Esteban-Ibañez E, Montagud-Martínez D, Sawides L, Zaytouny A, de Castro A, Sisó-Fuertes I, Barcala X, Piñero DP, Furlan WD, Dorronsoro C, Gambra E. Simulation of daily soft multifocal contact lenses using SimVis Gekko: from in-vitro and computational characterization to clinical validation. Sci Rep 2024; 14:8592. [PMID: 38615153 PMCID: PMC11016090 DOI: 10.1038/s41598-024-59178-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2023] [Accepted: 04/08/2024] [Indexed: 04/15/2024] Open
Abstract
Multifocal contact lenses (MCLs) are one of the solutions to correct presbyopia, but their adoption is not widespread. To address this situation, visual simulators can be used to refine the adaptation process. This study aims to obtain accurate simulations for a visual simulator (SimVis Gekko; 2EyesVision) of daily soft MCL designs from four manufacturers. In-vitro characterization of these MCLs-several powers and additions- was obtained using NIMO TR-1504. From the averaged relative power profiles across powers, phase maps were reconstructed and the Through-Focus Visual Strehl metric was calculated for each MCL design. The SimVis Gekko simulation corresponding to each MCL design was obtained computationally and bench-validated. Finally, the MCL simulations were clinically validated involving presbyopic patients. The clinical validation results show a good agreement between the SimVis Gekko simulations and the real MCLs for through-focus visual acuity (TF-VA) curves and VA at three real distances. All MCL designs showed a partial correlation higher than 0.90 and a Root Mean Square Error below 0.07 logMAR between the TF-VA of simulations and Real MCLs across subjects. The validity of the simulation approach using SimVis Gekko and in-vitro measurements was confirmed in this study, opening the possibility to accelerate the adaptation of MCLs.
Collapse
Affiliation(s)
- Eduardo Esteban-Ibañez
- 2EyesVision SL, Plaza de la Encina, 10, Nucleo 3, Planta 4ª, 28760, Tres Cantos, Madrid, Spain.
- Institute of Optics 'Daza de Valdés', Spanish National Research Council, IO-CSIC, Madrid, Spain.
| | - Diego Montagud-Martínez
- Centro de Tecnologías Físicas, Universitat Politècnica de València, Valencia, Spain
- Departamento de Óptica y Optometría y Ciencias de la Visión, Universitat de València, Valencia, Spain
| | - Lucie Sawides
- 2EyesVision SL, Plaza de la Encina, 10, Nucleo 3, Planta 4ª, 28760, Tres Cantos, Madrid, Spain
- Institute of Optics 'Daza de Valdés', Spanish National Research Council, IO-CSIC, Madrid, Spain
| | - Amal Zaytouny
- Institute of Optics 'Daza de Valdés', Spanish National Research Council, IO-CSIC, Madrid, Spain
| | - Alberto de Castro
- Institute of Optics 'Daza de Valdés', Spanish National Research Council, IO-CSIC, Madrid, Spain
| | - Irene Sisó-Fuertes
- 2EyesVision SL, Plaza de la Encina, 10, Nucleo 3, Planta 4ª, 28760, Tres Cantos, Madrid, Spain
| | - Xoana Barcala
- 2EyesVision SL, Plaza de la Encina, 10, Nucleo 3, Planta 4ª, 28760, Tres Cantos, Madrid, Spain
| | - David P Piñero
- Departamento de Óptica, Farmacología y Anatomía, Universidad de Alicante, Alicante, Spain
| | - Walter D Furlan
- Departamento de Óptica y Optometría y Ciencias de la Visión, Universitat de València, Valencia, Spain
| | - Carlos Dorronsoro
- 2EyesVision SL, Plaza de la Encina, 10, Nucleo 3, Planta 4ª, 28760, Tres Cantos, Madrid, Spain
- Institute of Optics 'Daza de Valdés', Spanish National Research Council, IO-CSIC, Madrid, Spain
| | - Enrique Gambra
- 2EyesVision SL, Plaza de la Encina, 10, Nucleo 3, Planta 4ª, 28760, Tres Cantos, Madrid, Spain
| |
Collapse
|
2
|
Ritchey ER, Gregory HR, Nti AN, Berntsen DA. Intraocular Straylight and Multifocal Soft Contact Lens Fit With a Myopia Control Approach. Eye Contact Lens 2024; 50:171-176. [PMID: 38345090 PMCID: PMC10963149 DOI: 10.1097/icl.0000000000001069] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 12/07/2023] [Indexed: 03/26/2024]
Abstract
OBJECTIVES Center-distance multifocal contact lenses (MFCLs) are used to slow myopia progression. We examined the effect of two MFCLs on intraocular straylight values in myopic individuals. METHODS Twenty-five young myopic adults were enrolled and were fit with three contact lenses (Biofinity sphere, Biofinity Multifocal, and NaturalVue Multifocal) in a random order over two study visits. Pupil size (NeurOptics VIP-300, Laguna Hills, CA) and contact lens centration were measured. Right eye intraocular straylight measurements were collected (OCULUS C-Quant; Wetzlar, Germany) and compared with a spectacle trial lens. Log straylight (LogSL) values and straylight residuals were analyzed using repeated-measures analyses of variance with Tukey-corrected post hoc t -tests. RESULTS The mean participant age (±SD) was 24.1±1.5 years, and right eye spherical equivalent refractive error was -3.38±1.53 DS. There was no difference in mesopic pupil size between visits ( P =0.68) and no difference in contact lens centration between lenses ( P =0.99). LogSL values differed by lens type ( P =0.004). LogSL with the spectacle trial lens was significantly greater than with each contact lens type (all P <0.05), but there were no significant differences in LogSL between the three contact lenses (all P >0.05). There was no difference between the three contact lens designs for straylight residuals ( P =0.33). CONCLUSIONS Measured intraocular straylight for both MFCLs was not different than with a spherical soft contact lens. A significant increase in intraocular straylight with spectacle trial lens correction was observed compared with all contact lenses.
