1
|
Leenutaphong N, Phantumvanit P, Young AM, Panpisut P. Evaluation of setting kinetics, mechanical strength, ion release, and cytotoxicity of high-strength glass ionomer cement contained elastomeric micelles. BMC Oral Health 2024; 24:713. [PMID: 38902666 PMCID: PMC11191184 DOI: 10.1186/s12903-024-04468-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2024] [Accepted: 06/10/2024] [Indexed: 06/22/2024] Open
Abstract
BACKGROUND Low mechanical properties are the main limitation of glass ionomer cements (GICs). The incorporation of elastomeric micelles is expected to enhance the strength of GICs without detrimentally affecting their physical properties and biocompatibility. This study compared the chemical and mechanical properties, as well as the cytotoxicity, of elastomeric micelles-containing glass ionomer cement (DeltaFil, DT) with commonly used materials, including EQUIA Forte Fil (EF), Fuji IX GP Extra (F9), and Ketac Molar (KT). METHOD Powder particles of GICs were examined with SEM-EDX. Setting kinetics were assessed using ATR-FTIR. Biaxial flexural strength/modulus and Vickers surface microhardness were measured after immersion in water for 24 h and 4 weeks. The release of F, Al, Sr, and P in water over 8 weeks was analyzed using a fluoride-specific electrode and ICP-OES. The toxicity of the material extract on mouse fibroblasts was also evaluated. RESULTS High fluoride levels in the powder were detected with EF and F9. DT demonstrated an initial delay followed by a faster acid reaction compared to other cements, suggesting an improved snap set. DT also exhibited superior flexural strength than other materials at both 24 h and 4 weeks but lower surface microhardness (p < 0.05). EF and F9 showed higher release of F, Al, and P than DT and KT. There was no statistically significant difference in fibroblast viability among the tested materials (p > 0.05). CONCLUSIONS Elastomeric micelles-containing glass ionomer cement (DT) exhibited satisfactory mechanical properties and cytocompatibility compared with other materials. DT could, therefore, potentially be considered an alternative high-strength GIC for load-bearing restorations.
Collapse
Affiliation(s)
| | | | - Anne M Young
- Division of Biomaterials and Tissue Engineering, UCL Eastman Dental Institute, Royal Free Hospital, Rowland Hill Street, London, NW3 2PF, UK
| | - Piyaphong Panpisut
- Faculty of Dentistry, Thammasat University, Pathum Thani, 12120, Thailand.
- Thammasat University Research Unit in Dental and Bone Substitute Biomaterials, Thammasat University, Pathum Thani, 12120, Thailand.
| |
Collapse
|
2
|
Tan J, Hao J, Vann D, Pavelić K, Ozer F. Effect of Zeolite Incorporation on the Ion Release Properties of Silver-Reinforced Glass Ionomer Cement. Biomimetics (Basel) 2024; 9:365. [PMID: 38921245 PMCID: PMC11202068 DOI: 10.3390/biomimetics9060365] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2024] [Revised: 05/22/2024] [Accepted: 06/14/2024] [Indexed: 06/27/2024] Open
Abstract
BACKGROUND Zeolite can release antimicrobial silver ions in a targeted and controlled manner for an extended time, selectively inhibiting the growth of pathogenic oral bacteria when added to dental materials. The objective of this study was to investigate the effect of the addition of zeolite to silver-reinforced glass ionomer cement on the release of silver ions over time. METHODS Five concentrations of silver-zeolite (0%, 0.5%, 1%, 2%, 4% wt) were incorporated into silver-reinforced GIC in the form of 10 mm × 2 mm circular disks (n = 5). The disks were incubated in deionized water at 37 °C and ion release from the samples was measured at 1, 2, 7, and 30 days after immersion by inductively coupled atomic emission spectroscopy. RESULTS Incorporating silver-zeolite increased silver ion release from silver-reinforced GIC disks compared to the control disks (p < 0.05), while incorporating zeolite alone had no effect. Higher concentrations of added silver-zeolite resulted in increased silver ion release. Sustained silver ion release was observed for up to 30 days. CONCLUSION Adding silver-zeolite to silver-reinforced GIC may enhance its extended antibacterial effect in the oral cavity.
Collapse
Affiliation(s)
- Jessica Tan
- School of Dental Medicine, University of Pennsylvania, Philadelphia, PA 19104, USA; (J.T.); (J.H.)
| | - Jessica Hao
- School of Dental Medicine, University of Pennsylvania, Philadelphia, PA 19104, USA; (J.T.); (J.H.)
| | - David Vann
- School of Arts and Sciences, University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Krešimir Pavelić
- Faculty of Medicine, Juraj Dobrila University of Pula, 52100 Pula, Croatia;
| | - Fusun Ozer
- School of Dental Medicine, University of Pennsylvania, Philadelphia, PA 19104, USA; (J.T.); (J.H.)
| |
Collapse
|
3
|
Hegde D, Suprabha BS, Ginjupalli K, Suman E, Natarajan S, Shenoy R, Rao A. Addition of nisin to high-viscosity glass-ionomer cement: a comparative in vitro study on antibacterial and physical properties. Eur Arch Paediatr Dent 2024:10.1007/s40368-024-00910-w. [PMID: 38743212 DOI: 10.1007/s40368-024-00910-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2023] [Accepted: 04/18/2024] [Indexed: 05/16/2024]
Abstract
PURPOSE Nisin is a lantibiotic effective against Gram-positive microorganisms such as Streptococcus mutans. The study aimed to determine the effect of the addition of nisin to high-viscosity glass-ionomer cement (HVGIC) on its antibacterial activity, setting time, surface microhardness, and compressive strength. METHODS 1 and 3% w/w nisin were added to HVGIC before mixing. Unmodified HVGIC was the control. Agar disc diffusion, direct contact test, and scanning electron microscopy (SEM) analysis were used to evaluate antibacterial activity against S. mutans. Setting time, surface microhardness, and compressive strength were measured using Gilmore needle apparatus, digital microhardness tester, and universal testing machine, respectively. Statistical analysis included Student's t test, one-way ANOVA with Tamhane's post hoc test, and repeated-measures ANOVA. RESULTS As evidenced by the agar disc diffusion (p < 0.001), direct contact tests (p = 0.025), and SEM analysis of the S. mutans cell count and cell surface area (p = 0.049 and 0.003), 3% nisin had the strongest antibacterial activity. There was a dose-dependent increase in setting time (p = 0.005) and surface microhardness (p = 0.006), with no significant difference in compressive strength compared to control. CONCLUSION The addition of 3% nisin to HVGIC enhances the antibacterial action against S. mutans and surface microhardness without adversely affecting setting time and compressive strength.
Collapse
Affiliation(s)
- D Hegde
- Department of Pediatric and Preventive Dentistry, Manipal College of Dental Sciences Mangalore, Manipal Academy of Higher Education, Manipal, Karnataka, India
| | - B S Suprabha
- Department of Pediatric and Preventive Dentistry, Manipal College of Dental Sciences Mangalore, Manipal Academy of Higher Education, Manipal, Karnataka, India.
| | - K Ginjupalli
- Department of Dental Materials, Manipal College of Dental Sciences Manipal, Manipal Academy of Higher Education, Manipal, Karnataka, India
| | - E Suman
- Department of Microbiology, Kasturba Medical College Mangalore, Manipal Academy of Higher Education, Manipal, Karnataka, India
| | - S Natarajan
- Department of Oral Pathology and Microbiology, Manipal College of Dental Sciences Mangalore, Manipal Academy of Higher Education, Manipal, Karnataka, India
| | - R Shenoy
- Department of Public Health Dentistry, Manipal College of Dental Sciences Mangalore, Manipal Academy of Higher Education, Manipal, Karnataka, India
| | - A Rao
- Department of Pediatric and Preventive Dentistry, Manipal College of Dental Sciences Mangalore, Manipal Academy of Higher Education, Manipal, Karnataka, India
| |
Collapse
|
4
|
Alebady MH, Hamama HH, Mahmoud SH. Effect of various surface coating methods on surface roughness, micromorphological analysis and fluoride release from contemporary glass ionomer restorations. BMC Oral Health 2024; 24:504. [PMID: 38685036 PMCID: PMC11057179 DOI: 10.1186/s12903-024-04234-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2023] [Accepted: 04/08/2024] [Indexed: 05/02/2024] Open
Abstract
OBJECTIVE To evaluate the effect of various surface coating methods on surface roughness, micromorphological analysis and fluoride release from contemporary resin-modified and conventional glass ionomer restorations. MATERIALS & METHODS A total of 72 permanent human molars were used in this study. The teeth were randomly assigned into 2 groups according to type of restorative materials used; resin modified glass ionomer cement and conventional glass ionomer (SDI Limited. Bayswater Victoria, Australia). Each group was subdivided into 3 subgroups according to the application of coat material; Sub-group1: without application of coat; Sub-group2: manufacturer recommended coat was applied and sub-group3: customized (vaseline) coat was applied. Each group was then subdivided into two divisions according to the time of testing; immediate (after 24 h) and delayed (after 6 months of storage). Three specimens from each sub-group were selected for surface roughness test (AFM) and another 3 specimens for the micromorphological analysis using scanning electron microscope (SEM). For the fluoride release test, a total of 60 cylindrical discs were used (n = 60). The discs were randomly split into 2 groups according to type of restorative materials used (n = 30); resin modified glass ionomer cement and conventional glass ionomer. Each group was subdivided into 3 subgroups (n = 10) according to the application of the coat material; Sub-group1: without application of coat; Sub-group2: with the manufacturer recommended coat and sub-group3: with application of customized (vaseline) coat. Data for each test was then collected, tabulated, were collected, tabulated, and tested for the normality with Shapiro-Wilk test. Based on the outcome of normality test, the significant effects of variables were assessed using appropriate statistical analysis testing methods. RESULTS Regarding the data obtained from surface roughness test, Shapiro-Wilk test showed normal distribution pattern of all values (p > 0.05). Accordingly, Two-way ANOVA outcome showed that the 'type of restoration' or 'test time' had statistically significant effect on the AFM test (p < 0.05). Regarding Fluoride specific ion electrode test 2-way ANOVA followed by Least Significant Difference (LSD) Post-hoc test revealed significant difference among the groups (p < 0.05). It showed that SDI GIC group after 14 days of measurement had the highest mean of fluoride release (36.38 ± 3.16 PPM) and SDI RMGIC after 30 days of measurement had the second highest mean of fluoride release (43.28 ± 1.89 PPM). Finally, regarding the micromorphological analysis using SEM, a slight difference was observed between the studied groups. CONCLUSIONS Based on the results of this study, various coatings enhance surface roughness in the initial 24 h of restoration insertion. Different coat types seems that have no influence on fluoride release and the micromorphological features of the restoration/dentin interface.
Collapse
Affiliation(s)
- Mohanad H Alebady
- Conservative Dentistry Department, Faculty of Dentistry, Mansoura University, Mansoura, 35516, Egypt
| | - Hamdi H Hamama
- Conservative Dentistry Department, Faculty of Dentistry, Mansoura University, Mansoura, 35516, Egypt.
| | - Salah H Mahmoud
- Conservative Dentistry Department, Faculty of Dentistry, Mansoura University, Mansoura, 35516, Egypt
| |
Collapse
|
5
|
Celik ZC, Elbek Cubukcu C, Celik H. Surface characteristics and wettability of novel gingival col designed 3-D printed dental sectional matrices. BIOMED ENG-BIOMED TE 2024; 69:11-15. [PMID: 37497750 DOI: 10.1515/bmt-2023-0229] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2023] [Accepted: 06/30/2023] [Indexed: 07/28/2023]
Abstract
OBJECTIVE The physical properties and wettability of 3-D printed Polyethylene terephthalate - glycol (PET-G) and Poly(lactic) acid (PLA) dental sectional matrices were investigated. METHODS Experimental matrices was designed in a rectangular shape one-side depression corresponds to gingival col and without sharp edges and printed on FDM machine Ender Pro 3 (Creality®, Shenzhen, China). The physical textures, thicknesses, water contact angles were compared to conventional stainless steel (SS) matrix. RESULTS PETG and PLA sample matrices were clinically single-side smooth compared to SS matrix. PETG specimens had uniformly 0.055 mm whereas PLAs were non-uniformly ∼0.065-0.075 mm in thickness. The mean ± standard deviation (SS) of contact angle for SS was 78.29 ± 0.18, for PETG was 72.09 ± 0.94, for PLA was 73.03 ± 1.17. CONCLUSION PETG and PLA dental matrices might have desirable properties: being hydrophobic, non-charged, easy to manufacture and mimicking the gingival col depression in the dental interproximal contact area.
Collapse
Affiliation(s)
- Zeynep Ceren Celik
- Department of Restorative Dentistry, Faculty of Dentistry, Bursa Uludag University, Bursa, Türkiye
| | - Cigdem Elbek Cubukcu
- Department of Pedodontics, Faculty of Dentistry, Bursa Uludag University, Bursa, Türkiye
| | - Halil Celik
- Department of Periodontology, Faculty of Dentistry, Istinye University, Istanbul, Türkiye
| |
Collapse
|
6
|
Sivavong P, Sanprasert C, Leekhaphan P, Chooboonlarp S, Bunsong C, Pianmee C, Poolkerd P, Singthong T, Gorwong P, Nantanapiboon D. Effect of ionizing radiation on the mechanical properties of current fluoride-releasing materials. BDJ Open 2024; 10:10. [PMID: 38374259 PMCID: PMC10876543 DOI: 10.1038/s41405-024-00192-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2023] [Revised: 01/12/2024] [Accepted: 01/17/2024] [Indexed: 02/21/2024] Open
Abstract
OBJECTIVES This study aimed to evaluate the effect of fractional radiation on the mechanical properties of fluoride-releasing materials. MATERIALS AND METHODS High-viscosity glass ionomer cement (F9), resin-modified glass ionomer cement (F2), glass hybrid restoration (EQ), and bioactive composite (AC) were divided into 3 subgroups: 0, 35, and 70 Gy fractional radiation doses. The specimens were subjected to surface roughness, Vickers microhardness, and compressive strength tests. The chemical components and morphology of the tested specimens were observed via energy dispersive spectroscopy and scanning electron microscopy. The data were analyzed using two-way ANOVA with Bonferroni post hoc analysis. RESULTS After exposure to fractional radiation, the surface roughness increased in all the groups. F9 had the highest surface roughness, while AC had the lowest surface roughness within the same radiation dose. The Vickers microhardness decreased in F9 and EQ. The AC had the highest compressive strength among all the groups, followed by F2. More cracks and voids were inspected, and no substantial differences in the chemical components were observed. CONCLUSIONS After fractional radiation, the surface roughness of all fluoride-releasing materials increased, while the Vickers microhardness of F9 and EQ decreased. However, the compressive strength increased only in F2 and AC.
