Yang S, Xue M, Xie T. Development of a Monte Carlo simulation platform for the systematic evaluation of photon-counting detector-based micro-CT. Phys Med 2024; 126:104824. [PMID: 39326287 DOI: 10.1016/j.ejmp.2024.104824] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/13/2024] [Revised: 08/26/2024] [Accepted: 09/22/2024] [Indexed: 09/28/2024] Open
Abstract
PURPOSE This study aimed to develop a photon-counting detector (PCD) based micro-CT simulation platform for assessing the performance of three different PCD sensor materials: cadmium telluride (CdTe), gallium arsenide (GaAs), and silicon (Si). The evaluation encompasses the components of primary and scatter signals, performance of imaging contrast agents, and detector efficiency. METHODS Simulations were performed using the Geant4 Monte Carlo toolkit, and a micro-PCD-CT system was meticulously modeled based on realistic geometric parameters. RESULTS The simulation can obtain HU values consistent with measured results for iodine and calcium hydroxyapatite contrast agents. The two major components of scatter signals for CdTe and GaAs based PCD are fluorescent X-ray photons and photoelectrons, whereas for Si, the components are photoelectrons and Compton electrons. Scattering counts of CdTe and GaAs sensors can be effectively reduced by using energy thresholds, whereas those of Si sensor are insensitive to the applied threshold. The optimal threshold values for CdTe and GaAs are 30 and 15 keV, respectively. For contrast agent imaging, GaAs exhibits enhanced sensitivity to low photon energies compared to CdTe, while it's contrast-to-noise ratio (CNR) values are slightly lower than those of CdTe at the same contrast agent concentration. Among the three sensor materials, Si has the lowest CNR and detector efficiency; CdTe exhibits the highest efficiency, except in low-energy ranges (< 45 keV), where GaAs has superior efficiency. CONCLUSIONS The proposed methods are expected to benefit PCD optimization and applications, including energy threshold selection, scattering correction, and may reduce the need for large-scale experiments.
Collapse
Affiliation(s)
- Shiyan Yang
- Institute of Radiation Medicine, Fudan University, 2094 Xietu Road, Shanghai 200032, China; Institute of Modern Physics, Fudan University, 220 Handan Road, Shanghai 200433, China
| | - Mengjia Xue
- Institute of Radiation Medicine, Fudan University, 2094 Xietu Road, Shanghai 200032, China
| | - Tianwu Xie
- Institute of Radiation Medicine, Fudan University, 2094 Xietu Road, Shanghai 200032, China.
| |
Collapse
|
2
|
Li M, Wu M, Pack J, Wu P, Yan P, De Man B, Wang A, Nieman K, Wang G. Coronary atherosclerotic plaque characterization with silicon-based photon-counting computed tomography (CT): A simulation-based feasibility study. Med Phys 2024. [PMID: 39321385 DOI: 10.1002/mp.17422] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2023] [Revised: 08/23/2024] [Accepted: 08/30/2024] [Indexed: 09/27/2024] Open
Abstract
BACKGROUND Recent photon-counting computed tomography (PCCT) development brings great opportunities for plaque characterization with much-improved spatial resolution and spectral imaging capability. While existing coronary plaque PCCT imaging results are based on CZT- or CdTe-materials detectors, deep-silicon photon-counting detectors offer unique performance characteristics and promise distinct imaging capabilities. PURPOSE This study aims to numerically investigate the feasibility of characterizing plaques with a deep-silicon PCCT scanner and to demonstrate its potential performance advantages over traditional CT scanners using energy-integrating detectors (EID). METHODS We conducted a systematic simulation study of a deep-silicon PCCT scanner using a newly developed digital plaque phantom with clinically relevant geometrical and chemical properties. Through qualitative and quantitative evaluations, this study investigates the effects of spatial resolution, noise, and motion artifacts on plaque imaging. RESULTS Noise-free simulations indicated that PCCT imaging could delineate the boundary of necrotic cores with a much finer resolution than EID-CT imaging, achieving a structural similarity index metric (SSIM) score of 0.970 and reducing the root mean squared error (RMSE) by two-thirds. Measuring necrotic core area errors were reduced from 91.5% to 24%, and fibrous cap thickness errors were reduced from 349.8% to 33.3%. In the presence of noise, the optimal reconstruction was achieved using 0.25 mm voxels and a soft reconstruction kernel, yielding the highest contrast-to-noise ratio (CNR) of 3.48 for necrotic core detection and the best image quality metrics among all choices. However, the ultrahigh resolution of PCCT increased sensitivity to motion artifacts, which could be mitigated by keeping residual motion amplitude below 0.4 mm. CONCLUSIONS The findings suggest that deep-silicon PCCT scanner can offer sufficient spatial resolution and tissue contrast for effective plaque characterization, potentially improving diagnostic accuracy in cardiovascular imaging, provided image noise and motion blur can be mitigated using advanced algorithms. This simulation study involves several simplifications, which may result in some idealized outcomes that do not directly translate to clinical practice. Further validation studies with physical scans are necessary and will be considered for future work.
Collapse
Affiliation(s)
- Mengzhou Li
- Biomedical Imaging Center, Center for Biotechnology and Interdisciplinary Research, Department of Biomedical Engineering, Rensselaer Polytechnic Institute, Troy, New York, USA
| | - Mingye Wu
- GE HealthCare Technology & Innovation Center, Niskayuna, New York, USA
| | - Jed Pack
- GE HealthCare Technology & Innovation Center, Niskayuna, New York, USA
| | - Pengwei Wu
- GE HealthCare Technology & Innovation Center, Niskayuna, New York, USA
| | - Pingkun Yan
- Biomedical Imaging Center, Center for Biotechnology and Interdisciplinary Research, Department of Biomedical Engineering, Rensselaer Polytechnic Institute, Troy, New York, USA
| | - Bruno De Man
- GE HealthCare Technology & Innovation Center, Niskayuna, New York, USA
| | - Adam Wang
- Department of Radiology, Stanford University, Stanford, California, USA
| | - Koen Nieman
- Department of Radiology, Stanford University, Stanford, California, USA
- Department of Medicine (Cardiovascular Medicine), Stanford University, Stanford, California, USA
| | - Ge Wang
- Biomedical Imaging Center, Center for Biotechnology and Interdisciplinary Research, Department of Biomedical Engineering, Rensselaer Polytechnic Institute, Troy, New York, USA
| |
Collapse
|
3
|
Xin L, Zhuo W, Liu Q, Xie T, Zaidi H. Triple-source saddle-curve cone-beam photon counting CT image reconstruction: A simulation study. Z Med Phys 2024; 34:408-418. [PMID: 36336554 PMCID: PMC11384087 DOI: 10.1016/j.zemedi.2022.10.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2022] [Revised: 09/18/2022] [Accepted: 10/05/2022] [Indexed: 11/06/2022]
Abstract
PURPOSE The most common detector material in the PC CT system, cannot achieve the best performance at a relatively higher photon flux rate. In the reconstruction view, the most commonly used filtered back projection, is not able to provide sufficient reconstructed image quality in spectral computed tomography (CT). Developing a triple-source saddle-curve cone-beam photon counting CT image reconstruction method can improve the temporal resolution. METHODS Triple-source saddle-curve cone-beam trajectory was rearranged into four trajectory sets for simulation and reconstruction. Projection images in different energy bins were simulated by forward projection and photon counting CT respond model simulation. After simulation, the object was reconstructed using Katsevich's theory after photon counts correction using the pseudo inverse of photon counting CT response matrix. The material decomposition can be performed based on images in different energy bins. RESULTS Root mean square error (RMSE) and structural similarity index (SSIM) are calculated to quantify the image quality of reconstruction images. Compared with FDK images, the RMSE for the triple-source image was improved by 27%, 21%, 14%, 8%, and 6% for the reconstrued image of 20-33, 33-47, 47-58, 58-69, 69-80 keV energy bin. The SSIM was improved by 1.031%, 0.665%, 0.396%, 0.235%, 0.174% for corresponding energy bin. The decomposition image based on corrected images shows improved RMSE and SSIM, each by 33.861% and 0.345%. SSIM of corrected decomposition image of iodine reaches 99.415% of the original image. CONCLUSIONS A new Triple-source saddle-curve cone-beam PC CT image reconstruction method was developed in this work. The exact reconstruction of the triple-source saddle-curve improved both the image quality and temporal resolution.
Collapse
Affiliation(s)
- Lin Xin
- Institute of Radiation Medicine, Fudan University, Shanghai, China
| | - Weihai Zhuo
- Institute of Radiation Medicine, Fudan University, Shanghai, China
| | - Qian Liu
- School of Biomedical Engineering, Hainan University, Haikou, China.
| | - Tianwu Xie
- Institute of Radiation Medicine, Fudan University, Shanghai, China; Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, Geneva, Switzerland.
| | - Habib Zaidi
- Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, Geneva, Switzerland; Geneva Neuroscience Center, Geneva University, Geneva, Switzerland; Department of Nuclear Medicine and Molecular Imaging, University of Groningen, University Medical Center Groningen, Groningen, the Netherlands; Department of Nuclear Medicine, University of Southern Denmark, Odense, Denmark
| |
Collapse
|
4
|
Grönberg F, Yin Z, Maltz JS, Pelc NJ, Persson M. The effects of intra-detector Compton scatter on low-frequency DQE for photon-counting CT using edge-on-irradiated silicon detectors. Med Phys 2024; 51:4948-4969. [PMID: 38753884 DOI: 10.1002/mp.17122] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2024] [Revised: 04/01/2024] [Accepted: 04/23/2024] [Indexed: 05/18/2024] Open
Abstract
BACKGROUND Edge-on-irradiated silicon detectors are currently being investigated for use in full-body photon-counting computed tomography (CT) applications. The low atomic number of silicon leads to a significant number of incident photons being Compton scattered in the detector, depositing a part of their energy and potentially being counted multiple times. Even though the physics of Compton scatter is well established, the effects of Compton interactions in the detector on image quality for an edge-on-irradiated silicon detector have still not been thoroughly investigated. PURPOSE To investigate and explain effects of Compton scatter on low-frequency detective quantum efficiency (DQE) for photon-counting CT using edge-on-irradiated silicon detectors. METHODS We extend an existing Monte Carlo model of an edge-on-irradiated silicon detector with 60 mm active absorption depth, previously used to evaluate spatial-frequency-based performance, to develop projection and image domain performance metrics for pure density and pure spectral imaging tasks with 30 and 40 cm water backgrounds. We show that the lowest energy threshold of the detector can be used as an effective discriminator of primary counts and cross-talk caused by Compton scatter. We study the developed metrics as functions of the lowest threshold energy for root-mean-square electronic noise levels of 0.8, 1.6, and 3.2 keV, where the intermediate level 1.6 keV corresponds to the noise level previously measured on a single sensor element in isolation. We also compare the performance of a modeled detector with 8, 4, and 2 optimized energy bins to a detector with 1-keV-wide bins. RESULTS In terms of low-frequency DQE for density imaging, there is a tradeoff between using a threshold low enough to capture Compton interactions and avoiding electronic noise counts. For 30 cm water phantom, 4 energy bins, and a root-mean-square electronic noise of 0.8, 1.6, and 3.2 keV, it is optimal to put the lowest energy threshold at 3, 6, and 1 keV, which gives optimal projection-domain DQEs of 0.64, 0.59, and 0.52, respectively. Low-frequency DQE for spectral imaging also benefits from measuring Compton interactions with respective optimal thresholds of 12, 12, and 13 keV. No large dependence on background thickness was observed. For the intermediate noise level (1.6 keV), increasing the lowest threshold from 5 to 35 keV increases the variance in a iodine basis image by 60%-62% (30 cm phantom) and 67%-69% (40 cm phantom), with 8 bins. Both spectral and density DQE are adversely affected by increasing the electronic noise level. Image-domain DQE exhibits similar qualitative behavior as projection-domain DQE. CONCLUSIONS Compton interactions contribute significantly to the density imaging performance of edge-on-irradiated silicon detectors. With the studied detector topology, the benefit of counting primary Compton interactions outweighs the penalty of multiple counting at all lowest threshold energies. Compton interactions also contribute significantly to the spectral imaging performance for measured energies above 10 keV.
Collapse
Affiliation(s)
- Fredrik Grönberg
- Department of Physics, KTH Royal Institute of Technology, AlbaNova University Center, Stockholm, Sweden
- GE HealthCare, Stockholm, Sweden
| | | | | | - Norbert J Pelc
- Department of Radiology, Stanford University, Stanford, California, USA
| | - Mats Persson
- Department of Physics, KTH Royal Institute of Technology, AlbaNova University Center, Stockholm, Sweden
- MedTechLabs, Karolinska University Hospital, Stockholm, Sweden
| |
Collapse
|
5
|
Sharma S, Pal D, Abadi E, Segars P, Hsieh J, Samei E. Deep silicon photon-counting CT: A first simulation-based study for assessing perceptual benefits across diverse anatomies. Eur J Radiol 2024; 171:111279. [PMID: 38194843 PMCID: PMC10922475 DOI: 10.1016/j.ejrad.2023.111279] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2023] [Revised: 11/26/2023] [Accepted: 12/20/2023] [Indexed: 01/11/2024]
Abstract
OBJECTIVES To assess perceptual benefits provided by the improved spatial resolution and noise performance of deep silicon photon-counting CT (Si-PCCT) over conventional energy-integrating CT (ECT) using polychromatic images for various clinical tasks and anatomical regions. MATERIALS AND METHODS Anthropomorphic, computational models were developed for lungs, liver, inner ear, and head-and-neck (H&N) anatomies. These regions included specific abnormalities such as lesions in the lungs and liver, and calcified plaques in the carotid arteries. The anatomical models were imaged using a scanner-specific CT simulation platform (DukeSim) modeling a Si-PCCT prototype and a conventional ECT system at matched dose levels. The simulated polychromatic projections were reconstructed with matched in-plane resolutions using manufacturer-specific software. The reconstructed pairs of images were scored by radiologists to gauge the task-specific perceptual benefits provided by Si-PCCT compared to ECT based on visualization of anatomical and image quality features. The scores were standardized as z-scores for minimizing inter-observer variability and compared between the systems for evidence of statistically significant improvement (one-sided Wilcoxon rank-sum test with a significance level of 0.05) in perceptual performance for Si-PCCT. RESULTS Si-PCCT offered favorable image quality and improved visualization capabilities, leading to mean improvements in task-specific perceptual performance over ECT for most tasks. The improvements for Si-PCCT were statistically significant for the visualization of lung lesion (0.08 ± 0.89 vs. 0.90 ± 0.48), liver lesion (-0.64 ± 0.37 vs. 0.95 ± 0.55), and soft tissue structures (-0.47 ± 0.90 vs. 0.33 ± 1.24) and cochlea (-0.47 ± 0.80 vs. 0.38 ± 0.62) in inner ear. CONCLUSIONS Si-PCCT exhibited mean improvements in task-specific perceptual performance over ECT for most clinical tasks considered in this study, with statistically significant improvement for 6/20 tasks. The perceptual performance of Si-PCCT is expected to improve further with availability of spectral information and reconstruction kernels optimized for high resolution provided by smaller pixel size of Si-PCCT. The outcomes of this study indicate the positive potential of Si-PCCT for benefiting routine clinical practice through improved image quality and visualization capabilities.
