1
|
Yang GH, Lin J, Cheung H, Rui G, Zhao Y, Balachander L, Joo T, Lee H, Smith ZP, Zhu L, Ma C, Fink Y. Single Layer Silk and Cotton Woven Fabrics for Acoustic Emission and Active Sound Suppression. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2024; 36:e2313328. [PMID: 38561634 DOI: 10.1002/adma.202313328] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/07/2023] [Revised: 03/28/2024] [Indexed: 04/04/2024]
Abstract
Whether intentionally generating acoustic waves or attempting to mitigate unwanted noise, sound control is an area of challenge and opportunity. This study investigates traditional fabrics as emitters and suppressors of sound. When attached to a single strand of a piezoelectric fiber actuator, a silk fabric emits up to 70 dB of sound. Despite the complex fabric structure, vibrometer measurements reveal behavior reminiscent of a classical thin plate. Fabric pore size relative to the viscous boundary layer thickness is found-through comparative fabric analysis-to influence acoustic-emission efficiency. Sound suppression is demonstrated using two distinct mechanisms. In the first, direct acoustic interference is shown to reduce sound by up to 37 dB. The second relies on pacifying the fabric vibrations by the piezoelectric fiber, reducing the amplitude of vibration waves by 95% and attenuating the transmitted sound by up to 75%. Interestingly, this vibration-mediated suppression in principle reduces sound in an unlimited volume. It also allows the acoustic reflectivity of the fabric to be dynamically controlled, increasing by up to 68%. The sound emission and suppression efficiency of a 130 µm silk fabric presents opportunities for sound control in a variety of applications ranging from apparel to transportation to architecture.
Collapse
Affiliation(s)
- Grace H Yang
- Department of Chemical Engineering, Massachusetts Institute of Technology (MIT), Cambridge, MA, 02139, USA
| | - Jinuan Lin
- Department of Electrical and Computer Engineering, University of Wisconsin-Madison, Madison, WI, 53706, USA
| | - Henry Cheung
- Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA
| | - Guanchun Rui
- Department of Macromolecular Science and Engineering, Case Western Reserve University, Cleveland, OH, 44106, USA
| | - Yongyi Zhao
- Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA
| | - Latika Balachander
- Textiles Department, Rhode Island School of Design, Providence, RI, 02903, USA
| | - Taigyu Joo
- Department of Chemical Engineering, Massachusetts Institute of Technology (MIT), Cambridge, MA, 02139, USA
| | - Hyunhee Lee
- Department of Chemical Engineering, Massachusetts Institute of Technology (MIT), Cambridge, MA, 02139, USA
| | - Zachary P Smith
- Department of Chemical Engineering, Massachusetts Institute of Technology (MIT), Cambridge, MA, 02139, USA
| | - Lei Zhu
- Department of Macromolecular Science and Engineering, Case Western Reserve University, Cleveland, OH, 44106, USA
| | - Chu Ma
- Department of Electrical and Computer Engineering, University of Wisconsin-Madison, Madison, WI, 53706, USA
| | - Yoel Fink
- Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA
- Department of Materials Science and Engineering, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA
- Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA
| |
Collapse
|
2
|
Zhao C. Endoscopic Broad Palisade Cartilage Graft Without Raising a Tympanomeatal Flap in the Repair of Subtotal Perforation. EAR, NOSE & THROAT JOURNAL 2024:1455613241249030. [PMID: 38634317 DOI: 10.1177/01455613241249030] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/19/2024] Open
Abstract
Objective: This study evaluated the outcome of a broad palisade cartilage graft in the repair of subtotal perforation. Study Design: Prospective case series. Materials and Methods: This was a prospective study of 43 patients with subtotal perforations who underwent an endoscopic broad palisade cartilage graft procedure that did not include raising a tympanomeatal flap. The patients were followed up for 6 months. Results: The 43 patients (43 ears) included in this study had a mean operation time of 38.6 ± 7.4 minutes. Five (11.6%) patients were lost to follow-up; 38 (88.4%) completed the 6 month follow-up. The graft success rate in the latter was 92.1% (35/38). Audiological testing showed no sensorineural threshold shift. The mean preoperative air-bone gap (ABG) was 28.4 ± 5.1 dB, while the mean ABG at 6 months postoperatively was 13.6 ± 3.1 dB; the difference between these values was significant (P < .05; paired samples t test). According to the audiometry assessment, the successful surgery rate (postoperative ABG ≤ 20 dB) was 89.5% (34/38). No graft-related complications (eg, graft lateralization, significant blunting, graft medialization) were encountered during the follow-up period. However, granular myringitis with minimal moistness but without infection was noted in 5.3% (2/38) of the patients. Conclusions: In the repair of subtotal perforation, an endoscopic broad palisade cartilage graft, performed without raising a tympanomeatal flap, is simple and feasible, resulting in a high graft success rate and good hearing restoration.
Collapse
Affiliation(s)
- Chaowei Zhao
- Department of Otorhinolaryngology, Wenzhou Medical University Affiliated Yiwu Hospital, Yiwu, Zhejiang, China
| |
Collapse
|
3
|
Nørgaard KM, Motallebzadeh H, Puria S. The influence of tympanic-membrane orientation on acoustic ear-canal quantities: A finite-element analysis. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2024; 155:2769-2785. [PMID: 38662609 PMCID: PMC11052631 DOI: 10.1121/10.0025768] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/13/2023] [Revised: 02/23/2024] [Accepted: 04/01/2024] [Indexed: 04/28/2024]
Abstract
Assuming plane waves, ear-canal acoustic quantities, collectively known as wideband acoustic immittance (WAI), are frequently used in research and in the clinic to assess the conductive status of the middle ear. Secondary applications include compensating for the ear-canal acoustics when delivering stimuli to the ear and measuring otoacoustic emissions. However, the ear canal is inherently non-uniform and terminated at an oblique angle by the conical-shaped tympanic membrane (TM), thus potentially confounding the ability of WAI quantities in characterizing the middle-ear status. This paper studies the isolated possible confounding effects of TM orientation and shape on characterizing the middle ear using WAI in human ears. That is, the non-uniform geometry of the ear canal is not considered except for that resulting from the TM orientation and shape. This is achieved using finite-element models of uniform ear canals terminated by both lumped-element and finite-element middle-ear models. In addition, the effects on stimulation and reverse-transmission quantities are investigated, including the physical significance of quantities seeking to approximate the sound pressure at the TM. The results show a relatively small effect of the TM orientation on WAI quantities, except for a distinct delay above 10 kHz, further affecting some stimulation and reverse-transmission quantities.
Collapse
Affiliation(s)
- Kren Monrad Nørgaard
- Interacoustics Research Unit, 2800 Kongens Lyngby, Denmark
- Interacoustics A/S, 5500 Middelfart, Denmark
| | - Hamid Motallebzadeh
- Department of Communication Sciences & Disorders, California State University, Sacramento, California 95819, USA
- Department of Biomedical Engineering, McGill University, Montréal, Quebec H3A 2B4, Canada
| | - Sunil Puria
- Eaton-Peabody Laboratories, Massachusetts Eye and Ear, Boston, Massachusetts 02114, USA
- Department of Otolaryngology, Harvard Medical School, Boston, Massachusetts 02115, USA
- Graduate Program in Speech and Hearing Bioscience and Technology, Harvard University, Cambridge, Massachusetts 02138, USA
| |
Collapse
|
4
|
Lin Z, Duan S, Liu M, Dang C, Qian S, Zhang L, Wang H, Yan W, Zhu M. Insights into Materials, Physics, and Applications in Flexible and Wearable Acoustic Sensing Technology. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2024; 36:e2306880. [PMID: 38015990 DOI: 10.1002/adma.202306880] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/12/2023] [Revised: 11/22/2023] [Indexed: 11/30/2023]
Abstract
Sound plays a crucial role in the perception of the world. It allows to communicate, learn, and detect potential dangers, diagnose diseases, and much more. However, traditional acoustic sensors are limited in their form factors, being rigid and cumbersome, which restricts their potential applications. Recently, acoustic sensors have made significant advancements, transitioning from rudimentary forms to wearable devices and smart everyday clothing that can conform to soft, curved, and deformable surfaces or surroundings. In this review, the latest scientific and technological breakthroughs with insightful analysis in materials, physics, design principles, fabrication strategies, functions, and applications of flexible and wearable acoustic sensing technology are comprehensively explored. The new generation of acoustic sensors that can recognize voice, interact with machines, control robots, enable marine positioning and localization, monitor structural health, diagnose human vital signs in deep tissues, and perform organ imaging is highlighted. These innovations offer unique solutions to significant challenges in fields such as healthcare, biomedicine, wearables, robotics, and metaverse. Finally, the existing challenges and future opportunities in the field are addressed, providing strategies to advance acoustic sensing technologies for intriguing real-world applications and inspire new research directions.
Collapse
Affiliation(s)
- Zhiwei Lin
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, College of Materials Science and Engineering, Donghua University, Shanghai, 201620, China
- School of Electrical and Electronic Engineering, Nanyang Technological University (NTU), Singapore, 639798, Singapore
| | - Shengshun Duan
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, College of Materials Science and Engineering, Donghua University, Shanghai, 201620, China
- School of Electrical and Electronic Engineering, Nanyang Technological University (NTU), Singapore, 639798, Singapore
| | - Mingyang Liu
- School of Electrical and Electronic Engineering, Nanyang Technological University (NTU), Singapore, 639798, Singapore
| | - Chao Dang
- School of Electrical and Electronic Engineering, Nanyang Technological University (NTU), Singapore, 639798, Singapore
| | - Shengtai Qian
- School of Electrical and Electronic Engineering, Nanyang Technological University (NTU), Singapore, 639798, Singapore
| | - Luxue Zhang
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, College of Materials Science and Engineering, Donghua University, Shanghai, 201620, China
| | - Hailiang Wang
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, College of Materials Science and Engineering, Donghua University, Shanghai, 201620, China
| | - Wei Yan
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, College of Materials Science and Engineering, Donghua University, Shanghai, 201620, China
| | - Meifang Zhu
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, College of Materials Science and Engineering, Donghua University, Shanghai, 201620, China
| |
Collapse
|
5
|
Lou Z, Li C, Yu D, Wang J, Chen Z, Yin S. Comparison of healing of acute total tympanic membrane perforation between rats with and without excision of the mallear handle. Laryngoscope Investig Otolaryngol 2023; 8:1648-1656. [PMID: 38130269 PMCID: PMC10731538 DOI: 10.1002/lio2.1175] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2023] [Revised: 09/15/2023] [Accepted: 10/06/2023] [Indexed: 12/23/2023] Open
Abstract
Objective We compared the histological changes and hearing restoration during the healing of acute total tympanic membrane (TM) perforations between Sprague-Dawley (SD) rats with and without excision of the mallear handle. Materials and methods Bilateral, acute, and total TM perforations were created in 36 male SD rats. The mallear handle was preserved in the left ear (handle-preserved ear [HPE]) and excised from the right ear (handle-excised ear [HEE]). Endoscopical examination, auditory brainstem response (ABR) thresholds, histopathological, and scanning electron microscope (SEM) analysis were performed. Results Endoscopic photographs showed that all perforations in the 18 SD rats were closed. The mean closure times were 6.83 ± 0.85 and 8.50 ± 0.71 days in the HPE and HEE groups, respectively (p < .001). SEM images showed radial arrangement of fiber bundles in a single direction in HPEs, although normal arrangement was not achieved. In contrast, HEEs showed disorganized arrangement. At 1 month after perforation closure, the ABR thresholds at high frequencies were significantly higher in the HEE group than in the HPE group (p = .029 and p = .017 for 16 and 32 kHz, respectively). Additionally, the changes in ABR threshold were significantly different at high frequencies (p = .011 and p = .017 for 16 and 32 kHz, respectively) before and 1 month after perforation closure between the HPE and HEE groups, although the differences were not statistically significant at the remaining frequencies. Conclusion Although the malleus handle may not affect the closure of total perforation in SD rats, it contributes to accelerate the perforation closure by possible guide the migration of proliferative epithelial cell on the upper halves of the annulus. Additionally, resection of the malleus handle impairs high frequency hearing recovery following spontaneous closure of the TM.
