1
|
He J, Zhong R, Xue L, Wang Y, Chen Y, Xiong Z, Yang Z, Chen S, Liang W, He J. Exhaled Volatile Organic Compounds Detection in Pneumonia Screening: A Comprehensive Meta-analysis. Lung 2024; 202:501-511. [PMID: 39180684 PMCID: PMC11427597 DOI: 10.1007/s00408-024-00737-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2024] [Accepted: 08/01/2024] [Indexed: 08/26/2024]
Abstract
BACKGROUND Pneumonia is a common lower respiratory tract infection, and early diagnosis is crucial for timely treatment and improved prognosis. Traditional diagnostic methods for pneumonia, such as chest imaging and microbiological examinations, have certain limitations. Exhaled volatile organic compounds (VOCs) detection, as an emerging non-invasive diagnostic technique, has shown potential application value in pneumonia screening. METHOD A systematic search was conducted on PubMed, Embase, Cochrane Library, and Web of Science, with the retrieval time up to March 2024. The inclusion criteria were diagnostic studies evaluating exhaled VOCs detection for the diagnosis of pneumonia, regardless of the trial design type. A meta-analysis was performed using a bivariate model for sensitivity and specificity. RESULTS A total of 14 diagnostic studies were included in this meta-analysis. The pooled results demonstrated that exhaled VOCs detection had a combined sensitivity of 0.94 (95% CI: 0.92-0.95) and a combined specificity of 0.83 (95% CI: 0.81-0.84) in pneumonia screening, with an area under the summary receiver operating characteristic (SROC) curve (AUC) of 0.96. The pooled diagnostic odds ratio (DOR) was 104.37 (95% CI: 27.93-390.03), and the pooled positive and negative likelihood ratios (LR) were 8.98 (95% CI: 3.88-20.80) and 0.11 (95% CI: 0.05-0.22), indicating a high diagnostic performance. CONCLUSION This study highlights the potential of exhaled VOCs detection as an effective, non-invasive screening method for pneumonia, which could facilitate future diagnosis in pneumonia. Further high-quality, large-scale studies are required to confirm the clinical utility of exhaled VOCs detection in pneumonia screening. STUDY REGISTRATION PROSPERO, Review no. CRD42024520498.
Collapse
Affiliation(s)
- Juan He
- Nanshan School, Guangzhou Medical University, Jingxiu Road, Panyu District, Guangzhou, 511436, China.
| | - Ran Zhong
- Department of Thoracic Surgery and Oncology, National Center for Respiratory Health, Guangzhou Institute of Respiratory Health, the First Affiliated Hospital of Guangzhou Medical University, Guangzhou, 510120, China
- Nanshan School, Guangzhou Medical University, Jingxiu Road, Panyu District, Guangzhou, 511436, China
| | - Linlu Xue
- Guangzhou Yuexiu Huanghuagang Street Community Health Service Center, Guangzhou, 510075, China
| | - Yixuan Wang
- Nanshan School, Guangzhou Medical University, Jingxiu Road, Panyu District, Guangzhou, 511436, China
| | - Yang Chen
- Nanshan School, Guangzhou Medical University, Jingxiu Road, Panyu District, Guangzhou, 511436, China
| | - Zihui Xiong
- Nanshan School, Guangzhou Medical University, Jingxiu Road, Panyu District, Guangzhou, 511436, China
| | - Ziya Yang
- The First Clinical School, Guangzhou Medical University, Jingxiu Road, Panyu District, Guangzhou, 511436, China
| | - Sitong Chen
- ChromX Health Company Limited, Guangzhou, 510120, China
| | - Wenhua Liang
- Department of Thoracic Surgery and Oncology, National Center for Respiratory Health, Guangzhou Institute of Respiratory Health, the First Affiliated Hospital of Guangzhou Medical University, Guangzhou, 510120, China.
| | - Jianxing He
- Department of Thoracic Surgery and Oncology, National Center for Respiratory Health, Guangzhou Institute of Respiratory Health, the First Affiliated Hospital of Guangzhou Medical University, Guangzhou, 510120, China.