Collapse
Affiliation(s)
- Pimduean Sivavong
- Department of Operative Dentistry, Faculty of Dentistry, Chulalongkorn University, Bangkok, 10330, Thailand
| | | | | | | | - Chalermchart Bunsong
- Department of Radiation Therapy, Chonburi Cancer Hospital, Chonburi, 20000, Thailand
| | | | - Potsawat Poolkerd
- Dental Department, Panyananthaphikkhu Chonprathan Medical Center, Srinakharinwirot University, Nonthaburi, 11120, Thailand
| | - Thawanrat Singthong
- Dental Material Research and Development Center, Faculty of Dentistry, Chulalongkorn University, Bangkok, 10330, Thailand
| | - Puliwan Gorwong
- Dental Material Research and Development Center, Faculty of Dentistry, Chulalongkorn University, Bangkok, 10330, Thailand
| | - Dusit Nantanapiboon
- Department of Operative Dentistry, Faculty of Dentistry, Chulalongkorn University, Bangkok, 10330, Thailand.
- Dental Material Research and Development Center, Faculty of Dentistry, Chulalongkorn University, Bangkok, 10330, Thailand.
| |
Collapse
|
7
|
Durrant L, Mutahar M, Daghrery AA, Albar NH, Alwadai GS, Alqahtani SA, Al Dehailan LA, Abogazalah NN, Alamoudi NA, Al Moaleem MM. Clinical Performance of Glass Ionomer Cement in Load-Bearing Restorations: A Systematic Review. Med Sci Monit 2024; 30:e943489. [PMID: 38351604 PMCID: PMC10878495 DOI: 10.12659/msm.943489] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2023] [Accepted: 01/17/2024] [Indexed: 02/16/2024] Open
Abstract
Glass ionomer cement (GIC) is a self-adhesive dental restorative material composed of a polyacrylic acid liquid and fluoro-aluminosilicate glass powder. It is commonly used for cementation during dental restoration. This study aimed to systematically review the existing literature regarding the clinical performance of GIC in load-bearing dental restorations. A comprehensive literature search was conducted in EBSCO, PubMed, Embrace, and Cochrane databases. Only randomized controlled trials (RCTs) were included in the search, and a broad search technique was used, where inclusion and exclusion criteria were applied. After a thorough evaluation, 12 RCTs were extensively reviewed, and whether GIC is suitable for load-bearing restorations was determined. Significant variations in staining surface or margin, color match, translucency, esthetic anatomical form, retention, material fracture, marginal adaptation, surface luster, occlusal contour, wear, and approximal anatomical form indicated the unsuitability of GIC. By contrast, significance differences in patient view and periodontal response indicated that GIC is suitable. No significant differences in postoperative sensitivity, recurrence of caries, or tooth integrity were observed. Nevertheless, the results of the review demonstrated that the clinical performance of GIC is comparable to that of traditional restorative materials with regard to the parameters analyzed. GIC is a suitable restorative material for load-bearing restorations regarding surface margin, esthetic anatomical form, material retention and fracture, marginal adaptation, occlusal contour, wear, and approximal anatomical form. It reduces other parameters, such as postoperative sensitivity, recurrence of caries, and tooth integrity.
Collapse
Affiliation(s)
- Laura Durrant
- Dental Academy, University of Portsmouth, Portsmouth, UK
| | - Mahdi Mutahar
- Dental Academy, University of Portsmouth, Portsmouth, UK
| | - Arwa A. Daghrery
- Department of Restorative Dental Sciences, College of Dentistry, Jazan University, Jazan, Saudi Arabia
| | - Nassreen H. Albar
- Department of Restorative Dental Sciences, College of Dentistry, Jazan University, Jazan, Saudi Arabia
| | - Ghadeer Saleh Alwadai
- Department of Restorative Dental Science, College of Dentistry, King Khalid University, Abha, Saudi Arabia
| | - Saleh Ali Alqahtani
- Department of Restorative Dental Science, College of Dentistry, King Khalid University, Abha, Saudi Arabia
| | - Laila Adel Al Dehailan
- Department of Restorative Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Naif Nabel Abogazalah
- Department of Restorative Dental Science, College of Dentistry, King Khalid University, Abha, Saudi Arabia
| | - Nada Ahmad Alamoudi
- Department of Restorative Dental Science, College of Dentistry, King Khalid University, Abha, Saudi Arabia
| | - Mohammed M. Al Moaleem
- Department of Prosthetic Dental Science, College of Dentistry, Jazan University, Jazan, Saudi Arabia
| |
Collapse
|
8
|
Kantovitz KR, Carlos NR, Silva IAPS, Braido C, Costa BC, Kitagawa IL, Nociti-Jr FH, Basting RT, de Figueiredo FKP, Lisboa-Filho PN. TiO 2 nanotube-based nanotechnology applied to high-viscosity conventional glass-ionomer cement: ultrastructural analyses and physicochemical characterization. Odontology 2023; 111:916-928. [PMID: 36917400 DOI: 10.1007/s10266-023-00799-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2022] [Accepted: 02/28/2023] [Indexed: 03/16/2023]
Abstract
This study characterized TiO2 nanotube (TiO2-nt) ultrastructure and morphology, and the physicochemical impact on high-viscosity conventional glass-ionomer cement (GIC). TiO2-nt was synthesized by the alkaline method (n = 3), assessed by scanning (SEM) and transmission electron microscope (TEM), and was added (3%, 5%, 7%-in weight) to KM (Ketac Molar EasyMix™). Analyses included: SEM; Energy-dispersive spectroscopy (EDS); Raman spectroscopy (RAMAN); Setting time with Gillmore needles (ST); Color (Co); Radiopacity (XR); Water sorption (WS); and solubility (SO). Quantitative data were submitted to ANOVA and Tukey's tests (chr = 0.05). External and internal TiO2-nt diameters were 11 ± 2 nm and 6 ± 0 nm, respectively. Data analyses showed: (i) TiO2-nt present into KM matrix, with a concentration-dependent increase of Ti levels into KM, (ii) physical interaction between KM and TiO2-nt, (iii) longer initial ST for the 7% group compared to KM and 3% groups (p ≤ 0.01), (iv) decreased luminosity and yellowness for the 5% and 7% groups, (v) 36% greater radiopacity for the 5% group compared to enamel, dentin, and KM, and (vi) lower SO values for the 5% group, with no significant differences on WS across the groups. TiO2-nt displayed physical interaction with KM matrix, and also modified SO, XR and Co, without affecting ST. This study provides information on the potential impact of TiO2-nt on GIC performance. TiO2-nt may be proposed to boost confidence among dental surgeons in terms of GIC's handling characteristics, success rate and differential diagnostic.
Collapse
Affiliation(s)
| | - Natália Russo Carlos
- Faculdade São Leopoldo, SLMANDIC, Rua José Rocha Junqueira, 13, Campinas, SP, 13045-755, Brazil
| | | | - Caroline Braido
- Pediatric Division, Department of Health Sciences, Orthodontics and Pediatric Dentistry, Piracicaba Dental School, University of Campinas, UNICAMP, Piracicaba, SP, Brazil
| | - Bruna Carolina Costa
- Department of Physics, School of Science, São Paulo State University, UNESP, Bauru, SP, Brazil
| | - Igor Lebedenco Kitagawa
- Federal Institute of Education, Science and Technology of São Paulo, IFSP, Birigui, SP, Brazil
| | - Francisco Humberto Nociti-Jr
- Faculdade São Leopoldo, SLMANDIC, Rua José Rocha Junqueira, 13, Campinas, SP, 13045-755, Brazil
- Division of Periodontics, Department of Prosthodontics and Periodontics, Piracicaba Dental School, University of Campinas, UNICAMP, Piracicaba, SP, Brazil
| | - Roberta Tarkany Basting
- Faculdade São Leopoldo, SLMANDIC, Rua José Rocha Junqueira, 13, Campinas, SP, 13045-755, Brazil
| | | | | |
Collapse
|
9
|
Costăchel BC, Bechir A, Burcea A, Mihai LL, Ionescu T, Marcu OA, Bechir ES. Evaluation of Abfraction Lesions Restored with Three Dental Materials: A Comparative Study. Clin Pract 2023; 13:1043-1058. [PMID: 37736929 PMCID: PMC10514784 DOI: 10.3390/clinpract13050093] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2023] [Revised: 08/18/2023] [Accepted: 08/23/2023] [Indexed: 09/23/2023] Open
Abstract
BACKGROUND Abfraction lesions are manifested as damage to hard tissues in the cervical area of dental crowns. The study aimed to assess the direct restoration of abfraction lesions according to the modified United States Public Health Service (USPHS) criteria for 24 months. The restorations were accomplished with Fuji Bulk-GC, Omnichroma Flow-Tokuyama, and Beautifil® II-Shofu dental materials, and the therapy was or was not associated with wearing thermoformed mouthguards. METHODS From the 53 selected and analyzed patients (n = 53), 28 patients (with restorations of abfraction lesions) belonged to the 1st group and 25 patients (with 105 restorations, who also wore mouthguards) belonged to the 2nd group. Blind determination assessments were effectuated at baseline and after 2, 6, 12, 18, and 24 months. Results showed that, regardless of the rating score, there are no significant statistical differences in the evaluation criteria between the two groups of patients Conclusions: For each material, the scores of USPHS criterion presented good clinical performances after 24 months, with no significant statistical differences between the fillings and the applied therapy in the two groups of patients.
Collapse
Affiliation(s)
- Bogdan Constantin Costăchel
- Doctoral School in Dental Medicine, “Titu Maiorescu” University of Bucharest, 189 Calea Văcăreşti, 040056 Bucharest, Romania;
| | - Anamaria Bechir
- Faculty of Dental Medicine, “Titu Maiorescu” University of Bucharest, 67A Gh. Petrascu Street, 031592 Bucharest, Romania; (L.L.M.); (T.I.)
| | - Alexandru Burcea
- Faculty of Dental Medicine, “Titu Maiorescu” University of Bucharest, 67A Gh. Petrascu Street, 031592 Bucharest, Romania; (L.L.M.); (T.I.)
| | - Laurența Lelia Mihai
- Faculty of Dental Medicine, “Titu Maiorescu” University of Bucharest, 67A Gh. Petrascu Street, 031592 Bucharest, Romania; (L.L.M.); (T.I.)
| | - Tudor Ionescu
- Faculty of Dental Medicine, “Titu Maiorescu” University of Bucharest, 67A Gh. Petrascu Street, 031592 Bucharest, Romania; (L.L.M.); (T.I.)
| | - Olivia Andreea Marcu
- Faculty of Medicine and Pharmacy, University of Oradea, 10 P-ta 1 Decembrie, 410073 Oradea, Romania;
| | - Edwin Sever Bechir
- Faculty of Dental Medicine, “George Emil Palade” University of Medicine, Pharmacy, Science and Technology of Targu Mures, 38 Gh. Marinescu Street, 540142 Targu Mures, Romania;
| |
Collapse
|
10
|
Potiprapanpong W, Naruphontjirakul P, Khamsuk C, Channasanon S, Toneluck A, Tanodekaew S, Monmaturapoj N, Young AM, Panpisut P. Assessment of Mechanical/Chemical Properties and Cytotoxicity of Resin-Modified Glass Ionomer Cements Containing Sr/F-Bioactive Glass Nanoparticles and Methacrylate Functionalized Polyacids. Int J Mol Sci 2023; 24:10231. [PMID: 37373383 DOI: 10.3390/ijms241210231] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2023] [Revised: 06/12/2023] [Accepted: 06/13/2023] [Indexed: 06/29/2023] Open
Abstract
This study prepared low-toxicity, elemental-releasing resin-modified glass ionomer cements (RMGICs). The effect of 2-hydroxyethyl methacrylate (HEMA, 0 or 5 wt%) and Sr/F-bioactive glass nanoparticles (Sr/F-BGNPs, 5 or 10 wt%) on chemical/mechanical properties and cytotoxicity were examined. Commercial RMGIC (Vitrebond, VB) and calcium silicate cement (Theracal LC, TC) were used as comparisons. Adding HEMA and increasing Sr/F-BGNPs concentration decreased monomer conversion and enhanced elemental release but without significant effect on cytotoxicity. Rising Sr/F-BGNPs reduced the strength of the materials. The degree of monomer conversion of VB (96%) was much higher than that of the experimental RMGICs (21-51%) and TC (28%). The highest biaxial flexural strength of experimental materials (31 MPa) was significantly lower than VB (46 MPa) (p < 0.01) but higher than TC (24 MPa). The RMGICs with 5 wt% HEMA showed higher cumulative fluoride release (137 ppm) than VB (88 ppm) (p < 0.01). Unlike VB, all experimental RMGICs showed Ca, P, and Sr release. Cell viability in the presence of extracts from experimental RMGICs (89-98%) and TC (93%) was significantly higher than for VB (4%). Experimental RMGICs showed desirable physical/mechanical properties with lower toxicity than the commercial material.
