1
|
Rezaei B, Tay ZW, Mostufa S, Manzari ON, Azizi E, Ciannella S, Moni HEJ, Li C, Zeng M, Gómez-Pastora J, Wu K. Magnetic nanoparticles for magnetic particle imaging (MPI): design and applications. NANOSCALE 2024; 16:11802-11824. [PMID: 38809214 DOI: 10.1039/d4nr01195c] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2024]
Abstract
Recent advancements in medical imaging have brought forth various techniques such as magnetic resonance imaging (MRI), computed tomography (CT), positron emission tomography (PET), and ultrasound, each contributing to improved diagnostic capabilities. Most recently, magnetic particle imaging (MPI) has become a rapidly advancing imaging modality with profound implications for medical diagnostics and therapeutics. By directly detecting the magnetization response of magnetic tracers, MPI surpasses conventional imaging modalities in sensitivity and quantifiability, particularly in stem cell tracking applications. Herein, this comprehensive review explores the fundamental principles, instrumentation, magnetic nanoparticle tracer design, and applications of MPI, offering insights into recent advancements and future directions. Novel tracer designs, such as zinc-doped iron oxide nanoparticles (Zn-IONPs), exhibit enhanced performance, broadening MPI's utility. Spatial encoding strategies, scanning trajectories, and instrumentation innovations are elucidated, illuminating the technical underpinnings of MPI's evolution. Moreover, integrating machine learning and deep learning methods enhances MPI's image processing capabilities, paving the way for more efficient segmentation, quantification, and reconstruction. The potential of superferromagnetic iron oxide nanoparticle chains (SFMIOs) as new MPI tracers further advanced the imaging quality and expanded clinical applications, underscoring the promising future of this emerging imaging modality.
Collapse
Affiliation(s)
- Bahareh Rezaei
- Department of Electrical and Computer Engineering, Texas Tech University, Lubbock, TX 79409, USA.
| | - Zhi Wei Tay
- National Institute of Advanced Industrial Science and Technology (AIST), Health and Medical Research Institute, Tsukuba, Ibaraki 305-8564, Japan
| | - Shahriar Mostufa
- Department of Electrical and Computer Engineering, Texas Tech University, Lubbock, TX 79409, USA.
| | - Omid Nejati Manzari
- Department of Electrical and Computer Engineering, Texas Tech University, Lubbock, TX 79409, USA.
| | - Ebrahim Azizi
- Department of Electrical and Computer Engineering, Texas Tech University, Lubbock, TX 79409, USA.
| | - Stefano Ciannella
- Department of Chemical Engineering, Texas Tech University, Lubbock, TX 79409, USA
| | - Hur-E-Jannat Moni
- Department of Chemical Engineering, Texas Tech University, Lubbock, TX 79409, USA
| | - Changzhi Li
- Department of Electrical and Computer Engineering, Texas Tech University, Lubbock, TX 79409, USA.
| | - Minxiang Zeng
- Department of Chemical Engineering, Texas Tech University, Lubbock, TX 79409, USA
| | | | - Kai Wu
- Department of Electrical and Computer Engineering, Texas Tech University, Lubbock, TX 79409, USA.
| |
Collapse
|
2
|
Pacheco MO, Gerzenshtein IK, Stoppel WL, Rinaldi-Ramos CM. Advances in Vascular Diagnostics using Magnetic Particle Imaging (MPI) for Blood Circulation Assessment. Adv Healthc Mater 2024:e2400612. [PMID: 38879782 DOI: 10.1002/adhm.202400612] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2024] [Revised: 05/11/2024] [Indexed: 06/29/2024]
Abstract
Rapid and accurate assessment of conditions characterized by altered blood flow, cardiac blood pooling, or internal bleeding is crucial for diagnosing and treating various clinical conditions. While widely used imaging modalities such as magnetic resonance imaging (MRI), computed tomography (CT), and ultrasound offer unique diagnostic advantages, they fall short for specific indications due to limited penetration depth and prolonged acquisition times. Magnetic particle imaging (MPI), an emerging tracer-based technique, holds promise for blood circulation assessments, potentially overcoming existing limitations with reduction in background signals and high temporal and spatial resolution, below the millimeter scale. Successful imaging of blood pooling and impaired flow necessitates tracers with diverse circulation half-lives optimized for MPI signal generation. Recent MPI tracers show potential in imaging cardiovascular complications, vascular perforations, ischemia, and stroke. The impressive temporal resolution and penetration depth also position MPI as an excellent modality for real-time vessel perfusion imaging via functional MPI (fMPI). This review summarizes advancements in optimized MPI tracers for imaging blood circulation and analyzes the current state of pre-clinical applications. This work discusses perspectives on standardization required to transition MPI from a research endeavor to clinical implementation and explore additional clinical indications that may benefit from the unique capabilities of MPI.
Collapse
Affiliation(s)
- Marisa O Pacheco
- Chemical Engineering, University of Florida, Gainesville, FL, 32611, USA
| | | | - Whitney L Stoppel
- Chemical Engineering, University of Florida, Gainesville, FL, 32611, USA
- J. Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, Gainesville, FL, 32611, USA
| | - Carlos M Rinaldi-Ramos
- Chemical Engineering, University of Florida, Gainesville, FL, 32611, USA
- J. Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, Gainesville, FL, 32611, USA
| |
Collapse
|
3
|
Xie X, Zhai J, Zhou X, Guo Z, Lo PC, Zhu G, Chan KWY, Yang M. Magnetic Particle Imaging: From Tracer Design to Biomedical Applications in Vasculature Abnormality. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2024; 36:e2306450. [PMID: 37812831 DOI: 10.1002/adma.202306450] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/03/2023] [Revised: 09/14/2023] [Indexed: 10/11/2023]
Abstract
Magnetic particle imaging (MPI) is an emerging non-invasive tomographic technique based on the response of magnetic nanoparticles (MNPs) to oscillating drive fields at the center of a static magnetic gradient. In contrast to magnetic resonance imaging (MRI), which is driven by uniform magnetic fields and projects the anatomic information of the subjects, MPI directly tracks and quantifies MNPs in vivo without background signals. Moreover, it does not require radioactive tracers and has no limitations on imaging depth. This article first introduces the basic principles of MPI and important features of MNPs for imaging sensitivity, spatial resolution, and targeted biodistribution. The latest research aiming to optimize the performance of MPI tracers is reviewed based on their material composition, physical properties, and surface modifications. While the unique advantages of MPI have led to a series of promising biomedical applications, recent development of MPI in investigating vascular abnormalities in cardiovascular and cerebrovascular systems, and cancer are also discussed. Finally, recent progress and challenges in the clinical translation of MPI are discussed to provide possible directions for future research and development.