| |
Collapse
|
2
|
Seyfinejad B, Nemutlu E, Taghizadieh A, Khoubnasabjafari M, Ozkan SA, Jouyban A. Biomarkers in exhaled breath condensate as fingerprints of asthma, chronic obstructive pulmonary disease and asthma-chronic obstructive pulmonary disease overlap: a critical review. Biomark Med 2023; 17:811-837. [PMID: 38179966 DOI: 10.2217/bmm-2023-0420] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2024] Open
Abstract
Asthma, chronic obstructive pulmonary disease (COPD) and asthma-COPD overlap are the third leading cause of mortality around the world. They share some common features, which can lead to misdiagnosis. To properly manage these conditions, reliable markers for early and accurate diagnosis are needed. Over the past 20 years, many molecules have been investigated in the exhaled breath condensate to better understand inflammation pathways and mechanisms related to these disorders. Recently, more advanced techniques, such as sensitive metabolomic and proteomic profiling, have been used to obtain a more comprehensive understanding. This article reviews the use of targeted and untargeted metabolomic methodology to study asthma, COPD and asthma-COPD overlap.
Collapse
Affiliation(s)
- Behrouz Seyfinejad
- Pharmaceutical Analysis Research Center & Faculty of Pharmacy, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Emirhan Nemutlu
- Department of Analytical Chemistry, Faculty of Pharmacy, Hacettepe University, Ankara, 06100, Turkiye
| | - Ali Taghizadieh
- Tuberculosis & Lung Diseases Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
- Department of Internal Medicine, Faculty of Medicine, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Maryam Khoubnasabjafari
- Tuberculosis & Lung Diseases Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
- Department of Anesthesiology & Intensive Care, Faculty of Medicine, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Sibel A Ozkan
- Ankara University, Faculty of Pharmacy, Department of Analytical Chemistry, Ankara, 06560, Turkiye
| | - Abolghasem Jouyban
- Pharmaceutical Analysis Research Center & Faculty of Pharmacy, Tabriz University of Medical Sciences, Tabriz, Iran
- Faculty of Pharmacy, Near East University, PO Box 99138 Nicosia, North Cyprus, Mersin 10, Turkiye
| |
Collapse
|
3
|
Wei S, Chen YS, Shi Y. Metabolomic profiling of exhaled breath condensate for the diagnosis of pulmonary aspergillosis. Front Cell Infect Microbiol 2022; 12:1008924. [PMID: 36159648 PMCID: PMC9492867 DOI: 10.3389/fcimb.2022.1008924] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2022] [Accepted: 08/22/2022] [Indexed: 11/13/2022] Open
Abstract
ObjectiveThis study aims to ascertain the unique metabolic profile of exhaled breath condensate (EBC) samples in pulmonary aspergillosis (PA) patients, and explore their usefulness for the diagnosis of PA.MethodsA total of 133 patients were included in the study, including 66 PA patients (invasive pulmonary aspergillosis, n=3; chronic pulmonary aspergillosis, n=60; allergic bronchopulmonary aspergillosis, n=3) and controls (n=67). Ultra high-performance liquid chromatography coupled with high-resolution mass spectrometry(UHPLC-HRMS) was used to analyze EBC samples. Metabolic profiling of EBC samples that were collected from 22 CPA patients at various times during treatment (before treatment, <1 month, 1–2 months, 2–3 months, 3–6 months, and ≥6 months after treatment initiation) were performed using UHPLC-HRMS. Potential biomarkers were evaluated using cluster analysis, Venn diagram and receiver operating characteristic analysis (ROC).ResultsA total of 47 metabolites of potential interest were detected in the EBC samples. Further investigation showed that Asperpyrone C, Kotanin, Terphenyllin, Terrelumamide B, and Cyclotryprostatin D could be used as a diagnostic biomarker for PA. The classification between metabolic profiling of EBC samples from PA patients and controls was good with a sensitivity of 100%, specificity 89.6% for patients with PA, respectively. Venn diagram analysis of these biomarker candidates displayed three main types of compounds, which could be used for the further discrimination of aspergilloma and chronic cavitary PA. In addition, antifungal treatment had a limited influence on the value of the EBC results.ConclusionsThis metabolomic approach using UHPLC-HRMS could be used as a noninvasive method for the diagnosis of PA.