Collapse
|
3
|
Ticak A, Walline JJ, Berntsen DA, Mutti DO, Jones-Jordan LA, Cardenas L, Day E, Dougherty BE. Quality of life after wearing multifocal contact lenses for myopia control for 2 weeks in the BLINK Study. Ophthalmic Physiol Opt 2023; 43:1491-1499. [PMID: 37609711 PMCID: PMC10592163 DOI: 10.1111/opo.13216] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2023] [Revised: 08/02/2023] [Accepted: 08/04/2023] [Indexed: 08/24/2023]
Abstract
PURPOSE To validate Pediatric Refractive Error Profile 2 (PREP2) subscales that can be used to evaluate contact lens wearers and compare vision-specific quality of life measurements between children wearing multifocal and single vision contact lenses for 2 weeks. METHODS Two hundred and ninety-four myopic children aged 7-11 years (inclusive) were enrolled in the 3-year, double-masked Bifocal Lenses In Nearsighted Kids (BLINK) Study. Participants completed the PREP2 survey after having worn contact lenses for 2 weeks. The Vision, Symptoms, Activities and Overall PREP2 subscales were used to compare participants' subjective assessment while wearing +1.50 or +2.50 D add multifocal or single vision contact lenses. Rasch analysis was used to validate each subscale and to compare participants' subjective assessment of contact lens wear. RESULTS Item fit to the Rasch model was good for all scales, with no individual items having infit mean square statistics outside the recommended range (0.7-1.3). Response category function was acceptable for all subscales, with ordered category thresholds. Measurement precision, assessed by the Rasch person reliability statistic, was less than ideal (≥0.8) for three of the subscales, but met the minimum acceptable standard of 0.5. Scores for the Vision subscale differed by treatment assignment (p = 0.03), indicating that participants with the highest add power reported statistically worse quality of vision, although the difference was only 3.9 units on a scale of 1-100. Girls reported fewer symptoms than boys (p = 0.006), but there were no other differences between boys and girls. CONCLUSIONS Rasch analysis demonstrates that the PREP2 survey is a valid instrument for assessing refractive error-specific quality of life. These results suggest that vision-related quality of life is not meaningfully affected by 2 weeks of soft multifocal contact lens wear for myopia control.
Collapse
Affiliation(s)
- Anita Ticak
- University of Houston College of Optometry; Houston, Texas. USA
| | | | | | - Donald O. Mutti
- The Ohio State University College of Optometry; Columbus, Ohio, USA
| | | | - Laura Cardenas
- University of Houston College of Optometry; Houston, Texas. USA
| | - Elizabeth Day
- The Ohio State University College of Optometry; Columbus, Ohio, USA
| | | | | |
Collapse
|
4
|
Han D, Zhang Z, Li B, Rong H, Song D, Du B, Wei R. Comparison of visual performance and image quality between a myopia-control contact lens and a single-vision contact lens. Cont Lens Anterior Eye 2023; 46:101891. [PMID: 37574330 DOI: 10.1016/j.clae.2023.101891] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2023] [Revised: 07/14/2023] [Accepted: 07/16/2023] [Indexed: 08/15/2023]
Abstract
OBJECTIVE This study aimed to evaluate the visual performance and image quality of concentric dual-focus-designed contact lenses (CLs) compared with single-vision CLs in myopic Chinese people. METHODS Twenty myopic volunteers aged between 18 and 26 years were recruited at a university eye hospital to wear both defocus-incorporated soft contact (DISC) lenses and single-vision CLs for 1 week in random order. High- and low-contrast visual acuity (VA), contrast sensitivity (CS), ocular higher-order aberrations (HOA), Strehl ratio and the Quality of Vision (QoV) questionnaire were assessed with each type of CL at weekly follow-up. RESULTS Distance VA was not affected by DISC lenses compared to single-vision CLs in either high (p = 0.414) or low contrast (p = 0.431). However, there was a significant reduction in low-contrast near VA with DISC lenses compared with single-vision CLs (p = 0.011). The differences of CS between DISC lenses and single-vision CLs were significantly associated with lighting conditions and spatial frequencies (F = 128.81, P < 0.001). Compared with single-vision CLs, wavefront aberrations of DISC lenses were significantly increased in total HOA, trefoil, and spherical aberrations for either 3.0 mm or 6.0 mm pupil size. The Strehl ratio wearing DISC lenses reduced significantly compared to the single-vision CLs (p < 0.001) at a pupil diameter of 6.0 mm. QoV scores were higher overall (p = 0.026) and frequency (p = 0.019) with DISC lenses than with single-vision CLs, indicating poorer visual performance. CONCLUSION DISC lenses provide satisfactory distance VA. However, the higher scores of the QoV questionnaire with DISC lenses may be related to decreased CS at medium or high spatial frequencies and increased higher-order aberrations.