Collapse
Affiliation(s)
- Xulin Xie
- Department of Precision Diagnostic and Therapeutic Technology, City University of Hong Kong Shenzhen Futian Research Institute, Shenzhen, 518057, China
- Department of Biomedical Sciences, and Tung Biomedical Sciences Centre, City University of Hong Kong, 83 Tat Chee Avenue, Kowloon, Hong Kong SAR, 999077, China
| | - Jiao Zhai
- Department of Precision Diagnostic and Therapeutic Technology, City University of Hong Kong Shenzhen Futian Research Institute, Shenzhen, 518057, China
- Department of Biomedical Sciences, and Tung Biomedical Sciences Centre, City University of Hong Kong, 83 Tat Chee Avenue, Kowloon, Hong Kong SAR, 999077, China
| | - Xiaoyu Zhou
- Department of Precision Diagnostic and Therapeutic Technology, City University of Hong Kong Shenzhen Futian Research Institute, Shenzhen, 518057, China
- Department of Biomedical Sciences, and Tung Biomedical Sciences Centre, City University of Hong Kong, 83 Tat Chee Avenue, Kowloon, Hong Kong SAR, 999077, China
| | - Zhengjun Guo
- Department of Biomedical Sciences, and Tung Biomedical Sciences Centre, City University of Hong Kong, 83 Tat Chee Avenue, Kowloon, Hong Kong SAR, 999077, China
- Department of Oncology, the Second Affiliated Hospital of Chongqing Medical University, Chongqing, 400010, China
| | - Pui-Chi Lo
- Department of Precision Diagnostic and Therapeutic Technology, City University of Hong Kong Shenzhen Futian Research Institute, Shenzhen, 518057, China
- Department of Biomedical Sciences, and Tung Biomedical Sciences Centre, City University of Hong Kong, 83 Tat Chee Avenue, Kowloon, Hong Kong SAR, 999077, China
| | - Guangyu Zhu
- Department of Chemistry, City University of Hong Kong, Hong Kong SAR, 999077, China
| | - Kannie W Y Chan
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong SAR, 999077, China
| | - Mengsu Yang
- Department of Precision Diagnostic and Therapeutic Technology, City University of Hong Kong Shenzhen Futian Research Institute, Shenzhen, 518057, China
- Department of Biomedical Sciences, and Tung Biomedical Sciences Centre, City University of Hong Kong, 83 Tat Chee Avenue, Kowloon, Hong Kong SAR, 999077, China
| |
Collapse
|
4
|
Bai S, Zhang XD, Zou YQ, Lin YX, Liu ZY, Li KW, Huang P, Yoshida T, Liu YL, Li MS, Zhang W, Wang XJ, Zhang M, Du C. Development of high-efficiency superparamagnetic drug delivery system with MPI imaging capability. Front Bioeng Biotechnol 2024; 12:1382085. [PMID: 38572358 PMCID: PMC10987818 DOI: 10.3389/fbioe.2024.1382085] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2024] [Accepted: 03/11/2024] [Indexed: 04/05/2024] Open
Abstract
In this study, a high-efficiency superparamagnetic drug delivery system was developed for preclinical treatment of bladder cancer in small animals. Two types of nanoparticles with magnetic particle imaging (MPI) capability, i.e., single- and multi-core superparamagnetic iron oxide nanoparticles (SPIONs), were selected and coupled with bladder anti-tumor drugs by a covalent coupling scheme. Owing to the minimal particle size, magnetic field strengths of 270 mT with a gradient of 3.2 T/m and 260 mT with a gradient of 3.7 T/m were found to be necessary to reach an average velocity of 2 mm/s for single- and multi-core SPIONs, respectively. To achieve this, a method of constructing an in vitro magnetic field for drug delivery was developed based on hollow multi-coils arranged coaxially in close rows, and magnetic field simulation was used to study the laws of the influence of the coil structure and parameters on the magnetic field. Using this method, a magnetic drug delivery system of single-core SPIONs was developed for rabbit bladder therapy. The delivery system consisted of three coaxially and equidistantly arranged coils with an inner diameter of Φ50 mm, radial height of 85 mm, and width of 15 mm that were positioned in close proximity to each other. CCK8 experimental results showed that the three types of drug-coupled SPION killed tumor cells effectively. By adjusting the axial and radial positions of the rabbit bladder within the inner hole of the delivery coil structure, the magnetic drugs injected could undergo two-dimensional delivery motions and were delivered and aggregated to the specified target location within 12 s, with an aggregation range of about 5 mm × 5 mm. In addition, the SPION distribution before and after delivery was imaged using a home-made open-bore MPI system that could realistically reflect the physical state. This study contributes to the development of local, rapid, and precise drug delivery and the visualization of this process during cancer therapy, and further research on MPI/delivery synchronization technology is planned for the future.
Collapse
Affiliation(s)
- Shi Bai
- Department of Information Engineering, Shenyang University of Technology, Shenyang, China
| | - Xiao-dan Zhang
- Department of Information Engineering, Shenyang University of Technology, Shenyang, China
| | - Yu-qi Zou
- Department of Information Engineering, Shenyang University of Technology, Shenyang, China
| | - Yu-xi Lin
- Department of Information Engineering, Shenyang University of Technology, Shenyang, China
| | - Zhi-yao Liu
- Department of Information Engineering, Shenyang University of Technology, Shenyang, China
| | - Ke-wen Li
- Department of Information Engineering, Shenyang University of Technology, Shenyang, China
| | - Ping Huang
- Department of Information Engineering, Shenyang University of Technology, Shenyang, China
| | - Takashi Yoshida
- Department of Electrical Engineering, Kyushu University, Fukuoka, Japan
| | - Yi-li Liu
- Department of Urology, Fourth Affiliated Hospital of China Medical University, Shenyang, China
| | - Ming-shan Li
- Department of Urology, Fourth Affiliated Hospital of China Medical University, Shenyang, China
| | - Wei Zhang
- Department of Oncology, General Hospital of Northern Theater Command, Shenyang, China
| | - Xiao-ju Wang
- Department of Foreign Languages, Liaoning Vocational and Technical College of Economics, Shenyang, China
| | - Min Zhang
- First Affiliated Hospital, China Medical University, Shenyang, China
| | - Cheng Du
- Department of Oncology, General Hospital of Northern Theater Command, Shenyang, China
| |
Collapse
|
5
|
Feng X, Gao P, Li Y, Hui H, Jiang J, Xie F, Tian J. First magnetic particle imaging to assess pulmonary vascular leakage in vivo in the acutely injured and fibrotic lung. Bioeng Transl Med 2024; 9:e10626. [PMID: 38435827 PMCID: PMC10905553 DOI: 10.1002/btm2.10626] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2023] [Revised: 10/17/2023] [Accepted: 11/14/2023] [Indexed: 03/05/2024] Open
Abstract
Increased pulmonary vascular permeability is a characteristic feature of lung injury. However, there are no established methods that allow the three-dimensional visualization and quantification of pulmonary vascular permeability in vivo. Evans blue extravasation test and total protein test of bronchoalveolar lavage fluid (BALF) are permeability assays commonly used in research settings. However, they lack the ability to identify the spatial and temporal heterogeneity of endothelial barrier disruption, which is typical in lung injuries. Magnetic resonance (MR) and near-infrared (NIR) imaging have been proposed to image pulmonary permeability, but suffer from limited sensitivity and penetration depth, respectively. In this study, we report the first use of magnetic particle imaging (MPI) to assess pulmonary vascular leakage noninvasively in vivo in mice. A dextran-coated superparamagnetic iron oxide (SPIO), synomag®, was employed as the imaging tracer, and pulmonary SPIO extravasation was imaged and quantified to evaluate the vascular leakage. Animal models of acute lung injury and pulmonary fibrosis (PF) were used to validate the proposed method. MPI sensitively detected the SPIO extravasation in both acutely injured and fibrotic lungs in vivo, which was confirmed by ex vivo imaging and Prussian blue staining. Moreover, 3D MPI illustrated the spatial heterogeneity of vascular leakage, which correlated well with CT findings. Based on the in vivo 3D MPI images, we defined the SPIO extravasation index (SEI) to quantify the vascular leakage. A significant increase in SEI was observed in the injured lungs, in consistent with the results obtained via ex vivo permeability assays. Overall, our results demonstrate that 3D quantitative MPI serves as a useful tool to examine pulmonary vascular integrity in vivo, which shows promise for future clinical translation.
