Colaianni-Alfonso N, Toledo A, Montiel G, Castro-Sayat M, Crimi C, Vetrugno L. High-flow nasal cannula and in-line aerosolised bronchodilator delivery during severe exacerbation of asthma in adults: a feasibility observational study. Anaesth Crit Care Pain Med 2024; 43:101414. [PMID: 39089455 DOI: 10.1016/j.accpm.2024.101414] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2024] [Revised: 07/02/2024] [Accepted: 07/19/2024] [Indexed: 08/04/2024]
Abstract
BACKGROUND Asthma is a common chronic respiratory disease affecting 1-29% of the population in different countries. Exacerbations represent a change in symptoms and lung function from the patient's usual condition that requires emergency department (ED) admission. Recently, the use of a High-Flow Nasal Cannula (HFNC) plus an in-line vibrating mesh nebulizer (VMN) for aerosol drug delivery has been advocated in clinical practice. Thus, this pilot observational study aims to investigate the feasibility of HFNC treatment with VMN for in-line bronchodilator delivery in patients with severe asthma. METHODS This study was conducted from May 2022 to May 2023. Subjects ≥18 years old with a previous diagnosis of asthma who were admitted to the ED during severe exacerbation were included. The primary endpoint was the change in peak expiratory flow ratio (PEFR) after 2-h of treatment with bronchodilator delivered by HFNC with in-line VMN. Additional outcomes were changes in forced expiratory volume in 1 s (FEV1) and clinical variables before treatment. RESULTS 30 patients, mean age of 43 (SD ± 16) years, mostly female (67%) were studied. A significant change in PEFR (147 ± 31 L/m vs. 220 ± 38 L/m; p < 0.001) was observed after treatment with HFNC and in-line VMN with significant improvement in clinical variables. And no subjects required invasive mechanical ventilation (IMV) during the study. CONCLUSIONS HFNC treatment with in-line VMN for bronchodilator delivery appears feasible and safe for patients with severe asthma exacerbation. These preliminary promising results should be confirmed with appropriately large-designed studies.
Collapse
Affiliation(s)
- Nicolás Colaianni-Alfonso
- Respiratory Intermediate Care Unit, Hospital Juan A. Fernández, Ciudad Autónoma de Buenos Aires, Argentina.
| | - Ada Toledo
- Respiratory Intermediate Care Unit, Hospital Juan A. Fernández, Ciudad Autónoma de Buenos Aires, Argentina
| | - Guillermo Montiel
- Respiratory Intermediate Care Unit, Hospital Juan A. Fernández, Ciudad Autónoma de Buenos Aires, Argentina
| | - Mauro Castro-Sayat
- Respiratory Intermediate Care Unit, Hospital Juan A. Fernández, Ciudad Autónoma de Buenos Aires, Argentina
| | - Claudia Crimi
- Respiratory Medicine Unit, Policlinico "G. Rodolico-San Marco" University Hospital, Catania, Italy; Department of Clinical and Experimental Medicine, University of Catania, Catania, Italy
| | - Luigi Vetrugno
- Department of Medical, Oral and Biotechnological Sciences, University of G. d' Annunzio, Chieti-Pescara, Italy.
| |
Collapse
|
2
|
Ari A, Hoops JA, Koyuncu A, Fink JB. Dos and don'ts to optimize transnasal aerosol drug delivery in clinical practice. Expert Opin Drug Deliv 2024; 21:1103-1114. [PMID: 39104360 DOI: 10.1080/17425247.2024.2388838] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2024] [Revised: 07/10/2024] [Accepted: 08/01/2024] [Indexed: 08/07/2024]
Abstract
INTRODUCTION Transnasal aerosol drug delivery has become widely accepted for treating acutely ill infants, children, and adults. More recently aerosol administration to wider populations receiving high and low-flow nasal oxygen has become common practice. AREAS COVERED Skepticism of insufficient aerosol delivery to the lungs has been tempered by multiple in vitro explorations of variables to optimize delivery efficiency. Additionally, clinical studies demonstrated comparable clinical responses to orally inhaled aerosols. This paper provides essential clinical guidance on how to improve transnasal aerosol delivery based on device-, settings-, and drug-related optimization to serve as a resource for educational initiatives and quality enhancement endeavors at healthcare institutions. EXPERT OPINION Transnasal aerosol delivery is proliferating worldwide, but indiscriminate use of excessive-high flows, poor selection and placement of aerosol devices and circuits can greatly reduce aerosol delivery and efficacy, potentially compromising treatment to acute and critically ill patients. Attention to these details can improve inhaled dose by an order of magnitude, making the difference between effective treatment and the progression to more invasive ventilatory support, with greater inherent risk and cost. These revelations have prompted specific recommendations for optimal delivery, driving advancements in aerosol generators, formulations, and future device designs to administer aerosols and maximize treatment effectiveness.
Collapse
Affiliation(s)
- Arzu Ari
- College of Health Professions, Department of Respiratory Care, Texas State University, Round Rock, TX, USA
| | - Jordan A Hoops
- College of Health Professions, Department of Respiratory Care, Texas State University, Round Rock, TX, USA
| | - Ayfer Koyuncu
- Bioengineering Division, College of Engineering, Hacettepe University, Ankara, Turkey
| | - James B Fink
- College of Health Professions, Department of Respiratory Care, Texas State University, Round Rock, TX, USA
| |
Collapse
|
3
|
MacLoughlin R, Mac Giolla Eain M. Performance Characterisation of the Airvo2 TM Nebuliser Adapter in Combination with the Aerogen Solo TM Vibrating Mesh Nebuliser for in Line Aerosol Therapy during High Flow Nasal Oxygen Therapy. Pharmaceutics 2024; 16:565. [PMID: 38675226 PMCID: PMC11053618 DOI: 10.3390/pharmaceutics16040565] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2024] [Revised: 04/16/2024] [Accepted: 04/17/2024] [Indexed: 04/28/2024] Open
Abstract
High flow oxygen (HFO) therapy is a well-established treatment in respiratory disease. Concurrent aerosol delivery can greatly expediate their recovery. The aim of this work was to complete a comprehensive characterisation of one such HFO therapy system, the Airvo2TM, used in combination with the Aerogen SoloTM vibrating mesh nebuliser. Representative adult, infant, and paediatric head models were connected to a breathing simulator via a collection filter placed at the level of the trachea. A tracheostomy interface and nasal cannulas were used to deliver the aerosol. Cannula size and gas flow rate were varied across the full operating range recommended by the manufacturer. The tracheal and emitted doses were quantified via UV-spectrophotometry. The aerosol droplet diameter at the exit of the nares and tracheal interface was measured via cascade impaction. High gas flow rates resulted in low emitted and tracheal doses (%). Nasal cannula size had no significant effect on the tracheal dose (%) available in infant and paediatric models. Higher gas flow rates resulted in smaller aerosol droplets at the exit of the nares and tracheostomy interface. Gas flow rate was found to be the primary parameter affecting aerosol delivery. Thus, gas flow rates should be kept low and where possible, delivered using larger nasal cannulas to maximise aerosol delivery.
Collapse
Affiliation(s)
- Ronan MacLoughlin
- Research and Development, Science and Emerging Technologies, Aerogen Ltd., Galway Business Park, H91 HE94 Galway, Ireland
- School of Pharmacy and Biomolecular Science, Royal College of Surgeons in Ireland, D02 YN77 Dublin, Ireland
- School of Pharmacy and Pharmaceutical Sciences, Trinity College, D02 PN40 Dublin, Ireland
| | - Marc Mac Giolla Eain
- Research and Development, Science and Emerging Technologies, Aerogen Ltd., Galway Business Park, H91 HE94 Galway, Ireland
| |
Collapse
|
4
|
Arnott A, Watson M, Sim M. Nebuliser therapy in critical care: The past, present and future. J Intensive Care Soc 2024; 25:78-88. [PMID: 39323591 PMCID: PMC11421288 DOI: 10.1177/17511437231199899] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/27/2024] Open
Abstract
Nebulisers are devices that reduce a body of liquid into a fine aerosol suitable for inhalation. Utilising the efficiency of pulmonary drug absorption, they offer a safe and powerful modality for local and systemic drug delivery in the treatment of critical illness. In comparison to conventional jet (JN) and ultrasonic nebulisers (USN), the advent of vibrating mesh nebulisers (VMN) has significantly improved the therapeutic potential of modern devices. This review article aims to summarise the history and evolution of nebulisers from first inception through to the modern vibrating mesh technology. It provides an overview on the basic science of nebulisation and pulmonary drug delivery, and the current use of nebulised therapies in critical care.
Collapse
Affiliation(s)
| | | | - Malcolm Sim
- Queen Elizabeth University Hospital, Glasgow, UK
| |
Collapse
|
5
|
Jayakumaran J, Smaldone GC. In Vivo Deposition of High-Flow Nasal Aerosols Using Breath-Enhanced Nebulization. Pharmaceutics 2024; 16:182. [PMID: 38399243 PMCID: PMC10891871 DOI: 10.3390/pharmaceutics16020182] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2023] [Revised: 01/12/2024] [Accepted: 01/22/2024] [Indexed: 02/25/2024] Open
Abstract
Aerosol delivery using conventional nebulizers with fixed maximal output rates is limited and unpredictable under high-flow conditions. This study measured regulated aerosol delivery to the lungs of normal volunteers using a nebulizer designed to overcome the limitations of HFNC therapy (i-AIRE (InspiRx, Inc., Somerset, NJ, USA)). This breath-enhanced jet nebulizer, in series with the high-flow catheter, utilizes the high flow to increase aerosol output beyond those of conventional devices. Nine normal subjects breathing tidally via the nose received humidified air at 60 L/min. The nebulizer was connected to the HFNC system upstream to the humidifier and received radio-labeled saline as a marker for drug delivery (99mTc DTPA) infused by a syringe pump (mCi/min). The dose to the subject was regulated at 12, 20 and 50 mL/h. Rates of aerosol deposition in the lungs (µCi/min) were measured via a gamma camera for each infusion rate and converted to µg NaCl/min. The deposition rate, as expressed as µg of NaCl/min, was closely related to the infusion rate: 7.84 ± 3.2 at 12 mL/h, 43.0 ± 12 at 20 mL/h and 136 ± 45 at 50 mL/h. The deposition efficiency ranged from 0.44 to 1.82% of infused saline, with 6% deposited in the nose. A regional analysis indicated peripheral deposition of aerosol (central/peripheral ratio 0.99 ± 0.27). The data were independent of breathing frequency. Breath-enhanced nebulization via HFNC reliably delivered aerosol to the lungs at the highest nasal airflows. The rate of delivery was controlled simply by regulating the infusion rate, indicating that lung deposition in the critically ill can be titrated clinically at the bedside.
Collapse
Affiliation(s)
- Jeyanthan Jayakumaran
- Division of Pulmonary, Critical Care and Sleep Medicine, Department of Medicine, Stony Brook University Medical Center, Stony Brook, NY 11794, USA;
| | | |
Collapse
|
6
|
Mac Giolla Eain M, MacLoughlin R. In-Line Aerosol Therapy via Nasal Cannula during Adult and Paediatric Normal, Obstructive, and Restrictive Breathing. Pharmaceutics 2023; 15:2679. [PMID: 38140020 PMCID: PMC10747070 DOI: 10.3390/pharmaceutics15122679] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2023] [Revised: 11/20/2023] [Accepted: 11/23/2023] [Indexed: 12/24/2023] Open
Abstract
High-flow nasal oxygen therapy is being increasingly adopted in intensive and home care settings. The concurrent delivery of aerosolised therapeutics allows for the targeted treatment of respiratory illnesses. This study examined in-line aerosol therapy via a nasal cannula to simulated adult and paediatric models with healthy, obstructive and restrictive lung types. The Aerogen Solo vibrating mesh nebuliser was used in combination with the InspiredTM O2FLO high-flow therapy system. Representative adult and paediatric head models were connected to a breathing simulator, which replicated several different states of lung health. The aerosol delivery was quantified at the tracheal level using UV-spectrophotometry. Testing was performed at a range of supplemental gas flow rates applicable to both models. Positive end-expiratory pressure was measured pre-, during and post-nebulisation. The increases in supplemental gas flow rates resulted in a decrease in aerosol delivery, irrespective of lung health. Large tidal volumes and extended inspiratory phases were associated with the greatest aerosol delivery. Gas flow to inspiratory flow ratios of 0.29-0.5 were found to be optimum for aerosol delivery. To enhance aerosol delivery to patients receiving high-flow nasal oxygen therapy, respiratory therapists should keep supplemental gas-flow rates below the inspiratory flow of the patient.
