exhibits good dispersity and stability meanwhile maintains strong fluorescence emission. Besides, the mSiO2 shell provides further functionalities for antibody linkage. By using a portable fluorescence sensor, we reached a CRP detection limit of 0.05 ng/mL and a linear range from 0.1 ng/mL-50 ng/mL, and the detection time was no more than 8 min. The lateral flow test strips exhibit great stability in CRP quantification (CV%<5) and have a life time of more than 1 week at ambient temperature. Furthermore, the proposed system can work with a cloud-enabled smartphone through Bluetooth for Internet of Medical Things application. This CRP detection method proves to be rapid and easy-operated, which has great potential in early inflammatory disease perception in the point-of-care tests and future's 5G-enabled remote healthcare management.
Collapse
|
37
|
Frimpong R, Jang W, Kim JH, Driskell JD. Rapid vertical flow immunoassay on AuNP plasmonic paper for SERS-based point of need diagnostics. Talanta 2021; 223:121739. [DOI: 10.1016/j.talanta.2020.121739] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2020] [Revised: 09/22/2020] [Accepted: 10/04/2020] [Indexed: 01/09/2023]
|
38
|
Khlebtsov B, Khlebtsov N. Surface-Enhanced Raman Scattering-Based Lateral-Flow Immunoassay. NANOMATERIALS (BASEL, SWITZERLAND) 2020; 10:E2228. [PMID: 33182579 PMCID: PMC7696391 DOI: 10.3390/nano10112228] [Citation(s) in RCA: 38] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/15/2020] [Revised: 11/06/2020] [Accepted: 11/07/2020] [Indexed: 12/13/2022]
Abstract
Lateral flow immunoassays (LFIAs) have been developed and used in a wide range of applications, in point-of-care disease diagnoses, environmental safety, and food control. However, in its classical version, it has low sensitivity and can only perform semiquantitative detection, based on colorimetric signals. Over the past decade, surface-enhanced Raman scattering (SERS) tags have been developed in order to decrease the detection limit and enable the quantitative analysis of analytes. Of note, these tags needed new readout systems and signal processing algorithms, while the LFIA design remained unchanged. This review highlights SERS strategies of signal enhancement for LFIAs. The types of labels used, the possible gain in sensitivity from their use, methods of reading and processing the signal, and the prospects for use are discussed.
Collapse
Affiliation(s)
- Boris Khlebtsov
- Institute of Biochemistry and Physiology of Plants and Microorganisms, Russian Academy of Sciences, 410049 Saratov, Russia;
| | - Nikolai Khlebtsov
- Institute of Biochemistry and Physiology of Plants and Microorganisms, Russian Academy of Sciences, 410049 Saratov, Russia;
- Faculty of Nano- and Biomedical Technologies, Saratov State University, 410012 Saratov, Russia
| |
Collapse
|
39
|
Shi L, Xu L, Xiao R, Zhou Z, Wang C, Wang S, Gu B. Rapid, Quantitative, High-Sensitive Detection of Escherichia coli O157:H7 by Gold-Shell Silica-Core Nanospheres-Based Surface-Enhanced Raman Scattering Lateral Flow Immunoassay. Front Microbiol 2020; 11:596005. [PMID: 33240250 PMCID: PMC7677456 DOI: 10.3389/fmicb.2020.596005] [Citation(s) in RCA: 28] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2020] [Accepted: 10/15/2020] [Indexed: 11/13/2022] Open
Abstract
Escherichia coli O157:H7 is regarded as one of the most harmful pathogenic microorganisms related to foodborne diseases. This paper proposes a rapid-detection biosensor for the sensitive and quantitative analysis of E. coli O157:H7 in biological samples by surface-enhanced Raman scattering (SERS)-based lateral flow immunoassay (LFIA). A novel gold-shell silica-core (SiO2/Au) nanosphere (NP) with monodispersity, good stability, and excellent SERS activity was utilized to prepare high-performance tags for the SERS-based LFIA system. The SiO2/Au SERS tags, which were modified with two layers of Raman reporter molecules and monoclonal antibodies, effectively bind with E. coli O157:H7 and form sandwich immune complexes on the test lines. E. coli O157:H7 was quantitatively detected easily by detecting the Raman intensity of the test lines. Under optimal conditions, the limit of detection (LOD) of the SiO2/Au-based SERS-LIFA strips for the target bacteria was 50 cells/mL in PBS solution, indicating these strips are 2,000 times more sensitive than colloidal Au-based LFIA strips. Moreover, the proposed assay demonstrated high applicability in E. coli O157:H7 detection in biological samples, including tap water, milk, human urine, lettuce extract and beef, with a low LOD of 100 cells/mL. Results indicate that the proposed SERS-based LFIA strip is applicable for the sensitive and quantitative determination of E. coli O157:H7.