Collapse
Affiliation(s)
- Xin Feng
- CAS Key Laboratory of Molecular Imaging, Beijing Key Laboratory of Molecular ImagingInstitute of Automation, Chinese Academy of SciencesBeijingChina
- School of Artificial Intelligence, University of Chinese Academy of SciencesBeijingChina
| | - Pengli Gao
- School of Biological Science and Medicine Engineering & School of Engineering Medicine, Beihang UniversityBeijingChina
- Key Laboratory of Big Data‐Based Precision Medicine (Beihang University)Ministry of Industry and Information TechnologyBeijingChina
- School of Engineering Medicine, Beihang UniversityBeijingChina
| | - Yabin Li
- College of Pulmonary and Critical Care Medicine, Chinese PLA General HospitalBeijingChina
| | - Hui Hui
- CAS Key Laboratory of Molecular Imaging, Beijing Key Laboratory of Molecular ImagingInstitute of Automation, Chinese Academy of SciencesBeijingChina
- School of Artificial Intelligence, University of Chinese Academy of SciencesBeijingChina
| | - Jingying Jiang
- Key Laboratory of Big Data‐Based Precision Medicine (Beihang University)Ministry of Industry and Information TechnologyBeijingChina
- School of Engineering Medicine, Beihang UniversityBeijingChina
| | - Fei Xie
- College of Pulmonary and Critical Care Medicine, Chinese PLA General HospitalBeijingChina
| | - Jie Tian
- CAS Key Laboratory of Molecular Imaging, Beijing Key Laboratory of Molecular ImagingInstitute of Automation, Chinese Academy of SciencesBeijingChina
- Key Laboratory of Big Data‐Based Precision Medicine (Beihang University)Ministry of Industry and Information TechnologyBeijingChina
- School of Engineering Medicine, Beihang UniversityBeijingChina
| |
Collapse
|
6
|
Remmo A, Kosch O, Kampen L, Ludwig A, Wiekhorst F, Löwa N. Counting cells in motion by quantitative real-time magnetic particle imaging. Sci Rep 2024; 14:4253. [PMID: 38378785 PMCID: PMC10879211 DOI: 10.1038/s41598-024-54784-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2023] [Accepted: 02/16/2024] [Indexed: 02/22/2024] Open
Abstract
Magnetic Particle Imaging (MPI) is an advanced and powerful imaging modality for visualization and quantitative real-time detection of magnetic nanoparticles (MNPs). This opens the possibility of tracking cells in vivo once they have been loaded by MNPs. Imaging modalities such as optical imaging, X-ray computed tomography (CT), positron emission tomography (PET), single photon emission computed tomography (SPECT), and magnetic resonance imaging (MRI) face limitations, from depth of penetration and radiation exposure to resolution and quantification accuracy. MPI addresses these challenges, enabling radiation-free tracking of MNP-loaded cells with precise quantification. However, the real-time tracking of MNP-loaded cells with MPI has not been demonstrated yet. This study establishes real-time quantitative tracking of MNP-loaded cells. Therefore, THP-1 monocytes were loaded with three different MNP systems, including the MPI gold standard Resovist and Synomag. The real-time MPI experiments reveal different MPI resolution behaviors of the three MNP systems after cellular uptake. Real-time quantitative imaging was achieved by time-resolved cell number determination and comparison with the number of inserted cells. About 95% of the inserted cells were successfully tracked in a controlled phantom environment. These results underline the potential of MPI for real-time investigation of cell migration and interaction with tissue in vivo.
Collapse
Affiliation(s)
- Amani Remmo
- Physikalisch-Technische Bundesanstalt, Abbestr. 2-12, 10587, Berlin, Germany.
| | - Olaf Kosch
- Physikalisch-Technische Bundesanstalt, Abbestr. 2-12, 10587, Berlin, Germany
| | - Lena Kampen
- Department of Cardiology, Angiology and Intensive Care Medicine, Deutsches Herzzentrum der Charité, Charitéplatz 1, 10117, Berlin, Germany
- Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universitätzu Berlin, Charitéplatz 1, 10117, Berlin, Germany
- DZHK (German Centre for Cardiovascular Research), Partner Site Berlin, Berlin, Germany
| | - Antje Ludwig
- Department of Cardiology, Angiology and Intensive Care Medicine, Deutsches Herzzentrum der Charité, Charitéplatz 1, 10117, Berlin, Germany
- Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universitätzu Berlin, Charitéplatz 1, 10117, Berlin, Germany
- DZHK (German Centre for Cardiovascular Research), Partner Site Berlin, Berlin, Germany
| | - Frank Wiekhorst
- Physikalisch-Technische Bundesanstalt, Abbestr. 2-12, 10587, Berlin, Germany
| | - Norbert Löwa
- Physikalisch-Technische Bundesanstalt, Abbestr. 2-12, 10587, Berlin, Germany
| |
Collapse
|
7
|
Nigam S, Mohapatra J, Makela AV, Hayat H, Rodriguez JM, Sun A, Kenyon E, Redman NA, Spence D, Jabin G, Gu B, Ashry M, Sempere LF, Mitra A, Li J, Chen J, Wei GW, Bolin S, Etchebarne B, Liu JP, Contag CH, Wang P. Shape Anisotropy-Governed High-Performance Nanomagnetosol for In Vivo Magnetic Particle Imaging of Lungs. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2024; 20:e2305300. [PMID: 37735143 PMCID: PMC10842459 DOI: 10.1002/smll.202305300] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/25/2023] [Revised: 08/24/2023] [Indexed: 09/23/2023]
Abstract
Caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), coronavirus disease 2019 (COVID-19) has shown extensive lung manifestations in vulnerable individuals, putting lung imaging and monitoring at the forefront of early detection and treatment. Magnetic particle imaging (MPI) is an imaging modality, which can bring excellent contrast, sensitivity, and signal-to-noise ratios to lung imaging for the development of new theranostic approaches for respiratory diseases. Advances in MPI tracers would offer additional improvements and increase the potential for clinical translation of MPI. Here, a high-performance nanotracer based on shape anisotropy of magnetic nanoparticles is developed and its use in MPI imaging of the lung is demonstrated. Shape anisotropy proves to be a critical parameter for increasing signal intensity and resolution and exceeding those properties of conventional spherical nanoparticles. The 0D nanoparticles exhibit a 2-fold increase, while the 1D nanorods have a > 5-fold increase in signal intensity when compared to VivoTrax. Newly designed 1D nanorods displayed high signal intensities and excellent resolution in lung images. A spatiotemporal lung imaging study in mice revealed that this tracer offers new opportunities for monitoring disease and guiding intervention.
