Ito D, Numano T, Habe T, Okuda S, Nozaki T, Jinzaki M. Fast abdominal magnetic resonance elastography with simultaneous encoding of three-dimensional displacements. Magn Reson Imaging 2024; 108:138-145. [PMID: 38360120 DOI: 10.1016/j.mri.2024.02.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2023] [Revised: 02/07/2024] [Accepted: 02/11/2024] [Indexed: 02/17/2024]
Abstract
Three-dimensional (3D) magnetic resonance elastography (MRE) is more accurate than two-dimensional (2D) MRE; however, it requires long-term acquisition. This study aimed to reduce the acquisition time of abdominal 3D MRE using a new sample interval modulation (short-SLIM) approach that can acquire all three motions faster while reducing the prolongation of echo time and flow compensation. To this end, two types of phantom studies and an in vivo test of the liver in three healthy volunteers were performed to compare the performances of conventional spin-echo echo-planar (SE-EPI) MRE, conventional SLIM and short-SLIM. One phantom study measured the mean amplitude and shear modulus within the overall region of a homogeneous phantom by changing the mechanical vibration power to assess the robustness to the lowered phase-to-noise ratio in short-SLIM. The other measured the mean shear modulus in the stiff and background materials of a phantom with an embedded stiffer rod to assess the performance of short-SLIM for complex wave patterns with wave interference. The Spearman's rank correlation coefficient was used to assess similarity of elastograms in the rod-embedded phantom and liver between methods. The results of the phantom study changing the vibration power indicated that there was little difference between conventional MRE and short-SLIM. Moreover, the elastogram pattern and the mean shear modulus in the rod-embedded phantom in conventional SLIM and short-SLIM did not change for conventional MRE; the liver test also showed a small difference between the acquisition techniques. This study demonstrates that short-SLIM can provide MRE results comparable to those of conventional MRE. Short-SLIM can reduce the total acquisition time by a factor of 2.25 compared to conventional 3D MRE time, leading to an improvement in the accuracy of shear modulus estimation by suppressing the patient movements.
Collapse
Affiliation(s)
- Daiki Ito
- Office of Radiation Technology, Keio University Hospital, 35, Shinanomachi, Shinjuku-ku, Tokyo 160-8582, Japan; Department of Radiological Sciences, Graduate School of Human Health Sciences, Tokyo Metropolitan University, 7-2-10, Higashiogu, Arakawa-ku, Tokyo 116-8551, Japan.
| | - Tomokazu Numano
- Department of Radiological Sciences, Graduate School of Human Health Sciences, Tokyo Metropolitan University, 7-2-10, Higashiogu, Arakawa-ku, Tokyo 116-8551, Japan; Health Research Institute, National Institute of Advanced Industrial Science and Technology, 1-2-1, Namiki, Tsukuba-shi, Ibaraki 305-8564, Japan
| | - Tetsushi Habe
- Office of Radiation Technology, Keio University Hospital, 35, Shinanomachi, Shinjuku-ku, Tokyo 160-8582, Japan
| | - Shigeo Okuda
- Department of Diagnostic Radiology, National Tokyo Medical Center, 2-5-1, Higashigaoka, Meguro-ku, Tokyo 152-8902, Japan; Department of Radiology, Keio University School of Medicine, 35, Shinanomachi, Shinjuku-ku, Tokyo 160-8582, Japan
| | - Taiki Nozaki
- Department of Radiology, Keio University School of Medicine, 35, Shinanomachi, Shinjuku-ku, Tokyo 160-8582, Japan
| | - Masahiro Jinzaki
- Department of Radiology, Keio University School of Medicine, 35, Shinanomachi, Shinjuku-ku, Tokyo 160-8582, Japan
| |
Collapse
|
2
|
Shan X, Yang J, Xu P, Hu L, Ge H. Deep neural networks for magnetic resonance elastography acceleration in thermal ablation monitoring. Med Phys 2022; 49:1803-1813. [PMID: 35061250 DOI: 10.1002/mp.15471] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2021] [Revised: 12/03/2021] [Accepted: 12/31/2021] [Indexed: 11/12/2022] Open
Abstract
