Guzman NA, Guzman DE, Blanc T. Advancements in portable instruments based on affinity-capture-migration and affinity-capture-separation for use in clinical testing and life science applications. J Chromatogr A 2023; 1704:464109. [PMID: 37315445 DOI: 10.1016/j.chroma.2023.464109] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2023] [Revised: 05/23/2023] [Accepted: 05/25/2023] [Indexed: 06/16/2023]
Abstract
The shift from testing at centralized diagnostic laboratories to remote locations is being driven by the development of point-of-care (POC) instruments and represents a transformative moment in medicine. POC instruments address the need for rapid results that can inform faster therapeutic decisions and interventions. These instruments are especially valuable in the field, such as in an ambulance, or in remote and rural locations. The development of telehealth, enabled by advancements in digital technologies like smartphones and cloud computing, is also aiding in this evolution, allowing medical professionals to provide care remotely, potentially reducing healthcare costs and improving patient longevity. One notable POC device is the lateral flow immunoassay (LFIA), which played a major role in addressing the COVID-19 pandemic due to its ease of use, rapid analysis time, and low cost. However, LFIA tests exhibit relatively low analytical sensitivity and provide semi-quantitative information, indicating either a positive, negative, or inconclusive result, which can be attributed to its one-dimensional format. Immunoaffinity capillary electrophoresis (IACE), on the other hand, offers a two-dimensional format that includes an affinity-capture step of one or more matrix constituents followed by release and electrophoretic separation. The method provides greater analytical sensitivity, and quantitative information, thereby reducing the rate of false positives, false negatives, and inconclusive results. Combining LFIA and IACE technologies can thus provide an effective and economical solution for screening, confirming results, and monitoring patient progress, representing a key strategy in advancing diagnostics in healthcare.
Collapse
Affiliation(s)
- Norberto A Guzman
- Princeton Biochemicals, Inc., Princeton, NJ 08543, United States of America.
| | - Daniel E Guzman
- Princeton Biochemicals, Inc., Princeton, NJ 08543, United States of America; Columbia University Irving Medical Center, New York, NY 10032, United States of America
| | - Timothy Blanc
- Eli Lilly and Company, Branchburg, NJ 08876, United States of America
| |
Collapse
|
2
|
Shimura K, Nagai T. Capillary isoelectric focusing after sample enrichment with immunoaffinity chromatography in a single capillary. Sci Rep 2016; 6:39221. [PMID: 27976690 PMCID: PMC5156949 DOI: 10.1038/srep39221] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2016] [Accepted: 11/21/2016] [Indexed: 11/12/2022] Open
Abstract
For accurate micro-scale quantification of a specific protein in biological fluids, immunoaffinity chromatography (IAC) and isoelectric focusing (IEF) were combined in a single fused-silica capillary. The inner wall of the capillary was coated with an anti-E-tag antibody at the inlet side to form an IAC column, and polydimethylacrylamide, a neutral polymer, at the outlet side to form the capillary for IEF. After loading a sample, the whole capillary was filled with a carrier ampholyte solution. An anode solution, an acid, was then introduced to fill only the IAC column segment. Focusing was started with a pressure that balances with the electroosmotic flow produced in the acidified IAC column. Fluorescence-labeled recombinant Fab with an E-tag spiked at 16 pM to 10 nM in 50% serum was separated and detected with high precision. The coupling principle allows rapid and high-resolution IEF analysis of a protein in a biological sample without any loss of the immunoaffinity captured protein.
Collapse
Affiliation(s)
- Kiyohito Shimura
- Division of Advanced Chemistry, Fukushima Medical University, 1 Hikarigaoka, Fukushima, 960-1295, Japan
| | - Toshihiko Nagai
- Division of Advanced Chemistry, Fukushima Medical University, 1 Hikarigaoka, Fukushima, 960-1295, Japan
| |
Collapse
|
3
|
Guzman NA, Guzman DE. An emerging micro-scale immuno-analytical diagnostic tool to see the unseen. Holding promise for precision medicine and P4 medicine. J Chromatogr B Analyt Technol Biomed Life Sci 2016; 1021:14-29. [DOI: 10.1016/j.jchromb.2015.11.026] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2015] [Revised: 11/15/2015] [Accepted: 11/17/2015] [Indexed: 01/10/2023]
|
4
|
Zhang Z, Sun L, Zhu G, Yan X, Dovichi NJ. Integrated strong cation-exchange hybrid monolith coupled with capillary zone electrophoresis and simultaneous dynamic pH junction for large-volume proteomic analysis by mass spectrometry. Talanta 2015; 138:117-122. [PMID: 25863379 PMCID: PMC4394190 DOI: 10.1016/j.talanta.2015.01.040] [Citation(s) in RCA: 40] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2014] [Revised: 01/28/2015] [Accepted: 01/29/2015] [Indexed: 10/24/2022]
Abstract
A sulfonate-silica hybrid strong cation-exchange (SCX) monolith was synthesized at the proximal end of a capillary zone electrophoresis column and used for on-line solid-phase extraction (SPE) sample preconcentration. Sample was prepared in an acidic buffer and deposited onto the SCX-SPE monolith and eluted using a basic buffer. Electrophoresis was performed in an acidic buffer. This combination of buffers results in formation of a dynamic pH junction, which allows use of relatively large elution buffer volume while maintaining peak efficiency and resolution. All experiments were performed with a 50 µm ID capillary, a 1cm long SCX-SPE monolith, a 60cm long separation capillary, and a electrokinetically pumped nanospray interface. The volume of the capillary is 1.1 µL. By loading 21 µL of a 1×10(-7) M angiotensin II solution, an enrichment factor of 3000 compared to standard electrokinetic injection was achieved on this platform while retaining efficient electrophoretic performance (N=44,000 plates). The loading capacity of the sulfonate SCX hybrid monolith was determined to be ~15 pmol by frontal analysis with 10(-5) M angiotensin II. The system was also applied to the analysis of a 10(-4) mg/mL bovine serum albumin tryptic digest; the protein coverage was 12% and 11 peptides were identified. Finally, by loading 5.5 µL of a 10(-3) mg/mL E. coli digest, 109 proteins and 271 peptides were identified in a 20 min separation; the median separation efficiency generated by these peptides was 25,000 theoretical plates.