Collapse
Affiliation(s)
| | - Parichart Naruphontjirakul
- Biological Engineering Program, Faculty of Engineering, King Mongkut's University of Technology Thonburi, 126 Pracha Uthit Rd., Bang Mod, Thung Khru, Bangkok 10140, Thailand
| | - Chutikarn Khamsuk
- Assistive Technology and Medical Devices Research Center (A-MED), National Science and Technology Development Agency, Pathum Thani 12120, Thailand
| | - Somruethai Channasanon
- National Metal and Materials Technology Center (MTEC), National Science and Technology Development Agency, Pathum Thani 12120, Thailand
| | - Arnit Toneluck
- Faculty of Dentistry, Thammasat University, Pathum Thani 12120, Thailand
| | - Siriporn Tanodekaew
- National Metal and Materials Technology Center (MTEC), National Science and Technology Development Agency, Pathum Thani 12120, Thailand
| | - Naruporn Monmaturapoj
- Assistive Technology and Medical Devices Research Center (A-MED), National Science and Technology Development Agency, Pathum Thani 12120, Thailand
| | - Anne M Young
- Division of Biomaterials and Tissue Engineering, UCL Eastman Dental Institute, Royal Free Hospital, Rowland Hill Street, London NW3 2PF, UK
| | - Piyaphong Panpisut
- Faculty of Dentistry, Thammasat University, Pathum Thani 12120, Thailand
- Thammasat University Research Unit in Dental and Bone Substitute Biomaterials, Thammasat University, Pathum Thani 12120, Thailand
| |
Collapse
|
11
|
Łępicka M, Niewczas AM, Rodziewicz MU, Pikuła K, Kordos P, Gredes T, Kurzydłowski KJ. The influence of hydrothermal fatigue on the clinically relevant functional properties of conventional glass-ionomer cements. Sci Rep 2023; 13:8738. [PMID: 37253971 DOI: 10.1038/s41598-023-35880-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2023] [Accepted: 05/25/2023] [Indexed: 06/01/2023] Open
Abstract
During their everyday service, the restorative dental materials are subjected to temperature changes which can be viewed as intensive in the context of the highest allowed temperatures for these materials. In this work, the effect of hydrothermal fatigue on the in vitro tribological performance, compression strength, microhardness, and surface roughness of glass-ionomer cements was studied. Samples of 3 commercially available cements were divided into the reference (aged 14 days) and thermocycled (20,000 cycles; 5-55 °C) groups. The results obtained show that functional properties of the specimens subjected to thermal fatigue significantly differ from the literature data on the cements aged at constant temperatures. The effect of hydrothermal fatigue on the functional properties of cements is discussed in the context of processes induced by exposure to variable temperatures.
Collapse
Affiliation(s)
- Magdalena Łępicka
- Faculty of Mechanical Engineering, Institute of Mechanical Engineering, Bialystok University of Technology, Wiejska 45C St., 15-352, Bialystok, Poland.
| | - Agata Maria Niewczas
- Department of Conservative Dentistry with Endodontics, Medical University of Lublin, W. Chodzki 6, 20-093, Lublin, Poland
| | - Magdalena Urszula Rodziewicz
- Faculty of Mechanical Engineering, Institute of Mechanical Engineering, Bialystok University of Technology, Wiejska 45C St., 15-352, Bialystok, Poland
| | - Konrad Pikuła
- Department of Conservative Dentistry with Endodontics, Medical University of Lublin, W. Chodzki 6, 20-093, Lublin, Poland
| | - Paweł Kordos
- Institute of Transport, Combustion Engines and Ecology, Lublin University of Technology, Nadbystrzycka 36, 20-618, Lublin, Poland
| | - Tomasz Gredes
- Department of Orthodontics, Technische Universität Dresden, Carl Gustav Carus Campus, Fetscherstr. 74, 01307, Dresden, Germany
- Department of Orthodontics and Temporomandibular Disorders, Poznan University of Medical Sciences, Bukowska 70, 60-812, Poznan, Poland
| | - Krzysztof Jan Kurzydłowski
- Faculty of Mechanical Engineering, Institute of Mechanical Engineering, Bialystok University of Technology, Wiejska 45C St., 15-352, Bialystok, Poland
| |
Collapse
|
12
|
Magalhães GDAP, Thomson JJ, Smoczer C, Young LA, Matos AO, Pacheco RR, Souza MT, Zanotto ED, Puppin Rontani RM. Effect of Biosilicate ® Addition on Physical-Mechanical and Biological Properties of Dental Glass Ionomer Cements. J Funct Biomater 2023; 14:302. [PMID: 37367266 DOI: 10.3390/jfb14060302] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2023] [Revised: 05/26/2023] [Accepted: 05/27/2023] [Indexed: 06/28/2023] Open
Abstract
This study investigated the influence of incorporating Biosilicate® on the physico-mechanical and biological properties of glass ionomer cement (GIC). This bioactive glass ceramic (23.75% Na2O, 23.75% CaO, 48.5% SiO2, and 4% P2O5) was incorporated by weight (5%, 10%, or 15%) into commercially available GICs (Maxxion R and Fuji IX GP). Surface characterization was made by SEM (n = 3), EDS (n = 3), and FTIR (n = 1). The setting and working (S/W time) times (n = 3) and compressive strength (CS) were analyzed (n = 10) according to ISO 9917-1:2007. The ion release (n = 6) was determined and quantified by ICP OES and by UV-Vis for Ca, Na, Al, Si, P, and F. To verify cell cytotoxicity, stem cells from the apical papilla (SCAP) were exposed to eluates (n = 3, at a ratio of 1.8 cm2/mL) and analyzed 24 h post-exposure. Antimicrobial activity against Streptococcus mutans (ATCC 25175, NCTC 10449) was analyzed by direct contact for 2 h (n = 5). The data were submitted for normality and lognormality testing. One-way ANOVA and Tukey's test were applied for the working and setting time, compressive strength, and ion release data. Data from cytotoxicity and antimicrobial activity were submitted for Kruskal-Wallis' testing and Dunn's post hoc test (α = 0.05). Among all experimental groups, only those with 5% (wt) of Biosilicate® showed better surface quality. Only M5% showed a comparable W/S time to the original material (p = 0.7254 and p = 0.5912). CS was maintained for all Maxxion R groups (p > 0.0001) and declined for Fuji IX experimental groups (p < 0.0001). The Na, Si, P, and F ions released were significantly increased for all Maxxion R and Fuji IX groups (p < 0.0001). Cytotoxicity was increased only for Maxxion R with 5% and 10% of Biosilicate®. A higher inhibition of S. mutans growth was observed for Maxxion R with 5% of Biosilicate® (less than 100 CFU/mL), followed by Maxxion R with 10% of Biosilicate® (p = 0.0053) and Maxxion R without the glass ceramic (p = 0.0093). Maxxion R and Fuji IX presented different behaviors regarding Biosilicate® incorporation. The impacts on physico-mechanical and biological properties were different depending on the GIC, but therapeutic ion release was increased for both materials.
Collapse
Affiliation(s)
- Gabriela de Alencar Pinto Magalhães
- Department of Health Sciences and Pediatric Dentistry, Pediatric Division, Piracicaba Dental School, UNICAMP, State University of Campinas, Piracicaba 13414-903, Brazil
| | - Joshua J Thomson
- Division of Integrated Biomedical Sciences, University of Detroit Mercy School of Dentistry, Detroit, MI 48208, USA
| | - Cristine Smoczer
- Division of Integrated Biomedical Sciences, University of Detroit Mercy School of Dentistry, Detroit, MI 48208, USA
| | - Laura Ann Young
- Division of Integrated Biomedical Sciences, University of Detroit Mercy School of Dentistry, Detroit, MI 48208, USA
| | - Adaias O Matos
- Division of Clinical Essentials and Simulation, University of Detroit Mercy School of Dentistry, Detroit, MI 48208, USA
| | - Rafael Rocha Pacheco
- Department of Restorative Sciences, Dental College of Georgia at Augusta University, Augusta, GA 30912, USA
| | - Maria Trevelin Souza
- Vitreous Materials Laboratory, Department of Materials Engineering, Center for Research, Education and Technology in Vitreous Materials (CeRTEV), Federal University of São Carlos (UFSCar), São Carlos 13565-905, Brazil
| | - Edgar Dutra Zanotto
- Vitreous Materials Laboratory, Department of Materials Engineering, Center for Research, Education and Technology in Vitreous Materials (CeRTEV), Federal University of São Carlos (UFSCar), São Carlos 13565-905, Brazil
| | - Regina Maria Puppin Rontani
- Department of Health Sciences and Pediatric Dentistry, Pediatric Division, Piracicaba Dental School, UNICAMP, State University of Campinas, Piracicaba 13414-903, Brazil
| |
Collapse
|
13
|
Ge KX, Lung CYK, Lam WYH, Chu CH, Yu OY. A novel glass ionomer cement with silver zeolite for restorative dentistry. J Dent 2023; 133:104524. [PMID: 37080532 DOI: 10.1016/j.jdent.2023.104524] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2023] [Revised: 04/15/2023] [Accepted: 04/17/2023] [Indexed: 04/22/2023] Open
Abstract
OBJECTIVE To develop an antimicrobial silver zeolite glass ionomer cement (SZ-GIC) and determine its biocompatibility, physical, adhesive and antibacterial properties. METHODS Silver nitrate and sodium zeolite were used to synthesize silver zeolite (SZ). SZ-GICs were prepared by incorporating SZ into GIC at 5% (SZ-GIC5), 2% (SZ-GIC2), or 1% (SZ-GIC1) by weight, respectively. The SZ-GICs were characterized by evaluating surface morphology, topography and elemental composition. SZ-GICs' biocompatibility was assessed by evaluating cell cytotoxicity. Their physical properties were determined by testing setting time, compressive strength, flexural strength, water sorption and solubility. Their adhesive property was assessed by evaluating micro-tensile bond strength. Their antibacterial properties were assessed by evaluating biofilm growth kinetic, metabolic activity, viability and morphology. GIC was used as a control. RESULTS SZ was a three-dimensional crystalline mineral. SZ-GICs (including SZ-GIC 5, 2 and 1) showed similar surface morphology and topography to GIC. SZ-GIC1 and GIC had no difference in cell cytotoxicity (p>0.05). SZ-GICs and GIC showed no difference in setting time (p>0.05). SZ-GICs had higher compressive and flexural strength than GIC (p<0.05). SZ-GIC2 and SZ-GIC1 showed lower water sorption and solubility than GIC (p<0.05). SZ-GICs had higher micro-tensile bond strength than GIC (p<0.05). Biofilms on SZ-GICs' surfaces showed lower colony-forming units, decreased metabolic activities, higher percentages of dead cells and more ruptured bacterial cells compared with those on GIC. CONCLUSION SZ-GIC with silver zeolite at 1% by weight are as biocompatible as conventional GIC. The SZ-GICs have enhanced physical, adhesive and antibacterial properties than GIC. CLINICAL SIGNIFICANCE A silver zeolite glass ionomer cement was developed. The SZ-GICs have great potential for caries prevention and management.
Collapse
Affiliation(s)
- Kelsey Xingyun Ge
- Faculty of Dentistry, The University of Hong Kong, Hong Kong, S.A.R., China
| | | | - Walter Yu-Hang Lam
- Faculty of Dentistry, The University of Hong Kong, Hong Kong, S.A.R., China
| | - Chun-Hung Chu
- Faculty of Dentistry, The University of Hong Kong, Hong Kong, S.A.R., China
| | - Ollie Yiru Yu
- Faculty of Dentistry, The University of Hong Kong, Hong Kong, S.A.R., China.
| |
Collapse
|
14
|
Arafa SK, Sherief DI, Nassif MS. Effect of aging on mechanical and antibacterial properties of fluorinated graphene reinforced glass ionomer: In vitro study. J Mech Behav Biomed Mater 2023; 142:105803. [PMID: 37031564 DOI: 10.1016/j.jmbbm.2023.105803] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2023] [Revised: 03/20/2023] [Accepted: 03/23/2023] [Indexed: 04/08/2023]
Abstract
OBJECTIVES This study: 1) aims to test the mechanical and antibacterial properties of fluorinated graphene strengthened glass ionomer materials (FG/GICs); 2) aims to investigate the effects of thermo-cycling on (FG/GICs). MATERIALS AND METHODS Fluorinated graphene (FG) with bright white color was prepared from fluorinated graphite (SIGMA Aldrich), using modified Hummer's method, to be added to conventional glass ionomer cements (GICs). In addition to a control group (group 1), experimentally modified GICs were prepared by adding FG to the conventional glass ionomer powder with three different weight ratios; (group 2, 1 wt %; group 3, 2.5 wt %; and group 4, 5 wt %) using mechanical blending method. Experimental groups of the specimens (n = 240) were divided, for each concentration (n = 120) half of the specimens were subjected to thermo-cycling. Hardness, compressive strength, and antibacterial activity of (FG/GICs) were measured with and without thermo-cycling. Compressive strength was measured by a universal testing machine, hardness was measured using a Vickers micro-hardness tester, and antibacterial effects against staphylococcus aureus and streptococcus mutans were tested by the pellicle sticking method. For statistical analysis, numerical data were explored for normality and variance homogeneity using Shapiro-Wilk and Leven's tests respectively. RESULTS The prepared (FG/GICs) showed an increase in hardness in group 4 (p < 0.001). Groups 3 and 4 gave the highest compressive strength values with no significant difference between them (p < 0.001). Groups 2, 3, and 4 showed improved antibacterial activity with no statistical difference between them (p > 0.001). Results after thermo-cycling showed significantly decreased hardness, and compressive strength values (p < 0.001), however, the results of antibacterial activity against streptococcus mutans showed no statistical difference after thermo-cycling (group 2, p = 0.05; group 3, p = 0.18; group 4, p = 0.26). The same results were observed for antibacterial activity against staphylococcus aureus (p = 0.92, p = 0.14, and p = 0.48 respectively). CONCLUSION FG can be considered a promising additive to GICs to promote its anti-cariogenic effects, however, these antibacterial effects are only useful in the short term, as aging adversely affected their mechanical properties. The 2.5 wt % FG/GICs is suggested to be the most encouraging, as after aging, it represented the highest compressive strength among all groups, while its hardness values were at least comparable to that of conventional glass ionomer. CLINICAL SIGNIFICANCE FG/GICs can be considered an anti-cariogenic restoration in temporary restorative interventions, as in certain cases in deciduous teeth where considerable esthetics may be required, especially those with difficult moisture control, where neither resin composite restorations nor amalgam restorations will be indicated. It can also be used for patients with high caries index or in atraumatic restorative treatment (ART) in low-income countries.