Collapse
Affiliation(s)
- Luoluo Shi
- Medical Technology Institute of Xuzhou Medical University, Xuzhou, China
- Beijing Institute of Radiation Medicine, Beijing, China
- Department of Laboratory Medicine, Affiliated Hospital of Xuzhou Medical University, Xuzhou, China
| | - Ling Xu
- Medical Technology Institute of Xuzhou Medical University, Xuzhou, China
- Department of Laboratory Medicine, Affiliated Hospital of Xuzhou Medical University, Xuzhou, China
| | - Rui Xiao
- Beijing Institute of Radiation Medicine, Beijing, China
| | - Zihui Zhou
- College of Life Sciences, Anhui Agricultural University, Hefei, China
| | - Chongwen Wang
- Medical Technology Institute of Xuzhou Medical University, Xuzhou, China
- Beijing Institute of Radiation Medicine, Beijing, China
- College of Life Sciences, Anhui Agricultural University, Hefei, China
| | - Shengqi Wang
- Beijing Institute of Radiation Medicine, Beijing, China
| | - Bing Gu
- Medical Technology Institute of Xuzhou Medical University, Xuzhou, China
- Department of Laboratory Medicine, Affiliated Hospital of Xuzhou Medical University, Xuzhou, China
| |
Collapse
|
40
|
Yang X, Liu X, Gu B, Liu H, Xiao R, Wang C, Wang S. Quantitative and simultaneous detection of two inflammation biomarkers via a fluorescent lateral flow immunoassay using dual-color SiO 2@QD nanotags. Mikrochim Acta 2020; 187:570. [PMID: 32939582 DOI: 10.1007/s00604-020-04555-6] [Citation(s) in RCA: 32] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2020] [Accepted: 09/07/2020] [Indexed: 12/12/2022]
Abstract
An on-site detection strategy is reported based on dual-color SiO2@quantum dot (QD)-integrated lateral flow immunoassay (LFA) strip to realize the quantitative and simultaneous detection of C-reactive protein (CRP) and procalcitonin (PCT) in serum. The dual-color SiO2@QD nanotags with monodispersity and excellent luminescence were synthesized using polyethyleneimine-mediated electrostatic adsorption of dense red CdSe/ZnS-COOH (excitation/emission 365/625 nm) or green CdSe/ZnS-COOH (excitation/emission 365/525 nm) QDs on the surface of 180 nm SiO2 spheres and were conjugated with anti-PCT and anti-CRP monoclonal antibodies, as stable and fluorescent-enhanced QD nanotags in the LFA system. The use of SiO2@QDs with two different fluorescent signals caused the sensitivity and specificity of the multiplex LFA system. As a result, the proposed assay provided a wide logarithmic determination range with a CRP quantitative range of 0.5-103 ng/mL and PCT quantitative range of 0.05-103 ng/mL. The limits of detection (LODs) of CRP and PCT reached 0.5 and 0.05 ng/mL, respectively. The SiO2@QD-based LFA showed great potential as rapid detection tool for the simultaneous monitoring of CRP and PCT in serum sample.
