1
|
Ugarte-Anero A, Fernandez-Gamiz U, Portal-Porras K, Lopez-Guede JM, Sanchez-Merino G. Numerical study of different ventilation schemes in a classroom for efficient aerosol control. Heliyon 2023; 9:e19961. [PMID: 37809677 PMCID: PMC10559565 DOI: 10.1016/j.heliyon.2023.e19961] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2022] [Revised: 07/11/2023] [Accepted: 09/07/2023] [Indexed: 10/10/2023] Open
Abstract
The air quality is a parameter to be controlled in order to live in a comfortable place. This paper analyzes the trajectory of aerosols exhaled into the environment in a classroom. Three scenarios are investigated; without ventilation, with natural and with mechanical ventilation. A multi-phase computational fluid study based on Eulerian-Lagrangian techniques is defined. Temperature and ambient relative humidity, as well as air velocity, direction and pressure is taken into account. For droplets evaporation, mass transfer and turbulent dispersion have been added. This work tends to be of great help in various areas, such as the field of medicine and energy engineering, aiming to show the path of aerosols dispersed in the air. The results show that the classroom with a mechanical ventilation scheme offers good results when it comes to an efficient control of aerosols. In all three cases, aerosols exhaled into the environment impregnate the front row student in the first 0.5 s. Reaching the time of 4, 2 and 1 s, in the class without ventilation, mechanical and natural ventilation, respectively, the aerosols have been already deposited on the table of the person in the first row, being exposed for longer in the case of no ventilation. Particles with a diameter of less than 20 μm are distributed throughout the classroom over a long period. The air jet injected into the interior space offers a practically constant relative humidity and a drop in temperature, slowing down the process of evaporation of the particles. In the first second, it can be seen that a mass of 0.0025 mg formed by 9 million droplets accumulates, in cases without ventilation and natural ventilation. The room with a mechanical installation accumulated 5.5 million particles of mass 0.0028 mg in the first second. The energy losses generated by natural ventilation are high compared to the other scenarios, exactly forty and twenty times more in the scenario with mechanical ventilation and without ventilation, respectively.
Collapse
Affiliation(s)
- Ainara Ugarte-Anero
- Nuclear Engineering and Fluid Mechanics Department, University of the Basque Country, UPV/EHU, Nieves Cano 12, Vitoria-Gasteiz, 01006, Araba, Spain
- Bioaraba, New Technologies and Information Systems in Health Research Group, Vitoria-Gasteiz, Spain
- Osakidetza Basque Health Service, Araba University Hospital, Medical Physics Department, Vitoria-Gasteiz, Spain
| | - Unai Fernandez-Gamiz
- Nuclear Engineering and Fluid Mechanics Department, University of the Basque Country, UPV/EHU, Nieves Cano 12, Vitoria-Gasteiz, 01006, Araba, Spain
- Bioaraba, New Technologies and Information Systems in Health Research Group, Vitoria-Gasteiz, Spain
- Osakidetza Basque Health Service, Araba University Hospital, Medical Physics Department, Vitoria-Gasteiz, Spain
| | - Koldo Portal-Porras
- Nuclear Engineering and Fluid Mechanics Department, University of the Basque Country, UPV/EHU, Nieves Cano 12, Vitoria-Gasteiz, 01006, Araba, Spain
| | - Jose Manuel Lopez-Guede
- Bioaraba, New Technologies and Information Systems in Health Research Group, Vitoria-Gasteiz, Spain
- Osakidetza Basque Health Service, Araba University Hospital, Medical Physics Department, Vitoria-Gasteiz, Spain
- System Engineering and Automation Control Department, University of the Basque Country, UPV/EHU, Nieves Cano 12, Vitoria-Gasteiz, 01006, Araba, Spain
| | - Gaspar Sanchez-Merino
- Bioaraba, New Technologies and Information Systems in Health Research Group, Vitoria-Gasteiz, Spain
- Osakidetza Basque Health Service, Araba University Hospital, Medical Physics Department, Vitoria-Gasteiz, Spain
| |
Collapse
|
2
|
Liu S, Deng Z. Transmission and infection risk of COVID-19 when people coughing in an elevator. BUILDING AND ENVIRONMENT 2023; 238:110343. [PMID: 37143581 PMCID: PMC10122966 DOI: 10.1016/j.buildenv.2023.110343] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/31/2023] [Revised: 04/02/2023] [Accepted: 04/20/2023] [Indexed: 05/06/2023]
Abstract
People in cities use elevators daily. With the COVID-19 pandemic, there are more worries about elevator safety, since elevators are often small and crowded. This study used a proven CFD model to see how the virus could spread in elevators. We simulated five people taking in an elevator for 2 min and analyzed the effect of different factors on the amount of virus that could be inhaled, such as the infected person's location, the standing positions of the persons, and the air flow rate. We found that the position of the infected person and the direction they stood greatly impacted virus transmission in the elevator. The use of mechanical ventilation with a flow rate of 30 ACH (air changes per hour) was effective in reducing the risk of infection. In situations where the air flow rate was 3 ACH, we found that the highest number of inhaled virus copies could range from 237 to 1186. However, with a flow rate of 30 ACH, the highest number was reduced to 153 to 509. The study also showed that wearing surgical masks decreased the highest number of inhaled virus copies to 74 to 155.