PURPOSE To develop a deep neural network for accelerating magnetic resonance elastography (MRE) acquisition, to validate the ability to generate reliable MRE results with the down-sampled k-space data, and to demonstrate the feasibility of the proposed method in monitoring the stiffness changes during thermal ablation in a phantom study. MATERIALS AND METHODS MRE scans were performed with 60 Hz excitation on porcine ex-vivo liver gel phantoms in a 0.36T MRI scanner to generate the training dataset. The acquisition protocol was based on a spin-echo MRE pulse sequence with tailored motion-sensitive gradients to reduce echo time (TE). A U-Net based deep neural network was developed and trained to interpolate the missing data from down-sampled k-space. We calculated the errors of 80 sets magnitude/phase images reconstructed from the zero-filled, compressive sensing (CS) and deep learning (DL) method for comparison. The peak signal-to-noise rate (PSNR) and structural similarity (SSIM) of the magnitude/phase images were also calculated for comparison. The stiffness changes were recorded before, during, and after ablation. The mean stiffness values over the region of interest (ROI) were compared between the elastograms reconstructed from the fully-sampled k-space and interpolated k-space after thermal ablation. RESULTS The mean absolute error (MAE), PSNR, and SSIM of the proposed deep learning approach were significantly better than the results from the zero-filled method (p<0.0001) and CS (p<0.0001). The stiffness changes before and after thermal ablation assessed by the proposed approach (before: 7.7±1.1 kPa, after: 11.9±4.0 kPa, 4.2-kPa increase) gave close agreement with the values calculated from the fully-sampled data (before: 8.0±1.0 kPa, after: 12.6±4.2 kPa, 4.6-kPa increase). In contrast, the stiffness changes computed from the zero-filled method (before: 4.9±1.4 kPa, after: 5.6±2.8 kPa, 0.7-kPa increase) were substantially underestimated. CONCLUSION This study demonstrated the capability of the proposed deep learning method for rapid MRE acquisition and provided a promising solution for monitoring the MRI-guided thermal ablation. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Xiang Shan
- School of Medical Imaging, Xuzhou Medical University, Xuzhou, Jiangsu, China
| | - Jinying Yang
- Laboratory Center for Information Science, University of Science and Technology of China, Hefei, Anhui, China
| | - Peng Xu
- Department of Radiology, Affiliated Hospital of Xuzhou Medical University, Xuzhou, Jiangsu, China
| | - Liangliang Hu
- School of Instrument Science and Opto-electronics Engineering, Hefei University of Technology, Hefei, Anhui, China
| | - Haitao Ge
- School of Medical Imaging, Xuzhou Medical University, Xuzhou, Jiangsu, China
| |
Collapse
|
3
|
Zampini MA, Guidetti M, Royston TJ, Klatt D. Measuring viscoelastic parameters in Magnetic Resonance Elastography: a comparison at high and low magnetic field intensity. J Mech Behav Biomed Mater 2021; 120:104587. [PMID: 34034077 DOI: 10.1016/j.jmbbm.2021.104587] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2020] [Revised: 04/21/2021] [Accepted: 05/08/2021] [Indexed: 12/21/2022]
Abstract
Magnetic Resonance Elastography (MRE) is a non-invasive imaging technique which involves motion-encoding MRI for the estimation of the shear viscoelastic properties of soft tissues through the study of shear wave propagation. The technique has been found informative for disease diagnosis, as well as for monitoring of the effects of therapies. The development of MRE and its validation have been supported by the use of tissue-mimicking phantoms. In this paper we present our new MRE protocol using a low magnetic field tabletop MRI device at 0.5 T and sinusoidal uniaxial excitation in a geometrical focusing condition. Results obtained for gelatin are compared to those previously obtained using high magnetic field MRE at 11.7 T. A multi-frequency investigation is also provided via a comparison of commonly used rheological models: Maxwell, Springpot, Voigt, Zener, Jeffrey, fractional Voigt and fractional Zener. Complex shear modulus values were comparable when processed from images acquired with the tabletop low field scanner and the high field scanner. This study serves as a validation of the presented tabletop MRE protocol and paves the way for MRE experiments on ex-vivo tissue samples in both normal and pathological conditions.