Collapse
Affiliation(s)
- Zhenbin Zhang
- Department of Chemistry and Biochemistry, University of Notre Dame, Notre Dame, IN 46556 USA
| | - Liangliang Sun
- Department of Chemistry and Biochemistry, University of Notre Dame, Notre Dame, IN 46556 USA
| | - Guijie Zhu
- Department of Chemistry and Biochemistry, University of Notre Dame, Notre Dame, IN 46556 USA
| | - Xiaojing Yan
- Department of Chemistry and Biochemistry, University of Notre Dame, Notre Dame, IN 46556 USA
| | - Norman J Dovichi
- Department of Chemistry and Biochemistry, University of Notre Dame, Notre Dame, IN 46556 USA.
| |
Collapse
|
5
|
Shimura K, Nagai T. Direct coupling of immobilized metal ion affinity chromatography and capillary isoelectric focusing in a single capillary. ACTA ACUST UNITED AC 2015. [DOI: 10.2198/jelectroph.59.7] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Affiliation(s)
- Kiyohito Shimura
- Division of Advanced Chemistry, School of Medicine, Fukushima Medical University
| | - Toshihiko Nagai
- Division of Advanced Chemistry, School of Medicine, Fukushima Medical University
| |
Collapse
|
6
|
Breadmore MC, Dawod M, Quirino JP. Recent advances in enhancing the sensitivity of electrophoresis and electrochromatography in capillaries and microchips (2008-2010). Electrophoresis 2010; 32:127-48. [PMID: 21171119 DOI: 10.1002/elps.201000412] [Citation(s) in RCA: 129] [Impact Index Per Article: 9.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2010] [Revised: 09/15/2010] [Accepted: 09/16/2010] [Indexed: 01/22/2023]
Abstract
Capillary electrophoresis has been alive for over two decades now; yet, its sensitivity is still regarded as being inferior to that of more traditional methods of separation such as HPLC. As such, it is unsurprising that overcoming this issue still generates much scientific interest. This review continues to update this series of reviews, first published in Electrophoresis in 2007, with an update published in 2009 and covers material published through to June 2010. It includes developments in the fields of stacking, covering all methods from field-amplified sample stacking and large volume sample stacking, through to ITP, dynamic pH junction and sweeping. Attention is also given to on-line or in-line extraction methods that have been used for electrophoresis.
Collapse
Affiliation(s)
- Michael C Breadmore
- Australian Centre for Research on Separation Science, School of Chemistry, University of Tasmania, Hobart, TAS, Australia.
| | | | | |
Collapse
|
7
|
Vizioli N, Gil R, Martínez LD, Fernanda Silva M. On-line solid phase extraction CZE for the simultaneous determination of lanthanum and gadolinium at picogram per liter levels. Electrophoresis 2009; 30:2681-7. [DOI: 10.1002/elps.200800819] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
8
|
Chen HX, Busnel JM, Peltre G, Zhang XX, Girault HH. Magnetic Beads Based Immunoaffinity Capillary Electrophoresis of Total Serum IgE with Laser-Induced Fluorescence Detection. Anal Chem 2008; 80:9583-8. [DOI: 10.1021/ac801859e] [Citation(s) in RCA: 43] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- Hong-Xu Chen
- Laboratoire d’Electrochimie Physique et Analytique, Station 6, Ecole Polytechnique Fédérale de Lausanne, CH-1015 Lausanne, Switzerland, Beijing National Laboratory for Molecular Sciences, College of Chemistry, Peking University, Beijing 100871, China, and Laboratoire Environnement et Chimie Analytique, UMR CNRS 7121, ESPCI, Paris, France
| | - Jean-Marc Busnel
- Laboratoire d’Electrochimie Physique et Analytique, Station 6, Ecole Polytechnique Fédérale de Lausanne, CH-1015 Lausanne, Switzerland, Beijing National Laboratory for Molecular Sciences, College of Chemistry, Peking University, Beijing 100871, China, and Laboratoire Environnement et Chimie Analytique, UMR CNRS 7121, ESPCI, Paris, France
| | - Gabriel Peltre
- Laboratoire d’Electrochimie Physique et Analytique, Station 6, Ecole Polytechnique Fédérale de Lausanne, CH-1015 Lausanne, Switzerland, Beijing National Laboratory for Molecular Sciences, College of Chemistry, Peking University, Beijing 100871, China, and Laboratoire Environnement et Chimie Analytique, UMR CNRS 7121, ESPCI, Paris, France
| | - Xin-Xiang Zhang
- Laboratoire d’Electrochimie Physique et Analytique, Station 6, Ecole Polytechnique Fédérale de Lausanne, CH-1015 Lausanne, Switzerland, Beijing National Laboratory for Molecular Sciences, College of Chemistry, Peking University, Beijing 100871, China, and Laboratoire Environnement et Chimie Analytique, UMR CNRS 7121, ESPCI, Paris, France
| | - Hubert H. Girault
- Laboratoire d’Electrochimie Physique et Analytique, Station 6, Ecole Polytechnique Fédérale de Lausanne, CH-1015 Lausanne, Switzerland, Beijing National Laboratory for Molecular Sciences, College of Chemistry, Peking University, Beijing 100871, China, and Laboratoire Environnement et Chimie Analytique, UMR CNRS 7121, ESPCI, Paris, France
| |
Collapse
|
9
|
Chaisuwan P, Nacapricha D, Wilairat P, Jiang Z, William Smith N. Monolithic and packed particle materials for in-line pre-concentration in capillary electrophoresis for 4-hydroxy-3-methoxy-methamphetamine and terbutaline. Electrophoresis 2008; 29:4008-16. [DOI: 10.1002/elps.200700915] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
10
|
Guzman NA, Blanc T, Phillips TM. Immunoaffinity capillary electrophoresis as a powerful strategy for the quantification of low-abundance biomarkers, drugs, and metabolites in biological matrices. Electrophoresis 2008; 29:3259-78. [PMID: 18646282 PMCID: PMC2659498 DOI: 10.1002/elps.200800058] [Citation(s) in RCA: 76] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
Abstract