Collapse
Affiliation(s)
- Sumei Liu
- Tianjin Key Laboratory of Indoor Air Environmental Quality Control, School of Environmental Science and Engineering, Tianjin University, Tianjin, 300072, China
| | - Zhipeng Deng
- Department of Mechanical & Aerospace Engineering, Syracuse University, Syracuse, NY, 13244, United States
| |
Collapse
|
3
|
Li X, Feng B. Transmission of droplet aerosols in an elevator cabin: Effect of the ventilation mode. BUILDING AND ENVIRONMENT 2023; 236:110261. [PMID: 37041765 PMCID: PMC10066590 DOI: 10.1016/j.buildenv.2023.110261] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/11/2022] [Revised: 03/13/2023] [Accepted: 03/29/2023] [Indexed: 06/19/2023]
Abstract
The recent outbreak of COVID-19 has threatened public health. Owing to the relatively sealed environment and poor ventilation in elevator cabins, passengers are at risk of respiratory tract infection. However, the distribution and dispersion of droplet aerosols in elevator cabins remain unclear. This study investigated the transmission of droplet aerosols exhaled by a source patient under three ventilation modes. Droplet aerosols produced by nose breathing and mouth coughing were resolved using computational fluid dynamics (CFD) simulations. We adopted the verified renormalization group (RNG) k-ε turbulence model to simulate the flow field and the Lagrangian method to track the droplet aerosols. In addition, the influence of the ventilation mode on droplet transmission was evaluated. The results showed that droplet aerosols gathered in the elevator cabin and were difficult to discharge under the mixed and displacement ventilation modes with specific initial conditions. The inhalation proportion of droplet aerosols for air curtain was 0.016%, which was significantly lower than that for mixed ventilation (0.049%) and displacement ventilation (0.071%). The air curtain confined the transmission of droplet aerosols with the minimum ratios of inhalation, deposition, and suspension and is thus recommended to reduce the exposure risk.
Collapse
Affiliation(s)
- Xian Li
- School of Civil Engineering and Architecture, Linyi University, Linyi, 276000, China
| | - Bujin Feng
- College of Agriculture, Shandong Agricultural University, Taian, 271018, China
| |
Collapse
|
4
|
A review on indoor airborne transmission of COVID-19– modelling and mitigation approaches. JOURNAL OF BUILDING ENGINEERING 2023; 64:105599. [PMCID: PMC9699823 DOI: 10.1016/j.jobe.2022.105599] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/06/2022] [Revised: 11/11/2022] [Accepted: 11/21/2022] [Indexed: 06/09/2023]
Abstract
In the past few years, significant efforts have been made to investigate the transmission of COVID-19. This paper provides a review of the COVID-19 airborne transmission modeling and mitigation strategies. The simulation models here are classified into airborne transmission infectious risk models and numerical approaches for spatiotemporal airborne transmissions. Mathematical descriptions and assumptions on which these models have been based are discussed. Input data used in previous simulation studies to assess the dispersion of COVID-19 are extracted and reported. Moreover, measurements performed to study the COVID-19 airborne transmission within indoor environments are introduced to support validations for anticipated future modeling studies. Transmission mitigation strategies recommended in recent studies have been classified to include modifying occupancy and ventilation operations, using filters and air purifiers, installing ultraviolet (UV) air disinfection systems, and personal protection compliance, such as wearing masks and social distancing. The application of mitigation strategies to various building types, such as educational, office, public, residential, and hospital, is reviewed. Recommendations for future works are also discussed based on the current apparent knowledge gaps covering both modeling and mitigation approaches. Our findings show that different transmission mitigation measures were recommended for various indoor environments; however, there is no conclusive work reporting their combined effects on the level of mitigation that may be achieved. Moreover, further studies should be conducted to understand better the balance between approaches to mitigating the viral transmissions in buildings and building energy consumption.
Collapse
|
5
|
Chillón SA, Fernandez-Gamiz U, Zulueta E, Ugarte-Anero A, Urbina-Garcia O. Numerical modeling of a sneeze, a cough and a continuum speech inside a hospital lift. Heliyon 2023; 9:e13370. [PMID: 36744064 PMCID: PMC9889118 DOI: 10.1016/j.heliyon.2023.e13370] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2022] [Revised: 01/13/2023] [Accepted: 01/28/2023] [Indexed: 02/04/2023] Open
Abstract
The global COVID-19 and its variants put us on notice of the importance of studying the spread of respiratory diseases. The most common means of propagation was the emission of droplets due to different respiration activities. This study modeled by computational fluid dynamics (CFD) techniques a high risk scenario like a hospital elevator. The cabin was provided with an extraction fan and a rack for air renewal. Inside, a sneeze, a cough and a continuum speech were simulated. Inside the lift, two occupants were introduced to observe the risk of propagation of emitted droplets and the impact in diseases spreading risk. The fan effectivity over the droplets ejection was analyzed, as well as environmental condition of a clinical setting. For this purpose the amount of droplets inside were counted during whole time of simulations. The effect of the fan was concluded as able to eject the 60% of small droplets, but also a high performance in spreading particles inside. Among the three cases, the riskiest scenario was the continuum speech due to the saturation of droplets in airborne.