Collapse
Affiliation(s)
- Shobhit Sharma
- Center for Virtual Imaging Trials and Carl E. Ravin Advanced Imaging Laboratories, 2424 Erwin Rd, Suite 302, Durham, NC 27705, USA; Department of Physics, Duke University, Science Drive, Durham, NC 27708, USA
| | - Debashish Pal
- GE Healthcare, 3000 N Grandview Blvd, Waukesha, WI 53188, USA
| | - Ehsan Abadi
- Center for Virtual Imaging Trials and Carl E. Ravin Advanced Imaging Laboratories, 2424 Erwin Rd, Suite 302, Durham, NC 27705, USA; Department of Radiology, Duke University, 2301 Erwin Rd, Durham, NC 27705, USA.
| | - Paul Segars
- Center for Virtual Imaging Trials and Carl E. Ravin Advanced Imaging Laboratories, 2424 Erwin Rd, Suite 302, Durham, NC 27705, USA; Department of Radiology, Duke University, 2301 Erwin Rd, Durham, NC 27705, USA
| | - Jiang Hsieh
- GE Healthcare, 3000 N Grandview Blvd, Waukesha, WI 53188, USA
| | - Ehsan Samei
- Center for Virtual Imaging Trials and Carl E. Ravin Advanced Imaging Laboratories, 2424 Erwin Rd, Suite 302, Durham, NC 27705, USA; Department of Physics, Duke University, Science Drive, Durham, NC 27708, USA; Department of Radiology, Duke University, 2301 Erwin Rd, Durham, NC 27705, USA
| |
Collapse
|
6
|
Zhan X, Zhang R, Niu X, Hein I, Budden B, Wu S, Markov N, Clarke C, Qiang Y, Taguchi H, Nomura K, Muramatsu Y, Yu Z, Kobayashi T, Thompson R, Miyazaki H, Nakai H. Comprehensive evaluations of a prototype full field-of-view photon counting CT system through phantom studies. Phys Med Biol 2023; 68:175007. [PMID: 37506710 DOI: 10.1088/1361-6560/acebb3] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2023] [Accepted: 07/28/2023] [Indexed: 07/30/2023]
Abstract
Objective. Photon counting CT (PCCT) has been a research focus in the last two decades. Recent studies and advancements have demonstrated that systems using semiconductor-based photon counting detectors (PCDs) have the potential to provide better contrast, noise and spatial resolution performance compared to conventional scintillator-based systems. With multi-energy threshold detection, PCD can simultaneously provide the photon energy measurement and enable material decomposition for spectral imaging. In this work, we report a performance evaluation of our first CdZnTe-based prototype full-size PCCT system through various phantom imaging studies.Approach.This prototype system supports a 500 mm scan field-of-view and 10 mmz-coverage at isocenter. Phantom scans were acquired using 120 kVp from 50 to 400 mAs to assess the imaging performance on: CT number accuracy, uniformity, noise, spatial resolution, material differentiation and quantification.Main results.Both qualitative and quantitative evaluations show that PCCT, under the tested conditions, has superior imaging performance with lower noise and improved spatial resolution compared to conventional energy integrating detector (EID)-CT. Using projection domain material decomposition approach with multiple energy bin measurements, PCCT virtual monoenergetic images have lower noise, and good accuracy in quantifying iodine and calcium concentrations. These results lead to increased contrast-to-noise ratio (CNR) for both high and low contrast study objects compared to EID-CT at matched dose and spatial resolution. PCCT can also generate super-high resolution images using much smaller detector pixel size than EID-CT and greatly improve image spatial resolution.Significance.Improved spatial resolution and quantification accuracy with reduced image noise of the PCCT images can potentially lead to better diagnosis at reduced radiation dose compared to conventional EID-CT. Increased CNR achieved by PCCT suggests potential reduction in iodine contrast media load, resulting in better patient safety and reduced cost.
Collapse
Affiliation(s)
- Xiaohui Zhan
- Canon Medical Research USA, Inc., 706 Deerpath Drive, Vernon Hills, IL 60061, United States of America
| | - Ruoqiao Zhang
- Canon Medical Research USA, Inc., 706 Deerpath Drive, Vernon Hills, IL 60061, United States of America
| | - Xiaofeng Niu
- Canon Medical Research USA, Inc., 706 Deerpath Drive, Vernon Hills, IL 60061, United States of America
| | - Ilmar Hein
- Canon Medical Research USA, Inc., 706 Deerpath Drive, Vernon Hills, IL 60061, United States of America
| | - Brent Budden
- Canon Medical Research USA, Inc., 706 Deerpath Drive, Vernon Hills, IL 60061, United States of America
| | - Shuoxing Wu
- Canon Medical Research USA, Inc., 706 Deerpath Drive, Vernon Hills, IL 60061, United States of America
| | - Nicolay Markov
- Canon Medical Research USA, Inc., 706 Deerpath Drive, Vernon Hills, IL 60061, United States of America
| | - Cameron Clarke
- Canon Medical Research USA, Inc., 706 Deerpath Drive, Vernon Hills, IL 60061, United States of America
| | - Yi Qiang
- Canon Medical Research USA, Inc., 706 Deerpath Drive, Vernon Hills, IL 60061, United States of America
| | - Hiroki Taguchi
- Canon Medical System Corporation, Otawara, Tochigi, Japan
| | - Keiichi Nomura
- National Cancer Centre Hospital East, 6-5-1 Kashiwanoha, Kashiwa, Japan
| | | | - Zhou Yu
- Canon Medical Research USA, Inc., 706 Deerpath Drive, Vernon Hills, IL 60061, United States of America
| | | | - Richard Thompson
- Canon Medical Research USA, Inc., 706 Deerpath Drive, Vernon Hills, IL 60061, United States of America
| | | | - Hiroaki Nakai
- Canon Medical System Corporation, Otawara, Tochigi, Japan
| |
Collapse
|
7
|
Stein T, Rau A, Russe MF, Arnold P, Faby S, Ulzheimer S, Weis M, Froelich MF, Overhoff D, Horger M, Hagen F, Bongers M, Nikolaou K, Schönberg SO, Bamberg F, Weiß J. Photon-Counting Computed Tomography - Basic Principles, Potenzial Benefits, and Initial Clinical Experience. ROFO-FORTSCHR RONTG 2023; 195:691-698. [PMID: 36863367 DOI: 10.1055/a-2018-3396] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/04/2023]
Abstract
BACKGROUND Photon-counting computed tomography (PCCT) is a promising new technology with the potential to fundamentally change today's workflows in the daily routine and to provide new quantitative imaging information to improve clinical decision-making and patient management. METHOD The content of this review is based on an unrestricted literature search on PubMed and Google Scholar using the search terms "Photon-Counting CT", "Photon-Counting detector", "spectral CT", "Computed Tomography" as well as on the authors' experience. RESULTS The fundamental difference with respect to the currently established energy-integrating CT detectors is that PCCT allows counting of every single photon at the detector level. Based on the identified literature, PCCT phantom measurements and initial clinical studies have demonstrated that the new technology allows improved spatial resolution, reduced image noise, and new possibilities for advanced quantitative image postprocessing. CONCLUSION For clinical practice, the potential benefits include fewer beam hardening artifacts, radiation dose reduction, and the use of new contrast agents. In this review, we will discuss basic technical principles and potential clinical benefits and demonstrate first clinical use cases. KEY POINTS · Photon-counting computed tomography (PCCT) has been implemented in the clinical routine. · Compared to energy-integrating detector CT, PCCT allows the reduction of electronic image noise. · PCCT provides increased spatial resolution and a higher contrast-to-noise ratio. · The novel detector technology allows the quantification of spectral information. CITATION FORMAT · Stein T, Rau A, Russe MF et al. Photon-Counting Computed Tomography - Basic Principles, Potenzial Benefits, and Initial Clinical Experience. Fortschr Röntgenstr 2023; 195: 691 - 698.
Collapse
Affiliation(s)
- Thomas Stein
- Department of Diagnostic and Interventional Radiology, Medical Center-University of Freiburg, Germany
| | - Alexander Rau
- Department of Diagnostic and Interventional Radiology, Medical Center-University of Freiburg, Germany
| | - Maximilian Frederik Russe
- Department of Diagnostic and Interventional Radiology, Medical Center-University of Freiburg, Germany
| | - Philipp Arnold
- Department of Diagnostic and Interventional Radiology, Medical Center-University of Freiburg, Germany
| | - Sebastian Faby
- Computed Tomography, Siemens Healthcare GmbH, Forchheim, Germany
| | - Stefan Ulzheimer
- Computed Tomography, Siemens Healthcare GmbH, Forchheim, Germany
| | - Meike Weis
- Department of Radiology and Nuclear Medicine, University Medical Centre Mannheim, Germany
| | - Matthias F Froelich
- Department of Radiology and Nuclear Medicine, University Medical Centre Mannheim, Germany
| | - Daniel Overhoff
- Department of Radiology and Nuclear Medicine, University Medical Centre Mannheim, Germany
| | - Marius Horger
- Department of Radiology, University Hospitals Tübingen, Germany
| | - Florian Hagen
- Department of Radiology, University Hospitals Tübingen, Germany
| | - Malte Bongers
- Department of Radiology, University Hospitals Tübingen, Germany
| | | | - Stefan O Schönberg
- Department of Radiology and Nuclear Medicine, University Medical Centre Mannheim, Germany
| | - Fabian Bamberg
- Department of Diagnostic and Interventional Radiology, Medical Center-University of Freiburg, Germany
| | - Jakob Weiß
- Department of Diagnostic and Interventional Radiology, Medical Center-University of Freiburg, Germany
| |
Collapse
|
8
|
Grigoriev M, Zolotov D, Ingacheva A, Buzmakov A, Dyachkova I, Asadchikov V, Chukalina M. Crystal Analyzer Based Multispectral Microtomography Using CCD-Sensor. SENSORS (BASEL, SWITZERLAND) 2023; 23:6389. [PMID: 37514683 PMCID: PMC10386214 DOI: 10.3390/s23146389] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/09/2023] [Revised: 07/06/2023] [Accepted: 07/12/2023] [Indexed: 07/30/2023]
Abstract
To solve the problems of spectral tomography, an X-ray optical scheme was proposed, using a crystal analyzer in Laue geometry between the sample and the detector, which allowed for the selection of predetermined pairs of wavelengths from the incident polychromatic radiation to obtain projection images. On a laboratory X-ray microtomography setup, an experiment was carried out for the first time where a mixture of micro-granules of sodium chloride NaCl, silver behenate AgC22H43O2, and lithium niobate LiNbO3 was used as a test sample to identify their spatial arrangement. The elements were chosen based on the presence of absorption edges in two of the elements in the energy range of the polychromatic spectrum of the probing radiation. The method of projection distortion correction was used to preprocess the obtained projections. To interpret the obtained reconstruction results, the segmentation method based on the analysis of joint histograms was used. This allowed us to identify each of the three substances. To compare the results obtained, additional "reference" tomographic measurements were performed: one in polychromatic and two in monochromatic (MoKα-, MoKβ-lines) modes. It took three times less time for the tomographic experiment with the crystal analyzer, while the reconstruction accuracy was comparable to that of the "reference" tomography.
Collapse
Affiliation(s)
- Maxim Grigoriev
- Institute of Microelectronics Technology and High Purity Materials RAS, Osipyan Str., 6, 142432 Chernogolovka, Russia
| | - Denis Zolotov
- FSRC "Crystallography and Photonics" RAS, Leninskiy Prospekt 59, 119333 Moscow, Russia
| | - Anastasia Ingacheva
- Smart Engines Service LLC, 60-Letiya Oktyabrya Avenue, 9, 117312 Moscow, Russia
- Institute for Information Transmission Problems (Kharkevich Institute) RAS, Bolshoy Karetny Lane, 19, 127051 Moscow, Russia
| | - Alexey Buzmakov
- FSRC "Crystallography and Photonics" RAS, Leninskiy Prospekt 59, 119333 Moscow, Russia
| | - Irina Dyachkova
- FSRC "Crystallography and Photonics" RAS, Leninskiy Prospekt 59, 119333 Moscow, Russia
| | - Victor Asadchikov
- FSRC "Crystallography and Photonics" RAS, Leninskiy Prospekt 59, 119333 Moscow, Russia
| | - Marina Chukalina
- Smart Engines Service LLC, 60-Letiya Oktyabrya Avenue, 9, 117312 Moscow, Russia
- Institute for Information Transmission Problems (Kharkevich Institute) RAS, Bolshoy Karetny Lane, 19, 127051 Moscow, Russia
| |
Collapse
|
9
|
Agostini A, Borgheresi A, Mariotti F, Ottaviani L, Carotti M, Valenti M, Giovagnoni A. New frontiers in oncological imaging with Computed Tomography: from morphology to function. Semin Ultrasound CT MR 2023; 44:214-227. [PMID: 37245886 DOI: 10.1053/j.sult.2023.03.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/03/2023]
|
10
|
An introduction to photon-counting detector CT (PCD CT) for radiologists. Jpn J Radiol 2023; 41:266-282. [PMID: 36255601 PMCID: PMC9974724 DOI: 10.1007/s11604-022-01350-6] [Citation(s) in RCA: 10] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2022] [Accepted: 10/01/2022] [Indexed: 10/24/2022]
Abstract
The basic performance of photon-counting detector computed tomography (PCD CT) is superior to conventional CT (energy-integrating detector CT: EID CT) because its spatial- and contrast resolution of soft tissues is higher, and artifacts are reduced. Because the X-ray photon energy separation is better with PCD CT than conventional EID-based dual-energy CT, it has the potential to improve virtual monochromatic- and virtual non-contrast images, material decomposition including quantification of the iodine distribution, and K-edge imaging. Therefore, its clinical applicability may be increased. Although the image quality of PCD CT scans is superior to that of EID CT currently, further improvement may be possible. The introduction of iterative image reconstruction and reconstruction with deep convolutional neural networks will be useful.