Collapse
Affiliation(s)
- Shuo Wei
- Department of Infectious Disease, Shengli Clinical Medical College of Fujian Medical University, Fujian Provincial Hospital, Fuzhou, China
- *Correspondence: Shuo Wei, ; Yi Shi,
| | - Yi-sheng Chen
- Department of Clinical Laboratory, Shengli Clinical Medical College of Fujian Medical University, Fujian Provincial Hospital, Fuzhou, China
| | - Yi Shi
- Department of Respiratory Medicine, Jinling Hospital, Nanjing, China
- *Correspondence: Shuo Wei, ; Yi Shi,
| |
Collapse
|
4
|
Hemmendinger M, Sauvain JJ, Hopf NB, Suárez G, Guseva Canu I. Challenges in Quantifying 8-OHdG and 8-Isoprostane in Exhaled Breath Condensate. Antioxidants (Basel) 2022; 11:antiox11050830. [PMID: 35624694 PMCID: PMC9138069 DOI: 10.3390/antiox11050830] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2022] [Revised: 04/20/2022] [Accepted: 04/21/2022] [Indexed: 11/21/2022] Open
Abstract
Exhaled breath condensate (EBC) has attracted substantial interest in the last few years, enabling the assessment of airway inflammation with a non-invasive method. Concentrations of 8-Hydroxydesoxyguanosine (8-OHdG) and 8-isoprostane in EBC have been suggested as candidate biomarkers for lung diseases associated with inflammation and oxidative stress. EBC is a diluted biological matrix and consequently, requires highly sensitive chemical analytic methods (picomolar range) for biomarker quantification. We developed a new liquid chromatography coupled to tandem mass spectrometry method to quantify 8-OHdG and 8-isoprostane in EBC simultaneously. We applied this novel biomarker method in EBC obtained from 10 healthy subjects, 7 asthmatic subjects, and 9 subjects with chronic obstructive pulmonary disease. Both biomarkers were below the limit of detection (LOD) despite the good sensitivity of the chemical analytical method (LOD = 0.5 pg/mL for 8-OHdG; 1 pg/mL for 8-isoprostane). This lack of detection might result from factors affecting EBC collections. These findings are in line with methodological concerns already raised regarding the reliability of EBC collection for quantification of 8-OHdG and 8-isoprostane. Precaution is therefore needed when comparing literature results without considering methodological issues relative to EBC collection and analysis. Loss of analyte during EBC collection procedures still needs to be resolved before using these oxidative stress biomarkers in EBC.
Collapse
|
5
|
Fois SS, Canu S, Fois AG. The Role of Oxidative Stress in Sarcoidosis. Int J Mol Sci 2021; 22:ijms222111712. [PMID: 34769145 PMCID: PMC8584035 DOI: 10.3390/ijms222111712] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2021] [Revised: 10/24/2021] [Accepted: 10/26/2021] [Indexed: 01/15/2023] Open
Abstract
Sarcoidosis is a rare, systemic inflammatory disease whose diagnosis and management can pose a challenge for clinicians and specialists. Scientific knowledge on the molecular pathways that drive its development is still lacking, with no standardized therapies available and insufficient strategies to predict patient outcome. In recent years, oxidative stress has been highlighted as an important factor in the pathogenesis of sarcoidosis, involving several enzymes and molecules in the mechanism of the disease. This review presents current data on the role of oxidative stress in sarcoidosis and its interaction with inflammation, as well as the application of antioxidative therapy in the disease.
Collapse
Affiliation(s)
- Sara Solveig Fois
- Department of Medical, Surgical and Experimental Sciences, University of Sassari, Viale San Pietro 43, 07100 Sassari, Italy;
- Correspondence:
| | - Sara Canu
- Respiratory Diseases Operative Unit, University Hospital of Sassari, 07100 Sassari, Italy;
| | - Alessandro Giuseppe Fois
- Department of Medical, Surgical and Experimental Sciences, University of Sassari, Viale San Pietro 43, 07100 Sassari, Italy;
| |
Collapse
|
6
|
Oxidative Stress and Inflammatory Mediators in Exhaled Breath Condensate of Patients with Pulmonary Tuberculosis. A Pilot Study with a Biomarker Perspective. Antioxidants (Basel) 2021; 10:antiox10101572. [PMID: 34679707 PMCID: PMC8533495 DOI: 10.3390/antiox10101572] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2021] [Revised: 09/22/2021] [Accepted: 09/23/2021] [Indexed: 12/21/2022] Open
Abstract
Tuberculosis (TB) is one of the highest infectious burdens worldwide. An excess of inflammation and inadequate antioxidant defense mechanisms are believed to lead to chronic inflammation and lung damage in tuberculosis (TB). However, circulating metabolites do not always replicate lung-associated biomarkers that define the pathobiology of the disease. The objective of this study was to determine the utility of exhaled breath condensate (EBC), a non-invasive and straightforward sample, to evaluate alveolar space-derived metabolites of redox state and inflammation. We assessed the levels of exhaled oxidant/antioxidant parameters (8-isoprostane, MDA, GSH), inflammatory markers, such as nucleosomes, cytokines (IL-2, IL-4, IL-6 and IL-8, IL-10, GM-CSF, TNF-α, and IFN-γ) and lipid mediators (PGE2, LTB4, RvD1, and Mar1), in patients with recently diagnosed pulmonary TB and healthy controls’ EBC and serum. The TB patients showed 36% lower GSH levels, and 2-, 1.4-, 1.1-, and 50-fold higher levels of 8-isoprostanes, nucleosomes, IL-6, and LTB4, respectively, in EBC. There was no correlation between EBC and serum, highlighting the importance of measuring local biomarkers. Quantitation of local inflammatory molecules and redox states in EBC would help find biomarkers useful for pharmacological and follow-up studies in pulmonary tuberculosis.
