1
|
Nasir Ahamed NN, Mendiola-Escobedo CA, Perez-Gonzalez VH, Lapizco-Encinas BH. Manipulating the insulating post arrangement in DC-biased AC-iEK devices to improve microparticle separations. Analyst 2024; 149:2469-2479. [PMID: 38516870 DOI: 10.1039/d3an02160b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/23/2024]
Abstract
There is a growing interest in the advancement of microscale electrokinetic (EK) systems for biomedical and clinical applications, as these systems offer attractive characteristics such as portability, robustness, low sample requirements and short response time. The present work is focused on manipulating the characteristics of the insulating post arrangement in insulator-based EK (iEK) systems for separating a binary mixture of spherical microparticles with same diameter (5.1 μm), same shape, made from the same substrate material and only differing in their zeta potential by ∼14 mV. This study presents a combination of mathematical modeling and experimental separations performed by applying a low-frequency alternating current (AC) voltage in iEK systems with 12 distinct post arrangements. These iEK devices were used to systematically study the effect of three spatial characteristics of the insulating post array on particle separations: the horizontal separation and the vertical separation between posts, and introducing an offset to the posts arrangement. Through normalization of the spatial separation between the insulating posts with respect to particle diameter, guidelines to improve separation resolution for different particle mixtures possessing similar characteristics were successfully identified. The results indicated that by carefully designing the spatial arrangement of the post array, separation resolution values in the range of 1.4-2.8 can be obtained, illustrating the importance and effect of the arrangement of insulating posts on improving particle separations. This study demonstrates that iEK devices, with effectively designed spatial arrangement of the insulating post arrays, have the capabilities to perform discriminatory separations of microparticles of similar characteristics.
Collapse
Affiliation(s)
- Nuzhet Nihaar Nasir Ahamed
- Microscale Bioseparations Laboratory and Biomedical Engineering Department, Rochester Institute of Technology, 160 Lomb Memorial Drive, Rochester, New York, 14623, USA.
| | | | - Victor H Perez-Gonzalez
- School of Engineering and Sciences, Tecnologico de Monterrey, Monterrey, Nuevo Leon 64849, Mexico.
| | - Blanca H Lapizco-Encinas
- Microscale Bioseparations Laboratory and Biomedical Engineering Department, Rochester Institute of Technology, 160 Lomb Memorial Drive, Rochester, New York, 14623, USA.
| |
Collapse
|
2
|
Vaghef-Koodehi A, Cyr P, Lapizco-Encinas BH. Improving device design in insulator-based electrokinetic tertiary separations. J Chromatogr A 2024; 1722:464853. [PMID: 38579611 DOI: 10.1016/j.chroma.2024.464853] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2024] [Revised: 03/20/2024] [Accepted: 03/26/2024] [Indexed: 04/07/2024]
Abstract
This study presents a methodology for designing effective insulator-based electrokinetic (iEK) systems for separating tertiary microparticle samples, which can be extended to more complex samples. First, 144 distinct iEK microchannel designs were built considering different shapes and arrangements of the insulating posts. Second, a mathematical model was developed with COMSOL software to predict the retention time of each particle type in the microchannel, this allowed identifying the best channel designs for two distinct types of separations: charge-based and sized-based. Third, the experimental charge-based and size-based separations of the tertiary microparticle mixtures were performed employing the improved designs identified with COMSOL modeling. The experimental results demonstrated successful separation in terms of separation resolution and good agreement with COMSOL predictions. The findings from this study show that the proposed method for device design, which combines mathematical modeling with varying post shape and post arrangement is an effective approach for identifying iEK systems capable of separating complex microparticle samples.
Collapse
Affiliation(s)
- Alaleh Vaghef-Koodehi
- Microscale Bioseparations Laboratory and Biomedical Engineering Department, Rochester Institute of Technology, 160 Lomb Memorial Drive, Rochester, NY 14623, United States
| | - Patricia Cyr
- Department of Industrial and Systems Engineering, Rochester Institute of Technology, 160 Lomb Memorial Drive, Rochester, NY 14623, United States
| | - Blanca H Lapizco-Encinas
- Microscale Bioseparations Laboratory and Biomedical Engineering Department, Rochester Institute of Technology, 160 Lomb Memorial Drive, Rochester, NY 14623, United States.