In the last few years, there has been a greater appreciation by the scientific community of how separation science has contributed to the advancement of biomedical research. Despite past contributions in facilitating several biomedical breakthroughs, separation sciences still urgently need the development of improved methods for the separation and detection of biological and chemical substances. In particular, the challenging task of quantifying small molecules and biomolecules, found in low abundance in complex matrices (e.g., serum), is a particular area in need of new high-efficiency techniques. The tandem or on-line coupling of highly selective antibody capture agents with the high-resolving power of CE is being recognized as a powerful analytical tool for the enrichment and quantification of ultra-low abundance analytes in complex matrices. This development will have a significant impact on the identification and characterization of many putative biomarkers and on biomedical research in general. Immunoaffinity CE (IACE) technology is rapidly emerging as the most promising method for the analysis of low-abundance biomarkers; its power comes from a three-step procedure: (i) bioselective adsorption and (ii) subsequent recovery of compounds from an immobilized affinity ligand followed by (iii) separation of the enriched compounds. This technology is highly suited to automation and can be engineered to as a multiplex instrument capable of routinely performing hundreds of assays per day. Furthermore, a significant enhancement in sensitivity can be achieved for the purified and enriched affinity targeted analytes. Thus, a compound that exists in a complex biological matrix at a concentration far below its LOD is easily brought to well within its range of quantification. The present review summarizes several applications of IACE, as well as a chronological description of the improvements made in the fabrication of the analyte concentrator-microreactor device leading to the development of a multidimensional biomarker analyzer.
Collapse
Affiliation(s)
- Norberto A Guzman
- Biomarker Laboratory, Princeton Biochemicals, Inc., Princeton, NJ 08543, USA.
| | | | | |
Collapse
|
11
|
Tempels FWA, Underberg WJM, Somsen GW, de Jong GJ. Design and applications of coupled SPE-CE. Electrophoresis 2008; 29:108-28. [DOI: 10.1002/elps.200700149] [Citation(s) in RCA: 46] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
|
12
|
Breadmore MC. Recent advances in enhancing the sensitivity of electrophoresis and electrochromatography in capillaries and microchips. Electrophoresis 2007; 28:254-81. [PMID: 17149782 DOI: 10.1002/elps.200600463] [Citation(s) in RCA: 160] [Impact Index Per Article: 9.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
Poor sensitivity is considered to be one of the major limitations of electrophoretic separation methods, particularly when compared to traditional liquid chromatographic techniques. To address this issue, various in-line preconcentration techniques have been developed over the past 15 years, ranging in power and complexity, and there are now a number of well understood approaches routinely capable of providing a 10,000- to 100,000-fold increase in sensitivity, as well as several that can be pushed above a million. Furthermore, these have been achieved with particularly troublesome and often difficult samples, such as those having high salinity from a biological or environmental origin. This review will discuss the most common methods for improving the sensitivity of CE, CEC and microchip version of these, with particular attention to those approaches developed over the last five years.
Collapse
Affiliation(s)
- Michael C Breadmore
- Australian Centre for Research on Separation Science, School of Chemistry, University of Tasmania, Hobart, Tasmania, Australia.
| |
Collapse
|
13
|
Benavente F, Vescina MC, Hernández E, Sanz-Nebot V, Barbosa J, Guzman NA. Lowering the concentration limits of detection by on-line solid-phase extraction–capillary electrophoresis–electrospray mass spectrometry. J Chromatogr A 2007; 1140:205-12. [PMID: 17174962 DOI: 10.1016/j.chroma.2006.11.092] [Citation(s) in RCA: 60] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2006] [Revised: 11/23/2006] [Accepted: 11/29/2006] [Indexed: 01/22/2023]
Abstract
The use of solid-phase extraction coupled on-line to capillary electrophoresis using electrospray mass spectrometry detection (SPE-CE-ESI-MS) is described for the analysis of peptides in dilute solutions. A SPE microcartridge or analyte concentrator containing C(18) derivatized silica particles as the extraction sorbent was easily constructed near the inlet of the separation capillary using commercially available materials. The reversed-phase sorbent selectively retained the target peptides, enabling large volumes of the sample to be introduced (>100muL). The captured analytes were eluted in a small volume of an appropriate solution (20-50nL). This resulted in sample clean-up and concentration enhancement, with minimum sample handling. As the SPE-CE conditions were compatible with on-line ESI-MS detection, the potential for identifying and characterizing the preconcentrated analytes by SPE-CE-ESI-MS using a sheath-flow CE-ESI-MS interface is also shown. Using separation electrolytes containing N-[carbamoylmethyl]-2-aminoethanesulfonic acid (ACES) at pH 7.4, an elution plug of 80:20 (v/v) (25mM of formic acid in MeCN):H(2)O and a sheath liquid of 20mM of acetic acid in 50:50 (v/v) methanol:H(2)O the concentration limits of detection for the analyzed peptides in the positive ion mode were lowered to nanogram per milliliter levels. The systematic optimization of the operational parameters involved in the development of the SPE-CE method is described in detail, in order to promote robust and quantitative SPE-CE-ESI-MS analysis and facilitate the widespread use of the technique.