Collapse
|
7
|
Duman B, Borekci S, Akdeniz N, Gazioglu SB, Deniz G, Gemicioglu B. Inhaled corticosteroids' effects on biomarkers in exhaled breath condensate and blood in patients newly diagnosed with asthma who smoke. J Asthma 2021; 59:1613-1620. [PMID: 34376110 DOI: 10.1080/02770903.2021.1962341] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
OBJECTIVE Exposure to cigarette smoke complicates the treatment and management of asthma through a variety of inflammatory effects. This study aimed to investigate the differences between newly diagnosed cases of asthma in smokers and nonsmokers in terms of localized and systemic biomarkers following treatment with inhaled corticosteroids (ICS) or ICS in combination with a long-acting β2 agonist (LABA). METHODS Specimens of exhaled breath condensate (EBC) from newly diagnosed patients with asthma were used to quantify inflammation in the airways, while blood samples were used to assess systemic inflammation. In both samples, the levels of IL-6, LTB4, LTD4, and 8-isoprostane were measured and these were repeated after 3 months of treatment with ICS or ICS + LABA. RESULTS Of the 20 patients, 10 (50%) were nonsmokers with asthma (NSA) and 10 (50%) smokers with asthma (SA). There was no statistically significant difference in the blood or EBC levels of IL-6, LTB4, LTD4, or 8-isoprostane between the groups prior to treatment. Only the decrease in 8-isoprostane level in the EBC samples was found to be significantly greater in the NSA group after treatment (for smokers, the change was 2.91 ± 23.22, while for nonsmokers it was -22.72 ± 33.12, p = 0.022). Post-treatment asthma control was significantly better in the NSA group (p = 0.033). CONCLUSION Monitoring the alterations in 8-isoprostane levels in EBC in patients with asthma who smoke may be helpful in deciding on therapeutic management and switching treatments. Asthma control was better in nonsmokers than in smokers.
Collapse
Affiliation(s)
- Berna Duman
- Bezmiâlem Vakıf University School of Medicine, Istanbul, Turkey
| | - Sermin Borekci
- Department of Pulmonary Diseases, Cerrahpasa Medical Faculty, Istanbul University-Cerrahpasa, Istanbul, Turkey
| | - Nilgun Akdeniz
- Department of Immunology, Institute of Experimental Medicine, Istanbul University, Istanbul, Turkey
| | - Sema Bilgic Gazioglu
- Department of Immunology, Institute of Experimental Medicine, Istanbul University, Istanbul, Turkey
| | - Gunnur Deniz
- Department of Immunology, Institute of Experimental Medicine, Istanbul University, Istanbul, Turkey
| | - Bilun Gemicioglu
- Department of Pulmonary Diseases, Cerrahpasa Medical Faculty, Istanbul University-Cerrahpasa, Istanbul, Turkey
| |
Collapse
|
8
|
Duchene B, Caffry S, Kaminsky DA, Que LG, Poynter ME, Dixon AE. Functional significance of 8-isoprostanes in sinonasal disease and asthma. Respir Med 2021; 185:106506. [PMID: 34166960 PMCID: PMC9531183 DOI: 10.1016/j.rmed.2021.106506] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/23/2021] [Revised: 05/19/2021] [Accepted: 06/05/2021] [Indexed: 12/29/2022]
Abstract
BACKGROUND The purpose of this study was to investigate how 8-isoprostanes, used as a marker of airway oxidative stress, were related to sinus disease and asthma. METHODS We analyzed samples and data from two separate studies, one investigating sinonasal disease in asthma, the other investigating the effect of BMI on airway disease. We measured airway (nasal lavage) 8-isoprostanes and investigated the relationship with measures of sinus and asthma symptoms, asthma control and lung function. RESULTS The study of people with sinonasal disease and poorly controlled asthma included 48 obese, 31 overweight and 23 lean participants. In multivariate analysis, nasal lavage 8-isoprostane levels increased with increasing BMI (p < 0.01), and were higher in Caucasian than African American participants (p = 0.01). Sinus symptoms were inversely related to nasal 8-isoprostanes (p = 0.02) independent of BMI and Race. In the study investigating the effect of BMI on airway disease, we enrolled 13 controls with obesity and 21 people with obesity and asthma: 8-isoprostane levels were higher in obese controls than in obese people with asthma (p < 0.01), and levels were inversely related to sinus symptoms (p = 0.02) and asthma control (p < 0.01). INTERPRETATION 8-isoprostanes in nasal lavage are increased in obesity, and increased in Caucasians compared with African Americans. However, levels are higher in obese controls than obese people with asthma, and appear inversely related to symptoms of airway disease. CLINICAL IMPLICATION Airway 8-isoprostanes likely reflect complex oxidative signaling pathways, which are altered in obesity and those of different race, rather than being a simple marker of airway oxidative injury. CAPSULE SUMMARY Increased airway oxidative signaling (8-isoprostanes), may reflect normal physiology in the setting of obesity, as decreased levels are associated with disease activity in people with chronic sinonasal disease and asthma.
