1
|
Cano Perez JL, Gutiérrez-Gutiérrez J, Perezcampos Mayoral C, Pérez-Campos EL, Pina Canseco MDS, Tepech Carrillo L, Mayoral LPC, Vargas Treviño M, Apreza EL, Rojas Laguna R. Fiber Optic Sensors: A Review for Glucose Measurement. BIOSENSORS 2021; 11:61. [PMID: 33669087 PMCID: PMC7996499 DOI: 10.3390/bios11030061] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/09/2021] [Revised: 02/20/2021] [Accepted: 02/22/2021] [Indexed: 12/27/2022]
Abstract
Diabetes mellitus is a chronic metabolic disorder, being globally one of the most deadly diseases. This disease requires continually monitoring of the body's glucose levels. There are different types of sensors for measuring glucose, most of them invasive to the patient. Fiber optic sensors have been proven to have advantages compared to conventional sensors and they have great potential for various applications, especially in the biomedical area. Compared to other sensors, they are smaller, easy to handle, mostly non-invasive, thus leading to a lower risk of infection, high precision, well correlated and inexpensive. The objective of this review article is to compare different types of fiber optic sensors made with different experimental techniques applied to biomedicine, especially for glucose sensing. Observations are made on the way of elaboration, as well as the advantages and disadvantages that each one could have in real applications.
Collapse
Affiliation(s)
- José Luis Cano Perez
- Doctorado in Biociencias, Facultad de Medicina y Cirugia, Universidad Autónoma “Benito Juárez” de Oaxaca. Ex Hacienda de Aguilera S/N, Calz. San Felipe del Agua, Oaxaca de Juárez 68120, Mexico;
| | - Jaime Gutiérrez-Gutiérrez
- Escuela de Sistemas Biologicos e Innovacion Tecnologica, Universidad Autónoma “Benito Juárez” de Oaxaca (ESBIT-UABJO), Av. Universidad S/N, Ex-Hacienda 5 Señores, Oaxaca de Juárez 68120, Mexico; (L.T.C.); (M.V.T.); (E.L.A.)
| | - Christian Perezcampos Mayoral
- Doctorado in Biociencias, Facultad de Medicina y Cirugia, Universidad Autónoma “Benito Juárez” de Oaxaca. Ex Hacienda de Aguilera S/N, Calz. San Felipe del Agua, Oaxaca de Juárez 68120, Mexico;
| | - Eduardo L. Pérez-Campos
- Facultad de Medicina y Cirugia, Universidad Autónoma “Benito Juárez” de Oaxaca. Ex Hacienda de Aguilera S/N, Calz. San Felipe del Agua, Oaxaca de Juárez 68120, Mexico; (E.L.P.-C.); (M.d.S.P.C.); (L.P.-C.M.)
| | - Maria del Socorro Pina Canseco
- Facultad de Medicina y Cirugia, Universidad Autónoma “Benito Juárez” de Oaxaca. Ex Hacienda de Aguilera S/N, Calz. San Felipe del Agua, Oaxaca de Juárez 68120, Mexico; (E.L.P.-C.); (M.d.S.P.C.); (L.P.-C.M.)
| | - Lorenzo Tepech Carrillo
- Escuela de Sistemas Biologicos e Innovacion Tecnologica, Universidad Autónoma “Benito Juárez” de Oaxaca (ESBIT-UABJO), Av. Universidad S/N, Ex-Hacienda 5 Señores, Oaxaca de Juárez 68120, Mexico; (L.T.C.); (M.V.T.); (E.L.A.)
| | - Laura Pérez-Campos Mayoral
- Facultad de Medicina y Cirugia, Universidad Autónoma “Benito Juárez” de Oaxaca. Ex Hacienda de Aguilera S/N, Calz. San Felipe del Agua, Oaxaca de Juárez 68120, Mexico; (E.L.P.-C.); (M.d.S.P.C.); (L.P.-C.M.)
| | - Marciano Vargas Treviño
- Escuela de Sistemas Biologicos e Innovacion Tecnologica, Universidad Autónoma “Benito Juárez” de Oaxaca (ESBIT-UABJO), Av. Universidad S/N, Ex-Hacienda 5 Señores, Oaxaca de Juárez 68120, Mexico; (L.T.C.); (M.V.T.); (E.L.A.)
| | - Edmundo López Apreza
- Escuela de Sistemas Biologicos e Innovacion Tecnologica, Universidad Autónoma “Benito Juárez” de Oaxaca (ESBIT-UABJO), Av. Universidad S/N, Ex-Hacienda 5 Señores, Oaxaca de Juárez 68120, Mexico; (L.T.C.); (M.V.T.); (E.L.A.)