Collapse
|
15
|
Çelik ZC, Elbek Cubukcu C. Quantification of Surface Relation Between Experimental Polylactic Acid Dental Matrix and Type II Glass Ionomers Using Peel Adhesion Test and Fourier Transform Infrared Spectroscopy. Cureus 2023; 15:e35599. [PMID: 36874305 PMCID: PMC9977199 DOI: 10.7759/cureus.35599] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 02/27/2023] [Indexed: 03/04/2023] Open
Abstract
AIM Type II glass ionomer cement (GIC) is a posterior restorative material that is generally not recommended for interaction with stainless steel due to chemical ion exchange. The purpose of this study is to quantify the surface relation of experimental three-dimensional (3D)-printed polylactic acid (PLA) and type II GIC using the peel adhesion test and Fourier transform infrared spectroscopy (FT-IR). MATERIALS AND METHODS Experimental PLA dental matrix specimens were 3D printed in the form of an open circumferential dental matrix (75x6x0.0055 mm) using a fused deposition modeling (FDM) machine. The peel resistance test (ASTM D1876) was applied to determine the relative peel resistance of the adhesive bonds between the PLA dental matrix, traditional circumferential stainless steel (SS) matrix, and GIC. The PLA bands were characterized using an FT-IR spectrophotometer (Spectrum 100, PerkinElmer Inc., Waltham, MA, USA) for the simultaneous determination of the chemical relationships of the surfaces before and after the GIC was set in a simulated class II cavity model. RESULTS The mean peel strengths (P/b) ± standard deviations of the PLA and SS dental matrix bands were 0.0017 ± 0.0003 N/mm and 0.3122 ± 0.0042 N/mm, respectively. The -C H stretching was observed at 3383 cm-1 after adhesion, which corresponded to vibrational movements on the surface. CONCLUSION It required ~184 times less force to separate the GIC from the PLA surface compared to the traditional SS matrix. Additionally, there was no evidence of a new chemical bond or strong chemical interaction occurring between the GIC and the experimental PLA dental matrix.
Collapse
|
16
|
Effect of radiant heat induced by a diode laser (445 nm) on setting process of glass-ionomer cements monitored by Fourier transform infrared spectroscopy. Dent Mater 2022; 38:1947-1955. [DOI: 10.1016/j.dental.2022.11.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2022] [Revised: 10/12/2022] [Accepted: 11/11/2022] [Indexed: 11/18/2022]
|
17
|
Biological and Physicochemical Characterization of Self-Adhesive Protective Coating Dental Restorative Material after Incorporation of Antibacterial Nanoparticles. Polymers (Basel) 2022; 14:polym14204280. [PMID: 36297861 PMCID: PMC9611372 DOI: 10.3390/polym14204280] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2022] [Revised: 10/04/2022] [Accepted: 10/06/2022] [Indexed: 11/16/2022] Open
Abstract
This study evaluated the physicochemical and antibacterial properties of EQUIATM coat liquid (E) after incorporation of zinc oxide (ZnO) and titanium dioxide (TiO2) nanoparticles. ZnO and TiO2 (1 wt.% and 2 wt.%) were dispersed in EQUIA coat. Principal component analysis (PCA) and cluster analysis were performed to visualize systemic variation. Antibacterial activity was evaluated by colony-forming units and crystal violet staining using Streptococcusmutans and Lactobacillusacidophilus after 24 h, 48 h, and 72 h, and the microstructure was studied by scanning electron microscopy. The weight change was analyzed at 1 and 21 days. The PCA for TiO2- and ZnO-based groups showed 100% variance at all spectral ranges at 600−800/cm and 800−1200/cm, whereas 1200−1800/cm and 2700−3800/cm spectral regions demonstrated 99% variance. The absorbance values were significant (p < 0.05) for both nanoparticles-based adhesives, and the specimens with 2 wt.% ZnO showed the maximum response by minimum bacterial attachment, and the control group showed the least response by maximum attachment. The weight change percentage was reduced after the incorporation of antibacterial nanoparticles. It is suggested that EQUIATM coat containing nanoparticles exhibits promising results, and it may be recommended to clinically use as an improved coating material.
Collapse
|
18
|
Morais AMDS, Pereira YMR, Souza-Araújo IJD, Silva DF, Pecorari VGA, Gomes OP, Nociti-Júnior FH, Puppin-Rontani RM, Vieira-Junior WF, Lisboa-Filho PN, Kantovitz KR. TiO2 nanotube-containing glass ionomer cements display reduced aluminum release rates. Braz Oral Res 2022; 36:e097. [PMID: 35830141 DOI: 10.1590/1807-3107bor-2022.vol36.0097] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2021] [Accepted: 04/19/2022] [Indexed: 11/21/2022] Open
Abstract
Titanium dioxide nanotubes (TiO2-nts) were incorporated into a glass ionomer cement (GIC) with improved mechanical properties and antibacterial activity. The aims of the present in vitro study were to define the elemental characterization, aluminum (Al) release rate, and initial working time for GIC reinforced with TiO2-nts, in an experimental caries model. TiO2-nts were incorporated into GIC powder components at 5% by weight, and compared with unblended GIC. Experimental approaches used energy-dispersive spectrometry (EDS), atomic absorption spectrophotometry (AAS), and brightness loss to define surface element properties, Al release rates, and initial working time, respectively. Statistical analysis was performed by 2-way ANOVA, Tukey's test, generalized linear models, and Student's t test (a = 0.05). EDS data analysis revealed that TiO2-nts incorporated into GIC had no significant impact on the typical elemental composition of GICs in an in vitro caries model. Regarding the demineralizing solution, GIC with TiO2-nt significantly decreased the Al release rate, compared with the control group (p < 0.0001). Moreover, TiO2-nt incorporated into GIC did not alter the initial working time of the material (p > 0.05). These findings add information to our scientific body of knowledge concerning the potential impact of TiO2-nt on the performance of conventional GICs.
Collapse
Affiliation(s)
- Ana Mara da Silva Morais
- Faculdade São Leopoldo Mandic - SLMandic, School of Dentistry, Dental Material Area, Campinas, SP, Brazil
| | | | - Isaac Jordão de Souza-Araújo
- University of Campinas - Unicamp, Piracicaba Dental School, Department of Restorative Dentistry, Piracicaba, SP, Brazil
| | - Daniel Furtado Silva
- Federal University of Paraíba - UFPB, School of Dentistry, Restorative Dentistry Area, João Pessoa, PB, Brazil
| | | | - Orisson Ponce Gomes
- São Paulo State University - Unesp, School of Sciences, Department of Physics, Bauru, SP, Brazil
| | | | - Regina Maria Puppin-Rontani
- University of Campinas - Unicamp, Piracicaba Dental School, Department of Pediatric Dentistry, Piracicaba, SP, Brazil
| | | | | | - Kamila Rosamilia Kantovitz
- Faculdade São Leopoldo Mandic - SLMandic, School of Dentistry, Dental Material Area, Campinas, SP, Brazil
| |
Collapse
|
19
|
Ismail HS, Ali AI, Mehesen RE, Garcia-Godoy F, Mahmoud SH. In vitro marginal and internal adaptation of four different base materials used to elevate proximal dentin gingival margins. J Clin Exp Dent 2022; 14:e550-e559. [PMID: 35912027 PMCID: PMC9328484 DOI: 10.4317/jced.59652] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2022] [Accepted: 06/06/2022] [Indexed: 11/22/2022] Open
Abstract
Background There is still debate about the most appropriate restorative material category to relocate the proximal deep cervical margins, thus, this study aimed to compare the marginal and internal adaptation of four base materials used for deep margin elevation, and to evaluate each base material/overlying composite interface.
Material and Methods Fifty six molars received class II cavities with dentin/cementum gingival margins. They were divided into four groups and their gingival margins were elevated using either; resin modified glass ionomer (RMGI), highly viscous conventional glass ionomer (HV-GIC), flowable bulk fill resin composite (Bulk Flow) and bioactive ionic resin (Activa). The rest of the cavities were completed with the same overlying composite. Half of each group was either; kept in sterile water for 1 week, or subjected to 18 months water storage and 15,000 thermal cycles. Base materials/gingival dentin interfaces were examined under a scanning electron microscope at different magnifications, and percentage of continuous margin (% CM) and maximum gap width (MGW) were analyzed, in addition to base materials/overlying composite interfaces evaluations. % CM values were statistically analyzed using Two-way analysis of variance, Tukey post hoc tests (at p<0.05) and Pearson’s correlation while MGW values were analyzed using Kruskal–Wallis, Mann–Whitney U tests and Spearmen correlation
Results Both Bulk Flow and Activa had better marginal integrity than RMGI and HV-GIC. All base materials were adversely affected by aging. All base materials/overlying composite interfaces were continuous and age defying.
Conclusions In terms of marginal integrity, Bulk Flow and Activa might be preferable for proximal dentin margin elevation under direct restoration compared to the other tested base materials. Key words:Deep proximal margin, interface analysis, marginal quality, open sandwich technique.
Collapse
Affiliation(s)
- Hoda S Ismail
- Operative Dentistry Department, Faculty of Dentistry, Mansoura University, Mansoura, Egypt
| | - Ashraf I Ali
- Operative Dentistry Department, Faculty of Dentistry, Mansoura University, Mansoura, Egypt
| | - Rabab El Mehesen
- Operative Dentistry Department, Faculty of Dentistry, Mansoura University, Mansoura, Egypt
| | - Franklin Garcia-Godoy
- Department of Bioscience Research, College of Dentistry, University of Tennessee Health Science Center, Memphis, Tennessee, USA.,The Forsyth Institute, Cambridge, MA, USA
| | - Salah H Mahmoud
- Operative Dentistry Department, Faculty of Dentistry, Mansoura University, Mansoura, Egypt
| |
Collapse
|
20
|
DURHAN MA, EREN GİRAY F, TUNA İNCE EB, TUZUNER T, YETKİNER A, ERSİN N, KARGUL B. Randomized Clinical Trial of Heated High Viscosity Glass Ionomer Class II Restorations in Deciduous Molars: 12 Months Follow Up. CLINICAL AND EXPERIMENTAL HEALTH SCIENCES 2022. [DOI: 10.33808/clinexphealthsci.997219] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Objective: New generation High Viscosity Glass Ionomer Cements (HVGICs) have enhanced physical and mechanical properties. By effectively closing the restoration margin, it ensures that the restorations will last longer. The aim of this study was to investigate the clinical performances of heat-cured versus non heated HVGIC in class II restorations of deciduous molars.
Methods: This randomized, split mouth, multicentre study was performed in four different centres. A total of 250 deciduous molars from 88 individuals were randomly allocated to one of the following groups: 1) non-heated (n = 125) 2) heated (n = 125) and restored with a HVGIC using LED light for heat application. Restorations were clinically evaluated according to the modified USPHS at the baseline, 6 months and 12 months. The survival analysis was performed by Kaplan Meier and Life Tables. This study was retrospectively registered to the ClinicalTrials.gov with the ID number of NCT04291872 at 2nd March 2020.
Results: No statistically significant differences were found between the groups regarding to modified USPHS criteria (p>0.05). Success rate in retention criteria was 94.1% of the heat-cured and 92.6% of the non-heated restorations after 12 months. The mean survival time was 11.8 ±0.1 months in the heated group, while 11.9±0.1 months in the non-heated group.
Conclusion: The heat treated HVGIC for Class II restorations did not show any significant differences in 12 months’ follow-up compared with the conventional technique.
Collapse
Affiliation(s)
| | | | | | - Tamer TUZUNER
- KARADENIZ TECHNICAL UNIVERSITY, FACULTY OF DENTISTRY
| | | | | | | |
Collapse
|
21
|
Veček NN, Par M, Sever EK, Miletić I, Krmek SJ. The Effect of a Green Smoothie on Microhardness, Profile Roughness and Color Change of Dental Restorative Materials. Polymers (Basel) 2022; 14:polym14102067. [PMID: 35631949 PMCID: PMC9145769 DOI: 10.3390/polym14102067] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2022] [Revised: 05/12/2022] [Accepted: 05/17/2022] [Indexed: 11/16/2022] Open
Abstract
Acidic drinks are known to exert negative effects on the surface properties of dental restorative materials. However, the effect of increasingly popular green smoothie drinks has not been addressed so far. The present study investigated the effect of cyclic immersions (5 min daily over 30 days) in a green smoothie drink on the surface properties of contemporary dental restorative materials, including resin composites, an alkasite, and a glass hybrid. Vickers microhardness, profile roughness, and perceptible color change in the CIE L* a* b* color space were evaluated as clinically relevant properties of the material surface. After 30-day green smoothie immersion, microhardness values either decreased by 8–28% (for resin composites) or increased by up to 91% (for glass hybrid). The increase in profile roughness (Ra parameter) of smoothie-immersed specimens was 7–26 times higher compared to the control group. The perceptible color change (ΔE*) in the smoothie group was 3–8 times higher compared to the control group. Overall, this study demonstrated that daily exposure of dental restorations made from resin composites, alkasites, and glass hybrid materials to a green smoothie drink can significantly accelerate material degradation, which is reflected as surface softening, as well as higher roughness and higher perceptible color change.