Collapse
Affiliation(s)
- Ding Han
- Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin 300384, China
| | - Ziyu Zhang
- Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin 300384, China
| | - Bingqin Li
- Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin 300384, China
| | - Hua Rong
- Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin 300384, China
| | - Desheng Song
- Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin 300384, China
| | - Bei Du
- Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin 300384, China
| | - Ruihua Wei
- Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin 300384, China.
| |
Collapse
|
5
|
Amorim-de-Sousa A, Pauné J, Silva-Leite S, Fernandes P, Gozález-Méijome JM, Queirós A. Changes in Choroidal Thickness and Retinal Activity with a Myopia Control Contact Lens. J Clin Med 2023; 12:jcm12113618. [PMID: 37297813 DOI: 10.3390/jcm12113618] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2023] [Revised: 05/15/2023] [Accepted: 05/19/2023] [Indexed: 06/12/2023] Open
Abstract
PURPOSE The axial elongation in myopia is associated with some structural and functional retinal changes. The purpose of this study was to investigate the effect of a contact lens (CL) intended for myopia control on the choroidal thickness (ChT) and the retinal electrical response. METHODS Ten myopic eyes (10 subjects, 18-35 years of age) with spherical equivalents from -0.75 to -6.00 diopters (D) were enrolled. The ChT at different eccentricities (3 mm temporal, 1.5 mm temporal, sub-foveal ChT, 1.5 mm nasal, and 3 mm nasal), the photopic 3.0 b-wave of ffERG and the PERG were recorded and compared with two material-matched contact lenses following 30 min of wear: a single-vision CL (SV) and a radial power gradient CL with +1.50 D addition (PG). RESULTS Compared with the SV, the PG increased the ChT at all eccentricities, with statistically significant differences at 3.0 mm temporal (10.30 ± 11.51 µm, p = 0.020), in sub-foveal ChT (17.00 ± 20.01 µm, p = 0.025), and at 1.5 mm nasal (10.70 ± 14.50 µm, p = 0.044). The PG decreased significantly the SV amplitude of the ffERG photopic b-wave (11.80 (30.55) µV, p = 0.047), N35-P50 (0.90 (0.96) µV, p = 0.017), and P50-N95 (0.46 (2.50) µV, p = 0.047). The amplitude of the a-wave was negatively correlated with the ChT at 3.0T (r = -0.606, p = 0.038) and 1.5T (r = -0.748, p = 0.013), and the amplitude of the b-wave showed a negative correlation with the ChT at 1.5T (r = -0.693, p = 0.026). CONCLUSIONS The PG increased the ChT in a similar magnitude observed in previous studies. These CLs attenuated the amplitude of the retinal response, possibly due to the combined effect of the induced peripheral defocus high-order aberrations impacting the central retinal image. The decrease in the response of bipolar and ganglion cells suggests a potential retrograde feedback signaling effect from the inner to outer retinal layers observed in previous studies.
Collapse
Affiliation(s)
- Ana Amorim-de-Sousa
- Clinical and Experimental Optometry Research Lab (CEORLab), School of Science, University of Minho, 4710-057 Braga, Portugal
| | - Jaume Pauné
- Teknon Medical Center, 08022 Barcelona, Spain
- Faculty of Optics and Optometry Polytechnic, University of Catalonia, 08222 Terrassa, Spain
| | - Sara Silva-Leite
- Clinical and Experimental Optometry Research Lab (CEORLab), School of Science, University of Minho, 4710-057 Braga, Portugal
| | - Paulo Fernandes
- Clinical and Experimental Optometry Research Lab (CEORLab), School of Science, University of Minho, 4710-057 Braga, Portugal
- Physics Center of Minho and Porto Universities, CF-UM-UP, 4710-057 Braga, Portugal
| | - José Manuel Gozález-Méijome
- Clinical and Experimental Optometry Research Lab (CEORLab), School of Science, University of Minho, 4710-057 Braga, Portugal
- Physics Center of Minho and Porto Universities, CF-UM-UP, 4710-057 Braga, Portugal
| | - António Queirós
- Clinical and Experimental Optometry Research Lab (CEORLab), School of Science, University of Minho, 4710-057 Braga, Portugal
- Physics Center of Minho and Porto Universities, CF-UM-UP, 4710-057 Braga, Portugal
| |
Collapse
|
6
|
Zhang J, Zheng L, Zhang Y, Wang K. Analysis of Asphericity and Corneal Longitudinal Spherical Aberration of 915 Chinese Myopic Adult Eyes. Clin Ophthalmol 2023; 17:591-600. [PMID: 36814783 PMCID: PMC9939669 DOI: 10.2147/opth.s404437] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2023] [Accepted: 02/09/2023] [Indexed: 02/16/2023] Open
Abstract
Purpose To analyze the corneal asphericity, longitudinal spherical aberration (LSA), and related factors in Chinese myopic adult eyes. Methods This was a retrospective study of myopic adult patients. The corneal asphericity and LSA were measured at 3.0, 4.0, 5.0, 6.0, and 7.0 mm diameter apertures using corneal tomography. Age and refractive power were recorded for correlation analysis. Results In total, 531 females and 384 males were included. At the above five diameter settings the corneal asphericity values (Q) of the anterior surface were -0.09±0.21, -0.14±0.16, -0.15±0.13, -0.17±0.11, and -0.20±0.11, and those of the posterior surface were 0.23±0.49, 0.06±0.29, -0.01±0.22, -0.07±0.16, and -0.08±0.15, respectively. The anterior corneal LSA values at these diameters were 0.39±0.19, 0.63±0.27, 0.97±0.36, 0.90±0.30, and 0.83±0.29 D, respectively and the whole corneal values were 0.26±0.20, 0.44±0.27, 0.70±0.36, 0.66±0.30, and 0.59±0.28 D, respectively. Corneal asphericity and peripheral LSA showed no or weak correlation with age or spherical equivalent (all r < 0.2). Conclusion Corneal anterior and posterior Q values in myopia patients are negatively correlated with corneal diameter. Corneal anterior and whole corneal LSA increased significantly with diameter up to 5 mm, then decreased slightly with diameter. Corneal asphericity and peripheral LSA showed very weak or no correlation with age or spherical equivalent. Clinical Trial Registration Number ChiCTR1800015985.