Collapse
Affiliation(s)
- Marc Mac Giolla Eain
- Research and Development, Science and Emerging Technologies, Aerogen Ltd., Galway Business Park, H91 HE94 Galway, Ireland
| | - Ronan MacLoughlin
- Research and Development, Science and Emerging Technologies, Aerogen Ltd., Galway Business Park, H91 HE94 Galway, Ireland
- School of Pharmacy and Biomolecular Science, Royal College of Surgeons in Ireland, D02 YN77 Dublin, Ireland
- School of Pharmacy and Pharmaceutical Sciences, Trinity College, D02 PN40 Dublin, Ireland
| |
Collapse
|
7
|
Huang Y, Zhao J, Hua X, Luo K, Shi Y, Lin Z, Tang J, Feng Z, Mu D. Guidelines for high-flow nasal cannula oxygen therapy in neonates (2022). J Evid Based Med 2023; 16:394-413. [PMID: 37674304 DOI: 10.1111/jebm.12546] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/17/2023] [Accepted: 08/16/2023] [Indexed: 09/08/2023]
Abstract
High-flow nasal cannula (HFNC) oxygen therapy, which is important in noninvasive respiratory support, is increasingly being used in critically ill neonates with respiratory failure because it is comfortable, easy to setup, and has a low incidence of nasal trauma. The advantages, indications, and risks of HFNC have been the focus of research in recent years, resulting in the development of the application. Based on current evidence, we developed guidelines for HFNC in neonates using the Grading of Recommendations Assessment, Development and Evaluation (GRADE). The guidelines were formulated after extensive consultations with neonatologists, respiratory therapists, nurse specialists, and evidence-based medicine experts. We have proposed 24 recommendations for 9 key questions. The guidelines aim to be a source of evidence and reference of HFNC oxygen therapy in clinical practice, and so that more neonates and their families will benefit from HFNC.
Collapse
Affiliation(s)
- Yi Huang
- Department of Neonatology, West China Second University Hospital, Sichuan University, Chengdu, P.R. China
| | - Jing Zhao
- Department of Neonatology, West China Second University Hospital, Sichuan University, Chengdu, P.R. China
- Key Laboratory of Birth Defects and Related Diseases of Women and Children, Ministry of Education, Chengdu, P.R. China
| | - Xintian Hua
- Department of Neonatology, West China Second University Hospital, Sichuan University, Chengdu, P.R. China
- Key Laboratory of Birth Defects and Related Diseases of Women and Children, Ministry of Education, Chengdu, P.R. China
| | - Keren Luo
- Department of Neonatology, West China Second University Hospital, Sichuan University, Chengdu, P.R. China
- Key Laboratory of Birth Defects and Related Diseases of Women and Children, Ministry of Education, Chengdu, P.R. China
| | - Yuan Shi
- Department of Neonatology, Children's Hospital of Chongqing Medical University, Chongqing, P.R. China
| | - Zhenlang Lin
- Department of Neonatology, The Second Affiliated Hospital of Wenzhou Medical University, Wenzhou, P.R. China
| | - Jun Tang
- Department of Neonatology, West China Second University Hospital, Sichuan University, Chengdu, P.R. China
- Key Laboratory of Birth Defects and Related Diseases of Women and Children, Ministry of Education, Chengdu, P.R. China
| | - Zhichun Feng
- Department of Neonatology, Faculty of Pediatrics, Chinese PLA General Hospital, Beijing, P.R. China
| | - Dezhi Mu
- Department of Neonatology, West China Second University Hospital, Sichuan University, Chengdu, P.R. China
- Key Laboratory of Birth Defects and Related Diseases of Women and Children, Ministry of Education, Chengdu, P.R. China
| |
Collapse
|
8
|
Li J, Liu K, Lyu S, Jing G, Dai B, Dhand R, Lin HL, Pelosi P, Berlinski A, Rello J, Torres A, Luyt CE, Michotte JB, Lu Q, Reychler G, Vecellio L, de Andrade AD, Rouby JJ, Fink JB, Ehrmann S. Aerosol therapy in adult critically ill patients: a consensus statement regarding aerosol administration strategies during various modes of respiratory support. Ann Intensive Care 2023; 13:63. [PMID: 37436585 DOI: 10.1186/s13613-023-01147-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2023] [Accepted: 05/31/2023] [Indexed: 07/13/2023] Open
Abstract
BACKGROUND Clinical practice of aerosol delivery in conjunction with respiratory support devices for critically ill adult patients remains a topic of controversy due to the complexity of the clinical scenarios and limited clinical evidence. OBJECTIVES To reach a consensus for guiding the clinical practice of aerosol delivery in patients receiving respiratory support (invasive and noninvasive) and identifying areas for future research. METHODS A modified Delphi method was adopted to achieve a consensus on technical aspects of aerosol delivery for adult critically ill patients receiving various forms of respiratory support, including mechanical ventilation, noninvasive ventilation, and high-flow nasal cannula. A thorough search and review of the literature were conducted, and 17 international participants with considerable research involvement and publications on aerosol therapy, comprised a multi-professional panel that evaluated the evidence, reviewed, revised, and voted on recommendations to establish this consensus. RESULTS We present a comprehensive document with 20 statements, reviewing the evidence, efficacy, and safety of delivering inhaled agents to adults needing respiratory support, and providing guidance for healthcare workers. Most recommendations were based on in-vitro or experimental studies (low-level evidence), emphasizing the need for randomized clinical trials. The panel reached a consensus after 3 rounds anonymous questionnaires and 2 online meetings. CONCLUSIONS We offer a multinational expert consensus that provides guidance on the optimal aerosol delivery techniques for patients receiving respiratory support in various real-world clinical scenarios.
Collapse
Affiliation(s)
- Jie Li
- Department of Cardiopulmonary Sciences, Division of Respiratory Care, Rush University, 600 S Paulina St, Suite 765, Chicago, IL, 60612, USA.
| | - Kai Liu
- Department of Critical Care Medicine, Zhongshan Hospital, Fudan University, Shanghai, China
| | - Shan Lyu
- Critical Care Medicine, Peking University People's Hospital, Beijing, China
| | - Guoqiang Jing
- Department of Critical Care Medicine, Binzhou Medical University Hospital, Binzhou, China
| | - Bing Dai
- Department of Respiratory and Critical Care Medicine, The First Affiliated Hospital of China Medical University, Shenyang, China
| | - Rajiv Dhand
- Department of Medicine, University of Tennessee Graduate School of Medicine, Knoxville, TN, USA
| | - Hui-Ling Lin
- Department of Respiratory Therapy, Chang Gung University, Taoyuan, Taiwan
| | - Paolo Pelosi
- Anesthesiology and Critical Care, San Martino Policlinico Hospital, IRCCS for Oncology and Neurosciences, Genoa, Italy
- Department of Surgical Sciences and Integrated Diagnostics, University of Genoa, Genoa, Italy
| | - Ariel Berlinski
- Pulmonary and Sleep Medicine Division, Department of Pediatrics, University of Arkansas for Medical Sciences, and Pediatric Aerosol Research Laboratory at Arkansas Children's Research Institute, Little Rock, AR, USA
| | - Jordi Rello
- Clinical Research/Epidemiology in Pneumonia and Sepsis (CRIPS), Vall d'Hebron Institute of Research (VHIR), Barcelona, Spain
- Centro de Investigación Biomédica en Red de Enfermedades Respiratorias (CIBERES), Instituto de Salud Carlos III, Madrid, Spain
- Clinical Research in the ICU, Anaesthesia Department, CHU Nimes, Université de Nimes-Montpellier, Nimes, France
| | - Antoni Torres
- Servei de Pneumologia, Hospital Clinic, University of Barcelona, IDIBAPS CIBERES, Icrea, Barcelona, Spain
- Centro de Investigación Biomédica en Red de Enfermedades Respiratorias (CIBERES), Instituto de Salud Carlos III, Madrid, Spain
| | - Charles-Edouard Luyt
- Médecine Intensive Réanimation, Institut de Cardiologie, Groupe Hospitalier Pitié-Salpêtrière, Assistance Publique-Hôpitaux de Paris, Sorbonne-Université, and INSERM, UMRS_1166-ICAN Institute of Cardiometabolism and Nutrition, Paris, France
| | - Jean-Bernard Michotte
- School of Health Sciences (HESAV), HES-SO University of Applied Sciences and Arts of Western Switzerland, Lausanne, Switzerland
| | - Qin Lu
- Department of Emergency Medicine, Second Affiliated Hospital, Zhejiang Province Clinical Research Center for Emergency and Critical Care Medicine, and Key Laboratory of the Diagnosis and Treatment of Severe Trauma and Burn of Zhejiang Province, Zhejiang University School of Medicine, Hangzhou, China
| | - Gregory Reychler
- Secteur de Kinésithérapie et Ergothérapie, Cliniques Universitaires Saint-Luc, Brussels, Belgium
- Service de Pneumologie, Cliniques Universitaires Saint-Luc, Brussels, Belgium
- Institut de Recherche Expérimentale et Clinique (IREC), Pôle de Pneumologie, ORL and Dermatologie, Université Catholique de Louvain, Brussels, Belgium
| | | | | | - Jean-Jacques Rouby
- Research Department DMU DREAM and Multidisciplinary Intensive Care Unit, Department of Anesthesiology and Critical Care, La Pitié-Salpêtrière Hospital, Sorbonne University of Paris, Paris, France
| | - James B Fink
- Department of Cardiopulmonary Sciences, Division of Respiratory Care, Rush University, 600 S Paulina St, Suite 765, Chicago, IL, 60612, USA
- Chief Science Officer, Aerogen Pharma Corp, San Mateo, CA, USA
| | - Stephan Ehrmann
- CHRU Tours, Médecine Intensive Réanimation, CIC INSERM 1415, CRICS-TriggerSep F-CRIN Research Network, and INSERM, Centre d'étude des Pathologies Respiratoires, U1100, Université de Tours, Tours, France
| |
Collapse
|
9
|
Rello J, Bouglé A, Rouby JJ. Aerosolised antibiotics in critical care. Intensive Care Med 2023; 49:848-852. [PMID: 37085635 DOI: 10.1007/s00134-023-07036-5] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2023] [Accepted: 03/11/2023] [Indexed: 04/23/2023]
Affiliation(s)
- Jordi Rello
- Global Health eCore, Vall d'Hebron Institute of Research (VHIR), Ps. Vall d'Hebron 129. AMI-14, 08035, Barcelona, Spain.
- Centro de Investigacion Biomedica en Red de Enfermedades Respiratorias (CIBERES), Instituto de Salud Carlos III, Madrid, Spain.
- Unité de Recherche FOVERA, Réanimation Douleur Urgences, Centre Hospitalier Universitaire de Nîmes, Nîmes, France.
| | - Adrien Bouglé
- Cardiovascular Intensive Care Unit, Department of Anaesthesiology and Critical Care, La Pitié-Salpêtrière Hospital, Assistance Publique Hôpitaux de Paris, Paris, France
| | - Jean-Jacques Rouby
- Research Department, Departement Médico-Universitaire DREAM (DMU DREAM), Sorbonne University of Paris, Paris, France
| |
Collapse
|
10
|
MacLoughlin R, Martin-Loeches I. Not all nebulizers are created equal: Considerations in choosing a nebulizer for aerosol delivery during mechanical ventilation. Expert Rev Respir Med 2023; 17:131-142. [PMID: 36803134 DOI: 10.1080/17476348.2023.2183194] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/22/2023]
Abstract
INTRODUCTION Aerosol therapy is commonly prescribed in the mechanically ventilated patient. Jet nebulizers (JN) and vibrating mesh nebulizers (VMN) are the most common nebulizer types, however, despite VMN's well established superior performance, JN use remains the most commonly used of the two. In this review, we describe the key differentiators between nebulizer types and how considered selection of nebulizer type may enable successful therapy and the optimization of drug/device combination products. AREAS COVERED Following a review of the published literature up to February 2023, the current state of the art in relation to JN and VMN is discussed under the headings of in vitro performance of nebulizers during mechanical ventilation, respective compatibility with formulations for inhalation, clinical trials making use of VMN during mechanical ventilation, distribution of nebulized aerosol throughout the lung, measuring the respective performance of nebulizers in the patient and non-drug delivery considerations in nebulizer choice. EXPERT OPINION Whether for standard care, or the development of drug/device combination products, the choice of nebulizer type should not be made without consideration of the unique needs of the combination of each of drug, disease and patient types, as well as target site for deposition, and healthcare professional and patient safety.
