1
|
Simão AY, Oliveira P, Rosendo LM, Rosado T, Andraus M, Barroso M, Gallardo E. Microextraction by Packed Sorbent as a Clean-up Approach for the Determination of Ketamine and Norketamine in Hair by Gas Chromatography--Tandem Mass Spectrometry. J Anal Toxicol 2023; 47:227-235. [PMID: 36124733 DOI: 10.1093/jat/bkac075] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2022] [Revised: 09/08/2022] [Accepted: 09/16/2022] [Indexed: 11/12/2022] Open
Abstract
The use of new psychoactive substances has been increasing and constitutes a social and public health problem, and hence, toxicological analysis has become of utmost importance for the detection of such substances. In this article, we present the development and full validation of a simple, user and environmentally friendly, cheap and suitable method for the determination of ketamine and its main metabolite norketamine in hair samples. The procedure included using a miniaturized procedure-microextraction by packed sorbent with mixed-mode sorbent-for sample clean-up. Organic solvents use was minimal, and it was possible to obtain a linear method (0.05-10 ng/mg for both analytes). The extraction efficiency ranged from 32 to 61%, which did not impair sensitivity. The method proved to be selective, precise, accurate and suitable for routine analysis for the determination of said compounds in 50-mg hair samples.
Collapse
Affiliation(s)
- A Y Simão
- Centro de Investigação em Ciências da Saúde, Faculdade de Ciências da Saúde da Universidade da Beira Interior (CICS-UBI), Covilhã 6200-506, Portugal
- Laboratório de Fármaco-Toxicologia-UBIMedical, Universidade da Beira Interior, Covilhã 6200-000, Portugal
| | - P Oliveira
- Centro de Investigação em Ciências da Saúde, Faculdade de Ciências da Saúde da Universidade da Beira Interior (CICS-UBI), Covilhã 6200-506, Portugal
- Laboratório de Fármaco-Toxicologia-UBIMedical, Universidade da Beira Interior, Covilhã 6200-000, Portugal
| | - L M Rosendo
- Centro de Investigação em Ciências da Saúde, Faculdade de Ciências da Saúde da Universidade da Beira Interior (CICS-UBI), Covilhã 6200-506, Portugal
- Laboratório de Fármaco-Toxicologia-UBIMedical, Universidade da Beira Interior, Covilhã 6200-000, Portugal
| | - T Rosado
- Centro de Investigação em Ciências da Saúde, Faculdade de Ciências da Saúde da Universidade da Beira Interior (CICS-UBI), Covilhã 6200-506, Portugal
- Laboratório de Fármaco-Toxicologia-UBIMedical, Universidade da Beira Interior, Covilhã 6200-000, Portugal
| | - M Andraus
- Chromatox/Dasa Laboratory Ltda, Sumaré, São Paulo-SP 01259-000, Brazil
| | - M Barroso
- Serviço de Química e Toxicologia Forenses, Instituto Nacional de Medicina Legal e Ciências Forenses-Delegação do Sul, Lisboa 1169-201, Portugal
| | - E Gallardo
- Centro de Investigação em Ciências da Saúde, Faculdade de Ciências da Saúde da Universidade da Beira Interior (CICS-UBI), Covilhã 6200-506, Portugal
- Laboratório de Fármaco-Toxicologia-UBIMedical, Universidade da Beira Interior, Covilhã 6200-000, Portugal
| |
Collapse
|
2
|
Paneru S, Kumar D. A Novel Electrochemical Biosensor Based on Polyaniline-Embedded Copper Oxide Nanoparticles for High-Sensitive Paraoxon-Ethyl (PE) Detection. Appl Biochem Biotechnol 2023:10.1007/s12010-023-04350-y. [PMID: 36701097 DOI: 10.1007/s12010-023-04350-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/10/2023] [Indexed: 01/27/2023]
Abstract
This paper proposes a fabrication of a hyper-sensitive amperometric biosensor for paraoxon-ethyl (PE) detection. In this developed biosensor, polyaniline (PANI) and copper oxide (CuO)-based nanocomposite is used as a sensing platform. The homogeneous distribution of CuO onto the PANI matrix enhances the surface area and conductivity of the nanocomposite. Additionally, the PANI produces a compatible environment for enzyme immobilization, which further enhances the rate of electron transfer. For biosensor fabrication, the nanocomposite is deposited electrophoretically onto the ITO glass substrate and immobilization of acetylcholinesterase (AChE) enzyme is conducted onto the fabricated electrode surface. The results validate good reproducibility, good stability, and high selectivity of the fabricated biosensor (AChE/PANI@CuO/ITO). The inhibition rate of paraoxon-ethyl (PE) is recorded in the concentration range of 1-200 nM with a low limit of detection of 0.096 nM or 96 pM. The sensitivity of the developed biosensor is found to be 49.86 µA(nM)-1. The developed biosensor is further successfully accomplished for the detection of PE in real samples like rice and pulse.