| |
Collapse
|
3
|
Morofuji R, Kudo K, Honda T, Kinugasa S, Matsuo T, Okabe K. Enhancing Corneal Drug Penetration Using Penetratin for Ophthalmic Suspensions. Biol Pharm Bull 2024; 47:1033-1042. [PMID: 38797668 DOI: 10.1248/bpb.b24-00077] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/29/2024]
Abstract
Eye drops, including solutions and suspensions, are essential dosage forms to treat ophthalmic diseases, with poorly water-soluble drugs typically formulated as ophthalmic suspensions. In addition to low bioavailability, suspensions exhibit limited efficacy, safety, and usability due to the presence of drug particles. Improving bioavailability can reduce the drug concentrations and the risk of problems associated with suspended drug particles. However, practical penetration enhancers capable of improving bioavailability remain elusive. Herein, we focused on penetratin (PNT), a cell-penetrating peptide (CPP) that promotes active cellular transport related to macromolecule uptake, such as micropinocytosis. According to the in vitro corneal uptake study using a reconstructed human corneal epithelial tissue model, LabCyte CORNEA-MODEL24, PNT enhanced the uptake of Fluoresbrite® YG carboxylate polystyrene microspheres without covalent binding. In an ex vivo porcine eye model, the addition of 10 µM PNT to rebamipide ophthalmic suspension markedly improved the corneal uptake of rebamipide; however, the addition of 100 µM PNT was ineffective due to potentially increased particle size by aggregation. This article provides basic information on the application of PNT as a penetration enhancer in ophthalmic suspensions, including the in vitro and ex vivo studies mentioned above, as well as the 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) cytotoxicity assay and storage stability at different pH values.
Collapse
Affiliation(s)
- Ryo Morofuji
- Division of Materials Science, Nara Institute of Science and Technology
- Pharmaceutical Development Division, Nara Research & Development Center, Santen Pharmaceutical Co., Ltd
| | - Kazuhiro Kudo
- Division of Materials Science, Nara Institute of Science and Technology
- Pharmaceutical Development Division, Nara Research & Development Center, Santen Pharmaceutical Co., Ltd
| | - Takahiro Honda
- Pharmaceutical Development Division, Nara Research & Development Center, Santen Pharmaceutical Co., Ltd
| | - Shino Kinugasa
- Division of Materials Science, Nara Institute of Science and Technology
| | - Takamasa Matsuo
- Division of Materials Science, Nara Institute of Science and Technology
| | - Komei Okabe
- Division of Materials Science, Nara Institute of Science and Technology
- Pharmaceutical Development Division, Nara Research & Development Center, Santen Pharmaceutical Co., Ltd
| |
Collapse
|
4
|
Calero V, Fernández-Mateo R, Morgan H, García-Sánchez P, Ramos A. Low-frequency electrokinetics in a periodic pillar array for particle separation. J Chromatogr A 2023; 1706:464240. [PMID: 37544238 DOI: 10.1016/j.chroma.2023.464240] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2023] [Revised: 07/18/2023] [Accepted: 07/23/2023] [Indexed: 08/08/2023]
Abstract
Deterministic Lateral Displacement (DLD) exploits periodic arrays of pillars inside microfluidic channels for high-precision sorting of micro- and nano-particles. Previously we demonstrated how DLD separation can be significantly improved by the addition of AC electrokinetic forces, increasing the tunability of the technique and expanding the range of applications. At high frequencies of the electric field (>1 kHz) the behaviour of such systems is dominated by Dielectrophoresis (DEP), whereas at low frequencies the particle behaviour is much richer and more complex. In this article, we present a detailed numerical analysis of the mechanisms governing particle motion in a DLD micropillar array in the presence of a low-frequency AC electric field. We show how a combination of Electrophoresis (EP) and Concentration-Polarisation Electroosmosis (CPEO) driven wall-particle repulsion account for the observed experimental behaviour of particles, and demonstrate how this complete model can predict conditions that lead to electrically induced deviation of particles much smaller than the critical size of the DLD array.
Collapse
Affiliation(s)
- Víctor Calero
- Depto. Electrónica y Electromagnetismo, Facultad de Física, Universidad de Sevilla, Avda. Reina Mercedes s/n, 41012, Sevilla, Spain; International Iberian Nanotechnology Laboratory (INL), Braga 4715-330, Portugal
| | - Raúl Fernández-Mateo
- School of Electronics and Computer Science, University of Southampton, Southampton SO17 1BJ, United Kingdom
| | - Hywel Morgan
- School of Electronics and Computer Science, University of Southampton, Southampton SO17 1BJ, United Kingdom
| | - Pablo García-Sánchez
- Depto. Electrónica y Electromagnetismo, Facultad de Física, Universidad de Sevilla, Avda. Reina Mercedes s/n, 41012, Sevilla, Spain.
| | - Antonio Ramos
- Depto. Electrónica y Electromagnetismo, Facultad de Física, Universidad de Sevilla, Avda. Reina Mercedes s/n, 41012, Sevilla, Spain
| |
Collapse
|
5
|
Fernández-Mateo R, Calero V, Morgan H, García-Sánchez P, Ramos A. Insulating traveling-wave electrophoresis. Phys Rev E 2023; 108:015104. [PMID: 37583165 DOI: 10.1103/physreve.108.015104] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2023] [Accepted: 06/29/2023] [Indexed: 08/17/2023]
Abstract
Traveling-wave electrophoresis (TWE) is a method for transporting charged colloidal particles used in many microfluidic techniques for particle manipulation and fractionation. This method exploits the traveling-wave components of the electric field generated by an array of electrodes subjected to ac voltages with a phase delay between neighboring electrodes. In this article, we propose an alternative way of generating traveling-wave electric fields in microchannels. We apply a rotating electric field around a cylindrical insulating micropillar and the resulting traveling-wave modes induce particle drift around the cylinder. We term this phenomenon insulating traveling-wave electrophoresis (i-TWE) to distinguish it from standard TWE performed with arrays of microelectrodes. We characterized the particle drift experimentally and show a quantitative comparison of the particle velocity with theoretical predictions. Excellent agreement is found when the influence of electro-osmosis on the channel walls is also considered.