Collapse
Affiliation(s)
- Fernando Benavente
- Department of Analytical Chemistry, University of Barcelona, Diagonal 647, 08028 Barcelona, Spain.
| | | | | | | | | | | |
Collapse
|
14
|
Armenta JM, Gu B, Humble PH, Thulin CD, Lee ML. Design and evaluation of a coupled monolithic preconcentrator-capillary zone electrophoresis system for the extraction of immunoglobulin G from human serum. J Chromatogr A 2005; 1097:171-8. [PMID: 16298197 DOI: 10.1016/j.chroma.2005.08.050] [Citation(s) in RCA: 45] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2005] [Revised: 08/01/2005] [Accepted: 08/08/2005] [Indexed: 11/19/2022]
Abstract
The analysis of proteins in biological fluids by capillary electrophoresis (CE) is of interest in clinical chemistry. However, due to low analyte concentrations and poor concentration limits of detection (CLOD), protein analysis by this technique is frequently challenging. Coupling preconcentration techniques with CE greatly improves the CLOD. An on-line preconcentration-CE method that can selectively pre-concentrate any protein for which an antibody is available would be very useful for the analysis of low abundance proteins and would establish CE as a major tool in biomarker discovery. To accomplish this, the development of an on-line protein G monolithic pre-concentrator-CE device is proposed. To generate active groups for protein immobilization, glycidyl methacrylate (GMA) was used to prepare polymer monoliths. A 1.5-2 cm monolith was cast inside a 75 microm I.D. fused silica capillary that had previously been coated with alternating layers of negatively (dextran) and positively (polybrene) charged polymers. Protein G was covalently bound to GMA. Monoliths from different formulations were prepared and evaluated for binding capacity to optimize the monolith formulation for protein preconcentration. The physical properties of the column considered best for preconcentration were determined by mercury intrusion porosimetry. The total pore area was 4.8m(2)/g, the average pore diameter was 3.3 microm and the porosity was 82%. The monolith had a low flow resistance and was macroscopically homogeneous. The effectiveness of the monolith to rapidly pre-concentrate proteins at flow rates as high as 10 microL/min was demonstrated using a 1.8 microM IgG solution. This system proved effective for on-line sample extraction, clean-up, preconcentration, and CE of IgG in human serum. IgG from diluted (500 and 65,000 times) human serum samples was successfully analyzed using this system. The approach can be applied to the on-line preconcentration and analysis of any protein for which an antibody is available.
Collapse
Affiliation(s)
- Jenny M Armenta
- Department of Chemistry and Biochemistry, C267 Benson Science Building, Brigham Young University, P.O. Box 25700, Provo, UT 84602-5700, USA
| | | | | | | | | |
Collapse
|
15
|
Vizioli NM, Rusell ML, Carbajal ML, Carducci CN, Grasselli M. On-line affinity selection of histidine-containing peptides using a polymeric monolithic support for capillary electrophoresis. Electrophoresis 2005; 26:2942-8. [PMID: 16007696 DOI: 10.1002/elps.200410416] [Citation(s) in RCA: 49] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
An on-line affinity selection method using a polymeric monolithic support is proposed for the retention of histidine-containing peptides and their subsequent separation by capillary zone electrophoresis (CZE). Monolithic capillary columns were prepared in fused-silica capillaries of 150 mum inner diameter (ID) by ionizing radiation-initiated in situ polymerization and cross-linking of diethylene glycol dimethacrylate and glycidyl methacrylate, and chemically modified with iminodiacetic acid (IDA) and copper ion. Monolithic microextractors were coupled on-line near the inlet of the separation capillary (fused-silica capillary, 75 mum ID x 28 cm from the microextractor to the detector). Model peptide mixtures of histidine-containing and histidine-noncontaining peptides were assessed. Peptides were released from the sorbent by a 5 mM imidazole solution and then separated by CZE with ultraviolet detection. Relative standard deviation values for migration times and corrected peak areas were found to be lower than 5.8 and 10.5%, respectively. IDA-Cu(II) ion modified monolithic microextractors showed a chromatographic behavior and could be reused at least 25 times. The use of monolithic supports proved to be an advantageous alternative to packed particles for the preparation of microextractors.
Collapse
Affiliation(s)
- Nora M Vizioli
- Department of Analytical Chemistry and Physicochemistry, Faculty of Pharmacy and Biochemistry, University of Buenos Aires, Argentina.
| | | | | | | | | |
Collapse
|
16
|
Tempels FWA, Underberg WJM, Somsen GW, de Jong GJ. Chromatographic Preconcentration Coupled To Capillary Electrophoresis via an In-Line Injection Valve. Anal Chem 2004; 76:4432-6. [PMID: 15283584 DOI: 10.1021/ac0499221] [Citation(s) in RCA: 37] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
A preconcentration-capillary electrophoresis (CE) system using a small precolumn in combination with an in-line injection valve is presented. The advantage of the present design is the ability to perform the sample preconcentration fully independently from the CE separation and to prevent sample matrix and washing solvents from entering the CE capillary. With a micro injection valve, sample could be effectively introduced into the CE system in an in-line fashion without seriously affecting the CE separation efficiency. Breakthrough volume, desorption efficiency, and elution volume for the C18 microcolumn (5 x 0.5 mm i.d.) were established, yielding values of 750 microL, 70%, and 0.9-1.1 microL, respectively, using enkephalin peptides. The time between the start of the desorption of the analytes from the precolumn and the injection into the CE system was also studied in order to achieve optimal sensitivity and separation efficiency. The performance of the complete system was demonstrated by the preconcentration and separation of an enkephalin mixture. Using a sample volume of 250 microL and a CE injection voltage of -15 kV for 12 s, linearity was observed over 2 orders of magnitude, and detection limits (S/N = 3) were in the 5-10 ng/mL range. A 1000-fold sensitivity enhancement is obtained using this setup, as compared to a regular CE setup. For 100 ng/mL samples, repeatabilities (RSDs) of migration time and peak area were 1.2 and 11%, respectively.
