Islam N, Suwandecha T, Srichana T. Dry powder inhaler design and particle technology in enhancing Pulmonary drug deposition: challenges and future strategies. Daru 2024:10.1007/s40199-024-00520-3. [PMID: 38861247 DOI: 10.1007/s40199-024-00520-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2023] [Accepted: 04/27/2024] [Indexed: 06/12/2024] Open
Abstract
OBJECTIVES The efficient delivery of drugs from dry powder inhaler (DPI) formulations is associated with the complex interaction between the device design, drug formulations, and patient's inspiratory forces. Several challenges such as limited emitted dose of drugs from the formulation, low and variable deposition of drugs into the deep lungs, are to be resolved for obtaining the efficiency in drug delivery from DPI formulations. The objective of this study is to review the current challenges of inhaled drug delivery technology and find a way to enhance the efficiency of drug delivery from DPIs. METHODS/EVIDENCE ACQUISITION Using appropriate keywords and phrases as search terms, evidence was collected from the published articles following SciFinder, Web of Science, PubMed and Google Scholar databases. RESULTS Successful lung drug delivery from DPIs is very challenging due to the complex anatomy of the lungs and requires an integrated strategy for particle technology, formulation design, device design, and patient inhalation force. New DPIs are still being developed with limited performance and future device design employs computer simulation and engineering technology to overcome the ongoing challenges. Many issues of drug formulation challenges and particle technology are concerning factors associated with drug dispersion from the DPIs into deep lungs. CONCLUSION This review article addressed the appropriate design of DPI devices and drug formulations aligned with the patient's inhalation maneuver for efficient delivery of drugs from DPI formulations.
Collapse
Affiliation(s)
- Nazrul Islam
- Pharmacy Discipline, School of Clinical Sciences, Faculty of Health, Queensland University of Technology, Brisbane, QLD, Australia.
- Centre for Immunology and Infection Control (CIIC), Queensland University of Technology, Brisbane, QLD, Australia.
| | - Tan Suwandecha
- Drug and Cosmetic Excellence Center and School of Pharmacy, Walailak University, Thasala, Nakhon Si Thammarat, 80160, Thailand
| | - Teerapol Srichana
- Drug Delivery System Excellence Center and Department of Pharmaceutical Technology, Prince of Songkla University, Hat Yai, Songkla, 90110, Thailand.
| |
Collapse
|
2
|
Ramachandran S, Prakash P, Mohtar N, Kumar KS, Parumasivam T. Review of inhalable nanoparticles for the pulmonary delivery of anti-tuberculosis drugs. Pharm Dev Technol 2023; 28:978-991. [PMID: 37937865 DOI: 10.1080/10837450.2023.2279691] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2022] [Accepted: 09/05/2023] [Indexed: 11/09/2023]
Abstract
Tuberculosis is an airborne disease caused by the pathogen, Mycobacterium tuberculosis, which predominantly affects the lungs. World Health Organization (WHO) has reported that about 85% of TB patients are cured with the existing 6-month antibiotic regimen. However, the lengthy oral administration of high-dose anti-TB drugs is associated with significant side effects and leads to drug resistance cases. Alternatively, reformulating existing anti-tubercular drugs into inhalable nanoparticulate systems is a promising strategy to overcome the challenges associated with oral treatment as they could enhance drug retention in the pulmonary region to achieve an optimal drug concentration in the infected lungs. Hence, this review provides an overview of the literature on inhalable nano-formulations for the delivery of anti-TB drugs, including their formulation techniques and preclinical evaluations between the years 2000 and 2020, gathered from electronic journals via online search engines such as Google Scholar and PubMed. Previous in vitro and in vivo studies highlighted that the nano-size, low toxicity, and high efficacy were among the factors influencing the fate of nanoparticulate system upon deposition in the lungs. Although many preclinical studies have shown that inhalable nanoparticles increased therapeutic efficacy and minimised adverse drug reactions when delivered through the pulmonary route, none of them has progressed into clinical trials to date. This could be attributed to the high cost of inhaled regimes due to the expensive production and characterisation of the nanoparticles as well as the need for an inhalation device as compared to the oral treatment. Another barrier could be the lack of medical acceptance due to insufficient number of trained staff to educate the patients on the correct usage of the inhalation device. Hence, these barriers should be addressed satisfactorily to make the inhaled nanoparticles regimen a reality for the treatment of TB.