Collapse
Affiliation(s)
- Sergio A. Chillón
- Nuclear Engineering and Fluid Mechanics Department, University of the Basque Country, UPV/EHU, Nieves Cano 12, Vitoria-Gasteiz, 01006, Araba, Spain
| | - Unai Fernandez-Gamiz
- Nuclear Engineering and Fluid Mechanics Department, University of the Basque Country, UPV/EHU, Nieves Cano 12, Vitoria-Gasteiz, 01006, Araba, Spain,Corresponding author
| | - Ekaitz Zulueta
- Automatic and Simulation Department, University of the Basque Country, UPV/EHU, Nieves Cano 12, Vitoria-Gasteiz, 01006, Araba, Spain
| | - Ainara Ugarte-Anero
- Nuclear Engineering and Fluid Mechanics Department, University of the Basque Country, UPV/EHU, Nieves Cano 12, Vitoria-Gasteiz, 01006, Araba, Spain
| | - Oskar Urbina-Garcia
- Nuclear Engineering and Fluid Mechanics Department, University of the Basque Country, UPV/EHU, Nieves Cano 12, Vitoria-Gasteiz, 01006, Araba, Spain
| |
Collapse
|
6
|
Takamure K, Sakamoto Y, Iwatani Y, Amano H, Yagi T, Uchiyama T. Characteristics of collection and inactivation of virus in air flowing inside a winding conduit equipped with 280 nm deep UV-LEDs. ENVIRONMENT INTERNATIONAL 2022; 170:107580. [PMID: 36252438 DOI: 10.1016/j.envint.2022.107580] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/06/2022] [Revised: 10/06/2022] [Accepted: 10/10/2022] [Indexed: 06/16/2023]
Abstract
A general-purpose virus inactivation unit that can inactivate viruses was developed using deep ultraviolet (DUV) LEDs that emit DUV rays with a wavelength of 280 nm. The inside of the virus inactivation unit is a rectangular conduit with a sharp turn of 180° (sharp-turned rectangular conduit). Virus inactivation is attempted by directly irradiating the air passing through the conduit with DUV rays. The flow characteristics of air and virus particles inside the virus inactivation unit were investigated using numerical simulations. The air was locally accelerated at the sharp turn parts and flowed along the partition plate in the sharp-turned rectangular conduit. The aerosol particles moving in the sharp-turned rectangular conduit were greatly bent in orbit at the sharp turn parts, and then rapidly approached the partition plate at the lower part of the conduit. Consequently, many particles collided with the partition plates behind the sharp-turn parts. SARS-CoV-2 virus was nebulized in the virus inactivation unit, and the RNA concentration and virus inactivation rate with and without the emission of DUV-LEDs were measured in the experiment. The concentration of SARS-CoV-2 RNA was reduced to 60% through DUV-LED irradiation. In addition, SARS-CoV-2 passing through the virus inactivation unit was inactivated below the detection limit by the emission of DUV-LEDs. The virus inactivation rate and the value of the detection limit corresponded to 99.38% and 35.36 TCID50/mL, respectively.
Collapse
Affiliation(s)
- Kotaro Takamure
- Institute of Materials and Systems for Sustainability, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8601, Japan.
| | - Yasuaki Sakamoto
- Graduate School of Informatics, Nagoya University, Nagoya 464-8601, Japan
| | - Yasumasa Iwatani
- Clinical Research Center, National Hospital Organization Nagoya Medical Center, Nagoya 460-0001, Japan.
| | - Hiroshi Amano
- Institute of Materials and Systems for Sustainability, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8601, Japan.
| | - Tetsuya Yagi
- Department of Infectious Diseases, Nagoya University Hospital, Nagoya 466-0065, Japan.
| | - Tomomi Uchiyama
- Institute of Materials and Systems for Sustainability, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8601, Japan.
| |
Collapse
|
7
|
Takii A, Yamakawa M, Kitagawa A, Watamura T, Chung YM, Kim M. Numerical model for cough-generated droplet dispersion on moving escalator with multiple passengers. INDOOR AIR 2022; 32:e13131. [PMID: 36437661 PMCID: PMC9827918 DOI: 10.1111/ina.13131] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/24/2022] [Revised: 09/15/2022] [Accepted: 09/23/2022] [Indexed: 06/16/2023]
Abstract
To investigate the motion of virus-laden droplets between moving passengers in line, we performed numerical simulations of the distribution of airborne droplets within a geometrically detailed model similar to an actual escalator. The left and right sides and the ceiling of the escalator model were surrounded by walls, assuming a subway used by many people every day with concern to virus-laden droplets. Steps and handrails were incorporated in the model to faithfully compute the escalator-specific flow field. The ascending and descending movements of the escalator were performed with 10 or 5 passengers standing at different boarding intervals. To resolve the unsteady airflow that is excited by a moving boundary consisting of passengers, steps, and handrails, the moving computational domain method based on the moving-grid finite-volume method was applied. On the basis of the consideration that the droplets were small enough, droplet dispersion was computed by solving the equation of virus-laden droplet motion using a pre-computed velocity field, in which the flow rate of a cough, diameter distribution, and evaporation of droplets are incorporated. The simulation resolved the detailed motion of droplets in flow, and therefore, we were able to evaluate the risk of viral adhesion to following passengers. As a result, we found that the ascending escalator had a higher risk of being exposed to virus-laden droplets than the descending escalator. We also reported that the chance of viral droplet adhesion decreases as the distance from the infected person increases, emphasizing the importance of social distancing.
