1
|
Zanfardino A, Bruzzi P, Trada M, Rapini N, Laudani E, Tornese G, Ortolani F, Piccolo G, Matonti L, Saltarelli MA, Timpanaro T, D'Annunzio G, Predieri B, Rossi F, Mura R, Barat V, Prete A, Schiaffini R, Zucchini S. The real-life management of glucose homeostasis abnormalities in pediatric onco-hematological diseases: data from a national survey. Pediatr Hematol Oncol 2024; 41:198-210. [PMID: 38269620 DOI: 10.1080/08880018.2023.2295454] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/26/2023] [Accepted: 12/09/2023] [Indexed: 01/26/2024]
Abstract
Glycemic abnormalities are a frequent finding in pediatric oncological patients, both during treatment and after its discontinuation. Moreover, impaired glucose tolerance (IGT), impaired fasting glycemia (IFG) and diabetes mellitus (DM) are not rarely diagnosed in non-oncological hematological diseases. To explore the current pediatric Italian approach to the diagnosis and the management of the glycemic alterations in this clinical setting and, thus, to identify and enforce current clinical needs, we submitted an online 23-items survey to all the Italian Associazione Italiana Ematologia Oncologia Pediatrica (AIEOP) centers, and surveys were descriptively analyzed. Thirty-nine AIEOP centers were involved in the study. In 2021, among 75278 children and adolescents affected by an oncological or a hematological disease, 1.2 and 0.65% developed DM, while IGT or IFG were widespread in 2.3 and 2.8%, respectively. The main causes of DM were the use of corticosteroids in patients with cancer and the iron overload in patients with thalassemia. Venous fasting plasma glycemia was the most used tool to detect glycemic abnormalities. The performance of oral glucose tolerance test (OGTT) was extremely limited, except when IFG occurred. Despite the diagnosis of DM, ∼45% of patients with cancer and 30% of patients with one hematological disease did not receive an appropriate treatment. In the other cases, insulin was the drug of first choice. Emerging technologies for diabetes care (glucose sensors and insulin pumps) are not largely used yet. The results of our study support the standardization of the care of the glycemic abnormalities during or after onco-hematologic diseases in the pediatric age. Despite the scarce data in pediatric literature, proper guidelines are needed.
Collapse
Affiliation(s)
| | - Patrizia Bruzzi
- Paediatric Unit, Department of Medical and Surgical Sciences of Mothers, Children and Adults, University of Modena & Reggio Emilia, Modena, Italy
| | - Michela Trada
- Center of Pediatric Diabetology-A.O.U. Città della Salute e della Scienza di Torino, Turin, Italy
| | - Novella Rapini
- Diabetology and Growth Disorders Unit, Bambino Gesù Children's Hospital, IRCCS, Rome, Italy
| | - Emanuela Laudani
- Department of Health Sciences, University of Florence, Florence, Italy
| | - Gianluca Tornese
- Institute for Maternal and Child Health, IRCCS Burlo Garofolo, Trieste, Italy
| | - Federica Ortolani
- Department of Metabolic Diseases, Clinical Genetics and Diabetology, Giovanni XXIII Children's Hospital, Bari, Italy
| | - Gianluca Piccolo
- Pediatric Clinic and Endocrinology, Regional Center for Pediatric Diabetes, IRCCS Istituto Giannina Gaslini, Genoa, Italy
| | - Lorena Matonti
- Department of Pediatrics, University of Chieti, Chieti, Italy
| | | | | | - Giuseppe D'Annunzio
- Pediatric Clinic and Endocrinology, Regional Center for Pediatric Diabetes, IRCCS Istituto Giannina Gaslini, Genoa, Italy
| | - Barbara Predieri
- Paediatric Unit, Department of Medical and Surgical Sciences of Mothers, Children and Adults, University of Modena & Reggio Emilia, Modena, Italy
| | | | - Rossella Mura
- Department of Paediatric Haematology-Oncology, Ospedale Pediatrico Microcitemico, Cagliari, Italy
| | - Veronica Barat
- SC Onco-Ematologia Pediatrica, AOU Città della Salute e della Scienza, Turin, Italy