Collapse
Affiliation(s)
| | - Matej Par
- Department of Endodontics and Restorative Dentistry, School of Dental Medicine, University of Zagreb, Gunduliceva 5, 10000 Zagreb, Croatia; (E.K.S.); (I.M.); (S.J.K.)
- Correspondence:
| | - Eva Klarić Sever
- Department of Endodontics and Restorative Dentistry, School of Dental Medicine, University of Zagreb, Gunduliceva 5, 10000 Zagreb, Croatia; (E.K.S.); (I.M.); (S.J.K.)
| | - Ivana Miletić
- Department of Endodontics and Restorative Dentistry, School of Dental Medicine, University of Zagreb, Gunduliceva 5, 10000 Zagreb, Croatia; (E.K.S.); (I.M.); (S.J.K.)
| | - Silvana Jukić Krmek
- Department of Endodontics and Restorative Dentistry, School of Dental Medicine, University of Zagreb, Gunduliceva 5, 10000 Zagreb, Croatia; (E.K.S.); (I.M.); (S.J.K.)
| |
Collapse
|
22
|
Roberts H, Berzins D, Nicholson J. Long-Term Water Balance Evaluation in Glass Ionomer Restorative Materials. MATERIALS 2022; 15:ma15030807. [PMID: 35160751 PMCID: PMC8836498 DOI: 10.3390/ma15030807] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/02/2021] [Revised: 01/13/2022] [Accepted: 01/14/2022] [Indexed: 02/01/2023]
Abstract
The complex role of water in glass ionomer cement (polyalkenoate) dental restorative materials has been studied, but much of the present understanding concerning water balance within these materials is based on very early studies and short-term experiments. This study evaluated the nature of the water species of six conventional and four resin modified glass ionomer restorative materials over 3 years using thermogravimetric analysis techniques. Materials were prepared, placed in crucibles, and stored in physiologic phosphate buffered saline and evaluated at 24 h, 1 week, and then at 1, 3, 6, 9, 12, 18, 24, 30 and 36 months. All materials demonstrated a significant increase in unbound water percentage content but except for the resin modified materials, the enthalpy required to remove the unbound water species did not significantly change over 36 months. Also, bound water content percentage and removal enthalpy was established at 24 h, as no significant increase was noted in both bound water content and removal enthalpy over the course of this evaluation. This study suggests that unbound water species may increase with time and is loosely held except for the resin modified materials. Protective coatings placement and re-evaluation are prudent to prevent unbound water loss.
Collapse
Affiliation(s)
- Howard Roberts
- Dental Biomaterials Research, College of Dentistry, University of Kentucky, Lexington, KY 40536, USA
- Correspondence: ; Tel.: +1-(847)-910-4255
| | - David Berzins
- Graduate Dental Biomaterials, School of Dentistry, Marquette University, Milwaukee, WI 53233, USA;
| | - John Nicholson
- Bluefield Centre for Biomaterials, UK and Dental Physical Sciences, Barts & The London School of Medicine and Dentistry, Queen Mary University of London, London E1 4NS, UK;
| |
Collapse
|
23
|
Ismail HS, Morrow BR, Ali AI, Mehesen RE, Garcia-Godoy F, Mahmoud SH. Correlation between different methodologies used to evaluate the marginal adaptation of proximal dentin gingival margins elevated using a glass hybrid. RESTORATIVE DENTISTRY & ENDODONTICS 2022; 47:e36. [DOI: 10.5395/rde.2022.47.e36] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/07/2022] [Revised: 05/20/2022] [Accepted: 06/15/2022] [Indexed: 11/11/2022]
Affiliation(s)
- Hoda S. Ismail
- Department of Operative Dentistry Faculty of Dentistry, Mansoura University, Mansoura, Egypt
- Department of Bioscience Research, College of Dentistry, University of Tennessee Health Science Center, Memphis, TN, USA
| | - Brian R. Morrow
- Department of Bioscience Research, College of Dentistry, University of Tennessee Health Science Center, Memphis, TN, USA
| | - Ashraf I. Ali
- Department of Operative Dentistry Faculty of Dentistry, Mansoura University, Mansoura, Egypt
| | - Rabab El. Mehesen
- Department of Operative Dentistry Faculty of Dentistry, Mansoura University, Mansoura, Egypt
| | - Franklin Garcia-Godoy
- Department of Bioscience Research, College of Dentistry, University of Tennessee Health Science Center, Memphis, TN, USA
- Adjunct Faculty, The Forsyth Institute, Cambridge, MA, USA
| | - Salah H. Mahmoud
- Department of Operative Dentistry Faculty of Dentistry, Mansoura University, Mansoura, Egypt
| |
Collapse
|
24
|
Ali M, Okamoto M, Watanabe M, Huang H, Matsumoto S, Komichi S, Takahashi Y, Hayashi M. Biological properties of lithium-containing surface pre-reacted glass fillers as direct pulp-capping cements. Dent Mater 2021; 38:294-308. [PMID: 34953627 DOI: 10.1016/j.dental.2021.12.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2021] [Revised: 11/25/2021] [Accepted: 12/08/2021] [Indexed: 11/18/2022]
Abstract
OBJECTIVE Surface pre-reacted glass fillers (S-PRG) can release different types of ions and in our previous study, we modified these fillers with lithium chloride (S-PRG/Li-100 mM) to induce reparative dentin formation by activating the Wnt/β-catenin signaling pathway. Here, we assessed the biological performance of S-PRG/Li-100 mM and compared it with that of mineral trioxide aggregate (MTA) and S-PRG without additives. METHODS In vivo studies were conducted on male Wistar rats using Masson's trichrome staining in pulp-capped molars. The test materials were implanted subcutaneously to evaluate their capacity for vascularization and biocompatibility. The ability of the test materials to form apatite was tested by immersing them in simulated body fluid. Rhodamine-B staining was conducted to assess their sealing ability in bovine teeth, while their antibacterial activity was evaluated against Streptococcus mutans and Lactobacillus casei in terms of colony-forming units and by live/dead staining. RESULTS Masson's trichrome staining and tissue-implantation tests confirmed the biocompatibility of S-PRG/Li-100 mM and it was similar to that of MTA and S-PRG; inflammation regression was observed 14 days after operation in the subcutaneous tissues. S-PRG/Li-100 mM promoted the formation of apatite on its surface. Both the S-PRG groups showed higher sealing capability and bactericidal/bacteriostatic activity against oral bacterial biofilms than MTA. SIGNIFICANCE Lithium-containing surface pre-reacted glass cements exhibit better antibacterial and sealing capabilities than MTA, suggesting their potential as high-performance direct pulp-capping materials.
Collapse
Affiliation(s)
- Manahil Ali
- Department of Restorative Dentistry and Endodontology, Graduate School of Dentistry, Osaka University, 1-8, Yamadaoka, Suita, Osaka 565-0871, Japan; Department of Restorative Dentistry, Faculty of Dentistry, University of Khartoum, P.O. 11111 Khartoum, Sudan.
| | - Motoki Okamoto
- Department of Restorative Dentistry and Endodontology, Graduate School of Dentistry, Osaka University, 1-8, Yamadaoka, Suita, Osaka 565-0871, Japan.
| | - Masakatsu Watanabe
- Department of Restorative Dentistry and Endodontology, Graduate School of Dentistry, Osaka University, 1-8, Yamadaoka, Suita, Osaka 565-0871, Japan.
| | - Hailing Huang
- Department of Restorative Dentistry and Endodontology, Graduate School of Dentistry, Osaka University, 1-8, Yamadaoka, Suita, Osaka 565-0871, Japan.
| | - Sayako Matsumoto
- Department of Restorative Dentistry and Endodontology, Graduate School of Dentistry, Osaka University, 1-8, Yamadaoka, Suita, Osaka 565-0871, Japan.
| | - Shungo Komichi
- Department of Restorative Dentistry and Endodontology, Graduate School of Dentistry, Osaka University, 1-8, Yamadaoka, Suita, Osaka 565-0871, Japan.
| | - Yusuke Takahashi
- Department of Restorative Dentistry and Endodontology, Graduate School of Dentistry, Osaka University, 1-8, Yamadaoka, Suita, Osaka 565-0871, Japan.
| | - Mikako Hayashi
- Department of Restorative Dentistry and Endodontology, Graduate School of Dentistry, Osaka University, 1-8, Yamadaoka, Suita, Osaka 565-0871, Japan.
| |
Collapse
|
25
|
Neves AB, Lopes LIG, Bergstrom TG, da Silva ASS, Lopes RT, Neves ADA. Porosity and pore size distribution in high-viscosity and conventional glass ionomer cements: a micro-computed tomography study. Restor Dent Endod 2021; 46:e57. [PMID: 34909421 PMCID: PMC8636077 DOI: 10.5395/rde.2021.46.e57] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2020] [Revised: 02/08/2021] [Accepted: 03/10/2021] [Indexed: 12/03/2022] Open
Abstract
Objectives This study aimed to compare and evaluate the porosity and pore size distribution of high-viscosity glass ionomer cements (HVGICs) and conventional glass ionomer cements (GICs) using micro-computed tomography (micro-CT). Materials and Methods Forty cylindrical specimens (n = 10) were produced in standardized molds using HVGICs and conventional GICs (Ketac Molar Easymix, Vitro Molar, MaxxionR, and Riva Self-Cure). The specimens were prepared according to ISO 9917-1 standards, scanned in a high-energy micro-CT device, and reconstructed using specific parameters. After reconstruction, segmentation procedures, and image analysis, total porosity and pore size distribution were obtained for specimens in each group. After checking the normality of the data distribution, the Kruskal-Wallis test followed by the Student-Newman-Keuls test was used to detect differences in porosity among the experimental groups with a 5% significance level. Results Ketac Molar Easymix showed statistically significantly lower total porosity (0.15%) than MaxxionR (0.62%), Riva (0.42%), and Vitro Molar (0.57%). The pore size in all experimental cements was within the small-size range (< 0.01 mm3), but Vitro Molar showed statistically significantly more pores/defects with a larger size (> 0.01 mm3). Conclusions Major differences in porosity and pore size were identified among the evaluated GICs. Among these, the Ketac Molar Easymix HVGIC showed the lowest porosity and void size.
Collapse
Affiliation(s)
- Aline Borburema Neves
- Department of Pediatric Dentistry and Orthodontics, Universidade Federal do Rio de Janeiro - UFRJ, School of Dentistry, Rio de Janeiro, RJ, Brazil
| | - Laísa Inara Gracindo Lopes
- Department of Pediatric Dentistry and Orthodontics, Universidade Federal do Rio de Janeiro - UFRJ, School of Dentistry, Rio de Janeiro, RJ, Brazil
| | - Tamiris Gomes Bergstrom
- Department of Pediatric Dentistry and Orthodontics, Universidade Federal do Rio de Janeiro - UFRJ, School of Dentistry, Rio de Janeiro, RJ, Brazil
| | - Aline Saddock Sá da Silva
- Laboratory of Nuclear Instrumentation, Universidade Federal do Rio de Janeiro - UFRJ, Rio de Janeiro, RJ, Brazil
| | - Ricardo Tadeu Lopes
- Laboratory of Nuclear Instrumentation, Universidade Federal do Rio de Janeiro - UFRJ, Rio de Janeiro, RJ, Brazil
| | - Aline de Almeida Neves
- Department of Pediatric Dentistry and Orthodontics, Universidade Federal do Rio de Janeiro - UFRJ, School of Dentistry, Rio de Janeiro, RJ, Brazil
| |
Collapse
|
26
|
Kim WS, Kim KH. Percutaneous osteoplasty for painful bony lesions: a technical survey. Korean J Pain 2021; 34:375-393. [PMID: 34593656 PMCID: PMC8494954 DOI: 10.3344/kjp.2021.34.4.375] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2021] [Revised: 07/09/2021] [Accepted: 07/14/2021] [Indexed: 12/01/2022] Open
Abstract
Percutaneous osteoplasty (POP) is defined as the injection of bone cement into various painful bony lesions, refractory to conventional therapy, as an extended technique of percutaneous vertebroplasty (PVP). POP can be applied to benign osteochondral lesions and malignant metastatic lesions throughout the whole skeleton, whereas PVP is restricted to the vertebral body. Common spinal metastases occur in the thoracic (70%), lumbosacral (20%), and cervical (10%) vertebrae, in order of frequency. Extraspinal metastases into the ribs, scapulae, sternum, and humeral head commonly originate from lung and breast cancers; extraspinal metastases into the pelvis and femoral head come from prostate, urinary bladder, colon, and uterine cervical cancers. Pain is aggravated in the dependent (or weight bearing) position, or during movement (or respiration). The tenderness and imaging diagnosis should match. The supposed mechanism of pain relief in POP is the augmentation of damaged bones, thermal and chemical ablation of the nociceptive nerves, and local inhibition of tumor invasion. Adjacent (facet) joint injections may be needed prior to POP (PVP). The length and thickness of the applied needle should be chosen according to the targeted bone. Bone cement is also selected by its osteoconduction, osteoinduction, and osteogenesis. Needle route should be chosen as a shortcut to reach the target bony lesions, without damage to the nerves and vessels. POP is a promising minimally invasive procedure for immediate pain relief. This review provides a technical survey for POPs in painful bony lesions.
