1
|
January JL, Tshobeni ZZ, Ngema NPP, Jijana AN, Iwuoha EI, Mulaudzi T, Douman SF, Ajayi RF. Novel Cytochrome P450-3A4 Enzymatic Nanobiosensor for Lapatinib (a Breast Cancer Drug) Developed on a Poly(anilino-co-4-aminobenzoic Acid-Green-Synthesised Indium Nanoparticle) Platform. BIOSENSORS 2023; 13:897. [PMID: 37754131 PMCID: PMC10527071 DOI: 10.3390/bios13090897] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/27/2023] [Revised: 09/15/2023] [Accepted: 09/18/2023] [Indexed: 09/28/2023]
Abstract
Breast cancer (BC) is one of the most common types of cancer disease worldwide and it accounts for thousands of deaths annually. Lapatinib is among the preferred drugs for the treatment of breast cancer. Possible drug toxicity effects of lapatinib can be controlled by real-time determination of the appropriate dose for a patient at the point of care. In this study, a novel highly sensitive polymeric nanobiosensor for lapatinib is presented. A composite of poly(anilino-co-4-aminobenzoic acid) co-polymer {poly(ANI-co-4-ABA)} and coffee extract-based green-synthesized indium nanoparticles (InNPs) was used to develop the sensor platform on a screen-printed carbon electrode (SPCE), i.e., SPCE||poly(ANI-co-4-ABA-InNPs). Cytochrome P450-3A4 (CYP3A4) enzyme and polyethylene glycol (PEG) were incorporated on the modified platform to produce the SPCE||poly(ANI-co-4-ABA-InNPs)|CYP3A4|PEG lapatinib nanobiosensor. Experiments for the determination of the electrochemical response characteristics of the nanobiosensor were performed with cyclic voltammetry (CV) and differential pulse voltammetry (DPV). The nanobiosensor calibration for 0-100 ng/mL lapatinib was linear and gave limit of detection (LOD) values of 13.21 ng/mL lapatinib and 18.6 ng/mL lapatinib in physiological buffer and human serum, respectively. The LOD values are much lower than the peak plasma concentration (Cmax) of lapatinib (2.43 µg/mL), which is attained 4 h after the administration of a daily dose of 1250 mg lapatinib. The electrochemical nanobiosensor also exhibited excellent anti-interference performance and stability.
Collapse
Affiliation(s)
- Jaymi Leigh January
- SensorLab (UWC Sensor Laboratories), University of the Western Cape, Private Bag X17, Bellville, Cape Town 7535, South Africa
| | - Ziyanda Zamaswazi Tshobeni
- SensorLab (UWC Sensor Laboratories), University of the Western Cape, Private Bag X17, Bellville, Cape Town 7535, South Africa
| | - Nokwanda Precious Pearl Ngema
- SensorLab (UWC Sensor Laboratories), University of the Western Cape, Private Bag X17, Bellville, Cape Town 7535, South Africa
| | - Abongile Nwabisa Jijana
- Nanotechnology Innovation Centre, Advanced Materials Division, Mintek, Private Bag X3015, Randburg, Johannesburg 2125, South Africa
| | - Emmanuel Iheanyichukwu Iwuoha
- SensorLab (UWC Sensor Laboratories), University of the Western Cape, Private Bag X17, Bellville, Cape Town 7535, South Africa
| | - Takalani Mulaudzi
- Department of Biotechnology, University of the Western Cape, Private Bag X17, Bellville, Cape Town 7535, South Africa
| | - Samantha Fiona Douman
- Department of Chemistry, University of Cape Town, Private Bag X3, Rondebosch, Cape Town 7701, South Africa
| | - Rachel Fanelwa Ajayi
- SensorLab (UWC Sensor Laboratories), University of the Western Cape, Private Bag X17, Bellville, Cape Town 7535, South Africa
| |
Collapse
|
2
|
Imanzadeh H, Sefid-Sefidehkhan Y, Afshary H, Afruz A, Amiri M. Nanomaterial-based electrochemical sensors for detection of amino acids. J Pharm Biomed Anal 2023; 230:115390. [PMID: 37079932 DOI: 10.1016/j.jpba.2023.115390] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2022] [Revised: 03/24/2023] [Accepted: 04/08/2023] [Indexed: 04/22/2023]
Abstract
Amino acids are the building blocks of proteins and muscle tissue. They also play a significant role in physiological processes related to energy, recovery, mood, muscle and brain function, fat burning and stimulating growth hormone or insulin secretion. Accurate determination of amino acids in biological fluids is necessary because any changes in their normal ranges in the body warn diseases like kidney disease, liver disease, type 2 diabetes and cancer. To date, many methods such as liquid chromatography, fluorescence mass spectrometry, etc. have been used for the determination of amino acids. Compared with the above techniques, electrochemical systems using modified electrodes offer a rapid, accurate, cheap, real-time analytical path through simple operations with high selectivity and sensitivity. Nanomaterials have found many interests to create smart electrochemical sensors in different application fields e.g. biomedical, environmental, and food analysis because of their exceptional properties. This review summarizes recent advances in the development of nanomaterial-based electrochemical sensors in 2017-2022 for the detection of amino acids in various matrices such as serum, urine, blood and pharmaceuticals.