Collapse
|
11
|
Ran P, Yang L, Jiang T, Xu X, Hui J, Su Y, Kuang C, Liu X, Yang YM. Multispectral Large-Panel X-ray Imaging Enabled by Stacked Metal Halide Scintillators. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2022; 34:e2205458. [PMID: 35963008 DOI: 10.1002/adma.202205458] [Citation(s) in RCA: 15] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/15/2022] [Revised: 07/28/2022] [Indexed: 06/15/2023]
Abstract
Conventional energy-integration black-white X-ray imaging lacks the spectral information of X-ray photons. Although X-ray spectra (energy) can be distinguished by the photon-counting technique typically with CdZnTe detectors, it is very challenging to be applied to large-area flat-panel X-ray imaging (FPXI). Herein, multilayer stacked scintillators of different X-ray absorption capabilities and scintillation spectra are designed; in this scenario, the X-ray energy can be discriminated by detecting the emission spectra of each scintillator; therefore, multispectral X-ray imaging can be easily obtained by color or multispectral visible-light camera in a single shot of X-rays. To verify this idea, stacked multilayer scintillators based on several emerging metal halides are fabricated in a cost-effective and scalable solution process, and proof-of-concept multispectral (or multi-energy) FPXI are experimentally demonstrated. The dual-energy X-ray image of a "bone-muscle" model clearly shows the details that are invisible in conventional energy-integration FPXI. By stacking four layers of specifically designed multilayer scintillators with appropriate thicknesses, a prototype FPXI with four energy channels is realized, proving its extendibility to multispectral or even hyperspectral X-ray imaging. This study provides a facile and effective strategy to realize multispectral large-area flat-panel X-ray imaging.
Collapse
Affiliation(s)
- Peng Ran
- State Key Laboratory of Modern Optical Instrumentation, College of Optical Science and Engineering, International Research Center for Advanced Photonics, Zhejiang University, Hangzhou, Zhejiang, 310027, China
| | - Lurong Yang
- State Key Laboratory of Modern Optical Instrumentation, College of Optical Science and Engineering, International Research Center for Advanced Photonics, Zhejiang University, Hangzhou, Zhejiang, 310027, China
| | - Tingming Jiang
- State Key Laboratory of Modern Optical Instrumentation, College of Optical Science and Engineering, International Research Center for Advanced Photonics, Zhejiang University, Hangzhou, Zhejiang, 310027, China
| | - Xuehui Xu
- State Key Laboratory of Modern Optical Instrumentation, College of Optical Science and Engineering, International Research Center for Advanced Photonics, Zhejiang University, Hangzhou, Zhejiang, 310027, China
| | - Juan Hui
- State Key Laboratory of Modern Optical Instrumentation, College of Optical Science and Engineering, International Research Center for Advanced Photonics, Zhejiang University, Hangzhou, Zhejiang, 310027, China
| | - Yirong Su
- State Key Laboratory of Modern Optical Instrumentation, College of Optical Science and Engineering, International Research Center for Advanced Photonics, Zhejiang University, Hangzhou, Zhejiang, 310027, China
| | - Cuifang Kuang
- State Key Laboratory of Modern Optical Instrumentation, College of Optical Science and Engineering, International Research Center for Advanced Photonics, Zhejiang University, Hangzhou, Zhejiang, 310027, China
| | - Xu Liu
- State Key Laboratory of Modern Optical Instrumentation, College of Optical Science and Engineering, International Research Center for Advanced Photonics, Zhejiang University, Hangzhou, Zhejiang, 310027, China
| | - Yang Michael Yang
- State Key Laboratory of Modern Optical Instrumentation, College of Optical Science and Engineering, International Research Center for Advanced Photonics, Zhejiang University, Hangzhou, Zhejiang, 310027, China
- Intelligent Optics & Photonics Research Center Jiaxing Institute of Zhejiang University, Jiaxing, Zhejiang, 314041, China
| |
Collapse
|
12
|
Fujiwara D, Shimomura T, Zhao W, Li KW, Haga A, Geng LS. Virtual computed-tomography system for deep-learning-based material decomposition. Phys Med Biol 2022; 67. [DOI: 10.1088/1361-6560/ac7bcd] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2022] [Accepted: 06/23/2022] [Indexed: 11/12/2022]
Abstract
Abstract
Objective. Material decomposition (MD) evaluates the elemental composition of human tissues and organs via computed tomography (CT) and is indispensable in correlating anatomical images with functional ones. A major issue in MD is inaccurate elemental information about the real human body. To overcome this problem, we developed a virtual CT system model, by which various reconstructed images can be generated based on ICRP110 human phantoms with information about six major elements (H, C, N, O, P, and Ca). Approach. We generated CT datasets labelled with accurate elemental information using the proposed generative CT model and trained a deep learning (DL)-based model to estimate the material distribution with the ICRP110 based human phantom as well as the digital Shepp–Logan phantom. The accuracy in quad-, dual-, and single-energy CT cases was investigated. The influence of beam-hardening artefacts, noise, and spectrum variations were analysed with testing datasets including elemental density and anatomical shape variations. Main results. The results indicated that this DL approach can realise precise MD, even with single-energy CT images. Moreover, noise, beam-hardening artefacts, and spectrum variations were shown to have minimal impact on the MD. Significance. Present results suggest that the difficulty to prepare a large CT database can be solved by introducing the virtual CT system and the proposed technique can be applied to clinical radiodiagnosis and radiotherapy.
Collapse
|
13
|
Higashigaito K, Euler A, Eberhard M, Flohr TG, Schmidt B, Alkadhi H. Contrast-Enhanced Abdominal CT with Clinical Photon-Counting Detector CT: Assessment of Image Quality and Comparison with Energy-Integrating Detector CT. Acad Radiol 2022; 29:689-697. [PMID: 34389259 DOI: 10.1016/j.acra.2021.06.018] [Citation(s) in RCA: 57] [Impact Index Per Article: 28.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2021] [Revised: 06/28/2021] [Accepted: 06/30/2021] [Indexed: 02/07/2023]
Abstract
RATIONALE AND OBJECTIVES To determine quantitative and qualitative image quality of contrast-enhanced abdominal photon-counting detector CT (PCD-CT) compared to energy-integrating detector CT (EID-CT) in the same patients. MATERIAL AND METHODS Thirty-nine patients (mean age 63 ± 10 years, 10 females, mean BMI 26.0 ± 5.7 kg/m2) were retrospectively included who underwent clinically indicated, contrast-enhanced abdominal CT in portal-venous phase with first-generation dual-source PCD-CT and who underwent previous abdominal CT with EID-CT. For both scan, same contrast media protocol was used. PCD-CT was performed in QuantumPlus mode (obtaining full spectral information) at 120kVp. EID-CT was performed using automated tube voltage selection (reference tube voltage 100kVp). In PCD-CT, virtual monoenergetic images (VMI) were reconstructed in 10keV intervals (40-90 keV). Tube current-time product in PCD-CT was modified in each patient to obtain same volume CT-dose-index (CTDIvol) as with EID-CT. Attenuation of organs and vascular structures were measured, noise quantified, and contrast-to-noise ratio (CNR) calculated. Two independent, blinded radiologists assessed subjective image quality using a 5-point Likert scale (overall image quality, image noise, contrast, and liver lesion conspicuity). RESULTS Median time interval between the scan was 12 months. BMI (p = 0.905) and CTDIvol (p = 0.984) were similar between scans. CNRparenchymal and CNRvascular of VMI from PCD-CT at 40 and 50keV were significantly higher than EID-CT (all, p < 0.05). Overall, inter-reader agreement for all subjective image quality readings was substantial (Krippendorff's alpha = 0.773). Overall image quality of VMI was rated similar at 50 and 60 keV compared to EID-CT (all, p > 0.05). Subjective image noise was significantly higher at 40-50 keV, contrast significantly higher at 40-60 keV (all, p < 0.05). Lesion conspicuity was rated similar on all images. CONCLUSION Our intra-individual analysis of abdominal PCD-CT indicates that VMI at 50 keV shows significantly higher CNR at similar subjective image quality as compared to EID-CT at identical radiation dose.
Collapse
|
14
|
Jumanazarov D, Koo J, Poulsen HF, Olsen UL, Iovea M. Significance of the spectral correction of photon counting detector response in material classification from spectral x-ray CT. J Med Imaging (Bellingham) 2022; 9:034504. [PMID: 35789704 DOI: 10.1117/1.jmi.9.3.034504] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2021] [Accepted: 06/16/2022] [Indexed: 11/14/2022] Open
Abstract
Purpose: Photon counting imaging detectors (PCD) has paved the way for spectral x-ray computed tomography (spectral CT), which simultaneously measures a sample's linear attenuation coefficient (LAC) at multiple energies. However, cadmium telluride (CdTe)-based PCDs working under high flux suffer from detector effects, such as charge sharing and photon pileup. These effects result in the severe spectral distortions of the measured spectra and significant deviation of the extracted LACs from the reference attenuation curve. We analyze the influence of the spectral distortion correction on material classification performance. Approach: We employ a spectral correction algorithm to reduce the primary spectral distortions. We use a method for material classification that measures system-independent material properties, such as electron density, ρ e , and effective atomic number, Z eff . These parameters are extracted from the LACs using attenuation decomposition and are independent of the scanner specification. The classification performance with the raw and corrected data is tested on different numbers of energy bins and projections and different radiation dose levels. We use experimental data with a broad range of materials in the range of 6 ≤ Z eff ≤ 15 , acquired with a custom laboratory instrument for spectral CT. Results: We show that using the spectral correction leads to an accuracy increase of 1.6 and 3.8 times in estimating ρ e and Z eff , respectively, when the image reconstruction is performed from only 12 projections and the 15 energy bins approach is used. Conclusions: The correction algorithm accurately reconstructs the measured attenuation curve and thus gives better classification performance.
Collapse
Affiliation(s)
- Doniyor Jumanazarov
- Technical University of Denmark, DTU Physics, Lyngby, Denmark.,ACCENT PRO 2000 s.r.l. (AP2K), Bucharest, Romania
| | - Jakeoung Koo
- Technical University of Denmark, DTU Compute, Lyngby, Denmark
| | | | - Ulrik L Olsen
- Technical University of Denmark, DTU Physics, Lyngby, Denmark
| | - Mihai Iovea
- ACCENT PRO 2000 s.r.l. (AP2K), Bucharest, Romania
| |
Collapse
|
15
|
Spectral Photon-Counting CT Technology in Chest Imaging. J Clin Med 2021; 10:jcm10245757. [PMID: 34945053 PMCID: PMC8704215 DOI: 10.3390/jcm10245757] [Citation(s) in RCA: 39] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2021] [Revised: 11/30/2021] [Accepted: 12/02/2021] [Indexed: 12/17/2022] Open
Abstract
The X-ray imaging field is currently undergoing a period of rapid technological innovation in diagnostic imaging equipment. An important recent development is the advent of new X-ray detectors, i.e., photon-counting detectors (PCD), which have been introduced in recent clinical prototype systems, called PCD computed tomography (PCD-CT) or photon-counting CT (PCCT) or spectral photon-counting CT (SPCCT) systems. PCD allows a pixel up to 200 microns pixels at iso-center, which is much smaller than that can be obtained with conventional energy integrating detectors (EID). PCDs have also a higher dose efficiency than EID mainly because of electronic noise suppression. In addition, the energy-resolving capabilities of these detectors allow generating spectral basis imaging, such as the mono-energetic images or the water/iodine material images as well as the K-edge imaging of a contrast agent based on atoms of high atomic number. In recent years, studies have therefore been conducted to determine the potential of PCD-CT as an alternative to conventional CT for chest imaging.
Collapse
|
16
|
Ji X, Feng M, Treb K, Zhang R, Schafer S, Li K. Development of an Integrated C-Arm Interventional Imaging System With a Strip Photon Counting Detector and a Flat Panel Detector. IEEE TRANSACTIONS ON MEDICAL IMAGING 2021; 40:3674-3685. [PMID: 34232872 DOI: 10.1109/tmi.2021.3095419] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Modern interventional x-ray systems are often equipped with flat-panel detector-based cone-beam CT (FPD-CBCT) to provide tomographic, volumetric, and high spatial resolution imaging of interventional devices, iodinated vessels, and other objects. The purpose of this work was to bring an interchangeable strip photon-counting detector (PCD) to C-arm systems to supplement (instead of retiring) the existing FPD-CBCT with a high quality, spectral, and affordable PCD-CT imaging option. With minimal modification to the existing C-arm, a 51×0.6 cm2 PCD with a 0.75 mm CdTe layer, two energy thresholds, and 0.1 mm pixels was integrated with a Siemens Artis Zee interventional imaging system. The PCD can be translated in and out of the field-of-view to allow the system to switch between FPD and PCD-CT imaging modes. A dedicated phantom and a new algorithm were developed to calibrate the projection geometry of the narrow-beam PCD-CT system and correct the gantry wobbling-induced geometric distortion artifacts. In addition, a detector response calibration procedure was performed for each PCD pixel using materials with known radiological pathlengths to address concentric artifacts in PCD-CT images. Both phantom and human cadaver experiments were performed at a high gantry rotation speed and clinically relevant radiation dose level to evaluate the spectral and non-spectral imaging performance of the prototype system. Results show that the PCD-CT system has excellent image quality with negligible artifacts after the proposed corrections. Compared with FPD-CBCT images acquired at the same dose level, PCD-CT images demonstrated a 53% reduction in noise variance and additional quantitative imaging capability.
Collapse
|
17
|
Feng M, Ji X, Zhang R, Treb K, Dingle AM, Li K. An experimental method to correct low-frequency concentric artifacts in photon counting CT. Phys Med Biol 2021; 66. [PMID: 34315142 DOI: 10.1088/1361-6560/ac1833] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2021] [Accepted: 07/27/2021] [Indexed: 11/12/2022]
Abstract
Large-area photon counting detectors (PCDs) are usually built by tiling multiple semiconductor panels that often have slightly different spectral responses to input x-rays. As a result of this spectral inconsistency, experimental PCD-CT images of large, human-sized objects may show high-frequency ring artifacts and low-frequency band artifacts. Due to the much larger width of the bands compared with the rings, the concentric artifact problem in PCD-CT images of human-sized objects cannot be adequately addressed by conventional CT ring correction methods. This work presents an experimental method to correct the concentric artifacts in PCD-CT. The method is applicable to not only energy-discriminating PCDs with multiple bins but also PCDs with only a single threshold controller. Its principle is similar to the two-step beam hardening correction method, except that the proposed method uses pixel-specific polynomial functions to address the spectral inconsistency problem across the detector plane. The pixel-specific polynomial coefficients were experimentally calibrated using 15 acrylic sheets and 6 aluminum sheets of known thicknesses. The pixel-specific polynomial functions were used to convert the measured PCD-CT projection data to acrylic- and aluminum-equivalent thicknesses that are energy-independent. The proposed method was experimentally evaluated using a human cadaver head and multiple physical phantoms: two of them contain iodine and one phantom contains dual K-edge contrast materials (gadolinium and iodine). The results show that the proposed method can effectively remove the low-frequency concentric artifacts in PCD-CT images while reducing beam hardening artifacts. In contrast, the conventional CT ring correction algorithm did not adequately address the low-frequency band artifacts. Compared with the direct material decomposition-based correction method, the proposed method not only relaxes the requirement of multi-energy bins but also generates images with lower noise and fewer concentric artifacts.