| | - Arcangelo Prete
- Pediatric Oncohematology Unit, IRCCS Azienda Ospedaliero-Universitaria di Bologna, Bologna, Italy
| | - Riccardo Schiaffini
- Diabetology and Growth Disorders Unit, Bambino Gesù Children's Hospital, IRCCS, Rome, Italy
| | - Stefano Zucchini
- Coordinator of the Diabetes Study Group of the Italian Society for Pediatric Endocrinology and Diabetes (ISPED), Bologna, Italy
| |
Collapse
|
2
|
Cobry EC, Pyle L, Waterman LA, Forlenza GP, Towers L, Karami AJ, Jost E, Berget C, Wadwa RP. Accuracy of a Continuous Glucose Monitor During Pediatric Type 1 Diabetes Inpatient Admissions. Diabetes Technol Ther 2024; 26:119-124. [PMID: 38194229 DOI: 10.1089/dia.2023.0375] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/10/2024]
Abstract
Objective: Continuous glucose monitors (CGMs) used for type 1 diabetes management are associated with lower hemoglobin A1c. CGMs are not approved for inpatient use, when close glucose monitoring and intensive insulin management are essential for optimal health. Accuracy data from adult hospitalizations have been published, but pediatric data are limited. Design and Methods: This retrospective review of Dexcom G6 data from youth with type 1 diabetes during hospitalization assessed CGMs and matched (within 5 min) point-of-care (POC) and laboratory glucose values. Glucose values >400 and <40 mg/dL were excluded due to sensor reporting capabilities. Standard methods for CGM accuracy were used including mean absolute relative difference (MARD), Clarke Error Grids, and percentage of CGM values within 15%/20%/30% if glucose value is >100 mg/dL and 15/20/30 mg/dL if value is ≤100 mg/dL. Results: A total of 1120 POC and 288 laboratory-matched pairs were collected from 83 unique patients (median age 12.0 years, 68.7% non-Hispanic white, 54.2% male) during 100 admissions. For POC values, overall, MARD was 11.8%, that on the medical floor was 13.5%, and that in the intensive care unit was 7.9%. The MARD for all laboratory values was 6.5%. In total, 98% of matched pairs were within Clarke Error Grid A and B zones. Conclusions: Findings from our pediatric population were similar to accuracy reported in hospitalized adults, indicating the potential role for CGM use during pediatric hospitalizations. Additional research is needed to assess accuracy under various conditions, including medication use, as well as development of safe hospital protocols for successful CGM implementation for routine inpatient care.
Collapse
Affiliation(s)
- Erin C Cobry
- Barbara Davis Center for Diabetes, University of Colorado Anschutz Medical Campus, Aurora, Colorado, USA
| | - Laura Pyle
- Barbara Davis Center for Diabetes, University of Colorado Anschutz Medical Campus, Aurora, Colorado, USA
- Department of Biostatistics and Informatics, Colorado School of Public Health, Aurora, Colorado, USA
| | - Lauren A Waterman
- Barbara Davis Center for Diabetes, University of Colorado Anschutz Medical Campus, Aurora, Colorado, USA
| | - Gregory P Forlenza
- Barbara Davis Center for Diabetes, University of Colorado Anschutz Medical Campus, Aurora, Colorado, USA
| | - Lindsey Towers
- Barbara Davis Center for Diabetes, University of Colorado Anschutz Medical Campus, Aurora, Colorado, USA
| | - Angela J Karami
- Barbara Davis Center for Diabetes, University of Colorado Anschutz Medical Campus, Aurora, Colorado, USA
| | - Emily Jost
- Barbara Davis Center for Diabetes, University of Colorado Anschutz Medical Campus, Aurora, Colorado, USA
| | - Cari Berget
- Barbara Davis Center for Diabetes, University of Colorado Anschutz Medical Campus, Aurora, Colorado, USA
| | - R Paul Wadwa
- Barbara Davis Center for Diabetes, University of Colorado Anschutz Medical Campus, Aurora, Colorado, USA
| |
Collapse
|
3
|
