1
|
Xu H, Hang Y, Wu Z, Lei X, Deng J, Yang J. Capillary-driven microchip integrated with nickel phosphide hybrid-modified electrode for the electrochemical detection of glucose. Anal Chim Acta 2024; 1316:342882. [PMID: 38969418 DOI: 10.1016/j.aca.2024.342882] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2024] [Revised: 05/06/2024] [Accepted: 06/16/2024] [Indexed: 07/07/2024]
Abstract
BACKGROUND Transition metal phosphides with properties similar to platinum metal have received increasing attention for the non-enzymatic detection of glucose. However, the requirement of highly corrosive reagent during sample pretreatment would impose a potential risk to the human body, limiting their practical applications. RESULTS In this study, we report a self-powered microfluidic device for the non-enzymatic detection of glucose using nickel phosphide (Ni2P) hybrid as the catalyst. The Ni2P hybrid is synthesized by pyrolysis of metal-organic framework (MOF)-based precursor and in-situ phosphating process, showing two linear detection ranges (1 μM-1 mM, 1 mM-6 mM) toward glucose with the detection limit of 0.32 μM. The good performance of Ni2P hybrid for glucose is attributed to the synergistic effect of Ni2P active sites and N-doped porous carbon matrix. The microchip is integrated with a NaOH-loaded paper pad and a capillary-based micropump, enabling the automatic NaOH redissolution and delivery of sample solution into the detection chamber. Under the optimized condition, the Ni2P hybrid-based microchip realized the detection of glucose in a user-friendly way. Besides, the feasibility of using this microchip for glucose detection in real serum samples has also been validated. SIGNIFICANCE This article presents a facile fabrication method utilizing a MOF template to synthesize a Ni2P hybrid catalyst. By leveraging the synergy between the Ni2P active sites and the N-doped carbon matrix, an exceptional electrochemical detection performance for glucose has been achieved. Additionally, a self-powered chip device has been developed for convenient glucose detection based on the pre-established high pH environment on the chip.
Collapse
Affiliation(s)
- Hongyang Xu
- Key Laboratory of Biorheological Science and Technology, Ministry of Education and Bioengineering College, Chongqing University, Chongqing, 400044, China
| | - Yulu Hang
- Key Laboratory of Biorheological Science and Technology, Ministry of Education and Bioengineering College, Chongqing University, Chongqing, 400044, China
| | - Zhangying Wu
- Key Laboratory of Biorheological Science and Technology, Ministry of Education and Bioengineering College, Chongqing University, Chongqing, 400044, China
| | - Xiaoyu Lei
- Key Laboratory of Biorheological Science and Technology, Ministry of Education and Bioengineering College, Chongqing University, Chongqing, 400044, China
| | - Jinan Deng
- Key Laboratory of Biorheological Science and Technology, Ministry of Education and Bioengineering College, Chongqing University, Chongqing, 400044, China.
| | - Jun Yang
- Key Laboratory of Biorheological Science and Technology, Ministry of Education and Bioengineering College, Chongqing University, Chongqing, 400044, China.
| |
Collapse
|
2
|
Wu P, Fan J, Tai Y, He X, Zheng D, Yao Y, Sun S, Ying B, Luo Y, Hu W, Sun X, Li Y. Ag@TiO 2 nanoribbon array: a high-performance sensor for electrochemical non-enzymatic glucose detection in beverage sample. Food Chem 2024; 447:139018. [PMID: 38503067 DOI: 10.1016/j.foodchem.2024.139018] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2023] [Revised: 03/02/2024] [Accepted: 03/10/2024] [Indexed: 03/21/2024]
Abstract
Developing an accurate, cost-effective, reliable, and stable glucose detection sensor for the food industry poses a significant yet challenging endeavor. Herein, we present a silver nanoparticle-decorated titanium dioxide nanoribbon array on titanium plate (Ag@TiO2/TP) as an efficient electrode for non-enzymatic glucose detection in alkaline environments. Electrochemical evaluations of the Ag@TiO2/TP electrode reveal a broad linear response range (0.001 mM - 4 mM), high sensitivity (19,106 and 4264 μA mM-1 cm-2), rapid response time (6 s), and a notably low detection limit (0.18 μM, S/N = 3). Moreover, its efficacy in measuring glucose in beverage samples shows its practical applicability. The impressive performance and structural benefits of the Ag@TiO2/TP electrode highlight its potential in advancing electrochemical sensors for small molecule detection.
Collapse
Affiliation(s)
- Peilin Wu
- Department of Laboratory Medicine, West China Hospital, Sichuan University, Chengdu 610041, Sichuan, China
| | - Jiwen Fan
- Department of Laboratory Medicine, West China Hospital, Sichuan University, Chengdu 610041, Sichuan, China
| | - Yunze Tai
- Department of Laboratory Medicine, West China Hospital, Sichuan University, Chengdu 610041, Sichuan, China
| | - Xun He
- Institute of Fundamental and Frontier Sciences, University of Electronic Science and Technology of China, Chengdu 610054, Sichuan, China
| | - Dongdong Zheng
- College of Chemistry, Chemical Engineering and Materials Science, Shandong Normal University, Jinan 250014, Shandong, China
| | - Yongchao Yao
- Department of Laboratory Medicine, West China Hospital, Sichuan University, Chengdu 610041, Sichuan, China
| | - Shengjun Sun
- College of Chemistry, Chemical Engineering and Materials Science, Shandong Normal University, Jinan 250014, Shandong, China
| | - Binwu Ying
- Department of Laboratory Medicine, West China Hospital, Sichuan University, Chengdu 610041, Sichuan, China
| | - Yao Luo
- Department of Laboratory Medicine, West China Hospital, Sichuan University, Chengdu 610041, Sichuan, China
| | - Wenchuang Hu
- Department of Laboratory Medicine, West China Hospital, Sichuan University, Chengdu 610041, Sichuan, China
| | - Xuping Sun
- Institute of Fundamental and Frontier Sciences, University of Electronic Science and Technology of China, Chengdu 610054, Sichuan, China; College of Chemistry, Chemical Engineering and Materials Science, Shandong Normal University, Jinan 250014, Shandong, China.
| | - Yi Li
- Department of Laboratory Medicine, West China Hospital, Sichuan University, Chengdu 610041, Sichuan, China.
| |
Collapse
|
3
|
Pan Y, Yu R, Jiang Y, Zhong H, Yuan Q, Lee CKW, Yang R, Chen S, Chen Y, Poon WY, Li MG. Heterogeneous Cu xO Nano-Skeletons from Waste Electronics for Enhanced Glucose Detection. NANO-MICRO LETTERS 2024; 16:249. [PMID: 39023649 PMCID: PMC11258110 DOI: 10.1007/s40820-024-01467-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/28/2024] [Accepted: 06/23/2024] [Indexed: 07/20/2024]
Abstract
Electronic waste (e-waste) and diabetes are global challenges to modern societies. However, solving these two challenges together has been challenging until now. Herein, we propose a laser-induced transfer method to fabricate portable glucose sensors by recycling copper from e-waste. We bring up a laser-induced full-automatic fabrication method for synthesizing continuous heterogeneous CuxO (h-CuxO) nano-skeletons electrode for glucose sensing, offering rapid (< 1 min), clean, air-compatible, and continuous fabrication, applicable to a wide range of Cu-containing substrates. Leveraging this approach, h-CuxO nano-skeletons, with an inner core predominantly composed of Cu2O with lower oxygen content, juxtaposed with an outer layer rich in amorphous CuxO (a-CuxO) with higher oxygen content, are derived from discarded printed circuit boards. When employed in glucose detection, the h-CuxO nano-skeletons undergo a structural evolution process, transitioning into rigid Cu2O@CuO nano-skeletons prompted by electrochemical activation. This transformation yields exceptional glucose-sensing performance (sensitivity: 9.893 mA mM-1 cm-2; detection limit: 0.34 μM), outperforming most previously reported glucose sensors. Density functional theory analysis elucidates that the heterogeneous structure facilitates gluconolactone desorption. This glucose detection device has also been downsized to optimize its scalability and portability for convenient integration into people's everyday lives.
Collapse
Affiliation(s)
- Yexin Pan
- Center on Smart Manufacturing, Division of Integrative Systems and Design, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong SAR, 999077, People's Republic of China
| | - Ruohan Yu
- Center on Smart Manufacturing, Division of Integrative Systems and Design, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong SAR, 999077, People's Republic of China
- The Sanya Science and Education Innovation Park of Wuhan University of Technology, Sanya, 572000, People's Republic of China
| | - Yalong Jiang
- State Key Laboratory of New Textile Materials and Advanced Processing Technologies, Wuhan Textile University, Wuhan, 430200, People's Republic of China
| | - Haosong Zhong
- Center on Smart Manufacturing, Division of Integrative Systems and Design, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong SAR, 999077, People's Republic of China
| | - Qiaoyaxiao Yuan
- Center on Smart Manufacturing, Division of Integrative Systems and Design, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong SAR, 999077, People's Republic of China
| | - Connie Kong Wai Lee
- Center on Smart Manufacturing, Division of Integrative Systems and Design, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong SAR, 999077, People's Republic of China
| | - Rongliang Yang
- Center on Smart Manufacturing, Division of Integrative Systems and Design, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong SAR, 999077, People's Republic of China
| | - Siyu Chen
- Center on Smart Manufacturing, Division of Integrative Systems and Design, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong SAR, 999077, People's Republic of China
| | - Yi Chen
- Center on Smart Manufacturing, Division of Integrative Systems and Design, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong SAR, 999077, People's Republic of China
| | - Wing Yan Poon
- Center on Smart Manufacturing, Division of Integrative Systems and Design, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong SAR, 999077, People's Republic of China
| | - Mitch Guijun Li
- Center on Smart Manufacturing, Division of Integrative Systems and Design, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong SAR, 999077, People's Republic of China.
| |
Collapse
|
4
|
Zhou Y, Li L, Tong J, Chen X, Deng W, Chen Z, Xiao X, Yin Y, Zhou Q, Gao Y, Hu X, Wang Y. Advanced nanomaterials for electrochemical sensors: application in wearable tear glucose sensing technology. J Mater Chem B 2024; 12:6774-6804. [PMID: 38920094 DOI: 10.1039/d4tb00790e] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/27/2024]
Abstract
In the last few decades, tear-based biosensors for continuous glucose monitoring (CGM) have provided new avenues for the diagnosis of diabetes. The tear CGMs constructed from nanomaterials have been extensively demonstrated by various research activities in this field and are gradually witnessing their most prosperous period. A timely and comprehensive review of the development of tear CGMs in a compartmentalized manner from a nanomaterials perspective would greatly broaden this area of research. However, to our knowledge, there is a lack of specialized reviews and comprehensive cohesive reports in this area. First, this paper describes the principles and development of electrochemical glucose sensors. Then, a comprehensive summary of various advanced nanomaterials recently reported for potential applications and construction strategies in tear CGMs is presented in a compartmentalized manner, focusing on sensing properties. Finally, the challenges, strategies, and perspectives used to design tear CGM materials are emphasized, providing valuable insights and guidance for the construction of tear CGMs from nanomaterials in the future.
Collapse
Affiliation(s)
- Yue Zhou
- Department of Emergency Medicine, West China Hospital, Sichuan University, West China School of Nursing, Sichuan University, Disaster Medical Center, Sichuan University & Nursing Key Laboratory of Sichuan Province, No. 37 Guoxue Alley, Chengdu, Sichuan, 610041, China.
| | - Lei Li
- National Engineering Research Center for Biomaterials & College of Biomedical Engineering, Sichuan University, Chengdu, Sichuan, 610065, China
| | - Jiale Tong
- Department of Emergency Medicine, West China Hospital, Sichuan University, West China School of Nursing, Sichuan University, Disaster Medical Center, Sichuan University & Nursing Key Laboratory of Sichuan Province, No. 37 Guoxue Alley, Chengdu, Sichuan, 610041, China.
| | - Xiaoli Chen
- Department of Emergency Medicine, West China Hospital, Sichuan University, West China School of Nursing, Sichuan University, Disaster Medical Center, Sichuan University & Nursing Key Laboratory of Sichuan Province, No. 37 Guoxue Alley, Chengdu, Sichuan, 610041, China.
| | - Wei Deng
- Department of Orthopedics Pidu District People's Hospital, The Third Affiliated Hospital of Chengdu Medical College Chengdu, Sichuan, 611730, China
| | - Zhiyu Chen
- National Engineering Research Center for Biomaterials & College of Biomedical Engineering, Sichuan University, Chengdu, Sichuan, 610065, China
| | - Xuanyu Xiao
- National Engineering Research Center for Biomaterials & College of Biomedical Engineering, Sichuan University, Chengdu, Sichuan, 610065, China
| | - Yong Yin
- Department of Orthopedics Pidu District People's Hospital, The Third Affiliated Hospital of Chengdu Medical College Chengdu, Sichuan, 611730, China
| | - Qingsong Zhou
- Department of Orthopedics Pidu District People's Hospital, The Third Affiliated Hospital of Chengdu Medical College Chengdu, Sichuan, 611730, China
| | - Yongli Gao
- Department of Emergency Medicine, West China Hospital, Sichuan University, West China School of Nursing, Sichuan University, Disaster Medical Center, Sichuan University & Nursing Key Laboratory of Sichuan Province, No. 37 Guoxue Alley, Chengdu, Sichuan, 610041, China.
| | - Xuefeng Hu
- West China School of Basic Medical Sciences & Forensic Medicine, Sichuan University, 3-16 Renmin South Road, Chengdu, Sichuan, 610041, China.
| | - Yunbing Wang
- National Engineering Research Center for Biomaterials & College of Biomedical Engineering, Sichuan University, Chengdu, Sichuan, 610065, China
| |
Collapse
|
5
|
Ferlazzo A, Celesti C, Iannazzo D, Ampelli C, Giusi D, Costantino V, Neri G. Functionalization of Carbon Nanofibers with an Aromatic Diamine: Toward a Simple Electrochemical-Based Sensing Platform for the Selective Sensing of Glucose. ACS OMEGA 2024; 9:27085-27092. [PMID: 38947806 PMCID: PMC11209887 DOI: 10.1021/acsomega.4c00525] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/16/2024] [Revised: 02/24/2024] [Accepted: 03/04/2024] [Indexed: 07/02/2024]
Abstract
Despite a variety of glucose sensors being available today, the development of nonenzymatic devices for the determination of this biologically relevant analyte is still of particular interest in several applicative sectors. Here, we report the development of an impedimetric, enzyme-free electrochemical glucose sensor based on carbon nanofibers (CNFs) functionalized with an aromatic diamine via a simple wet chemistry functionalization. The electrochemical performance of the chemically modified carbon-based screen-printed electrodes (SPCEs) was evaluated by electrical impedance spectroscopy (EIS), demonstrating a high selectivity of the sensor for glucose with respect to other sugars, such as fructose and sucrose. The sensing parameters to obtain a reliable calibration curve and the selective glucose sensing mechanism are discussed here, highlighting the performance of this novel electrochemical sensor for the selective sensing of this important analyte. Two linear trends were noted, one at low concentrations (0-1200 μM) and the other from 1200 to 5000 μM. The limit of detection (LOD), calculated as the (standard error/slope)*3.3, was 18.64 μM. The results of this study highlight the performance of the developed novel electrochemical sensor for the selective sensing of glucose.