Collapse
Affiliation(s)
- Zihan Lou
- Department of Otolaryngology‐Head and Neck SurgeryShanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of MedicineShanghaiChina
- Department of Otolaryngology‐Head and Neck Surgery & Center of Sleep MedicineShanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of MedicineShanghaiChina
- Otolaryngological Institute of Shanghai Jiao Tong UniversityShanghaiChina
- Shanghai Key Lab Sleep Disordered BreathingShanghaiChina
| | - Chunyan Li
- Department of Otolaryngology‐Head and Neck SurgeryShanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of MedicineShanghaiChina
- Department of Otolaryngology‐Head and Neck Surgery & Center of Sleep MedicineShanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of MedicineShanghaiChina
- Otolaryngological Institute of Shanghai Jiao Tong UniversityShanghaiChina
- Shanghai Key Lab Sleep Disordered BreathingShanghaiChina
| | - Dongzhen Yu
- Department of Otolaryngology‐Head and Neck SurgeryShanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of MedicineShanghaiChina
- Department of Otolaryngology‐Head and Neck Surgery & Center of Sleep MedicineShanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of MedicineShanghaiChina
- Otolaryngological Institute of Shanghai Jiao Tong UniversityShanghaiChina
- Shanghai Key Lab Sleep Disordered BreathingShanghaiChina
| | - Jingjing Wang
- Department of Otolaryngology‐Head and Neck SurgeryShanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of MedicineShanghaiChina
- Department of Otolaryngology‐Head and Neck Surgery & Center of Sleep MedicineShanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of MedicineShanghaiChina
- Otolaryngological Institute of Shanghai Jiao Tong UniversityShanghaiChina
- Shanghai Key Lab Sleep Disordered BreathingShanghaiChina
| | - Zhengnong Chen
- Department of Otolaryngology‐Head and Neck SurgeryShanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of MedicineShanghaiChina
- Department of Otolaryngology‐Head and Neck Surgery & Center of Sleep MedicineShanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of MedicineShanghaiChina
- Otolaryngological Institute of Shanghai Jiao Tong UniversityShanghaiChina
- Shanghai Key Lab Sleep Disordered BreathingShanghaiChina
| | - Shankai Yin
- Department of Otolaryngology‐Head and Neck SurgeryShanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of MedicineShanghaiChina
- Department of Otolaryngology‐Head and Neck Surgery & Center of Sleep MedicineShanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of MedicineShanghaiChina
- Otolaryngological Institute of Shanghai Jiao Tong UniversityShanghaiChina
- Shanghai Key Lab Sleep Disordered BreathingShanghaiChina
| |
Collapse
|
6
|
Asakura T, Ito R, Hirabayashi M, Kurihara S, Kurashina Y. Mechanical effect of reconstructed shapes of autologous ossicles on middle ear acoustic transmission. Front Bioeng Biotechnol 2023; 11:1204972. [PMID: 37425366 PMCID: PMC10323686 DOI: 10.3389/fbioe.2023.1204972] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2023] [Accepted: 06/12/2023] [Indexed: 07/11/2023] Open
Abstract
Conductive hearing loss is caused by a variety of defects, such as chronic otitis media, osteosclerosis, and malformation of the ossicles. In such cases, the defective bones of the middle ear are often surgically reconstructed using artificial ossicles to increase the hearing ability. However, in some cases, the surgical procedure does not result in increased hearing, especially in a difficult case, for example, when only the footplate of the stapes remains and all of the other bones are destroyed. Herein, the appropriate shapes of the reconstructed autologous ossicles, which are suitable for various types of middle-ear defects, can be determined by adopting an updating calculation based on a method that combines numerical prediction of the vibroacoustic transmission and optimization. In this study, the vibroacoustic transmission characteristics were calculated for bone models of the human middle ear by using the finite element method (FEM), after which Bayesian optimization (BO) was applied. The effect of the shape of artificial autologous ossicles on the acoustic transmission characteristics of the middle ear was investigated with the combined FEM and BO method. The results suggested that the volume of the artificial autologous ossicles especially has a great influence on the numerically obtained hearing levels.
Collapse
Affiliation(s)
- Takumi Asakura
- Department of Mechanical Engineering, Faculty of Science and Engineering, Tokyo University of Science, Chiba, Japan
| | | | - Motoki Hirabayashi
- Department of Otorhinolaryngology, The Jikei University School of Medicine, Tokyo, Japan
- Division of Regenerative Medicine, The Jikei University School of Medicine, Tokyo, Japan
| | - Sho Kurihara
- Department of Otorhinolaryngology, The Jikei University School of Medicine, Tokyo, Japan
- Division of Regenerative Medicine, The Jikei University School of Medicine, Tokyo, Japan
| | - Yuta Kurashina
- Division of Advanced Mechanical Systems Engineering, Institute of Engineering, Tokyo University of Agriculture and Technology, Tokyo, Japan
| |
Collapse
|
7
|
Capshaw G, Brown AD, Peña JL, Carr CE, Christensen-Dalsgaard J, Tollin DJ, Womack MC, McCullagh EA. The continued importance of comparative auditory research to modern scientific discovery. Hear Res 2023; 433:108766. [PMID: 37084504 PMCID: PMC10321136 DOI: 10.1016/j.heares.2023.108766] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/01/2022] [Revised: 03/23/2023] [Accepted: 04/05/2023] [Indexed: 04/23/2023]
Abstract
A rich history of comparative research in the auditory field has afforded a synthetic view of sound information processing by ears and brains. Some organisms have proven to be powerful models for human hearing due to fundamental similarities (e.g., well-matched hearing ranges), while others feature intriguing differences (e.g., atympanic ears) that invite further study. Work across diverse "non-traditional" organisms, from small mammals to avians to amphibians and beyond, continues to propel auditory science forward, netting a variety of biomedical and technological advances along the way. In this brief review, limited primarily to tetrapod vertebrates, we discuss the continued importance of comparative studies in hearing research from the periphery to central nervous system with a focus on outstanding questions such as mechanisms for sound capture, peripheral and central processing of directional/spatial information, and non-canonical auditory processing, including efferent and hormonal effects.
Collapse
Affiliation(s)
- Grace Capshaw
- Department of Psychological and Brain Sciences, Johns Hopkins University, Baltimore, MD 21218, USA.
| | - Andrew D Brown
- Department of Speech and Hearing Sciences, University of Washington, Seattle, WA 98105, USA
| | - José L Peña
- Dominick P. Purpura Department of Neuroscience, Albert Einstein College of Medicine, Bronx, NY 10461, USA
| | - Catherine E Carr
- Department of Biology, University of Maryland, College Park, MD 20742, USA
| | | | - Daniel J Tollin
- Department of Physiology and Biophysics, University of Colorado Anschutz Medical Campus, Aurora, CO 80045, USA; Department of Otolaryngology, University of Colorado Anschutz Medical Campus, Aurora, CO 80045, USA
| | - Molly C Womack
- Department of Biology, Utah State University, Logan, UT 84322, USA.
| | - Elizabeth A McCullagh
- Department of Integrative Biology, Oklahoma State University, Stillwater, OK 74078, USA.
| |
Collapse
|
8
|
Human middle-ear muscle pulls change tympanic-membrane shape and low-frequency middle-ear transmission magnitudes and delays. Hear Res 2023; 430:108721. [PMID: 36821982 DOI: 10.1016/j.heares.2023.108721] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/05/2022] [Revised: 01/27/2023] [Accepted: 02/09/2023] [Indexed: 02/13/2023]
Abstract
The three-bone flexible ossicular chain in mammals may allow independent alterations of middle-ear (ME) sound transmission via its two attached muscles, for both acoustic and non-acoustic stimuli. The tensor tympani (TT) muscle, which has its insertion on the malleus neck, is thought to increase tension of the tympanic membrane (TM). The stapedius (St) muscle, which has its insertion on the stapes posterior crus, is known to stiffen the stapes annular ligament. We produced ME changes in human cadaveric temporal bones by statically pulling on the TT and St muscles. The 3D static TM shape and sound-induced umbo motions from 20 Hz to 10 kHz were measured with optical coherence tomography (OCT); stapes motion was measured using laser-Doppler vibrometry (LDV). TT pulls made the TM shape more conical and moved the umbo medially, while St pulls moved the umbo laterally. In response to sound below about 1 kHz, stapes-velocity magnitudes generally decreased by about 10 dB due to TT pulls and 5 dB due to St pulls. In the 250 to 500 Hz region, the group delay calculated from stapes-velocity phase showed a decrease in transmission delay of about 150 µs by TT pulls and 60 µs by St pulls. Our interpretation of these results is that ME-muscle activity may provide a way of mechanically changing interaural time- and level-difference cues. These effects could help the brain align head-centered auditory and ocular-centered visual representations of the environment.
Collapse
|
9
|
Shi H, Xiang S, Wang L, Sun Y, Wang J, Liu Z. Characterization of middle ear soft tissue damping and its role in sound transmission. Biomech Model Mechanobiol 2023; 22:1003-1018. [PMID: 36881185 DOI: 10.1007/s10237-023-01696-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2022] [Accepted: 01/22/2023] [Indexed: 03/08/2023]
Abstract
Damping plays an important role in the middle ear (ME) sound transmission system. However, how to mechanically characterize the damping of ME soft tissues and the role of damping in ME sound transmission have not yet reached a consensus. In this paper, a finite element (FE) model of the partial external and ME of the human ear, considering both Rayleigh damping and viscoelastic damping for different soft tissues, is developed to quantitatively investigate the damping in soft tissues effects on the wide-frequency response of the ME sound transmission system. The model-derived results can capture the high-frequency (above 2 kHz) fluctuations and obtain the 0.9 kHz resonant frequency (RF) of the stapes velocity transfer function (SVTF) response. The results show that the damping of pars tensa (PT), stapedial annular ligament (SAL) and incudostapedial joints (ISJ) can help smooth the broadband response of the umbo and stapes footplate (SFP). It is found that, between 1 and 8 kHz, the damping of the PT increases the magnitude and phase delay of the SVTF above 2 kHz while the damping of the ISJ can avoid excessive phase delay of the SVTF, which is important in maintaining the synchronization in high-frequency vibration but has not been revealed before. Below 1 kHz, the damping of the SAL plays a more important role, and it can decrease the magnitude but increases the phase delay of the SVTF. This study has implications for a better understanding of the mechanism of ME sound transmission.
Collapse
Affiliation(s)
- Huibin Shi
- School of Aerospace Engineering, Tsinghua University, Beijing, 100084, People's Republic of China
| | - Shuyi Xiang
- School of Aerospace Engineering, Tsinghua University, Beijing, 100084, People's Republic of China
| | - Liang Wang
- Department of Mechanics and Tianjin Key Laboratory of Nonlinear Dynamics and Control, Tianjin University, Tianjin, 300350, People's Republic of China
| | - Yongtao Sun
- Department of Mechanics and Tianjin Key Laboratory of Nonlinear Dynamics and Control, Tianjin University, Tianjin, 300350, People's Republic of China
| | - Jie Wang
- Department of Otolaryngology Head and Neck Surgery, Beijing Tongren Hospital, Capital Medical University, Beijing, 100730, China.,Beijing Engineering Research Center of Audiological Technology, Beijing, 100730, China
| | - Zhanli Liu
- School of Aerospace Engineering, Tsinghua University, Beijing, 100084, People's Republic of China.
| |
Collapse
|
10
|
Kose O, Funnell WRJ, Daniel SJ. Vibration Measurements of the Gerbil Eardrum Under Quasi-static Pressure Sweeps. J Assoc Res Otolaryngol 2022; 23:739-750. [PMID: 36100816 PMCID: PMC9789261 DOI: 10.1007/s10162-022-00867-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2021] [Accepted: 08/13/2022] [Indexed: 01/06/2023] Open
Abstract
Tympanometry provides an objective measurement of the status of the middle ear. During tympanometry, the ear-canal pressure is varied, while the response of the ear to sound pressure is measured. The effects of the pressure on the mechanics of the middle ear are not well understood. This study is a continuation of our previous work in which the vibration response of the gerbil eardrum was measured in vivo under quasi-static pressure steps. In this study, we delivered a continuous pressure sweep to the middle ear and measured the vibration response at four locations for six gerbils. Vibrations were recorded using a single-point laser Doppler vibrometer and glass-coated reflective beads (diameter ~ 40 µm) at the umbo and on the mid-manubrium, posterior pars tensa and anterior pars tensa.The vibration magnitudes were similar to those in the previous step-wise pressurization experiments. Most gerbils showed repeatability within less than 10 dB for consecutive cycles. As described in the previous study, as the frequency was increased at ambient pressure, the vibration magnitude on the manubrium increased slightly to a broad peak (referred to as R1) and then decreased until a small peak appeared (referred to as R2), followed by multiple peaks and troughs as the magnitude decreased further. The low-frequency vibration magnitude (at 1 kHz) decreased monotonically as the pressure became more negative except for a dip (about 500 Pa wide) that occurred between - 700 and - 1800 Pa. The lowest overall magnitude was recorded in the dip at mid-manubrium. The vibration magnitudes also decreased as the middle-ear pressure was made more positive and were larger than those at negative pressures. R1 was only visible at negative and small positive middle-ear pressures, while R2 was visible for both positive and negative pressures. R2 split into multiple branches after the middle-ear pressure became slightly positive. No magnitude dip was visible for positive middle-ear pressures.The low-frequency vibration magnitudes at negative middle-ear pressures on the pars tensa were higher than those on the manubrium. R1 was not visible for large negative middle-ear pressures on the pars tensa. R2 appeared as a multi-peak feature on the pars tensa as well, and a higher-frequency branch on the posterior pars tensa appeared as a trough on the anterior pars tensa. The magnitude dip was not present on the pars tensa. The largest overall magnitude was recorded at the R2 peak on the posterior pars tensa.The results of this study expand on the findings of the step-wise pressurization experiments and provide further insight into the evolution of the vibration response of the eardrum under quasi-static pressures.
Collapse
Affiliation(s)
- Orhun Kose
- Department of BioMedical Engineering, McGill University, 3775 rue University, Montréal, QC H3A 2B4 Canada
| | - W. Robert J. Funnell
- Department of BioMedical Engineering, McGill University, 3775 rue University, Montréal, QC H3A 2B4 Canada
- Department of Otolaryngology – Head and Neck Surgery, McGill University, Montréal, Canada
- Department of Pediatric Surgery, McGill University, Montréal, Canada
| | - Sam J. Daniel
- Department of Otolaryngology – Head and Neck Surgery, McGill University, Montréal, Canada
- Department of Pediatric Surgery, McGill University, Montréal, Canada
| |
Collapse
|
11
|
Motallebzadeh H, Puria S. Stimulus-frequency otoacoustic emissions and middle-ear pressure gains in a finite-element mouse model. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2022; 152:2769. [PMID: 36456266 PMCID: PMC9643045 DOI: 10.1121/10.0014901] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/14/2021] [Revised: 09/29/2022] [Accepted: 09/29/2022] [Indexed: 06/17/2023]
Abstract
For evoked otoacoustic emissions (OAEs), the stimulus and emission signals traverse the middle ear (ME) in forward and reverse directions, respectively. In this study, a fully coupled three-dimensional finite-element model of the mouse ear canal (EC), ME, and cochlea was used to calculate ME pressure gains, impedances, and reflectances at the EC-entrance and stapes-footplate-cochlear-fluid interfaces. The cochlear model incorporates a series of interdigitated Y-shaped structures sandwiched between the basilar membrane and reticular lamina, each comprised of a Deiters' cell, its phalangeal-process extension, and an outer hair cell (OHC). By introducing random perturbations to the OHC gains, stimulation-frequency otoacoustic emissions (SFOAEs) were generated. Raising the perturbation magnitude from 10% to 80% increased the SFOAE magnitude by up to 24 dB in the 10-30 kHz frequency range. Increasing or decreasing the stiffness of the stapes annular ligament and eardrum by a factor of 8 changed the SFOAEs by up to 30 dB, but the round-trip ME gain as measured could not account for this. A modified round-trip ME gain, with reflections removed at the EC-entrance and stapes-cochlea boundaries, eliminated a ±10 dB discrepancy and allowed ME changes to be quantitatively associated with changes in measured OAEs.