Tian T, Aaron RE, Seley JJ, Longo R, Nayberg I, Umpierrez GE, Levy CJ, Klonoff DC. Use of Continuous Glucose Monitors Upon Hospital Discharge of People With Diabetes: Promise, Barriers, and Opportunity. J Diabetes Sci Technol 2024; 18:207-214. [PMID: 37784246 PMCID: PMC10899827 DOI: 10.1177/19322968231200847] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/04/2023]
Abstract
Continuous glucose monitors (CGMs) have increasingly been used in ambulatory and inpatient or hospital settings to improve glycemic outcomes for people with diabetes. Given their capacity to aid individuals in avoiding hypo- and hyperglycemia, they may also be useful when transitioning from hospital to home by reducing rates of hospital readmissions and emergency department visits. Several types of barriers presently exist that make the deployment of CGMs at the time of hospital discharge problematic, including (1) regulatory, (2) behavioral, (3) logistical, (4) technical, (5) staffing, and (6) systemic issues. In this commentary, we review the literature, discuss these barriers, and propose possible solutions to facilitate the use of CGMs in people with diabetes at the time of hospital discharge.
Collapse
Affiliation(s)
- Tiffany Tian
- Diabetes Technology Society, Burlingame, CA, USA
| | | | - Jane Jeffrie Seley
- Division of Endocrinology, Diabetes & Metabolism, Weill Cornell Medicine, New York, NY, USA
| | - Rebecca Longo
- Lahey Hospital & Medical Center, Beth Israel Lahey Health, Burlington, MA, USA
| | - Irina Nayberg
- Diabetes Research Institute, Mills-Peninsula Medical Center, San Mateo, CA, USA
| | | | - Carol J. Levy
- Division of Endocrinology, Diabetes, and Metabolism, Icahn School of Medicine at Mount Sinai, New York, NY, USA
| | - David C. Klonoff
- Diabetes Research Institute, Mills-Peninsula Medical Center, San Mateo, CA, USA
| |
Collapse
|
4
|
Cho S, Vigers T, Pyle L, Franklin A, Sopfe J, Jeney F, Forlenza G. Composite Metric of Glycemic Control Q-Score Is Elevated in Pediatric and Adolescent/Young Adult Hematopoietic Stem Cell Transplant Recipients. Diabetes Technol Ther 2023; 25:116-121. [PMID: 36511871 PMCID: PMC9894599 DOI: 10.1089/dia.2022.0246] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Background: Malglycemia in pediatric, adolescent and young adult (AYA) patients who undergo hematopoietic stem cell transplant (HSCT) is associated with increased infection and mortality rate. Continuous glucose monitoring (CGM) has been safely used in pediatric/AYA HSCT recipients, but there is a need for a composite metric that can easily be used in clinical settings to assess the glycemic control and identify high-risk patients who needs therapeutic intervention. Composite metrics derived from CGM have not been studied in pediatric/AYA HSCT patients. Methods: Patients aged 2-30 years old who are admitted inpatient while undergoing HSCT at Children's Hospital Colorado underwent CGM using the Abbot Freestyle Libre Pro device from up to 7 days before and 60 days after HSCT. A composite metric Q-score, comprising five primary factors of CGM profiles (central tendency, hyperglycemia, hypoglycemia, intradaily variations, and interdaily variations), was calculated for each patient for the duration of CGM wear. Results: Twenty-nine patients received CGM for an average of 25 days per participant. The median Q-score was 10.2 (interquartile range [IQR]: 8.3, 14.3). Sixty-nine percent of patients had Q-scores that would be categorized into the Fair or Poor category. There was no difference in the Q-score by sources of stem cell, types of primary disease, types of preparative regimen, need for PICU admission, presence of documented infections, and total parenteral nutrition use in the peri-HSCT period. Conclusions: Most pediatric/AYA HSCT recipients have Q-scores indicating suboptimal glycemic control in the peri-HSCT period. Future study should focus on developing screening and treatment strategies to improve malglycemia and its associated adverse clinical outcomes. This study was registered at clinicaltrials.gov (NCT03482154).