Collapse
Affiliation(s)
- Jun Zhang
- Department of Ophthalmology, Hangzhou MSK Eye Hospital, Hangzhou, People’s Republic of China,Correspondence: Jun Zhang, Department of Ophthalmology, Hangzhou MSK Eye Hospital, Hangzhou, People’s Republic of China, Tel +86-18667046602; +86-0571 85064148, Email
| | - Li Zheng
- Department of Ophthalmology, Hangzhou MSK Eye Hospital, Hangzhou, People’s Republic of China
| | - Yixuan Zhang
- Department of Ophthalmology, Hangzhou MSK Eye Hospital, Hangzhou, People’s Republic of China
| | - Ke Wang
- Department of Ophthalmology, Hangzhou MSK Eye Hospital, Hangzhou, People’s Republic of China
| |
Collapse
|
7
|
García-Marqués JV, Macedo-De-Araújo RJ, McAlinden C, Faria-Ribeiro M, Cerviño A, González-Méijome JM. Short-term tear film stability, optical quality and visual performance in two dual-focus contact lenses for myopia control with different optical designs. Ophthalmic Physiol Opt 2022; 42:1062-1073. [PMID: 35801815 PMCID: PMC9540637 DOI: 10.1111/opo.13024] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2022] [Revised: 06/20/2022] [Accepted: 06/20/2022] [Indexed: 12/14/2022]
Abstract
Purpose To assess and compare short‐term visual and optical quality and tear film stability between two dual‐focus (DF) prototype myopia control contact lenses (CLs) having different inner zone diameters. Methods Twenty‐eight myopic subjects were included in this randomised, double‐masked crossover study. Refraction, best‐corrected visual acuity (VA) and tear film stability were measured at baseline (i.e., when uncorrected). Subjects were then binocularly fitted with the DF CLs, with only the sensorial dominant eye being assessed. Lenses were of the same material and had inner zone diameters of either 2.1 mm (S design) or 4.0 mm (M design). Visual and physical short‐term lens comfort, over‐refraction, best‐corrected VA, stereopsis at 40 cm, best‐corrected photopic and mesopic contrast sensitivity (CS), size and shape of light disturbance (LD), wavefront aberrations, subjective quality of vision (QoV Questionnaire) and tear film stability were measured for each lens. Results Both CL designs decreased tear film stability compared with baseline (p < 0.05). VA and photopic CS were within normal values for the subjects' age with each CL. When comparing lenses, the M design promoted better photopic CS for the 18 cycles per degree spatial frequency (p < 0.001) and better LD (p < 0.02). However, higher‐order aberrations were improved with the S design (p = 0.02). No significant difference between the two CLs was found for QoV scores and tear film stability. Conclusions Both DF CLs provided acceptable visual performance under photopic conditions. The 4.0 mm inner zone gave better contrast sensitivity at high frequencies and lower light disturbance, while the 2.1 mm central diameter induced fewer higher‐order aberrations for a 5 mm pupil diameter. Both CLs produced the same subjective visual short‐term lens comfort.