Collapse
Affiliation(s)
- Angelo Ferlazzo
- Department
of Chemical Sciences, University of Catania, Viale Andrea Doria, 6, I-95125 Catania, Italy
| | - Consuelo Celesti
- Department
of Engineering, University of Messina, Contrada Di Dio, I-98166 Messina, Italy
| | - Daniela Iannazzo
- Department
of Engineering, University of Messina, Contrada Di Dio, I-98166 Messina, Italy
| | - Claudio Ampelli
- Department
of Chemical, Biological, Pharmaceutical and Environmental Sciences
(ChiBioFarAm), University of Messina and
INSTM, Via F. Stagno
d’Alcontres 31, I-98166 Messina, Italy
| | - Daniele Giusi
- Department
of Chemical, Biological, Pharmaceutical and Environmental Sciences
(ChiBioFarAm), University of Messina and
INSTM, Via F. Stagno
d’Alcontres 31, I-98166 Messina, Italy
| | - Veronica Costantino
- Department
of Chemical, Biological, Pharmaceutical and Environmental Sciences
(ChiBioFarAm), University of Messina and
INSTM, Via F. Stagno
d’Alcontres 31, I-98166 Messina, Italy
| | - Giovanni Neri
- Department
of Engineering, University of Messina, Contrada Di Dio, I-98166 Messina, Italy
| |
Collapse
|
6
|
Zhu R, Song Y, Hu J, Zhu K, Liu L, Jiang Y, Xie L, Pang H. Conductive Metal-Organic Framework Grown on the Nickel-Based Hydroxide to Realize High-Performance Electrochemical Glucose Sensing. Chemistry 2024; 30:e202400982. [PMID: 38533890 DOI: 10.1002/chem.202400982] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2024] [Revised: 03/27/2024] [Accepted: 03/27/2024] [Indexed: 03/28/2024]
Abstract
Glucose holds significant importance in disease diagnosis as well as beverage quality monitoring. The high-efficiency electrochemical sensor plays a crucial role in the electrochemical conversion technology. Ni(OH)2 nanosheets are provided with high specific surface area and redox activity that are widely used in electrochemistry. Conductive metal-organic frameworks (cMOFs) perfectly combine the structural controllability of organic materials with the long-range ordering of inorganic materials that possess the characteristic of high electron mobility. Based on the above considerations, the combination of Ni(OH)2 and Ni-HHTP (HHTP=2,3,6,7,10,11-hexahydroxytriphenylene) as an electrode modification material is designed to enhance electrochemical performance. In this work, to improve glucose detection, a sequence of Ni(OH)2@NiCo-HHTP and NiM-LDH@Ni-HHTP (M=Co2+, Mn2+, Cu2+, LDH=layered double hydroxide) are successfully synthesised by doping metals into Ni-HHTP and Ni(OH)2, respectively. As a result, NiCu-LDH@Ni-HHTP showed the best excellent glucose detection sensitivity.
Collapse
Affiliation(s)
- Rongmei Zhu
- School of Chemistry and Chemical Engineering, Institute for Innovative Materials and Energy, Yangzhou University, Yangzhou, Jiangsu 225009, P. R. China
| | - Yongzhen Song
- School of Chemistry and Chemical Engineering, Institute for Innovative Materials and Energy, Yangzhou University, Yangzhou, Jiangsu 225009, P. R. China
| | - Jinliang Hu
- Jiangsu Yangnong Chemical Group Co. Ltd., Yangzhou, 225009, P. R. China
| | - Keda Zhu
- School of Chemistry and Chemical Engineering, Institute for Innovative Materials and Energy, Yangzhou University, Yangzhou, Jiangsu 225009, P. R. China
| | - Limei Liu
- School of Chemistry and Chemical Engineering, Institute for Innovative Materials and Energy, Yangzhou University, Yangzhou, Jiangsu 225009, P. R. China
| | - Yuxuan Jiang
- School of Chemistry and Chemical Engineering, Institute for Innovative Materials and Energy, Yangzhou University, Yangzhou, Jiangsu 225009, P. R. China
| | - Liru Xie
- School of Chemistry and Chemical Engineering, Institute for Innovative Materials and Energy, Yangzhou University, Yangzhou, Jiangsu 225009, P. R. China
| | - Huan Pang
- School of Chemistry and Chemical Engineering, Institute for Innovative Materials and Energy, Yangzhou University, Yangzhou, Jiangsu 225009, P. R. China
| |
Collapse
|
7
|
Ko Y, Oh Y, Park CH, Kim SH. Designing Tough Hydrogel Shells for Glucose Sensing. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2024; 20:e2310283. [PMID: 38227378 DOI: 10.1002/smll.202310283] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/10/2023] [Revised: 12/26/2023] [Indexed: 01/17/2024]
Abstract
Conventional hydrogel microcapsules often suffer from inadequate mechanical stability, hindering their use. Here, water-cored double-network (DN) hydrogel shells are designed, formed by polyacrylamide and calcium alginate networks using triple-emulsion templates. These DN hydrogel shells offer robust mechanical stability, optical transparency, and a precisely-defined cut-off threshold. The feasibility of this platform is demonstrated through the development of a fluorometric glucose sensor. Glucose oxidase is enclosed within the water core, while a pH-responsive fluorescent dye is incorporated into the DN shells. Glucose diffuses into the core through the DN shells, where the glucose oxidase converts glucose into gluconic acid, leading to pH reduction and a subsequent decrease in fluorescence intensity of DN shells. Additionally, the pH-sensitive colorant dissolved in the medium enables visual pH assessment. Thus, glucose levels can be determined using both fluorometric and colorimetric methods. Notably, the DN shells exhibit exceptional stability, enduring intense mechanical stress and cycles of drying and rehydration without leakage. Moreover, the DN shells act as effective barriers, safeguarding glucose oxidase against proteolysis by large disruptive proteins, like pancreatin. This versatile DN shell platform extends beyond glucose oxidase encapsulation, serving as a foundation for various capsule sensors utilizing enzymes and heterogeneous catalysts.
Collapse
Affiliation(s)
- Yeounju Ko
- Department of Chemical and Biomolecular Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon, 34141, Republic of Korea
| | - Yoonjin Oh
- Department of Chemical and Biomolecular Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon, 34141, Republic of Korea
| | - Chan Ho Park
- Department of Chemical and Biomolecular Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon, 34141, Republic of Korea
- Department of Chemical and Biological Engineering, Gachon University, Seongnam, 13120, Republic of Korea
| | - Shin-Hyun Kim
- Department of Chemical and Biomolecular Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon, 34141, Republic of Korea
| |
Collapse
|
8
|
He L, Su J, You T, Xiao S, Huang P, He D, Jiang P. Rapid and facile preparation of NiFe-layered double hydroxide nanosheets as self-supported electrode for glucose detection in drink sample. Food Chem 2024; 439:138163. [PMID: 38091783 DOI: 10.1016/j.foodchem.2023.138163] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2023] [Revised: 12/01/2023] [Accepted: 12/05/2023] [Indexed: 01/10/2024]
Abstract
Layered double hydroxides have been widely used for electrochemical glucose detection due to their layered structure with more active sites, but they suffer from lower electrical conductivity and long-time hydrothermal preparation. In this paper, NiFe-layered double hydroxide nanosheets supported on nickel foam (NiFe-LDH NSs/NF) was prepared using an ultrafast and facile method via in-situ corroding foam nickel in FeCl3 solution under room temperature, and the whole synthetic process can be accomplished within several minutes. The as-fabricated NiFe-LDH NSs/NF shows significant catalytic activity in the glucose oxidation, showing its great promise in glucose detection. As a self-supported electrode, NiFe-LDH NSs/NF is favorable for glucose detection, with a sensitivity of 9.79 and 3.29 mA mM-1 cm-2 within the linear range of 0.001 to 1.16 mM and 1.16 to 4.67 mM, respectively. Moreover, NiFe-LDH NSs/NF is also selective and reliable towards glucose detection in drink sample.
Collapse
Affiliation(s)
- Liu He
- Chongqing Key Laboratory of Inorganic Functional Materials, College of Chemistry, Chongqing Normal University, Chongqing 401331, China
| | - Jiangyu Su
- Chongqing Key Laboratory of Inorganic Functional Materials, College of Chemistry, Chongqing Normal University, Chongqing 401331, China
| | - Teng You
- Chongqing Key Laboratory of Inorganic Functional Materials, College of Chemistry, Chongqing Normal University, Chongqing 401331, China
| | - Shuang Xiao
- Chongqing Key Laboratory of Inorganic Functional Materials, College of Chemistry, Chongqing Normal University, Chongqing 401331, China
| | - Ping Huang
- Chongqing Key Laboratory of Inorganic Functional Materials, College of Chemistry, Chongqing Normal University, Chongqing 401331, China
| | - Daiping He
- Chongqing Key Laboratory of Inorganic Functional Materials, College of Chemistry, Chongqing Normal University, Chongqing 401331, China
| | - Ping Jiang
- Chongqing Key Laboratory of Inorganic Functional Materials, College of Chemistry, Chongqing Normal University, Chongqing 401331, China.
| |
Collapse
|
9
|
Abraham MK, Madanan AS, Varghese S, R S L, Shkhair AI, N S V, George S. Fluorescent Enzymatic Sensor Based Glucose Oxidase Modified Bovine Serum Albumin-Gold Nanoclusters for Detection of Glucose. Chempluschem 2024; 89:e202300601. [PMID: 38241333 DOI: 10.1002/cplu.202300601] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2023] [Revised: 01/13/2024] [Accepted: 01/18/2024] [Indexed: 01/21/2024]
Abstract
An enzymatic fluorescent probe is developed for the selective detection of glucose. In this work, a Bovine Serum Albumin stabilized gold nanocluster (BSA-AuNCs) was synthesized by microwave assisted method, and it is modified with glucose oxidase, thereby a fluorescent enzymatic sensor (BSA-AuNCs@GoX) was designed for the sensitive detection of glucose with a limit of detection of 0.03 mM. The red fluorescence exhibited by the probe is quenched by the production of H2O2 on addition of glucose via. a static quenching mechanism from UV visible absorption and Fluorescence lifetime results. The developed probe exhibits good selectivity and sensitivity with other coexisting molecular species such as glycine, creatinine, methionine, histidine, uric acid, albumin, and ions such as sodium, potassium, calcium, magnesium, zinc etc. that appear in the body fluid. The practical applicability was studied in paper strip and extended its reproducibility in biological matrixes such as human serum and urine and found a good recovery percentage of 94-101 %. By this way, we have fabricated an effective fluorescent enzymatic "turn-off" sensing probe for the detection of glucose.
Collapse
Affiliation(s)
- Merin K Abraham
- Department of Chemistry, School of Physical and Mathematical Sciences, Research Centre, University of Kerala, Kariavattom Campus, Thiruvananthapura, 695581, Kerala, India Phone
| | - Anju S Madanan
- Department of Chemistry, School of Physical and Mathematical Sciences, Research Centre, University of Kerala, Kariavattom Campus, Thiruvananthapura, 695581, Kerala, India Phone
| | - Susan Varghese
- Department of Chemistry, School of Physical and Mathematical Sciences, Research Centre, University of Kerala, Kariavattom Campus, Thiruvananthapura, 695581, Kerala, India Phone
| | - Lekshmi R S
- Department of Chemistry, School of Physical and Mathematical Sciences, Research Centre, University of Kerala, Kariavattom Campus, Thiruvananthapura, 695581, Kerala, India Phone
| | - Ali Ibrahim Shkhair
- Department of Chemistry, School of Physical and Mathematical Sciences, Research Centre, University of Kerala, Kariavattom Campus, Thiruvananthapura, 695581, Kerala, India Phone
| | - Vijila N S
- Department of Chemistry, School of Physical and Mathematical Sciences, Research Centre, University of Kerala, Kariavattom Campus, Thiruvananthapura, 695581, Kerala, India Phone
| | - Sony George
- Department of Chemistry, School of Physical and Mathematical Sciences, Research Centre, University of Kerala, Kariavattom Campus, Thiruvananthapura, 695581, Kerala, India Phone
| |
Collapse
|
10
|
Shabanur Matada MS, Kuppuswamy GP, Sasi S, Velappa Jayaraman S, Nutalapati V, Senthil Kumar S, Sivalingam Y. Pyrene Derivative Incorporated Ni MOF as an Enzyme Mimic for Noninvasive Salivary Glucose Detection Toward Diagnosis of Diabetes Mellitus. ACS APPLIED MATERIALS & INTERFACES 2024; 16:17219-17231. [PMID: 38561895 DOI: 10.1021/acsami.3c19431] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/04/2024]
Abstract
Herein, we demonstrate the detection of glucose in a noninvasive and nonenzymatic manner by utilizing an extended gate field-effect transistor (EGFET) based on the organic molecule pyrene phosphonic acid (PyP4OH8) incorporated nickel metal-organic framework (NiOM-MOF). The prepared electrode responds selectively to glucose instead of sucrose, fructose, maltose, ascorbic acid, and uric acid in a 1× phosphate buffer saline solution. Also, utilizing the scanning Kelvin probe system, the sensing electrode's work function (Φ) is measured to validate the glucose-sensing mechanism. The sensitivity, detection range, response time, limit of detection, and limit of quantification of the electrode are determined to be 24.5 μA mM-1 cm-2, 20 μM to 10 mM, less than 5 s, 2.73 μM, and 8.27 μM, respectively. Most interestingly, the developed electrode follows the Michaelis-Menten kinetics, and the calculated rate constant (km) 0.07 mM indicates a higher affinity of NiOM-MOF toward glucose. The real-time analysis has revealed that the prepared electrode is sensitive to detect glucose in real human saliva, and it can be an alternative device for the noninvasive detection of glucose. Overall, the outcomes of the EGFET studies demonstrate that the prepared electrodes are well-suited for expeditious detection of glucose levels in saliva.
Collapse
Affiliation(s)
- Mallikarjuna Swamy Shabanur Matada
- Laboratory of Sensors, Energy and Electronic Devices (Lab SEED), Department of Physics and Nanotechnology, SRMIST, Kattankulathur, Tamil Nadu 603203, India
| | - Guru Prasad Kuppuswamy
- Laboratory of Sensors, Energy and Electronic Devices (Lab SEED), Department of Physics and Nanotechnology, SRMIST, Kattankulathur, Tamil Nadu 603203, India
| | - Sheethal Sasi
- Laboratory of Sensors, Energy and Electronic Devices (Lab SEED), Department of Physics and Nanotechnology, SRMIST, Kattankulathur, Tamil Nadu 603203, India
| | - Surya Velappa Jayaraman
- Novel, Advanced, and Applied Materials (NAAM) Laboratory, Department of Physics and Nanotechnology, SRMIST, Kattankulathur, Tamil Nadu 603203, India
- New Industry Creation Hatchery Center (NICHe), Tohoku University, Aoba-ku, Sendai Miyagi 980-8579, Japan
| | - Venkatramaiah Nutalapati
- Functional Materials Laboratory, Department of Chemistry, Faculty of Engineering and Technology, SRM Institute of Science and Technology, Kattankulathur, Tamil Nadu 603203, India
| | - Shanmugam Senthil Kumar
- Electrodics and Electrocatalysis Division, CSIR-Central Electrochemical Research Institute (CSIR-CECRI) Campus, Karaikudi, Tamil Nadu 630006, India
| | - Yuvaraj Sivalingam
- Laboratory of Sensors, Energy and Electronic Devices (Lab SEED), Department of Physics and Nanotechnology, SRMIST, Kattankulathur, Tamil Nadu 603203, India
- Sensors Lab, Computer, Electrical, and Mathematical Sciences and Engineering Division (CEMSE), King Abdullah University of Science and Technology (KAUST), Thuwal 23955-6900, Kingdom of Saudi Arabia
| |
Collapse
|
11
|
Lee T, Park J, Oh SH, Cheong DY, Roh S, You JH, Hong Y, Lee G. Glucose Oxidase Activity Colorimetric Assay Using Redox-Sensitive Electrochromic Nanoparticle-Functionalized Paper Sensors. ACS OMEGA 2024; 9:15493-15501. [PMID: 38585131 PMCID: PMC10993408 DOI: 10.1021/acsomega.4c00335] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/10/2024] [Revised: 02/23/2024] [Accepted: 03/07/2024] [Indexed: 04/09/2024]
Abstract
Glucose oxidase (GOx) activity assays are vital for various applications, including glucose metabolism estimation and fungal testing. However, conventional methods involve time-consuming and complex procedures. In this study, we present a colorimetric platform for in situ GOx activity measurement utilizing redox-sensitive electrochromic nanoparticles based on polyaniline (PAni). The glucose-adsorbed colorimetric paper sensor, herein termed Glu@CPS, is created by immobilizing ferrocene and glucose onto paper substrates that have been functionalized with PAni nanoparticles. Glu@CPS not only demonstrated rapid detection (within 5 min) but also exhibited remarkable selectivity for GOx and a limit of detection as low as 1.25 μM. Moreover, Glu@CPS demonstrated consistent accuracy in the measurement of GOx activity, exhibiting no deviations even after being stored at ambient temperature for a duration of one month. To further corroborate the effectiveness of this method, we applied Glu@CPS in the detection of GOx activity in a moldy red wine. The results highlight the promising potential of Glu@CPS as a convenient and precise platform for GOx activity measurement in diverse applications including food quality control, environmental monitoring, and early detection of fungal contamination.