Collapse
Affiliation(s)
- Ronan MacLoughlin
- Research and Development, Science and Emerging Technologies, Aerogen Ltd, Dangan, Ireland.,School of Pharmacy and Pharmaceutical Sciences, Trinity College, Dublin, Ireland.,School of Pharmacy and Biomolecular Sciences, Royal College of Surgeons in Ireland (RCSI), Dublin, Ireland
| | - Ignacio Martin-Loeches
- Department of Intensive Care Medicine, Multidisciplinary Intensive Care Research Organization (MICRO), Dublin, Ireland
| |
Collapse
|
11
|
Calabrese C, Annunziata A, Mariniello DF, Allocca V, Imitazione P, Cauteruccio R, Simioli F, Fiorentino G. Aerosol delivery through high-flow nasal therapy: Technical issues and clinical benefits. Front Med (Lausanne) 2023; 9:1098427. [PMID: 36743674 PMCID: PMC9889634 DOI: 10.3389/fmed.2022.1098427] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2022] [Accepted: 12/26/2022] [Indexed: 01/20/2023] Open
Abstract
High-flow nasal cannula (HFNC) therapy is an oxygen delivery method particularly used in patients affected by hypoxemic respiratory failure. In comparison with the conventional "low flow" oxygen delivery systems, it showed several important clinical benefits. The possibility to nebulize drugs via HFNC represents a desirable medical practice because it allows the administration of inhaled drugs, mostly bronchodilators, without the interruption or modification of the concomitant oxygen therapy. HFNC, by itself has shown to exert a small but significant bronchodilator effect and improves muco-ciliary clearance; thus, the nebulization of bronchodilators through the HFNC circuit may potentially increase their pharmacological activity. Several technical issues have been observed which include the type of the nebulizer that should be used, its position within the HFNC circuit, and the optimal gas flow rates to ensure an efficient drug delivery to the lungs both in "quiet" and "distressed" breathing patterns. The aim of this review has been to summarize the scientific evidence coming from "in vitro" studies and to discuss the results of "in vivo" studies performed in adult subjects, mainly affected by obstructive lung diseases. Most studies seem to indicate the vibrating mesh nebulizer as the most efficient type of nebulizer and suggest to place it preferentially upstream from the humidifier chamber. In a quite breathing patterns, the inhaled dose seems to increase with lower flow rates while in a "distressed" breathing pattern, the aerosol delivery is higher when gas flow was set below the patient's inspiratory flow, with a plateau effect seen when the gas flow reaches approximately 50% of the inspiratory flow. Although several studies have demonstrated that the percentage of the loaded dose nebulized via HFNC reaching the lungs is small, the bronchodilator effect of albuterol seems not to be impaired when compared to the conventional inhaled delivery methods. This is probably attributed to its pharmacological activity. Prospective and well-designed studies in different cohort of patients are needed to standardize and demonstrate the efficacy of the procedure.
Collapse
Affiliation(s)
- Cecilia Calabrese
- Department of Translational Medical Sciences, University of Campania “Luigi Vanvitelli”, Naples, Italy,*Correspondence: Cecilia Calabrese,
| | - Anna Annunziata
- Department of Intensive Care, Azienda Ospedaliera di Rilievo Nazionale dei Colli, Naples, Italy
| | | | - Valentino Allocca
- Department of Translational Medical Sciences, University of Campania “Luigi Vanvitelli”, Naples, Italy
| | - Pasquale Imitazione
- Department of Intensive Care, Azienda Ospedaliera di Rilievo Nazionale dei Colli, Naples, Italy
| | - Rosa Cauteruccio
- Department of Intensive Care, Azienda Ospedaliera di Rilievo Nazionale dei Colli, Naples, Italy
| | - Francesca Simioli
- Department of Intensive Care, Azienda Ospedaliera di Rilievo Nazionale dei Colli, Naples, Italy
| | - Giuseppe Fiorentino
- Department of Intensive Care, Azienda Ospedaliera di Rilievo Nazionale dei Colli, Naples, Italy
| |
Collapse
|
12
|
McGrath JA, O’Sullivan A, Joyce M, Byrne MA, Li J, Fink JB, MacLoughlin R. In vitro model for investigating aerosol dispersion in a simulated COVID-19 patient during high-flow nasal cannula treatment. Front Med (Lausanne) 2022; 9:1002659. [PMID: 36530866 PMCID: PMC9751314 DOI: 10.3389/fmed.2022.1002659] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2022] [Accepted: 11/14/2022] [Indexed: 08/05/2023] Open
Abstract
The use of high-flow nasal cannula in the treatment of COVID-19 infected patients has proven to be a valuable treatment option to improve oxygenation. Early in the pandemic, there were concerns for the degree of risk of disease transmission to health care workers utilizing these treatments that are considered aerosol generating procedures. This study developed an in vitro model to examine the release of simulated patient-derived bioaerosol with and without high-flow nasal cannula at gas flow rates of 30 and 50 L/min. Aerosol dispersion was evaluated at 30 and 90 cm distances. Reduction of transmission risk was assessed using a surgical facemask on the manikin. Results indicated that the use of a facemask facilitated a 94-95% reduction in exhaled aerosol concentration at 30 cm and 22-60% reduction for 90 cm distance across both gas flow rates. This bench study confirms that this in vitro model can be used as a tool to assess the risk of disease transmission during aerosol generating procedures in a simulated patient and to test factors to mitigate the risk.
Collapse
Affiliation(s)
- James A. McGrath
- Department of Physics, School of Natural Science, Ryan Institute’s Centre for Climate & Air Pollution Studies, University of Galway, Galway, Ireland
| | - Andrew O’Sullivan
- Research & Development, Science & Emerging Technologies, Aerogen Limited, Galway, Ireland
| | - Mary Joyce
- Research & Development, Science & Emerging Technologies, Aerogen Limited, Galway, Ireland
| | - Miriam A. Byrne
- Department of Physics, School of Natural Science, Ryan Institute’s Centre for Climate & Air Pollution Studies, University of Galway, Galway, Ireland
| | - Jie Li
- Division of Respiratory Care, Department of Cardiopulmonary Sciences, Rush University Medical Center, Chicago, IL, United States
| | - James B. Fink
- Aerogen Pharma Corporation, San Mateo, CA, United States
| | - Ronan MacLoughlin
- Research & Development, Science & Emerging Technologies, Aerogen Limited, Galway, Ireland
- School of Pharmacy and Biomolecular Sciences, Royal College of Surgeons in Ireland, Dublin, Ireland
- School of Pharmacy and Pharmaceutical Sciences, Trinity College Dublin, Dublin, Ireland
| |
Collapse
|
13
|
Spence BM, Longest W, Dutta R, Momin MAM, Strickler S, Hindle M. In Vitro Evaluation of Nebulized Pharmaceutical Aerosol Delivery to the Lungs Using a New Heated Dryer System (HDS). AAPS PharmSciTech 2022; 24:10. [PMID: 36451052 PMCID: PMC9994751 DOI: 10.1208/s12249-022-02460-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2022] [Accepted: 11/04/2022] [Indexed: 12/02/2022] Open
Abstract
The objective of this study was to develop a new heated dryer system (HDS) for high efficiency lung delivery of nebulized aerosol and demonstrate performance with realistic in vitro testing for trans-nasal aerosol administration simultaneously with high-flow nasal cannula (HFNC) therapy and separately for direct oral inhalation (OI) of the aerosol. With the HDS-HFNC and HDS-OI platforms, new active synchronization control routines were developed to sense subject inhalation and coordinate drug aerosol delivery. In vitro experiments were conducted to predict regional drug loss and lung delivery efficiency in systems that included the HDS with various patient interfaces, realistic airway models, and simulated breathing waveforms. For the HDS-HFNC platform and a repeating breathing waveform, total system loss was < 10%, extrathoracic deposition was approximately 6%, and best-case lung delivery efficiency was 75-78% of nebulized dose. Inclusion of randomized breathing with the HFNC system decreased lung delivery efficiency by ~ 10% and had no impact on nasal depositional loss. For the HDS-OI platform and best-case mouthpiece, total system loss was < 8%, extrathoracic deposition was < 1%, and lung delivery efficiency was > 90% of nebulized dose. Normal vs. deep randomized oral inhalation had little impact on performance of the HDS-OI platform and environmental aerosol loss was negligible. In conclusion, both platforms demonstrated the potential for high efficiency lung delivery of the aerosol with the HDS-OI platform having the added advantages of nearly eliminating extrathoracic deposition, being insensitive to breathing waveform, and preventing environmental aerosol loss.
Collapse
Affiliation(s)
- Benjamin M Spence
- Department of Mechanical and Nuclear Engineering, Virginia Commonwealth University, Richmond, Virginia, USA
| | - Worth Longest
- Department of Mechanical and Nuclear Engineering, Virginia Commonwealth University, Richmond, Virginia, USA.
- Department of Pharmaceutics, Virginia Commonwealth University, Richmond, Virginia, USA.
| | - Rabijit Dutta
- Department of Mechanical and Nuclear Engineering, Virginia Commonwealth University, Richmond, Virginia, USA
| | - Mohammad A M Momin
- Department of Pharmaceutics, Virginia Commonwealth University, Richmond, Virginia, USA
| | - Sarah Strickler
- Department of Mechanical and Nuclear Engineering, Virginia Commonwealth University, Richmond, Virginia, USA
| | - Michael Hindle
- Department of Pharmaceutics, Virginia Commonwealth University, Richmond, Virginia, USA
| |
Collapse
|
14
|
Ari A, Fink JB. Delivered dose with jet and mesh nebulisers during spontaneous breathing, noninvasive ventilation and mechanical ventilation using adult lung models. ERJ Open Res 2021; 7:00027-2021. [PMID: 34262965 PMCID: PMC8273293 DOI: 10.1183/23120541.00027-2021] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2021] [Accepted: 04/20/2021] [Indexed: 11/05/2022] Open
Abstract
What is the delivered dose with jet and mesh nebulisers during spontaneous breathing (SB), noninvasive ventilation (NIV), and mechanical ventilation (MV) using an adult lung model with exhaled humidity (EH)? The delivery of salbutamol sulfate (2.5 mg per 3 mL) with jet (Mistymax10) and mesh nebulisers (Aerogen Solo) was compared during SB, NIV, and MV using breathing parameters (tidal volume 450 mL, respiratory rate 20 breaths per min, inspiratory:expiratory ratio 1:3) with three lung models simulating exhaled humidity. A manikin was attached to a sinusoidal pump via a filter at the bronchi to simulate an adult with SB. A ventilator (V60) was attached via a facemask to a manikin with a filter at the bronchi connected to a test lung to simulate an adult receiving NIV. A ventilator-dependent adult was simulated through a ventilator (Servo-i) operated with a heated humidifier (Fisher & Paykel) attached to an endotracheal tube (ETT) with a heated-wire circuit. The ETT was inserted into a filter (Respirgard II). A heated humidifier was placed between the filter and test lung to simulate exhaled humidity (35±2°C, 100% relative humidity). Nebulisers were placed at the Y-piece of the inspiratory limb during MV and positioned between the facemask and the leak-port during NIV. A mouthpiece was used during SB. The delivered dose was collected in an absolute filter that was attached to the bronchi of the mannequin during each aerosol treatment and measured with spectrophotometry. Drug delivery during MV was significantly greater than during NIV and SB with a mesh nebuliser (p=0.0001) but not with a jet nebuliser (p=0.384). Delivery efficiency of the mesh nebuliser was greater than the jet nebuliser during MV (p=0.0001), NIV (p=0.0001), and SB (p=0.0001). Aerosol deposition obtained with a mesh nebuliser was greater and differed between MV, NIV, and SB, while deposition was low with a jet nebuliser and similar between the modes of ventilation tested.
Collapse
Affiliation(s)
- Arzu Ari
- Dept of Respiratory Care, Texas State University, Round Rock, TX, USA
| | - James B Fink
- Dept of Respiratory Care, Texas State University, Round Rock, TX, USA
| |
Collapse
|
15
|
Li J, Fink JB. Narrative review of practical aspects of aerosol delivery via high-flow nasal cannula. ANNALS OF TRANSLATIONAL MEDICINE 2021; 9:590. [PMID: 33987288 DOI: 10.21037/atm-20-7383] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Using high-flow nasal cannula (HFNC) as a "vehicle" to administer aerosolized medication has attracted clinicians' interest in recent years. In this paper, we summarize the current evidence to answer the common questions raised by clinicians about this new aerosol delivery route and best practices of administration. Benefits of trans-nasal aerosol delivery include increased comfort, ability to speak, eat, and drink for patients while meeting a range of oxygen requirements, particularly for those who need to inhale aerosolized medication for long periods. Aerosol administration via HFNC has been shown to be well tolerated by children and adults, with comparable or better delivery efficacy than other interfaces, ranging from 2-20%. In vitro and in vivo scintigraphy studies among pediatric and adult populations reported that the inhaled dose delivered via a vibrating mesh nebulizer is 2 to 3 fold greater than that via a jet nebulizer. For adults, placement of nebulizer at the inlet of humidifier increases inhaled dose while reducing rainout obstructing nasal prongs. When HFNC gas flow is set below patient inspiratory flow, aerosol deposition is higher than when the gas flow exceeds patient inspiratory flow; thus, if tolerated, titrating down HFNC gas flow during trans-nasal aerosol delivery, with close monitoring and the use of unit dose with high concentration are recommended. Trans-nasal pulmonary aerosol delivery has not been shown to increase bioaerosols generated by patients, but gas flow may disperse aerosols. Placement of a surgical or procedure mask over HFNC might reduce aerosol dispersion.