Collapse
Affiliation(s)
- Ayato Takii
- Department of Mechanical EngineeringKyoto Institute of TechnologyKyotoJapan
| | - Masashi Yamakawa
- Department of Mechanical EngineeringKyoto Institute of TechnologyKyotoJapan
| | - Atsuhide Kitagawa
- Department of Mechanical EngineeringKyoto Institute of TechnologyKyotoJapan
| | - Tomoaki Watamura
- Department of Mechanical EngineeringKyoto Institute of TechnologyKyotoJapan
| | | | - Minsuok Kim
- School of Mechanical, Electrical and Manufacturing EngineeringLoughborough UniversityLoughboroughUK
| |
Collapse
|
8
|
Zhao Y, Feng Y, Ma L. Impacts of human movement and ventilation mode on the indoor environment, droplet evaporation, and aerosol transmission risk at airport terminals. BUILDING AND ENVIRONMENT 2022; 224:109527. [PMID: 36060217 PMCID: PMC9428122 DOI: 10.1016/j.buildenv.2022.109527] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/25/2022] [Revised: 07/16/2022] [Accepted: 08/20/2022] [Indexed: 05/29/2023]
Abstract
The dispersion of the coronavirus pandemic has caused immense damage worldwide, and people have begun to ruminate epidemic prevention strategies for public places. Airport terminals with a high number of occupied passengers have become potentially high-risk regions for aerosol transmission of coronavirus disease 2019 (COVID-19). In this study, the Eulerian-Lagrangian approach and realizable k-ε turbulence model were used to numerically simulate airflow organization and aerosol transmission when passengers are moving slowly in a line. During the aerosol transmission period, evaporation was considered a key factor influencing the particle size distribution at the beginning of aerosol transmission from humans. Moreover, passenger movement at the airport terminal was attained by employing dynamic mesh algorithms. Based on the relative direction of passengers and air vents when queuing in the terminal building, we studied three conditions: windward walking, leeward walking, and crosswind walking. The results of this study showed that the walking has an important influence on droplet distribution. Droplet distribution indicates that individuals standing behind patients during queuing movements have a higher risk of infection than those standing in front of them. A significant aerosol accumulation was discovered at 0.5 m behind the patient when passengers moved simultaneously. An aerosol transmission distance of 15 s aligned with the passenger's walking direction could reach up to 9.32 m. Furthermore, although the evaporation time of the large droplets was longer than that of the small droplets, both large and small droplets evaporated rapidly after exhalation. The crosswind influence caused the droplets to travel farther away in a direction perpendicular to human movement, which increased the distance by approximately 1.26 m compared to the absence of the crosswind influence.
Collapse
Affiliation(s)
- Yu Zhao
- School of Civil Engineering, Faculty of Infrastructure Engineering, Dalian University of Technology, 2 Linggong Road, Ganjingzi District, Dalian, 116024, China
| | - Yao Feng
- School of Civil Engineering, Faculty of Infrastructure Engineering, Dalian University of Technology, 2 Linggong Road, Ganjingzi District, Dalian, 116024, China
| | - Liangdong Ma
- School of Civil Engineering, Faculty of Infrastructure Engineering, Dalian University of Technology, 2 Linggong Road, Ganjingzi District, Dalian, 116024, China
| |
Collapse
|
9
|
Issakhov A, Omarova P, Borsikbayeva A. Assessment of airborne transmission from coughing processes with thermal plume adjacent to body and radiators on effectiveness of social distancing. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2022; 29:66808-66840. [PMID: 35508854 DOI: 10.1007/s11356-022-18713-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/13/2021] [Accepted: 01/13/2022] [Indexed: 06/14/2023]
Abstract
The new coronavirus disease COVID-19 has caused a worldwide pandemic to be declared in a very short period of time. The complexity of the infection lies in asymptomatic carriers that can inadvertently transmit the virus through airborne droplets. This kind of viral disease can infect the human body with tiny particles that carry various bacteria that are generated by the respiratory system of infected patients. In this study, numerical results are proposed that demonstrate the effect of human body temperature and temperature from radiators in a room on the spread of the smallest droplets and particles in an enclosed space. The numerical model proposed in this work takes into account the sedimentation of particles and droplets under the action of gravitational sedimentation and transport in a closed room during the processes of breathing, sneezing or coughing. Various cases were considered, taking into account normal human breathing, coughing or sneezing, as well as three different values of the rate of emission of particles from the human mouth. The heat plume, which affects the concentration of particles in the breathing zone, spreads the particle up to a distance of 4.29 m in the direction of the air flow. It can also be seen from the results obtained that the presence of radiators strongly affects the propagation of particles of various sizes in a closed room. From the obtained results, it should be noted that in order to recommend the optimal social distance, it is necessary to take into account many factors, especially momentum, gravity, human body temperature, as well as the process of natural convection, which greatly affect the propagation of particles in a closed room. The conclusions drawn from the results of this work show that, given the environmental conditions, the social distance of 2 m may not be enough.
Collapse
Affiliation(s)
- Alibek Issakhov
- Al-Farabi, Kazakh National University, Almaty, Republic of Kazakhstan.
- Kazakh British Technical University, Almaty, Republic of Kazakhstan.