Collapse
Affiliation(s)
- José Vicente García-Marqués
- Optometry Research Group, Department of Optics and Optometry and Vision Sciences, University of Valencia, Valencia, Spain
| | - Rute Juliana Macedo-De-Araújo
- Clinical and Experimental Optometry Research Laboratory (CEORLab) Center of Physics (Optometry), School of Sciences, University of Minho, Braga, Portugal
| | - Colm McAlinden
- Department of Ophthalmology, Royal Gwent Hospital, Newport, UK.,Wenzhou Medical University, Wenzhou, China.,Eye & ENT Hospital of Fudan University, Shanghai, China
| | - Miguel Faria-Ribeiro
- Clinical and Experimental Optometry Research Laboratory (CEORLab) Center of Physics (Optometry), School of Sciences, University of Minho, Braga, Portugal
| | - Alejandro Cerviño
- Optometry Research Group, Department of Optics and Optometry and Vision Sciences, University of Valencia, Valencia, Spain
| | - José Manuel González-Méijome
- Clinical and Experimental Optometry Research Laboratory (CEORLab) Center of Physics (Optometry), School of Sciences, University of Minho, Braga, Portugal
| |
Collapse
|
8
|
Chen ST, Tung HC, Chen YT, Tien CL, Yeh CW, Lian JS, Cheng CY. The influence of contact lenses with different optical designs on the binocular vision and visual behavior of young adults. Sci Rep 2022; 12:6573. [PMID: 35449200 PMCID: PMC9023515 DOI: 10.1038/s41598-022-10580-7] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2022] [Accepted: 04/11/2022] [Indexed: 11/10/2022] Open
Abstract
Theoretically, contact lenses change the accommodation and vergence demands of the eyes and directly or indirectly influence binocular vision. The purpose of this study was to investigate the influence of different optical designs of contact lenses on binocular vision and visual behavior among young adults. In this randomized, single-blinded experimental study, visual behavioral performance (VBP) and Ocular Surface Disease Index questionnaires were used for preliminary screening. Nineteen myopic subjects aged 20-26 years (21.59 ± 1.40 years) participated in the study. Baseline values for subjective refraction and binocular visual functions were evaluated. All the subjects were randomly grouped to wear different optical designs of single-vision, progressive, and bifocal contact lenses. Eye examinations were performed on the first day (CL baseline), 2nd week, and 4th week of wearing the lenses. In addition, subjects completed the VBP and visual quality questionnaire again at the end of the examination. Single-vision contact lenses (Lens 1) increased accommodative lag, negative relative accommodation, and distant and near vergence; however, vergence facilities, accommodative facilities, heterophoria, and the comfort and posture balance dimensions in the VBP questionnaire were improved. Progressive contact lenses (Lens 2) reduced the lag of accommodation and near vergence; in addition, vergence facilities and accommodative facilities were also improved. Bifocal contact lenses (Lens 3) affected negative and positive relative accommodation, but vergence facilities and accommodative facilities also progressed. Furthermore, both progressive (Lens 2) and bifocal (Lens 3) contact lenses enhanced overall visual behavioral performance. In terms of visual quality, single-vision contact lenses (Lens 1) were the most comfortable, progressive and bifocal contact lenses reduced distant visual acuity and stability, progressive contact lenses (Lens 2) had more complaints about halos at night, and bifocal contact lens (Lens 3) users were more likely to have double vision. Compared with single-vision contact lenses, progressive and bifocal contact lenses relaxed accommodation, reduced the lag of accommodation, and improved visual behavioral performance. Although the vergence function showed a significant change, it did not show worse trends when wearing contact lenses. Contact lenses with different optical designs have a great influence on binocular vision and visual behavioral performance.
Collapse
Affiliation(s)
- Shyan-Tarng Chen
- Department of Optometry, Chung Shan Medical University, Taichung, Taiwan.,Department of Ophthalmology, Chung Shan Medical University Hospital, Taichung, Taiwan
| | | | - Yan-Ting Chen
- Department of Ophthalmology, Chung Shan Medical University Hospital, Taichung, Taiwan
| | - Chuen-Lin Tien
- Department of Electrical Engineering, Feng Chia University, Taichung, Taiwan
| | - Chih-Wei Yeh
- Department of Optometry, Chung Shan Medical University, Taichung, Taiwan
| | - Jheng-Sin Lian
- Shu-Zen Junior College of Medicine and Management, Kaohsiung, Taiwan
| | - Ching-Ying Cheng
- Department of Optometry, Chung Shan Medical University, Taichung, Taiwan. .,Department of Ophthalmology, Chung Shan Medical University Hospital, Taichung, Taiwan.
| |
Collapse
|
9
|
Nti AN, Gregory HR, Ritchey ER, Wolffsohn JS, Berntsen DA. Contrast Sensitivity with Center-distance Multifocal Soft Contact Lenses. Optom Vis Sci 2022; 99:342-349. [PMID: 35121719 PMCID: PMC8986568 DOI: 10.1097/opx.0000000000001874] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
SIGNIFICANCE The contrast sensitivity (CS) function provides a more detailed assessment of vision than visual acuity. It was found that center-distance multifocal contact lens designs that are increasingly being prescribed for myopia control reduce distance photopic and mesopic CS in nonpresbyopic patients across a range of spatial frequencies. PURPOSE This study aimed to determine the effect of center-distance multifocal soft contact lenses (MFCLs) on CS under photopic and mesopic conditions in nonpresbyopic patients. METHODS Twenty-five myopic, nonpresbyopic adults were fitted binocularly with three lenses: Biofinity single vision contact lens (SVCL), Biofinity Multifocal D +2.50 add, and NaturalVue Multifocal in random order. Contrast sensitivity was measured at distance (4 m) under photopic and mesopic conditions and at near under photopic conditions. Log CS by spatial frequency and area under the log contrast sensitivity function (AULCSF) were analyzed between lenses. RESULTS Distance photopic CS at each spatial frequency was higher with the SVCL than the MFCLs (P < .001), but there was no difference between the MFCLs (P = .71). Distance mesopic CS from 1.5 to 12 cycles per degree (cpd) was higher with the SVCL than the MFCLs (all P < .02); however, at 18 cpd, there was no difference in CS between NaturalVue and the SVCL (P = .76), possibly because of spurious resolution. Photopic AULCSF for the SVCL was roughly 10% greater than both MFCLs. Contrast sensitivity at near was generally similar between lenses, only slightly lower with the NaturalVue at 11 and 15.5 cpd, but AULCSF at near was not different between lenses (P > .05). CONCLUSIONS Multifocal contact lenses reduce distance contrast sensitivity under both photopic and mesopic conditions. There is no clinically significant difference in near CS among all three lenses. These data show that MFCLs have effects on vision that are not captured by standard high-contrast visual acuity testing.