| | - Roberto Rojas Laguna
- Division de Ingenierias, Campus Irapuato-Salamanca, Universidad de Guanajuato, Carretera Salamanca-Valle de Santiago km 3.5 + 1.8, Comunidad de Palo Blanco, Salamanca 36885, Mexico;
| |
Collapse
|
2
|
Liu Y, Salemink HWM. Real-time dynamic sensing with an on-chip nanophotonic sensor. OPTICS EXPRESS 2017; 25:17201-17210. [PMID: 28789214 DOI: 10.1364/oe.25.017201] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/06/2016] [Accepted: 01/18/2017] [Indexed: 06/07/2023]
Abstract
We demonstrate a nanophotonic sensor for real-time monitoring of fluid flows. The sensor is based on a silicon photonic crystal cavity with a well aligned micro fluidic channel for fluid-injection. The simulated resonant wavelength shift of the sensor with residual oil in holes is 9.0 nm, and the observed experimental shift under the same condition is 10.0 nm. An alternating fluid delivery is applied in a dynamic sensing experiment with syringe pump controlled ratios of water and oil. Excellent agreement between the measured data and the video images of fluidic streams in the optofluidic cell is found.
Collapse
|
3
|
Brooks WLA, Sumerlin BS. Synthesis and Applications of Boronic Acid-Containing Polymers: From Materials to Medicine. Chem Rev 2015; 116:1375-97. [DOI: 10.1021/acs.chemrev.5b00300] [Citation(s) in RCA: 552] [Impact Index Per Article: 61.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/17/2023]
Affiliation(s)
- William L. A. Brooks
- George & Josephine Butler Polymer Research Laboratory, Center for Macromolecular Science & Engineering, Department of Chemistry, University of Florida, Gainesville, Florida 32611-7200, United States
| | - Brent S. Sumerlin
- George & Josephine Butler Polymer Research Laboratory, Center for Macromolecular Science & Engineering, Department of Chemistry, University of Florida, Gainesville, Florida 32611-7200, United States
| |
Collapse
|
4
|
Hansen JS, Christensen JB. Recent advances in fluorescent arylboronic acids for glucose sensing. BIOSENSORS 2013; 3:400-18. [PMID: 25586415 PMCID: PMC4263566 DOI: 10.3390/bios3040400] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/24/2013] [Revised: 11/13/2013] [Accepted: 12/02/2013] [Indexed: 01/08/2023]
Abstract
Continuous glucose monitoring (CGM) is crucial in order to avoid complications caused by change in blood glucose for patients suffering from diabetes mellitus. The long-term consequences of high blood glucose levels include damage to the heart, eyes, kidneys, nerves and other organs, among others, caused by malign glycation of vital protein structures. Fluorescent monitors based on arylboronic acids are promising candidates for optical CGM, since arylboronic acids are capable of forming arylboronate esters with 1,2-cis-diols or 1,3-diols fast and reversibly, even in aqueous solution. These properties enable arylboronic acid dyes to provide immediate information of glucose concentrations. Thus, the replacement of the commonly applied semi-invasive and non-invasive techniques relying on glucose binding proteins, such as concanavalin A, or enzymes, such as glucose oxidase, glucose dehydrogenase and hexokinases/glucokinases, might be possible. The recent progress in the development of fluorescent arylboronic acid dyes will be emphasized in this review.
Collapse
Affiliation(s)
- Jon Stefan Hansen
- Department of Chemistry, University of Copenhagen, Thorvaldsensvej 40, DK-1871 Frederiksberg C, Copenhagen, Denmark.
| | - Jørn Bolstad Christensen
- Department of Chemistry, University of Copenhagen, Thorvaldsensvej 40, DK-1871 Frederiksberg C, Copenhagen, Denmark.
| |
Collapse
|
5
|
Guan Y, Zhang Y. Boronic acid-containing hydrogels: synthesis and their applications. Chem Soc Rev 2013; 42:8106-21. [DOI: 10.1039/c3cs60152h] [Citation(s) in RCA: 313] [Impact Index Per Article: 28.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
|
6
|
|
7
|
A unique, two-component sensing system for fluorescence detection of glucose and other carbohydrates. PURE APPL CHEM 2012. [DOI: 10.1351/pac-con-11-10-36] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
In our glucose-sensing system, a boronic acid-modified viologen molecule quenches the fluorescence of a separate dye molecule. When glucose or other monosaccharides are added and bind to the boronic acid, the quenching ability of the viologen is diminished and fluorescence increases. Thus, changes in the fluorescence of the dye can be correlated with changing glucose concentration. Quenching and sugar-sensing results are explained by an electrostatic interaction between dye and quencher. This modular system can be configured in a nearly unlimited number of ways through substitution and multiplexing of the two fundamental quencher and dye components. Significantly, fluorescent quantum dots (QDs) can also be used as the reporter component. The system can also be immobilized in a hydrogel polymer to provide real-time, reversible sugar sensing.