Collapse
Affiliation(s)
- Saroj Paneru
- Department of Applied Chemistry, Delhi Technological University, Delhi, 110042, India
| | - Devendra Kumar
- Department of Applied Chemistry, Delhi Technological University, Delhi, 110042, India.
| |
Collapse
|
3
|
Rosendo LM, Rosado T, Oliveira P, Simão AY, Margalho C, Costa S, Passarinha LA, Barroso M, Gallardo E. The Determination of Cannabinoids in Urine Samples Using Microextraction by Packed Sorbent and Gas Chromatography-Mass Spectrometry. Molecules 2022; 27:molecules27175503. [PMID: 36080271 PMCID: PMC9457599 DOI: 10.3390/molecules27175503] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2022] [Revised: 08/24/2022] [Accepted: 08/25/2022] [Indexed: 11/16/2022] Open
Abstract
Cannabis is the most consumed illicit drug worldwide, and its legal status is a source of concern. This study proposes a rapid procedure for the simultaneous quantification of Δ9-tetrahydrocannabinol (THC), 11-hydroxy-Δ9-tetrahydrocannabinol (11-OH-THC), 11-nor-9-carboxy-Δ9-tetrahydrocannabinol (THC-COOH), cannabidiol (CBD), and cannabinol (CBN) in urine samples. Microextraction by packed sorbent (MEPS) was used to pre-concentrate the analytes, which were detected by gas chromatography–mass spectrometry. The procedure was previously optimized, and the final conditions were: conditioning with 50 µL methanol and 50 µL of water, sample load with two draw–eject cycles, and washing with 310 µL of 0.1% formic acid in water with 5% isopropanol; the elution was made with 35 µL of 0.1% ammonium hydroxide in methanol. This fast extraction procedure allowed quantification in the ranges of 1–400 ng/mL for THC and CBD, 5–400 ng/mL for CBN and 11-OH-THC, and 10–400 ng/mL for THC-COOH with coefficients of determination higher than 0.99. The limits of quantification and detection were between 1 and 10 ng/mL using 0.25 mL of sample. The extraction efficiencies varied between 26 and 85%. This analytical method is the first allowing the for determination of cannabinoids in urine samples using MEPS, a fast, simple, and low-cost alternative to conventional techniques.
Collapse
Affiliation(s)
- Luana M. Rosendo
- Centro de Investigação em Ciências da Saúde, Universidade da Beira Interior (CICS-UBI), Av. Infante D. Henrique, 6201-506 Covilhã, Portugal
| | - Tiago Rosado
- Centro de Investigação em Ciências da Saúde, Universidade da Beira Interior (CICS-UBI), Av. Infante D. Henrique, 6201-506 Covilhã, Portugal
- Laboratório de Fármaco-Toxicologia, Ubimedical, Universidade da Beira Interior, Estrada Municipal 506, 6200-284 Covilhã, Portugal
| | - Patrik Oliveira
- Centro de Investigação em Ciências da Saúde, Universidade da Beira Interior (CICS-UBI), Av. Infante D. Henrique, 6201-506 Covilhã, Portugal
| | - Ana Y. Simão
- Centro de Investigação em Ciências da Saúde, Universidade da Beira Interior (CICS-UBI), Av. Infante D. Henrique, 6201-506 Covilhã, Portugal
- Laboratório de Fármaco-Toxicologia, Ubimedical, Universidade da Beira Interior, Estrada Municipal 506, 6200-284 Covilhã, Portugal
| | - Cláudia Margalho
- Serviço de Química e Toxicologia Forenses, Instituto de Medicina Legal e Ciências Forenses-Delegação do Centro, 3000-213 Coimbra, Portugal
| | - Suzel Costa
- Serviço de Química e Toxicologia Forenses, Instituto de Medicina Legal e Ciências Forenses-Delegação do Sul, 1169-201 Lisboa, Portugal
| | - Luís A. Passarinha
- Centro de Investigação em Ciências da Saúde, Universidade da Beira Interior (CICS-UBI), Av. Infante D. Henrique, 6201-506 Covilhã, Portugal
- Laboratório de Fármaco-Toxicologia, Ubimedical, Universidade da Beira Interior, Estrada Municipal 506, 6200-284 Covilhã, Portugal
- UCIBIO-Apllied Molecular Bioesciences Unit, Departamento de Química, Faculdade de Ciências e Tecnologia, Universidade NOVA de Lisboa, 1099-085 Caparica, Portugal
- Associate Laboratory i4HB-Institute for Health and Bioeconomy, NOVA School of Science and Technology, Universidade NOVA, 2819-516 Caparica, Portugal
- Correspondence: (L.A.P.); (M.B.); (E.G.); Tel.: +351-27-532-9002 (L.A.P.); +351-21-881-1800 (M.B.); +351-27-532-9002 (E.G.)
