1
|
Haggmark I, Shaker K, Hertz HM. In Silico Phase-Contrast X-Ray Imaging of Anthropomorphic Voxel-Based Phantoms. IEEE TRANSACTIONS ON MEDICAL IMAGING 2021; 40:539-548. [PMID: 33055024 DOI: 10.1109/tmi.2020.3031318] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Propagation-based phase-contrast X-ray imaging is an emerging technique that can improve dose efficiency in clinical imaging. In silico tools are key to understanding the fundamental imaging mechanisms and develop new applications. Here, due to the coherent nature of the phase-contrast effects, tools based on wave propagation (WP) are preferred over Monte Carlo (MC) based methods. WP simulations require very high wave-front sampling which typically limits simulations to small idealized objects. Virtual anthropomorphic voxel-based phantoms are typically provided with a resolution lower than imposed sampling requirements and, thus, cannot be directly translated for use in WP simulations. In the present paper we propose a general strategy to enable the use of these phantoms for WP simulations. The strategy is based on upsampling in the 3D domain followed by projection resulting in high-resolution maps of the projected thickness for each phantom material. These maps can then be efficiently used for simulations of Fresnel diffraction to generate in silico phase-contrast X-ray images. We demonstrate the strategy on an anthropomorphic breast phantom to simulate propagation-based phase-contrast mammography using a laboratory micro-focus X-ray source.
Collapse
|
2
|
Soliman MA, Guccione J, Reiter AM, Moawad AW, Etchison A, Kamel S, Khatchikian AD, Elsayes KM. Current Concepts in Multi-Modality Imaging of Solid Tumor Angiogenesis. Cancers (Basel) 2020; 12:cancers12113239. [PMID: 33153067 PMCID: PMC7692820 DOI: 10.3390/cancers12113239] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2020] [Revised: 10/15/2020] [Accepted: 10/19/2020] [Indexed: 12/11/2022] Open
Abstract
Simple Summary The recent increase in the use of targeted molecular therapy including anti-angiogenetic agents in cancer treatment necessitate the use of robust tools to assess and guide treatment. Angiogenesis, the formation of new disorganized blood vessels, is used by tumor cells to grow and spread using different mechanisms that could be targeted by anti-angiogenetic agents. In this review, we discuss the biological principles of tumor angiogenesis and the imaging modalities that could provide information beyond gross tumor size and morphology to capture the efficacy of anti-angiogenetic therapeutic response. Abstract There have been rapid advancements in cancer treatment in recent years, including targeted molecular therapy and the emergence of anti-angiogenic agents, which necessitate the need to quickly and accurately assess treatment response. The ideal tool is robust and non-invasive so that the treatment can be rapidly adjusted or discontinued based on efficacy. Since targeted therapies primarily affect tumor angiogenesis, morphological assessment based on tumor size alone may be insufficient, and other imaging modalities and features may be more helpful in assessing response. This review aims to discuss the biological principles of tumor angiogenesis and the multi-modality imaging evaluation of anti-angiogenic therapeutic responses.
Collapse
Affiliation(s)
- Moataz A. Soliman
- Department of Diagnostic Radiology, Northwestern University, Evanston, IL 60201, USA;
| | - Jeffrey Guccione
- Department of Diagnostic and Interventional Imaging, The University of Texas Health Sciences Center at Houston, Houston, TX 77030, USA;
| | - Anna M. Reiter
- School of Medicine, University of Texas Southwestern, Dallas, TX 75390, USA;
| | - Ahmed W. Moawad
- Department of Diagnostic Radiology, The University of Texas M. D. Anderson Cancer Center, Houston, TX 77030, USA;
| | - Ashley Etchison
- Department of Diagnostic Radiology, Baylor College of Medicine, Houston, TX 76798, USA;
| | - Serageldin Kamel
- Department of Lymphoma and Myeloma, The University of Texas M. D. Anderson Cancer Center, Houston, TX 77030, USA;
| | - Aline D. Khatchikian
- Department of Diagnostic Radiology, McGill University, Montreal, QC H3G 1A4, Canada;
| | - Khaled M. Elsayes
- Department of Diagnostic Radiology, The University of Texas M. D. Anderson Cancer Center, Houston, TX 77030, USA;
- Correspondence:
| |
Collapse
|
3
|
Barbato F, Atzeni S, Batani D, Bleiner D, Boutoux G, Brabetz C, Bradford P, Mancelli D, Neumayer P, Schiavi A, Trela J, Volpe L, Zeraouli G, Woolsey N, Antonelli L. Quantitative phase contrast imaging of a shock-wave with a laser-plasma based X-ray source. Sci Rep 2019; 9:18805. [PMID: 31827132 PMCID: PMC6906500 DOI: 10.1038/s41598-019-55074-1] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2019] [Accepted: 11/06/2019] [Indexed: 12/02/2022] Open
Abstract
X-ray phase contrast imaging (XPCI) is more sensitive to density variations than X-ray absorption radiography, which is a crucial advantage when imaging weakly-absorbing, low-Z materials, or steep density gradients in matter under extreme conditions. Here, we describe the application of a polychromatic X-ray laser-plasma source (duration ~0.5 ps, photon energy >1 keV) to the study of a laser-driven shock travelling in plastic material. The XPCI technique allows for a clear identification of the shock front as well as of small-scale features present during the interaction. Quantitative analysis of the compressed object is achieved using a density map reconstructed from the experimental data.
Collapse
Affiliation(s)
- F Barbato
- Empa, Materials Science and Technology, 8600, Dübendorf, Switzerland. .,Universitè de Bordeaux, CNRS, CEA, CELIA, UMR 5107, F-33405, Talence, France.