Collapse
Affiliation(s)
| | - Hannah R Gregory
- The Ocular Surface Institute, University of Houston College of Optometry, Houston, Texas
| | - Eric R Ritchey
- The Ocular Surface Institute, University of Houston College of Optometry, Houston, Texas
| | - James S Wolffsohn
- Optometry and Vision Science Research Group, College of Health and Life Sciences, Aston University, Birmingham, United Kingdom
| | - David A Berntsen
- The Ocular Surface Institute, University of Houston College of Optometry, Houston, Texas
| |
Collapse
|
10
|
Redondo B, Vera J, Molina R, Galán T, Machado P, Jiménez R. Changes in accommodation and behavioural performance with a contact lens for myopia management: A comparison between a dual-focus and a single-vision soft contact lens. Ophthalmic Physiol Opt 2022; 42:753-761. [PMID: 35305040 PMCID: PMC9313609 DOI: 10.1111/opo.12978] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2021] [Revised: 02/18/2022] [Accepted: 02/18/2022] [Indexed: 12/02/2022]
Abstract
Introduction Dual‐focus soft contact lenses for myopia management have demonstrated to be an effective strategy to reduce myopia progression. However, this optical design has been shown to alter visual quality and accommodative function. The aim of this study was to examine the accommodative and behavioural performance during the execution of a psychomotor vigilance task (PVT) while wearing dual‐focus and single‐vision soft contact lenses. Methods The steady‐state accommodative response was recorded with the WAM‐5500 binocular open‐field autorefractor during the execution of a 10‐min PVT at 50 cm either with the dual‐focus (MiSight 1‐day) or single‐vision (Proclear 1‐day) soft contact lenses, using a sample of 23 healthy young adults. Each experimental session was performed on two different days in a counterbalanced order. Results A greater lag of accommodation, variability of accommodation and reaction time was found while wearing dual‐focus in comparison with single‐vision soft contact lenses (mean differences during the 10‐min PVT were 0.58 ± 0.81 D, p < 0.001; 0.31 ± 0.17 D, p < 0.001 and 15.22 ± 20.93 ms, p = 0.002, respectively). Also, a time‐on‐task effect was found for the variability of accommodation and reaction time (p = 0.001 and p < 0.001, respectively), observing higher values over time. However, the lag of accommodation did not change significantly as a function of time‐on‐task (p = 0.33). Conclusion Dual‐focus soft contact lens wear influences the steady‐state accommodative response and behavioural performance during the execution of a visual vigilance task in the short‐term. Eye care practitioners should be aware of these effects when prescribing these lenses for myopia management, and provide specific recommendations according to the individual visual needs.
Collapse
Affiliation(s)
- Beatriz Redondo
- CLARO (Clinical and Laboratory Applications of Research in Optometry) Research Group, Department of Optics, Faculty of Sciences, University of Granada, Granada, Spain
| | - Jesús Vera
- CLARO (Clinical and Laboratory Applications of Research in Optometry) Research Group, Department of Optics, Faculty of Sciences, University of Granada, Granada, Spain
| | - Rubén Molina
- CLARO (Clinical and Laboratory Applications of Research in Optometry) Research Group, Department of Optics, Faculty of Sciences, University of Granada, Granada, Spain
| | - Tomás Galán
- CLARO (Clinical and Laboratory Applications of Research in Optometry) Research Group, Department of Optics, Faculty of Sciences, University of Granada, Granada, Spain
| | - Pedro Machado
- CLARO (Clinical and Laboratory Applications of Research in Optometry) Research Group, Department of Optics, Faculty of Sciences, University of Granada, Granada, Spain
| | - Raimundo Jiménez
- CLARO (Clinical and Laboratory Applications of Research in Optometry) Research Group, Department of Optics, Faculty of Sciences, University of Granada, Granada, Spain
| |
Collapse
|
11
|
Tomiyama ES, Hu C, Marsack JD, Richdale K. Greater higher order aberrations induced by toric orthokeratology versus soft toric multifocal contact lens wear. Ophthalmic Physiol Opt 2021; 41:726-735. [PMID: 34076904 PMCID: PMC8217292 DOI: 10.1111/opo.12839] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2021] [Accepted: 04/16/2021] [Indexed: 01/15/2023]
Abstract
PURPOSE Spherical orthokeratology and soft multifocal contact lenses are commonly used for myopia control and correction, but have been shown to increase spherical aberration, coma and total higher order root mean square (HORMS) aberrations. There are limited myopia control contact lens options for patients with moderate to high astigmatism. The purpose of this study was to quantify changes in higher order aberrations (HOA) in myopic astigmatic eyes fitted with toric orthokeratology (TOK) and soft toric multifocal (STM) contact lenses. METHODS Ocular wavefront aberrations were measured in both eyes of 30 adult subjects and are reported through the 6th radial order over a 5 mm, dilated pupil. All eyes met refractive criteria of myopia (-5.00 D to plano) and cylinder (-3.50 to -1.25 D). Three measurements were taken at baseline and after 10 ± 2 days of lens wear (TOK, STM). Sixteen subjects achieved logMAR high contrast visual acuity of 0.30 or better in both eyes and were included in this analysis. Repeated measures analysis of variance and post-hoc paired t-tests were used, as appropriate, with Benjamini-Hochberg correction. RESULTS Higher order root mean square, spherical aberration (C12), and coma RMS (C7, C8) increased with TOK (0.641 [0.222], 0.409 [0.157], 0.426 [0.187] µm, respectively) and STM (0.481 [0.107], 0.223 [0.139], 0.320 [0.130] µm, respectively) from baseline (all p < 0.001). TOK was elevated compared to STM for HORMS (p = 0.03), spherical aberration (p = 0.001) and coma RMS (p = 0.04). CONCLUSIONS Toric orthokeratology induced more HORMS, spherical aberration and coma RMS than STM in myopic astigmats; however, both lens types showed an increase in HOA compared to baseline, which placed patients outside the age and pupil size matched normative ranges. While the optical changes that accompany these modalities are helpful for myopia management, the induction of HOAs may have unintended consequences on visual performance.