| | - Mário Barroso
- Serviço de Química e Toxicologia Forenses, Instituto de Medicina Legal e Ciências Forenses-Delegação do Sul, 1169-201 Lisboa, Portugal
- Correspondence: (L.A.P.); (M.B.); (E.G.); Tel.: +351-27-532-9002 (L.A.P.); +351-21-881-1800 (M.B.); +351-27-532-9002 (E.G.)
| | - Eugenia Gallardo
- Centro de Investigação em Ciências da Saúde, Universidade da Beira Interior (CICS-UBI), Av. Infante D. Henrique, 6201-506 Covilhã, Portugal
- Laboratório de Fármaco-Toxicologia, Ubimedical, Universidade da Beira Interior, Estrada Municipal 506, 6200-284 Covilhã, Portugal
- Correspondence: (L.A.P.); (M.B.); (E.G.); Tel.: +351-27-532-9002 (L.A.P.); +351-21-881-1800 (M.B.); +351-27-532-9002 (E.G.)
| |
Collapse
|
4
|
Tao S, Guo Y, Wang S, Xu F, Zhou X, Guo Q. A sensitive and stable acetylcholinesterase biosensor with TiO 2 nanoparticles anchored on graphitic carbon nanofibers for determination of organophosphate pesticides. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2022; 14:2396-2404. [PMID: 35666469 DOI: 10.1039/d2ay00351a] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Electrode materials play a central role in assembling biosensors. In this work, a titanium dioxide nanoparticle loaded graphitized carbon nanofiber (TiO2/GNF) composite is prepared for the sensitive detection of organophosphorus pesticide residues (OPs). The TiO2/GNF composite with superior conductivity, catalytic activity and biocompatibility offers an extremely hydrophilic surface for the effective immobilization of acetylcholinesterase (AChE). Furthermore, the Ti atoms of TiO2/GNFs could coordinate with AChE to improve its stability, and TiO2 has a strong adsorption on OPs. The developed AChE/TiO2/GNFs/GCE biosensor showed a high affinity to acetylthiocholine chloride (ATCh) and could catalyze the hydrolysis of ATCh with an apparent Michaelis-Menten constant (Km) of 50 μM. The constructed AChE/TiO2/GNFs/GCE biosensor exhibits a wide detection linear range (1.0 × 10-13 M to 1.0 × 10-8 M) with a low detection limit (3.3 fM) for paraoxon determination (a model of OPs). In addition, the developed biosensor possesses remarkable anti-interference, acceptable reproducibility and good long-term stability, and is successfully used for the determination of OPs in lake water, providing a new strategy for the analysis of OPs in ecological environments.
Collapse
Affiliation(s)
- Shihan Tao
- Department of Chemistry and Chemical Engineering, Jiangxi Normal University, Nanchang, Jiangxi 330022, China.
| | - Yuan Guo
- Department of Chemistry and Chemical Engineering, Jiangxi Normal University, Nanchang, Jiangxi 330022, China.
| | - Shuqin Wang
- Department of Chemistry and Chemical Engineering, Jiangxi Normal University, Nanchang, Jiangxi 330022, China.
| | - Fangting Xu
- Department of Chemistry and Chemical Engineering, Jiangxi Normal University, Nanchang, Jiangxi 330022, China.
| | - Xiaoping Zhou
- Department of Chemistry and Chemical Engineering, Jiangxi Normal University, Nanchang, Jiangxi 330022, China.
| | - Qiaohui Guo
- Department of Chemistry and Chemical Engineering, Jiangxi Normal University, Nanchang, Jiangxi 330022, China.
| |
Collapse
|
5
|
Kumar D, Sinha SN, Ungarala R, Mungamuri SK, Kasturi V. A simple and sensitive liquid chromatography–tandem mass spectrometry method for quantification of multi‐residual pesticides in blood. SEPARATION SCIENCE PLUS 2022. [DOI: 10.1002/sscp.202100067] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Affiliation(s)
- Dileshwar Kumar
- Division of Food Safety Indian Council of Medical Research ‐ National Institute of Nutrition Jamai‐Osmania Hyderabad Telangana 500007 India
| | - Sukesh Narayan Sinha
- Division of Food Safety Indian Council of Medical Research ‐ National Institute of Nutrition Jamai‐Osmania Hyderabad Telangana 500007 India
| | - Ramakrishna Ungarala
- Division of Food Safety Indian Council of Medical Research ‐ National Institute of Nutrition Jamai‐Osmania Hyderabad Telangana 500007 India
| | - Sathish Kumar Mungamuri
- Division of Food Safety Indian Council of Medical Research ‐ National Institute of Nutrition Jamai‐Osmania Hyderabad Telangana 500007 India
| | - Vasudev Kasturi
- Division of Food Safety Indian Council of Medical Research ‐ National Institute of Nutrition Jamai‐Osmania Hyderabad Telangana 500007 India
| |
Collapse
|
6
|
Bhattu M, Kathuria D, Billing BK, Verma M. Chromatographic techniques for the analysis of organophosphate pesticides with their extraction approach: a review (2015-2020). ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2022; 14:322-358. [PMID: 34994766 DOI: 10.1039/d1ay01404h] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
In agriculture, a wide range of OPPs has been employed to boost crop yield, quality, and storage life. However, due to the ever-increasing population and rapid urbanization, pesticide use has surged in recent years. These compounds are exceedingly poisonous to humans, and despite the fact that specific legislation prohibits their use, the frequency of toxic and/or fatal incidents, as well as current statistics, suggest that they are currently accessible. As a result, determining the exposure to these substances as well as their detection (and that of their metabolites) in different types of exposed samples has become a hot issue in terms of quality and safety concerns. However, developing tools for the evaluation of these substances is a critical challenge for laboratories. Various chromatographic-based methods reported in the period of 2015-2020 have been developed, which are summarized and critically reviewed in this article, including the extraction of the target OPPs from different kinds of matrices. A comparison among the extraction and analysis techniques has been made in the current review article.