Collapse
Affiliation(s)
- Jie Li
- Department of Cardiopulmonary Sciences, Division of Respiratory Care, Rush University Medical Center, Chicago, IL, USA
| | - James B Fink
- Department of Cardiopulmonary Sciences, Division of Respiratory Care, Rush University Medical Center, Chicago, IL, USA.,Aerogen Pharma Corp, San Mateo, CA, USA
| |
Collapse
|
16
|
Ari A, Moody GB. How to deliver aerosolized medications through high flow nasal cannula safely and effectively in the era of COVID-19 and beyond: A narrative review. ACTA ACUST UNITED AC 2021; 57:22-25. [PMID: 33688576 PMCID: PMC7932031 DOI: 10.29390/cjrt-2020-041] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Background The treatments of COVID-19 involve some degree of uncertainty. Current evidence also shows mixed findings with regards to bioaerosol dispersion and airborne transmission of COVID-19 during high flow nasal cannula (HFNC) therapy. While coping with this global pandemic created hot debates on the use of HFNC, it is important to bring detached opinions and current evidence to the attention of health care professionals (HCPs) who may need to use HFNC in patients with COVID-19. Aim The purpose of this paper is to provide a framework on the selection, placement, and use of nebulizers as well as HFNC prongs, gas flow, and delivery technique via HFNC to help clinicians deliver aerosolized medications through HFNC safely and effectively in the era of COVID-19 and beyond. Methods We searched PubMed, Medline, CINAHL, and Science Direct to identify studies on aerosol drug delivery through HFNC using the following keywords: (“aerosols,” OR “nebulizers”) AND (“high flow nasal cannula” OR “high flow oxygen therapy” OR “HFNC”) AND (“COVID-19,” OR “SARS-CoV-2”). Twenty-eight articles including in vitro studies, randomized clinical trials, scintigraphy studies, review articles, prospective and retrospective research were included in this review. Discussion and results It is not clear if the findings of the previous studies on bacterial contamination could be applied to viral transmission because they do not provide data that could be extrapolated to the risk of SARS-CoV-2 transmission. In the face of the unknown risk with the transmission of COVID-19 during HFNC therapy, the benefits of HFNC must be weighed against the risk of infection to HCPs and other patients. Due to the limited number of ventilators available in hospitals and the confirmed effectiveness of HFNC in treating hypoxemic respiratory failure, HFNC may prevent early intubation, and prolonged intensive care unit stays in patients with COVID-19. Conclusion Clinicians should review the magnitude of this risk based on current evidence and use the suggested strategies of this paper for safe and effective delivery of aerosolized medications through HFNC in the era of COVID-19 and beyond.
Collapse
Affiliation(s)
- Arzu Ari
- Department of Respiratory Therapy, Texas State University, Round Rock, TX, USA
| | - Gerald B Moody
- Children's Health - Children's Medical Center, Department of Respiratory Care, Dallas, TX, USA
| |
Collapse
|
17
|
CFD Guided Optimization of Nose-to-Lung Aerosol Delivery in Adults: Effects of Inhalation Waveforms and Synchronized Aerosol Delivery. Pharm Res 2020; 37:199. [PMID: 32968848 DOI: 10.1007/s11095-020-02923-8] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2020] [Accepted: 09/01/2020] [Indexed: 12/27/2022]
Abstract
PURPOSE The objective of this study was to optimize nose-to-lung aerosol delivery in an adult upper airway model using computational fluid dynamics (CFD) simulations in order to guide subsequent human subject aerosol delivery experiments. METHODS A CFD model was developed that included a new high-flow nasal cannula (HFNC) and pharmaceutical aerosol delivery unit, nasal cannula interface, and adult upper airway geometry. Aerosol deposition predictions in the system were validated with existing and new experimental results. The validated CFD model was then used to explore aerosol delivery parameters related to synchronizing aerosol generation with inhalation and inhalation flow rate. RESULTS The low volume of the new HFNC unit minimized aerosol transit time (0.2 s) and aerosol bolus spread (0.1 s) enabling effective synchronization of aerosol generation with inhalation. For aerosol delivery correctly synchronized with inhalation, a small particle excipient-enhanced growth delivery strategy reduced nasal cannula and nasal depositional losses each by an order of magnitude and enabled ~80% of the nebulized dose to reach the lungs. Surprisingly, nasal deposition was not sensitive to inhalation flow rate due to use of a nasal cannula interface with co-flow inhaled air and the small initial particle size. CONCLUSIONS The combination of correct aerosol synchronization and small particle size enabled high efficiency nose-to-lung aerosol delivery in adults, which was not sensitive to inhalation flow rate.
Collapse
|
18
|
Li J, Fink JB, MacLoughlin R, Dhand R. A narrative review on trans-nasal pulmonary aerosol delivery. CRITICAL CARE : THE OFFICIAL JOURNAL OF THE CRITICAL CARE FORUM 2020; 24:506. [PMID: 32807226 PMCID: PMC7430014 DOI: 10.1186/s13054-020-03206-9] [Citation(s) in RCA: 30] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/01/2020] [Accepted: 07/27/2020] [Indexed: 01/21/2023]
Abstract
The use of trans-nasal pulmonary aerosol delivery via high-flow nasal cannula (HFNC) has expanded in recent years. However, various factors influencing aerosol delivery in this setting have not been precisely defined, and no consensus has emerged regarding the optimal techniques for aerosol delivery with HFNC. Based on a comprehensive literature search, we reviewed studies that assessed trans-nasal pulmonary aerosol delivery with HFNC by in vitro experiments, and in vivo, by radiolabeled, pharmacokinetic and pharmacodynamic studies. In these investigations, the type of nebulizer employed and its placement, carrier gas, the relationship between gas flow and patient’s inspiratory flow, aerosol delivery strategies (intermittent unit dose vs continuous administration by infusion pump), and open vs closed mouth breathing influenced aerosol delivery. The objective of this review was to provide rational recommendations for optimizing aerosol delivery with HFNC in various clinical settings.
Collapse
Affiliation(s)
- Jie Li
- Division of Respiratory Care, Department of Cardiopulmonary Sciences, Rush University Medical Center, 1620 W Harrison St, Tower LL1202, Chicago, IL, 60612, USA.
| | - James B Fink
- Division of Respiratory Care, Department of Cardiopulmonary Sciences, Rush University Medical Center, 1620 W Harrison St, Tower LL1202, Chicago, IL, 60612, USA.,Aerogen Pharma Corp, San Mateo, CA, USA
| | | | - Rajiv Dhand
- Department of Medicine, University of Tennessee Graduate School of Medicine, Knoxville, TN, USA
| |
Collapse
|
19
|
Dugernier J, Reychler G, Vecellio L, Ehrmann S. Nasal High-Flow Nebulization for Lung Drug Delivery: Theoretical, Experimental, and Clinical Application. J Aerosol Med Pulm Drug Deliv 2019; 32:341-351. [PMID: 31084452 DOI: 10.1089/jamp.2019.1524] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022] Open
Affiliation(s)
- Jonathan Dugernier
- Institut de Recherche Expérimentale et Clinique (IREC), Pneumologie, ORL & Dermatologie, Cliniques universitaires Saint-Luc, Brussels, Belgium
- Soins Intensifs, Cliniques universitaires Saint-Luc, Brussels, Belgium
- Médecine Physique, Cliniques universitaires Saint-Luc, Brussels, Belgium
| | - Grégory Reychler
- Institut de Recherche Expérimentale et Clinique (IREC), Pneumologie, ORL & Dermatologie, Cliniques universitaires Saint-Luc, Brussels, Belgium
- Service de pneumologie, Cliniques universitaires Saint-Luc, Brussels, Belgium
| | - Laurent Vecellio
- Centre d'études des pathologies respiratoires, INSERM U1100, Faculté de médecine, Université de Tours, Tours, France
| | - Stephan Ehrmann
- Centre d'études des pathologies respiratoires, INSERM U1100, Faculté de médecine, Université de Tours, Tours, France
- Médecine intensive réanimation, Centre d'investigation clinique CIC INSERM 1415, CHRU de Tours, Tours, France
- CRICS-TriggerSep Research Network
| |
Collapse
|
20
|
McCarthy SD, Horgan E, Ali A, Masterson C, Laffey JG, MacLoughlin R, O'Toole D. Nebulized Mesenchymal Stem Cell Derived Conditioned Medium Retains Antibacterial Properties Against Clinical Pathogen Isolates. J Aerosol Med Pulm Drug Deliv 2019; 33:140-152. [PMID: 31730399 DOI: 10.1089/jamp.2019.1542] [Citation(s) in RCA: 26] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023] Open
Abstract
Background: Mesenchymal stem/stromal cells (MSCs) have demonstrated promise in pathogenic acute respiratory distress syndrome models and are advancing to clinical efficacy testing. Besides immunomodulatory effects, MSC derived conditioned medium (CM) has direct antibacterial effects, possibly through LL-37 and related secreted peptide activity. We investigated MSC-CM compatibility with vibrating mesh technology, allowing direct delivery to the infected lung. Methods: MSC-CM from bone marrow (BM) and umbilical cord (UC) MSCs were passed through the commercially available Aerogen Solo nebulizer. Known colony forming units of Escherichia coli, Staphylococcus aureus, and multidrug resistant Klebsiella pneumoniae clinical isolates were added to MSC-CM in an orbital shaker and antibacterial capacity assessed through OD600 spectrophotometry. To exclude the possible effects of medium depletion on bacteria proliferation, MSC-CM was concentrated with a 3000 Da cutoff filter, diluted with fresh media, and retested against inoculum. Enzyme-linked immunosorbent assay was used to quantify levels of antimicrobial peptides (AMPs) and IL-8 present at pre- and postnebulization. Results: Both BM and UC MSC-CM inhibited proliferation of all pathogens, and this ability was retained after nebulization. Concentrating and reconstituting CM did not affect antibacterial properties. Interestingly, LL-37 protein did not appear to survive nebulization, although other secreted AMPs and an unrelated protein, IL-8, were largely intact. Conclusion: MSC-CM is a potent antimicrobial agent and is compatible with vibrating mesh nebulization delivery. The mechanism is through a secreted factor that is over 3000 Da in size, although it does not appear to rely solely on previously identified peptides such as LL-37, hepcidin, or lipocalin-2.
Collapse
Affiliation(s)
- Sean D McCarthy
- Anaesthesia, School of Medicine, National University of Ireland Galway, Galway, Ireland.,Regenerative Medicine Institute (REMEDI) at CÚRAM Centre for Research in Medical Devices, National University of Ireland Galway, Galway, Ireland
| | - Elizabeth Horgan
- Microbiology, School of Natural Sciences, National University of Ireland Galway, Galway, Ireland
| | - Areeba Ali
- Microbiology, School of Natural Sciences, National University of Ireland Galway, Galway, Ireland
| | - Claire Masterson
- Anaesthesia, School of Medicine, National University of Ireland Galway, Galway, Ireland.,Regenerative Medicine Institute (REMEDI) at CÚRAM Centre for Research in Medical Devices, National University of Ireland Galway, Galway, Ireland
| | - John G Laffey
- Anaesthesia, School of Medicine, National University of Ireland Galway, Galway, Ireland.,Regenerative Medicine Institute (REMEDI) at CÚRAM Centre for Research in Medical Devices, National University of Ireland Galway, Galway, Ireland
| | - Ronan MacLoughlin
- Regenerative Medicine Institute (REMEDI) at CÚRAM Centre for Research in Medical Devices, National University of Ireland Galway, Galway, Ireland.,Aerogen Ltd., Dangan, Galway.,School of Pharmacy, Royal College of Surgeons, Dublin, Ireland.,School of Pharmacy and Pharmaceutical Sciences, Trinity College, Dublin, Ireland
| | - Daniel O'Toole
- Anaesthesia, School of Medicine, National University of Ireland Galway, Galway, Ireland.,Regenerative Medicine Institute (REMEDI) at CÚRAM Centre for Research in Medical Devices, National University of Ireland Galway, Galway, Ireland
| |
Collapse
|
21
|
Li J, Zhao M, Hadeer M, Luo J, Fink JB. Dose Response to Transnasal Pulmonary Administration of Bronchodilator Aerosols via Nasal High-Flow Therapy in Adults with Stable Chronic Obstructive Pulmonary Disease and Asthma. Respiration 2019; 98:401-409. [PMID: 31473748 DOI: 10.1159/000501564] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2019] [Accepted: 06/17/2019] [Indexed: 02/05/2023] Open
Abstract
BACKGROUND There has been increasing interest in transnasal pulmonary aerosol administration, but the dose-response relationship has not been reported. OBJECTIVES To determine the accumulative bronchodilator dose at which patients with stable mild-to-moderate asthma and chronic obstructive pulmonary disease (COPD) achieve similar spirometry responses before and after bronchodilator tests using albuterol via a metered dose inhaler with a valved holding chamber (MDI + VHC). METHOD Adult patients who met ATS/ERS criteria for bronchodilator responses in pulmonary function laboratory were recruited and consented to participate. After a washout period, patients received escalating doubling dosages (0.5, 1, 2, and 4 mg) of albuterol in a total volume of 2 mL delivered by vibrating mesh nebulizer via a nasal cannula at 37°C with a flow rate of 15-20 L/min using a Venturi air entrainment device. Spirometry was measured at baseline and after each dose. Titration was stopped when an additional forced expiratory volume in 1 second (FEV1) improvement was <5%. RESULTS 42 patients (16 males) with stable mild-to-moderate asthma (n = 29) and COPD (n = 13) were enrolled. FEV1 increment after a cumulative dose of 1.5 mg of albuterol via nasal cannula at 15-20 L/min was similar to 4 actuations of MDI + VHC (0.34 ± 0.18 vs. 0.34 ± 0.12 L, p = 0.878). Using ATS/ERS criteria of the bronchodilator test, 33.3% (14/42) and 69% (29/42) of patients responded to 0.5 and 1.5 mg of albuterol, respectively. CONCLUSIONS With a nasal cannula at 15-20 L/min, transnasal pulmonary delivery of 1.5 mg albuterol resulted in similar bronchodilator response as 4 actuations of MDI + VHC.