Collapse
Affiliation(s)
- Xingsheng Yang
- College of Life Sciences, Anhui Agricultural University, Hefei, 230036, People's Republic of China.,Beijing Institute of Radiation Medicine, Beijing, 100850, People's Republic of China
| | - Xiaoxian Liu
- College of Life Sciences, Anhui Agricultural University, Hefei, 230036, People's Republic of China.,Beijing Institute of Radiation Medicine, Beijing, 100850, People's Republic of China
| | - Bing Gu
- Medical Technology Institute of Xuzhou Medical University, Xuzhou, 221004, People's Republic of China.,Department of Laboratory Medicine, Affiliated Hospital of Xuzhou Medical University, Xuzhou, 221004, People's Republic of China
| | - Haifeng Liu
- College of Life Sciences, Anhui Agricultural University, Hefei, 230036, People's Republic of China.,Beijing Institute of Radiation Medicine, Beijing, 100850, People's Republic of China
| | - Rui Xiao
- Beijing Institute of Radiation Medicine, Beijing, 100850, People's Republic of China.
| | - Chongwen Wang
- College of Life Sciences, Anhui Agricultural University, Hefei, 230036, People's Republic of China. .,Beijing Institute of Radiation Medicine, Beijing, 100850, People's Republic of China. .,Medical Technology Institute of Xuzhou Medical University, Xuzhou, 221004, People's Republic of China.
| | - Shengqi Wang
- Beijing Institute of Radiation Medicine, Beijing, 100850, People's Republic of China.
| |
Collapse
|
41
|
Yan S, Liu C, Fang S, Ma J, Qiu J, Xu D, Li L, Yu J, Li D, Liu Q. SERS-based lateral flow assay combined with machine learning for highly sensitive quantitative analysis of Escherichia coli O157:H7. Anal Bioanal Chem 2020; 412:7881-7890. [DOI: 10.1007/s00216-020-02921-0] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2020] [Revised: 08/13/2020] [Accepted: 08/27/2020] [Indexed: 10/23/2022]
|
42
|
Ye H, Liu Y, Zhan L, Liu Y, Qin Z. Signal amplification and quantification on lateral flow assays by laser excitation of plasmonic nanomaterials. Theranostics 2020; 10:4359-4373. [PMID: 32292500 PMCID: PMC7150487 DOI: 10.7150/thno.44298] [Citation(s) in RCA: 52] [Impact Index Per Article: 10.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2020] [Accepted: 02/23/2020] [Indexed: 12/14/2022] Open
Abstract
Lateral flow assay (LFA) has become one of the most widely used point-of-care diagnostic methods due to its simplicity and low cost. While easy to use, LFA suffers from its low sensitivity and poor quantification, which largely limits its applications for early disease diagnosis and requires further testing to eliminate false-negative results. Over the past decade, signal enhancement strategies that took advantage of the laser excitation of plasmonic nanomaterials have pushed down the detection limit and enabled quantification of analytes. Significantly, these methods amplify the signal based on the current LFA design without modification. This review highlights these strategies of signal enhancement for LFA including surface enhanced Raman scattering (SERS), photothermal and photoacoustic methods. Perspectives on the rational design of the reader systems are provided. Future translation of the research toward clinical applications is also discussed.