Collapse
Affiliation(s)
- Brittany Duchene
- Larner College of Medicine, University of Vermont, Burlington, VT, USA
| | - Sarah Caffry
- Larner College of Medicine, University of Vermont, Burlington, VT, USA
| | - David A Kaminsky
- Larner College of Medicine, University of Vermont, Burlington, VT, USA
| | | | - Matthew E Poynter
- Larner College of Medicine, University of Vermont, Burlington, VT, USA
| | - Anne E Dixon
- Larner College of Medicine, University of Vermont, Burlington, VT, USA.
| |
Collapse
|
9
|
Połomska J, Bar K, Sozańska B. Exhaled Breath Condensate-A Non-Invasive Approach for Diagnostic Methods in Asthma. J Clin Med 2021; 10:jcm10122697. [PMID: 34207327 PMCID: PMC8235112 DOI: 10.3390/jcm10122697] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2021] [Revised: 06/04/2021] [Accepted: 06/15/2021] [Indexed: 01/08/2023] Open
Abstract
The pathophysiology of asthma has been intensively studied, but its underlying mechanisms such as airway inflammation, control of airway tone, and bronchial reactivity are still not completely explained. There is an urgent need to implement novel, non-invasive diagnostic tools that can help to investigate local airway inflammation and connect the molecular pathways with the broad spectrum of clinical manifestations of asthma. The new biomarkers of different asthma endotypes could be used to confirm diagnosis, predict asthma exacerbations, or evaluate treatment response. In this paper, we briefly describe the characteristics of exhaled breath condensate (EBC) that is considered to be an interesting source of biomarkers of lung disorders. We look at the composition of EBC, some aspects of the collection procedure, the proposed biomarkers for asthma, and its clinical implications. We also indicate the limitations of the method and potential strategies to standardize the procedure of EBC collection and analytical methods.
Collapse
|
10
|
Reference Ranges of 8-Isoprostane Concentrations in Exhaled Breath Condensate (EBC): A Systematic Review and Meta-Analysis. Int J Mol Sci 2020; 21:ijms21113822. [PMID: 32481492 PMCID: PMC7311981 DOI: 10.3390/ijms21113822] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2020] [Revised: 05/25/2020] [Accepted: 05/26/2020] [Indexed: 12/14/2022] Open
Abstract
Isoprostanes are physiopathologic mediators of oxidative stress, resulting in lipid peroxidation. 8-isoprostane seems particularly useful for measuring oxidative stress damage. However, no reference range values are available for 8-isoprosante in exhaled breath condensate (EBC) of healthy adults, enabling its meaningful interpretation as a biomarker. We conducted this systematic review and meta-analysis according to the protocol following PROSPERO (CRD42020146623). After searching and analyzing the literature, we included 86 studies. After their qualitative synthesis and risk of bias assessment, 52 studies were included in meta-analysis. The latter focused on studies using immunological analytical methods and investigated how the concentrations of 8-isoprostane differ based on gender. We found that gender had no significant effect in 8-isoprostane concentration. Among other studied factors, such as individual characteristics and factors related to EBC collection, only the device used for EBC collection significantly affected measured 8-isoprostane concentrations. However, adjustment for the factors related to EBC collection, yielded uncertainty whether this effect is due to the device itself or to the other factors. Given this uncertainty, we estimated the reference range values of 8-isoprostane stratified by gender and EBC collection device. A better standardization of EBC collection seems necessary; as well more studies using chemical analytical methods to extend this investigation.