Collapse
Affiliation(s)
- Mang Feng
- Department of Medical Physics, University of Wisconsin-Madison, 1111 Highland Avenue, Madison, WI 53705, United States of America
| | - Xu Ji
- Department of Medical Physics, University of Wisconsin-Madison, 1111 Highland Avenue, Madison, WI 53705, United States of America
| | - Ran Zhang
- Department of Medical Physics, University of Wisconsin-Madison, 1111 Highland Avenue, Madison, WI 53705, United States of America
| | - Kevin Treb
- Department of Medical Physics, University of Wisconsin-Madison, 1111 Highland Avenue, Madison, WI 53705, United States of America
| | - Aaron M Dingle
- Department of Surgery, University of Wisconsin-Madison, WI 53792, United States of America
| | - Ke Li
- Department of Medical Physics, University of Wisconsin-Madison, 1111 Highland Avenue, Madison, WI 53705, United States of America.,Department of Radiology, University of Wisconsin-Madison, 600 Highland Avenue, Madison, WI 53792, United States of America
| |
Collapse
|
18
|
Ballabriga R, Alozy J, Bandi FN, Campbell M, Egidos N, Fernandez-Tenllado JM, Heijne EHM, Kremastiotis I, Llopart X, Madsen BJ, Pennicard D, Sriskaran V, Tlustos L. Photon Counting Detectors for X-Ray Imaging With Emphasis on CT. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES 2021. [DOI: 10.1109/trpms.2020.3002949] [Citation(s) in RCA: 24] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
19
|
Wang AS, Pelc NJ. Spectral Photon Counting CT: Imaging Algorithms and Performance Assessment. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES 2021; 5:453-464. [PMID: 35419500 PMCID: PMC9000208 DOI: 10.1109/trpms.2020.3007380] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/27/2023]
Abstract
Photon counting x-ray detectors (PCDs) with spectral capabilities have the potential to revolutionize computed tomography (CT) for medical imaging. The ideal PCD provides accurate energy information for each incident x-ray, and at high spatial resolution. This information enables material-specific imaging, enhanced radiation dose efficiency, and improved spatial resolution in CT images. In practice, PCDs are affected by non-idealities, including limited energy resolution, pulse pileup, and cross talk due to charge sharing, K-fluorescence, and Compton scattering. In order to maximize their performance, PCDs must be carefully designed to reduce these effects and then later account for them during correction and post-acquisition steps. This review article examines algorithms for using PCDs in spectral CT applications, including how non-idealities impact image quality. Performance assessment metrics that account for spatial resolution and noise such as the detective quantum efficiency (DQE) can be used to compare different PCD designs, as well as compare PCDs with conventional energy integrating detectors (EIDs). These methods play an important role in enhancing spectral CT images and assessing the overall performance of PCDs.
Collapse
Affiliation(s)
- Adam S Wang
- Departments of Radiology and, by courtesy, Electrical Engineering, Stanford University, Stanford, CA 94305 USA
| | - Norbert J Pelc
- Department of Radiology, Stanford University, Stanford, CA 94305 USA
| |
Collapse
|
20
|
Hsieh SS, Leng S, Rajendran K, Tao S, McCollough CH. Photon Counting CT: Clinical Applications and Future Developments. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES 2021; 5:441-452. [PMID: 34485784 PMCID: PMC8409241 DOI: 10.1109/trpms.2020.3020212] [Citation(s) in RCA: 56] [Impact Index Per Article: 18.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
The use of a photon counting detector in CT (PCD CT) is currently the subject of intense investigation and development. In this review article, we will describe potential clinical applications of this technology with a particular focus on the experience of our own institution with a prototype PCD CT scanner. PCDs have three primary advantages over conventional, energy integrating detectors (EIDs): they provide spectral information without need for a dedicated dual energy protocol; they are immune to electronic noise; and they can be made very high resolution without significant compromises to quantum efficiency. These advantages translate into several clinical applications. Metal artifacts, beam hardening artifacts, and noise streaks from photon starvation can be better mitigated using PCD CT. Certain incidental findings can be better characterized using the spectral information from PCD CT. High-contrast, high-resolution structures such as the temporal bone can be better visualized using PCD CT and at greatly reduced dose. We also discuss new possibilities on the horizon, including new contrast agents, and how anticipated improvements in PCD CT will translate to performance in these applications.
Collapse
Affiliation(s)
- Scott S Hsieh
- Department of Radiology at the Mayo Clinic, Rochester MN 55905 USA
| | - Shuai Leng
- Department of Radiology at the Mayo Clinic, Rochester MN 55905 USA
| | | | - Shengzhen Tao
- Department of Radiology at the Mayo Clinic, Rochester MN 55905 USA
| | | |
Collapse
|
21
|
Wang Q, Salehjahromi M, Yu H. Refined Locally Linear Transform-Based Spectral-Domain Gradient Sparsity and Its Applications in Spectral CT Reconstruction. IEEE ACCESS : PRACTICAL INNOVATIONS, OPEN SOLUTIONS 2021; 9:58537-58548. [PMID: 33996345 PMCID: PMC8118116 DOI: 10.1109/access.2021.3071492] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Spectral computed tomography (CT) is extension of the conventional single spectral CT (SSCT) along the energy dimension, which achieves superior energy resolution and material distinguishability. However, for the state-of-the-art photon counting detector (PCD) based spectral CT, because the emitted photons with a fixed total number for each X-ray beam are divided into several energy bins, the noise level is increased in each reconstructed channel image, and it further leads to an inaccurate material decomposition. To improve the reconstructed image quality and decomposition accuracy, in this work, we first employ a refined locally linear transform to convert the structural similarity among two-dimensional (2D) spectral CT images to a spectral-dimension gradient sparsity. By combining the gradient sparsity in the spatial domain, a global three-dimensional (3D) gradient sparsity is constructed, then measured with L 1-, L 0- and trace-norm, respectively. For each sparsity measurement, we propose the corresponding optimization model, develop the iterative algorithm, and verify the effectiveness and superiority with real datasets.
Collapse
Affiliation(s)
- Qian Wang
- Department of Electrical and Computer Engineering, University of Massachusetts at Lowell, Lowell, MA 01854, USA
| | - Morteza Salehjahromi
- Department of Electrical and Computer Engineering, University of Massachusetts at Lowell, Lowell, MA 01854, USA
| | - Hengyong Yu
- Department of Electrical and Computer Engineering, University of Massachusetts at Lowell, Lowell, MA 01854, USA
| |
Collapse
|
22
|
Willemink MJ, Varga-Szemes A, Schoepf UJ, Codari M, Nieman K, Fleischmann D, Mastrodicasa D. Emerging methods for the characterization of ischemic heart disease: ultrafast Doppler angiography, micro-CT, photon-counting CT, novel MRI and PET techniques, and artificial intelligence. Eur Radiol Exp 2021; 5:12. [PMID: 33763754 PMCID: PMC7991013 DOI: 10.1186/s41747-021-00207-3] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2019] [Accepted: 01/22/2021] [Indexed: 12/24/2022] Open
Abstract
After an ischemic event, disruptive changes in the healthy myocardium may gradually develop and may ultimately turn into fibrotic scar. While these structural changes have been described by conventional imaging modalities mostly on a macroscopic scale-i.e., late gadolinium enhancement at magnetic resonance imaging (MRI)-in recent years, novel imaging methods have shown the potential to unveil an even more detailed picture of the postischemic myocardial phenomena. These new methods may bring advances in the understanding of ischemic heart disease with potential major changes in the current clinical practice. In this review article, we provide an overview of the emerging methods for the non-invasive characterization of ischemic heart disease, including coronary ultrafast Doppler angiography, photon-counting computed tomography (CT), micro-CT (for preclinical studies), low-field and ultrahigh-field MRI, and 11C-methionine positron emission tomography. In addition, we discuss new opportunities brought by artificial intelligence, while addressing promising future scenarios and the challenges for the application of artificial intelligence in the field of cardiac imaging.
Collapse
Affiliation(s)
- Martin J. Willemink
- grid.168010.e0000000419368956Department of Radiology, Stanford University School of Medicine, 300 Pasteur Drive, Stanford, CA 94035 USA
| | - Akos Varga-Szemes
- grid.259828.c0000 0001 2189 3475Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC USA
| | - U. Joseph Schoepf
- grid.259828.c0000 0001 2189 3475Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC USA
| | - Marina Codari
- grid.168010.e0000000419368956Department of Radiology, Stanford University School of Medicine, 300 Pasteur Drive, Stanford, CA 94035 USA
| | - Koen Nieman
- grid.168010.e0000000419368956Division of Cardiovascular Medicine, Stanford University School of Medicine, Stanford, CA USA ,Stanford Cardiovascular Institute, Stanford, CA 94305 USA
| | - Dominik Fleischmann
- grid.168010.e0000000419368956Department of Radiology, Stanford University School of Medicine, 300 Pasteur Drive, Stanford, CA 94035 USA ,Stanford Cardiovascular Institute, Stanford, CA 94305 USA
| | - Domenico Mastrodicasa
- Department of Radiology, Stanford University School of Medicine, 300 Pasteur Drive, Stanford, CA, 94035, USA. .,Stanford Cardiovascular Institute, Stanford, CA, 94305, USA.
| |
Collapse
|
23
|
Quantitative dual contrast photon-counting computed tomography for assessment of articular cartilage health. Sci Rep 2021; 11:5556. [PMID: 33692379 PMCID: PMC7946949 DOI: 10.1038/s41598-021-84800-x] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2020] [Accepted: 02/09/2021] [Indexed: 01/31/2023] Open
Abstract
Photon-counting detector computed tomography (PCD-CT) is a modern spectral imaging technique utilizing photon-counting detectors (PCDs). PCDs detect individual photons and classify them into fixed energy bins, thus enabling energy selective imaging, contrary to energy integrating detectors that detects and sums the total energy from all photons during acquisition. The structure and composition of the articular cartilage cannot be detected with native CT imaging but can be assessed using contrast-enhancement. Spectral imaging allows simultaneous decomposition of multiple contrast agents, which can be used to target and highlight discrete cartilage properties. Here we report, for the first time, the use of PCD-CT to quantify a cationic iodinated CA4+ (targeting proteoglycans) and a non-ionic gadolinium-based gadoteridol (reflecting water content) contrast agents inside human osteochondral tissue (n = 53). We performed PCD-CT scanning at diffusion equilibrium and compared the results against reference data of biomechanical and optical density measurements, and Mankin scoring. PCD-CT enables simultaneous quantification of the two contrast agent concentrations inside cartilage and the results correlate with the structural and functional reference parameters. With improved soft tissue contrast and assessment of proteoglycan and water contents, PCD-CT with the dual contrast agent method is of potential use for the detection and monitoring of osteoarthritis.
Collapse
|
24
|
Abstract
The introduction of photon-counting detectors is expected to be the next major breakthrough in clinical x-ray computed tomography (CT). During the last decade, there has been considerable research activity in the field of photon-counting CT, in terms of both hardware development and theoretical understanding of the factors affecting image quality. In this article, we review the recent progress in this field with the intent of highlighting the relationship between detector design considerations and the resulting image quality. We discuss detector design choices such as converter material, pixel size, and readout electronics design, and then elucidate their impact on detector performance in terms of dose efficiency, spatial resolution, and energy resolution. Furthermore, we give an overview of data processing, reconstruction methods and metrics of imaging performance; outline clinical applications; and discuss potential future developments.
Collapse
Affiliation(s)
- Mats Danielsson
- Department of Physics, KTH Royal Institute of Technology, AlbaNova University Center, SE-106 91 Stockholm, Sweden. Prismatic Sensors AB, AlbaNova University Center, SE-106 91 Stockholm, Sweden
| | | | | |
Collapse
|
25
|
Review of Technical Advancements and Clinical Applications of Photon-counting Computed Tomography in Imaging of the Thorax. J Thorac Imaging 2021; 36:84-94. [PMID: 33399350 DOI: 10.1097/rti.0000000000000569] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
Photon-counting computed tomography (CT) is a developing technology that has the potential to address some limitations of CT imaging and bring about improvements and potentially new applications to this field. Photon-counting detectors have a fundamentally different detection mechanism from conventional CT energy-integrating detectors that can improve dose efficiency, spatial resolution, and energy-discrimination capabilities. In the past decade, promising human studies have been reported in the literature that have demonstrated benefits of this relatively new technology for various clinical applications. In this review, we provide a succinct description of the photon-counting detector technology and its detection mechanism in comparison with energy-integrating detectors in a manner understandable for clinicians and radiologists, introduce benefits and some of the existing challenges present in this technology, and provide an overview of the current status and potential clinical applications of this technology in imaging of the thorax by providing example images acquired with an investigational whole-body photon-counting CT scanner.
Collapse
|
26
|
Hsieh SS, Iniewski K. Improving Paralysis Compensation in Photon Counting Detectors. IEEE TRANSACTIONS ON MEDICAL IMAGING 2021; 40:3-11. [PMID: 32877334 DOI: 10.1109/tmi.2020.3019461] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Photon counting detectors (PCDs) are classically described as being either paralyzable or nonparalyzable. When the PCD is paralyzed, it is no longer sensitive to the detection of additional flux. A recent strategy in PCD design has been to compensate for detector paralysis by embedding specialized paralysis compensation electronics into the application-specific integrated circuit (ASIC). One such compensation mechanism is the pileup trigger, which places an additional energy bin at very high energy that is triggered only during pileup. Another compensation mechanism is the retrigger architecture, which converts a paralyzable PCD into a nonparalyzable PCD. We propose a third mechanism that modifies the retrigger architecture using dedicated secondary counters. We studied the incremental benefit of these three paralysis compensation mechanisms in simulation. We modeled the spectral response using Monte Carlo simulations and then estimated the variance in basis material decomposition of a single pixel using the Cramér-Rao lower bound (CRLB). In the absence of paralysis compensation, noise in basis material images shows sharp increases at moderate flux (near the characteristic count rate) due to contrast inversion and again at high flux. The pileup trigger reduces noise at high flux but does not eliminate contrast inversion. The retrigger architecture eliminates contrast inversion but does not reduce noise at high flux. Our proposed retrigger architecture with dedicated secondary counters reduce noise at both moderate and high flux.