- International Information Technology University, Almaty, Republic of Kazakhstan.
| | - Perizat Omarova
- Al-Farabi, Kazakh National University, Almaty, Republic of Kazakhstan
| | | |
Collapse
|
10
|
Talha M, Akhtar I, Haseeb M. Transmission of Cough Aerosols in a Hospital Room Related to COVID-19. 2022 19TH INTERNATIONAL BHURBAN CONFERENCE ON APPLIED SCIENCES AND TECHNOLOGY (IBCAST) 2022. [DOI: 10.1109/ibcast54850.2022.9990217] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/01/2023]
Affiliation(s)
- Muhammad Talha
- National University of Sciences & Technology (NUST),Department of Mechanical Engineering, College of Electrical and Mechanical Engineering,Islamabad,Pakistan,44000
| | - Imran Akhtar
- National University of Sciences & Technology (NUST),Department of Mechanical Engineering, College of Electrical and Mechanical Engineering,Islamabad,Pakistan,44000
| | - Muhammad Haseeb
- National University of Sciences & Technology (NUST),Department of Mechanical Engineering, College of Electrical and Mechanical Engineering,Islamabad,Pakistan,44000
| |
Collapse
|
11
|
Ugarte-Anero A, Fernandez-Gamiz U, Portal-Porras K, Zulueta E, Urbina-Garcia O. Computational characterization of the behavior of a saliva droplet in a social environment. Sci Rep 2022; 12:6405. [PMID: 35437309 PMCID: PMC9016067 DOI: 10.1038/s41598-022-10180-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2022] [Accepted: 04/04/2022] [Indexed: 11/21/2022] Open
Abstract
The conduct of respiratory droplets is the basis of the study to reduce the spread of a virus in society. The pandemic suffered in early 2020 due to COVID-19 shows the lack of research on the evaporation and fate of droplets exhaled in the environment. The current study, attempts to provide solution through computational fluid dynamics techniques based on a multiphase state with the help of Eulerian–Lagrangian techniques to the activity of respiratory droplets. A numerical study has shown how the behavior of droplets of pure water exhaled in the environment after a sneeze or cough have a dynamic equal to the experimental curve of Wells. The droplets of saliva have been introduced as a saline solution. Considering the mass transferred and the turbulence created, the results has showed that the ambient temperature and relative humidity are parameters that significantly affect the evaporation process, and therefore to the fate. Evaporation time tends to be of a higher value when the temperature affecting the environment is lower. With constant parameters of particle diameter and ambient temperature, an increase in relative humidity increases the evaporation time. A larger particle diameter is consequently transported at a greater distance, since the opposite force it affects is the weight. Finally, a neural network-based model is presented to predict particle evaporation time.
Collapse
|
12
|
Das SK, Alam JE, Plumari S, Greco V. Airborne virus transmission under different weather conditions. AIP ADVANCES 2022; 12:015019. [PMID: 35070489 PMCID: PMC8759630 DOI: 10.1063/5.0082017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/11/2021] [Accepted: 12/22/2021] [Indexed: 05/07/2023]
Abstract
The COVID19 infection is known to disseminate through droplets ejected by infected individuals during coughing, sneezing, speaking, and breathing. The spread of the infection and hence its menace depend on how the virus-loaded droplets evolve in space and time with changing environmental conditions. In view of this, we investigate the evolution of the droplets within the purview of the Brownian motion of the evaporating droplets in the air with varying weather conditions under the action of gravity. We track the movement of the droplets until either they gravitationally settle on the ground or evaporate to aerosols of size 2 μm or less. Droplets with radii 2 μm or less may continue to diffuse and remain suspended in the air for a long time. The effects of relative humidity and temperature on the evaporation are found to be significant. We note that under strong flowing conditions, droplets travel large distances. It is found that the bigger droplets fall on the ground due to the dominance of gravity over the diffusive force despite the loss of mass due to evaporation. The smaller evaporating droplets may not settle on the ground but remain suspended in the air due to the dominance of the diffusive force. The fate of the intermediate size droplets depends on the weather conditions and plays crucial roles in the spread of the infection. These environment dependent effects indicate that the maintenance of physical separation to evade the virus is not corroborated, making the use of face masks indispensable.
Collapse
Affiliation(s)
- Santosh K. Das
- School of Physical Sciences, Indian Institute of Technology Goa, Ponda 403401, Goa, India
| | | | | | | |
Collapse
|
13
|
Biswas R, Pal A, Pal R, Sarkar S, Mukhopadhyay A. Risk assessment of COVID infection by respiratory droplets from cough for various ventilation scenarios inside an elevator: An OpenFOAM-based computational fluid dynamics analysis. PHYSICS OF FLUIDS (WOODBURY, N.Y. : 1994) 2022; 34:013318. [PMID: 35340680 PMCID: PMC8939552 DOI: 10.1063/5.0073694] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/02/2021] [Accepted: 12/30/2021] [Indexed: 05/15/2023]
Abstract
Respiratory droplets-which may contain disease spreading virus-exhaled during speaking, coughing, or sneezing are one of the significant causes for the spread of the ongoing COVID-19 pandemic. The droplet dispersion depends on the surrounding air velocity, ambient temperature, and relative humidity. In a confined space like an elevator, the risk of transmission becomes higher when there is an infected person inside the elevator with other individuals. In this work, a numerical investigation is carried out in a three-dimensional domain resembling an elevator using OpenFoam. Three different modes of air ventilation, viz., quiescent, axial exhaust draft, and exhaust fan, have been considered to investigate the effect of ventilation on droplet transmission for two different climatic conditions (30 °C , 50% relative humidity and 10 °C , 90% relative humidity). The risk assessment is quantified using a risk factor based on the time-averaged droplet count present near the passenger's hand to head region (risky height zone). The risk factor drops from 40% in a quiescent scenario to 0% in an exhaust fan ventilation condition in a hot dry environment. In general, cold humid conditions are safer than hot dry conditions as the droplets settle down quickly below the risky height zone owing to their larger masses maintained by negligible evaporation. However, an exhaust fan renders the domain in a hot dry ambience completely safe (risk factor, 0%) in 5.5 s whereas it takes 7.48 s for a cold humid ambience.