Collapse
Affiliation(s)
- Saumya Nigam
- Precision Health Program, Michigan State University, East Lansing, MI, 48824, USA
- Department of Radiology, College of Human Medicine, Michigan State University, East Lansing, MI, 48824, USA
| | - Jeotikanta Mohapatra
- Department of Physics, The University of Texas at Arlington, Arlington, TX, 76019, USA
| | - Ashley V Makela
- Institute for Quantitative Health Science and Engineering (IQ), Michigan State University, East Lansing, MI, 48824, USA
- Department of Biomedical Engineering, College of Engineering, Michigan State University, East Lansing, MI, 48824, USA
| | - Hanaan Hayat
- Precision Health Program, Michigan State University, East Lansing, MI, 48824, USA
- Department of Radiology, College of Human Medicine, Michigan State University, East Lansing, MI, 48824, USA
| | - Jessi Mercedes Rodriguez
- Precision Health Program, Michigan State University, East Lansing, MI, 48824, USA
- Department of Radiology, College of Human Medicine, Michigan State University, East Lansing, MI, 48824, USA
- Human Biology Program, College of Natural Science, Michigan State University, East Lansing, MI, 48824, USA
| | - Aixia Sun
- Precision Health Program, Michigan State University, East Lansing, MI, 48824, USA
- Department of Radiology, College of Human Medicine, Michigan State University, East Lansing, MI, 48824, USA
| | - Elizabeth Kenyon
- Precision Health Program, Michigan State University, East Lansing, MI, 48824, USA
- Department of Radiology, College of Human Medicine, Michigan State University, East Lansing, MI, 48824, USA
| | - Nathan A Redman
- Institute for Quantitative Health Science and Engineering (IQ), Michigan State University, East Lansing, MI, 48824, USA
- Department of Biomedical Engineering, College of Engineering, Michigan State University, East Lansing, MI, 48824, USA
| | - Dana Spence
- Institute for Quantitative Health Science and Engineering (IQ), Michigan State University, East Lansing, MI, 48824, USA
- Department of Biomedical Engineering, College of Engineering, Michigan State University, East Lansing, MI, 48824, USA
| | - George Jabin
- Department of Physics, The University of Texas at Arlington, Arlington, TX, 76019, USA
| | - Bin Gu
- Department of Obstetrics, Gynecology and Reproductive Sciences, College of Human Medicine, Michigan State University, East Lansing, MI, 48824, USA
| | - Mohamed Ashry
- Precision Health Program, Michigan State University, East Lansing, MI, 48824, USA
- Department of Radiology, College of Human Medicine, Michigan State University, East Lansing, MI, 48824, USA
| | - Lorenzo F Sempere
- Precision Health Program, Michigan State University, East Lansing, MI, 48824, USA
- Department of Radiology, College of Human Medicine, Michigan State University, East Lansing, MI, 48824, USA
| | - Arijit Mitra
- Department of Materials Science and Engineering, National Cheng Kung University, Tainan City, 701, Taiwan
| | - Jinxing Li
- Institute for Quantitative Health Science and Engineering (IQ), Michigan State University, East Lansing, MI, 48824, USA
- Department of Biomedical Engineering, College of Engineering, Michigan State University, East Lansing, MI, 48824, USA
| | - Jiahui Chen
- Department of Mathematics, College of Natural Science, Michigan State U, niversity, East Lansing, MI, 48824, USA
| | - Guo-Wei Wei
- Department of Mathematics, College of Natural Science, Michigan State U, niversity, East Lansing, MI, 48824, USA
- Department of Electrical and Computer Engineering, College of Engineering, Michigan State University, East Lansing, MI, 48824, USA
- Department of Biochemistry and Molecular Biology, College of Natural Science, Michigan State University, East Lansing, MI, 48824, USA
| | - Steven Bolin
- Department of Pathobiology and Diagnostic Investigation, College of Veterinary Medicine, Michigan State University, East Lansing, MI, 48824, USA
| | - Brett Etchebarne
- Osteopathic Medical Specialties, College of Osteopathic Medicine, Michigan State University, East Lansing, MI, 48824, USA
| | - J Ping Liu
- Department of Physics, The University of Texas at Arlington, Arlington, TX, 76019, USA
| | - Christopher H Contag
- Institute for Quantitative Health Science and Engineering (IQ), Michigan State University, East Lansing, MI, 48824, USA
- Department of Biomedical Engineering, College of Engineering, Michigan State University, East Lansing, MI, 48824, USA
- Department of Microbiology and Molecular Genetics, Michigan State University, East Lansing, MI, 48824, USA
| | - Ping Wang
- Precision Health Program, Michigan State University, East Lansing, MI, 48824, USA
- Department of Radiology, College of Human Medicine, Michigan State University, East Lansing, MI, 48824, USA
| |
Collapse
|
8
|
Mohn F, Szwargulski P, Kaul MG, Graeser M, Mummert T, Krishnan KM, Knopp T, Adam G, Salamon J, Riedel C. Real-time multi-contrast magnetic particle imaging for the detection of gastrointestinal bleeding. Sci Rep 2023; 13:22976. [PMID: 38151569 PMCID: PMC10752888 DOI: 10.1038/s41598-023-50041-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2023] [Accepted: 12/14/2023] [Indexed: 12/29/2023] Open
Abstract
Gastrointestinal bleeding, as a potentially life-threatening condition, is typically diagnosed by radiation-based imaging modalities like computed tomography or more invasively catheter-based angiography. Endoscopy enables examination of the upper gastrointestinal tract and the colon but not of the entire small bowel. Magnetic Particle Imaging (MPI) enables non-invasive, volumetric imaging without ionizing radiation. The aim of this study was to evaluate the feasibility of detecting gastrointestinal bleeding by single- and multi-contrast MPI using human-sized organs. A 3D-printed small bowel phantom and porcine small bowel specimens were prepared with a defect within the bowel wall as the source of a bleeding. For multi-contrast MPI, the bowel lumen was filled with an intestinal tracer representing an orally administered tracer. MPI was performed to evaluate the fluid exchange between the vascular compartment of the bowel wall and the lumen while a blood pool tracer was applied. Leakage of the blood pool tracer was observed to the bowel lumen. Multi-contrast MPI enabled co-registration of both tracers at the same location within the bowel lumen indicating gastrointestinal bleeding. Single- and multi-contrast MPI are feasible to visualize gastrointestinal bleeding. Therefore, MPI might emerge as a useful tool for radiation-free detection of bleeding within the entire gastrointestinal tract.
Collapse
Affiliation(s)
- Fabian Mohn
- Section for Biomedical Imaging, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
- Institute for Biomedical Imaging, Hamburg University of Technology, Hamburg, Germany
| | - Patryk Szwargulski
- Section for Biomedical Imaging, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
- Institute for Biomedical Imaging, Hamburg University of Technology, Hamburg, Germany
| | - Michael G Kaul
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Martinistrasse 52, 20246, Hamburg, Germany
| | - Matthias Graeser
- Section for Biomedical Imaging, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
- Institute for Biomedical Imaging, Hamburg University of Technology, Hamburg, Germany
- Fraunhofer Research Institution for Individualized and Cell-based Medical Engineering, IMTE, Lübeck, Germany
- Institute of Medical Engineering, University of Lübeck, Lübeck, Germany
| | - Tobias Mummert
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Martinistrasse 52, 20246, Hamburg, Germany
| | - Kannan M Krishnan
- Department of Materials Science and Engineering, University of Washington, Seattle, USA
| | - Tobias Knopp
- Section for Biomedical Imaging, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
- Institute for Biomedical Imaging, Hamburg University of Technology, Hamburg, Germany
| | - Gerhard Adam
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Martinistrasse 52, 20246, Hamburg, Germany
| | - Johannes Salamon
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Martinistrasse 52, 20246, Hamburg, Germany
| | - Christoph Riedel
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Martinistrasse 52, 20246, Hamburg, Germany.