| | - S Atzeni
- Dipartimento SBAI, Università di Roma "La Sapienza", 00161, Rome, Italy
| | - D Batani
- Universitè de Bordeaux, CNRS, CEA, CELIA, UMR 5107, F-33405, Talence, France.,National Research Nuclear University MEPhI, Department of Plasma Physics, 115409, Moscow, Russia
| | - D Bleiner
- Empa, Materials Science and Technology, 8600, Dübendorf, Switzerland
| | - G Boutoux
- Universitè de Bordeaux, CNRS, CEA, CELIA, UMR 5107, F-33405, Talence, France
| | - C Brabetz
- GSI Helmholtzzentrum für Schwerionenforschung GmbH, 64291, Darmstadt, Germany
| | - P Bradford
- Department of Physics, York Plasma Institute, University of York, York, YO10 5DD, United Kingdom
| | - D Mancelli
- Universitè de Bordeaux, CNRS, CEA, CELIA, UMR 5107, F-33405, Talence, France.,Donostia International Physics Center (DIPC), 20018, Donostia, Spain
| | - P Neumayer
- GSI Helmholtzzentrum für Schwerionenforschung GmbH, 64291, Darmstadt, Germany
| | - A Schiavi
- Dipartimento SBAI, Università di Roma "La Sapienza", 00161, Rome, Italy
| | - J Trela
- Universitè de Bordeaux, CNRS, CEA, CELIA, UMR 5107, F-33405, Talence, France
| | - L Volpe
- CLPU, Centro de Laseres Pulsados, Building M5, 37185, Villamayor, Salamanca, Spain
| | - G Zeraouli
- CLPU, Centro de Laseres Pulsados, Building M5, 37185, Villamayor, Salamanca, Spain.,Universidad de Salamanca, Patio de Escuelas 1, 37008, Salamanca, Spain
| | - N Woolsey
- Department of Physics, York Plasma Institute, University of York, York, YO10 5DD, United Kingdom
| | - L Antonelli
- Dipartimento SBAI, Università di Roma "La Sapienza", 00161, Rome, Italy.,Department of Physics, York Plasma Institute, University of York, York, YO10 5DD, United Kingdom
| |
Collapse
|
4
|
Cao Y, Zhang M, Ding H, Chen Z, Tang B, Wu T, Xiao B, Duan C, Ni S, Jiang L, Luo Z, Li C, Zhao J, Liao S, Yin X, Fu Y, Xiao T, Lu H, Hu J. Synchrotron radiation micro-tomography for high-resolution neurovascular network morphology investigation. JOURNAL OF SYNCHROTRON RADIATION 2019; 26:607-618. [PMID: 31074423 DOI: 10.1107/s1600577519003060] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/08/2018] [Accepted: 02/27/2019] [Indexed: 06/09/2023]
Abstract
There has been increasing interest in using high-resolution micro-tomography to investigate the morphology of neurovascular networks in the central nervous system, which remain difficult to characterize due to their microscopic size as well as their delicate and complex 3D structure. Synchrotron radiation X-ray imaging, which has emerged as a cutting-edge imaging technology with a high spatial resolution, provides a novel platform for the non-destructive imaging of microvasculature networks at a sub-micrometre scale. When coupled with computed tomography, this technique allows the characterization of the 3D morphology of vasculature. The current review focuses on recent progress in developing synchrotron radiation methodology and its application in probing neurovascular networks, especially the pathological changes associated with vascular abnormalities in various model systems. Furthermore, this tool represents a powerful imaging modality that improves our understanding of the complex biological interactions between vascular function and neuronal activity in both physiological and pathological states.
Collapse
Affiliation(s)
- Yong Cao
- Department of Spine Surgery, Xiangya Hospital, Central South University, Changsha 410008, People's Republic of China
| | - Mengqi Zhang
- Department of Neurology, Xiangya Hospital, Central South University, Changsha 410008, People's Republic of China
| | - Hui Ding
- Department of Neurology, Xiangya Hospital, Central South University, Changsha 410008, People's Republic of China
| | - Zhuohui Chen
- Department of Neurology, Xiangya Hospital, Central South University, Changsha 410008, People's Republic of China
| | - Bin Tang
- Department of Neurology, Xiangya Hospital, Central South University, Changsha 410008, People's Republic of China
| | - Tianding Wu
- Department of Spine Surgery, Xiangya Hospital, Central South University, Changsha 410008, People's Republic of China
| | - Bo Xiao
- Department of Neurology, Xiangya Hospital, Central South University, Changsha 410008, People's Republic of China
| | - Chunyue Duan
- Department of Spine Surgery, Xiangya Hospital, Central South University, Changsha 410008, People's Republic of China
| | - Shuangfei Ni
- Department of Spine Surgery, Xiangya Hospital, Central South University, Changsha 410008, People's Republic of China
| | - Liyuan Jiang
- Department of Spine Surgery, Xiangya Hospital, Central South University, Changsha 410008, People's Republic of China
| | - Zixiang Luo
- Department of Spine Surgery, Xiangya Hospital, Central South University, Changsha 410008, People's Republic of China
| | - Chengjun Li
- Department of Spine Surgery, Xiangya Hospital, Central South University, Changsha 410008, People's Republic of China
| | - Jinyun Zhao
- Department of Spine Surgery, Xiangya Hospital, Central South University, Changsha 410008, People's Republic of China
| | - Shenghui Liao
- School of Information Science and Engineering, Central South University, Changsha 410008, People's Republic of China
| | - Xianzhen Yin
- Center for Drug Delivery System, Shanghai Institute of Materia Medica, Chinese Academy of Sciences, Shanghai 20203, People's Republic of China
| | - Yalan Fu
- Shanghai Synchrotron Radiation Facility/Zhangjiang Lab, Shanghai Advanced Research Institute, Chinese Academy of Sciences, Shanghai 21204, People's Republic of China
| | - Tiqiao Xiao
- Shanghai Synchrotron Radiation Facility/Zhangjiang Lab, Shanghai Advanced Research Institute, Chinese Academy of Sciences, Shanghai 21204, People's Republic of China
| | - Hongbin Lu
- Key Laboratory of Organ Injury, Aging and Regenerative Medicine of Hunan Province, Changsha, Hunan 410008, People's Republic of China
| | - Jianzhong Hu
- Department of Spine Surgery, Xiangya Hospital, Central South University, Changsha 410008, People's Republic of China
| |
Collapse
|
5
|
Larsson JC, Shaker K, Hertz HM. Focused anti-scatter grid for background reduction in x-ray fluorescence tomography. OPTICS LETTERS 2018; 43:2591-2594. [PMID: 29856437 DOI: 10.1364/ol.43.002591] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/13/2018] [Accepted: 04/30/2018] [Indexed: 06/08/2023]
Abstract
X-ray fluorescence (XRF) tomography is an emerging imaging technology with the potential for high spatial resolution molecular imaging. One of the key limitations is the background noise due to Compton scattering since it degrades the signal and limits the sensitivity. In this Letter, we present a linear focused anti-scatter grid that reduces the Compton scattering background. An anti-scatter grid was manufactured and evaluated both experimentally and theoretically with Monte Carlo simulations. The measurements showed a 31% increase in signal-to-background ratio, and simulations of an improved grid showed that this can easily be extended up to >75%. Simulated tomographies using the improved grid show a large improvement in reconstruction quality. The anti-scatter grid will be important for in vivo XRF tomography since the background reduction allows for faster scan times, lower doses, and lower nanoparticle concentrations.