Collapse
Affiliation(s)
- Marco Andrea Zampini
- University of Illinois at Chicago, Department of Bioengineering, University of Illinois at Chicago, Chicago, IL, 60607, USA; MR Solutions Ltd, Ashbourne House, Old Portsmouth Rd, Guildford, United Kingdom; Bio-Imaging Lab, Department of Biomedical Sciences, University of Antwerp, Universiteitsplein 1, Wilrijk, Belgium.
| | - Martina Guidetti
- University of Illinois at Chicago, Department of Bioengineering, University of Illinois at Chicago, Chicago, IL, 60607, USA
| | - Thomas J Royston
- University of Illinois at Chicago, Department of Bioengineering, University of Illinois at Chicago, Chicago, IL, 60607, USA
| | - Dieter Klatt
- University of Illinois at Chicago, Department of Bioengineering, University of Illinois at Chicago, Chicago, IL, 60607, USA
| |
Collapse
|
4
|
Majumdar S, Klatt D. Longitudinal study of sub-regional cerebral viscoelastic properties of 5XFAD Alzheimer's disease mice using multifrequency MR elastography. Magn Reson Med 2021; 86:405-414. [PMID: 33604900 DOI: 10.1002/mrm.28709] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2020] [Revised: 01/12/2021] [Accepted: 01/13/2021] [Indexed: 02/06/2023]
Abstract
PURPOSE To study sub-regional, longitudinal changes occurring inside brains of 5XFAD mice, an Alzheimer's disease (AD) model, based on viscoelastic parameters derived using MR elastography and their spatial variation. METHODS Female 5XFAD and non-transgenic B6SJLF1/J mice as controls (n = 9 for both groups) were used for the study. Scans were performed inside a 9.4T preclinical MRI scanner using SampLe Interval Modulation-magnetic resonance elastography (SLIM-MRE). Experiments were performed at ages 2, 4, and 6 mo, and by using three actuation frequencies: 900, 1000, and 1100 Hz. Multifrequency dual elasto-visco (MDEV) reconstruction was used to combine 3D multifrequency MRE data and calculate magnitude G ∗ , and phase angle φ, of the complex shear modulus G ∗ . Mean values were measured for the overall brain and sub-regions associated with the early onset of AD, to check for the effect of aging and mouse model. Spatial coefficient of variation (CV) of both parameters across different age-groups were analyzed. RESULTS G ∗ and φ values reduced with age for overall brain in 5XFAD mice with significant difference in mean G ∗ between 5XFAD and control mice at 6 mo (P = .029). Analyzing values from the hippocampal region highlighted drop in mean G ∗ and φ values. The CV of G ∗ inside hippocampus enabled differentiation at 4 mo with it being significantly lower in 5XFAD mice (P = .0007). CONCLUSION Multifrequency 3D MRE revealed longitudinal viscoelastic changes in 5XFAD mice and the CV of G ∗ in brain sub-regions may qualify as biomarker for early diagnosis of AD.
Collapse
Affiliation(s)
- Shreyan Majumdar
- Richard and Loan Hill Department of Bioengineering, University of Illinois, Chicago, Illinois, USA
| | - Dieter Klatt
- Richard and Loan Hill Department of Bioengineering, University of Illinois, Chicago, Illinois, USA
| |
Collapse
|
5
|
Manduca A, Bayly PJ, Ehman RL, Kolipaka A, Royston TJ, Sack I, Sinkus R, Van Beers BE. MR elastography: Principles, guidelines, and terminology. Magn Reson Med 2020; 85:2377-2390. [PMID: 33296103 DOI: 10.1002/mrm.28627] [Citation(s) in RCA: 99] [Impact Index Per Article: 24.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2020] [Revised: 10/20/2020] [Accepted: 11/09/2020] [Indexed: 12/13/2022]
Abstract
Magnetic resonance elastography (MRE) is a phase contrast-based MRI technique that can measure displacement due to propagating mechanical waves, from which material properties such as shear modulus can be calculated. Magnetic resonance elastography can be thought of as quantitative, noninvasive palpation. It is increasing in clinical importance, has become widespread in the diagnosis and staging of liver fibrosis, and additional clinical applications are being explored. However, publications have reported MRE results using many different parameters, acquisition techniques, processing methods, and varied nomenclature. The diversity of terminology can lead to confusion (particularly among clinicians) about the meaning of and interpretation of MRE results. This paper was written by the MRE Guidelines Committee, a group formalized at the first meeting of the ISMRM MRE Study Group, to clarify and move toward standardization of MRE nomenclature. The purpose of this paper is to (1) explain MRE terminology and concepts to those not familiar with them, (2) define "good practices" for practitioners of MRE, and (3) identify opportunities to standardize terminology, to avoid confusion.