Collapse
|
27
|
Flohr T, Petersilka M, Henning A, Ulzheimer S, Ferda J, Schmidt B. Photon-counting CT review. Phys Med 2020; 79:126-136. [DOI: 10.1016/j.ejmp.2020.10.030] [Citation(s) in RCA: 46] [Impact Index Per Article: 11.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/02/2020] [Revised: 10/26/2020] [Accepted: 10/29/2020] [Indexed: 01/30/2023] Open
|
28
|
Dose Reduction for Sinus and Temporal Bone Imaging Using Photon-Counting Detector CT With an Additional Tin Filter. Invest Radiol 2020; 55:91-100. [PMID: 31770297 DOI: 10.1097/rli.0000000000000614] [Citation(s) in RCA: 82] [Impact Index Per Article: 20.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVE The aim of this study was to quantitatively demonstrate radiation dose reduction for sinus and temporal bone examinations using high-resolution photon-counting detector (PCD) computed tomography (CT) with an additional tin (Sn) filter. MATERIALS AND METHODS A multienergy CT phantom, an anthropomorphic head phantom, and a cadaver head were scanned on a research PCD-CT scanner using ultra-high-resolution mode at 100-kV tube potential with an additional tin filter (Sn-100 kV) and volume CT dose index of 10 mGy. They were also scanned on a commercial CT scanner with an energy-integrating detector (EID) following standard clinical protocols. Thirty patients referred to clinically indicated sinus examinations, and two patients referred to temporal bone examinations were scanned on the PCD-CT system after their clinical scans on an EID-CT. For the sinus cohort, PCD-CT scans were performed using Sn-100 kV at 4 dose levels at 10 mGy (n = 9), 8 mGy (n = 7), 7 mGy (n = 7), and 6 mGy (n = 7), and the clinical EID-CT was performed at 120 kV and 13.7 mGy (mean CT volume dose index). For the temporal bone scans, PCD-CT was performed using Sn-100 kV (10.1 mGy), and EID-CT was performed at 120 kV and routine clinical dose (52.6 and 66 mGy). For both PCD-CT and EID-CT, sinus images were reconstructed using H70 kernel at 0.75-mm slice thickness, and temporal bone images were reconstructed using a U70 kernel at 0.6-mm slice thickness. In addition, iterative reconstruction with a dedicated sharp kernel (V80) was used to obtain high-resolution PCD-CT images from a sinus patient scan to demonstrate improved anatomic delineation. Improvements in spatial resolution from the dedicated sharp kernel was quantified using modulation transfer function measured with a wire phantom. A neuroradiologist assessed the H70 sinus images for visualization of critical anatomical structures in low-dose PCD-CT images and routine-dose EID-CT images using a 5-point Likert scale (structural detection obscured and poor diagnostic confidence, score = 1; improved anatomic delineation and diagnostic confidence, score = 5). Image contrast and noise were measured in representative regions of interest and compared between PCD-CT and EID-CT, and the noise difference between the 2 acquisitions was used to estimate the dose reduction in the sinus and temporal bone patient cohorts. RESULTS The multienergy phantom experiment showed a noise reduction of 26% in the Sn-100 kV PCD-CT image, corresponding to a total dose reduction of 56% compared with EID-CT (clinical dose) without compromising image contrast. The PCD-CT images from the head phantom and the cadaver scans demonstrated a dose reduction of 67% and 83%, for sinus and temporal bone examinations, respectively, compared with EID-CT. In the sinus cohort, PCD-CT demonstrated a mean dose reduction of 67%. The 10- and 8-mGy sinus patient images from PCD-CT were significantly superior to clinical EID-CT for visualization of critical sinus structures (median score = 5 ± 0.82 and P = 0.01 for lesser palatine foramina, median score = 4 ± 0.68 and P = 0.039 for nasomaxillary sutures, and median score = 4 ± 0.96 and P = 0.01 for anterior ethmoid artery canal). The 6- and 7-mGy sinus patient images did not show any significant difference between PCD-CT and EID-CT. In addition, V80 (sharp kernel, 10% modulation transfer function = 18.6 cm) PCD-CT images from a sinus patient scan increased the conspicuity of nasomaxillary sutures compared with the clinical EID-CT images. The temporal bone patient images demonstrated a dose reduction of up to 85% compared with clinical EID-CT images, whereas visualization of inner ear structures such as the incudomalleolar joint were similar between EID-CT and PCD-CT. CONCLUSIONS Phantom and cadaver studies demonstrated dose reduction using Sn-100 kV PCD-CT compared with current clinical EID-CT while maintaining the desired image contrast. Dose reduction was further validated in sinus and temporal bone patient studies. The ultra-high resolution capability from PCD-CT allowed improved anatomical delineation for sinus imaging compared with current clinical standard.
Collapse
|
29
|
So A, Nicolaou S. Spectral Computed Tomography: Fundamental Principles and Recent Developments. Korean J Radiol 2020; 22:86-96. [PMID: 32932564 PMCID: PMC7772378 DOI: 10.3348/kjr.2020.0144] [Citation(s) in RCA: 24] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2020] [Revised: 04/10/2020] [Accepted: 04/13/2020] [Indexed: 12/12/2022] Open
Abstract
CT is a diagnostic tool with many clinical applications. The CT voxel intensity is related to the magnitude of X-ray attenuation, which is not unique to a given material. Substances with different chemical compositions can be represented by similar voxel intensities, making the classification of different tissue types challenging. Compared to the conventional single-energy CT, spectral CT is an emerging technology offering superior material differentiation, which is achieved using the energy dependence of X-ray attenuation in any material. A specific form of spectral CT is dual-energy imaging, in which an additional X-ray attenuation measurement is obtained at a second X-ray energy. Dual-energy CT has been implemented in clinical settings with great success. This paper reviews the theoretical basis and practical implementation of spectral/dual-energy CT.
Collapse
Affiliation(s)
- Aaron So
- Imaging Program, Lawson Health Research Institute, London, Canada.,Department of Medical Biophysics, University of Western Ontario, London, Canada.
| | - Savvas Nicolaou
- Department of Emergency and Trauma Imaging, Vancouver General Hospital, Vancouver, Canada.,Department of Radiology, University of British Columbia, Vancouver, Canada
| |
Collapse
|
30
|
Wang Q, Wu W, Deng S, Zhu Y, Yu H. Locally linear transform based three-dimensional gradient L 0 -norm minimization for spectral CT reconstruction. Med Phys 2020; 47:4810-4826. [PMID: 32740956 DOI: 10.1002/mp.14420] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2019] [Revised: 06/14/2020] [Accepted: 07/21/2020] [Indexed: 11/07/2022] Open
Abstract
PURPOSE Spectral computed tomography (CT) is proposed by extending the conventional CT along the energy dimension. One newly implementation is to employ an energy-discriminating photon counting detector (PCD), which can distinguish photon energy and divide a whole x-ray spectrum into several energy bins with appropriate post-processing steps. The state-of-the-art PCD-based spectral CT has superior energy resolution and material distinguishability, and it further has a great potential in both medical and industrial applications. To improve the reconstruction quality and decomposition accuracy, in this work, we propose an optimization-based spectral CT reconstruction method with an innovational sparsity constraint. METHODS We first employ a locally linear transform to the reconstructed channel images, and the structural similarity along the spectral dimension is effectively converted to a one-dimensional (1D) gradient sparsity. Then, combining the prior knowledge of piecewise constant in the spatial domain (e.g., a two-dimensional (2D) gradient sparsity feature), we unify both spectral and spatial dimensions and establish a joint three-dimensional (3D) gradient sparsity. In addition, we use the L 0 -norm to measure the proposed sparsity and incorporate it as a smoothness constraint to concretize a general optimization framework. Furthermore, we develop the corresponding iterative algorithm to solve the optimization problem. RESULTS Both visual results and quantitative indexes of numerical simulations and phantom experiments demonstrate the proposed method outperform the conventional filtered backprojection (FBP), total variation (TV), 2D L0 -norm (L0 ), and TV with low rank (TVLR)-based methods. From the image and ROI comparisons, we find the proposed method performs well in noise suppression, detail maintenance, and decomposition accuracy. However, the FBP suffers severe noise, the TV and L0 are difficult to work consistently among different energy bins, and the TVLR fails to avoid gray value shift. The image quality assessments, such as peak signal-to-noise ratio (PSNR), normal mean absolute deviation (NMAD). and structural similarity (SSIM), also consistently indicate the proposed method can effectively removing noise and keeping fine structures in both channel-wise reconstructions and material decompositions. CONCLUSIONS By employing a locally linear transform, the structural similarity among spectral channel images is converted to a 1D gradient sparsity and the gray value shift is effectively avoided when the difference measurement is minimized. The 3D L0 -norm jointly and uniformly measures the gradient sparsity in both spectral and spatial dimensions. The cooperation of locally linear transform and 3D L0 -norm well reinforces the global sparse features and keeps the correlation along spectral dimension without bringing gray-value distortions. The corresponding constraint optimization model is fast and stably solved by using an alternative direction technique. Both numerical simulations and phantom experiments confirm the superior performance of the proposed method in noise suppression, structure maintenance, and accurate decomposition.
Collapse
Affiliation(s)
- Qian Wang
- Department of Electrical and Computer Engineering, University of Massachusetts Lowell, Lowell, MA, 01854, USA
| | - Weiwen Wu
- Department of Electrical and Computer Engineering, University of Massachusetts Lowell, Lowell, MA, 01854, USA.,Key Lab of Optoelectronic Technology and Systems, Ministry of Education, Chongqing University, Chongqing, 400044, China
| | - Shiwo Deng
- School of Mathematical Sciences, Capital Normal University, Beijing, 100048, China
| | - Yining Zhu
- School of Mathematical Sciences, Capital Normal University, Beijing, 100048, China
| | - Hengyong Yu
- Department of Electrical and Computer Engineering, University of Massachusetts Lowell, Lowell, MA, 01854, USA
| |
Collapse
|
31
|
Jacobsen MC, Thrower SL. Multi-energy computed tomography and material quantification: Current barriers and opportunities for advancement. Med Phys 2020; 47:3752-3771. [PMID: 32453879 PMCID: PMC8495770 DOI: 10.1002/mp.14241] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2019] [Revised: 04/20/2020] [Accepted: 05/07/2020] [Indexed: 12/21/2022] Open
Abstract
Computed tomography (CT) technology has rapidly evolved since its introduction in the 1970s. It is a highly important diagnostic tool for clinicians as demonstrated by the significant increase in utilization over several decades. However, much of the effort to develop and advance CT applications has been focused on improving visual sensitivity and reducing radiation dose. In comparison to these areas, improvements in quantitative CT have lagged behind. While this could be a consequence of the technological limitations of conventional CT, advanced dual-energy CT (DECT) and photon-counting detector CT (PCD-CT) offer new opportunities for quantitation. Routine use of DECT is becoming more widely available and PCD-CT is rapidly developing. This review covers efforts to address an unmet need for improved quantitative imaging to better characterize disease, identify biomarkers, and evaluate therapeutic response, with an emphasis on multi-energy CT applications. The review will primarily discuss applications that have utilized quantitative metrics using both conventional and DECT, such as bone mineral density measurement, evaluation of renal lesions, and diagnosis of fatty liver disease. Other topics that will be discussed include efforts to improve quantitative CT volumetry and radiomics. Finally, we will address the use of quantitative CT to enhance image-guided techniques for surgery, radiotherapy and interventions and provide unique opportunities for development of new contrast agents.
Collapse
Affiliation(s)
- Megan C. Jacobsen
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA
| | - Sara L. Thrower
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA
| |
Collapse
|
32
|
Persson M, Wang A, Pelc NJ. Detective quantum efficiency of photon-counting CdTe and Si detectors for computed tomography: a simulation study. J Med Imaging (Bellingham) 2020; 7:043501. [PMID: 32715022 DOI: 10.1117/1.jmi.7.4.043501] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2020] [Accepted: 06/30/2020] [Indexed: 11/14/2022] Open
Abstract
Purpose: Developing photon-counting CT detectors requires understanding the impact of parameters, such as converter material, thickness, and pixel size. We apply a linear-systems framework, incorporating spatial and energy resolution, to study realistic silicon (Si) and cadmium telluride (CdTe) detectors at a low count rate. Approach: We compared CdTe detector designs with 0.5 × 0.5 mm 2 and 0.225 × 0.225 mm 2 pixels and Si detector designs with 0.5 × 0.5 mm 2 pixels of 30 and 60 mm active thickness, with and without tungsten scatter blockers. Monte-Carlo simulations of photon transport were used together with Gaussian charge sharing models fitted to published data. Results: For detection in a 300-mm-thick object at 120 kVp, the 0.5- and 0.225-mm pixel CdTe systems have 28% to 41% and 5% to 29% higher detective quantum efficiency (DQE), respectively, than the 60-mm Si system with tungsten, whereas the corresponding numbers for two-material decomposition are 2% lower to 11% higher DQE and 31% to 54% lower DQE compared to Si. We also show that combining these detectors with dual-spectrum acquisition is beneficial. Conclusions: In the low-count-rate regime, CdTe detector systems outperform the Si systems for detection tasks, whereas silicon outperforms one or both of the CdTe systems for material decomposition.
Collapse
Affiliation(s)
- Mats Persson
- Stanford University, Department of Bioengineering, Stanford, California, United States.,Stanford University, Department of Radiology, Stanford, California, United States
| | - Adam Wang
- Stanford University, Department of Radiology, Stanford, California, United States
| | - Norbert J Pelc
- Stanford University, Department of Bioengineering, Stanford, California, United States.,Stanford University, Department of Radiology, Stanford, California, United States.,Stanford University, Department of Electrical Engineering, Stanford, California, United States
| |
Collapse
|
33
|
Grönberg F, Lundberg J, Sjölin M, Persson M, Bujila R, Bornefalk H, Almqvist H, Holmin S, Danielsson M. Feasibility of unconstrained three-material decomposition: imaging an excised human heart using a prototype silicon photon-counting CT detector. Eur Radiol 2020; 30:5904-5912. [PMID: 32588212 PMCID: PMC7554013 DOI: 10.1007/s00330-020-07017-y] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2020] [Revised: 05/11/2020] [Accepted: 06/05/2020] [Indexed: 11/05/2022]
Abstract
Rationale and objectives The purpose of this study was to evaluate the feasibility of unconstrained three-material decomposition in a human tissue specimen containing iodinated contrast agent, using an experimental multi-bin photon-counting silicon detector. It was further to evaluate potential added clinical value compared to a 1st-generation state-of-the-art dual-energy computed tomography system. Materials and methods A prototype photon-counting silicon detector in a bench-top setup for x-ray tomographic imaging was calibrated using a multi-material calibration phantom. A heart with calcified plaque was obtained from a deceased patient, and the coronary arteries were injected with an iodinated contrast agent mixed with gelatin. The heart was imaged in the experimental setup and on a 1st-generation state-of-the-art dual-energy computed tomography system. Projection-based three-material decomposition without any constraints was performed with the photon-counting detector data, and the resulting images were compared with those obtained from the dual-energy system. Results The photon-counting detector images show better separation of iodine and calcium compared to the dual-energy images. Additional experiments confirmed that unbiased estimates of soft tissue, calcium, and iodine could be achieved without any constraints. Conclusion The proposed experimental system could provide added clinical value compared to current dual-energy systems for imaging tasks where mix-up of iodine and calcium is an issue, and the anatomy is sufficiently small to allow iodine to be differentiated from calcium. Considering its previously shown count rate capability, these results show promise for future integration of this detector in a clinical CT scanner. Key Points • Spectral photon-counting detectors can solve some of the fundamental problems with conventional single-energy CT. • Dual-energy methods can be used to differentiate iodine and calcium, but to do so must rely on constraints, since solving for three unknowns with only two measurements is not possible. Photon-counting detectors can improve upon these methods by allowing unconstrained three-material decomposition. • A prototype photon-counting silicon detector with high count rate capability allows performing unconstrained three-material decomposition and qualitatively shows better differentiation of iodine and calcium than dual-energy CT.