Collapse
Affiliation(s)
- Raúl Fernández-Mateo
- School of Electronics and Computer Science, University of Southampton, Southampton SO17 1BJ, United Kingdom
| | - Víctor Calero
- Departamento de Electrónica y Electromagnetismo, Facultad de Física, Universidad de Sevilla, Avda. Reina Mercedes s/n, 41012 Sevilla, Spain
| | - Hywel Morgan
- School of Electronics and Computer Science, University of Southampton, Southampton SO17 1BJ, United Kingdom
| | - Pablo García-Sánchez
- Departamento de Electrónica y Electromagnetismo, Facultad de Física, Universidad de Sevilla, Avda. Reina Mercedes s/n, 41012 Sevilla, Spain
| | - Antonio Ramos
- Departamento de Electrónica y Electromagnetismo, Facultad de Física, Universidad de Sevilla, Avda. Reina Mercedes s/n, 41012 Sevilla, Spain
| |
Collapse
|
6
|
Mohammadi R, Afsaneh H, Rezaei B, Moghimi Zand M. On-chip dielectrophoretic device for cancer cell manipulation: A numerical and artificial neural network study. BIOMICROFLUIDICS 2023; 17:024102. [PMID: 36896355 PMCID: PMC9991445 DOI: 10.1063/5.0131806] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/24/2022] [Accepted: 02/03/2023] [Indexed: 06/18/2023]
Abstract
Breast cancer, as one of the most frequent types of cancer in women, imposes large financial and human losses annually. MCF-7, a well-known cell line isolated from the breast tissue of cancer patients, is usually used in breast cancer research. Microfluidics is a newly established technique that provides many benefits, such as sample volume reduction, high-resolution operations, and multiple parallel analyses for various cell studies. This numerical study presents a novel microfluidic chip for the separation of MCF-7 cells from other blood cells, considering the effect of dielectrophoretic force. An artificial neural network, a novel tool for pattern recognition and data prediction, is implemented in this research. To prevent hyperthermia in cells, the temperature should not exceed 35 °C. In the first part, the effect of flow rate and applied voltage on the separation time, focusing efficiency, and maximum temperature of the field is investigated. The results denote that the separation time is affected by both the input parameters inversely, whereas the two remaining parameters increase with the input voltage and decrease with the sheath flow rate. A maximum focusing efficiency of 81% is achieved with a purity of 100% for a flow rate of 0.2 μ L / min and a voltage of 3.1 V . In the second part, an artificial neural network model is established to predict the maximum temperature inside the separation microchannel with a relative error of less than 3% for a wide range of input parameters. Therefore, the suggested label-free lab-on-a-chip device separates the target cells with high-throughput and low voltages.
Collapse
Affiliation(s)
- Rasool Mohammadi
- School of Mechanical Engineering, College of Engineering, University of Tehran, Tehran 11155-463, Iran
| | - Hadi Afsaneh
- Department of Chemical and Materials Engineering, University of Alberta, Edmonton, Alberta T6G 1H9, Canada
| | - Behnam Rezaei
- Small Medical Devices, BioMEMS, and LoC Lab, School of Mechanical Engineering, College of Engineering, University of Tehran, Tehran 11155-463, Iran
| | - Mahdi Moghimi Zand
- Small Medical Devices, BioMEMS, and LoC Lab, School of Mechanical Engineering, College of Engineering, University of Tehran, Tehran 11155-463, Iran
| |
Collapse
|
7
|
Goss DM, Vasilescu SA, Sacks G, Gardner DK, Warkiani ME. Microfluidics facilitating the use of small extracellular vesicles in innovative approaches to male infertility. Nat Rev Urol 2023; 20:66-95. [PMID: 36348030 DOI: 10.1038/s41585-022-00660-8] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/22/2022] [Indexed: 11/09/2022]
Abstract
Sperm are transcriptionally and translationally quiescent and, therefore, rely on the seminal plasma microenvironment for function, survival and fertilization of the oocyte in the oviduct. The male reproductive system influences sperm function via the binding and fusion of secreted epididymal (epididymosomes) and prostatic (prostasomes) small extracellular vesicles (S-EVs) that facilitate the transfer of proteins, lipids and nucleic acids to sperm. Seminal plasma S-EVs have important roles in sperm maturation, immune and oxidative stress protection, capacitation, fertilization and endometrial implantation and receptivity. Supplementing asthenozoospermic samples with normospermic-derived S-EVs can improve sperm motility and S-EV microRNAs can be used to predict non-obstructive azoospermia. Thus, S-EV influence on sperm physiology might have both therapeutic and diagnostic potential; however, the isolation of pure populations of S-EVs from bodily fluids with current conventional methods presents a substantial hurdle. Many conventional techniques lack accuracy, effectiveness, and practicality; yet microfluidic technology has the potential to simplify and improve S-EV isolation and detection.