Collapse
Affiliation(s)
- Soohee Cho
- Department of Pediatrics, University of Colorado Anschutz Medical Campus, Aurora, Colorado, USA
- Center for Cancer and Blood Disorder, Children's Hospital Colorado, Aurora, Colorado, USA
| | - Tim Vigers
- Department of Pediatrics, University of Colorado Anschutz Medical Campus, Aurora, Colorado, USA
- Department of Biostatistics and Informatics, Colorado School of Public Health, Auroa, Colorado, USA
| | - Laura Pyle
- Department of Pediatrics, University of Colorado Anschutz Medical Campus, Aurora, Colorado, USA
- Department of Biostatistics and Informatics, Colorado School of Public Health, Auroa, Colorado, USA
| | - Anna Franklin
- Department of Pediatrics, University of Colorado Anschutz Medical Campus, Aurora, Colorado, USA
- Center for Cancer and Blood Disorder, Children's Hospital Colorado, Aurora, Colorado, USA
| | - Jenna Sopfe
- Department of Pediatrics, University of Colorado Anschutz Medical Campus, Aurora, Colorado, USA
- Center for Cancer and Blood Disorder, Children's Hospital Colorado, Aurora, Colorado, USA
| | - Frankie Jeney
- Department of Pediatrics, University of Colorado Anschutz Medical Campus, Aurora, Colorado, USA
| | - Gregory Forlenza
- Department of Pediatrics, University of Colorado Anschutz Medical Campus, Aurora, Colorado, USA
- Barbara Davis Center for Childhood Diabetes, University of Colorado Anschutz Medical Campus, Aurora, Colorado, USA
| |
Collapse
|
5
|
Perez-Guzman MC, Shang T, Zhang JY, Jornsay D, Klonoff DC. Continuous Glucose Monitoring in the Hospital. Endocrinol Metab (Seoul) 2021; 36:240-255. [PMID: 33789033 PMCID: PMC8090458 DOI: 10.3803/enm.2021.201] [Citation(s) in RCA: 29] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/02/2021] [Accepted: 02/18/2021] [Indexed: 12/14/2022] Open
Abstract
Continuous glucose monitors (CGMs) have suddenly become part of routine care in many hospitals. The coronavirus disease 2019 (COVID-19) pandemic has necessitated the use of new technologies and new processes to care for hospitalized patients, including diabetes patients. The use of CGMs to automatically and remotely supplement or replace assisted monitoring of blood glucose by bedside nurses can decrease: the amount of necessary nursing exposure to COVID-19 patients with diabetes; the amount of time required for obtaining blood glucose measurements, and the amount of personal protective equipment necessary for interacting with patients during the blood glucose testing. The United States Food and Drug Administration (FDA) is now exercising enforcement discretion and not objecting to certain factory-calibrated CGMs being used in a hospital setting, both to facilitate patient care and to obtain performance data that can be used for future regulatory submissions. CGMs can be used in the hospital to decrease the frequency of fingerstick point of care capillary blood glucose testing, decrease hyperglycemic episodes, and decrease hypoglycemic episodes. Most of the research on CGMs in the hospital has focused on their accuracy and only recently outcomes data has been reported. A hospital CGM program requires cooperation of physicians, bedside nurses, diabetes educators, and hospital administrators to appropriately select and manage patients. Processes for collecting, reviewing, storing, and responding to CGM data must be established for such a program to be successful. CGM technology is advancing and we expect that CGMs will be increasingly used in the hospital for patients with diabetes.