Collapse
Affiliation(s)
- Hamideh Imanzadeh
- Department of Chemistry, University of Mohaghegh Ardabili, Ardabil, Iran
| | | | - Hosein Afshary
- Department of Chemistry, University of Mohaghegh Ardabili, Ardabil, Iran
| | - Ali Afruz
- Department of Chemistry, University of Mohaghegh Ardabili, Ardabil, Iran
| | - Mandana Amiri
- Department of Chemistry, University of Mohaghegh Ardabili, Ardabil, Iran.
| |
Collapse
|
3
|
Zambrano-Intriago LA, Amorim CG, Araújo AN, Gritsok D, Rodríguez-Díaz JM, Montenegro MCBSM. Development of an inexpensive and rapidly preparable enzymatic pencil graphite biosensor for monitoring of glyphosate in waters. THE SCIENCE OF THE TOTAL ENVIRONMENT 2023; 855:158865. [PMID: 36165910 DOI: 10.1016/j.scitotenv.2022.158865] [Citation(s) in RCA: 13] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/06/2022] [Revised: 09/11/2022] [Accepted: 09/15/2022] [Indexed: 06/16/2023]
Abstract
Glyphosate (GLY) is the most widely used non-selective broad-spectrum herbicide worldwide under well-reported side effects on the environment and human health. That's why it's necessary to control its presence in the environment. This work describes the development of an affordable, simple, and accurate electrochemical biosensor using a pencil graphite electrode as support, a horseradish peroxidase enzyme immobilized on a polysulfone membrane doped with multi-walled carbon nanotubes. The developed electrochemical sensor was used in the determination of GLY in river and drinking water samples. Cyclic voltammetry and amperometry were used as electrochemical detection techniques for the characterization and analytical application of the developed biosensor. The working mechanism of the biosensor is based on the inhibition of the peroxidase enzyme by GLY. Under optimal experimental conditions, the biosensor showed a linear response in the concentration range of 0.1 to 10 mg L-1. The limits of detection and quantification are 0.025 ± 0.002 and 0.084 ± 0.007 mg L-1, respectively, which covers the maximum residual limit established by the EPA for drinking water (0.7 mg L-1). The proposed biosensor demonstrated high reproducibility, excellent analytical performance, repeatability, and accuracy. The sensor proved to be selective against other pesticides, organic acids, and inorganic salts. Application on real samples showed recovery rates ranging between 98.18 ± 0.11 % and 97.32 ± 0.23 %. The analytical features of the proposed biosensor make it an effective and useful tool for the detection of GLY for environmental analysis.