Collapse
|
11
|
Jin Z, Zhang W, Zhu M, Xu J, Deng G, Wang D. Assessment of ventilator-associated pneumonia by combining 8-isoprostane and nitric oxide levels in exhaled breath condensate with the clinical pulmonary infection score. J Int Med Res 2020; 48:300060520922472. [PMID: 32419545 PMCID: PMC7235666 DOI: 10.1177/0300060520922472] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
Objective To investigate the effectiveness of combining the 8-isoprostane and nitric oxide (NO) levels in exhaled breath condensate (EBC) with the clinical pulmonary infection score (CPIS) to assess ventilator-associated pneumonia (VAP) in patients on mechanical ventilation. Methods Thirty-two patients with VAP served as the observation group and 32 patients without VAP served as the control group. The correlations of 8-isoprostane and NO levels in EBC with CPIS, chest X-ray score, oxygenation index, and lung injury score (LIS) were analyzed. The area under the curve (AUC) was compared with experimental data using the receiver operating characteristic curve (ROC) to predict VAP. Results The 8-isoprostane and NO levels in EBC of VAP patients on mechanical ventilation were positively correlated with CPIS, chest X-ray score, and LIS, but negatively correlated with oxygenation index. The AUC of simplified CPIS combined with 8-isoprostane and NO levels in EBC for predicting VAP was 0.914, which suggests that this is a highly effective for making a diagnosis. Conclusions The simplified CPIS combined with the 8-isoprostane and NO levels in EBC of patients on mechanical ventilation is effective for evaluating and diagnosing VAP. 8-Isoprostane and NO levels in EBC could be used as biomarkers to evaluate VAP.
Collapse
Affiliation(s)
- Zhaoquan Jin
- Emergency Department, The Third Affiliated Hospital of Soochow University, The First People's Hospital of Changzhou, Changzhou, Jiangsu, China
| | - Wenbin Zhang
- Emergency Department, The Third Affiliated Hospital of Soochow University, The First People's Hospital of Changzhou, Changzhou, Jiangsu, China
| | - Minghui Zhu
- Emergency Department, The Third Affiliated Hospital of Soochow University, The First People's Hospital of Changzhou, Changzhou, Jiangsu, China
| | - Juxian Xu
- Emergency Department, The Third Affiliated Hospital of Soochow University, The First People's Hospital of Changzhou, Changzhou, Jiangsu, China
| | - Guohua Deng
- Emergency Department, The Third Affiliated Hospital of Soochow University, The First People's Hospital of Changzhou, Changzhou, Jiangsu, China
| | - Daming Wang
- Emergency Department, The Third Affiliated Hospital of Soochow University, The First People's Hospital of Changzhou, Changzhou, Jiangsu, China
| |
Collapse
|
12
|
Development and validation of exhaled breath condensate microRNAs to identify and endotype asthma in children. PLoS One 2019; 14:e0224983. [PMID: 31703106 PMCID: PMC6839869 DOI: 10.1371/journal.pone.0224983] [Citation(s) in RCA: 26] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2019] [Accepted: 10/26/2019] [Indexed: 12/26/2022] Open
Abstract
Detection and quantification of microRNAs (miRNAs) in exhaled breath condensate (EBC) has been poorly explored. Therefore we aimed to assess miRNAs in EBC as potential biomarkers to diagnose and endotype asthma in school aged children. In a cross sectional, nested case control study, all the asthmatic children (n = 71) and a random sample of controls (n = 115), aged 7 to 12 years, attending 71 classrooms from 20 local schools were selected and arbitrarily allocated to the development or validation set. Participants underwent skin-prick testing, spirometry with bronchodilation, had exhaled level of nitric oxide determined and EBC collected. Based on previous studies eleven miRNAs were chosen and analyzed in EBC by reverse transcription-quantitative real-time PCR. Principal component analysis was applied to identify miRNAs profiles and associations were estimated using regression models. In the development set (n = 89) two clusters of miRNAs were identified. After adjustments, cluster 1 and three of its clustered miRNAs, miR-126-3p, miR-133a-3p and miR-145-5p were positively associated with asthma. Moreover miR-21-5p was negatively associated with symptomatic asthma and positively associated with positive bronchodilation without symptoms. An association was also found between miR-126-3p, cluster 2 and one of its clustered miRNA, miR-146-5p, with higher FEF25-75 reversibility. These findings were confirmed in the validation set (n = 97) where two identical clusters of miRNAs were identified. Additional significant associations were observed between miR-155-5p with symptomatic asthma, negative bronchodilation with symptoms and positive bronchodilation without symptoms. We showed that microRNAs can be measured in EBC of children and may be used as potential biomarkers of asthma, assisting asthma endotype establishment.
