1
|
Orhan ZD, Ciğerim L. Evaluation of Effect of Different Insertion Speeds and Torques on Implant Placement Condition and Removal Torque in Polyurethane Dense D1 Bone Model. Polymers (Basel) 2024; 16:1361. [PMID: 38794554 PMCID: PMC11125928 DOI: 10.3390/polym16101361] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2024] [Revised: 05/05/2024] [Accepted: 05/07/2024] [Indexed: 05/26/2024] Open
Abstract
The aim of this study was to evaluate the effect of two different insertion speeds at eight different insertion torque values ranging from 25 to 60 during implantation in a dense polyurethane (PU) D1 bone model on the placement condition and removal torque of dental implants. In this study, 50 pcf single-layer PU plates were used. In the study, a total of 320 implant sockets were divided into two groups, Group 1 (30 rpm) and Group 2 (50 rpm), in terms of insertion speed. Group 1 and Group 2 were divided into eight subgroups with 25, 30, 35, 40, 45, 50, 55 and 60 torques. There were 20 implant sockets in each subgroup. During the implantations, the implant placement condition and removal torque values were assessed. There was a statistically significant difference between the 30 and 50 rpm groups in terms of overall implant placement condition (p < 0.01). It was found that the removal torque values at 50 rpm were statistically significantly higher than those at 30 rpm (p < 0.01). This study showed that in dense D1 bone, the minimum parameters at which all implants could be placed at the bone level were 50 torque at 30 rpm and 40 torque at 50 rpm.
Collapse
Affiliation(s)
| | - Levent Ciğerim
- Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Van Yuzuncu Yil University, Van 65090, Turkey;
| |
Collapse
|
2
|
Inchingolo AM, Dipalma G, Inchingolo AD, Palumbo I, Guglielmo M, Morolla R, Mancini A, Inchingolo F. Advancing Postoperative Pain Management in Oral Cancer Patients: A Systematic Review. Pharmaceuticals (Basel) 2024; 17:542. [PMID: 38675500 PMCID: PMC11054702 DOI: 10.3390/ph17040542] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2024] [Revised: 04/02/2024] [Accepted: 04/16/2024] [Indexed: 04/28/2024] Open
Abstract
The goal of this review is to shed light on the management of orofacial discomfort after a cancer diagnosis in the head and neck region. A search was conducted on PubMed, Scopus, and Web of Science to identify studies on postoperative pain control in oral cancer. The review included open-access research, investigations into pain management, randomized clinical trials, retrospective studies, case-control studies, prospective studies, English-written studies, and full-text publications. Exclusion criteria included animal studies; in vitro studies; off-topic studies; reviews, case reports, letters, or comments; and non-English language. Three reviewers independently accessed databases and assigned a quality rating to the chosen articles. The review explores postoperative pain management in oral cancer patients; highlighting persistent opioid use; the efficacy of adjuvant drugs, such as gabapentin; and a multimodal approach. It emphasizes the need for personalized pain management, recognizing individual pain perception and tailoring interventions. Integrating pharmacological and non-pharmacological strategies is crucial for comprehensive pain management. The review also serves as a guide for future research, emphasizing the need for standardized methodologies and diverse participant populations.
Collapse
Affiliation(s)
| | - Gianna Dipalma
- Correspondence: (G.D.); (F.I.); Tel.: +39-339-698-9939 (G.D.); +39-331-211-1104 (F.I.)
| | | | | | | | | | | | - Francesco Inchingolo
- Correspondence: (G.D.); (F.I.); Tel.: +39-339-698-9939 (G.D.); +39-331-211-1104 (F.I.)
| |
Collapse
|
3
|
Ramesh R, Sasi A, Mohamed SC, Joseph SP. "Compression Necrosis" - A Cause of Concern for Early Implant Failure? Case Report and Review of Literature. Clin Cosmet Investig Dent 2024; 16:43-52. [PMID: 38469322 PMCID: PMC10926919 DOI: 10.2147/ccide.s453798] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2023] [Accepted: 02/28/2024] [Indexed: 03/13/2024] Open
Abstract
Purpose Compression necrosis refers to bone tissue damage that can occur when excessive pressure or force is applied to surrounding bone during implant placement. This pressure can compromise blood supply to the bone, leading to necrosis. Compression necrosis is a concern, because it can affect the stability and long-term success of dental implant. Patients and Methods This case report highlights a case of early bone loss and implant failure possibly due to compression necrosis. Clinical data, photographs, radiographs, blood examination report and histology were presented to document the early failure of an implant placed in the mandibular left posterior region of a 33-year-old female patient. Results Radiograph taken six weeks after implant placement showed severe angular defect. Therefore, the implant was surgically removed. Histological examination of the area showed bony trabeculae with an absence of osteoblastic riming, suggestive of necrotic bone. Conclusion Using excessive torque values when placing implants in dense bones can increase the risk of implant failure due to bone over compression. Dental professionals must follow the manufacturer's instructions and employ quality surgical techniques during implant placement into dense cortical bone to minimise risks.
Collapse
Affiliation(s)
- Roshni Ramesh
- Department of Periodontology, Government Dental College, Thiruvananthapuram, Kerala, India
| | - Anoop Sasi
- Department of Periodontology, Government Dental College, Thiruvananthapuram, Kerala, India
| | - Shahana C Mohamed
- Department of Periodontology, Government Dental College, Thiruvananthapuram, Kerala, India
| | - Sonia P Joseph
- Department of Periodontology, Government Dental College, Thiruvananthapuram, Kerala, India
| |
Collapse
|
4
|
Ribes BL, Fernández-Baca I, Gil Mur J, López-Malla Matute J, Aragoneses Lamas JM. Autologous Tooth Granulometry and Specific Surface Area with Three Grinding Methods: An In Vitro Study. MATERIALS (BASEL, SWITZERLAND) 2024; 17:773. [PMID: 38399026 PMCID: PMC10890256 DOI: 10.3390/ma17040773] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/05/2023] [Revised: 01/15/2024] [Accepted: 02/02/2024] [Indexed: 02/25/2024]
Abstract
A postextraction socket becomes a clinical challenge due to the fact that a series of changes associated with bone remodelling and resorption of the socket that occur after extraction, which limits the aesthetic and functional prognosis of implant-supported rehabilitations. It has been studied that the use of the autologous tooth-derived graft (ATDG) has regenerative properties and could therefore be useful for solving this type of problem. There is no consensus in the scientific literature on a standardized protocol for the use of the autologous tooth. Therefore, the aim of the present study was to evaluate the most relevant parameters to achieve the best properties of ground ATDG using three methods, namely Gouge forceps, electric grinder, and manual, that made up the study group (SG) and compared with the control group (CG) consisting of Bio-Oss®. The sample obtained by the electric grinder had the highest value of specific surface area (2.4025 ± 0.0218 m2/g), while the particle size as average diameter (751.9 µm) was the lowest and most homogeneous of the three groups. Therefore, the electric grinder allowed for obtaining ATDG with more regenerative properties due to its specific surface-area value and particle size in accordance with the xenograft with the greatest bibliographical support (Bio-Oss®). The higher specific surface increases the reaction with the physiological media, producing faster biological mechanisms.
Collapse
Affiliation(s)
- Berta Lavarias Ribes
- Bioengineering Institute of Technology, Faculty of Medicine and Health Sciences, International University of Catalonia, Sant Cugat del Vallés, 08195 Barcelona, Spain; (B.L.R.); (I.F.-B.); (J.G.M.)
- Faculty of Dentistry, Universidad Alfonso X El Sabio, 28037 Madrid, Spain;
| | - Ignacio Fernández-Baca
- Bioengineering Institute of Technology, Faculty of Medicine and Health Sciences, International University of Catalonia, Sant Cugat del Vallés, 08195 Barcelona, Spain; (B.L.R.); (I.F.-B.); (J.G.M.)
- Faculty of Dentistry, Universidad Alfonso X El Sabio, 28037 Madrid, Spain;
| | - Javier Gil Mur
- Bioengineering Institute of Technology, Faculty of Medicine and Health Sciences, International University of Catalonia, Sant Cugat del Vallés, 08195 Barcelona, Spain; (B.L.R.); (I.F.-B.); (J.G.M.)
| | | | - Juan Manuel Aragoneses Lamas
- Faculty of Dentistry, Universidad Alfonso X El Sabio, 28037 Madrid, Spain;
- Department of Dental Research, Federico Henriquez y Carvajal University, Santo Domingo 11005, Dominican Republic
| |
Collapse
|
5
|
Romasco T, Pignatelli P, Tumedei M, Hossein HHS, Cipollina A, Piattelli A, Inchingolo F, Di Pietro N. The influence of truncated-conical implant length on primary stability in maxillary and mandibular regions: an in vitro study using polyurethane blocks. Clin Oral Investig 2023; 28:28. [PMID: 38147179 DOI: 10.1007/s00784-023-05444-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2023] [Accepted: 12/17/2023] [Indexed: 12/27/2023]
Abstract
OBJECTIVES This in vitro study is aimed at assessing whether implant primary stability is influenced by implant length in artificial bone with varying densities. MATERIALS AND METHODS A total of 120 truncated-conical implants (60 long-length: 3p L, 3.8 × 14 mm; 60 short-length: 3p S, 3.8 × 8 mm) were inserted into 20, 30, and 40 pounds per cubic foot (PCF) density polyurethane blocks. The insertion torque (IT), removal torque (RT), and resonance frequency analysis (RFA) values were recorded for each experimental condition. RESULTS In 30 and 40 PCF blocks, 3p S implants exhibited significantly higher IT values (90 and 80 Ncm, respectively) than 3p L (85 and 50 Ncm, respectively). Similarly, RT was significantly higher for 3p S implants in 30 and 40 PCF blocks (57 and 90 Ncm, respectively). However, there were no significant differences in RFA values, except for the 20 PCF block, where 3pS implants showed significantly lower values (63 ISQ) than 3p L implants (67 ISQ) in both the distal and mesial directions. CONCLUSIONS These results demonstrated that the implant's length mainly influences the IT and RT values in the polyurethane blocks that mimic the mandibular region of the bone, resulting in higher values for the 3p S implants, while the RFA values remained unaffected. However, in the lowest density block simulating the maxillary bone, 3p L implants exhibited significantly higher ISQ values. CLINICAL RELEVANCE Therefore, our data offer valuable insights into the biomechanical behavior of these implants, which could be clinically beneficial for enhancing surgical planning.