Collapse
Affiliation(s)
- Erin S Tomiyama
- University of Houston College of Optometry, Houston, Texas, USA
| | - Chuan Hu
- University of Houston College of Optometry, Houston, Texas, USA
| | - Jason D Marsack
- University of Houston College of Optometry, Houston, Texas, USA
| | | |
Collapse
|
12
|
García-Marqués JV, Macedo-de-Araújo R, Lopes-Ferreira D, Cerviño A, García-Lázaro S, González-Méijome JM. Tear film stability over a myopia control contact lens compared to a monofocal design. Clin Exp Optom 2021; 105:41-47. [PMID: 33689656 DOI: 10.1080/08164622.2021.1878864] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022] Open
Abstract
Clinical relevance: Tear film assessment is essential in contact lens wearers and it can improve the success rates of the fitting.Background: To compare the short-term effect of two contact lenses on pre-lens tear film stability and comfort: dual-focus contact lens (MiSight) and a monofocal contact lens (Proclear 1-day).Methods: This randomised, double-masked, crossover study was performed in twenty-eight healthy, myopic volunteers aged between 18 and 32 years (23.5 ± 4.1 years). Only one randomly chosen eye was assessed. Distance vision and refraction were evaluated at baseline. Each contact lens type (monofocal and dual-focus) was randomly fitted, always in both eyes. A visual analogue scale between 0 and 10 was used to assess general comfort, physical comfort, and visual comfort. Tear Film Surface Quality (TFSQ) index, TFSQ_area and auto Tear Break-Up Time were obtained using Medmont E-300 at baseline (naked eye condition) and 25 minutes after each contact lens insertion.Results: Refractive sphere and cylinder were, respectively, -1.36 ± 1.04 D (ranging from -6.00 to -0.25 D) and -0.23 ± 0.30 D (ranging from -0.75 to 0.00 D). TFSQ and TFSQ area were lower (meaning more stable tear film) at baseline when compared with both contact lens types (p < 0.025). Higher pre-lens tear instability (larger TFSQ and_TFSQ area values) was found with the dual-focus than the monofocal lens. Auto Tear Break-Up Time was higher at baseline than with each of the contact lenses, without statistically significant differences between both contact lens types. Visual analogue scales revealed statistically significant better scores in the monofocal contact lens than in dual-focus contact lens for general (0.77 ± 1.14 vs 3.12 ± 2.79), physical (0.96 ± 1.46 vs 2.19 ± 2.45) and visual comfort (1.27 ± 1.66 vs 3.92 ± 2.04).Conclusion: A slight reduction in short-term pre-lens tear film stability was found in the dual-focus design in comparison with the monofocal lens, potentially contributing to the deterioration of visual performance and comfort during dual-focus contact lens wear.
Collapse
Affiliation(s)
| | - Rute Macedo-de-Araújo
- Clinical and Experimental Optometry Research Laboratory (CEORLab) Center of Physics (Optometry), University of Minho, Braga, Portugal
| | - Daniela Lopes-Ferreira
- Clinical and Experimental Optometry Research Laboratory (CEORLab) Center of Physics (Optometry), University of Minho, Braga, Portugal
| | - Alejandro Cerviño
- Department of Optics and Optometry and Vision Sciences, University of Valencia, Burjassot, Spain
| | - Santiago García-Lázaro
- Department of Optics and Optometry and Vision Sciences, University of Valencia, Burjassot, Spain
| | - José Manuel González-Méijome
- Clinical and Experimental Optometry Research Laboratory (CEORLab) Center of Physics (Optometry), University of Minho, Braga, Portugal
| |
Collapse
|
13
|
Lopes-Ferreira D, Ruiz-Pomeda A, Peréz-Sanchéz B, Queirós A, Villa-Collar C. Ocular and corneal aberrations changes in controlled randomized clinical trial MiSight® Assessment Study Spain (MASS). BMC Ophthalmol 2021; 21:112. [PMID: 33648464 PMCID: PMC7919067 DOI: 10.1186/s12886-021-01865-y] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2020] [Accepted: 02/12/2021] [Indexed: 12/22/2022] Open
Abstract
Background To compare ocular and corneal inherent aberrations in the naked eyes of randomly selected children fitted with MiSight contact lenses (CL) for myopia control, versus children corrected with single-vision spectacles (control), over a 24-months period. Methods Children aged 8 to 12 years, with myopia (-0.75 to -4.00 D sphere) and astigmatism (< -1.00 D cylinder) were randomly assigned to the lens study group (MiSight) or the control group (single-vision spectacles). The root mean square aberration (RMS) was determined as corneal (RMS_C), corneal high order RMS (HO_RMS_C), corneal low order RMS (LO_RMS_C), ocular (total) RMS (RMS_T), ocular high order RMS (HO_RMS_T), ocular low order RMS (LO_RMS_T), corneal spherical aberration (SA_C) and ocular SA (SA_T) were calculated by aberrometry measures at the baseline, on 12-months and 24-months visits. A 5 mm diameter was defined for the analysis in all visits for all subjects. Only the dominant eye was analyzed. Results Seventy-four subjects completed the clinical trial: 41 subjects from the MiSight group (age: 11.01 ± 1.23 years) and 33 from the single-vision group (age: 10.12 ± 1.38 years). RMS_T significantly changed (0.57 ± 0.20 µm, p = 0.029) after 24-months in the control group. In the MiSight group no significant changes were registered (p > 0.05). The SA_C and SA_T did not reveal significant changes between visits or between groups (p > 0.05). Conclusions Along 2 years, MiSight CL did not induce significant changes in RMS of anterior cornea or total ocular RMS. Contrary, in control group the RMS_T significantly changed as response of greater eye growth and myopia progression. The results obtained in present study allow to predict corneal or total aberration changes, in children, in response of wearing of MiSight lens along the time. Trial registration : ClinicalTrials.gov Identifier: NCT01917110.