Collapse
Affiliation(s)
- Taeha Lee
- Department
of Biotechnology and Bioinformatics, Korea
University, Sejong 30019, South Korea
- Interdisciplinary
Graduate Program for Artificial Intelligence Smart Convergence Technology, Korea University, Sejong 30019, South Korea
| | - Jeongmin Park
- Department
of Biotechnology and Bioinformatics, Korea
University, Sejong 30019, South Korea
| | - Seung Hyeon Oh
- Department
of Biotechnology and Bioinformatics, Korea
University, Sejong 30019, South Korea
- Interdisciplinary
Graduate Program for Artificial Intelligence Smart Convergence Technology, Korea University, Sejong 30019, South Korea
| | - Da Yeon Cheong
- Department
of Biotechnology and Bioinformatics, Korea
University, Sejong 30019, South Korea
- Interdisciplinary
Graduate Program for Artificial Intelligence Smart Convergence Technology, Korea University, Sejong 30019, South Korea
| | - Seokbeom Roh
- Department
of Biotechnology and Bioinformatics, Korea
University, Sejong 30019, South Korea
- Interdisciplinary
Graduate Program for Artificial Intelligence Smart Convergence Technology, Korea University, Sejong 30019, South Korea
| | - Jae Hyun You
- Division
of Convergence Business, Korea University, Sejong 30019, South Korea
| | - Yoochan Hong
- Department
of Medical Device, Korea Institute of Machinery
and Materials (KIMM), Daegu 42994, South Korea
| | - Gyudo Lee
- Department
of Biotechnology and Bioinformatics, Korea
University, Sejong 30019, South Korea
- Interdisciplinary
Graduate Program for Artificial Intelligence Smart Convergence Technology, Korea University, Sejong 30019, South Korea
| |
Collapse
|
12
|
Yu L, Ma X, Cao X, Zhao J. Nanostructured Polyoxometalate-Based Heterogeneous Electrode Materials for Electrochemical Sensing of Glucose. Inorg Chem 2024; 63:5952-5960. [PMID: 38497726 DOI: 10.1021/acs.inorgchem.3c04596] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/19/2024]
Abstract
We exploited a tactic to obtain a low-cost, high-efficiency, pollution-free, and stable nonenzymatic polyoxometalate-based heterogeneous electrode material for electrochemical sensing of glucose. It is first followed by the countercation exchange of K2Na8[Cu4(H2O)2(PW9O34)2] (CuPOM) using cesium chloride to prepare an insoluble CuPOM (Cs-CuPOM), which exhibits a uniform and perfect claviform shape with smooth surface. Further, it was mixed with graphite powder to prepare Cs-CuPOM-modified carbon paste electrode (Cs-CuPOM/CPE) with the Cs-CuPOM content between 15% and 50% in weight. This obtained electrode material Cs-CuPOM shows a better electrochemical sensor activity than Cs-MnPOM, Cs-FePOM, and other reported POM-based electrode materials for glucose oxidation on account of their quicker electron transfer kinetics, which also exhibits conspicuous characteristics with a wide linear range of 5-1500 μM. It also possesses a high sensitivity of 16.3 A M-1 cm-2 and a low limit of detection (LOD) of 0.99 × 10-6 M at the signal-to-noise ratio of 3. The conspicuous sensing feature, low cost, and liable synthetic method can make Cs-CuPOM a promising candidate for the exploitation of a preeminent glucose sensor.
Collapse
Affiliation(s)
- Li Yu
- College of Chemistry and Chemical Engineering, Xinyang Normal University, Xinyang, Henan 464000, China
| | - Xiaocai Ma
- College of Chemistry and Chemical Engineering, Xinyang Normal University, Xinyang, Henan 464000, China
| | - Xinhua Cao
- College of Chemistry and Chemical Engineering, Xinyang Normal University, Xinyang, Henan 464000, China
- Hebei Provincial Key Laboratory of Photoelectric Control on Surface and Interface, Hebei University of Science and Technology, Yuhua Road 70, Shijiazhuang 050080, China
| | - Junwei Zhao
- Henan Key Laboratory of Polyoxometalate Chemistry, College of Chemistry and Molecular Sciences, Henan University, Kaifeng, Henan 475004, China
| |
Collapse
|
13
|
Boucheta H, Zouaoui E, Ferkous H, Madaci A, Yadav KK, Benguerba Y. Advancing Diabetes Management: The Future of Enzyme-Less Nanoparticle-Based Glucose Sensors-A Review. J Diabetes Sci Technol 2024:19322968241236211. [PMID: 38506487 DOI: 10.1177/19322968241236211] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 03/21/2024]
Abstract
BACKGROUND Glucose is vital for biological processes, requiring blood sugar levels to be maintained between 3.88 and 6.1 mmol/L, especially during fasting. Elevated levels signal diabetes, a global concern affecting 537 million people, necessitating effective glucose-monitoring devices. METHOD Enzyme-based sensors, though selective, are sensitive to environmental factors. Nonenzymatic sensors, especially those with nanoparticles, offer stability, high surface area, and cost-effectiveness. Existing literature supports their immediate glucose oxidation, showcasing exceptional sensitivity. RESULTS This review details nonenzymatic sensors, highlighting materials, detection limits, and the promise of nanoparticle-based designs, which exhibit enhanced sensitivity and selectivity in glucose detection. CONCLUSION Nanoparticle-based sensors, as reviewed, show potential for glucose monitoring, overcoming enzyme-based limitations. The conclusion suggests future directions for advancing these sensors, emphasizing ongoing innovation in this critical research area.
Collapse
Affiliation(s)
- Hana Boucheta
- Laboratory of Physico-Chemistry Research on Surfaces and Interfaces, University of 20 August 1955, Skikda, Algeria
- Department of Process Engineering, Faculty of Technology, University of 20 August 1955, Skikda, Algeria
- Laboratory of Catalysis, Bio-Process and Environment, Department of Process Engineering, University of 20 August 1955, Skikda, Algeria
| | - Emna Zouaoui
- Department of Process Engineering, Faculty of Technology, University of 20 August 1955, Skikda, Algeria
- Laboratory of Catalysis, Bio-Process and Environment, Department of Process Engineering, University of 20 August 1955, Skikda, Algeria
| | - Hana Ferkous
- Laboratory of Mechanical Engineering and Materials, Faculty of Technology, University of 20 August 1955, Skikda, Algeria
| | - Anis Madaci
- Institute of Analytical Sciences, University of Lyon, Villeurbanne, France
- Laboratory of Materials and Electronics Systems, University El-Bachir El-Ibrahimi Bordj Bou Arreridj, Bordj Bou Arreridj, Algeria
| | - Krishna Kumar Yadav
- Faculty of Science and Technology, Madhyanchal Professional University, Bhopal, India
- Environmental and Atmospheric Sciences Research Group, Scientific Research Center, Al-Ayen University, Nasiriyah, Iraq
| | - Yacine Benguerba
- Laboratoire de Biopharmacie et Pharmacotechnie, Université Ferhat Abbas Sétif-1, Sétif, Algeria
| |
Collapse
|
14
|
Chen H, Zhou S, Chen J, Zhou J, Fan K, Pan Y, Ping J. An integrated plant glucose monitoring system based on microneedle-enabled electrochemical sensor. Biosens Bioelectron 2024; 248:115964. [PMID: 38160635 DOI: 10.1016/j.bios.2023.115964] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2023] [Revised: 12/10/2023] [Accepted: 12/20/2023] [Indexed: 01/03/2024]
Abstract
Real-time monitoring of glucose concentration changes in plants and access to plant physiological information timely are of great significance to the development of precision agriculture. Here, we innovatively present an electrochemical sensing device that combines microneedle sensors and 3D printing technology to achieve real-time monitoring of glucose in plants in a minimally invasive manner. The device consists of two components: the inner part features a highly efficient sensing interface based on platinum wire (MPt-Au-Nafion-GOx-Pu), while the outer part consists of polymer microneedles formed by 3D printing. Additionally, the polymer hollow microneedle features a slender tip diameter of only 300 μm, minimizing plant damage during the detection procedure. The device shows good detection performance, with a limit of detection (LOD) of 33.3 μM and a detection sensitivity of 17 nA/μM·cm2. It can detect glucose concentrations in the range of 100 μM to 100 mM, providing a unique solution for timely agronomic management of crops tool. By performing 12 h real-time monitoring and salt stress treat on tomato and aloe vera, the results verified the feasibility of integrated device applied to real-time glucose detection in plants.
Collapse
Affiliation(s)
- Han Chen
- Laboratory of Agricultural Information Intelligent Sensing, School of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou, 310058, PR China; Hangzhou Academy of Agricultural Sciences, Hangzhou, 310024, PR China
| | - Shenghan Zhou
- Laboratory of Agricultural Information Intelligent Sensing, School of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou, 310058, PR China; Innovation Platform of Micro/Nano Technology for Biosensing, ZJU-Hangzhou Global Scientific and Technological Innovation Center, Zhejiang University, Hangzhou, 311200, PR China
| | - Junbiao Chen
- College of Information Engineering, Hangzhou Dianzi University, Hangzhou, 310018, PR China
| | - Jin Zhou
- Laboratory of Agricultural Information Intelligent Sensing, School of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou, 310058, PR China
| | - Kai Fan
- School of Automation, Hangzhou Dianzi University, Hangzhou, 310018, PR China
| | - Yuxiang Pan
- Laboratory of Agricultural Information Intelligent Sensing, School of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou, 310058, PR China; Innovation Platform of Micro/Nano Technology for Biosensing, ZJU-Hangzhou Global Scientific and Technological Innovation Center, Zhejiang University, Hangzhou, 311200, PR China
| | - Jianfeng Ping
- Laboratory of Agricultural Information Intelligent Sensing, School of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou, 310058, PR China; Innovation Platform of Micro/Nano Technology for Biosensing, ZJU-Hangzhou Global Scientific and Technological Innovation Center, Zhejiang University, Hangzhou, 311200, PR China.
| |
Collapse
|
15
|
Pushparaj K, Catini A, Capuano R, Allegra V, Magna G, Antonelli G, Martinelli E, Agresti A, Pescetelli S, Sivalingam Y, Paolesse R, Di Natale C. Nonenzymatic Potentiometric Detection of Ascorbic Acid with Porphyrin/ZnO-Functionalized Laser-Induced Graphene as an Electrode of EGFET Sensors. ACS OMEGA 2024; 9:10650-10659. [PMID: 38463246 PMCID: PMC10918774 DOI: 10.1021/acsomega.3c09141] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/16/2023] [Revised: 01/30/2024] [Accepted: 02/01/2024] [Indexed: 03/12/2024]
Abstract
Laser-induced graphene (LIG) has emerged as a highly versatile material with significant potential in the development of electrochemical sensors. In this paper, we investigate the use of LIG and LIG functionalized with ZnO and porphyrins-ZnO as the gate electrodes of the extended gate field effect transistors (EGFETs). The resultant sensors exhibit remarkable sensitivity and selectivity, particularly toward ascorbic acid. The intrinsic sensitivity of LIG undergoes a notable enhancement through the incorporation of hybrid organic-inorganic materials. Among the variations tested, the LIG electrode coated with zinc tetraphenylporphyrin-capped ZnO nanoparticles demonstrates superior performance, reaching a limit of detection of approximately 3 nM. Furthermore, the signal ratio for 5 μM ascorbic acid relative to the same concentration of dopamine exceeds 250. The practical applicability of these sensors is demonstrated through the detection of ascorbic acid in real-world samples, specifically in a commercially available food supplement containing l-arginine. Notably, formulations with added vitamin C exhibit signals at least 25 times larger than those without, underscoring the sensors' capability to discern and quantify the presence of ascorbic acid in complex matrices. This research not only highlights the enhanced performance of LIG-based sensors through functionalization but also underscores their potential for practical applications in the analysis of vitamin-rich supplements.
Collapse
Affiliation(s)
- Kishore Pushparaj
- Department
of Electronic Engineering, University of
Rome Tor Vergata, 00133 Rome, Italy
| | - Alexandro Catini
- Department
of Electronic Engineering, University of
Rome Tor Vergata, 00133 Rome, Italy
| | - Rosamaria Capuano
- Department
of Electronic Engineering, University of
Rome Tor Vergata, 00133 Rome, Italy
| | - Valerio Allegra
- Department
of Electronic Engineering, University of
Rome Tor Vergata, 00133 Rome, Italy
| | - Gabriele Magna
- Department
of Chemical Science and Technologies, University
of Rome Tor Vergata, 00133 Rome, Italy
| | - Gianni Antonelli
- Department
of Electronic Engineering, University of
Rome Tor Vergata, 00133 Rome, Italy
| | - Eugenio Martinelli
- Department
of Electronic Engineering, University of
Rome Tor Vergata, 00133 Rome, Italy
| | - Antonio Agresti
- Department
of Electronic Engineering, University of
Rome Tor Vergata, 00133 Rome, Italy
| | - Sara Pescetelli
- Department
of Electronic Engineering, University of
Rome Tor Vergata, 00133 Rome, Italy
| | - Yuvaraj Sivalingam
- Department
of Physics and Nanotechnology, SRM Institute
of Science and Technology, Kattankulathur 603203, Tamil Nadu, India
| | - Roberto Paolesse
- Department
of Chemical Science and Technologies, University
of Rome Tor Vergata, 00133 Rome, Italy
| | - Corrado Di Natale
- Department
of Electronic Engineering, University of
Rome Tor Vergata, 00133 Rome, Italy
| |
Collapse
|
16
|
Yao W, He H, Wang F. CTAB-Modulated Electroplating of Copper Micropillar Arrays for Non-Enzymatic Glucose Sensing with Improved Sensitivity. SENSORS (BASEL, SWITZERLAND) 2024; 24:1603. [PMID: 38475139 DOI: 10.3390/s24051603] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/23/2023] [Revised: 01/05/2024] [Accepted: 01/07/2024] [Indexed: 03/14/2024]
Abstract
Micropillar array electrodes represent a promising avenue for enhancing detection sensitivity and response current. However, existing methods for depositing electrode materials on micropillar arrays often result in uneven distribution, with the thin sidewall layer being less conductive and prone to corrosion. In addressing this issue, this study introduces electroplating to enhance the copper layer on the sidewall of micropillar array electrodes. These electrodes, fabricated through standard microelectronics processes and electroplating, are proposed for non-enzymatic glucose detection, with the copper layer deposited via electroplating significantly enhancing sensitivity. Initially, the impact of cetyltrimethylammonium bromide (CTAB) concentration as an inhibitor on the surface morphology and sensitivity of the plated layer was investigated. It was discovered that CTAB could decrease surface roughness, hinder the development of large and coarse grains, generate small particles, and boost sensitivity. Compared to the uncoated electrode and plating without CTAB, sensitivity was elevated by a factor of 1.66 and 1.62, respectively. Subsequently, the alterations in plating morphology and detection performance within a range of 0.3 ASD to 3 ASD were examined. Sensitivity demonstrated a tendency to increase initially and then decrease. The electrode plated at 0.75 ASD achieved a maximum sensitivity of 3314 μA·mM-1·cm-2 and a detection limit of 15.9 μM. Furthermore, a potential mechanism explaining the impact of different morphology on detection performance due to CTAB and current density was discussed. It was believed that the presented effective strategy to enhance the sensitivity of micropillar array electrodes for glucose detection would promote the related biomedical detection applications.