Collapse
Affiliation(s)
- Tea Romasco
- Center for Advanced Studies and Technology-CAST, "G. D'Annunzio, University of Chieti-Pescara, Via Luigi Polacchi 11, 66100, Chieti, Italy
- Department of Medical, Oral and Biotechnological Sciences, "G. D'Annunzio" University of Chieti-Pescara, Via dei Vestini 31, 66100, Chieti, Italy
| | - Pamela Pignatelli
- Department of Medical, Oral and Biotechnological Sciences, "G. D'Annunzio" University of Chieti-Pescara, Via dei Vestini 31, 66100, Chieti, Italy
| | - Margherita Tumedei
- Department of Medical, Surgical, and Dental Sciences, University of Milan, Via della Commenda 10, 20122, Milan, Italy
| | - Hamid Heydari Sheikh Hossein
- Center for Advanced Studies and Technology-CAST, "G. D'Annunzio, University of Chieti-Pescara, Via Luigi Polacchi 11, 66100, Chieti, Italy
- Department of Medical, Oral and Biotechnological Sciences, "G. D'Annunzio" University of Chieti-Pescara, Via dei Vestini 31, 66100, Chieti, Italy
- Villa Serena Foundation for Research, Via Leonardo Petruzzi 42, 65013, Città Sant'Angelo, Italy
| | | | - Adriano Piattelli
- School of Dentistry, Saint Camillus International, University of Health and Medical Sciences, Via di Sant'Alessandro 8, 00131, Rome, Italy
- Facultad de Medicina, UCAM Universidad Católica San Antonio de Murcia, Av. de los Jerónimos 135, 30107, Guadalupe de Maciascoque, Spain
| | - Francesco Inchingolo
- Interdisciplinary Department of Medicine, University of Bari "Aldo Moro", Piazza Umberto I, 70121, Bari, Italy
| | - Natalia Di Pietro
- Center for Advanced Studies and Technology-CAST, "G. D'Annunzio, University of Chieti-Pescara, Via Luigi Polacchi 11, 66100, Chieti, Italy.
- Department of Medical, Oral and Biotechnological Sciences, "G. D'Annunzio" University of Chieti-Pescara, Via dei Vestini 31, 66100, Chieti, Italy.
| |
Collapse
|
6
|
Inchingolo F, Inchingolo AM, Avantario P, Settanni V, Fatone MC, Piras F, Di Venere D, Inchingolo AD, Palermo A, Dipalma G. The Effects of Periodontal Treatment on Rheumatoid Arthritis and of Anti-Rheumatic Drugs on Periodontitis: A Systematic Review. Int J Mol Sci 2023; 24:17228. [PMID: 38139057 PMCID: PMC10743440 DOI: 10.3390/ijms242417228] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2023] [Revised: 12/03/2023] [Accepted: 12/05/2023] [Indexed: 12/24/2023] Open
Abstract
Rheumatoid arthritis (RA) and periodontitis are chronic inflammatory diseases that widely spread and share the same patterns of pro-inflammatory cytokines. This systematic review aims to evaluate the effects of non-surgical periodontal treatment (NSPT) on RA and, conversely, the impact of disease-modifying anti-rheumatic drugs (DMARDs) on periodontitis. PubMed, Embase, and Web of Science were searched using the MESH terms "periodontitis" and "rheumatoid arthritis" from January 2012 to September 2023. A total of 49 articles was included in the final analysis, 10 of which were randomized controlled trials. A total of 31 records concerns the effect of NSPT on parameters of RA disease activity, including a 28-joint disease activity score, anti-citrullinated protein antibodies, rheumatoid factor, C reactive protein, erythrocyte sedimentation rate, pro-inflammatory cytokines and acute phase proteins in serum, saliva, gingival crevicular fluid, and synovial fluid. A total of 18 articles investigated the effect of DMARDs on periodontal indexes and on specific cytokine levels. A quality assessment and risk-of-bias of the studies were also performed. Despite some conflicting results, there is evidence that RA patients and periodontitis patients benefit from NSPT and DMARDs, respectively. The limitations of the studies examined are the small samples and the short follow-up (usually 6 months). Further research is mandatory to evaluate if screening and treatment of periodontitis should be performed systematically in RA patients, and if the administration of DMARDs is useful in reducing the production of cytokines in the periodontium.
Collapse
Affiliation(s)
- Francesco Inchingolo
- Department of Interdisciplinary Medicine, University of Bari “Aldo Moro”, 70124 Bari, Italy; (A.M.I.); (P.A.); (V.S.); (F.P.); (D.D.V.); (A.D.I.); (G.D.)
| | - Angelo Michele Inchingolo
- Department of Interdisciplinary Medicine, University of Bari “Aldo Moro”, 70124 Bari, Italy; (A.M.I.); (P.A.); (V.S.); (F.P.); (D.D.V.); (A.D.I.); (G.D.)
| | - Pasquale Avantario
- Department of Interdisciplinary Medicine, University of Bari “Aldo Moro”, 70124 Bari, Italy; (A.M.I.); (P.A.); (V.S.); (F.P.); (D.D.V.); (A.D.I.); (G.D.)
| | - Vito Settanni
- Department of Interdisciplinary Medicine, University of Bari “Aldo Moro”, 70124 Bari, Italy; (A.M.I.); (P.A.); (V.S.); (F.P.); (D.D.V.); (A.D.I.); (G.D.)
| | | | - Fabio Piras
- Department of Interdisciplinary Medicine, University of Bari “Aldo Moro”, 70124 Bari, Italy; (A.M.I.); (P.A.); (V.S.); (F.P.); (D.D.V.); (A.D.I.); (G.D.)
| | - Daniela Di Venere
- Department of Interdisciplinary Medicine, University of Bari “Aldo Moro”, 70124 Bari, Italy; (A.M.I.); (P.A.); (V.S.); (F.P.); (D.D.V.); (A.D.I.); (G.D.)
| | - Alessio Danilo Inchingolo
- Department of Interdisciplinary Medicine, University of Bari “Aldo Moro”, 70124 Bari, Italy; (A.M.I.); (P.A.); (V.S.); (F.P.); (D.D.V.); (A.D.I.); (G.D.)
| | - Andrea Palermo
- College of Medicine and Dentistry, Birmingham B4 6BN, UK;
| | - Gianna Dipalma
- Department of Interdisciplinary Medicine, University of Bari “Aldo Moro”, 70124 Bari, Italy; (A.M.I.); (P.A.); (V.S.); (F.P.); (D.D.V.); (A.D.I.); (G.D.)
| |
Collapse
|
7
|
Inchingolo AM, Inchingolo AD, Carpentiere V, Del Vecchio G, Ferrante L, Di Noia A, Palermo A, Di Venere D, Dipalma G, Inchingolo F. Predictability of Dental Distalization with Clear Aligners: A Systematic Review. Bioengineering (Basel) 2023; 10:1390. [PMID: 38135981 PMCID: PMC10740623 DOI: 10.3390/bioengineering10121390] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2023] [Revised: 11/02/2023] [Accepted: 11/23/2023] [Indexed: 12/24/2023] Open
Abstract
The current review aims to evaluate the scientific evidence relating to the effectiveness of treatment with clear aligners (CAs) in controlling distalization orthodontic tooth movement. "Orthodontics, aligners" and "distalization" were the search terms used on the Scopus, Web of Science and Pubmed databases with the Boolean operator "AND". The results of the last ten years of research were 146 studies; of these, 19 publications were included for this review. The distalization movement is possible with invisible masks alone, but the risk of losing anchorage in the anterior sectors is very probable. The stability of the results and the reduction of unwanted effects can be guaranteed by the use of skeletal anchoring devices and interproximal enamel reduction (IPR), with which compensations are obtained to reduce the initial overjet. Temporary anchorage devices (TADs) can be used to manage posterior anchorage after distalization of maxillary molars with aligners. This hybrid approach has demonstrated the greatest orthodontic success. TADs are useful aids to provide direct and indirect skeletal anchorage. The opposite effect must be considered when planning dental distalization, especially of the molars, in patients with large overjet, and corrective measures or the use of auxiliaries may be necessary to prevent midcourse corrections. This systematic review provides a critical evidence-based assessment of the predictability of dental distalization with CAs, an ever-evolving orthodontic technique.
Collapse
Affiliation(s)
- Angelo Michele Inchingolo
- Department of Interdisciplinary Medicine, University of Bari Aldo Moro, 70124 Bari, Italy; (A.M.I.); (A.D.I.); (V.C.); (G.D.V.); (L.F.); (A.D.N.); (D.D.V.); (F.I.)
| | - Alessio Danilo Inchingolo
- Department of Interdisciplinary Medicine, University of Bari Aldo Moro, 70124 Bari, Italy; (A.M.I.); (A.D.I.); (V.C.); (G.D.V.); (L.F.); (A.D.N.); (D.D.V.); (F.I.)
| | - Vincenzo Carpentiere
- Department of Interdisciplinary Medicine, University of Bari Aldo Moro, 70124 Bari, Italy; (A.M.I.); (A.D.I.); (V.C.); (G.D.V.); (L.F.); (A.D.N.); (D.D.V.); (F.I.)
| | - Gaetano Del Vecchio
- Department of Interdisciplinary Medicine, University of Bari Aldo Moro, 70124 Bari, Italy; (A.M.I.); (A.D.I.); (V.C.); (G.D.V.); (L.F.); (A.D.N.); (D.D.V.); (F.I.)
| | - Laura Ferrante
- Department of Interdisciplinary Medicine, University of Bari Aldo Moro, 70124 Bari, Italy; (A.M.I.); (A.D.I.); (V.C.); (G.D.V.); (L.F.); (A.D.N.); (D.D.V.); (F.I.)
| | - Angela Di Noia
- Department of Interdisciplinary Medicine, University of Bari Aldo Moro, 70124 Bari, Italy; (A.M.I.); (A.D.I.); (V.C.); (G.D.V.); (L.F.); (A.D.N.); (D.D.V.); (F.I.)
| | - Andrea Palermo
- College of Medicine and Dentistry, Birmingham B4 6BN, UK;
| | - Daniela Di Venere
- Department of Interdisciplinary Medicine, University of Bari Aldo Moro, 70124 Bari, Italy; (A.M.I.); (A.D.I.); (V.C.); (G.D.V.); (L.F.); (A.D.N.); (D.D.V.); (F.I.)
| | - Gianna Dipalma
- Department of Interdisciplinary Medicine, University of Bari Aldo Moro, 70124 Bari, Italy; (A.M.I.); (A.D.I.); (V.C.); (G.D.V.); (L.F.); (A.D.N.); (D.D.V.); (F.I.)
| | - Francesco Inchingolo
- Department of Interdisciplinary Medicine, University of Bari Aldo Moro, 70124 Bari, Italy; (A.M.I.); (A.D.I.); (V.C.); (G.D.V.); (L.F.); (A.D.N.); (D.D.V.); (F.I.)
| |
Collapse
|
8
|
Inchingolo AM, Inchingolo AD, Viapiano F, Ciocia AM, Ferrara I, Netti A, Dipalma G, Palermo A, Inchingolo F. Treatment Approaches to Molar Incisor Hypomineralization: A Systematic Review. J Clin Med 2023; 12:7194. [PMID: 38002806 PMCID: PMC10671994 DOI: 10.3390/jcm12227194] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2023] [Revised: 11/15/2023] [Accepted: 11/17/2023] [Indexed: 11/26/2023] Open
Abstract
AIM This systematic review aimed to comprehensively evaluate the available literature on treating molar incisor hypomineralization (MIH) or enamel hypomineralization published between 2013 and 2023, focusing on identifying relevant studies and their characteristics. MATERIALS AND METHODS The search process encompassed reputable academic databases, including PubMed, Scopus, Cochrane Library, and Web of Science, using a precise keyword strategy ("((molar incisor hypomineralization) OR (enamel hypomineralization)) AND (treatment)"). A total of 637 articles were initially retrieved, followed by a strict selection process adhering to PRISMA guidelines. The inclusion criteria encompassed Randomized Control Trials (RCTs), case series with more than five clinical cases (CSs), studies involving human participants, availability as free full-text or accessible with university credentials, and English-language publications. Exclusion criteria included systematic or literature reviews, editorials, single-case reports, studies conducted in vitro, those involving animals, paid articles, and non-English-language publications. RESULTS The search yielded 864 articles, of which 23 met the stringent inclusion criteria after a meticulous selection process. These studies will serve as the basis for a comprehensive analysis of MIH treatment approaches. The systematic review ensures the quality and relevance of the chosen studies for a detailed assessment of MIH treatment strategies. CONCLUSIONS This systematic review will provide valuable insights into the characteristics of selected studies, patient profiles, and available treatment options for molar incisor hypomineralization, contributing to a better understanding of this dental condition's management.