Collapse
Affiliation(s)
- Daniela Lopes-Ferreira
- CEORLab, Centre of Physics, Clinical and Experimental Optometry Research Lab, University of Minho, Campus de Gualtar, 4710-057, Braga, Portugal.
| | - Alicia Ruiz-Pomeda
- Servicio de Oftalmología. Hospital Universitario de Mostoles, Mostoles, Madrid, Spain
| | - Belén Peréz-Sanchéz
- Department of Statistics, Mathematics and Informatics, Area of Languages and Computer Systems, Miguel Hernández University of Elche, Elche, Alicante, Spain
| | - António Queirós
- CEORLab, Centre of Physics, Clinical and Experimental Optometry Research Lab, University of Minho, Campus de Gualtar, 4710-057, Braga, Portugal
| | - César Villa-Collar
- Department of Pharmacy, Biotechnology, Optics and Optometry, European University of Madrid, C/Tajo s/n, 28670, Villaviciosa de Odón, Madrid, Spain
| |
Collapse
|
14
|
García‐Marqués JV, Macedo‐De‐Araújo RJ, Cerviño A, García‐Lázaro S, McAlinden C, González‐Méijome JM. Comparison of short‐term light disturbance, optical and visual performance outcomes between a myopia control contact lens and a single‐vision contact lens. Ophthalmic Physiol Opt 2020; 40:718-727. [DOI: 10.1111/opo.12729] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2020] [Accepted: 07/27/2020] [Indexed: 12/13/2022]
Affiliation(s)
- José Vicente García‐Marqués
- Optometry Research Group Department of Optics and Optometry and Vision Sciences University of Valencia Valencia Spain
| | - Rute Juliana Macedo‐De‐Araújo
- Clinical and Experimental Optometry Research Laboratory (CEORLab) Center of Physics (Optometry) School of Sciences University of Minho Braga Portugal
| | - Alejandro Cerviño
- Optometry Research Group Department of Optics and Optometry and Vision Sciences University of Valencia Valencia Spain
| | - Santiago García‐Lázaro
- Optometry Research Group Department of Optics and Optometry and Vision Sciences University of Valencia Valencia Spain
| | - Colm McAlinden
- Department of Ophthalmology Singleton HospitalSwansea Bay University Health Board Swansea UK
- Wenzhou Medical University Wenzhou China
| | - Jose Manuel González‐Méijome
- Clinical and Experimental Optometry Research Laboratory (CEORLab) Center of Physics (Optometry) School of Sciences University of Minho Braga Portugal
| |
Collapse
|
15
|
Bifocal and Multifocal Contact Lenses for Presbyopia and Myopia Control. J Ophthalmol 2020; 2020:8067657. [PMID: 32318285 PMCID: PMC7152962 DOI: 10.1155/2020/8067657] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2019] [Revised: 02/10/2020] [Accepted: 02/24/2020] [Indexed: 02/07/2023] Open
Abstract
Bifocal and multifocal optical devices are intended to get images into focus from objects placed at different distances from the observer. Spectacles, contact lenses, and intraocular lenses can meet the requirements to provide such a solution. Contact lenses provide unique characteristics as a platform for implementing bifocality and multifocality. Compared to spectacles, they are closer to the eye, providing a wider field of view, less distortion, and their use is more consistent as they are not so easily removed along the day. In addition, contact lenses are also minimally invasive, can be easily exchangeable, and, therefore, suitable for conditions in which surgical procedures are not indicated. Contact lenses can remain centered with the eye despite eye movements, providing the possibility for simultaneous imaging from different object distances. The main current indications for bifocal and multifocal contact lenses include presbyopia correction in adult population and myopia control in children. Considering the large numbers of potential candidates for optical correction of presbyopia and the demographic trends in myopia, the potential impact of contact lenses for presbyopia and myopia applications is undoubtedly tremendous. However, the ocular characteristics and expectations vary significantly between young and older candidates and impose different challenges in fitting bifocal and multifocal contact lenses for the correction of presbyopia and myopia control. This review presents the recent developments in material platforms, optical designs, simulated visual performance, and the clinical performance assessment of bifocal and multifocal contact lenses for presbyopia correction and/or myopia progression control.
Collapse
|