Collapse
Affiliation(s)
- Dale M Goss
- School of Biomedical Engineering, University of Technology Sydney, Sydney, NSW, Australia
- IVF Australia, Sydney, NSW, Australia
| | - Steven A Vasilescu
- School of Biomedical Engineering, University of Technology Sydney, Sydney, NSW, Australia
- NeoGenix Biosciences pty ltd, Sydney, NSW, Australia
| | - Gavin Sacks
- IVF Australia, Sydney, NSW, Australia
- University of New South Wales, Sydney, NSW, Australia
| | - David K Gardner
- Melbourne IVF, East Melbourne, VIC, Australia.
- School of BioSciences, University of Melbourne, Melbourne, VIC, Australia.
| | - Majid E Warkiani
- School of Biomedical Engineering, University of Technology Sydney, Sydney, NSW, Australia.
| |
Collapse
|
8
|
Flores-Mena JE, García-Sánchez P, Ramos A. Scattering of Metal Colloids by a Circular Post under Electric Fields. MICROMACHINES 2022; 14:23. [PMID: 36677083 PMCID: PMC9866174 DOI: 10.3390/mi14010023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/22/2022] [Revised: 12/12/2022] [Accepted: 12/17/2022] [Indexed: 06/17/2023]
Abstract
We consider the scattering of metal colloids in aqueous solutions by an insulating circular post under the action of an AC electric field. We analyze the effects on the particle of several forces of electrical origin: the repulsion between the induced dipole of the particle and its image dipole in the post, the hydrodynamic interaction with the post due to the induced-charge electroosmotic (ICEO) flow around the particle, and the dielectrophoresis arising from the distortion of the applied electric field around the post. The relative influence of these forces is discussed as a function of frequency of the AC field, particle size and distance to the post. We perform numerical simulations of the scattering of the metal colloid by the insulating circular post flowing in a microchannel and subjected to alternating current electric fields. Our simulation results show that the maximum particle deviation is found for an applied electric field parallel to the flow direction. The deviation is also greater at low electric field frequencies, corresponding to the regime in which the ICEO's interaction with the post is predominant over other mechanisms.
Collapse
Affiliation(s)
- José Eladio Flores-Mena
- Facultad de Ciencias de la Electrónica, Benemérita Universidad Autónoma de Puebla, Av. San Claudio y 18 Sur, San Manuel, CU. FCE2, Puebla 72570, Mexico
| | - Pablo García-Sánchez
- Departamento Electrónica y Electromagnetismo, Facultad de Física, Universidad de Sevilla, Avda. Reina Mercedes s/n, 41012 Sevilla, Spain
| | - Antonio Ramos
- Departamento Electrónica y Electromagnetismo, Facultad de Física, Universidad de Sevilla, Avda. Reina Mercedes s/n, 41012 Sevilla, Spain
| |
Collapse
|
9
|
Gillams RJ, Calero V, Fernandez-Mateo R, Morgan H. Electrokinetic deterministic lateral displacement for fractionation of vesicles and nano-particles. LAB ON A CHIP 2022; 22:3869-3876. [PMID: 36065949 DOI: 10.1039/d2lc00583b] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
We describe fractionation of sub-micron vesicles and particles suspended in high conductivity electrolytes using an electrokinetically biased Deterministic Lateral Displacement (DLD) device. An optimised, asymmetric array of micron-sized pillars and gaps, with an AC electric field applied orthogonal to the fluid flow gives an approximately ten-fold reduction in the intrinsic critical diameter (Dc) of the device. The asymmetry in the device maximises the throughput. Fractionation of populations of 100 nm and 400 nm extruded vesicles is achieved in 690 mS m-1 KCl, and 100 nm, 200 nm and 500 nm polystyrene particles in 105 mS m-1 KCl. The electrokinetically biased DLD may provide solutions for simple and rapid isolation of extracellular vesicles.
Collapse
Affiliation(s)
- Richard J Gillams
- School of Electronics and Computer Science, University of Southampton, UK.
- Institute for Life Sciences, University of Southampton, UK
| | - Victor Calero
- School of Electronics and Computer Science, University of Southampton, UK.
- International Iberian Nanotechnology Laboratory (INL), Braga, Portugal
| | | | - Hywel Morgan
- School of Electronics and Computer Science, University of Southampton, UK.