Collapse
Affiliation(s)
- F W Alexander Tempels
- Department of Biomedical Analysis, Faculty of Pharmaceutical Sciences, Utrecht University, Sorbonnelaan 16, NL-3584 CA Utrecht, The Netherlands
| | | | | | | |
Collapse
|
17
|
Clarke W, Hage DS. Clinical Applications of Affinity Chromatography. SEPARATION AND PURIFICATION REVIEWS 2003. [DOI: 10.1081/spm-120025025] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
|
18
|
|
19
|
Guzman NA, Stubbs RJ. The use of selective adsorbents in capillary electrophoresis-mass spectrometry for analyte preconcentration and microreactions: a powerful three-dimensional tool for multiple chemical and biological applications. Electrophoresis 2001; 22:3602-28. [PMID: 11699899 DOI: 10.1002/1522-2683(200109)22:17<3602::aid-elps3602>3.0.co;2-x] [Citation(s) in RCA: 92] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Much attention has recently been directed to the development and application of online sample preconcentration and microreactions in capillary electrophoresis using selective adsorbents based on chemical or biological specificity. The basic principle involves two interacting chemical or biological systems with high selectivity and affinity for each other. These molecular interactions in nature usually involve noncovalent and reversible chemical processes. Properly bound to a solid support, an "affinity ligand" can selectively adsorb a "target analyte" found in a simple or complex mixture at a wide range of concentrations. As a result, the isolated analyte is enriched and highly purified. When this affinity technique, allowing noncovalent chemical interactions and biochemical reactions to occur, is coupled on-line to high-resolution capillary electrophoresis and mass spectrometry, a powerful tool of chemical and biological information is created. This paper describes the concept of biological recognition and affinity interaction on-line with high-resolution separation, the fabrication of an "analyte concentrator-microreactor", optimization conditions of adsorption and desorption, the coupling to mass spectrometry, and various applications of clinical and pharmaceutical interest.
Collapse
Affiliation(s)
- N A Guzman
- Bioanalytical Drug Metabolism, The R. W. Johnson Pharmaceutical Research Institute, Raritan, NJ 08869, USA.
| | | |
Collapse
|
20
|
Breadmore MC, Haddad PR. Approaches to enhancing the sensitivity of capillary electrophoresis methods for the determination of inorganic and small organic anions. Electrophoresis 2001; 22:2464-89. [PMID: 11519951 DOI: 10.1002/1522-2683(200107)22:12<2464::aid-elps2464>3.0.co;2-u] [Citation(s) in RCA: 82] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
One of the major problems facing the development of capillary electrophoresis (CE) is the relatively high limits of detection when compared to traditional high-performance liquid chromatographic (HPLC) methods. While the use of an alternative detector can offer better sensitivity, a more universal approach is sample preconcentration. Numerous on-line methods have been developed to improve the sensitivity of CE, and are based on electrophoretic principles, chromatographic principles, or a combination of both. This review will discuss all forms of on-line preconcentration methods for CE, with emphasis given to those that have shown particular merit when applied to inorganic and small organic anions.
Collapse
Affiliation(s)
- M C Breadmore
- Australian Centre for Research on Separation Science, School of Chemistry, University of Tasmania, Hobart
| | | |
Collapse
|
21
|
Abstract
One of the weak points of capillary electrophoresis is the need to implement rigorously sample pretreatment because its great impact on the quality of the qualitative and quantitative results provided. One of the approaches to solve this problem is through the symbiosis of automatic continuous flow systems (CFSs) and capillary electrophoresis (CE). In this review a systematic approach to CFS-CE coupling is presented and discussed. The design of the corresponding interface depends on three factors, namely: (a) the characteristics of the CFS involved which can be non-chromatographic and chromatographic; (b) the type of CE equipment: laboratory-made or commercially available; and (c) the type of connection which can be in-line (on-capillary), on-line or mixed off/on-line. These are the basic criteria to qualify the hyphenation of CFS (solid-phase extraction, dialysis, gas diffusion, evaporation, direct leaching) with CE described so far and applied to determine a variety of analytes in many different types of samples. A critical discussion allows one to demonstrate that this symbiosis is an important topic in research and development, besides separation and detection, to consolidate CE as a routine analytical tool.
Collapse
Affiliation(s)
- M Valcárcel
- Analytical Chemistry Division, University of Córdoba, Spain.
| | | | | |
Collapse
|
22
|
Breadmore MC, Macka M, Avdalovic N, Haddad PR. On-capillary ion-exchange preconcentration of inorganic anions in open-tubular capillary electrochromatogrpahy with elution using transient-isotachophoretic gradient. 2. Characterization of the isotachophoretic gradient. Anal Chem 2001; 73:820-8. [PMID: 11248899 DOI: 10.1021/ac0010577] [Citation(s) in RCA: 53] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Diffuse transient-isotachophoretic boundaries can be used as an elution gradient of increasing eluotropic strength to elute inorganic anions that have been preconcentrated on an open-tubular ion-exchange stationary phase prior to electrophoretic separation. The generation and characteristics of these gradients for elution after preconcentration have been investigated. The gradients are generated by placing a low-mobility, weak ion-exchange competing anion in the capillary (weak electrolyte, WE), and a high-mobility, strong ion-exchange competing anion in the electrolyte vials (strong electrolyte, SE). Application of voltage establishes a diffuse boundary with the composition changing from the weak anion to the strong anion. Comparison of elution gradients generated with different electrolyte systems was accomplished by comparing the eluotropic strength (a function of eluent concentration, ion-exchange selectivity coefficient, and charge) and the shape of the profile as it changes from WE to SE. The ion-exchange selectivity coefficient of the SE competing anion is important in establishing a sharp change in elution strength. A large difference in mobility between the WE and SE competing anions gives an SE with a higher final eluotropic strength, but the slope of the gradient is shallower. This results in a reduction in the efficiency of analyte focusing. To ensure maximum focusing efficiency, the WE and SE electrolytes should be selected such that the SE has the highest possible eluotropic strength for a given concentration of WE. The SE competing anion should also have a sufficiently low electrophoretic mobility to ensure focusing for the maximum number of analytes, and the mobility difference between the WE and SE competing anions should be as small as possible.