Collapse
Affiliation(s)
- Wenhao Yao
- State Key Laboratory of Precision Manufacturing for Extreme Service Performance, College of Mechanical and Electrical Engineering, Central South University, Changsha 410083, China
| | - Hu He
- State Key Laboratory of Precision Manufacturing for Extreme Service Performance, College of Mechanical and Electrical Engineering, Central South University, Changsha 410083, China
| | - Fuliang Wang
- State Key Laboratory of Precision Manufacturing for Extreme Service Performance, College of Mechanical and Electrical Engineering, Central South University, Changsha 410083, China
| |
Collapse
|
17
|
Thakur AK, Sengodu P, Jadhav AH, Malmali M. Manganese Carbonate/Laser-Induced Graphene Composite for Glucose Sensing. ACS OMEGA 2024; 9:7869-7880. [PMID: 38405531 PMCID: PMC10882677 DOI: 10.1021/acsomega.3c07642] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/02/2023] [Revised: 12/22/2023] [Accepted: 01/04/2024] [Indexed: 02/27/2024]
Abstract
Laser-induced graphene (LIG) has received great interest as a potential candidate for electronic and sensing applications. In the present study, we report the enhanced performance of a manganese carbonate-decorated LIG (MnCO3/LIG) composite electrode material employed for electrochemical glucose detection. Initially, the porous LIG was fabricated by directly lasing poly(ether sulfone) membrane substrate. Then, the MnCO3/LIG composite was synthesized via a hydrothermal method. Later, MnCO3/LIG was immobilized onto a glassy carbon electrode surface and employed for glucose detection. The structure of the MnCO3/LIG composite was carefully characterized. The influence of the MnCO3/LIG composite on the performance of the electrode was investigated using cyclic voltammetry curves. The MnCO3/LIG composite exhibited an excellent sensitivity of 2731.2 μA mM-1 cm-2, and a limit of detection of 2.2 μM was obtained for the detection of glucose. Overall, the performance of the MnCO3/LIG composite was found to be superior to that of most of the MnCO3-based composites.
Collapse
Affiliation(s)
- Amit K. Thakur
- Department
of Chemical Engineering, Texas Tech University, Lubbock, Texas 79409, United States
| | - Prakash Sengodu
- Department
of Industrial Chemistry, School of Chemical Sciences, Alagappa University, Karaikudi, Tamil Nadu 630003, India
| | - Arvind H. Jadhav
- Centre
for Nano and Material Science (CNMS), Jain
University, Bangalore 562112, India
| | - Mahdi Malmali
- Department
of Chemical Engineering, Texas Tech University, Lubbock, Texas 79409, United States
| |
Collapse
|
18
|
Xia P, Pan J, Zhang Y, Mao M, Ma L, Chen J, Zhang L, Wang H, Fan H, Gao X, Deng L. Highly sensitive detection of glucose at a novel non-enzyme electrochemical sensing based on Mo-doped CoO Nanosheets. Chem Asian J 2024; 19:e202300951. [PMID: 38105351 DOI: 10.1002/asia.202300951] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2023] [Revised: 12/08/2023] [Accepted: 12/15/2023] [Indexed: 12/19/2023]
Abstract
In this work, a Mo doped CoO nanosheet grown on nickel foam (labeled as: Mo-CoO) with defect-rich and improved electron transfer capacity was designed to be used as a novel non-enzyme electrode material. Physical characterizations demonstrated the Mo elements were doped inside of the samples and they were mutually stabilized with each other, resulting in a high structural stability electrochemical catalytical activity even if the content of Mo was low. For non-enzymatic glucose electrochemical sensing, the prepared Mo-CoO-1 showed a remarkable sensitivity of 89.3 mA cm-2 mM-1 , and a low detection limit of 0.43 μM. Density functional theory (DFT) studies revealed that the doped Mo atom exhibited a higher d-band center compared to the Co atom. A stronger p-d orbital hybridization between the glucose and the Mo atoms indicated the enhancement of glucose adsorption and activation. Importantly, Mo-CoO-1 provided a good selectivity and long-term stability, which can be expected to be used in future practical applications.
Collapse
Affiliation(s)
- Pengkun Xia
- Hunan Provincial Key Laboratory of Advanced Materials for New Energy Storage and Conversion, School of Materials Science and Engineering, Hunan University of Science and Technology, Xiangtan, 411201, People's Republic of China
| | - Jing Pan
- School of Physics and Electronics, Hunan Key Laboratory for Super-Microstructure and Ultrafast Process, and Hunan Key Laboratory of Nanophotonics and Devices, Central South University, Changsha, 410083, People's Republic of China
| | - Yue Zhang
- School of Physics and Electronics, Hunan Key Laboratory for Super-Microstructure and Ultrafast Process, and Hunan Key Laboratory of Nanophotonics and Devices, Central South University, Changsha, 410083, People's Republic of China
| | - Mingzhen Mao
- School of Physics and Electronics, Hunan Key Laboratory for Super-Microstructure and Ultrafast Process, and Hunan Key Laboratory of Nanophotonics and Devices, Central South University, Changsha, 410083, People's Republic of China
| | - Lei Ma
- School of Physics and Electronics, Hunan Key Laboratory for Super-Microstructure and Ultrafast Process, and Hunan Key Laboratory of Nanophotonics and Devices, Central South University, Changsha, 410083, People's Republic of China
| | - Jianlin Chen
- Department of Pancreatic Surgery, Xiangya Hospital, Central South University, Changsha, 410008, China
- Department of General Surgery, Xiangya Hospital, Central South University, Changsha, 410008, China
| | - Long Zhang
- School of Physics and Electronics, Hunan Key Laboratory for Super-Microstructure and Ultrafast Process, and Hunan Key Laboratory of Nanophotonics and Devices, Central South University, Changsha, 410083, People's Republic of China
| | - Hui Wang
- School of Physics and Electronics, Hunan Key Laboratory for Super-Microstructure and Ultrafast Process, and Hunan Key Laboratory of Nanophotonics and Devices, Central South University, Changsha, 410083, People's Republic of China
| | - Hui Fan
- Hunan Provincial Key Laboratory of Advanced Materials for New Energy Storage and Conversion, School of Materials Science and Engineering, Hunan University of Science and Technology, Xiangtan, 411201, People's Republic of China
| | - Xiaohui Gao
- School of Physics and Electronics, Hunan Key Laboratory for Super-Microstructure and Ultrafast Process, and Hunan Key Laboratory of Nanophotonics and Devices, Central South University, Changsha, 410083, People's Republic of China
| | - Lianwen Deng
- School of Physics and Electronics, Hunan Key Laboratory for Super-Microstructure and Ultrafast Process, and Hunan Key Laboratory of Nanophotonics and Devices, Central South University, Changsha, 410083, People's Republic of China
| |
Collapse
|
19
|
Ghosh R, Li X, Yates MZ. Nonenzymatic Glucose Sensor Using Bimetallic Catalysts. ACS APPLIED MATERIALS & INTERFACES 2024; 16:17-29. [PMID: 38118131 PMCID: PMC10788829 DOI: 10.1021/acsami.3c10167] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/12/2023] [Revised: 11/25/2023] [Accepted: 11/28/2023] [Indexed: 12/22/2023]
Abstract
Bimetallic glucose oxidation electrocatalysts were synthesized by two electrochemical reduction reactions carried out in series onto a titanium electrode. Nickel was deposited in the first synthesis stage followed by either silver or copper in the second stage to form Ag@Ni and Cu@Ni bimetallic structures. The chemical composition, crystal structure, and morphology of the resulting metal coating of the titanium electrode were investigated by X-ray diffraction, energy-dispersive X-ray spectroscopy, X-ray photoelectron spectroscopy, and electron microscopy. The electrocatalytic performance of the coated titanium electrodes toward glucose oxidation was probed using cyclic voltammetry and amperometry. It was found that the unique high surface area bimetallic structures have superior electrocatalytic activity compared to nickel alone. The resulting catalyst-coated titanium electrode served as a nonenzymatic glucose sensor with high sensitivity and low limit of detection for glucose. The Cu@Ni catalyst enables accurate measurement of glucose over the concentration range of 0.2-12 mM, which includes the full normal human blood glucose range, with the maximum level extending high enough to encompass warning levels for prediabetic and diabetic conditions. The sensors were also found to perform well in the presence of several chemical compounds found in human blood known to interfere with nonenzymatic sensors.
Collapse
Affiliation(s)
- Rashmi Ghosh
- Department of Chemical Engineering, University of Rochester, Rochester, New York 14627, United States
| | - Xiao Li
- Department of Chemical Engineering, University of Rochester, Rochester, New York 14627, United States
| | - Matthew Z. Yates
- Department of Chemical Engineering, University of Rochester, Rochester, New York 14627, United States
| |
Collapse
|
20
|
Toda M, Sugiyama K, Sato F, Sasano Y, Fujimura T, Iwabuchi Y, Sato K. Electrochemical Characterization of a Novel Organoelectrocatalyst, 7-Azabicyclo[2.2.1]heptan-7-ol (ABHOL), and Its Application to Electrochemical Sensors. Chem Pharm Bull (Tokyo) 2024; 72:249-252. [PMID: 38432905 DOI: 10.1248/cpb.c23-00710] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/05/2024]
Abstract
Electrochemical enzyme sensors are suitable for simple monitoring methods, for example, as glucose sensors for diabetic patients; however, they have several disadvantages arising from the properties of the enzyme. Therefore, non-enzymatic electrochemical sensors using functional molecules are being developed. In this paper, we report the electrochemical characterization of a new hydroxylamine compound, 7-azabicyclo[2.2.1]heptan-7-ol (ABHOL), and its application to glucose sensing. Although the cyclic voltammogram for the first cycle was unstable, it was reproducible after the second cycle, enabling electrochemical analysis of ethanol and glucose. In the first cycle, ABHOL caused complex reactions, including electrochemical oxidation and comproportionation with the generated oxoammonium ions. The electrochemical probe performance of ABHOL was more efficient than the typical nitroxyl radical compound, 2,2,6,6-tetramethylpiperidine-1-oxyl (TEMPO), and had similar efficiency to 9-azabicyclo[3.3.1]nonane N-oxyl (ABNO), which is activated by the bicyclic structure. The results demonstrated the advantages of ABHOL, which can be synthesized from inexpensive materials via simple methods.
Collapse
Affiliation(s)
- Masaki Toda
- Graduate School of Pharmaceutical Sciences, Tohoku University
| | - Kyoko Sugiyama
- Faculty of Pharmaceutical Science, Tohoku Medical and Pharmaceutical University
| | - Fumiya Sato
- Faculty of Pharmaceutical Science, Tohoku Medical and Pharmaceutical University
| | - Yusuke Sasano
- Graduate School of Pharmaceutical Sciences, Tohoku University
| | - Tsutomu Fujimura
- Faculty of Pharmaceutical Science, Tohoku Medical and Pharmaceutical University
| | | | - Katsuhiko Sato
- Faculty of Pharmaceutical Science, Tohoku Medical and Pharmaceutical University
| |
Collapse
|
21
|
Guati C, Gómez-Coma L, Fallanza M, Ortiz I. Optimized Copper-Based Microfeathers for Glucose Detection. BIOSENSORS 2023; 13:1032. [PMID: 38131792 PMCID: PMC10741577 DOI: 10.3390/bios13121032] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/08/2023] [Revised: 12/04/2023] [Accepted: 12/07/2023] [Indexed: 12/23/2023]
Abstract
Diabetes is expected to rise substantially by 2045, prompting extensive research into accessible glucose electrochemical sensors, especially those based on non-enzymatic materials. In this context, advancing the knowledge of stable metal-based compounds as alternatives to non-enzymatic sensors becomes a scientific challenge. Nonetheless, these materials have encountered difficulties in maintaining stable responses under physiological conditions. This work aims to advance knowledge related to the synthesis and characterization of copper-based electrodes for glucose detection. The microelectrode presented here exhibits a wide linear range and a sensitivity of 1009 µA∙cm-2∙mM-1, overperfoming the results reported in literature so far. This electrode material has also demonstrated outstanding results in terms of reproducibility, repeatability, and stability, thereby meeting ISO 15197:2015 standards. Our study guides future research on next-generation sensors that combine copper with other materials to enhance activity in neutral media.
Collapse
Affiliation(s)
| | | | | | - Inmaculada Ortiz
- Chemical and Biomolecular Engineering Department, University of Cantabria, 39005 Santander, Spain; (C.G.); (L.G.-C.); (M.F.)
| |
Collapse
|
22
|
Maduraiveeran G. Enzyme-free electrochemical sensor platforms based on transition metal nanostructures for clinical diagnostics. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2023; 15:6620-6630. [PMID: 38047319 DOI: 10.1039/d3ay01849k] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/05/2023]
Abstract
The detection of emergent biomarkers is of key significance in numerous clinical, biological, and biomedical fields. Specifically, the design and development of potent electrochemical lactic acid and glucose sensing platforms are especially in great demand in a variety of industries, including those involved in clinical analysis, biomedicine, biological, food, cosmetics, pharmaceuticals, leather, sports, and chemical industries. Nanostructured transition metal-derived materials have opened the door to electrochemical sensors and biosensors due to their advantages of high surface-to-volume ratio, surface reaction activity, catalytic activity, and strong adsorption capability. The primary aim of the present minireview is to highlight the advancement of enzyme-free electrochemical sensor platforms based on transition metal-derived nanostructures with high electrocatalytic activity and sensing performance towards lactic acid and glucose in practical samples. The preparation approaches, structural and composition monitoring, fabrication of sensing electrodes, catalytic activity, sensing performance in real samples, and the exploration of sensing mechanisms are majorly concentrated on in most of our recent research studies. Moreover, state-of-the-art transition metal-derived nanostructure-derived electrochemical sensor platforms, critical comparison of the analytical performance of the sensor platforms, and the future perspectives of the enzyme-free electrochemical sensor for clinical diagnostics are described.
Collapse
Affiliation(s)
- Govindhan Maduraiveeran
- Materials Electrochemistry Laboratory, Department of Chemistry, Faculty of Engineering and Technology, SRM Institute of Science and Technology, Kattankulathur 603 203, Chengalpattu, Tamil Nadu, India.
| |
Collapse
|
23
|
Jiang D, Liu T, Chu Z, Wang Y. Advances in nanostructured material-based non-enzymatic electrochemical glucose sensors. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2023; 15:6344-6361. [PMID: 37971394 DOI: 10.1039/d3ay01664a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/19/2023]
Abstract
Non-enzymatic electrochemical sensors that use functional materials to directly catalyze glucose have shown great promise in diabetes management, food control, and bioprocess inspection owing to the advantages of high sensitivity, long-term stability, and low cost. Recently, in order to produce enhanced electrochemical behavior, significant efforts have been devoted to the preparation of functional materials with regular nanostructure, as it provides high specific surface area and well-defined strong active sites for electrochemical sensing. However, the structure-performance correlation in this field has not been reviewed thoroughly in the literature. This review aims to present a comprehensive report on advanced zero- to three-dimensional nanostructures based on the geometric feature and to discuss in depth their structural effects on enzyme-free electrochemical detection of glucose. It starts by illustrating the sensing principles of nanostructured materials, followed by a detailed discussion on the structural effects related to the features of each dimension. The structure-performance correlation is explored by comparing the performance derived from diverse dimensional architectures, which is beneficial for the better design of regular nanostructure to achieve efficient enzyme-free sensing of glucose. Finally, future directions of non-enzymatic electrochemical glucose sensors to solve emerging challenges and further improve the sensing performance are also proposed.