Collapse
|
6
|
Applications of Laboratory-Based Phase-Contrast Imaging Using Speckle Tracking Technique towards High Energy X-Rays. J Imaging 2018. [DOI: 10.3390/jimaging4050069] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
|
7
|
Töpperwien M, Gradl R, Keppeler D, Vassholz M, Meyer A, Hessler R, Achterhold K, Gleich B, Dierolf M, Pfeiffer F, Moser T, Salditt T. Propagation-based phase-contrast x-ray tomography of cochlea using a compact synchrotron source. Sci Rep 2018; 8:4922. [PMID: 29563553 PMCID: PMC5862924 DOI: 10.1038/s41598-018-23144-5] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2017] [Accepted: 03/06/2018] [Indexed: 11/23/2022] Open
Abstract
We demonstrate that phase retrieval and tomographic imaging at the organ level of small animals can be advantageously carried out using the monochromatic radiation emitted by a compact x-ray light source, without further optical elements apart from source and detector. This approach allows to carry out microtomography experiments which - due to the large performance gap with respect to conventional laboratory instruments - so far were usually limited to synchrotron sources. We demonstrate the potential by mapping the functional soft tissue within the guinea pig and marmoset cochlea, including in the latter case an electrical cochlear implant. We show how 3d microanatomical studies without dissection or microscopic imaging can enhance future research on cochlear implants.
Collapse
Affiliation(s)
- Mareike Töpperwien
- Institute for X-Ray Physics, University of Göttingen, Göttingen, Germany.,Center for Nanoscopy and Molecular Physiology of the Brain, Göttingen, Germany
| | - Regine Gradl
- Chair of Biomedical Physics, Department of Physics, Technical University of Munich, Garching, Germany.,Institute for Advanced Study, Technical University of Munich, Garching, Germany.,Munich School of BioEngineering, Technical University of Munich, Garching, Germany
| | - Daniel Keppeler
- Institute for Auditory Neuroscience and InnerEarLab, University Medical Center Göttingen, Göttingen, Germany
| | - Malte Vassholz
- Institute for X-Ray Physics, University of Göttingen, Göttingen, Germany
| | - Alexander Meyer
- InnerEarLab, Department of Otolaryngology, University Medical Center Göttingen, Göttingen, Germany
| | | | - Klaus Achterhold
- Chair of Biomedical Physics, Department of Physics, Technical University of Munich, Garching, Germany.,Munich School of BioEngineering, Technical University of Munich, Garching, Germany
| | - Bernhard Gleich
- Munich School of BioEngineering, Technical University of Munich, Garching, Germany
| | - Martin Dierolf
- Chair of Biomedical Physics, Department of Physics, Technical University of Munich, Garching, Germany.,Munich School of BioEngineering, Technical University of Munich, Garching, Germany
| | - Franz Pfeiffer
- Chair of Biomedical Physics, Department of Physics, Technical University of Munich, Garching, Germany.,Institute for Advanced Study, Technical University of Munich, Garching, Germany.,Munich School of BioEngineering, Technical University of Munich, Garching, Germany.,Department of Diagnostic and Interventional Radiology, Klinikum rechts der Isar, Technical University of Munich, München, Germany
| | - Tobias Moser
- Center for Nanoscopy and Molecular Physiology of the Brain, Göttingen, Germany.,Institute for Auditory Neuroscience and InnerEarLab, University Medical Center Göttingen, Göttingen, Germany.,Bernstein Focus for Neurotechnology, University of Göttingen, Göttingen, Germany
| | - Tim Salditt
- Institute for X-Ray Physics, University of Göttingen, Göttingen, Germany. .,Center for Nanoscopy and Molecular Physiology of the Brain, Göttingen, Germany.
| |
Collapse
|
8
|
Zeller-Plumhoff B, Roose T, Clough GF, Schneider P. Image-based modelling of skeletal muscle oxygenation. J R Soc Interface 2017; 14:rsif.2016.0992. [PMID: 28202595 DOI: 10.1098/rsif.2016.0992] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2016] [Accepted: 01/25/2017] [Indexed: 12/12/2022] Open
Abstract
The supply of oxygen in sufficient quantity is vital for the correct functioning of all organs in the human body, in particular for skeletal muscle during exercise. Disease is often associated with both an inhibition of the microvascular supply capability and is thought to relate to changes in the structure of blood vessel networks. Different methods exist to investigate the influence of the microvascular structure on tissue oxygenation, varying over a range of application areas, i.e. biological in vivo and in vitro experiments, imaging and mathematical modelling. Ideally, all of these methods should be combined within the same framework in order to fully understand the processes involved. This review discusses the mathematical models of skeletal muscle oxygenation currently available that are based upon images taken of the muscle microvasculature in vivo and ex vivo Imaging systems suitable for capturing the blood vessel networks are discussed and respective contrasting methods presented. The review further informs the association between anatomical characteristics in health and disease. With this review we give the reader a tool to understand and establish the workflow of developing an image-based model of skeletal muscle oxygenation. Finally, we give an outlook for improvements needed for measurements and imaging techniques to adequately investigate the microvascular capability for oxygen exchange.
Collapse
Affiliation(s)
- B Zeller-Plumhoff
- Helmholtz-Zentrum für Material- und Küstenforschung, Geesthacht, Germany .,Bioengineering Research Group, Faculty of Engineering and the Environment, University of Southampton, Southampton, UK
| | - T Roose
- Bioengineering Research Group, Faculty of Engineering and the Environment, University of Southampton, Southampton, UK
| | - G F Clough
- Faculty of Medicine, University of Southampton, Southampton, UK
| | - P Schneider
- Bioengineering Research Group, Faculty of Engineering and the Environment, University of Southampton, Southampton, UK
| |
Collapse
|
9
|
Li B, Zhang Y, Wu W, Du G, Cai L, Shi H, Chen S. Neovascularization of hepatocellular carcinoma in a nude mouse orthotopic liver cancer model: a morphological study using X-ray in-line phase-contrast imaging. BMC Cancer 2017; 17:73. [PMID: 28122521 PMCID: PMC5264465 DOI: 10.1186/s12885-017-3073-3] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2016] [Accepted: 01/18/2017] [Indexed: 11/24/2022] Open
Abstract
Background This study aimed to determine whether synchrotron radiation (SR)-based X-ray in-line phase-contrast imaging (IL-PCI) can be used to investigate the morphological characteristics of tumor neovascularization in a liver xenograft animal model. Methods A human hepatocellular carcinoma HCCLM3 xenograft model was established in nude mice. Xenografts were sampled each week for 4 weeks and fixed to analyze tissue characteristics and neovascularization using SR-based X-ray in-line phase contrast computed tomography (IL-XPCT) without any contrast agent. Results The effect of the energy level and object–to-detector distance on phase-contrast difference was in good agreement with the theory of IL-PCI. Boundaries between the tumor and adjacent normal tissues at week 1 were clearly observed in two-dimensional phase contrast projection imaging. A quantitative contrast difference was observed from weeks 1 to 4. Moreover, 3D image reconstruction of hepatocellular carcinoma (HCC) samples showed blood vessels inside the tumor were abnormal. The smallest blood vessels measured approximately 20 μm in diameter. The tumor vascular density initially increased and then decreased gradually over time. The maximum tumor vascular density was 4.29% at week 2. Conclusion IL-XPCT successfully acquired images of neovascularization in HCC xenografts in nude mice.