Collapse
Affiliation(s)
- Armando Manduca
- Physiology and Biomedical Engineering, Mayo Clinic, Rochester, Minnesota, USA
| | - Philip J Bayly
- Mechanical Engineering and Materials Science, Washington University in St. Louis, St. Louis, Missouri, USA
| | - Richard L Ehman
- Physiology and Biomedical Engineering, Mayo Clinic, Rochester, Minnesota, USA
| | - Arunark Kolipaka
- Department of Radiology, Ohio State University, Columbus, Ohio, USA
| | - Thomas J Royston
- Department of Bioengineering, University of Illinois at Chicago, Chicago, Illinois, USA
| | - Ingolf Sack
- Charité-Universitätsmedizin Berlin, Berlin, Germany
| | - Ralph Sinkus
- Imaging Sciences & Biomedical Engineering, Kings College London, London, United Kingdom
| | | |
Collapse
|
6
|
Nia HT, Datta M, Seano G, Zhang S, Ho WW, Roberge S, Huang P, Munn LL, Jain RK. In vivo compression and imaging in mouse brain to measure the effects of solid stress. Nat Protoc 2020; 15:2321-2340. [PMID: 32681151 PMCID: PMC11412114 DOI: 10.1038/s41596-020-0328-2] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2018] [Accepted: 04/06/2020] [Indexed: 02/07/2023]
Abstract
We recently developed an in vivo compression device that simulates the solid mechanical forces exerted by a growing tumor on the surrounding brain tissue and delineates the physical versus biological effects of a tumor. This device, to our knowledge the first of its kind, can recapitulate the compressive forces on the cerebellar cortex from primary (e.g., glioblastoma) and metastatic (e.g., breast cancer) tumors, as well as on the cerebellum from tumors such as medulloblastoma and ependymoma. We adapted standard transparent cranial windows normally used for intravital imaging studies in mice to include a turnable screw for controlled compression (acute or chronic) and decompression of the cerebral cortex. The device enables longitudinal imaging of the compressed brain tissue over several weeks or months as the screw is progressively extended against the brain tissue to recapitulate tumor growth-induced solid stress. The cranial window can be simply installed on the mouse skull according to previously established methods, and the screw mechanism can be readily manufactured in-house. The total time for construction and implantation of the in vivo compressive cranial window is <1 h (per mouse). This technique can also be used to study a variety of other diseases or disorders that present with abnormal solid masses in the brain, including cysts and benign growths.
Collapse
Affiliation(s)
- Hadi T Nia
- Edwin L. Steele Laboratories, Department of Radiation Oncology, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
- Department of Biomedical Engineering, Boston University, Boston, MA, USA
| | - Meenal Datta
- Edwin L. Steele Laboratories, Department of Radiation Oncology, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
| | - Giorgio Seano
- Edwin L. Steele Laboratories, Department of Radiation Oncology, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
- Tumor Microenvironment Laboratory, Institut Curie Research Center, Paris-Saclay University, PSL Research University, Inserm U1021, CNRS UMR3347, Orsay, France
| | - Sue Zhang
- Department of Biomedical Engineering, Boston University, Boston, MA, USA
| | - William W Ho
- Edwin L. Steele Laboratories, Department of Radiation Oncology, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
- Department of Chemical Engineering, Massachusetts Institute of Technology, Cambridge, MA, USA
| | - Sylvie Roberge
- Edwin L. Steele Laboratories, Department of Radiation Oncology, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
| | - Peigen Huang
- Edwin L. Steele Laboratories, Department of Radiation Oncology, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
| | - Lance L Munn
- Edwin L. Steele Laboratories, Department of Radiation Oncology, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
| | - Rakesh K Jain
- Edwin L. Steele Laboratories, Department of Radiation Oncology, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA.