Collapse
Affiliation(s)
- Danfeng Jiang
- Engineering Research Center of Clinical Functional Materials and Diagnosis & Treatment Devices of Zhejiang Province, Wenzhou Institute, University of Chinese Academy of Sciences, Wenzhou, Zhejiang 325001, PR China.
- School of Environmental and Chemical Engineering, Jiangsu University of Science and Technology, Zhenjiang, Jiangsu 212003, PR China.
| | - Tao Liu
- State Key Laboratory of Materials-Oriented Chemical Engineering, College of Chemical Engineering, Nanjing Tech University, Nanjing, Jiangsu 211816, PR China.
| | - Zhenyu Chu
- Engineering Research Center of Clinical Functional Materials and Diagnosis & Treatment Devices of Zhejiang Province, Wenzhou Institute, University of Chinese Academy of Sciences, Wenzhou, Zhejiang 325001, PR China.
- State Key Laboratory of Materials-Oriented Chemical Engineering, College of Chemical Engineering, Nanjing Tech University, Nanjing, Jiangsu 211816, PR China.
| | - Yi Wang
- Engineering Research Center of Clinical Functional Materials and Diagnosis & Treatment Devices of Zhejiang Province, Wenzhou Institute, University of Chinese Academy of Sciences, Wenzhou, Zhejiang 325001, PR China.
- School of Biomedical Engineering, School of Ophthalmology and Optometry, Eye Hospital, Wenzhou Medical University, Wenzhou, Zhejiang 325001, PR China
| |
Collapse
|
24
|
Bagheri R, Alikhani S, Miri-Moghaddam E. Fabrication of conductive Ag/AgCl/Ag nanorods ink on Laser-induced graphene electrodes on flexible substrates for non-enzymatic glucose detection. Sci Rep 2023; 13:20898. [PMID: 38017145 PMCID: PMC10684547 DOI: 10.1038/s41598-023-48322-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2023] [Accepted: 11/24/2023] [Indexed: 11/30/2023] Open
Abstract
An unusual strategy was designed to fabricate conductive patterns for flexible surfaces, which were utilized for non-enzymatic amperometric glucose sensors. The Ag/AgCl/Ag quasi-reference ink formulation utilized two reducing agents, NaBH[Formula: see text] and ethylene glycol. The parameters of the ink, such as sintering time and temperature, NaBH[Formula: see text] concentration, and layer number of coatings on flexible laser-induced graphene (LIG) electrodes were investigated. The conductive Ag/AgCl/Ag ink was characterized using electrochemical and surface analysis techniques. The electrocatalytic activity of Ag/AgCl/Ag NRs can be attributed to their high surface area, which offer numerous active sites for catalytic reactions. The selectivity and sensitivity of the electrodes for glucose detection were investigated. The XRD analysis showed (200) oriented AgCl on covered Ag NRs, and with the addition of NaBH[Formula: see text], the intensity of the peaks of the Ag NRs increased. The wide linear range of non-enzymatic sensors was attained from 0.003 to 0.18 mM and 0.37 to 5.0 mM, with a low limit of detection of 10 [Formula: see text]M and 20 [Formula: see text]M, respectively.The linear range of enzymatic sensor in real sample was determined from 0.040 to 0.097 mM with a detection limit of 50 [Formula: see text]M. Furthermore, results of the interference studies demonstrated excellent selectivity of the Ag/AgCl/Ag NRs/LIG electrode. The Ag/AgCl/Ag NRs on the flexible LIG electrode exhibited excellent sensitivity,long-time stablity,and reproducibility. The efficient electroactivity were deemed suitable for various electrochemical applications and biosensors.
Collapse
Affiliation(s)
- Rana Bagheri
- Department of Molecular Medicine, Faculty of Medicine, Cardiovascular Diseases Research Center, Birjand University of Medical Sciences, Birjand, 9717853577, Iran
- Nanofanavaran partopooyesh Company, Science and Technology Park of South Khorasan, Birjand, 9718643683, Iran
| | - Saeid Alikhani
- Nanofanavaran partopooyesh Company, Science and Technology Park of South Khorasan, Birjand, 9718643683, Iran
| | - Ebrahim Miri-Moghaddam
- Department of Molecular Medicine, Faculty of Medicine, Cardiovascular Diseases Research Center, Birjand University of Medical Sciences, Birjand, 9717853577, Iran.
| |
Collapse
|
25
|
Zalke JB, Narkhede NP, Pandhurnekar CP, Rotake DR, Singh SG. Non-enzymatic glucose detection with screen-printed chemiresistive sensor using green synthesised silver nanoparticle and multi-walled carbon nanotubes-zinc oxide nanofibers. NANOTECHNOLOGY 2023; 35:065502. [PMID: 37918017 DOI: 10.1088/1361-6528/ad090c] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/10/2023] [Accepted: 11/01/2023] [Indexed: 11/04/2023]
Abstract
Non-enzymatic screen-printed chemiresistive interdigitated electrodes (SPCIE) were designed and fabricated using a low-cost screen-printing method for detection of the glucose. The interdigitated electrodes (IDE) pattern was printed using conductive graphene ink on the glossy surface of the photo paper. The proposed glossy photo paper-based SPCIE are functionalized with multi-walled carbon nanotubes-zinc oxide (MWCNTs-ZnO) nanofibers to create the chemiresistive matrix. Further, to bind these nanofibers with the graphene electrode surface, we have used the green synthesized silver nanoparticles (AgNPs) with banana flower stem fluid (BFSF) as a binder solution. AgNPs with BFSF form the conductive porous natural binder layer (CPNBL). It does not allow to increase the resistivity of the deposited material on graphene electrodes and also keeps the nanofibers intact with paper-based SPCIE. The synthesized material of MWCNT-ZnO nanofibers and green synthesized AgNPs with BFSF as a binder were characterized by Ultraviolet-visible spectroscopy (UV-vis), scanning electron microscope (SEM), x-ray diffraction (XRD), and Fourier-transform infrared spectroscopy (FTIR). The amperometric measurements were performed on the proposed SPCIE sensor to detect the glucose sample directly. The innovative paper-based SPCIE glucose sensor exhibits a linear corelation between current measurements and glucose concentration in the range between 45.22μm and 20 mm, with a regression coefficient (R2) of 0.9902 and a lower limit of detection (LoD) of 45.22μm (n= 5). The sensitivity of the developed SPCIE sensor was 2178.57μAmM-1cm-2, and the sensor's response time determined was approximately equal to 18 s. The proposed sensor was also tested for real blood serum sample, and relative standard deviation (RSD) was found equal to 2.95%.
Collapse
Affiliation(s)
- Jitendra B Zalke
- Department of Electronics Design Technology, Shri Ramdeobaba College of Engineering and Management, Nagpur, India
| | - N P Narkhede
- Department of Electronics Engineering, Shri Ramdeobaba College of Engineering and Management, Nagpur, India
| | - C P Pandhurnekar
- Department of Chemistry, Shri Ramdeobaba College of Engineering and Management, Nagpur, India
| | - Dinesh R Rotake
- Department of Electrical Engineering, Indian Institute of Technology, Hyderabad, India
| | - Shiv Govind Singh
- Department of Electrical Engineering, Indian Institute of Technology, Hyderabad, India
| |
Collapse
|
26
|
Kim SE, Yoon JC, Tae HJ, Muthurasu A. Electrospun Manganese-Based Metal-Organic Frameworks for MnO x Nanostructures Embedded in Carbon Nanofibers as a High-Performance Nonenzymatic Glucose Sensor. ACS OMEGA 2023; 8:42689-42698. [PMID: 38024713 PMCID: PMC10652823 DOI: 10.1021/acsomega.3c05459] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/26/2023] [Revised: 10/15/2023] [Accepted: 10/17/2023] [Indexed: 12/01/2023]
Abstract
Material-specific electrocatalytic activity and electrode design are essential factors in evaluating the performance of electrochemical sensors. Herein, the technique described involves electrospinning manganese-based metal-organic frameworks (Mn-MOFs) to develop MnOx nanostructures embedded in carbon nanofibers. The resulting structure features an electrocatalytic material for an enzyme-free glucose sensor. The elemental composition, morphology, and microstructure of the fabricated electrodes materials were characterized by using energy-dispersive X-ray spectroscopy (EDX), field-emission scanning electron microscopy (FESEM), and transmission electron microscopy (TEM). Cyclic voltammetry (CV) and amperometric i-t (current-time) techniques are characteristically employed to assess the electrochemical performance of materials. The MOF MnOx-CNFs nanostructures significantly improve detection performance for nonenzymatic amperometric glucose sensors, including a broad linear range (0 mM to 9.1 mM), high sensitivity (4080.6 μA mM-1 cm-2), a low detection limit (0.3 μM, S/N = 3), acceptable selectivity, outstanding reproducibility, and stability. The strategy of metal and metal oxide-integrated CNF nanostructures based on MOFs opens interesting possibilities for the development of high-performance electrochemical sensors.
Collapse
Affiliation(s)
- So Eun Kim
- Department
of Emergency Medicine, Research Institute
of Clinical Medicine of Jeonbuk National University and Biomedical
Research Institute of Jeonbuk National University Hospital, Jeonju 54907, Republic of Korea
| | - Jae Chol Yoon
- Department
of Emergency Medicine, Research Institute
of Clinical Medicine of Jeonbuk National University and Biomedical
Research Institute of Jeonbuk National University Hospital, Jeonju 54907, Republic of Korea
| | - Hyun-Jin Tae
- College
of Veterinary Medicine and Biosafety Research Institute, Jeonbuk National University, Iksan 54596, Republic of Korea
| | - Alagan Muthurasu
- Department
of Nano Convergence Technology, Jeonbuk
National University, Jeonju 54907, Republic
of Korea
| |
Collapse
|
27
|
Zhu J, Wang F, Chen J, Liu C. An efficient biosensor using a functionalized microneedle of Cu 2O-based CoCu-LDH for glucose detection. RSC Adv 2023; 13:32558-32566. [PMID: 37936640 PMCID: PMC10626343 DOI: 10.1039/d3ra05957j] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2023] [Accepted: 10/23/2023] [Indexed: 11/09/2023] Open
Abstract
Glucose detection with small and micro volume sampling has recently received increasing attention in monitoring personal health. Herein, a cauliflower-type cluster of Cu2O nanoparticles (NPs) was directly deposited on the tip surface of a stainless steel acupuncture needle electrode (ANE) by electrochemical deposition, and then this pre-formed cuprous basis was used to further prepare the neatly arranged CoCu-layered double hydroxide (CoCu-LDH) nanosheets that interconnected to form nano-sized pores in the range from 100 to 500 nm. The microstructure and spectral characteristics of the surface modification materials were comprehensively characterized by FE-SEM, EDS, XRD, FT-IR and TEM. Cu2O-based CoCu-LDH composites with special morphology had been proven to accelerate the rate of electron transport and provide more available active centers, and moreover, the mixed valence of Cu/Co induced an excellent synergism for the electrocatalytic oxidation of glucose. As a result, CoCu-LDH/Cu2O/ANE as a sensitive glucose probe exhibited two wider linear ranges of 0.03-0.40 mM and 0.40-6.00 mM, with sensitivities of 116.13 μA mM-1 and 52.08 μA mM-1, respectively, and the detection limit as low as 0.46 μM (S/N = 3). The response time only took 3 s and it kept working stably in the interference of ascorbic acid (AA), dopamine (DA), uric acid (UA), and Cl-. In the stability test, the CoCu-LDH/Cu2O/ANE sensor exhibited a stable monitoring sensitivity after 15 days. Finally, the CoCu-LDH/Cu2O/ANE sensor had been successfully applied to glucose analysis in human serum, proving that our design was an attractive strategy for developing a portable, minimally invasive, and low-cost non-enzymatic electrochemical glucose sensing platform.
Collapse
Affiliation(s)
- Jialei Zhu
- College of Pharmacy, Jinzhou Medical University Jinzhou Liaoning P. R. China
| | - Fuqin Wang
- College of Pharmacy, Jinzhou Medical University Jinzhou Liaoning P. R. China
| | - Jiaying Chen
- College of Pharmacy, Jinzhou Medical University Jinzhou Liaoning P. R. China
| | - Chang Liu
- College of Pharmacy, Jinzhou Medical University Jinzhou Liaoning P. R. China
| |
Collapse
|
28
|
Lu W, Zhang R, Zhang X, Shi Y, Wang Y, Shi H. Synthesis of uniformly dispersed Fe 2TiO 5 nanodisks: a sensitive photoelectrochemical sensor for glucose monitoring in human blood serum. Analyst 2023; 148:5469-5475. [PMID: 37750726 DOI: 10.1039/d3an01265d] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/27/2023]
Abstract
A novel photoelectrochemical (PEC) sensor was constructed, using Fe2TiO5 nanodisks under visible-light irradiation, for the determination of glucose in human blood serum. The uniformly dispersed Fe2TiO5 nanodisks were synthesized for the first time by an ion exchange method and subsequent heat treatment. As excellent catalysts, the Fe2TiO5 nanodisks can directly catalyze the oxidation of glucose to produce current in the absence of glucose oxidase. Compared with commercial TiO2, the Fe2TiO5 nanodisks exhibit better activity in the electrocatalytic oxidation of glucose and can generate a photocurrent as a signal for glucose detection. The PEC sensor shows a wide linear range (4 μM-10 mM), a low limit of detection (0.588 μM) and a super sensitivity of 2653 μA mM-1 cm-2, which are much better than similar configurations reported previously. This PEC sensor has been successfully used to monitor glucose in human blood serum. Moreover, this PEC glucose sensor based on Fe2TiO5 nanodisks possesses great potential for application in point-of-care clinical diagnosis.
Collapse
Affiliation(s)
- Wenbo Lu
- Key Laboratory of Magnetic Molecules and Magnetic Information Materials (Ministry of Education), School of Chemistry and Material Science, Shanxi Normal University, Taiyuan 030031, China.
| | - Rui Zhang
- Key Laboratory of Magnetic Molecules and Magnetic Information Materials (Ministry of Education), School of Chemistry and Material Science, Shanxi Normal University, Taiyuan 030031, China.
| | - Xue Zhang
- Key Laboratory of Magnetic Molecules and Magnetic Information Materials (Ministry of Education), School of Chemistry and Material Science, Shanxi Normal University, Taiyuan 030031, China.
| | - Yufen Shi
- Key Laboratory of Magnetic Molecules and Magnetic Information Materials (Ministry of Education), School of Chemistry and Material Science, Shanxi Normal University, Taiyuan 030031, China.
| | - Yupeng Wang
- Key Laboratory of Magnetic Molecules and Magnetic Information Materials (Ministry of Education), School of Chemistry and Material Science, Shanxi Normal University, Taiyuan 030031, China.
| | - Huanhuan Shi
- Institut für Quanten Materialien und Technologien, Karlsruher Institut für Technologie, Hermann-v.-Helmholtz-Platz 1, 76344, Eggenstein-Leopoldshafen, Germany.
| |
Collapse
|
29
|
Wang L, Guo GZ, Wang M, Ruan HY, Wu YP, Wu XQ, Zhang QC, Li DS. Ultrafast Response in Nonenzymatic Electrochemical Glucose Sensing with Ni(II)-MOFs by Dimensional Manipulation. Inorg Chem 2023; 62:16426-16434. [PMID: 37750677 DOI: 10.1021/acs.inorgchem.3c02107] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/27/2023]
Abstract
Metal-organic frameworks (MOFs) are emerging as promising candidates for electrochemical glucose sensing owing to their ordered channels, tunable chemistry, and atom-precision metal sites. Herein, the efficient nonenzymatic electrochemical glucose sensing is achieved by taking advantage of Ni(II)-based metal-organic frameworks (Ni(II)-MOFs) and acquiring the ever-reported fastest response time. Three Ni(II)-MOFs ({[Ni6L2(H2O)26]4H2O}n (CTGU-33), {Ni(bib)1/2(H2L)1/2(H2O)3}n (CTGU-34), {Ni(phen)(H2L)1/2(H2O)2}n (CTGU-35)) have been synthesized for the first time, which use benzene-1,2,3,4,5,6-hexacarboxylic acid (H6L) as an organic ligand and introduce 1,4-bis(1-imidazoly)benzene (bib) or 1,10-phenanthroline (phen) as spatially auxiliary ligands. Bib and phen convert the coordination mode of CTGU-33, affording structural dimensions from 2D of CTGU-33 to 3D of CTGU-34 or 1D of CTGU-35. By tuning the dimension of the skeleton, CTGU-34 with 3D interconnected channels exhibits an ultrafast response of less than 0.4 s, which is superior to the existing nonenzymatic electrochemical sensors. Additionally, a low detection limit of 0.12 μM (S/N = 3) and a high sensitivity of 1705 μA mM-1 cm-2 are simultaneously achieved. CTGU-34 further showcases desirable anti-interference and cycling stability, which demonstrates a promising application prospect in the real-time detection of glucose.