Collapse
|
8
|
Bratlie KM, York RL, Invernale MA, Langer R, Anderson DG. Materials for diabetes therapeutics. Adv Healthc Mater 2012; 1:267-84. [PMID: 23184741 PMCID: PMC3899887 DOI: 10.1002/adhm.201200037] [Citation(s) in RCA: 115] [Impact Index Per Article: 9.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2012] [Indexed: 11/10/2022]
Abstract
This review is focused on the materials and methods used to fabricate closed-loop systems for type 1 diabetes therapy. Herein, we give a brief overview of current methods used for patient care and discuss two types of possible treatments and the materials used for these therapies-(i) artificial pancreases, comprised of insulin producing cells embedded in a polymeric biomaterial, and (ii) totally synthetic pancreases formulated by integrating continuous glucose monitors with controlled insulin release through degradable polymers and glucose-responsive polymer systems. Both the artificial and the completely synthetic pancreas have two major design requirements: the device must be both biocompatible and be permeable to small molecules and proteins, such as insulin. Several polymers and fabrication methods of artificial pancreases are discussed: microencapsulation, conformal coatings, and planar sheets. We also review the two components of a completely synthetic pancreas. Several types of glucose sensing systems (including materials used for electrochemical, optical, and chemical sensing platforms) are discussed, in addition to various polymer-based release systems (including ethylene-vinyl acetate, polyanhydrides, and phenylboronic acid containing hydrogels).
Collapse
Affiliation(s)
- Kaitlin M. Bratlie
- The Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, 32 Vassar St., Cambridge, MA 02142, USA
- Department of Anesthesiology, Children’s Hospital Boston, 300 Longwood Avenue, Boston, MA 02115, USA
- Department of Chemical Engineering, Massachusetts Institute of Technology, 77 Massachusetts Avenue, Cambridge, MA 02139, USA
| | - Roger L. York
- The Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, 32 Vassar St., Cambridge, MA 02142, USA
- Department of Anesthesiology, Children’s Hospital Boston, 300 Longwood Avenue, Boston, MA 02115, USA
| | - Michael A. Invernale
- The Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, 32 Vassar St., Cambridge, MA 02142, USA
- Department of Anesthesiology, Children’s Hospital Boston, 300 Longwood Avenue, Boston, MA 02115, USA
| | - Robert Langer
- The Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, 32 Vassar St., Cambridge, MA 02142, USA
- Department of Anesthesiology, Children’s Hospital Boston, 300 Longwood Avenue, Boston, MA 02115, USA
- Department of Chemical Engineering, Massachusetts Institute of Technology, 77 Massachusetts Avenue, Cambridge, MA 02139, USA
- Harvard-MIT Division of Health Science Technology, Massachusetts Institute of Technology, 45 Carleton Street, Building E25-342, Cambridge, MA 02142, USA
| | - Daniel G. Anderson
- The Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, 32 Vassar St., Cambridge, MA 02142, USA
- Department of Anesthesiology, Children’s Hospital Boston, 300 Longwood Avenue, Boston, MA 02115, USA
- Department of Chemical Engineering, Massachusetts Institute of Technology, 77 Massachusetts Avenue, Cambridge, MA 02139, USA
- Harvard-MIT Division of Health Science Technology, Massachusetts Institute of Technology, 45 Carleton Street, Building E25-342, Cambridge, MA 02142, USA
| |
Collapse
|
9
|
Going Beyond Continuous Glucose Monitoring with Boronic Acid-Appended Bipyridinium Salts. ACTA ACUST UNITED AC 2011. [DOI: 10.1007/978-1-4419-9672-5_7] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/19/2023]
|
10
|
|
11
|
|
12
|
Mader HS, Wolfbeis OS. Boronic acid based probes for microdetermination of saccharides and glycosylated biomolecules. Mikrochim Acta 2008. [DOI: 10.1007/s00604-008-0947-8] [Citation(s) in RCA: 163] [Impact Index Per Article: 10.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
13
|
Yu B, Wang C, Ju YM, West L, Harmon J, Moussy Y, Moussy F. Use of hydrogel coating to improve the performance of implanted glucose sensors. Biosens Bioelectron 2008; 23:1278-84. [DOI: 10.1016/j.bios.2007.11.010] [Citation(s) in RCA: 70] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2007] [Revised: 10/30/2007] [Accepted: 11/21/2007] [Indexed: 10/22/2022]
|
14
|
Bhattacharyya D, Pillai K, Chyan OMR, Tang L, Timmons RB. A NEW CLASS OF THIN FILM HYDROGELS PRODUCED BY PLASMA POLYMERIZATION. CHEMISTRY OF MATERIALS : A PUBLICATION OF THE AMERICAN CHEMICAL SOCIETY 2007; 19:2222-2228. [PMID: 19079730 PMCID: PMC2600724 DOI: 10.1021/cm0630688] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