Collapse
Affiliation(s)
- Angelo Michele Inchingolo
- Department of Interdisciplinary Medicine, School of Medicine, University of Bari “Aldo Moro”, 70124 Bari, Italy; (A.M.I.); (A.D.I.); (F.V.); (A.M.C.); (I.F.); (A.N.)
| | - Alessio Danilo Inchingolo
- Department of Interdisciplinary Medicine, School of Medicine, University of Bari “Aldo Moro”, 70124 Bari, Italy; (A.M.I.); (A.D.I.); (F.V.); (A.M.C.); (I.F.); (A.N.)
| | - Fabio Viapiano
- Department of Interdisciplinary Medicine, School of Medicine, University of Bari “Aldo Moro”, 70124 Bari, Italy; (A.M.I.); (A.D.I.); (F.V.); (A.M.C.); (I.F.); (A.N.)
| | - Anna Maria Ciocia
- Department of Interdisciplinary Medicine, School of Medicine, University of Bari “Aldo Moro”, 70124 Bari, Italy; (A.M.I.); (A.D.I.); (F.V.); (A.M.C.); (I.F.); (A.N.)
| | - Irene Ferrara
- Department of Interdisciplinary Medicine, School of Medicine, University of Bari “Aldo Moro”, 70124 Bari, Italy; (A.M.I.); (A.D.I.); (F.V.); (A.M.C.); (I.F.); (A.N.)
| | - Anna Netti
- Department of Interdisciplinary Medicine, School of Medicine, University of Bari “Aldo Moro”, 70124 Bari, Italy; (A.M.I.); (A.D.I.); (F.V.); (A.M.C.); (I.F.); (A.N.)
| | - Gianna Dipalma
- Department of Interdisciplinary Medicine, School of Medicine, University of Bari “Aldo Moro”, 70124 Bari, Italy; (A.M.I.); (A.D.I.); (F.V.); (A.M.C.); (I.F.); (A.N.)
| | - Andrea Palermo
- College of Medicine and Dentistry, Birmingham B4 6BN, UK;
| | - Francesco Inchingolo
- Department of Interdisciplinary Medicine, School of Medicine, University of Bari “Aldo Moro”, 70124 Bari, Italy; (A.M.I.); (A.D.I.); (F.V.); (A.M.C.); (I.F.); (A.N.)
| |
Collapse
|
9
|
Patil S, Licari FW, Bhandi S, Awan KH, Badnjević A, Belli V, Cervino G, Minervini G. The Cytotoxic Effect of Thermoplastic Denture Base Resins: A Systematic Review. J Funct Biomater 2023; 14:411. [PMID: 37623656 PMCID: PMC10455636 DOI: 10.3390/jfb14080411] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2023] [Revised: 07/06/2023] [Accepted: 07/14/2023] [Indexed: 08/26/2023] Open
Abstract
Partial or complete dentures are constructed from thermoplastic resins that are thermally processed and molded. This review examines the presently available evidence for the cytotoxicity of thermoplasticized denture base resins on human gingival epithelial cells, adipose cells, and fibroblasts; human amnion fibroblasts; and mouse fibroblasts. Electronic searches were performed on PubMed, Scopus, Web of Science, and Google Scholar databases to identify relevant articles to be included in the review until September 2022. Clinical, in vivo, and in vitro studies in English language were searched for. The quality of the studies was assessed using the Toxicological data Reliability Assessment tool (ToxRTool) developed by the European Commission's Joint Research Centre. GRADE assessment was used to evaluate the certainty of evidence. Seven in vitro studies were included in the review. The overall risk of bias was determined to be high, with the majority of studies assessed found to be reliable with restrictions or not reliable. Only two studies were considered reliable without restrictions based on ToxRTool assessment. The effect of thermoplastic denture base resins on viability and cell adherence of human gingival or amnion fibroblasts and mouse fibroblasts (L929s) is not significant. Conditioned media from unpolished specimens of resins were significantly more toxic to cultured cells than those from polished specimens. This may be of concern in cases of poor post-processing of dentures. Based on the limited evidence available, there is low-certainty evidence that thermoplastic denture base resins appear to be biocompatible and show insignificant cytotoxicity. Further well-designed trials adhering to standard reporting guidelines and using objective measures are necessary before outlining universal guidelines for best practice. Long-term in vivo and clinical assessment is necessary to corroborate laboratory findings with clinical outcomes. Denture base resins are in constant contact with oral tissues, and cytotoxic components released by the resins may irritate or inflame the tissues or provoke an allergic response.
Collapse
Affiliation(s)
- Shankargouda Patil
- College of Dental Medicine, Roseman University of Health Sciences, South Jordan, UT 84095, USA (S.B.)
| | - Frank W. Licari
- College of Dental Medicine, Roseman University of Health Sciences, South Jordan, UT 84095, USA (S.B.)
| | - Shilpa Bhandi
- College of Dental Medicine, Roseman University of Health Sciences, South Jordan, UT 84095, USA (S.B.)
| | - Kamran H. Awan
- College of Dental Medicine, Roseman University of Health Sciences, South Jordan, UT 84095, USA (S.B.)
| | - Almir Badnjević
- Verlab Research Institute for Biomedical Engineering, Medical Devices and Artificial Intelligence, 71000 Sarajevo, Bosnia and Herzegovina;
| | - Valentina Belli
- Department of Precision Medicine, Università degli Studi della Campania “Luigi Vanvitelli”, 80131 Naples, Italy
| | - Gabriele Cervino
- Department of Biomedical and Dental Sciences, Morphological and Functional Images, University of Messina, G. Martino Polyclinic, 98100 Messina, Italy
| | - Giuseppe Minervini
- Multidisciplinary Department of Medical-Surgical and Dental Specialties, University of Campania, Luigi Vanvitelli, 80138 Naples, Italy;
| |
Collapse
|
10
|
Witek L, Parente PEL, Torroni A, Greenberg M, Nayak VV, Hacquebord JH, Coelho PG. Evaluation of instrumentation and pedicle screw design for posterior lumbar fixation: A pre-clinical in vivo/ex vivo ovine model. JOR Spine 2023; 6:e1245. [PMID: 37361331 PMCID: PMC10285755 DOI: 10.1002/jsp2.1245] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/22/2021] [Revised: 10/10/2022] [Accepted: 12/21/2022] [Indexed: 01/15/2023] Open
Abstract
Background Stabilization procedures of the lumbar spine are routinely performed for various conditions, such as spondylolisthesis and scoliosis. Spine surgery has become even more common, with the incidence rates increasing ~30% between 2004 and 2015. Various solutions to increase the success of lumbar stabilization procedures have been proposed, ranging from the device's geometrical configuration to bone quality enhancement via grafting and, recently, through modified drilling instrumentation. Conventional (manual) instrumentation renders the excavated bony fragments ineffective, whereas the "additive" osseodensification rotary drilling compacts the bone fragments into the osteotomy walls, creating nucleating sites for regeneration. Methods This study aimed to compare both manual versus rotary Osseodensification (OD) instrumentation as well as two different pedicle screw thread designs in a controlled split animal model in posterior lumbar stabilization to determine the feasibility and potential advantages of each variable with respect to mechanical stability and histomorphology. A total of 164 single thread (82 per thread configuration), pedicle screws (4.5 × 35 mm) were used for the study. Each animal received eight pedicles (four per thread design) screws, which were placed in the lumbar spine of 21 adult sheep. One side of the lumbar spine underwent rotary osseodensification instrumentation, while the contralateral underwent conventional, hand, instrumentation. The animals were euthanized after 6- and 24-weeks of healing, and the vertebrae were removed for biomechanical and histomorphometric analyses. Pullout strength and histologic analysis were performed on all harvested samples. Results The rotary instrumentation yielded statistically (p = 0.026) greater pullout strength (1060.6 N ± 181) relative to hand instrumentation (769.3 N ± 181) at the 24-week healing time point. Histomorphometric analysis exhibited significantly higher degrees of bone to implant contact for the rotary instrumentation only at the early healing time point (6 weeks), whereas bone area fraction occupancy was statistically higher for rotary instrumentation at both healing times. The levels of soft tissue infiltration were lower for pedicle screws placed in osteotomies prepared using OD instrumentation relative to hand instrumentation, independent of healing time. Conclusion The rotary instrumentation yielded enhanced mechanical and histologic results relative to the conventional hand instrumentation in this lumbar spine stabilization model.
Collapse
Affiliation(s)
- Lukasz Witek
- Biomaterials DivisionNew York University College of DentistryNew YorkNew YorkUSA
- Department of Biomedical EngineeringNew York University Tandon School of EngineeringBrooklynNew YorkUSA
| | | | - Andrea Torroni
- Hansjörg Wyss Department of Plastic SurgeryNew York University School of MedicineNew YorkNew YorkUSA
| | - Michael Greenberg
- Biomaterials DivisionNew York University College of DentistryNew YorkNew YorkUSA
| | - Vasudev Vivekanand Nayak
- Biomaterials DivisionNew York University College of DentistryNew YorkNew YorkUSA
- Department of Mechanical and Aerospace EngineeringNew York University Tandon School of EngineeringBrooklynNew YorkUSA
| | - Jacques Henri Hacquebord
- Hansjörg Wyss Department of Plastic SurgeryNew York University School of MedicineNew YorkNew YorkUSA
- Department of Orthopedic SurgeryNew York University School of MedicineNew YorkNew YorkUSA
| | - Paulo G. Coelho
- Division of Plastic Surgery, Department of SurgeryUniversity of Miami Miller School of MedicineMiamiFloridaUSA
- Department of Biochemistry and Molecular BiologyUniversity of Miami Miller School of MedicineMiamiFloridaUSA
| |
Collapse
|
11
|
Olmedo-Gaya MV, Romero-Olid MN, Ocaña-Peinado FM, Vallecillo-Rivas M, Vallecillo C, Reyes-Botella C. Influence of different surgical techniques on primary implant stability in the posterior maxilla: a randomized controlled clinical trial. Clin Oral Investig 2023:10.1007/s00784-023-04962-y. [PMID: 36977760 DOI: 10.1007/s00784-023-04962-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2022] [Accepted: 03/19/2023] [Indexed: 03/30/2023]
Abstract
BACKGROUND AND OBJECTIVE Primary stability (PS) is remarkable for secondary stability and implant success. Surgical technique modifications seem to improve primary stability, especially in poor quality bone. The aim of this study was to compare the insertion torque (IT) and implant stability quotients (ISQ) of implants placed with underpreparation, expanders, and standard surgical instrumentation in different bone types. MATERIAL AND METHODS This randomized controlled clinical trial enrolled 108 patients (n=108 implants) distributed in three study groups: group 1 (n=36) underpreparation technique, group 2 (n=36) expander technique, and group 3 (n=36) conventional drilling. IT was recorded with a torque indicator. ISQ was recorded with resonance frequency analysis immediately after surgery. RESULTS ISQ values were associated with the patient's bone quality and were higher in bone quality type II (76.65) and type III (73.60) and lower in bone quality type IV (67.34), with statistically significant differences (p<0.0001). Lower stability results were obtained when conventional drilling (69.31) was used compared to the use of underpreparation (74.29) or expanders (73.99) with a level of significance of p=0.008 and p=0.005, respectively. CONCLUSIONS The surgical technique influences the PS when there is low-quality bone. In low-quality bones, conventional drilling obtains lower ISQ values. CLINICAL RELEVANCE Replace the conventional drilling technique for an alternative, underpreparation or expanders, in low-quality bone in order to achieve greater primary stability.