Collapse
Affiliation(s)
- Fredrik Grönberg
- Department of Physics, AlbaNova University Center, KTH Royal Institute of Technology, SE-106 91, Stockholm, Sweden.
| | - Johan Lundberg
- Department of Clinical Neuroscience, Karolinska Institutet and the Department of Neuroradiology, Karolinska University Hospital, Stockholm, Sweden
| | - Martin Sjölin
- Department of Physics, AlbaNova University Center, KTH Royal Institute of Technology, SE-106 91, Stockholm, Sweden
| | - Mats Persson
- Department of Physics, AlbaNova University Center, KTH Royal Institute of Technology, SE-106 91, Stockholm, Sweden.,Department of Bioengineering, Stanford University, Stanford, CA, 94305, USA
| | - Robert Bujila
- Medical Radiation Physics and Nuclear Medicine, Karolinska University Hospital, Stockholm, Sweden
| | - Hans Bornefalk
- Department of Physics, AlbaNova University Center, KTH Royal Institute of Technology, SE-106 91, Stockholm, Sweden
| | - Håkan Almqvist
- Department of Clinical Neuroscience, Karolinska Institutet and the Department of Neuroradiology, Karolinska University Hospital, Stockholm, Sweden
| | - Staffan Holmin
- Department of Clinical Neuroscience, Karolinska Institutet and the Department of Neuroradiology, Karolinska University Hospital, Stockholm, Sweden
| | - Mats Danielsson
- Department of Physics, AlbaNova University Center, KTH Royal Institute of Technology, SE-106 91, Stockholm, Sweden
| |
Collapse
|
34
|
Dunning CAS, O'Connell J, Robinson SM, Murphy KJ, Frencken AL, van Veggel FCJM, Iniewski K, Bazalova-Carter M. Photon-counting computed tomography of lanthanide contrast agents with a high-flux 330- μm-pitch cadmium zinc telluride detector in a table-top system. J Med Imaging (Bellingham) 2020; 7:033502. [PMID: 32566695 DOI: 10.1117/1.jmi.7.3.033502] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2019] [Accepted: 05/20/2020] [Indexed: 12/12/2022] Open
Abstract
Purpose: We present photon-counting computed tomography (PCCT) imaging of contrast agent triplets similar in atomic number ( Z ) achieved with a high-flux cadmium zinc telluride (CZT) detector. Approach: The table-top PCCT imaging system included a 330 - μ m -pitch CZT detector of size 8 mm × 24 mm 2 capable of using six energy bins. Four 3D-printed 3-cm-diameter phantoms each contained seven 6-mm-diameter vials with water and low and high concentration solutions of various contrast agents. Lanthanum ( Z = 57 ), gadolinium (Gd) ( Z = 64 ), and lutetium ( Z = 71 ) were imaged together and so were iodine ( Z = 53 ), Gd, and holmium ( Z = 67 ). Each phantom was imaged with 1-mm aluminum-filtered 120-kVp cone beam x rays to produce six energy-binned computed tomography (CT) images. Results: K -edge images were reconstructed using a weighted sum of six CT images, which distinguished each contrast agent with a root-mean-square error (RMSE) of < 0.29 % and 0.51% for the 0.5% and 5% concentrations, respectively. Minimal cross-contamination in each K -edge image was seen, with RMSE values < 0.27 % in vials with no contrast. Conclusion: This is the first preliminary demonstration of simultaneously imaging three similar Z contrast agents with a difference in Z as low as 3.
Collapse
Affiliation(s)
- Chelsea A S Dunning
- University of Victoria, Department of Physics and Astronomy, Victoria, British Columbia, Canada
| | - Jericho O'Connell
- University of Victoria, Department of Physics and Astronomy, Victoria, British Columbia, Canada
| | - Spencer M Robinson
- University of Victoria, Department of Physics and Astronomy, Victoria, British Columbia, Canada
| | - Kevin J Murphy
- University of Victoria, Department of Physics and Astronomy, Victoria, British Columbia, Canada
| | - Adriaan L Frencken
- University of Victoria, Department of Chemistry, Victoria, British Columbia, Canada.,University of Victoria, CAMTEC, Centre for Advanced Materials and Related Technologies, Victoria, British Columbia, Canada
| | - Frank C J M van Veggel
- University of Victoria, Department of Chemistry, Victoria, British Columbia, Canada.,University of Victoria, CAMTEC, Centre for Advanced Materials and Related Technologies, Victoria, British Columbia, Canada
| | - Kris Iniewski
- Redlen Technologies, Saanichton, British Columbia, Canada
| | | |
Collapse
|
35
|
Juntunen MAK, Inkinen SI, Ketola JH, Kotiaho A, Kauppinen M, Winkler A, Nieminen MT. Framework for Photon Counting Quantitative Material Decomposition. IEEE TRANSACTIONS ON MEDICAL IMAGING 2020; 39:35-47. [PMID: 31144630 DOI: 10.1109/tmi.2019.2914370] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
In this paper, the accuracy of material decomposition (MD) using an energy discriminating photon counting detector was studied. An MD framework was established and validated using calcium hydroxyapatite (CaHA) inserts of known densities (50 mg/cm3, 100 mg/cm3, 250 mg/cm3, 400 mg/cm3), and diameters (1.2, 3.0, and 5.0 mm). These inserts were placed in a cardiac rod phantom that mimics a tissue equivalent heart and measured using an experimental photon counting detector cone beam computed tomography (PCD-CBCT) setup. The quantitative coronary calcium scores (density, mass, and volume) obtained from the MD framework were compared with the nominal values. In addition, three different calibration techniques, signal-to-equivalent thickness calibration (STC), polynomial correction (PC), and projected equivalent thickness calibration (PETC) were compared to investigate the effect of the calibration method on the quantitative values. The obtained MD estimates agreed well with the nominal values for density (mass) with mean absolute percent errors (MAPEs) 8 ± 11% (9 ± 15%) and 4 ± 6% (9 ± 14%) for STC and PETC calibration methods, respectively. PC displayed large MAPEs for density (27 ± 9%), and mass (25 ± 12%). Volume estimation resulted in large deviations between true and measured values with notable MAPEs for STC (40 ± 90%), PC (40 ± 80%), and PETC (40 ± 90%). The framework demonstrated the feasibility of quantitative CaHA mass and density scoring using PCD-CBCT.
Collapse
|
36
|
da Silva J, Grönberg F, Cederström B, Persson M, Sjölin M, Alagic Z, Bujila R, Danielsson M. Resolution characterization of a silicon-based, photon-counting computed tomography prototype capable of patient scanning. J Med Imaging (Bellingham) 2019; 6:043502. [PMID: 31620547 DOI: 10.1117/1.jmi.6.4.043502] [Citation(s) in RCA: 25] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2019] [Accepted: 09/18/2019] [Indexed: 11/14/2022] Open
Abstract
Photon-counting detectors are expected to bring a range of improvements to patient imaging with x-ray computed tomography (CT). One is higher spatial resolution. We demonstrate the resolution obtained using a commercial CT scanner where the original energy-integrating detector has been replaced by a single-slice, silicon-based, photon-counting detector. This prototype constitutes the first full-field-of-view silicon-based CT scanner capable of patient scanning. First, the pixel response function and focal spot profile are measured and, combining the two, the system modulation transfer function is calculated. Second, the prototype is used to scan a resolution phantom and a skull phantom. The resolution images are compared to images from a state-of-the-art CT scanner. The comparison shows that for the prototype 19 lp / cm are detectable with the same clarity as 14 lp / cm on the reference scanner at equal dose and reconstruction grid, with more line pairs visible with increasing dose and decreasing image pixel size. The high spatial resolution remains evident in the anatomy of the skull phantom and is comparable to that of other photon-counting CT prototypes present in the literature. We conclude that the deep silicon-based detector used in our study could provide improved spatial resolution in patient imaging without increasing the x-ray dose.
Collapse
Affiliation(s)
- Joakim da Silva
- KTH Royal Institute of Technology, Department of Physics, Stockholm, Sweden
| | - Fredrik Grönberg
- KTH Royal Institute of Technology, Department of Physics, Stockholm, Sweden.,Prismatic Sensors AB, Stockholm, Sweden
| | | | - Mats Persson
- Stanford University, Department of Bioengineering, Stanford, California, United States
| | | | - Zlatan Alagic
- Karolinska University Hospital, Functional Unit for Trauma and Musculoskeletal Radiology, Stockholm, Sweden.,Karolinska Institute, Department of Clinical Science, Intervention and Technology (CLINTEC), Stockholm, Sweden
| | - Robert Bujila
- KTH Royal Institute of Technology, Department of Physics, Stockholm, Sweden.,Karolinska University Hospital, Medical Radiation Physics and Nuclear Medicine, Stockholm, Sweden
| | - Mats Danielsson
- KTH Royal Institute of Technology, Department of Physics, Stockholm, Sweden.,Prismatic Sensors AB, Stockholm, Sweden
| |
Collapse
|
37
|
Fredette NR, Kavuri A, Das M. Multi-step material decomposition for spectral computed tomography. ACTA ACUST UNITED AC 2019; 64:145001. [DOI: 10.1088/1361-6560/ab2b0e] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
38
|
Shi Z, Xie X, Li H, Meng Q, Cong W, Wang G. A Reconfigurable energy-resolving method for a layered edge-on detector. Phys Med Biol 2019; 64:135008. [PMID: 30893656 DOI: 10.1088/1361-6560/ab1149] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Currently, most of the x-ray spectral detectors can extract signals in a set number of energy bins, that inevitably reduces the dynamic range and energy resolution of the imaging system. Inspired by the idea of dynamic thresholding, we previously proposed a pixel architecture and an energy-resolving method for layered edge-on detector. However, the complicated energy exchange mechanism of x-rays in the detector that ultimately affects the practical applications of the layered detectors had not been previously considered. In this study, we modify the energy-depositing model of x-ray photons and propose a reconfigurable energy-resolving method to improve the spectral performance of a layered energy integrating detector. We analyze the errors associated with the energy-resolving process and present our numerical simulation results obtained with energy bins and dynamically changed detection layers to demonstrate the utility and reliability of the proposed method.
Collapse
Affiliation(s)
- Zaifeng Shi
- School of Microelectronics, Tianjin University, Nankai District, Tianjin, People's Republic of China
| | | | | | | | | | | |
Collapse
|
39
|
Simard M, Lapointe A, Lalonde A, Bahig H, Bouchard H. The potential of photon-counting CT for quantitative contrast-enhanced imaging in radiotherapy. ACTA ACUST UNITED AC 2019; 64:115020. [DOI: 10.1088/1361-6560/ab1af1] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
40
|
Leng S, Bruesewitz M, Tao S, Rajendran K, Halaweish AF, Campeau NG, Fletcher JG, McCollough CH. Photon-counting Detector CT: System Design and Clinical Applications of an Emerging Technology. Radiographics 2019; 39:729-743. [PMID: 31059394 PMCID: PMC6542627 DOI: 10.1148/rg.2019180115] [Citation(s) in RCA: 257] [Impact Index Per Article: 51.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2018] [Revised: 06/15/2018] [Accepted: 06/26/2018] [Indexed: 01/01/2023]
Abstract
Photon-counting detector (PCD) CT is an emerging technology that has shown tremendous progress in the last decade. Various types of PCD CT systems have been developed to investigate the benefits of this technology, which include reduced electronic noise, increased contrast-to-noise ratio with iodinated contrast material and radiation dose efficiency, reduced beam-hardening and metal artifacts, extremely high spatial resolution (33 line pairs per centimeter), simultaneous multienergy data acquisition, and the ability to image with and differentiate among multiple CT contrast agents. PCD technology is described and compared with conventional CT detector technology. With the use of a whole-body research PCD CT system as an example, PCD technology and its use for in vivo high-spatial-resolution multienergy CT imaging is discussed. The potential clinical applications, diagnostic benefits, and challenges associated with this technology are then discussed, and examples with phantom, animal, and patient studies are provided. ©RSNA, 2019.