Collapse
Affiliation(s)
- Hamid Motallebzadeh
- Eaton-Peabody Laboratories, Massachusetts Eye and Ear, Boston, Massachusetts 02114, USA
| | - Sunil Puria
- Eaton-Peabody Laboratories, Massachusetts Eye and Ear, Boston, Massachusetts 02114, USA
| |
Collapse
|
12
|
Ugarteburu M, Withnell RH, Cardoso L, Carriero A, Richter CP. Mammalian middle ear mechanics: A review. Front Bioeng Biotechnol 2022; 10:983510. [PMID: 36299283 PMCID: PMC9589510 DOI: 10.3389/fbioe.2022.983510] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2022] [Accepted: 09/20/2022] [Indexed: 11/13/2022] Open
Abstract
The middle ear is part of the ear in all terrestrial vertebrates. It provides an interface between two media, air and fluid. How does it work? In mammals, the middle ear is traditionally described as increasing gain due to Helmholtz's hydraulic analogy and the lever action of the malleus-incus complex: in effect, an impedance transformer. The conical shape of the eardrum and a frequency-dependent synovial joint function for the ossicles suggest a greater complexity of function than the traditional view. Here we review acoustico-mechanical measurements of middle ear function and the development of middle ear models based on these measurements. We observe that an impedance-matching mechanism (reducing reflection) rather than an impedance transformer (providing gain) best explains experimental findings. We conclude by considering some outstanding questions about middle ear function, recognizing that we are still learning how the middle ear works.
Collapse
Affiliation(s)
- Maialen Ugarteburu
- Department of Biomedical Engineering, The City College of New York, New York, NY, United States
| | - Robert H. Withnell
- Department of Speech, Language and Hearing Sciences, Indiana University, Bloomington, IN, United States
| | - Luis Cardoso
- Department of Biomedical Engineering, The City College of New York, New York, NY, United States
| | - Alessandra Carriero
- Department of Biomedical Engineering, The City College of New York, New York, NY, United States
| | - Claus-Peter Richter
- Department of Otolaryngology, Northwestern University Feinberg School of Medicine, Chicago, IL, United States
- Department of Biomedical Engineering, Northwestern University, Chicago, IL, United States
- Department of Communication Sciences and Disorders, Northwestern University, Chicago, IL, United States
- The Hugh Knowles Center, Northwestern University, Chicago, IL, United States
| |
Collapse
|
13
|
Li C, Xiong Z, Zhou L, Huang W, He Y, Li L, Shi H, Lu J, Wang J, Li D, Yin S. Interfacing Perforated Eardrums with Graphene-Based Membranes for Broadband Hearing Recovery. Adv Healthc Mater 2022; 11:e2201471. [PMID: 35899802 DOI: 10.1002/adhm.202201471] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2022] [Indexed: 01/28/2023]
Abstract
Eardrum perforation and associated hearing loss is a global health problem. Grafting perforated eardrum with autologous tissues in clinic can restore low-frequency hearing but often leaves poor recovery of high-frequency hearing. In this study, the potential of incorporating a thin multilayered graphene membrane (MGM) into the eardrum for broadband hearing recovery in rats is examined. The MGM shows good biocompatibility and biostability to promote the growth of eardrum cells in a regulated manner with little sign of tissue rejection and inflammatory response. After three weeks of implantation, the MGM is found to be encapsulated by a thin layer of newly grown tissue on both sides without a significant folded overgrowth that is often seen in natural healing. The perforation is well sealed, and broadband hearing recovery (1-32 kHz) is enabled and maintained for at least 2 months. Mechanical simulations show that the high elastic modulus of MGM and thin thickness of the reconstructed eardrum play a critical role in the recovery of high-frequency hearing. This work demonstrates the promise of the use of MGM as a functional graft for perforated eardrum to recover hearing in the broadband frequency region and suggests a new acoustics-related medical application for graphene-related 2D materials.
Collapse
Affiliation(s)
- Chunyan Li
- Department of Otorhinolaryngology, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai, 200233, China
| | - Zhiyuan Xiong
- Department of Chemical Engineering, The University of Melbourne, Melbourne, Victoria, 3010, Australia
| | - Lei Zhou
- Department of Otorhinolaryngology-Head and Neck Surgery, Zhongshan Hospital affiliated to Fudan University, Shanghai, 200032, China
| | | | - Yushi He
- Shanghai Electrochemical Energy Devices Research Center, School of Chemistry and Chemical Engineering, Shanghai Jiao Tong University, Shanghai, 200240, China
| | - Linpeng Li
- Department of Otorhinolaryngology, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai, 200233, China
| | - Haibo Shi
- Department of Otorhinolaryngology, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai, 200233, China
| | - Jiayu Lu
- Department of Stomatology, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai, 200233, China
| | - Jian Wang
- School of Communication Science and Disorders, Dalhousie University, Halifax, B3J 1Y6, Canada
| | - Dan Li
- Department of Chemical Engineering, The University of Melbourne, Melbourne, Victoria, 3010, Australia
| | - Shankai Yin
- Department of Otorhinolaryngology, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai, 200233, China
| |
Collapse
|
14
|
Liu Y, Wu C, Chen T, Shen Q, Xiong Y, Chen Z, Li C. Evaluation of acoustic changes in and the healing outcomes of rat eardrums with pars tensa and pars flaccida perforations. Laryngoscope Investig Otolaryngol 2022; 7:816-824. [PMID: 35734049 PMCID: PMC9194967 DOI: 10.1002/lio2.797] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2022] [Revised: 03/11/2022] [Accepted: 04/09/2022] [Indexed: 11/27/2022] Open
Abstract
Objectives To systematically explore the differences in acoustic changes and healing outcomes of tympanic membranes (TMs) with pars flaccida perforation (PFP) and pars tensa perforation (PTP). Methods We created PFPs and PTPs of various sizes in Sprague-Dawley rats, and evaluated TM umbo velocity and hearing function using laser Doppler vibrometry and auditory brainstem response (ABR) measurement before and immediately after perforation. Two weeks later, hearing was reevaluated and TMs were investigated by immunohistochemical staining. Results Small PFPs and PTPs did not significantly affect umbo velocity and hearing function. Large PFPs increased umbo velocity loss at low frequency (1.5 kHz) and elevated ABR thresholds within 1-2 kHz. Large PTP caused significant velocity loss at low frequencies from 1.5 to 3.5 kHz and threshold elevations at full frequencies (1-2 kHz). Two weeks after the perforation, the hearing function of rats with healed PFPs recovered completely. However, high-frequency hearing loss (16-32 kHz) persisted in rats with healed PTPs. Morphological staining revealed that no increase in the thickness and obvious increase in collagen I level of regenerated par flaccida; regenerated pars tensa exhibited obvious increase in thickness and increased collagen I, while the collagen II regeneration was limited with discontinuous and disordered structure in regenerated pars tensa. Conclusion The hearing loss caused by large PFP limits at low frequencies while large PTP can lead to hearing loss at wide range frequencies. PFP and PTP have different functional outcomes after spontaneous healing, which is determined by the discrepant structure reconstruction and collagen regeneration.
Collapse
Affiliation(s)
- Yaoqian Liu
- Otolaryngology Research InstituteShanghai Jiao Tong University Affiliated Sixth People's HospitalShanghaiChina
| | - Cuiping Wu
- Otolaryngology Research InstituteShanghai Jiao Tong University Affiliated Sixth People's HospitalShanghaiChina
| | - Tingting Chen
- Department of Hearing and Language RehabilitationZhejiang Chinese Medicine UniversityHangzhouChina
| | - Qiyue Shen
- Department of Hearing and Language RehabilitationShanghai University of Traditional Chinese MedicineShanghaiChina
| | - Yuanping Xiong
- Department of Otolaryngology Head and Neck SurgeryFirst Affiliated Hospital of Nanchang UniversityNanchangChina
| | - Zhengnong Chen
- Otolaryngology Research InstituteShanghai Jiao Tong University Affiliated Sixth People's HospitalShanghaiChina
- Department of Otolaryngology‐Head and Neck SurgeryShanghai Jiao Tong University Affiliated Sixth People's HospitalShanghaiChina
| | - Chunyan Li
- Otolaryngology Research InstituteShanghai Jiao Tong University Affiliated Sixth People's HospitalShanghaiChina
- Department of Otolaryngology‐Head and Neck SurgeryShanghai Jiao Tong University Affiliated Sixth People's HospitalShanghaiChina
| |
Collapse
|
15
|
ABSTRACTS (BY NUMBER). Tissue Eng Part A 2022. [DOI: 10.1089/ten.tea.2022.29025.abstracts] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022] Open
|
16
|
Hussain Z, Ding P, Zhang L, Zhang Y, Ullah S, Liu Y, Ullah I, Wang Z, Zheng P, Pei R. Multifaceted tannin crosslinked bioinspired dECM decorated nanofibers modulating cell-scaffold biointerface for tympanic membrane perforation bioengineering. Biomed Mater 2022; 17. [PMID: 35334475 DOI: 10.1088/1748-605x/ac6125] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2021] [Accepted: 03/25/2022] [Indexed: 11/12/2022]
Abstract
Tympanic membrane (TM) perforation leads to persistent otitis media, conductive deafness, and affects life quality. Ointment medication may not be sufficient to treat TM perforation due to the lack of an underlying tissue matrix and thus requiring a scaffold-based application. The engineering of scaffold biointerface close to the matrix via tissue-specific decellularized extracellular matrix (dECM) is crucial in instructing cell behaviour and regulating cell-material interaction in the bioengineering domain. Herein, polycaprolactone (PCL) and TM-dECM (from SD rats) were combined in a different ratio in nanofibrous form using an electrospinning process and crosslinked via tannic acid. The histological and biochemical assays demonstrated that chemical and enzymatic decellularization steps removed cellular/immunogenic contents while retaining collagen and glycosaminoglycan. The morphological, physicochemical, thermomechanical, contact angle, and surface chemical studies demonstrated that the tannin crosslinked PCL/dECM nanofibers fine-tune biophysical and biochemical properties. The multifaceted crosslinked nanofibers hold the tunable distribution of dECM moieties, assembled into a spool-shaped membrane, and could easily insert into perforated sites. The dECM decorated fibers provide a preferable biomimetic matrix for L929 fibroblast adhesion, proliferation, matrix adsorption, and f-actin saturation, which could be crucial for bioengineering. Overall, dECM patterning, surface hydrophilicity, interconnected microporosities, and multifaceted nanofibrous biosystem modulate cell-scaffold performance and could open opportunities to reconstruct TM perforation in a biomimetic fashion.
Collapse
Affiliation(s)
- Zahid Hussain
- School of Nano-Tech and Nano-Bionics, University of Science and Technology of China, Hefei, Hefei, Anhui, 230026, CHINA
| | - Pi Ding
- School of Nano-Tech and Nano-Bionics, University of Science and Technology of China, Hefei, Hefei, Anhui, 230026, CHINA
| | - Liwei Zhang
- CAS Key Laboratory for Nano-Bio Interface, Division of Nanobiomedicine, Suzhou Institute of Nano-tech and Nano-Bionics Chinese Academy of Sciences, Suzhou, Suzhou, Jiangsu, 215123, CHINA
| | - Yajie Zhang
- CAS Key Laboratory for Nano-Bio Interface, Division of Nanobiomedicine, Suzhou Institute of Nano-tech and Nano-Bionics Chinese Academy of Sciences, Suzhou, Suzhou, Jiangsu, 215123, CHINA
| | - Salim Ullah
- School of Nano-Tech and Nano-Bionics, University of Science and Technology of China, Hefei, Hefei, Anhui, 230026, CHINA
| | - Yuanshan Liu
- School of Nano-Tech and Nano-Bionics, University of Science and Technology of China, Hefei, Hefei, Anhui, 230026, CHINA
| | - Ismat Ullah
- CAS Key Laboratory for Nano-Bio Interface, Division of Nanobiomedicine, Suzhou Institute of Nano-tech and Nano-Bionics Chinese Academy of Sciences, Suzhou, Suzhou, Jiangsu, 215123, CHINA
| | - Zhili Wang
- CAS Key Laboratory for Nano-Bio Interface, Division of Nanobiomedicine, Suzhou Institute of Nano-tech and Nano-Bionics Chinese Academy of Sciences, Suzhou, Suzhou, Jiangsu, 215123, CHINA
| | - Penghui Zheng
- CAS Key Laboratory for Nano-Bio Interface, Division of Nanobiomedicine, Suzhou Institute of Nano-tech and Nano-Bionics Chinese Academy of Sciences, Suzhou, Suzhou, Jiangsu, 215123, CHINA
| | - Renjun Pei
- CAS Key Laboratory for Nano-Bio Interface, Division of Nanobiomedicine, Suzhou Institute of Nano-tech and Nano-Bionics Chinese Academy of Sciences, Suzhou, Suzhou, Jiangsu, 215123, CHINA
| |
Collapse
|
17
|
Single fibre enables acoustic fabrics via nanometre-scale vibrations. Nature 2022; 603:616-623. [PMID: 35296860 DOI: 10.1038/s41586-022-04476-9] [Citation(s) in RCA: 76] [Impact Index Per Article: 38.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2021] [Accepted: 01/27/2022] [Indexed: 11/08/2022]
Abstract
Fabrics, by virtue of their composition and structure, have traditionally been used as acoustic absorbers1,2. Here, inspired by the auditory system3, we introduce a fabric that operates as a sensitive audible microphone while retaining the traditional qualities of fabrics, such as machine washability and draping. The fabric medium is composed of high-Young's modulus textile yarns in the weft of a cotton warp, converting tenuous 10-7-atmosphere pressure waves at audible frequencies into lower-order mechanical vibration modes. Woven into the fabric is a thermally drawn composite piezoelectric fibre that conforms to the fabric and converts the mechanical vibrations into electrical signals. Key to the fibre sensitivity is an elastomeric cladding that concentrates the mechanical stress in a piezocomposite layer with a high piezoelectric charge coefficient of approximately 46 picocoulombs per newton, a result of the thermal drawing process. Concurrent measurements of electric output and spatial vibration patterns in response to audible acoustic excitation reveal that fabric vibrational modes with nanometre amplitude displacement are the source of the electrical output of the fibre. With the fibre subsuming less than 0.1% of the fabric by volume, a single fibre draw enables tens of square metres of fabric microphone. Three different applications exemplify the usefulness of this study: a woven shirt with dual acoustic fibres measures the precise direction of an acoustic impulse, bidirectional communications are established between two fabrics working as sound emitters and receivers, and a shirt auscultates cardiac sound signals.