| |
Collapse
|
9
|
Mohn F, Exner M, Szwargulski P, Möddel M, Knopp T, Graeser M. Saline bolus for negative contrast perfusion imaging in magnetic particle imaging. Phys Med Biol 2023; 68:175026. [PMID: 37609892 DOI: 10.1088/1361-6560/ace309] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2023] [Accepted: 06/29/2023] [Indexed: 08/24/2023]
Abstract
Objective.Magnetic particle imaging (MPI) is capable of high temporal resolution measurements of the spatial distribution of magnetic nanoparticles and therefore well suited for perfusion imaging, which is an important tool in medical diagnosis. Perfusion imaging in MPI usually requires a fresh bolus of tracer material to capture the key signal dynamics. Here, we propose a method to decouple the imaging sequence from the injection of additional tracer material, without further increasing the administered iron dose in the body with each image.Approach.A bolus of physiological saline solution without any particles (negative contrast) diminishes the steady-state concentration of a long-circulating tracer during passage. This depression in the measured concentration contributes to the required contrast dynamics. The presence of a long-circulating tracer is therefore a prerequisite to obtain the negative contrast. As a quantitative tracer based imaging method, the signal is linear in the tracer concentration for any location that contains nanoparticles and zero in the surrounding tissue which does not provide any intrinsic signal. After tracer injection, the concentration over time (positive contrast) can be utilized to calculate dynamic diagnostic parameters like perfusion parameters in vessels and organs. Every acquired perfusion image thus requires a new bolus of tracer with a sufficiently large iron dose to be visible above the background.Main results.Perfusion parameters are calculated based on the time response of the proposed negative bolus and compared to a positive bolus. Results from phantom experiments show that normalized signals from positive and negative boli are concurrent and deviations of calculated perfusion maps are low.Significance.Our method opens up the possibility to increase the total monitoring time of a future patient by utilizing a positive-negative contrast sequence, while minimizing the iron dose per acquired image.
Collapse
Affiliation(s)
- Fabian Mohn
- Institute for Biomedical Imaging, Hamburg University of Technology, Hamburg, Germany
- Section for Biomedical Imaging, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Miriam Exner
- Institute for Biomedical Imaging, Hamburg University of Technology, Hamburg, Germany
| | - Patryk Szwargulski
- Institute for Biomedical Imaging, Hamburg University of Technology, Hamburg, Germany
| | - Martin Möddel
- Institute for Biomedical Imaging, Hamburg University of Technology, Hamburg, Germany
- Section for Biomedical Imaging, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Tobias Knopp
- Institute for Biomedical Imaging, Hamburg University of Technology, Hamburg, Germany
- Section for Biomedical Imaging, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
- Fraunhofer Research Institution for Individualized and Cell-based Medicine, IMTE, Lübeck, Germany
| | - Matthias Graeser
- Institute for Biomedical Imaging, Hamburg University of Technology, Hamburg, Germany
- Section for Biomedical Imaging, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
- Fraunhofer Research Institution for Individualized and Cell-based Medicine, IMTE, Lübeck, Germany
- Institute for Medical Engineering, University of Lübeck, Lübeck, Germany
| |
Collapse
|
10
|
Shang Y, Liu J, Liu Y, Zhang B, Wu X, Zhang L, Tong W, Hui H, Tian J. Anisotropic edge-preserving network for resolution enhancement in unidirectional Cartesian magnetic particle imaging. Phys Med Biol 2023; 68. [PMID: 36689774 DOI: 10.1088/1361-6560/acb584] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2022] [Accepted: 01/23/2023] [Indexed: 01/24/2023]
Abstract
Objective. Magnetic particle imaging (MPI) is a novel imaging modality. It is crucial to acquire accurate localization of the superparamagnetic iron oxide nanoparticles distributions in MPI. However, the spatial resolution of unidirectional Cartesian trajectory MPI exhibits anisotropy, which blurs the boundaries of MPI images and makes precise localization difficult. In this paper, we propose an anisotropic edge-preserving network (AEP-net) to alleviate the anisotropic resolution of MPI.Methods. AEP-net resolve the resolution anisotropy by constructing an asymmertic convolution. To recover the edge information, we design the uncertainty region module. In addition, we evaluated the performance of the proposed AEP-net model by using simulations and experimental data.Results. The results show that the AEP-net model alleviates the anisotropy of the unidirectional Cartesian trajectory and preserves edge details in the MPI image. By comparing the visualization results and the metrics, we demonstrate that our method is superior to other methods.Significance. The proposed method produces accurate visualization in unidirectional Cartesian devices and promotes accurate quantization, which promote the biomedical applications using MPI.
Collapse
Affiliation(s)
- Yaxin Shang
- School of Computer and Information Technology, Beijing Jiaotong University, Beijing, 100044, People's Republic of China
| | - Jie Liu
- School of Computer and Information Technology, Beijing Jiaotong University, Beijing, 100044, People's Republic of China
| | - Yanjun Liu
- School of Biological Science and Medical Engineering, Beihang University, Beijing, 100191, People's Republic of China
| | - Bo Zhang
- School of Biological Science and Medical Engineering, Beihang University, Beijing, 100191, People's Republic of China
| | - Xiangjun Wu
- School of Biological Science and Medical Engineering, Beihang University, Beijing, 100191, People's Republic of China
| | - Liwen Zhang
- CAS Key Laboratory of Molecular Imaging, Beijing Key Laboratory of Molecular Imaging, Institute of Automation, Beijing, 100190, People's Republic of China.,The University of Chinese Academy of Sciences, Beijing, 100080, People's Republic of China
| | - Wei Tong
- Senior Department of Cardiology, the Sixth Medical Center of PLA General Hospital, Beijing, 100036, People's Republic of China
| | - Hui Hui
- CAS Key Laboratory of Molecular Imaging, Beijing Key Laboratory of Molecular Imaging, Institute of Automation, Beijing, 100190, People's Republic of China.,The University of Chinese Academy of Sciences, Beijing, 100080, People's Republic of China
| | - Jie Tian
- CAS Key Laboratory of Molecular Imaging, Beijing Key Laboratory of Molecular Imaging, Institute of Automation, Beijing, 100190, People's Republic of China.,Beijing Advanced Innovation Center for Big Data-Based Precision Medicine, School of Engineering Medicine, Beihang University, Beijing, 100191, People's Republic of China
| |
Collapse
|
11
|
Schutter R, van Varsseveld OC, Lantinga VA, Pool MBF, Hamelink TH, Potze JH, Leuvenink HGD, Laustsen C, Borra RJH, Moers C. Magnetic resonance imaging during warm ex vivo kidney perfusion. Artif Organs 2023; 47:105-116. [PMID: 35996889 PMCID: PMC10086841 DOI: 10.1111/aor.14391] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2022] [Revised: 06/30/2022] [Accepted: 08/02/2022] [Indexed: 01/04/2023]
Abstract
BACKGROUND The shortage of donor organs for transplantation remains a worldwide problem. The utilization of suboptimal deceased donors enlarges the pool of potential organs, yet consequently, clinicians face the difficult decision of whether these sub-optimal organs are of sufficient quality for transplantation. Novel technologies could play a pivotal role in making pre-transplant organ assessment more objective and reliable. METHODS Ex vivo normothermic machine perfusion (NMP) at temperatures around 35-37°C allows organ quality assessment in a near-physiological environment. Advanced magnetic resonance imaging (MRI) techniques convey unique information about an organ's structural and functional integrity. The concept of applying magnetic resonance imaging during renal normothermic machine perfusion is novel in both renal and radiological research and we have developed the first MRI-compatible NMP setup for human-sized kidneys. RESULTS We were able to obtain a detailed and real-time view of ongoing processes inside renal grafts during ex vivo perfusion. This new technique can visualize structural abnormalities, quantify regional flow distribution, renal metabolism, and local oxygen availability, and track the distribution of ex vivo administered cellular therapy. CONCLUSION This platform allows for advanced pre-transplant organ assessment, provides a new realistic tool for studies into renal physiology and metabolism, and may facilitate therapeutic tracing of pharmacological and cellular interventions to an isolated kidney.