Collapse
Affiliation(s)
- Shuai Leng
- From the Department of Radiology, Mayo Clinic, 200 First St SW, Rochester, MN 55905 (S.L., M.B., S.T., K.R., N.G.C., J.G.F., C.H.M.); and Siemens Healthcare, Malvern, Pa (A.F.H.)
| | - Michael Bruesewitz
- From the Department of Radiology, Mayo Clinic, 200 First St SW, Rochester, MN 55905 (S.L., M.B., S.T., K.R., N.G.C., J.G.F., C.H.M.); and Siemens Healthcare, Malvern, Pa (A.F.H.)
| | - Shengzhen Tao
- From the Department of Radiology, Mayo Clinic, 200 First St SW, Rochester, MN 55905 (S.L., M.B., S.T., K.R., N.G.C., J.G.F., C.H.M.); and Siemens Healthcare, Malvern, Pa (A.F.H.)
| | - Kishore Rajendran
- From the Department of Radiology, Mayo Clinic, 200 First St SW, Rochester, MN 55905 (S.L., M.B., S.T., K.R., N.G.C., J.G.F., C.H.M.); and Siemens Healthcare, Malvern, Pa (A.F.H.)
| | - Ahmed F. Halaweish
- From the Department of Radiology, Mayo Clinic, 200 First St SW, Rochester, MN 55905 (S.L., M.B., S.T., K.R., N.G.C., J.G.F., C.H.M.); and Siemens Healthcare, Malvern, Pa (A.F.H.)
| | - Norbert G. Campeau
- From the Department of Radiology, Mayo Clinic, 200 First St SW, Rochester, MN 55905 (S.L., M.B., S.T., K.R., N.G.C., J.G.F., C.H.M.); and Siemens Healthcare, Malvern, Pa (A.F.H.)
| | - Joel G. Fletcher
- From the Department of Radiology, Mayo Clinic, 200 First St SW, Rochester, MN 55905 (S.L., M.B., S.T., K.R., N.G.C., J.G.F., C.H.M.); and Siemens Healthcare, Malvern, Pa (A.F.H.)
| | - Cynthia H. McCollough
- From the Department of Radiology, Mayo Clinic, 200 First St SW, Rochester, MN 55905 (S.L., M.B., S.T., K.R., N.G.C., J.G.F., C.H.M.); and Siemens Healthcare, Malvern, Pa (A.F.H.)
| |
Collapse
|
41
|
Bläckberg L, Sajedi S, Mandl S, Mohan A, Vittum B, El Fakhri G, Sabet H. Exploring light confinement in laser-processed LYSO:Ce for photon counting CT application. Phys Med Biol 2019; 64:095020. [PMID: 30897557 PMCID: PMC7191943 DOI: 10.1088/1361-6560/ab1213] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
With the goal of developing a low-cost scintillator-based photon counting detector (PCD) with high dose efficiency suitable for CT, the light transport characteristics in LYSO:Ce detectors containing laser induced optical barriers (LIOB) are simulated. Light confinement and light collection efficiencies (LCE) are studied for a variety of optical barrier patterns and properties (refractive index (RI) and barrier/crystal interface roughness). Up to 80% confinement is achievable with a simple pixel pattern with one barrier wall separating each pixel coupled one-to-one to a photodetector (PD) pixel. Confinement is heavily dependent on barrier properties, and rough interfaces and higher RI results in increased cross-talk. Three approaches to enhance performance beyond the basic pattern are explored: (1) Multiple barrier walls separating each crystal pixel. (2) Introduction of long and short range confinement by having multiple crystal pixels per PD pixel. (3) Combination of LIOB and laser ablation (LA). (1) Is effective for rough interfaces where confinement can be increased by up to 24% for double compared to single walls. (2) Results in high confinement in the pixel centered on the PD pixel, but lower confinement closer to the PD edge. This feature may be explored to achieve spatial resolution beyond the PD pixel size using light sharing based positioning algorithms. (3) Can increase confinement for smooth interfaces using a smooth ablation in the bottom part of the crystal. A general trend across all configurations is a trade-off between light confinement and LCE. The LCE attainable is found comparable to that for mechanically pixelated arrays. While the confinement achievable with LIOB is always lower compared to a mechanically pixelated array, the former may offer a high level of flexibility in terms of detector design. This, in combination with the possibility to fabricate sub-mm pixels in a cost-effective manner, makes LIOB a promising technology for scintillator-based PCDs.
Collapse
Affiliation(s)
- L Bläckberg
- Department of Radiology, Gordon Center for Medical Imaging, Massachusetts General Hospital and Harvard Medical School, Boston, MA, United States of America
| | | | | | | | | | | | | |
Collapse
|
42
|
Curtis TE, Roeder RK. Quantification of multiple mixed contrast and tissue compositions using photon-counting spectral computed tomography. J Med Imaging (Bellingham) 2019; 6:013501. [PMID: 30840726 DOI: 10.1117/1.jmi.6.1.013501] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2018] [Accepted: 01/22/2019] [Indexed: 12/19/2022] Open
Abstract
Quantitative material decomposition of multiple mixed, or spatially coincident, contrast agent (gadolinium and iodine) and tissue (calcium and water) compositions is demonstrated using photon-counting spectral computed tomography (CT). Material decomposition is performed using constrained maximum likelihood estimation (MLE) in the image domain. MLE is calibrated by multiple linear regression of all pure material compositions, which exhibits a strong correlation ( R 2 > 0.91 ) between the measured x-ray attenuation in each photon energy bin and known concentrations in the calibration phantom. Material decomposition of mixed compositions in the sample phantom provides color material concentration maps that clearly identify and differentiate each material. The measured area under the receiver operating characteristic curve is > 0.95 , indicating highly accurate material identification. Material decomposition also provides accurate quantitative estimates of material concentrations in mixed compositions with a root-mean-squared error < 12 % of the maximum concentration for each material. Thus, photon-counting spectral CT enables quantitative molecular imaging of multiple spatially coincident contrast agent (gadolinium and iodine) and tissue (calcium and water) compositions, which is not possible with current clinical molecular imaging modalities, such as nuclear imaging and magnetic resonance imaging.
Collapse
Affiliation(s)
- Tyler E Curtis
- University of Notre Dame, Department of Aerospace and Mechanical Engineering, Bioengineering Graduate Program, Notre Dame, Indiana, United States
| | - Ryan K Roeder
- University of Notre Dame, Department of Aerospace and Mechanical Engineering, Bioengineering Graduate Program, Notre Dame, Indiana, United States
| |
Collapse
|
43
|
Boigné E, Muhunthan P, Mohaddes D, Wang Q, Sobhani S, Hinshaw W, Ihme M. X-ray Computed Tomography for Flame-Structure Analysis of Laminar Premixed Flames. COMBUSTION AND FLAME 2019; 200:142-154. [PMID: 30532316 PMCID: PMC6278941 DOI: 10.1016/j.combustflame.2018.11.015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
Quantitative X-ray computed tomography (XCT) diagnostics for reacting flows are developed and demonstrated in application to premixed flames in open and optically inaccessible geometries. A laboratory X-ray scanner is employed to investigate methane/air flames that were diluted with krypton as an inert radiodense tracer gas. Effects of acquisition rate and tracer gas concentration on the signal-to-noise ratio are examined. It is shown that statistically converged three-dimensional attenuation measurements can be obtained with limited impact from the tracer gas and within an acceptable acquisition time. Specific aspects of the tomographic reconstruction and the experimental procedure are examined, with particular emphasis on the quantification of experimental uncertainties. A method is developed to determine density and temperature from the X-ray attenuation measurements. These experiments are complemented by one- and multi-dimensional calculations to quantify the influence of krypton on the flame behavior. To demonstrate the merit of XCT for optically inaccessible flames, measurements of a complex flame geometry in a tubular confinement are performed. The use of a coflow to provide a uniform tracer-gas concentration is shown to improve the quantitative temperature evaluation. These measurements demonstrate the viability of XCT for flame-structure analysis and multi-dimensional temperature measurements using laboratory X-ray systems. Further opportunities for improving this diagnostic are discussed.
Collapse
Affiliation(s)
- Emeric Boigné
- Department of Mechanical Engineering, Stanford University, Stanford, CA 94305, USA
| | - Priyanka Muhunthan
- Department of Mechanical Engineering, Stanford University, Stanford, CA 94305, USA
| | - Danyal Mohaddes
- Department of Mechanical Engineering, Stanford University, Stanford, CA 94305, USA
| | - Qing Wang
- Department of Mechanical Engineering, Stanford University, Stanford, CA 94305, USA
| | - Sadaf Sobhani
- Department of Mechanical Engineering, Stanford University, Stanford, CA 94305, USA
| | - Waldo Hinshaw
- Department of Radiology, Stanford University, Stanford, CA 94305, USA
| | - Matthias Ihme
- Department of Mechanical Engineering, Stanford University, Stanford, CA 94305, USA
| |
Collapse
|
44
|
Leng S, Rajendran K, Gong H, Zhou W, Halaweish AF, Henning A, Kappler S, Baer M, Fletcher JG, McCollough CH. 150-μm Spatial Resolution Using Photon-Counting Detector Computed Tomography Technology: Technical Performance and First Patient Images. Invest Radiol 2018; 53:655-662. [PMID: 29847412 PMCID: PMC6173631 DOI: 10.1097/rli.0000000000000488] [Citation(s) in RCA: 135] [Impact Index Per Article: 22.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVE The aims of this study were to quantitatively assess two new scan modes on a photon-counting detector computed tomography system, each designed to maximize spatial resolution, and to qualitatively demonstrate potential clinical impact using patient data. MATERIALS AND METHODS This Health Insurance Portability Act-compliant study was approved by our institutional review board. Two high-spatial-resolution scan modes (Sharp and UHR) were evaluated using phantoms to quantify spatial resolution and image noise, and results were compared with the standard mode (Macro). Patients were scanned using a conventional energy-integrating detector scanner and the photon-counting detector scanner using the same radiation dose. In first patient images, anatomic details were qualitatively evaluated to demonstrate potential clinical impact. RESULTS Sharp and UHR modes had a 69% and 87% improvement in in-plane spatial resolution, respectively, compared with Macro mode (10% modulation-translation-function values of 16.05, 17.69, and 9.48 lp/cm, respectively). The cutoff spatial frequency of the UHR mode (32.4 lp/cm) corresponded to a limiting spatial resolution of 150 μm. The full-width-at-half-maximum values of the section sensitivity profiles were 0.41, 0.44, and 0.67 mm for the thinnest image thickness for each mode (0.25, 0.25, and 0.5 mm, respectively). At the same in-plane spatial resolution, Sharp and UHR images had up to 15% lower noise than Macro images. Patient images acquired in Sharp mode demonstrated better delineation of fine anatomic structures compared with Macro mode images. CONCLUSIONS Phantom studies demonstrated superior resolution and noise properties for the Sharp and UHR modes relative to the standard Macro mode and patient images demonstrated the potential benefit of these scan modes for clinical practice.
Collapse
Affiliation(s)
- Shuai Leng
- Department of Radiology, Mayo Clinic, Rochester, MN
| | | | - Hao Gong
- Department of Radiology, Mayo Clinic, Rochester, MN
| | - Wei Zhou
- Department of Radiology, Mayo Clinic, Rochester, MN
| | | | | | | | | | | | | |
Collapse
|
45
|
Persson M, Rajbhandary PL, Pelc NJ. A framework for performance characterization of energy-resolving photon-counting detectors. Med Phys 2018; 45:4897-4915. [PMID: 30191571 DOI: 10.1002/mp.13172] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2018] [Revised: 07/19/2018] [Accepted: 08/29/2018] [Indexed: 01/12/2023] Open
Abstract
PURPOSE Photon-counting, energy-resolving detectors are subject to intense research interest, and there is a need for a general framework for performance assessment of these detectors. The commonly used linear-systems theory framework, which measures detector performance in terms of noise-equivalent quanta (NEQ) and detective quantum efficiency (DQE) is widely used for characterizing conventional x-ray detectors but does not take energy-resolving capabilities into account. The purpose of this work is to extend this framework to encompass energy-resolving photon-counting detectors and elucidate how the imperfect energy response and other imperfections in real-world detectors affect imaging performance, both for feature detection and for material quantification tasks. METHOD We generalize NEQ and DQE to matrix-valued quantities as functions of spatial frequency, and show how these matrices can be calculated from simple Monte Carlo simulations. To demonstrate how the new metrics can be interpreted, we compute them for simplified models of fluorescence and Compton scatter in a photon-counting detector and for a Monte Carlo model of a CdTe detector with 0.5 × 0.5 mm 2 pixels. RESULTS Our results show that the ideal-linear-observer performance for any detection or material quantification task can be calculated from the proposed generalized NEQ and DQE metrics. We also demonstrate that the proposed NEQ metric is closely related to a generalized version of the Cramér-Rao lower bound commonly used for assessing material quantification performance. Off-diagonal elements in the NEQ and DQE matrices are shown to be related to loss of energy information due to imperfect energy resolution. The Monte Carlo model of the CdTe detector predicts a zero-frequency dose efficiency relative to an ideal detector of 0.86 and 0.65 for detecting water and bone, respectively. When the task instead is to quantify these materials, the corresponding values are 0.34 for water and 0.26 for bone. CONCLUSIONS We have developed a framework for assessing the performance of photon-counting energy-resolving detectors and shown that the matrix-valued NEQ and DQE metrics contain sufficient information for calculating the dose efficiency for both detection and quantification tasks, the task having any spatial and energy dependence. This framework will be beneficial for the development and optimization of photon-counting x-ray detectors.
Collapse
Affiliation(s)
- Mats Persson
- Departments of Bioengineering and Radiology, Stanford University, Stanford, CA, 94305, USA
| | - Paurakh L Rajbhandary
- Departments of Electrical Engineering and Radiology, Stanford University, Stanford, CA, 94305, USA
| | - Norbert J Pelc
- Departments of Bioengineering, Radiology and Electrical Engineering, Stanford University, Stanford, CA, 94305, USA
| |
Collapse
|
46
|
Taasti VT, Hansen DC, Michalak GJ, Deisher AJ, Kruse JJ, Muren LP, Petersen JBB, McCollough CH. Theoretical and experimental analysis of photon counting detector CT for proton stopping power prediction. Med Phys 2018; 45:5186-5196. [PMID: 30191573 DOI: 10.1002/mp.13173] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2017] [Revised: 07/25/2018] [Accepted: 08/31/2018] [Indexed: 11/08/2022] Open
Abstract
PURPOSE Photon counting detectors (PCDs) are being introduced in advanced x-ray computed tomography (CT) scanners. From a single PCD-CT acquisition, multiple images can be reconstructed, each based on only a part of the original x-ray spectrum. In this study, we investigated whether PCD-CT can be used to estimate stopping power ratios (SPRs) for proton therapy treatment planning, both by comparing to other SPR methods proposed for single energy CT (SECT) and dual energy CT (DECT) as well as to experimental measurements. METHODS A previously developed DECT-based SPR estimation method was adapted to PCD-CT data, by adjusting the estimation equations to allow for more energy spectra. The method was calibrated directly on noisy data to increase the robustness toward image noise. The new PCD SPR estimation method was tested in theoretical calculations as well as in an experimental setup, using both four and two energy bin PCD-CT images, and through comparison to two other SPR methods proposed for SECT and DECT. These two methods were also evaluated on PCD-CT images, full spectrum (one-bin) or two-bin images, respectively. In a theoretical framework, we evaluated the effect of patient-specific tissue variations (density and elemental composition) and image noise on the SPR accuracy; the latter effect was assessed by applying three different noise levels (low, medium, and high noise). SPR estimates derived using real PCD-CT images were compared to experimentally measured SPRs in nine organic tissue samples, including fat, muscle, and bone tissues. RESULTS For the theoretical calculations, the root-mean-square error (RMSE) of the SPR estimation was 0.1% for the new PCD method using both two and four energy bins, compared to 0.2% and 0.7% for the DECT- and SECT-based method, respectively. The PCD method was found to be very robust toward CT image noise, with a RMSE of 2.7% when high noise was added to the CT numbers. Introducing tissue variations, the RMSE only increased to 0.5%; even when adding high image noise to the changed tissues, the RMSE stayed within 3.1%. In the experimental measurements, the RMSE over the nine tissue samples was 0.8% when using two energy bins, and 1.0% for the four-bin images. CONCLUSIONS In all tested cases, the new PCD method produced similar or better results than the SECT- and DECT-based methods, showing an overall improvement of the SPR accuracy. This study thus demonstrated that PCD-CT scans will be a qualified candidate for SPR estimations.