Collapse
Affiliation(s)
- Le Wang
- College of Materials and Chemical Engineering, Key Laboratory of Inorganic Nonmetallic Crystalline and Energy Conversion Materials, China Three Gorges University, Yichang 443002, Hubei, P. R. China
- Hubei Three Gorges Laboratory, Yichang 443007, Hubei, P. R. China
| | - Gui-Zhi Guo
- College of Materials and Chemical Engineering, Key Laboratory of Inorganic Nonmetallic Crystalline and Energy Conversion Materials, China Three Gorges University, Yichang 443002, Hubei, P. R. China
- Hanchuan Experimental Senior High School, Hanchuan 432300, Hubei, P. R. China
| | - Meidi Wang
- College of Materials and Chemical Engineering, Key Laboratory of Inorganic Nonmetallic Crystalline and Energy Conversion Materials, China Three Gorges University, Yichang 443002, Hubei, P. R. China
- Hubei Three Gorges Laboratory, Yichang 443007, Hubei, P. R. China
| | - Heng-Yu Ruan
- College of Materials and Chemical Engineering, Key Laboratory of Inorganic Nonmetallic Crystalline and Energy Conversion Materials, China Three Gorges University, Yichang 443002, Hubei, P. R. China
| | - Ya-Pan Wu
- College of Materials and Chemical Engineering, Key Laboratory of Inorganic Nonmetallic Crystalline and Energy Conversion Materials, China Three Gorges University, Yichang 443002, Hubei, P. R. China
- Hubei Three Gorges Laboratory, Yichang 443007, Hubei, P. R. China
| | - Xue-Qian Wu
- College of Materials and Chemical Engineering, Key Laboratory of Inorganic Nonmetallic Crystalline and Energy Conversion Materials, China Three Gorges University, Yichang 443002, Hubei, P. R. China
- Hubei Three Gorges Laboratory, Yichang 443007, Hubei, P. R. China
| | - Qi-Chun Zhang
- College of Materials and Chemical Engineering, Key Laboratory of Inorganic Nonmetallic Crystalline and Energy Conversion Materials, China Three Gorges University, Yichang 443002, Hubei, P. R. China
| | - Dong-Sheng Li
- College of Materials and Chemical Engineering, Key Laboratory of Inorganic Nonmetallic Crystalline and Energy Conversion Materials, China Three Gorges University, Yichang 443002, Hubei, P. R. China
- Hubei Three Gorges Laboratory, Yichang 443007, Hubei, P. R. China
| |
Collapse
|
30
|
Fang Q, Wang H, Wei X, Tang Y, Luo X, Xu W, Hu L, Gu W, Zhu C. Cu Aerogels with Sustainable Cu(I)/Cu(II) Redox Cycles for Sensitive Nonenzymatic Glucose Sensing. Adv Healthc Mater 2023; 12:e2301073. [PMID: 37285868 DOI: 10.1002/adhm.202301073] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2023] [Revised: 06/05/2023] [Indexed: 06/09/2023]
Abstract
Developing functional nanomaterials for nonenzymatic glucose electrochemical sensing platforms is vital and challenging from the perspective of pathology and physiology. Accurate identification of active sites and thorough investigation of catalytic mechanisms are critical prerequisites for the design of advanced catalysts for electrochemical sensing. Herein, Cu aerogels are synthesized as a model system for sensitive nonenzymatic glucose sensing. The resultant Cu aerogels exhibit good catalytic activity for glucose electrooxidation with high sensitivity and a low detection limit. Significantly, in situ electrochemical investigations and Raman characterizations reveal the catalytic mechanism of Cu-based nonenzymatic glucose sensing. During the electrocatalytic oxidation of glucose, Cu(I) is electrochemically oxidized to generate Cu(II), and the resultant Cu(II) is spontaneously reduced back to Cu(I) by glucose, achieving the sustained Cu(I)/Cu(II) redox cycles. This study provides profound insights into the catalytic mechanism for nonenzymatic glucose sensing, which provides great potential guidance for a rational design of advanced catalysts in the future.
Collapse
Affiliation(s)
- Qie Fang
- National Key Laboratory of Green Pesticide, International Joint Research Center for Intelligent Biosensing Technology and Health, College of Chemistry, Central China Normal University, Wuhan, 430079, P. R. China
| | - Hengjia Wang
- National Key Laboratory of Green Pesticide, International Joint Research Center for Intelligent Biosensing Technology and Health, College of Chemistry, Central China Normal University, Wuhan, 430079, P. R. China
| | - Xiaoqian Wei
- National Key Laboratory of Green Pesticide, International Joint Research Center for Intelligent Biosensing Technology and Health, College of Chemistry, Central China Normal University, Wuhan, 430079, P. R. China
| | - Yinjun Tang
- National Key Laboratory of Green Pesticide, International Joint Research Center for Intelligent Biosensing Technology and Health, College of Chemistry, Central China Normal University, Wuhan, 430079, P. R. China
| | - Xin Luo
- National Key Laboratory of Green Pesticide, International Joint Research Center for Intelligent Biosensing Technology and Health, College of Chemistry, Central China Normal University, Wuhan, 430079, P. R. China
| | - Weiqing Xu
- National Key Laboratory of Green Pesticide, International Joint Research Center for Intelligent Biosensing Technology and Health, College of Chemistry, Central China Normal University, Wuhan, 430079, P. R. China
| | - Liuyong Hu
- Hubei Key Laboratory of Plasma Chemistry and Advanced Materials, Hubei Engineering Technology Research Center of Optoelectronic and New Energy Materials, Wuhan Institute of Technology, Wuhan, 430205, P. R. China
| | - Wenling Gu
- National Key Laboratory of Green Pesticide, International Joint Research Center for Intelligent Biosensing Technology and Health, College of Chemistry, Central China Normal University, Wuhan, 430079, P. R. China
| | - Chengzhou Zhu
- National Key Laboratory of Green Pesticide, International Joint Research Center for Intelligent Biosensing Technology and Health, College of Chemistry, Central China Normal University, Wuhan, 430079, P. R. China
| |
Collapse
|
31
|
Morozov R, Stanković D, Avdin V, Zherebtsov D, Romashov M, Selezneva A, Uchaev D, Senin A, Chernukha A. The Effect of Rare-Earth Elements on the Morphological Aspect of Borate and Electrocatalytic Sensing of Biological Compounds. BIOSENSORS 2023; 13:901. [PMID: 37887094 PMCID: PMC10605444 DOI: 10.3390/bios13100901] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/21/2023] [Revised: 09/07/2023] [Accepted: 09/14/2023] [Indexed: 10/28/2023]
Abstract
Adjusting the morphological characteristics of a material can result in improved electrocatalytic capabilities of the material itself. An example of this is the introduction of rare-earth elements into the borate structure, which gives a new perspective on the possibilities of this type of material in the field of (bio)sensing. In this paper, we present the preparation of borates including La, Nd and Dy and their application for the modification of a glassy carbon electrode, which is used for the non-enzymatic detection of a biologically relevant molecule, vitamin B6 (pyridoxine). Compared with the others, dysprosium borate has the best electrocatalytic performance, showing the highest current and the lowest impedance, respectively, as determined using cyclic voltammetry and impedance tests. Quantitative testing of B6 was performed in DPV mode in a Britton-Robinson buffer solution with a pH of 6 and an oxidation potential of about +0.8 V. The calibration graph for the evaluation of B6 has a linear range from 1 to 100 μM, with a correlation coefficient of 0.9985 and a detection limit of 0.051 μM. The DyBO3-modified electrode can be used repeatedly, retaining more than 90% of the initial signal level after six cycles. The satisfactory selectivity offered a potential practical application of the chosen method for the monitoring of pyridoxine in artificially prepared biological fluids with acceptable recovery. In light of all the obtained results, this paper shows an important approach for the successful design of electrocatalysts with tuned architecture and opens new strategies for the development of materials for the needs of electrochemical (bio)sensing.
Collapse
Affiliation(s)
- Roman Morozov
- Nanotechnology Research Center, South Ural State University, 454080 Chelyabinsk, Russia; (R.M.); (V.A.); (D.Z.); (M.R.); (A.S.); (D.U.); (A.S.); (A.C.)
| | - Dalibor Stanković
- Faculty of Chemistry, University of Belgrade, 11000 Belgrade, Serbia
| | - Viacheslav Avdin
- Nanotechnology Research Center, South Ural State University, 454080 Chelyabinsk, Russia; (R.M.); (V.A.); (D.Z.); (M.R.); (A.S.); (D.U.); (A.S.); (A.C.)
| | - Dmitri Zherebtsov
- Nanotechnology Research Center, South Ural State University, 454080 Chelyabinsk, Russia; (R.M.); (V.A.); (D.Z.); (M.R.); (A.S.); (D.U.); (A.S.); (A.C.)
| | - Mikhail Romashov
- Nanotechnology Research Center, South Ural State University, 454080 Chelyabinsk, Russia; (R.M.); (V.A.); (D.Z.); (M.R.); (A.S.); (D.U.); (A.S.); (A.C.)
| | - Anastasia Selezneva
- Nanotechnology Research Center, South Ural State University, 454080 Chelyabinsk, Russia; (R.M.); (V.A.); (D.Z.); (M.R.); (A.S.); (D.U.); (A.S.); (A.C.)
| | - Daniil Uchaev
- Nanotechnology Research Center, South Ural State University, 454080 Chelyabinsk, Russia; (R.M.); (V.A.); (D.Z.); (M.R.); (A.S.); (D.U.); (A.S.); (A.C.)
| | - Anatoly Senin
- Nanotechnology Research Center, South Ural State University, 454080 Chelyabinsk, Russia; (R.M.); (V.A.); (D.Z.); (M.R.); (A.S.); (D.U.); (A.S.); (A.C.)
| | - Alexander Chernukha
- Nanotechnology Research Center, South Ural State University, 454080 Chelyabinsk, Russia; (R.M.); (V.A.); (D.Z.); (M.R.); (A.S.); (D.U.); (A.S.); (A.C.)
| |
Collapse
|
32
|
Zhang T, Lu R, Wang G, Sun X, Li J, Mizaikoff B. Glucose sandwich assay based on surface-enhanced Raman spectroscopy. Analyst 2023; 148:4310-4317. [PMID: 37470091 DOI: 10.1039/d3an00481c] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/21/2023]
Abstract
A facile and sensitive glucose sandwich assay using surface-enhanced Raman scattering (SERS) has been developed. Glucose was captured by 3-aminopheyonyl boronic acid (APBA) modified Ag nanoparticles decorated onto a polyamide surface. Then, Ag nanoparticles modified with 3-amino-6-ethynylpicolinonitrile (AEPO) and APBA were used as SERS tags. APBA forms specific cis-diol compounds with glucose molecules avoiding interference by other saccharides and biomolecules in urine enabling its selective detection. As the actual Raman reporter, AEPO exhibited a distinctive SERS peak in the Raman silent region, thus increasing the sensitivity of the glucose detection to 10-11 M. Additionally, the developed SERS assay was reusable, and its applicability in artificial urine samples demonstrated future clinical utility confirming the potential of this innovative technology as a diagnostic tool for glucose sensing.
Collapse
Affiliation(s)
- Tingting Zhang
- Jiangsu Key Laboratory of Chemical Pollution Control and Resources Reuse, School of Environmental and Biological Engineering, Nanjing University of Science and Technology, Nanjing 210094, People's Republic of China.
| | - Rui Lu
- Jiangsu Key Laboratory of Chemical Pollution Control and Resources Reuse, School of Environmental and Biological Engineering, Nanjing University of Science and Technology, Nanjing 210094, People's Republic of China.
| | - Gongying Wang
- Jiangsu Key Laboratory of Chemical Pollution Control and Resources Reuse, School of Environmental and Biological Engineering, Nanjing University of Science and Technology, Nanjing 210094, People's Republic of China.
| | - Xiuyun Sun
- Jiangsu Key Laboratory of Chemical Pollution Control and Resources Reuse, School of Environmental and Biological Engineering, Nanjing University of Science and Technology, Nanjing 210094, People's Republic of China.
| | - Jiansheng Li
- Jiangsu Key Laboratory of Chemical Pollution Control and Resources Reuse, School of Environmental and Biological Engineering, Nanjing University of Science and Technology, Nanjing 210094, People's Republic of China.
| | - Boris Mizaikoff
- Institute of Analytical and Bioanalytical Chemistry, Ulm University, Albert Einstein Allee 11, 89081 Ulm, Germany
- Hahn-Schickard, Ulm Sedanstrasse 14, 89077 Ulm, Germany.
| |
Collapse
|
33
|
Sun M, Cui C, Chen H, Wang D, Zhang W, Guo W. Enzymatic and Non-Enzymatic Uric Acid Electrochemical Biosensors: A Review. Chempluschem 2023; 88:e202300262. [PMID: 37551133 DOI: 10.1002/cplu.202300262] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2023] [Revised: 07/27/2023] [Accepted: 08/07/2023] [Indexed: 08/09/2023]
Abstract
In recent years, the development of electrochemical biosensors for uric acid has made great achievements. Firstly, uric acid electrochemical biosensors were classified according to their reaction mechanism. Then, the reaction mechanism of the uric acid sensor and the application of nano-modified materials were deeply analyzed from the perspective of non-enzyme and enzymes. In this paper, the catalytic oxidation capacity, enzyme adsorption effect, conductivity, robustness, detection range, and detection limit of uric acid sensors were discussed and compared. Finally, the advantages of acid-sensitive electrochemical biosensors were summarized, and the constructive recommendations were proposed for improving the deficiencies of acid biosensors. The potential for further development in this area was also discussed.
Collapse
Affiliation(s)
- Miao Sun
- North China University of Science and Technology, College of Electrical Engineering, Tangshan, 063210, P. R. China
| | - Chuanjin Cui
- North China University of Science and Technology, College of Electrical Engineering, Tangshan, 063210, P. R. China
| | - Hongshuo Chen
- North China University of Science and Technology, College of Electrical Engineering, Tangshan, 063210, P. R. China
| | - Dengling Wang
- North China University of Science and Technology, College of Electrical Engineering, Tangshan, 063210, P. R. China
| | - Wensi Zhang
- North China University of Science and Technology, College of Electrical Engineering, Tangshan, 063210, P. R. China
| | - Wenjin Guo
- North China University of Science and Technology, College of Electrical Engineering, Tangshan, 063210, P. R. China
| |
Collapse
|
34
|
Hu J, Dai J, Huang C, Zeng X, Wei W, Wang Z, Lin P. Organic Electrochemical Transistor with MoS 2 Nanosheets Modified Gate Electrode for Sensitive Glucose Sensing. SENSORS (BASEL, SWITZERLAND) 2023; 23:7449. [PMID: 37687905 PMCID: PMC10490818 DOI: 10.3390/s23177449] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/03/2023] [Revised: 08/22/2023] [Accepted: 08/22/2023] [Indexed: 09/10/2023]
Abstract
An organic electrochemical transistor (OECT) with MoS2 nanosheets modified on the gate electrode was proposed for glucose sensing. MoS2 nanosheets, which had excellent electrocatalytic performance, a large specific surface area, and more active sites, were prepared by liquid phase ultrasonic exfoliation to modify the gate electrode of OECT, resulting in a large improvement in the sensitivity of the glucose sensor. The detection limit of the device modified with MoS2 nanosheets is down to 100 nM, which is 1~2 orders of magnitude better than that of the device without nanomaterial modification. This result manifests not only a sensitive and selective method for the detection of glucose based on OECT but also an extended application of MoS2 nanosheets for other biomolecule sensing with high sensitivity.