Collapse
Affiliation(s)
| | | | | | | | - Cristina Vallecillo
- Department of Stomatology, School of Dentistry, University of Granada, Granada, Spain.
- Faculty of Dentistry, University of Granada, Colegio Máximo de Cartuja s/n, 18071, Granada, Spain.
| | - Candela Reyes-Botella
- Department of Stomatology, School of Dentistry, University of Granada, Granada, Spain
| |
Collapse
|
12
|
de Carvalho Formiga M, Grzech-Leśniak K, Moraschini V, Shibli JA, Neiva R. Effects of Osseodensification on Immediate Implant Placement: Retrospective Analysis of 211 Implants. MATERIALS 2022; 15:ma15103539. [PMID: 35629566 PMCID: PMC9147081 DOI: 10.3390/ma15103539] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/18/2022] [Revised: 05/07/2022] [Accepted: 05/12/2022] [Indexed: 01/14/2023]
Abstract
Osseodensification is a new method of bone instrumentation for dental implant placement that preserves bulk bone and increases primary implant stability, and may accelerate the implant rehabilitation treatment period and provide higher success and survival rates than conventional methods. The aim of this retrospective study was to evaluate and discuss results obtained on immediate implant placement with immediate and delayed loading protocols under Osseodensification bone instrumentation. This study included private practice patients that required dental implant rehabilitation, between February 2017 and October 2019. All implants were placed under Osseodensification and had to be in function for at least 12 months to be included on the study. A total of 211 implants were included in the study, with a 98.1% total survival rate (97.9% in the maxilla and 98.5% in the mandible). For immediate implants with immediate load, 99.2% survival rate was achieved, and 100% survival rate for immediate implant placement without immediate load cases. A total of four implants were lost during this period, and all of them were lost within two months after placement. Within the limitations of this study, it can be concluded that Osseodensification bone instrumentation provided similar or better results on survival rates than conventional bone instrumentation.
Collapse
Affiliation(s)
| | - Kinga Grzech-Leśniak
- Laser Laboratory Oral Surgery Department, Medical University of Wroclaw, 50-425 Wroclaw, Poland;
| | - Vittorio Moraschini
- Department of Periodontology, Veiga de Almeida University, Rio de Janeiro 20271-020, Brazil;
| | - Jamil Awad Shibli
- Department of Periodontology and Oral Implantology, Dental Research Division, University of Guarulhos, Guarulhos 07023-040, Brazil
- Correspondence:
| | - Rodrigo Neiva
- Department of Periodontics, School of Dental Medicine, University of Pennsylvania, Philadelphia, PA 19104, USA;
| |
Collapse
|
13
|
Fixture Length and Primary Stability: An In Vitro Study on Polyurethane Foam. APPLIED SCIENCES-BASEL 2022. [DOI: 10.3390/app12052683] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
(1) Background: Recently, novel dental implants that are characterized by different levels of surface roughness in the distinct parts of the fixture’s body have been introduced in the market. These surface characteristics could affect the primary stability of the implants. The aim of this in vitro study was to compare the primary stability of short and long implants, characterized by multiscale surface roughness, inserted on polyurethane blocks. The secondary aim was to understand if the implant length could be a crucial factor in the decision-making in immediate or rather than delayed loading protocol in the different bone densities. (2) Methods: A total of 20 cylindrical dental implants with a diameter of 5.0 mm were tested for the lengths 6.0 mm (short implants) versus 13.0 mm (long implants) on two different solid rigid polyurethane blocks (20 and 30 PCF). The primary stability was evaluated by measuring the insertion torque value (ITV), the removal torque (RTV), and the resonance frequency analysis RFA. (3) Results: The values of ITV, RTV, and RFA showed the same trend in all measurements. Long implants showed a significantly higher primary stability on 30 PCF blocks that present mechanical properties similar to high-density bone. On the contrary, no relevant differences were found on 20 PCF blocks, which mimic trabecular bone density. (4) Conclusions: The impact of fixture length on the primary stability of implants with multiscale surface roughness is significant in 30 PCF polyurethane corresponding to higher bone density, but not in lower ones.
Collapse
|
14
|
Inchingolo F, Hazballa D, Inchingolo AD, Malcangi G, Marinelli G, Mancini A, Maggiore ME, Bordea IR, Scarano A, Farronato M, Tartaglia GM, Lorusso F, Inchingolo AM, Dipalma G. Innovative Concepts and Recent Breakthrough for Engineered Graft and Constructs for Bone Regeneration: A Literature Systematic Review. MATERIALS (BASEL, SWITZERLAND) 2022; 15:1120. [PMID: 35161065 PMCID: PMC8839672 DOI: 10.3390/ma15031120] [Citation(s) in RCA: 30] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/14/2021] [Revised: 01/26/2022] [Accepted: 01/27/2022] [Indexed: 02/06/2023]
Abstract
BACKGROUND For decades, regenerative medicine and dentistry have been improved with new therapies and innovative clinical protocols. The aim of the present investigation was to evaluate through a critical review the recent innovations in the field of bone regeneration with a focus on the healing potentials and clinical protocols of bone substitutes combined with engineered constructs, growth factors and photobiomodulation applications. METHODS A Boolean systematic search was conducted by PubMed/Medline, PubMed/Central, Web of Science and Google scholar databases according to the PRISMA guidelines. RESULTS After the initial screening, a total of 304 papers were considered eligible for the qualitative synthesis. The articles included were categorized according to the main topics: alloplastic bone substitutes, autologous teeth derived substitutes, xenografts, platelet-derived concentrates, laser therapy, microbiota and bone metabolism and mesenchymal cells construct. CONCLUSIONS The effectiveness of the present investigation showed that the use of biocompatible and bio-resorbable bone substitutes are related to the high-predictability of the bone regeneration protocols, while the oral microbiota and systemic health of the patient produce a clinical advantage for the long-term success of the regeneration procedures and implant-supported restorations. The use of growth factors is able to reduce the co-morbidity of the regenerative procedure ameliorating the post-operative healing phase. The LLLT is an adjuvant protocol to improve the soft and hard tissues response for bone regeneration treatment protocols.
Collapse
Affiliation(s)
- Francesco Inchingolo
- Department of Interdisciplinary Medicine, University of Medicine Aldo Moro, 70124 Bari, Italy; (D.H.); (A.D.I.); (G.M.); (G.M.); (A.M.); (M.E.M.); (A.M.I.)
| | - Denisa Hazballa
- Department of Interdisciplinary Medicine, University of Medicine Aldo Moro, 70124 Bari, Italy; (D.H.); (A.D.I.); (G.M.); (G.M.); (A.M.); (M.E.M.); (A.M.I.)
- Kongresi Elbasanit, Rruga: Aqif Pasha, 3001 Elbasan, Albania
| | - Alessio Danilo Inchingolo
- Department of Interdisciplinary Medicine, University of Medicine Aldo Moro, 70124 Bari, Italy; (D.H.); (A.D.I.); (G.M.); (G.M.); (A.M.); (M.E.M.); (A.M.I.)
| | - Giuseppina Malcangi
- Department of Interdisciplinary Medicine, University of Medicine Aldo Moro, 70124 Bari, Italy; (D.H.); (A.D.I.); (G.M.); (G.M.); (A.M.); (M.E.M.); (A.M.I.)
| | - Grazia Marinelli
- Department of Interdisciplinary Medicine, University of Medicine Aldo Moro, 70124 Bari, Italy; (D.H.); (A.D.I.); (G.M.); (G.M.); (A.M.); (M.E.M.); (A.M.I.)
| | - Antonio Mancini
- Department of Interdisciplinary Medicine, University of Medicine Aldo Moro, 70124 Bari, Italy; (D.H.); (A.D.I.); (G.M.); (G.M.); (A.M.); (M.E.M.); (A.M.I.)
| | - Maria Elena Maggiore
- Department of Interdisciplinary Medicine, University of Medicine Aldo Moro, 70124 Bari, Italy; (D.H.); (A.D.I.); (G.M.); (G.M.); (A.M.); (M.E.M.); (A.M.I.)
| | - Ioana Roxana Bordea
- Department of Oral Rehabilitation, Faculty of Dentistry, Iuliu Hațieganu University of Medicine and Pharmacy, 400012 Cluj-Napoca, Romania;
| | - Antonio Scarano
- Department of Innovative Technologies in Medicine and Dentistry, University of Chieti-Pescara, 66100 Chieti, Italy;
| | - Marco Farronato
- UOC Maxillo-Facial Surgery and Dentistry, Department of Biomedical, Surgical and Dental Sciences, School of Dentistry, Fondazione IRCCS Ca Granda, Ospedale Maggiore Policlinico, University of Milan, 20100 Milan, Italy; (M.F.); (G.M.T.)
| | - Gianluca Martino Tartaglia
- UOC Maxillo-Facial Surgery and Dentistry, Department of Biomedical, Surgical and Dental Sciences, School of Dentistry, Fondazione IRCCS Ca Granda, Ospedale Maggiore Policlinico, University of Milan, 20100 Milan, Italy; (M.F.); (G.M.T.)
| | - Felice Lorusso
- Department of Innovative Technologies in Medicine and Dentistry, University of Chieti-Pescara, 66100 Chieti, Italy;
| | - Angelo Michele Inchingolo
- Department of Interdisciplinary Medicine, University of Medicine Aldo Moro, 70124 Bari, Italy; (D.H.); (A.D.I.); (G.M.); (G.M.); (A.M.); (M.E.M.); (A.M.I.)
| | - Gianna Dipalma
- Department of Interdisciplinary Medicine, University of Medicine Aldo Moro, 70124 Bari, Italy; (D.H.); (A.D.I.); (G.M.); (G.M.); (A.M.); (M.E.M.); (A.M.I.)
| |
Collapse
|
15
|
Mechanical Behaviour and Primary Stability of a Self-Condensing Implant: A Laboratory Critical Simulation of a Severe Maxillary Atrophy on Polyurethane Lamina. APPLIED SCIENCES-BASEL 2022. [DOI: 10.3390/app12030966] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/10/2022]
Abstract
Background: Posterior maxillary atrophies could emerge after the loss of teeth, trauma, infections, or lesions that often require regenerative approaches. In these critical conditions, the achievement of implant primary stability represents a clinical challenge in the operative practice. Therefore, a two-stage approach is often preferred with a delay of the rehabilitation time and a consistent increasing of the biological and the operative costs. The aim of this study was to evaluate the mechanical behaviour of a self-condenser implant compared to a standard implant in a critical simulation on different thicknesses and densities of polyurethane lamina. Materials and methods: A total of two implant models were tested: a self-condensing device (test) and a standard implant (control). The study evaluated the insertion torque and the pull-out strength values of the test and control implants inserted in different sizes (1, 2, and 3 mm) and density polyurethane lamina (10, 20, and 30 pcf) for a total of 320 experimental sites. Results: In total, 320 experimental sites were produced in the polyurethane samples. A statistically significant difference of insertion and pull-out torque values between the test and control Implants was found in the different bone densities (p < 0.05). The insertion and pull-out torque values were always higher for the test implants in all experimental conditions. In all bone densities, the insertion torque values were higher than the pull-out torque values. The self-condenser dental implant design evaluated in this in vitro study showed a high level of stability in all experimental conditions. Conclusions: The test implant could represent a useful tool for a one-stage surgical approach in the presence of limited residual native bone as an alternative to a delayed technique.