Collapse
|
18
|
Wu JP, Yang X, Wang Y, Swift B, Adamson R, Zheng Y, Zhang R, Zhong W, Chen F. High Resolution and Labeling Free Studying the 3D Microstructure of the Pars Tensa-Annulus Unit of Mice. Front Cell Dev Biol 2021; 9:720383. [PMID: 34692679 PMCID: PMC8532514 DOI: 10.3389/fcell.2021.720383] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2021] [Accepted: 08/13/2021] [Indexed: 11/21/2022] Open
Abstract
Hearing loss is a serious illness affecting people’s normal life enormously. The acoustic properties of a tympanic membrane play an important role in hearing, and highly depend on its geometry, composition, microstructure and connection to the surrounding annulus. While the conical geometry of the tympanic membrane is critical to the sound propagation in the auditory system, it presents significant challenges to the study of the 3D microstructure of the tympanic membrane using traditional 2D imaging techniques. To date, most of our knowledge about the 3D microstructure and composition of tympanic membranes is built from 2D microscopic studies, which precludes an accurate understanding of the 3D microstructure, acoustic behaviors and biology of the tissue. Although the tympanic membrane has been reported to contain elastic fibers, the morphological characteristic of the elastic fibers and the spatial arrangement of the elastic fibers with the predominant collagen fibers have not been shown in images. We have developed a 3D imaging technique for the three-dimensional examination of the microstructure of the full thickness of the tympanic membranes in mice without requiring tissue dehydration and stain. We have also used this imaging technique to study the 3D arrangement of the collagen and elastic fibrillar network with the capillaries and cells in the pars tensa-annulus unit at a status close to the native. The most striking findings in the study are the discovery of the 3D form of the elastic and collagen network, and the close spatial relationships between the elastic fibers and the elongated fibroblasts in the tympanic membranes. The 3D imaging technique has enabled to show the 3D waveform contour of the collagen and elastic scaffold in the conical tympanic membrane. Given the close relationship among the acoustic properties, composition, 3D microstructure and geometry of tympanic membranes, the findings may advance the understanding of the structure—acoustic functionality of the tympanic membrane. The knowledge will also be very helpful in the development of advanced cellular therapeutic technologies and 3D printing techniques to restore damaged tympanic membranes to a status close to the native.
Collapse
Affiliation(s)
- Jian-Ping Wu
- Academy of Advanced Interdisciplinary Studies, Southern University of Science and Technology, Shenzhen, China.,Department of Biomedical Engineering, Southern University of Science and Technology, Shenzhen, China
| | - Xiaojie Yang
- Department of Biomedical Engineering, Southern University of Science and Technology, Shenzhen, China
| | - Yilin Wang
- Core Research Facilities, Southern University of Science and Technology, Shenzhen, China
| | - Ben Swift
- College of Computing, Australian National University, Canberra, ACT, Australia
| | - Robert Adamson
- School of Biomedical Engineering, Electrical and Computer Engineering, Dalhousie University, Halifax, NS, Canada
| | - Yongchang Zheng
- Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Rongli Zhang
- Guangdong Provincial People's Hospital, Guangdong Academy of Medical Science, School of Medicine, South China University of Technology, Guangzhou, China
| | - Wen Zhong
- School of Mechanical Engineering and Automation, Xihua University, Chengdu, China
| | - Fangyi Chen
- Department of Biomedical Engineering, Southern University of Science and Technology, Shenzhen, China.,Department of Biology, Brain Research Centre, Southern University of Science and Technology, Shenzhen, China
| |
Collapse
|
19
|
Tang H, Psota P, Rosowski JJ, Furlong C, Cheng JT. Analyses of the Tympanic Membrane Impulse Response Measured with High-Speed Holography. Hear Res 2021; 410:108335. [PMID: 34450569 DOI: 10.1016/j.heares.2021.108335] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/04/2021] [Revised: 08/02/2021] [Accepted: 08/04/2021] [Indexed: 10/20/2022]
Abstract
The Tympanic Membrane (TM) transforms acoustic energy to ossicular vibration. The shape and the displacement of the TM play an important role in this process. We developed a High-speed Digital Holography (HDH) system to measure the shape and transient displacements of the TM induced by acoustic clicks. The displacements were further normalized by the measured shape to derive surface normal displacements at over 100,000 points on the TM surface. Frequency and impulse response analyses were performed at each TM point, which enable us to describe 2D surface maps of four new TM mechanical parameters. From frequency domain analyses, we describe the (i) dominant frequencies of the displacement per sound pressure based on Frequency Response Function (FRF) at each surface point. From time domain analyses, we describe the (ii) rising time, (iii) exponential decay time, and the (iv) root-mean-square (rms) displacement of the TM based on Impulse Response Function (IRF) at each surface point. The resultant 2D maps show that a majority of the TM surface has a dominant frequency of around 1.5 kHz. The rising times suggest that much of the TM surface is set into motion within 50 µs of an impulsive stimulus. The maps of the exponential decay time of the IRF illustrate spatial variations in damping, the least known TM mechanical property. The damping ratios at locations with varied dominant frequencies are quantified and compared.
Collapse
Affiliation(s)
- H Tang
- Center for Holographic Studies and Laser Micro-mechaTronics (CHSLT), Worcester Polytechnic Institute, Worcester, MA United States; Mechanical Engineering Department, Worcester Polytechnic Institute, Worcester, MA United States; Eaton-Peabody Laboratory, Massachusetts Eye and Ear Infirmary, Boston, MA United States.
| | - P Psota
- Faculty of Mechatronics, Informatics and Interdisciplinary Studies, Technical University of Liberec, Liberec, Czech Republic
| | - J J Rosowski
- Eaton-Peabody Laboratory, Massachusetts Eye and Ear Infirmary, Boston, MA United States; Department of Otolaryngology-Head and Neck Surgery, Harvard Medical School, Boston, MA, United States
| | - C Furlong
- Center for Holographic Studies and Laser Micro-mechaTronics (CHSLT), Worcester Polytechnic Institute, Worcester, MA United States; Mechanical Engineering Department, Worcester Polytechnic Institute, Worcester, MA United States; Eaton-Peabody Laboratory, Massachusetts Eye and Ear Infirmary, Boston, MA United States; Department of Otolaryngology-Head and Neck Surgery, Harvard Medical School, Boston, MA, United States
| | - J T Cheng
- Eaton-Peabody Laboratory, Massachusetts Eye and Ear Infirmary, Boston, MA United States; Department of Otolaryngology-Head and Neck Surgery, Harvard Medical School, Boston, MA, United States
| |
Collapse
|
20
|
Torrecilla SG, Avan P. Wideband tympanometry patterns in relation to intracranial pressure. Hear Res 2021; 408:108312. [PMID: 34298416 DOI: 10.1016/j.heares.2021.108312] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/18/2021] [Revised: 06/19/2021] [Accepted: 07/08/2021] [Indexed: 10/20/2022]
Abstract
Wideband tympanometry performs a more thorough analysis of middle-ear mechanics than the conventional single-frequency method with a 226-Hz probe tone. The present work examines the sensitivity of wideband tympanometry to the stiffness of the stapes-annular ligament system in relation to intracranial pressure (ICP) and labyrinthine fluid pressure. Here, body tilt allowed ICP to be set at different values. Sixty-eight ears of volunteers were tested sequentially in upright, supine, head-down (-30°) and upright postures. Energy absorbance of the ear was measured in these postures with a commercially available wideband-tympanometry device between 0.25 and 3 kHz, at ear-canal pressures between -600 and 300 daPa. In each posture, it was possible to find a single (posture-dependent) pressure in the ear canal at which a tympanometric peak occurred at all frequencies below about 1.1 kHz. The average across ears of tympanometric-peak pressure (TPP), close to 0 in upright posture, got increasingly positive, +19 daPa in supine and +27 daPa in head-down positions. The three-dimensional plot of energy absorbance against frequency and pressure displayed an invariant shape, merely shifting with TPP along the pressure axis. Thus, a properly adjusted ear-canal pressure neutralized the effects of ICP on the ear's energy absorbance. Comparisons to published invasive assessments of ICP in the different tested body positions led to the proposed relationship ICP ≈ 15 TPP, likely describing the transformer effect between tympanic membrane and stapes-annular ligament system at quasi-static pressures. With wideband tympanometry, the middle ear may serve as a precision scales for noninvasive ICP measurements.
Collapse
Affiliation(s)
| | - Paul Avan
- Neurosensory Biophysics Laboratory, University Clermont Auvergne, France; Institut de l'Audition, Paris, France; Centre Jean Perrin, Clermont-Ferrand, France.
| |
Collapse
|
21
|
Azimi B, Milazzo M, Danti S. Cellulose-Based Fibrous Materials From Bacteria to Repair Tympanic Membrane Perforations. Front Bioeng Biotechnol 2021; 9:669863. [PMID: 34164386 PMCID: PMC8215662 DOI: 10.3389/fbioe.2021.669863] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2021] [Accepted: 05/13/2021] [Indexed: 12/19/2022] Open
Abstract
Perforation is the most common illness of the tympanic membrane (TM), which is commonly treated with surgical procedures. The success rate of the treatment could be improved by novel bioengineering approaches. In fact, a successful restoration of a damaged TM needs a supporting biomaterial or scaffold able to meet mechano-acoustic properties similar to those of the native TM, along with optimal biocompatibility. Traditionally, a large number of biological-based materials, including paper, silk, Gelfoam®, hyaluronic acid, collagen, and chitosan, have been used for TM repair. A novel biopolymer with promising features for tissue engineering applications is cellulose. It is a highly biocompatible, mechanically and chemically strong polysaccharide, abundant in the environment, with the ability to promote cellular growth and differentiation. Bacterial cellulose (BC), in particular, is produced by microorganisms as a nanofibrous three-dimensional structure of highly pure cellulose, which has thus become a popular graft material for wound healing due to a number of remarkable properties, such as water retention, elasticity, mechanical strength, thermal stability, and transparency. This review paper provides a comprehensive overview of the current experimental studies of BC, focusing on the application of BC patches in the treatment of TM perforations. In addition, computational approaches to model cellulose and TM are summarized, with the aim to synergize the available tools toward the best design and exploitation of BC patches and scaffolds for TM repair and regeneration.
Collapse
Affiliation(s)
- Bahareh Azimi
- Department of Civil and Environmental Engineering, Massachusetts Institute of Technology, Cambridge, MA, United States
- Department of Civil and Industrial Engineering, University of Pisa, Pisa, Italy
- National Interuniversity Consortium of Materials Science and Technology (INSTM), Florence, Italy
| | - Mario Milazzo
- Department of Civil and Environmental Engineering, Massachusetts Institute of Technology, Cambridge, MA, United States
- National Interuniversity Consortium of Materials Science and Technology (INSTM), Florence, Italy
| | - Serena Danti
- Department of Civil and Environmental Engineering, Massachusetts Institute of Technology, Cambridge, MA, United States
- Department of Civil and Industrial Engineering, University of Pisa, Pisa, Italy
- National Interuniversity Consortium of Materials Science and Technology (INSTM), Florence, Italy
| |
Collapse
|
22
|
Gallagher L, Diop M, Olson ES. Time-domain and frequency-domain effects of tensor tympani contraction on middle ear sound transmission in gerbil. Hear Res 2021; 405:108231. [PMID: 33915400 PMCID: PMC8113157 DOI: 10.1016/j.heares.2021.108231] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/12/2021] [Revised: 03/17/2021] [Accepted: 03/20/2021] [Indexed: 11/18/2022]
Abstract
The middle ear is a high-fidelity, broadband impedance transformer that transmits acoustic stimuli at the eardrum to the inner ear. It is home to the two smallest muscles in mammalian species, which modulate middle ear transmission. Of this pair, the function of the tensor tympani muscle (TTM) has remained obscure. We investigated the acoustic effects of this muscle in young adult gerbils. We measured changes in middle ear vibration produced by pulse-train-elicited TTM contraction - in the time-domain with a click stimulus and in the frequency-domain with multitone zwuis stimuli. In our click experiments, there was generally a small reduction in the primary peak of the response and a slight increase in the subsequent ringing, but there was essentially no change in the delay of the click response at the umbo (less than 1 µs change). In our multitone experiments, there were consistent patterns of attenuation and enhancement in the velocity responses at the umbo and ossicles. TTM contraction produced a narrow band of enhancement around 6 kHz (maximally ~5 dB) that can be modeled with an increased stiffness of an overdamped spring-mass resonance. At frequencies below 2 kHz and above 35 kHz, TTM contraction attenuated middle ear vibrations by as much as fivefold.