Collapse
Affiliation(s)
- Rianne Schutter
- Department of Surgery - Organ Donation and Transplantation, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
| | - Otis C van Varsseveld
- Department of Surgery - Organ Donation and Transplantation, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
| | - Veerle A Lantinga
- Department of Surgery - Organ Donation and Transplantation, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
| | - Merel B F Pool
- Department of Surgery - Organ Donation and Transplantation, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
| | - Tim H Hamelink
- Department of Surgery - Organ Donation and Transplantation, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
| | - Jan Hendrik Potze
- Department of Radiology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
| | - Henri G D Leuvenink
- Department of Surgery - Organ Donation and Transplantation, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
| | - Christoffer Laustsen
- Department of Clinical Medicine, The MR Research Center, Aarhus University, Aarhus, Denmark
| | - Ronald J H Borra
- Department of Radiology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
| | - Cyril Moers
- Department of Surgery - Organ Donation and Transplantation, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
| |
Collapse
|
12
|
Arslan MT, Ozaslan AA, Kurt S, Muslu Y, Saritas EU. Rapid TAURUS for Relaxation-Based Color Magnetic Particle Imaging. IEEE TRANSACTIONS ON MEDICAL IMAGING 2022; 41:3774-3786. [PMID: 35921341 DOI: 10.1109/tmi.2022.3195694] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Magnetic particle imaging (MPI) is a rapidly developing medical imaging modality that exploits the non-linear response of magnetic nanoparticles (MNPs). Color MPI widens the functionality of MPI, empowering it with the capability to distinguish different MNPs and/or MNP environments. The system function approach for color MPI relies on extensive calibrations that capture the differences in the harmonic responses of the MNPs. An alternative calibration-free x-space-based method called TAURUS estimates a map of the relaxation time constant, τ , by recovering the underlying mirror symmetry in the MPI signal. However, TAURUS requires a back and forth scanning of a given region, restricting its usage to slow trajectories with constant or piecewise constant focus fields (FFs). In this work, we propose a novel technique to increase the performance of TAURUS and enable τ map estimation for rapid and multi-dimensional trajectories. The proposed technique is based on correcting the distortions on mirror symmetry induced by time-varying FFs. We demonstrate via simulations and experiments in our in-house MPI scanner that the proposed method successfully estimates high-fidelity τ maps for rapid trajectories that provide orders of magnitude reduction in scanning time (over 300 fold for simulations and over 8 fold for experiments) while preserving the calibration-free property of TAURUS.
Collapse
|
13
|
Harvell-Smith S, Tung LD, Thanh NTK. Magnetic particle imaging: tracer development and the biomedical applications of a radiation-free, sensitive, and quantitative imaging modality. NANOSCALE 2022; 14:3658-3697. [PMID: 35080544 DOI: 10.1039/d1nr05670k] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
Magnetic particle imaging (MPI) is an emerging tracer-based modality that enables real-time three-dimensional imaging of the non-linear magnetisation produced by superparamagnetic iron oxide nanoparticles (SPIONs), in the presence of an external oscillating magnetic field. As a technique, it produces highly sensitive radiation-free tomographic images with absolute quantitation. Coupled with a high contrast, as well as zero signal attenuation at-depth, there are essentially no limitations to where that can be imaged within the body. These characteristics enable various biomedical applications of clinical interest. In the opening sections of this review, the principles of image generation are introduced, along with a detailed comparison of the fundamental properties of this technique with other common imaging modalities. The main feature is a presentation on the up-to-date literature for the development of SPIONs tailored for improved imaging performance, and developments in the current and promising biomedical applications of this emerging technique, with a specific focus on theranostics, cell tracking and perfusion imaging. Finally, we will discuss recent progress in the clinical translation of MPI. As signal detection in MPI is almost entirely dependent on the properties of the SPION employed, this work emphasises the importance of tailoring the synthetic process to produce SPIONs demonstrating specific properties and how this impacts imaging in particular applications and MPI's overall performance.
Collapse
Affiliation(s)
- Stanley Harvell-Smith
- Biophysics Group, Department of Physics and Astronomy, University College London, Gower Street, London WC1E 6BT, UK.
- UCL Healthcare Biomagnetic and Nanomaterials Laboratories, University College London, 21 Albemarle Street, London W1S 4BS, UK
| | - Le Duc Tung
- Biophysics Group, Department of Physics and Astronomy, University College London, Gower Street, London WC1E 6BT, UK.
- UCL Healthcare Biomagnetic and Nanomaterials Laboratories, University College London, 21 Albemarle Street, London W1S 4BS, UK
| | - Nguyen Thi Kim Thanh
- Biophysics Group, Department of Physics and Astronomy, University College London, Gower Street, London WC1E 6BT, UK.
- UCL Healthcare Biomagnetic and Nanomaterials Laboratories, University College London, 21 Albemarle Street, London W1S 4BS, UK
| |
Collapse
|
14
|
Ludewig P, Graeser M, Forkert ND, Thieben F, Rández-Garbayo J, Rieckhoff J, Lessmann K, Förger F, Szwargulski P, Magnus T, Knopp T. Magnetic particle imaging for assessment of cerebral perfusion and ischemia. WILEY INTERDISCIPLINARY REVIEWS-NANOMEDICINE AND NANOBIOTECHNOLOGY 2021; 14:e1757. [PMID: 34617413 DOI: 10.1002/wnan.1757] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/08/2021] [Revised: 08/30/2021] [Accepted: 09/03/2021] [Indexed: 02/04/2023]
Abstract
Stroke is one of the leading worldwide causes of death and sustained disability. Rapid and accurate assessment of cerebral perfusion is essential to diagnose and successfully treat stroke patients. Magnetic particle imaging (MPI) is a new technology with the potential to overcome some limitations of established imaging modalities. It is an innovative and radiation-free imaging technique with high sensitivity, specificity, and superior temporal resolution. MPI enables imaging and diagnosis of stroke and other neurological pathologies such as hemorrhage, tumors, and inflammatory processes. MPI scanners also offer the potential for targeted therapies of these diseases. Due to lower field requirements, MPI scanners can be designed as resistive magnets and employed as mobile devices for bedside imaging. With these advantages, MPI could accelerate and improve the diagnosis and treatment of neurological disorders. This review provides a basic introduction to MPI, discusses its current use for stroke imaging, and addresses future applications, including the potential for clinical implementation. This article is categorized under: Diagnostic Tools > In Vivo Nanodiagnostics and Imaging Therapeutic Approaches and Drug Discovery > Nanomedicine for Neurological Disease.