Collapse
Affiliation(s)
- Jie Li
- Division of Respiratory Care, Department of Cardiopulmonary Sciences, Rush University Medical Center, Chicago, Illinois, USA,
| | - Minghua Zhao
- Division of Pulmonary Function Test Laboratory, Department of Respiratory Care, People's Hospital of the Xinjiang Autonomous Region, Urumqi, China
| | - Maierbati Hadeer
- Division of Pulmonary Function Test Laboratory, Department of Respiratory Care, People's Hospital of the Xinjiang Autonomous Region, Urumqi, China
| | - Jian Luo
- Department of Respiratory and Critical Care Medicine, West China School of Medicine and West China Hospital, Sichuan University, Chengdu, China
| | - James B Fink
- Division of Respiratory Care, Department of Cardiopulmonary Sciences, Rush University Medical Center, Chicago, Illinois, USA.,Aerogen Pharma Corporation, San Mateo, California, USA
| |
Collapse
|
22
|
Spence BM, Longest W, Wei X, Dhapare S, Hindle M. Development of a High-Flow Nasal Cannula and Pharmaceutical Aerosol Combination Device. J Aerosol Med Pulm Drug Deliv 2019; 32:224-241. [PMID: 30855199 PMCID: PMC6685196 DOI: 10.1089/jamp.2018.1488] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2018] [Accepted: 01/04/2019] [Indexed: 11/12/2022] Open
Abstract
Background: Aerosol drug delivery to the lungs is known to be very inefficient during all forms of noninvasive ventilation, especially when the aerosol is administered simultaneously with high-flow nasal cannula (HFNC) therapy. The objective of this study was to develop a new combination device based on vibrating mesh nebulizers that can provide continuously heated and humidified HFNC therapy as well as on-demand pharmaceutical aerosols with high efficiency. Methods: The combination device implemented separate mesh nebulizers for generating humidity (humidity nebulizer) and delivering the medical aerosol (drug nebulizer). Nebulizers were actuated in an alternating manner with the drug nebulizer delivering the medication during a portion of an adult inhalation cycle. Aerosol entered a small-volume mixing region where it was combined with ventilation gas flow and then entered a heating channel to produce small particles that are desirable for nose-to-lung administration and potentially excipient enhanced growth delivery. Three assessment methods (analytical calculations, computational fluid dynamics [CFD] simulations, and in vitro experiments in three-dimensional [3D] printed devices) were used to improve the mixer-heater design to minimize depositional drug losses, maintain a small device volume, ensure sufficient droplet evaporation, and control the outlet thermodynamic conditions. Results: For an initial configuration (Design 1), good agreement in performance metrics was found using the three assessment methods. Based on insights gained from the CFD simulations of Design 1, two new designs were developed and produced with 3D printing. Experimental analysis indicated that the new designs both achieved <5% depositional loss in the mixer-heater even with cyclic operation and sufficiently dried the aerosol from an initial size of 5.3 μm to an outlet size of ∼1.0 μm. A combination of the applied methods indicated that the desired thermodynamic conditions of HFNC therapy were also met. Conclusions: Multiple methodological approaches were used concurrently to develop a new combination device for administering HFNC therapy and simultaneous on-demand pharmaceutical aerosols to the lungs with high efficiency. The use of a small-volume mixer-heater (<100 mL), synchronization of the drug nebulizer with inhalation, and small outlet particle size should enable high efficiency lung delivery of the aerosol.
Collapse
Affiliation(s)
- Benjamin M. Spence
- Department of Mechanical and Nuclear Engineering, Virginia Commonwealth University, Richmond, Virginia
| | - Worth Longest
- Department of Mechanical and Nuclear Engineering, Virginia Commonwealth University, Richmond, Virginia
- Department of Pharmaceutics, Virginia Commonwealth University, Richmond, Virginia
| | - Xiangyin Wei
- Department of Pharmaceutics, Virginia Commonwealth University, Richmond, Virginia
| | - Sneha Dhapare
- Department of Pharmaceutics, Virginia Commonwealth University, Richmond, Virginia
| | - Michael Hindle
- Department of Pharmaceutics, Virginia Commonwealth University, Richmond, Virginia
| |
Collapse
|
23
|
Corcoran TE, Saville A, Adams PS, Johnston DJ, Czachowski MR, Domnina YA, Lin JH, Weiner DJ, Huber AS, Sanchez De Toledo J, Lo CW. Deposition studies of aerosol delivery by nasal cannula to infants. Pediatr Pulmonol 2019; 54:1319-1325. [PMID: 30932345 DOI: 10.1002/ppul.24326] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/14/2018] [Revised: 03/05/2019] [Accepted: 03/12/2019] [Indexed: 12/25/2022]
Abstract
AIM Nasal cannulas are used to provide oxygen support for infants and have been considered as a means for delivering aerosols to the lungs. To measure mucociliary clearance in the lungs of infants with congenital heart defects, we delivered radiopharmaceutical aerosols via a nasal cannula. Here we report on the pulmonary and nasal deposition of these aerosols. METHOD A total of 18 infants (median age = 26 days; quartiles = 11-74 days) performed clearance measurements soon before or after corrective cardiac surgery. The regional aerosol deposition was assessed using gamma camera imaging. RESULTS Cannula flow rate significantly affected pulmonary dosing. Flow rates useful for oxygen support were associated with low pulmonary deposition (2 L/min; mean, 4.5% of deposited dose; range, 2%-9%; n = 7) and high nasal deposition. Much lower cannula flow rates increased the pulmonary deposition (0.2 L/min; mean, 33.5% of deposited dose; range, 15%-51%; n = 5; P = 0.005 vs 2 L/min). The ratio of nose/lung dosing was approximately 26:1 at 2 L/min and 2:1 at 0.2 L/min. Bench studies demonstrated cannula output rates of 10.2 ± 1.7% (2 L/min) and 3.3 ± 0.4% (0.2 L/min) of the loaded nebulizer dose during a 2-minute delivery. Combining in vitro and in vivo results, we estimate that 0.46% of the loaded nebulizer dose reaches the lungs at 2 L/min vs 1.10% at 0.2 L/min during a 2-minute delivery. CONCLUSION With the delivery system used here, pulmonary aerosol delivery via nasal cannula was very inefficient at the flow rates required to provide oxygen support. Even at low flows, nasal deposition was substantial and local toxicity must be considered.
Collapse
Affiliation(s)
- Timothy E Corcoran
- Division of Pulmonary, Allergy, and Critical Care Medicine, University of Pittsburgh, Pittsburgh, Pennsylvania.,Chemical and Petroleum Engineering Department, University of Pittsburgh, Pittsburgh, Pennsylvania.,Department of Bioengineering, University of Pittsburgh, Pittsburgh, Pennsylvania
| | - Al Saville
- Respiratory Department, Children's Hospital of Pittsburgh, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania
| | - Phillip S Adams
- Department of Anesthesiology and Perioperative Medicine, University of Pittsburgh, Pittsburgh, Pennsylvania
| | - Darragh J Johnston
- Chemical and Petroleum Engineering Department, University of Pittsburgh, Pittsburgh, Pennsylvania
| | - Michael R Czachowski
- Nuclear Medicine Department, Children's Hospital of Pittsburgh, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania
| | - Yuliya A Domnina
- Department of Critical Care Medicine, University of Pittsburgh, Pittsburgh, Pennsylvania
| | - Jiuann-Huey Lin
- Department of Critical Care Medicine, University of Pittsburgh, Pittsburgh, Pennsylvania
| | - Daniel J Weiner
- Pediatric Pulmonary Medicine, Allergy, and Immunology, University of Pittsburgh, Pittsburgh, Pennsylvania
| | - Alex S Huber
- Chemical and Petroleum Engineering Department, University of Pittsburgh, Pittsburgh, Pennsylvania
| | - Joan Sanchez De Toledo
- Department of Critical Care Medicine, University of Pittsburgh, Pittsburgh, Pennsylvania
| | - Cecilia W Lo
- Department of Developmental Biology, University of Pittsburgh, Pittsburgh, Pennsylvania
| |
Collapse
|
24
|
Alcoforado L, Ari A, Barcelar JDM, Brandão SCS, Fink JB, de Andrade AD. Impact of Gas Flow and Humidity on Trans-Nasal Aerosol Deposition via Nasal Cannula in Adults: A Randomized Cross-Over Study. Pharmaceutics 2019; 11:pharmaceutics11070320. [PMID: 31284680 PMCID: PMC6680424 DOI: 10.3390/pharmaceutics11070320] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2019] [Revised: 07/04/2019] [Accepted: 07/04/2019] [Indexed: 11/16/2022] Open
Abstract
Background: Trans-nasal pulmonary aerosol delivery using high flow nasal cannula (HFNC) devices is described with the administration of high gas flows exceeding patient inspiratory flow (HF) and with lower flows (LF). The aim of this pilot clinical trial was to compare deposition and distribution of radiolabeled aerosol via nasal cannula in healthy adults across three rates of gas flow delivered with active heated humidification, and to further identify the impact of aerosol administration without heated humidity. Methods: Twenty-three (23) healthy adults (16F) were randomized to receive aerosol with active heated humidification or unheated oxygen at gas flows of 10 L/min (n = 8), 30 L/min (n = 7), or 50 L/min (n = 8). Diethylenetriaminepentaacetic acid labeled with 1 millicurie (37 MBq) of Technetium-99m (DTPA-Tc99m) was mixed with NaCl to a fill volume of 1 mL, and administered via mesh nebulizer placed at the inlet of the humidifier. Radioactivity counts were performed using a gamma camera and the regions of interest (ROIs) were delimited with counts from the lungs, upper airways, stomach, nebulizer, circuit, and expiratory filter. A mass balance was calculated and each compartment was expressed as a percentage of the total. Results: Lung deposition (mean ± SD) with heated humidified gas was greater at 10 L/min than 30 L/min or 50 L/min (17.2 ± 6.8%, 5.71 ± 2.04%, and 3.46 ± 1.24%, respectively; p = 0.0001). Using unheated carrier gas, a lung dose of aerosol was similar to the active heated humidification condition at 10 L/min, but greater at 30 and 50 L/min (p = 0.011). Administered gas flow and lung deposition were negatively correlated (r = −0.880, p < 0.001). Conclusions: Both flow and active heated humidity inversely impact aerosol delivery through HFNC. Nevertheless, aerosol administration across the range of commonly used flows can provide measurable levels of lung deposition in healthy adult subjects (NCT 02519465).
Collapse
Affiliation(s)
- Luciana Alcoforado
- Department of Physical Therapy, Universidade Federal de Pernambuco, Recife 50740-560, PE, Brazil
| | - Arzu Ari
- Department of Respiratory Therapy, Texas State University, Round Rock, TX 78665, USA
| | | | | | - James B Fink
- Department of Respiratory Therapy, Texas State University, Round Rock, TX 78665, USA
- Aerogen Pharma Corp, San Mateo, CA 94402, USA
| | - Armele Dornelas de Andrade
- Department of Physical Therapy, Universidade Federal de Pernambuco, Recife 50740-560, PE, Brazil.