Collapse
|
16
|
Can the design of the instruments used for undersized osteotomies influence the initial stability of implants installed in low-density bone? An in vitro pilot study. PLoS One 2021; 16:e0257985. [PMID: 34618848 PMCID: PMC8496820 DOI: 10.1371/journal.pone.0257985] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2021] [Accepted: 09/14/2021] [Indexed: 12/11/2022] Open
Abstract
Objectives The aims of this study were to compare the initial implant stability obtained using four different osteotomy techniques in low-density synthetic bone, to evaluate the instrument design in comparison to the implant design, and to determinate a possible correlation between the insertion torque and initial stability quotient (ISQ). Materials and methods Four groups were identified in accordance with the osteotomy technique used (n = 10 implants per group): group G1, osteotomy using the recommended drilling sequence; group G2, osteotomy using an undersized compactor drill; group G3, osteotomy using an undersized drill; and group G4, osteotomy using universal osseodensification drills. Two polyurethane blocks were used: block 1, with a medullary portion of 10 pounds per cubic foot (PCF 10) and with a 1 mm cortical portion of PCF 40, and block 2, with a medullary of PCF 15 and with a 2 mm cortical portion of PCF 40. Tapered implants of 4 mm in diameter and 11 mm in length were used. The insertion torque (IT) and ISQ were measured. The dimensions of the final instrument used in each group and the dimensions of the implant were used to calculate the total area of each part, and these data were compared. Results Differences between the four groups were found for IT and ISQ values depending on the technique used for the osteotomy in the two synthetic bone models (p < 0.0001). All groups showed lower values of initial stability in block 1 than in block 2. Conclusions Undersized osteotomies with instruments designed according to the implant body significantly increased the initial stability values compared to beds prepared with universal drills and using the drilling sequence standardized by the manufacturer.
Collapse
|
17
|
An In Vitro Analysis on Polyurethane Foam Blocks of the Insertion Torque (IT) Values, Removal Torque Values (RTVs), and Resonance Frequency Analysis (RFA) Values in Tapered and Cylindrical Implants. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2021; 18:ijerph18179238. [PMID: 34501824 PMCID: PMC8431239 DOI: 10.3390/ijerph18179238] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/03/2021] [Revised: 08/28/2021] [Accepted: 08/30/2021] [Indexed: 12/24/2022]
Abstract
Background: Several different dental implant microgeometries have been investigated in the literature for use in low-density bone sites. The polyurethane solid rigid blocks represent an optimal in vitro study model for dental implants, because their composition is characterized by symmetrical linear chains of monomers of hexa-methylene sequences producing a self-polymerization process. The aim of the present investigation was to evaluate the primary stability of cylindrical and tapered implants positioned into low-density polyurethane solid rigid blocks. Materials and Methods: Two different macrogeometries, cylindrical (4 mm diameter and 10 mm length) and tapered dental implants (4.20 mm diameter and 10 mm length), were investigated in the present study. The implants were inserted into 10 PCF and 20 PCF polyurethane blocks, with and without an additional cortical layer. The insertion torque (IT) values, the removal torque values (RTVs), and the resonance frequency analysis (RFA) values were measured and recorded. Results: A total of 80 sites were tested, and a significant increased primary stability (PS) was detected in favour of tapered dental implants when compared to cylindrical implants in all experimental conditions (p < 0.05). Higher IT, RT, and RFA values were measured in tapered implants in 10 and 20 PCF polyurethane blocks, both with and without the additional cortical layer. Conclusions: Both implants showed sufficient primary stability in poor density substrates, while, on the other hand, the tapered microgeometry showed characteristics that could also lead to clinical application in low-density posterior maxillary sites, even with a drastically decreased bone cortical component.
Collapse
|
18
|
Gehrke SA, Scarano A, de Lima JHC, Bianchini MA, Dedavid BA, De Aza PN. Effects of the Healing Chambers in Implant Macrogeometry Design in a Low-Density Bone Using Conventional and Undersized Drilling. J Int Soc Prev Community Dent 2021; 11:437-447. [PMID: 34430506 PMCID: PMC8352059 DOI: 10.4103/jispcd.jispcd_96_21] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2021] [Revised: 06/14/2021] [Accepted: 05/22/2021] [Indexed: 11/04/2022] Open
Abstract
Background: The ideal installation technique or implant macrogeometry for obtaining an adequate osseointegration in low-density bone tissue follows a challenge in the implantology. Aims and Objective: The aim of the present study was to evaluate the behavior of three osteotomy techniques and two implant macrogeometries in two low-density polyurethane blocks. The insertion torque (IT), initial stability, pullout resistance, and weight of the residual bone material deposited on the implants were assessed. Materials and Methods: A total of 120 implants with two different macrogeometries were used. They were divided into six groups according to the implant macrogeometry and the drilling technique performed (n = 20 implants per group). The implants were installed in polyurethane blocks with pounds per cubic foot (PCF) 10 and PCF 20 densities. The IT, initial stability, pullout resistance, and weight residual bone were measured. Results: Differences were found in the values referring to the macrogeometry of the implants and the type of osteotomy performed. In all groups, the initial stability of the PCF 10 blocks was quite low. The undersized osteotomies significantly increased the values measured in all tests in the PCF 20 density blocks. Conclusions: In conclusion, even when a modified (undersized) osteotomy technique is used, implants inserted in low-quality bone (type IV) can present problems for osseointegration due their low initial stability and bone resistance. However, the modification in the implant macrogeometry (with healing chambers) presented more quantity of bone on the surface after the pullout test.
Collapse
Affiliation(s)
- Sergio A Gehrke
- Department of Research, Biotecnos, Montevideo, Uruguay.,Department of Biotechnology, Universidad Católica de Murcia, Murcia, Spain.,Instituto de Bioingenieria, Universidad Miguel Hernández, Elche (Alicante), Spain
| | - Antônio Scarano
- Department of Medical, Oral and Biotechnological Sciences, University of Chieti-Pescara, Chieti, Italy
| | - José H C de Lima
- Department of Rehabilitation, Universidade Federal Fluminense, Rio de Janeiro, Brazil
| | - Marco A Bianchini
- Post-Graduate Program in Implant Dentistry, Federal University of Santa Catarina, Florianópolis, SC, Brazil
| | - Berenice A Dedavid
- Department of Materials Engineering, Pontificia Catholic University of Rio Grande do Sul, Porto Alegre, Brazil
| | - Piedad N De Aza
- Instituto de Bioingenieria, Universidad Miguel Hernández, Elche (Alicante), Spain
| |
Collapse
|
19
|
Comparison of Implant Stability between Regenerated and Non-Regenerated Bone. A Prospective Cohort Study. J Clin Med 2021; 10:jcm10153220. [PMID: 34362004 PMCID: PMC8347999 DOI: 10.3390/jcm10153220] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2021] [Revised: 07/16/2021] [Accepted: 07/19/2021] [Indexed: 02/07/2023] Open
Abstract
Implant stability is one of the main indicators of successful osseointegration. Although it has been measured in numerous studies, there has been little research on implant stability in regenerated bone. The study compares primary and secondary stability between implants placed in regenerated versus native bone and evaluates the influence of bone quality on the results. Sixty implants were placed in 31 patients: 30 implants inserted in native bone (non-regenerated) after a healing period of at least 6 months post-exodontia and 30 inserted in regenerated bone at 6 months after grafting with xenograft. Resonance frequency analysis (RFA) was used to obtain implant stability quotient (ISQ) values at baseline (implant placement), 8 weeks, and 12 weeks. Statistically significant differences were found between implants placed in regenerated bone and those placed in native bone at all measurement time points (p < 0.05). ISQ values were significantly influenced by bone quality at baseline (p < 0.05) but not at 8 or 12 weeks. Greater stability was obtained in implants placed in native bone; however, those placed in regenerated bone showed adequate primary and secondary stability for prosthetic loading. Bone quality influences the primary but not secondary stability of the implants in both native and regenerated bone.
Collapse
|
20
|
Contaldo M, De Rosa A, Nucci L, Ballini A, Malacrinò D, La Noce M, Inchingolo F, Xhajanka E, Ferati K, Bexheti-Ferati A, Feola A, Di Domenico M. Titanium Functionalized with Polylysine Homopolymers: In Vitro Enhancement of Cells Growth. MATERIALS 2021; 14:ma14133735. [PMID: 34279306 PMCID: PMC8269806 DOI: 10.3390/ma14133735] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/30/2021] [Revised: 06/25/2021] [Accepted: 07/01/2021] [Indexed: 12/12/2022]
Abstract
In oral implantology, the success and persistence of dental implants over time are guaranteed by the bone formation around the implant fixture and by the integrity of the peri-implant mucosa seal, which adheres to the abutment and becomes a barrier that hinders bacterial penetration and colonization close to the outer parts of the implant. Research is constantly engaged in looking for substances to coat the titanium surface that guarantees the formation and persistence of the peri-implant bone, as well as the integrity of the mucous perimeter surrounding the implant crown. The present study aimed to evaluate in vitro the effects of a titanium surface coated with polylysine homopolymers on the cell growth of dental pulp stem cells and keratinocytes to establish the potential clinical application. The results reported an increase in cell growth for both cellular types cultured with polylysine-coated titanium compared to cultures without titanium and those without coating. These preliminary data suggest the usefulness of polylysine coating not only for enhancing osteoinduction but also to speed the post-surgery mucosal healings, guarantee appropriate peri-implant epithelial seals, and protect the fixture against bacterial penetration, which is responsible for compromising the implant survival.
Collapse
Affiliation(s)
- Maria Contaldo
- Multidisciplinary Department of Medical-Surgical and Dental Specialties, University of Campania Luigi Vanvitelli, Via Luigi de Crecchio, 6, 80138 Naples, Italy; (A.D.R.); (L.N.)