Collapse
Affiliation(s)
- Sowmya Ramachandran
- School of Pharmaceutical Sciences, Universiti Sains Malaysia, Minden, Pulau Pinang, Malaysia
| | - Priyanka Prakash
- School of Pharmaceutical Sciences, Universiti Sains Malaysia, Minden, Pulau Pinang, Malaysia
| | - Noratiqah Mohtar
- School of Pharmaceutical Sciences, Universiti Sains Malaysia, Minden, Pulau Pinang, Malaysia
| | - K Sudesh Kumar
- School of Biological Sciences, Universiti Sains Malaysia, Minden, Pulau Pinang, Malaysia
| | - Thaigarajan Parumasivam
- School of Pharmaceutical Sciences, Universiti Sains Malaysia, Minden, Pulau Pinang, Malaysia
| |
Collapse
|
3
|
Zhang L, Li S, Yuan S, Lu X, Li J, Liu Y, Huang T, Lyu J, Yin H. The Association Between Bronchoscopy and the Prognoses of Patients With Ventilator-Associated Pneumonia in Intensive Care Units: A Retrospective Study Based on the MIMIC-IV Database. Front Pharmacol 2022; 13:868920. [PMID: 35754471 PMCID: PMC9214225 DOI: 10.3389/fphar.2022.868920] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2022] [Accepted: 05/06/2022] [Indexed: 11/13/2022] Open
Abstract
Background: In intensive care units (ICUs), the morbidity and mortality of ventilator-associated pneumonia (VAP) are relatively high, and this condition also increases medical expenses for mechanically ventilated patients, which will seriously affect the prognoses of critically ill patients. The purpose of this study was to determine the impact of bronchoscopy on the prognosis of patients with VAP undergoing invasive mechanical ventilation (IMV). Methods: This was a retrospective study based on patients with VAP from the Medical Information Mart for Intensive Care IV database. The outcomes were ICU and in-hospital mortality. Patients were divided based on whether or not they had undergone bronchoscopy during IMV. Kaplan-Meier (KM) survival curves and Cox proportional-hazards regression models were used to analyze the association between groups and outcomes. Propensity score matching (PSM) and propensity score based inverse probability of treatment weighting (IPTW) were used to further verify the stability of the results. The effect of bronchoscopy on prognosis was further analyzed by causal mediation analysis (CMA). Results: This study enrolled 1,560 patients with VAP: 1,355 in the no-bronchoscopy group and 205 in the bronchoscopy group. The KM survival curve indicated a significant difference in survival probability between the two groups. The survival probabilities in both the ICU and hospital were significantly higher in the bronchoscopy group than in the no bronchoscopy group. After adjusting all covariates as confounding factors in the Cox model, the HRs (95% CI) for ICU and in-hospital mortality in the bronchoscopy group were 0.33 (0.20–0.55) and 0.40 (0.26–0.60), respectively, indicating that the risks of ICU and in-hospital mortality were 0.67 and 0.60 lower than in the no-bronchoscopy group. The same trend was obtained after using PSM and IPTW. CMA showed that delta-red blood cell distribution width (RDW) mediated 8 and 7% of the beneficial effects of bronchoscopy in ICU mortality and in-hospital mortality. Conclusion: Bronchoscopy during IMV was associated with reducing the risk of ICU and in-hospital mortality in patients with VAP in ICUs, and this beneficial effect was partially mediated by changes in RDW levels.
Collapse
Affiliation(s)
- Luming Zhang
- Department of Intensive Care Unit, The First Affiliated Hospital of Jinan University, Guangzhou, China.,Department of Clinical Research, The First Affiliated Hospital of Jinan University, Guangzhou, China
| | - Shaojin Li
- Department of Intensive Care Unit, The First Affiliated Hospital of Jinan University, Guangzhou, China.,Department of Clinical Research, The First Affiliated Hospital of Jinan University, Guangzhou, China.,Department of Orthopaedics, The First Affiliated Hospital of Jinan University, Guangzhou, China.,Department of Neurology, The First Affiliated Hospital of Jinan University, Guangzhou, China.,Guangdong Provincial Key Laboratory of Traditional Chinese Medicine Informatization, Guangzhou, China
| | - Shiqi Yuan
- Department of Intensive Care Unit, The First Affiliated Hospital of Jinan University, Guangzhou, China.,Department of Clinical Research, The First Affiliated Hospital of Jinan University, Guangzhou, China.,Department of Orthopaedics, The First Affiliated Hospital of Jinan University, Guangzhou, China.,Department of Neurology, The First Affiliated Hospital of Jinan University, Guangzhou, China.,Guangdong Provincial Key Laboratory of Traditional Chinese Medicine Informatization, Guangzhou, China
| | - Xuehao Lu
- Department of Intensive Care Unit, The First Affiliated Hospital of Jinan University, Guangzhou, China.,Department of Clinical Research, The First Affiliated Hospital of Jinan University, Guangzhou, China
| | - Jieyao Li
- Department of Intensive Care Unit, The First Affiliated Hospital of Jinan University, Guangzhou, China
| | - Yu Liu
- Department of Intensive Care Unit, The First Affiliated Hospital of Jinan University, Guangzhou, China
| | - Tao Huang
- Department of Clinical Research, The First Affiliated Hospital of Jinan University, Guangzhou, China
| | - Jun Lyu
- Department of Clinical Research, The First Affiliated Hospital of Jinan University, Guangzhou, China.,Guangdong Provincial Key Laboratory of Traditional Chinese Medicine Informatization, Guangzhou, China
| | - Haiyan Yin
- Department of Intensive Care Unit, The First Affiliated Hospital of Jinan University, Guangzhou, China
| |
Collapse
|
4
|
|
5
|
Ke WR, Chang RYK, Kwok PCL, Tang P, Chen L, Chen D, Chan HK. Administration of dry powders during respiratory supports. ANNALS OF TRANSLATIONAL MEDICINE 2021; 9:596. [PMID: 33987294 DOI: 10.21037/atm-20-3946] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Inhaled drugs are routinely used for the treatment of respiratory-supported patients. To date, pressurized metered dose inhalers and nebulizers are the two platforms routinely employed in the clinical setting. The scarce utilization of the dry powder inhaler (DPI) platform is partly due to the lack of in vivo data that proves optimal delivery and drug efficacy are achievable. Additionally, fitting a DPI in-line to the respiratory circuit is not as straightforward as with the other aerosol delivery platforms. Importantly, there is a common misconception that the warm and humidified inspiratory air in respiratory supports, even for a short exposure, will deteriorate powder formulation compromising its delivery and efficacy. However, some recent studies have dispelled this myth, showing successful delivery of dry powders through the humidified circuit of respiratory supports. Compared with other aerosol delivery devices, the use of DPIs during respiratory supports possesses unique advantages such as rapid delivery and high dose. In this review, we presented in vitro studies showing various setups employing commercial DPIs and effects of ventilator parameters on the aerosol delivery. Inclusion of novel DPIs was also made to illustrate characteristics of an ideal inhaler that would give high lung dose with low powder deposition loss in tracheal tubes and respiratory circuits. Clinical trials are urgently needed to confirm the benefits of administration of dry powders in ventilated patients, thus enabling translation of powder delivery into practice.