- Institute for Life Sciences, University of Southampton, UK
| |
Collapse
|
10
|
Vaghef-Koodehi A, Dillis C, Lapizco-Encinas BH. High-Resolution Charge-Based Electrokinetic Separation of Almost Identical Microparticles. Anal Chem 2022; 94:6451-6456. [PMID: 35441512 DOI: 10.1021/acs.analchem.2c00355] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Well-established techniques, e.g., chromatography and capillary electrophoresis, are available for separating nanosized particles, such as proteins. However, similar techniques for separating micron-sized particles are still needed. Insulator-based electrokinetic (iEK) systems can achieve efficient microparticle separations by combining linear and nonlinear EK phenomena. Of particular interest are charge-based separations, which could be employed for separating similar microorganisms, such as bacterial cells of the same size, same genus, or same strain. Several groups have reported charge-based separations of microparticles where a zeta potential difference of at least 40 mV between the microparticles was required. The present work pushes the limit of the discriminatory capabilities of iEK systems by reporting the charged-based separation of two microparticles of the same size (5.1 μm), same shape, same substrate material, and with a small difference in particle zeta potentials of only 3.6 mV, which is less than 10% of the difference in previous studies. By building an accurate COMSOL Multiphysics model, which correctly accounts for dielectrophoresis and electrophoresis of the second kind, it was possible to identify the conditions to achieve this challenging separation. Furthermore, the COMSOL model allowed predicting particle retention times (tR,p) which were compared with experimental values (tR,e). The separations results had excellent reproducibility in terms of tR,e with variations of only 9% and 11% between repetitions. These findings demonstrate that, by following a robust protocol that involves modeling and experimental work, it is possible to discriminate between highly similar particles, with much smaller differences in electrical charge than previously reported.
Collapse
Affiliation(s)
- Alaleh Vaghef-Koodehi
- Microscale Bioseparations Laboratory and Biomedical Engineering Department, Rochester Institute of Technology, 160 Lomb Memorial Drive, Rochester, New York 14623, United States
| | - Curran Dillis
- Microscale Bioseparations Laboratory and Biomedical Engineering Department, Rochester Institute of Technology, 160 Lomb Memorial Drive, Rochester, New York 14623, United States
| | - Blanca H Lapizco-Encinas
- Microscale Bioseparations Laboratory and Biomedical Engineering Department, Rochester Institute of Technology, 160 Lomb Memorial Drive, Rochester, New York 14623, United States
| |
Collapse
|
11
|
Fernández-Mateo R, Calero V, Morgan H, Ramos A, García-Sánchez P. Concentration-Polarization Electroosmosis near Insulating Constrictions within Microfluidic Channels. Anal Chem 2021; 93:14667-14674. [PMID: 34704741 PMCID: PMC8581963 DOI: 10.1021/acs.analchem.1c02849] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
![]()
Electric fields are
commonly used to trap and separate micro- and
nanoparticles near channel constrictions in microfluidic devices.
The trapping mechanism is attributed to the electrical forces arising
from the nonhomogeneous electric field caused by the constrictions,
and the phenomenon is known as insulator-based-dielectrophoresis (iDEP).
In this paper, we describe stationary electroosmotic flows of electrolytes
around insulating constrictions induced by low frequency AC electric
fields (below 10 kHz). Experimental characterization of the flows
is described for two different channel heights (50 and 10 μm),
together with numerical simulations based on an electrokinetic model
that considers the modification of the local ionic concentration due
to surface conductance on charged insulating walls. We term this phenomenon
concentration–polarization electroosmosis (CPEO). The observed
flow characteristics are in qualitative agreement with the predictions
of this model. However, for shallow channels (10 μm),
trapping of the particles on both sides of the constrictions is also
observed. This particle and fluid behavior could play a major role
in iDEP and could be easily misinterpreted as a dielectrophoretic
force.