Collapse
Affiliation(s)
- Jin Hu
- Shenzhen Key Laboratory of Special Functional Materials & Guangdong Research Center for Interfacial Engineering of Functional Materials, College of Materials Science and Engineering, Shenzhen University, Shenzhen 518060, China; (J.H.); (J.D.); (C.H.); (X.Z.)
| | - Jiajia Dai
- Shenzhen Key Laboratory of Special Functional Materials & Guangdong Research Center for Interfacial Engineering of Functional Materials, College of Materials Science and Engineering, Shenzhen University, Shenzhen 518060, China; (J.H.); (J.D.); (C.H.); (X.Z.)
| | - Caiping Huang
- Shenzhen Key Laboratory of Special Functional Materials & Guangdong Research Center for Interfacial Engineering of Functional Materials, College of Materials Science and Engineering, Shenzhen University, Shenzhen 518060, China; (J.H.); (J.D.); (C.H.); (X.Z.)
| | - Xierong Zeng
- Shenzhen Key Laboratory of Special Functional Materials & Guangdong Research Center for Interfacial Engineering of Functional Materials, College of Materials Science and Engineering, Shenzhen University, Shenzhen 518060, China; (J.H.); (J.D.); (C.H.); (X.Z.)
| | - Weiwei Wei
- Shenzhen Key Laboratory of Special Functional Materials & Guangdong Research Center for Interfacial Engineering of Functional Materials, College of Materials Science and Engineering, Shenzhen University, Shenzhen 518060, China; (J.H.); (J.D.); (C.H.); (X.Z.)
| | - Zhezhe Wang
- Fujian Provincial Key Laboratory of Quantum Manipulation and New Energy Materials, College of Physics and Energy, Fujian Normal University, Fuzhou 350117, China;
| | - Peng Lin
- Shenzhen Key Laboratory of Special Functional Materials & Guangdong Research Center for Interfacial Engineering of Functional Materials, College of Materials Science and Engineering, Shenzhen University, Shenzhen 518060, China; (J.H.); (J.D.); (C.H.); (X.Z.)
| |
Collapse
|
35
|
Wang Y, Wu Y, Lei Y. Microneedle-based glucose monitoring: a review from sampling methods to wearable biosensors. Biomater Sci 2023; 11:5727-5757. [PMID: 37431216 DOI: 10.1039/d3bm00409k] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/12/2023]
Abstract
Blood glucose (BG) monitoring is critical for diabetes management. In recent years, microneedle (MN)-based technology has attracted emerging attention in glucose sensing and detection. In this review, we summarized MN-based sampling for glucose collection and glucose analysis in detail. First, different principles of MN-based biofluid extraction were elaborated, including external negative pressure, capillary force, swelling force and iontophoresis, which would guide the shape design and material optimization of MNs. Second, MNs coupled with different analysis approaches, including Raman methods, colorimetry, fluorescence, and electrochemical sensing, were emphasized to exhibit the trend towards highly integrated wearable sensors. Finally, the future development prospects of MN-based devices were discussed.
Collapse
Affiliation(s)
- Yan Wang
- School of Power and Mechanical Engineering & The Institute of Technological Science, Wuhan University, Wuhan 430072, China.
| | - You Wu
- School of Power and Mechanical Engineering & The Institute of Technological Science, Wuhan University, Wuhan 430072, China.
| | - Yifeng Lei
- School of Power and Mechanical Engineering & The Institute of Technological Science, Wuhan University, Wuhan 430072, China.
- Wuhan University Shenzhen Research Institute, Shenzhen 518057, China
| |
Collapse
|
36
|
Li P, Peng Y, Cai J, Bai Y, Li Q, Pang H. Recent Advances in Metal-Organic Frameworks (MOFs) and Their Composites for Non-Enzymatic Electrochemical Glucose Sensors. Bioengineering (Basel) 2023; 10:733. [PMID: 37370664 DOI: 10.3390/bioengineering10060733] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2023] [Revised: 06/07/2023] [Accepted: 06/16/2023] [Indexed: 06/29/2023] Open
Abstract
In recent years, with pressing needs such as diabetes management, the detection of glucose in various substrates has attracted unprecedented interest from researchers in academia and industry. As a relatively new glucose sensor, non-enzymatic target detection has the characteristics of high sensitivity, good stability and simple manufacturing process. However, it is urgent to explore novel materials with low cost, high stability and excellent performance to modify electrodes. Metal-organic frameworks (MOFs) and their composites have the advantages of large surface area, high porosity and high catalytic efficiency, which can be utilized as excellent materials for electrode modification of non-enzymatic electrochemical glucose sensors. However, MOFs and their composites still face various challenges and difficulties that limit their further commercialization. This review introduces the applications and the challenges of MOFs and their composites in non-enzymatic electrochemical glucose sensors. Finally, an outlook on the development of MOFs and their composites is also presented.
Collapse
Affiliation(s)
- Panpan Li
- Guangling College, Yangzhou University, Yangzhou 225009, China
| | - Yi Peng
- School of Chemistry and Chemical Engineering, Yangzhou University, Yangzhou 225009, China
| | - Jinpeng Cai
- School of Chemistry and Chemical Engineering, Yangzhou University, Yangzhou 225009, China
| | - Yang Bai
- School of Pharmacy, Changzhou University, Changzhou 213164, China
- State Key Laboratory of Coordination Chemistry, Nanjing University, Nanjing 210008, China
| | - Qing Li
- Guangling College, Yangzhou University, Yangzhou 225009, China
| | - Huan Pang
- School of Chemistry and Chemical Engineering, Yangzhou University, Yangzhou 225009, China
| |
Collapse
|
37
|
Zhang S, Zhao W, Zeng J, He Z, Wang X, Zhu Z, Hu R, Liu C, Wang Q. Wearable non-invasive glucose sensors based on metallic nanomaterials. Mater Today Bio 2023; 20:100638. [PMID: 37128286 PMCID: PMC10148187 DOI: 10.1016/j.mtbio.2023.100638] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2023] [Revised: 04/01/2023] [Accepted: 04/14/2023] [Indexed: 05/03/2023] Open
Abstract
The development of wearable non-invasive glucose sensors provides a convenient technical means to monitor the glucose concentration of diabetes patients without discomfortability and risk of infection. Apart from enzymes as typical catalytic materials, the active catalytic materials of the glucose sensor are mainly composed of polymers, metals, alloys, metal compounds, and various metals that can undergo catalytic oxidation with glucose. Among them, metallic nanomaterials are the optimal materials applied in the field of wearable non-invasive glucose sensing due to good biocompatibility, large specific surface area, high catalytic activity, and strong adsorption capacity. This review summarizes the metallic nanomaterials used in wearable non-invasive glucose sensors including zero-dimensional (0D), one-dimensional (1D), and two-dimensional (2D) monometallic nanomaterials, bimetallic nanomaterials, metal oxide nanomaterials, etc. Besides, the applications of wearable non-invasive biosensors based on these metallic nanomaterials towards glucose detection are summarized in detail and the development trend of the wearable non-invasive glucose sensors based on metallic nanomaterials is also outlook.
Collapse
Affiliation(s)
- Sheng Zhang
- Ningbo Innovation Center, Zhejiang University, Ningbo, 315100, China
- School of Mechanical Engineering, Zhejiang University, Hangzhou, 310027, China
- NingboTech University, Ningbo, 315100, China
- Faculty of Science and Engineering, University of Nottingham Ningbo China, Ningbo, 315100, China
| | - Wenjie Zhao
- Ningbo Innovation Center, Zhejiang University, Ningbo, 315100, China
- School of Mechanical Engineering, Zhejiang University, Hangzhou, 310027, China
| | - Junyan Zeng
- Ningbo Innovation Center, Zhejiang University, Ningbo, 315100, China
- School of Mechanical Engineering, Zhejiang University, Hangzhou, 310027, China
| | - Zhaotao He
- Ningbo Innovation Center, Zhejiang University, Ningbo, 315100, China
- School of Mechanical Engineering, Zhejiang University, Hangzhou, 310027, China
| | - Xiang Wang
- Faculty of Science and Engineering, University of Nottingham Ningbo China, Ningbo, 315100, China
| | - Zehui Zhu
- Ningbo Innovation Center, Zhejiang University, Ningbo, 315100, China
| | - Runqing Hu
- NingboTech University, Ningbo, 315100, China
| | - Chen Liu
- Ningbo Innovation Center, Zhejiang University, Ningbo, 315100, China
- Faculty of Science and Engineering, University of Nottingham Ningbo China, Ningbo, 315100, China
- Corresponding author. Ningbo Innovation Center, Zhejiang University, Ningbo, 315100, China.
| | - Qianqian Wang
- Ningbo Innovation Center, Zhejiang University, Ningbo, 315100, China
- NingboTech University, Ningbo, 315100, China
- Corresponding author. Ningbo Innovation Center, Zhejiang University, Ningbo, 315100, China.
| |
Collapse
|
38
|
Wang Q, Sun D, Ma X, Huang R, Xu J, Xu X, Cai L, Xu L. Surface enhanced Raman scattering active substrate based on hydrogel microspheres for pretreatment-free detection of glucose in biological samples. Talanta 2023; 260:124657. [PMID: 37187030 DOI: 10.1016/j.talanta.2023.124657] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2023] [Revised: 04/13/2023] [Accepted: 05/08/2023] [Indexed: 05/17/2023]
Abstract
Determining glucose in biological samples is tedious and time-consuming due to sample pretreatment. The sample is usually pretreated to remove lipids, proteins, hemocytes and other sugars that interfere with glucose detection. A surface-enhanced Raman scattering (SERS) active substrate based on hydrogel microspheres has been developed to detect glucose in biological samples. Due to the specific catalytic action of glucose oxidase (GOX), the high selectivity of detection is guaranteed. The hydrogel substrate prepared by microfluidic droplets technology protects the silver nanoparticles from the surrounding environment and improves the stability and reproducibility of the assay. In addition, the hydrogel microspheres have size-adjustable pores that selectively allow small molecules to pass through. The pores block the entry of large molecules, such as impurities, enabling glucose detection through glucose oxidase etching without sample pretreatment. This hydrogel microsphere-SERS platform is highly sensitive and enables reproducible detection of different glucose concentrations in biological samples. The use of SERS to detect glucose provides clinicians with new diagnostic methods for diabetes and a new application opportunity for SERS-based molecular detection techniques.
Collapse
Affiliation(s)
- Qin Wang
- School of Pharmacy, Jiangsu Key Laboratory of Inflammation and Molecular Drug Targets, Nantong University, Nantong, 226001, China; Department of Pharmacy, Affiliated Hospital of Nantong University, Nantong, 226001, China
| | - Dan Sun
- School of Pharmacy, Jiangsu Key Laboratory of Inflammation and Molecular Drug Targets, Nantong University, Nantong, 226001, China
| | - Xiaofei Ma
- Department of Pharmacy, Affiliated Hospital of Nantong University, Nantong, 226001, China
| | - Rongrong Huang
- Department of Pharmacy, Affiliated Hospital of Nantong University, Nantong, 226001, China
| | - Jinqiu Xu
- Department of Pharmacy, Affiliated Hospital of Nantong University, Nantong, 226001, China
| | - Xin Xu
- Department of Pharmacy, Affiliated Hospital of Nantong University, Nantong, 226001, China.
| | - Liangliang Cai
- Department of Pharmacy, Affiliated Hospital of Nantong University, Nantong, 226001, China.
| | - Lixing Xu
- School of Pharmacy, Jiangsu Key Laboratory of Inflammation and Molecular Drug Targets, Nantong University, Nantong, 226001, China.
| |
Collapse
|
39
|
Dong Q, Ling C, Zhao S, Tang X, Zhang Y, Xing Y, Yu H, Huang K, Zou Z, Xiong X. One-step rapid synthesis of Ni 0.5Co 0.5-CPO-27 nanorod array with oxygen vacancies based on DBD microplasma: As an effective non-enzymatic glucose sensor for beverage and human serum. Food Chem 2023; 407:135144. [PMID: 36493474 DOI: 10.1016/j.foodchem.2022.135144] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2022] [Revised: 11/26/2022] [Accepted: 11/30/2022] [Indexed: 12/03/2022]
Abstract
The rational design of high-efficiency catalysts for non-enzymatic glucose sensing is extremely important for the timely and effective monitoring of glucose content in beverages and human blood. A 3D bimetallic organic framework (Coordination Polymer of Oslo, CPO) nanorod array with oxygen vacancies was green fabricated on carbon cloth (Ni0.5Co0.5-CPO-27 NRA/CC) using dielectric barrier discharge (DBD) microplasma for the first time. Density functional theory (DFT) calculations demonstrated that the oxygen vacancy of Ni0.5Co0.5-CPO-27 can be effectively induced under DBD microplasma conditions. Based on the 3D nanorod arrays with rich oxygen vacancies and bimetallic synergistic effects, as a non-enzyme glucose sensor, the Ni0.5Co0.5-CPO-27 electrode exhibited a sensitivity of 8499.5 μA L/mmol cm-2 and 3239.2 μA L/mmol cm-2 and a limit of detection (LOD) of 0.16 μmol/L (S/N = 3). It has been successfully applied to the determination of glucose levels in real samples such as cola, green tea and human serum.
Collapse
Affiliation(s)
- Qiaoyan Dong
- College of Chemistry and Materials Science, Sichuan Normal University, Chengdu, Sichuan 610068, China
| | - Chengshuang Ling
- College of Chemistry and Materials Science, Sichuan Normal University, Chengdu, Sichuan 610068, China
| | - Shan Zhao
- College of Chemistry and Materials Science, Sichuan Normal University, Chengdu, Sichuan 610068, China
| | - Xin Tang
- College of Chemistry and Materials Science, Sichuan Normal University, Chengdu, Sichuan 610068, China
| | - Yu Zhang
- College of Chemistry and Materials Science, Sichuan Normal University, Chengdu, Sichuan 610068, China
| | - Yun Xing
- College of Chemistry and Materials Science, Sichuan Normal University, Chengdu, Sichuan 610068, China
| | - Huimin Yu
- College of Chemistry and Materials Science, Sichuan Normal University, Chengdu, Sichuan 610068, China
| | - Ke Huang
- College of Chemistry and Materials Science, Sichuan Normal University, Chengdu, Sichuan 610068, China
| | - Zhirong Zou
- College of Chemistry and Materials Science, Sichuan Normal University, Chengdu, Sichuan 610068, China.
| | - Xiaoli Xiong
- College of Chemistry and Materials Science, Sichuan Normal University, Chengdu, Sichuan 610068, China.
| |
Collapse
|
40
|
Xia HQ, Qiu D, Chen W, Mao G, Zeng J. In situ formed and fully integrated laser-induced graphene electrochemical chips for rapid and simultaneous determination of bioflavonoids in citrus fruits. Microchem J 2023. [DOI: 10.1016/j.microc.2023.108474] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
|
41
|
Yang Y, Ji W, Yin Y, Wang N, Wu W, Zhang W, Pei S, Liu T, Tao C, Zheng B, Wu Q, Li L. Catalytic Modification of Porous Two-Dimensional Ni-MOFs on Portable Electrochemical Paper-Based Sensors for Glucose and Hydrogen Peroxide Detection. BIOSENSORS 2023; 13:bios13050508. [PMID: 37232869 DOI: 10.3390/bios13050508] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/11/2023] [Revised: 04/17/2023] [Accepted: 04/27/2023] [Indexed: 05/27/2023]
Abstract
Rapid and accurate detection of changes in glucose (Glu) and hydrogen peroxide (H2O2) concentrations is essential for the predictive diagnosis of diseases. Electrochemical biosensors exhibiting high sensitivity, reliable selectivity, and rapid response provide an advantageous and promising solution. A porous two-dimensional conductive metal-organic framework (cMOF), Ni-HHTP (HHTP = 2,3,6,7,10,11-hexahydroxytriphenylene), was prepared by using a one-pot method. Subsequently, it was employed to construct enzyme-free paper-based electrochemical sensors by applying mass-producing screen-printing and inkjet-printing techniques. These sensors effectively determined Glu and H2O2 concentrations, achieving low limits of detection of 1.30 μM and 2.13 μM, and high sensitivities of 5573.21 μA μM-1 cm-2 and 179.85 μA μM-1 cm-2, respectively. More importantly, the Ni-HHTP-based electrochemical sensors showed an ability to analyze real biological samples by successfully distinguishing human serum from artificial sweat samples. This work provides a new perspective for the use of cMOFs in the field of enzyme-free electrochemical sensing, highlighting their potential for future applications in the design and development of new multifunctional and high-performance flexible electronic sensors.