- Avenida Jornalista Aníbal Fernandes, SN-Cidade Universitária, CEP, Recife 50740-560, PE, Brazil.
| |
Collapse
|
25
|
Li J, Luo J, Chen Y, Xie L, Fink JB. Effects of flow rate on transnasal pulmonary aerosol delivery of bronchodilators via high-flow nasal cannula for patients with COPD and asthma: protocol for a randomised controlled trial. BMJ Open 2019; 9:e028584. [PMID: 31239304 PMCID: PMC6597746 DOI: 10.1136/bmjopen-2018-028584] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/05/2023] Open
Abstract
INTRODUCTION Both in vitro and in vivo radiolabelled studies on nebulisation via high-flow nasal cannula showed that inhaled dose decreases as the administered gas flow increases. In our previous in vitro study, we investigated the effects of the ratio of gas flow to subject's peak inspiratory flow (GF:IF) on the aerosol deposition, which increased as the GF:IF decreased, with an optimal GF:IF between 0.1 and 0.5 producing a stable 'lung' deposition in both quiet and distressed breathing. Thus, we aim to validate our in vitro findings in subjects with reversible airflow limitations by assessing their response to inhaled bronchodilator. METHODS AND ANALYSIS This is a single-centre, randomised controlled trial. Subjects with chronic obstructive pulmonary disease or asthma with positive response to 400μg albuterol via metered dose inhaler and valved holding chamber will be enrolled and consented. After a washout period (1-3 days), subjects will be randomly assigned to inhale albuterol with one of three gas flows: 50 L/min, GF:IF=1.0 and GF:IF=0.5. In each arm, subjects will inhale 2 mL saline, followed by escalating doubling doses (0.5, 1, 2 and 4 mg) of albuterol in a fill volume of 2 mL, delivered by a vibrating mesh nebuliser via heated nasal cannula set up at 37°C. An interval of 30 min between each dose of albuterol, with spirometry measured at baseline and after each inhalation. Titration will be terminated if forced expiratory volume in 1 s improvement is <5%, or adverse event is observed. ETHICS AND DISSEMINATION This trial has been approved by the Ethic Committee of People's Liberation Army General Hospital, Beijing, China (no. S2018-200-01). The results will be disseminated through peer-reviewed journals, national and international conferences. TRIAL REGISTRATION NUMBER NCT03739359; Pre-results.
Collapse
Affiliation(s)
- Jie Li
- Department of Cardiopulmonary Sciences, Division of Respiratory Care, Rush University, Chicago, Illinois, USA
| | - Jian Luo
- Department of Pulmonary and Critical Care Medicine, Sichuan University West China Hospital, Chengdu, China
| | - Yibing Chen
- Department of Respiratory and Critical Care Medicine, Pulmonary Function Test Lab, General Hospital of People’s Liberation Army, Beijing, China
| | - Lixing Xie
- Department of Respiratory and Critical Care Medicine, Pulmonary Function Test Lab, General Hospital of People’s Liberation Army, Beijing, China
| | - James B Fink
- Department of Cardiopulmonary Sciences, Division of Respiratory Care, Rush University, Chicago, Illinois, USA
- Aerogen Pharma Corp, San Mateo, California, USA
| |
Collapse
|
26
|
Li J, Harnois LJ, Markos B, Roberts KM, Homoud SA, Liu J, Mirza S, Vines D. Epoprostenol Delivered via High Flow Nasal Cannula for ICU Subjects with Severe Hypoxemia Comorbid with Pulmonary Hypertension or Right Heart Dysfunction. Pharmaceutics 2019; 11:pharmaceutics11060281. [PMID: 31207936 PMCID: PMC6631264 DOI: 10.3390/pharmaceutics11060281] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2019] [Revised: 06/06/2019] [Accepted: 06/10/2019] [Indexed: 12/20/2022] Open
Abstract
Inhaled epoprostenol (iEPO) has been utilized to improve oxygenation in mechanically ventilated subjects with severe hypoxemia, but the evidence for iEPO via high-flow nasal cannula (HFNC) is rare. Following approval by the institutional review board, this retrospective cohort study evaluated subjects who received iEPO via HFNC for more than 30 min to treat severe hypoxemia comorbid with pulmonary hypertension or right heart dysfunction between July 2015 and April 2018. A total of 11 subjects were enrolled in the study of whom 4 were male (36.4%), age 57.5 ± 22.1 years, and APACHE II score at ICU admission was 18.5 ± 5.7. Ten subjects had more than three chronic heart or lung comorbidities; seven of them used home oxygen. After inhaling epoprostenol, subjects' SpO2/FIO2 ratio improved from 107.5 ± 26.3 to 125.5 ± 31.6 (p = 0.026) within 30-60 min. Five subjects (45.5%) had SpO2/FIO2 improvement >20%, which was considered as a positive response. Heart rate, blood pressure, and respiratory rate were not significantly different. Seven subjects did not require intubation, and seven subjects were discharged home. This retrospective study demonstrated the feasibility of iEPO via HFNC in improving oxygenation. Careful titration of flow while evaluating subjects' response may help identify responders and avoid delaying other interventions. This study supports the need for a larger prospective randomized control trial to further evaluate the efficacy of iEPO via HFNC in improving outcomes.
Collapse
Affiliation(s)
- Jie Li
- Department of Cardiopulmonary Sciences, Division of Respiratory Care, Rush University Medical Center, Chicago, IL 60130, USA.
| | - Lauren J Harnois
- Department of Cardiopulmonary Sciences, Division of Respiratory Care, Rush University Medical Center, Chicago, IL 60130, USA.
| | - Bethelhem Markos
- Department of Cardiopulmonary Sciences, Division of Respiratory Care, Rush University Medical Center, Chicago, IL 60130, USA.
| | - Keith M Roberts
- Department of Cardiopulmonary Sciences, Division of Respiratory Care, Rush University Medical Center, Chicago, IL 60130, USA.
| | - Salma Al Homoud
- Department of Cardiopulmonary Sciences, Division of Respiratory Care, Rush University Medical Center, Chicago, IL 60130, USA.
| | - Jing Liu
- Department of Cardiopulmonary Sciences, Division of Respiratory Care, Rush University Medical Center, Chicago, IL 60130, USA.
| | - Sara Mirza
- Department of Cardiopulmonary Sciences, Division of Respiratory Care, Rush University Medical Center, Chicago, IL 60130, USA.
| | - David Vines
- Department of Cardiopulmonary Sciences, Division of Respiratory Care, Rush University Medical Center, Chicago, IL 60130, USA.
| |
Collapse
|
27
|
The Ratio of Nasal Cannula Gas Flow to Patient Inspiratory Flow on Trans-nasal Pulmonary Aerosol Delivery for Adults: An in Vitro Study. Pharmaceutics 2019; 11:pharmaceutics11050225. [PMID: 31083346 PMCID: PMC6571744 DOI: 10.3390/pharmaceutics11050225] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2019] [Revised: 05/08/2019] [Accepted: 05/08/2019] [Indexed: 11/17/2022] Open
Abstract
Trans-nasal aerosol deposition during distressed breathing is higher than quiet breathing, and decreases as administered gas flow increases. We hypothesize that inhaled dose is related to the ratio of gas flow to patient inspiratory flow (GF:IF). An adult manikin (Laerdal) with a collecting filter placed at trachea was connected to a dual-chamber model lung, which was driven by a ventilator to simulate quiet and distressed breathing with different inspiratory flows. Gas flow was set at 5, 10, 20, 40 and 60 L/min. Albuterol (2.5mg in 1 mL) was nebulized by vibrating mesh nebulizer at the inlet of humidifier at 37 °C for each condition (n = 3). Drug was eluted from the filter and assayed with UV spectrophotometry (276 nm). GF:IF was the primary predictor of inhaled dose (p < 0.001). When the ratio was < 1.0, the inhaled dose was higher than ratio > 1.0 (21.8 ± 3.8% vs. 9.0 ± 3.7%, p < 0.001), and the inhaled dose was similar between quiet and distressed breathing (22.3 ± 5.0% vs. 21.3 ± 2.7%, p = 0.379). During trans-nasal aerosol delivery, GF:IF primarily affected the inhaled dose. Compared to the ratio above 1.0, the ratio below 1.0 produced a higher and more-consistent inhaled dose.
Collapse
|
28
|
Valencia-Ramos J, Arnaez J, Benito JM, Mirás A, Ochoa C, Beltrán S. A comparative in vitro study of standard facemask jet nebulization and high-flow nebulization in bronchiolitis. Exp Lung Res 2019; 45:13-21. [PMID: 31007091 DOI: 10.1080/01902148.2019.1599084] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
Aim of Study: The use of a nebulizer paired with high-flow nasal cannulas (HFNC) has been proposed for drug delivery in bronchiolitis. Particle size nebulized is a relevant factor determining the efficacy of the nebulization. We replicated in vitro the theoretical parameters most widely used in bronchiolitis and we compared the size of the droplet nebulized with a standard nebulizer and a nebulizer integrated into HFNC. Materials and Methods: We used laser diffraction to analyze the particle size nebulized (volume median diameter Dv50). The standard system was a jet nebulizer connected to a facemask with a flow rate of 8 L/min (JN). Three designs were used as nebulizers integrated into HFNC: a vibrating mesh nebulizer set 1) before (HFNC-BH) and 2) after (HFNC-AH) the humidifier, and 3) a jet nebulizer connected before the nasal cannula (HFNC-BNC). HFNC was used with neonatal (3-8 L/min) and infant cannulas (8-15 L/min). Results: Droplet size was similar among the three drugs studied. A lower particle size was obtained when using the nebulization system integrated into HFNC compared to the standard nebulizer, regardless of the flow rate and the nasal cannula used when the position of the nebulizer was before the nasal cannula (p < 0.05): 6.89 µm (JN), 2.49 µm (HFNC-BNC 3 L/min), 2.59 µm (HFNC-BNC 5 L/min), 2.44 µm (HFNC-BNC 8 L/min), 3.22 µm (HFNC-BNC 10 L/min), 3.23 µm (HFNC-BNC 13 L/min), 3.16 µm (HFNC-BNC 15 L/min). The particle size was lower in HFNC-BF compared to the HFNC-AH using neonatal nasal cannula (3-8 L/min) (p < 0.05). Conclusion: The use of a nebulizer integrated with HFNC has shown promising results in an experimental scenario of bronchiolitis. The particle size achieved with the nebulizer placed before the humidifier is equivalent to the one obtained via conventional nebulization, and it is even smaller when the integrated nebulizer is placed before the nasal cannulas.
Collapse
Affiliation(s)
- Juan Valencia-Ramos
- a Paediatric Intensive Care Unit , Hospital Universitario de Burgos , Burgos , Spain
| | - Juan Arnaez
- b Department of Neonatology , Hospital Universitario de Burgos , Burgos , Spain
| | - José Manuel Benito
- c Chemical Engineering Division, Department of Biotechnology and Food Science , Universidad de Burgos , Burgos , Spain
| | - Alicia Mirás
- a Paediatric Intensive Care Unit , Hospital Universitario de Burgos , Burgos , Spain
| | - Carlos Ochoa
- d Department of Investigation Unit , Hospital Virgen de la Concha, Escuela Universitaria de Enfermería de Zamora , Zamora , Spain
| | - Sagrario Beltrán
- c Chemical Engineering Division, Department of Biotechnology and Food Science , Universidad de Burgos , Burgos , Spain
| |
Collapse
|
29
|
Chang KH, Moon SH, Oh JY, Yoon YS, Gu N, Lim CY, Park BJ, Nam KC. Comparison of Salbutamol Delivery Efficiency for Jet versus Mesh Nebulizer Using Mice. Pharmaceutics 2019; 11:pharmaceutics11040192. [PMID: 31010218 PMCID: PMC6523426 DOI: 10.3390/pharmaceutics11040192] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2019] [Revised: 04/11/2019] [Accepted: 04/17/2019] [Indexed: 11/16/2022] Open
Abstract
Recent reports using a breathing simulator system have suggested that mesh nebulizers provide more effective medication delivery than jet nebulizers. In this study, the performances of jet and mesh nebulizers were evaluated by comparing their aerosol drug delivery efficiencies in mice. We compared four home nebulizers: two jet nebulizers (PARI BOY SX with red and blue nozzles), a static mesh nebulizer (NE-U22), and a vibrating mesh nebulizer (NE-SM1). After mice were exposed to salbutamol aerosol, the levels of salbutamol in serum and lung were estimated by ELISA. The residual volume of salbutamol was the largest at 34.6% in PARI BOY SX, while the values for NE-U22 and NE-SM1 mesh nebulizers were each less than 1%. The salbutamol delivery efficiencies of NE-U22 and NE-SM1 were higher than that of PARI BOY SX, as the total delivered amounts of lung and serum were 39.9% and 141.7% as compared to PARI BOY SX, respectively. The delivery efficiency of the mesh nebulizer was better than that of the jet nebulizer. Although the jet nebulizer can generate smaller aerosol particles than the mesh nebulizer used in this study, the output rate of the jet nebulizer is low, resulting in lower salbutamol delivery efficiency. Therefore, clinical validation of the drug delivery efficiency according to nebulizer type is necessary to avoid overdose and reduced drug wastage.