Collapse
Affiliation(s)
- Beilei Li
- Department of Nuclear Medicine, Zhongshan Hospital, Fudan University, No.180, Fenglin Road, Shanghai, 200032, China.,Shanghai Institute of Medical Imaging, Shanghai, 200032, China
| | - Yiqiu Zhang
- Department of Nuclear Medicine, Zhongshan Hospital, Fudan University, No.180, Fenglin Road, Shanghai, 200032, China.,Shanghai Institute of Medical Imaging, Shanghai, 200032, China
| | - Weizhong Wu
- Liver Cancer Institute, Zhongshan Hospital, Fudan University, Shanghai, 200032, China
| | - Guohao Du
- Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai, 201800, China
| | - Liang Cai
- Department of Nuclear Medicine, Zhongshan Hospital, Fudan University, No.180, Fenglin Road, Shanghai, 200032, China.,Shanghai Institute of Medical Imaging, Shanghai, 200032, China
| | - Hongcheng Shi
- Department of Nuclear Medicine, Zhongshan Hospital, Fudan University, No.180, Fenglin Road, Shanghai, 200032, China.,Shanghai Institute of Medical Imaging, Shanghai, 200032, China
| | - Shaoliang Chen
- Department of Nuclear Medicine, Zhongshan Hospital, Fudan University, No.180, Fenglin Road, Shanghai, 200032, China. .,Shanghai Institute of Medical Imaging, Shanghai, 200032, China.
| |
Collapse
|
10
|
Synchrotron Radiation X-Ray Phase-Contrast Tomography Visualizes Microvasculature Changes in Mice Brains after Ischemic Injury. Neural Plast 2016; 2016:3258494. [PMID: 27563468 PMCID: PMC4983401 DOI: 10.1155/2016/3258494] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2016] [Revised: 06/02/2016] [Accepted: 06/23/2016] [Indexed: 12/15/2022] Open
Abstract
Imaging brain microvasculature is important in plasticity studies of cerebrovascular diseases. Applying contrast agents, traditional μCT and μMRI methods gain imaging contrast for vasculature. The aim of this study is to develop a synchrotron radiation X-ray inline phase-contrast tomography (SRXPCT) method for imaging the intact mouse brain (micro)vasculature in high resolution (~3.7 μm) without contrast agent. A specific preparation protocol was proposed to enhance the phase contrast of brain vasculature by using density difference over gas-tissue interface. The CT imaging system was developed and optimized to obtain 3D brain vasculature of adult male C57BL/6 mice. The SRXPCT method was further applied to investigate the microvasculature changes in mouse brains (n = 14) after 14-day reperfusion from transient middle cerebral artery occlusion (tMCAO). 3D reconstructions of brain microvasculature demonstrated that the branching radius ratio (post- to preinjury) of small vessels (radius < 7.4 μm) in the injury group was significantly smaller than that in the sham group (p < 0.05). This result revealed the active angiogenesis in the recovery brain after stroke. As a high-resolution and contrast-agent-free method, the SRXPCT method demonstrates higher potential in investigations of functional plasticity in cerebrovascular diseases.
Collapse
|
11
|
Cao Y, Yin X, Zhang J, Wu T, Li D, Lu H, Hu J. Visualization of mouse spinal cord intramedullary arteries using phase- and attenuation-contrast tomographic imaging. JOURNAL OF SYNCHROTRON RADIATION 2016; 23:966-974. [PMID: 27359146 DOI: 10.1107/s1600577516006482] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/14/2016] [Accepted: 04/17/2016] [Indexed: 06/06/2023]
Abstract
Many spinal cord circulatory disorders present the substantial involvement of small vessel lesions. The central sulcus arteries supply nutrition to a large part of the spinal cord, and, if not detected early, lesions in the spinal cord will cause irreversible damage to the function of this organ. Thus, early detection of these small vessel lesions could potentially facilitate the effective diagnosis and treatment of these diseases. However, the detection of such small vessels is beyond the capability of current imaging techniques. In this study, an imaging method is proposed and the potential of phase-contrast imaging (PCI)- and attenuation-contrast imaging (ACI)-based synchrotron radiation for high-resolution tomography of intramedullary arteries in mouse spinal cord is validated. The three-dimensional vessel morphology, particularly that of the central sulcus arteries (CSA), detected with these two imaging models was quantitatively analyzed and compared. It was determined that both PCI- and ACI-based synchrotron radiation can be used to visualize the physiological arrangement of the entire intramedullary artery network in the mouse spinal cord in both two dimensions and three dimensions at a high-resolution scale. Additionally, the two-dimensional and three-dimensional vessel morphometric parameter measurements obtained with PCI are similar to the ACI data. Furthermore, PCI allows efficient and direct discrimination of the same branch level of the CSA without contrast agent injection and is expected to provide reliable biological information regarding the intramedullary artery. Compared with ACI, PCI might be a novel imaging method that offers a powerful imaging platform for evaluating pathological changes in small vessels and may also allow better clarification of their role in neurovascular disorders.
Collapse
Affiliation(s)
- Yong Cao
- Department of Spine Surgery, Xiangya Hospital, Central South University, Changsha 410008, People's Republic of China
| | - Xianzhen Yin
- Center for Drug Delivery System, Shanghai Institute of Materia Medica, Chinese Academy of Sciences, Shanghai 20203, People's Republic of China
| | - Jiwen Zhang
- Center for Drug Delivery System, Shanghai Institute of Materia Medica, Chinese Academy of Sciences, Shanghai 20203, People's Republic of China
| | - Tianding Wu
- Department of Spine Surgery, Xiangya Hospital, Central South University, Changsha 410008, People's Republic of China
| | - Dongzhe Li
- Department of Spine Surgery, Xiangya Hospital, Central South University, Changsha 410008, People's Republic of China
| | - Hongbin Lu
- Department of Sports Medicine, Research Centre of Sports Medicine, Xiangya Hospital, Central South University, Changsha 410008, People's Republic of China
| | - Jianzhong Hu
- Department of Spine Surgery, Xiangya Hospital, Central South University, Changsha 410008, People's Republic of China
| |
Collapse
|
12
|
Vassholz M, Koberstein-Schwarz B, Ruhlandt A, Krenkel M, Salditt T. New X-Ray Tomography Method Based on the 3D Radon Transform Compatible with Anisotropic Sources. PHYSICAL REVIEW LETTERS 2016; 116:088101. [PMID: 26967444 DOI: 10.1103/physrevlett.116.088101] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/08/2015] [Indexed: 06/05/2023]
Abstract
In this work, we propose a novel computed tomography (CT) approach for three-dimensional (3D) object reconstruction, based on a generalized tomographic geometry with two-dimensional angular sampling (two angular degrees of freedom). The reconstruction is based on the 3D Radon transform and is compatible with anisotropic beam conditions. This allows isotropic 3D imaging with a source, which can be extended along one direction for increased flux, while high resolution is achieved by a small source size only in the orthogonal direction. This novel scheme for analytical CT is demonstrated by numerical simulations and proof-of-concept experiments. In this way high resolution and coherence along a single direction determines the reconstruction quality of the entire 3D data set, opening up, for example, new opportunities to achieve nanoscale resolution and/or phase contrast with low brilliance sources such as laboratory x-ray or neutron sources.