Collapse
Affiliation(s)
- Wei-Ren Ke
- Advanced Drug Delivery Group, School of Pharmacy, Faculty of Medicine and Health, University of Sydney, Sydney, New South Wales, Australia
| | - Rachel Yoon Kyung Chang
- Advanced Drug Delivery Group, School of Pharmacy, Faculty of Medicine and Health, University of Sydney, Sydney, New South Wales, Australia
| | - Philip Chi Lip Kwok
- Advanced Drug Delivery Group, School of Pharmacy, Faculty of Medicine and Health, University of Sydney, Sydney, New South Wales, Australia
| | - Patricia Tang
- Advanced Drug Delivery Group, School of Pharmacy, Faculty of Medicine and Health, University of Sydney, Sydney, New South Wales, Australia
| | - Lan Chen
- Hangzhou Chance Pharmaceuticals, Hangzhou, China
| | - Donghao Chen
- Hangzhou Chance Pharmaceuticals, Hangzhou, China
| | - Hak-Kim Chan
- Advanced Drug Delivery Group, School of Pharmacy, Faculty of Medicine and Health, University of Sydney, Sydney, New South Wales, Australia
| |
Collapse
|
6
|
Lin HL, Fink JB, Ge H. Aerosol delivery via invasive ventilation: a narrative review. ANNALS OF TRANSLATIONAL MEDICINE 2021; 9:588. [PMID: 33987286 DOI: 10.21037/atm-20-5665] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
In comparison with spontaneously breathing non-intubated subjects, intubated, mechanically ventilated patients encounter various challenges, barriers, and opportunities in receiving medical aerosols. Since the introduction of mechanical ventilation as a part of modern critical care medicine during the middle of the last century, aerosolized drug delivery by jet nebulizers has become a common practice. However, early evidence suggested that aerosol generators differed in their efficacies, and the introduction of newer aerosol technology (metered dose inhalers, ultrasonic nebulizer, vibrating mesh nebulizers, and soft moist inhaler) into the ventilator circuit opened up the possibility of optimizing inhaled aerosol delivery during mechanical ventilation that could meet or exceed the delivery of the same aerosols in spontaneously breathing patients. This narrative review will catalogue the primary variables associated with this process and provide evidence to guide optimal aerosol delivery and dosing during mechanical ventilation. While gaps exist in relation to the appropriate aerosol drug dose, discrepancies in practice, and cost-effectiveness of the administered aerosol drugs, we also present areas for future research and practice. Clinical practice should expand to incorporate these techniques to improve the consistency of drug delivery and provide safer and more effective care for patients.
Collapse
Affiliation(s)
- Hui-Ling Lin
- Department of Respiratory Therapy, Chang Gung University, Taoyuan.,Department of Respiratory Care, Chang Gung University of Science and Technology, Chiayi.,Department of Respiratory Therapy, Chiayi Chang Gung Memorial Hospital, Chiayi
| | - James B Fink
- Division of Respiratory Care, Rush University Medical Center, Chicago, IL, USA.,Aerogen Pharma Corp., San Mateo, California, USA
| | - Huiqing Ge
- Department of Respiratory Care, Sir Run Run Shaw Hospital, School of Medicine, Zhejiang University, Hangzhou, China
| |
Collapse
|
7
|
Farkas D, Hindle M, Bonasera S, Bass K, Longest W. Development of an Inline Dry Powder Inhaler for Oral or Trans-Nasal Aerosol Administration to Children. J Aerosol Med Pulm Drug Deliv 2019; 33:83-98. [PMID: 31464559 DOI: 10.1089/jamp.2019.1540] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023] Open
Abstract
Background: Dry powder inhalers (DPIs) offer a number of advantages, such as rapid delivery of high-dose inhaled medications; however, DPI use in children is often avoided due to low lung delivery efficiency and difficulty in operating the device. The objective of this study was to develop a high-efficiency inline DPI for administering aerosol therapy to children with the option of using either an oral or trans-nasal approach. Methods: An inline DPI was developed that consisted of hollow inlet and outlet capillaries, a powder chamber, and a nasal or oral interface. A ventilation bag or compressed air was used to actuate the device and simultaneously provide a full deep inspiration consistent with a 5-year-old child. The powder chamber was partially filled with a model spray-dried excipient enhanced growth powder formulation with a mass of 10 mg. Device aerosolization was characterized with cascade impaction, and aerosol transmissions through oral and nasal in vitro models were assessed. Results: Best device performance was achieved when all actuation air passed through the powder chamber (no bypass flow) resulting in an aerosol mean mass median aerodynamic diameter (MMAD) <1.75 μm and a fine particle fraction (<5 μm) ≥90% based on emitted dose. Actuation with the ventilation bag enabled lung delivery efficiency through the nasal and oral interfaces to a tracheal filter of 60% or greater, based on loaded dose. In both oral and nose-to-lung (N2L) administrations, extrathoracic depositional losses were <10%. Conclusion: In conclusion, this study has proposed and initially developed an efficient inline DPI for delivering spray-dried formulations to children using positive pressure operation. Actuation of the device with positive pressure enabled effective N2L aerosol administration with a DPI, which may be beneficial for subjects who are too young to use a mouthpiece or to simultaneously treat the nasal and lung airways of older children.