Collapse
Affiliation(s)
- Luis Angel Zambrano-Intriago
- LAQV-REQUIMTE/Departamento de Ciências Químicas, Faculdade de Farmácia, Universidade do Porto, R. Jorge Viterbo Ferreira, 228, 4050-313 Porto, Portugal; Laboratorio de Análisis Químicos y Biotecnológicos, Instituto de Investigación, Universidad Técnica de Manabí, Portoviejo 130105, Ecuador
| | - Célia G Amorim
- LAQV-REQUIMTE/Departamento de Ciências Químicas, Faculdade de Farmácia, Universidade do Porto, R. Jorge Viterbo Ferreira, 228, 4050-313 Porto, Portugal.
| | - Alberto N Araújo
- LAQV-REQUIMTE/Departamento de Ciências Químicas, Faculdade de Farmácia, Universidade do Porto, R. Jorge Viterbo Ferreira, 228, 4050-313 Porto, Portugal
| | - Dmitrij Gritsok
- LAQV-REQUIMTE/Departamento de Ciências Químicas, Faculdade de Farmácia, Universidade do Porto, R. Jorge Viterbo Ferreira, 228, 4050-313 Porto, Portugal
| | - Joan Manuel Rodríguez-Díaz
- Laboratorio de Análisis Químicos y Biotecnológicos, Instituto de Investigación, Universidad Técnica de Manabí, Portoviejo 130105, Ecuador; Departamento de Procesos Químicos, Facultad de Ciencias Matemáticas, Físicas y Químicas, Universidad Técnica de Manabí, Portoviejo 130105, Ecuador.
| | - Maria C B S M Montenegro
- LAQV-REQUIMTE/Departamento de Ciências Químicas, Faculdade de Farmácia, Universidade do Porto, R. Jorge Viterbo Ferreira, 228, 4050-313 Porto, Portugal.
| |
Collapse
|
4
|
Varodi C, Pogăcean F, Coroş M, Ciorîță A, Pruneanu S. Electrochemical L-Tyrosine Sensor Based on a Glassy Carbon Electrode Modified with Exfoliated Graphene. SENSORS 2022; 22:s22103606. [PMID: 35632015 PMCID: PMC9143931 DOI: 10.3390/s22103606] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/18/2022] [Revised: 05/04/2022] [Accepted: 05/06/2022] [Indexed: 01/23/2023]
Abstract
In this study, a graphene sample (EGr) was synthesized by electrochemical exfoliation of graphite rods in electrolyte solution containing 0.1 M ammonia and 0.1 M ammonium thiocyanate. The morphology of the powder deposited onto a solid substrate was investigated by the scanning electron microscopy (SEM) technique. The SEM micrographs evidenced large and smooth areas corresponding to the basal plane of graphene as well as white lines (edges) where graphene layers fold-up. The high porosity of the material brings a major advantage, such as the increase of the active area of the modified electrode (EGr/GC) in comparison with that of bare glassy carbon (GC). The graphene modified electrode was successfully tested for L-tyrosine detection and the results were compared with those of bare GC. For EGr/GC, the oxidation peak of L-tyrosine had high intensity (1.69 × 10-5 A) and appeared at lower potential (+0.64 V) comparing with that of bare GC (+0.84 V). In addition, the graphene-modified electrode had a considerably larger sensitivity (0.0124 A/M) and lower detection limit (1.81 × 10-6 M), proving the advantages of employing graphene in electrochemical sensing.