Collapse
Affiliation(s)
- M Vassholz
- Institut für Röntgenphysik, Georg-August-Universität Göttingen, Friedrich-Hund-Platz 1, 37077 Göttingen, Germany
| | - B Koberstein-Schwarz
- Institut für Röntgenphysik, Georg-August-Universität Göttingen, Friedrich-Hund-Platz 1, 37077 Göttingen, Germany
| | - A Ruhlandt
- Institut für Röntgenphysik, Georg-August-Universität Göttingen, Friedrich-Hund-Platz 1, 37077 Göttingen, Germany
| | - M Krenkel
- Institut für Röntgenphysik, Georg-August-Universität Göttingen, Friedrich-Hund-Platz 1, 37077 Göttingen, Germany
| | - T Salditt
- Institut für Röntgenphysik, Georg-August-Universität Göttingen, Friedrich-Hund-Platz 1, 37077 Göttingen, Germany
| |
Collapse
|
13
|
Tang R, Yan F, Chai WM, Huang W, Fu Y, Yang GY, Chen KM. A novel imaging tool for hepatic portal system using phase contrast technique with hydrogen peroxide-generated O₂ gas. JOURNAL OF SYNCHROTRON RADIATION 2015; 22:1263-1267. [PMID: 26289278 DOI: 10.1107/s1600577515010103] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/27/2015] [Accepted: 05/25/2015] [Indexed: 06/04/2023]
Abstract
The objective of this study was to investigate the potential of hydrogen peroxide-generated oxygen gas-based phase contrast imaging (PCI) for visualizing mouse hepatic portal veins. The O2 gas was made from the reaction between H2O2 and catalase. The gas production was imaged by PCI in real time. The H2O2 was injected into the enteric cavity of the lower sigmoid colon to produce O2 in the submucosal venous plexus. The generated O2 gas could be finally drained into hepatic portal veins. Absorption contrast imaging (ACI) and PCI of O2-filled portal veins were performed and compared. PCI offers high resolution and real-time visualization of the O2 gas production. Compared with O2-based ACI, O2-based PCI significantly enhanced the revealing of the portal vein in vivo. It is concluded that O2-based PCI is a novel and promising imaging modality for future studies of portal venous disorders in mice models.
Collapse
Affiliation(s)
- Rongbiao Tang
- Department of Radiology, Rui Jin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200025, People's Republic of China
| | - Fuhua Yan
- Department of Radiology, Rui Jin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200025, People's Republic of China
| | - Wei Min Chai
- Department of Radiology, Rui Jin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200025, People's Republic of China
| | - Wei Huang
- Department of Radiology, Rui Jin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200025, People's Republic of China
| | - Yanan Fu
- Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201204, People's Republic of China
| | - Guo Yuan Yang
- Neuroscience and Neuroengineering Center, Med-X Research Institute, Shanghai Jiao Tong University, Shanghai 200030, People's Republic of China
| | - Ke Min Chen
- Department of Radiology, Rui Jin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200025, People's Republic of China
| |
Collapse
|
14
|
Zhou T, Zanette I, Zdora MC, Lundström U, Larsson DH, Hertz HM, Pfeiffer F, Burvall A. Speckle-based x-ray phase-contrast imaging with a laboratory source and the scanning technique. OPTICS LETTERS 2015; 40:2822-2825. [PMID: 26076271 DOI: 10.1364/ol.40.002822] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
The speckle-based scanning method for x-ray phase-contrast imaging is implemented with a liquid-metal-jet source. Using the two-dimensional scanning technique, the phase shift introduced by the object is retrieved in both transverse orientations, and the limitations on spatial resolution inherent to the speckle-tracking technique are avoided. This method opens up possibilities of new high-resolution multimodal applications for lab-based phase-contrast x-ray imaging.
Collapse
|
15
|
Dubsky S, Fouras A. Imaging regional lung function: a critical tool for developing inhaled antimicrobial therapies. Adv Drug Deliv Rev 2015; 85:100-9. [PMID: 25819486 DOI: 10.1016/j.addr.2015.03.010] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2014] [Revised: 03/18/2015] [Accepted: 03/20/2015] [Indexed: 12/11/2022]
Abstract
Alterations in regional lung function due to respiratory infection have a significant effect on the deposition of inhaled treatments. This has consequences for treatment effectiveness and hence recovery of lung function. In order to advance our understanding of respiratory infection and inhaled treatment delivery, we must develop imaging techniques that can provide regional functional measurements of the lung. In this review, we explore the role of functional imaging for the assessment of respiratory infection and development of inhaled treatments. We describe established and emerging functional lung imaging methods. The effect of infection on lung function is described, and the link between regional disease, function, and inhaled treatments is discussed. The potential for lung function imaging to provide unique insights into the functional consequences of infection, and its treatment, is also discussed.
Collapse
Affiliation(s)
- Stephen Dubsky
- Department of Mechanical & Aerospace Engineering, Monash University, Victoria 3800, Australia.
| | - Andreas Fouras
- Department of Mechanical & Aerospace Engineering, Monash University, Victoria 3800, Australia.
| |
Collapse
|
16
|
Park H, Yeom E, Seo SJ, Lim JH, Lee SJ. Measurement of real pulsatile blood flow using X-ray PIV technique with CO2 microbubbles. Sci Rep 2015; 5:8840. [PMID: 25744850 DOI: 10.1038/srep08840] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2014] [Accepted: 02/06/2015] [Indexed: 11/09/2022] Open
Abstract
Synchrotron X-ray imaging technique has been used to investigate biofluid flows in a non-destructive manner. This study aims to investigate the feasibility of the X-ray PIV technique with CO2 microbubbles as flow tracer for measurement of pulsatile blood flows under in vivo conditions. The traceability of CO2 microbubbles in a pulsatile flow was demonstrated through in vitro experiment. A rat extracorporeal bypass loop was used by connecting a tube between the abdominal aorta and jugular vein of a rat to obtain hemodynamic information of actual pulsatile blood flows without changing the hemorheological properties. The decrease in image contrast of the surrounding tissue was also investigated for in vivo applications of the proposed technique. This technique could be used to accurately measure whole velocity field information of real pulsatile blood flows and has strong potential for hemodynamic diagnosis of cardiovascular diseases.