Collapse
Affiliation(s)
- Monika Bhattu
- University Centre for Research and Development, Chandigarh University, Gharuan, Punjab 140413, India. niperdeepika12@gmail
| | - Deepika Kathuria
- University Centre for Research and Development, Chandigarh University, Gharuan, Punjab 140413, India. niperdeepika12@gmail
| | - Beant Kaur Billing
- University Centre for Research and Development, Chandigarh University, Gharuan, Punjab 140413, India. niperdeepika12@gmail
| | - Meenakshi Verma
- University Centre for Research and Development, Chandigarh University, Gharuan, Punjab 140413, India. niperdeepika12@gmail
| |
Collapse
|
7
|
Tang J, Liu L, Gao S, Qin J, Liu X, Tang D. A portable thermal detection method based on the target responsive hydrogel mediated self-heating of a warming pad. Chem Commun (Camb) 2021; 57:9862-9865. [PMID: 34490870 DOI: 10.1039/d1cc03733a] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
A simple thermal aptasensing platform was devised for the sensitive detection of organophosphate pesticides (using malathion as a model target) based on the efficient self-heating reaction of a warming pad with a switchable target responsive enzyme-encapsulated three-dimensional (3D) DNA hydrogel using a portable thermometer as a signal readout in this work. The existence of the target malathion would open the catalase-3D network and lots of catalase was released from the hydrogel, which could efficiently convert H2O2 to an O2 molecule. The product O2 is the critical condition for the self-heating of the warming pad. Thereafter, the temperature was enhanced with the increasing amount of O2. The strategy displays outstanding specificity, reproducibility and stability. Moreover, this method can be easily extended to monitor other molecules using different aptamer sequences in practical applications.
Collapse
Affiliation(s)
- Juan Tang
- Key Laboratory for Green Chemistry of Jiangxi Province, Key Laboratory of Functional Small Molecules for Ministry of Education, Jiangxi Normal University, Nanchang, 330022, P. R. China.
| | - Liping Liu
- Key Laboratory for Green Chemistry of Jiangxi Province, Key Laboratory of Functional Small Molecules for Ministry of Education, Jiangxi Normal University, Nanchang, 330022, P. R. China.
| | - Shan Gao
- Key Laboratory for Green Chemistry of Jiangxi Province, Key Laboratory of Functional Small Molecules for Ministry of Education, Jiangxi Normal University, Nanchang, 330022, P. R. China.
| | - Jiao Qin
- Key Laboratory for Green Chemistry of Jiangxi Province, Key Laboratory of Functional Small Molecules for Ministry of Education, Jiangxi Normal University, Nanchang, 330022, P. R. China.
| | - Xiaoxuan Liu
- Key Laboratory for Green Chemistry of Jiangxi Province, Key Laboratory of Functional Small Molecules for Ministry of Education, Jiangxi Normal University, Nanchang, 330022, P. R. China.