Collapse
Affiliation(s)
- Peter Ludewig
- Department of Neurology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Matthias Graeser
- Section for Biomedical Imaging at the University Medical Center Hamburg-Eppendorf, Hamburg, Germany.,Institute for Biomedical Imaging, Hamburg University of Technology, Hamburg, Germany.,Fraunhofer Research Institute for Individualized and Cell-based Medicine, Lübeck, Germany.,Institute for Medical Engineering, University of Lübeck, Lübeck, Germany
| | - Nils D Forkert
- Department of Radiology and Hotchkiss Brain Institute, University of Calgary, Calgary, Canada
| | - Florian Thieben
- Section for Biomedical Imaging at the University Medical Center Hamburg-Eppendorf, Hamburg, Germany.,Institute for Biomedical Imaging, Hamburg University of Technology, Hamburg, Germany
| | - Javier Rández-Garbayo
- Department of Neurology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Johanna Rieckhoff
- Department of Neurology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Katrin Lessmann
- Department of Neurology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Fynn Förger
- Section for Biomedical Imaging at the University Medical Center Hamburg-Eppendorf, Hamburg, Germany.,Institute for Biomedical Imaging, Hamburg University of Technology, Hamburg, Germany
| | - Patryk Szwargulski
- Section for Biomedical Imaging at the University Medical Center Hamburg-Eppendorf, Hamburg, Germany.,Institute for Biomedical Imaging, Hamburg University of Technology, Hamburg, Germany
| | - Tim Magnus
- Department of Neurology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Tobias Knopp
- Section for Biomedical Imaging at the University Medical Center Hamburg-Eppendorf, Hamburg, Germany.,Institute for Biomedical Imaging, Hamburg University of Technology, Hamburg, Germany
| |
Collapse
|
15
|
Magnetic particle imaging for artifact-free imaging of intracranial flow diverter stents: A phantom study. Phys Med 2021; 88:65-70. [PMID: 34192659 DOI: 10.1016/j.ejmp.2021.06.018] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/04/2021] [Revised: 05/10/2021] [Accepted: 06/21/2021] [Indexed: 11/20/2022] Open
Abstract
PURPOSE Magnetic Particle Imaging (MPI) is a new, background- and radiation-free tomographic imaging method that enables near real-time imaging of superparamagnetic iron-oxide nanoparticles (SPIONs) with high temporal and spatial resolution. This phantom study aims to investigate the potential of MPI for visualization of the stent lumen in intracranial flow diverters (FD). METHODS Nitinol FD of different dimensions (outer diameter: 3.5 mm, 4.0 mm, 5.5 mm; total length: 22-40 mm) were scanned in vascular phantoms in a custom-built MPI scanner (in-plane resolution: ~ 2 mm, field of view: 65 mm length, 29 mm diameter). Phantoms were filled with diluted (1:50) SPION tracer agent Ferucarbotran (10 µmol (Fe)/ml; NaCL). Each phantom was measured in 32 different projections (overall acquisition time per image: 3200 ms, 5averages). After image reconstruction from raw data, two radiologists assessed image quality using a 5-point Likert scale. The signal intensity profile was measured using a semi-automatic evaluation tool. RESULTS MPI visualized the lumen of all FD without relevant differences between the stented vessel phantom and the reference phantom. At 3.5 mm image quality was slightly inferior to the larger diameters. The FD themselves neither generated an MPI signal nor did they lead to relevant imaging artifacts. Ratings of both radiologists showed no significant difference, interrater reliability was good (ICC 0.84). A quantitative evaluation of the signal intensity profile did not reveal any significant differences (p > 0.05) either. CONCLUSION MPI visualizes the lumen of nitinol FD stents in vessel phantoms without relevant stent-induced artifacts.
Collapse
|
16
|
Pulmonary blood volume estimation in mice by magnetic particle imaging and magnetic resonance imaging. Sci Rep 2021; 11:4848. [PMID: 33649416 PMCID: PMC7921594 DOI: 10.1038/s41598-021-84276-9] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2020] [Accepted: 02/10/2021] [Indexed: 11/27/2022] Open
Abstract
This methodical work describes the measurement and calculation of pulmonary blood volume in mice based on two imaging techniques namely by using magnetic particle imaging (MPI) and cardiac magnetic resonance imaging (MRI). Besides its feasibility aspects that may influence quantitative analysis are studied. Eight FVB mice underwent cardiac MRI to determine stroke volumes and anatomic MRI as morphological reference for functional MPI data. Arrival time analyses of boli of 1 µl of 1 M superparamagnetic tracer were performed by MPI. Pulmonary transit time of the bolus was determined by measurements in the right and left ventricles. Pulmonary blood volume was calculated out of stroke volume, pulmonary transit time and RR-interval length including a maximal error analysis. Cardiac stroke volume was 31.7 µl ± 2.3 µl with an ejection fraction of 71% ± 6%. A sharp contrast bolus profile was observed by MPI allowing subdividing the first pass into three distinct phases: tracer arrival in the right ventricle, pulmonary vasculature, and left ventricle. The bolus full width at half maximum was 578 ms ± 144 ms in the right ventricle and 1042 ms ± 150 ms in the left ventricle. Analysis of pulmonary transit time revealed 745 ms ± 81 ms. Mean RR-interval length was 133 ms ± 12 ms. Pulmonary blood volume resulted in 177 µl ± 27 µl with a mean maximal error limit of 27 µl. Non-invasive assessment of the pulmonary blood volume in mice was feasible. This technique can be of specific value for evaluation of pulmonary hemodynamics in mouse models of cardiac dysfunction or pulmonary disease. Pulmonary blood volume can complement cardiac functional parameters as a further hemodynamic parameter.
Collapse
|
17
|
Dietrich P, Vogel P, Kampf T, Rückert MA, Behr VC, Bley TA, Herz S. Near real-time magnetic particle imaging for visual assessment of vascular stenosis in a phantom model. Phys Med 2021; 81:210-214. [PMID: 33477058 DOI: 10.1016/j.ejmp.2020.12.020] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/14/2020] [Revised: 11/30/2020] [Accepted: 12/25/2020] [Indexed: 11/26/2022] Open
Abstract
PURPOSE This study aimed to investigate the potential of magnetic particle imaging (MPI) to quantify artificial stenoses in vessel phantoms in near real-time. METHODS Custom-made stenosis phantoms with different degrees of stenosis (0%, 25%, 50%, 75%, and 100%; length 40 mm, inner diameter 8 mm, Polyoxymethylene) were filled with diluted Ferucarbotran (superparamagnetic iron-oxide nanoparticle (SPION) tracer agent, 500 mmol (Fe)/l). A traveling wave MPI scanner (spatial resolution ~ 2 mm, gradient strength ~ 1.5 T/m, field of view: 65 mm length and 29 mm diameter, frequencies f1 = 1050 Hz and f2 = 12150 Hz) was used to acquire images of the phantoms (200 ms total acquisition time per image, 10 averages). Standardized grey scaling was used for comparability. All measured stenoses (n = 80) were graded manually using a dedicated software tool. RESULTS MPI allowed for accurate visualization of stenoses at a frame rate of 5frames per second. Less severe stenoses were detected more precisely than higher-grade stenoses and came with smaller standard deviations. In particular, the 0%, 25%, 50%, 75%, and 100% stenosis phantom were measured as 3.7 ± 2.7% (mean ± standarddeviation), 18.6 ± 1.8%, 52.8 ± 3.7%, 77.8 ± 14.8% and 100 ± 0%. Geometrical distortions occurred around the center of the high-grade stenosis and led to higher standard deviations compared to lower grade stenoses. In the frame of this study the MPI signal depended linearly on the SPION concentration down to 0.05 mmol (Fe)/l. CONCLUSION Near real-time MPI accurately visualized and quantified different stenosis grades in vascular phantoms.