Collapse
Affiliation(s)
- Vicki T Taasti
- Department of Medical Physics, Aarhus University Hospital, Aarhus, Denmark
| | - David C Hansen
- Department of Medical Physics, Aarhus University Hospital, Aarhus, Denmark
| | | | - Amanda J Deisher
- Department of Radiation Oncology, Mayo Clinic, Rochester, MN, USA
| | - Jon J Kruse
- Department of Radiation Oncology, Mayo Clinic, Rochester, MN, USA
| | - Ludvig P Muren
- Department of Medical Physics, Aarhus University Hospital, Aarhus, Denmark
| | | | | |
Collapse
|
47
|
Willemink MJ, Persson M, Pourmorteza A, Pelc NJ, Fleischmann D. Photon-counting CT: Technical Principles and Clinical Prospects. Radiology 2018; 289:293-312. [PMID: 30179101 DOI: 10.1148/radiol.2018172656] [Citation(s) in RCA: 577] [Impact Index Per Article: 96.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
Photon-counting CT is an emerging technology with the potential to dramatically change clinical CT. Photon-counting CT uses new energy-resolving x-ray detectors, with mechanisms that differ substantially from those of conventional energy-integrating detectors. Photon-counting CT detectors count the number of incoming photons and measure photon energy. This technique results in higher contrast-to-noise ratio, improved spatial resolution, and optimized spectral imaging. Photon-counting CT can reduce radiation exposure, reconstruct images at a higher resolution, correct beam-hardening artifacts, optimize the use of contrast agents, and create opportunities for quantitative imaging relative to current CT technology. In this review, the authors will explain the technical principles of photon-counting CT in nonmathematical terms for radiologists and clinicians. Following a general overview of the current status of photon-counting CT, they will explain potential clinical applications of this technology.
Collapse
Affiliation(s)
- Martin J Willemink
- From the Department of Radiology (M.J.W., M.P., N.J.P., D.F.) and Stanford Cardiovascular Institute (D.F.), Stanford University School of Medicine, 300 Pasteur Dr, S-072, Stanford, CA 94305-5105; Department of Radiology, University Medical Center Utrecht, Utrecht, the Netherlands (M.J.W.); Departments of Bioengineering (M.P., N.J.P.) and Electrical Engineering (N.J.P.), Stanford University, Stanford, Calif; Department of Radiology and Department of Imaging Sciences and Biomedical Informatics, Emory University School of Medicine, Atlanta, Ga (A.P.)
| | - Mats Persson
- From the Department of Radiology (M.J.W., M.P., N.J.P., D.F.) and Stanford Cardiovascular Institute (D.F.), Stanford University School of Medicine, 300 Pasteur Dr, S-072, Stanford, CA 94305-5105; Department of Radiology, University Medical Center Utrecht, Utrecht, the Netherlands (M.J.W.); Departments of Bioengineering (M.P., N.J.P.) and Electrical Engineering (N.J.P.), Stanford University, Stanford, Calif; Department of Radiology and Department of Imaging Sciences and Biomedical Informatics, Emory University School of Medicine, Atlanta, Ga (A.P.)
| | - Amir Pourmorteza
- From the Department of Radiology (M.J.W., M.P., N.J.P., D.F.) and Stanford Cardiovascular Institute (D.F.), Stanford University School of Medicine, 300 Pasteur Dr, S-072, Stanford, CA 94305-5105; Department of Radiology, University Medical Center Utrecht, Utrecht, the Netherlands (M.J.W.); Departments of Bioengineering (M.P., N.J.P.) and Electrical Engineering (N.J.P.), Stanford University, Stanford, Calif; Department of Radiology and Department of Imaging Sciences and Biomedical Informatics, Emory University School of Medicine, Atlanta, Ga (A.P.)
| | - Norbert J Pelc
- From the Department of Radiology (M.J.W., M.P., N.J.P., D.F.) and Stanford Cardiovascular Institute (D.F.), Stanford University School of Medicine, 300 Pasteur Dr, S-072, Stanford, CA 94305-5105; Department of Radiology, University Medical Center Utrecht, Utrecht, the Netherlands (M.J.W.); Departments of Bioengineering (M.P., N.J.P.) and Electrical Engineering (N.J.P.), Stanford University, Stanford, Calif; Department of Radiology and Department of Imaging Sciences and Biomedical Informatics, Emory University School of Medicine, Atlanta, Ga (A.P.)
| | - Dominik Fleischmann
- From the Department of Radiology (M.J.W., M.P., N.J.P., D.F.) and Stanford Cardiovascular Institute (D.F.), Stanford University School of Medicine, 300 Pasteur Dr, S-072, Stanford, CA 94305-5105; Department of Radiology, University Medical Center Utrecht, Utrecht, the Netherlands (M.J.W.); Departments of Bioengineering (M.P., N.J.P.) and Electrical Engineering (N.J.P.), Stanford University, Stanford, Calif; Department of Radiology and Department of Imaging Sciences and Biomedical Informatics, Emory University School of Medicine, Atlanta, Ga (A.P.)
| |
Collapse
|
48
|
Baveye PC, Otten W, Kravchenko A, Balseiro-Romero M, Beckers É, Chalhoub M, Darnault C, Eickhorst T, Garnier P, Hapca S, Kiranyaz S, Monga O, Mueller CW, Nunan N, Pot V, Schlüter S, Schmidt H, Vogel HJ. Emergent Properties of Microbial Activity in Heterogeneous Soil Microenvironments: Different Research Approaches Are Slowly Converging, Yet Major Challenges Remain. Front Microbiol 2018; 9:1929. [PMID: 30210462 PMCID: PMC6119716 DOI: 10.3389/fmicb.2018.01929] [Citation(s) in RCA: 61] [Impact Index Per Article: 10.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2018] [Accepted: 07/30/2018] [Indexed: 01/17/2023] Open
Abstract
Over the last 60 years, soil microbiologists have accumulated a wealth of experimental data showing that the bulk, macroscopic parameters (e.g., granulometry, pH, soil organic matter, and biomass contents) commonly used to characterize soils provide insufficient information to describe quantitatively the activity of soil microorganisms and some of its outcomes, like the emission of greenhouse gasses. Clearly, new, more appropriate macroscopic parameters are needed, which reflect better the spatial heterogeneity of soils at the microscale (i.e., the pore scale) that is commensurate with the habitat of many microorganisms. For a long time, spectroscopic and microscopic tools were lacking to quantify processes at that scale, but major technological advances over the last 15 years have made suitable equipment available to researchers. In this context, the objective of the present article is to review progress achieved to date in the significant research program that has ensued. This program can be rationalized as a sequence of steps, namely the quantification and modeling of the physical-, (bio)chemical-, and microbiological properties of soils, the integration of these different perspectives into a unified theory, its upscaling to the macroscopic scale, and, eventually, the development of new approaches to measure macroscopic soil characteristics. At this stage, significant progress has been achieved on the physical front, and to a lesser extent on the (bio)chemical one as well, both in terms of experiments and modeling. With regard to the microbial aspects, although a lot of work has been devoted to the modeling of bacterial and fungal activity in soils at the pore scale, the appropriateness of model assumptions cannot be readily assessed because of the scarcity of relevant experimental data. For significant progress to be made, it is crucial to make sure that research on the microbial components of soil systems does not keep lagging behind the work on the physical and (bio)chemical characteristics. Concerning the subsequent steps in the program, very little integration of the various disciplinary perspectives has occurred so far, and, as a result, researchers have not yet been able to tackle the scaling up to the macroscopic level. Many challenges, some of them daunting, remain on the path ahead. Fortunately, a number of these challenges may be resolved by brand new measuring equipment that will become commercially available in the very near future.
Collapse
Affiliation(s)
- Philippe C. Baveye
- UMR ECOSYS, AgroParisTech, Université Paris-Saclay, Thiverval-Grignon, rance
| | - Wilfred Otten
- School of Water, Energy and Environment, Cranfield University, Cranfield, United Kingdom
| | - Alexandra Kravchenko
- Department of Plant, Soil and Microbial Sciences, Michigan State University, East Lansing, MI, United States
| | - María Balseiro-Romero
- UMR ECOSYS, AgroParisTech, Université Paris-Saclay, Thiverval-Grignon, rance
- Department of Soil Science and Agricultural Chemistry, Centre for Research in Environmental Technologies, Universidade de Santiago de Compostela, Santiago de Compostela, Spain
| | - Éléonore Beckers
- Soil–Water–Plant Exchanges, Terra Research Centre, BIOSE, Gembloux Agro-Bio Tech, University of Liège, Gembloux, Belgium
| | - Maha Chalhoub
- UMR ECOSYS, INRA, Université Paris-Saclay, Thiverval-Grignon, France
| | - Christophe Darnault
- Laboratory of Hydrogeoscience and Biological Engineering, L.G. Rich Environmental Laboratory, Department of Environmental Engineering and Earth Sciences, Clemson University, Clemson, SC, United States
| | - Thilo Eickhorst
- Faculty 2 Biology/Chemistry, University of Bremen, Bremen, Germany
| | - Patricia Garnier
- UMR ECOSYS, INRA, Université Paris-Saclay, Thiverval-Grignon, France
| | - Simona Hapca
- Dundee Epidemiology and Biostatistics Unit, School of Medicine, University of Dundee, Dundee, United Kingdom
| | - Serkan Kiranyaz
- Department of Electrical Engineering, Qatar University, Doha, Qatar
| | - Olivier Monga
- Institut de Recherche pour le Développement, Bondy, France
| | - Carsten W. Mueller
- Lehrstuhl für Bodenkunde, Technical University of Munich, Freising, Germany
| | - Naoise Nunan
- Institute of Ecology and Environmental Sciences – Paris, Sorbonne Universités, CNRS, IRD, INRA, P7, UPEC, Paris, France
| | - Valérie Pot
- UMR ECOSYS, INRA, Université Paris-Saclay, Thiverval-Grignon, France
| | - Steffen Schlüter
- Soil System Science, Helmholtz-Zentrum für Umweltforschung GmbH – UFZ, Leipzig, Germany
| | - Hannes Schmidt
- Terrestrial Ecosystem Research, Department of Microbiology and Ecosystem Science, Research Network ‘Chemistry meets Microbiology’, University of Vienna, Vienna, Austria
| | - Hans-Jörg Vogel
- Soil System Science, Helmholtz-Zentrum für Umweltforschung GmbH – UFZ, Leipzig, Germany
- Institute of Soil Science and Plant Nutrition, Martin Luther University of Halle-Wittenberg, Halle, Germany
| |
Collapse
|
49
|
Rajbhandary PL, Hsieh SS, Pelc NJ. Effect of Spectral Degradation and Spatio-Energy Correlation in X-Ray PCD for Imaging. IEEE TRANSACTIONS ON MEDICAL IMAGING 2018; 37:1910-1919. [PMID: 29993882 DOI: 10.1109/tmi.2018.2834369] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
Charge sharing, scatter, and fluorescence events in a photon counting detector can result in counting of a single incident photon in multiple neighboring pixels, each at a fraction of the true energy. This causes energy distortion and correlation of data across energy bins in neighboring pixels (spatio-energy correlation), with the severity depending on the detector pixel size and detector material. If a "macro-pixel" is formed by combining the counts from multiple adjacent small pixels, it will exhibit correlations across its energy bins. Understanding these effects can be crucial for detector design and for model-based imaging applications. This paper investigates the impact of these effects in basis material and effective monoenergetic estimates using the Cramér-Rao Lower Bound. To do so, we derive a correlation model for the multi-counting events. CdTe detectors with grids of pixels with side length of $250~\mu \text{m}$ , $500~\mu \text{m}$ , and 1 mm were compared, with binning of $4\times4$ , $2\times2$ , and $1\times1$ pixels, respectively, to keep the same net 1 mm2 aperture constant. The same flux was applied to each. The mean and covariance matrix of measured photon counts were derived analytically using spatio-energy response functions precomputed from Monte Carlo simulations. Our results show that a 1 mm2 macro-pixel with $250\times 250\,\,\mu \text{m}^{\textsf {2}}$ sub-pixels shows 35% higher standard deviation than a single 1 mm2 pixel for material-specific imaging, while the penalty for effective monoenergetic imaging is <10% compared with a single 1 mm $^{\textsf {2}}$ pixel. Potential benefits of sub-pixels (higher spatial resolution and lower pulse pile-up effects) are important but were not investigated here.
Collapse
|
50
|
Zhou W, Montoya J, Gutjahr R, Ferrero A, Halaweish A, Kappler S, McCollough C, Leng S. Lung nodule volume quantification and shape differentiation with an ultra-high resolution technique on a photon-counting detector computed tomography system. J Med Imaging (Bellingham) 2017; 4:043502. [PMID: 29181429 DOI: 10.1117/1.jmi.4.4.043502] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2017] [Accepted: 11/01/2017] [Indexed: 01/07/2023] Open
Abstract
An ultra-high resolution (UHR) mode, with a detector pixel size of [Formula: see text] relative to isocenter, has been implemented on a whole body research photon-counting detector (PCD) computed tomography (CT) system. Twenty synthetic lung nodules were scanned using UHR and conventional resolution (macro) modes and reconstructed with medium and very sharp kernels. Linear regression was used to compare measured nodule volumes from CT images to reference volumes. The full-width-at-half-maximum of the calculated curvature histogram for each nodule was used as a shape index, and receiver operating characteristic analysis was performed to differentiate sphere- and star-shaped nodules. Results showed a strong linear relationship between measured nodule volumes and reference volumes for both modes. The overall volume estimation was more accurate using UHR mode and the very sharp kernel, having 4.8% error compared with 10.5% to 12.6% error in the macro mode. The improvement in volume measurements using the UHR mode was more evident for small nodule sizes or star-shaped nodules. Images from the UHR mode with the very sharp kernel consistently demonstrated the best performance [[Formula: see text]] for separating star- from sphere-shaped nodules, showing advantages of UHR mode on a PCD CT scanner for lung nodule characterization.
Collapse
Affiliation(s)
- Wei Zhou
- Mayo Clinic, Department of Radiology, Rochester, Minnesota, United States
| | - Juan Montoya
- Mayo Clinic, Department of Radiology, Rochester, Minnesota, United States
| | - Ralf Gutjahr
- Technical University of Munich, CAMP, Garching (Munich), Germany.,Siemens Healthcare, Forchheim, Germany
| | - Andrea Ferrero
- Mayo Clinic, Department of Radiology, Rochester, Minnesota, United States
| | | | | | - Cynthia McCollough
- Mayo Clinic, Department of Radiology, Rochester, Minnesota, United States
| | - Shuai Leng
- Mayo Clinic, Department of Radiology, Rochester, Minnesota, United States
| |
Collapse
|