Collapse
Affiliation(s)
- Won-Sung Kim
- Department of Anesthesia and Pain Medicine, School of Medicine, Pusan National University, Yangsan, Korea
| | - Kyung-Hoon Kim
- Department of Anesthesia and Pain Medicine, School of Medicine, Pusan National University, Yangsan, Korea
| |
Collapse
|
27
|
Wawrzyńczak A, Kłos J, Nowak I, Czarnecka B. Surface Studies on Glass Powders Used in Commercial Glass-Ionomer Dental Cements. Molecules 2021; 26:5279. [PMID: 34500713 PMCID: PMC8433982 DOI: 10.3390/molecules26175279] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2021] [Revised: 08/20/2021] [Accepted: 08/28/2021] [Indexed: 11/30/2022] Open
Abstract
The surface properties of three commercial ionomer glass powders, i.e., Fuji IX, Kavitan Plus and Chemadent G-J-W were studied. Samples were analyzed by X-ray fluorescence spectroscopy (XRF), and the density was determined by gas pycnometry. Morphology was studied using scanning electron microscopy (SEM) and laser diffraction (LD) technique, whereas low-temperature nitrogen sorption measurements determined textural parameters like specific surface area and pore volume. Thermal transformations in the materials studied were evaluated by thermogravimetric analysis (TGA), which was carried out in an inert atmosphere between 30 °C and 900 °C. XRF showed that Fuji IX and Kavitan Plus powders were strontium-based, whereas Chemadent G-J-W powder was calcium-based. Powders all had a wide range of particle sizes under SEM and LD measurements. Specific surface areas and pore volumes were in the range 1.42-2.73 m2/g and 0.0029 to 0.0083 cm3/g, respectively, whereas densities were in the range 2.6428-2.8362 g/cm3. Thermogravimetric analysis showed that the glass powders lost mass in a series of steps, with Fuji IX powder showing the highest number, some of which are attributed to the dehydration and decomposition of the polyacrylic acid present in this powder. Mass losses were more straightforward for the other two glasses. All three powders showed distinct losses at around 780 °C and 835 °C, suggesting that similar dehydration steps occur in all these glasses. Other steps, which differed between glass powders, are attributed to variations in states of water-binding on their surfaces.
Collapse
Affiliation(s)
- Agata Wawrzyńczak
- Faculty of Chemistry, Adam Mickiewicz University in Poznań, Uniwersytetu Poznańskiego 8, 61-614 Poznań, Poland; (A.W.); (J.K.); (I.N.)
| | - Jacek Kłos
- Faculty of Chemistry, Adam Mickiewicz University in Poznań, Uniwersytetu Poznańskiego 8, 61-614 Poznań, Poland; (A.W.); (J.K.); (I.N.)
- Department of Biomaterials and Experimental Dentistry, Poznan University of Medical Sciences, Bukowska 70, 60-812 Poznań, Poland
| | - Izabela Nowak
- Faculty of Chemistry, Adam Mickiewicz University in Poznań, Uniwersytetu Poznańskiego 8, 61-614 Poznań, Poland; (A.W.); (J.K.); (I.N.)
| | - Beata Czarnecka
- Department of Biomaterials and Experimental Dentistry, Poznan University of Medical Sciences, Bukowska 70, 60-812 Poznań, Poland
| |
Collapse
|
28
|
Lopes L, Terada R, de Castro-Hoshino LV, de Oliveira B, Pascotto RC, Baesso ML, Tabchoury C, Sato F, Nicholson JW, Sidhu SK. In Vitro Evaluation of the Stabilization Time of Chemical Bonds During Setting Reaction and Microhardness of Preheated Glass-Ionomer Cements. Oper Dent 2021; 46:208-218. [PMID: 34192337 DOI: 10.2341/19-250-l] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/20/2020] [Indexed: 11/23/2022]
Abstract
OBJECTIVES To evaluate the effect of preheating glass-ionomer cement (GIC) restorative materials on stabilization time (ST) of their metal carboxylate bonds and on microhardness. METHODS AND MATERIALS Two conventional highviscosity GICs, Ketac Universal (3M ESPE) and Equia Forte (GC), were evaluated. The thermographic camera was used to measure the temperature inside the glass-ionomer cement capsules before and after heating. The preheating of capsules was performed at 54°C for 30 seconds in a commercial device. Characterization of ST in the GICs was determined by Fourier Transform Infrared (FTIR) spectroscopy. For this, 10 samples of each material were prepared, five in the non-preheated group (control) and five with preheating. FTIR spectra were obtained 10 minutes after mixing (control group) or after heating and then every 10 minutes for 120 minutes. For the microhardness test, 20 cylindrical specimens (3 mm height × 6 mm diameter) were prepared for each material (10 preheated, 10 control). The microhardness was determined at three time intervals: 10 minutes after mixing, after the ST as detected through the FTIR part of the study, and after one week. Knoop microhardness was assessed using a diamond indenter with a 25 g load and 15 seconds dwell time. RESULTS Ketac Universal showed an increase in temperatures of 15.7°C for powder and 3.6°C for liquid, while Equia Forte showed 16.4°C for powder and 8.5°C for liquid. FTIR spectra indicated that preheating reduced the ST for Equia Forte but increased it for Ketac Universal. Preheating increased the initial microhardness (T1) of Equia Forte. With maturation over one week, it was observed that preheating significantly improved the microhardness of both materials compared with the control specimens. CONCLUSION Preheating influenced the ST and the microhardness of Ketac Universal and Equia Forte. The ST and microhardness of Ketac Universal increased after seven days, whereas Equia Forte showed a reduced ST and increased microhardness from the outset.
Collapse
|
29
|
Tsuzuki FM, Pascotto RC, Malacarne LC, Bento AC, Medina Neto A, de Castro-Hoshino LV, Souza M, Nicholson JW, Baesso ML. Studies of the early stages of the dynamic setting process of chemically activated restorative glass-ionomer cements. Biomater Investig Dent 2021; 8:39-47. [PMID: 33855301 PMCID: PMC8018555 DOI: 10.1080/26415275.2021.1898964] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
Objective To evaluate the early stages of the setting process of chemically activated restorative glass-ionomer cements (GICs). Material and methods Five GICs were evaluated (n = 5): Equia Forte (GC), Equia Forte HT (GC), Ketac Universal (3M ESPE), Maxxion R (FGM) and Riva Self Cure (SDI) by Thermography, Fourier Transform Infrared Attenuated Total Reflectance Spectroscopy (FTIR-ATR) and Gillmore needle indentation mechanical testing. The FTIR-ATR spectra showed the formation of metal carboxylates within the cements and enabled the stabilization time (ST) to be determined and the thermographic camera measured the temperature field images in the sample. Data were statistically analyzed by ANOVA and Tukey–Kramer (α = 5%). Results The Gillmore needle test showed that the order of hardening was opposite to the order of ST values determined by FTIR. The results with the thermographic camera showed two stages of temperature variation, which coincided with the evolution of specific infrared bands. The exception was Maxxion R, which showed only a single step change in temperature. Conclusion The early stages of the GIC setting reaction show temperature changes, both endothermic and exothermic, at specific times, confirming the occurrence of individual chemical reactions. The early setting involves reactions other than carboxylate formation. Significance: This study gives further detail of the early stages of the setting of GICs, and past research regarding the setting reaction of GIC.
Collapse
Affiliation(s)
| | - Renata C Pascotto
- Department of Dentistry, State University of Maringa, Maringá, Brazil
| | - Luis C Malacarne
- Department of Physics, State University of Maringa, Maringá, Brazil
| | - Antonio C Bento
- Department of Physics, State University of Maringa, Maringá, Brazil
| | | | | | - Monique Souza
- Department of Physics, State University of Maringa, Maringá, Brazil
| | - John W Nicholson
- Institute of Dentistry, Barts & The London School of Medicine and Dentistry, Queen Mary University of London, London, UK
| | - Mauro L Baesso
- Department of Physics, State University of Maringa, Maringá, Brazil
| |
Collapse
|
30
|
de Lima Navarro MF, Pascotto RC, Borges AFS, Soares CJ, Raggio DP, Rios D, Bresciani E, Molina GF, Ngo HC, Miletić I, Frencken J, Wang L, Menezes-Silva R, Puppin-Rontani RM, de Carvalho RM, Gurgan S, Leal SC, Tüzüner T, Fagundes TC, Nicholson JW, Sidhu SK. Consensus on glass-ionomer cement thresholds for restorative indications. J Dent 2021; 107:103609. [PMID: 33610589 DOI: 10.1016/j.jdent.2021.103609] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2020] [Revised: 02/14/2021] [Accepted: 02/15/2021] [Indexed: 11/28/2022] Open
Abstract
OBJECTIVE The aim of this paper is to present the results of a consensus meeting on the threshold property requirements for the clinical use of conventional glass-ionomer cements (GICs) for restorative indications. METHODS Twenty-one experts on GICs evaluated the results of tests on mechanical and optical properties of 18 different brands of restorative GICs: Bioglass R [B], Chemfil Rock [CR], Equia Forte [EF], Gold Label 2 [GL2], Gold Label 9 [GL9], Glass Ionomer Cement II [GI], Ionglass [IG], Ion Z [IZ], Ionomaster [IM], Ionofil Plus [IP], Ionostar Plus [IS], Ketac Molar Easymix [KM], Magic Glass [MG], Maxxion R [MA], Riva Self Cure [R], Vidrion R [V], Vitro Fil [VF] and Vitro Molar [VM]. All experiments were carried out by a team of researchers from Brazil and England following strict protocols, under the same laboratory conditions throughout, and maintaining data integrity. RESULTS There was consensus on: determining as primary properties of the material: compressive strength, microhardness, acid erosion and fluoride release, and as secondary properties: contrast ratio and translucency parameter, in order to rank the materials. Seven brands were below the thresholds for restorative indications: IZ, IM, IG, MA, VF, B and MG. CONCLUSIONS Based on the primary properties adopted as being essential for restorative indications, the conventional restorative GICs that met the thresholds and could be considered suitable as long-term restorative materials were: EF, GI, GL9, KM, IP, GL2, IS, CR, V, VM and R. A decision-making process to select the best GIC must also include results from clinical trials. CLINICAL SIGNIFICANCE This study provides a ranking of GICs that could be considered suitable as long-term restorative materials based on their main properties.
Collapse
Affiliation(s)
- Maria Fidela de Lima Navarro
- Department of Restorative Dentistry, Bauru School of Dentistry, University of São Paulo, Alameda Dr. Octávio Pinheiro Brisolla, 9-75 - Jardim Brasil, 17012-901, Bauru, Brazil.
| | - Renata Corrêa Pascotto
- Department of Restorative Dentistry, State University of Maringá, Av. Colombo, 5790 - Jd. Universitário, 87020-900, Maringá, Brazil
| | - Ana Flávia Sanches Borges
- Department of Restorative Dentistry, Bauru School of Dentistry, University of São Paulo, Alameda Dr. Octávio Pinheiro Brisolla, 9-75 - Jardim Brasil, 17012-901, Bauru, Brazil
| | - Carlos José Soares
- Department of Restorative Dentistry, Federal University of Uberlândia, Av. João Naves de Ávila, 2121 - Santa Mônica, 38408-100, Uberlândia, Brazil
| | - Daniela Prócida Raggio
- Department of Orthodontics and Pediatric Dentistry, School of Dentistry, University of São Paulo, Av. Prof. Lineu Prestes, 2227 - Butantã, 05508-000, São Paulo, Brazil
| | - Daniela Rios
- Department of Restorative Dentistry, Bauru School of Dentistry, University of São Paulo, Alameda Dr. Octávio Pinheiro Brisolla, 9-75 - Jardim Brasil, 17012-901, Bauru, Brazil
| | - Eduardo Bresciani
- Institute of Science and Technology, State University of São Paulo, Av. Eng. Francisco José Longo, 777 - Jardim São Dimas, 12245-00, São José dos Campos, Brazil
| | | | - Hien Chi Ngo
- Dean and Head of School/Director of OHCWA, The University of Western Australia, 512, 17 Monash Avenue, Nedlands, WA 6009, Australia
| | - Ivana Miletić
- School of Dental Medicine, University of Zagreb, Gundulićeva ul. 5, 10000, Zagreb, Croatia
| | - Jo Frencken
- Department of Dentistry, Radboud University Medical Centre, Philips van Leydenlaan 25, 6525 EX, Nijmegen, the Netherlands
| | - Linda Wang
- Department of Restorative Dentistry, Bauru School of Dentistry, University of São Paulo, Alameda Dr. Octávio Pinheiro Brisolla, 9-75 - Jardim Brasil, 17012-901, Bauru, Brazil
| | - Rafael Menezes-Silva
- Department of Restorative Dentistry, Bauru School of Dentistry, University of São Paulo, Alameda Dr. Octávio Pinheiro Brisolla, 9-75 - Jardim Brasil, 17012-901, Bauru, Brazil
| | | | | | - Sevil Gurgan
- Department of Restorative Dentistry, Hacettepe University, 06800, Ankara, Turkey
| | | | | | - Ticiane Cestari Fagundes
- Araçatuba School of Dentistry, State University of São Paulo, Rua José Bonifácio, 1193, 16015-050, Araçatuba, Brazil
| | - John William Nicholson
- Bluefield Centre for Biomaterials, Unit 34, 67-68 Hatton Garden, Holborn, London EC1N 8JY, England, United Kingdom
| | - Sharanbir Kaur Sidhu
- Queen Mary University of London, Mile End Rd, Bethnal Green, London E1 4NS, England, United Kingdom
| |
Collapse
|
31
|
Singh N, Garg A, Mittal R. Comparative evaluation of pull-out bond strength of fiber post using different luting cements in endodontically treated teeth: An in-vitro study. ENDODONTOLOGY 2021. [DOI: 10.4103/endo.endo_7_20] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
|
32
|
Perera D, Yu SCH, Zeng H, Meyers IA, Walsh LJ. Acid Resistance of Glass Ionomer Cement Restorative Materials. Bioengineering (Basel) 2020; 7:E150. [PMID: 33266452 PMCID: PMC7711830 DOI: 10.3390/bioengineering7040150] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2020] [Revised: 11/13/2020] [Accepted: 11/18/2020] [Indexed: 02/03/2023] Open
Abstract
In view of the need for aesthetics, restorations of teeth will typically be completed using tooth colored restorative materials. With the advent of biomimetic restorative materials, such as glass ionomer cements (GIC), much greater emphasis is now being placed on how well such materials can resist the challenge of acids that are present in foods and drinks, or gastric contents that are regurgitated. This laboratory study compared the dissolution and behavior of five GIC materials (GC Fuji® VII, GC Fuji® Bulk, GC Fuji® IX Fast, Fuji® IX Extra and GC Equia® Forte Fil) when exposed to three acids (citric acid, phosphoric acid and lactic acid), versus ultrapure deionized water, which was used as a control. Discs of each material GIC were submerged in solutions and percentage weight changes over time determined. Subsequently, the GIC materials were also placed as a part of standardized Class II sandwich restorations in bovine teeth (n = 20), and submerged in the solutions, and the extent of GIC dissolution and protection of the adjacent tooth was scored. Weight loss increased with time and with acid concentration. Overall, the most soluble material was GC Fuji® IX Extra, while GC Fuji® IX Fast and GC Fuji® Bulk were less soluble, and the least soluble material was GC Equia® Forte Fil. The most destructive solution for both the discs and for GIC restorations in teeth was 10% citric acid, while the least destructive acid was 0.1% lactic acid. The more recent GIC materials GC Fuji® Bulk and GC Equia® Forte Fil showed increased acid resistance over the older GIC materials, and this further justifies their use in open sandwich Class II restorations in more hostile environments.