Collapse
Affiliation(s)
- Haihang Ye
- Department of Mechanical Engineering, University of Texas at Dallas, Richardson, Texas 75080, USA
| | - Yaning Liu
- Department of Mechanical Engineering, University of Texas at Dallas, Richardson, Texas 75080, USA
| | - Li Zhan
- Department of Mechanical Engineering, University of Minnesota, 111 Church Street SE, Minneapolis, Minnesota 55455, USA
| | - Yilin Liu
- Department of Mechanical Engineering, University of Minnesota, 111 Church Street SE, Minneapolis, Minnesota 55455, USA
| | - Zhenpeng Qin
- Department of Mechanical Engineering, University of Texas at Dallas, Richardson, Texas 75080, USA
- Department of Bioengineering, University of Texas at Dallas, Richardson, Texas 75080, USA
- Center for Advanced Pain Studies, University of Texas at Dallas, Richardson, Texas 75080, USA
- Department of Surgery, The University of Texas Southwestern Medical Center, 5323 Harry Lines Blvd, Dallas, Texas 75390, USA
| |
Collapse
|
43
|
Yun BJ, Koh WG. Highly-sensitive SERS-based immunoassay platform prepared on silver nanoparticle-decorated electrospun polymeric fibers. J IND ENG CHEM 2020. [DOI: 10.1016/j.jiec.2019.10.032] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
44
|
Zhang P, Liu G, Feng S, Zhou X, Xu W, Cai W. Engineering of flexible granular Au nanocap ordered array and its surface enhanced Raman spectroscopy effect. NANOTECHNOLOGY 2020; 31:035303. [PMID: 31550688 DOI: 10.1088/1361-6528/ab477c] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
Surface enhanced Raman spectroscopy (SERS) is a new and developing analytical technology in chemical and biological detection. However, traditional hard SERS substrates are struggling to meet the growing demand for flexible devices. In this work, we introduce a simple, cost-effective and large scale preparation route to form a flexible Au nanocap (AuNC) ordered array as SERS substrates via reactive ion etching (RIE) method and then Au deposition. We find RIE is an excellent method for nanoroughening the surface of polystyrene (PS) spheres. Such flexible SERS substrates exhibit high sensitivity and uniformity for detecting organic molecules. The finite-difference time-domain simulation results revealed that a strong electric field coupling effect existed not only in the gap site between the Au nanoparticles (AuNPs), but also in the connection position between the AuNCs and the single AuNP. This study not only offers a novel way for nanoroughening of PS spheres, but also acquires flexible and cheap SERS substrates for quick and sensitive detection of organic molecules.
Collapse
Affiliation(s)
- Peng Zhang
- Key Lab of Materials Physics, Anhui Key Lab of Nanomaterials and Nanotechnology, Institute of Solid State Physics, Chinese Academy of Sciences, Hefei 230031, People's Republic of China. University of Science and Technology of China, Hefei 230026, People's Republic of China
| | | | | | | | | | | |
Collapse
|
45
|
Kalimuthu K, Cha BS, Kim S, Park KS. Eco-friendly synthesis and biomedical applications of gold nanoparticles: A review. Microchem J 2020. [DOI: 10.1016/j.microc.2019.104296] [Citation(s) in RCA: 70] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
|
46
|
Lu L, Yu J, Liu X, Yang X, Zhou Z, Jin Q, Xiao R, Wang C. Rapid, quantitative and ultra-sensitive detection of cancer biomarker by a SERRS-based lateral flow immunoassay using bovine serum albumin coated Au nanorods. RSC Adv 2020; 10:271-281. [PMID: 35492524 PMCID: PMC9047559 DOI: 10.1039/c9ra09471g] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2019] [Accepted: 12/14/2019] [Indexed: 12/26/2022] Open
Abstract
A rapid, sensitive, and stable SERRS-LFIA strip was developed for AFP detection using BSA-coated AuNRs as SERRS nanotags.