Collapse
Affiliation(s)
- Raúl Fernández-Mateo
- School of Electronics and Computer Science, University of Southampton, Southampton SO17 1BJ, United Kingdom
| | - Víctor Calero
- Departamento de Electrónica y Electromagnetismo, Facultad de Física, Universidad de Sevilla, Avda. Reina Mercedes s/n, 41012 Sevilla, Spain
| | - Hywel Morgan
- School of Electronics and Computer Science, University of Southampton, Southampton SO17 1BJ, United Kingdom
| | - Antonio Ramos
- Departamento de Electrónica y Electromagnetismo, Facultad de Física, Universidad de Sevilla, Avda. Reina Mercedes s/n, 41012 Sevilla, Spain
| | - Pablo García-Sánchez
- Departamento de Electrónica y Electromagnetismo, Facultad de Física, Universidad de Sevilla, Avda. Reina Mercedes s/n, 41012 Sevilla, Spain
| |
Collapse
|
12
|
Lapizco-Encinas BH. The latest advances on nonlinear insulator-based electrokinetic microsystems under direct current and low-frequency alternating current fields: a review. Anal Bioanal Chem 2021; 414:885-905. [PMID: 34664103 DOI: 10.1007/s00216-021-03687-9] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2021] [Revised: 09/17/2021] [Accepted: 09/21/2021] [Indexed: 12/11/2022]
Abstract
This review article presents an overview of the evolution of the field of insulator-based dielectrophoresis (iDEP); in particular, it focuses on insulator-based electrokinetic (iEK) systems stimulated with direct current and low-frequency(< 1 kHz) AC electric fields. The article covers the surge of iDEP as a research field where many different device designs were developed, from microchannels with arrays of insulating posts to devices with curved walls and nano- and micropipettes. All of these systems allowed for the manipulation and separation of a wide array of particles, ranging from macromolecules to microorganisms, including clinical and biomedical applications. Recent experimental reports, supported by important theoretical studies in the field of physics and colloids, brought attention to the effects of electrophoresis of the second kind in these systems. These recent findings suggest that DEP is not the main force behind particle trapping, as it was believed for the last two decades. This new research suggests that particle trapping, under DC and low-frequency AC potentials, mainly results from a balance between electroosmotic and electrophoretic effects (linear and nonlinear); although DEP is present in these systems, it is not a dominant force. Considering these recent studies, it is proposed to rename this field from DC-iDEP to DC-iEK (and low-frequency AC-iDEP to low-frequency AC-iEK). Whereas much research is still needed, this is an exciting time in the field of microscale EK systems, as these new findings seem to explain the challenges with modeling particle migration and trapping in iEK devices, and provide perhaps a better understanding of the mechanisms behind particle trapping.
Collapse
Affiliation(s)
- Blanca H Lapizco-Encinas
- Microscale Bioseparations Laboratory and Biomedical Engineering Department, Rochester Institute of Technology, Institute Hall (Bldg. 73), Room 3103, 160 Lomb Memorial Drive, Rochester, NY, 14623-5604, USA.
| |
Collapse
|
13
|
Modeling Brownian Microparticle Trajectories in Lab-on-a-Chip Devices with Time Varying Dielectrophoretic or Optical Forces. MICROMACHINES 2021; 12:mi12101265. [PMID: 34683316 PMCID: PMC8539052 DOI: 10.3390/mi12101265] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/26/2021] [Revised: 10/13/2021] [Accepted: 10/15/2021] [Indexed: 01/02/2023]
Abstract
Lab-on-a-chip (LOC) devices capable of manipulating micro/nano-sized samples have spurred advances in biotechnology and chemistry. Designing and analyzing new and more advanced LOCs require accurate modeling and simulation of sample/particle dynamics inside such devices. In this work, we present a generalized computational physics model to simulate particle/sample trajectories under the influence of dielectrophoretic or optical forces inside LOC devices. The model takes into account time varying applied forces, Brownian motion, fluid flow, collision mechanics, and hindered diffusion caused by hydrodynamic interactions. We develop a numerical solver incorporating the aforementioned physics and use it to simulate two example cases: first, an optical trapping experiment, and second, a dielectrophoretic cell sorter device. In both cases, the numerical results are found to be consistent with experimental observations, thus proving the generality of the model. The numerical solver can simulate time evolution of the positions and velocities of an arbitrarily large number of particles simultaneously. This allows us to characterize and optimize a wide range of LOCs. The developed numerical solver is made freely available through a GitHub repository so that researchers can use it to develop and simulate new designs.
Collapse
|
14
|
Xuan X. Review of nonlinear electrokinetic flows in insulator-based dielectrophoresis: From induced charge to Joule heating effects. Electrophoresis 2021; 43:167-189. [PMID: 33991344 DOI: 10.1002/elps.202100090] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2021] [Revised: 05/08/2021] [Accepted: 05/11/2021] [Indexed: 01/03/2023]
Abstract
Insulator-based dielectrophoresis (iDEP) has been increasingly used for particle manipulation in various microfluidic applications. It exploits insulating structures to constrict and/or curve electric field lines to generate field gradients for particle dielectrophoresis. However, the presence of these insulators, especially those with sharp edges, causes two nonlinear electrokinetic flows, which, if sufficiently strong, may disturb the otherwise linear electrokinetic motion of particles and affect the iDEP performance. One is induced charge electroosmotic (ICEO) flow because of the polarization of the insulators, and the other is electrothermal flow because of the amplified Joule heating in the fluid around the insulators. Both flows vary nonlinearly with the applied electric field (either DC or AC) and exhibit in the form of fluid vortices, which have been utilized to promote some applications while being suppressed in others. The effectiveness of iDEP benefits from a comprehensive understanding of the nonlinear electrokinetic flows, which is complicated by the involvement of the entire iDEP device into electric polarization and thermal diffusion. This article is aimed to review the works on both the fundamentals and applications of ICEO and electrothermal flows in iDEP microdevices. A personal perspective of some future research directions in the field is also given.