Collapse
Affiliation(s)
- Dale Farkas
- Department of Mechanical and Nuclear Engineering and Virginia Commonwealth University, Richmond, Virginia
| | - Michael Hindle
- Department of Pharmaceutics, Virginia Commonwealth University, Richmond, Virginia
| | - Serena Bonasera
- Department of Pharmaceutics, Virginia Commonwealth University, Richmond, Virginia
| | - Karl Bass
- Department of Mechanical and Nuclear Engineering and Virginia Commonwealth University, Richmond, Virginia
| | - Worth Longest
- Department of Mechanical and Nuclear Engineering and Virginia Commonwealth University, Richmond, Virginia.,Department of Pharmaceutics, Virginia Commonwealth University, Richmond, Virginia
| |
Collapse
|
8
|
Farkas D, Hindle M, Longest PW. Efficient Nose-to-Lung Aerosol Delivery with an Inline DPI Requiring Low Actuation Air Volume. Pharm Res 2018; 35:194. [PMID: 30132207 DOI: 10.1007/s11095-018-2473-7] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2018] [Accepted: 08/03/2018] [Indexed: 11/28/2022]
Abstract
PURPOSE To demonstrate efficient aerosol delivery through an in vitro nasal model using a dry powder inhaler (DPI) requiring low actuation air volumes (LV) applied during low-flow nasal cannula (LFNC) therapy. METHODS A previously developed LV-DPI was connected to a LFNC system with 4 mm diameter tubing. System connections and the nasal cannula interface were replaced with streamlined components. To simulate nasal respiration, an in vitro nasal model was connected to a downstream lung simulator that produced either passive or deep nasal respiration. Performance of a commercial mesh nebulizer system was also considered. RESULTS For the optimized system, steady state cannula emitted dose was 75% of the capsule loaded dose. With cyclic nasal breathing, delivery efficiency to the tracheal filter was 53-55% of the loaded dose, which was just under the design target of 60%. Compared with a commercially available mesh nebulizer, the optimal LV-DPI was 40-fold more efficient and 150 times faster in terms of delivering aerosol to the lungs. CONCLUSIONS The optimized LV-DPI system is capable of high efficiency lung delivery of powder aerosols through a challenging nasal cannula interface.
Collapse
Affiliation(s)
- Dale Farkas
- Department of Mechanical and Nuclear Engineering, Virginia Commonwealth University, 401 West Main Street, P.O. Box 843015 Richmond, Virginia, 23284-3015, USA
| | - Michael Hindle
- Department of Pharmaceutics, Virginia Commonwealth University Richmond, Virginia, USA
| | - P Worth Longest
- Department of Mechanical and Nuclear Engineering, Virginia Commonwealth University, 401 West Main Street, P.O. Box 843015 Richmond, Virginia, 23284-3015, USA. .,Department of Pharmaceutics, Virginia Commonwealth University Richmond, Virginia, USA.
| |
Collapse
|
9
|
Application of an inline dry powder inhaler to deliver high dose pharmaceutical aerosols during low flow nasal cannula therapy. Int J Pharm 2018; 546:1-9. [PMID: 29733972 DOI: 10.1016/j.ijpharm.2018.05.011] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2018] [Revised: 04/30/2018] [Accepted: 05/04/2018] [Indexed: 11/21/2022]
Abstract
Inline dry powder inhalers (DPIs) offer a potentially effective option to deliver high dose inhaled medications simultaneously with mechanical ventilation. The objective of this study was to develop an inline DPI that is actuated using a low volume of air (LV-DPI) to efficiently deliver pharmaceutical aerosols during low flow nasal cannula (LFNC) therapy. A characteristic feature of the new inline LV-DPIs was the use of hollow capillary tubes that both pierced the capsule and provided a pathway for inlet air and exiting aerosol. Aerosolization characteristics, LFNC depositional losses and emitted dose (ED) were determined using 10 mg powder masses of a small-particle excipient enhanced growth (EEG) formulation. While increasing the number of inlet capillaries from one to three did not improve performance, retracting the inlet and outlet capillaries did improve ED by over 30%. It was theorized that high quality performance requires both high turbulent energy to deaggregate the powder and high wall shear stresses to minimize capsule retention. Best case performance included a device ED of approximately 85% (of loaded dose) and device emitted mass median aerodynamic diameter of 1.77 µm. Maximum ED through the LFNC system and small diameter (4 mm) nasal cannula was approximately 65% of the loaded dose. Potential applications of this device include the delivery of high dose inhaled medications such as surfactants, antibiotics, mucolytics, and anti-inflammatories.
Collapse
|
10
|
Farkas D, Hindle M, Longest PW. Development of an Inline Dry Powder Inhaler That Requires Low Air Volume. J Aerosol Med Pulm Drug Deliv 2017; 31:255-265. [PMID: 29261454 DOI: 10.1089/jamp.2017.1424] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
BACKGROUND Inline dry powder inhalers (DPIs) are actuated by an external air source and have distinct advantages for delivering aerosols to infants and children, and to individuals with compromised lung function or who require ventilator support. However, current inline DPIs either perform poorly, are difficult to operate, and/or require large volumes (∼1 L) of air. The objective of this study was to develop and characterize a new inline DPI for aerosolizing spray-dried formulations with powder masses of 10 mg and higher using a dispersion air volume of 10 mL per actuation that is easy to load (capsule-based) and operate. METHODS Primary features of the new low air volume (LV) DPIs are fixed hollow capillaries that both pierce the capsule and provide a continuous flow path for air and aerosol passing through the device. Two different configurations were evaluated, which were a straight-through (ST) device, with the inlet and outlet capillaries on opposite ends of the capsule, and a single-sided (SS) device, with both the inlet and outlet capillaries on the same side of the capsule. The devices were operated with five actuations of a 10 mL air syringe using an albuterol sulfate (AS) excipient-enhanced growth (EEG) formulation. Device emptying and aerosol characteristics were evaluated for multiple device outlet configurations. RESULTS Each device had specific advantages. The best case ST device produced the smallest aerosol [mean mass median aerodynamic diameter (MMAD) = 1.57 μm; fine particle fraction <5 μm (FPF<5μm) = 95.2%)] but the mean emitted dose (ED) was 61.9%. The best case SS device improved ED (84.8%), but produced a larger aerosol (MMAD = 2.13 μm; FPF<5μm = 89.3%) that was marginally higher than the initial deaggregation target. CONCLUSIONS The new LV-DPIs produced an acceptable high-quality aerosol with only 10 mL of dispersion air per actuation and were easy to load and operate. This performance should enable application in high and low flow mechanical ventilation systems and high efficiency lung delivery to both infants and children.