| | - Dianping Tang
- Key Laboratory of Analysis and Detection for Food Safety (Ministry of Education of China and Fujian Province), Department of Chemistry, Fuzhou University, Fuzhou, 350108, P. R. China
| |
Collapse
|
8
|
Experimental central composite design-based dispersive liquid-liquid microextraction for HPLC-DAD determination of diazinon in human urine samples: method development and validation. Arh Hig Rada Toksikol 2021; 71:48-55. [PMID: 32597136 PMCID: PMC7837239 DOI: 10.2478/aiht-2020-71-3292] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2019] [Accepted: 02/01/2020] [Indexed: 11/21/2022] Open
Abstract
Diazinon poisoning is an important issue in occupational, clinical, and forensic toxicology. While sensitive and specific enough to analyse diazinon in biological samples, current methods are time-consuming and too expensive for routine analysis. The aim of this study was therefore to design and validate a simple dispersive liquid-liquid microextraction (DLLME) for the preparation of urine samples to be analysed for diazinon with high performance liquid chromatography with diode-array detector (HPLC-DAD) to establish diazinon exposure and poisoning. To do that, we first identified critical parameters (type and volume of extraction and disperser solvents, pH, surfactant, and salt concentrations) in preliminary experiments and then used central composite design to determine the best experimental conditions for DLLME-HPLC-DAD. For DLLME they were 800 µL of methanol (disperser solvent) and 310 µL of toluene (extraction solvent) injected to the urine sample rapidly via a syringe. The sample was injected into a HPLC-DAD (C18 column, 250×4.6 mm, 5 μm), and the mobile phase was a mixture of acetonitrile and buffer (63:37 v/v, pH 3.2; flow rate: 1 mL/ min). Standard calibration curves for diazinon were linear with the concentration range of 0.5-4 µg/mL, yielding a regression equation Y=0.254X+0.006 with a correlation coefficient of 0.993. The limit of detection and limit of quantification for diazinon were 0.15 µg/mL and 0.45 µg/mL, respectively. The proposed method was accurate, precise, sensitive, and linear over a wide range of diazinon concentrations in urine samples. This method can be employed for diazinon analysis in routine clinical and forensic toxicology settings.
Collapse
|
9
|
Jordan-Sinisterra M, Lanças FM. Microextraction by packed sorbent of selected pesticides in coffee samples employing ionic liquids supported on graphene nanosheets as extraction phase. Anal Bioanal Chem 2021; 414:413-423. [PMID: 33763748 DOI: 10.1007/s00216-021-03245-3] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2020] [Revised: 02/03/2021] [Accepted: 02/19/2021] [Indexed: 11/28/2022]
Abstract
This paper describes the synthesis, characterization, and use of ionic liquids supported on silica, functionalized with graphene oxide through covalent bonding (ILz/Si@GO), as sorbents for microextraction by packed sorbent (MEPS). Seven selected pesticides (diazinon, heptachlor, aldrin, endrin, dieldrin, endosulfan, and methoxychlor), used for the prevention of pests in coffee crops, and endosulfan sulfate-an endosulfan metabolite-were selected for this study as model compounds for evaluating the sorbent performance of the synthesized materials in the MEPS device. The cycles of each of the stages were previously optimized through univariate experiments to carry out the extraction. The ILz/Si@GO phase was compared to other sorbents used in MEPS (GO, DVB-MMA, C4/SiO2, C8/SiO2, ILz/SiO2, and bare silica) and also with graphene functionalized through other methodologies, where ILz/Si@GO showed the best results. The material was characterized using a range of techniques. The selectivity of the sorbent material and its adsorption capacity were evaluated by gas chromatography coupled with tandem mass spectrometry. The precision and accuracy of the method showed a relative standard deviation lower than 10% and recoveries from 35 to 97%. Finally, the proposed method was employed for the determination of pesticide residues in coffee samples.
Collapse
Affiliation(s)
- Marcela Jordan-Sinisterra
- Institute of Chemistry of São Carlos, University of São Paulo, Av. Trabalhador Saocarlense 400, São Carlos, SP, 13560-970, Brazil
| | - Fernando Mauro Lanças
- Institute of Chemistry of São Carlos, University of São Paulo, Av. Trabalhador Saocarlense 400, São Carlos, SP, 13560-970, Brazil.
| |
Collapse
|
10
|
WEI J, QIN M, YANG J, YANG L. [Research progress of microextraction by packed sorbent and its application in microvolume sample extraction]. Se Pu 2021; 39:219-228. [PMID: 34227304 PMCID: PMC9403807 DOI: 10.3724/sp.j.1123.2020.04024] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2020] [Indexed: 11/30/2022] Open
Abstract
Microextraction is a rapidly developing sample preparation technology in the field of analytical chemistry, which is seeing widespread application. Accurate sample preparation can not only save time but also improve the efficiency of analysis, determination, and data quality. At present, sample pretreatment methods must be rapid, allow for miniaturization, automation, and convenient online connection with analytical instruments. To meet the requirements of green analytical methods and improve the extraction efficiency, microextraction techniques have been introduced as suitable replacements to conventional sample preparation and extraction methods. Microextraction using a packed sorbent (MEPS) is a new type of sample preparation technology. The MEPS equipment was prepared using microsyringe with a volume of 50-500 μL, including MEPS syringes and MEPS adsorption beds (barrel insert and needle, BIN), which is essentially similar to