| |
Collapse
|
7
|
Majeed W, Kalra P, Kolipaka A. Simultaneous multislice rapid magnetic resonance elastography of the liver. NMR IN BIOMEDICINE 2020; 33:e4252. [PMID: 31971301 PMCID: PMC7286422 DOI: 10.1002/nbm.4252] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/12/2018] [Revised: 12/09/2019] [Accepted: 12/10/2019] [Indexed: 06/10/2023]
Abstract
To design and validate a rapid Simultaneous Multi-slice (SMS) Magnetic Resonance Elastography technique (MRE), which combines SMS acquisition, in-plane undersampling and an existing rapid Magnetic Resonance Elastography (MREr) scheme to allow accelerated data acquisition in healthy volunteers and comparison against MREr. SMS-MREr sequence was developed by incorporating SMS acquisition scheme into an existing MREr sequence that accelerates MRE acquisition by acquiring data during opposite phases of mechanical vibrations. The MREr sequence accelerated MRE acquisition by acquiring data during opposite phases of mechanical vibrations. Liver MRE was performed on 23 healthy subjects using MREr and SMS-MREr sequences, and mean stiffness values were obtained for manually drawn regions of interest. Linear correlation and agreement between MREr- and SMS-MREr-based stiffness values were investigated. SMS-MREr reduced the scan time by half relative to MREr, and allowed acquisition of four-slice MRE data in a single 17-second breath-hold. Visual comparison suggested agreement between MREr and SMS-MREr elastograms. A Pearson's correlation of 0.93 was observed between stiffness values derived from MREr and SMS-MREr. Bland-Altman analysis demonstrated good agreement, with -0.08 kPa mean bias and narrow limits of agreement (95% CI: 0.23 to -0.39 kPa) between stiffness values obtained using MREr and SMS-MREr. SMS can be combined with other fast MRE approaches to achieve further acceleration. This pushes the limit on the acceleration that can be achieved in MRE acquisition, and makes it possible to conduct liver MRE exams in a single breath-hold.
Collapse
Affiliation(s)
- Waqas Majeed
- Department of RadiologyThe Ohio State University Wexner Medical CenterColumbusOhioUSA
| | - Prateek Kalra
- Department of RadiologyThe Ohio State University Wexner Medical CenterColumbusOhioUSA
| | - Arunark Kolipaka
- Department of RadiologyThe Ohio State University Wexner Medical CenterColumbusOhioUSA
- Department of Biomedical EngineeringThe Ohio State UniversityColumbusOhioUSA
- Department of Internal Medicine ‐ Division of CardiologyThe Ohio State University Wexner Medical CenterColumbusOhioUSA
| |
Collapse
|
8
|
Bigot M, Chauveau F, Amaz C, Sinkus R, Beuf O, Lambert SA. The apparent mechanical effect of isolated amyloid-β and α-synuclein aggregates revealed by multi-frequency MRE. NMR IN BIOMEDICINE 2020; 33:e4174. [PMID: 31696585 DOI: 10.1002/nbm.4174] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/22/2019] [Revised: 08/11/2019] [Accepted: 08/13/2019] [Indexed: 06/10/2023]
Abstract
Several biological processes are involved in dementia, and fibrillar aggregation of misshaped endogenous proteins appears to be an early hallmark of neurodegenerative disease. A recently developed means of studying neurodegenerative diseases is magnetic resonance elastography (MRE), an imaging technique investigating the mechanical properties of tissues. Although mechanical changes associated with these diseases have been detected, the specific signal of fibrils has not yet been isolated in clinical or preclinical studies. The current study aims to exploit the fractal-like properties of fibrils to separate them from nonaggregated proteins using a multi-frequency MRE power law exponent in a phantom study. Two types of fibril, α-synuclein (α-Syn) and amyloid-β (Aβ), and a nonaggregated protein, bovine serum albumin, used as control, were incorporated in a dedicated nondispersive agarose phantom. Elastography was performed at multiple frequencies between 400 and 1200 Hz. After 3D-direct inversion, storage modulus (G'), phase angle (ϕ), wave speed and the power law exponent (y) were computed. No significant changes in G' and ϕ were detected. Both α-Syn and Aβ inclusions showed significantly higher y values than control inclusions (P = 0.005) but did not differ between each other. The current phantom study highlighted a specific biomechanical effect of α-Syn and Aβ aggregates, which was better captured with the power law exponent derived from multi-frequency MRE than with single frequency-derived parameters.