Collapse
|
5
|
Dinu A, Apetrei C. Quantification of Tyrosine in Pharmaceuticals with the New Biosensor Based on Laccase-Modified Polypyrrole Polymeric Thin Film. Polymers (Basel) 2022; 14:441. [PMID: 35160431 PMCID: PMC8839761 DOI: 10.3390/polym14030441] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2021] [Revised: 01/15/2022] [Accepted: 01/21/2022] [Indexed: 12/17/2022] Open
Abstract
Stress, a state of body tension, sometimes caused by increased levels of tyrosine (Tyr) in the body, can lead to serious illnesses such as depression, irritability, anxiety, damage to the thyroid gland, and insomnia. The body can be provided with an adequate concentration of tyrosine by taking pharmaceutical products or by dietary intake. Therefore, this study presents the development of a new enzyme sensor for the quantification of Tyr in pharmaceuticals. A screen-printed carbon electrode (SPCE) was modified with the conductive polymer (CP) polypyrrole (PPy) doped with hexacyanoferrate (II) anion (FeCN), the polymer having been selected for its excellent properties, namely, permeability, conductivity, and stability. The enzyme laccase (Lacc) was subsequently immobilized in the polymer matrix and cross-linked with glutaraldehyde, as this enzyme is a thermostable catalyst, greatly improving the performance of the biosensor. The electrochemical method of analysis of the new device, Lacc/PPy/FeCN/SPCE, was cyclic voltammetry (CV), and chronoamperometry (CA) contributed to the study of changes in the biosensor with doped PPy. CV measurements confirmed that the Lacc/PPy/FeCN/SPCE biosensor is a sensitive and efficient platform for Tyr detection. Thus, this enzyme sensor showed a very low limit of detection (LOD) of 2.29 × 10-8 M, a limit of quantification (LOQ) of 7.63 × 10-8 M, and a very high sensitivity compared to both devices reported in the literature and the PPy/FeCN/SPCE sensor. Quantitative determination in pharmaceuticals was performed in L-Tyr solution of different concentrations ranging from 0.09 to 7 × 10-6 M. Validation of the device was performed by infrared spectrometry (FT-IR) on three pharmaceuticals from different manufacturers and with different Tyr concentrations.
Collapse
Affiliation(s)
| | - Constantin Apetrei
- Department of Chemistry, Physics and Environment, Faculty of Sciences and Environment, “Dunărea de Jos” University of Galati, 47 Domnească Street, RO-800008 Galati, Romania;
| |
Collapse
|
6
|
Stoikov D, Ivanov A, Shurpik D, Stoikov I, Evtugyn G. Flow-Through Electrochemical Biosensor with a Replaceable Enzyme Reactor and Screen-Printed Electrode for the Determination of Uric Acid and Tyrosine. ANAL LETT 2021. [DOI: 10.1080/00032719.2021.2000621] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
Affiliation(s)
- Dmitrii Stoikov
- A.M. Butlerov Chemistry Institute, Kazan Federal University, Kazan, Russia
| | - Alexey Ivanov
- A.M. Butlerov Chemistry Institute, Kazan Federal University, Kazan, Russia
| | - Dmitriy Shurpik
- A.M. Butlerov Chemistry Institute, Kazan Federal University, Kazan, Russia
| | - Ivan Stoikov
- A.M. Butlerov Chemistry Institute, Kazan Federal University, Kazan, Russia
| | - Gennady Evtugyn
- A.M. Butlerov Chemistry Institute, Kazan Federal University, Kazan, Russia
- Analytical Chemistry Department, Chemical Technology Institute of Ural Federal University, Ekaterinburg, Russia
| |
Collapse
|
7
|
Dinu A, Apetrei C. Development of Polypyrrole Modified Screen-Printed Carbon Electrode Based Sensors for Determination of L-Tyrosine in Pharmaceutical Products. Int J Mol Sci 2021; 22:7528. [PMID: 34299146 PMCID: PMC8307433 DOI: 10.3390/ijms22147528] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2021] [Revised: 07/07/2021] [Accepted: 07/13/2021] [Indexed: 12/21/2022] Open
Abstract
Good health, of vital importance in order to carry out our daily routine, consists of both physical and mental health. Tyrosine (Tyr) deficiency as well as its excess are issues that can affect mental health and can generate disorders such as depression, anxiety, or stress. Tyr is the amino acid (AA) responsible for maintaining good mental health, and for this reason, the present research presents the development of new electrochemical sensors modified with polypyrrole (PPy) doped with different doping agents such as potassium hexacyanoferrate (II) (FeCN), sodium nitroprusside (NP), and sodium dodecyl sulfate (SDS) for a selective and sensitive detection of Tyr. The development of the sensors was carried out by chronoamperometry (CA) and the electrochemical characterization was carried out by cyclic voltammetry (CV). The detection limits (LOD) obtained with each modified sensor were 8.2 × 10-8 M in the case of PPy /FeCN-SPCE, 4.3 × 10-7 M in the case of PPy/NP-SPCE, and of 3.51 × 10-7 M in the case of PPy/SDS-SPCE, thus demonstrating a good sensitivity of these sensors detecting L-Tyr. The validation of sensors was carried out through quantification of L-Tyr from three pharmaceutical products by the standard addition method with recoveries in the range 99.92-103.97%. Thus, the sensors present adequate selectivity and can be used in the pharmaceutical and medical fields.