Collapse
Affiliation(s)
- Dale Farkas
- 1 Department of Mechanical and Nuclear Engineering, Virginia Commonwealth University , Richmond, Virginia
| | - Michael Hindle
- 2 Department of Pharmaceutics, Virginia Commonwealth University , Richmond, Virginia
| | - P Worth Longest
- 1 Department of Mechanical and Nuclear Engineering, Virginia Commonwealth University , Richmond, Virginia.,2 Department of Pharmaceutics, Virginia Commonwealth University , Richmond, Virginia
| |
Collapse
|
11
|
Ari A, Fink JB. Inhalation therapy in patients with tracheostomy: a guide to clinicians. Expert Rev Respir Med 2017; 11:201-208. [PMID: 28228052 DOI: 10.1080/17476348.2017.1289843] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
INTRODUCTION Inhalation therapy has become a popular procedure for the treatment of patients with tracheostomy. However, clinicians are faced with many challenges during inhalation therapy because of the many factors affecting aerosol therapy to this patient population, and the lack of literature providing guidance in this area of research. Areas covered: The purpose of this paper is to describe the factors affecting aerosol drug delivery to patients with tracheostomy and to explain how to optimize inhalation therapy through device selection, interface selection and delivery technique in this patient population. Expert commentary: Many factors affect inhalation therapy in this patient population and without understanding the impact of these factors on aerosol drug delivery, clinicians will not be able to provide the treatment properly and patients may not benefit from prescribed medications. In the next 5 years, aerosol medicine will continue to experience tremendous growth with new devices and drug/device combinations. However, these advances will have minimal impact on inhalation therapy in patients with tracheostomy unless we provide guidance and training to clinicians on optimizing aerosol drug delivery to this patient population.
Collapse
Affiliation(s)
- Arzu Ari
- a Department of Respiratory Therapy , Georgia State University , Atlanta , GA , USA
| | - James B Fink
- a Department of Respiratory Therapy , Georgia State University , Atlanta , GA , USA
| |
Collapse
|
12
|
Walenga RL, Longest PW, Kaviratna A, Hindle M. Aerosol Drug Delivery During Noninvasive Positive Pressure Ventilation: Effects of Intersubject Variability and Excipient Enhanced Growth. J Aerosol Med Pulm Drug Deliv 2017; 30:190-205. [PMID: 28075194 DOI: 10.1089/jamp.2016.1343] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023] Open
Abstract
BACKGROUND Nebulized aerosol drug delivery during the administration of noninvasive positive pressure ventilation (NPPV) is commonly implemented. While studies have shown improved patient outcomes for this therapeutic approach, aerosol delivery efficiency is reported to be low with high variability in lung-deposited dose. Excipient enhanced growth (EEG) aerosol delivery is a newly proposed technique that may improve drug delivery efficiency and reduce intersubject aerosol delivery variability when coupled with NPPV. MATERIALS AND METHODS A combined approach using in vitro experiments and computational fluid dynamics (CFD) was used to characterize aerosol delivery efficiency during NPPV in two new nasal cavity models that include face mask interfaces. Mesh nebulizer and in-line dry powder inhaler (DPI) sources of conventional and EEG aerosols were both considered. RESULTS Based on validated steady-state CFD predictions, EEG aerosol delivery improved lung penetration fraction (PF) values by factors ranging from 1.3 to 6.4 compared with conventional-sized aerosols. Furthermore, intersubject variability in lung PF was very high for conventional aerosol sizes (relative differences between subjects in the range of 54.5%-134.3%) and was reduced by an order of magnitude with the EEG approach (relative differences between subjects in the range of 5.5%-17.4%). Realistic in vitro experiments of cyclic NPPV demonstrated similar trends in lung delivery to those observed with the steady-state simulations, but with lower lung delivery efficiencies. Reaching the lung delivery efficiencies reported with the steady-state simulations of 80%-90% will require synchronization of aerosol administration during inspiration and reducing the size of the EEG aerosol delivery unit. CONCLUSIONS The EEG approach enabled high-efficiency lung delivery of aerosols administered during NPPV and reduced intersubject aerosol delivery variability by an order of magnitude. Use of an in-line DPI device that connects to the NPPV mask appears to be a convenient method to rapidly administer an EEG aerosol and synchronize the delivery with inspiration.