Collapse
Affiliation(s)
- Liam Gallagher
- OTO/HNS, Columbia University Medical Center, New York, United States
| | - Mohamed Diop
- OTO/HNS, Columbia University Medical Center, New York, United States
| | - Elizabeth S Olson
- OTO/HNS and BME, Columbia University, 630 W 168th street, New York, NY 10032 United States.
| |
Collapse
|
23
|
Milazzo M, David A, Jung GS, Danti S, Buehler MJ. Molecular origin of viscoelasticity in mineralized collagen fibrils. Biomater Sci 2021; 9:3390-3400. [PMID: 33949363 PMCID: PMC8323817 DOI: 10.1039/d0bm02003f] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2020] [Accepted: 03/01/2021] [Indexed: 11/21/2022]
Abstract
Bone is mineralized tissue constituting the skeletal system, supporting and protecting the body's organs and tissues. In addition to such fundamental mechanical functions, bone also plays a remarkable role in sound conduction. From a mechanical standpoint, bone is a composite material consisting of minerals and collagen arranged in multiple hierarchical structures, with a complex anisotropic viscoelastic response, capable of transmitting and dissipating energy. At the molecular level, mineralized collagen fibrils are the basic building blocks of bone tissue, and hence, understanding bone properties down to fundamental tissue structures enables better identification of the mechanisms of structural failures and damage. While efforts have focused on the study of micro- and macro-scale viscoelasticity related to bone damage and healing based on creep, mineralized collagen has not been explored at the molecular level. We report a study that aims at systematically exploring the viscoelasticity of collagenous fibrils with different mineralization levels. We investigate the dynamic mechanical response upon cyclic and impulsive loads to observe the viscoelastic phenomena from either shear or extensional strains via molecular dynamics. We perform a sensitivity analysis with several key benchmarks: intrafibrillar mineralization percentage, hydration state, and external load amplitude. Our results show an increase of the dynamic moduli with an increase of the mineral percentage, pronounced at low strains. When intrafibrillar water is present, the material softens the elastic component, but considerably increases its viscosity, especially at high frequencies. This behavior is confirmed from the material response upon impulsive loads, in which water drastically reduces the relaxation times throughout the input velocity range by one order of magnitude, with respect to the dehydrated counterparts. We find that, upon transient loads, water has a major impact on the mechanics of mineralized fibrillar collagen, being able to improve the capability of the tissue to passively and effectively dissipate energy, especially after fast and high-amplitude external loads. Our study provides knowledge of bone mechanics in relation to pathologies deriving from dehydration or traumas. Moreover, these findings show the potential for being used in designing new bioinspired materials not limited to tissue engineering applications, in which passive mechanisms for dissipating energy can prevent structural failures.
Collapse
Affiliation(s)
- Mario Milazzo
- Laboratory for Atomistic and Molecular Mechanics (LAMM), USA. and The BioRobotics Institute, Scuola Superiore Sant'Anna, Italy
| | - Alessio David
- Dipartimento di Chimica, Materiali e Ingegneria Chimica "G. Natta", Politecnico di Milano, Milano, Italy
| | - Gang Seob Jung
- Laboratory for Atomistic and Molecular Mechanics (LAMM), USA. and Computational Sciences and Engineering Division, Oak Ridge National Laboratory, Oak Ridge, TN 37831, USA
| | - Serena Danti
- Laboratory for Atomistic and Molecular Mechanics (LAMM), USA. and The BioRobotics Institute, Scuola Superiore Sant'Anna, Italy and Department of Civil and Industrial Engineering, University of Pisa, Italy
| | | |
Collapse
|
24
|
Emile J, Emile O, Gaudriault P. Resonant vibration of a thin polymer film under optical excitation. SOFT MATTER 2021; 17:3923-3928. [PMID: 33710231 DOI: 10.1039/d1sm00016k] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
We report on the mechanical excitation of a 220 μm thick thermoplastic film in its amorphous state by the radiation pressure of light. By modulating a low power visible laser (from 100 to 600 mW) at low frequencies (below 100 Hz), we observe a deformation of the film interfaces. The phenomenon, that is independent of the laser wavelength, is amplified at a resonant frequency and reaches 0.68 μm. The deformation is reversible and varies linearly with the optical power. Using the damped oscillator model, we show that the resonant frequency depends on the surface tension of the film. The associated free energy is then compared with the energy lost, taking into account the contribution of the damping corresponding to the imaginary part of the Young's modulus.
Collapse
Affiliation(s)
- Janine Emile
- Université de Rennes 1, CNRS IPR UMR 6251, F-35000 Rennes, France
| | | | | |
Collapse
|
25
|
Cheng JT, Ghanad I, Remenschneider A, Rosowski J. The onset of nonlinear growth of middle-ear responses to high intensity sounds. Hear Res 2021; 405:108242. [PMID: 33872835 DOI: 10.1016/j.heares.2021.108242] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/14/2020] [Revised: 03/20/2021] [Accepted: 03/31/2021] [Indexed: 11/16/2022]
Abstract
The human tympanic membrane (TM) and ossicles are generally considered to act as a linear system as they conduct low and moderate level environmental sounds to the cochlea. At intense stimulus levels (> 120 dB SPL) there is evidence that the TM and ossicles no longer act linearly. The anatomical structures that contribute to the nonlinear responses and their level and frequency dependences are not well defined. We used cadaveric human ears to characterize middle-ear responses to continuous tones between 200 and 20,000 Hz with levels between 60 and 150 dB SPL. The responses of the TM and ossicles are essentially sinusoidal, even at the highest stimulus level, but grow nonlinearly with increased stimulus level. The umbo and the stapes show different nonlinear behaviors: The umbo displacement grows faster than the stimulus level (expansive growth) at frequencies below 2000 Hz, while the stapes exhibits mostly compressive growth (grows slower than the stimulus level) over a wide frequency range. The sound pressure level where the nonlinearity first becomes obvious and the displacement at that level are lower at the stapes than at the umbo. These observations suggest the presence of multiple nonlinear processes within the middle ear. The existence of an expansive growth of umbo displacement that has limited effect on the stapes compressive growth suggests that the ossicular joints reduce the coupling between multiple nonlinear mechanisms within the middle ear. This study provides new data to test and refine middle-ear nonlinear models.
Collapse
Affiliation(s)
- Jeffrey Tao Cheng
- Eaton-Peabody Laboratory, Massachusetts Eye and Ear Infirmary, 243 Charles Street, Boston, MA 02114, United States; Department of Otolaryngology-Head and Neck Surgery, Harvard Medical School, 243 Charles Street, Boston, MA 02114, United States; Graduate Program in Speech and Hearing Bioscience and Technology, Division of Medical Studies, Harvard University, Boston, MA 02115, United States.
| | - Iman Ghanad
- Eaton-Peabody Laboratory, Massachusetts Eye and Ear Infirmary, 243 Charles Street, Boston, MA 02114, United States
| | - Aaron Remenschneider
- Eaton-Peabody Laboratory, Massachusetts Eye and Ear Infirmary, 243 Charles Street, Boston, MA 02114, United States; Department of Otolaryngology-Head and Neck Surgery, Harvard Medical School, 243 Charles Street, Boston, MA 02114, United States; Department of Otolaryngology, UMass Medical Center, 281 Lincoln Street, Worcester, MA 01605, United States
| | - John Rosowski
- Eaton-Peabody Laboratory, Massachusetts Eye and Ear Infirmary, 243 Charles Street, Boston, MA 02114, United States; Department of Otolaryngology-Head and Neck Surgery, Harvard Medical School, 243 Charles Street, Boston, MA 02114, United States; Graduate Program in Speech and Hearing Bioscience and Technology, Division of Medical Studies, Harvard University, Boston, MA 02115, United States
| |
Collapse
|
26
|
Motallebzadeh H, Puria S. Mouse middle-ear forward and reverse acoustics. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2021; 149:2711. [PMID: 33940924 PMCID: PMC8060050 DOI: 10.1121/10.0004218] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/19/2020] [Revised: 03/17/2021] [Accepted: 03/18/2021] [Indexed: 05/26/2023]
Abstract
The mouse is an important animal model for hearing science. However, our knowledge of the relationship between mouse middle-ear (ME) anatomy and function is limited. The ME not only transmits sound to the cochlea in the forward direction, it also transmits otoacoustic emissions generated in the cochlea to the ear canal (EC) in the reverse direction. Due to experimental limitations, a complete characterization of the mouse ME has not been possible. A fully coupled finite-element model of the mouse EC, ME, and cochlea was developed and calibrated against experimental measurements. Impedances of the EC, ME, and cochlea were calculated, alongside pressure transfer functions for the forward, reverse, and round-trip directions. The effects on sound transmission of anatomical changes such as removing the ME cavity, pars flaccida, and mallear orbicular apophysis were also calculated. Surprisingly, below 10 kHz, the ME cavity, eardrum, and stapes annular ligament were found to significantly affect the cochlear input impedance, which is a result of acoustic coupling through the round window. The orbicular apophysis increases the delay of the transmission line formed by the flexible malleus, incus, and stapes, and improves the forward sound-transmission characteristics in the frequency region of 7-30 kHz.
Collapse
Affiliation(s)
- Hamid Motallebzadeh
- Eaton-Peabody Laboratories, Massachusetts Eye and Ear, Boston, Massachusetts 02114, USA
| | - Sunil Puria
- Eaton-Peabody Laboratories, Massachusetts Eye and Ear, Boston, Massachusetts 02114, USA
| |
Collapse
|
27
|
Hussain Z, Pei R. Necessities, opportunities, and challenges for tympanic membrane perforation scaffolding-based bioengineering. Biomed Mater 2021; 16. [PMID: 33260166 DOI: 10.1088/1748-605x/abcf5d] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2020] [Accepted: 12/01/2020] [Indexed: 02/08/2023]
Abstract
Tympanic membrane (TM) perforation is a global clinical dilemma. It occurs as a consequence of object penetration, blast trauma, barotrauma, and middle ear diseases. TM perforation may lead to otitis media, retraction pockets, cholesteatoma, and conductive deafness. Molecular therapies may not be suitable to treat perforation because there is no underlying tissue matrix to support epithelium bridging. Chronic perforations are usually reconstructed with autologous grafts via surgical myringoplasty. Surgical treatment is uncomfortable for the patients. The grafting materials are not perfect because they produce an opaque membrane, fail in up to 20% of cases, and are suboptimal to restore acoustic function. Millions of patients from developing parts of the world have not got access to surgical grafting due to operational complexities, lack of surgical resources, and high cost. These shortcomings emphasize bioengineering to improve placement options, healing rate, hearing outcomes, and minimize surgical procedures. This review highlights cellular, structural, pathophysiological, and perforation specific determinants that affect healing, acoustic and surgical outcomes; and integrates necessities relevant to bioengineered scaffolds. This study further summarizes scaffolding components, progress in scaffolding strategies and design, and engenders limitations and challenges for optimal bioengineering of chronic perforation.
Collapse
Affiliation(s)
- Zahid Hussain
- School of Nano-Tech and Nano-Bionics, University of Science and Technology of China (USTC), Hefei 230026, People's Republic of China
- CAS Key Laboratory for Nano-Bio Interface, Division of Nanobiomedicine, Suzhou Institute of Nano-Tech and Nano-Bionics (SINANO), Chinese Academy of Sciences, Suzhou 215123, People's Republic of China
| | - Renjun Pei
- School of Nano-Tech and Nano-Bionics, University of Science and Technology of China (USTC), Hefei 230026, People's Republic of China
- CAS Key Laboratory for Nano-Bio Interface, Division of Nanobiomedicine, Suzhou Institute of Nano-Tech and Nano-Bionics (SINANO), Chinese Academy of Sciences, Suzhou 215123, People's Republic of China
| |
Collapse
|
28
|
Zhang Y, Wang J, Wang Y, Fu Q, Li Y. Association Between the Air-Bone Gap and Vibration of the Tympanic Membrane After Myringoplasty. EAR, NOSE & THROAT JOURNAL 2021; 100:241-248. [PMID: 33570432 DOI: 10.1177/0145561320983649] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
Air-bone gap (ABG) is an important indicator of hearing status after myringoplasty. A number of factors have been associated with ABG, but some patients still have ABG without identifiable cause. This study aimed to evaluate the relationship between tympanic membrane (TM) vibration using laser Doppler vibrometry (LDV) and ABG after myringoplasty. Between January 2013 and January 2015, 24 patients with ABG of unknown cause after myringoplasty were enrolled at the Beijing Tongren Hospital. Thirty normal controls were recruited from the hospital staff. All patients underwent primary overlay myringoplasty. Pre- and postoperative air conduction (AC) and bone-conduction (BC) thresholds, and ABG were measured. Umbo velocity transfer function (UVTF) for vibration of TM was measured with LDV. Air conduction thresholds were significantly reduced after myringoplasty (all P < .05), while BC thresholds were not significantly changed (all P > .05). ABG was significantly reduced after myringoplasty (all P < .05). Air-bone gap was correlated with UVTF at 1.0 kHz (r = -0.46; P = .024). For patients with UVTF >0.08 mm/s/Pa, ABG was correlated with UVTF (r = -0.56; P = .029). For post-myringoplasty ABG without readily observable causes, there was a significant relationship between ABG and TM vibration. These results provide new insights in the understanding of this relationship and may help explain ABG after myringoplasty when there are no clear contributing factors.