Collapse
|
23
|
Frit JS, Macka M. Solid-phase trapping of solutes for further chromatographic or electrophoretic analysis. J Chromatogr A 2000; 902:137-66. [PMID: 11192152 DOI: 10.1016/s0021-9673(00)00792-5] [Citation(s) in RCA: 65] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Because of its simplicity, speed and effectiveness, solid-phase extraction (SPE) has become the preferred technique for concentration of selected analytes prior to chromatographic or electrophoretic analysis. In this review the historical development of SPE is briefly traced. Then the principles of SPE are reviewed in some detail. Numerous references are given on the format, sorbents, elution conditions, online techniques and automation with special emphasis on relatively recent developments. The principles and recent advances in solid-phase microextraction (SPME) are also reviewed. The final section on selected recent applications includes an extensive list of references to work published within the last three years. Future trends and developments are discussed briefly.
Collapse
Affiliation(s)
- J S Frit
- Chemistry Department, Iowa State University, Ames 50011, USA.
| | | |
Collapse
|
24
|
Guzman NA. Determination of immunoreactive gonadotropin-releasing hormone in serum and urine by on-line immunoaffinity capillary electrophoresis coupled to mass spectrometry. JOURNAL OF CHROMATOGRAPHY. B, BIOMEDICAL SCIENCES AND APPLICATIONS 2000; 749:197-213. [PMID: 11145057 DOI: 10.1016/s0378-4347(00)00410-2] [Citation(s) in RCA: 68] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
The need for urgent diagnoses has propelled the development of automated analyses that can be performed in a short time at reasonable cost. One such method is immunoaffinity capillary electrophoresis. This emerging hybrid technology employs two powerful techniques coupled on-line for the direct and rapid determination of analytes present in biological fluids. The first technique, immunoaffinity, is used for the selective extraction of a molecule present in a complex matrix, utilizing a microscale-format chamber affinity device. An analyte (affinity target) present in serum or urine is captured by an immobilized molecular recognition antibody molecule (affinity ligand) bound to a solid support constituent (glass beads or an appropriate porous structure) of a microchamber affinity device. The second technique, capillary electrophoresis, is used for the high-resolution analytical separation of the purified and concentrated affinity target material after elution from the microchamber affinity device. In this work, immunoaffinity capillary electrophoresis was developed for the identification and characterization of a single constituent of a complex matrix. Immunoreactive gonadotropin-releasing hormone was determined in serum and urine specimens derived from a normal individual and from a patient suffering from benign prostatic hyperplasia. Furthermore, the on-line immuno-separation system was coupled in tandem to mass spectrometry to obtain molecular mass information of the affinity isolated and CE separated neuropeptide. This hybrid immuno-analytical technology is simple, rapid, selective and sensitive. In addition, an attempt was also made to characterize other urinary constituents by CE-MS that may lead to marker activity in the urine of the diseased subject. The hyphenation of analytical techniques has proved valuable in enhancing their individual features. The future of bioanalysis using miniaturized affinity systems is discussed in this paper.
Collapse
Affiliation(s)
- N A Guzman
- Bioanalytical Drug Metabolism, The R.W. Johnson Pharmaceutical Research Institute, Raritan, NJ 08896, USA.
| |
Collapse
|
25
|
Waterval JC, Hommels G, Teeuwsen J, Bult A, Lingeman H, Underberg WJ. Quantitative analysis of pharmaceutically active peptides using on-capillary analyte preconcentration transient isotachophoresis. Electrophoresis 2000; 21:2851-8. [PMID: 11001294 DOI: 10.1002/1522-2683(20000801)21:14<2851::aid-elps2851>3.0.co;2-q] [Citation(s) in RCA: 36] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
An on-capillary adsorptive phase in combination with capillary electrophoresis (CE), frequently referred to as preconcentration CE, for quantitative analysis of low peptide concentrations was developed. The capillary containing the on-line analyte preconcentrator can be constructed within 5 min from commercially available extraction disks. These disks contain poly(styrenedivinylbenzene) adsorbent particles incorporated in a matrix of inert Teflon, creating a mechanically stable sorbent. Therefore, no frits are needed in the capillary to hold the stationary phase in place. Several parameters, such as the required minimal elution volume, required elution strength, sample application speed or ionic strength, and the capacity were investigated and special interest was given to the quantitative properties of the method. Instead of nL injections, volumes up to a least 25 microL are possible, yielding improvements in detection limits of 3-4 orders of magnitude. The observed limit of detection for both model peptides was 20 pg, corresponding to a 20 microL injection of a 1 ng/mL solution of both model peptides. Using low-wavelength UV detection, reproducibility and linearity in the low nanogram range were satisfactory. No influence of matrix salt concentrations was observed, extending the use of CE to all kinds of samples.
Collapse
Affiliation(s)
- J C Waterval
- Universteit Utrecht, Faculty of Pharmacy, Department of Pharmaceutical Analysis, The Netherlands.
| | | | | | | | | | | |
Collapse
|
26
|
Abstract
AbstractAffinity chromatography is a type of liquid chromatography that makes use of biological-like interactions for the separation and specific analysis of sample components. This review describes the basic principles of affinity chromatography and examines its use in the testing of clinical samples, with an emphasis on HPLC-based methods. Some traditional applications of this approach include the use of boronate, lectin, protein A or protein G, and immunoaffinity supports for the direct quantification of solutes. Newer techniques that use antibody-based columns for on- or off-line sample extraction are examined in detail, as are methods that use affinity chromatography in combination with other analytical methods, such as reversed-phase liquid chromatography, gas chromatography, and capillary electrophoresis. Indirect analyte detection methods are also described in which immunoaffinity chromatography is used to perform flow-based immunoassays. Other applications that are reviewed include affinity-based chiral separations and the use of affinity chromatography for the study of drug or hormone interactions with binding proteins. Some areas of possible future developments are then considered, such as tandem affinity methods and the use of synthetic dyes, immobilized metal ions, molecular imprints, or aptamers as affinity ligands for clinical analytes.