Collapse
|
13
|
Taniselass S, Arshad MM, Gopinath SC. Graphene-based electrochemical biosensors for monitoring noncommunicable disease biomarkers. Biosens Bioelectron 2019; 130:276-292. [DOI: 10.1016/j.bios.2019.01.047] [Citation(s) in RCA: 134] [Impact Index Per Article: 26.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2018] [Revised: 01/16/2019] [Accepted: 01/18/2019] [Indexed: 02/07/2023]
|
14
|
Hayton C, Terrington D, Wilson AM, Chaudhuri N, Leonard C, Fowler SJ. Breath biomarkers in idiopathic pulmonary fibrosis: a systematic review. Respir Res 2019; 20:7. [PMID: 30634961 PMCID: PMC6329167 DOI: 10.1186/s12931-019-0971-8] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2018] [Accepted: 01/01/2019] [Indexed: 01/07/2023] Open
Abstract
BACKGROUND Exhaled biomarkers may be related to disease processes in idiopathic pulmonary fibrosis (IPF) however their clinical role remains unclear. We performed a systematic review to investigate whether breath biomarkers discriminate between patients with IPF and healthy controls. We also assessed correlation with lung function, ability to distinguish diagnostic subgroups and change in response to treatment. METHODS MEDLINE, EMBASE and Web of Science databases were searched. Study selection was limited to adults with a diagnosis of IPF as per international guidelines. RESULTS Of 1014 studies screened, fourteen fulfilled selection criteria and included 257 IPF patients. Twenty individual biomarkers discriminated between IPF and controls and four showed correlation with lung function. Meta-analysis of three studies indicated mean (± SD) alveolar nitric oxide (CalvNO) levels were significantly higher in IPF (8.5 ± 5.5 ppb) than controls (4.4 ± 2.2 ppb). Markers of oxidative stress in exhaled breath condensate, such as hydrogen peroxide and 8-isoprostane, were also discriminatory. Two breathomic studies have isolated discriminative compounds using mass spectrometry. There was a lack of studies assessing relevant treatment and none assessed differences in diagnostic subgroups. CONCLUSIONS Evidence suggests CalvNO is higher in IPF, although studies were limited by small sample size. Further breathomic work may identify biomarkers with diagnostic and prognostic potential.
Collapse
Affiliation(s)
- Conal Hayton
- Division of Infection, Immunity and Respiratory Medicine, School of Biological Sciences, Faculty of Biology, Medicine and Health, The University of Manchester, Manchester, UK.
- North West Lung Centre, Manchester University NHS Foundation Trust, Manchester, UK.
| | | | - Andrew M Wilson
- Norwich Medical School, University of East Anglia, Norwich, UK
| | - Nazia Chaudhuri
- North West Lung Centre, Manchester University NHS Foundation Trust, Manchester, UK
| | - Colm Leonard
- North West Lung Centre, Manchester University NHS Foundation Trust, Manchester, UK
| | - Stephen J Fowler
- Division of Infection, Immunity and Respiratory Medicine, School of Biological Sciences, Faculty of Biology, Medicine and Health, The University of Manchester, Manchester, UK
- North West Lung Centre, Manchester University NHS Foundation Trust, Manchester, UK
| |
Collapse
|
15
|
Peterová E, Chládek J, Kohoutová D, Knoblochová V, Morávková P, Vávrová J, Řezáčová M, Bureš J. Exhaled Breath Condensate: Pilot Study of the Method and Initial Experience in Healthy Subjects. ACTA MEDICA (HRADEC KRÁLOVÉ) 2018; 61:8-16. [PMID: 30012244 DOI: 10.14712/18059694.2018.17] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
Abstract
Analysis of Exhaled breath condensate (EBC) is a re-discovered approach to monitoring the course of the disease and reduce invasive methods of patient investigation. However, the major disadvantage and shortcoming of the EBC is lack of reliable and reproducible standardization of the method. Despite many articles published on EBC, until now there is no clear consensus on whether the analysis of EBC can provide a clue to diagnosis of the diseases. The purpose of this paper is to investigate our own method, to search for possible standardization and to obtain our own initial experience. Thirty healthy volunteers provided the EBC, in which we monitored the density, pH, protein, chloride and urea concentration. Our results show that EBC pH is influenced by smoking, and urea concentrations are affected by the gender of subjects. Age of subjects does not play a role. The smallest coefficient of variation between individual volunteers is for density determination. Current limitations of EBC measurements are the low concentration of many biomarkers. Standardization needs to be specific for each individual biomarker, with focusing on optimal condensate collection. EBC analysis has a potential become diagnostic test, not only for lung diseases.