Collapse
Affiliation(s)
- Hanwook Park
- Center for Biofluid and Biomimic Research, Department of Mechanical Engineering, Pohang University of Science and Technology (POSTECH), Pohang, 790-784, South Korea
| | - Eunseop Yeom
- Center for Biofluid and Biomimic Research, Department of Mechanical Engineering, Pohang University of Science and Technology (POSTECH), Pohang, 790-784, South Korea
| | - Seung-Jun Seo
- Industrial Technology Convergence Center, Pohang Accelerator Laboratory, POSTECH, Pohang, 790-784, South Korea
| | - Jae-Hong Lim
- Industrial Technology Convergence Center, Pohang Accelerator Laboratory, POSTECH, Pohang, 790-784, South Korea
| | - Sang-Joon Lee
- Center for Biofluid and Biomimic Research, Department of Mechanical Engineering, Pohang University of Science and Technology (POSTECH), Pohang, 790-784, South Korea
| |
Collapse
|
17
|
Zhang M, Peng G, Sun D, Xie Y, Xia J, Long H, Hu K, Xiao B. Synchrotron radiation imaging is a powerful tool to image brain microvasculature. Med Phys 2014; 41:031907. [PMID: 24593725 DOI: 10.1118/1.4865784] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023] Open
Abstract
Synchrotron radiation (SR) imaging is a powerful experimental tool for micrometer-scale imaging of microcirculation in vivo. This review discusses recent methodological advances and findings from morphological investigations of cerebral vascular networks during several neurovascular pathologies. In particular, it describes recent developments in SR microangiography for real-time assessment of the brain microvasculature under various pathological conditions in small animal models. It also covers studies that employed SR-based phase-contrast imaging to acquire 3D brain images and provide detailed maps of brain vasculature. In addition, a brief introduction of SR technology and current limitations of SR sources are described in this review. In the near future, SR imaging could transform into a common and informative imaging modality to resolve subtle details of cerebrovascular function.
Collapse
Affiliation(s)
- Mengqi Zhang
- Department of Neurology, Xiangya Hospital, Central South University, Changsha, Hunan 410008, People's Republic of China
| | - Guanyun Peng
- Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800, People's Republic of China
| | - Danni Sun
- Department of Neurology, Xiangya Hospital, Central South University, Changsha, Hunan 410008, People's Republic of China
| | - Yuanyuan Xie
- Department of Neurology, Xiangya Hospital, Central South University, Changsha, Hunan 410008, People's Republic of China
| | - Jian Xia
- Department of Neurology, Xiangya Hospital, Central South University, Changsha, Hunan 410008, People's Republic of China
| | - Hongyu Long
- Department of Neurology, Xiangya Hospital, Central South University, Changsha, Hunan 410008, People's Republic of China
| | - Kai Hu
- Department of Neurology, Xiangya Hospital, Central South University, Changsha, Hunan 410008, People's Republic of China
| | - Bo Xiao
- Department of Neurology, Xiangya Hospital, Central South University, Changsha, Hunan 410008, People's Republic of China
| |
Collapse
|
18
|
Lee SJ, Park HW, Jung SY. Usage of CO2 microbubbles as flow-tracing contrast media in X-ray dynamic imaging of blood flows. JOURNAL OF SYNCHROTRON RADIATION 2014; 21:1160-1166. [PMID: 25178007 DOI: 10.1107/s1600577514013423] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/21/2014] [Accepted: 06/09/2014] [Indexed: 06/03/2023]
Abstract
X-ray imaging techniques have been employed to visualize various biofluid flow phenomena in a non-destructive manner. X-ray particle image velocimetry (PIV) was developed to measure velocity fields of blood flows to obtain hemodynamic information. A time-resolved X-ray PIV technique that is capable of measuring the velocity fields of blood flows under real physiological conditions was recently developed. However, technical limitations still remained in the measurement of blood flows with high image contrast and sufficient biocapability. In this study, CO2 microbubbles as flow-tracing contrast media for X-ray PIV measurements of biofluid flows was developed. Human serum albumin and CO2 gas were mechanically agitated to fabricate CO2 microbubbles. The optimal fabricating conditions of CO2 microbubbles were found by comparing the size and amount of microbubbles fabricated under various operating conditions. The average size and quantity of CO2 microbubbles were measured by using a synchrotron X-ray imaging technique with a high spatial resolution. The quantity and size of the fabricated microbubbles decrease with increasing speed and operation time of the mechanical agitation. The feasibility of CO2 microbubbles as a flow-tracing contrast media was checked for a 40% hematocrit blood flow. Particle images of the blood flow were consecutively captured by the time-resolved X-ray PIV system to obtain velocity field information of the flow. The experimental results were compared with a theoretically amassed velocity profile. Results show that the CO2 microbubbles can be used as effective flow-tracing contrast media in X-ray PIV experiments.
Collapse
Affiliation(s)
- Sang Joon Lee
- Center for Biofluid and Biomimic Research, Department of Mechanical Engineering, Pohang University of Science and Technology (POSTECH), Pohang 790-784, Republic of Korea
| | - Han Wook Park
- Center for Biofluid and Biomimic Research, Department of Mechanical Engineering, Pohang University of Science and Technology (POSTECH), Pohang 790-784, Republic of Korea
| | - Sung Yong Jung
- Hyundai Heavy Industries, Ulsan 682-792, Republic of Korea
| |
Collapse
|
19
|
|
20
|
Lundström U, Westermark UK, Larsson DH, Burvall A, Arsenian Henriksson M, Hertz HM. X-ray phase contrast with injected gas for tumor microangiography. Phys Med Biol 2014; 59:2801-11. [PMID: 24801363 DOI: 10.1088/0031-9155/59/11/2801] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/17/2023]
Abstract
We show that the microvasculature of mouse tumors can be visualized using propagation-based phase-contrast x-ray imaging with gas as the contrast agent. The large density difference over the gas-tissue interface provides high contrast, allowing the imaging of small-diameter blood vessels with relatively short exposure times and low dose using a compact liquid-metal-jet x-ray source. The method investigated is applied to tumors (E1A/Ras-transformed mouse embryonic fibroblasts) grown in mouse ears, demonstrating sub-15-µm-diameter imaging of their blood vessels. The exposure time for a 2D projection image is a few seconds and a full tomographic 3D map takes some minutes. The method relies on the strength of the vasculature to withstand the gas pressure. Given that tumor vessels are known to be more fragile than normal vessels, we investigate the tolerance of the vasculature of 12 tumors to gas injection and find that a majority withstand 200 mbar pressures, enough to fill 12-µm-diameter vessels with gas. A comparison of the elasticity of tumorous and non-tumorous vessels supports the assumption of tumor vessels being more fragile. Finally, we conclude that the method has the potential to be extended to the imaging of 15 µm vessels in thick tissue, including mouse imaging, making it of interest for, e.g., angiogenesis research.