Collapse
Affiliation(s)
- Xiangchun Xuan
- Department of Mechanical Engineering, Clemson University, Clemson, South Carolina, USA
| |
Collapse
|
15
|
Kwizera EA, Sun M, White AM, Li J, He X. Methods of Generating Dielectrophoretic Force for Microfluidic Manipulation of Bioparticles. ACS Biomater Sci Eng 2021; 7:2043-2063. [PMID: 33871975 DOI: 10.1021/acsbiomaterials.1c00083] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Manipulation of microscale bioparticles including living cells is of great significance to the broad bioengineering and biotechnology fields. Dielectrophoresis (DEP), which is defined as the interactions between dielectric particles and the electric field, is one of the most widely used techniques for the manipulation of bioparticles including cell separation, sorting, and trapping. Bioparticles experience a DEP force if they have a different polarization from the surrounding media in an electric field that is nonuniform in terms of the intensity and/or phase of the electric field. A comprehensive literature survey shows that the DEP-based microfluidic devices for manipulating bioparticles can be categorized according to the methods of creating the nonuniformity via patterned microchannels, electrodes, and media to generate the DEP force. These methods together with the theory of DEP force generation are described in this review, to provide a summary of the methods and materials that have been used to manipulate various bioparticles for various specific biological outcomes. Further developments of DEP-based technologies include identifying materials that better integrate with electrodes than current popular materials (silicone/glass) and improving the performance of DEP manipulation of bioparticles by combining it with other methods of handling bioparticles. Collectively, DEP-based microfluidic manipulation of bioparticles holds great potential for various biomedical applications.
Collapse
Affiliation(s)
- Elyahb A Kwizera
- Fischell Department of Bioengineering, University of Maryland, College Park, Maryland 20742, United States.,Robert E. Fischell Institute for Biomedical Devices, University of Maryland, College Park, Maryland 20742, United States
| | - Mingrui Sun
- Department of Biomedical Engineering, The Ohio State University, Columbus, Ohio 43210, United States
| | - Alisa M White
- Fischell Department of Bioengineering, University of Maryland, College Park, Maryland 20742, United States.,Robert E. Fischell Institute for Biomedical Devices, University of Maryland, College Park, Maryland 20742, United States
| | - Jianrong Li
- Department of Veterinary Biosciences, The Ohio State University, Columbus, Ohio 43210, United States
| | - Xiaoming He
- Fischell Department of Bioengineering, University of Maryland, College Park, Maryland 20742, United States.,Department of Biomedical Engineering, The Ohio State University, Columbus, Ohio 43210, United States.,Robert E. Fischell Institute for Biomedical Devices, University of Maryland, College Park, Maryland 20742, United States.,Marlene and Stewart Greenebaum Comprehensive Cancer Center, University of Maryland, Baltimore, Maryland 21201, United States
| |
Collapse
|
16
|
Lapizco-Encinas BH. Microscale nonlinear electrokinetics for the analysis of cellular materials in clinical applications: a review. Mikrochim Acta 2021; 188:104. [PMID: 33651196 DOI: 10.1007/s00604-021-04748-7] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2020] [Accepted: 02/06/2021] [Indexed: 12/16/2022]
Abstract
This review article presents a discussion of some of the latest advancements in the field of microscale electrokinetics for the analysis of cells and subcellular materials in clinical applications. The introduction presents an overview on the use of electric fields, i.e., electrokinetics, in microfluidics devices and discusses the potential of electrokinetic-based methods for the analysis of liquid biopsies in clinical and point-of-care applications. This is followed by four comprehensive sections that present some of the newest findings on the analysis of circulating tumor cells, blood (red blood cells, white blood cells, and platelets), stem cells, and subcellular particles (extracellular vesicles and mitochondria). The valuable contributions discussed here (with 131 references) were mainly published during the last 3 to 4 years, providing the reader with an overview of the state-of-the-art in the use of microscale electrokinetic methods in clinical analysis. Finally, the conclusions summarize the main advancements and discuss the future prospects.
Collapse
Affiliation(s)
- Blanca H Lapizco-Encinas
- Microscale Bioseparations Laboratory and Biomedical Engineering Department, Rochester Institute of Technology, Institute Hall (Bldg. 73), Room 3103, 160 Lomb Memorial Drive, Rochester, NY, 14623-5604, USA.
| |
Collapse
|
17
|
García-Sánchez P, Ramos A. Continuous Particle Separation in Microfluidics: Deterministic Lateral Displacement Assisted by Electric Fields. MICROMACHINES 2021; 12:66. [PMID: 33435288 PMCID: PMC7827387 DOI: 10.3390/mi12010066] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 01/05/2021] [Accepted: 01/07/2021] [Indexed: 02/07/2023]
Abstract
Advances in the miniaturization of microelectromechanical systems (MEMS) [...]