Collapse
Affiliation(s)
- Riddhideep Biswas
- Department of Mechanical Engineering, Jadavpur University, Kolkata-700032, India
| | - Anish Pal
- Department of Mechanical Engineering, Jadavpur University, Kolkata-700032, India
| | - Ritam Pal
- Department of Mechanical Engineering, The Pennsylvania State University, University Park, Pennsylvania 16802, USA
| | - Sourav Sarkar
- Department of Mechanical Engineering, Jadavpur University, Kolkata-700032, India
- Author to whom correspondence should be addressed:
| | | |
Collapse
|
14
|
Wang H, Li Z, Liu Y, Zhu L, Zhou Z. Experimental study of the dispersion of cough-generated droplets from a person going up- or downstairs. AIP ADVANCES 2022; 12:015002. [PMID: 35003882 PMCID: PMC8734944 DOI: 10.1063/5.0073880] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/04/2021] [Accepted: 11/22/2021] [Indexed: 06/14/2023]
Abstract
The dispersion of cough-generated droplets from a person going up- or downstairs was investigated through a laboratory experiment in a water tunnel. This experiment was carried out with a manikin mounted at inclination angles facing the incoming flow to mimic a person going up or down. Detailed velocity measurements and flow visualization were conducted in the water tunnel experiments. To investigate the influence of the initial position on the motion of particles, a virtual particle approach was adopted to simulate the dispersion of particles using the measured velocity field. Particle clustering, which is caused by the unsteadiness of the flow, was observed in both flow visualization and virtual particle simulation. For the case of going upstairs, particles are concentrated below the person's shoulder and move downward with a short travel distance. For the case of going downstairs, particles dispersing over the person's head advect over for a long distance. We also found that the motion of the particles is closely related to the initial position. According to the results in this study, suggestions for the prevention of respiratory infectious disease are made.
Collapse
|
15
|
Peña-Monferrer C, Antao S, Manson-Sawko R. Numerical investigation of droplets in a cross-ventilated space with sitting passengers under asymptomatic virus transmission conditions. PHYSICS OF FLUIDS (WOODBURY, N.Y. : 1994) 2021; 33:123314. [PMID: 35002204 PMCID: PMC8728630 DOI: 10.1063/5.0070625] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/08/2021] [Accepted: 11/05/2021] [Indexed: 06/14/2023]
Abstract
Asymptomatic virus transmission in public transportation is a complex process that is difficult to analyze computationally and experimentally. We present a high-resolution computational study for investigating droplet dynamics under a speech-like exhalation mode. A large eddy simulation coupled with Lagrangian tracking of drops was used to model a rectangular space with sitting thermal bodies and cross-ventilated with a multislot diffuser. Release of drops from different seat positions was evaluated to analyze the decontamination performance of the ventilation system. The results showed an overall good performance, with an average of 24.1% of droplets removed through the exhaust in the first 40 s. The droplets' distribution revealed that higher concentrations were less prevalent along the center of the domain where the passengers sit. Longitudinal contamination between rows was noted, which is a negative aspect for containing the risk of infection in a given row but has the benefit of diluting the concentration of infectious droplets. Droplets from the window seat raised more vertically and invaded the space of other passengers to a lesser extent. In contrast, droplets released from the middle seat contaminated more the aisle passenger's space, indicating that downward flow from personal ventilation could move down droplets to its breathing region. Droplets released from the aisle were dragged down by the ventilation system immediately. The distance of drops to the mouth of the passengers showed that the majority passed at a relatively safe distance. However, a few of them passed at a close distance of the order of magnitude of 1 cm.
Collapse
Affiliation(s)
- C Peña-Monferrer
- IBM Research Europe, The Hartree Centre, Warrington WA4 4AD, United Kingdom
| | - S Antao
- IBM Research Europe, The Hartree Centre, Warrington WA4 4AD, United Kingdom
| | - R Manson-Sawko
- IBM Research Europe, The Hartree Centre, Warrington WA4 4AD, United Kingdom
| |
Collapse
|
16
|
Dey P, Saha SK, Sarkar S. Study of the interactions of sneezing droplets with particulate matter in a polluted environment. PHYSICS OF FLUIDS (WOODBURY, N.Y. : 1994) 2021; 33:113310. [PMID: 34803363 PMCID: PMC8597716 DOI: 10.1063/5.0067517] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/17/2021] [Accepted: 10/15/2021] [Indexed: 05/04/2023]
Abstract
We have performed a three-dimensional numerical simulation to determine the effect of local atmospheric pollution level on the spreading characteristics of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) virus through ejected droplets during sneezing and coughing in an open space. Utilizing a finite volume-based numerical method, we have performed computations for various ranges of droplet diameters and sneezing speeds. The interactions between the droplets and the suspended particles are considered by taking both hydrophobic and hydrophilic wettability characteristics into account. Our computational results show that the virus-containing droplets partially affect aerosols during the path of their transmission. With the progression of time, the droplet distribution shows an asymmetric pattern. The maximum dispersion of these droplets is found for higher sneezing velocities. The droplets with a diameter of 50 μm travel a larger distance than the larger diameter droplets. We have found that an aerosol with hydrophilic wettability undergoes complete wetting by the disease-containing droplets and therefore is conducive to disease propagation. The droplet engagement duration with aerosol decreases with increase in the sneezing velocity. Our study recommends against using physical exercise centers in a closed environment such as gymnasium and indoor games during the COVID pandemic, especially in a polluted environment. The results from our work will help in deciding proper social distancing guidelines based on the local atmospheric pollution level. They may act as a precursor in controlling further spread of diseases during this unprecedented situation of the COVID pandemic.