Collapse
Affiliation(s)
| | | | | | | | - Laurence J. Walsh
- UQ Oral Health Centre, The University of Queensland School of Dentistry, 288 Herston Road, Herston, QLD 4006, Australia; (D.P.); (S.C.H.Y.); (H.Z.); (I.A.M.)
| |
Collapse
|
33
|
Uchimura JYT, Sato F, Santana RG, Menezes-Silva R, Bueno LS, Borges AFS, de Lima Navarro MF, Nicholson JW, Sidhu SK, Pascotto RC. Translucency parameter of conventional restorative glass-ionomer cements. J ESTHET RESTOR DENT 2020; 33:935-942. [PMID: 33188585 DOI: 10.1111/jerd.12685] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/26/2019] [Revised: 10/24/2020] [Accepted: 10/30/2020] [Indexed: 12/01/2022]
Abstract
OBJECTIVE To evaluate the translucency parameter (TP) and contrast ratio (CR) of different conventional restorative glass-ionomer cements (GICs). MATERIALS AND METHODS Eighteen brands of GICs were evaluated. Five disks of each material were made following ISO 9917-1. The luminous reflectance and Central Bureau of the International Commission on Illumination parameters of disks were evaluated using a colorimeter, against backings of white and black, to obtain the translucent parameter and contrast ratio of different brands of glass-ionomer cements. The correlation between translucency parameter and contrast ratio was assessed with the Pearson correlation test. The translucent and contrast ratio parameters values were submitted to the one-way ANOVA and Tukey test for multiple comparisons (p < 0.05). RESULTS There was a strong inverse relationship between CR and TP (r2 = 0.94, p < 0.001). The contrast ratio decreased as translucency increased. There were significant differences in TP and CR among brands (p < 0.001). CONLUSIONS GICs exhibit different translucency and contrast ratio behavior. Some brands of GICs presented very low TP and this condition would be unacceptable for areas with esthetic demands. In addition, TP and CR showed a strong linear relationship. CLINICAL SIGNIFICANCE The results found in this study demonstrated that the knowledge of the translucency and CR of different conventional restorative GICs is important in order to guide clinicians in the selection of restorative GICs for anterior teeth.
Collapse
Affiliation(s)
| | - Francielle Sato
- Department of Physics, State University of Maringá, Maringá, Paraná, Brazil
| | | | - Rafael Menezes-Silva
- Department of Operative Dentistry, Endodontics and Dental Materials, Bauru School of Dentistry, University of São Paulo, Bauru School of Dentistry-FOB-USP Bauru, São Paulo, Brazil
| | - Ligia S Bueno
- Department of Operative Dentistry, Endodontics and Dental Materials, Bauru School of Dentistry, University of São Paulo, Bauru School of Dentistry-FOB-USP Bauru, São Paulo, Brazil
| | - Ana Flávia Sanches Borges
- Department of Operative Dentistry, Endodontics and Dental Materials, Bauru School of Dentistry, University of São Paulo, Bauru School of Dentistry-FOB-USP Bauru, São Paulo, Brazil
| | - Maria Fidela de Lima Navarro
- Department of Operative Dentistry, Endodontics and Dental Materials, Bauru School of Dentistry, University of São Paulo, Bauru School of Dentistry-FOB-USP Bauru, São Paulo, Brazil
| | - John W Nicholson
- Institute of Dentistry, Barts and The London School of Medicine and Dentistry, Queen Mary University of London, London, UK
| | - Sharanbir K Sidhu
- Institute of Dentistry, Barts and The London School of Medicine and Dentistry, Queen Mary University of London, London, UK
| | | |
Collapse
|
34
|
Naksagoon T, Ohsumi T, Takenaka S, Nagata R, Hasegawa T, Maeda T, Noiri Y. Effect of water aging on the anti-biofilm properties of glass ionomer cement containing fluoro-zinc-silicate fillers. BIOFOULING 2020; 36:1090-1099. [PMID: 33349036 DOI: 10.1080/08927014.2020.1856371] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/02/2020] [Revised: 11/09/2020] [Accepted: 11/20/2020] [Indexed: 06/12/2023]
Abstract
A previous study has reported that a novel fluoro-zinc-silicate glass ionomer cement (Caredyne Restore) showed superior anti-biofilm effects by interfering with bacterial adhesion. However, the active ions may degrade with time. This study aimed to assess the valid anti-biofilm effects of Caredyne Restore after being aged by water immersion for 3 weeks. Streptococcus mutans biofilm was allowed to grow on the surface before and after water aging for 24 h using a modified Robbins device flow-cell system. The results showed water aging promoted biofilm formation. Insufficient amount of fluoride and zinc ions were released from Caredyne Restore after water aging under neutral pH condition. An acidic pH is needed to exert effective anti-biofilm properties. As the release of active ions from Caredyne Restore will gradually decrease after the restoration, the restoration may not prevent biofilm formation after 3 weeks while neutral pH is maintained by the buffering capacity of saliva.
Collapse
Affiliation(s)
- Traithawit Naksagoon
- Division of Cariology, Operative Dentistry, and Endodontics, Faculty of Dentistry & Graduate School of Medical and Dental Sciences, Niigata University, Niigata, Japan
- Research Centre for Advanced Oral Science, Faculty of Dentistry & Graduate School of Medical and Dental Sciences, Niigata University, Niigata, Japan
| | - Tatsuya Ohsumi
- Division of Cariology, Operative Dentistry, and Endodontics, Faculty of Dentistry & Graduate School of Medical and Dental Sciences, Niigata University, Niigata, Japan
| | - Shoji Takenaka
- Division of Cariology, Operative Dentistry, and Endodontics, Faculty of Dentistry & Graduate School of Medical and Dental Sciences, Niigata University, Niigata, Japan
| | - Ryoko Nagata
- Division of Cariology, Operative Dentistry, and Endodontics, Faculty of Dentistry & Graduate School of Medical and Dental Sciences, Niigata University, Niigata, Japan
| | - Taisuke Hasegawa
- Division of Cariology, Operative Dentistry, and Endodontics, Faculty of Dentistry & Graduate School of Medical and Dental Sciences, Niigata University, Niigata, Japan
| | - Takeyasu Maeda
- Research Centre for Advanced Oral Science, Faculty of Dentistry & Graduate School of Medical and Dental Sciences, Niigata University, Niigata, Japan
| | - Yuichiro Noiri
- Division of Cariology, Operative Dentistry, and Endodontics, Faculty of Dentistry & Graduate School of Medical and Dental Sciences, Niigata University, Niigata, Japan
| |
Collapse
|
35
|
Panpisut P, Monmaturapoj N, Srion A, Toneluck A, Phantumvanit P. Physical Properties of Glass Ionomer Cement Containing Pre-Reacted Spherical Glass Fillers. Braz Dent J 2020; 31:445-452. [PMID: 32901723 DOI: 10.1590/0103-6440202003276] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2019] [Accepted: 02/10/2020] [Indexed: 01/26/2023] Open
Abstract
The aim of this study was to assess the effect of different commercial liquid phases (Ketac, Riva, and Fuji IX) and the use of spherical pre-reacted glass (SPG) fillers on cement maturation, fluoride release, compressive (CS) and biaxial flexural strength (BFS) of experimental glass ionomer cements (GICs). The experimental GICs (Ketac_M, Riva_M, FujiIX_M) were prepared by mixing SPG fillers with commercial liquid phases using the powder to liquid mass ratio of 2.5:1. FTIR-ATR was used to assess the maturation of GICs. Diffusion coefficient of fluoride (DF) and cumulative fluoride release (CF) in deionized water was determined using the fluoride ion specific electrode (n=3). CS and BFS at 24 h were also tested (n=6). Commercial GICs were used as comparisons. Riva and Riva_M exhibited rapid polyacrylate salt formation. The highest DF and CF were observed with Riva_M (1.65x10-9 cm2/s) and Riva (77 ppm) respectively. Using SPG fillers enhanced DF of GICs on average from ~2.5x10-9 cm2/s to ~3.0x10-9 cm2/s but reduced CF of the materials on average from ~51 ppm to ~42 ppm. The CS and BFS of Ketac_M (144 and 22 MPa) and Fuji IX_M (123 and 30 MPa) were comparable to commercial materials. Using SPG with Riva significantly reduced CS and BFS from 123 MPa to 55 MPa and 42 MPa to 28 MPa respectively. The use of SPG fillers enhanced DF but reduced CF of GICs. Using SPG with Ketac or Fuji IX liquids provided comparable strength to the commercial materials.
Collapse
Affiliation(s)
| | - Naruporn Monmaturapoj
- Assistive Technology and Medical Devices Research Center(A-MED),National Science and Technology Development Agency, Pathum Thani, Thailand
| | - Autcharaporn Srion
- National Metal Materials Technology Center (MTEC), National Science and Technology Development Agency, Pathum Thani, Thailand
| | - Arnit Toneluck
- Faculty of Dentistry, Thammasat University, Pathum Thani, Thailand
| | | |
Collapse
|
36
|
Porter G, Tompkins G, Schwass D, Li K, Waddell J, Meledandri C. Anti-biofilm activity of silver nanoparticle-containing glass ionomer cements. Dent Mater 2020; 36:1096-1107. [DOI: 10.1016/j.dental.2020.05.001] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2020] [Revised: 03/29/2020] [Accepted: 05/05/2020] [Indexed: 12/13/2022]
|
37
|
Hasandoost L, Alhalawani A, Rodriguez O, Rahimnejad Yazdi A, Zalzal P, Schemitsch EH, Waldman SD, Papini M, Towler MR. Calcium sulfate-containing glass polyalkenoate cement for revision total knee arthroplasty fixation. J Biomed Mater Res B Appl Biomater 2020; 108:3356-3369. [PMID: 32548909 DOI: 10.1002/jbm.b.34671] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2019] [Revised: 04/18/2020] [Accepted: 06/03/2020] [Indexed: 11/06/2022]
Abstract
Poly(methyl methacrylate) (PMMA) bone cement is used as a minor void filler in revision total knee arthroplasty (rTKA). The application of PMMA is indicated only for peripheral bone defects with less than 5 mm depth and that cover less than 50% of the bone surface. Treating bone defects with PMMA results in complications as a result of volumetric shrinkage, bone necrosis, and aseptic loosening. These concerns have driven the development of alternative bone cements. We report here on novel modified glass polyalkenoate cements (mGPCs) containing 1, 5 and 15 wt% calcium sulfate (CaSO4 ) and how the modified cements' properties compare to those of PMMA used in rTKA. CaSO4 is incorporated into the mGPC to improve both osteoconductivity and bioresorbability. The results confirm that the incorporation of CaSO4 into mGPCs decreases the setting time and increases release of therapeutic ions such as Ca2+ and Zn2+ over 30 days of maturation in deionized (DI) water. Moreover, the compressive strength for 5 and 15 wt% CaSO4 addition increased to over 30 MPa after 30 day maturation. Although the overall initial compressive strength of the mGPC (~ 30 MPa) is less than PMMA (~ 95 MPa), the compressive strength of mGPC is closer to that of cancellous bone (~ 1.2-7.8 MPa). CaSO4 addition did not affect biaxial flexural strength. Fourier transform infrared analysis indicated no cross-linking between CaSO4 and the GPC after 30 days. in vivo tests are required to determine the effects the modified GPCs as alternative on PMMA in rTKA.