Collapse
Affiliation(s)
- M. Citlalli Perez-Guzman
- Division of Endocrinology, Metabolism, and Lipids, Department of Medicine, Emory University, Atlanta, GA,
USA
| | - Trisha Shang
- Diabetes Technology Society, Burlingame, CA,
USA
| | | | - Donna Jornsay
- Diabetes Program, Mills-Peninsula Medical Center, Burlingame, CA,
USA
| | - David C. Klonoff
- Diabetes Research Institute, Mills-Peninsula Medical Center, San Mateo, CA,
USA
| |
Collapse
|
6
|
Galindo RJ, Umpierrez GE, Rushakoff RJ, Basu A, Lohnes S, Nichols JH, Spanakis EK, Espinoza J, Palermo NE, Awadjie DG, Bak L, Buckingham B, Cook CB, Freckmann G, Heinemann L, Hovorka R, Mathioudakis N, Newman T, O’Neal DN, Rickert M, Sacks DB, Seley JJ, Wallia A, Shang T, Zhang JY, Han J, Klonoff DC. Continuous Glucose Monitors and Automated Insulin Dosing Systems in the Hospital Consensus Guideline. J Diabetes Sci Technol 2020; 14:1035-1064. [PMID: 32985262 PMCID: PMC7645140 DOI: 10.1177/1932296820954163] [Citation(s) in RCA: 69] [Impact Index Per Article: 17.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
This article is the work product of the Continuous Glucose Monitor and Automated Insulin Dosing Systems in the Hospital Consensus Guideline Panel, which was organized by Diabetes Technology Society and met virtually on April 23, 2020. The guideline panel consisted of 24 international experts in the use of continuous glucose monitors (CGMs) and automated insulin dosing (AID) systems representing adult endocrinology, pediatric endocrinology, obstetrics and gynecology, advanced practice nursing, diabetes care and education, clinical chemistry, bioengineering, and product liability law. The panelists reviewed the medical literature pertaining to five topics: (1) continuation of home CGMs after hospitalization, (2) initiation of CGMs in the hospital, (3) continuation of AID systems in the hospital, (4) logistics and hands-on care of hospitalized patients using CGMs and AID systems, and (5) data management of CGMs and AID systems in the hospital. The panelists then developed three types of recommendations for each topic, including clinical practice (to use the technology optimally), research (to improve the safety and effectiveness of the technology), and hospital policies (to build an environment for facilitating use of these devices) for each of the five topics. The panelists voted on 78 proposed recommendations. Based on the panel vote, 77 recommendations were classified as either strong or mild. One recommendation failed to reach consensus. Additional research is needed on CGMs and AID systems in the hospital setting regarding device accuracy, practices for deployment, data management, and achievable outcomes. This guideline is intended to support these technologies for the management of hospitalized patients with diabetes.
Collapse
Affiliation(s)
| | | | | | - Ananda Basu
- University of Virginia School of Medicine, Charlottesville, VA, USA
| | - Suzanne Lohnes
- University of California San Diego Medical Center, La Jolla, CA, USA
| | | | - Elias K. Spanakis
- University of Maryland School of Medicine, Baltimore, MD, USA
- Division of Endocrinology, Baltimore Veterans Affairs Medical Center, MD, USA
| | | | - Nadine E. Palermo
- Brigham and Women’s Hospital, Harvard Medical School, Boston, MA, USA
| | | | | | | | | | | | | | | | | | - Tonya Newman
- Neal, Gerber and Eisenberg LLP, Chicago, IL, USA
| | - David N. O’Neal
- University of Melbourne Department of Medicine, St. Vincent’s Hospital, Fitzroy, Victoria, Australia
| | | | | | | | - Amisha Wallia
- Northwestern University Feinberg School of Medicine, Chicago, IL, USA
| | - Trisha Shang
- Diabetes Technology Society, Burlingame, CA, USA
| | | | - Julia Han
- Diabetes Technology Society, Burlingame, CA, USA
| | - David C. Klonoff
- Mills-Peninsula Medical Center, San Mateo, CA, USA
- David C. Klonoff, MD, FACP, FRCP (Edin), Fellow AIMBE, Mills-Peninsula Medical Center, 100 South San Mateo Drive Room 5147, San Mateo, CA 94401, USA.
| |
Collapse
|