a miniaturized solid phase extraction device. The BIN contains the adsorbent and is built into the syringe needle. A typical MEPS extraction procedure involves repeatedly pumping the sample solution in two directions (up and down) through the adsorbent multiple times in the MEPS syringe. The specific operation course of MEPS includes conditioning, loading, washing, elution, and introduction into the analysis instrument. The conditioning process is adopted to infiltrate the dry sorbent and remove bubbles between the filler particles. The adsorption process is accomplished by pulling the liquid plunger of the syringe so that the sample flows through the adsorbent in both directions multiple times. The washing process involves rinsing the sorbent to remove unwanted components after the analyte is retained. The elution process involves the use of an eluent to ensure that the sample flows through the adsorbent in both directions multiple times, so that elution can be realized by the pumping-pushing action. The target analyte is eluted with the eluent, which can be directly used for chromatographic analysis. However, when processing complex biological matrix samples by MEPS, pretreatment steps such as dilution of the sample and removal of proteins are commonly required. At present, the operation modes of the MEPS equipment are classified into three types: manual, semi-automated, and fully automated. This increase in the degree of automation is highly conducive to processing extremely low or extremely high sample volumes. Critical factors affecting the MEPS performance have been investigated in this study. The conditions for MEPS optimization are the operating process parameters, including sample flow rate, sample volume, number of sample extraction cycles, type and volume of the adsorbent, and elution solvents. It is also necessary to consider the effect of the sample matrix on the performance of MEPS. The MEPS sorbent should be cleaned by a solvent to eliminate carryover and reuse. The sorbent is a core aspect of MEPS. Several types of commercial and non-commercial sorbents have been used in MEPS. Commercial sorbents include silica-based sorbents such as unmodified silica (SIL), C2, C8, and C18. Unmodified silicon-based silica is a normal phase adsorption material, which is highly polar and can be used to retain polar analytes. C18, C8, and C2 materials are suitable for reversed-phase adsorption, while SCX, SAX, APS, and M1 (C8+SCX) adsorbents are suitable for the mixed-mode and ion-exchange modes. Noncommercial sorbents include molecularly imprinted materials, restricted-access molecularly imprinted materials, graphitized carbon, conductive polymer materials, modified silicon materials, and covalent-organic framework materials. The performance of MEPS has recently been illustrated by online with LC-MS and GC-MS assays for the analysis of biological matrices, environmental samples, and food samples. Pretreatment in MEPS protocols includes dilution, protein precipitation, and centrifugation in biological fluid matrices. Because of the small sample size, fast operation, etc., MEPS is expected to be more widely used in the analysis of bio-matrix samples. MEPS devices could also play an important role in field pretreatment and analysis.
Collapse
Affiliation(s)
- Jianan WEI
- 国民核生化灾害防护国家重点实验室, 北京 102205
- State key Laboratory of Nuclear, Biological and Chemical Protection for Civilian, Beijing 102205, China
| | - Molin QIN
- 国民核生化灾害防护国家重点实验室, 北京 102205
- State key Laboratory of Nuclear, Biological and Chemical Protection for Civilian, Beijing 102205, China
| | - Junchao YANG
- 国民核生化灾害防护国家重点实验室, 北京 102205
- State key Laboratory of Nuclear, Biological and Chemical Protection for Civilian, Beijing 102205, China
| | - Liu YANG
- 国民核生化灾害防护国家重点实验室, 北京 102205
- State key Laboratory of Nuclear, Biological and Chemical Protection for Civilian, Beijing 102205, China
| |
Collapse
|
11
|
Li D, Zhang Y, Guo Q, Sun X, Zhang H, Wang S, Birech Z, Hu J. An efficient LSPR method to quantitatively detect dimethoate: Development, characterization and evaluation. PLoS One 2020; 15:e0239632. [PMID: 32970749 PMCID: PMC7514021 DOI: 10.1371/journal.pone.0239632] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2020] [Accepted: 09/09/2020] [Indexed: 11/18/2022] Open
Abstract
In recent years, there has been growing concern among consumers about pesticide contamination in fruits. Therefore, rapid, reliable, and consistent detection methods for OPPs, especially dimethoate, are crucially needed. The existing quantitative methods for detecting dimethoate are not suitable for rapid measuring system such as the dimethoate samples from two channels. Hence this paper examines the utilization of a dual-channel system for utilize the absorption variations of the Localized Surface Plasmon Resonance (LSPR) bands of gold nanoparticles (AuNPs) were investigate for detection of dimethoate. Under optimized conditions, the relationship between concentrations of dimethoate and absorbance ratios (A(520)/A(640)) was linearly found in the concentration range of 10–100 nM. Result from the experiment shows that both channels exhibit a linear correlation coefficient as high as 0.97 and a limit of detection (LOD) as low as 5.5 nM. This LSPR detection system was characterized by testing the dimethoate in apple samples and the recovery rates were found to be in the range of 85.90% to 107.37%. The proposed dual-channel LSPR system for detecting dimethoate creating a new approach for detecting organophosphate insecticide in agricultural fields. It could lay the foundation for designing a high-throughput analysis of the insecticides using a wavelength division multiplexing switch (WDMS).