Collapse
Affiliation(s)
- David S Hage
- Department of Chemistry, 738 Hamilton Hall, University of Nebraska, Lincoln, NE 68588-0304. Fax 402-472-9402; e-mail
| |
Collapse
|
27
|
Dalluge JJ, Sander LC. Precolumn affinity capillary electrophoresis for the identification of clinically relevant proteins in human serum: application to human cardiac troponin I. Anal Chem 1998; 70:5339-43. [PMID: 9868922 DOI: 10.1021/ac980773u] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
An approach has been developed to the on-line extraction and identification of clinical disease-state marker proteins in human serum. Fabrication of capillaries with integral packed beds for the online determination of human cardiac troponin I (cTnI), a diagnostic marker for myocardial infarction, at clinically relevant levels (2 nmol/L) in serum is demonstrated. The technique, termed precolumn affinity capillary electrophoresis (PA-CE), utilizes a short (approximately 5 mm) packed bed of porous silica containing covalently immobilized monoclonal anti-cTnI antibodies directly integrated within a separation capillary for the selective retention of cTnI from a complex matrix. Following a rinsing step to eliminate nonspecifically bound serum proteins and other impurities from the column, desorption of the antigen into the separation region of the PA-CE capillary for subsequent measurement of femto-molar amounts of cTnI by CE is effected by the injection of an appropriate elution buffer. Advantages of this approach over previously reported affinity preconcentration techniques, related applications for PA-CE technology, and its potential for use in the development of a certified reference material for cTnI in serum are discussed.
Collapse
Affiliation(s)
- J J Dalluge
- Analytical Chemistry Division, National Institute of Standards and Technology, Gaithersburg, Maryland 20899-0001, USA.
| | | |
Collapse
|
28
|
Heegaard NH, Nilsson S, Guzman NA. Affinity capillary electrophoresis: important application areas and some recent developments. JOURNAL OF CHROMATOGRAPHY. B, BIOMEDICAL SCIENCES AND APPLICATIONS 1998; 715:29-54. [PMID: 9792496 DOI: 10.1016/s0378-4347(98)00258-8] [Citation(s) in RCA: 156] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Affinity capillary electrophoresis (ACE) is a broad term referring to the separation by capillary electrophoresis of substances that participate in specific or non-specific affinity interactions during electrophoresis. The interacting molecules can be found free in solution or can be immobilized to a solid support. Every ACE mode has advantages and disadvantages. Each can be used for a wide variety of applications. This paper focuses on applications that include purification and concentration of analytes present in diluted solutions or complex matrices, quantitation of analytes based on calibration curves, and estimation of binding constants from direct and derived binding curves based on quantitation of analytes or on analyte migration shifts. A more recent chemicoaffinity strategy in capillary electrophoresis/capillary electrochromatography (CE/CEC) termed molecular imprinting ('plastic antibodies') is discussed as well. Although most ACE studies are aimed at characterizing small-molecular mass analytes such as drugs, hormones, and peptides, some efforts have been pursued to characterize larger biopolymers including proteins, such as immunoglobulins. Examples of affinity interactions that have been studied are antigen-antibody, hapten-antibody, lectin-sugar, drug-protein, and enzyme-substrate complexes using ultraviolet, laser-induced fluorescence, and mass spectrometer detectors. This paper also addresses the critical issue of background electrolyte selection and quantitation of analytes. Specific examples of bioaffinity applications are presented, and the future of ACE in the biomedical field is discussed.
Collapse
Affiliation(s)
- N H Heegaard
- Department of Autoimmunology, Statens Serum Institut, Copenhagen, Denmark
| | | | | |
Collapse
|
29
|
Hage DS. Survey of recent advances in analytical applications of immunoaffinity chromatography. JOURNAL OF CHROMATOGRAPHY. B, BIOMEDICAL SCIENCES AND APPLICATIONS 1998; 715:3-28. [PMID: 9792495 DOI: 10.1016/s0378-4347(97)00621-x] [Citation(s) in RCA: 134] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
Methods that use immunoaffinity chromatography (IAC) for sample preparation or detection are becoming increasingly popular as tools in the analysis of biological and nonbiological compounds. This paper presents an overview of immunoaffinity chromatography and examines some recent developments of this technique in analytical applications. The emphasis is placed on HPLC-based IAC methods or those that combine IAC with other instrumental techniques; however, novel approaches that employ low-performance IAC columns for chemical quantitation are also considered. Particular applications that are examined include (1) the use of IAC in the direct detection of analytes, (2) the extraction of samples by IAC prior to on- or off-line detection by other methods, (3) the use of IAC in chromatographic-based immunoassays, and (4) the development of postcolumn reactors based on IAC for the detection of analytes as they elute from other types of chromatographic columns. The advantages and limitations for each approach are considered. In addition, a summary is provided of reports in the literature that have used IAC for these various formats.