- Correspondence: (M.C.); (M.D.D.); Tel.: +39-32-0487-6058 (M.C.)
| | - Alfredo De Rosa
- Multidisciplinary Department of Medical-Surgical and Dental Specialties, University of Campania Luigi Vanvitelli, Via Luigi de Crecchio, 6, 80138 Naples, Italy; (A.D.R.); (L.N.)
| | - Ludovica Nucci
- Multidisciplinary Department of Medical-Surgical and Dental Specialties, University of Campania Luigi Vanvitelli, Via Luigi de Crecchio, 6, 80138 Naples, Italy; (A.D.R.); (L.N.)
| | - Andrea Ballini
- Department of Biosciences, Biotechnologies and Biopharmaceutics, Campus Universitario Ernesto Quagliariello, University of Bari “Aldo Moro”, 70125 Bari, Italy;
- Department of Precision Medicine, University of Campania Luigi Vanvitelli, 80138 Naples, Italy
| | - Davide Malacrinò
- Department of Research, Development and Quality Assessment, AISER SA, Rue du Rhone, 14 VH-1204 Genève, Switzerland;
| | - Marcella La Noce
- Department of Experimental Medicine, Università Degli Studi della Campania Luigi Vanvitelli, Campania, 80138 Naples, Italy;
| | - Francesco Inchingolo
- Department of Interdisciplinary Medicine, University of Medicine Aldo Moro, 70124 Bari, Italy;
| | - Edit Xhajanka
- Department of Dental Prosthesis, Medical University of Tirana, Rruga e Dibrës, U.M.T., 1001 Tirana, Albania;
| | - Kenan Ferati
- Faculty of Medicine, University of Tetovo, 1220 Tetovo, North Macedonia; (K.F.); (A.B.-F.)
| | | | - Antonia Feola
- Department of Biology, University of Naples “Federico II”, 80138 Naples, Italy;
| | - Marina Di Domenico
- Department of Precision Medicine, University of Campania Luigi Vanvitelli, 80138 Naples, Italy
- Department of Biology, College of Science and Technology, Temple University, Philadelphia, PA 19122, USA
- Correspondence: (M.C.); (M.D.D.); Tel.: +39-32-0487-6058 (M.C.)
| |
Collapse
|
21
|
Patano A, Cirulli N, Beretta M, Plantamura P, Inchingolo AD, Inchingolo AM, Bordea IR, Malcangi G, Marinelli G, Scarano A, Lorusso F, Inchingolo F, Dipalma G. Education Technology in Orthodontics and Paediatric Dentistry during the COVID-19 Pandemic: A Systematic Review. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2021; 18:6056. [PMID: 34199882 PMCID: PMC8200064 DOI: 10.3390/ijerph18116056] [Citation(s) in RCA: 25] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/01/2021] [Revised: 05/27/2021] [Accepted: 06/02/2021] [Indexed: 12/14/2022]
Abstract
Over the last decade, medical education changed from traditional teaching methods to telematic and networking scholar and e-learning approach. The objective of the present systematic review was to evaluate the effectiveness and teachers/student's acceptability of e-learning applied to the field of orthodontics and paediatric dentistry. A database search of the literature was conducted on PubMed and Embase databases from January 2005 to May 2021. A total of 172 articles were identified by the electronic search, while a total of 32 papers were selected for qualitative analysis. Overall, 19 articles investigated the effectiveness of e-learning, and no difference of acceptability was reported between e-learning and traditional methods for a wide part of the articles selected. A total of 25 papers provided a satisfaction questionnaire for learners and all were positive in their attitude towards e-learning. The results showed that e-learning is an effective method of instruction, complementing the traditional teaching methods, and learners had a positive attitude and perception. The evidence of the present study reported a high level of acceptability and knowledge level of e-learning techniques, compared to frontal lecture methods, in the fields of orthodontics and paediatric dentistry.
Collapse
Affiliation(s)
- Assunta Patano
- Department of Interdisciplinary Medicine, University of Bari “Aldo Moro”, 70124 Bari, Italy; (A.P.); (N.C.); (A.D.I.); (A.M.I.); (G.M.); (F.I.); (G.D.)
| | - Nunzio Cirulli
- Department of Interdisciplinary Medicine, University of Bari “Aldo Moro”, 70124 Bari, Italy; (A.P.); (N.C.); (A.D.I.); (A.M.I.); (G.M.); (F.I.); (G.D.)
- Private Practice in Bari, 70121 Bari, Italy
| | - Matteo Beretta
- Digital Dentistry, Private in Varese, 21100 Varese, Italy;
| | - Paola Plantamura
- Department of Computer Science, University of Bari “Aldo Moro”, 70121 Bari, Italy;
| | - Alessio Danilo Inchingolo
- Department of Interdisciplinary Medicine, University of Bari “Aldo Moro”, 70124 Bari, Italy; (A.P.); (N.C.); (A.D.I.); (A.M.I.); (G.M.); (F.I.); (G.D.)
| | - Angelo Michele Inchingolo
- Department of Interdisciplinary Medicine, University of Bari “Aldo Moro”, 70124 Bari, Italy; (A.P.); (N.C.); (A.D.I.); (A.M.I.); (G.M.); (F.I.); (G.D.)
| | - Ioana Roxana Bordea
- Department of Oral Rehabilitation, Faculty of Dentistry, Iuliu Hațieganu University of Medicine and Pharmacy, 400012 Cluj-Napoca, Romania
| | - Giuseppina Malcangi
- Department of Interdisciplinary Medicine, University of Bari “Aldo Moro”, 70124 Bari, Italy; (A.P.); (N.C.); (A.D.I.); (A.M.I.); (G.M.); (F.I.); (G.D.)
| | - Grazia Marinelli
- Department of Interdisciplinary Medicine, University of Bari “Aldo Moro”, 70124 Bari, Italy; (A.P.); (N.C.); (A.D.I.); (A.M.I.); (G.M.); (F.I.); (G.D.)
| | - Antonio Scarano
- Department of Innovative Technologies in Medicine and Dentistry, University of Chieti-Pescara, 66100 Chieti, Italy;
| | - Felice Lorusso
- Department of Innovative Technologies in Medicine and Dentistry, University of Chieti-Pescara, 66100 Chieti, Italy;
| | - Francesco Inchingolo
- Department of Interdisciplinary Medicine, University of Bari “Aldo Moro”, 70124 Bari, Italy; (A.P.); (N.C.); (A.D.I.); (A.M.I.); (G.M.); (F.I.); (G.D.)
| | - Gianna Dipalma
- Department of Interdisciplinary Medicine, University of Bari “Aldo Moro”, 70124 Bari, Italy; (A.P.); (N.C.); (A.D.I.); (A.M.I.); (G.M.); (F.I.); (G.D.)
| |
Collapse
|
22
|
Inchingolo AD, Dipalma G, Inchingolo AM, Malcangi G, Santacroce L, D’Oria MT, Isacco CG, Bordea IR, Candrea S, Scarano A, Morandi B, Del Fabbro M, Farronato M, Tartaglia GM, Balzanelli MG, Ballini A, Nucci L, Lorusso F, Taschieri S, Inchingolo F. The 15-Months Clinical Experience of SARS-CoV-2: A Literature Review of Therapies and Adjuvants. Antioxidants (Basel) 2021; 10:881. [PMID: 34072708 PMCID: PMC8226610 DOI: 10.3390/antiox10060881] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2021] [Revised: 05/23/2021] [Accepted: 05/26/2021] [Indexed: 02/06/2023] Open
Abstract
BACKGROUND Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is the virus responsible for the coronavirus disease of 2019 (COVID-19) that emerged in December 2019 in Wuhan, China, and rapidly spread worldwide, with a daily increase in confirmed cases and infection-related deaths. The World Health Organization declared a pandemic on the 11th of March 2020. COVID-19 presents flu-like symptoms that become severe in high-risk medically compromised subjects. The aim of this study was to perform an updated overview of the treatments and adjuvant protocols for COVID-19. METHODS A systematic literature search of databases was performed (MEDLINE PubMed, Google Scholar, UpToDate, Embase, and Web of Science) using the keywords: "COVID-19", "2019-nCoV", "coronavirus" and "SARS-CoV-2" (date range: 1 January 2019 to 31st October 2020), focused on clinical features and treatments. RESULTS The main treatments retrieved were antivirals, antimalarials, convalescent plasma, immunomodulators, corticosteroids, anticoagulants, and mesenchymal stem cells. Most of the described treatments may provide benefits to COVID-19 subjects, but no one protocol has definitively proven its efficacy. CONCLUSIONS While many efforts are being spent worldwide in research aimed at identifying early diagnostic methods and evidence-based effective treatments, mass vaccination is thought to be the best option against this disease in the near future.
Collapse
Affiliation(s)
- Alessio Danilo Inchingolo
- Department of Interdisciplinary Medicine, University of Medicine Aldo Moro, 70124 Bari, Italy; (A.D.I.); (G.D.); (A.M.I.); (L.S.); (M.T.D.); (C.G.I.); (F.I.)
| | - Gianna Dipalma
- Department of Interdisciplinary Medicine, University of Medicine Aldo Moro, 70124 Bari, Italy; (A.D.I.); (G.D.); (A.M.I.); (L.S.); (M.T.D.); (C.G.I.); (F.I.)
| | - Angelo Michele Inchingolo
- Department of Interdisciplinary Medicine, University of Medicine Aldo Moro, 70124 Bari, Italy; (A.D.I.); (G.D.); (A.M.I.); (L.S.); (M.T.D.); (C.G.I.); (F.I.)
| | - Giuseppina Malcangi
- Department of Interdisciplinary Medicine, University of Medicine Aldo Moro, 70124 Bari, Italy; (A.D.I.); (G.D.); (A.M.I.); (L.S.); (M.T.D.); (C.G.I.); (F.I.)
| | - Luigi Santacroce
- Department of Interdisciplinary Medicine, University of Medicine Aldo Moro, 70124 Bari, Italy; (A.D.I.); (G.D.); (A.M.I.); (L.S.); (M.T.D.); (C.G.I.); (F.I.)
| | - Maria Teresa D’Oria
- Department of Interdisciplinary Medicine, University of Medicine Aldo Moro, 70124 Bari, Italy; (A.D.I.); (G.D.); (A.M.I.); (L.S.); (M.T.D.); (C.G.I.); (F.I.)
- Department of Medical and Biological Sciences, University of Udine, Via delle Scienze, 206, 33100 Udine, Italy
| | - Ciro Gargiulo Isacco
- Department of Interdisciplinary Medicine, University of Medicine Aldo Moro, 70124 Bari, Italy; (A.D.I.); (G.D.); (A.M.I.); (L.S.); (M.T.D.); (C.G.I.); (F.I.)