Collapse
Affiliation(s)
- Dongxian Li
- Department of Electrical Engineering, Henan Agricultural University, Zhengzhou, China
- Henan International Joint Laboratory of Laser Technology in Agriculture Sciences, Zhengzhou, China
| | - Yanyan Zhang
- Department of Electrical Engineering, Henan Agricultural University, Zhengzhou, China
- Henan International Joint Laboratory of Laser Technology in Agriculture Sciences, Zhengzhou, China
| | - Qingqian Guo
- Department of Electrical Engineering, Henan Agricultural University, Zhengzhou, China
- Henan International Joint Laboratory of Laser Technology in Agriculture Sciences, Zhengzhou, China
| | | | - Hao Zhang
- Department of Electrical Engineering, Henan Agricultural University, Zhengzhou, China
- Henan International Joint Laboratory of Laser Technology in Agriculture Sciences, Zhengzhou, China
| | - Shun Wang
- College of Science, Henan Agricultural University, Zhengzhou, China
| | - Zephania Birech
- Department of Physics, University of Nairobi, Nairobi, Kenya
| | - Jiandong Hu
- Department of Electrical Engineering, Henan Agricultural University, Zhengzhou, China
- Henan International Joint Laboratory of Laser Technology in Agriculture Sciences, Zhengzhou, China
- State Key Laboratory of Wheat and Maize Crop Science, Zhengzhou, China
- * E-mail:
| |
Collapse
|
12
|
Marrubini G, Dugheri S, Cappelli G, Arcangeli G, Mucci N, Appelblad P, Melzi C, Speltini A. Experimental designs for solid-phase microextraction method development in bioanalysis: A review. Anal Chim Acta 2020; 1119:77-100. [DOI: 10.1016/j.aca.2020.04.012] [Citation(s) in RCA: 27] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2019] [Revised: 04/03/2020] [Accepted: 04/04/2020] [Indexed: 12/28/2022]
|
13
|
Chan WS, Wong GF, Hung CW, Wong YN, Fung KM, Lee WK, Dao KL, Leung CW, Lo KM, Lee WM, Cheung BKK. Interpol review of toxicology 2016-2019. Forensic Sci Int Synerg 2020; 2:563-607. [PMID: 33385147 PMCID: PMC7770452 DOI: 10.1016/j.fsisyn.2020.01.018] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2020] [Accepted: 01/23/2020] [Indexed: 12/13/2022]
Abstract
This review paper covers the forensic-relevant literature in toxicology from 2016 to 2019 as a part of the 19th Interpol International Forensic Science Managers Symposium. The review papers are also available at the Interpol website at: https://www.interpol.int/content/download/14458/file/Interpol%20Review%20.Papers%202019.pdf.
Collapse
|
14
|
Application of zirconium-based metal–organic frameworks for micro-extraction by packed sorbent of urinary trans, trans-muconic acid. JOURNAL OF THE IRANIAN CHEMICAL SOCIETY 2020. [DOI: 10.1007/s13738-020-01930-1] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
|
15
|
Microextraction approaches for bioanalytical applications: An overview. J Chromatogr A 2019; 1616:460790. [PMID: 31892411 DOI: 10.1016/j.chroma.2019.460790] [Citation(s) in RCA: 42] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2019] [Revised: 12/12/2019] [Accepted: 12/13/2019] [Indexed: 12/18/2022]
Abstract
Biological samples are usually complex matrices due to the presence of proteins, salts and a variety of organic compounds with chemical properties similar to those of the target analytes. Therefore, sample preparation is often mandatory in order to isolate the analytes from troublesome matrices before instrumental analysis. Because the number of samples in drug development, doping analysis, forensic science, toxicological analysis, and preclinical and clinical assays is steadily increasing, novel high throughput sample preparation approaches are calling for. The key factors in this development are the miniaturization and the automation of the sample preparation approaches so as to cope with most of the twelve principles of green chemistry. In this review, recent trends in sample preparation and novel strategies will be discussed in detail with particular focus on sorptive and liquid-phase microextraction in bioanalysis. The actual applicability of selective sorbents is also considered. Additionally, the role of 3D printing in microextraction for bioanalytical methods will be pinpointed.