Collapse
Affiliation(s)
- Ying Zhang
- Department of Otolaryngology-Head and Neck Surgery, Beijing Tongren Hospital, 12517Capital Medical University, Beijing, China.,Beijing Engineering Research Center of Hearing Technology, Beijing, China
| | - Jie Wang
- Department of Otolaryngology-Head and Neck Surgery, Beijing Tongren Hospital, 12517Capital Medical University, Beijing, China.,Beijing Engineering Research Center of Hearing Technology, Beijing, China
| | - Yu Wang
- Department of Otolaryngology-Head and Neck Surgery, Eastern Medical District of Chinese PLA General Hospital, Beijing, China
| | - Qianjie Fu
- Department of Head and Neck Surgery, 12222David Geffen School of Medicine, UCLA, Los Angeles, CA, USA
| | - Yongxin Li
- Department of Otolaryngology-Head and Neck Surgery, Beijing Tongren Hospital, 12517Capital Medical University, Beijing, China.,Beijing Engineering Research Center of Hearing Technology, Beijing, China
| |
Collapse
|
29
|
A Hierarchy of Proliferative and Migratory Keratinocytes Maintains the Tympanic Membrane. Cell Stem Cell 2020; 28:315-330.e5. [PMID: 33181078 DOI: 10.1016/j.stem.2020.10.006] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2020] [Revised: 08/30/2020] [Accepted: 10/14/2020] [Indexed: 12/29/2022]
Abstract
The tympanic membrane (TM) is critical for hearing and requires continuous clearing of cellular debris, but little is known about homeostatic mechanisms in the TM epidermis. Using single-cell RNA sequencing, lineage tracing, whole-organ explant, and live-cell imaging, we show that homeostatic TM epidermis is distinct from other epidermal sites and has discrete proliferative zones with a three-dimensional hierarchy of multiple keratinocyte populations. TM stem cells reside in a discrete location of the superior TM and generate long-lived clones and committed progenitors (CPs). CP clones exhibit lateral migration, and their proliferative capacity is supported by Pdgfra+ fibroblasts, generating migratory but non-proliferative progeny. Single-cell sequencing of the human TM revealed similar cell types and transcriptional programming. Thus, during homeostasis, TM keratinocytes transit through a proliferative CP state and exhibit directional lateral migration. This work forms a foundation for understanding TM disorders and modeling keratinocyte biology.
Collapse
|
30
|
A comparative study of avian middle ear mechanics. Hear Res 2020; 395:108043. [DOI: 10.1016/j.heares.2020.108043] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/11/2019] [Revised: 07/02/2020] [Accepted: 07/08/2020] [Indexed: 11/20/2022]
|
31
|
Psota P, Tang H, Pooladvand K, Furlong C, Rosowski JJ, Cheng JT, Lédl V. Multiple angle digital holography for the shape measurement of the unpainted tympanic membrane. OPTICS EXPRESS 2020; 28:24614-24628. [PMID: 32907000 PMCID: PMC7470675 DOI: 10.1364/oe.398919] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/28/2020] [Revised: 07/10/2020] [Accepted: 07/10/2020] [Indexed: 06/11/2023]
Abstract
The shape of the tympanic membrane (TM) plays an important role in sound transmission through the ear for hearing. Previously we developed a high-speed holographic system employing a tunable wavelength laser for rapid TM shape measurement. However, the tunable laser illumination was not sufficient to measure the shape of the unpainted TM due to the semi-transparency of the TM and short exposure time of the camera. This paper presents a new multiple angle illumination technique that allows us to use a higher power single wavelength laser to perform shape measurements on the unpainted TM. Accuracy of the new method is demonstrated by a measure of a step gauge provided by the National Institute of Standards and Technology. We successfully applied the new shape measurement method on a fresh postmortem human TM without any paint.
Collapse
Affiliation(s)
- Pavel Psota
- Faculty of Mechatronics, Informatics and Interdisciplinary Studies, Technical University of Liberec, Liberec 46117, Czech Republic
- TOPTEC, Institute of Plasma Physics of the Czech Academy of Sciences, Turnov 51101, Czech Republic
| | - Haimi Tang
- Center for Holographic Studies and Laser Micro-mechaTronics (CHSLT), Worcester, MA 01609, USA
- Mechanical Engineering Department, Worcester Polytechnic Institute, Worcester, MA 01609, USA
| | - Koohyar Pooladvand
- Center for Holographic Studies and Laser Micro-mechaTronics (CHSLT), Worcester, MA 01609, USA
- Mechanical Engineering Department, Worcester Polytechnic Institute, Worcester, MA 01609, USA
| | - Cosme Furlong
- Center for Holographic Studies and Laser Micro-mechaTronics (CHSLT), Worcester, MA 01609, USA
- Mechanical Engineering Department, Worcester Polytechnic Institute, Worcester, MA 01609, USA
- Eaton-Peabody Laboratory, Massachusetts Eye and Ear Infirmary, Boston, MA 02114, USA
- Department of Otolaryngology-Head and Neck Surgery, Harvard Medical School, Boston, MA 02114, USA
| | - John J. Rosowski
- Eaton-Peabody Laboratory, Massachusetts Eye and Ear Infirmary, Boston, MA 02114, USA
- Department of Otolaryngology-Head and Neck Surgery, Harvard Medical School, Boston, MA 02114, USA
| | - Jeffrey T. Cheng
- Eaton-Peabody Laboratory, Massachusetts Eye and Ear Infirmary, Boston, MA 02114, USA
- Department of Otolaryngology-Head and Neck Surgery, Harvard Medical School, Boston, MA 02114, USA
| | - Vít Lédl
- TOPTEC, Institute of Plasma Physics of the Czech Academy of Sciences, Turnov 51101, Czech Republic
| |
Collapse
|
32
|
Milazzo M, Jung GS, Danti S, Buehler MJ. Mechanics of Mineralized Collagen Fibrils upon Transient Loads. ACS NANO 2020; 14:8307-8316. [PMID: 32603087 DOI: 10.1021/acsnano.0c02180] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Collagen is a key structural protein in the human body, which undergoes mineralization during the formation of hard tissues. Earlier studies have described the mechanical behavior of bone at different scales, highlighting material features across hierarchical structures. Here we present a study that aims to understand the mechanical properties of mineralized collagen fibrils upon tensile/compressive transient loads, investigating how the kinetic energy propagates and it is dissipated at the molecular scale, thus filling a gap of knowledge in this area. These specific features are the mechanisms that nature has developed to passively dissipate stress and prevent structural failures. In addition to the mechanical properties of the mineralized fibrils, we observe distinct nanomechanical behaviors for the two regions (i.e., overlap and gap) of the D-period to highlight the effect of the mineralization. We notice decreasing trends for both wave speeds and Young's moduli over input velocity with a marked strengthening effect in the gap region due to the accumulation of the hydroxyapatite. In contrast, the dissipative behavior is not affected by either loading conditions or the mineral percentage, showing a stronger damping effect upon faster inputs compatible to the bone behavior at the macroscale. Our results offer insights into the dissipative behavior of mineralized collagen composites to design and characterize bioinspired composites for replacement devices (e.g., prostheses for sound transmission or conduction) or optimized structures able to bear transient loads, for example, impact, fatigue, in structural applications.
Collapse
Affiliation(s)
- Mario Milazzo
- Laboratory for Atomistic and Molecular Mechanics (LAMM), Massachusetts Institute of Technology, 77 Massachusetts Avenue, Cambridge, Massachusetts 02139, United States
- The BioRobotics Institute, Scuola Su periore Sant'Anna, Viale Rinaldo Piaggio 34, 56025 Pontedera, Pisa, Italy
| | - Gang Seob Jung
- Laboratory for Atomistic and Molecular Mechanics (LAMM), Massachusetts Institute of Technology, 77 Massachusetts Avenue, Cambridge, Massachusetts 02139, United States
| | - Serena Danti
- Laboratory for Atomistic and Molecular Mechanics (LAMM), Massachusetts Institute of Technology, 77 Massachusetts Avenue, Cambridge, Massachusetts 02139, United States
- The BioRobotics Institute, Scuola Su periore Sant'Anna, Viale Rinaldo Piaggio 34, 56025 Pontedera, Pisa, Italy
- Department of Civil and Industrial Engineering, University of Pisa, Largo L. Lazzarino 2, 56122 Pisa, Italy
| | - Markus J Buehler
- Laboratory for Atomistic and Molecular Mechanics (LAMM), Massachusetts Institute of Technology, 77 Massachusetts Avenue, Cambridge, Massachusetts 02139, United States
- Center for Computational Science and Engineering, Schwarzman College of Computing, Massachusetts Institute of Technology, 77 Massachusetts Avenue, Cambridge, Massachusetts 02139, United States
| |
Collapse
|
33
|
Tympanic Membrane Collagen Expression by Dynamically Cultured Human Mesenchymal Stromal Cell/Star-Branched Poly(ε-Caprolactone) Nonwoven Constructs. APPLIED SCIENCES-BASEL 2020. [DOI: 10.3390/app10093043] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Abstract
The tympanic membrane (TM) primes the sound transmission mechanism due to special fibrous layers mainly of collagens II, III, and IV as a product of TM fibroblasts, while type I is less represented. In this study, human mesenchymal stromal cells (hMSCs) were cultured on star-branched poly(ε-caprolactone) (*PCL)-based nonwovens using a TM bioreactor and proper differentiating factors to induce the expression of the TM collagen types. The cell cultures were carried out for one week under static and dynamic conditions. Reverse transcriptase-polymerase chain reaction (RT-PCR) and immunohistochemistry (IHC) were used to assess collagen expression. A Finite Element Model was applied to calculate the stress distribution on the scaffolds under dynamic culture. Nanohydroxyapatite (HA) was used as a filler to change density and tensile strength of *PCL scaffolds. In dynamically cultured *PCL constructs, fibroblast surface marker was overexpressed, and collagen type II was revealed via IHC. Collagen types I, III and IV were also detected. Von Mises stress maps showed that during the bioreactor motion, the maximum stress in *PCL was double that in HA/*PCL scaffolds. By using a *PCL nonwoven scaffold, with suitable physico-mechanical properties, an oscillatory culture, and proper differentiative factors, hMSCs were committed into fibroblast lineage-producing TM-like collagens.
Collapse
|
34
|
Polanik MD, Trakimas DR, Black NL, Cheng JT, Kozin ED, Remenschneider AK. High-Frequency Conductive Hearing following Total Drum Replacement Tympanoplasty. Otolaryngol Head Neck Surg 2020; 162:914-921. [PMID: 32097057 DOI: 10.1177/0194599820907600] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
OBJECTIVES Conventional reporting of posttympanoplasty hearing outcomes use a pure-tone averaged air-bone gap (ABG) largely representing a low-frequency sound conduction. Few studies report high-frequency conductive hearing outcomes. Herein, we evaluate high-frequency ABG in patients following temporalis fascia total drum replacement. STUDY DESIGN Case series with chart review. SETTING Tertiary care center. SUBJECTS AND METHODS All patients who underwent type 1 tympanoplasty using a lateral graft total drum replacement technique between August 2016 and February 2019 were identified. Patients with pre- and postoperative audiograms were included. Low-frequency ABG was calculated as the mean ABG at 250, 500, and 1000 Hz. High-frequency ABG was calculated at 4 KHz. Pre- and postoperative ABGs were compared. RESULTS Twenty-three patients were included, and the mean age at surgery was 44 years (range, 9-68 years). Perforation etiology was from trauma (n = 14) or chronic otitis media (n = 9). Preoperative mean low-frequency ABG was 27.8 ± 12.6 dB and mean high-frequency ABG was 21.5 ± 15.1 dB (P = .044). Postoperatively, the mean low-frequency ABG was significantly reduced by 15.5 ± 13.3 dB (P < .001) while the mean high-frequency ABG insignificantly changed (reduced by 2.6 ± 16.2 dB, P = .450). CONCLUSION In a series of patients undergoing temporalis fascia total drum replacement, low-frequency ABG improved; however, high-frequency conductive hearing loss persists. Conventional methods of reporting ABG may not identify persistent high-frequency ABG. These results merit further study across a range of tympanoplasty graft materials and surgical techniques.
Collapse
Affiliation(s)
- Marc D Polanik
- Department of Otolaryngology, Massachusetts Eye and Ear Infirmary, Boston, Massachusetts, USA.,Department of Otolaryngology, UMass Memorial Medical Center, Worcester, Massachusetts, USA.,University of Massachusetts Medical School, Worcester, Massachusetts, USA
| | - Danielle R Trakimas
- Department of Otolaryngology-Head & Neck Surgery, Johns Hopkins School of Medicine, Baltimore, Maryland, USA
| | - Nicole L Black
- Department of Otolaryngology, Massachusetts Eye and Ear Infirmary, Boston, Massachusetts, USA
| | - Jeffrey T Cheng
- Department of Otolaryngology, Massachusetts Eye and Ear Infirmary, Boston, Massachusetts, USA.,Department of Otolaryngology, Harvard Medical School, Boston, Massachusetts, USA
| | - Elliott D Kozin
- Department of Otolaryngology, Massachusetts Eye and Ear Infirmary, Boston, Massachusetts, USA.,Department of Otolaryngology, Harvard Medical School, Boston, Massachusetts, USA
| | - Aaron K Remenschneider
- Department of Otolaryngology, Massachusetts Eye and Ear Infirmary, Boston, Massachusetts, USA.,Department of Otolaryngology, UMass Memorial Medical Center, Worcester, Massachusetts, USA.,University of Massachusetts Medical School, Worcester, Massachusetts, USA.,Department of Otolaryngology, Harvard Medical School, Boston, Massachusetts, USA
| |
Collapse
|
35
|
Milazzo M, Jung GS, Danti S, Buehler MJ. Wave Propagation and Energy Dissipation in Collagen Molecules. ACS Biomater Sci Eng 2020; 6:1367-1374. [PMID: 33455394 DOI: 10.1021/acsbiomaterials.9b01742] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Collagen is the key protein of connective tissue (i.e., skin, tendons and ligaments, and cartilage, among others), accounting for 25-35% of the whole-body protein content and conferring mechanical stability. This protein is also a fundamental building block of bone because of its excellent mechanical properties together with carbonated hydroxyapatite minerals. Although the mechanical resilience and viscoelasticity have been studied both in vitro and in vivo from the molecular to tissue level, wave propagation properties and energy dissipation have not yet been deeply explored, in spite of being crucial to understanding the vibration dynamics of collagenous structures (e.g., eardrum, cochlear membranes) upon impulsive loads. By using a bottom-up atomistic modeling approach, here we study a collagen peptide under two distinct impulsive displacement loads, including longitudinal and transversal inputs. Using a one-dimensional string model as a model system, we investigate the roles of hydration and load direction on wave propagation along the collagen peptide and the related energy dissipation. We find that wave transmission and energy-dissipation strongly depend on the loading direction. Also, the hydrated collagen peptide can dissipate five times more energy than dehydrated one. Our work suggests a distinct role of collagen in term of wave transmission of different tissues such as tendon and eardrum. This study can step toward understanding the mechanical behavior of collagen upon transient loads, impact loading and fatigue, and designing biomimetic and bioinspired materials to replace specific native tissues such as the tympanic membrane.