Collapse
Affiliation(s)
- Ya Yang
- Key Laboratory of Flexible Electronics (KLOFE), Institute of Advanced Materials (IAM), Nanjing Tech University (NanjingTech), Nanjing 211800, China
| | - Wenhui Ji
- Key Laboratory of Flexible Electronics (KLOFE), Institute of Advanced Materials (IAM), Nanjing Tech University (NanjingTech), Nanjing 211800, China
| | - Yutao Yin
- Key Laboratory of Flexible Electronics (KLOFE), Institute of Advanced Materials (IAM), Nanjing Tech University (NanjingTech), Nanjing 211800, China
| | - Nanxiang Wang
- Key Laboratory of Flexible Electronics (KLOFE), Institute of Advanced Materials (IAM), Nanjing Tech University (NanjingTech), Nanjing 211800, China
| | - Wanxia Wu
- Key Laboratory of Flexible Electronics (KLOFE), Institute of Advanced Materials (IAM), Nanjing Tech University (NanjingTech), Nanjing 211800, China
| | - Wei Zhang
- Key Laboratory of Flexible Electronics (KLOFE), Institute of Advanced Materials (IAM), Nanjing Tech University (NanjingTech), Nanjing 211800, China
| | - Siying Pei
- Key Laboratory of Flexible Electronics (KLOFE), Institute of Advanced Materials (IAM), Nanjing Tech University (NanjingTech), Nanjing 211800, China
| | - Tianwei Liu
- Key Laboratory of Flexible Electronics (KLOFE), Institute of Advanced Materials (IAM), Nanjing Tech University (NanjingTech), Nanjing 211800, China
| | - Chao Tao
- The First Affiliated Hospital of Nanjing Medical University, Nanjing 210029, China
| | - Bing Zheng
- Key Laboratory of Flexible Electronics (KLOFE), Institute of Advanced Materials (IAM), Nanjing Tech University (NanjingTech), Nanjing 211800, China
| | - Qiong Wu
- Key Laboratory of Flexible Electronics (KLOFE), Institute of Advanced Materials (IAM), Nanjing Tech University (NanjingTech), Nanjing 211800, China
| | - Lin Li
- Key Laboratory of Flexible Electronics (KLOFE), Institute of Advanced Materials (IAM), Nanjing Tech University (NanjingTech), Nanjing 211800, China
- The Institute of Flexible Electronics (IFE, Future Technologies), Xiamen University, Xiamen 361005, China
| |
Collapse
|
42
|
Chi L, Zhang C, Wu X, Qian X, Sun H, He M, Guo C. Research Progress on Biomimetic Nanomaterials for Electrochemical Glucose Sensors. Biomimetics (Basel) 2023; 8:biomimetics8020167. [PMID: 37092419 PMCID: PMC10123724 DOI: 10.3390/biomimetics8020167] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2023] [Revised: 04/16/2023] [Accepted: 04/17/2023] [Indexed: 04/25/2023] Open
Abstract
Diabetes has become a chronic disease that necessitates timely and accurate detection. Among various detection methods, electrochemical glucose sensors have attracted much attention because of low cost, real-time detection, and simple and easy operation. Nonenzymatic biomimetic nanomaterials are the vital part in electrochemical glucose sensors. This review article summarizes the methods to enhance the glucose sensing performance of noble metal, transition metal oxides, and carbon-based materials and introduces biomimetic nanomaterials used in noninvasive glucose detection in sweat, tear, urine, and saliva. Based on these, this review provides the foundation for noninvasive determination of trace glucose for diabetic patients in the future.
Collapse
Affiliation(s)
- Lili Chi
- School of Materials Science and Engineering, Suzhou University of Science and Technology, Suzhou 215009, China
| | - Chunmei Zhang
- School of Materials Science and Engineering, Suzhou University of Science and Technology, Suzhou 215009, China
| | - Xuanyu Wu
- School of Materials Science and Engineering, Suzhou University of Science and Technology, Suzhou 215009, China
- School of Environmental Science and Engineering, Suzhou University of Science and Technology, Suzhou 215009, China
| | - Xianghao Qian
- School of Materials Science and Engineering, Suzhou University of Science and Technology, Suzhou 215009, China
| | - Hao Sun
- School of Materials Science and Engineering, Suzhou University of Science and Technology, Suzhou 215009, China
| | - Mengru He
- School of Materials Science and Engineering, Suzhou University of Science and Technology, Suzhou 215009, China
| | - Chunxian Guo
- School of Materials Science and Engineering, Suzhou University of Science and Technology, Suzhou 215009, China
| |
Collapse
|
43
|
An enzyme-free Ti 3C 2/Ni/Sm-LDH-based screen-printed-electrode for real-time sweat detection of glucose. Anal Chim Acta 2023; 1250:340981. [PMID: 36898808 DOI: 10.1016/j.aca.2023.340981] [Citation(s) in RCA: 13] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2022] [Revised: 01/30/2023] [Accepted: 02/14/2023] [Indexed: 02/18/2023]
Abstract
Here, we report the fabrication of an enzyme-free glucose sensor benefiting from nickel-samarium nanoparticles-decorated MXene layered double hydroxide (MXene/Ni/Sm-LDH). The electrochemical response of the MXene/Ni/Sm-LDH to glucose was studied via cyclic voltammetry (CV). The fabricated electrode has high electrocatalytic activity for glucose oxidation. The voltametric response of the MXene/Ni/Sm-LDH electrode to glucose was investigated by differential pulse voltammetry (DPV) that demonstrated an extended linear range of from 0.001 to 0.1 mM and 0.25-7.5 mM with a detection limit down to 0.24 μM (S/N = 3) and a sensitivity at 1673.54 μA mM-1 cm-2 1519.09 μA mM-1 cm-2 in concentrations of 0.01 mM and 1 mM respectively as well as good repeatability, high stability and applicability for the real sample analysis. Moreover, the as-fabricated sensor was applied to glucose detection in human sweat and showed promising results.
Collapse
|
44
|
Fan H, Le Boeuf W, Maheshwari V. Au-Pt-Ni nanochains as dopamine catalysts: role of elements and their spatial distribution. NANOSCALE ADVANCES 2023; 5:2244-2250. [PMID: 37056628 PMCID: PMC10089120 DOI: 10.1039/d2na00932c] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/19/2022] [Accepted: 03/06/2023] [Indexed: 06/19/2023]
Abstract
Multi-element materials can improve biosensing ability as each element can catalyze different steps in a reaction pathway. By combining Pt and Ni on self-assembled 1D gold nanochains and controlling their spatial distribution, a detailed understanding of each element's role in dopamine oxidation is developed. In addition, the developed synthesis process provides a simple way to fabricate multi-element composites for electrocatalytic applications based on electrical double-layer formation on the surface of charged nanoparticles. The performance parameters of the catalyst, such as its sensitivity, limit of detection, and range of operation for dopamine sensing, are optimized by changing the relative ratios of Pt : Ni and the morphology of the Pt and Ni domains, using the developed understanding. The morphology of the domains also affects the oxidation state of Ni, which is crucial to the performance of the electrocatalyst.
Collapse
Affiliation(s)
- Hua Fan
- Department of Chemistry, Waterloo Institute for Nanotechnology 200 University Ave. West Waterloo N2L 3G1 ON Canada
| | - William Le Boeuf
- Department of Chemistry, Waterloo Institute for Nanotechnology 200 University Ave. West Waterloo N2L 3G1 ON Canada
| | - Vivek Maheshwari
- Department of Chemistry, Waterloo Institute for Nanotechnology 200 University Ave. West Waterloo N2L 3G1 ON Canada
| |
Collapse
|
45
|
Liu M, Gao T, Li H, Xie B, Hu C, Guo Y, Xiao D. Preparation of amorphous Ni/Co bimetallic nanoparticles to enhance the electrochemical sensing of glucose. Microchem J 2023. [DOI: 10.1016/j.microc.2023.108731] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/09/2023]
|
46
|
Mandal SC, Chakrabarti J. Surface specific adsorption of glucose to ZnO. Phys Chem Chem Phys 2023; 25:7805-7814. [PMID: 36857657 DOI: 10.1039/d2cp05749b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/17/2023]
Abstract
ZnO is bio-safe and hence, may be a potential candidate for direct use as a glucose sensor. This requires an understanding of the interaction of glucose with four common surfaces, (101̄0), (112̄0), (0001) and (0001̄) of ZnO. We carry out molecular dynamics (MD) simulations enhanced by umbrella sampling of a glucose molecule in a solvent over a hydrated ZnO slab. The slab is obtained by quantum mechanical optimization. We observe that hydration layers formed above the surfaces affect the approach of glucose to the surfaces. Potential of mean force (PMF) calculations show that the (101̄0) surface shows the strongest adsorption of adsorption free energy -6.81 kJ mol-1 towards glucose. Thus, we offer a theoretical understanding on the interactions at the nano-bio junction of glucose and ZnO surfaces. Our study suggests that the (101̄0) surface may be used to fabricate a direct glucose sensor.
Collapse
Affiliation(s)
- Sasthi Charan Mandal
- Department of Physics of Complex Systems, S. N. Bose National Centre for Basic Sciences, Block JD, Sector III, Salt Lake, Kolkata 700106, India.
| | - Jaydeb Chakrabarti
- Department of Physics of Complex Systems, S. N. Bose National Centre for Basic Sciences, Block JD, Sector III, Salt Lake, Kolkata 700106, India.
| |
Collapse
|
47
|
Karim R, Saha P, Akter R, Falguni R, Shital RA, Awal A, Al Mamun M, Ahammad AJS. Simultaneous Determination of Ranitidine and Metronidazole at Low Potential Using an Acid‐Activated Glassy Carbon Electrode. ChemistrySelect 2023. [DOI: 10.1002/slct.202204174] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/05/2023]
Affiliation(s)
- Rejwana Karim
- Department of Chemistry Jagannath University Dhaka 1100 Bangladesh
| | - Protity Saha
- Department of Chemistry Jagannath University Dhaka 1100 Bangladesh
| | - Riva Akter
- Department of Chemistry Jagannath University Dhaka 1100 Bangladesh
| | - Rokaiya Falguni
- Department of Chemistry Jagannath University Dhaka 1100 Bangladesh
| | | | - Abdul Awal
- Department of Chemistry Jagannath University Dhaka 1100 Bangladesh
| | | | | |
Collapse
|
48
|
Kumano M, Sugiyama K, Sato F, Komatsu S, Watanabe K, Ono T, Yoshida K, Sasano Y, Iwabuchi Y, Fujimura T, Kashiwagi Y, Sato K. Electrochemical reactions of highly active nitroxyl radicals with thiol compounds. ANAL SCI 2023; 39:369-374. [PMID: 36576651 DOI: 10.1007/s44211-022-00246-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2022] [Accepted: 12/13/2022] [Indexed: 12/29/2022]
Abstract
Nitroxyl radicals are known to electrochemically oxidize thiols as well as alcohols and amines. In this study, a preliminary investigation of the electrochemical reaction of thiols with 9-azabicyclo[3.3.1]nonane N-oxyl (ABNO), 2-azaadamantane N-oxyl (AZADO), and nortropine N-oxyl (NNO), which are highly active due to their bicyclo structures, for use in electrochemical analysis was performed and the results were compared with those for a typical nitroxyl radical compound, 2,2,6,6-tetramethylpiperidine N-oxyl (TEMPO). Mercaptopropane sulfonic acid (MPS) was used as a model compound to investigate the electrochemical response in aqueous solution. In addition, electrochemical detection of glutathione, a biological thiol molecule, was performed.
Collapse
Affiliation(s)
- Masayuki Kumano
- Faculty of Pharmaceutical Science, Tohoku Medical and Pharmaceutical University, 4-4-1 Komatsushima, Aoba, Sendai, Miyagi, 981-8558, Japan
| | - Kyoko Sugiyama
- Faculty of Pharmaceutical Science, Tohoku Medical and Pharmaceutical University, 4-4-1 Komatsushima, Aoba, Sendai, Miyagi, 981-8558, Japan
| | - Fumiya Sato
- Faculty of Pharmaceutical Science, Tohoku Medical and Pharmaceutical University, 4-4-1 Komatsushima, Aoba, Sendai, Miyagi, 981-8558, Japan
| | - Sachiko Komatsu
- Faculty of Pharmaceutical Science, Tohoku Medical and Pharmaceutical University, 4-4-1 Komatsushima, Aoba, Sendai, Miyagi, 981-8558, Japan
| | - Kazuhiro Watanabe
- Faculty of Pharmaceutical Science, Tohoku Medical and Pharmaceutical University, 4-4-1 Komatsushima, Aoba, Sendai, Miyagi, 981-8558, Japan
| | - Tetsuya Ono
- School of Pharmaceutical Sciences, Ohu University, 31-1 Misumido, Tomita-Machi, Koriyama, Fukushima, 963-8611, Japan
| | - Kentaro Yoshida
- School of Pharmaceutical Sciences, Ohu University, 31-1 Misumido, Tomita-Machi, Koriyama, Fukushima, 963-8611, Japan
| | - Yusuke Sasano
- Graduate School of Pharmaceutical Sciences, Tohoku University, 6-3 Aoba, Aramaki, Aoba-ku, Sendai, 980-8578, Japan
| | - Yoshiharu Iwabuchi
- Graduate School of Pharmaceutical Sciences, Tohoku University, 6-3 Aoba, Aramaki, Aoba-ku, Sendai, 980-8578, Japan
| | - Tsutomu Fujimura
- Faculty of Pharmaceutical Science, Tohoku Medical and Pharmaceutical University, 4-4-1 Komatsushima, Aoba, Sendai, Miyagi, 981-8558, Japan
| | - Yoshitomo Kashiwagi
- School of Pharmaceutical Sciences, Ohu University, 31-1 Misumido, Tomita-Machi, Koriyama, Fukushima, 963-8611, Japan.
| | - Katsuhiko Sato
- Faculty of Pharmaceutical Science, Tohoku Medical and Pharmaceutical University, 4-4-1 Komatsushima, Aoba, Sendai, Miyagi, 981-8558, Japan.
| |
Collapse
|
49
|
Wu CW, Chiang MH, Lee CL. Pd@Au Core-Shell Octahedral, Truncated Octahedral, and Cubic Nanocrystals as Nonenzymatic Glucose Sensors for Drinks. Microchem J 2023. [DOI: 10.1016/j.microc.2023.108697] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/30/2023]
|
50
|
Wu W, Li J. Recent Progress on Nanozymes in Electrochemical Sensing. J Electroanal Chem (Lausanne) 2023. [DOI: 10.1016/j.jelechem.2023.117391] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/29/2023]
|