Collapse
|
16
|
An acetylcholinesterase biosensor based on doping Au nanorod@SiO2 nanoparticles into TiO2-chitosan hydrogel for detection of organophosphate pesticides. Biosens Bioelectron 2019; 141:111452. [DOI: 10.1016/j.bios.2019.111452] [Citation(s) in RCA: 55] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2019] [Revised: 06/18/2019] [Accepted: 06/19/2019] [Indexed: 11/23/2022]
|
17
|
Organophosphorus pesticide determination in biological specimens: bioanalytical and toxicological aspects. Int J Legal Med 2019; 133:1763-1784. [DOI: 10.1007/s00414-019-02119-9] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2019] [Accepted: 07/02/2019] [Indexed: 12/12/2022]
|
18
|
Zhang P, Sun T, Rong S, Zeng D, Yu H, Zhang Z, Chang D, Pan H. A sensitive amperometric AChE-biosensor for organophosphate pesticides detection based on conjugated polymer and Ag-rGO-NH2 nanocomposite. Bioelectrochemistry 2019; 127:163-170. [DOI: 10.1016/j.bioelechem.2019.02.003] [Citation(s) in RCA: 49] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2018] [Revised: 02/04/2019] [Accepted: 02/04/2019] [Indexed: 01/28/2023]
|
19
|
Rosado T, Barroso M, Vieira DN, Gallardo E. Determination of Selected Opiates in Hair Samples Using Microextraction by Packed Sorbent: A New Approach for Sample Clean-up. J Anal Toxicol 2019; 43:465-476. [DOI: 10.1093/jat/bkz029] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2018] [Revised: 02/07/2019] [Accepted: 04/05/2019] [Indexed: 12/12/2022] Open
Abstract
Abstract
In this article the development and validation of an analytical method using microextraction by packed sorbent (MEPS) to determine tramadol (TRM), codeine (COD), morphine (MOR), 6-acetylcodeine (6-AC), 6-monoacetylmorphine (6-MAM) and fentanyl (FNT) in hair samples by gas chromatography coupled to tandem mass spectrometry (GC–MS-MS) is presented. The MEPS used a mixed mode sorbent, and the steps for sample cleanup were conditioning (three cycles of 250 μL of methanol and three cycles of 250 μL formic acid 2%); sample load (15 cycles of 150 μL); wash (150 μL of 3.36% formic acid); and elution (eight cycles of 100 μL of ammonium hydroxide 2.36% (in methanol)). Linearity was obtained from the lower limit of quantitation (LLOQ) up to 5 ng/mg, with all target compounds revealing determination coefficients >0.99. The LLOQs achieved were 0.01 ng/mg for TRM, COD and 6-AC, and 0.025 ng/mg for MOR, 6-MAM and FNT. The recoveries ranged from 74 to 90% (TRM), 51 to 59% (COD), 22 to 36% (MOR), 69 to 99% (6-AC), 53 to 61% (6-MAM) and 75 to 86% (FNT). Precision and accuracy revealed coefficients of variation typically below 15% and relative errors within a ±15% interval, respectively. This new approach has proven to be an excellent alternative to classic procedures, reducing the volumes of organic solvents required.
Collapse
Affiliation(s)
- Tiago Rosado
- Centro de Investigação em Ciências da Saúde, Faculdade de Ciências da Saúde da Universidade da Beira Interior (CICS-UBI), Av. Infante D. Henrique, 6201-556 Covilhã, Portugal
- Laboratório de Fármaco-Toxicologia-UBIMedical, Universidade da Beira Interior, EM506, 6201-556 Covilhã, Portugal
| | - Mário Barroso
- Instituto Nacional de Medicina Legal e Ciências Forenses—Delegação do Sul, Rua Manuel Bento de Sousa, 3, 1169-201 Lisboa, Portugal
| | - Duarte Nuno Vieira
- Faculdade de Medicina, Universidade de Coimbra, Azinhaga de Santa Comba, Celas, 3000-548 Coimbra, Portugal
| | - Eugenia Gallardo
- Centro de Investigação em Ciências da Saúde, Faculdade de Ciências da Saúde da Universidade da Beira Interior (CICS-UBI), Av. Infante D. Henrique, 6201-556 Covilhã, Portugal
- Laboratório de Fármaco-Toxicologia-UBIMedical, Universidade da Beira Interior, EM506, 6201-556 Covilhã, Portugal
| |
Collapse
|
20
|
Pereira JAM, Gonçalves J, Porto-Figueira P, Figueira JA, Alves V, Perestrelo R, Medina S, Câmara JS. Current trends on microextraction by packed sorbent – fundamentals, application fields, innovative improvements and future applications. Analyst 2019; 144:5048-5074. [DOI: 10.1039/c8an02464b] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
MEPS, the acronym of microextraction by packed sorbent, is a simple, fast and user- and environmentally-friendly miniaturization of the popular solid-phase extraction technique (SPE).
Collapse
Affiliation(s)
- Jorge A. M. Pereira
- CQM – Centro de Química da Madeira
- Universidade da Madeira
- 9020-105 Funchal
- Portugal
| | - João Gonçalves
- CQM – Centro de Química da Madeira
- Universidade da Madeira
- 9020-105 Funchal
- Portugal
| | | | - José A. Figueira
- CQM – Centro de Química da Madeira
- Universidade da Madeira
- 9020-105 Funchal
- Portugal
| | - Vera Alves
- CQM – Centro de Química da Madeira
- Universidade da Madeira
- 9020-105 Funchal
- Portugal
| | - Rosa Perestrelo
- CQM – Centro de Química da Madeira
- Universidade da Madeira
- 9020-105 Funchal
- Portugal
| | - Sonia Medina
- CQM – Centro de Química da Madeira
- Universidade da Madeira
- 9020-105 Funchal
- Portugal
| | - José S. Câmara
- CQM – Centro de Química da Madeira
- Universidade da Madeira
- 9020-105 Funchal
- Portugal
- Faculdade de Ciências Exatas e da Engenharia
| |
Collapse
|