Collapse
Affiliation(s)
| | - Constantin Apetrei
- Faculty of Science and Environment, “Dunărea de Jos” University of Galati, 800008 Galati, Romania;
| |
Collapse
|
8
|
Tajik S, Garkani-Nejad Z, Mahmoudi-Moghaddam H, Beitollahi H, Khabazzadeh H. Electrochemical Determination of Levodopa and Cabergoline by a Magnetic Core-Shell Iron (II,III) Oxide@Silica/Multiwalled Carbon Nanotube/Ionic Liquid/2-(4-Oxo-3-Phenyl-3,4-Dihydroquinazolinyl)- N′-Phenyl-Hydrazine Carbothioamide (FSCNT/IL/2PHC) Modified Carbon Paste Electrode. ANAL LETT 2021. [DOI: 10.1080/00032719.2021.1880425] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
Affiliation(s)
- Somayeh Tajik
- Research Center of Tropical and Infectious Diseases, Kerman University of Medical Sciences, Kerman, Iran
| | - Zahra Garkani-Nejad
- Chemistry Department, Faculty of Science, Shahid Bahonar University of Kerman, Kerman, Iran
| | - Hadi Mahmoudi-Moghaddam
- Pharmaceutics Research Center, Institute of Neuropharmacology, Kerman University of Medical Sciences, Kerman, Iran
| | - Hadi Beitollahi
- Environment Department, Institute of Science and High Technology and Environmental, Sciences, Graduate University of Advanced Technology, Kerman, Iran
| | - Hojatollah Khabazzadeh
- Chemistry Department, Faculty of Science, Shahid Bahonar University of Kerman, Kerman, Iran
| |
Collapse
|
9
|
Wu XQ, Feng PQ, Guo Z, Wei X. Water-Stable 1D Double-Chain Cu Metal-Organic Framework-based Electrochemical Biosensor for Detecting l-Tyrosine. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2020; 36:14123-14129. [PMID: 33180511 DOI: 10.1021/acs.langmuir.0c02799] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
An electrochemical biosensor based on a water-stable one-dimensional double-chain Cu(II) metal-organic framework (Cu-MOF) directly was constructed for efficiently recognizing l-tyrosine (l-Tyr) in biomimic environments. Cu-MOF: {[Cu(bpe)(fdc) (H2O)(DMF)]·0.5H2O}n (bpe = 1,2-di(4-pyridyl)ethylene, H2fdc = 2,5-furandicarboxylic acid, namely, Cu-1) was synthesized by a hydrothermal method. It was characterized by IR, scanning electron microscopy, atomic force microscopy, and PXRD techniques. Cu-1 exhibited extreme solvent and thermal stability as well as excellent electroconductive character. It was coated on a glassy carbon electrode (GCE) surface to prepare an electrochemical biosensor (Cu-1/GCE) which showed preferable biosensing ability toward l-Tyr. This Cu-MOF electrochemical biosensor showed simple operation and high sensitivity toward l-Tyr in the concentration range from 0.01 to 0.09 mM. The detection limit is 5.822 μM. Furthermore, Cu-1/GCE showed extremely excellent selectivity to l-Tyr in a biomimic environment with several amino acid interferents. This new strategy exhibits great potential applications for designing MOFs with excellent electrochemical activity.
Collapse
Affiliation(s)
- Xiao-Qin Wu
- Scientific Instrument Center, Shanxi University, Taiyuan 030006, China
- Key Laboratory of Advanced Energy Materials Chemistry (Ministry of Education), Nankai University, Tianjin 300071, China
| | - Pei-Qi Feng
- Scientific Instrument Center, Shanxi University, Taiyuan 030006, China
| | - Zhiqiang Guo
- Scientific Instrument Center, Shanxi University, Taiyuan 030006, China
| | - Xuehong Wei
- Scientific Instrument Center, Shanxi University, Taiyuan 030006, China
| |
Collapse
|