Collapse
Affiliation(s)
- U Lundström
- Biomedical and X-Ray Physics, Department of Applied Physics, KTH Royal Institute of Technology/Albanova, SE-10691 Stockholm, Sweden
| | | | | | | | | | | |
Collapse
|
21
|
Hertz HM, Larsson JC, Lundström U, Larsson DH, Vogt C. Laboratory x-ray fluorescence tomography for high-resolution nanoparticle bio-imaging. OPTICS LETTERS 2014; 39:2790-2793. [PMID: 24784104 DOI: 10.1364/ol.39.002790] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
We demonstrate that nanoparticle x-ray fluorescence computed tomography in mouse-sized objects can be performed with very high spatial resolution at acceptable dose and exposure times with a compact laboratory system. The method relies on the combination of the 24 keV line-emission from a high-brightness liquid-metal-jet x-ray source, pencil-beam-forming x-ray optics, photon-counting energy-dispersive detection, and carefully matched (Mo) nanoparticles. Phantom experiments and simulations show that the arrangement significantly reduces Compton background and allows 100 μm detail imaging at dose and exposure times compatible with small-animal experiments. The method provides a possible path to in vivo molecular x-ray imaging at sub-100 μm resolution in mice.
Collapse
|
22
|
Zhou T, Lundström U, Thüring T, Rutishauser S, Larsson DH, Stampanoni M, David C, Hertz HM, Burvall A. Comparison of two x-ray phase-contrast imaging methods with a microfocus source. OPTICS EXPRESS 2013; 21:30183-30195. [PMID: 24514597 DOI: 10.1364/oe.21.030183] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
We present a comparison for high-resolution imaging with a laboratory source between grating-based (GBI) and propagation-based (PBI) x-ray phase-contrast imaging. The comparison is done through simulations and experiments using a liquid-metal-jet x-ray microfocus source. Radiation doses required for detection in projection images are simulated as a function of the diameter of a cylindrical sample. Using monochromatic radiation, simulations show a lower dose requirement for PBI for small object features and a lower dose for GBI for larger object features. Using polychromatic radiation, such as that from a laboratory microfocus source, experiments and simulations show a lower dose requirement for PBI for a large range of feature sizes. Tested on a biological sample, GBI shows higher noise levels than PBI, but its advantage of quantitative refractive index reconstruction for multi-material samples becomes apparent.
Collapse
|
23
|
Zhou T, Lundström U, Larsson DH, Hertz HM, Burvall A. Low-dose phase-contrast X-ray imaging: a comparison of two methods. ACTA ACUST UNITED AC 2013. [DOI: 10.1088/1742-6596/463/1/012041] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
24
|
Larsson DH, Lundström U, Westermark UK, Arsenian Henriksson M, Burvall A, Hertz HM. First application of liquid-metal-jet sources for small-animal imaging: high-resolution CT and phase-contrast tumor demarcation. Med Phys 2013; 40:021909. [PMID: 23387757 DOI: 10.1118/1.4788661] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023] Open
Abstract
PURPOSE Small-animal studies require images with high spatial resolution and high contrast due to the small scale of the structures. X-ray imaging systems for small animals are often limited by the microfocus source. Here, the authors investigate the applicability of liquid-metal-jet x-ray sources for such high-resolution small-animal imaging, both in tomography based on absorption and in soft-tissue tumor imaging based on in-line phase contrast. METHODS The experimental arrangement consists of a liquid-metal-jet x-ray source, the small-animal object on a rotating stage, and an imaging detector. The source-to-object and object-to-detector distances are adjusted for the preferred contrast mechanism. Two different liquid-metal-jet sources are used, one circulating a Ga∕In∕Sn alloy and the other an In∕Ga alloy for higher penetration through thick tissue. Both sources are operated at 40-50 W electron-beam power with ∼7 μm x-ray spots, providing high spatial resolution in absorption imaging and high spatial coherence for the phase-contrast imaging. RESULTS High-resolution absorption imaging is demonstrated on mice with CT, showing 50 μm bone details in the reconstructed slices. High-resolution phase-contrast soft-tissue imaging shows clear demarcation of mm-sized tumors at much lower dose than is required in absorption. CONCLUSIONS This is the first application of liquid-metal-jet x-ray sources for whole-body small-animal x-ray imaging. In absorption, the method allows high-resolution tomographic skeletal imaging with potential for significantly shorter exposure times due to the power scalability of liquid-metal-jet sources. In phase contrast, the authors use a simple in-line arrangement to show distinct tumor demarcation of few-mm-sized tumors. This is, to their knowledge, the first small-animal tumor visualization with a laboratory phase-contrast system.
Collapse
Affiliation(s)
- Daniel H Larsson
- Department of Applied Physics, KTH Royal Institute of Technology, Stockholm, Sweden.
| | | | | | | | | | | |
Collapse
|
25
|
Ahn S, Jung SY, Lee SJ. Gold nanoparticle contrast agents in advanced X-ray imaging technologies. Molecules 2013; 18:5858-90. [PMID: 23685939 PMCID: PMC6270207 DOI: 10.3390/molecules18055858] [Citation(s) in RCA: 75] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2013] [Revised: 04/30/2013] [Accepted: 05/14/2013] [Indexed: 02/07/2023] Open
Abstract
Recently, there has been significant progress in the field of soft- and hard-X-ray imaging for a wide range of applications, both technically and scientifically, via developments in sources, optics and imaging methodologies. While one community is pursuing extensive applications of available X-ray tools, others are investigating improvements in techniques, including new optics, higher spatial resolutions and brighter compact sources. For increased image quality and more exquisite investigation on characteristic biological phenomena, contrast agents have been employed extensively in imaging technologies. Heavy metal nanoparticles are excellent absorbers of X-rays and can offer excellent improvements in medical diagnosis and X-ray imaging. In this context, the role of gold (Au) is important for advanced X-ray imaging applications. Au has a long-history in a wide range of medical applications and exhibits characteristic interactions with X-rays. Therefore, Au can offer a particular advantage as a tracer and a contrast enhancer in X-ray imaging technologies by sensing the variation in X-ray attenuation in a given sample volume. This review summarizes basic understanding on X-ray imaging from device set-up to technologies. Then this review covers recent studies in the development of X-ray imaging techniques utilizing gold nanoparticles (AuNPs) and their relevant applications, including two- and three-dimensional biological imaging, dynamical processes in a living system, single cell-based imaging and quantitative analysis of circulatory systems and so on. In addition to conventional medical applications, various novel research areas have been developed and are expected to be further developed through AuNP-based X-ray imaging technologies.