Collapse
Affiliation(s)
- Prasenjit Dey
- Department of Mechanical Engineering, National Institute of Technology Goa, Ponda, Goa 403401, India
| | - Sandip K. Saha
- Department of Mechanical Engineering, Indian Institute of Technology Bombay, Mumbai 400076, India
| | - Sandip Sarkar
- Department of Mechanical Engineering, Jadavpur University, Kolkata 700032, India
| |
Collapse
|
17
|
Pant CS, Kumar S, Gavasane A. Mixing at the interface of the sneezing/coughing phenomena and its effect on viral loading. PHYSICS OF FLUIDS (WOODBURY, N.Y. : 1994) 2021; 33:115129. [PMID: 35002200 PMCID: PMC8728636 DOI: 10.1063/5.0073563] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/01/2021] [Accepted: 10/31/2021] [Indexed: 06/14/2023]
Abstract
The primary objective of this work is to investigate the mixing of droplets/aerosols, which originates from the sneezing/coughing (of possibly COVID-19 patient) with the ambient atmosphere. Effectively, we are studying the growth/decay of droplets/aerosols in the presence of inhomogeneous mixing, which focuses on the phenomena of entrainment of the (relatively) dry ambient air. We have varied the initial standard deviation, mean radius of the droplets/aerosols size distribution, and humidity of the ambient atmosphere to understand their effects on the final size spectra of droplets. Furthermore, a rigorous error analysis is carried out to understand the relative importance of these effects on the final spectra of droplets/aerosols. We find that these are vital parameters to determine the final spectra of droplets, which govern the broadening of the size spectra. Typically, broadening the size spectra of droplets/aerosols increases the probability of the virus-laden droplets/aerosols and thus could affect the transmission of infection in the ambient atmosphere.
Collapse
Affiliation(s)
- Chandra Shekhar Pant
- Faculty of Mechanical Engineering, Technion-Israel Institute of Technology, Haifa, Israel
| | - Sumit Kumar
- Department of Mechanical Engineering, National Institute of Technology, Rourkela, India
| | - Abhimanyu Gavasane
- Department of Mechanical Engineering, B.M.S. College of Engineering, Bengaluru, India
| |
Collapse
|
18
|
Peng NN, Chow KW, Liu CH. Computational study on the transmission of the SARS-CoV-2 virus through aerosol in an elevator cabin: Effect of the ventilation system. PHYSICS OF FLUIDS (WOODBURY, N.Y. : 1994) 2021; 33:103325. [PMID: 34737531 PMCID: PMC8561651 DOI: 10.1063/5.0068244] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/24/2021] [Accepted: 10/06/2021] [Indexed: 05/02/2023]
Abstract
Aerosol transmission is now well-established as a route in the spread of the SARS-CoV-2 virus. Factors influencing the transport of virus-laden particles in an elevator cabin are investigated computationally and include human respiratory events, locations of the infected person(s), and the ventilation system (ventilation mode, ventilation capacity, and vent schemes). "Breath," "cough," and "sneeze" are defined quantitatively by the fluid jet velocities and particle sizes. For natural ventilation, most particles exhaled by sneezing and coughing tend to deposit on surfaces quickly, but aerosol generated by breathing will remain suspended in the air longer. For forced ventilation, motions of particles under different ventilation capacities are compared. Larger particles otherwise deposited readily on solid surfaces may be slowed down by airflow. Air currents also accelerate the motions of smaller particles, facilitating the subsequent deposition of micrometer or sub-micrometer particles. Locations of the infected person(s) lead to different spreading scenarios due to the distinctive motions of the particles generated by the various respiratory events. Sneeze particles will likely contaminate the person in front of the infected passenger only. Cough particles will increase the risk of all the people around the injector. Breath particles tend to spread throughout the confined environment. An optimized vent scheme is introduced and can reduce particles suspended in the air by up to 80% as compared with commonly used schemes. The purification function of this vent model is robust to various positions of the infected passenger.
Collapse
Affiliation(s)
| | | | - C. H. Liu
- Author to whom correspondence should be addressed:. Tel.: (852) 3917 7901. Fax: (852) 2858 5415
| |
Collapse
|
19
|
Sen N, Singh KK. Spread of virus laden aerosols inside a moving sports utility vehicle with open windows: A numerical study. PHYSICS OF FLUIDS (WOODBURY, N.Y. : 1994) 2021; 33:095117. [PMID: 34588759 PMCID: PMC8474020 DOI: 10.1063/5.0061753] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/29/2021] [Accepted: 08/04/2021] [Indexed: 05/06/2023]
Abstract
A three dimensional Computational Fluid Dynamics (CFD) model to study the dispersion of virus laden aerosols in a car moving with its windows open is reported. The aerosols are generated when a possibly infected passenger speaks. A sports utility vehicle having three rows of seats has been considered. As the vehicle moves forward, its interior will exchange air from the surroundings. The CFD model captures the flow patterns generated both outside and inside the vehicle. This internal aerodynamics will in turn dictate how aerosols will spread across the interior and whether or not they will be transported outside the vehicle. A Lagrangian approach is used to determine the transport of the aerosol particles and the effect of particle size on the simulation result has been studied. Four sets of scenarios of practical interest have been considered. The first set shows the effect of vehicle speed on aerosol transport, and the second set describes what happens when some of the windows are closed, while the third set describes how aerosol transport is affected by the location of the passenger speaking. The fourth set describes how a gush of cross wind affects aerosol transport. Simulation results reveal that when all windows are open, aerosols can go out of one window and then return back to the vehicle interior through another window. Results also reveal that when a passenger sitting in the second row speaks, the aerosols generated span across the entire volume of the car interior before going out through the open windows.