Collapse
Affiliation(s)
- D S Hage
- Department of Chemistry, University of Nebraska-Lincoln 68588-0304, USA
| |
Collapse
|
30
|
Affiliation(s)
- Stephen C. Beale
- Department of Chemistry, University of Alabama at Birmingham, 901 South 14th Street, CHEM 277, Birmingham, Alabama 36294
| |
Collapse
|
31
|
|
32
|
Knudsen CB, Beattie JH. On-line solid-phase extraction-capillary electrophoresis for enhanced detection sensitivity and selectivity: application to the analysis of metallothionein isoforms in sheep fetal liver. J Chromatogr A 1997; 792:463-73. [PMID: 9463913 DOI: 10.1016/s0021-9673(97)00857-1] [Citation(s) in RCA: 38] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
A simple and rapid capillary electrophoresis (CE) method for analysis of metallothionein (MT) isoforms is described. A modified two-step solvent extraction procedure was used in combination with CE and an on-line solid-phase preconcentration device for sensitive and reproducible detection of MT isoforms in sheep fetal liver. Preparation of twenty samples was practicable within a working day with subsequent automated overnight analysis by solid-phase extraction (SPE)-CE. A commercially available divinylbenzene-based reversed-phase resin was found to be most suitable for the SPE device because it is resistant to extremes of pH and can be adequately regenerated between analyses. Each SPE device was readily constructed from commonly available materials and was used for the reproducible separation of over 100 biological samples before replacement. Precision of analysis within or between sample batches was < 10% and usually < 5% while detection limits were at least 28 ng/ml for standards and 272 ng/ml for biological samples. This would indicate a detection limit of about 0.5 microgram/g wet weight of tissue. Recovery of MT from tissue cytosols by solvent extraction was measured using radiolabeled MT and was found to be just over 50% increasing to almost 70% by addition of NaCl to the homogenisation buffer. The combined solvent extraction and SPE-CE methodology was applied to the analysis of MT in sheep fetal liver and the results compared favorably with those obtained by high-resolution chromatography. MT-1 levels were 2 to 4-times higher than those of MT-2 and both isoforms decreased from day 89 to day 136 of gestation. These results were compared with MT levels in fetal liver from sheep embryos that had been perturbed by temporary transfer to an advanced uterine environment. Hepatic MT levels at day 136 of gestation were 3 to 8-times higher than in normal fetal liver and significant differences were observed with both isoforms.
Collapse
Affiliation(s)
- C B Knudsen
- Trace Element and Gene Expression Group, Rowett Research Institute, Bucksburn, Aberdeen, UK
| | | |
Collapse
|
33
|
Abstract
The application of affinity capillary electrophoresis (ACE) to the study of molecular interactions is reviewed. ACE appears to be a sensitive, versatile and convenient tool to obtain reliable data on binding constants and stoichiometries of interacting systems using the Hummel-Dreyer method and variants thereof. A powerful feature is the possibility to analyze simultaneously the affinity of a large number of compounds for the same ligand, making it a promising tool for the screening of large combinatorial libraries.
Collapse
Affiliation(s)
- G Rippel
- Delft University of Technology, Department of Biochemical Engineering, The Netherlands
| | | | | | | |
Collapse
|
34
|
Guzman NA, Park SS, Schaufelberger D, Hernandez L, Paez X, Rada P, Tomlinson AJ, Naylor S. New approaches in clinical chemistry: on-line analyte concentration and microreaction capillary electrophoresis for the determination of drugs, metabolic intermediates, and biopolymers in biological fluids. JOURNAL OF CHROMATOGRAPHY. B, BIOMEDICAL SCIENCES AND APPLICATIONS 1997; 697:37-66. [PMID: 9342656 DOI: 10.1016/s0378-4347(97)00275-2] [Citation(s) in RCA: 94] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
The use of capillary electrophoresis (CE) for clinically relevant assays is attractive since it often presents many advantages over contemporary methods. The small-diameter tubing that holds the separation medium has led to the development of multicapillary instruments, and simultaneous sample analysis. Furthermore, CE is compatible with a wide range of detectors, including UV-Vis, fluorescence, laser-induced fluorescence, electrochemistry, mass spectrometry, radiometric, and more recently nuclear magnetic resonance, and laser-induced circular dichroism systems. Selection of an appropriate detector can yield highly specific analyte detection with good mass sensitivity. Another attractive feature of CE is the low consumption of sample and reagents. However, it is paradoxical that this advantage also leads to severe limitation, namely poor concentration sensitivity. Often high analyte concentrations are required in order to have injection of sufficient material for detection. In this regard, a series of devices that are broadly termed 'analyte concentrators' have been developed for analyte preconcentration on-line with the CE capillary. These devices have been used primarily for non-specific analyte preconcentration using packing material of the C18 type. Alternatively, the use of very specific antibody-containing cartridges and enzyme-immobilized microreactors have been demonstrated. In the current report, we review the likely impact of the technology of capillary electrophoresis and the role of the CE analyte concentrator-microreactor on the analysis of biomolecules, present on complex matrices, in a clinical laboratory. Specific examples of the direct analysis of physiologically-derived fluids and microdialysates are presented, and a personal view of the future of CE in the clinical environment is given.
Collapse
Affiliation(s)
- N A Guzman
- R. W. Johnson Pharmaceutical Research Institute, Raritan, NJ 08869, USA
| | | | | | | | | | | | | | | |
Collapse
|
35
|
Anderson DJ, Guo B, Xu Y, Ng LM, Kricka LJ, Skogerboe KJ, Hage DS, Schoeff L, Wang J, Sokoll LJ, Chan DW, Ward KM, Davis KA. Clinical chemistry. Anal Chem 1997; 69:165R-229R. [PMID: 9195857 DOI: 10.1021/a1970008p] [Citation(s) in RCA: 53] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Affiliation(s)
- D J Anderson
- Department of Chemistry, Cleveland State University, Ohio 44115, USA
| | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
36
|
Zhang R, Hjertén S. A Micromethod for Concentration and Desalting Utilizing a Hollow Fiber, with Special Reference to Capillary Electrophoresis. Anal Chem 1997. [DOI: 10.1021/ac970141s] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
Affiliation(s)
- Rong Zhang
- Department of Biochemistry, Biomedical Center, Uppsala University, P.O. Box 576, S-751 23 Uppsala, Sweden
| | - Stellan Hjertén
- Department of Biochemistry, Biomedical Center, Uppsala University, P.O. Box 576, S-751 23 Uppsala, Sweden
| |
Collapse
|
37
|
Tomlinson AJ, Benson LM, Guzman NA, Naylor S. Preconcentration and microreaction technology on-line with capillary electrophoresis. J Chromatogr A 1996. [DOI: 10.1016/0021-9673(96)00332-9] [Citation(s) in RCA: 81] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|