Collapse
Affiliation(s)
- Mario Milazzo
- Laboratory for Atomistic and Molecular Mechanics (LAMM), Department of Civil and Environmental Engineering, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, United States.,The BioRobotics Institute, Scuola Superiore Sant'Anna, Pisa 56127, Italy
| | - Gang Seob Jung
- Laboratory for Atomistic and Molecular Mechanics (LAMM), Department of Civil and Environmental Engineering, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, United States
| | - Serena Danti
- Laboratory for Atomistic and Molecular Mechanics (LAMM), Department of Civil and Environmental Engineering, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, United States.,The BioRobotics Institute, Scuola Superiore Sant'Anna, Pisa 56127, Italy.,Department of Civil and Industrial Engineering, University of Pisa, Pisa 56126, Italy
| | - Markus J Buehler
- Laboratory for Atomistic and Molecular Mechanics (LAMM), Department of Civil and Environmental Engineering, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, United States
| |
Collapse
|
36
|
Jabaraj DJ. Analytical Modelling of Natural Frequency of Tympanic Membrane as the Low-Frequency Limit of Hearing. Ann Biomed Eng 2020; 48:393-402. [DOI: 10.1007/s10439-019-02356-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2019] [Accepted: 09/03/2019] [Indexed: 11/25/2022]
|
37
|
Abstract
Supplemental Digital Content is available in the text. Objectives: The objective of this study was to test the ability to achieve, maintain, and subjectively benefit from extended high-frequency amplification in a real-world use scenario, with a device that restores audibility for frequencies up to 10 kHz. Design: A total of 78 participants (149 ears) with mild to moderately-severe sensorineural hearing loss completed one of two studies conducted across eight clinical sites. Participants were fitted with a light-driven contact hearing aid (the Earlens system) that directly drives the tympanic membrane, allowing extended high-frequency output and amplification with minimal acoustic feedback. Cambridge Method for Loudness Equalization 2 - High Frequency (CAM2)-prescribed gains for experienced users were used for initial fitting, and adjustments were made when required according to participant preferences for loudness and comfort or when measures of functional gain (FG) indicated that more or less gain was needed. Participants wore the devices for an extended period. Prescribed versus adjusted output and gain, frequency-specific FG, and self-perceived benefit assessed with the Abbreviated Profile of Hearing Aid Benefit, and a custom questionnaire were documented. Self-perceived benefit results were compared with those for unaided listening and to ratings with participants’ own acoustic hearing aids. Results: The prescribed low-level insertion gain from 6 to 10 kHz averaged 53 dB across all ears, with a range from 26 to 86 dB. After adjustment, the gain from 6 to 10 kHz decreased to an average of 45 dB with a range from 16 to 86 dB. Measured FG averaged 39 dB from 6 to 10 kHz with a range from 11 to 62 dB. Abbreviated Profile of Hearing Aid Benefit results revealed a significant improvement in communication relative to unaided listening, averaging 28 to 32 percentage points for the background noise, reverberation, and ease of communication subscales. Relative to participants’ own hearing aids, the subscales ease of communication and aversiveness showed small but significant improvements for Earlens ranging from 6 to 7 percentage points. For the custom satisfaction questionnaire, most participants rated the Earlens system as better than their own hearing aids in most situations. Conclusions: Participants used and reported subjective benefit from the Earlens system. Most participants preferred slightly less gain at 6 to 10 kHz than prescribed for experienced users by CAM2, preferring similar gains to those prescribed for inexperienced users, but gains over the extended high frequencies were high relative to those that are currently available with acoustic hearing aids.
Collapse
|
38
|
Muyshondt PGG, Dirckx JJJ. How flexibility and eardrum cone shape affect sound conduction in single-ossicle ears: a dynamic model study of the chicken middle ear. Biomech Model Mechanobiol 2019; 19:233-249. [PMID: 31372910 DOI: 10.1007/s10237-019-01207-4] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2019] [Accepted: 07/24/2019] [Indexed: 12/21/2022]
Abstract
It is believed that non-mammals have poor hearing at high frequencies because the sound-conduction performance of their single-ossicle middle ears declines above a certain frequency. To better understand this behavior, a dynamic three-dimensional finite-element model of the chicken middle ear was constructed. The effect of changing the flexibility of the cartilaginous extracolumella on middle-ear sound conduction was simulated from 0.125 to 8 kHz, and the influence of the outward-bulging cone shape of the eardrum was studied by altering the depth and orientation of the eardrum cone in the model. It was found that extracolumella flexibility increases the middle-ear pressure gain at low frequencies due to an enhancement of eardrum motion, but it decreases the pressure gain at high frequencies as the bony columella becomes more resistant to extracolumella movement. Similar to the inward-pointing cone shape of the mammalian eardrum, it was shown that the outward-pointing cone shape of the chicken eardrum enhances the middle-ear pressure gain compared to a flat eardrum shape. When the outward-pointing eardrum was replaced by an inward-pointing eardrum, the pressure gain decreased slightly over the entire frequency range. This decrease was assigned to an increase in bending behavior of the extracolumella and a reduction in piston-like columella motion in the model with an inward-pointing eardrum. Possibly, the single-ossicle middle ear of birds favors an outward-pointing eardrum over an inward-pointing one as it preserves a straight angle between the columella and extrastapedius and a right angle between the columella and suprastapedius, which provides the optimal transmission.
Collapse
Affiliation(s)
- Pieter G G Muyshondt
- Biophysics and Biomedical Physics, University of Antwerp, Groenenborgerlaan 171, 2020, Antwerp, Belgium.
| | - Joris J J Dirckx
- Biophysics and Biomedical Physics, University of Antwerp, Groenenborgerlaan 171, 2020, Antwerp, Belgium
| |
Collapse
|
39
|
Tang H, Razavi P, Pooladvand K, Psota P, Maftoon N, Rosowski JJ, Furlong C, Cheng JT. High-Speed Holographic Shape and Full-Field Displacement Measurements of the Tympanic Membrane in Normal and Experimentally Simulated Pathological Ears. APPLIED SCIENCES (BASEL, SWITZERLAND) 2019; 9:2809. [PMID: 32802482 PMCID: PMC7425804 DOI: 10.3390/app9142809] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
To improve the understanding of the middle-ear hearing mechanism and assist in the diagnosis of middle-ear diseases, we are developing a high-speed digital holographic (HDH) system to measure the shape and acoustically-induced transient displacements of the tympanic membrane (TM). In this paper, we performed measurements on cadaveric human ears with simulated common middle-ear pathologies. The frequency response function (FRF) of the normalized displacement by the stimulus (sound pressure) at each measured pixel point of the entire TM surface was calculated and the complex modal indicator function (CMIF) of the middle-ear system based on FRFs of the entire TM surface motions was used to differentiate different middle-ear pathologies. We also observed changes in the TM shape and the surface motion pattern before and after various middle-ear manipulations. The observations of distinguishable TM shapes and motion patterns in both time and frequency domains between normal and experimentally simulated pathological ears support the development of a quantitative clinical holography-based apparatus for diagnosing middle-ear pathologies.
Collapse
Affiliation(s)
- Haimi Tang
- Center for Holographic Studies and Laser Micro-mechaTronics (CHSLT), Worcester, MA 01609, USA
- Mechanical Engineering Department, Worcester Polytechnic Institute, Worcester, MA 01609, USA
| | - Payam Razavi
- Center for Holographic Studies and Laser Micro-mechaTronics (CHSLT), Worcester, MA 01609, USA
- Mechanical Engineering Department, Worcester Polytechnic Institute, Worcester, MA 01609, USA
| | - Koohyar Pooladvand
- Center for Holographic Studies and Laser Micro-mechaTronics (CHSLT), Worcester, MA 01609, USA
- Mechanical Engineering Department, Worcester Polytechnic Institute, Worcester, MA 01609, USA
| | - Pavel Psota
- Center for Holographic Studies and Laser Micro-mechaTronics (CHSLT), Worcester, MA 01609, USA
- Mechanical Engineering Department, Worcester Polytechnic Institute, Worcester, MA 01609, USA
- Faculty of Mechatronics, Informatics and Interdisciplinary Studies, Technical University of Liberec, Liberec 46117, Czech Republic
| | - Nima Maftoon
- Systems Design Engineering Department, University of Waterloo, Waterloo, ON N2L 3G1, Canada
| | - John J. Rosowski
- Eaton-Peabody Laboratory, Massachusetts Eye and Ear Infirmary, Boston, MA 02114, USA
- Department of Otolaryngology-Head and Neck Surgery, Harvard Medical School, Boston, MA 02114, USA
| | - Cosme Furlong
- Center for Holographic Studies and Laser Micro-mechaTronics (CHSLT), Worcester, MA 01609, USA
- Mechanical Engineering Department, Worcester Polytechnic Institute, Worcester, MA 01609, USA
- Eaton-Peabody Laboratory, Massachusetts Eye and Ear Infirmary, Boston, MA 02114, USA
- Department of Otolaryngology-Head and Neck Surgery, Harvard Medical School, Boston, MA 02114, USA
| | - Jeffrey T. Cheng
- Eaton-Peabody Laboratory, Massachusetts Eye and Ear Infirmary, Boston, MA 02114, USA
- Department of Otolaryngology-Head and Neck Surgery, Harvard Medical School, Boston, MA 02114, USA
| |
Collapse
|
40
|
Muyshondt PG, Aerts P, Dirckx JJ. The effect of single-ossicle ear flexibility and eardrum cone orientation on quasi-static behavior of the chicken middle ear. Hear Res 2019; 378:13-22. [DOI: 10.1016/j.heares.2018.10.011] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/31/2018] [Revised: 10/11/2018] [Accepted: 10/17/2018] [Indexed: 11/16/2022]
|
41
|
Sound localization in the lizard using internally coupled ears: A finite-element approach. Hear Res 2019; 378:23-32. [DOI: 10.1016/j.heares.2019.01.016] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/31/2018] [Revised: 01/16/2019] [Accepted: 01/20/2019] [Indexed: 11/17/2022]
|
42
|
Razavi P, Tang H, Rosowski JJ, Furlong C, Cheng JT. Combined high-speed holographic shape and full-field displacement measurements of tympanic membrane. JOURNAL OF BIOMEDICAL OPTICS 2018; 24:1-12. [PMID: 30255670 PMCID: PMC6444583 DOI: 10.1117/1.jbo.24.3.031008] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/09/2018] [Accepted: 08/27/2018] [Indexed: 06/08/2023]
Abstract
The conical shape of the tympanic membrane (TM or eardrum) plays an important role in its function, such that variations in shape alter the acoustically induced motions of the TM. We present a method that precisely determines both shape and acoustically induced transient response of the entire TM using the same optics and maintaining the same coordinate system, where the TM transient displacements due to a broadband acoustic click excitation (50-μs impulse) and the shape are consecutively measured within <200 ms. Interferograms gathered with continuous high-speed (>2 kHz) optical phase sampling during a single 100-ms wavelength tuning ramp allow precise and rapid reconstructions of the TM shape at varied resolutions (50 to 200 μm). This rapid acquisition of full-field displacements and shape is immune to slow disturbances introduced by breathing or heartbeat of live subjects. Knowledge of TM shape and displacements enables the estimation of surface normal displacements regardless of the orientation of the TM within the measurement system. The proposed method helps better define TM mechanics and provides TM structure and function information useful for the diagnosis of ear disease.
Collapse
Affiliation(s)
- Payam Razavi
- Worcester Polytechnic Institute, Center for Holographic Studies and Laser micromechaTronic, Worcester, Massachusetts, United States
- Worcester Polytechnic Institute, Mechanical Engineering Department, Worcester, Massachusetts, United States
| | - Haimi Tang
- Worcester Polytechnic Institute, Center for Holographic Studies and Laser micromechaTronic, Worcester, Massachusetts, United States
- Worcester Polytechnic Institute, Mechanical Engineering Department, Worcester, Massachusetts, United States
| | - John J. Rosowski
- Massachusetts Eye and Ear Infirmary, Harvard Medical School, Eaton–Peabody Laboratory, Department of Otolaryngology, Boston, Massachusetts, United States
- Harvard Medical School, Speech and Hearing Bioscience and Technology Program, Boston, Massachusetts, United States
| | - Cosme Furlong
- Worcester Polytechnic Institute, Center for Holographic Studies and Laser micromechaTronic, Worcester, Massachusetts, United States
- Worcester Polytechnic Institute, Mechanical Engineering Department, Worcester, Massachusetts, United States
- Massachusetts Eye and Ear Infirmary, Harvard Medical School, Eaton–Peabody Laboratory, Department of Otolaryngology, Boston, Massachusetts, United States
| | - Jeffrey T. Cheng
- Massachusetts Eye and Ear Infirmary, Harvard Medical School, Eaton–Peabody Laboratory, Department of Otolaryngology, Boston, Massachusetts, United States
- Harvard Medical School, Speech and Hearing Bioscience and Technology Program, Boston, Massachusetts, United States
| |
Collapse
|
43
|
Ng C, Liang W, Gan CW, Lim HY, Tan KK. Novel Design and Validation of a Micro Instrument in an Ear Grommet Insertion Device. J Med Device 2018. [DOI: 10.1115/1.4040185] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022] Open
Abstract
An automated surgical device, the ventilator tube applicator (VTA), enables a grommet insertion surgery for patients with otitis media with effusion (OME) to be completed in a short time automatically and precisely, eliminating the use of general anesthesia (GA) typically required in such procedure. However, its current design limits the usefulness of the device as it is restricted by the properties of the tympanic membrane (TM), such as angle, thickness, and strength. Therefore, a novel design was conceptualized and the insertion control algorithm was improved to overcome the current challenges of the VTA. This innovative cover-cutter instrument design allows three-dimensional (3D) motion on an oblique surface using a single axis actuator. Experimental results on mock membranes showed great improvements in terms of robustness and success rate. The new design allowed the procedure to be performed on wider range of TM angles and hence increased the effectiveness of VTA. Grommet insertion force was reduced by an average of 66%, and the overall peak force reduced by an average of 14%. Finite element (FE) analysis on a cadaveric TM model further validated the usefulness of the cover-cutter instrument, and showed some interesting insights in the grommet insertion process.