Collapse
Affiliation(s)
- Luchun Lu
- College of Life Sciences
- Anhui Agricultural University
- Hefei 230036
- PR China
- Beijing Institute of Radiation Medicine
| | - Jiangliu Yu
- College of Life Sciences
- Anhui Agricultural University
- Hefei 230036
- PR China
| | - Xiaoxian Liu
- College of Life Sciences
- Anhui Agricultural University
- Hefei 230036
- PR China
| | - Xingsheng Yang
- College of Life Sciences
- Anhui Agricultural University
- Hefei 230036
- PR China
| | - Zihui Zhou
- Anhui Provincial Key Laboratory of Veterinary Pathobiology and Disease Control
- Anhui Agricultural University
- Hefei 230036
- PR China
| | - Qing Jin
- College of Life Sciences
- Anhui Agricultural University
- Hefei 230036
- PR China
| | - Rui Xiao
- College of Life Sciences
- Anhui Agricultural University
- Hefei 230036
- PR China
- Beijing Institute of Radiation Medicine
| | - Chongwen Wang
- College of Life Sciences
- Anhui Agricultural University
- Hefei 230036
- PR China
- Beijing Institute of Radiation Medicine
| |
Collapse
|
47
|
Fu X, Wen J, Li J, Lin H, Liu Y, Zhuang X, Tian C, Chen L. Highly sensitive detection of prostate cancer specific PCA3 mimic DNA using SERS-based competitive lateral flow assay. NANOSCALE 2019; 11:15530-15536. [PMID: 31393497 DOI: 10.1039/c9nr04864b] [Citation(s) in RCA: 59] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
Accurate analysis of prostate cancer specific biomarkers plays an important role in the early diagnosis of prostate cancer. Traditional colorimetric lateral flow assay (LFA) has the limitations of low detection sensitivity and qualitative or semiquantitative detection. In this study, we developed a novel surface-enhanced Raman scattering (SERS)-based competitive LFA for the rapid and highly sensitive quantitative evaluation of prostate cancer antigen 3 (PCA3) mimic DNA. Herein, the competitive hybridization interaction with capture DNA between target PCA3 mimic DNA and reporter DNA-labeled SERS nanotags results in a change in the amount of SERS nanotags on the test line. The quantitative analysis of target PCA3 mimic DNA was realized by monitoring the Raman peak intensity of SERS nanotags on the test line. The limit of detection of PCA3 mimic DNA was estimated to be 3 fM, which is about three orders of magnitude more sensitive than that of a commercially available kit. By combining the outstanding characteristics of the well-established SERS-based competitive strategy and LFA platform, our design has strong potential for the early diagnosis of prostate cancer and other diseases.
Collapse
Affiliation(s)
- Xiuli Fu
- School of Chemistry and Chemical Engineering, Yantai University, Yantai 264005, China.
| | - Jiahui Wen
- School of Chemistry and Chemical Engineering, Yantai University, Yantai 264005, China.
| | - Jingwen Li
- School of Chemistry and Chemical Engineering, Yantai University, Yantai 264005, China.
| | - Hao Lin
- School of Chemistry and Chemical Engineering, Yantai University, Yantai 264005, China.
| | - Yongming Liu
- School of Chemistry and Chemical Engineering, Yantai University, Yantai 264005, China.
| | - Xuming Zhuang
- School of Chemistry and Chemical Engineering, Yantai University, Yantai 264005, China.
| | - Chunyuan Tian
- School of Chemistry and Chemical Engineering, Yantai University, Yantai 264005, China.
| | - Lingxin Chen
- CAS Key Laboratory of Coastal Environmental Processes and Ecological Remediation, The Research Center for Coastal Environmental Engineering and Technology, Yantai Institute of Coastal Zone Research, Chinese Academy of Sciences, Yantai 264003, China. and Laboratory for Marine Biology and Biotechnology, Pilot National Laboratory for Marine Science and Technology, Qingdao 266237, China and Center for Ocean Mega-Science, Chinese Academy of Sciences, Qingdao 266071, China
| |
Collapse
|
48
|
RETRACTED: A SERS-based lateral flow assay biosensor for quantitative and ultrasensitive detection of interleukin-6 in unprocessed whole blood. Biosens Bioelectron 2019; 141:111432. [DOI: 10.1016/j.bios.2019.111432] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2019] [Revised: 06/04/2019] [Accepted: 06/10/2019] [Indexed: 01/18/2023]
|
49
|
Wang Y, Hou Y, Li H, Yang M, Zhao P, Sun B. RETRACTED ARTICLE: A SERS-based lateral flow assay for the stroke biomarker S100-β. Mikrochim Acta 2019; 186:548. [DOI: 10.1007/s00604-019-3634-z] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2019] [Accepted: 06/24/2019] [Indexed: 11/29/2022]
|
50
|
Liu L, Yang D, Liu G. Signal amplification strategies for paper-based analytical devices. Biosens Bioelectron 2019; 136:60-75. [DOI: 10.1016/j.bios.2019.04.043] [Citation(s) in RCA: 96] [Impact Index Per Article: 16.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2019] [Revised: 04/15/2019] [Accepted: 04/21/2019] [Indexed: 12/26/2022]
|