Collapse
Affiliation(s)
- Sungsook Ahn
- Biofluid and Biomimic Research Center, Pohang University of Science and Technology, Pohang 790-784, Korea
| | - Sung Yong Jung
- Department of Mechanical Engineering, Pohang University of Science and Technology, Pohang 790-784, Korea
| | - Sang Joon Lee
- Biofluid and Biomimic Research Center, Pohang University of Science and Technology, Pohang 790-784, Korea
- Department of Mechanical Engineering, Pohang University of Science and Technology, Pohang 790-784, Korea
| |
Collapse
|
26
|
Cardiac Micro-PET-CT. CURRENT CARDIOVASCULAR IMAGING REPORTS 2013. [DOI: 10.1007/s12410-012-9188-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
27
|
Shirai M, Schwenke DO, Tsuchimochi H, Umetani K, Yagi N, Pearson JT. Synchrotron radiation imaging for advancing our understanding of cardiovascular function. Circ Res 2013; 112:209-21. [PMID: 23287456 DOI: 10.1161/circresaha.111.300096] [Citation(s) in RCA: 58] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
Synchrotron radiation (SR) is increasingly being used for micro-level and nano-level functional imaging in in vivo animal experiments. This review focuses on the methodology that enables repeated and regional assessment of vessel internal diameter and flow in the resistance vessels of different organ systems. In particular, SR absorption microangiography approaches offer unique opportunities for real-time in vivo vascular imaging in small animals, even during dynamic motion of the heart and lungs. We also describe recent progress in the translation of multiple phase-contrast imaging techniques from ex vivo to in vivo small-animal studies. Furthermore, we also review the utility of SR for multiple pinpoint (dimensions 0.2×0.2 mm) assessments of myocardial function at the cross-bridge level in different regions of the heart using small-angle X-ray scattering, resulting from increases in SR flux at modern facilities. Finally, we present cases for the use of complementary SR approaches to study cardiovascular function, particularly the pathological changes associated with disease using small-animal models.
Collapse
Affiliation(s)
- Mikiyasu Shirai
- National Cerebral and Cardiovascular Center Research Institute, Suita, Japan.
| | | | | | | | | | | |
Collapse
|
28
|
Duan J, Hu C, Chen H. High-resolution micro-CT for morphologic and quantitative assessment of the sinusoid in human cavernous hemangioma of the liver. PLoS One 2013; 8:e53507. [PMID: 23308240 PMCID: PMC3538536 DOI: 10.1371/journal.pone.0053507] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2012] [Accepted: 11/30/2012] [Indexed: 01/25/2023] Open
Abstract
Hepatic sinusoid plays a vital role in human cavernous hemangioma of the liver (CHL), and its morphologic investigation facilitates the understanding of microcirculation mechanism and pathological change of CHL. However, precise anatomical view of the hepatic sinusoid has been limited by the resolution and contrast available from existing imaging techniques. While liver biopsy has traditionally been the reliable method for the assessment of hepatic sinusoids, the invasiveness and sampling error are its inherent limitations. In this study, imaging of CHL samples was performed using in-line phase-contrast imaging (ILPCI) technique with synchrotron radiation. ILPCI allowed clear visualization of soft tissues and revealed structural details that were invisible to conventional radiography. Combining the computed tomography (CT) technique, ILPCI-CT was used to acquire the high-resolution micro-CT images of CHL, and three dimensional (3D) microstructures of hepatic sinusoids were provided for the morphologic depiction and quantitative assessment. Our study demonstrated that ILPCI-CT could substantially improve the radiographic contrast of CHL tissues in vitro with no contrast agent. ILPCI-CT yielded high-resolution micro-CT image of CHL sample at the micron scale, corresponding to information on actual structures revealed at histological section. The 3D visualization provided an excellent view of the hepatic sinusoid. The accurate view of individual hepatic sinusoid was achieved. The valuable morphological parameters of hepatic sinusoids, such as thrombi, diameters, surface areas and volumes, were measured. These parameters were of great importance in the evaluation of CHL, and they provided quantitative descriptors that characterized anatomical properties and pathological features of hepatic sinusoids. The results highlight the high degree of sensitivity of the ILPCI-CT technique and demonstrate the feasibility of accurate visualization of hepatic sinusoids. Moreover, there is a correlation between the CHL and the size or morphology of hepatic sinusoids, which offers a potential use in noninvasive study and analysis of CHL.
Collapse
Affiliation(s)
- Jinghao Duan
- College of Biomedical Engineering, Tianjin Medical University, Tianjin, China
| | - Chunhong Hu
- College of Biomedical Engineering, Tianjin Medical University, Tianjin, China
- * E-mail:
| | - Hua Chen
- Department of Hepatobiliary Surgery, Tianjin Medical University Cancer Hospital, Tianjin, China
| |
Collapse
|
29
|
Bravin A, Coan P, Suortti P. X-ray phase-contrast imaging: from pre-clinical applications towards clinics. Phys Med Biol 2012; 58:R1-35. [PMID: 23220766 DOI: 10.1088/0031-9155/58/1/r1] [Citation(s) in RCA: 393] [Impact Index Per Article: 32.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Abstract
Phase-contrast x-ray imaging (PCI) is an innovative method that is sensitive to the refraction of the x-rays in matter. PCI is particularly adapted to visualize weakly absorbing details like those often encountered in biology and medicine. In past years, PCI has become one of the most used imaging methods in laboratory and preclinical studies: its unique characteristics allow high contrast 3D visualization of thick and complex samples even at high spatial resolution. Applications have covered a wide range of pathologies and organs, and are more and more often performed in vivo. Several techniques are now available to exploit and visualize the phase-contrast: propagation- and analyzer-based, crystal and grating interferometry and non-interferometric methods like the coded aperture. In this review, covering the last five years, we will give an overview of the main theoretical and experimental developments and of the important steps performed towards the clinical implementation of PCI.
Collapse
Affiliation(s)
- Alberto Bravin
- European Synchrotron Radiation Facility, 6 rue Horowitz, 38043 Grenoble Cedex, France.
| | | | | |
Collapse
|
30
|
Lundström U, Larsson DH, Burvall A, Scott L, Westermark UK, Wilhelm M, Arsenian Henriksson M, Hertz HM. X-ray phase-contrast CO2angiography for sub-10 μm vessel imaging. Phys Med Biol 2012; 57:7431-41. [DOI: 10.1088/0031-9155/57/22/7431] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|