Collapse
Affiliation(s)
- Kyung Hwa Chang
- Department of Medical Engineering, Dongguk University College of Medicine, Goyang-si, Gyeonggi-do 10326, Korea.
| | - Sang-Hyub Moon
- Department of Medical Engineering, Dongguk University College of Medicine, Goyang-si, Gyeonggi-do 10326, Korea.
| | - Jin Young Oh
- Department of Internal Medicine, Dongguk University Ilsan Hospital, Goyang-si, Gyeonggi-do 10326, Korea.
| | - Young-Soon Yoon
- Department of Internal Medicine, Dongguk University Ilsan Hospital, Goyang-si, Gyeonggi-do 10326, Korea.
| | - Namyi Gu
- Department of Clinical Pharmacology and Therapeutics, Dongguk University Ilsan Hospital, Goyang-si, Gyeonggi-do 10326, Korea.
| | - Chi-Yeon Lim
- Department of Biostatistics, Dongguk University College of Medicine, Goyang-si, Gyeonggi-do 10326, Korea.
| | - Bong Joo Park
- Department of Electrical Biological Physics and Institute of Biomaterials, Kwangwoon University, Seoul 01897, Korea.
| | - Ki Chang Nam
- Department of Medical Engineering, Dongguk University College of Medicine, Goyang-si, Gyeonggi-do 10326, Korea.
| |
Collapse
|
30
|
Bennett G, Joyce M, Fernández EF, MacLoughlin R. Comparison of aerosol delivery across combinations of drug delivery interfaces with and without concurrent high-flow nasal therapy. Intensive Care Med Exp 2019; 7:20. [PMID: 30945044 PMCID: PMC6447636 DOI: 10.1186/s40635-019-0245-2] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2018] [Accepted: 03/25/2019] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Current clinical practice during high-flow nasal therapy (HFNT) involves utilization of a nasal cannula to provide humidification, with a facemask placed over the cannula to deliver aerosol. Few studies have compared aerosol delivery across various delivery interfaces during HFNT. The objective of this study was to address this gap in the literature and evaluate aerosol delivery using two nebulizer types across different drug delivery interfaces, nasal cannula, facemask, and mouthpiece, during simulated adult HFNT. METHODS A facemask or mouthpiece and/or a nasal cannula were positioned on an anatomically correct adult head model. The head model was connected to a breathing simulator via a collection filter. Both healthy breathing pattern and distressed breathing patterns were utilized. Aerosol dose was determined by quantifying the mass of drug captured on a filter positioned distal to the trachea. RESULTS During simulated healthy breathing, a significantly greater aerosol dose was observed when the vibrating mesh nebulizer (VMN) was integrated with HFNT alone, supplying aerosol and humidified air simultaneously (2.88 ± 0.15%), as opposed to using with a facemask (0.33 ± 0.07%, 1.62 ± 0.46%, and 1.07 ± 0.25% at 0 L/min (LPM), 2LPM, and 6LPM, respectively) or mouthpiece (0.56 ± 0.13%, 2.16 ± 0.06%, and 1.82 ± 0.41% at 0LPM, 2LPM, and 6LPM). In addition, aerosol delivery was also significantly greater when the VMN was integrated into simulated HFNT (2.88 ± 0.15%), in comparison with using the jet nebulizer (JN) with a facemask (0.82 ± 0.16%) or a mouthpiece (0.86 ± 0.11%). During simulated distressed breathing, a significantly greater aerosol dose was observed when the VMN was integrated with HFNT, supplying aerosol and humidified air simultaneously (6.81 ± 0.45%), compared with using a facemask (0.86 ± 0.04%, 2.96 ± 0.26%, and 4.23 ± 0.93% at 0LPM, 2LPM, and 6LPM) or mouthpiece (0.73 ± 0.37%, 0.97 ± 0.20%, and 3.11 ± 0.53% at 0LPM, 2LPM, and 6LPM, respectively). Aerosol delivery was also greater when the VMN was integrated into HFNT (6.81 ± 0.45%), in comparison with using the JN with a facemask (5.72 ± 0.71%) or a mouthpiece (0.69 ± 0.53%). Furthermore, across all drug delivery interfaces, and in line with previous reports, aerosol delivery was greater during simulated distressed breathing, in comparison with simulated healthy adult breathing. CONCLUSIONS This article will be of considerable benefit in enhancing the understanding of aerosol delivery during HFNT, an increasingly adopted therapeutic intervention by healthcare professionals.
Collapse
Affiliation(s)
- Gavin Bennett
- Aerogen Limited, IDA Business Park, Dangan, Galway, Ireland
| | - Mary Joyce
- Aerogen Limited, IDA Business Park, Dangan, Galway, Ireland
| | | | | |
Collapse
|
31
|
Kwok PCL, Wallin M, Dolovich MB, Chan HK. Studies of Radioaerosol Deposition in the Respiratory Tract. Semin Nucl Med 2019; 49:62-70. [PMID: 30545519 DOI: 10.1053/j.semnuclmed.2018.10.014] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Deposition of aerosols in the respiratory tract can be quantitatively and qualitatively studied by scintigraphy. The most commonly used radionuclide for this purpose is technetium-99m. The effects of various factors on particle deposition have been investigated by using radiolabeled aerosols in the past decade. Most of these studies were in vivo but some were in vitro or ex vivo. The factors examined include particle size, formulation, inhaler design, inhalation flowrate, body posture, and gravity. They have been shown to influence pulmonary deposition, nasal high flow nebulization, and intranasal delivery. A thorough understanding of the various factors is required for the advancement of respiratory-drug delivery. Scintigraphy is a powerful technique that can assist in this regard.
Collapse
Affiliation(s)
- Philip Chi Lip Kwok
- Sydney Pharmacy School, Faculty of Medicine and Health, The University of Sydney, Camperdown, New South Wales, Australia
| | - Martin Wallin
- Sydney Pharmacy School, Faculty of Medicine and Health, The University of Sydney, Camperdown, New South Wales, Australia
| | - Myrna B Dolovich
- Department of Medicine, McMaster University, Hamilton, ON, Canada.
| | - Hak-Kim Chan
- Sydney Pharmacy School, Faculty of Medicine and Health, The University of Sydney, Camperdown, New South Wales, Australia
| |
Collapse
|
32
|
Wallin M, Tang P, Chang RYK, Yang M, Finlay WH, Chan HK. Aerosol drug delivery to the lungs during nasal high flow therapy: an in vitro study. BMC Pulm Med 2019; 19:42. [PMID: 30767769 PMCID: PMC6376697 DOI: 10.1186/s12890-019-0807-9] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2018] [Accepted: 02/06/2019] [Indexed: 01/23/2023] Open
Abstract
Background Aerosol delivery through a nasal high flow (NHF) system is attractive for clinicians as it allows for simultaneous administration of oxygen and inhalable drugs. However, delivering a fine particle fraction (FPF, particle wt. fraction < 5.0 μm) of drugs into the lungs has been very challenging, with highest value of only 8%. Here, we aim to develop an efficient nose-to-lung delivery system capable of delivering improved quantities (FPF > 16%) of dry powder aerosols to the lungs via an NHF system. Methods We evaluated the FPF of spray-dried mannitol with leucine with a next generation impactor connected to a nasopharyngeal outlet of an adult nasal airway replica. In addition, we investigated the influence of different dispersion (20–30 L/min) and inspiratory (20–40 L/min) flow rates, on FPF. Results We found an FPF of 32% with dispersion flow rate at 25 L/min and inspiratory flow rate at 40 L/min. The lowest FPF (21%) obtained was at the dispersion flow rate at 30 L/min and inspiratory flow rate at 30 L/min. A higher inspiratory flow rate was generally associated with a higher FPF. The nasal cannula accounted for most loss of aerosols. Conclusions In conclusion, delivering a third of inhalable powder to the lungs is possible in vitro through an NHF system using a low dispersion airflow and a highly dispersible powder. Our results may lay the foundation for clinical evaluation of powder aerosol delivery to the lungs during NHF therapy in humans.
Collapse
Affiliation(s)
- Martin Wallin
- Advanced Drug Delivery Group, School of Pharmacy, The University of Sydney Faculty of Medicine and Health, Sydney, NSW, 2006, Australia.,Department of Pharmacy, University of Copenhagen, Universitetsparken 2, DK-2100, Copenhagen, Denmark
| | - Patricia Tang
- Advanced Drug Delivery Group, School of Pharmacy, The University of Sydney Faculty of Medicine and Health, Sydney, NSW, 2006, Australia
| | - Rachel Yoon Kyung Chang
- Advanced Drug Delivery Group, School of Pharmacy, The University of Sydney Faculty of Medicine and Health, Sydney, NSW, 2006, Australia
| | - Mingshi Yang
- Department of Pharmacy, University of Copenhagen, Universitetsparken 2, DK-2100, Copenhagen, Denmark
| | - Warren H Finlay
- Department of Mechanical Engineering, University of Alberta, Edmonton, T6G1H9, Canada
| | - Hak-Kim Chan
- Advanced Drug Delivery Group, School of Pharmacy, The University of Sydney Faculty of Medicine and Health, Sydney, NSW, 2006, Australia.
| |
Collapse
|
33
|
Reminiac F, Vecellio L, Bodet-Contentin L, Gissot V, Le Pennec D, Salmon Gandonnière C, Cabrera M, Dequin PF, Plantier L, Ehrmann S. Nasal high-flow bronchodilator nebulization: a randomized cross-over study. Ann Intensive Care 2018; 8:128. [PMID: 30570679 PMCID: PMC6301902 DOI: 10.1186/s13613-018-0473-8] [Citation(s) in RCA: 37] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2018] [Accepted: 12/11/2018] [Indexed: 01/14/2023] Open
Abstract
Background There is an absence of controlled clinical data showing bronchodilation effectiveness after nebulization via nasal high-flow therapy circuits. Results Twenty-five patients with reversible airflow obstruction received, in a randomized order: (1) 2.5 mg albuterol delivered via a jet nebulizer with a facial mask; (2) 2.5 mg albuterol delivered via a vibrating mesh nebulizer placed downstream of a nasal high-flow humidification chamber (30 L/min and 37 °C); and (3) nasal high-flow therapy without nebulization. All three conditions induced significant individual increases in forced expiratory volume in one second (FEV1) compared to baseline. The median change was similar after facial mask nebulization [+ 350 mL (+ 180; + 550); + 18% (+ 8; + 30)] and nasal high flow with nebulization [+ 330 mL (+ 140; + 390); + 16% (+ 5; + 24)], p = 0.11. However, it was significantly lower after nasal high-flow therapy without nebulization [+ 50 mL (− 10; + 220); + 3% (− 1; + 8)], p = 0.0009. FEV1 increases after facial mask and nasal high-flow nebulization as well as residual volume decreases were well correlated (p < 0.0001 and p = 0.01). Both techniques showed good agreement in terms of airflow obstruction reversibility (kappa 0.60). Conclusion Albuterol vibrating mesh nebulization within a nasal high-flow circuit induces similar bronchodilation to standard facial mask jet nebulization. Beyond pharmacological bronchodilation, nasal high flow by itself may induce small but significant bronchodilation. Electronic supplementary material The online version of this article (10.1186/s13613-018-0473-8) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
- François Reminiac
- Médecine Intensive Réanimation, CHRU de Tours, 2, Bd Tonnellé, 37044, Tours Cedex 9, France.,Centre d'étude des pathologies respiratoires, INSERM U1100, Faculté de médecine, Université de Tours, Tours, France.,Clinique du Mail, La Rochelle, France
| | - Laurent Vecellio
- Centre d'étude des pathologies respiratoires, INSERM U1100, Faculté de médecine, Université de Tours, Tours, France
| | - Laetitia Bodet-Contentin
- Médecine Intensive Réanimation, CHRU de Tours, 2, Bd Tonnellé, 37044, Tours Cedex 9, France.,Centre d'investigation clinique, INSERM CIC 1415, CHRU de Tours, Tours, France.,CRICS-TRIGGERSEP Network, Tours, France
| | - Valérie Gissot
- Centre d'investigation clinique, INSERM CIC 1415, CHRU de Tours, Tours, France
| | - Deborah Le Pennec
- Centre d'étude des pathologies respiratoires, INSERM U1100, Faculté de médecine, Université de Tours, Tours, France
| | - Charlotte Salmon Gandonnière
- Médecine Intensive Réanimation, CHRU de Tours, 2, Bd Tonnellé, 37044, Tours Cedex 9, France.,Centre d'investigation clinique, INSERM CIC 1415, CHRU de Tours, Tours, France.,CRICS-TRIGGERSEP Network, Tours, France
| | - Maria Cabrera
- Centre d'étude des pathologies respiratoires, INSERM U1100, Faculté de médecine, Université de Tours, Tours, France
| | - Pierre-François Dequin
- Médecine Intensive Réanimation, CHRU de Tours, 2, Bd Tonnellé, 37044, Tours Cedex 9, France.,Centre d'étude des pathologies respiratoires, INSERM U1100, Faculté de médecine, Université de Tours, Tours, France.,Centre d'investigation clinique, INSERM CIC 1415, CHRU de Tours, Tours, France.,CRICS-TRIGGERSEP Network, Tours, France
| | - Laurent Plantier
- Centre d'étude des pathologies respiratoires, INSERM U1100, Faculté de médecine, Université de Tours, Tours, France.,Service de pneumologie et d'explorations fonctionnelles respiratoires, CHRU de Tours, Tours, France
| | - Stephan Ehrmann
- Médecine Intensive Réanimation, CHRU de Tours, 2, Bd Tonnellé, 37044, Tours Cedex 9, France. .,Centre d'étude des pathologies respiratoires, INSERM U1100, Faculté de médecine, Université de Tours, Tours, France. .,Centre d'investigation clinique, INSERM CIC 1415, CHRU de Tours, Tours, France. .,CRICS-TRIGGERSEP Network, Tours, France.