Collapse
Affiliation(s)
| | - Antonio Ramos
- Departamento de Electrónica y Electromagnetismo, Facultad de Física, Universidad de Sevilla, Avenida Reina Mercedes s/n, 41012 Sevilla, Spain;
| |
Collapse
|
18
|
Ho BD, Beech JP, Tegenfeldt JO. Charge-Based Separation of Micro- and Nanoparticles. MICROMACHINES 2020; 11:E1014. [PMID: 33218201 PMCID: PMC7702211 DOI: 10.3390/mi11111014] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/16/2020] [Revised: 11/11/2020] [Accepted: 11/14/2020] [Indexed: 12/13/2022]
Abstract
Deterministic Lateral Displacement (DLD) is a label-free particle sorting method that separates by size continuously and with high resolution. By combining DLD with electric fields (eDLD), we show separation of a variety of nano and micro-sized particles primarily by their zeta potential. Zeta potential is an indicator of electrokinetic charge-the charge corresponding to the electric field at the shear plane-an important property of micro- and nanoparticles in colloidal or separation science. We also demonstrate proof of principle of separation of nanoscale liposomes of different lipid compositions, with strong relevance for biomedicine. We perform careful characterization of relevant experimental conditions necessary to obtain adequate sorting of different particle types. By choosing a combination of frequency and amplitude, sorting can be made sensitive to the particle subgroup of interest. The enhanced displacement effect due to electrokinetics is found to be significant at low frequency and for particles with high zeta potential. The effect appears to scale with the square of the voltage, suggesting that it is associated with either non-linear electrokinetics or dielectrophoresis (DEP). However, since we observe large changes in separation behavior over the frequency range at which DEP forces are expected to remain constant, DEP can be ruled out.
Collapse
Affiliation(s)
| | | | - Jonas O. Tegenfeldt
- Division of Solid State Physics and NanoLund, Physics Department, Lund University, P.O. Box 118, 22100 Lund, Sweden; (B.D.H.); (J.P.B.)
| |
Collapse
|
19
|
Pesch GR, Du F. A review of dielectrophoretic separation and classification of non-biological particles. Electrophoresis 2020; 42:134-152. [PMID: 32667696 DOI: 10.1002/elps.202000137] [Citation(s) in RCA: 31] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2020] [Revised: 07/08/2020] [Accepted: 07/08/2020] [Indexed: 02/06/2023]
Abstract
Dielectrophoresis (DEP) is a selective electrokinetic particle manipulation technology that is applied for almost 100 years and currently finds most applications in biomedical research using microfluidic devices operating at moderate to low throughput. This paper reviews DEP separators capable of high-throughput operation and research addressing separation and analysis of non-biological particle systems. Apart from discussing particle polarization mechanisms, this review summarizes the early applications of DEP for dielectric sorting of minerals and lists contemporary applications in solid/liquid, liquid/liquid, and solid/air separation, for example, DEP filtration or airborne fiber length classification; the review also summarizes developments in DEP fouling suppression, gives a brief overview of electrocoalescence and addresses current problems in high-throughput DEP separation. We aim to provide inspiration for DEP application schemes outside of the biomedical sector, for example, for the recovery of precious metal from scrap or for extraction of metal from low-grade ore.
Collapse
Affiliation(s)
- Georg R Pesch
- Faculty of Production Engineering, Chemical Process Engineering Group, University of Bremen, Bremen, Germany
| | - Fei Du
- Faculty of Production Engineering, Chemical Process Engineering Group, University of Bremen, Bremen, Germany
| |
Collapse
|
20
|
Calero V, García-Sánchez P, Ramos A, Morgan H. Electrokinetic biased deterministic lateral displacement: scaling analysis and simulations. J Chromatogr A 2020; 1623:461151. [DOI: 10.1016/j.chroma.2020.461151] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2020] [Revised: 04/12/2020] [Accepted: 04/20/2020] [Indexed: 11/25/2022]
|
21
|
Pethig R. Festschrift for Professor Hsueh-Chia Chang. BIOMICROFLUIDICS 2019; 13:060401. [PMID: 31867085 PMCID: PMC6908456 DOI: 10.1063/1.5141082] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/03/2019] [Accepted: 12/03/2019] [Indexed: 06/10/2023]
Abstract
This special collection of Biomicrofluidics serves as a Festschrift to honor Professor Hsueh-Chia Chang, Bayer Professor at the Department of Chemical and Biomolecular Engineering, University of Notre Dame. We acknowledge not only his role as Chief and Founding Editor of Biomicrofluidics (from 2006 through 2018) but also his seminal contributions as a researcher in micro/nanofluidics, particularly in the area of nanoelectrokinetics. This research has also been recognized by the 2018 Lifetime Achievement Award of the AES Electrophoresis Society to him.
Collapse
|