A simple, direct route to preparation of surface immobilized hydrogel films is described. Specifically, low pressure RF pulsed plasma polymerization of 1-amino-2-propanol and 2-(ethylamino)ethanol monomers produced thin hydrogel films deposited on substrates located in the plasma reactor. The successful syntheses were carried out under plasma conditions which not only yield the hydrogel but are also sufficiently energetic to produce films strongly grafted to the substrates. The polymer films obtained exhibit the thermoresponsive property of hydrogels, as shown by film color change with temperature. Additional evidence for the phase transition properties of these films was obtained using water contact angle and capillary rise measurements. The plasma polymerization approach provides an unusually simple route to synthesis of hydrogels in which the films are pin-hole free and are of easily controlled thickness. An important added advantage, particularly for applications involving biomaterials, is the conformal property of the plasma generated polymer films. The results obtained suggest that this approach should be applicable to a variety of other monomers and, based on differences observed with the present two monomers, suggest synthesis of films which exhibit a range of phase transition temperatures.
Collapse
Affiliation(s)
- Dhiman Bhattacharyya
- Department of Chemistry and Biochemistry, University of Texas at Arlington, Arlington, TX – 76019-0065
| | | | | | - Liping Tang
- Department of Bioengineering, University of Texas at Arlington, Arlington, TX – 76019-0138
| | - Richard B. Timmons
- Department of Chemistry and Biochemistry, University of Texas at Arlington, Arlington, TX – 76019-0065
| |
Collapse
|
15
|
Zhang T, Anslyn EV. Using an Indicator Displacement Assay to Monitor Glucose Oxidase Activity in Blood Serum. Org Lett 2007; 9:1627-9. [PMID: 17391039 DOI: 10.1021/ol070280o] [Citation(s) in RCA: 52] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
[diagram: see text] Using a boronic acid receptor that was previously found to have high affinity for gluconic acid, we created a colorimetric indicator displacement assay (IDA) that can report the concentration of the product of glucose oxidase (GOx) catalyzed glucose oxidation. The color change obtained directly reflects the concentration of glucose. Our sensing ensemble was then successfully applied to determine the glucose concentration in human serum, which offers a facile, colorimetric, sensitive, and accurate glucose test.
Collapse
Affiliation(s)
- Tianzhi Zhang
- Department of Chemistry and Biochemistry, 1 University Station A5300, The University of Texas, Austin, Texas 78712, USA
| | | |
Collapse
|
16
|
Kondepati VR, Heise HM. Recent progress in analytical instrumentation for glycemic control in diabetic and critically ill patients. Anal Bioanal Chem 2007; 388:545-63. [PMID: 17431594 DOI: 10.1007/s00216-007-1229-8] [Citation(s) in RCA: 54] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2006] [Revised: 02/16/2007] [Accepted: 02/22/2007] [Indexed: 01/08/2023]
Abstract
Implementing strict glycemic control can reduce the risk of serious complications in both diabetic and critically ill patients. For this reason, many different analytical, mainly electrochemical and optical sensor approaches for glucose measurements have been developed. Self-monitoring of blood glucose (SMBG) has been recognised as being an indispensable tool for intensive diabetes therapy. Recent progress in analytical instrumentation, allowing submicroliter samples of blood, alternative site testing, reduced test time, autocalibration, and improved precision, is comprehensively described in this review. Continuous blood glucose monitoring techniques and insulin infusion strategies, developmental steps towards the realization of the dream of an artificial pancreas under closed loop control, are presented. Progress in glucose sensing and glycemic control for both patient groups is discussed by assessing recent published literature (up to 2006). The state-of-the-art and trends in analytical techniques (either episodic, intermittent or continuous, minimal-invasive, or noninvasive) detailed in this review will provide researchers, health professionals and the diabetic community with a comprehensive overview of the potential of next-generation instrumentation suited to either short- and long-term implantation or ex vivo measurement in combination with appropriate body interfaces such as microdialysis catheters.
Collapse
Affiliation(s)
- Venkata Radhakrishna Kondepati
- ISAS--Institute for Analytical Sciences at the University of Dortmund, Bunsen-Kirchhoff-Strasse 11, 44139, Dortmund, Germany
| | | |
Collapse
|