- Research at Human Stem Cells Research Center HSC, Ho Chi Minh 70000, Vietnam
- Embryology and Regenerative Medicine and Immunology, Pham Chau Trinh University of Medicine Hoi An, Hoi An 70000, Vietnam
| | - Ioana Roxana Bordea
- Department of Oral Rehabilitation, University of Medicine and Pharmacy “Iuliu Hatieganu”, 400012 Cluj-Napoca, Romania;
| | - Sebastian Candrea
- Department of Oral Rehabilitation, University of Medicine and Pharmacy “Iuliu Hatieganu”, 400012 Cluj-Napoca, Romania;
- Department of Pedodontics, County Hospital Cluj-Napoca, 400000 Cluj-Napoca, Romania
| | - Antonio Scarano
- Department of Innovative Technologies in Medicine and Dentistry, University of Chieti-Pescara, 66100 Chieti, Italy;
| | - Benedetta Morandi
- Department of Biomedical, Surgical and Dental Sciences, Università degli Studi di Milano, 20122 Milan, Italy; (B.M.); (M.D.F.); (M.F.); (G.M.T.); (S.T.)
- Dental Clinic, IRCCS Istituto Ortopedico Galeazzi, 20161 Milan, Italy
| | - Massimo Del Fabbro
- Department of Biomedical, Surgical and Dental Sciences, Università degli Studi di Milano, 20122 Milan, Italy; (B.M.); (M.D.F.); (M.F.); (G.M.T.); (S.T.)
- Dental Clinic, IRCCS Istituto Ortopedico Galeazzi, 20161 Milan, Italy
| | - Marco Farronato
- Department of Biomedical, Surgical and Dental Sciences, Università degli Studi di Milano, 20122 Milan, Italy; (B.M.); (M.D.F.); (M.F.); (G.M.T.); (S.T.)
- UOC Maxillo-Facial Surgery and Dentistry, Fondazione IRCCS Ca Granda, Ospedale Maggiore Policlinico, 20122 Milan, Italy
| | - Gianluca Martino Tartaglia
- Department of Biomedical, Surgical and Dental Sciences, Università degli Studi di Milano, 20122 Milan, Italy; (B.M.); (M.D.F.); (M.F.); (G.M.T.); (S.T.)
- UOC Maxillo-Facial Surgery and Dentistry, Fondazione IRCCS Ca Granda, Ospedale Maggiore Policlinico, 20122 Milan, Italy
| | - Mario Giosuè Balzanelli
- SET-118, Department of Pre-Hospital and Emergency-San Giuseppe Moscati Hospital, 74100 Taranto, Italy;
| | - Andrea Ballini
- Department of Biosciences, Biotechnologies and Biopharmaceutics, Campus Universitario, University of Bari, 70125 Bari, Italy;
- Department of Precision Medicine, University of Campania, 80138 Naples, Italy
| | - Ludovica Nucci
- Department of Medical-Surgical and Dental Specialties, University of Campania Luigi Vanvitelli, 80100 Naples, Italy;
| | - Felice Lorusso
- Department of Innovative Technologies in Medicine and Dentistry, University of Chieti-Pescara, 66100 Chieti, Italy;
| | - Silvio Taschieri
- Department of Biomedical, Surgical and Dental Sciences, Università degli Studi di Milano, 20122 Milan, Italy; (B.M.); (M.D.F.); (M.F.); (G.M.T.); (S.T.)
- Dental Clinic, IRCCS Istituto Ortopedico Galeazzi, 20161 Milan, Italy
- Department of Oral Surgery, Institute of Dentistry, I. M. Sechenov First Moscow State Medical University, 119146 Moscow, Russia
| | - Francesco Inchingolo
- Department of Interdisciplinary Medicine, University of Medicine Aldo Moro, 70124 Bari, Italy; (A.D.I.); (G.D.); (A.M.I.); (L.S.); (M.T.D.); (C.G.I.); (F.I.)
| |
Collapse
|
23
|
The Influence of the Implant Macrogeometry on Insertion Torque, Removal Torque, and Periotest Implant Primary Stability: A Mechanical Simulation on High-Density Artificial Bone. Symmetry (Basel) 2021. [DOI: 10.3390/sym13050776] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022] Open
Abstract
Background: The primary stability is a determinant clinical condition for the success of different dental implants macro-design in different bone density using a validated and repeatable in vitro technique employing solid rigid polyurethane blocks. Materials and Methods: Five implants 3.8 × 13 mm2 for each macro-design (i.e., IK—tapered; IC—cylindric; and IA—active blade shape) were positioned into 20- and 30- pounds per cubic foot (PCF) polyurethane blocks. Bucco-lingual (BL) and mesial-distal (MD) implant stability quotient score (ISQ) was assessed by resonance frequency analysis while, insertion/removal torques were evaluated by dynamometric ratchet. Results: IC implants shown better primary stability in terms of ISQ compared to IA and IK in lower density block (20 PCF), while IK was superior to IA in higher density (30 PCF). IC shown higher removal torque in 30-PCF compared to IA and IC. Conclusions: The study effectiveness on polyurethane artificial bone with isotropic symmetry structure showed that the implants macro-design might represent a key factor on primary stability, in particular on low-density alveolar bone. Clinicians should consider patients features and implant geometry during low-density jaws rehabilitation. Further investigations are needed to generalize these findings.
Collapse
|
24
|
Lorusso F, Conte R, Inchingolo F, Festa F, Scarano A. Survival Rate of Zygomatic Implants for Fixed Oral Maxillary Rehabilitations: A Systematic Review and Meta-Analysis Comparing Outcomes between Zygomatic and Regular Implants. Dent J (Basel) 2021; 9:dj9040038. [PMID: 33915748 PMCID: PMC8065623 DOI: 10.3390/dj9040038] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2021] [Revised: 03/16/2021] [Accepted: 03/22/2021] [Indexed: 12/15/2022] Open
Abstract
Background: Zygomatic implants have been proposed alone or in combination with premaxillary conventional implants for severe resorbed maxillary atrophy rehabilitation. The aim of the present investigation was to evaluate through a qualitative systematic review and meta-analysis the survival rate of zygomatic implants in conjunction with regular fixtures for maxillary rehabilitation. Methods: The article screening was conducted on the PubMed/Medline and EMBASE electronic databases according to the “Preferred Reporting Items for Systematic Reviews and Meta-Analyses” (PRISMA) guidelines. The scientific papers were included for qualitative analysis and risk-of-bias evaluation. Only the papers that included rehabilitation with zygomatic implants in combination with regular implants were considered for the meta-analysis comparative evaluation of the implant survival rate. Results: The paper search screened a total of 137 papers. After the initial screening, a total of 32 articles were considered for the qualitative analysis. There was a similar implant survival rate between zygomatic and premaxilla regular implants (p = 0.02; Z: 2.26). Conclusions: Zygomatic and conventional implants showed a high long-term survival rate for fixed maxillary rehabilitations, but few included studies reported the marginal bone loss after loading. Further studies are necessary to evaluate the pattern of marginal bone loss between zygomatic and conventional implants after long-term functional loading.
Collapse
Affiliation(s)
- Felice Lorusso
- Department of Innovative Technologies in Medicine & Dentistry and CAST, University of Chieti-Pescara, Via dei Vestini 31, 66100 Chieti, Italy; (F.L.); (F.F.)
| | | | - Francesco Inchingolo
- Department of Interdisciplinary Medicine, University of Bari “Aldo Moro”, 70121 Bari, Italy;
| | - Felice Festa
- Department of Innovative Technologies in Medicine & Dentistry and CAST, University of Chieti-Pescara, Via dei Vestini 31, 66100 Chieti, Italy; (F.L.); (F.F.)
| | - Antonio Scarano
- Department of Innovative Technologies in Medicine & Dentistry and CAST, University of Chieti-Pescara, Via dei Vestini 31, 66100 Chieti, Italy; (F.L.); (F.F.)
- Correspondence: ; Tel.: +39-0871-355-4084; Fax: +39-0871-355-4099
| |
Collapse
|
25
|
Inchingolo AD, Inchingolo AM, Bordea IR, Xhajanka E, Romeo DM, Romeo M, Zappone CMF, Malcangi G, Scarano A, Lorusso F, Isacco CG, Marinelli G, Contaldo M, Ballini A, Inchingolo F, Dipalma G. The Effectiveness of Osseodensification Drilling Protocol for Implant Site Osteotomy: A Systematic Review of the Literature and Meta-Analysis. MATERIALS 2021; 14:ma14051147. [PMID: 33671038 PMCID: PMC7957527 DOI: 10.3390/ma14051147] [Citation(s) in RCA: 22] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/11/2021] [Revised: 02/24/2021] [Accepted: 02/25/2021] [Indexed: 12/11/2022]
Abstract
Many different osteotomy procedures has been proposed in the literature for dental implant site preparation. The osseodensification is a drilling technique that has been proposed to improve the local bone quality and implant stability in poor density alveolar ridges. This technique determines an expansion of the implant site by increasing the density of the adjacent bone. The aim of the present investigation was to evaluate the effectiveness of the osseodensification technique for implant site preparation through a literature review and meta-analysis. The database electronic research was performed on PubMed (Medline) database for the screening of the scientific papers. A total of 16 articles have been identified suitable for the review and qualitative analysis—11 clinical studies (eight on animals, three on human subjects), four literature reviews, and one case report. The meta-analysis was performed to compare the bone-to-implant contact % (BIC), bone area fraction occupied % (BAFO), and insertion torque of clockwise and counter-clockwise osseodensification procedure in animal studies. The included articles reported a significant increase in the insertion torque of the implants positioned through the osseodensification protocol compared to the conventional drilling technique. Advantages of this new technique are important above all when the patient has a strong missing and/or low quantity of bone tissue. The data collected until the drafting of this paper detect an improvement when the osseodensification has been adopted if compared to the conventional technique. A significant difference in BIC and insertion torque between the clockwise and counter-clockwise osseodensification procedure was reported, with no difference in BAFO measurements between the two approaches. The effectiveness of the present study demonstrated that the osseodensification drilling protocol is a useful technique to obtain increased implant insertion torque and bone to implant contact (BIC) in vivo. Further randomized clinical studies are required to confirm these pieces of evidence in human studies.
Collapse
Affiliation(s)
- Alessio Danilo Inchingolo
- Department of Interdisciplinary Medicine, University of Medicine Aldo Moro, 70124 Bari, Italy; (A.D.I.); (A.M.I.); (D.M.R.); (M.R.); (C.M.F.Z.); (G.M.); (C.G.I.); (G.M.); (F.I.); (G.D.)
| | - Angelo Michele Inchingolo
- Department of Interdisciplinary Medicine, University of Medicine Aldo Moro, 70124 Bari, Italy; (A.D.I.); (A.M.I.); (D.M.R.); (M.R.); (C.M.F.Z.); (G.M.); (C.G.I.); (G.M.); (F.I.); (G.D.)
| | - Ioana Roxana Bordea
- Department of Oral Rehabilitation, Faculty of Dentistry, Iuliu Hațieganu University of Medicine and Pharmacy, 400012 Cluj-Napoca, Romania
- Correspondence: (I.R.B.); (F.L.); Tel.:+4-07-4491-9319 (I.R.B.); +39-087-1455-4100 (F.L.)
| | - Edit Xhajanka
- Department of Dental Prosthesis, University of Tirana, Nr 183 Tirana, Albania;
| | - Donato Mario Romeo
- Department of Interdisciplinary Medicine, University of Medicine Aldo Moro, 70124 Bari, Italy; (A.D.I.); (A.M.I.); (D.M.R.); (M.R.); (C.M.F.Z.); (G.M.); (C.G.I.); (G.M.); (F.I.); (G.D.)