Collapse
Affiliation(s)
- Eva Peterová
- 2nd Department of Internal Medicine - Gastroenterology, Charles University, Faculty of Medicine in Hradec Králové, University Hospital Hradec Králové, Czech Republic. .,Department of Medical Biochemistry, Charles University, Faculty of Medicine in Hradec Králové, Czech Republic.
| | - Jaroslav Chládek
- Department of Pharmacology, Charles University, Faculty of Medicine in Hradec Králové, Czech Republic
| | - Darina Kohoutová
- 2nd Department of Internal Medicine - Gastroenterology, Charles University, Faculty of Medicine in Hradec Králové, University Hospital Hradec Králové, Czech Republic
| | - Veronika Knoblochová
- 2nd Department of Internal Medicine - Gastroenterology, Charles University, Faculty of Medicine in Hradec Králové, University Hospital Hradec Králové, Czech Republic
| | - Paula Morávková
- 2nd Department of Internal Medicine - Gastroenterology, Charles University, Faculty of Medicine in Hradec Králové, University Hospital Hradec Králové, Czech Republic
| | - Jaroslava Vávrová
- Institute of Clinical Biochemistry and Diagnostics, Charles University, Faculty of Medicine in Hradec Králové, University Hospital Hradec Králové, Czech Republic
| | - Martina Řezáčová
- Department of Medical Biochemistry, Charles University, Faculty of Medicine in Hradec Králové, Czech Republic
| | - Jan Bureš
- 2nd Department of Internal Medicine - Gastroenterology, Charles University, Faculty of Medicine in Hradec Králové, University Hospital Hradec Králové, Czech Republic
| |
Collapse
|
16
|
Jesenak M, Zelieskova M, Babusikova E. Oxidative Stress and Bronchial Asthma in Children-Causes or Consequences? Front Pediatr 2017; 5:162. [PMID: 28791280 PMCID: PMC5523023 DOI: 10.3389/fped.2017.00162] [Citation(s) in RCA: 55] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/05/2017] [Accepted: 07/06/2017] [Indexed: 12/13/2022] Open
Abstract
Bronchial asthma is one of the most common chronic inflammatory diseases of the airways. In the pathogenesis of this disease, the interplay among the genes, intrinsic, and extrinsic factors are crucial. Various combinations of the involved factors determine and modify the final clinical phenotype/endotype of asthma. Oxidative stress results from an imbalance between the production of reactive oxygen species and reactive nitrogen species and the capacity of antioxidant defense mechanisms. It was shown that oxidative damage of biomolecules is strongly involved in the asthmatic inflammation. It is evident that asthma is accompanied by oxidative stress in the airways and in the systemic circulation. The oxidative stress is more pronounced during the acute exacerbation or allergen challenge. On the other hand, the genetic variations in the genes for anti-oxidative and pro-oxidative enzymes are variably associated with various asthmatic subtypes. Whether oxidative stress is the consequence of, or the cause for, chronic changes in asthmatic airways is still being discussed. Contribution of oxidative stress to asthma pathology remains at least partially controversial, since antioxidant interventions have proven rather unsuccessful. According to current knowledge, the relationship between oxidative stress and asthmatic inflammation is bidirectional, and genetic predisposition could modify the balance between these two positions-oxidative stress as a cause for or consequence of asthmatic inflammation.
Collapse
Affiliation(s)
- Milos Jesenak
- Jessenius Faculty of Medicine, Department of Pediatrics, Comenius University in Bratislava, University Hospital, Martin, Slovakia
| | - Maria Zelieskova
- Jessenius Faculty of Medicine, Department of Pediatrics, Comenius University in Bratislava, University Hospital, Martin, Slovakia
| | - Eva Babusikova
- Jessenius Faculty of Medicine, Department of Medical Biochemistry, Comenius University in Bratislava, Martin, Slovakia
| |
Collapse
|