Collapse
Affiliation(s)
- Leyla Hasandoost
- Faculty of Engineering and Architectural Science, Biomedical Engineering Program, Ryerson University, Toronto, Ontario, Canada.,Li Ka Shing Knowledge Institute, St. Michael's Hospital, Toronto, Ontario, Canada
| | - Adel Alhalawani
- Li Ka Shing Knowledge Institute, St. Michael's Hospital, Toronto, Ontario, Canada.,Department of Mechanical & Industrial Engineering, Ryerson University, Toronto, Ontario, Canada
| | - Omar Rodriguez
- Li Ka Shing Knowledge Institute, St. Michael's Hospital, Toronto, Ontario, Canada.,Department of Mechanical & Industrial Engineering, Ryerson University, Toronto, Ontario, Canada
| | - Alireza Rahimnejad Yazdi
- Li Ka Shing Knowledge Institute, St. Michael's Hospital, Toronto, Ontario, Canada.,Department of Mechanical & Industrial Engineering, Ryerson University, Toronto, Ontario, Canada
| | - Paul Zalzal
- Faculty of Health Sciences, Department of Surgery, McMaster University, Hamilton, Ontario, Canada.,Oakville Trafalgar Memorial Hospital, Oakville, Ontario, Canada
| | - Emil H Schemitsch
- Li Ka Shing Knowledge Institute, St. Michael's Hospital, Toronto, Ontario, Canada.,Department of Surgery, University of Western Ontario, London, Ontario, Canada
| | - Stephen D Waldman
- Faculty of Engineering and Architectural Science, Biomedical Engineering Program, Ryerson University, Toronto, Ontario, Canada.,Li Ka Shing Knowledge Institute, St. Michael's Hospital, Toronto, Ontario, Canada.,Department of Chemical Engineering, Ryerson University, Toronto, Ontario, Canada
| | - Marcello Papini
- Faculty of Engineering and Architectural Science, Biomedical Engineering Program, Ryerson University, Toronto, Ontario, Canada.,Department of Mechanical & Industrial Engineering, Ryerson University, Toronto, Ontario, Canada
| | - Mark R Towler
- Faculty of Engineering and Architectural Science, Biomedical Engineering Program, Ryerson University, Toronto, Ontario, Canada.,Li Ka Shing Knowledge Institute, St. Michael's Hospital, Toronto, Ontario, Canada.,Department of Mechanical & Industrial Engineering, Ryerson University, Toronto, Ontario, Canada
| |
Collapse
|
38
|
Tanweer N, Jouhar R, Ahmed MA. Influence of ultrasonic excitation on microhardness of glass ionomer cement. Technol Health Care 2020; 28:587-592. [PMID: 32538886 DOI: 10.3233/thc-191988] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND Numerous researchers have attempted to improve the mechanical properties of glass ionomer cement since 1972. In this study, ultrasonic curing treatment was introduced during the mixing of glass ionomer cement (GC Fuji IX) to facilitate intimate mixing, compaction and adaptation of residual glass particle which consequently improves densification of the material. OBJECTIVE To assess the influence of ultrasonic treatment on the microhardness of glass ionomer cement (GC Fuji IX) and compare it with the conventionally cured method. METHODS A total of 40 specimens (2 × 2 mm) were fabricated and equally divided into two groups: Group I (conventional curing method) and Group II (ultrasonically cured). For Group II, an ultrasonic scaler was used which provides energy to ensure proper mixing of material without leaving any air bubbles or unmixed particles. Vicker's hardness test was employed to generate the average microhardness values by making three indentations at different points on each specimen. Statistical Package for Social Sciences (SPSS) Version 17 was used, employing independent samples T test to compare the difference in microhardness values between two curing groups. RESULTS The average surface hardness value for conventional cured GIC was 62.21 ± 13.61 while ultrasonically cured GIC exhibited a higher mean microhardness value of 66.37 ± 12.83. Additionally, the average microhardness values produced by the two groups showed statistically significant differences (p value < 0.035). CONCLUSION Ultrasonic excitation treatment leads to intimate mixing and accelerated hardening of glass ionomer cement thereby enhancing its microhardness and reducing early weakness.
Collapse
Affiliation(s)
- Navara Tanweer
- Department of Science of Dental Materials, Sir Syed College of Medical Sciences, Karachi, Pakistan
| | - Rizwan Jouhar
- Department of Restorative Dentistry and Endodontics, College of Dentistry, King Faisal University, Al Ahsa, Saudi Arabia
| | - Muhammad Adeel Ahmed
- Department of Restorative Dentistry and Endodontics, College of Dentistry, King Faisal University, Al Ahsa, Saudi Arabia
| |
Collapse
|
39
|
Nicholson JW, Sidhu SK, Czarnecka B. Enhancing the Mechanical Properties of Glass-Ionomer Dental Cements: A Review. MATERIALS 2020; 13:ma13112510. [PMID: 32486416 PMCID: PMC7321445 DOI: 10.3390/ma13112510] [Citation(s) in RCA: 34] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 04/11/2020] [Revised: 05/20/2020] [Accepted: 05/26/2020] [Indexed: 11/18/2022]
Abstract
This paper reviews the strategies that have been reported in the literature to attempt to reinforce glass-ionomer dental cements, both conventional and resin-modified. These cements are widely used in current clinical practice, but their use is limited to regions where loading is not high. Reinforcement might extend these applications, particularly to the posterior dentition. A variety of strategies have been identified, including the use of fibres, nanoparticles, and larger particle additives. One problem revealed by the literature survey is the limited extent to which researchers have used International Standard test methods. This makes comparison of results very difficult. However, it does seem possible to draw conclusions from this substantial body of work and these are (1) that powders with conventional particle sizes do not reinforce glass-ionomer cements, (2) certain fibres and certain nanoparticles give distinct improvements in strength, and (3) in the case of the nanoparticles these improvements are associated with differences in the morphology of the cement matrix, in particular, a reduction in the porosity. Despite these improvements, none of the developments has yet been translated into clinical use.
Collapse
Affiliation(s)
- John W. Nicholson
- Dental Materials Unit, Bart’s and the London Institute of Dentistry, Queen Mary University of London, Mile End Road, London E1 4NS, UK
- Bluefield Centre for Biomaterials, 67-68 Hatton Garden, London EC1N 8JY, UK
- Correspondence:
| | - Sharanbir K. Sidhu
- Centre for Oral Bioengineering, Institute of Dentistry, Bart’s & The London School of Medicine and Dentistry, Queen Mary University of London, Turner Street, London E1 2AD, UK;
| | - Beata Czarnecka
- Department of Biomaterials and Experimental Dentistry, Poznań University of Medical Sciences, ul. Bukowska 70, 60-812 Poznań, Poland;
| |
Collapse
|
40
|
Ugurlu M. Effects of surface coating on the flexural strength of fluoridereleasing restorative materials after water aging for one year. Eur Oral Res 2020; 54:62-68. [PMID: 33474549 PMCID: PMC7787517 DOI: 10.26650/eor.20200042] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
Purpose: To evaluate the effects of surface coating and one-year water storage on the flexural
strength of fluoride-releasing restorative materials. Materials and methods: Forty specimens were prepared from each material; GCP Glass Fill (GCP), Amalgomer
CR (AHL), Zirconomer (Shofu), Fuji IX GP Capsule (GC), Beautifil II (Shofu), Estelite
Σ Quick (Tokuyama) and reliaFIL LC (AHL). The specimens were randomly divided
into two groups; surface coated with G-Coat Plus (GC) and uncoated. Each group
was subdivided into two groups stored in distilled water at 37◦C for 24 h and 1
year before testing (n=10). The flexural strength was evaluated using three-point
bending test according to the ISO 4049:2009 standard using a universal testing
machine. After flexural strength test, a cross-section of the coated specimens was
evaluated with scanning electron microscopy (SEM). Results: A significant increase was observed on the flexural strength of Amalgomer CR,
Zirconomer and Fuji IX GP after 24 h when G-Coat Plus was applied (p<0.05). This
significant increase was observed on the flexural strength of only Amalgomer CR
and Zirconomer after 1 year (p<0.05). The highest flexural strength was obtained
with Beautifil II, Estelite Σ Quick and reliaFIL LC after 24 h and 1 year (p<0.05). After
1 year, there was decrease on the flexural strength of the other materials except
Beautifil II, Estelite Σ Quick and reliaFIL LC. Conclusion: The resin coating improved the flexural strength of some glass ionomer-based
materials but the water aging decreased the same physical properties.
Collapse
Affiliation(s)
- Muhittin Ugurlu
- Süleyman Demirel University, Faculty of Dentistry,Department of Restorative Dentistry, IspartaTurkey
| |
Collapse
|
41
|
Kantovitz KR, Fernandes FP, Feitosa IV, Lazzarini MO, Denucci GC, Gomes OP, Giovani PA, Moreira KMS, Pecorari VGA, Borges AFS, Nociti FH, Basting RT, Lisboa-Filho PN, Puppin-Rontani RM. TiO2 nanotubes improve physico-mechanical properties of glass ionomer cement. Dent Mater 2020; 36:e85-e92. [DOI: 10.1016/j.dental.2020.01.018] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2019] [Revised: 11/27/2019] [Accepted: 01/14/2020] [Indexed: 10/25/2022]
|
42
|
MENEZES-SILVA R, OLIVEIRA BMBD, MAGALHÃES APR, BUENO LS, BORGES AFS, BAESSO ML, NAVARRO MFDL, NICHOLSON JW, SIDHU SK, PASCOTTO RC. Correlation between mechanical properties and stabilization time of chemical bonds in glass-ionomer cements. Braz Oral Res 2020; 34:e053. [DOI: 10.1590/1807-3107bor-2020.vol34.0053] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2019] [Accepted: 04/20/2020] [Indexed: 05/30/2023] Open
|
43
|
Brzović Rajić V, Ivanišević Malčić A, Bilge Kütük Z, Gurgan S, Jukić S, Miletić I. Compressive Strength of New Glass Ionomer Cement Technology based Restorative Materials after Thermocycling and Cyclic Loading. Acta Stomatol Croat 2019; 53:318-325. [PMID: 32099257 PMCID: PMC6993471 DOI: 10.15644/asc53/4/2] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
Objective The objective of the study was to compare compressive strengths of two glass ionomer-based materials, with and without a light-cured, nano-filled coating, after cyclic loading and thermocycling. Materials and methods To determine compressive strength of new restorative materials over a longer period of time, materials were analysed under simulated conditions where cyclic loading replicated masticatory loading and thermocycling simulated thermal oscillations in the oral cavity. Four groups of samples (n=7)—(1) Equia Fil (GC, Tokyo, Japan) uncoated; (2) Equia Fil coated with Equia Coat (GC, Tokyo, Japan); (3) Equia Forte Fil (GC, Tokyo, Japan) uncoated; and (4) Equia Forte Fil coated with Equia Forte coat (GC, Tokyo, Japan)—were subjected to cyclic loading (240,000 cycles) using a chewing simulator (MOD, Esetron Smart Robotechnologies, Ankara, Turkey). Results Compressive strength measurements were performed according to ISO 9917-1:2007, using the universal mechanical testing machine (Instron, Lloyd, UK). Scanning electron microscope (SEM) analysis was performed after thermocycling. There were no statistically significant differences between Equia Fil and Equia Forte Fil irrespective of the coating (p<0.05), but a trend of increasing compressive strength in the coated samples was observed. Conclusions Coating increases the compressive strength of Equia Fil and Equia Forte Fil, but not significantly.
Collapse
Affiliation(s)
- Valentina Brzović Rajić
- Department of Endodontics and Restorative Dentistry, School of Dental Medicine, University of Zagreb, Gundulićeva 5, 10000 Zagreb, Croatia
| | - Ana Ivanišević Malčić
- Department of Endodontics and Restorative Dentistry, School of Dental Medicine, University of Zagreb, Gundulićeva 5, 10000 Zagreb, Croatia
| | - Zeynep Bilge Kütük
- Department of Restorative Dentistry, School of Dentistry, Hacettepe University, Ankara 06100, Turkey
| | - Sevil Gurgan
- Department of Restorative Dentistry, School of Dentistry, Hacettepe University, Ankara 06100, Turkey
| | - Silvana Jukić
- Department of Endodontics and Restorative Dentistry, School of Dental Medicine, University of Zagreb, Gundulićeva 5, 10000 Zagreb, Croatia
| | - Ivana Miletić
- Department of Endodontics and Restorative Dentistry, School of Dental Medicine, University of Zagreb, Gundulićeva 5, 10000 Zagreb, Croatia
| |
Collapse
|
44
|
Mulder R, Anderson-Small C. Ion release of chitosan and nanodiamond modified glass ionomer restorative cements. Clin Cosmet Investig Dent 2019; 11:313-320. [PMID: 31686917 PMCID: PMC6737163 DOI: 10.2147/ccide.s220089] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2019] [Accepted: 07/31/2019] [Indexed: 11/23/2022] Open
Abstract
Purpose Ion release from glass ionomer restorative cements (GICs) plays an important role in GICs. The ion release from chitosan and nanodiamond-modified glass ionomers was assessed. Materials and methods Three GICs (Fuji IX, Ketac Universal and Riva Self Cure) were modified in the powder phase per weight by adding 5% or 10% of a commercially available chitosan powder (CH) or nanodiamond (ND) powder to the GICs. The specimens with dimensions 4 mm diameter and 6 mm height manufactured from the 15 GIC formulations were allowed to set for 1 hr and subsequently placed in neutral de-ionised water. The released ions were assessed using inductively coupled plasma-mass spectrometer (ICP-MS) to determine the elemental release. Additionally, three different disc-shaped specimens (3 mm in diameter and 1 mm thick) were constructed from each material for scanning electron microscopy (SEM) and energy dispersive X-ray spectrometry (SEM-EDS) microanalysis to establish an ion weight percentage. Results There were no significant differences in the ion release between the control materials for aluminium, silicon and strontium. The ion release from CH and most ND-modified GICs were significantly (p<0.00001) increased compared to the control materials. CH modifications significantly increased the ion release of aluminium, sodium, silicon and strontium for all three control materials (with the exception of the strontium release from Ketac Universal that was modified with 5% chitosan). Conclusion Ion release can be advantageous to tooth structure due to the interaction of chitosan with the GIC chemistry and moisture during maturation. Ion release up to five times greater than the control was noted for some ions.
Collapse
Affiliation(s)
- Riaan Mulder
- Paediatric Dentistry, The University of the Western Cape, Cape Town, South Africa
| | | |
Collapse
|
45
|
Emami Arjomand M, Eghlim MH, Jalalian SH, Mirzakhani M, Mahavi A. Effects of Aging on Compressive Strength of Two Resin-Reinforced Glass Ionomers: An In-Vitro Study. JOURNAL OF RESEARCH IN DENTAL AND MAXILLOFACIAL SCIENCES 2019. [DOI: 10.29252/jrdms.4.3.15] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/31/2022] Open
|
46
|
Jose A, Thomas A. A comparative evaluation of the microhardness of glass ionomer cements modified with chitosan and chlorhexidine: A 1-year in vitro study. J Int Oral Health 2019. [DOI: 10.4103/jioh.jioh_68_19] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
|