Collapse
Affiliation(s)
- Philipp Dietrich
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Würzburg, Germany.
| | - Patrick Vogel
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Würzburg, Germany; Department of Experimental Physics V, University of Würzburg, Würzburg, Germany.
| | - Thomas Kampf
- Department of Experimental Physics V, University of Würzburg, Würzburg, Germany; Department of Diagnostic and Interventional Neuroradiology, University Hospital Würzburg, Würzburg, Germany.
| | - Martin A Rückert
- Department of Experimental Physics V, University of Würzburg, Würzburg, Germany.
| | - Volker C Behr
- Department of Experimental Physics V, University of Würzburg, Würzburg, Germany.
| | - Thorsten A Bley
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Würzburg, Germany.
| | - Stefan Herz
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Würzburg, Germany.
| |
Collapse
|
18
|
Lu Y, Rivera-Rodriguez A, Tay ZW, Hensley D, Fung KLB, Colson C, Saayujya C, Huynh Q, Kabuli L, Fellows B, Chandrasekharan P, Rinaldi C, Conolly S. Combining magnetic particle imaging and magnetic fluid hyperthermia for localized and image-guided treatment. Int J Hyperthermia 2021; 37:141-154. [PMID: 33426994 DOI: 10.1080/02656736.2020.1853252] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022] Open
Abstract
Magnetic fluid hyperthermia (MFH) has been widely investigated as a treatment tool for cancer and other diseases. However, focusing traditional MFH to a tumor deep in the body is not feasible because the in vivo wavelength of 300 kHz very low frequency (VLF) excitation fields is longer than 100 m. Recently we demonstrated that millimeter-precision localized heating can be achieved by combining magnetic particle imaging (MPI) with MFH. In principle, real-time MPI imaging can also guide the location and dosing of MFH treatments. Hence, the combination of MPI imaging plus real time localized MPI-MFH could soon permit closed-loop high-resolution hyperthermia treatment. In this review, we will discuss the fundamentals of localized MFH (e.g. physics and biosafety limitations), hardware implementation, MPI real-time guidance, and new research directions on MPI-MFH. We will also discuss how the scale up to human-sized MPI-MFH scanners could proceed.
Collapse
Affiliation(s)
- Yao Lu
- Department of Bioengineering, University of California Berkeley, Berkeley, CA, USA
| | - Angelie Rivera-Rodriguez
- J. Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, Gainesville, FL, USA
| | - Zhi Wei Tay
- Department of Bioengineering, University of California Berkeley, Berkeley, CA, USA
| | | | - K L Barry Fung
- Department of Bioengineering, University of California Berkeley, Berkeley, CA, USA
| | - Caylin Colson
- Department of Bioengineering, University of California Berkeley, Berkeley, CA, USA
| | - Chinmoy Saayujya
- Department of Electrical Engineering and Computer Sciences, University of California, Berkeley, CA, USA
| | - Quincy Huynh
- Department of Electrical Engineering and Computer Sciences, University of California, Berkeley, CA, USA
| | - Leyla Kabuli
- Department of Electrical Engineering and Computer Sciences, University of California, Berkeley, CA, USA
| | - Benjamin Fellows
- Department of Bioengineering, University of California Berkeley, Berkeley, CA, USA
| | | | - Carlos Rinaldi
- J. Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, Gainesville, FL, USA.,Department of Chemical Engineering, University of Florida, Gainesville, FL, USA
| | - Steven Conolly
- Department of Bioengineering, University of California Berkeley, Berkeley, CA, USA.,Department of Electrical Engineering and Computer Sciences, University of California, Berkeley, CA, USA
| |
Collapse
|
19
|
Top CB, Gungor A. Tomographic Field Free Line Magnetic Particle Imaging With an Open-Sided Scanner Configuration. IEEE TRANSACTIONS ON MEDICAL IMAGING 2020; 39:4164-4173. [PMID: 32746156 DOI: 10.1109/tmi.2020.3014197] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Superparamagnetic iron oxide nanoparticles (SPIONs) have a high potential for use in clinical diagnostic and therapeutic applications. In vivo distribution of SPIONs can be imaged with the Magnetic Particle Imaging (MPI) method, which uses an inhomogeneous magnetic field with a field free region (FFR). The spatial distribution of the SPIONs are obtained by scanning the FFR inside the field of view (FOV) and sensing SPION related magnetic field disturbance. MPI magnets can be configured to generate a field free point (FFP), or a field free line (FFL) to scan the FOV. FFL scanners provide more sensitivity, and are also more suitable for scanning large regions compared to FFP scanners. Interventional procedures will benefit greatly from FFL based open magnet configurations. Here, we present the first open-sided MPI system that can electronically scan the FOV with an FFL to generate tomographic MPI images. Magnetic field measurements show that FFL can be rotated electronically in the horizontal plane and translated in three dimensions to generate 3D MPI images. Using the developed scanner, we obtained 2D images of dot and cylinder phantoms with varying iron concentrations between 11 [Formula: see text]/ml and 770 [Formula: see text]/ml. We used a measurement based system matrix image reconstruction method that minimizes l1 -norm and total variation in the images. Furthermore, we present 2D imaging results of two 4 mm-diameter vessel phantoms with 0% and 75% stenosis. The experiments show high quality imaging results with a resolution down to 2.5 mm for a relatively low gradient field of 0.6 T/m.
Collapse
|
20
|
Abstract
The field of nanomedicine has recently emerged as a product of the expansion of a range of nanotechnologies into biomedical science, pharmacology and clinical practice. Due to the unique properties of nanoparticles and the related nanostructures, their applications to medical diagnostics, imaging, controlled drug and gene delivery, monitoring of therapeutic outcomes, and aiding in medical interventions, provide a new perspective for challenging problems in such demanding issues as those involved in the treatment of cancer or debilitating neurological diseases. In this review, we evaluate the role and contributions that the applications of magnetic nanoparticles (MNPs) have made to various aspects of nanomedicine, including the newest magnetic particle imaging (MPI) technology allowing for outstanding spatial and temporal resolution that enables targeted contrast enhancement and real-time assistance during medical interventions. We also evaluate the applications of MNPs to the development of targeted drug delivery systems with magnetic field guidance/focusing and controlled drug release that mitigate chemotherapeutic drugs’ side effects and damage to healthy cells. These systems enable tackling of multiple drug resistance which develops in cancer cells during chemotherapeutic treatment. Furthermore, the progress in development of ROS- and heat-generating magnetic nanocarriers and magneto-mechanical cancer cell destruction, induced by an external magnetic field, is also discussed. The crucial roles of MNPs in the development of biosensors and microfluidic paper array devices (µPADs) for the detection of cancer biomarkers and circulating tumor cells (CTCs) are also assessed. Future challenges concerning the role and contributions of MNPs to the progress in nanomedicine have been outlined.
Collapse
|