Collapse
Affiliation(s)
- Nirvik Sen
- Chemical Engineering Division, Bhabha Atomic Research Centre, Trombay, Mumbai 400085, India
| | - K. K. Singh
- Authors to whom correspondence should be addressed: and
| |
Collapse
|
20
|
Peña-Monferrer C, Antao S, Manson-Sawko R. Numerical investigation of respiratory drops dynamics released during vocalization. PHYSICS OF FLUIDS (WOODBURY, N.Y. : 1994) 2021; 33:083321. [PMID: 34471339 PMCID: PMC8404381 DOI: 10.1063/5.0059419] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/09/2021] [Accepted: 08/01/2021] [Indexed: 05/14/2023]
Abstract
Release of drops from a human body has been the focus of many recent investigations because of the current COVID-19 pandemic. Indirect virus transmission from asymptomatic individuals has been proved to be one of the major infectious routes and difficult to quantify, detect, and mitigate. We show in this work a detailed and novel numerical investigation of drops released during vocalization from a thermal manikin using a large eddy simulation coupled with Lagrangian tracking of drops. The vocalization experiment was modeled using existing data from the literature for modeling exhaled airflow, emission rate, and size distribution. Particular focus was on the definition of the boundary conditions for the exhalation process. Turbulence was compared with experimental data for the near mouth region for 75 exhalation breathing cycles and showed the sensitivity of different modeling assumptions at the mouth inlet. The results provide insights of special interest for understanding drop dynamics in speech-like exhalation modes, modeling the mouth inlet boundary conditions, and providing data for verifying other more simplified models.
Collapse
Affiliation(s)
- C. Peña-Monferrer
- IBM Research Europe, The Hartree Centre, Warrington WA4 4Ad, United Kingdom
| | | | | |
Collapse
|
21
|
Katre P, Banerjee S, Balusamy S, Sahu KC. Fluid dynamics of respiratory droplets in the context of COVID-19: Airborne and surfaceborne transmissions. PHYSICS OF FLUIDS (WOODBURY, N.Y. : 1994) 2021; 33:081302. [PMID: 34471333 PMCID: PMC8404377 DOI: 10.1063/5.0063475] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/15/2021] [Accepted: 08/03/2021] [Indexed: 05/19/2023]
Abstract
The World Health Organization has declared COVID-19 a global pandemic. Several countries have experienced repeated periods of major spreading over the last two years. Many people have lost their lives, employment, and the socioeconomic situation has been severely impacted. Thus, it is considered to be one of the major health and economic disasters in modern history. Over the last two years, several researchers have contributed significantly to the study of droplet formation, transmission, and lifetime in the context of understanding the spread of such respiratory infections from a fluid dynamics perspective. The current review emphasizes the numerous ways in which fluid dynamics aids in the comprehension of these aspects. The biology of the virus, as well as other statistical studies to forecast the pandemic, is significant, but they are not included in this review.
Collapse
Affiliation(s)
- Pallavi Katre
- Department of Chemical Engineering, Indian Institute of Technology Hyderabad, Sangareddy 502285, Telangana, India
| | - Sayak Banerjee
- Department of Mechanical and Aerospace Engineering, Indian Institute of Technology Hyderabad, Sangareddy 502285, Telangana, India
| | - Saravanan Balusamy
- Department of Mechanical and Aerospace Engineering, Indian Institute of Technology Hyderabad, Sangareddy 502285, Telangana, India
| | - Kirti Chandra Sahu
- Department of Chemical Engineering, Indian Institute of Technology Hyderabad, Sangareddy 502285, Telangana, India
| |
Collapse
|
22
|
Abstract
The protection provided by wearing masks has been a guideline worldwide to prevent the risk of COVID-19 infection. The current work presents an investigation that analyzes the effectiveness of face shields as personal protective equipment. To that end, a multiphase computational fluid dynamic study based on Eulerian–Lagrangian techniques was defined to simulate the spread of the droplets produced by a sneeze. Different scenarios were evaluated where the relative humidity, ambient temperature, evaporation, mass transfer, break up, and turbulent dispersion were taken into account. The saliva that the human body generates was modeled as a saline solution of 8.8 g per 100 mL. In addition, the influence of the wind speed was studied with a soft breeze of 7 km/h and a moderate wind of 14 km/h. The results indicate that the face shield does not provide accurate protection, because only the person who is sneezed on is protected. Moreover, with a wind of 14 km/h, none of the droplets exhaled into the environment hit the face shield, instead, they were deposited onto the neck and face of the wearer. In the presence of an airflow, the droplets exhaled into the environment exceeded the safe distance marked by the WHO. Relative humidity and ambient temperature play an important role in the lifetime of the droplets.
Collapse
|