| |
Collapse
|
34
|
Farkas D, Hindle M, Longest PW. Efficient Nose-to-Lung Aerosol Delivery with an Inline DPI Requiring Low Actuation Air Volume. Pharm Res 2018; 35:194. [PMID: 30132207 DOI: 10.1007/s11095-018-2473-7] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2018] [Accepted: 08/03/2018] [Indexed: 11/28/2022]
Abstract
PURPOSE To demonstrate efficient aerosol delivery through an in vitro nasal model using a dry powder inhaler (DPI) requiring low actuation air volumes (LV) applied during low-flow nasal cannula (LFNC) therapy. METHODS A previously developed LV-DPI was connected to a LFNC system with 4 mm diameter tubing. System connections and the nasal cannula interface were replaced with streamlined components. To simulate nasal respiration, an in vitro nasal model was connected to a downstream lung simulator that produced either passive or deep nasal respiration. Performance of a commercial mesh nebulizer system was also considered. RESULTS For the optimized system, steady state cannula emitted dose was 75% of the capsule loaded dose. With cyclic nasal breathing, delivery efficiency to the tracheal filter was 53-55% of the loaded dose, which was just under the design target of 60%. Compared with a commercially available mesh nebulizer, the optimal LV-DPI was 40-fold more efficient and 150 times faster in terms of delivering aerosol to the lungs. CONCLUSIONS The optimized LV-DPI system is capable of high efficiency lung delivery of powder aerosols through a challenging nasal cannula interface.
Collapse
Affiliation(s)
- Dale Farkas
- Department of Mechanical and Nuclear Engineering, Virginia Commonwealth University, 401 West Main Street, P.O. Box 843015 Richmond, Virginia, 23284-3015, USA
| | - Michael Hindle
- Department of Pharmaceutics, Virginia Commonwealth University Richmond, Virginia, USA
| | - P Worth Longest
- Department of Mechanical and Nuclear Engineering, Virginia Commonwealth University, 401 West Main Street, P.O. Box 843015 Richmond, Virginia, 23284-3015, USA. .,Department of Pharmaceutics, Virginia Commonwealth University Richmond, Virginia, USA.
| |
Collapse
|
35
|
Bennett G, Joyce M, Sweeney L, MacLoughlin R. In Vitro Determination of the Main Effects in the Design of High-Flow Nasal Therapy Systems with Respect to Aerosol Performance. Pulm Ther 2018; 4:73-86. [PMID: 32026245 PMCID: PMC6967237 DOI: 10.1007/s41030-018-0054-x] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2018] [Indexed: 12/31/2022] Open
Abstract
INTRODUCTION The use of concurrent aerosol delivery during high-flow nasal therapy (HFNT) may be exploited to facilitate the delivery of a variety of prescribed medications for inhalation. Until now, a systematic approach to determine the conditions required to yield an optimal emitted dose has not been reported. The aim of this study was to establish the effects of gas flow rate, input droplet size, and nebulizer position on the amount of aerosol exiting the nasal cannula during HFNT and thus becoming available for inhalation. METHODS Testing was completed according to a factorial statistical design of experiments (DOE) approach. Emitted dose was characterized with a vibrating mesh nebulizer (Aerogen Solo, Aerogen Ltd) for an adult model of HFNT at three clinically relevant gas flow rates, using three nebulizers producing varying input droplet sizes and placed at two different nebulizer positions. RESULTS Increasing the gas flow rate significantly lowered the emitted dose, with a dose of 7.10% obtained at 10 LPM, 2.67% at 25 LPM, and 1.30% at 40 LPM (p < 0.0001). There was a significant difference in emitted dose between nebulizers with different input droplet sizes, with increasing input droplet size associated with a reduced emitted dose (6.11% with an input droplet size of 3.22 µm, 2.76% with 4.05 µm, and 2.38% with 4.88 µm, p = 0.0002, Pearson's r = - 0.2871). In addition, the droplet size exiting the nasal cannula interface was lower than that produced by the aerosol generator for all devices under test. Positioning the nebulizer immediately after the humidification chamber yielded a marginally greater emitted dose (3.79%) than when the nebulizer was placed immediately upstream of the nasal cannula (3.39%). Flow rate, input droplet size, and nebulizer position were at the 0.10 level of significance, indicating that all three factors had significant effects on emitted dose. According to the DOE model, flow rate had the greatest influence on emitted dose, followed by input droplet size and then nebulizer position. CONCLUSION Our findings indicate that in order to optimize the amount of aerosol exiting the nasal cannula interface during HFNT, it is necessary for gas flow rate to be low and the input droplet size to be small, while the nebulizer should be positioned immediately after the humidification chamber. FUNDING Aerogen Limited.
Collapse
Affiliation(s)
- Gavin Bennett
- Aerogen Limited, IDA Business Park, Dangan, Galway, Ireland.
| | - Mary Joyce
- Aerogen Limited, IDA Business Park, Dangan, Galway, Ireland
| | - Louise Sweeney
- Aerogen Limited, IDA Business Park, Dangan, Galway, Ireland
| | | |
Collapse
|
36
|
Ehrmann S. Vibrating Mesh Nebulisers – Can Greater Drug Delivery to the Airways and Lungs Improve Respiratory Outcomes? ACTA ACUST UNITED AC 2018. [DOI: 10.17925/erpd.2018.4.1.33] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
Aerosols are an increasingly important mode of delivery of drugs, particularly bronchodilators, for the treatment of respiratory diseases, notably asthma and chronic obstructive pulmonary disease. The most common type of nebuliser is the jet nebuliser (JN); they have been in use for more than a century but these devices can be cumbersome to use and may sometimes deliver insufficient amounts of drug. A more recent development in aerosol therapy is the vibrating mesh nebuliser (VMN) which is very user friendly and is more efficient than the JNs due to an extremely low residual volume. Scintigraphy images from studies of volunteer subjects using radio-labelled aerosol treatment show that VMN-generated aerosols deliver more drug to patients in a shorter period of time than JN-generated aerosols. Various bench, animal model and small clinical studies have shown that VMNs are more efficient than JNs in drug delivery, potentially improving clinical outcomes. These studies have included various breathing circuits used in mechanical ventilation (MV), non-invasive ventilation, high-flow nasal cannula systems and devices for spontaneously breathing patients. The efficiency of drug delivery was affected by factors including the position of the nebuliser in the circuit and humidity. Some studies have shown potential substantial savings by hospitals in the cost of MV treatments after switching from metered dose inhalers to VMNs. VMNs have also been shown to be effective for the administration of inhaled antibiotics, corticosteroids and other drugs. Larger studies of the effects of VMNs on patient outcomes are needed but they are likely to be an increasingly important means of administering therapies to a burgeoning population with respiratory disease.
Collapse
|
37
|
Bräunlich J, Wirtz H. Oral Versus Nasal High-Flow Bronchodilator Inhalation in Chronic Obstructive Pulmonary Disease. J Aerosol Med Pulm Drug Deliv 2017; 31:248-254. [PMID: 29261402 DOI: 10.1089/jamp.2017.1432] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023] Open
Abstract
BACKGROUND Nasal high flow (NHF) alters breathing patterns, stabilizes fraction of inspired oxygen (FiO2) during respiratory distress, helps to keep up hemostasis in the airways, and washes out the upper airways. Particularly the support of inspiratory flow and decrease in functional dead space are interesting mechanisms of action with regard to aerosol delivery. Several laboratory investigations have studied aerosol delivery via the nasal route by using NHF, whereas clinical benefits are poorly evaluated. METHODS Thirty patients with stable chronic obstructive pulmonary disease Gold D were recruited. In a randomized order, they inhaled a salbutamol 2.5 mg/ipratropium bromide 500 μg solution oral or NHF adapted on the second study day. A jet nebulizer was used as aerosol delivery device. The chosen flow rate was 35 L/min. RESULTS Four patients refused to repeat the procedure, for example, for inconvenience or fear of delayed discharge, and were not included in the intention-to-treat analysis. All remaining patients tolerated both inhalation systems well. Forced vital capacity (FVC), forced expiratory volume in 1 second (FEV1), airway resistance (Rtot), and residual volume (RV) were significantly altered after bronchodilator inhalation with each of the both devices. The two different ways of combined bronchodilator inhalation resulted in very comparable changes in FVC, FEV1, relative 1 second-capacity (FEV1%FVC), Rtot, total lung capacity (TLC), RV, and residual volume expressed as percent of TLC (RV%TLC). However, in between devices, no difference was observed on comparing the postinhalational measurements of FVC, FEV1, Rtot, and RV. CONCLUSIONS We conclude from this proof-of-principle kind of study that inhalation of combined bronchodilators adapted to an NHF device is similarly effective to inhalation with a standard oral aerosol nebulizer. (Clinical Trails NCT02885103).
Collapse
Affiliation(s)
- Jens Bräunlich
- Department of Respiratory Medicine, University of Leipzig , Leipzig, Germany
| | - Hubert Wirtz
- Department of Respiratory Medicine, University of Leipzig , Leipzig, Germany
| |
Collapse
|
38
|
Okuda T, Tang P, Yu J, Finlay WH, Chan HK. Powder aerosol delivery through nasal high-flow system: In vitro feasibility and influence of process conditions. Int J Pharm 2017; 533:187-197. [PMID: 28830783 DOI: 10.1016/j.ijpharm.2017.08.079] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2017] [Revised: 08/02/2017] [Accepted: 08/14/2017] [Indexed: 11/19/2022]
Abstract
We aimed to obtain fundamental information for potential pulmonary delivery of powder aerosols using a clinically-approved nasal high-flow system (AIRVO), with spray-dried mannitol (SD-Man) being a model powder. Compressed air exiting the AIRVO at set 'dispersion' air flow rates dispersed SD-Man loaded in an Osmohaler® into a human nasal airway replica (NAR) coupled downstream to a Next Generation Impactor (NGI) running at specific 'inspiratory' flow rates. Increasing the dispersion flow rate from 30 to 60L/min increased powder deposition in the NAR from 50 to 70% of the emitted dose, while decreased the NGI deposition from 50 to 30% of the emitted dose. The inspiratory flow rate did not affect powder deposition in the NAR and NGI. In contrast, as the inspiratory flow rate was increased from 15 to 40L/min, powder recovery, emitted fraction, and fine particle fraction below 5μm (as aerosol performance indices) were increased from 90, 30 and 5% to 97, 45 and 8% of the loaded dose, respectively. The dispersion flow rate did not change the performance indices. Importantly, heating and humidification of dispersion airflow, loaded doses, and nasal cannula sizes did not greatly affect the aerosol characteristics.
Collapse
Affiliation(s)
- Tomoyuki Okuda
- Advanced Drug Delivery Group, Faculty of Pharmacy, The University of Sydney, Sydney, 2006 NSW, Australia; Faculty of Pharmacy, Meijo University, 150 Yagotoyama, Tempaku-ku, Nagoya 468-8503, Japan.
| | - Patricia Tang
- Advanced Drug Delivery Group, Faculty of Pharmacy, The University of Sydney, Sydney, 2006 NSW, Australia
| | - Jiaqi Yu
- Advanced Drug Delivery Group, Faculty of Pharmacy, The University of Sydney, Sydney, 2006 NSW, Australia
| | - Warren H Finlay
- Department of Mechanical Engineering, University of Alberta, Edmonton, T6G2G8, Canada
| | - Hak-Kim Chan
- Advanced Drug Delivery Group, Faculty of Pharmacy, The University of Sydney, Sydney, 2006 NSW, Australia.
| |
Collapse
|