- Freelancer Studio Dentistico Drs. Romeo, 75025 Policoro, Italy
| | - Mario Romeo
- Department of Interdisciplinary Medicine, University of Medicine Aldo Moro, 70124 Bari, Italy; (A.D.I.); (A.M.I.); (D.M.R.); (M.R.); (C.M.F.Z.); (G.M.); (C.G.I.); (G.M.); (F.I.); (G.D.)
- Freelancer Studio Dentistico Drs. Romeo, 75025 Policoro, Italy
| | - Carlo Maria Felice Zappone
- Department of Interdisciplinary Medicine, University of Medicine Aldo Moro, 70124 Bari, Italy; (A.D.I.); (A.M.I.); (D.M.R.); (M.R.); (C.M.F.Z.); (G.M.); (C.G.I.); (G.M.); (F.I.); (G.D.)
- Freelancer Studio Dentistico Drs. Romeo, 75025 Policoro, Italy
| | - Giuseppina Malcangi
- Department of Interdisciplinary Medicine, University of Medicine Aldo Moro, 70124 Bari, Italy; (A.D.I.); (A.M.I.); (D.M.R.); (M.R.); (C.M.F.Z.); (G.M.); (C.G.I.); (G.M.); (F.I.); (G.D.)
| | - Antonio Scarano
- Department of Medical, Oral and Biotechnological Sciences, University of Chieti-Pescara, 66100 Chieti, Italy;
| | - Felice Lorusso
- Department of Medical, Oral and Biotechnological Sciences, University of Chieti-Pescara, 66100 Chieti, Italy;
- Correspondence: (I.R.B.); (F.L.); Tel.:+4-07-4491-9319 (I.R.B.); +39-087-1455-4100 (F.L.)
| | - Ciro Gargiulo Isacco
- Department of Interdisciplinary Medicine, University of Medicine Aldo Moro, 70124 Bari, Italy; (A.D.I.); (A.M.I.); (D.M.R.); (M.R.); (C.M.F.Z.); (G.M.); (C.G.I.); (G.M.); (F.I.); (G.D.)
- Human Stem Cells Research Center HSC of Ho Chi Minh, Ho Chi Minh 70000, Vietnam
- Embryology and Regenerative Medicine and Immunology, Pham Chau Trinh University of Medicine Hoi An, Hoi An 70000, Vietnam
| | - Grazia Marinelli
- Department of Interdisciplinary Medicine, University of Medicine Aldo Moro, 70124 Bari, Italy; (A.D.I.); (A.M.I.); (D.M.R.); (M.R.); (C.M.F.Z.); (G.M.); (C.G.I.); (G.M.); (F.I.); (G.D.)
| | - Maria Contaldo
- Multidisciplinary Department of Medical-Surgical and Dental Specialties, University of Campania Luigi Vanvitelli, Via Luigi de Crecchio, 6, 80138 Naples, Italy;
| | - Andrea Ballini
- Department of Biosciences, Biotechnologies and Biopharmaceutics, Campus Universitario “Ernesto Quagliariello” University of Bari “Aldo Moro”, 70125 Bari, Italy;
- Department of Precision Medicine, University of Campania “Luigi Vanvitelli”, 80138 Naples, Italy
| | - Francesco Inchingolo
- Department of Interdisciplinary Medicine, University of Medicine Aldo Moro, 70124 Bari, Italy; (A.D.I.); (A.M.I.); (D.M.R.); (M.R.); (C.M.F.Z.); (G.M.); (C.G.I.); (G.M.); (F.I.); (G.D.)
| | - Gianna Dipalma
- Department of Interdisciplinary Medicine, University of Medicine Aldo Moro, 70124 Bari, Italy; (A.D.I.); (A.M.I.); (D.M.R.); (M.R.); (C.M.F.Z.); (G.M.); (C.G.I.); (G.M.); (F.I.); (G.D.)
| |
Collapse
|
26
|
Comuzzi L, Tumedei M, De Angelis F, Lorusso F, Piattelli A, Iezzi G. Influence of the dental implant macrogeometry and threads design on primary stability: an in vitro simulation on artificial bone blocks. Comput Methods Biomech Biomed Engin 2021; 24:1242-1250. [PMID: 33492988 DOI: 10.1080/10255842.2021.1875219] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
The implant macrogeometry and thread profile represent one of the most important factors for a successful achievement of primary stability during the positioning procedure. The aim of the present investigation was to evaluate the insertion torque (IT), removal torque (RT) and Implant stability Quotient (ISQ) of two different implant macrogeometry and thread profile on solid rigid polyurethane model. Two different implants macrogeometries were tested: K2 (Group I) with 11° angle, 1.17 mm pitch and self-cutting V thread profile and K3 (Group II) implants with 30° angle, 0.71 mm pitch and spyral thread profile. A total of 120 specimens (n = 60 for each group) were positioned into different conditions of solid rigid polyurethane blocks. The insertion torque (IT), removal torque (RT) and ISQ were measured for each specimen. All specimens achieved the positioning into solid rigid polyurethane blocks for both of groups with no loss of stability. A significantly higher IT, RT and ISQ were detected in Group II (p < 0.05). In both groups the mean values for IT, RT and ISQ appeared promising from a clinical point of view. In spite of different macrogeometry and thread profile, both implant types achieved high primary stability on solid rigid polyurethane block to support the functional loading for a clinical application.
Collapse
Affiliation(s)
- Luca Comuzzi
- Private Practice, San Vendemiano-Conegliano (Treviso), Italy
| | - Margherita Tumedei
- Department of Medical, Oral and Biotechnological Sciences, University "G. D'Annunzio" of Chieti-Pescara, Chieti, Italy
| | - Francesco De Angelis
- Department of Medical, Oral and Biotechnological Sciences, University "G. D'Annunzio" of Chieti-Pescara, Chieti, Italy
| | - Felice Lorusso
- Department of Medical, Oral and Biotechnological Sciences, University "G. D'Annunzio" of Chieti-Pescara, Chieti, Italy
| | - Adriano Piattelli
- Department of Medical, Oral and Biotechnological Sciences, University "G. D'Annunzio" of Chieti-Pescara, Chieti, Italy.,Biomaterials Engineering, Catholic University of San Antonio de Murcia (UCAM), Guadalupe, Murcia, Spain.,Villaserena Foundation for Research, Città Sant'Angelo (PE), Italy
| | - Giovanna Iezzi
- Department of Medical, Oral and Biotechnological Sciences, University "G. D'Annunzio" of Chieti-Pescara, Chieti, Italy
| |
Collapse
|
27
|
Lorusso F, Noumbissi S, Francesco I, Rapone B, Khater AGA, Scarano A. Scientific Trends in Clinical Research on Zirconia Dental Implants: A Bibliometric Review. MATERIALS 2020; 13:ma13235534. [PMID: 33291827 PMCID: PMC7730252 DOI: 10.3390/ma13235534] [Citation(s) in RCA: 33] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/18/2020] [Revised: 11/29/2020] [Accepted: 12/02/2020] [Indexed: 12/13/2022]
Abstract
Background: The clinical use of zirconia implants has been shown to increase steadily due to their biological, aesthetic, and physical properties; therefore, this bibliometric study aimed to review the clinical research and co-authors in the field of zirconia dental implant rehabilitation. Methods: We searched Scopus and Web of Science databases using a comprehensive search strategy to 5 October 2020, and independently paired reviewers who screened studies, and collected data with inclusion criteria restricted to clinical research only (either prospective or retrospective). Data on article title, co-authors, number of citations received, journal details, publication year, country and institution involved, funding, study design, marginal bone loss, survival rate, failure, follow-up, and the author’s bibliometric data were collected and evaluated. Results: A total of 29 clinical studies were published between 2008 and 2020 as 41.4% were prospective cohort studies and 48.3% originated from Germany. Most of the included studies had been published in Clinical Oral Implant Research (n = 12), and the most productive institution was the Medical Center of University of Freiburg. The author with the largest number of clinical studies on zirconia implants was Kohal R.J. (n = 10), followed by Spies B.C. (n = 8). Conclusions: This study revealed that zirconia implants have been more prominent in the last ten years, which is a valuable option for oral rehabilitation with marginal bone loss and survival rate comparable to titanium dental implants.
Collapse
Affiliation(s)
- Felice Lorusso
- Department of Medical, Oral and Biotechnological Sciences, University of Chieti-Pescara, Via dei Vestini, 31, 66100 Chieti, Italy; (F.L.); (S.N.)
- Zirconia Implant Research Group (Z.I.R.G), International Academy of Ceramic Implantology, Silver Spring, MD 20910, USA
| | - Sammy Noumbissi
- Department of Medical, Oral and Biotechnological Sciences, University of Chieti-Pescara, Via dei Vestini, 31, 66100 Chieti, Italy; (F.L.); (S.N.)
- Zirconia Implant Research Group (Z.I.R.G), International Academy of Ceramic Implantology, Silver Spring, MD 20910, USA
| | - Inchingolo Francesco
- Department of Interdisciplinary Medicine, University of Bari Aldo Moro, 70121 Bari, Italy;
| | - Biagio Rapone
- Department of Basic Medical Sciences, Neurosciences and Sense Organs, University of Bari Aldo Moro, 70121 Bari, Italy;
| | - Ahmad G. A. Khater
- Faculty of Oral and Dental Medicine, Ahram Canadian University, 6th of October City, 8655 Giza, Egypt;
| | - Antonio Scarano
- Department of Medical, Oral and Biotechnological Sciences, University of Chieti-Pescara, Via dei Vestini, 31, 66100 Chieti, Italy; (F.L.); (S.N.)
- Zirconia Implant Research Group (Z.I.R.G), International Academy of Ceramic Implantology, Silver Spring, MD 20910, USA
- Correspondence: ; Tel.: +39-0871-355-4084; Fax: +39-0871-355-4099
| |
Collapse
|
28
|
Can Bone Compaction Improve Primary Implant Stability? An In Vitro Comparative Study with Osseodensification Technique. APPLIED SCIENCES-BASEL 2020. [DOI: 10.3390/app10238623] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
Background: This study aims to analyze bone compaction and osseodensification techniques and to investigate how cancellous bone compaction could influence primary implant stability (PS). Methods: Two different surgical protocols (bone compactors—BC; osseodensification drills—OD) were compared by placing 20 implants into 20 fresh pig ribs for each procedure. Peak insertion torque (PIT) and peak removal torque (PRT) were investigated using an MGT-12 digital torque gauge, and implant stability quotient (ISQ) was analyzed using an Osstell® Beacon device. Results: Analysis of our data (T-test p < 0.05) evidenced no statistically significant difference between BC and OD in terms of PIT (p = 0.33) or ISQ (p = 0.97). The comparison of PRT values showed a statistically significant difference between BC and OD protocols (p = 0.009). Conclusions: Cancellous bone compaction seems to improve PS, preserving a significant amount of bone and evenly spreading trabeculae on the entire implant site. While the PIT and ISQ values obtained are similar, the PRT values suggest different physical responses from the surrounding bone tissue. Nevertheless, a larger sample and further in vivo studies are necessary to validate the usefulness of BC protocol in several clinical settings.
Collapse
|