Collapse
Affiliation(s)
- Ross L Walenga
- 1 Department of Mechanical and Nuclear Engineering, Virginia Commonwealth University , Richmond, Virginia
| | - P Worth Longest
- 1 Department of Mechanical and Nuclear Engineering, Virginia Commonwealth University , Richmond, Virginia.,2 Department of Pharmaceutics, Virginia Commonwealth University , Richmond, Virginia
| | - Anubhav Kaviratna
- 2 Department of Pharmaceutics, Virginia Commonwealth University , Richmond, Virginia
| | - Michael Hindle
- 2 Department of Pharmaceutics, Virginia Commonwealth University , Richmond, Virginia
| |
Collapse
|
13
|
Yang MY, Chan HK. Monitoring the Inhalation Flow Rate of Nebulized Aerosols Using an Ultrasonic Flow Meter: In Vitro Assessment. J Aerosol Med Pulm Drug Deliv 2016; 30:173-181. [PMID: 27849432 DOI: 10.1089/jamp.2016.1346] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022] Open
Abstract
BACKGROUND The measurement of aerosol flow rates without obscuration of the flow is of particular concern with in vivo lung deposition studies, where precise knowledge of aerosol particle size distributions is a necessary requirement for the development of predictive correlations. This study examines the utility of an ultrasonic flow meter for such measurements and determines if a valved system can be attached to the flow meter for sampling exhaled aerosols. METHODS The flow rate across a D-30 flow meter was compared with and without nebulization of 0.9% saline aerosols from a PARI LC Sprint nebulizer. Particle size distributions of the nebulized aerosol before and after adding the D-30 flow meter and duckbill valve were measured using a Spraytec laser diffraction system. Finally, the ability of the Thor D-30 to capture a realistic breathing profile was assessed. RESULTS The mean ± standard error flow rates measured by the D-30 flow meter with and without nebulization were 10.4 ± 0.1 versus 10.4 ± 0.1 L/min, 66.4 ± 0.1 versus 67.2 ± 0.1 L/min, and 89.9 ± 0.1 versus 91.4 ± 0.1 L/min. The D-30 flow meter did not considerably affect the volumetric median diameter (VMD) of the aerosols, while the VMD reduced slightly by 0.65 μm at 10 L/min and 0.69 μm at 72 L/min upon the inclusion of a duckbill valve. Time-weighted average inhalation flow rates measured by D-30 flow meters placed upstream and downstream of the one-way valve agreed well, 31.9 versus 32.6 L/min, respectively. CONCLUSIONS The D-30 flow meter can be used to accurately measure inhalation flow rates of nebulized aerosols without significantly impacting particle size distributions, and one-way duckbill valves can be used to isolate the inhalation portion of a breathing pattern to facilitate collection of exhaled doses.
Collapse
Affiliation(s)
- Michael Y Yang
- Advanced Drug Delivery Group, Faculty of Pharmacy, University of Sydney , Sydney, Australia
| | - Hak-Kim Chan
- Advanced Drug Delivery Group, Faculty of Pharmacy, University of Sydney , Sydney, Australia
| |
Collapse
|
14
|
Feng B, Tang P, Leung SSY, Dhanani J, Chan HK. A Novel In-Line Delivery System to Administer Dry Powder Mannitol to Mechanically Ventilated Patients. J Aerosol Med Pulm Drug Deliv 2016; 30:100-107. [PMID: 27754730 DOI: 10.1089/jamp.2016.1320] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
BACKGROUND Mechanically ventilated patients commonly suffer from ventilator-associated pneumonia, hypoxemia, and other lower respiratory tract infection as a result of pathogen colonization and poor sputum clearance. Consequently, there is a high rate of morbidity and mortality in these patients. Dry powder mannitol increases sputum clearance, and therefore, we developed a system to administer it to mechanically ventilated patients without disconnection from the ventilator. METHODS The inspiratory line from a ventilator was split by using a three-way valve into two parallel lines where one contains a humidifier for normal breathing cycle and the other line contains a dry powder inhaler (Osmohaler™). The inspiratory air went through the dry powder line and aerosolized the mannitol powder only when its administration to a patient is required. We determined the delivered dose and particle size distributions of emitted aerosols in vitro from 9.5 mm endotracheal and 7.5 mm tracheostomy tubes, with inspiratory airflow of 60, 70, and 80 L/min. RESULTS This novel setup was able to deliver 24.6% ± 3.33% of the 160 mg loaded dose mannitol powder (4 × 40 mg capsules) and 26.7% ± 2.19% of the 320 mg dose (4 × 80 mg capsules) when the endotracheal tube was used. With the shorter tracheostomy tube, the delivery dose increased to 35.6% ± 3.01% and 39.5% ± 2.04% of the 160 and 320 mg doses, respectively. The volume median diameters of the aerosols were in the respirable range with the largest value being 5.17 ± 0.87 μm. CONCLUSIONS This delivery system has been shown to consistently deliver a high respirable dose of mannitol powder. Since this setup does not require disconnection of patients from the ventilator, it is safer for hypoxemic patients and easier to be adapted in a real clinical use.
Collapse
Affiliation(s)
- Benny Feng
- 1 Advanced Drug Delivery Group, Faculty of Pharmacy, The University of Sydney , Sydney, Australia
| | - Patricia Tang
- 1 Advanced Drug Delivery Group, Faculty of Pharmacy, The University of Sydney , Sydney, Australia
| | - Sharon Shui Yee Leung
- 1 Advanced Drug Delivery Group, Faculty of Pharmacy, The University of Sydney , Sydney, Australia
| | - Jayesh Dhanani
- 2 Department of Intensive Care, Royal Brisbane Women's Hospital , Herston, Australia .,3 Burns, Trauma and Critical Care Research Centre, University of Queensland , Queensland, Australia
| | - Hak-Kim Chan
- 1 Advanced Drug Delivery Group, Faculty of Pharmacy, The University of Sydney , Sydney, Australia
| |
Collapse
|
15
|
Parumasivam T, Chang RYK, Abdelghany S, Ye TT, Britton WJ, Chan HK. Dry powder inhalable formulations for anti-tubercular therapy. Adv Drug Deliv Rev 2016; 102:83-101. [PMID: 27212477 DOI: 10.1016/j.addr.2016.05.011] [Citation(s) in RCA: 54] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2015] [Revised: 05/13/2016] [Accepted: 05/14/2016] [Indexed: 12/31/2022]
Abstract
Tuberculosis (TB) is an intracellular infectious disease caused by the airborne bacterium, Mycobacterium tuberculosis. Despite considerable research efforts, the treatment of TB continues to be a great challenge in part due to the requirement of prolonged therapy with multiple high-dose drugs and associated side effects. The delivery of pharmacological agents directly to the respiratory system, following the natural route of infection, represents a logical therapeutic approach for treatment or vaccination against TB. Pulmonary delivery is non-invasive, avoids first-pass metabolism in the liver and enables targeting of therapeutic agents to the infection site. Inhaled delivery also potentially reduces the dose requirement and the accompanying side effects. Dry powder is a stable formulation of drug that can be stored without refrigeration compared to liquids and suspensions. The dry powder inhalers are easy to use and suitable for high-dose formulations. This review focuses on the current innovations of inhalable dry powder formulations of drug and vaccine delivery for TB, including the powder production method, preclinical and clinical evaluations of inhaled dry powder over the last decade. Finally, the risks associated with pulmonary therapy are addressed. A novel dry powder formulation with high percentages of respirable particles coupled with a cost effective inhaler device is an appealing platform for TB drug delivery.