Collapse
Affiliation(s)
- Cailin Ng
- NUS Graduate School for Integrative Sciences and Engineering, National University of Singapore, Singapore 119077 e-mail:
| | - Wenyu Liang
- Department of Electrical and Computer Engineering, National University of Singapore, Singapore 119077 e-mail:
| | - Chee Wee Gan
- Department of Otolaryngology, National University of Singapore, Singapore 119077 e-mail:
| | - Hsueh Yee Lim
- Department of Otolaryngology, National University of Singapore, Singapore 119077 e-mail:
| | - Kok Kiong Tan
- Department of Electrical and Computer Engineering, National University of Singapore, Singapore 119077 e-mail:
| |
Collapse
|
44
|
Eldaebes MMAS, Landry TG, Bance ML. Effects of Cartilage Overlay on the Tympanic Membrane: Lessons From a Temporal Bone Study for Cartilage Tympanoplasty. Otol Neurotol 2018; 39:995-1004. [PMID: 29957671 DOI: 10.1097/mao.0000000000001888] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
HYPOTHESIS Placing cartilage grafts on different tympanic membrane (TM) locations will affect sound transfer function, and the effects will differ according to the part of the TM modified. BACKGROUND Cartilage tympanoplasty is increasingly popular because of lower reperforation rates, and better long-term stability. In this temporal bone study, we investigated the effect of placing cartilage grafts over different parts of the normal TM on sound transmission. METHODS In 10 human fresh frozen temporal bones, umbo and stapes vibrations to acoustic stimuli from 250 to 8000 Hz were measured at multiple points using a scanning laser vibrometer. Four different cartilage arrangements were measured in each temporal bone. 1) Overlay condition leaving an umbo rim of normal TM (Umbo Rim). 2) Overlay condition leaving annular rim of normal TM (Annular Rim). 3) Overlay condition leaving both rims of normal TM (Two Rims). 4) Overlay condition leaving no normal TM exposed (No Rims). RESULTS At low frequencies, there was a statistically significant decrease in velocity from baseline for the No Rims (umbo mean -4 dB; stapes -6 dB) and Umbo Rim (umbo -4 dB; stapes -3.7 dB) conditions. All conditions showed significant decreases for middle frequencies (umbo -4.0, -5.9, -7.4 and -6.3 dB; stapes -10.8, -6.6, -6.3 and -7.7 dB) and high frequencies (umbo -13.2, -3.0, -3.1 and -5.5 dB; stapes -4.6, -2.4, -2.6 and -3.5 dB). Results are in order for No Rims, Umbo Rim, Two Rims, and Annular Rim conditions. CONCLUSION In the low frequencies, it seems to matter where the cartilage is placed, and in particular the annular rim of the TM seems to be important for the low-frequency acoustic transfer function. In the higher frequencies, all graft placements caused some drop at all frequencies. In all frequencies, effects were modest by clinical standards.
Collapse
Affiliation(s)
| | - Thomas G Landry
- Division of Otolaryngology, Nova Scotia Health Authority, Halifax, Nova Scotia, Canada
| | - Manohar L Bance
- Division of Otolaryngology, Department of Surgery, Dalhousie University.,Department of Clinical Neuroscience, University of Cambridge, Cambridge, UK
| |
Collapse
|
45
|
Iversen MM, Rabbitt RD. Wave Mechanics of the Vestibular Semicircular Canals. Biophys J 2017; 113:1133-1149. [PMID: 28877495 DOI: 10.1016/j.bpj.2017.08.001] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2017] [Revised: 07/14/2017] [Accepted: 08/02/2017] [Indexed: 01/08/2023] Open
Abstract
The semicircular canals are biomechanical sensors responsible for detecting and encoding angular motion of the head in 3D space. Canal afferent neurons provide essential inputs to neural circuits responsible for representation of self-position/orientation in space, and to compensatory circuits including the vestibulo-ocular and vestibulo-collic reflex arcs. In this work we derive, to our knowledge, a new 1D mathematical model quantifying canal biomechanics based on the morphology, dynamics of the inner ear fluids, and membranous labyrinth deformability. The model takes the form of a dispersive wave equation and predicts canal responses to angular motion, sound, and mechanical stimulation. Numerical simulations were carried out for the morphology of the human lateral canal using known physical properties of the endolymph and perilymph in three diverse conditions: surgical plugging, rotation, and mechanical indentation. The model reproduces frequency-dependent attenuation and phase shift in cases of canal plugging. During rotation, duct deformability extends the frequency bandwidth and enhances the high frequency gain. Mechanical indentation of the membranous duct at high frequencies evokes traveling waves that move away from the location of indentation and at low frequencies compels endolymph displacement along the canal. These results demonstrate the importance of the conformal perilymph-filled bony labyrinth to pressure changes and to high frequency sound and vibration.
Collapse
Affiliation(s)
- Marta M Iversen
- Department of Bioengineering, University of Utah, Salt Lake City, Utah.
| | - Richard D Rabbitt
- Department of Bioengineering, University of Utah, Salt Lake City, Utah; Department of Otolaryngology, University of Utah, Salt Lake City, Utah; Marine Biological Laboratory, Woods Hole, Massachusetts
| |
Collapse
|
46
|
O'Connor KN, Cai H, Puria S. The effects of varying tympanic-membrane material properties on human middle-ear sound transmission in a three-dimensional finite-element model. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2017; 142:2836. [PMID: 29195482 PMCID: PMC5681352 DOI: 10.1121/1.5008741] [Citation(s) in RCA: 31] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/02/2023]
Abstract
An anatomically based three-dimensional finite-element human middle-ear (ME) model is used to test the sensitivity of ME sound transmission to tympanic-membrane (TM) material properties. The baseline properties produce responses comparable to published measurements of ear-canal input impedance and power reflectance, stapes velocity normalized by ear-canal pressure (PEC), and middle-ear pressure gain (MEG), i.e., cochlear-vestibule pressure (PV) normalized by PEC. The mass, Young's modulus (ETM), and shear modulus (GTM) of the TM are varied, independently and in combination, over a wide range of values, with soft and bony TM-annulus boundary conditions. MEG is recomputed and plotted for each case, along with summaries of the magnitude and group-delay deviations from the baseline over low (below 0.75 kHz), mid (0.75-5 kHz), and high (above 5 kHz) frequencies. The MEG magnitude varies inversely with increasing TM mass at high frequencies. Increasing ETM boosts high frequencies and attenuates low and mid frequencies, especially with a bony TM annulus and when GTM varies in proportion to ETM, as for an isotropic material. Increasing GTM on its own attenuates low and mid frequencies and boosts high frequencies. The sensitivity of MEG to TM material properties has implications for model development and the interpretation of experimental observations.
Collapse
Affiliation(s)
- Kevin N O'Connor
- Department of Mechanical Engineering, Stanford University, Stanford, California 94305, USA
| | - Hongxue Cai
- Department of Mechanical Engineering, Stanford University, Stanford, California 94305, USA
| | - Sunil Puria
- Department of Otology and Laryngology, Harvard Medical School, Eaton-Peabody Laboratories, Massachusetts Eye and Ear Infirmary, 243 Charles Street, Boston, Massachusetts 02114, USA
| |
Collapse
|
47
|
Santa Maria PL, Gottlieb P, Santa Maria C, Kim S, Puria S, Yang YP. Functional Outcomes of Heparin-Binding Epidermal Growth Factor-Like Growth Factor for Regeneration of Chronic Tympanic Membrane Perforations in Mice. Tissue Eng Part A 2017; 23:436-444. [PMID: 28142401 PMCID: PMC5444491 DOI: 10.1089/ten.tea.2016.0395] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2016] [Accepted: 01/27/2017] [Indexed: 02/02/2023] Open
Abstract
We aim to demonstrate that regeneration of chronic tympanic perforations with heparin-binding epidermal growth factor-like growth factor (HB-EGF) delivered by an injectable hydrogel restored hearing to levels similar to that of nonperforated tympanic membranes. Chronic tympanic membrane perforation is currently managed as an outpatient surgery with tympanoplasty. Due to the costs of this procedure in the developed world and a lack of accessibility and resources in developing countries, there is a great need for a new treatment that does not require surgery. In this study, we show in a mouse model through measurement of auditory brainstem response and distortion product otoacoustic emissions that tympanic perforations lead to hearing loss and this can be predominantly recovered with HB-EGF treatment (5 μg/mL). Our animal model suggests a return to function between 2 and 6 months after treatment. Auditory brainstem response thresholds had returned to the control levels at 2 months, but the distortion product otoacoustic emissions returned between 2 and 6 months. We also show how the vibration characteristics of the regenerated tympanic membrane, as measured by laser Doppler vibrometry, can be similar to that of an unperforated tympanic membrane. Using the best available methods for preclinical evaluation in animal models, it is likely that HB-EGF-like growth factor treatment leads to regeneration of chronic tympanic membrane perforations and restoration of the tympanic membrane to normal function, suggesting a potential route for nonsurgical treatment.
Collapse
Affiliation(s)
- Peter Luke Santa Maria
- Department of Otolaryngology, Head and Neck Surgery, Stanford University, Stanford, California
- Ear Sciences Centre, The University of Western Australia, Nedlands, Australia
- Ear Science Institute Australia, Subiaco, Australia
| | - Peter Gottlieb
- Department of Mechanical Engineering, Stanford University, Stanford, California
| | - Chloe Santa Maria
- Department of Otolaryngology, Head and Neck Surgery, Stanford University, Stanford, California
- Ear Sciences Centre, The University of Western Australia, Nedlands, Australia
- Ear Science Institute Australia, Subiaco, Australia
| | - Sungwoo Kim
- Department of Orthopedic Surgery, Stanford University, Stanford, California
| | - Sunil Puria
- Department of Otolaryngology, Head and Neck Surgery, Stanford University, Stanford, California
- Department of Mechanical Engineering, Stanford University, Stanford, California
| | - Yunzhi Peter Yang
- Department of Orthopedic Surgery, Stanford University, Stanford, California
- Department of Materials Science and Engineering, Stanford University, Stanford, California
- Department of Bioengineering, Stanford University, Stanford, California
| |
Collapse
|
48
|
Milazzo M, Fallah E, Carapezza M, Kumar NS, Lei JH, Olson ES. The path of a click stimulus from ear canal to umbo. Hear Res 2017; 346:1-13. [PMID: 28087416 PMCID: PMC5348280 DOI: 10.1016/j.heares.2017.01.007] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/15/2016] [Revised: 12/22/2016] [Accepted: 01/02/2017] [Indexed: 11/29/2022]
Abstract
The tympanic membrane (TM) has a key role in transmitting sounds to the inner ear, but a concise description of how the TM performs this function remains elusive. This paper probes TM operation by applying a free field click stimulus to the gerbil ear and exploring the consequent motions of the TM and umbo. Motions of the TM were measured both on radial tracks starting close to the umbo and on a grid distal and adjacent to the umbo. The experimental results confirmed the high fidelity of sound transmission from the ear canal to the umbo. A delay of 5-15 μs was seen in the onset of TM motion between points just adjacent to the umbo and mid-radial points. The TM responded with a ringing motion, with different locations possessing different primary ringing frequencies. A simple analytic model from the literature, treating the TM as a string, was used to explore the experimental results. The click-based experiments and analysis led to the following description of TM operation: A transient sound pressure on the TM causes a transient initial TM motion that is maximal ∼ at the TM's radial midpoints. Mechanical forces generated by this initial prominent TM distortion then pull the umbo inward, leading to a delayed umbo response. The initial TM deformation also gives rise to prolonged mechanical ringing on the TM that does not result in significant umbo motion, likely due to destructive interference from the range of ringing frequencies. Thus, the umbo's response is a high-fidelity representation of the transient stimulus. Because any sound can be considered as a consecutive series of clicks, this description is applicable to any sound stimulus.
Collapse
Affiliation(s)
- Mario Milazzo
- The BioRobotics Institute, Scuola Superiore Sant' Anna, Viale R. Piaggio 34, 56025 Pontedera, Italy
| | - Elika Fallah
- Department of Otolaryngology & Head and Neck Surgery, Department of Biomedical Engineering, Columbia University, 630 West 168th Street, P&S 11-452, New York, NY 10032, USA
| | - Michael Carapezza
- Department of Otolaryngology & Head and Neck Surgery, Department of Biomedical Engineering, Columbia University, 630 West 168th Street, P&S 11-452, New York, NY 10032, USA
| | - Nina S Kumar
- Department of Otolaryngology & Head and Neck Surgery, Department of Biomedical Engineering, Columbia University, 630 West 168th Street, P&S 11-452, New York, NY 10032, USA
| | - Jason H Lei
- Department of Otolaryngology & Head and Neck Surgery, Department of Biomedical Engineering, Columbia University, 630 West 168th Street, P&S 11-452, New York, NY 10032, USA
| | - Elizabeth S Olson
- Department of Otolaryngology & Head and Neck Surgery, Department of Biomedical Engineering, Columbia University, 630 West 168th Street, P&S 11-452, New York, NY 10032, USA.
| |
Collapse
|
49
|
Estimation of the Young's modulus of the human pars tensa using in-situ pressurization and inverse finite-element analysis. Hear Res 2017; 345:69-78. [DOI: 10.1016/j.heares.2017.01.002] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/15/2016] [Revised: 01/03/2017] [Accepted: 01/05/2017] [Indexed: 11/19/2022]
|
50
|
De Greef D, Pires F, Dirckx JJ. Effects of model definitions and parameter values in finite element modeling of human middle ear mechanics. Hear Res 2017; 344:195-206. [DOI: 10.1016/j.heares.2016.11.011] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/21/2016] [Revised: 11/03/2016] [Accepted: 11/22/2016] [Indexed: 11/26/2022]
|