Collapse
Affiliation(s)
- Mathilde Bigot
- Université de Lyon, INSA-Lyon, Université Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, Lyon, France
| | - Fabien Chauveau
- Université de Lyon, Lyon Neuroscience Research Center, CNRS UMR 5292, INSERM U1028, Université Claude Bernard Lyon 1, Lyon, France
| | - Camille Amaz
- Centre D'Investigation Clinique de Lyon, Hôpital Louis Pradel, Hospices Civils de Lyon, Lyon, France
| | - Ralph Sinkus
- INSERM U 1148, Laboratory of Vascular Translational Science, X. Bichat Hospital University Paris Diderot, Paris, France
| | - Olivier Beuf
- Université de Lyon, INSA-Lyon, Université Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, Lyon, France
| | - Simon A Lambert
- Université de Lyon, INSA-Lyon, Université Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, Lyon, France
| |
Collapse
|
9
|
Bigot M, Chauveau F, Beuf O, Lambert SA. Magnetic Resonance Elastography of Rodent Brain. Front Neurol 2018; 9:1010. [PMID: 30538670 PMCID: PMC6277573 DOI: 10.3389/fneur.2018.01010] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2018] [Accepted: 11/08/2018] [Indexed: 12/28/2022] Open
Abstract
Magnetic resonance elastography (MRE) is a non-invasive imaging technique, using the propagation of mechanical waves as a probe to palpate biological tissues. It consists in three main steps: production of shear waves within the tissue; encoding subsequent tissue displacement in magnetic resonance images; and extraction of mechanical parameters based on dedicated reconstruction methods. These three steps require an acoustic-frequency mechanical actuator, magnetic resonance imaging acquisition, and a post-processing tool for which no turnkey technology is available. The aim of the present review is to outline the state of the art of reported set-ups to investigate rodent brain mechanical properties. The impact of experimental conditions in dimensioning the set-up (wavelength and amplitude of the propagated wave, spatial resolution, and signal-to-noise ratio of the acquisition) on the accuracy and precision of the extracted parameters is discussed, as well as the influence of different imaging sequences, scanners, electromagnetic coils, and reconstruction algorithms. Finally, the performance of MRE in demonstrating viscoelastic differences between structures constituting the physiological rodent brain, and the changes in brain parameters under pathological conditions, are summarized. The recently established link between biomechanical properties of the brain as obtained on MRE and structural factors assessed by histology is also studied. This review intends to give an accessible outline on how to conduct an elastography experiment, and on the potential of the technique in providing valuable information for neuroscientists.
Collapse
Affiliation(s)
- Mathilde Bigot
- Univ. Lyon, INSA-Lyon, Université Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, Lyon, France
| | - Fabien Chauveau
- Univ. Lyon, Lyon Neuroscience Research Center, CNRS UMR 5292, INSERM U1028, Univ. Lyon 1, Lyon, France
| | - Olivier Beuf
- Univ. Lyon, INSA-Lyon, Université Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, Lyon, France
| | - Simon A Lambert
- Univ. Lyon, INSA-Lyon, Université Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, Lyon, France
| |
Collapse
|
10
|
Bayly PV, Garbow JR. Pre-clinical MR elastography: Principles, techniques, and applications. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2018; 291:73-83. [PMID: 29705042 PMCID: PMC5943171 DOI: 10.1016/j.jmr.2018.01.004] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/15/2017] [Accepted: 01/07/2018] [Indexed: 05/09/2023]
Abstract
Magnetic resonance elastography (MRE) is a method for measuring the mechanical properties of soft tissue in vivo, non-invasively, by imaging propagating shear waves in the tissue. The speed and attenuation of waves depends on the elastic and dissipative properties of the underlying material. Tissue mechanical properties are essential for biomechanical models and simulations, and may serve as markers of disease, injury, development, or recovery. MRE is already established as a clinical technique for detecting and characterizing liver disease. The potential of MRE for diagnosing or characterizing disease in other organs, including brain, breast, and heart is an active research area. Studies involving MRE in the pre-clinical setting, in phantoms and artificial biomaterials, in the mouse, and in other mammals, are critical to the development of MRE as a robust, reliable, and useful modality.
Collapse
Affiliation(s)
- P V Bayly
- Mechanical Engineering and Materials Science, Washington University in Saint Louis, MO, USA.
| | - J R Garbow
- Radiology, Washington University School of Medicine, Saint Louis, MO, USA
| |
Collapse
|