Collapse
Affiliation(s)
- Thaigarajan Parumasivam
- Advanced Drug Delivery Group, Faculty of Pharmacy, The University of Sydney, NSW 2006, Australia
| | - Rachel Yoon Kyung Chang
- Advanced Drug Delivery Group, Faculty of Pharmacy, The University of Sydney, NSW 2006, Australia
| | - Sharif Abdelghany
- Department of Pharmaceutics and Pharmaceutical Technology, Faculty of Pharmacy, University of Jordan, Amman 1192, Jordan
| | - Tian Tian Ye
- Advanced Drug Delivery Group, Faculty of Pharmacy, The University of Sydney, NSW 2006, Australia
| | - Warwick John Britton
- Tuberculosis Research Program, Centenary Institute, The University of Sydney, NSW 2006, Australia; Infectious Diseases and Immunology, Sydney Medical School, The University of Sydney, NSW 2006, Australia
| | - Hak-Kim Chan
- Advanced Drug Delivery Group, Faculty of Pharmacy, The University of Sydney, NSW 2006, Australia.
| |
Collapse
|
16
|
Leung SSY, Parumasivam T, Tang P, Chan HK. A Proof-of-Principle Setup for Delivery of Relenza ® (Zanamivir) Inhalation Powder to Intubated Patients. J Aerosol Med Pulm Drug Deliv 2015; 29:30-35. [PMID: 25974393 DOI: 10.1089/jamp.2014.1179] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022] Open
Abstract
BACKGROUND A fatal incident was reported when a mechanical ventilated patient received nebulization of a reconstituted Relenza® formulation. We propose a delivery system to introduce Relenza and other inhalation dry powders to intubated patients to avoid accidental fatalities in the future. METHODS This is a bench study demonstrating the feasibility of a delivery system to introduce dry powder of Relenza to intubated patients. A dry powder inhaler placed within a delivery chamber was actuated by compressing a ventilation bag to disperse powder into a tracheal tube. The performance of two inhalers, a Diskhaler® and an Osmohaler™, were compared. The effects of the length and size of the tracheal tube on the powder output and sizing of emitted powder were investigated using the more efficient Osmohaler™. RESULTS The efficiency of Osmohaler in delivering Relenza to the distal end [delivered dose=30.2±0.2% and fine particle fraction (FPF)=14.5±1.7%] was significantly higher than the Diskhaler (delivered dose=18.1±4.7% and FPF=3.4±2.1%). While no differences in the delivered dose and FPF were observed between the tracheostomy and endotracheal tubes of the same internal diameter, a larger endotracheal tube (9.0 mm internal diameter) gave a 6% higher FPF compared with the smaller counterpart (7.0 mm internal diameter). CONCLUSION The dry powder delivery system has been demonstrated to be capable of delivering Relenza formulation to the distal end of tracheal tubes with a reasonable delivered dose and FPF. It would be necessary for further investigation into incorporating the proposed powder delivery system within a mechanical ventilator, as well as animal and clinical studies to prove its applicability to deliver zanamivir dry powder to ventilated influenza patients in the intensive care setting.
Collapse
Affiliation(s)
| | | | - Patricia Tang
- Faculty of Pharmacy, The University of Sydney , Sydney, NSW, Australia
| | - Hak-Kim Chan
- Faculty of Pharmacy, The University of Sydney , Sydney, NSW, Australia
| |
Collapse
|
17
|
Velkov T, Abdul Rahim N, Zhou Q(T, Chan HK, Li J. Inhaled anti-infective chemotherapy for respiratory tract infections: successes, challenges and the road ahead. Adv Drug Deliv Rev 2015; 85:65-82. [PMID: 25446140 PMCID: PMC4429008 DOI: 10.1016/j.addr.2014.11.004] [Citation(s) in RCA: 63] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2014] [Revised: 11/04/2014] [Accepted: 11/05/2014] [Indexed: 12/31/2022]
Abstract
One of the most common causes of illnesses in humans is from respiratory tract infections caused by bacterial, viral or fungal pathogens. Inhaled anti-infective drugs are crucial for the prophylaxis and treatment of respiratory tract infections. The benefit of anti-infective drug delivery via inhalation is that it affords delivery of sufficient therapeutic dosages directly to the primary site of infection, while minimizing the risks of systemic toxicity or avoiding potential suboptimal pharmacokinetics/pharmacodynamics associated with systemic drug exposure. This review provides an up-to-date treatise of approved and novel developmental inhaled anti-infective agents, with particular attention to effective strategies for their use, pulmonary pharmacokinetic properties and safety.
Collapse
|
18
|
Zhou Q(T, Tang P, Leung SSY, Chan JGY, Chan HK. Emerging inhalation aerosol devices and strategies: where are we headed? Adv Drug Deliv Rev 2014; 75:3-17. [PMID: 24732364 DOI: 10.1016/j.addr.2014.03.006] [Citation(s) in RCA: 127] [Impact Index Per Article: 12.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2014] [Revised: 03/23/2014] [Accepted: 03/24/2014] [Indexed: 02/07/2023]
Abstract
Novel inhaled therapeutics including antibiotics, vaccines and anti-hypertensives, have led to innovations in designing suitable delivery systems. These emerging design technologies are in urgent demand to ensure high aerosolisation performance, consistent efficacy and satisfactory patient adherence. Recent vibrating-mesh and software technologies have resulted in nebulisers that have remarkably accurate dosing and portability. Alternatively, dry powder inhalers (DPIs) have become highly favourable for delivering high-dose and single-dose drugs with the aid of advanced particle engineering. In contrast, innovations are needed to overcome the technical constrains in drug-propellant incompatibility and delivering high-dose drugs with pressurised metered dose inhalers (pMDIs). This review discusses recent and emerging trends in pulmonary drug delivery systems.
Collapse
|
19
|
Behara SRB, Longest PW, Farkas DR, Hindle M. Development of high efficiency ventilation bag actuated dry powder inhalers. Int J Pharm 2014; 465:52-62. [PMID: 24508552 PMCID: PMC4051231 DOI: 10.1016/j.ijpharm.2014.01.043] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2013] [Accepted: 01/30/2014] [Indexed: 01/19/2023]
Abstract
New active dry powder inhaler systems were developed and tested to efficiently aerosolize a carrier-free formulation. To assess inhaler performance, a challenging case study of aerosol lung delivery during high-flow nasal cannula (HFNC) therapy was selected. The active delivery system consisted of a ventilation bag for actuating the device, the DPI containing a flow control orifice and 3D rod array, and streamlined nasal cannula with separate inlets for the aerosol and HFNC therapy gas. In vitro experiments were conducted to assess deposition in the device, emitted dose (ED) from the nasal cannula, and powder deaggregation. The best performing systems achieved EDs of 70-80% with fine particle fractions <5 μm of 65-85% and mass median aerodynamic diameters of 1.5 μm, which were target conditions for controlled condensational growth aerosol delivery. Decreasing the size of the flow control orifice from 3.6 to 2.3mm reduced the flow rate through the system with manual bag actuations from an average of 35 to 15LPM, while improving ED and aerosolization performance. The new devices can be applied to improve aerosol delivery during mechanical ventilation, nose-to-lung aerosol administration, and to assist patients that cannot reproducibly use passive DPIs.
Collapse
Affiliation(s)
- Srinivas R B Behara
- Department of Mechanical and Nuclear Engineering, Virginia Commonwealth University, Richmond, VA, United States; Department of Pharmaceutics, Virginia Commonwealth University, Richmond, VA, United States
| | - P Worth Longest
- Department of Mechanical and Nuclear Engineering, Virginia Commonwealth University, Richmond, VA, United States; Department of Pharmaceutics, Virginia Commonwealth University, Richmond, VA, United States.
| | - Dale R Farkas
- Department of Mechanical and Nuclear Engineering, Virginia Commonwealth University, Richmond, VA, United States
| | - Michael Hindle
- Department of Pharmaceutics, Virginia Commonwealth University, Richmond, VA, United States
| |
Collapse
|
20
|
|
21
|
An In vitro Study on the Deposition of Micrometer-Sized Particles in the Extrathoracic Airways of Adults During Tidal Oral Breathing. Ann Biomed Eng 2013; 41:979-89. [DOI: 10.1007/s10439-013-0747-0] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2012] [Accepted: 01/18/2013] [Indexed: 11/26/2022]
|
22
|
Clark AR. Understanding Penetration Index Measurements and Regional Lung Targeting. J Aerosol Med Pulm Drug Deliv 2012; 25:179-87. [DOI: 10.1089/jamp.2011.0899] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|
23
|
Evans C, Cipolla D, Chesworth T, Agurell E, Ahrens R, Conner D, Dissanayake S, Dolovich M, Doub W, Fuglsang A, García Arieta A, Golden M, Hermann R, Hochhaus G, Holmes S, Lafferty P, Lyapustina S, Nair P, O'Connor D, Parkins D, Peterson I, Reisner C, Sandell D, Singh GJP, Weda M, Watson P. Equivalence considerations for orally inhaled products for local action-ISAM/IPAC-RS European Workshop report. J Aerosol Med Pulm Drug Deliv 2012; 25:117-39. [PMID: 22413806 DOI: 10.1089/jamp.2011.0968] [Citation(s) in RCA: 45] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
The purpose of this article is to document the discussions at the 2010 European Workshop on Equivalence Determinations for Orally Inhaled Drugs for Local Action, cohosted by the International Society for Aerosols in Medicine (ISAM) and the International Pharmaceutical Consortium on Regulation and Science (IPAC-RS). The article summarizes current regulatory approaches in Europe, the United States, and Canada, and presents points of consensus as well as ongoing debate in the four major areas: in vitro testing, pharmacokinetic and pharmacodynamic studies, and device similarity. Specific issues in need of further research and discussion are also identified.
Collapse
Affiliation(s)
- Carole Evans
- Catalent Pharma Solutions, Research Triangle Park, NC 27709, USA.
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
24
|
Conference Report: The 18th Congress of the International Society for Aerosols in Medicine. Ther Deliv 2011; 2:1115-9. [DOI: 10.4155/tde.11.85] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
The 18th biennial Congress of ISAM was held for 4 days at the De Doelen Congress Centre, Rotterdam, Netherlands, at which approximately 350 delegates, including 60 session chairs and speakers, attended. The abstracts of the 49 podium talks and the 126 posters that were presented have been published in the society’s technical journal (Journal of Aerosol Medicine and Pulmonary Delivery), and the detailed program can be found on the ISAM website ( www.isam.org ). Postgraduate courses on the topics: ‘Inhalation Therapy at the Intensive Care Unit’; ‘Walking the Standards Maze: Standards for Device Development, Device Performance and Regulatory Approval’; and ‘Nuts and Bolts of Aerosol Delivery: Theory, Guidelines and Practice’, were offered to participants prior to the Congress itself.